WorldWideScience
1

Characterization of nuclear fuels by ICP mass-spectrometric techniques  

British Library Electronic Table of Contents (United Kingdom)

Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...

2008-01-01

2

State of the Art Laser Induced Breakdown Spectroscopy  

International Nuclear Information System (INIS)

Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the ...

3

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

4

DETERMINATION OF 237NP AND PU ISOTOPES IN LARGE SOIL SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY  

Energy Technology Data Exchange (ETDEWEB)

A new method for the determination of {sup 237}Np and Pu isotopes in large soil samples has been developed that provides enhanced uranium removal to facilitate assay by inductively coupled plasma mass spectrometry (ICP-MS). This method allows rapid preconcentration and separation of plutonium and neptunium in large soil samples for the measurement of {sup 237}Np and Pu isotopes by ICP-MS. {sup 238}U can interfere with {sup 239}Pu measurement by ICP-MS as {sup 238}UH{sup +} mass overlap and {sup 237}Np via {sup 238}U peak tailing. The method provides enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then transferring Pu to DGA resin for additional purification. The decontamination factor for removal of uranium from plutonium for this method is greater than 1 x 10{sup 6}. Alpha spectrometry can also be applied so that the shorter-lived {sup 238}Pu isotope ...

2010-07-26

5

Analysis by mass spectroscope device provided with ion source of induced plasma  

International Nuclear Information System (INIS)

This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including ...

6

Microwave dissolution of plant tissue and the subsequent determination of trace lanthanide and actinide elements by inductively coupled plasma-mass spectrometry  

Energy Technology Data Exchange (ETDEWEB)

Recently there has been much concern with the ability of plants to uptake heavy metals from their surroundings. With the development of instrumental techniques with low detection limits such as inductively coupled plasma-mass spectrometry (ICP-MS), attention is shifting toward achieving faster and more elegant ways of oxidizing the organic material inherent in environmental samples. Closed-vessel microwave dissolution was compared with conventional methods for the determination of concentrations of cerium, samarium, europium, terbium, uranium and thorium in a series of samples from the National Institute of Standards and Technology and from fields in Idaho. The ICP-MS technique exhibited detection limits in parts-per-trillion and linear calibration plots over three orders of magnitude for the elements under study. The results obtained by using nitric acid and hydrogen peroxide in a microwave digestion system for the ...

1997-08-01

7

Elimination of ``memory`` from sample handling and inlet system of a mass spectrometer  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.

1991-05-08

8

Characterization of a time-of-flight mass spectrometer and its applications in the study of solid surfaces; Charakterisierung eines Flugzeitmassenspektrometers und seine Anwendungen in der Festkoerperoberflaechenuntersuchung  

Energy Technology Data Exchange (ETDEWEB)

The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high ...

2006-12-21

9

SOME RECENT DETERMINATIONS OF ATOMIC MASSES IN THE STRONTIUM-ZIRCONIUM REGION  

Science.gov (United States)

A large double-focusing mass spectrometer was used to obtain new values for the masses of Sr/sup 86/, Sr/sup 88/, and Zr/sup 90/. Mass differences calculated from these values are found to be in better agreement with nuclear transmutation information than were previous mass spectroscopically derived values. (auth)

1960-06-01

10

Rapid determination of "2"3"7Np and Pu isotopes in water by inductively-coupled plasma mass spectrometry and alpha spectrometry  

International Nuclear Information System (INIS)

A new method that allows rapid preconcentration and separation of plutonium and neptunium in water samples was developed for the measurement of "2"3"7Np and Pu isotopes by inductively-coupled plasma mass spectrometry (ICP-MS) and alpha spectrometry. "2"3"8U can interfere with "2"3"9Pu measurement by ICP-MS as "2"3"8UH"+ mass overlap and "2"3"7Np via peak tailing. The method provide enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then moving Pu to DGA resin for additional removal of uranium. The decontamination factor for uranium from Pu is almost 100,000 and the decontamination factor for U from Np is greater than 10,000. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration is performed using a streamlined calcium phosphate precipitation method. Purified solutions are split between ...

2011-01-01

11

RAPID DETERMINATION OF 237 NP AND PU ISOTOPES IN WATER BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY AND ALPHA SPECTROMETRY  

Energy Technology Data Exchange (ETDEWEB)

A new method that allows rapid preconcentration and separation of plutonium and neptunium in water samples was developed for the measurement of {sup 237}Np and Pu isotopes by inductively-coupled plasma mass spectrometry (ICP-MS) and alpha spectrometry; a hybrid approach. {sup 238}U can interfere with {sup 239}Pu measurement by ICP-MS as {sup 238}UH{sup +} mass overlap and {sup 237}Np via peak tailing. The method provide enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then moving Pu to DGA resin for additional removal of uranium. The decontamination factor for uranium from Pu is almost 100,000 and the decontamination factor for U from Np is greater than 10,000. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration is performed using a streamlined calcium phosphate precipitation method. ...

2010-06-23

12

PBAR: A superconducting magnet spectrometer for cosmic ray antiproton studies  

Energy Technology Data Exchange (ETDEWEB)

We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).

1990-09-15

13

Expert overseer for mass spectrometer system  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of ...

1991-06-18

14

Expert overseer for mass spectrometer system  

International Nuclear Information System (INIS)

This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of ...

1989-04-04

15

In situ isotopic analyses of U and Pb in zircon by remotely operated SHRIMP II, and Hf by LA-ICP-MS: an example of dating and genetic evolution of zircon by 176Hf/177Hf from the Ita Quarry in the Atuba Complex, SE, Brazil  

International Nuclear Information System (INIS)

Remotely-operated SHRIMP dating of zircon is an interesting alternative for dating of zircon crystals. Although it does not represent any technical progress of the geochronological method using the U-Pb system in zircon it is a very useful and cheap facility. The procedure was first used for mass spectrometric analyses involving two international laboratories in Sao Paulo, Brazil and Beijing, China. It was applied to samples of three gneiss-migmatitic rocks from the Ita quarry in the Atuba Complex (located between the Luis Alves and the Apiai Domain) to test previous controversial hypotheses about its evolution. The presence of important archaean and paleo proterozoic components in the complex is confirmed by analyses of zircon found in probably neo proterozoic leucosomes. Diorite intrusion also occurred during the neo proterozoic, associated with the 0.6Ga continental collisions involved in the assembly of Gondwana. The determination of Hf isotope ratios by ...

2009-10-01

16

Communication and Round Efficient Information Checking Protocol  

CERN Document Server

In this paper, we present a very important primitive called Information Checking Protocol (ICP) which plays an important role in constructing statistical Verifiable Secret Sharing (VSS) and Weak Secret Sharing (WSS) protocols. Informally, ICP is a tool for authenticating messages in the presence of computationally unbounded corrupted parties. Here we extend the basic bare-bone definition of ICP, introduced by Rabin et al. and then present an ICP that attains the best communication complexity and round complexity among all the existing ICPs in the literature. We also show that our ICP satisfies several interesting properties such as linearity property which is an important requirement in many applications of ICP. Though not presented in this paper, we can design communication and round efficient statistical (i.e involves negligible error ...

2010-01-01

17

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. Additionally, larger ...

2008-07-01

18

New focal plane detector system for the broad range spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.

1984-01-01

19

Improved SSAMS performance  

British Library Electronic Table of Contents (United Kingdom)

We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.

2010-01-01

22

Matrix-assisted laser desorption fourier transform mass spectrometry for biological compounds  

Science.gov (United States)

The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the ...

1990-01-01

23

Mass measurements of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc and their impact on the rp-process  

Energy Technology Data Exchange (ETDEWEB)

The masses of the proton-rich nuclides {sup 85,86,87}Mo and {sup 87}Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor ...

2010-07-01

24

Mass measurements of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc and their impact on the rp-process  

International Nuclear Information System (INIS)

The masses of the proton-rich nuclides "8"5","8"6","8"7Mo and "8"7Tc have been measured with the Penning trap mass spectrometer SHIPTRAP at GSI. The measured mass excesses of these nuclei deviate from the values of the Atomic Mass Evaluation 2003 by up to 1.6 MeV, indicating a systematic shift of the mass surface in this region compared to previous measurements. A local mass extrapolation based on the new results has been made for the mass range A=80-95. Measured and extrapolated mass values and the derived separation energies have been compared to theoretical mass models. Taking into account the new mass excess values, rp-process network calculations have been performed. Preliminary results show changes in the final abundances for A=86-92 by up to a factor ...

2010-03-15

25

First direct mass measurement of the proton rich nuclides {sup 85,86,87}Mo and {sup 87}Tc  

Energy Technology Data Exchange (ETDEWEB)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction {sup 36}Ar+{sup 54}Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and {nu}p process paths. The masses of {sup 85}Mo and {sup 87}Tc were measured for the first time. The masses of another two nuclides, {sup 86,87}Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, ...

2009-07-01

26

First direct mass measurement of the proton rich nuclides "8"5","8"6","8"7Mo and "8"7Tc  

International Nuclear Information System (INIS)

The masses of proton rich nuclides in the vicinity of N=Z=43 were measured with the Penning trap mass spectrometer SHIPTRAP at GSI. These nuclei were produced in the fusion-evaporation reaction "3"6Ar+"5"4Fe at energies of 5.0 and 5.9 MeV/u and separated at the velocity filter SHIP. The data are of astrophysical interest since these nuclei are believed to be a part of the rp and #nu#p process paths. The masses of "8"5Mo and "8"7Tc were measured for the first time. The masses of another two nuclides, "8"6","8"7Mo, were determined for the first time in a direct mass measurement. For these nuclides the mass excess deviates from values of the 2003 Atomic Mass Evaluation by up to 1.5 MeV, indicating a systematic shift of the mass surface in this region of the nuclear chart. Additionally, the ...

2009-03-16

27

Multipass laser mass spectrometer with extreme jet-cooled pulsed gas  

International Nuclear Information System (INIS)

We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully ...

2006-09-01

28

Detection of previous neutron irradiation and reprocessing of uranium materials for nuclear forensic purposes  

International Nuclear Information System (INIS)

The paper describes novel analytical methods developed for the detection of previous neutron irradiation and reprocessing of illicit nuclear materials, which is an important characteristic of nuclear materials of unknown origin in nuclear forensics. Alpha spectrometry and inductively coupled plasma sector-field mass spectrometry (ICP-SFMS) using solution nebulization and direct, quasi-non-destructive laser ablation as sample introduction were applied for the measurement of trace-level "2"3"2U, "2"3"6U and plutonium isotopes deriving from previous neutron irradiation of uranium-containing nuclear materials. The measured radionuclides and isotope ratios give important information on the raw material used for fuel production and enable confirm the supposed provenance of illicit nuclear material.

2009-04-01

29

Rapid Sampling of Individual Organic Aerosol Species in Ambient Air with the Photoionization Aerosol Mass Spectrometer  

British Library Electronic Table of Contents (United Kingdom)

Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...

2008-01-01

30

Highly efficient ion source for analysis of transuranium elements  

Energy Technology Data Exchange (ETDEWEB)

Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.

1987-01-01

31

Low-energy fission of nuclei lighter than Hg  

International Nuclear Information System (INIS)

The mass and energy distributions for low-energy p- and alpha-particle induced fission of "1"8"7","1"8"8Ir and "1"9"5Au and "3He-induced fission of sufficiently heated "1"8"8Ir and "1"9"4Au have been measured with use of fast spectrometer of complementary fragments. From Au to Ir, the shape of the mass distributions undergoes substantial changes related to specific dependence of the saddle shell corrections on A and Z fissioning nuclei. The results are compared with theoretical predictions.

32

Accelerator mass spectrometry: state of the art  

Energy Technology Data Exchange (ETDEWEB)

Accelerator Mass Spectrometry (AMS) is the analytical technique of choice for the detection of long-lived radionuclides which cannot be practically analysed with decay counting or conventional mass spectrometry. The main use of AMS has been in the analysis of radiocarbon and other cosmogenic radionuclides for archaeological, geological and environmental applications. In addition, AMS has been recently applied in biomedicine to study exposure of human tissues to chemicals and biomolecules at attomole levels. There is also a world-wide effort to analyse rare nuclides of heavier masses, such as long-lived actinides, with important applications in safeguards and nuclear waste disposal. The use of AMS is limited by the expensive accelerator technology required and there are several attempts to develop smaller and cheaper AMS spectrometers. 5 refs.

1996-12-31

34

Penning trap mass spectrometry of neutron-rich Fe and Co isotopes around N=40 with the LEBIT mass spectrometer  

International Nuclear Information System (INIS)

Penning trap mass spectrometry is presented as a complementary tool to nuclear spectroscopy experiments for the study of nuclear structure in the vicinity of N=40, Z=28. High-precision mass measurements of the "6"3"-"6"6Fe and "6"4"-"6"7Co isotopes have been carried out with the Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer. The newly obtained mass values for "6"6Fe and "6"7Co are presented, together with the previously reported LEBIT mass measurements in this region. In the case of "6"5Fe the existence of a new isomer is reported, and an isomer recently discovered by decay spectroscopy in "6"7Co is confirmed. Relative mass uncertainties as low as 4x10"-"8 are obtained. All mass values are found to be in good agreement with previous experimental results with the exception of "6"4Co, where a 5#sigma# ...

2010-04-01

35

Evaluation of the cleanliness of ultrapure water by the analysis for metal concentration deposited on Si wafer surface using vapor phase decomposition/inductively coupled plasma mass spectrometry  

International Nuclear Information System (INIS)

Along with the shrinkage of LSI geometries, a higher quality of ultrapure water has been continuously required. Analytical technology for ultrapure water has also progressed before ultrapure water production technology improvements. In this study, we performed optimization of the analytical conditions for the direct analysis of acid droplets, and established an analytical technology for measurements of trace amounts of metallic impurities deposited on a wafer surface by means of Vapor Phase Decomposition (VPD)/Inductively Coupled Plasma Mass Spectrometry (ICP-MS). As a result, analytical technology for metallic elements of the 1x10"8 atoms/cm"2 level on wafer surface has been established. By applying analytical technology to the wafer that has been contacted with ultrapure water, a new evaluation technology for ultrapure water quality by means of wafer surface contamination has been established. We confirmed good correlations between metal ...

2010-07-01

36

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer  

CERN Document Server

The study of antiprotons and positrons in cosmic rays with the PAMELA spectrometer

1998-01-01

37

Modifications to the rotating crystal spectrometer  

International Nuclear Information System (INIS)

... bf3 counters data multi-channel analyzers multivibrators neutron spectrometers

38

Recent developments at ISOLTRAP towards a relative mass accuracy of exotic nuclei below $10^{-8}$  

CERN Document Server

During the last two years, the performance of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN (Geneva) has been considerably enhanced. Many technical improvements have been completed (i) to access nuclides that are produced in minute quantities of only 100 ions s/sup -1/, (ii) to increase the relative mass accuracy to

2003-01-01

39

Rapid determination of granisetron in human plasma by liquid chromatography coupled to tandem mass spectrometry and its application to bioequivalence study  

British Library Electronic Table of Contents (United Kingdom)

A simple, sensitive and rapid method for analysis of granisetron in human plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and validated to satisfy FDA guidelines for bioanalytical methods. The analyte and internal standard (IS) were isolated from 100ml plasma samples by liquid-liquid extraction (LLE). A Varian 1200l tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 313.4/138 for granisetron and m/z 270/201 for the IS used for quantitation. The assay exhibited a linear dynamic range of 0.02-20ng/ml for granisetron in human plasma. The lower limit of quantification (LLOQ) was 0.02ng/ml with a relative standard deviati...

2006-01-01

40

Photodegradation of flupentixol in aqueous solution under irradiation at 254nm: Identification of the photoproducts generated  

British Library Electronic Table of Contents (United Kingdom)

After irradiation at 254nm of aqueous solutions of the antipsychotic drug flupentixol, the structures of the photodegradation products were determined by ultra high performance liquid-chromatography linked to mass spectrometry. Fragmentation patterns of the parent ions were established on a hybrid linear ion trap-orbitrap mass spectrometer allowing accurate mass measurements of both parent and daughter ions. This allowed to propose plausible structures for the main photolysis products of flupentixol. A total of nine photoproducts were detected after irradiation of the drug. The main photoproduct is generated following the addition of a hydroxyl group on the double bond adjacent to the thioxanthene ring. Secondary photoproducts were also observed.

2010-01-01

41

Mass measurement of neutron-rich isotopes from [sup 51]Ca to [sup 72]Ni  

Energy Technology Data Exchange (ETDEWEB)

The ground state masses of thirty-nine neutron-rich nuclei from [sup 51]Ca to [sup 72]Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of [sup 68]Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.)

1994-07-01

42

Mass measurement of neutron-rich isotopes from "5"1Ca to "7"2Ni  

International Nuclear Information System (INIS)

The ground state masses of thirty-nine neutron-rich nuclei from "5"1Ca to "7"2Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of "6"8Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.).

43

Liquid chromatography with ultraviolet and dual parallel mass spectrometric detection for analysis of vitamin D in retail fortified orange juice  

British Library Electronic Table of Contents (United Kingdom)

Samples of vitamin D fortified orange juice obtained from retail food stores were analyzed for vitamin D3 content using a method developed by combining the best features of two AOAC methods. Detection by ultraviolet absorption at 265nm was compared to detection by selected ion monitoring (SIM) using atmospheric pressure chemical ionization (APCI) mass spectrometry (MS). Furthermore, an ion trap (IT) mass spectrometer was employed in a 'dual parallel MS' arrangement to simultaneously obtain qualitative APCI-ITMS data. The method was applied to 33 samples of 3 national American orange juice brands and 7 samples of 5 other American brands collected using a statistically designed sampling plan as part of the National Food and Nutrient Analysis Program to provide values for the USDA National Nu...

2011-01-01

44

High Throughput Screening for the Discovery of More Efficient Catalysts for Emissions Control  

Energy Technology Data Exchange (ETDEWEB)

High-throughput synthesis and screening methods have been developed for the discovery of highly active catalysts for the control of emissions from stationary and mobile sources. Low temperature CO oxidation, CO methanation, NOx abatement and the destruction of Volatile Organic Compounds (VOCs) will be discussed. The discovery libraries for primary screening consisted of both 11x11 and 16x16 catalyst arrays on 3 inch and 4 inch quartz wafers, respectively. Catalysts were prepared by robotic liquid dispensing techniques and screened for catalytic activity in Symyx's Scanning Mass Spectrometer. The screening protocols encompassed mixed metal oxides, perovskites and supported base and noble metals. Active hits were further optimized in focus libraries using shallower compositional gradients. The ScanMS is a fast serial screening tool that uses flat wafer catalyst surfaces, local laser heating, a scanning/sniffing nozzle and a quadrupolar ...

2004-03-31

45

Use of a new time of flight aerosol mass spectrometer for ground and airborne measurements of biogenically produced organic aerosols  

Environmental Research Database

DescriptionChamber studies have shown that biogenic organic compounds, including isoprene, are capable of producing secondary organic aerosol in significant quantities. This is surprising as isoprene and its photo-oxidation products have relatively high vapour pressures. However, it is very important as isoprene has the largest global emissions flux of any biogenic hydrocarbon, most of which is in the tropics. Despite this, secondary organic aerosol has been poorly studied in tropical regions with only [continued...

46

Production of cumulative pions and kaons  

International Nuclear Information System (INIS)

#pi#"#+-# and K"#+-# cumulative production in pA #-># #pi#"#+-#+x and pA #-># K"#+-#+x reactions at 10.14 GeV proton beam energy on nuclei (Be-Ta) was invesigated. Measurements were conducted using FAS-1 focusing hadron spectrometer. Invariant cross sections of #pi#"#+-# and K"#+-# cumulative production, values of ratio of this cross sections, dependences of production cross sections for pions and kaons on cumulative number and mass number of nucleus target, as well as on transverse momentum are measured. Difference of cumulative meson spectra occurring in different nuclei fragmentation is discussed in terms of flucton model. 17 refs.; 14 figs.

1988-06-14

47

Electromagnetic decay properties of multiparticle-hole states in neutron deficient Mo and Tc isotopes  

Energy Technology Data Exchange (ETDEWEB)

Neutron deficient nuclei with mass numbers A {approx} 90 and 40 {<=} Z {<=} 44 have been studied making use of the Osiris and Nordball spectrometers. The high spin states of these nuclei and their electromagnetic decay properties are compared to shell model calculations based on the core {sup 88}Sr and using different parametrizations of the residual interaction. The dependence of the mean square deviations of experimental and theoretical level energies, branching ratios, and transition probabilities on the neutron numbers N = 46-50 and the validity of seniority as a good quantum number are discussed. (orig.).

1995-12-31

48

Multielement determination of major-to-ultratrace elements in salmon egg by ICP-AES and ICP-MS  

Energy Technology Data Exchange (ETDEWEB)

The multielement determination of major-to-ultratrace elements in salmon egg was carried out by ICP-AES and ICP-MS. First, salmon eggs (30 eggs used) were digested with conc. nitric acid and 60% perchloric acid by heating almost to dryness repeatedly. Finally, the residues of salmon eggs were dissolved in 1 M nitric acid and the sample solutions were analyzed by ICP-AES and ICP-MS. About 40 elements could be determined over the concentration range in 9 orders of magnitude. The concentrations of bio-essential elements, such as Zn, Fe, and Cu, in salmon egg were 10-100 times higher than those in human blood serum. In addition, the major-to-ultratrace elements in cell cytoplasm and cell membrane were separately determined in a similar manner to those in whole egg cell. The concentrations of most bio-essential elements were higher in cell cytoplasm than in cell membrane, while those of Fe and Cu were higher ...

2002-04-01

50

The search for decaying Dark Matter  

CERN Document Server

We propose an X-ray mission called Xenia to search for decaying superweakly interacting Dark Matter particles (super-WIMP) with a mass in the keV range. The mission and its observation plan are capable of providing a major break through in our understanding of the nature of Dark Matter (DM). It will confirm, or reject, predictions of a number of particle physics models by increasing the sensitivity of the search for decaying DM by about two orders of magnitude through a wide-field imaging X-ray spectrometer in combination with a dedicated observation program. The proposed mission will provide unique limits on the mixing angle and mass of neutral leptons, right handed partners of neutrinos, which are important Dark Matter candidates. The existence of these particles is strongly motivated by observed neutrino flavor oscillations and the problem of baryon asymmetry of the Universe. In super-WIMP models, the details of the ...

2009-01-01

51

Survival of gas phase amino acids and nucleobases in space radiation conditions  

CERN Document Server

We present experimental studies on the photoionization and photodissociation processes (photodestruction) of gaseous amino acids and nucleobases in interstellar and interplanetary radiation conditions analogs. The measurements have been undertaken at the Brazilian Synchrotron Light Laboratory (LNLS), employing vacuum ultraviolet (VUV) and soft X-ray photons. The experimental set up basically consists of a time-of-flight mass spectrometer kept under high vacuum conditions. Mass spectra were obtained using photoelectron photoion coincidence technique. We have shown that the amino acids are effectively more destroyed (up to 70-80%) by the stellar radiation than the nucleobases, mainly in the VUV. Since polycyclic aromatic hydrocarbons have the same survival capability and seem to be ubiquitous in the ISM, it is not unreasonable to predict that nucleobases could survive in the interstellar medium and/or in comets, even as a ...

2008-01-01

52

Measurement of attenuation coefficients for bone, muscle, fat and water at 140, 364 and 662keV ?-ray energies  

International Nuclear Information System (INIS)

The half-value thicknesses, linear and mass attenuation coefficients of biological samples such as bone, muscle, fat and water have been measured at 140, 364 and 662keV ?-ray energies by using the ATOMLABTM-930 medical spectrometer. The ?-rays were obtained from 99mTc, 131I and 137Cs ?-ray point sources. Also theoretical calculations have been performed in order to obtain the half-value thicknesses and, mass and linear attenuation coefficients at photon energies 0.001keV-20MeV for bone, muscle and water samples. The calculated value and the experimental results of this work and the other results in literature are found to be in good agreement.

2006-11-01

53

Bullet injuries of the brain  

UK PubMed Central (United Kingdom)

Experience gained with a wide variety of missile injuries of the brain is presented. Clinical signs and intracranial pressure (ICP) studied in the early post-injury period have been correlated with...Full Text Available

1974-09-01

54

Transfer of elements into mother's milk; Transfer von Elementen in die Muttermilch  

Energy Technology Data Exchange (ETDEWEB)

This research project aimed to determine the factors for the transfer of the elements silver (Ag), cerium (Ce), cobalt (Co), chrome (Cr), gallium (Ga), lanthanum (La), molybdenum (Mo), niobium (Nb), radium (Ra), ruthenium (Ru), antimony (sb), thorium (Th), titanium (Ti) and uranium (U) from food into the mother's milk. This factors will be used as a basic to check and derive activity values for the contamination of food and for radiation protection at working places of suckling women. For this purpose 19 mothers collected samples daily (2-8 weeks), using the duplicate method, of all the food they consumed as well as of their milk. After microwave-assisted digestion the element contents were analysed by mass-spectroscopy with inductive coupled plasma (ICP-MS). The results of the mothers who participate for more than 5 weeks were used to make a time lapse between the intake and transfer of the elements in the mothers milk visible. ...

2000-08-01

55

High-precision Penning-Trap measurements of light-ion masses  

International Nuclear Information System (INIS)

The UW-Penning Trap Mass Spectrometer (PTMs) is ideally suited for high precision measurements of atomic masses throughout the periodic table upon using highly-stripped ions. However, at the present time, this device has been applied extensively to the light elements ("1H, "2H, "3H, "3He, "4He, "1"2C, "1"3C, "1"4N, "1"6O) due to their fundamental importance. Atomic masses follow immediately from a comparison with some multiply-charged carbon ion, after correcting for the lost electrons and their corresponding binding energies. For instance, the most recent C"5"+/C"6"+ comparison yielded a discrepancy of -0.30(33) ppb, limited only by the magnetic field instability for a 40-h run. The initial emphasis on hydrogen has now produced a 1-ppb value for the proton's atomic mass and similar work with deuterium has yielded a 2.5-ppb value for the neutron's atomic mass. ...

1993-04-12

56

A superconducting solenoidal spectrometer for a balloon-borne experiment  

Energy Technology Data Exchange (ETDEWEB)

The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger rate and large data ...

2000-03-21

57

Diagnostics aid for mass spectrometer trouble-shooting  

International Nuclear Information System (INIS)

The MS Expert system provides problem diagnostics for instruments used in the Mass Spectrometry Laboratory (MSL). The most critical results generated on these mass spectrometers are the uranium concentration and isotopic content data used for process control and materials accountability at the Idaho General Processing Plant. The two purposes of the system are: (1) to minimize instrument downtime and thereby provide the best possible support to the Plant, and (2) to improve long-term data quality. This system combines the knowledge of several experts on mass spectrometry to provide a diagnostic tool, and can make these skills available on a more timely basis. It integrates code written in the Pascal language with a knowledge base entered into a commercial expert system shell. The user performs some preliminary status checks, and then selects from among several broad diagnostic categories. These initial ...

58

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental composition focusing on ...

59

Curious Results with Palladium- and Platinum-Carrying Polymers in Mass Cytometry Bioassays and an Unexpected Application as a Dead Cell Stain.  

Science.gov (United States)

We describe the synthesis of metal-chelating polymers (MCPs) with four different pendant polyaminocarboxylate ligands (EDTA, DTPA, TTHA, DOTA) and an orthogonal end-group, either a fluorescein molecule or a bismaleimide linker for antibody attachment. Polymer characterization by a combination of (1)H NMR, UV/vis absorption measurements, and thermal gravimetric analysis (TGA) indicated that each chain of the fluorescein-terminated polymers contained one dye molecule. These polymer samples were loaded with three different types of lanthanide ions as well as palladium and platinum ions. The numbers of metal atoms per chain were determined by a combination of UV/vis and conventional ICP-MS measurements. The experiments with lanthanide ions demonstrated that a net anionic charge on the polymer is important for water solubility. These experiments also showed that at least one type of lanthanide ion (La(3+)) is capable of forming a bimetallic complex with pendant DTPA ...

2011-09-28

60

Direct sampling ion trap mass spectrometry (DSITMS). Innovative technology summary report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the cost, performance, and other key characteristics of an innovative technology for determining the presence or absence, and measuring the concentration, of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) in groundwater and soil, and in gaseous remediation process streams at hazardous waste sites. This new technology is Direct Sampling Ion Trap Mass Spectrometry (DSITMS). DSITMS introduces sample materials directly into an ion trap mass spectrometer by means of a very simple interface, such as a capillary restrictor or a polymer membrane. There is typically very little, if any, sample preparation and no chromatographic separation of the sample constituents. This means that the response of the instrument to the analytes or contaminants in a sample is nearly instantaneous, and that analytical methods based on DSITMS are fast. Analyses are typically completed in less than ...

1998-12-01

61

A gas-jet ECR ion source at TRIGA-SPEC  

International Nuclear Information System (INIS)

The TRIGA-SPEC experiment has been installed recently at the research reactor TRIGA Mainz. Ground state properties like masses, charge radii, spins, and moments of short-lived nuclides can be determined with very-high precision using the Penning trap mass spectrometer TRIGA-TRAP, and the collinear laser spectroscopy setup TRIGA-LASER. Short-lived neutron-rich radionuclides in the mass range 80 < A < 140 are produced by thermal neutron induced fission of e.g. U-235, Pu-239 or Cf-249, respectively. For the extraction and ionization of the fission products a gas-jet system is coupled to a 2.45-GHz ECR ion source for the production of singly charged ions. The gas-jet has been tested on-line and fission products have been extracted. First off-line tests of the ion source have been performed successfully with argon gas. The results of the commissioning test of the ion source and the on-line coupling of ...

2010-03-08

62

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.

1984-03-01

63

Time-of-flight measurements of light molecular ions scattered at grazing incidence from a Ni(111) surface  

International Nuclear Information System (INIS)

A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).

64

Thermal electron attachment and detachment, and electron affinities  

International Nuclear Information System (INIS)

Knighton et al. used a pulsed high pressure mass spectrometer to examine thermal electron detachment from C_6F_6"-. This technique had been used earlier for the measurement or detachment rate coefficients for azulene anions as a function of temperature. C_6F_6"- and c-C_4F_6"- have been studied by Datskos et al. using a pulsed drift tube. In our laboratory, we have used a flowing afterglow Langmuir probe (FALP) apparatus to measure the thermal electron detachment rate coefficient for c-C_4F_8"- ions at 375 K. We have also measured the electron attachment rate coefficient for c-C_4F_8 at 303 K and 375 K. (author).

1994-03-20

65

The microscopic dynamics of condensed parahydrogen  

Energy Technology Data Exchange (ETDEWEB)

We have measured the almost-pure incoherent scattering function of liquid and solid parahydrogen, using inelastic neutron scattering. The experiments were carried out on TOSCA, a time-of-flight, inverse-geometry, crystal-analyzer spectrometer, operating on the pulsed neutron source at ISIS (UK). The experiments have been planned taking advantage of the intrinsic incoherence introduced in the scattering process by the rotational transitions. The measured double-differential cross section gives a direct experimental access to the microscopic dynamics of condensed hydrogen. From the high-energy region of the spectrum, where the impulse approximation for the center of mass motion applies, we have been able to extract the translational mean kinetic energy. In the low-energy region, using the Gaussian approximation, we compare the experimental data in the liquid phase with the results of a model for the velocity autocorrelation function. The results ...

2002-07-01

66

Retention of ring structure in cyclopentane and alkylcyclopentane molecular cations  

Energy Technology Data Exchange (ETDEWEB)

All measurements were made with the NBS high-pressure photoionization mass spectrometer. The fractional of C/sub 5/H/sub 10//sup +/ions in a cyclopentane-cyclohexane mixture were determined as a function of pressure in order to define the fraction of the ions which did charge exchange with cyclohexane; i.e. the fraction which remained cyclic after ionization. The data for mixtures of various compositions (2.5 to 10% cyclohexane) are summarized for measurements performed at 10.62 eV: (a) 292K, > 96% cyclic; 347 K, greater than or equal to 94% cyclic; 386 K, 84 +- 4% cyclic; and 412 K, 78 +- 6% cyclic; entropy, enthalpy, and activation energy were determined; 10.49 eV was obtained as the ionization potential of cyclopentane. 1 figure.

1980-01-01

67

KLOE-2 experiment at DA$\\Phi$NE upgraded in luminosity  

CERN Document Server

Prospective presentation is given for the experimental program of the KLOE-2 Collaboration, to be performed using the DA$\\Phi$NE $e^+e^-$ collider upgraded in luminosity. Data with the total luminosity of 25 fb$^{-1}$ are aimed to be collected in 3 years. Major modifications of the accelerator and the spectrometer are described. The KLOE-2 physics program contains: CKM unitarity and lepton universality tests, $\\gamma\\gamma$ physics, search for quantum decoherence and testing CPT conservation, low-energy QCD, rare kaon decays, physics of $\\eta$ and $\\eta^\\prime$, structure of low-mass scalars, contribution of vacuum polarization to $(g-2)_{\\mu}$, possible search for WIMP dark matter. In this paper only selected physics subjects are reported.

2011-01-01

68

Indirect Dark Matter Signals  

CERN Document Server

Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. Several signatures, ranging from the positron excess, as observed by HEAT, AMS-01 and PAMELA, the gamma ray excess, as observed by the EGRET spectrometer, the WMAP-haze, and constraints from antiprotons, as observed by CAPRICE, BESS and PAMELA, have been discussed in the literature. Unfortunately, the different signatures all lead to different WIMP masses, indicating that at least some of these interpretations are likely to be incorrect. Here we review them and discuss their relative merits and uncertainties. New x-ray data from ROSAT suggests non-negligible convection in our Galaxy, which leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in the halo to outer ...

2008-01-01

69

Explosives sensor  

Energy Technology Data Exchange (ETDEWEB)

A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this device's construction and ...

1987-01-01

70

Effects of ion irradiation on the diffusion of pre-implanted B atoms in crystalline silicon  

International Nuclear Information System (INIS)

N-type crystalline Si (100) implanted with 5 keV B ions was subsequently irradiated with MeV Si, O and F ions. The B atom profiles were measured by means of secondary ion mass spectrometer after the treatment of rapid thermal annealing. The results show that the transient enhanced diffusion of B atoms is effectively limited by the post-implantation of high energy ions at high dose. At the same irradiation conditions, it is found that the existence of a SiO_2 layer in the near surface of Si is even more effective in suppressing the transient enhanced diffusion of the doped B atoms. The results are qualitatively discussed in combination with the analyses of RBS/c measurements and calculation of the DICADA code

2001-12-01

71

Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge  

British Library Electronic Table of Contents (United Kingdom)

The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...

2010-01-01

72

Barium carbonate sediment sampling for inorganic dissolved carbon using isotope mass ratio spectrometer  

International Nuclear Information System (INIS)

This paperwork explain the method of water sampling to obtain the precipitate of BaCO3 solutions that will be used to analyze 13C from field work in Kelana Jaya, Selangor, Langkawi, Kedah and Taiping, Perak. The sampling involves collecting of water samples for groundwater from boreholes and surface water from canal, river, pond and ex-mining pond from several locations at the study sites. This study also elaborates the instruments and chemicals used. The main purpose of this sampling is to obtain the precipitate of BaCO3 for 13C analysis of dissolved inorganic carbon (DIC). A correct sampling method according to standard is very important to ensure an accurate and precise result. With this, the data from the laboratory analysis result can be fully utilized to make the interpretation of the pollutants movement. (Author)

2009-10-06

73

RED NUGGETS AT z #approx# 1.5: COMPACT PASSIVE GALAXIES AND THE FORMATION OF THE KORMENDY RELATION  

International Nuclear Information System (INIS)

We present the results of Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) imaging of a sample of 19 high-mass passively evolving galaxies with 1.2 < z < 2, taken primarily from the Gemini Deep Deep Survey (GDDS). Around 80% of galaxies in our GDDS sample have spectra dominated by stars with ages #approx#>1 Gyr. Our rest-frame R-band images show that most of these objects have compact regular morphologies which follow the classical R "1"/"4 law. These galaxies scatter along a tight sequence in the size versus surface brightness parameter space which defines the Kormendy relation. Around one-third (3/10) of the massive red objects in the GDDS sample are extraordinarily compact, with effective radii under 1 kpc. Our NICMOS observations allow the detection of such systems more robustly than is possible with optical (rest-frame UV) data, and while similar systems have been seen at z #approx#> 2, this is the first time such ...

2009-04-10

74

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

75

Trace element analysis in CRM of plant origin by inductively coupled plasma mass spectrometry  

International Nuclear Information System (INIS)

Three CRMs of plant origin (SRM 1515 Apple Leaves, SRM 1570a Trace Elements in Spinach Leaves, and SRM 1575 Pine Needles) were used for analytical quality assurance of Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Mo, Cd, and Pb determination by ICP-MS. The samples were decomposed using microwave assisted pressurized digestion by HNO_3 and HNO_3 + H_2O_2 mixture and temperature programmed dry ashing. Concentrations of elements in samples were evaluated by external calibration. All samples, blanks, and standards were spiked to 100 #mu#g/L concentration of In and Bi as internal standards. During the measurement, signals of "5"2Cr, "5"3Cr, "5"4Fe, "5"5Mn, "5"9Co, "6"0Ni, "6"2Ni, "6"3Cu, "6"5Cu, "6"6Zn, "9"5Mo, "1"1"1Cd, "1"1"2Cd, "1"1"5In, "2"0"6Pb, "2"0"7Pb, "2"0"8Pb and "2"0"9Bi were monitored. Results of Pb, Cd, Cu, Zn, Mo and Co determination were in good agreement with certified values. In order to obtain accurate results for As at low levels, it was necessary to ...

1997-04-21

76

Effects of several variables on whole effluent toxicity test performance and interpretation  

Energy Technology Data Exchange (ETDEWEB)

Protocol changes and options contained within US Environmental Protection Agency whole effluent toxicity tests represent variables that have the potential to affect bioassay performance and interpretation of results. Variables evaluated in this study include: the change in allowable age in the Pimephales promelas acute bioassay from up to 90 d to a maximum of 14 d, age-specific acute responses of P. promelas among the allowable ages of 1 to 14 d, change in the chronic growth endpoint definition from final mass to biomass, differences between hemacytometer and fluorometer measurements in the Selenastrum capricornutum protocol, and options for statistical interpretation of species sensitivity in multiple test/species screening bioassays. Clear age-related sensitivity and precision differences were observed in acute responses of P. promelas. Results obtained using the younger age classes were typically more variable in studies of both 1- to 14-d-old and 14- to ...

2000-01-01

77

Inclusive K{sup +}-meson production in proton-nucleus interactions  

Energy Technology Data Exchange (ETDEWEB)

The production of K{sup +}-mesons in pA(A=D,C,Cu,Ag,Au) collisions has been investigated at the COoler SYnchrotron COSY-Juelich for beam energies T{sub p}=1.0-2.3 GeV. Double differential inclusive pC cross-sections at forward angles {theta}{sub K+}<12 as well as the target mass dependence of the K{sup +} momentum spectra have been measured with the ANKE spectrometer. Far below the free NNthreshold at T{sub NN}=1.58 GeV the spectra reveal a high degree of collectivity in the target nucleus. From the target mass dependence of the cross-sections at higher energies, the repulsive in-medium potential of the K{sup +}-mesons can be deduced. Using pNcross-section parameterisations from the literature and our measured pD data we derive a cross-section ratio {sigma}(pn{yields}K{sup +}X)/{sigma}(pp{yields}K{sup +}X) {proportional_to}(3-4). (orig.)

2004-11-01

78

Phenomenological studies on structure and elemental composition of nanosecond and femtosecond laser-generated aerosols with implications on laser ablation inductively coupled plasma mass spectrometry  

International Nuclear Information System (INIS)

In laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS), the properties of laser-generated aerosols, such as size and composition, are crucial for matrix-independent quantification. In this study, the aerosol particle morphology and elemental composition generated by two state-of-the-art laser systems (ArF excimer nanosecond-UV laser and Ti:sapphire femtosecond-IR laser) were investigated by electron microscopic techniques. Electrostatic sampling of the aerosols directly onto transmission electron microscopy (TEM) grids allowed us to study the morphology and elemental composition of the aerosols using TEM and TEM-EDX (energy dispersive X-ray spectroscopy) analyses, respectively. The results of the electron microscopic studies were finally compared to the LA-ICPMS signals of the main matrix components. The investigations were carried out for non-conducting materials (glass and zircon), metallic samples (steel and brass) and semiconductors ...

79

Determination of As, Cd, Pb, and Hg in urine using inductively coupled plasma mass spectrometry with the direct injection high efficiency nebulizer  

Energy Technology Data Exchange (ETDEWEB)

The application of the large-bore direct injection high efficiency nebulizer (LB-DIHEN) for the determination of arsenic (As), cadmium (Cd), lead (Pb), and mercury (Hg) in urine by inductively coupled plasma mass spectrometry (ICP-MS) is described. The LB-DIHEN is compared with the standard method using a concentric pneumatic nebulizer and cyclonic spray chamber. In addition to the toxicological significance of As, Cd, Pb, and Hg, these elements represent a cross-section of analytical issues including spectral interferences (e.g., {sup 40}Ar{sup 35}Cl{sup +} on {sup 75}As{sup +} and {sup 98}Mo{sup 16}O{sup +} on {sup 114}Cd{sup +}) and memory effects (Hg). In this study, the low sample consumption of the LB-DIHEN is used to reduce the volume of urine needed for analysis, and to reduce the volume of final diluted sample required for analysis. Eliminating the spray chamber and reducing the dead volume of the nebulizer reduces memory effects, ...

2008-03-15

80

The sup(187m)Ir isomer state and its decay scheme  

International Nuclear Information System (INIS)

... beta spectrometers comparative evaluations data decay electrons

81

The conversion spectrum of Sr"8"8  

International Nuclear Information System (INIS)

... beta spectrometers decay energy-level transitions k conversion l conversion

86

Neutrino masses in the MSSM  

CERN Document Server

Neutrino masses in the MSSM

2007-01-01

87

Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The process is observed to be dominated by the ...

1988-11-01

88

TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment  

Energy Technology Data Exchange (ETDEWEB)

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided ...

2005-03-17

89

Population of nuclei close to N=Z line for A{approx}100 through emission of complex fragments and light charged particles  

Energy Technology Data Exchange (ETDEWEB)

High spin states of the proton rich nuclei in the mass region A {approx} 100 have been studied at the GASP spectrometer through the evaporation of light charged particles and heavier ions detected in the 4{pi} Si-ball Isis. Rear side injection and pulse shape analysis have allowed a good discrimination among protons, alpha particles and heavy ions up to C. Of the several nuclei populated in the reactions we will discuss here the high spin states of {sup 105} Sn. In addition to an extension of the spherical level, scheme, a regular sequence of dipole transitions has been found, The states of the dipole band are suggested to be built on a neutron h{sup 2}{sub 11/2} excitation coupled to proton particle-hole states, which polarize the core to a slightly prolate shape. The experimental results are in agreement with the prediction of tilted axis cranking calculations, which satisfactorily explain the properties of the band. (author) 17 refs., 4 ...

1997-12-31

90

Oxygen carriers for chemical looping combustion of solid fuels  

Energy Technology Data Exchange (ETDEWEB)

A thermal analyzer-differential scanning calorimeter-mass spectrometer (TG-DSC-MS) was used to study oxygen carriers (OC) for their potential use for the application of chemical looping combustion (CLC) to solid fuels. Reaction rates, changes in reaction rates with repeated oxidation-reductions, exothermic heats during oxidation, and the effect of changing reduction gas compositions were studied. Oxidation rates were greater than reduction rates and reaction rates were reproducible through multiple oxidation-reduction cycles except where agglomeration occurred with powders. Iron oxide (Fe{sub 2}O{sub 3} powder) and iron-based catalysts were found suitable for CLC of solid fuels having rapid reduction rates which increased with higher reducing gas concentrations. Fe{sub 2}O{sub 3} powder was used to oxidize a high carbon coal char in an inert gas removing 88% of the carbon from the char. Other properties such as cost and durability indicated ...

2009-05-15

91

Measurement of the Electron Affinities of Indium and Thallium  

Energy Technology Data Exchange (ETDEWEB)

The electron affinities of indium and thallium were measured in separate experiments using the laser-photodetachment electron spectroscopy technique. The measurements were performed at the University of Nevada, Reno. Negative ion beams of both indium and thallium were extracted from a cesium-sputter negative ion source, and mass analyzed using a 90{sup o} bending magnet. The negative ion beam of interest was then crossed at 90{sup o} with a photon beam from a cw 25-Watt Ar{sup +} laser. The resulting photoelectrons were energy analyzed with a 160{sup o} spherical-sector spectrometer. The electron affinity of In({sup 2}P{sub 1/2}) was determined to be 0.404 {+-} 0.009 eV and the electron affinity of thallium was determined to be 0.377 {+-} 0.013 eV. The fine-structure splittings in the ground states of the negative ions were also determined. The experimental measurements will be compared to several recent theoretical predictions.

1999-03-20

92

Formation of Si-nanoparticles in a microwave reactor: Comparison between experiments and modelling  

International Nuclear Information System (INIS)

The formation and growth of silicon-nanoparticles from silane in a microwave reactor was investigated. Experiments were performed for the following conditions: precursor concentration 380-2530 ppm, pressures of 20-30 mbar, microwave powers 120-300 W. The formed particles were examined in-situ with a particle mass spectrometer. Additionally, particles were collected on grids and analyzed by transmission electron microscopy, X-ray diffraction, and by determining the specific surface area by BET. The particle size was found to be in the range of 5-8 nm in diameter. A simple model was used to simulate the particle formation processes taking place inside the reactor. The microwave energy coupled into the reactor flow was treated as a spatially distributed energy source resulting in a local temperature increase. The particles were assumed to have a monodisperse size distribution. To allow an approximation of their shape they were characterized by ...

2005-02-01

93

Effect of various coal contaminants on the performance of solid oxide fuel cells: Part II. ppm and sub-ppm level testing  

Energy Technology Data Exchange (ETDEWEB)

The poisoning effects of various trace contaminants in the coal-derived syngas stream at ppm and sub-ppm level on the performance of Ni-YSZ/YSZ/LSM solid oxide fuel cells were studied at extended duration. The thermochemical nature of impurities such as PH{sub 3}(g) and CH{sub 3}Cl(g) in presence and absence of water steam was analyzed by a high temperature mass spectrometer. Only less than half of PH{sub 3}(g) is hydrolyzed, and CH{sub 3}Cl(g) also co-exist with HCl(g). After a certain duration of exposure, 1 ppm AsH{sub 3}(g), 0.5 ppm PH{sub 3}(g), and 2.5 ppm CH{sub 3}Cl(g) all caused some degree of degradation to the power density at 750 C. Whereas 1 ppm of H{sub 2}S(g) resulted in immediate performance loss. The mechanisms of degradation are mainly divided into two categories: surface adsorption effect (for S and Cl) and bulk reaction effect (for As and P). The controversies regarding the poisoning effect and mechanism of S are also ...

2009-09-05

94

Dynamic behaviors of sulfur evolved in the gas phase from pyrolysis of six Chinese coals  

Energy Technology Data Exchange (ETDEWEB)

Dynamic behaviors of gaseous sulfur-containing compounds evolved from pyrolysis of six Chinese coals were studied in the temperature range of up to 800{sup o}C under N{sub 2} and H{sub 2}. The released amount of total sulfur-containing gases was traced by an online flame photometric detector (FPD). Simultaneously, the changes of different sulfur forms, including H{sub 2}S, SO{sub 2}, COS and CS{sub 2}, also were investigated using an online mass spectrometer (MS). FPD results show that the effect of H{sub 2} on gaseous sulfur evolved is complex, which promoted certain peak and suppresses other peaks. Based on the data from MS, it is suggested that a series of competitive reactions between active sulfur and other active matters during pyrolysis may impact on the sulfur form in gas phase. Interactions between active sulfur-containing intermediates and the coal matrix are attributed to be the main factor determining the dynamic behavior.

2006-07-01

95

Determination of plutonium in soil samples by ICP-MS after radiochemical separation procedure  

International Nuclear Information System (INIS)

A method was developed for the determination of plutonium in the soil samples by ICP-MS with TOA extraction chromatographic column. The optimized sample loading rate is below 0.2 mL/min (column inner diameter is 3.5 mm). Using hot 0.02 mol/L oxalic acid (H_2C_2O_4) in 0.16 mol/L HNO_3 to elute Pu from the solid phase in the column. The Pu recovery of 87.3%-96.8% in soil samples was obtained. The plutonium is separated with the ion exchange method in this work. Both extraction chroma- tography and ion-exchange methods efficiently remove the uranium and matrix interference from the ICP- MS measurement. The instrumental detection limit for "2"3"9Pu was 0.48 pg/mL, which corresponds to 1, 1 mBq/mL. (authors)

2008-03-01

96

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers  

UK PubMed Central (United Kingdom)

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available

2011-03-01

97

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

98

USSR Report, Electronics and Electrical Engineering.  

Science.gov (United States)

... comparative analysis is made of the sensitivity of two types of spectrometers: instruments employing coherent spontaneous radiation, and classical ...

1985-04-30

99

Electron-induced luminescence and x-ray spectrometer development: progress report  

Science.gov (United States)

The progress in the development of a surface analysis tool based on the excitation of characteristic

2003-01-01

100

Electron-Induced Luminescence and X-Ray Spectrometer (ELXS) System for Life Detection  

Science.gov (United States)

The ELXS concept is a novel, portable, micro-instrument targeted for the detection of mineralogic

2002-01-01

101

Rapid and cost-effective assessment of connectivity among assemblages of Choerodon rubescens (Labridae), using laser ablation ICP-MS of sagittal otoliths  

British Library Electronic Table of Contents (United Kingdom)

A rapid and cost-effective assessment was required to provide advice to management on the connectivity between juvenile and adult life cycle stages of Baldchin Groper Choerodon rubescens, a labrid endemic to the west coast of Australia, which has high social value, but relatively low commercial fishery importance. To minimise costs we used laser ablation ICP-MS to analyse levels of a small suite of elements (Ca, Mg, Mn, Cu, Zn, Sr, Rb, Ba and Pb) at the margin (adult phase) and core (juvenile phase) of the same otoliths of adult C. rubescens, collected at ten locations in five management zones. The elemental composition of both otolith margins and cores differed significantly among management zones and in some cases among locations within zones. Similarity of the pattern of among-zone elem...

2011-01-01

102

FOCUS: time-of-flight spectrometer for cold neutrons at SINQ  

Energy Technology Data Exchange (ETDEWEB)

The physical layout of the Time-Of-Flight spectrometer at the new spallation source SINQ is presented. The concept shows up a hybrid-TOF combining a Fermi-chopper with a crystal monochromator. The demand of a versatile and flexible instrument for several applications is taken into account by the option of switching from time-focusing to monochromatic focusing mode such that the spectrometer can be optimised for both quasielastic and inelastic scattering applications. (author) 5 figs., 2 tabs., 16 refs.

1996-11-01

103

A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations  

Science.gov (United States)

A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations, however overall standard deviations depend on the skill of the student and their willingness to be careful and precise.

2004-12-01

104

ICPES analyses using full image spectra and astronomical data fitting algorithms to provide diagnostic and result information  

Energy Technology Data Exchange (ETDEWEB)

ICP emission analyses are prone to errors due to changes in power level, nebulization rate, plasma temperature, and sample matrix. As a result, accurate analyses of complex samples often require frequent bracketing with matrix matched standards. Information needed to track and correct the matrix errors is contained in the emission spectrum. But most commercial software packages use only the analyte line emission to determine concentrations. Changes in plasma temperature and the nebulization rate are reflected by changes in the hydrogen line widths, the oxygen emission, and neutral ion line ratios. Argon and off-line emissions provide a measure to correct the power level and the background scattering occurring in the polychromator. The authors` studies indicated that changes in the intensity of the Ar 404.4 nm line readily flag most matrix and plasma condition modifications. Carbon lines can be used to monitor the impact of organics on the analyses and calcium and ...

1997-10-01

105

Determination of Y, Ba and Cu in superconductor films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide x-ray fluorescence analysis was used for the determination of Y, Ba and Cu in thin high-temperature superconducting films. Atomic emission ICP spectrometry was used to estimate the precision and accuracy of analytical results. Reasonable agreement between both methods was obtained when a polynomial calibration curve was applied. (author) 4 refs.; 4 tabs.

1994-06-01

106

Analysis of high-temperature superconducting films by x-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis was used for the determination of Cu, Y and Ba in very thin high-temperature superconducting films. The precision of the method is better than 3% for about 1 #mu#m thick films. The atomic emission ICP spectrometry was used to testify results of XRF analysis. An acceptable agreement of both methods was obtained. (author) 4 refs.; 2 tabs.

1991-09-01

107

Aerosol composition, chemistry, and source characterization during the 2008 VOCALS Experiment  

Energy Technology Data Exchange (ETDEWEB)

Chemical composition of fine aerosol particles over the northern Chilean coastal waters was determined onboard the U.S. DOE G-1 aircraft during the VOCALS (VAMOS Ocean-Cloud-Atmosphere-Land Study) field campaign between October 16 and November 15, 2008. SO42-, NO3-, NH4+, and total organics (Org) were determined using an Aerodyne Aerosol Mass Spectrometer, and SO42-, NO3-, NH4+, Na+, Cl-, CH3SO3-, Mg2+, Ca2+, and K+ were determined using a particle-into-liquid sampler-ion chromatography technique. The results show the marine boundary layer (MBL) aerosol mass was dominated by non- sea-salt SO42- followed by Na+, Cl-, Org, NO3-, and NH4+, in decreasing importance; CH3SO3-, Ca2+, and K+ rarely exceeded their respective limits of detection. The SO42- aerosols were strongly acidic as the equivalent NH4+ to SO42- ratio was only ~0.25 on average. NaCl particles, presumably of sea-salt origin, showed chloride deficits but retained ...

2010-03-15

108

A driving system for Moessbauer spectrometer  

International Nuclear Information System (INIS)

The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 #+-# 0.01 mm/s. (author). 6 figs., 8 refs.

109

The cross sections of (n, x) nuclear reactions on Pb and Bi at the neutron energy 14.6 MeV  

International Nuclear Information System (INIS)

... compton spectrometers cross sections energy resolution energy-level transitions

2000-06-14

110

Remote Sensor Systems for Unmanned Planetary Missions  

Science.gov (United States)

instrument is shown in Figure 4-9 The incoming radiation is focused onto ...... An early rocket-borne ultraviolet spectrometer of the Ebert type by ...

111

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

112

Neutron time-of-flight spectroscopy and the reaction "8"8Sr("3He,n)"9"0Zr  

International Nuclear Information System (INIS)

... states helium 3 reactions ion sources mev range 10-100 neutron spectrometers

113

Electron-induced luminescence and x-ray spectrometer development  

Science.gov (United States)

Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...

114

Utilization of a "1"3C enriched tracer for carbon flux studies in a tropical Eucalyptus exserta forest  

International Nuclear Information System (INIS)

Severe depletion of nutrients through removal of the above ground litter caused a cessation of growth of a Eucalyptus exserta forest in tropical China. Since there is no above ground input of C in this forest, microbial biomass (C_m_i_c) and soil organic C (C_o_r_g) are maintained by the below ground input only. By determining the maintenance requirement of the soil microflora, it should be possible to estimate the below ground production of this forest. To check this hypothesis the authors performed an experiment with labelled C. Since large scale production and field application of "1"4C labelled Eucalyptus litter were not feasible, 'naturally labelled' C_4 plant litter (Zea mays) was used. Maize litter has a #delta#"1"3C of -12.7 per mille as compared with a #delta#"1"3C of -30.7 per mille for Eucalyptus leaf litter. The "1"3C abundance is used to determine the amount of maize C in each of the soil layers. Investigations were made of how supplementation of the soil with litter ...

1990-10-01

115

Thermal stability of nanocomposite CrC/a-C:H thin films  

International Nuclear Information System (INIS)

The thermal stability of low-friction Me-C/a-C:H coatings is important for their potential applications in the tool and automotive industry. Recently we showed that CrC _x/a-C:H coatings prepared by unbalanced magnetron sputtering of a Cr target in Ar + CH_4 glow discharges exhibit a nanocomposite structure where metastable fcc CrC nanocrystals are encapsulated by an a-C:H phase. Here, we present the structural evolution of these nanocomposite CrC/a-C:H coatings during annealing. High-temperature X-ray diffraction in vacuum and differential scanning calorimetry (DSC) combined with thermo-gravimetric analysis in Ar atmosphere indicate decomposition of the formed metastable fcc CrC phase and subsequent formation of Cr_3C_2 and Cr_7C_3 and structural transformation of the a-C:H matrix phase towards higher sp"2 bonding contents at temperatures above 450 deg. C. Combined DSC and mass spectrometer analysis as well as elemental profiling after ...

2007-05-07

116

Purification of CH{sub 3}Cl from CH{sub 3}I using cold trap with sealed 2,2,4-trimethylpentane for {delta}{sup 37}Cl measurement  

Energy Technology Data Exchange (ETDEWEB)

A cryogenic separation method of chloromethane (CH{sub 3}Cl) from methyl iodide (CH{sub 3}I) for {delta}{sup 37}Cl measurement with isotope ratio mass spectrometer is described. A cold trap with sealed 2,2,4-trimethylpentane (TMP) as the cryogen is used in this method. CH{sub 3}Cl can be separated from CH{sub 3}I at the TMP melting point (-107 deg. C) based on the difference in the vapor pressure between CH{sub 3}Cl (322.6 Pa) and CH{sub 3}I (lower than 1.3 Pa) at -107 deg. C. After two-step separation processes, the yields of CH{sub 3}Cl purified from CH{sub 3}Cl-CH{sub 3}I mixture are 96-101%, and the difference between the {delta}{sup 37}Cl{sub original} and {delta}{sup 37}Cl{sub Afterseparation} is from -0.06 to +0.06 per mille (0.01 {+-} 0.04 per mille ). These results suggest that CH{sub 3}Cl is completely separated from CH{sub 3}I with no change of {delta}{sup 37}Cl value. This method using the cold trap with sealed TMP is very safe and ...

2006-01-05

117

Products of the Benzene + O(3P) Reaction  

Science.gov (United States)

The gas-phase reaction of benzene with O(3P) is of considerable interest for modeling of aromatic oxidation, and also because there exist fundamental questions concerning the prominence of intersystem crossing in the reaction. While its overall rate constant has been studied extensively, there are still significant uncertainties in the product distribution. The reaction proceeds mainly through the addition of the O atom to benzene, forming an initial triplet diradical adduct, which can either dissociate to form the phenoxy radical and H atom, or undergo intersystem crossing onto a singlet surface, followed by a multiplicity of internal isomerizations, leading to several possible reaction products. In this work, we examined the product branching ratios of the reaction between benzene and O(3P) over the temperature range of 300 to 1000 K and pressure range of 1 to 10 Torr. The reactions were initiated by pulsed-laser photolysis of NO2 in the presence of benzene and helium buffer in a ...

2009-12-21

118

HPLC-APCI-MS analysis of triacylglycerols (TAGs) in historical pharmaceutical ointments from the eighteenth century.  

Science.gov (United States)

The lipid fractions of residues from historical pharmaceutical ointments were analysed by reversed-phase liquid chromatography coupled with atmospheric pressure chemical ionization and mass spectrometer detection. The residues were contained in a series of historical apothecary jars, dating from the eighteenth century and conserved at the "Aboca Museum" in Sansepolcro (Arezzo, Italy) and at the pharmacy of the "Real Cartuja de Valldemossa" in Palma de Majorca (Spain). The analytical protocol was set up using a comparative study based on the evaluation of triacylglycerol (TAG) compositions in raw natural lipid materials and in laboratory-reproduced ointments. These ointments were prepared following pharmaceutical recipes reported in historical treatises and used as reference materials. The reference materials were also subjected to stress treatments in order to evaluate the modification occurring in the TAG profiles as an effect of ageing. TAGs ...

2011-06-29

119

Characterization and Source Term Assessments of Radioactive Particles from Marshall Islands Using Non-Destructive Analytical Techniques  

Energy Technology Data Exchange (ETDEWEB)

A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and elemental distribution ...

2005-06-11

120

An experimental investigation of H{sub 2} emissions of a 2004 heavy-duty diesel engine supplemented with H{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Hydrogen (H{sub 2}) emissions characteristics of H{sub 2}-diesel dual fuel engine were measured using a 2004 turbocharged heavy-duty diesel engine with H{sub 2} supplemented into the intake air. The emissions of H{sub 2} were measured using an Electron Pulse Ionization (EPI) Mass Spectrometer (MS). The effect of the amount of H{sub 2} added, the engine load, and diesel fuel flow rates on the emissions of H{sub 2} and its combustion efficiency in the engine were investigated. The addition of H{sub 2} under high load operation was notable for its ability to obtain high H{sub 2} combustion efficiency and improve brake thermal efficiency. However, the addition of H{sub 2} at low load resulted in high emissions of H{sub 2} due to the failure to initiate and support a sufficiently vigorous flame for the complete combustion of H{sub 2} present outside the diesel spray plume. The maximum H{sub 2} emissions of 1.4% (volume in dry exhaust gas) were ...

2010-10-15

121

Preparation of immission dust samples for the analysis of toxic substances in dust by atomic emission spectroscopy with inductively coupled plasma  

International Nuclear Information System (INIS)

Samples of air-dust-concentration- and air-dust-deposit measurements were digested by a standardized wet digestion procedure and the amounts of substances in the dust according to class I TA Luft by Atomic Emission Spectroscopy with Inductively Coupled Plasma (AES-ICP). The characteristic values for procedures according to VDI 2449, sheet 1, were determined for lead, vanadium, cadmium, chromium, copper, nickel and zinc. By partial automatic control of the digestion procedure the personel expenditure of work could be reduced by a factor 13. Dust filter samples were analysed without sample preparation by evaporating the material with a solid state laser. The absolute detection limit was between 1 and 100 ng/cm"2 for the elements arsenic, cadmium, cobalt, chromium, mercury, antimony, selen and thallium. For sampling by means of the Beta-Staubmeter the relative detection limits for the laser-ICP were 10-fold lower than by use of a nebulizer. ...

122

Neutron activation analysis of Permian-Triassic (P-Tr) boundary layer at Selong site in China  

Energy Technology Data Exchange (ETDEWEB)

Since living things began their activities on the earth, the extermination of living things in large number on global scale occurred twice 230 million years ago (P-Tr boundary) and 65 million years ago (K-T boundary). As to the cause of exterminating living things in short period, there are volcano eruption theory, meteorite collision theory and so on, but still it is not decided. Therefore, as to the strata of P-Tr boundary in south-western part of China where it has been known the preservation of P-Tr strata is especially good, the existence of elements was measured by instrument neutron activation analysis and ICP-MS, and the state of change was examined. According to the results, the change occurred at the P-Tr boundary on the earth, and further, the possibility of meteorite collision by paying attention to Ir were examined. The samples, the neutron activation analysis, the ICP-MS and the results are reported. The distinction by strata and ...

1994-07-01

123

Inductively coupled plasma nitriding of chromium electroplated AISI 316L stainless steel for PEMFC bipolar plate  

Energy Technology Data Exchange (ETDEWEB)

Chromium electroplated AISI 316L stainless steel was nitrided using inductively coupled plasma (ICP) for application in the bipolar plate of a polymer electrolyte membrane fuel cell (PEMFC). A continuous and thin chromium nitride layer was formed at the surface of the samples after ICP nitriding for 2 h at 400 C. The interfacial contact resistance (ICR) and corrosion resistance in simulated PEMFC operating conditions were higher than the required values, while they varied with the applied dc bias voltage during the nitriding process. The ICR value decreased with an increase in bias voltage. Potentiodynamic polarization measurements showed that all of the nitrided samples had excellent corrosion resistance with a current density of {proportional_to}10{sup -7} A cm{sup -2} at the cathode. It was also found that the oxygen content at the surface was not increased after the corrosion test. X-ray diffractometry (XRD), field emission scanning ...

2009-03-15

124

Determination of impurities in sialon by ICP-AES  

International Nuclear Information System (INIS)

Impurities (Ca, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Ti, Y, Zn and Zr) in sialon powder were determined by the following procedure: A sample (0.5 g) was heated with a mixture of hydrofluoric acid (3 ml) and nitric acid (1 ml) in a Teflon pressure vessel at 170degC for 16 h. The contents of the vessel were transferred into a platinum crucible containing phosphoric acid (4 ml) and heated on a hot plate until the opaque appearance of the content changed to a clear-syrupy fluid. The fluid was diluted to 100 ml with water and used for ICP-AES analysis of all impurity elements except K, which was determined by AAS. It was necessary to match closely the matrix concentrations (H_3PO_4, Al and/or Y) of the standard solutions with those of sialon sample solutions for the determination of impurities because of interferences of the matrix components. This method was successfully applied to the determination of impurities in commercial sialon samples. (author).

125

Comparison of plasma chemistries for inductively coupled plasma etching of InGaAlP alloys  

International Nuclear Information System (INIS)

Two plasma chemistries, i.e., CH_4/H_2/Ar and Cl_2/Ar, were compared for the etching of InGaP, AlInP, and AlGaP under inductively coupled plasma (ICP) conditions. While the etching with CH_4/H_2/Ar discharges appears to be ion driven, Cl_2/Ar discharges showed an additional strong chemical enhancement. The highest etch rate (#approx#1 #mu#m/min) for InGaP was achieved at high ICP source power (#>=#750 W) with the Cl_2/Ar chemistry. Cl_2/Ar discharges provided very smooth surfaces in all three materials with root-mean-square roughness measured by atomic force microscopy around 2 nm. This result may be due to the efficient ion-assisted product desorption in this chemistry. The etched near-surface region of InGaP (#approx#100 Angstrom) with Cl_2/Ar maintained almost the same stoichiometry as that of the unetched control. By contrast, the CH_4/H_2/Ar plasma chemistry produced somewhat rougher surfaces and depletion of phosphorous (P) from the ...

1998-05-01

126

Probable role of trace elements of some medicinal plants in cardio-vascular diseases  

International Nuclear Information System (INIS)

A number of herbal drugs are used in the Unani (Greco-Arab) System of Medicine for cardiovascular diseases. The herbs were analyzed by flame AAS and ICP-AES to determine if their therapeutic actions can be associated with the elements present in them. Cadmium, cobalt, chromium, copper, iron, potassium, magnesium, manganese, sodium, nickel, phosphorus, lead and zinc were some of the elements which play various roles in cardiovascular affections. An effort was made to correlate the role of these elements in cardiac diseases. (Auth.). 2 tabs., 32 refs.

127

Antioxidant treatment with quercetin ameliorates erectile dysfunction in streptozotocin-induced diabetic rats.  

Science.gov (United States)

Oxidative stress is demonstrated to be involved in the pathophysiological mechanism of erectile dysfunction (ED). Quercetin, a potent bioflavonoid, has been reported to have the antioxidant role. In the present study, we examined the effect of quercetin on ED and oxidative stress in streptozotocin (STZ)-induced diabetic rats. Diabetes was induced in Sprague-Dawley rats with a single intravenous injection of STZ. The diabetic rats were then randomized to diabetic group and quercetin therapy groups which were treated with quercetin at different doses of 5, 20 and 50mg/kg per day respectively. At the end of the 8th week, erectile function was assessed by measuring the rise in intracavernous pressure (ICP) following cavernous nerve electrostimulation. Superoxide dismutase (SOD) activity, thiobarbituric acid-reacting substance (TBARS) and nitrite and nitrate (NOx) levels were measured in cavernosum tissue. Endothelial NO synthase (eNOS) expression was determined using ...

2011-06-14

128

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

129

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

130

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

131

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

132

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

133

Final Technical Report  

Energy Technology Data Exchange (ETDEWEB)

Installation of new Shortwave Spectrometer for permanent operation at SGP - In May 2006 the new ShortWave Spectrometer (SWS) was installed in the Optical Trailer at the Southern Great Plains Central Facility SGP on 27 April 2006. The SWS began full operation 28 April 2006 and has run continuously to the present. Over 25 GB of spectra has been collected, calibrated and archived. 3-D radiative transfer simulations - Retrieved fields of cloud optical thickness and effective radius to from the MODIS Airborne Simulator were used to reproduce 3D cloud fields that were used a input to 3D radiative transfer simulations and then compared with simultaneous Solar Spectral Flux Radiometer (SSFR) spectral irradiance measurements. The influence of both horizontal and vertical cloud structure, using accurate versus approximated optical properties in the radiative transfer model on the modeled irradiance was examined, as was the influence of using the full ...

2009-05-26

134

MEMS-based Speckle Spectrometer  

CERN Document Server

We describe a new concept for a MEMS-based active spatial filter for astronomical spectroscopy. The goal of this device is to allow the use of a diffraction-limited spectrometer on a seeing limited observation at improved throughput over a comparable seeing-limited spectrometer, thus reducing the size and cost of the spectrometer by a factor proportional to r0/D (For the case of a 10 meter telescope this size reduction will be approximately a factor of 25 to 50). We use a fiber-based integral field unit (IFU) that incorporates an active MEMS mirror array to feed an astronomical spectrograph. A fast camera is used in parallel to sense speckle images at a spatial resolution of lambda/D and at a temporal frequency greater than that of atmospheric fluctuations. The MEMS mirror-array is used as an active shutter to feed speckle images above a preset intensity threshold to the spectrometer, thereby increasing ...

2006-01-01

135

A Bragg curve ionization chamber for acceleration mass spectrometry  

CERN Document Server

A Bragg curve ionization chamber for acceleration mass spectrometry

1985-01-01

136

The Micro-X Imaging Spectrometer Instrument  

Science.gov (United States)

The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.

2010-01-01

137

Results from a Prototype Chicane-Based Energy Spectrometer for a Linear Collider  

Energy Technology Data Exchange (ETDEWEB)

The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.

2011-02-28

138

Multi-GeV electron spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...

2010-11-11

139

Measurement of fission cross sections for nuclear transmutation on Am-241, Am-242m and Am-243 using lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)

1997-12-31

140

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.

1998-08-01

141

Measurement of fission cross sections for Am-241, Am-242m and Am-243 with linac-driven lead slowing-down spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)

1999-02-01

142

Diode laser overtone spectroscopy of CO_2 at 780nm  

International Nuclear Information System (INIS)

Overtone absorption lines of "1"2C"1"6O_2 have been examined by using a tunable diode laser (TDL) spectrometer in the region around 12770cm"-"1. The spectrometer sources are commercially available double heterostructure InGaAlAs TDLs operating in the 'free-running' mode, which allowed the detection of the line positions within 0.01cm"-"1. The observed carbon dioxide absorption lines belong to the #nu#_1+5#nu#_3 ro-vibrational band with rotational quantum number J up to 48. The minimum absorbance detected by the spectrometer (#approx#5x10"-"6) permitted to observe the weakest lines having the absorption cross section of the order of #approx#1x10"-"2"7cm"2/molecule.

2005-12-01

143

Apparatus for measuring the decontamination factor of a multiple filter air-cleaning system  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement ...

1985-07-03

144

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-09-01

145

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

146

Spherically bent crystal spectroscopy in laser-produced plasma  

International Nuclear Information System (INIS)

A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from ...

2008-02-01

147

Revision I July 29, 2009 - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

MIL-STD-129. N. 5/15/97. Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 ...

148

Project Technical ... - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 D. Notice 1. 12/15/99. 05/10/ 02 ...

149

AMS Project Plan - Alpha Magnetic Spectrometer - NASA  

Science.gov (United States)

Feb 19, 2009 ... Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1. D. Notice 1 ...

150

A new analysis for membrane noise. The integral spectrum.  

UK PubMed Central (United Kingdom)

A new method of random data analysis has been developed with special implications for membrane noise. The integral spectrometer uses overlapping broad-band filters of simple design, whose bandwidth...Full Text Available

1976-07-01

151

Variable-dispersion electron spectrometer for the SCA/FEL  

International Nuclear Information System (INIS)

A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.

1989-06-01

152

Results from a Bragg Curve Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-01-01

153

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.

1984-10-22

154

Polarized triple-axis spectrometer TASP  

Energy Technology Data Exchange (ETDEWEB)

The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.

1996-11-01

155

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

156

Large solid angle Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A conical Bragg-curve spectrometer (BCS) has been constructed. The outer case was a molded plastic cone. Printed circuit techniques were used to form an insert with inscribed equipotentials to approximate a 1/r/sup 2/ electric field shape. The charge and energy resolution were measured for elastically scattered beams of 206 MeV /sup 28/Si, 413 and 378 MeV /sup 56/Fe, and 670 MeV /sup 86/Kr ions. Performance of this detector, particularly its charge resolution, is discussed with respect to variation in solid angle.

1984-02-01

157

In-place testing of HEPA filter systems by the single-particle, particle-size spectrometer method  

Energy Technology Data Exchange (ETDEWEB)

This standard describes the procedure and equipment for in-place testing of HEPA filter systems by the single-particle, particle-size (SPPS) spectrometer method. This method provides the capability for evaluating the effectiveness (i.e., decontamination factor or DF) of systems consisting of one or more stages of HEPA filters against submicrometer aerosols in discrete particle-size ranges. It is particularly useful for testing of multi-stage HEPA filter installations and for testing of very large (50,000 cfm installed capacity) single-stage systems where it is desired to minimize the quantity of challenge aerosol required.

1981-12-01

158

Application of the digital waveform analysis to Bragg curve spectrometer  

International Nuclear Information System (INIS)

Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)

2004-11-01

159

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

160

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

161

Observation of Fluorescence for some lanthanides in LiCl-KCl molten salt media at high temperature  

Energy Technology Data Exchange (ETDEWEB)

To our knowledge, the fluorescence studies of lanthanides in LiCl-KCl eutectic molten salt at a high temperature are not reported yet. The fluorescence of the lanthanide-ions was generally decreased when the temperature was increased. Moreover, the fluorescence of the lanthanides was strong when the sample was solidified to or from the melt. The temperature, where the fluorescence was decreased, was identified to be different depending on the species of the lanthanides and the substrates was considered to possibly be from quenching of the fluorescence due to either the collisions of melted samples induced by high temperature media or the re-absorption of fluorescence by the samples. Several comparison experiments were performed to explain and understand this phenomenon and improve the fluorescence. In this way, an on-line monitoring of chemical species and the concentration for lanthanides elements in molten salt media of pyrochemical process can be accomplished, and it can replace the ...

2008-08-15

162

Investigation of the sample characteristics needed for the determination of the origin of uranium-bearing materials  

International Nuclear Information System (INIS)

A set of 35 uranium ore and 10 yellow cake samples, collected worldwide from different mines and production sites, were analyzed for their impurity spectrum by ICP-MS. Pattern recognition techniques such as cluster analysis were applied to the data set in order to characterize samples with relation to their geographical origin. The results obtained show a clear relationship between samples taken from the same geological origin and constitute a satisfactory fingerprint for establishing the origin of the material. In addition to the impurity data, data on the isotopic composition of radiogenic lead is used to resolve ambiguity when impurity cluster analysis fails to deliver unambiguous origin data. (author)

2008-10-01

163

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated ...

1999-11-01

167

Simultaneous estimation of trace and toxic metals through drinking water from Tarapur using ICP-AES  

International Nuclear Information System (INIS)

In the present paper the contamination levels of trace and toxic metals in drinking water collected from Tarapur industrial area, Thane were investigated. The concentrations of trace and toxic metals (Pb, Cd, Cu, Cr, Ni, Se, V, Zn, Mn, Mo, Co, As and Ba) were determined simultaneously using Inductively Coupled Plasma Atomic Emission Spectrometry (ICP-AES). The results were compared with international water quality guidelines (WHO, 2008) and were found within the permissible limits. The quality assurance was checked by standard addition method and spike recovery. The concentration of Pb, Cd, Cu, Cr, Ni, Se, V, Zn, Mn, Mo, Co, As and Ba varies from 4.25-19.62 #mu#g/L, 0.13-1.49 #mu#g/L, 0.60-65.55 #mu#g/L, 0.46-4.15 #mu#g/L, <0.1 #mu#g/L, 0.5- 9.35 #mu#g/L, <0.5 #mu#g/L, 3.41-99.64 #mu#g/L, 0.80-9.62 #mu#g/L, 0.30-1.48 #mu#g/L, <0.1-0.90 #mu#g/L, <0.63 #mu#g/L and 0.71-9.0 #mu#g/L respectively. Similarly Na, K, Ca and Mg varies from 8.83-61.54 mg/L, ...

2010-05-13

168

Precious metal enrichment in the Platreef, Bushveld Complex, South Africa: evidence from homogenized magmatic sulfide melt inclusions  

Science.gov (United States)

Magmatic sulfide deposits are the most significant source of platinum-group elements (PGE) in the world. Key to understanding their genesis is determining the processes and timing of sulfide saturation, metal enrichment and crustal contamination. In this study, we have identified droplets of magmatic sulfide from the Platreef, South Africa, where droplets of sulfide have been trapped in the earliest crystallising phase, chromite. Due to their early entrapment at high temperatures, metal concentrations and ratios that they display are indicative of a very early-stage sulfide liquid in the system, as they will have cooled and fractionated within an essentially closed system, unlike interstitial blebs that crystallise in an open system as the magma cools. Analysis of these droplets in an opaque mineral like chromite by LA-ICP-MS is problematic as some of the fractionated inclusion is necessarily lost during cutting and polishing to initially identify the inclusion. ...

2011-06-01

169

Influence of pH on the passivation behavior of 254SMO stainless steel in 3.5% NaCl solution  

Energy Technology Data Exchange (ETDEWEB)

The potentiodynamic polarization measurement of 254SMO stainless steel (UNS 31254) was conducted in 3.5% NaCl solutions with pH ranging from 0.1 to 5. The results indicated that this stainless steel offered excellent pitting corrosion resistance in corrosive environments. Further, it also exhibited various features on the polarization curves in different pH solutions. The electrochemical constant-potential passivation treatment performed at different pH followed by XPS analysis revealed that the primary constituents of the outermost layer of the passive films formed in the weak (pH 5) and strong (pH 0.8) acid solutions are iron oxides and Cr{sub 2}O{sub 3} and Cr(OH){sub 3}, respectively. Molybdenum oxides, primarily in the six-valence state, existed in the outermost layer of the passive film. Only very weak signals corresponding to that of nickel oxides were detected in the film formed in the weak acid (pH 5) solution. The ICP-MS analyses indicated selective ...

2007-05-15

170

Influence of pH on the passivation behavior of 254SMO stainless steel in 3.5% NaCl solution  

International Nuclear Information System (INIS)

The potentiodynamic polarization measurement of 254SMO stainless steel (UNS 31254) was conducted in 3.5% NaCl solutions with pH ranging from 0.1 to 5. The results indicated that this stainless steel offered excellent pitting corrosion resistance in corrosive environments. Further, it also exhibited various features on the polarization curves in different pH solutions. The electrochemical constant-potential passivation treatment performed at different pH followed by XPS analysis revealed that the primary constituents of the outermost layer of the passive films formed in the weak (pH 5) and strong (pH 0.8) acid solutions are iron oxides and Cr_2O_3 and Cr(OH)_3, respectively. Molybdenum oxides, primarily in the six-valence state, existed in the outermost layer of the passive film. Only very weak signals corresponding to that of nickel oxides were detected in the film formed in the weak acid (pH 5) solution. The ICP-MS analyses indicated selective dissolution of a ...

2007-05-01

171

DEVELOPMENT OF MONOSODIUM TITANATE (MST) PURCHASE SPECIFICATIONS  

Energy Technology Data Exchange (ETDEWEB)

Savannah River National Laboratory (SRNL) evaluated the previous monosodium titanate (MST) purchase specifications for particle size and strontium decontamination factor. Based on the measured particle size and filtration performance characteristics of several MST samples with simulated waste solutions and various filter membranes we recommend changing the particle size specification as follows. The recommended specification varies with the size and manufacturer of the filter membrane as shown below. We recommend that future batches of MST received at SRS be tested for particle size and filtration performance. This will increase the available database and provide increased confidence that particle size parameters are an accurate prediction of filtration performance. Testing demonstrated the feasibility of a non-radiochemical method for evaluating strontium removal performance of MST samples. Using this analytical methodology we recommend that the purchase specification include the ...

2006-04-30

172

Comparison of plasma chemistries for inductively coupled plasma etching of InGaAlP alloys  

Science.gov (United States)

Two plasma chemistries, i.e., CH{sub 4}/H{sub 2}/Ar and Cl{sub 2}/Ar, were compared for the etching of InGaP, AlInP, and AlGaP under inductively coupled plasma (ICP) conditions. While the etching with CH{sub 4}/H{sub 2}/Ar discharges appears to be ion driven, Cl{sub 2}/Ar discharges showed an additional strong chemical enhancement. The highest etch rate ({approximately}1 {mu}m/min) for InGaP was achieved at high ICP source power ({ge}750 W) with the Cl{sub 2}/Ar chemistry. Cl{sub 2}/Ar discharges provided very smooth surfaces in all three materials with root-mean-square roughness measured by atomic force microscopy around 2 nm. This result may be due to the efficient ion-assisted product desorption in this chemistry. The etched near-surface region of InGaP ({approximately}100 {Angstrom}) with Cl{sub 2}/Ar maintained almost the same stoichiometry as that of the unetched control. By contrast, the CH{sub 4}/H{sub 2}/Ar plasma chemistry produced ...

1998-05-01

173

Analysis of impurities in beryllium, affecting evaluation of the tritium breeding ratio  

International Nuclear Information System (INIS)

In most conceptual fusion power reactor designs, it is proposed to use beryllium as a neutron multiplier in the blanket. Detailed chemical composition of beryllium is necessary for evaluation of the tritium breeding ratio, and estimating the activation and transmutation of beryllium in the fusion reactor. In the present report, special attention was paid to a detailed analysis of impurities in beryllium, relevant to the tritium breeding ratio evaluation. Two different methods were used for the study of impurities: an analysis of the local sample by the ICP-MS method, and an integral analysis of the beryllium assembly, using the pulsed neutron method. The latter method was proposed as the most effective way of analyzing the integral effect to impurities in beryllium on production of the tritium on the lithium-6. The evaluation of the integral effect was based on time behaviour observations of the thermal neutron flux, following the injection of a burst of D-T ...

174

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been ...

2007-01-01

175

Feasibility study of large combined function magnets for the Jefferson lab 12 GeV upgrade  

CERN Document Server

The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm iron design has been selected and analyzed. These low current densities are ...

2005-01-01

176

An overview on the study of quark gluon plasma with Alice dimuon spectrometer; Apercu sur l'etude du plasma de Quarks et de gluons a l'aide du spectrometre dimuons d'Alice  

Energy Technology Data Exchange (ETDEWEB)

The Alice experiment is one of the four main LHC (Large Hadron Collider) experiments. It is dedicated to the study of a new state of matter: the quark gluon plasma, where quarks and gluons are no longer confined within hadrons. In this document, the physics issues that led to the construction of Alice dimuon spectrometer, are described. Then, the research and development on the dimuon spectrometer is presented. The different absorbers are described and experimental tests used to determine their dimensions are presented. The dimuon trigger built using the RPC (Resistive Plate Chamber) streamer mode is then described along with the associated beam and cosmic tests and results. Finally, the tracking system is described in detail and more particularly all its electronics and the first station. The physics constraints on the expected performances of all these systems are clearly defined. (author)

2007-10-15

177

Testing measurements at horizontal channels of the MARIA reactor performed using neutron spectrometers; Pomiary testowe przy kanalach poziomych reaktora MARIA wykonane przy uzyciu spektrometrow neutronow  

Energy Technology Data Exchange (ETDEWEB)

By means of neutron diffraction, using the standard polycrystalline sample of Al{sub 2}O{sub 3}, measurements on three (of four spectrometers) already installed in the front of horizontal channels of MARIA reactor have been performed. Basing on these experiments as well as on activation measurements carried out earlier, the fluxes of monoenergetic neutrons have been estimated. These experiments allowed to determine (for a given geometry and kind of monochromators chosen) the resolution efficiency of instruments and high order contamination in the reflected beam. With the help of polycrystalline vanadium and TbBr{sub 3} sample, the possibility of studies using the inelastic scattering process have been tested. (author) 7 refs, 15 figs, 7 tabs

1997-12-31

178

Surface analysis by Fourier-transform infrared (FTIR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.

1981-08-12

179

Results from a Bragg Curve Spectrometer  

International Nuclear Information System (INIS)

The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is proportional to the specific ionization along the track. The preamp output is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. Several versions of the BCS have been constructed and tested. Test results, detector characteristics and some design problems are discussed.

1984-10-01

180

Measurement of the relaxation time of hot electrons in laser-solid interaction at relativistic laser intensities  

Energy Technology Data Exchange (ETDEWEB)

The authors have measured the relaxation time of hot electrons in short pulse laser-solid interactions using a picosecond time-resolved x-ray spectrometer and a time-integrated electron spectrometer. Employing laser intensities of 10{sup 17}, 10{sup 18}, and 10{sup 19} W/cm{sup 2}, they find increased laser coupling to hot electrons as the laser intensity becomes relativistic and thermalization of hot electrons at timescales on the order of 10 ps at all laser intensities. They propose a simple model based on collisional coupling and plasma expansion to describe the rapid relaxation of hot electrons. The agreement between the resulting K{sub {alpha}} time-history from this model with the experiments is best at highest laser intensity and less satisfactory at the two lower laser intensities.

2006-08-22

181

Continuous-wave cavity ringdown spectroscopy of the Formula Not Shown Meinel system (2,1) band  

British Library Electronic Table of Contents (United Kingdom)

The Formula Not Shown system of Formula Not Shown was first observed in auroral emissions by Meinel in 1950. Although the Formula Not Shown band system has been reinvestigated since this first spectral study, no laboratory spectrum of the (2,1) vibronic band has been obtained. We have recently built a continuous-wave cavity ringdown spectrometer, and as a first test of this spectrometer we observed the (2,1) band of Formula Not Shown in a positive column discharge cell. Many lines of the first positive band system of Formula Not Shown were also identified during the process of assigning this spectrum. The relative intensities of the Formula Not Shown and Formula Not Shown bands were found to change with discharge cell pressure, and so each spectral region was observed at two pressures to a...

2008-01-01

182

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

183

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

184

Evolution of the chromospheres and winds of low- and intermediate-mass giant stars  

International Nuclear Information System (INIS)

Results are presented of an empirical analysis of the global thermodynamical requirements of the winds in the outer atmospheres of a representative sample of red giant stars of low- and intermediate-mass range. Results indicate that the mass-loss rates in these stars are not strongly dependent on the actual physical processes driving the winds. It is suggested that nonlinear processes act to regulate wind energy fluxes. Possible mechanisms responsible for the chromospheric heating and the mass loss in the low- and intermediate-mass giant stars are discussed. 151 refs.

185

Synthesis and characterization of Al{sub 2}O{sub 3}/ZrO{sub 2}, Al{sub 2}O{sub 3}/TiO{sub 2} and Al{sub 2}O{sub 3}/ZrO{sub 2}/TiO{sub 2} ceramic composite particles prepared by ultrasonic spray pyrolysis  

Energy Technology Data Exchange (ETDEWEB)

Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.

2002-08-01

186

Synthesis and characterization of Al_2O_3/ZrO_2, Al_2O_3/TiO_2 and Al_2O_3/ZrO_2/TiO_2 ceramic composite particles prepared by ultrasonic spray pyrolysis  

International Nuclear Information System (INIS)

Fine ceramic particles of zirconia toughened alumina (ZTA), titania toughened alumina (TTA), and zirconia-titania toughened alumina (ZTTA) have been synthesized by ultrasonic spray pyrolysis (USP) at various temperatures from starting salt solutions of various compositions aiming for the development of catalytic material. These particles were characterized for properties such as shape, size and size distribution, diffraction pattern, and chemical and phase composition of elements by scanning electron microscopy (SEM), particle size analyzer (PSA), x-ray diffraction (XRD), and inductively coupled plasma-atomic emission spectroscopy (ICP-AES). Chemical compositions and sizes of ceramic composites have been controlled by the stoichiometry of salt solutions and the flow rate of spraying solutions. The optimum experimental conditions for the various composite particle synthesis have been proposed.

2002-08-01

187

Specific adsorption of arsenic and humic acid on Pt and PtO films  

International Nuclear Information System (INIS)

A study of specific adsorption of arsenic (As) and humic acid (HM) onto Pt and PtO films using cyclic voltammetry and cyclic massogram in 0.5-M H_2SO_4 is presented, which may serve as an alternative to studies involving specific adsorption of these species on soil minerals. Adsorption of As is normally evaluated by conducting batch adsorption experiments, followed by analysis using hydride-generation atomic absorption spectrophotometry (HGAA) or inductively coupled plasma-optical emission spectrometry (ICP-OES). We found that specific adsorption of As and HM depends both on the surface and on these species present in the adsorption solution. HM does not desorb previously adsorbed As at the HM concentrations used in the present study, but it does co-adsorb with As from a 1 x 10"-"6-M aqueous solution of As_2O_3 containing 1 mg of carbon L"-"1 HM. Arsenic adsorbs strongly on Pt in the presence of HM or during sequential specific adsorption with HM.

2010-07-01

188

Recovery of lanthanides and yttrium from red mud by selective leaching  

Energy Technology Data Exchange (ETDEWEB)

This study presents a rapid and selective method for the recovery of lanthanides and yttrium, existing in economically interesting concentrations, from red mud, the byproduct of the alumina production. The leaching process is based on the extraction of these elements with diluted nitric acid from red mud under moderate conditions and without using any preliminary treatment. Several parameters such as leaching agents, contact time, temperature, pressure and solid to liquid ratio were investigated in order to achieve an optimum recovery. The process followed here was selected taking into account its efficiency for the selective recovery of yttrium and lanthanides, but also its suitability for the subsequent liquid-liquid extraction of the leaching solution for the separation of the individual lanthanides. The achieved recovery percentages were for Y about 90%, for the investigated heavy lanthanides (Dy, Er, Yb) up to 70%, for the middle ones (Nd, Sm, Eu, Gd) up to 50% and for the group ...

1996-01-30

189

Recovery of lanthanides and yttrium from red mud by selective leaching  

International Nuclear Information System (INIS)

This study presents a rapid and selective method for the recovery of lanthanides and yttrium, existing in economically interesting concentrations, from red mud, the byproduct of the alumina production. The leaching process is based on the extraction of these elements with diluted nitric acid from red mud under moderate conditions and without using any preliminary treatment. Several parameters such as leaching agents, contact time, temperature, pressure and solid to liquid ratio were investigated in order to achieve an optimum recovery. The process followed here was selected taking into account its efficiency for the selective recovery of yttrium and lanthanides, but also its suitability for the subsequent liquid-liquid extraction of the leaching solution for the separation of the individual lanthanides. The achieved recovery percentages were for Y about 90%, for the investigated heavy lanthanides (Dy, Er, Yb) up to 70%, for the middle ones (Nd, Sm, Eu, Gd) up to 50% and for the group ...

190

Modified Fragmentation Function in Heavy Ion Collisions at RHIC via Direct photon-Jet Measurements  

CERN Document Server

The presented results are the first measurements at RHIC for direct $\\gamma$-charged hadron azimuthal correlations in heavy ion collisions. We use these correlations to study the color charge density of the medium through the medium-induced modification of high-p$_T$ parton fragmentation. Azimuthal correlations of direct photons at high transverse energy (8 $<$ p$_T$ $<$ 16 GeV) with away-side charged hadrons of transverse momentum (3 $<$ p$_T$ $<$ 6 GeV/c) have been measured over a broad range of centrality for $Au+Au$ collisions and $p+p$ collisions at $\\sqrt{s_{NN}}$ = 200 GeV in the STAR experiment. A transverse shower shape analysis in the STAR Barrel Electromagnetic Calorimeter Shower Maximum Detector is used to discriminate between the direct photons and photons from the decays of high p$_T$ $\\pi^{0}$. The per-trigger away-side yield of direct $\\gamma$ is smaller than from $\\pi^{0}$ trigger at the same centrality class. Within the current uncertainty the ...

2008-01-01

191

Management of pitfalls for the successful clinical use of hypothermia treatment.  

Science.gov (United States)

Therapeutic hypothermia is a promising method for controlling intracranial pressure (ICP) in severely brain-injured patients. However, clinical data regarding the effect of brain hypothermia on overall outcome of these patients is limited. This may be because there are specific pitfalls associated with the clinical management of induced hypothermia in patients with severe traumatic brain injury (TBI). These pitfalls may be avoided by preventing specific risk factors when cooling is induced and with rewarming. However, these risk factors have not been well systematically discussed in the literature. In this paper, three categories of clinical issues regarding the management of brain hypothermia are discussed: (1) stress-induced secondary brain injury mechanisms; (2) technical aspects of intensive care unit (ICU) cooling management; and (3) rewarming rates and methods. For patients with a Glasgow Coma Scale (GCS) score of less than 8, management of stress-induced ...

2009-03-01

192

Influence of residual K{sup +} on the catalytic performance of CuO-CeO{sub 2} catalysts in preferential oxidation of CO in excess hydrogen  

Energy Technology Data Exchange (ETDEWEB)

Influence of residual K{sup +} on the preferential oxidation of CO in excess hydrogen (PROX) over CuO-CeO{sub 2} catalysts was investigated. CuO-CeO{sub 2} catalysts were characterized by BET, ICP, XRD, UV-Raman and TPR techniques. The results showed that the existence of residual K{sup +} made {alpha} peak in TPR of CuO-CeO{sub 2} catalysts shift to higher temperatures and depressed the PROX in the absence of CO{sub 2} and H{sub 2}O in the feed over CuO-CeO{sub 2} catalysts. However, small amount of residual K{sup +} was beneficial to the catalytic performance of CuO-CeO{sub 2} catalysts in the PROX in the presence of CO{sub 2} and H{sub 2}O in the feed. Consequently, residual K{sup +} with an appropriate content was beneficial to improve the catalytic performance of CuO-CeO{sub 2} catalysts in the presence of CO{sub 2} and H{sub 2}O. (author)

2008-01-15

193

Hydrolysis kinetics of lead silicate glass in acid solution  

International Nuclear Information System (INIS)

Hydrolysis kinetics of the lead silicate glass (LSG) with 40 mol% PbO in 0.5 N HNO_3 aqueous acid solution was investigated. The surface morphology and the gel layer thickness were studied by scanning electron microscopy (SEM) micrographs. Energy dispersive X-ray spectroscopy (EDS) and inductively coupled plasma spectroscopy (ICP) were used to determine the composition of the gel layer and the aqueous solution, respectively. The silicon content of the dissolution products was determined by using weight-loss data and compositions of the gel layer and the solution. The kinetic parameters were determined using the shrinking-core-model (SCM) for rate controlling step. The activation energy obtained for hydrolysis reaction was Q_c_h_e = 56.07 kJ/mole. The diffusion coefficient of the Pb ions from the gel layer was determined by using its concentration in solution and in LSG. The shrinkage of the sample and the gel layer thickness during dissolution process were ...

2009-06-01

194

Functionalizing titania nanoparticle surfaces in a fluidized bed plasma reactor  

International Nuclear Information System (INIS)

Functionalizing nanoparticle surfaces is essential for achieving homogeneous dispersions of monodisperse particles in polymer nanocomposites for successful utilization in engineering applications. Functionalization reduces the surface energy of the nanoparticles, thereby limiting the tendency to agglomerate. Moreover, reactive groups on the surface can also participate in the polymerization, creating covalent bonds between the inorganic and organic phases. In this paper, a fluidized bed inductively coupled plasma (FB-ICP) reactor is used to break apart the agglomerates and functionalize commercial TiO2 nanoparticle powders in a batch of several grams. The fluidized bed could be implemented into a continuous flow reactor, potentially making this a viable method to treat larger quantities of commercial powders. The particles are treated with acrylic acid (AA) and tetraethylorthosilicate (TEOS) plasma and the functionalized particles were collected separately from ...

2009-11-18

195

On the dependence of some helium shell flash characteristics on core mass  

Energy Technology Data Exchange (ETDEWEB)

A theoretical derivation of the intershell mass--core mass relation of Paczynski is attempted. Formulae developed by Sugimoto and Fujimoto are extended to less massive (m/sub c/< or approx. =1) cores.

1980-08-15

196

The PAMELA space mission  

Energy Technology Data Exchange (ETDEWEB)

The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.

2009-03-15

197

Survey of naturally radioactive level of some new type wall materials  

International Nuclear Information System (INIS)

Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)

2006-09-01

198

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

199

Spectroscopic detection  

Energy Technology Data Exchange (ETDEWEB)

In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.

2003-01-01

200

Some optimization measurements and parameters of a radionuclide X-ray fluorescence spectrometer  

International Nuclear Information System (INIS)

An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.

1986-01-01

201

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

202

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

203

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

204

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

205

On the Metastable Level in Ni-like Ions  

Energy Technology Data Exchange (ETDEWEB)

The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.

2004-09-14

206

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

207

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

208

Heavy metals in welding fumes  

Energy Technology Data Exchange (ETDEWEB)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.

1984-10-01

209

Heavy metals in welding fumes  

International Nuclear Information System (INIS)

Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).

1984-01-01

210

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

211

Final Report: Planetary Instrument Definition and Design Program (PIDDP) Support Project  

Energy Technology Data Exchange (ETDEWEB)

The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.

1999-03-01

212

Cylindrical drift chamber with three-dimensional data readout  

International Nuclear Information System (INIS)

A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.

213

Cylinder drift chamber with three-dimensional data output  

Science.gov (United States)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

1995-03-01

214

Cylinder drift chamber with three-dimensional data output  

International Nuclear Information System (INIS)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

215

Coulomb Repulsion in Miniature Ion Mobility Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.

1999-08-08

216

Comprehensive, nonintercepting electron-beam diagnostics using spontaneous emission  

Energy Technology Data Exchange (ETDEWEB)

Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.

1989-01-01

217

Chemical effects on L_#gamma#_1/L_#beta#_1 x-ray intensity ratio of molybdenum compounds  

International Nuclear Information System (INIS)

Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).

1987-06-01

218

Application of neural networks to pulse-shape analysis of Bragg curves  

Energy Technology Data Exchange (ETDEWEB)

A novel approach is presented to extract relevant parameters associated with the energy loss of ejectiles from nuclear reactions obtained by digitizing the signals of a Bragg curve spectrometer. New and more powerful computational paradigms allow a more thorough pulse-shape analysis. This is fulfilled using a back-propagation artificial neural network as a pattern identifier. The known problem of over-training is discussed.

2006-01-15

219

An emulation and management software for MCA with 64 independent coded inputs  

International Nuclear Information System (INIS)

A Software for the Neutron Scattering time-of-flight Spectrometer with 64 independent coded inputs is preset. It performs data acquirement and management. The work platform of the software is the Windows 98 and programmed with Visual Basic 6.0. It supports 64 x 1024 channel analyzer computer system. The friendly interface, convenient operation and high reliability are advantages of the Software

2000-09-07

220

Absolute absorption of ozone in the midinfrared  

Energy Technology Data Exchange (ETDEWEB)

The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.

1992-12-20

221

Stellar evolution. II - The evolution of a 3 sun-mass star from the main sequence through core helium burning.  

Science.gov (United States)

Three Sun-mass star evolution from main sequence to helium exhaustion in core, noting chronology of

1965-01-01

222

Mass public health programmes and the obligations of sponsoring and participating organisations  

UK PubMed Central (United Kingdom)

The obligations of organisations associated with policy formation and implementation of international mass public health programmes are explored. Lines of responsibility are considered to become unclear...Full Text Available

2006-10-01

224

Flavor Mixing, Quark Masses, Neutrino Masses and Neutrino Oscillations  

CERN Document Server

We discuss first the flavor mixing of the quarks, using the texture zero mass matrices. Then we study a similar model for the mass matrices of the leptons. We are able to relate the mass eigenvalues of the charged leptons and of the neutrinos to the mixing angles and can predict the masses of the neutrinos. We find a normal hierarchy - the masses are 0.004 eV, 0.01 eV and 0.05 eV. The atmospheric mixing angle is given by the mass ratios of the charged leptons and the neutrinos. we find about 40 degrees, consistent with the experiments. The mixing element, connecting the first neutrino wit the electron, is predicted to be 0.05. This prediction can soon be checked by the Daya Bay experiment.

2009-01-01

225

Calibrating Cosmological Chronometers: White Dwarf Masses ...  

Science.gov (United States)

... The second scenario is limited by the age of our Galaxy such that the lowest-mass WD that could be formed via single star evolution is ~0.47 M ...

2011-05-14

226

What masses for Cepheids  

Science.gov (United States)

To understand the evolution of giant stars, it is important to pin down the masses for Cepheids. The 7- to 10-day bump Cepheids imply lower than evolutionary mass (60%). Recent theoretical work, though, indicates that for Cepheids with periods of 15 to 16 days, the best understanding of the light curves results from using evolutionary masses.

228

Transition probability in "1"7"7Ta  

International Nuclear Information System (INIS)

... energy levels intermediate mass nuclei isotopes nuclei odd-even nuclei

230

Mass-energy spectra of fission fragments in the reaction {sup 242m}Am(n{sub th},f)  

Energy Technology Data Exchange (ETDEWEB)

The mass-energy spectra of the fragments of thermal fission of {sup 242m}Am are measured using the time-of-flight technique. The resulting mass-yield curve and peak-to-valley ratio agree with radiochemical data. The parameters of the kinetic energy distribution of the fragments are determined for the first time. Data on the fine structure of mass spectra in the region of cold fragmentation are presented. 15 refs., 4 figs.

1994-12-01

231

Life of the stars  

Energy Technology Data Exchange (ETDEWEB)

Stars and star evolution are discussed, including supernovae, nucleosynthesis, and mass-luminosity and Hertzsprung--Russell diagrams./aip/.

1988-09-20

234

Numerical and semi-analytic core mass distributions in supersonic isothermal turbulence  

CERN Document Server

We investigate the influence of the turbulence forcing on the mass distributions of gravitationally unstable cores by postprocessing data from simulations of non-selfgravitating isothermal supersonic turbulence with varying resolution. In one set of simulations solenoidal forcing is applied, while the second set uses purely compressive forcing to excite turbulent motions. From the resulting density field, we compute the mass distribution of gravitationally unstable cores by means of a clump-finding algorithm. Using the time-averaged probability density functions of the mass density, semi-analytic mass distributions are calculated from analytical theories. We apply stability criteria that are based on the Bonnor-Ebert mass resulting from the thermal pressure and from the sum of thermal and turbulent pressure. Although there are uncertainties in the application of the clump-finding ...

2010-01-01

235

Negative effective mass below a cut-off frequency  

CERN Document Server

Acoustic metamaterials with negative effective mass below a cut-off frequency are studied. An equivalent mass-spring structure is firstly proposed for such metamaterials, the effective mass is found to follow the Drude model: being negative below a specific frequency. The peculiar behavior is then verified by transmission experiments operating in the low-frequency regime. Inspired by the mass-spring model, we investigate the two-dimensional elastic waveguide with clamped boundaries and attribute the bandgap occurring below a critical frequency to negative effective mass density. The finding helps us to design a new acoustic Drude metamaterial, which enables shearing and bending deformations, in contrast to the membrane-type ones. Both simulation and experimental results show that the proposed metamaterial exhibits negative effective mass below 1200 Hz, thus ...

2010-01-01

236

Measurement of W{sup {+-}} boson mass at LEP by means of DELPHI detector; Mesure de la masse des bosons W{sup {+-}} au LEP a l`aide du detecteur DELPHI  

Energy Technology Data Exchange (ETDEWEB)

The thesis deals with measurement of the mass of the W boson at LEP2, based on the direct reconstruction of its decay products in the hadronic channel. A set of procedures necessary for the extraction of the W mass from the experimental data collected with the DELPHI detector in 1997 was developed (search of optimal variables for the event selection, development of a special method of kinematical reconstruction). The measured value of the mass was interpreted in the framework of the Standard Model, allowing to constrain the mass of the Higgs boson. A substantial part of the work is devoted to systematic effects due to the interactions between the hadronic decay products of the W bosons (colour reconnection and Bose-Einstein correlations), which may significantly influence the measurement of their mass. (author) 53 refs., 104 figs., 33 tabs.

1998-05-25

237

Influence of carbon and nitrogen on corrosion resistance of high purity Fe-50mass% Cr alloys  

International Nuclear Information System (INIS)

High purity Fe-50mass%Cr alloys containing (C+N) in the range of 30 to 500 mass ppm were prepared and their corrosion resistance was investigated. Pitting potential in a 3.5mass%NaCl solution at 343K rose with reducing (C+N) content. Alloys containing (C+N) at less than 100 mass ppm did not sustain pitting corrosion. However, alloys containing 500 mass ppm (C+N) corroded severely in 6%FeCl_3+1/20N HCl solutions. Heat treatment at 923K was recognized as influencing corrosion resistance due to precipitation of carbonitrides only in the case of the alloy containing 500 mass ppm (C+N). (orig.).

238

GENERALIZED ATOMIC MASS LAW  

Science.gov (United States)

Least-squares analyses were performed on a set of atomic masses using standard and generalized senaiempirical mass laws. Presumably because of errors in the assured form of the standand mass law, its least-squares coefficients can be determined at best to an accuracy of about 10%, and masses are predicted with an uncertainty of several Mev/c/sup 2/. The standard mass law was generalized by addition of shell effect and deformation terms. While the least-squares fitting of the generalized mass law is better than for the standard mass law, it is still not possible to predict atomic masses to an accuracy better than a few Mev/c/sup 2/. The nuclear deformations and the well depth . of the nuclear interaction obtained from the additional mass-law terms are in reasonable agreement ...

1959-11-15

239

Accurate evolutions of unequal-mass neutron-star binaries: properties of the torus and short GRB engines  

CERN Document Server

We present new results from accurate and fully general-relativistic simulations of the coalescence of unmagnetized binary neutron stars with various mass ratios. The evolution of the stars is followed through the inspiral phase, the merger and prompt collapse to a black hole, up until the appearance of a thick accretion disk, which is studied as it enters and remains in a regime of quasi-steady accretion. Although a simple ideal-fluid equation of state with \\Gamma=2 is used, this work presents a systematic study within a fully general relativistic framework of the properties of the resulting black-hole--torus system produced by the merger of unequal-mass binaries. More specifically, we show that: (1) The mass of the torus increases considerably with the mass asymmetry and equal-mass binaries do not produce significant tori if they have a total baryonic mass ...

2010-01-01

240

Viscoelastic locally resonant double negative metamaterials with controllable effective density and elasticity  

British Library Electronic Table of Contents (United Kingdom)

A metamaterial that is composed of solid viscoelastic elements with controllable properties is proposed in this Letter. This enables an adaptable and general acoustic metamaterial to be practically realised. An array of masses with a single elastic connection to a supporting viscoelastic structure, such as one that is dynamically equivalent to an array of Helmholtz resonators, only provides a system with negative effective mass. A local active control scheme applied to each of these masses can emulate additional elastic connections to the supporting structure. An array of masses with a suitable local control scheme can provide both the negative effective stiffness and mass required for negative refraction. The tuneable feedback control parameters determine the characteristics of the region...

2010-01-01

241

Nucleon and meson effective masses in the relativistic mean-field theory  

Energy Technology Data Exchange (ETDEWEB)

Nucleon and meson effective masses in the nonlinear relativistic mean-field theory introducing a nonlinear {omega}-{rho} and {sigma} coupling motivated by the quark-meson coupling model is explored. It is shown that, in contrast to the usual Walecka model, not only the effective nucleon mass m{sub eff,N} but also the effective {sigma},{rho} meson masses (m{sub eff{sigma}},m{sub eff,{rho}}) and the effective {omega} meson mass m{sub eff,{omega}} are nucleon density dependent. (author)

2001-10-01

242

Nucleon and meson effective masses in the relativistic mean-field theory  

International Nuclear Information System (INIS)

Nucleon and meson effective masses in the nonlinear relativistic mean-field theory introducing a nonlinear #omega#-#rho# and #sigma# coupling motivated by the quark-meson coupling model is explored. It is shown that, in contrast to the usual Walecka model, not only the effective nucleon mass m_e_f_f_,_N but also the effective #sigma#,#rho# meson masses (m_e_f_f_#sigma#,m_e_f_f_,_#rho#) and the effective #omega# meson mass m_e_f_f_,_#omega# are nucleon density dependent. (author)

2001-10-01

243

Mira variables - Pulsation, mass loss and evolution  

International Nuclear Information System (INIS)

Recent developments in the analysis of Mira atmosphere, the determination of the pulsation mode, the problem of mass loss, and the evolution of the Mira variables are covered. Model atmospheres for Mira variables, including the opacities of the molecules expected in very late M-type atmospheres are discussed. The pulsation constant for Omicron Ceti is evaluated using T(eff) = 2900 + or - 200 K, and it is concluded that Miras are fundamental mode pulsators. The importance of molecular opacity to the driving of mass loss is evaluated, and it is pointed out that the radiation pressure on molecules is not a major factor in driving mass loss from Mira. Mass loss is considered as a factor in the calculations of the periods for Mira variables. 30 refs.

1990-05-28

244

Mass of the nucleon in a chiral quark-diquark model  

International Nuclear Information System (INIS)

The mass of the nucleon is studied in a chiral quark-diquark model. Both scalar and axial-vector diquarks are taken into account for the construction of the nucleon state. After the hadronization procedure is used to obtain an effective meson-baryon Lagrangian, the quark-diquark self-energy is calculated to generate the baryon kinetic term as well as determine the mass of the nucleon. It turns out that both the scalar and axial-vector parts of the self-energy are attractive for the mass of the nucleon. We investigate the range of parameters that can reproduce the mass of the nucleon.

2005-09-01

245

Mass distribution of fission products in the 28.5 MeV alpha particle induced fission of "2"3"2Th  

International Nuclear Information System (INIS)

Mass distribution in 28.5 MeV alpha particle induced fission of "2"3"2Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of "2"3"5U. (orig.).

246

Mass distribution of fission products in the 28. 5 MeV alpha particle induced fission of sup 232 Th  

Energy Technology Data Exchange (ETDEWEB)

Mass distribution in 28.5 MeV alpha particle induced fission of {sup 232}Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of {sup 235}U. (orig.).

1989-01-01

247

A multilayered acoustic hyperlens with acoustic metamaterials  

British Library Electronic Table of Contents (United Kingdom)

The acoustic hyperlens can be realized by an alternating layered structure of water and fluid with negative mass density. Based on this alternating layered principle, we propose that an acoustic metamaterial consisting of three layers in water background can be designed to replace the fluid with negative mass density. The effective mass density and bulk modulus of the system which is composed of acoustic metamaterial and water are functions of the frequency. The effective mass density of such a system is close to the negative mass density of the fluid at a specific frequency; thus an acoustic metamaterial hyperlens can be achieved.

2011-01-01

248

Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft  

Energy Technology Data Exchange (ETDEWEB)

A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built and tested. The results of these test, ...

2004-10-13

249

The magnetic spectrometer PAMELA for the study of cosmic antimatter in space  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.

1995-09-01

250

Synthesis of novel high-voltage cathode material LiCoPO{sub 4} via rheological phase method  

Energy Technology Data Exchange (ETDEWEB)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO{sub 4}. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm{sup -2}. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g{sup -1}, respectively. The better electrochemical property should be ascribed to the better crystallized ...

2010-07-23

251

Synthesis of novel high-voltage cathode material LiCoPO4 via rheological phase method  

International Nuclear Information System (INIS)

For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO4. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm-2. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g-1, respectively. The better electrochemical property should be ascribed to the better crystallized rheological phase ...

2010-07-23

252

Study of degradation diagnosis for low voltage cable aged by thermal and radiation with time domain dielectric spectrometer  

International Nuclear Information System (INIS)

Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider causes of the increases of ...

2000-05-01

253

Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions  

International Nuclear Information System (INIS)

The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical model predictions and non-statistical ...

254

Resent development by the use of neutron induced nuclear reaction  

International Nuclear Information System (INIS)

When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University lead slowing-down ...

1992-01-01

255

Recent neutron scattering work at the University of Lowell  

International Nuclear Information System (INIS)

Neutron elastic and inelastic scattering cross sections of _2_3_8U and _2_3_2Th have been measured at the University of Lowell for states below 1.8 MeV. A time-of-flight (TOF) spectrometer was used. The disc-shaped scatterer was oriented to optimize energy resolutions for 200-to-500-keV neutrons. Neutrons were obtained via the _7Li(p,n)_7Be reaction. Targets were prepared by in-situ evaporation of Li onto a Ta backing. During the evaporation, the target thickness was monitored using a 5-m-flight-path TOF spectrometer; a typical target had a neutron thickness from 8 to 10 keV for Esub(p) = 2.25.MeV. Spectra were analyzed using the unfolding code TINA; standard peak shapes were obtained from codes LAGUE and LAPA. Results obtained will be presented.

1981-11-23

256

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1992-01-01

257

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small ...

1991-10-01

258

Electron momentum spectroscopy of H_2 and D_2: Ionization to ground and excited final states  

International Nuclear Information System (INIS)

The symmetric noncoplanar (e,2e) cross sections (momentum profiles) of H_2 and D_2 for the transitions to the 2p#sigma#_u and 2s#sigma#_g excited ion states have been measured, relative to the ground-state ion transition, using a high-sensitivity multichannel momentum-dispersive electron momentum spectrometer (EMS) at an impact energy of 1200 eV. Newly calculated plane-wave impulse approximation (PWIA) cross sections, based on a full-configuration-interaction H_2 wave function, are compared to the experimental results. These calculations are in better agreement with the experimental results for the transition to the 2s#sigma#_g ion state than the earlier theoretical work of Liu and Smith, Jr. [Phys. Rev. A 31, 3003 (1985)] which has been found to be in error. Nevertheless, significant discrepancies between the relative experimental and theoretical cross sections are observed for the transitions to excited ion states, suggesting a failure of the PWIA description of ...

259

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

Energy Technology Data Exchange (ETDEWEB)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of [Delta][epsilon] = 1.3 [mu]eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T[sub m] (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T[sub m]. Quasielastic broadening in the spectrum at Q = 0.082 A[sup -1] is observed only above 210degC, which is 75degC higher than the T[sub m]. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 [mu]eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

1992-06-01

260

Dynamics of polyethylene studied by high resolution neutron spectrometer LAM-80ET  

International Nuclear Information System (INIS)

We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of #DELTA##epsilon# = 1.3 #mu#eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T_m (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T_m. Quasielastic broadening in the spectrum at Q = 0.082 A"-"1 is observed only above 210degC, which is 75degC higher than the T_m. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 #mu#eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).

261

Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02  

Energy Technology Data Exchange (ETDEWEB)

Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric signals from the Galactic Center. (author)

2004-12-15

262

Atomic beam spectrometer using a LiF analyzer crystal  

International Nuclear Information System (INIS)

An energy analyzer has been constructed and operated in UHV for the purpose of analyzing the energy of neutral atoms scattered from solid surfaces. The analyzer consists of a LiF single crystal located at an angle close to the normal to the sample crystal so that the diffraction pattern obtained by scanning the LiF crystal yields the energy of the scattered atoms. Two designs which have been used are described. The temperature of both sample and analyzer crystal is near 20 K and once cleaned they can be maintained in the state of initial preparation for many weeks. The sample was a (001) Cu surface in this case. Such an energy analyzer can only be used, in most cases, for He atom scattering although Ne atoms could be used if the scattered intensities were adequate. The detector developed in this study is able to detect about 2 x 10"5 atoms/s. The resolution of the spectrometer depends on the incident energy of the atom and is about 1 meV at an incident energy of 23 ...

1978-01-01

263

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative ...

264

Masses of Neutron Stars in High-Mass X-ray Binaries with Optical Astrometry  

CERN Document Server

Determining the type of matter that is inside a neutron star (NS) has been a long-standing goal of astrophysics. Despite this, most of the NS equations of state (EOS) that predict maximum masses in the range 1.4-2.8 solar masses are still viable. Most of the precise NS mass measurements that have been made to date show values close to 1.4 solar masses, but a reliable measurement of an over-massive NS would constrain the EOS possibilities. Here, we investigate how optical astrometry at the microarcsecond level can be used to map out the orbits of High-Mass X-ray Binaries (HMXBs), leading to tight constraints on NS masses. While previous studies by Unwin and co-workers and Tomsick and co-workers discuss the fact that the future Space Interferometry Mission should be capable of making such measurements, the current work describes detailed simulations for 6 HMXB ...

2010-01-01

265

Double core evolution. IV - The late stages of evolution of a 2-solar mass red giant with a 1-solar mass companion  

International Nuclear Information System (INIS)

The paper reports on the results of hydrodynamical simulations of the late phase of the common envelope stage of a binary consisting of a 2-solar mass red giant and a 1-solar mass main-sequence companion. The numerical results demonstrate that sufficient energy is released from the orbit to eject the mass within the common envelope without requiring the main-sequence companion to spiral into the white dwarf core of the red giant star. At the end of the simulation the orbital decay time scale increases rapidly to more than 160 yr. The long decay time scale reflects the removal of mass from the common envelope and its subsequent spin-up to near corotation. The ratio of the orbital decay time scale to the mass-loss time scale from the common envelope increases to more than 700, and the mass contained within the common envelope decreases to about 0.01 solar ...

266

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

267

Spectroscopy of neutron-rich Fe isotopes populated in the "6"4Ni+"2"3"8U reaction  

International Nuclear Information System (INIS)

The neutron-rich Fe isotopes from A=61 to 66 were studied through multinucleon transfer reactions by bombarding a "2"3"8U target with a 400 MeV "6"4Ni beam. Unambiguous identification of prompt #gamma# rays belonging to each nucleus was achieved using coincidence relationships with the ions detected in a high-acceptance magnetic spectrometer. The new data extend our knowledge of the level structure of Fe isotopes, which is discussed in terms of the systematics of the region and compared with large-scale shell-model calculations.

2007-09-01

268

Spectra of positrons and electrons emitted in "8"8Y decay  

International Nuclear Information System (INIS)

The "8"8Y decay has been studied with the aim to discover emission of monohromatic positrons (MP). The "8"8Sr(d,2N) reaction was used for production of "8"8Y (#beta#"+, Tsub(1/2)=106.6 days) nuclides. The prismatic beta spectrometer has been used to measure spectra of electrons and positrons. No MPs have been found. The resulting upper bound for their emission rate turned out to be lower than theoretically expected one.

269

Soil gamma ray spectrometry of the Buquira river basin, SP, Brazil; Gamametria de solos da bacia do rio Buquira, SP, Brazil  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactivity found in rocks and its evaluation been frequently used for studies of environmental geochemistry, particularly those of detection and control of pollutants and the consequent changes in environment after antropic interferences. In this work natural radioactivity in forty nine soil samples in the basin of Buquira river, at the Northeast region of Sao Paulo State, has been analysed and measured with a Ge-HP gamma ray spectrometer. A table with the most relevant results found in rocks is shown and discussed. (author)

2002-12-01

270

Search for K_S K_S in J/psi and psi(2S) decays  

CERN Document Server

The CP violating processes J/psi-->K_S K_S and psi(2S)-->K_S K_S are searched for using samples of 58 million J/psi and 14 million psi(2S) events collected with the Beijing Spectrometer at the Beijing Electron Positron Collider. No signal is observed, and upper limits on the decay branching ratios are determined to be BR(J/psi-->K_S K_S) K_S K_S) < 4.6x10^{-6} at the 95% confidence level.

2004-01-01

271

Remote sensing of the atmosphere by resonance Raman LIDAR  

Energy Technology Data Exchange (ETDEWEB)

When in resonance, Raman scattering exhibits strong enhancement ranging from four to six orders of magnitude. This physical phenomenon has been applied to remote sensing of the Earth`s atmosphere. With a 16 inch Cassegrain telescope and spectrometer/ CCD-detector system, 70-150 ppm-m of SO{sub 2} in the atmosphere has been detected at a distance of 0.5 kilometer. This system can be used to detect/monitor chemical effluence in the atmosphere by their unique Raman fingerprints. Experimental result together with detailed resonance Raman and atmospheric laser propagation effects will be discussed.

1994-12-01

272

Refractometry of organosilica microspheres  

CERN Document Server

The refractive index of novel organosilica (nano/micro)material is determined using two methods. The first method is based on analysis of optical extinction efficiency of organosilica beads versus wavelength, which is obtained by a standard laboratory spectrometer. The second method relies on the measurable trapping potential of these beads in the focused light beam (laser tweezers). Polystyrene beads were used to test these methods, and the determined dispersion curves of refractive index values have been found accurate. The refractive index of organosilica beads has been determined to range from 1.60-1.51 over the wavelength range of 300-1100 nm.

2007-01-01

273

Radon grab sampling in water by means of radon transfer in activated charcoal collectors  

Energy Technology Data Exchange (ETDEWEB)

The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.

1999-08-01

274

Quasi-elastic electron scattering by GaAs surface  

International Nuclear Information System (INIS)

Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).

1994-03-20

275

Proton and deuteron spin structure function measurements in the resonance region  

Energy Technology Data Exchange (ETDEWEB)

The RSS collaboration has measured the spin structure functions of the proton and the deuteron at Jefferson Lab using the Hall C HMS spectrometer, a polarized electron beam and a polarized solid target. The asymmetries A and A were measured in the region of the nucleon resonances (0.82 GeV < W < 1.98 GeV) at an average four momentum transfer of Q2 = 1.3 GeV2. The extracted spin structure functions and their kinematic dependence will make a significant contribution in the study of higher-twist effects and polarized duality tests. A description of the experiment and the latest findings of the analysis will be presented.

2003-07-01

276

Observation of p pbar pi^0 and p pbar eta in psi' decays  

CERN Document Server

The processes psi'-->p pbar pi^0 and psi'-->p pbar eta are studied using a sample of 14 million psi' decays collected with the Beijing Spectrometer at the Beijing Electron-Positron Collider. The branching fraction of psi'-->p pbar pi^0 is measured with improved precision as (13.2\\pm 1.0\\pm 1.5)\\times 10^{-5}, and psi'-->p pbar eta is observed for the first time with a branching fraction of (5.8\\pm 1.1\\pm 0.7)\\times 10^{-5}, where the first errors are statistical and the second ones are systematic.

2005-01-01

277

Near-threshold production of {omega}-mesons in the pn{yields}d{omega} reaction  

Energy Technology Data Exchange (ETDEWEB)

The first measurement of the pn{yields}d{omega} total cross-section has been achieved at mean excess energies Q{approx}28 and 57 MeV by using a deuterium cluster-jet target. The momentum of the fast deuteron was measured in the ANKE spectrometer at COSY-Juelich and that of the slow ''spectator'' proton (p{sub sp}) from the pd{yields}p{sub sp}d{omega} reaction in a silicon telescope placed close to the target. The cross-sections lie above those measured for pp{yields}pp{omega} but seem to be below theoretical predictions. (orig.)

2004-09-01

278

Measurement of low-energy antiproton detection efficiency in BESS below 1 GeV  

Energy Technology Data Exchange (ETDEWEB)

An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.

2002-08-21

279

Measurement of cosmic-ray low-energy antiproton spectrum with the first BESS-Polar Antarctic flight  

CERN Document Server

The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1-4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiprotons to probe the effect of charge sign dependent drift in the solar modulation.

2008-01-01

280

Level structure of the doubly-odd /sup 242/Am nucleus  

Energy Technology Data Exchange (ETDEWEB)

The level structure of the doubly-odd /sup 242/Am nucleus was investigated by means of thermal-neutron-capture gamma-ray and conversion electron spectroscopy. Pair, curved-crystal, and ..beta.. spectrometers were used. The data from these measurements, combined with previous direct reaction results, permit us to establish a detailed level scheme including six new well-developed bands. Our experimental results are interpreted in the framework of the Nilsson model. Precise Gallagher-Moszkowski splittings and Newby odd-even shifts extracted from the data are compared with theoretical calculations.

1988-06-01

281

Laser photoelectron spectroscopy of ions. Progress report, August 1, 1982-July 31, 1983  

Energy Technology Data Exchange (ETDEWEB)

We have undertaken a program which measures the photoelectron spectra of negative-ion beams. This experiment has afforded us direct information about these ions and the corresponding neutral radicals. Several ions and numerous radicals are believed to be crucial intermediates in combustion processes and flame chemistry. We have fabricated a spectrometer which directly measures electron affinities (EA). Knowledge of the EA and gas-phase acidity of a radical has enabled us to deduce several radical heats of formation and bond strengths.

1983-03-01

282

Improved measurement of the branching ratio of J/psi-->K_S K_L  

CERN Document Server

The branching ratio of J/psi-->K_S K_L is measured with improved precision to be B(J/psi-->K_S K_L) = (1.82\\pm 0.04\\pm 0.13)\\times 10^{-4}. using J/psi data collected with the Beijing Spectrometer (BESII) at the Beijing Electron-Positron Collider. This result is used to test the perturbative QCD ``12%'' rule between psi(2S) and J/psi decays and to investigate the relative phase between the three-gluon and one-photon annihilation amplitudes in J/psi decays.

2004-01-01

283

Failure analysis on a ruptured petrochemical pipe  

Energy Technology Data Exchange (ETDEWEB)

The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)

2010-08-15

284

Experimental research on X-ray spectrum emitted from hot laser-produced aluminium plasma  

International Nuclear Information System (INIS)

The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)

2007-12-01

285

Effect of the size of an artificial neural network used as pattern identifier  

Energy Technology Data Exchange (ETDEWEB)

A novel way to extract relevant parameters associated with the outgoing ions from nuclear reactions, obtained by digitizing the signals provided by a Bragg curve spectrometer (BCS) is presented. This allowed the implementation of a more thorough pulse-shape analysis. Due to the complexity of this task, it was required to take advantage of new and more powerful computational paradigms. This was fulfilled using a back-propagation artificial neural network (ANN) as a pattern identifier. Over training of ANNs is a common problem during the training stage. In the performance of the ANN there is a compromise between its size and the size of the training set. Here, this effect will be illustrated in relation to the problem of Bragg Curve (BC) identification. (Author)

2003-07-01

286

COBE confounds the cosmologists  

Energy Technology Data Exchange (ETDEWEB)

The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.

1990-03-01

287

Basic Design Report of DC-TOF Inelastic Neutron Spectrometer  

Energy Technology Data Exchange (ETDEWEB)

We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.

2006-04-15

288

A preliminary design for a one GHz NMR spectrometer magnet  

International Nuclear Information System (INIS)

The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.

1993-09-20

289

Experimental Study of Hypernuclei Electroproduction by High Precision Spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the analysis of CH{sub 2}, ...

2009-12-01

290

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining gamma-ray intensities of individual fission ...

1997-05-01

291

Locally resonant acoustic metamaterials with 2D anisotropic effective mass density  

British Library Electronic Table of Contents (United Kingdom)

A two-dimensional (2D) lattice model with anisotropic resonant microstructures is found to provide an anisotropic band gap structure. A 2D continuum with anisotropic effective mass density is introduced to represent this lattice system. Two methods are proposed to derive the equivalent continuum. In the first method, the effective mass density of the equivalent continuum is obtained by matching the dispersion relations for harmonic waves propagating in the principal directions. The second approach employs an approximate estimation of the effective mass density by volume-averaging an effective mass that represents the resonant microstructure. For both equivalent continuum models, the effective mass density is frequency-dependent and may become negative in certain frequency ranges. Subsequen...

2011-01-01

292

Energetics of the fission process  

Energy Technology Data Exchange (ETDEWEB)

The mass asymmetry of fragments from nuclear fission of heavy nuclei is reviewed. While mass asymmetry is a common and well-known phenomenon for low-energy fission of the lighter actinides, more recent experiments have demonstrated that, for the heaviest actinides, the mass distribution switches to a symmetric one. On the other hand, it has been discovered that, though for fissioning nuclei with mass numbers A< or [approx]225 the mass distribution is basically symmetric, an asymmetric component is clearly to be identified for nuclei down to the Pb-region. In the absence of a generally accepted dynamical theory of fission, the above experimental findings are discussed in terms of static energy considerations. Triggered from the outset by the structure of the potential energy surface at the saddlepoint, the energy balance at the scission point between the available energy (Q-value) ...

1994-09-01

293

Energetics of the fission process  

International Nuclear Information System (INIS)

The mass asymmetry of fragments from nuclear fission of heavy nuclei is reviewed. While mass asymmetry is a common and well-known phenomenon for low-energy fission of the lighter actinides, more recent experiments have demonstrated that, for the heaviest actinides, the mass distribution switches to a symmetric one. On the other hand, it has been discovered that, though for fissioning nuclei with mass numbers A< or #approx#225 the mass distribution is basically symmetric, an asymmetric component is clearly to be identified for nuclei down to the Pb-region. In the absence of a generally accepted dynamical theory of fission, the above experimental findings are discussed in terms of static energy considerations. Triggered from the outset by the structure of the potential energy surface at the saddlepoint, the energy balance at the scission point between the available energy (Q-value) ...

294

Some properties of low-mass stellar models with chemically inhomogeneous neutral-stability zones  

Energy Technology Data Exchange (ETDEWEB)

Several low-mass models with an inhomogeneous radiative core and a convective envelope are investigated, the entire core or its upper portion being treated as a zone of neutral stability. Mixing by convective overshoot will then give rise to unstable structure.

1983-03-01

295

Scaling of offspring number and mass to plant and animal size: model and meta-analysis  

UK PubMed Central (United Kingdom)

The scaling of reproductive parameters to body size is important for understanding ecological and evolutionary patterns. Here, we derived allometric relationships for the number and mass of seeds, eggs...Full Text Available

2008-04-01

296

On the glueball spectrum in O(a)-improved lattice QCD  

CERN Document Server

We calculate the light `glueball' mass spectrum in N_f=2 lattice QCD using a fermion action that is non--perturbatively O(a) improved. We work at lattice spacings a~0.1 fm and with quark masses that range down to about half the strange quark mass. We find the statistical errors to be moderate and under control on relatively small ensembles. We compare our mass spectrum to that of quenched QCD at the same value of a. Whilst the tensor mass is the same (within errors), the scalar mass is significantly lighter in the dynamical lattice theory, by a factor of ~0.84 +/- 0.03. We discuss what the observed m_q dependence of this suppression tells us about the dynamics of glueballs in QCD. We also calculate the masses of flux tubes that wind around the spatial torus, and extract the string tension from these. As we decrease the quark ...

2002-01-01

297

Mass spectrometric characterization of high-temperature outgassing of anisotropic pyrolytic boron nitride  

International Nuclear Information System (INIS)

This paper describes a system for fast mass spectrometric characterization of high-temperature outgassing measurements and measuring the total quantity of gas evolved for boron nitride. 2 references, 1 figure, 2 tables.

298

Mass Treatment with Azithromycin for Trachoma Control: Participation Clusters in Households  

UK PubMed Central (United Kingdom)

BackgroundMass treatment to trachoma endemic communities is a critical part of the World Health Organization SAFE strategy. However, non-participation may not be at random, affecting...Full Text Available

299

Mass Balance and Present-day Antarctic Rebound and Gravity Change  

Science.gov (United States)

Mass Balance and Present-day Antarctic Rebound and Gravity Change. Erik R. Ivins , Eric Rignot, Xiaoping Wu, Carol A. Raymond (JPLKaltech, 300-233,4800 Oak ...

300

Mapping neuropeptide expression by mass spectrometry in single dissected identified neurons from the dorsal ganglion of the nematode Ascaris suum  

UK PubMed Central (United Kingdom)

We have developed a method for dissecting single neurons from the nematode Ascaris suum, in order to determine their peptide content by mass spectrometry (MS). In this paper,...Full Text Available

2010-07-21

301

High-precision determination of the light-quark masses from realistic lattice QCD  

CERN Document Server

Three-flavor lattice QCD simulations and two-loop perturbation theory are used to make the most precise determination to date of the strange-, up-, and down-quark masses, $m_s$, $m_u$, and $m_d$, respectively. Perturbative matching is required in order to connect the lattice-regularized bare- quark masses to the masses as defined in the \\msbar scheme, and this is done here for the first time at next-to-next-to leading (or two-loop) order. The bare-quark masses required as input come from simulations by the MILC collaboration of a highly-efficient formalism (using so-called ``staggered'' quarks), with three flavors of light quarks in the Dirac sea; these simulations were previously analyzed in a joint study by the HPQCD and MILC collaborations, using degenerate $u$ and $d$ quarks, with masses as low as $m_s/8$, and two values of the lattice spacing, with chiral ...

2006-01-01

302

Establishment of trophectoderm and inner cell mass lineages in the mouse embryo  

UK PubMed Central (United Kingdom)

The first cell lineage specification in mouse embryo development is the formation of trophectoderm (TE) and inner cell mass (ICM) of the blastocyst. This article is to review and discuss the...Full Text Available

2009-11-01

303

Determination of Salirasib (S-trans, trans-farnesylthiosalicylic acid) in human plasma using liquid chromatography-tandem mass spectrometry  

UK PubMed Central (United Kingdom)

A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of salirasib (S-trans, trans-farnesylthiosalicylic acid,...Full Text Available

2008-06-15

304

Design and Construction of a Versatile Dual Volume Heteronuclear Double Resonance Microcoil NMR Probe  

UK PubMed Central (United Kingdom)

Improved NMR detection of mass limited samples can be obtained by taking advantage of the mass sensitivity of microcoil NMR, while throughput issues can be addressed using multiple, parallel...Full Text Available

2009-04-01

305

Dendrochronological Mass Balance Reconstruction, Strathcona Provincial Park, Vancouver Island, British Columbia, Canada  

Science.gov (United States)

... 036[0598:DMBRSP]2.0.CO;2 Dendrochronological Mass Balance Reconstruction, Strathcona Provincial Park, Vancouver Island, British ...

306

DNA sequencing using biotinylated dideoxynucleotides and mass spectrometry  

UK PubMed Central (United Kingdom)

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MS) has been explored widely for DNA sequencing. The major requirement for this method is that the DNA sequencing fragments...Full Text Available

2001-11-01

307

Controlling Gas-Phase Reactions for Efficient Charge Reduction Electrospray Mass Spectrometry of Intact Proteins  

UK PubMed Central (United Kingdom)

Charge reduction electrospray mass spectrometry (CREMS) reduces the charge states of electrospray-generated ions, which concentrates the ions from a protein into fewer peaks spread over a larger...Full Text Available

2005-11-01

308

Cation Involvement in Telomestatin Binding to G-Quadruplex DNA  

UK PubMed Central (United Kingdom)

The binding mode of telomestatin to G-quadruplex DNA has been investigated using electrospray mass spectrometry, by detecting the intact complexes formed in ammonium acetate. The mass measurements show...Full Text Available

309

CT evaulation of thoracic and abdominal fatty masses  

International Nuclear Information System (INIS)

The diagnostic accuracy of computed tomography (CT) in several patterns of thoracic and abdominal fatty masses, has been examined. In selected cases our findings overlap the features of the recent literature. The possibility of surgical therapy in peculiar cases of adipose deposits, commonly esteemed benign, is considered.

1986-01-01

310

Assessment of 1183 screen-detected, category 3B, circumscribed masses by cytology and core biopsy with long-term follow up data  

UK PubMed Central (United Kingdom)

Discrete masses are commonly detected during mammographic screening and most such lesions are benign. For lesions without pathognomonically benign imaging features that are still regarded likely to...Full Text Available

2008-04-08

311

Applications of BMI or BSI: Differences and Revisions According to Age and Height  

UK PubMed Central (United Kingdom)

Validation of body-mass relationships requires a careful statistical analysis of data of normal weight individuals. BMI (ratio between body mass and square of body height) and BSI values (ratio between...Full Text Available

2010-01-01

312

Analytical validation of accelerator mass spectrometry for pharmaceutical development  

UK PubMed Central (United Kingdom)

The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of 14C/C ratio, independent of chemical separation procedures....Full Text Available

2010-03-01

313

Accretion disks  

Science.gov (United States)

Derivations are made for the mass and the mass-turnover time scale of an accretion disk as a function of the accretion rate, the observed disk radius, the non-viscous disk radius, and two parameters. These parameters depend on the effectiveness of viscosity and tidal angular momentum loss. Application is made to DQ Herculis.

1983-01-01

314

WWF - Global Warming Capable of Sparking Mass Species Extinctions  

Science.gov (United States)

... of species extinctions in around the world if global warming continues unabated, according to a new study published ... ...

315

Transition probabilities of rotational levels in "1"7"7Ta  

International Nuclear Information System (INIS)

... capture radioisotopes energy levels excited states intermediate mass nuclei

316

The distribution of mass-to-light ratio with radius in M31 and M33  

International Nuclear Information System (INIS)

1974. Netherlands Baldwin, JE Cambridge Univ. (UK). Cavendish Lab. Reidel.;

317

Tests of New Family Gauge Symmetry  

CERN Document Server

We explore the structure of a new family gauge symmetry U(3) and show its experimental signatures to search for. U(3) gauge bosons obviate an unwelcome deviation of the charged lepton mass formula with the running masses from that with the pole masses. The current structure of this model leads to flavor number violations via exchange of extra gauge bosons. We obtain bounds on the masses of the gauge bosons from rare kaon decay searches and muonium-antimuonium oscillation searches. We propose attractive signatures at LHC and lepton colliders and discuss feasibility of their discovery.

2010-01-01

318
320

Single and binary star evolution  

International Nuclear Information System (INIS)

After presenting a general account of the observed global properties of single stars of low, intermediate, and high mass, together with their theoretical Hertzsprung-Russell diagram evolution, attention is given to the observed properties of various evolved close binaries and to an assessment of the value of comparisons between observation and crude theory in characterizing the physics of mass transfer within interacting binary systems. Detailed consideration is then undertaken of such topics as stellar evolution in globular clusters, interior star changes due to nucleosynthesis and mixing, asymptotic giant branch stars of intermediate mass, the response of white dwarfs in binary systems to mass accretion, and scenarios for binary star evolution tending toward close white dwarf pairs.

321

Phantom dark energy with varying-mass dark matter particles: acceleration and cosmic coincidence problem  

CERN Document Server

We investigate several varying-mass dark-matter particle models in the framework of phantom cosmology. We examine whether there exist late-time cosmological solutions, corresponding to an accelerating universe and possessing dark energy and dark matter densities of the same order. Imposing exponential or power-law potentials and exponential or power-law mass dependence, we conclude that the coincidence problem cannot be solved or even alleviated. Thus, if dark energy is attributed to the phantom paradigm, varying-mass dark matter models cannot fulfill the basic requirement that led to their construction.

2009-01-01

322

Nuclear spectroscopy, ch. 8  

International Nuclear Information System (INIS)

Energy level schemes are derived from gamma spectroscopy of several medium-mass deformed nuclei by studying the decay or proton and #alpha# nuclear spectroscopic data. Some new isomeric studies are established among which is the 31 y "1"7"8Hf isomeric state for which Isup(#pi#), K was determined to be 16"+, 16. A four quasi-particle configuration was assigned to this state at 2447.5 +- 2.5 KeV. Atomic masses have been calculated from various measurements and, on the basis of mass formulae extrapolated to neighboring mass regions.

323

Noncircular gas velocities and the radial dependence of mass-to-light ratio in NGC 4594 (the Sombrero Galaxy)  

International Nuclear Information System (INIS)

The mass distribution of the Sombrero Galaxy, NGC 4594, is calculated in order to investigate the suspicion that the rotational velocity of the galactic gas does not measure the circular velocity in the galaxy. It is shown that the H II rotation velocities are much less than circular in the central 35 arcsec of the galaxy, and that the suspicion is correct. Thus, the H II rotation velocities cannot be used to measure the mass distribution. The absorption-line rotation curve is used to derive the mass distribution, and it is found that the M/L ratio is nearly constant. It is concluded that the visible matter is self-gravitating at least in the central 180 arcsec. 44 references.

325

Measuring relative probability of Am-242 #beta#-decay  

International Nuclear Information System (INIS)

... americium 241 americium 242 beta decay chain reactions integral doses mass

326

Measurements and evaluations of nuclear data on actinide isotopes  

International Nuclear Information System (INIS)

The measurements of the nuclear decay of actinide isotopes and the evaluation of the radioactive properties of nuclide with the mass 242 is discussed in this paper.

1979-08-01

327

Mass: Evolving Tool of the US Operational Artist  

Science.gov (United States)

... ire examples of successive operations, as are the breakout operations GOODWOOD and COBRA. Also, for the first time, ...

1993-05-14

328

MINEQL-PC. Chemical Equilibrium Composition of Aqueous Systems  

Energy Technology Data Exchange (ETDEWEB)

MINEQL is a subroutine package to calculate equilibrium composition of an aqueous system, accounting for mass transfer.

1986-11-21

330

Decay of "1"7"7Ta to levels of "1"7"7Hf  

International Nuclear Information System (INIS)

... intermediate mass nuclei isotopes leptonic decay nuclei odd-even nuclei

1973-10-01

331

Collective model for the odd-mass transitional nucleus "1"8"7Ir  

International Nuclear Information System (INIS)

... collective model hamiltonians iridium 187 matrix elements nuclear cores

1976-06-15

332

Chiral and Continuum Extrapolation of Partially-Quenched Hadron Masses  

CERN Document Server

Using the finite-range regularisation (FRR) of chiral effective field theory, the chiral extrapolation formula for the vector meson mass is derived for the case of partially-quenched QCD. We re-analyse the dynamical fermion QCD data for the vector meson mass from the CP-PACS collaboration. A global fit, including finite lattice spacing effects, of all 16 of their ensembles is performed. We study the FRR method together with a naive polynomial approach and find excellent agreement ~1% with the experimental value of M_rho from the former approach. These results are extended to the case of the nucleon mass.

2005-01-01

334

A HREELS Investigation of Ethylene on Pt Model Catalysts  

Science.gov (United States)

... analyzer section for angle resolved measurements, and a thin film evaporator with a quartz crystal microbalance to measure the mass deposition. ...

1990-05-20

335

Environmental monitoring as an important tool for safeguards of nuclear material and nuclear forensics  

International Nuclear Information System (INIS)

The use of environmental monitoring as a technique to identify activities related to the nuclear fuel cycle has been proposed by international safeguards organizations. The elements specific for each kind of nuclear activity, or 'nuclear signatures', inserted in the ecosystem can be intercepted by different live organisms. This work demonstrates the technical viability of using pine needles as bioindicators of nuclear signatures associated with uranium enrichment activities. Additionally, it proposes the use of HR-ICP-MS to identify the signature corresponding to that kind of activities in the ecosystem. Nitric acid solutions, used to wash pine needles sampled near nuclear facilities and containing only 0.1 #mu#g x kg"-"1 of uranium, exhibit a n("2"3"5U)/n("2"3"8U) isotopic abundance ratio of 0.0092#+-#0.0002, while solutions originated from samples collected at places located more than 200 km far from activities related to the nuclear fuel cycle exhibit a value of ...

2006-11-01

336

Determination of a various ions such as alkali metals in leaves, stems, roots and seeds of the radish and their distribution  

Energy Technology Data Exchange (ETDEWEB)

Determination, uptake and distribution of various ions such as alkali metals in three different parts (leaf, stem and root) and seeds of radish (Kaiware daikon) were examined using flame emission spectrometry and ICP-AES. In order to examine the influence of concentration alkali metal ion concentration in the radish culture solution on the uptake and distribution of these metals, the radish was grown at pH 5.6 in solutions containing alkali metal chloride at concentrations ranging from 10{sup -5} to 10{sup -1} mol dm{sup -3}. When the radish were grown in culture solution with alkali metal ions of low concentrations (10{sup -5} and 10{sup -4} mol dm{sup -3}), Na, K, Rb and trace Li were detected in leaves, stems and roots while Cs was scarcely detected. However, the contents of Na, K, Li in these organs were the same as those in radish cultivated in pure water. An increase of Rb uptake was observed with an increased Rb concentration. In the case of high ...

1995-05-01

337

A newly synthesized glycine derivative to control uniform and pitting corrosion processes of Al induced by SCN"- anions - Chemical, electrochemical and morphological studies  

International Nuclear Information System (INIS)

A newly synthesized glycine derivative (termed GlyD), 2-(4-(dimethylamino)benzylamino)acetic acid hydrochloride, was used to inhibit uniform and pitting corrosion processes of Al in 0.50 M KSCN solutions (pH 6.8) at 25 "oC. For uniform corrosion inhibition study, Tafel extrapolation, linear polarization resistance and impedance methods were used, complemented with SEM examinations. An independent method of chemical analysis, namely ICP-AES (inductively coupled plasma atomic emission spectrometry) was also used to test validity of corrosion rate measured by Tafel extrapolation method. GlyD inhibited uniform corrosion, even at low concentrations, reaching a value of inhibition efficiency up to 97% at a concentration of 5 x 10"-"3 M. Results obtained from the different corrosion evaluation techniques were in good agreement. This new synthesized glycine derivative was also used to control pit nucleation and growth on the pitted Al surface based on cyclic polarization, ...

2010-10-01

338

Quantitative spectroscopy of close binary stars  

CERN Document Server

The method of spectral disentangling has now created the opportunity for studying the chemical composition in previously inaccessible components of binary and multiple stars. This in turn makes it possible to trace their chemical evolution, a vital aspect in understanding the evolution of stellar systems. We review different ways to reconstruct individual spectra from eclipsing and non-eclipsing systems, and then concentrate on some recent applications to detached binaries with high-mass and intermediate-mass stars, and Algol-type mass-transfer systems.

2011-01-01

339

Neutron-proton mass difference in isospin-asymmetric nuclear matter  

Energy Technology Data Exchange (ETDEWEB)

Isospin-breaking effects in the baryonic sector are studied in the framework of a medium-modified Skyrme model. The neutron-proton mass difference in infinite, asymmetric nuclear matter is discussed. In order to describe the influence of the nuclear environment on the skyrmions, we include energy-dependent charged and neutral pion optical potentials in the s- and p-wave channels. The present approach predicts that the neutron-proton mass difference is mainly dictated by its strong part and that it strongly decreases in neutron matter. (orig.)

2007-06-15

340

Isotopic effects on solubility-limited mass transfer  

Energy Technology Data Exchange (ETDEWEB)

In our previous theoretical analyses, solubility-limited mass transfer from waste solids applies if a species is at a constant elemental concentration in liquid at the waste surface. For an element with isotopes that decay appreciably during the time of interest, a solubility boundary condition results in a time-dependent boundary concentration of each isotope. Here we present mass-transfer equations that include the effects of isotopic decay boundary conditions. 9 refs., 1 fig.

1989-06-01

341

Influence of rotation and magnetic field on the minimum mass of a main-sequence star  

Energy Technology Data Exchange (ETDEWEB)

The influence of rigid-body and differential rotation and of a fine-scale chaotic magnetic field and a poloidal magnetic field on the minimum mass of a main-sequence star is investigated. It is shown that rotation and a magnetic field with an energy equal to 10--20% of the star's gravitational energy increase the minimum mass of a main-sequence star by 1.5--2 times.

1980-11-01

342

Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium  

Science.gov (United States)

Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively.

1988-02-01

343

Flavor Mixing of Quarks and Neutrinos  

CERN Document Server

The "texture zero mass matrices" for the quarks and leptons describe very well the flavor mixing of the quarks and leptons. We can calculate the angles of the unitarity triangle. We expect the angle alpha of the unitarity triangle to be 90 degrees. The masses of the neutrinos can be calculated - they are very small, the largest neutrino mass is 0.05 eV. We calculated the matrix element of the mixing matrix, relevant for the reactor mixing angle. It can be measured in the near future in the DAYA BAY experiment.

2011-01-01

344

Effluent reduction using pinch technology: Targets for reduction and capital costs for mass exchange networks  

Energy Technology Data Exchange (ETDEWEB)

This paper illustrates how the techniques developed by the authors for capital cost targeting of mass exchange networks can be applied to determination of capital investment targets for reduction in effluent for existing systems involving mass exchange. The results is an impact diagram which shows the relationship between effluent reduction and capital investment, indicating a region of limiting return on investment as well as the maximum possible reduction in effluent. (au)

1999-02-01

345

ppbar enhancement in B and J/Psi decay  

CERN Document Server

The near-threshold enhancement in the ppbar invariant mass spectrum from the B^+ -> K^+ ppbar decay reported recently by the BaBar Collaboration is studied within the J\\"ulich NNbar model. We illustrate that the invariant mass dependence of the ppbar spectrum close to the threshold can be reproduced by the final state interactions. This explanation is in line with our previous analysis of the ppbar invariant mass spectrum from the J/Psi -> gamma ppbar decay measured by the BES Collaboration. We also comment on a structure found recently in the pi^+ pi^- eta' mass spectrum of the radiative J/Psi decay by the BES Collaboration. In particular we argue that one should be rather cautions in bringing this structure in connection with the enhancement found in the ppbar invariant mass spectrum or with the existence of NNbar bound states.

2006-01-01

346

The Dissipative Merger Progenitors of Elliptical Galaxies  

CERN Document Server

We address the deviations of the scaling relations of elliptical galaxies from the expectations based on the virial theorem and homology, including the "tilt" of the "fundamental plane" and the steep decline of density with mass. We show that such tilts result from dissipative major mergers once the gas fraction available for dissipation declines with progenitor mass, and derive the scaling properties of the progenitors. We use hydrodynamical simulations to quantify the effects of major mergers with different gas fractions on the structural properties of galaxies. The tilts are driven by the differential shrinkage of the effective stellar radius as a function of dissipation in the merger, while the correlated smaller enhancements in internal velocity and stellar mass keep the slope of the velocity-stellar mass relation near V \\pr M_*^{1/4}. The progenitors match a straightforward model of disc ...

2006-01-01

347

Security features of a nuclear material accounting system  

Energy Technology Data Exchange (ETDEWEB)

The Los Alamos Nuclear Material Accounting and Safeguards System (MASS) is a near-real-time accountability system for bulk materials, discrete items, and material undergoing dynamic processing. MASS has evolved from an eighty-column card based process control system to a very sophisticated computer system. The security of the MASS computer system is provide through various access controls. There are two kinds of access control to be addressed. They are physical access control to the hardware which make up the system, and access control to the software. There are many features which provide a measure of security to the hardware that will be discussed. Access to the software is controlled by a security password. Access to various transaction activities in the system is controlled through the level of MASS user privilege. Details of MASS user privilege will be discussed.

1988-01-01

348

Search for Z' ---> e+ e- using dielectron mass and angular distribution  

Energy Technology Data Exchange (ETDEWEB)

The authors search Z{prime} bosons in dielectron events produced in p{bar p} collisions at {radical}s = 1.96 TeV, using a 0.45 fb{sup -1} dataset accumulated with the CDF II detector at the Fermilab Tevatron. To identify the Z{prime} {yields} e{sup +}e{sup -} signal, both the dielectron invariant mass distribution and the angular distribution of the electron pair are used. No evidence of a signal is found, and 95% confidence level lower limits are set on the Z{prime} mass for several models. Limits are also placed on the mass and gauge coupling of a generic Z{prime}, as well as on the contact interaction mass scales for different helicity structure scenarios.

2006-02-01

349

Robust curve fitting method for single binding site mass action model of radioimmunoassay  

International Nuclear Information System (INIS)

The difficulty and unstability of the parameter estimation of mass action model for radioimmunoassay are the major obstacles to its application in routine work. A unique robust curve fitting method for the mass action model was introduced. large numbers of simulated data were generated with Monte Carlo method to compare the accuracy and robustness of the robust fitting and the least squre fitting (Marquardt method) of the mass action model. The results demonstrated that the new robusst method significantly increased the accuracy and reliability of data processing with the mass action model. It also markedly reduced the influence of outliers in the fitting of RIA data, and it was always 'convergent'. This robust method could also be applied to other mathematical models which can be transformed into high degree equations and no initial estimates are needed for curve fitting.

350

On the elliptical flow and mass asymmetry of the colliding nuclei  

British Library Electronic Table of Contents (United Kingdom)

A study of elliptical flow is carried out for different mass asymmetries of colliding nuclei using the reactions of Formula Not Shown ( Formula Not Shown ), Formula Not Shown ( Formula Not Shown ) and Formula Not Shown ( Formula Not Shown ). The present reactions are simulated at incident energies between 50 and 250 MeV/nucleon within the framework of isospin-dependent quantum molecular dynamics model. For the present analysis, total mass of colliding pairs is kept fixed and mass asymmetry is varied between 0.3 and 0.7. The elliptical flow shows a transition from in-plane to out-of-plane in the mid rapidity region with incident energy. The transition energy is found to increase with the mass asymmetry for light charged particles. A good agreement is obtained with experimental measurements.

2011-01-01

351

Mass-loss in 2D zero-age main-sequence stellar models  

British Library Electronic Table of Contents (United Kingdom)

Abstract A large number of massive stars are known to rotate rapidly, resulting in a significant distortion and variation in surface temperature from the pole to the equator. Radiatively driven mass-loss is temperature-dependent, so rapid rotation produces a variation in the mass-loss and angular momentum loss rates across the surface of the star, which is expected to affect the evolution of rapidly rotating massive stars. In this work, we use zero-age main-sequence (ZAMS) stellar models to investigate the two-dimensional effects of rotation on stellar mass-loss, using two common prescriptions for radiatively driven mass-loss. The associated loss of angular momentum from these models is also considered. Using 2D stellar models, which give the variation in surface parameters as a function o...

2011-01-01

352

Mass transfer in horizontal flow channels with thermal gradients  

Energy Technology Data Exchange (ETDEWEB)

Mass transfer to a wall of a horizontal rectangular channel reactor was investigated by the limiting current technique for Reynolds numbers ranging from 200 to 32000. Overall mass transfer coefficients at various mass transfer surface angles were obtained while the reactor was operated under isothermal and non-isothermal conditions. Dimensionless correlations were developed for isothermal flows from 25 to 55{sup o}C and for non-isothermal flows with applied temperature differences up to 30{sup o}C. In the laminar flow range natural convection dominated, but under turbulent conditions combined natural and forced convection prevailed. Mass transfer was approximately doubled under optimum selection of channel surface rotation, temperature gradient and flow rate. (author)

1997-12-15

353

Mass transfer in horizontal flow channels with thermal gradients  

International Nuclear Information System (INIS)

Mass transfer to a wall of a horizontal rectangular channel reactor was investigated by the limiting current technique for Reynolds numbers ranging from 200 to 32000. Overall mass transfer coefficients at various mass transfer surface angles were obtained while the reactor was operated under isothermal and non-isothermal conditions. Dimensionless correlations were developed for isothermal flows from 25 to 55"oC and for non-isothermal flows with applied temperature differences up to 30"oC. In the laminar flow range natural convection dominated, but under turbulent conditions combined natural and forced convection prevailed. Mass transfer was approximately doubled under optimum selection of channel surface rotation, temperature gradient and flow rate. (author)

1997-12-01

354

Mass density of glassy Pd{sub 80}Si{sub 20}during low temperature light ion irradiation.  

Energy Technology Data Exchange (ETDEWEB)

Changes in mass density of amorphous Pd{sub 80}Si{sub 20} were monitored in situ during irradiation with He{sup 2+} and H{sup +} ions at temperatures below 100 K and during subsequent thermal treatment. The mass density decreased with increasing ion fluence and exponentially approached a saturation value of -1.2%, corresponding to a recombination volume of 190 atomic volumes. The initial swelling rate was 2.3 atomic volumes/displaced atom. The mass density of the irradiated material increased during subsequent thermal treatment, and the irradiation-induced decrease of the mass density recovered completely at room temperature.

2001-10-01

355

Heat and mass transfer analogy studies of binary liquid mixture in comparison with ethanol-n-heptane evaporating to air  

Energy Technology Data Exchange (ETDEWEB)

An experimental and theoretical study of heat and mass transfer analogy and a comparison of that to a binary liquid mixture evaporation is presented. Common organic solvents, ethanol and n-heptane, were used to form an alcohol - hydrocarbon mixture. Studies were carried out in a horizontal rectangular channel having air flow velocities of 0.2 - 0.9 m/s. Heat transfer coefficients were measured with a copper plate resistor and mass transfer coefficients with a square pool. The heat and mass transfer analogy is presented for a system having two evaporating compounds with a fixed value of air flow and verified by measuring and comparing mass transfer coefficients for distilled water with air flow velocities of 0.2 - 0.9 m/s. An illustrative example of the use of the theory for industrial ventilation is presented. (author)

1995-12-31

356

Glueball Mass Spectrum in KK Monopole Background  

CERN Document Server

We consider typeIIA supergravity solution of D2-branes and D3-branes localized within D6-branes in the near-core region of D6-branes. With these solutions we can calculate the spectrum of the glueball mass in QCD3 and QCD4. The equation of motion describing the dilaton has the same eigenvalues and the same glueball masses in QCD3 and QCD4. Glueball mass spectrum is the same in the near core region of D6-branes of their M-theory counterpart is KK monopole. We conclude that the glueball mass spectrum is the same in QCD3 and QCD4 by considering the `near-core' limit of D6-branes of which M-theory counterpart (KK monopole background) becomes an ALE space with an $A_{N-1}$ singularity times 7 dimensional Minkowski space $M^{(6,1)}$.

1999-01-01

357

Evidence for a central dark mass in NGC 4594 (the Sombrero galaxy)  

International Nuclear Information System (INIS)

This paper discusses the results of the absorption-line spectroscopy carried out with the Canada-France-Hawaii Telescope on the prototypical Sa galaxy NGC 4594 (the Sombrero galaxy). Two conclusions were derived concerning this galaxy. First, at the values of r less than 10 arcsec, there is a well-defined nuclear disk of stars which is not obviously connected to the main disk at larger radii. Second, the mass-to-light ratio, M/L(V), of the galaxy rises abruptly at r values less than 1 arcsec to values of M/L(V) greater than 50, which is at least 10 times as large as the mass-to-light ratios at r values above 2 arcsec. This implies the presence of a central dark mass of a magnitude between 10 to the 8.5th and 10 to the 9.5th solar masses. 54 references.

358

Enthalpy and mass flowrate measurements for two-phase geothermal production by Tracer dilution techniques  

Energy Technology Data Exchange (ETDEWEB)

A new technique has been developed for the measurement of steam mass flowrate, water mass flowrate and total enthalpy of two-phase fluids produced from geothermal wells. The method involves precisely metered injection of liquid and vapor phase tracers into the two-phase production pipeline and concurrent sampling of each phase downstream of the injection point. Subsequent chemical analysis of the steam and water samples for tracer content enables the calculation of mass flowrate for each phase given the known mass injection rates of tracer. This technique has now been used extensively at the Coso geothermal project, owned and operated by California Energy Company. Initial validation of the method was performed at the Roosevelt Hot Springs geothermal project on wells producing to individual production separators equipped with orificeplate flowmeters for each phase.

1993-01-28

359

Empirically Consistent Electroweak Radiative Corrections with the Two-Higgs Doublet Model  

CERN Document Server

The electroweak radiative correction, which turned out to be marginal within the standard electroweak model having the minimal Higgs sector in view of the present experimental information, fits well the experiment when the Higgs sector is extended to have two Higgs doublets. We predict the range where the charged and CP odd Higgs boson masses would lie, taking the two CP even neutral Higgs boson masses to be degenerate which makes the analysis in multiparameter space feasible. It is shown that the mass of neutral Higgs doublet boson can arbitrarily be large consistently with the $W$ mass, if the charged Higgs boson is present and it's mass lies in some appropriate ranges.

2008-01-01

360

Dynamics of the globular cluster M2 (NGC 7089)  

International Nuclear Information System (INIS)

We have obtained radial velocities for 69 stars in the globular cluster M2 (NGC 7089). M2's rotation axis is, within sizeable uncertainties, perpendicular to the major axis determined by the flattening. The ratio of rotational to random kinetic energy agrees with that predicted from the ellipticity assuming an oblate figure and an isotropic velocity-dispersion tensor. We have fitted King-Michie models to determine M2's mass, the exponent of an assumed power-law mass function, and the anisotropy radius. The most significant sources of uncertainty in the modeling are the velocity dispersion, the distance, and the mass-luminosity relation for the cluster stars. The models favor mass functions similar to or shallower than the Salpeter initial-mass function and a moderate amount of velocity anisotropy.

361

Are Stars with Planets Polluted?  

CERN Document Server

We compare the metallicities of stars with radial velocity planets to the metallicity of a sample of field dwarfs. We confirm recent work indicating that the stars-with-planet sample as a whole is iron rich. However, the lowest mass stars tend to be iron poor, with several having [Fe/H]0.48) that contributes to but does not explain the mass-metallicity trend in the stars-with-planets sample. We use Monte Carlo models to show that adding an average of 6.5 Earth masses of iron to each star can explain both the mass-metallicity and the age-metallicity relations of the stars-with-planets sample. However, for at least one star, HD 38529, there is good evidence that the bulk metallicity is high. We conclude that the observed metallicities and metallicity trends are the result of the interaction of three effects; accretion of about 6 Earth masses of iron rich material, selection effects, ...

2002-01-01

362

Nuclear mass prediction as an image reconstruction problem: can observed pattern determine mass values?  

Energy Technology Data Exchange (ETDEWEB)

Theoretical prediction of nuclear masses is analyzed as a pattern recognition problem on the N-Z plane. A global pattern is observed by plotting the differences between measured masses and Liquid Drop Model (LDM) predictions. After unfolding the data by removing the smooth LDM mass contributions, the remaining microscopic effects have proved difficult to model, although they display a striking pattern. These deviations carry information related to shell closures, nuc]ear deformation and the residual nuclear interactions. In the present work the more than 2000 known nuclear masses are studied as an array in the N-Z plane viewed through a mask, behind which the approximately 7000 unknown unstable nuclei that can exist between the proton and neutron drip lines are hidden. We show here that employing a Fourier transform deconvolution method these by masses can be predicted with similar ...

2006-07-01

363

Nuclear mass prediction as an image reconstruction problem: can observed pattern determine mass values?  

International Nuclear Information System (INIS)

Theoretical prediction of nuclear masses is analyzed as a pattern recognition problem on the N-Z plane. A global pattern is observed by plotting the differences between measured masses and Liquid Drop Model (LDM) predictions. After unfolding the data by removing the smooth LDM mass contributions, the remaining microscopic effects have proved difficult to model, although they display a striking pattern. These deviations carry information related to shell closures, nuc]ear deformation and the residual nuclear interactions. In the present work the more than 2000 known nuclear masses are studied as an array in the N-Z plane viewed through a mask, behind which the approximately 7000 unknown unstable nuclei that can exist between the proton and neutron drip lines are hidden. We show here that employing a Fourier transform deconvolution method these by masses can be predicted with similar ...

364

Light meson mass dependence of the positive-parity heavy-strange mesons  

Energy Technology Data Exchange (ETDEWEB)

We calculate the masses of the resonances D{sub s0}{sup *}(2317) and D{sub s1}(2460) as well as their bottom partners as bound states of a kaon and a D{sup (*)} - and B{sup (*)} -meson, respectively, in unitarized chiral perturbation theory at next-to-leading order. After fixing the parameters in the D{sub s0}{sup *}(2317) channel, the calculated mass for the D{sub s1}(2460) is found in excellent agreement with experiment. The masses for the analogous states with a bottom quark are predicted to be M{sub B{sup *}{sub s0}}=(5696{+-}40) MeV and M{sub B{sub s1}}=(5742{+-}40) MeV in reasonable agreement with previous analyses. In particular, we predict M{sub B{sub s1}}-M{sub B{sub s0}}{sup *}=46{+-}1 MeV. We also explore the dependence of the states on the pion and kaon masses. We argue that the kaon mass dependence of a kaonic bound state should be almost linear with slope about unity. ...

2011-02-15

365

ZnO microsheet modified TiO2 nanoparticle composite films for dye-sensitized solar cells  

British Library Electronic Table of Contents (United Kingdom)

Randomly oriented ZnO microsheets were successfully self-assembled on TiO2 nanoparticle (TN) film to act as the scattering layer via a cathodic electrodeposition process. The light scattering properties of ZnO microsheets were studied by UV-Vis spectrometer in the 400?800 nm wavelength range. It was found that ZnO microsheets exhibited excellent ability to scatter the incident light for ZnO microsheet-TiO2 nanoparticle (ZT) composite films. The results showed that dye-sensitized solar cells (DSSCs) fabricated with ZT composite films showed higher short-circuit density (J sc) and conversion efficiency than TN-based DSSCs, due to the light scattering properties of ZnO microsheets.

2010-01-01

366

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

367

Ternary and quaternary fission  

Energy Technology Data Exchange (ETDEWEB)

In a systematic survey of ternary fission induced by thermal neutrons at the Lohengrin spectrometer of the ILL/Grenoble, the target nucleus {sup 249}Cf has recently been added to the list of actinides under study. Special emphasis was put on the search for the heaviest ternary particles. At the limit of detection (some 10{sup -9} per fission), the heaviest isotopes observed for {sup 249}Cf(n{sub th},f) are {sup 37}Si and {sup 37}S. Another rare process in low energy fission is quaternary fission. Here two light charged particles accompany the main fragments. The reaction {sup 233} U(n,f) has been studied at a cold neutron beam of the ILL. Two processess have to be disentangled: simultaneous and sequential quaternary fission. In the simultaneous decay the most probable combination of particles is ({alpha} + {alpha}) with a yield of {approx}10{sup -7}/fission.

2004-04-05

368

Study of the reaction {sup 22}Ne(131 MeV) + {sup 208}Pb with a PIAVE-ALPI test beam and the PRISMA-CLARA set-up  

Energy Technology Data Exchange (ETDEWEB)

An opportunity to study the system {sup 22}Ne+{sup 208}Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The {sup 22}Ne projectiles, having the kinetic energy of 131 MeV, collided with a {sup 208}Pb target 300 {mu}g/cm{sup 2} thick. (The beam was run for {approx}20 hours with a current of {approx}6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, {approx}70 degrees), coupled to the CLARA array of germanium detectors.

2005-07-01

369

Study of duality in the transition region at Jlab  

Energy Technology Data Exchange (ETDEWEB)

Inclusive double spin asymmetries obtained by scattering polarized electrons off polarized protons and deuterons have been analyzed to address the issue of quark-hadron duality in the polarized spin structure functions g^p_1 and g^d_1. A polarized electron beam, solid polarized NH_3 and ND_3 targets and the CEBAF Large Acceptance Spectrometer (CLAS) in Hall B were used to collect the data. The resulting g^p_1 and g^d_1 were averaged over the nucleon resonance energy region (M < W < 2.00 GeV), and three lowest lying resonances individually for tests of global and local duality.

2007-01-01

370

Spectroscopy of neutron-rich {sup 59-63}Mn isotopes  

Science.gov (United States)

The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a {sup 238}U target with a beam of {sup 70}Zn at an energy of E{sub lab}=460 MeV. Prompt {gamma} rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.

2008-08-15

371

Spectroscopy of neutron-rich "5"9"-"6"3Mn isotopes  

International Nuclear Information System (INIS)

The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a "2"3"8U target with a beam of "7"0Zn at an energy of E_l_a_b=460 MeV. Prompt #gamma# rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.

2008-08-01

372

Spectroscopic measurement of the Doppler broadening region of He II line emission of DT plasmas using impurity pellets  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of spectroscopic measurement of the velocity distribution of alpha particle using the ablation cloud of a lithium or boron pellet was tested in the DT experiment of TFTR. The measurement was performed using a 10-channel narrow-band filtered spectrometer in the wavelength covering the 3.5 MeV alpha particle Doppler broadening region of the He II 468.6 nm line and its vicinity. The spectra from a lithium pellet consists of the continuum bremsstrahlung background, lithium line emissions and possibly a 468.6 nm helium line. However, no clear evidence of alpha particles was observed, even when boron pellets were injected. (orig.) 4 refs.

1997-03-01

373

Silicate emission in Orion  

CERN Document Server

We present mid-infrared spectro-imagery and high-resolution spectroscopy ofthe Orion bar and of a region in the Orion nebula. These observations have beenobtained in the Guaranteed Time with the Circular Variable Filters of the ISOcamera (CAM-CVF) and with the Short Wavelength Spectrometer (SWS), on board theEuropean Infrared Space Observatory (ISO). Our data shows emission fromamorphous silicate grains from the entire HII region and around the isolatedO9.5V star Theta2 Ori A. The observed spectra can be reproduced by a mixture ofinterstellar silicate and carbon grains heated by the radiation of the hotstars present in the region. Crystalline silicates are also observed in theOrion nebula and suspected around Theta2 Ori A. They are probably ofinterstellar origin. The ionization structure and the distribution of thecarriers of the Aromatic Infrared Bands (AIBs) are briefly discussed on thebasis of the ISO observations.

2000-01-01

374

Resonant inelastic soft x-ray scattering of CdS: a two-dimensional electronic structure map approach  

Energy Technology Data Exchange (ETDEWEB)

Resonant inelastic x-ray scattering (RIXS) with soft x-rays is uniquely suited to study the elec-tronic structure of a variety of materials, but is currently limited by low (fluorescence yield) count rates. This limitation is overcome with a new high-transmission spectrometer that allows to measure soft x-ray RIXS"maps." The S L2,3 RIXS map of CdS is discussed and compared with density functional calculations. The map allows the extraction of decay channel-specific"absorp-tion spectra," giving detailed insight into the wave functions of occupied and unoccupied elec-tronic states.

2008-09-24

375

Radial velocities, dynamics of stars and nebulosities with GAIA and VLT-GIRAFFE  

CERN Document Server

This document is divided in two parts. The first part deals with the radial velocities (RV) distributions for B-type stars and nebulosities observed with the VLT-GIRAFFE in the Large and Small Magellanic Clouds towards the open clusters NGC2004 and NGC330. Thanks to the resolution of GIRAFFE spectra, we found that the RV distribution for the nebulosities in the LMC is bi-modal. This bi-modality can be interpreted, in term of dynamics, by the expansion of the LMC4 superbubble. The second part deals with the GAIA space mission and the determination of the radial velocities by using Radial Velocity Spectrometer (RVS) spectra. The methods to determine the radial velocities are presented as well as preliminary results on simulated RVS spectra.

2008-01-01

376

Precise Determination of the Neutron Magnetic Form Factor to Higher Q{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

The neutron elastic magnetic form factor G{sub M}{sup n} has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV{sup 2} to nearly 5 GeV{sup 2} in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

377

Precise Determination of the Neutron Magnetic Form Factor to Higher Q"2  

International Nuclear Information System (INIS)

The neutron elastic magnetic form factor G_M"n has been extracted from quasielastic scattering from deuterium in the CEBAF Large Acceptance Spectrometer, CLAS [B. Mecking et al., Nucl. Inst. and Meth. A 503 (2003) 513]. The kinematic coverage of the measurement is continuous over a broad range, extending from below 1 GeV"2 to nearly 5 GeV"2 in four-momentum transfer squared. High precision is achieved by employing a ratio technique in which most uncertainties cancel, and by a simultaneous in-situ calibration of the neutron detection efficiency, the largest correction to the data. Preliminary results are shown with statistical errors only.

2005-06-13

378

Polarized neutron diffraction study of CePd{sub 3}  

Energy Technology Data Exchange (ETDEWEB)

We have performed polarized neutron diffraction measurements on the intermediate valence compound CePd{sub 3} using the D3 spectrometer at the ILL. The results show that at low temperatures, 1.7 K, as well as at 100 K, the field-induced magnetic amplitudes measured in a field of 4.6 T could be interpreted in terms of two contributions: a 4f-type contribution with a Ce{sup 3+} form factor, and an extra delocalized contribution (relatively narrow in q-extent). In particular, we find that the values of the 4f moment deduced from the extrapolation of the neutron data to Q=0 are systematically lower than the values deduced from bulk magnetization measurements performed on the same sample. This difference can be ascribed to a possible positive polarization of the conduction band which is similar at both temperatures.

2004-07-15

379

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u {sup 86}Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss mesurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parameterization. The resulting prospects for reaching even more neutron-rich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1991-10-01

380

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u sup 86 Kr beam  

Energy Technology Data Exchange (ETDEWEB)

We have measured production cross-sections of the new neutron-rich isotopes {sup 58}Ti, {sup 61}V, {sup 63}Cr, {sup 66}Mn, {sup 69}Fe, {sup 71}Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u {sup 86}Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide {sup 78}Ni, are discussed. (orig.).

1992-07-01

381

New neutron-rich isotopes in the scandium-to-nickel region, produced by fragmentation of a 500 MeV/u "8"6Kr beam  

International Nuclear Information System (INIS)

We have measured production cross-sections of the new neutron-rich isotopes "5"8Ti, "6"1V, "6"3Cr, "6"6Mn, "6"9Fe, "7"1Co and neighbouring isotopes that have been identified as projectile fragments from reactions between a 500 MeV/u "8"6Kr beam and a beryllium target. The isotope identification was performed with the zero-degree magnetic spectrometer FRS at GSI, using in addition time-of-flight and energy-loss measurements. The experimental production cross-sections for the new nuclides and neighbouring isotopes are compared with an empirical parametrization. The resulting prospects for reaching even more neutronrich isotopes, such as the doubly-magic nuclide "7"8Ni, are discussed. (orig.).

382

Neutron inelastic scattering to octupole states in single-closed-shell nuclei  

International Nuclear Information System (INIS)

Differential cross sections for the excitation of the first octupole-vibrational state in the closed-neutron-shell nuclides "8"8Sr and "9"0Zr and in the closed-proton shell-nuclei sup(116,118,120,124)Sn by 11 MeV neutrons are presented. The distorted-wave Born approximation is used to obtain deformation lengths, delta(3"-) for each state. Results are compared with earlier measurements of inelastic proton scattering to the same states. Although limited resolution in the neutron time-of-flight spectrometer complicates the interpretation of the Sn data, the overall conclusion that deltasub(nn')(3"-) approx. deltasub(pp')(3"-) is supported by all of the measurements. (orig.).

383

Moessbauer investigation of the magnetic anisotropy and electronic structure of a metallic glass  

International Nuclear Information System (INIS)

The temperature dependence of the average magnetization direction in an Fe_8_0B_2_0 glassy alloy (METGLAS 2605) is investigated by Moessbauer spectroscopy. Moessbauer spectra were recorded between 77 K and 363 K using a conventional constant-acceleration Moessbauer spectrometer with 10 mCi "5"7Co in Pd source. The direction of the easy magnetization is found to be strongly terperature dependent and the out-of-plane component turned to be unusually large. Comparing the magnetic moments some similarities between the electronic structure of the glassy alloy and the Fe_2B and FeB intermetallic compounds are established and discussed. (Sz.N.Z.).

384

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01

385

Joule-Thomson cryogenic cooler with extremely high thermal stability  

Science.gov (United States)

An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.

1991-06-01

386

Ion-induced M X-ray emission from heavy lanthanides  

International Nuclear Information System (INIS)

Thick targets of several heavy lanthanide (Ho-Lu) compounds were bombarded by protons and "3He ions of 3 MeV/amu, and M_#alpha# and M_#beta# X-rays were measured with a crystal spectrometer. Ionization probabilities of the N-shell for zero impact parameter were obtained from the X-ray intensity ratio for proton and "3He ion impacts. A shell dependence of the ionization probability was found in a scaling plot. X-ray spectra of lanthanide compounds were compared and no chemical effect was observed. This result is considered to be due to the fact that the main component of M_#alpha# and M_#beta# lines is for radiative transition after the refilling of the 4f orbit (3d"-"14f"n"+"1 #-># 4f"n) where n denotes the number of 4f electrons of the target atom before ionization. (orig.).

1987-12-01

387

Instrumental neutron activation analysis of copper-molybdenum ores for molybdenum content determination  

International Nuclear Information System (INIS)

An instrumental neutron activation technique of determining molybdenum in ores is based on measuring gamma-activity of the "9"9Mo isotope with the use of planar and coaxial semiconductor spectrometers. A lot consisting of 50 portions, 0.5 g each, is being irradiated for 10 hours by a flow of neutrons with the density of 10"1"2 n/cm"2xsec. On the lot being allowed to stay for 3-4 days, its activity is measured during 1-5 minutes. Monoethalons based upon phenol-formaldehyde resin are used as standards. The sensitivity of the technique is 10"-"4%, reproducibility error being not higher than 10%, efficiency up to 50 portions for a working shift.

388

High-resolution NMR on /sup 29/Si nuclei in acidic zeolites  

Science.gov (United States)

The effect of treatment of Na-forms of zeolites with HCl solutions and of heat treatment of their NH/sub 4/-forms on the stability of aluminum-oxygen tetrahedra has been studied in this work by high-resolution NMR on /sup 29/Si nuclei, using the synthetic zeolites X, Y, and M (mordenite) as the objects of the study. The exchange capacity with respect to Na/sup +/ ions was determined by analyzing the equilibrium solutions after contact of the samples with 0.5 NH/sub 4/Cl solution on a flame photometer. The high-resolution /sup 29/Si NMR spectra of polycrystalline samples were recorded on an SKhR-200 spectrometer with a superconducting solenoid at a frequency of 39.75 MHz with ultrafast mechanical rotation (3 kHz) of the sample at the magic angle to the external magnetic field. The results obtained are given.

1986-12-01

389

High resolution X ray spectroscopy in light antiprotonic atoms  

Energy Technology Data Exchange (ETDEWEB)

At the LEAR facility, CERN, antiprotonic L{alpha} transitions in light elements have been investigated with a focussing crystal spectrometer. The high resolution of the experiment allowed for the first time to resolve in p-barH the 2{sup 3}P{sub 0} state from the close lying states 2{sup 3}P{sub 2}, 2{sup 1}P{sub 1}, and 2{sup 3}P{sub 1}. In p-barD the corresponding transitions were found to be more than an order of magnitude broader. To a large extent the results for p-barH support the meson exchange model.

2000-08-15

390

First observation of psi(2S)-->K_S K_L  

CERN Document Server

The decay psi(2S)-->K_S K_L is observed for the first time using psi(2S) data collected with the Beijing Spectrometer (BESII) at the Beijing Electron Positron Collider (BEPC); the branching ratio is determined to be B(psi(2S)-->K_S K_L) = (5.24\\pm 0.47 \\pm 0.48)\\times 10^{-5}. Compared with J/psi-->K_S K_L, the psi(2S) branching ratio is enhanced relative to the prediction of the perturbative QCD ``12%'' rule. The result, together with the branching ratios of psi(2S) decays to other pseudoscalar meson pairs (\\pi^+\\pi^- and K^+K^-), is used to investigate the relative phase between the three-gluon and the one-photon annihilation amplitudes of psi(2S) decays.

2003-01-01

391

Exclusive ?0 electroproduction on transversely polarized protons  

International Nuclear Information System (INIS)

The exclusive electroproduction of ?0 mesons was studied with the HERMES spectrometer at the DESY laboratory by scattering 27.6 GeV positron and electron beams off a transversely polarized hydrogen target. Spin density matrix elements for this process were determined from the measured production- and decay-angle distributions of the produced ?0 mesons. These matrix elements embody information on helicity transfer and the validity of s-channel helicity conservation in the case of a transversely polarized target. From the spin density matrix elements, the leading-twist term in the single-spin asymmetry was calculated separately for longitudinally and transversely polarized ?0 mesons. Neglecting s-channel helicity changing matrix elements, results for the former can be compared to calculations based on generalized parton distributions, which are sensitive to the contribution of the total angular momentum of the quarks to the proton spin.

2009-08-17

392

Elastic and inelastic scattering of "1"4C from medium heavy nuclei  

International Nuclear Information System (INIS)

The elastic and inelastic scattering of "1"4C at 51 MeV from targets of "4"0Ca, "5"6Fe, "6"0Ni, "6"6Zn and "8"8Sr has been measured using a Q3D spectrometer. The "1"4C-nucleus potentials have been derived by optical-model analysis of the observed elastic scattering; the inelastic scattering differential cross sections were interpreted in the distorted-wave Born approximation and also in the coupled-channels approach. The analysis yields "1"4C-nucleus potentials that closely resemble "1"2sup(,)"1"3C and "1"6O potentials. (orig.).

393

Chemical and morphological characterization of mesoporous material supported copper oxide nanoparticles for potential application  

British Library Electronic Table of Contents (United Kingdom)

SBA-15 supported nano-scaled copper oxide was synthesized by impregnation method via ultrasonic-assisted route. The removal test from gas mixture containing 0.1?vol.% hydrogen sulfide was carried out over this material at atmospheric conditions. The effects of the chemical nature of copper oxide and the textural properties of the material on removal capacity were studied. The materials before and after the removal test were analyzed by nitrogen adsorption, X-ray diffraction, Transmission Electron Microscope, X-ray photoelectron Spectroscopy, Fourier Transform Infrared Spectrometer and Inductive Coupled Plasma. The results showed that copper species are located predominantly in mesopore channels, existing as copper oxide nanoparticles. Mesopores are active sites for removal reaction. The ou...

2011-01-01

394

Cavity ringdown spectroscopy with a continuous-wave laser: calculation of coupling efficiency and a new spectrometer design.  

Science.gov (United States)

For the efficient operation of a cavity ringdown spectroscopy (CRDS) system utilized with a continuous-wave (cw) laser, we numerically analyze the coupling efficiency of a cw laser to a ringdown cavity in terms of changes in the scanning rate, the laser linewidth, and the mirror reflectivity. We also demonstrate a new simple design for a CRDS system that can produce a CRDS signal with only a piezoelectric transducer (PZT), without the acousto-optic modulator that is usually adopted to switch off the cw laser beam that enters the cavity. Furthermore, we investigate the feasibility of the cw CRDS technique with a fast-scanning PZT by recording a CRDS spectrum of acetylene overtones. The detection sensitivity that corresponds to the noise-equivalent absorption is found to be approximately 3 x 10(-9)/cm. PMID:18305817

1999-03-20

395

A polarized neutron reflectometry study of the spin glass freezing in a 29 nm thick AuFe film  

Energy Technology Data Exchange (ETDEWEB)

We performed polarized neutron reflectometry (PNR) experiments on a 29 nm thick Au{sub 93}Fe{sub 7} film in a temperature range from 295 K down to 2 K in a vertical magnetic field up to 6 T. These high-field experiments were performed on the C5 spectrometer in Chalk River, Canada, using a split-pair cryomagnet. The magnetization as determined by PNR can be described with a Brillouin function from 295 K down to 50 K assuming the magnetic moment of isolated Fe atoms, i.e. 4{mu}{sub B} per Fe atom. Below 50 K the onset of the spin-glass freezing is observed as a strong deviation from this Brillouin type behavior of isolated atoms.

2007-07-15

396

A novel electrochemical alkylation of aniline with methanol over Zn/Cu salts modified kaolin  

British Library Electronic Table of Contents (United Kingdom)

A novel liquid phase alkylation of aniline with methanol over Zn/Cu salts modified kaolin assisted with a pair of porous carbon electrode in slurry-bed reactor under constant current intensity, room temperature and atmospheric pressure was reported. The Zn/Cu salts modified kaolin catalysts were synthesized and characterized by infrared spectrometer (IR), powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), which showed that the transition metals were completely supported on kaolins structure and formed a pored one. The effect parameters, such as initial pH, electrolysis time, metal ratio with kaolin and salts composition in this electrochemical catalytic system, were studied. The procedure was inspected by ultraviolet-visible spectrum (UV-vis), and the product distributi...

2008-01-01

397

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

398

In vitro percutaneous absorption of metal compounds.  

Science.gov (United States)

It is well known that contact with metals can be responsible for allergic contact dermatitis; also, there is experimental evidence that nickel ions are readily available on the surface of used coins containing nickel and copper. The aim of this study was to prove that metal powders of nickel (Ni), cobalt (Co) and chromium (Cr) dispersed in synthetic sweat are oxidised into respective ions that can permeate the skin. Suspensions of 5 g of metal powder (Ni, Co and Cr) in 100 mL of synthetic sweat at pH 6.5 were prepared and shaken with a stirring plate at room temperature for 30 min. Human skin membranes were set up in Franz-diffusion cells and 2 mL of the freshly made suspension were applied to the outer surface of the skin for 24h. The appearance of metal ions in the aqueous receptor phase (NaCl 0.9%) was quantified by Electro Thermal Atomic Absorption Spectroscopy (ETAAS). Also, metals ions were analysed using Differential Pulse Polarography (DDP), Differential Pulse Voltammetry (DPV) ...

2007-02-23

399

Neutrino masses in the Lepton Number Violating MSSM  

CERN Document Server

We consider the most general supersymmetric model with minimal particle content and an additional discrete Z_3 symmetry (instead of R-parity), which allows lepton number violating terms and results in non-zero Majorana neutrino masses. We investigate whether the currently measured values for lepton masses and mixing can be reproduced. We set up a framework in which Lagrangian parameters can be initialised without recourse to assumptions concerning trilinear or bilinear superpotential terms, CP-conservation or intergenerational mixing and analyse in detail the one loop corrections to the neutrino masses. We present scenarios in which the experimental data are reproduced and show the effect varying lepton number violating couplings has on the predicted atmospheric and solar mass^2 differences. We find that with bilinear lepton number violating couplings in the superpotential of the order 1 MeV the ...

2006-01-01

400

Implications of the dwarfs spheroidal galaxy mass-metallicity relation  

International Nuclear Information System (INIS)

The properties of the mass-metallicity relation among dwarf spheroidal galaxies are discussed in terms of a model which assumes that the internal chemical evolution of the dwarf spheroidals was promoted by supernova activity. The model can be used to explain the observed dwarf spheroidal mass-metallicity relation assuming the present mass of these systems M sub s is proportional to their initial masses M as M sub s varies according to a power-law index of exp 7/4. It is inferred from the power-law dependence of M on the proto-cloud radius that the most massive dwarf spheroids were formed from the densest clouds. The observed slope of the mass-metallicity relation for dwarf spheroidal galaxies is found to be significantly different from theoretical estimates of this slope for elliptical galaxies. It is suggested that the difference may imply that spheroidal dwarfs and elliptical ...

401

Dynamic mass density and acoustic metamaterials  

Energy Technology Data Exchange (ETDEWEB)

Mass density of a composite is generally taken as the volume-averaged value of components' densities. Moreover, the same volume-averaged mass density is usually used to calculate the wave speed in the long-wavelength limit, i.e., where the wavelength is much larger than the size of the inhomogeneities. In this paper, we show via rigorous derivation that the dynamic mass density used in the calculation of (long-wavelength) wave speed can differ significantly from the static volume-averaged value. This recognition is shown to yield an excellent account of some recent experimental data, as well as to make possible the realization of acoustic metamaterials. Physical reason for the difference between two mass densities is attributed to the relative motion between the components. That is, the implicit assumption-that all components in a composite must move uniformly in the long-wavelength limit-can ...

2007-05-15

402

Cosmic evolution of the atomic and molecular gas content of galaxies  

CERN Document Server

We study the evolution of the cold gas content of galaxies by splitting the interstellar medium into its atomic and molecular hydrogen components, using the galaxy formation model GALFORM in the LCDM framework. We calculate the molecular-to-atomic hydrogen mass ratio, H2/HI, in each galaxy using two different approaches; the pressure-based empirical relation of Blitz & Rosolowsky and the theoretical model of Krumholz, McKeee & Tumlinson, and apply them to consistently calculate the star formation rates of galaxies. We find that the model based on the Blitz & Rosolowsky law predicts an HI mass function, CO(1-0) luminosity function, correlations between the H2/HI ratio and stellar and cold gas mass, and infrared-CO luminosity relation in good agreement with local and high redshift observations. The HI mass function evolves weakly with redshift, with the number density of high ...

2011-01-01

403

ADIABATIC MASS LOSS AND THE OUTCOME OF THE COMMON ENVELOPE PHASE OF BINARY EVOLUTION  

International Nuclear Information System (INIS)

We have developed a new method for calculating common envelope (CE) events based on explicit consideration of the donor star's structural response to adiabatic mass loss. In contrast to existing CE prescriptions, which specify a priori the donor's remnant mass, we determine this quantity self-consistently and find that it depends on binary and CE parameters. This aspect of our model is particularly important to realistic modeling for upper main-sequence star donors without strongly degenerate cores (and hence without a clear core/envelope boundary). We illustrate the central features of our method by considering CE events involving 10 M_s_u_n donors on or before their red giant branch. For such donors, the remnant core mass can be as much as 30% larger than the star's He-core mass. Applied across a population of such binaries, our methodology results in a significantly broader remnant ...

2010-08-10

404

A ~5 M_earth Super-Earth Orbiting GJ 436?: The Power of Near-Grazing Transits  

CERN Document Server

Most of the presently identified exoplanets have masses similar to that of Jupiter and therefore are assumed to be gaseous objects. With the ever-increasing interest in discovering lower-mass planets, several of the so-called super-Earths (i.e., with masses in the interval 1 M_earth < M < 10 M_earth), which are predicted to be rocky, have already been found. Here we report the possible discovery of a planet around the M-type star GJ 436 with a minimum mass of 4.8+/-0.6 M_earth and a true mass of ~5 M_earth, which makes it the least massive planet around a main-sequence star found to date. In contrast with other discoveries, the planet is identified from its perturbations on an inner Neptune-mass transiting planet (GJ 436b), by pumping eccentricity and producing secular variations in the orbital inclination. Analysis of published radial velocity ...

2008-01-01

405

Stability of Few-Charge Systems in Quantum Mechanics  

CERN Document Server

We consider non-relativistic systems in quantum mechanics interacting through the Coulomb potential, and discuss the existence of bound states which are stable against spontaneous dissociation into smaller atoms or ions. We review the studies that have been made of specific mass configurations and also the properties of the domain of stability in the space of masses or inverse masses. These rigorous results are supplemented by numerical investigations using accurate variational methods. A section is devoted to systems of three arbitrary charges and another to molecules in a world with two space-dimensions.

2004-01-01

406

Shell effects in the symmetric-modal fission of pre-actinide nuclei  

International Nuclear Information System (INIS)

Mass distributions of fragments in the low-energy fission of nuclei from "1"8"7Ir to "2"1"3At have been analysed. This analysis has shown that shell effects in symmetric-mode fragment mass yields from the fission of pre-actinide nuclei could be described if one assumes the existence of two strongly deformed neutron shells in the arising fragments with neutron numbers N_1#approx#52 and N_2#approx#68. A new method has been proposed for quantitatively describing the mass distributions of the symmetric fission mode for pre-actinides with A#approx#180-220. (orig.)

1998-09-21

407

Quantification of uranium transport away from firing sites at Los Alamos National Laboratory: A mass balance approach  

Science.gov (United States)

Investigations were conducted at Los Alamos National Laboratory to quantify the extent of migration of depleted uranium away from firing sites. Extensive sampling of air particles, soil, sediment, and water was conducted to establish the magnitude of uranium contamination throughout one watershed. The uranium source term was estimated, and mass balance calculations were performed to compare the percentage of migrated uranium with original expenditures. Mass balance calculations can be powerful in identification of the extent of waste migration and used as an aid in planning future waste investigations.

1992-02-01

408

Principle, classification and functions of geochemical modeling codes  

International Nuclear Information System (INIS)

Geochemical model is a kind of concept model which describes geochemical processes by means of chemical reaction equations and mathematical formula, and the software based on the concept model are called geochemical modeling code. Geochemical modeling codes can be divided into three categories: mass equilibrium, mass transfer and mass transport code. The major functions of geochemical codes include the calculation of forms of occurrence of elements, the prediction of direction of various geochemical reaction, the dissolution and precipitation of elements, the pH and Eh value, the rate and path of geochemical reaction in aqueous solution.

409

Phenomenological implication of KamLAND on lepton mass matrices  

CERN Document Server

By using a model independent Monte Carlo approach, we study the possible structure of charged and neutral lepton mass matrices, under the assumption of an U(2) horizontal symmetry (additional to the usual Standard Model ones) involving the light fermion generations. We assume the most general Majorana mass matrix for neutrinos. We update the results of our previous similar study, by inserting in the analysis the recent KamLAND data, that contributed to find a final solution to the Solar neutrino problem. The introduction of the new experimental data reduce the allowed regions in the nine dimensional space parameters, and show that our procedure gives stable solutions.

2003-01-01

410

Persistence of the N=28 shell closure far from stability  

Science.gov (United States)

The masses of 16 neutron-rich nuclei in the mass range from 35 to 45 have been measured using a direct time of flight technique following the fragmentation of a {sup 48}Ca beam at 60 MeV/nucleon. The masses of {sup 35,36}Mg, {sup 38}Al, {sup 39,40}Si, {sup 42,43}P and {sup 43,44}S are reported for the first time. Preliminary analysis shows that the N=28 shell closure persists, even if weakened by the large neutron excess.

1998-12-21

411

Persistence of the N=28 shell closure far from stability  

International Nuclear Information System (INIS)

The masses of 16 neutron-rich nuclei in the mass range from 35 to 45 have been measured using a direct time of flight technique following the fragmentation of a "4"8Ca beam at 60 MeV/nucleon. The masses of "3"5","3"6Mg, "3"8Al, "3"9","4"0Si, "4"2","4"3P and "4"3","4"4S are reported for the first time. Preliminary analysis shows that the N=28 shell closure persists, even if weakened by the large neutron excess.

1998-12-21

412

Nuclear material accountability by isotope dilution mass spectrometry  

International Nuclear Information System (INIS)

This paper discusses the mass spectrometric system that has been developed at the ICPP (Idaho Chemical Processing Plant) to meet the multiple constraints of U accountability, high sample load, and plant process control. The measurement system must produce high-quality accountability results while maintaining high sample throughput and reasonable turnaround time. The mass spectrometric system that has evolved to meet these demands includes extensive operator training, routine quality control checks, and continuing review of performance. 7 refs.

1981-07-13

413

Intermediate mass Higgs study at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

414

Intermediate mass Higgs study at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

415

Inclusive photoproduction of D{sup *{+-}} mesons at next-to-leading order in the general-mass variable-flavor-number scheme  

Energy Technology Data Exchange (ETDEWEB)

We discuss the inclusive production of D{sup *{+-}} mesons in {gamma}p collisions at DESY HERA, based on a calculation at next-to-leading order in the general-mass variable-flavor-number scheme. In this approach, MS subtraction is applied in such a way that large logarithmic corrections are resummed in universal parton distribution and fragmentation functions and finite mass terms are taken into account. We present detailed numerical results for a comparison with data obtained at HERA and discuss various sources of theoretical uncertainties. (orig.)

2009-02-15

416

Free convection heat and mass transfer to steady flow in a semi-infinite vertical porous medium  

International Nuclear Information System (INIS)

Analytical solutions are derived for a flow in a semi-infinite vertical porous medium with heat and mass transfer. When the temperature and mass concentration are uniform a constant pressure is possible and sustains a fully developed flow. Thereafter there is a small perturbation on the wall temperature and concentration and the subsequent two-dimensional problem is tackled for a large Prandtl number, free convection parameters and small Reynolds number. The heat transfer rate at the wall is discussed quantitatively. (author). 4 refs.

2010-06-01

417

Effect of additives in the positive active mass of lead batteries. Zur Wirkung von Zusaetzen in der positiven Aktivmasse des Bleiakkumulators  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the capacity and service life of cathodes, the effect of carboxy-methyl cellulose, soot, silica gel and fibres was examined. Structural tests and electrical and electro-chemical measurements are used for this. The additives can affect crystallization in the manufacturing stage of the electrodes and can increase the storage capacity for water and the electronic conductivity. They act to stabilize the mass in cyclic operation. Soot additive has little effect on the properties of the electrode, but the other substances increase the service life or the use of the mass. (LU).

1984-01-01

418

Anisotropic mass density by two-dimensional acoustic metamaterials  

Energy Technology Data Exchange (ETDEWEB)

We show that specially designed two-dimensional arrangements of full elastic cylinders embedded in a nonviscous fluid or gas define (in the homogenization limit) a new class of acoustic metamaterials characterized by a dynamical effective mass density that is anisotropic. Here, analytic expressions for the dynamical mass density and the effective sound velocity tensors are derived in the long wavelength limit. Both show an explicit dependence on the lattice filling fraction, the elastic properties of cylinders relative to the background, their positions in the unit cell, and their multiple scattering interactions. Several examples of these metamaterials are reported and discussed.

2008-02-15

419

A mathematical model for a thermally coupled humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

The humidification?dehumidification process is an interesting technique that has been adapted for water desalination. Previous works experimentally investigated desalination processes in the shell and tube columns, where the humidification and dehumidification were thermally coupled and simultaneously performed at the tube and shell sides, respectively. In this work, a comprehensive steady-state mathematical model was developed for such a humidification?dehumidification desalination process by taking into account the heat and mass balances on both sides of the desalting column, the mass transfer rate at the humidification side, and the heat transfer rate between the dehumidification side and humidification side. Meanwhile, the mass transfer coefficient at the humidification side and the to...

2006-01-01

420

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of the two ...

2010-10-01

421

Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination  

Energy Technology Data Exchange (ETDEWEB)

The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...

2000-07-01

422

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the ...

1997-05-01

423

Experimental determination of line strengths for selected carbon monoxide and carbon dioxide absorption lines at temperatures between 295 and 1250 K  

Energy Technology Data Exchange (ETDEWEB)

Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO[sub 2] absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the [ital P] branch of the fundamental absorption band (2150--1950 cm[sup [minus]1]) while the CO[sub 2] vibrational-rotational lines were from the far wing of the [ital R] branch of the [nu][sub 3] fundamental band (2395--2380 cm[sup [minus]1]). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO[sub 2]/N[sub 2] gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite resolution of the spectrometer and for peak ...

1994-11-01

424

Experimental determination of line strengths for selected carbon monoxide and carbon dioxide absorption lines at temperatures between 295 and 1250 K  

International Nuclear Information System (INIS)

Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO_2 absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the P branch of the fundamental absorption band (2150--1950 cm"-"1) while the CO_2 vibrational-rotational lines were from the far wing of the R branch of the #nu#_3 fundamental band (2395--2380 cm"-"1). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO_2/N_2 gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite resolution of the spectrometer and for peak overlap. Line strength measurements were made from the corrected ...

425

Development of a Bragg curve spectrometer (BCS) for fragment spectroscopy from neutron and proton induced reactions  

Energy Technology Data Exchange (ETDEWEB)

Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the saturation property by using {sup 241}Am {alpha} ...

2002-09-01

426

Determination of the Integral/SPI instrumental response and his application to the observation of gamma ray lines in the Vela region; Determination de la reponse instrumentale du spectrometre INTEGRAL/SPI et application a l'observation des raies gamma de la region des Voiles  

Energy Technology Data Exchange (ETDEWEB)

The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region ...

2005-01-15

427

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation measurement capabilities ...

1995-11-01

428

Absence of isoscalar monopole strength in {sup 56}Fe and {sup 58}Ni  

Energy Technology Data Exchange (ETDEWEB)

Measurements with 240 MeV {alpha} particle inelastic scattering with excellent peak/background ratios at small scattering angles including 0{degrees} were made on {sup 56}Fe and {sup 58}Ni using the multipole-dipole-multipole spectrometer at Texas A&M University. Beam was delivered to the spectrometer through a beam analysis system having two bends of 88{degrees} and 87{degrees} respectively. A slit placed after the first 88{degrees} bend was used to define the beam. Slits placed after the second bend (87{degrees}) were used to eliminate slit scattered particles. Comparison of the results of a multiple peak fit to the{sup 58}Ni spectra after continuum subtraction to DWBA calculations revealed about 32% of the E0 EWSR and 58% of the E2 EWSR in the peak, in agreement with previous works. Fits to the angular distribution of the continuum for E{sub x} = 25 MeV show that <15% of the E0 EWSR is present in the continuum. Hence 50% of the EO ...

1995-10-01

429

Using highly excited baryons to catch the quark mass  

CERN Document Server

Chiral symmetry in QCD can be simultaneously in Wigner and Goldstone modes, depending on the part of the spectrum examined. The transition regime between both, exploiting for example the onset of parity doubling in the high baryon spectrum, can be used to probe the running quark mass in the mid-IR power-law regime. In passing we also argue that three-quark states naturally group into same-flavor quartets, split into two parity doublets, all splittings decreasing high in the spectrum. We propose that a measurement of masses of high-partial wave Delta* resonances should be sufficient to unambiguously establish the approximate degeneracy and see the quark mass running. We test these concepts with the first computation of the spectrum of high-J excited baryons in a chiral-invariant quark model.

2009-01-01

430

Tracheal compression by mediastinal masses in children: CT evaluation  

Energy Technology Data Exchange (ETDEWEB)

Chest computed tomography (CT) was valuable in detecting extrinsic tracheal compression by mediastinal masses in two pediatric patients. This prompted an independent evaluation by CT of 14 children with masses involving the middle mediastinum and possible intrathoracic tracheal narrowing. Computer programs permit precise calculation of tracheal cross-sectional areas. Any apparent decrease in tracheal area may be compared with CT-derived data in normal children. Chest CT not only demonstrates the presence of extrinsic airway compression in pediatric patients with mediastinal masses, but also is capable of precisely measuring the extent of this narrowing. This method identifies children at potential risk for respiratory compromise and may aid in subsequent therapy.

1983-10-01

431

Three generation vacuum oscillations and the solar neutrino problem  

CERN Document Server

We investigate the solar neutrino problem in the scenario of three generation neutrino oscillation hypothesis, taking into account other phenomenological constraints to the neutrino mixing and mass parameters.

1994-01-01

432

The mass dependence of the signal peak height of a Bragg-curve ionization chamber  

International Nuclear Information System (INIS)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).

433

The effect of a concurrent gas flow on gas-liquid mass transfer  

Science.gov (United States)

A theory for the mass transfer process was developed. It was assumed that the largest convective motions in the flow control the rate of mass transfer. Measurements of mass transfer coefficients for the absorption of oxygen by water films were made for concurrent flows in a horizontal rectangular channel, and for concurrent and free-falling downflow in a one-inch pipe. The measured values of the Sherwood number for concurrent flows were up to three times as great as would be predicted from this relation. This increase in Sherwood number was correlated with a dimensionless group similar to a Martinelli parameter which is characteristic of two phase flows. An explanation for this effect is given in terms of the way that the scales of the convective motions are related to bulk flow parameters.

1977-01-01

435

The Case for Reactive Mass Oral Cholera Vaccinations  

UK PubMed Central (United Kingdom)

IntroductionThe outbreak of cholera in Zimbabwe intensified interest in the control and prevention of cholera. While there is agreement that safe water, sanitation, and personal...Full Text Available

436

Test Planning Guide for ASF Facilities  

Science.gov (United States)

15 to 75% of the gun barrel diameter. Similarly, model masses typically vary from 0.01 to 100 .... taining acceptable levels of gun barrel erosion. The ...

437

Stars, their evolution and their stability  

Energy Technology Data Exchange (ETDEWEB)

The Nobel lecture of Chandrasekhar is printed in which he describes the basic processes that determine the life history of a star with particular emphasis on the roles of stellar mass and radiation pressure. (AIP)

1984-04-01

438

Sacral haemangioma as a cause of coccydynia  

International Nuclear Information System (INIS)

We report a 55-year-old woman with coccydynia due to a sacral mass. The histological diagnosis was haemangioma. The MRI findings and the unusual location of this lesion are discussed. (orig.)

1998-08-01

439

Renormalization Group Running of Lepton Mixing Parameters in See-Saw Models with $S_4$ Flavor Symmetry  

CERN Document Server

We study the renormalization group running of the tri-bimaximal mixing predicted by the two typical $S_4$ flavor models at leading order. Although the textures of the mass matrices are completely different, the evolution of neutrino mass and mixing parameters is found to display approximately the same pattern. For both normal hierarchy and inverted hierarchy spectrum, the quantum corrections to both atmospheric and reactor neutrino mixing angles are so small that can be neglected. The evolution of solar mixing angle $\\theta_{12}$ depends on $\\tan\\beta$ and mass spectrum, the deviation from its tri-bimaximal value could be large. Taking into account the renormalization group running effect, the neutrino spectrum is constrained by experimental data on $\\theta_{12}$ and the inverted hierarchy spectrum is disfavored for large $\\tan\\beta$. The evolution of light neutrino masses is approximately ...

2010-01-01

440

Pulsational instability in massive stars: implications for ...  

Science.gov (United States)

sive star evolution based on our new calculations of this pulsational instability, where the initial mass of SNe progenitors increases according to the ...

441

PROCEEDINGS OF THE 1966 HEAT TRANSFER AND FLUID ...  

Science.gov (United States)

... mass of gray gas by thermal radiation; An experimental study of the turbulent wake behind a cone at M = 5; Heat transfer augmentation by steady ...

442

On the two-loop Yukawa corrections to the MSSM Higgs boson masses at large tan(beta)  

CERN Document Server

We complete the effective potential calculation of the two-loop, top/bottom Yukawa corrections to the Higgs boson masses in the Minimal Supersymmetric Standard Model, by computing the O(at^2 + at*ab + ab^2) contributions for arbitrary values of the bottom Yukawa coupling. We also compute the corrections to the minimization conditions of the effective potential at the same perturbative order. Our results extend the existing O(at^2) calculation, and are relevant in regions of the parameter space corresponding to tan(beta) >> 1. We extend to the Yukawa corrections a convenient renormalization scheme, previously proposed for the O(ab*as) corrections, that avoids unphysically large threshold effects associated with the bottom mass and absorbs the bulk of the corrections into the one-loop expression. For large values of tan(beta), the new contributions can account for a variation of several GeV in the lightest Higgs boson ...

2003-01-01

443

On the disrupted magnetic braking model for the period gap of cataclysmic variables  

International Nuclear Information System (INIS)

The disrupted magnetic braking theory for the period gap of cataclysmic variable systems is used to study the binary evolution of low-mass main-sequence-like stars with white dwarf companions. The model is able to reproduce the observed location and width of the gap provided that the average mass transfer rates above the upper edge of the gap are greater than about 1.9 x 10 to the -9th solar masses/yr. For the case of angular momentum loss by magnetic braking, the slope of the mass transfer rate with respect to orbital period is shown to range from 3.4 to 3.7. For the evolutionary sequences considered, the He-3 abundance at the surface of the secondary exceeds 0.0015 after the complete mixing phase, resulting in modifications in the nuclear burning development of nova explosions. 31 refs.

444

Nuclear data sheets for A=242  

International Nuclear Information System (INIS)

The available nuclear structure information for all nuclei with mass number A=242 is presented. Various decay and reaction data are evaluated. Adopted data, levels, spin and parity assignments are given.

445

Nuclear data sheets for A = 101  

Energy Technology Data Exchange (ETDEWEB)

Detailed level and decay schemes are presented for the nuclei of the A = 101 mass chain. The level properties obtained from decay and reaction experiments are shown in the drawings. Experimental methods, references, and comments are given in the text.

1985-08-01

446

Nuclear data sheets for A = 101  

International Nuclear Information System (INIS)

Detailed level and decay schemes are presented for the nuclei of the A = 101 mass chain. The level properties obtained from decay and reaction experiments are shown in the drawings. Experimental methods, references, and comments are given in the text.

447

Newton's first law and the existence of free tachyons  

International Nuclear Information System (INIS)

NEWTON's first law prohibits the coupling of free tachyons to ordinary matter, if it is interpreted as selection rule interdicting emission without change of the rest-mass of the emitting system.

448

National Military Strategy to Combat Weapons of Mass ...  

Science.gov (United States)

... and regional land, sea, air, and space-based systems, and ... means of delivery of weapons where such ... a separable and divisible part of the weapon. ...

2006-02-13

449

N95. 14209 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

coupled heat/mass transfer Stefan problem. Taking the diffusion coefficient of Bi as a free parameter, the best fit was observed for the published value, ...

450

Mass dependence of the signal peak height of a Bragg-curve ionization chamber  

Energy Technology Data Exchange (ETDEWEB)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.

1985-01-01

451

Improving the sheared edge in the blanking of commercial AZ31 sheet through texture modification  

British Library Electronic Table of Contents (United Kingdom)

Commercial rolled magnesium sheets of alloys AZ31 (Mg-3 mass%Al-1 mass%Zn) and ZE10 (Mg-1 mass% Zn-<1 mass% Rare Earths) in O-temper condition were used for blanking experiments near room temperature. A serrated fracture surface can be observed in case of AZ31 but not in case of ZE10. During the shearing process of the AZ31 sheet, many micro cracks parallel to the sheet plane are generated in the shearing zone. These micro cracks lead to the formation of loose particles during the shearing operation, which interfere with further processing of the part and incur additional costs by increasing the scrap rate. It is found that the strong basal texture of this alloy is an important reason for the generation of such serrated cracks. In this paper a new method of selective texture modification i...

2011-01-01

452

Hadron Calorimeter Endcap  

International Science & Technology Center (ISTC)

Development of the Technology and Control of Electron-Beam Welding Procedure and Production of Full Scale Sector of Endcap CMS Hadron Calorimeter. Preparation for Mass Production.

453

GAMMA SPECTRA AND PERIODS OF FOUR ODD-A ISOTOPES OF TUNGSTEN AND TANTALUM  

Science.gov (United States)

The gamma spectra and lifetimes of the Ta and W isotopes havimg mass numbers 173, 175, 177, and 179 are determined. (T.F.H.)

1963-06-01

454

Eighth Goddard Conference on Mass Storage Systems and Technologies ...  

Science.gov (United States)

f4 f5 f1 f2. (a) Overall process decompress ...... involved the shortest learning curve, was available on several platforms, and was ...

455

Effect of mass transport on the determination of corrosion rates from polarization measurements  

Energy Technology Data Exchange (ETDEWEB)

Many methods have been proposed for the determination of the corrosion current density from polarization curves; the two most commonly used ones are the three-point method and the curve-fitting method. The basis of these methods is a polarization equation that was derived for the complete absence of mass-transport effect or considers the cathodic partial reaction to be under complete mass-transport control. The mixed-control case has been much less investigated, even though this case may quite frequently reflect practical situations. A completely generalized polarization equation is proposed that can be used as a basis for curve-fitting data evaluation under any conditions. This equation was used to determine the error caused by the neglect of mass-transport effect in conventional data evaluation.

1986-10-01

456

Derated Application of Parts for ESD (Electronic Systems ...  

Science.gov (United States)

... o Application - Aluminum electrolytic capacitors provide the tallest voluse, mass and cost per microfarad except for tan- , talum capacitors. ...

1985-03-01

457

Derated Application of Parts for (Electronic System Division) ...  

Science.gov (United States)

... o Application - Aluminum electrolytic capacitors provide the smallest volume, mass and cost per microfarad except for tan- talum capacitors. ...

1983-09-01

458

Defense Horizons. Number 18, October 2002. High-Energy ...  

Science.gov (United States)

... assets, particularly against ballistic missiles with weapons of mass ... more con- ventional missile and gun weapon systems. ... Similarly, space-based ...

2002-10-01

459

Cuba's response to the HIV epidemic.  

UK PubMed Central (United Kingdom)

BACKGROUND: Cuba's response to the human immunodeficiency virus (HIV) epidemic has been to conduct mass testing of the population to ascertain seroprevalence, to enforce mandatory relative quarantine...Full Text Available

1991-05-01

460

Augmentation of heat and mass transfer  

Energy Technology Data Exchange (ETDEWEB)

This is the first text and reference book to be devoted completely to the very important and timely subject of heat transfer augmentation. This book is of equal appeal to both researchers and designers of heat transfer equipment.

1986-01-01

461

APOD: 2009 April 23 ... - Astronomy Picture of the Day - NASA  

Science.gov (United States)

Apr 23, 2009 ... Wolf-Rayet stars have over 20 times the mass of the Sun and are thought to be in a brief, pre-supernova phase of massive star evolution. ...

462

A new method of determining the inclination angle in interacting binaries  

CERN Document Server

We describe a method of determining the system parameters in non-eclipsing interacting binaries. We find that the extent to which an observer sees the shape of the Roche-lobe of the secondary star governs the amount of distortion of the absorption line profiles. The width and degree of asymmetry of the phase-resolved absorption line profiles show a characteristic shape, which depends primarily on the binary inclination and gravity darkening exponent. We show that, in principle, by obtaining high spectral and time resolution spectra of quiescent cataclysmic variables or low mass X-ray binaries in which the mass-losing star is visible, fitting the shape of absorption line profiles will allow one to determine not only the mass function of the binary, but also the binary inclination and hence the mass of the binary components.

1998-01-01

463

A gravitational diffusion model without dark matter  

UK PubMed Central (United Kingdom)

In this model, without dark matter, the flat rotation curves of galaxies and the mass-to-light ratios of clusters of galaxies are described quantitatively. The hypothesis is that the agent of gravitational...Full Text Available

1998-03-31

464

A case of Meigs syndrome mimicking metastatic breast carcinoma  

UK PubMed Central (United Kingdom)

BackgroundAdnexal masses are not uncommon in patients with breast cancer. Breast cancer and ovarian malignancies are known to be associated. In patients with breast cancer and co-existing...Full Text Available

465

Where Do We Go from Here? Prevalence of Trachoma Three Years after Stopping Mass Distribution of Antibiotics in the Regions of Kayes and Koulikoro, Mali  

UK PubMed Central (United Kingdom)

ObjectivesA national survey in 1997 demonstrated that trachoma was endemic in Mali. Interventions to control trachoma including mass drug administration (MDA) with azithromycin were...Full Text Available

466

Transient burnout in flow reduction condition  

International Nuclear Information System (INIS)

A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author).

467

Theoretical study of subwavelength imaging by acoustic metamaterial slabs  

CERN Document Server

We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.

2009-01-01

468

The asymmetric rotator model applied to odd-mass iridium isotopes  

International Nuclear Information System (INIS)

The method of inversion of the eigenvalue problem previously developped for nuclei with axial symmetry is extended to asymmetric equilibrium shapes. This new approach to the asymmetric rotator model is applied to the odd-mass Iridium isotopes. A satisfactory and coherent description of the observed energy spectra is obtained, especially for the lighter isotopes. (orig.).

469

Structure functions at low Q^2: higher twists and target mass effects  

Energy Technology Data Exchange (ETDEWEB)

We review the physics of structure functions at low Q{sup 2}, focusing on the phenomenon of quark-hadron duality and the resonance-scaling transition, both phenomenologically and in the context of quark models. We also present a new implementation of target mass corrections to nucleon structure functions which, unlike existing treatments, has the correct kinematic threshold behavior at finite Q{sup 2} in the x -> 1 limit.

2006-05-22

470

Simultaneous Gas Chromatography-Mass Spectrometry Quantification of Endogenous [12C]- and Applied [13C]Indole-3yl-Acetic Acid Levels in Growing Maize Roots  

UK PubMed Central (United Kingdom)

The use of stable indole-3yl-acetic acid (IAA) labeled by 6 atoms of 13C allowed, after [13C]IAA treatment, simultaneous gas chromatography-mass spectrometry quantifications of...Full Text Available

1991-01-01

471

Self-consistent nonperturbative effect of string fragmentation on superstring mass spectra  

Energy Technology Data Exchange (ETDEWEB)

Using a simple model for soft self-consistent nonperturbative string fragmentation-recombination loops, we find that, in an open-string theory, ground-state particles necessary for the standard model either become tachyons or acquire large (Planck-scale) masses, making them unacceptable for sub-Planck-scale phenomenology. No comparable difficulties are evident for closed-string theories.

1989-02-01

472

Scattering of scalar tardyons and tachyons from a Schwarzschild black hole  

Energy Technology Data Exchange (ETDEWEB)

The Klein-Gordan equation in the background of the Schwarzschild curved space-time is considered and the scattering of radial tardyons and tachyons from a black hole is studied. It is shown that black holes of mass below 7x10/sup 14/g may contain bound states of tardyons of pion mass which will be unstable on account of the presence of an attractive r/sup -4/ term.

1982-10-01

473

Scattering of scalar tardyons and tachyons from a Schwarzschild black hole  

International Nuclear Information System (INIS)

The Klein-Gordan equation in the background of the Schwarzschild curved space-time is considered and the scattering of radial tardyons and tachyons from a black hole is studied. It is shown that black holes of mass below 7x10"1"4g may contain bound states of tardyons of pion mass which will be unstable on account of the presence of an attractive r"-"4 term. (author).

474

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

475

Relativistic kinetics of baryon production in the big bang  

Energy Technology Data Exchange (ETDEWEB)

The baryogenesis process in the early hot universe is investigated by means of relativistic kinetic theory. An exact solution to the kinetic equations for supermassive bosons serves to refine previous results: the optimum baryon-production domain is now complemented by bosons of low mass, thus removing the cosmological lower bound that had limited the mass of superheavy bosons. 14 references.

1985-08-01

476

Quantum tachyons in Schwarzschild space-time  

Energy Technology Data Exchange (ETDEWEB)

The wave equation of a spinless tachyon is studied in Schwarzschild space-time. In contrast to earlier approaches to the problem, it is shown that tachyonic static solutions satisfy a simple second-order linear differential equation regardless of the mass of the black hole and the mass parameter of the tachyon. Physical implication of the present approach is discussed. Using Langer modification of the WKB (Wentzel-Kramers-Brillouin) boundary condition an expression similar to the Bohr-Sommerfeld quantization condition is derived.

1981-02-01

477

Period lengthening in the V444 Cygni system and the mass loss by the Wolf--Rayet component  

Energy Technology Data Exchange (ETDEWEB)

New photoelectric photometry confirms that the period of V444 Cyg is lengthening at a rate P = 0.202 +- 0.018 sec/yr, implying a rate M = -(1.02 +- 0.20) x 10/sup -5/M/sub O//yr of mass loss by the WN5 component.

1984-07-01

478

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

479

Modelling the spatial and temporal evolution of winter glacier mass balance.  

Environmental Research Database

DescriptionChanges in glacier mass balance are critically influenced by the distribution of snow accumulation at the start of the melt season, but models of the winter season lag seriously behind those of the melt season. The overall aim is to test physically-based models of the spatial and temporal evolution of the winter snowpack at a temperate ice cap (Langjokull, Iceland), to assess how effectively and also how efficiently they capture variation in winter accumulation. A three-step modelling approach i [continued...

2004-01-31

480

Modelling of gravity changes in mining areas  

Energy Technology Data Exchange (ETDEWEB)

The numerical modelling of gravity changes resulting from the simultaneous effects of mass relocation and rock deformation is described. The method is supported by FEMMA (Finite Element Method for Multipurpose Applications) software, and has been used for modelling expected gravity changes in a large open pit coal mine in Poland. The results are in good agreement with conventional calculations of gravity changes for a simple geometry of relocated mass. 10 refs., 6 figs., 2 tabs.

1995-10-01

481

Mass-independent fractionation of oxygen isotopes during thermal decomposition of carbonates  

UK PubMed Central (United Kingdom)

Nearly all chemical processes fractionate 17O and 18O in a mass-dependent way relative to 16O, a major exception being the formation of ozone from diatomic oxygen in...Full Text Available

2002-08-20

482

Mass charge and angular momentum transfer in "1"0"6Cd + 255 MeV "5"4Fe collision studied by #gamma#-#gamma# coincidences  

International Nuclear Information System (INIS)

The distribution of mass, charge and angular momentum transfer among the products of 54-Fe (255 MeV) ions collisions with the 106 Cd target have been studied. The energy level schemes for 92-Mo, 60-Ni, 96-Ru and 56-Fe are presented. The production yields of different isotopes were also measured. 1 ref., 14 figs.

1991-12-01

483

Interactions between heavy mesons and Goldstone bosons from chiral dynamics  

Energy Technology Data Exchange (ETDEWEB)

We calculate the S-wave scattering lengths for charmed mesons scattering off Goldstone bosons and explore their quark mass dependence using the chiral perturbation theory up to next-to-leading order as well as a unitarized version of it. The quark mass dependence of all scattering lengths determined in a recent lattice calculation can be reproduced by the unitarized version. We also discuss signals of possible bound states in these observables. (orig.)

2009-05-15

484

Fragmentation of a single molten metal droplet penetrating sodium pool I copper droplet and the relationship with copper jet  

International Nuclear Information System (INIS)

The progression of hypothetical core disruptive accidents in metallic fuel fast breeder reactors is strongly affected by the fragmentation of molten metallic fuels due to the molten fuel-coolant interaction (FCI). As a basic study of FCI, the present paper focuses on the fragmentation of a single molten copper droplet with mass from 1 to 5 g, which penetrated a sodium pool at instantaneous constant interface temperatures (Ti) from 995 to 1,342degC. Intensive fragmentation of a single molten copper droplet was clearly observed even if Ti values are below the melting point (1,083degC) of copper besides the higher Ti range. The intensive fragmentation shows that the mass median diameters (Dm) of copper droplets with a fivefold difference in mass or the same mass have little difference, i.e., they are nearly the same. Under the lower Ti condition, the Dm data of droplet fragments of both the same and ...

2009-05-01

485

FORMATION PROCESS OF THE CIRCUMSTELLAR DISK: LONG-TERM SIMULATIONS IN THE MAIN ACCRETION PHASE OF STAR FORMATION  

International Nuclear Information System (INIS)

The formation and evolution of the circumstellar disk in unmagnetized molecular clouds is investigated using three-dimensional hydrodynamic simulations from the prestellar core until the end of the main accretion phase. In collapsing cloud cores, the first (adiabatic) core with a size of #approx#>3 AU forms prior to the formation of the protostar. At its formation, the first core has a thick disk-like structure and is mainly supported by the thermal pressure. After the protostar formation, it decreases the thickness gradually and becomes supported by the centrifugal force. We found that the first core is a precursor of the circumstellar disk with a size of >3 AU. This means that unmagnetized protoplanetary disk smaller than <3 AU does not exist. Reflecting the thermodynamics of the collapsing gas, at the protostar formation epoch, the first core (or the circumstellar disk) has a mass of #approx#0.005-0.1 M_s_u_n, while the protostar has a ...

2010-12-01

486

FORMATION EPOCHS, STAR FORMATION HISTORIES, AND SIZES OF MASSIVE EARLY-TYPE GALAXIES IN CLUSTER AND FIELD ENVIRONMENTS AT z = 1.2: INSIGHTS FROM THE REST-FRAME ULTRAVIOLET  

International Nuclear Information System (INIS)

We derive stellar masses, ages, and star formation histories (SFHs) of massive early-type galaxies in the z = 1.237 RDCS1252.9-2927 cluster and compare them with those measured in a similarly mass-selected sample of field contemporaries drawn from the Great Observatories Origin Deep Survey South Field. Robust estimates of these parameters are obtained by comparing a large grid of composite stellar population models with 8-9 band photometry in the rest-frame near-ultraviolet, optical, and IR, thus sampling the entire relevant domain of emission of the different stellar populations. Additionally, we present new, deep U-band photometry of both fields, giving access to the critical far-ultraviolet rest frame, in order to empirically constrain the dependence of the most recent star formation processes on the environment. We also analyze the morphological properties of both samples to examine the dependence of their scaling relations on their ...

2010-01-20

487

Experience with Aerosol Generation During Rotary Mode Core Sampling in the Hanford Single Shell Waste Tanks  

Energy Technology Data Exchange (ETDEWEB)

This document provides data on aerosol concentrations in tank headspaces, total mass of aerosols in the tank headspace, and mass of aerosols sent to the exhauster during rotary mode core sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based upon operational data and non-destructive assay.

2001-03-23

488

Experience with Aerosol Generation During Rotary Mode Core Sampling in the Hanford Single Shell Waste Tanks  

Energy Technology Data Exchange (ETDEWEB)

This document provides data on aerosol concentrations in tank head spaces, total mass of aerosols in the tank head space and mass of aerosols sent to the exhauster during Rotary Mode Core Sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based on operation data.

2000-01-24

489

Evolution of the luminosity function of quasar accretion disks  

International Nuclear Information System (INIS)

Using an accretion-disk model, accretion disk luminosities are calculated for a grid of black hole masses and accretion rates. It is shown that, as the black-hole mass increases with time, the monochromatic luminosity at a given frequency first increases and then decreases rapidly as this frequency is crossed by the Wien cutoff. The upper limit on the monochromatic luminosity, which is characteristic for a given epoch, constrains the evolution of quasar luminosities and determines the evolultion of the quasar luminosity function. 22 refs.

490

Does dynamic pricing make sense for mass market customers?  

Energy Technology Data Exchange (ETDEWEB)

The added incentive to modify electric use under hourly versus monthly market-based pricing is small for most mass market customers in Upstate New York. If the ultimate policy goal of demand-response programs is to reduce peak load, then promoting conservation measures under monthly market-based pricing holds more promise. (author)

2007-08-15

491

Development of a new secondary beam separator and a new gas-jet target at Kyushu University  

International Nuclear Information System (INIS)

In order to facilitate observations of low energy nuclear reactions, a new type recoil mass-separator together with a new gas-jet target system is being developed at the tandem accelerator facility in Kyushu University. The expected mass-resolving power of the separator is 220 for a solid angle of 10 msr and the practical thickness of the gas-jet target will exceed 0.1 atm#centre dot#cm for the light elements of H and He. (author).

1994-06-01

492

Density changes in amorphous Pd{sub 80}Si{sub 20} during low temperature ion irradiation  

Energy Technology Data Exchange (ETDEWEB)

Density changes in amorphous Pd{sub 80}Si{sub 20} during ion irradiation below 100K were detected by in situ HVEM measurements of the changes in specimen length as a function of ion fluence. A decrease in mass density as a function of the ion fluence was observed. The saturation value of the change in mass density was determined to be approximately -1.2%.

1994-11-01

493

Computed tomography of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Intrahepatic cholangiocarcinoma is an uncommon tumor as primary hepatic neoplasm. Five cases of cholangiocarcinoma, mass forming peripheral type, are reported about its CT findings. They were manifested as a poorly marginated low density mass with a irregular stellate area. In one case, a cut section of the gross specimen following surgery showed a central callagenous scar and vessels within the necrotic tumor. (author).

494

Chiral logarithms in quenched QCD  

Energy Technology Data Exchange (ETDEWEB)

The quenched chiral logarithms are examined on a 163x28 lattice with Iwasaki gauge action and overlap fermions. The pion decay constant fpi is used to set the lattice spacing, a = 0.200(3) fm. With pion mass as low as {approx}180 MeV, we see the quenched chiral logarithms clearly in mpi2/m and fP, the pseudoscalar decay constant. The authors analyze the data to determine how low the pion mass needs to be in order for the quenched one-loop chiral perturbation theory (chiPT) to apply. With the constrained curve-fitting method, they are able to extract the quenched chiral logarithmic parameter delta together with other low-energy parameters. Only for mpi<=300 MeV do we obtain a consistent and stable fit with a constant delta which they determine to be 0.24(3)(4) (at the chiral scale Lambdachi = 0.8 GeV). By comparing to the 123x28 lattice, they estimate the finite volume effect to be about 2.7% for the smallest pion ...

2004-08-01

495

Chiral logarithms in quenched QCD  

International Nuclear Information System (INIS)

The quenched chiral logarithms are examined on a 163x28 lattice with Iwasaki gauge action and overlap fermions. The pion decay constant fpi is used to set the lattice spacing, a = 0.200(3) fm. With pion mass as low as #approx#180 MeV, we see the quenched chiral logarithms clearly in mpi2/m and fP, the pseudoscalar decay constant. The authors analyze the data to determine how low the pion mass needs to be in order for the quenched one-loop chiral perturbation theory (chiPT) to apply. With the constrained curve-fitting method, they are able to extract the quenched chiral logarithmic parameter delta together with other low-energy parameters. Only for mpi<=300 MeV do we obtain a consistent and stable fit with a constant delta which they determine to be 0.24(3)(4) (at the chiral scale Lambdachi = 0.8 GeV). By comparing to the 123x28 lattice, they estimate the finite volume effect to be about 2.7% for the smallest pion mass. ...

2004-08-01

496

Cerebral sparganosis. Case report.  

Science.gov (United States)

The tapeworm Spirometra mansonoides infects man worldwide, particularly in Asian countries. Rarely, the central nervous system is involved; such a case is presented here. In the total of 12 reported cases, including the case described, the worm presented clinically as a mass suspicious for neoplasm or chronic abscess cavity. Surgical removal was invariably curative in each case. Although infrequent, the possibility of tapeworm infection should be entertained in the evaluation of intracranial masses in patients who have visited exotic locales. PMID:2191089

1990-07-01

497

CO sub 2 absorption/desorption in mixtures of methyldiethanolamine with monoethanolamine or diethanolamine  

Energy Technology Data Exchange (ETDEWEB)

The paper presents a compilation of data and model interpretation of CO{sub 2} with mixtures of amines. The data includes both absorption and desorption conditions in the 288-313K range. The combined mass transfer/equilibrium model can effectively represent CO{sub 2} mass transfer rates for the various mixtures under a wide range of conditions.

1991-01-01

498

Big bang nucleosynthesis and finite temperature field theory  

Energy Technology Data Exchange (ETDEWEB)

We consider electromagnetic corrections at finite temperature and their effect on the nucleosynthesis in the standard Big Bang scenario. This requires discussing the finite, temperature dependent correction to the neutron-proton mass difference as well as making use of a previous result on the temperature correction to the mass of the electron. We find that these corrections do not affect the conventional results of e.g. the helium abundance to any appreciable extent.

1982-11-11