Freezing phenomena in ice-water systems
Energy Technology Data Exchange (ETDEWEB)
The characteristics of solidification and melting are reviewed. The properties of water and ice and the phase diagram of water are discussed with special emphasis on ice density. A concise account of the freezing process and the Stefan problem is presented. To this end, the four stages of freezing are identified, supercooling, nucleation and the formation of dendritic ice, the growth of concentric rings of solid ice at 0{sup o}C and the final cooling of the solid ice are treated in some detail. The subject of bursting of pipes is given particular emphasis. Attention is drawn to a common misconception on pipe bursting and to misleading relationships for the computation of freezing time for ice blockage. Several current applications of melting and freezing systems are outlined. (author)
2002-09-01
International Nuclear Information System (INIS)
Manitoba Hydro's Ice Storm Management Program to reduce ice damage to overhead power lines in the voltage range of 8 kV to 115 kV is described. Overhead power lines are de-iced either by AC ice melting, which involves placing a three-phase short at a calculated point, or ice rolling, which is a process of mechanically stripping ice from conductors. Direct current heating and underground distribution systems are also accepted prevention measures. Advantages and disadvantages of each of these methods of de-icing are reviewed. Material for this paper has been extracted from a workshop manual prepared for the 1993 and 1998 Ice Storm Management workshops organized by Manitoba Hydro through the Canadian Electrical Association. 1 ref.
1999-03-29
Load calculation and system evaluation for electric vehicle climate control
Energy Technology Data Exchange (ETDEWEB)
This paper presents an analysis of the applicability of alternative systems for electric vehicle (EV) heating and air conditioning (HVAC). The paper consists of two parts. The first part is a cooling and heating load calculation for electric vehicles. The second part is an evaluation of several systems that can provide the desired cooling and heating in EVs. These systems are ranked according to their overall weight The overall weight is calculated by adding the system weight and the weight of the battery necessary to provide energy for system operation. The system with the minimum overall weight is considered to be the best, because minimum vehicle weight decreases the energy required for propulsion, and therefore increases the vehicle range. Three systems are considered as the best choices for EV ...
1994-09-12
Energy Technology Data Exchange (ETDEWEB)
TSS (thermal swing sublimation) method was studied which uses vaporization heat and sensible heat of LNG for solidification and separation of CO2 gas in waste gases of LNG-fired combined cycle power generation system. In experiment, the mixed gas composed of CO2, H2O and N2 was used for simulating waste gas of LNG-fired combined cycle power generation systems, and the growth behavior of ice and dry ice was studied for developing dry ice making technology under low-temperature condition. As the experimental result, the following were clarified: various crystal structures depending on cooling temperature, the effect of gas flow rate on peeling of surface precipitated solids, and solidification characteristics of H2O/CO2 mixed gas. The growth rate of precipitated solid film thickness decreased with an increase in gas flow rate, while increased with CO2 ...
1997-03-21
An analysis of selected atmospheric icing events on test cables
Energy Technology Data Exchange (ETDEWEB)
In cold countries, the design of transmission lines and communication networks requires the knowledge of ice loads on conductors. Atmospheric icing is a stochastic phenomenon and therefore probabilistic design is used more and more for structure icing analysis. For strength and reliability assessments, a data base on atmospheric icing is needed to characterize the distributions of ice load and corresponding meteorological parameters. A test site where icing is frequent is used to obtain field data on atmospheric icing. This test site is located on the Mt. Valin, near Chicoutimi, Quebec, Canada. The experimental installation is mainly composed of various instrumented but non-energized test cables, meteorological instruments, a data acquisition system, and a video recorder. Several types of icing ...
1996-12-01
Energy Technology Data Exchange (ETDEWEB)
An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating cost compared with ...
1996-02-01
Energy Technology Data Exchange (ETDEWEB)
Substantial thermal performance improvement in ice-on-tube cold thermal energy storage systems (TES) is possible by making use of porous copper mesh as a Heat Conducting Enhancement Device (HCED). HCEDs are inexpensive heat transfer augmentation devices that can result in faster rate of ice growth and larger final steady state ice build volume by reducing the controlling thermal conduction resistance of the ice layer. This improves the competitiveness of external ice-on-tube systems as compared to other TES systems, such as dynamic ice harvesters and static internal melt systems. In this study the amount of ice growth enhancement is predicted theoretically, by performing simplified 1-D calculations, and is then validated in the laboratory through carefully ...
2006-09-15
Energy Technology Data Exchange (ETDEWEB)
An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.
1994-07-01
UK PubMed Central (United Kingdom)
BackgroundRadiofrequency ablation (RFA) of tumors by means of internally cooled electrodes (ICE) combined with interstitial infusion of saline may improve clinical results. To date,...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
The reinforced concrete artificial iced course, constructed first in Japan as a bobsleigh and luge track for the Nagano Olympic Games, has a total extension of 1,700 m and an altitude difference of 113 m. It contains 15 curves and 2 up-grades and is divided into 43 blocks with spans ranging from 20 m to 80 m, all of which consist of lightwall RC members supported by pile foundations. The surface is cooled to -15 centigrade by the cooling pipes embedded in concrete and is iced by spraying water, and iced surface is shaved to make a course. Since the course scarcely has same profiles, the finished wall thickness is secured by fixing wire gauzes on the required positions without using shutterings. As there is not existed concrete satisfying all the required quality, two kinds of concrete were selected for filling in the arrangement of reinforcement and pipes and for surface finishing. ...
1996-03-10
Energy Technology Data Exchange (ETDEWEB)
The generation of thermal energy is the great importance for the agribusiness of dairy industry to conservation the quality of milk, taking into account that the electricity is the main source currently used for the thermal energy input. The small agribusiness dairy industry currently practiced in Brazil faces several problems related to the cost of electricity and the distance of rural properties of networks of power. In the current scenario of Brazilian dairy production, there is need for the generation of cold for the milk cooling, and also the heat for the production of hot water around 50 deg C to 60 deg C and also for cleaning of equipment used for milk production and processing. The main objective of this study is the modeling and simulation of integrated recovery process of solid waste, effluents and bioconversion. The specific project objectives are: comparison study of options and technological routes of low cost material for power generation using ...
2008-07-01
A space crystal diffraction telescope for the energy range of nuclear transitions
Energy Technology Data Exchange (ETDEWEB)
This paper contains literature from American Power Conference Air Toxics Being Measured Accurately, Controlled Effectively NO{sub x} and SO{sub 2} Emissions Reduced; Surface Condensers Improve Heat Rate; Usable Fuel from Municipal Solid Waste; Cofiring Technology Reduces Gas Turbine Emissions; Trainable, Rugged Microsensor Identifies of Gases; High-Tc Superconductors Fabricated; High-Temperature Superconducting Current Leads; Vitrification of Low-Level Radioactive and Mixed Wastes; Characterization, Demolition, and Disposal of Contaminated Structures; On-Line Plant Diagnostics and Management; Sulfide Ceramic Materials for Improved Batteries; Flywheel Provides Efficient Energy Storage; Battery Systems for Electric Vehicles; Polymer-Electrolyte Fuel Cells for Transportation; Solid-Oxide Fuel Cells for Transportation; Surface Acoustic Wave Sensor Monitors Emissions in Real-Time; Advance Alternative-Fueled Automotive Technologies; Thermal & Mechanical Process; ...
1995-04-01
Evaluation of Two Microclimate Cooling Air Vests on a Heated ...
... If the MCAV is used in conjunction with a cooling system designed for the CVC air vest, the wearer would receive more cooling due entirely to the ...
1992-12-01
Impingement-Film Heat Transfer Investigation.
... Abstract : This report covers the investigation of an impingement-film cooling system designed to cool the exhaust ducts of turboshaft engines ...
1973-12-01
Battery Thermal Management System Design Modeling
Energy Technology Data Exchange (ETDEWEB)
Looks at the impact of cooling strategies with air and both direct and indirect liquid cooling for battery thermal management.
2006-11-01
Energy Technology Data Exchange (ETDEWEB)
A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water. 5 figs.
1980-01-22
DESIGN OF A CONVECTIVE COOLING SYSTEM FOR A MACH 6 - NASA ...
Figure 23 presented detailed layout of the cooling system designed for the Mach 6 hypersonic- transport. The distribution system consisted of thin-wall ...
Propagation Effects Handbook for Satellite Systems - DESCANSO - NASA
time as well, due to the complex patterns of air movement taking place within cumulus clouds. ...... cumulative distribution of XPD, for rain and ice-particle induced ...... CCIR (1986f), Attenuation by Hydrometeors, In Particular ...
Energy Technology Data Exchange (ETDEWEB)
Inverse and direct methods have been used to analyze a large number of borehole temperature logs in order to infer past climatic changes. Results indicate a warming of 1-2[degree]C in eastern and central Canada during the past 150 years. A period of cooling between 500 and 200 years before present, corresponding to the time of the Little Ice Age, has also been identified in the same areas. A regional ground temperature history is estimated for eastern and central Canada from the simultaneous inversion of several temperature logs. The inferred temperature changes appear correlated with the concentration of atmospheric carbon dioxide as reported from a Greenland ice core, and agree with existing meteorological and dendrochronological records for the area.
1992-12-01
British Library Electronic Table of Contents (United Kingdom)
During sporting events, injured athletes often return to competition after icing because of the reduction in pain. Although some controversy exists, several studies suggest that cryotherapy causes a decrease in muscle activity, which may lead to a higher risk of injury upon return to play. The purpose of this study was to investigate the effect of a 20-min knee joint cryotherapy application on the electromyographic activity of leg muscles during a single-leg drop jump in twenty healthy subjects, randomly assigned to an experimental and a control group. After the pre-tests, a crushed-ice bag was applied to the knee joint of the experimental group subjects for 20min, while the control group subjects rested for 20min. All subjects were retested immediately after this period and retested again...
2010-01-01
Development of superconducting cryo-electron microscope and its applications
International Nuclear Information System (INIS)
Recently, a superconducting cryo-electron microscope in which specimens are cooled to the liquid helium temperature (4.2 K) has been developed. The main components and functional features of this new microscope are reported together with application data on polyethylene, poly (4-methyl-1-pentene), valonia cellulose, rock salt, ice crystallites and ceramic superconductor. The resistance to electron radiation damage, of beam-sensitive specimens including polymers has been increased more than ten times. Thus, the microscope has made it possible to take high resolution images and to analyze the crystal-structure of micro-areas. (orig.).
1988-01-01
British Library Electronic Table of Contents (United Kingdom)
This work is focused on effect of various cooling strategies on surface roughness and tool wear during computer aided milling of soft workpiece materials. These milling operations were selected as dry milling, cool air cooling milling and fluid cooling milling. A cool air cooling system was designed and produced to cool end milling tools. Cool air was produced by a vortex tube. Annealed AISI 1050 was used as the workpiece material and cutting tool material was selected as HSS-Co8 DIN 844/BN. Optimal cutting parameters were selected according to workpiece hardness from reference catalog and kept for all tests. Tool wear and surface quality were measured for three different cooling types changing from ten minute machining time to thirty minute machining time. As a result, the ...
2009-01-01
Space Food and Nutrition pdf - Space Shuttle Experience - NASA
Yellow cake with chocolate frosting. Dairy: Ice cream, chocolate. Ice cream, strawberry. Ice cream, vanilla. Yogurt, frozen ...
Energy Technology Data Exchange (ETDEWEB)
A cost study is described which compared the economics of four dry/wet cooling systems to use at the existing Raft River Geothermal Plant. The results apply only at this site and should not be generalized without due consideration of the complete geothermal cycle. These systems are: the Binary Cooling Tower, evaporative condenser, Combin-aire, and a metal fin-tube dry cooling tower with deluge augmentation. The systems were evaluated using cooled, treated geothermal fluid instead of ground or surface water in the cooling loops. All comparisons were performed on the basis of a common plant site - the Raft River 5 MWe geothermal plant in Idaho. The Binary Cooling Tower and the Combin-aire cooling system were designed assuming the use of the isobutane/water ...
1982-07-01
Energy Technology Data Exchange (ETDEWEB)
In this work theoretical investigations are carried out for cooling systems, which are used in fuel cell vehicles. This work focuses mainly on the capability of increasing the heat rejection rate by using new alternative cooling systems and by improving the conventional cooling system. Fuel cell vehicles have a higher demand of heat rejection to the ambient than comparable vehicles with combustion engine. The performance of conventional liquid cooling systems, especially at high loads and high ambient temperatures, is often not sufficient anymore. Hence, cooling systems with improved performance are necessary for fuel cell vehicles. The investigations in this work are based on DaimlerChrysler's ''A-Class'' having a PEM-Fuel Cell ...
2008-04-01
British Library Electronic Table of Contents (United Kingdom)
Ways of improving the water chemistry used in the turbine generator stator?s cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.
2011-01-01
Cooling device for impurity removal device in thermonuclear devices
International Nuclear Information System (INIS)
Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the ...
1983-08-26
Integrated Reconfigurable Intelligent Systems (IRIS) for ...
... They comprise of a power model for the representation of the electric system, a fluid model that represents the cooling fluid flow, three layers of ...
2009-10-31
HANARO cooling features: design and experience
International Nuclear Information System (INIS)
In order to achieve the safe core cooling during normal operation and upset conditions, HANARO adopted an upward forced convection cooling system with dual containment arrangements instead of the forced downward flow system popularly used in the majority of forced convection cooling research reactors. This kind of upward flow system was selected by comparing the relative merits of upward and downward flow systems from various points of view such as safety, performance, maintenance. However, several operational matters which were not regarded as serious at design come out during operation. In this paper are presented the design and operational experiences on the unique cooling features of HANARO. (author)
1999-08-01
Energy Technology Data Exchange (ETDEWEB)
For most cells there exists an optimum cooling rate. Both supraoptimal rates and suboptimal rates can be very damaging. The optimal rate varies enormously from less than or equal to 1/sup 0/C/min for mammalian preimplantation embryos to greater than or equal to 800/sup 0/C/min for the human red cell. Death at supraoptimal rates is the result of the formation of intracellular ice and its recrystallization during warming. Intracellular ice occurs when cells are cooled too rapidly to allow them to equilibrate by the osmotic withdrawal of intracellular water. The definition of too rapid depends chiefly on the size of the cell and its permeability to water. Death at suboptimal rates is a consequence of the major alterations in aqueous solutions produced by ice formation. The chief effects are a major reduction in the fraction of the solution remaining unfrozen at a given temperature and ...
1980-01-01
A theoretical evaluation of solar-powered desiccant cooling in the United Kingdom
Energy Technology Data Exchange (ETDEWEB)
Desiccant cooling is a potentially environmentally friendly technology that can be used to condition the internal environment of buildings. Unlike conventional air conditioning systems, which rely on electrical energy to drive the cooling cycle, desiccant cooling is a heat-driven cycle. This paper follows on from an initial study by the authors, and uses real meteorological data to evaluate the potential in the United Kingdom of using solar energy to drive the desiccant cooling cycle. Through the use of parametric studies, the paper investigates the energy consumption and costs associated with desiccant cooling. (author)
1999-07-01
The Stefan Problem Revisited: A Continuum Model of Frost Heave
The classical Stefan problem describes the motion of a solidification front through a uniform half-space in response to a step change in temperature on its boundary. The predictions of such a model can be applied quite accurately to the freezing of water in a porous medium so long as the pore geometry remains unaltered by the passing solidification front. It is observed, however, that in fine-grained porous media, ice has a tendency to form in segregated horizontal bands, known as ice lenses, that disrupt the regular pattern of heat flow through their enhanced consumption of latent heat. This process, known as frost heave, causes significant ground deformation in regions subject to prolonged freezing, and is one of the most important weathering processes in polar and alpine regions. Recent improvements to our understanding of the mechanics of ice lens nucleation and growth are applied here to predict the conditions and ...
2005-12-01
Wind tunnel test on a straight wing vertical-axis wind turbine with attachment on blade surface
Energy Technology Data Exchange (ETDEWEB)
There is a renewed interest in straight wing vertical axis wind turbines (SW-VAWT) which are usually installed on the roofs of high buildings in cities, urban areas and high mountain areas for independent electric power supply. SW-VAWTs have the advantages of simple design and low cost, as well as wind direction independence compared to the horizontal system. However, when SW-VAWTs are installed in cold regions, ice, snow and other attachments can affect its performance. In this study, clay was attached to the leading edge of the blade surface to determine how the performance of SW-VAWTs are affected by the mechanism of icing. Wind tunnel tests were used to study the rotational performance and power performance of the turbine blades. Icing prevention was also investigated. The attachment of clay on the leading edge of blade surface made the rotational performance of the SW-VAWT worse. The attachment of ...
2008-07-01
Ocean teleconnections between Antarctica and the Equatorial Pacific and Atlantic.
Environmental Research Database
Objectives(i) Investigate the correlation between Antarctic sea-ice and equatorial sea-surface temperature anomalies in a realistically forced ocean model simulation of the last 50 years. (ii) Determine whether and how the enormous seasonal change in distribution of sea-ice modifies the seasonal cycle at the Equator. (iii) Determine the detailed pathways of wave propagation both in a historically-forced simulation and in response to realistic perturbations. (iv) Quantify the amplitude of the response i [continued...]DescriptionIt is well known that the equatorial ocean-atmosphere system plays a key role in global climate events such as the El Nino-Southern Oscillation (ENSO) phenomenon. There is now compelling evidence that changes in the Antarctic can strongly and quickly affect the equatorial ocean and the ENSO cycle. Observations demonstrate statistically significant correlations (teleconnections) between the Antarctic ...
2009-01-31
Energy Technology Data Exchange (ETDEWEB)
A new type of passive cooling system has been invented (Forsberg 1993): the Temperature-Initiated Passive Cooling System (TIPACS). The characteristics of the TIPACS potentially match requirements for an improved reactor-cavity-cooling system (RCCS) for the modular high-temperature gas-cooled reactor (MHTGR). This report is an initial evaluation of the TIPACS for the MHTGR with a Rankines (steam) power conversion cycle. Limited evaluations were made of applying the TIPACS to MHTGRs with reactor pressure vessel temperatures up to 450 C. These temperatures may occur in designs of Brayton cycle (gas turbine) and process heat MHTGRs. The report is structured as follows. Section 2 describes the containment cooling issues associated with the MHTGR and the requirements for such a cooling ...
1994-04-01
Closed loop air cooling system for combustion turbines
Energy Technology Data Exchange (ETDEWEB)
Convective cooling of turbine hot parts using a closed loop system is disclosed. Preferably, the present invention is applied to cooling the hot parts of combustion turbine power plants, and the cooling provided permits an increase in the inlet temperature and the concomitant benefits of increased efficiency and output. In preferred embodiments, methods and apparatus are disclosed wherein air is removed from the combustion turbine compressor and delivered to passages internal to one or more of a combustor and turbine hot parts. The air cools the combustor and turbine hot parts via convection and heat is transferred through the surfaces of the combustor and turbine hot parts.
1998-01-01
Phytoplankton primary production in a eutrophic cooling water pond
Energy Technology Data Exchange (ETDEWEB)
The effect of longer ice-free periods on the seasonal variation and total annual values of phytoplankton primary production was considered along with the efficiency and productivity of the phytoplankton communities at different water temperatures by constant light. The studied pond, Vasikkalampi, is located in the town Jvyaskyla in central Finland. The pond is slightly eutrophic and its water is used for cooling purposes by a 35 MW thermal powerplant. The cooling water is taken in the middle of the pond and it returns as heated effluent to the northern part, near the surface, about 100 m from the intake pipe. This circulation and warming of the water keeps the pond open throughout the year except during the coldest weeks in the winter when some parts freeze over. The increase of the water temperature was not sufficient to be optimal for photosynthesis in the spring. The phytoplankton biomass starts to increase early in the ...
1984-01-01
International Nuclear Information System (INIS)
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.
Observation of Spontaneous Brillouin Cooling
While radiation-pressure cooling is well known, the Brillouin scattering of light from sound is considered an acousto-optical amplification-only process. It was suggested that cooling could be possible in multi-resonance Brillouin systems when phonons experience lower damping than light. However, this regime was not accessible in traditional Brillouin systems since backscattering enforces high acoustical frequencies associated with high mechanical damping. Recently, forward Brillouin scattering in microcavities has allowed access to low-frequency acoustical modes where mechanical dissipation is lower than optical dissipation, in accordance with the requirements for cooling. Here we experimentally demonstrate cooling via such a forward Brillouin process in a microresonator. We show two regimes of operation for the Brillouin process: acoustical amplification as is ...
2011-01-01
FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...
was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...
MASER"'\\ - NASA Technical Report Server (NTRS)
cooling system designed to reject waste heat producedwithin the alternatorand. To other equipment operatingat much lower tempera- ...
Overview of Cooling Water System for the KSTAR 1st Plasma Experiment
International Nuclear Information System (INIS)
The KSTAR cooling water system (CWS) consists of a primary cooling water system (PCWS), a secondary cooling water system (SCWS), and a de-mineralizing and de-ionized water system (DIWS). The PCWS cooling loops have been made for the poloidal field (PF) and toroidal field (TF) magnet power supplies (MPS), vacuum vessel (VV), electron cyclotron heating (ECH), ion cyclotron heating (ICRH), vacuum pumps, diagnostics, helium facility, etc. The CWS had been done individual commissioning of each system to confirm the design specifications by the end of 2006 and had gradually begun operation for the KSTAR ancillary devices by March 2008
2009-05-01
Behavior of ice covers subjected to large daily flow and level fluctuations
Energy Technology Data Exchange (ETDEWEB)
The stability of a solid ice cover subjected to rapidly varying water levels and discharge was investigated. The support from the bank limits the stress in the ice cover and consequently bank contact must be maintained to ensure ice cover stability. An analysis was required of the stability of ice hinges, a flexible connection between a solid ice cover and the riverbank. Phase II and phase III of the research involved a field study of the Peace River, investigating the evolution of ice hinges with water level variation, from initial ice cover cracking parallel to the banks, to a fully developed hinge. A test program of midwinter discharge variations was undertaken to gather specific data and measurements of ice hinge link length, ice thickness, hinge joint behavior, riverbank geometry, and response ...
1984-11-01
Study on adsorption of methanol onto carbon based adsorbents
Energy Technology Data Exchange (ETDEWEB)
This paper presents the isothermal characteristics of methanol onto two specimens of activated carbons namely Maxsorb III and Tsurumi activated charcoal. Dubinin Raduskevich (D-R) equation is used to correlate the adsorption isotherms and to form the pressure-temperature-concentration diagram for both of the assorted pairs. Experimental results show that the maximum adsorption capacity of Maxsorb III/methanol pair is 1.76 times that of activated charcoal/methanol pair. Employing a time-independent mathematical model, the performance of adsorption cooling cycle using Maxsorb III/methanol and activated charcoal/methanol pairs has been studied and compared with that of three other types of carbon based adsorbent/methanol pairs. Theoretical calculations show the superiority of Maxsorb III/methanol pair for both of air-conditioning and ice-making applications. (author)
2009-11-15
Climatic change and river ice breakup
Energy Technology Data Exchange (ETDEWEB)
An overview of climatic factors and impact relative to river ice engineering and science is presented. An explanation of the fundamentals of climatic change is followed by a review of direct and indirect climatic influences that govern river ice breakup and related trends. Known responses of river ice to climatic change and potential future changes to ice breakup processes are described along with the probable ecological and socio-economic consequences of these changes. Changes in engineering approaches to accommodate the present ice regime and predicted changes in climatic variables that affect river ice processes and reduce the vulnerability of infrastructure and ecosystems to climatic change are examined. Future research on the links between river ice and stream ecology is suggested to identify ecological concerns that may result from ...
2003-07-01
User's guide for the BNW-III optimization code for modular dry/wet-cooled power plants
Energy Technology Data Exchange (ETDEWEB)
This user's guide describes BNW-III, a computer code developed by the Pacific Northwest Laboratory (PNL) as part of the Dry Cooling Enhancement Program sponsored by the US Department of Energy (DOE). The BNW-III code models a modular dry/wet cooling system for a nuclear or fossil fuel power plant. The purpose of this guide is to give the code user a brief description of what the BNW-III code is and how to use it. It describes the cooling system being modeled and the various models used. A detailed description of code input and code output is also included. The BNW-III code was developed to analyze a specific cooling system layout. However, there is a large degree of freedom in the type of cooling modules that can be selected and in the performance of those modules. The costs of the modules are input to the code, ...
1984-09-01
A Single Laser System for Ground State Cooling of 25-Mg+
We present a single solid-state laser system to cool, coherently manipulate and detect $^{25}$Mg$^+$ ions. Coherent manipulation is accomplished by coupling two hyperfine ground state levels using a pair of far-detuned Raman laser beams. Resonant light for Doppler cooling and detection is derived from the same laser source by means of an electro-optic modulator, generating a sideband which is resonant with the atomic transition. We demonstrate ground-state cooling of one of the vibrational modes of the ion in the trap using resolved-sideband cooling. The cooling performance is studied and discussed by observing the temporal evolution of Raman-stimulated sideband transitions. The setup is a major simplification over existing state-of-the-art systems, typically involving up to three separate laser sources.
2010-01-01
Doublet III limiter/armor update
Energy Technology Data Exchange (ETDEWEB)
The Doublet III device is operating with an extensive system of plasma limiters and wall protective armor. Operations with up to 8MW of neutral beam power and 1.5MA plasma current are planned. Design and operational performance of the following systems are discussed: 1. Water-cooled graphite moveable limiter. 2. Water-cooled graphite fixed limiter and neutral beam wall armor. 3. Radiatively cooled Inconel divertor plates.
1983-12-01
Desiccant cooling: parametric energy study
Energy Technology Data Exchange (ETDEWEB)
Desiccants have been used in many applications to provide dehumidification. This paper describes an application of desiccants which provide both dehumidification and sensible cooling, with little or no use of conventional vapour-compression refrigeration plant. Through a parametric study, the energy consumption and costs of a desiccant cooling system are compared with those of a conventional vapour-compression refrigeration-based air-conditioning system. (author)
1998-12-31
Full-scale model of cooling and heating system for JT-60 vacuum vessel
A full-scale model of a rigid sectorial ring and a set of bellows which was covered with a temperature control layer and a coolant supply equipment was constructed to verify the adequacy of the heating and cooling system designed for JT-60. To cool and heat it effectively and to decrease the temperature differences among the various parts in the vacuum vessel, heater units and cooling pipes were located on the surface of the ring. The temperature control layer is to heat the vessel to 500/degree/sub //C within 70 hours and to maintain it at the temperature for 48 hours for simulating the state of bakeout. Subsequently the vessel is cooled down within about the same time as in heating. Prior to the series of tests, numerical analyses were performed to predict the cooling and heating efficiencies on the model and to examine the method of the temperature ...
1981-01-01
Control of cooling during spray forming of bearing steel billets
Energy Technology Data Exchange (ETDEWEB)
In an effort to minimize the distortion of bearing steel rings during the production process, 100Cr6 steel billets are spray formed with a unique cooling control system to control the cooling and solidification behavior of the deposits. Effects of heating around the deposits, gas cooling at the substrate bottom and the gas flow over the deposits are investigated both by numerical simulation and experiment. Porosity profiles and microstructures of spray formed bearing steel are examined and evaluated. The investigation results show that the thermal boundary conditions of the deposits play important roles on the cooling and solidification behavior of the deposits, especially at the deposit periphery. Porosity in the 100Cr6 bearing steel deposit can be reduced significantly with the special cooling control system.
2004-10-10
The Goddard Library - Goddard Projects Directory - NASA
Oct 2, 2007 ... Other payloads included the Orbiter Experiments Autonomous Supporting Instrumentation System-1 (OASIS-1), a cooling system designed for ...
RESEARCH MEMORANDUM - NASA Technical Report Server (NTRS)
lytical Comparison of Turbine-Blade Cooling System Designed for a. TurboJet Engine Operat- at Supersonic Speed and Altitude. I1 -. Air-C~Oling Systems. ...
Energy Technology Data Exchange (ETDEWEB)
Ice jamming, known to cause high water levels at even moderate river flows, is described as both the main and least understood source of ice-related bridge damages. This paper describes a joint study by the New Brunswick Department of Transportation, the Department of the Environment, local governments, and the National Water Research Institute, designed to address problems associated with the interaction of ice jams and bridges. The study consists of collecting information at each of four sites in New Brunswick including: historical data on ice jam locations, causes, and water levels; channel bathymetry, width and slope within each study centred at the respective bridge; and documentation of ice conditions throughout the ice season, including measurement of ice cover thickness, observation of breakup mechanisms, times, causes, ...
2000-12-01
UK PubMed Central (United Kingdom)
Glacier ice worms, Mesenchytraeus solifugus and related species, are the largest glacially obligate metazoans. As one component of cold temperature adaptation, ice worms maintain atypically...Full Text Available
User's manual for the BNW-I optimization code for dry-cooled power plants. [MFCIRI Code
This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)
1977-01-01
British Library Electronic Table of Contents (United Kingdom)
In order to provide pigs a comfortable sleeping area in hot weather, a floor cooling system was designed and applied to production buildings. Experiments were conducted to compare the floor temperatures and to observe the lying behaviour of pigs in the sleeping area of the buildings with and without floor cooling system. The results showed that, without the floor cooling system, the floor temperature was nearly the same as the air temperature in the open pig house. With the floor cooling system, the floor temperature of the sleeping area was controlled at 22-26degreeC, even though the air temperature was as high as 34degreeC, which improved the comfort of the pigs in the sleeping area. The pig lying behaviour was greatly affected by the floor temperature. More than 85% of the pigs were lyi...
2006-01-01
Tilt-a-Worlds: Effects of High Rates of Obliquity Change on the Habitability of Extrasolar Planets
We explore the impact of obliquity variations on planetary habitability in hypothetical systems with high mutual inclination. For the hypothetical systems, we restrict our exploration to systems consisting of a solar-mass star, an Earth-mass planet at 1 AU, and 1 or 2 giant planets. We verify that these systems are stable for 108 years with N-body simulations. We then calculate the obliquity variations induced by the orbital architecture on the Earth-mass planets. We find that in some cases the spin axes can rotate through 360 degrees in as little as 10,000 years (John is that right? Can you look through the systems and find the most extreme case of obliquity variation?) Next, we run energy balance models (EBM) on the terrestrial planets to assess surface temperature and ice coverage on the planets' oceans. Finally, we explore differences in the outer edge of ...
2011-01-01
Calculation of ice accumulation rates in Antarctica over the last glacial cycle.
Environmental Research Database
DescriptionRates of ice accumulation in Antarctica are not known well, yet they are fundamental to assessing the ice sheet mass balance. Past accumulation rates are less well defined. We are in a unique position to provide detailed accounts of accumulation in Antarctica. We will measure isochronous internal layering across the ice sheet, which can be readily identified in radar data that we hold. Internal layers will be traced to ice-cores (allowing dating) and across wide regions of the ice sheets. A nume [continued...
2006-01-08
Energy Technology Data Exchange (ETDEWEB)
This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
1998-12-31
Liquid level control system of fast reactor secondary cooling system
International Nuclear Information System (INIS)
Object: To minimize the range of the liquid level variation of the cooling system and reduce the time required for the liquid level control by sealing the gas of a cover gas respiration system which acts upon an evaporator and pump overflow column. Structure: In liquid level control by the cover gas pressure of a high-speed reactor secondary cooling system, upon occurrence of a sudden change in the rate of flow of the recirculated liquid, automatic check valves provided in an evaporator and pump overflow column cover gas respiration system are completely or substantially closed, while at the same time the recirculation cooling medium is sucked up and an automatic check valve provided in the overflow system is closed. (Kamimura, M.).
Strategy for forecasting ice breakup and jamming: Saint John River, New Brunswick
Energy Technology Data Exchange (ETDEWEB)
Development of a strategy for forecasting river ice breakup and jamming on the Saint John River in New Brunswick was described. Methods used to identify ice jam-prone areas by simple temperature-based methods to fairly complex computer models using site specific data, were summarized. Recent technological advances in developing forecasts, including the NWRI probe for remotely measuring ice jam thickness, the RIVJAM model for determining stages upstream of an ice jam, and computational procedures for estimating the thrust exerted by ice jams against bridges, were also reviewed. Criteria and recommendations for river ice breakup and ice jamming for the Saint John River were provided. (Abstract only).
1995-12-31
IV&V Cost Estimation-A Joint NASA & Navy
Possible ICE Tools Relationship. within a Business Model ... Established a Joint IV&V Cost Estimating (ICE) Team comprised of Personnel from NASA, ...
Cook Inlet and Kenai Peninsula, Alaska ESI: ICE (Ice Extent Lines)
... layer, part of the larger Cook Inlet and Kenai Peninsula ESI database, for additional hydrologic information. This ... ...
Nomographs for H[sub 2]O-LiBr absorption-panel cooling systems
Energy Technology Data Exchange (ETDEWEB)
Panel cooling of buildings offers energy savings over conventional space-cooling systems. We present a procedure for calculating the performance of H[sub 2]O-LiBr absorption-panel cooling systems, in which the evaporator is the panel itself. Nomographs have been developed for this approach. Under the conditions examined, the H[sub 2]O-LiBr absorption unit operates with a theoretical performance coefficient of about 90% and with a practically constant specific cooling capacity of 2394 kJ/kg H[sub 2]O. For common values of the parameters involved, the panel cooling power varies from 25 to 175 W/m[sup 2] and the cooling water mass-flow through the panel is 40-260 g/m[sup 2]h. The thermal power needed to drive the system varies from 27 to 200 W/m[sup 2] and the associated temperatures from 70 to 100[sup ...
1992-11-01
Behavior of ice covers subjected to large daily flow and level fluctuations
Energy Technology Data Exchange (ETDEWEB)
The stability of a solid ice cover subjected to rapidly varying water levels and discharge was investigated. The support from the bank limits the stress in the ice cover and consequently bank contact must be maintained to ensure ice cover stability. An analysis was required of the stability of ice hinges, a flexible connection between a solid ice cover and the riverbank. Phase II and phase III of the research involved a field study of the Peace River, investigating the evolution of ice hinges with water level variation, from initial ice cover cracking parallel to the banks, to a fully developed hinge. A test program of midwinter discharge variations was undertaken to gather specific data and measurements of ice hinge link length, ice thickness, hinge joint behavior, riverbank geometry, and response ...
1984-11-01
Results are reported from dye tests of the dispersion of the vapor plume from the natural draft cooling tower of a fossil-fuel power plant located in the coastal region of Maryland.
1977-12-01
Terra Nova FPSO on the Grand Banks of Canada
Energy Technology Data Exchange (ETDEWEB)
An increased use of floating production facilities for offshore oil production in the past fifteen years was due in part to advances in technology, the opening of new frontiers and the increased emphasis on value driven development. Throughout the world, a total of 121 floating production systems were in operation in February 2001, and orders had been placed for an additional 27. Located near the nose of the Grand Banks, approximately 350 kilometres east-southeast of St. John's, Newfoundland is the Terra Nova development. Twelve years elapsed between the discovery of the field in 1984 and the granting of the approval for development in 1996. The decision was made to use a floating production system as the Terra Nova was not considered robust enough to support a gravity base, ice resistant structure development concept, especially considering that it came on the heels of the Hibernia development. The first Floating ...
2001-07-01
Energy Technology Data Exchange (ETDEWEB)
Glacier fluctuations exclusively due to internal variations in the climate system are simulated using downscaled integrations of the ECHAM4/OPYC coupled general circulation model (GCM). A process-based modeling approach using a mass balance model of intermediate complexity and a dynamic ice flow model considering simple shearing flow and sliding are applied. Multi-millennia records of glacier length fluctuations for Nigardsbreen (Norway) and Rhonegletscher (Switzerland) are simulated using auto-regressive processes determined by statistically downscaled GCM experiments. Return periods and probabilities of specific glacier length changes using GCM integrations excluding external forcings such as solar irradiation changes, volcanic or anthropogenic effects are analyzed and compared to historical glacier length records. Preindustrial fluctuations of the glaciers as far as observed or reconstructed, including their advance during the ...
2001-08-01
Development of radial-flow type internally oil-cooled oil-filled cable
Energy Technology Data Exchange (ETDEWEB)
A radial-flow type internally oil-cooled oil-filled cable has been developed. This system is characterized in that the oil flows radially through the paper insulation. The thermal resistance of the insulation is equivalently decreased by the radial-flow. The decreased thermal resistance as well as the cooling effect of the oil flow in the central oil duct and the outer oil duct under an aluminum sheath increase the current capacity. A calculation method of cooling characteristics is introduced. The stability of the cable and accessories was confirmed through initial electrical tests and a long-term field test.
1988-01-01
International Nuclear Information System (INIS)
The General Electric Test Reactor emergency cooling system performance was tested by intentionally scramming the reactor and then terminating the power to the primary pump. Certain transient thermal-hydraulic data were obtained preceding and during the established natural convection cooling loop composed of the upward flow through the core and the downward flow through the pool. An analysis was performed to permit the data to be extrapolated to obtain distributed fuel element flow rates and bulk temperature rises during the established cooling loop. The earliest time for the quasi-steady natural cooling loop to develop is about 2.5 min following scram. The cladding hot-spot temperature does not exceed the local saturation temperature after quasi-steady flow is established. Data are presented to assist in the modeling of the GETR natural convection loop. Semi-empirical relationships ...
APOD: 2004 September 4 - Neutron Mars
ice could be responsible for the formation of martian gullies. Tomorrow's picture: whirlpool ...
2011-10-07
2009 Community Sequencing Program: Life Under Ice
...carbon dioxide in the atmosphere contributes to global warming anything that could ...
Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides
Energy Technology Data Exchange (ETDEWEB)
The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)
2004-07-01
Performance analysis on a hybrid air-conditioning system of a green building
Energy Technology Data Exchange (ETDEWEB)
This paper presents the performance analysis on a hybrid air-conditioning system according to the hybrid building energy system of the green building demonstration project in Shanghai, in which a 150 m{sup 2} solar collector is used to power two 10 kW adsorption chillers, a vapor compression heat pump is used to cool air in the evaporating end while the condensing heating at about 80{sup o}C is fully used to regenerate a liquid desiccant dehumidification system. In the hybrid system, the sensible cooling to the air is treated mainly by solar adsorption cooling and vapor compression cooling, whereas the latent heat is treated by the liquid desiccant dehumidification system with regeneration from the condensing heat of the heat pump. The results show that the performance of this ...
2006-05-15
Collisions with ice-volatile objects: Geological implications
International Nuclear Information System (INIS)
The collision of the Earth with extra-terrestrial ice-volatile bodies is proposed as a mechanism to produce rapid changes in the geologic record. These bodies would be analogs of the ice satellites found for the Jovian planets and suspected for comets and certain low density bodies in the Asteroid belt. Five generic end-members are postulated: (1) water ice; (2) dry ice: carbon-carbon dioxide rich, (3) oceanic (chloride) ice; (4) sulfur-rich ice; (5) ammonia hydrate-rich ice; and (6) clathrate: methane-rich ice. Due to the volatile nature of these bodies, evidence for their impact with the Earth would be subtle and probably best reflected geochemically or in the fossil record. Actual boloids impacting the Earth may have a variable composition, generally some admixture with water ice. However for ...
1988-10-20
Traveling Wave RF Systems for Helical Cooling Channels
Energy Technology Data Exchange (ETDEWEB)
The great advantage of the helical ionization cooling channel (HCC) is its compact structure that enables the fast cooling of muon beam 6-dimensional phase space. This compact aspect requires a high average RF gradient, with few places that do not have cavities. Also, the muon beam is diffuse and requires an RF system with large transverse and longitudinal acceptance. A traveling wave system can address these requirements. First, the number of RF power coupling ports can be significantly reduced compared with our previous pillbox concept. Secondly, by adding a nose on the cell iris, the presence of thin metal foils traversed by the muons can possibly be avoided. We show simulations of the cooling performance of a traveling wave RF system in a HCC, including cavity geometries with inter-cell RF power couplers needed for power propagation.
2009-05-01
Thermo-economic analysis of solar powered adsorption heat pump
British Library Electronic Table of Contents (United Kingdom)
The economic feasibility of the residential solar thermal (ST) cooling system designed in the companion article [1] is ascertained by comparing it with a solar electric (SE) cooling system, and also with the baseline (i.e., control case), a grid dependent, highest efficiency COPC=5.66 heat pump. The economic scenario is analyzed for 24 cities across the southern USA, south of the 37degreeN. The SE cooling system provides lifecycle (20 year) savings to the homeowner only where electric rates are high and it is heavily subsidized. The overall societal effect (sum of taxpayer funded rebate and homeowner savings) is actually an increased cost everywhere except the California Central Valley, where the net savings is $1500. In the same valley, The ST cooling system provides greater lifecycle sav...
2007-01-01
Structural analysis and stress evaluation system for steel structures: ADAMS
Energy Technology Data Exchange (ETDEWEB)
In order to perform the structural analysis and stress evaluation for frame structures in the nuclear power plants, ADAMS (AIJ Design Analysis and Modules System) has been developed by the addition of the following functions to the ICES-STRUDL system. 1. Load combination and stress evaluation on the basis of specifications for designing steel structure (issued by the Architecture Institute of Japan). 2. Combination of load and stress evaluation of piping support on the basis of the regulations of Ministry of International Trade and Industry. 3. Addition of other functions than that described above. ADAMS enables structural analysis and stress evaluation exactly and efficiently not only for a large scale structure such as the pipe whip protection structure installed inside of the primary containment vessel for many loading cases but also for a large number of structures such as piping support. This ...
1980-11-01
System behavior after a loss of electric power in HANARO
International Nuclear Information System (INIS)
A LOss of Electric Power(LOEP) experiment was conducted after a 30MW full power operation as one of the reactor performance tests to verify the design characteristics of the HANARO. The objective of LOEP test was to investigate the integral behaviors of the system and the components as well as the cooling characteristics when the electric power was lost unexpectedly. Through the test, it was confirmed that the residual heat from the core was safely removed by the natural convection cooling and the assistant power systems operated normally
2005-04-11
International Nuclear Information System (INIS)
The liquid-metal-cooled fast breeder reactor presented includes a fuel assembly made up of several long sub-assemblies rising side by side. Each of the sub-assemblies of an external area of the fuel assembly comprises an electromagnetic braking system for regulating the flow of coolant in the sub-assembly, the magnetic fields of the braking systems being temperature sensitive.
Cooling of nuclear power stations with high temperature reactors and helium turbine cycles
International Nuclear Information System (INIS)
On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable ...
Emergency reactor core cooling device
International Nuclear Information System (INIS)
The device of the present invention improves reactor safety by suppressing lowering of water level in a shroud which surrounds a reactor core, even upon occurrence of rupture of pipelines in an emergency reactor core cooling system in a recycling pump-incorporated type reactor. Namely, an opening of each of cooling systems which forms the emergency reactor core cooling device in a reactor pressure vessel is disposed above the upper end of the reactor core. Further, it also comprises an independent high pressure water injection system, gravitational dropping type water injection system and an automatic depressurization system. With such a constitution, even if rupture of pipelines in the system should be assumed, coolants never flow directly from the shroud which surrounds the reactor core. In ...
1993-03-16
Calculation of current-carrying capacity of forced cooled high-voltage cable lines
Energy Technology Data Exchange (ETDEWEB)
The current-carrying capacity of oil-filled cables is increased by forced cooling, which is accomplished by three methods: direct, surface and internal, depending on the relative positions of the cable and the cooling agent. The surface and indirect methods are the simplest and are sufficiently effective methods of cooling and make it possible to improve the current-carrying capacity of cables already mastered by the USSR's industry. A calculation method is suggested for the proper determination of the permissible load on lines of these sorts. A procedure is presented whereby equations are derived which make it possible to calculate the temperature of elements of the system and by means of an iteration calculation a determination is made of the total heat flow from the cable with which the temperature of the conductor along the line does not exceed the permissible value. The permissible current ...
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
The Time Projection Chamber (TPC) magnet at LBL and its compensation solenoids are adiabatically stable superconducting solenoid magnets. The cryogenic system developed for the TPC magnet is discussed. This system uses forced two-phase tubular cooling with the two cryogens in the system. The liquid helium and liquid nitrogen are delivered through the cooled load by forced tubular flow. The only reservoirs of liquid cryogen exist in the control dewar (for liquid helium) and the conditioner dewar (for liquid nitrogen). The operation o these systems during virtually all phases of system operation are described. Photographs and diagrams of various system components are shown, and cryogenic system data are presented in the following sections: (1) heat leaks into the TPC coil package and the compensation ...
1980-03-01
Induction motor for tunnel exhauster; Tunnel haifukiyo yudo dendoki
Energy Technology Data Exchange (ETDEWEB)
A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)
2000-01-10
International Nuclear Information System (INIS)
Purpose: To obtain stabilized operation by preventing over heat in emergency cooling pumps upon accidents of flow regulators. Constitution: A pressure suppression chamber pool and a pressure vessel are communicated to each other with a pipeway and the water in the suppression pool is charged by a charging pump to the pipeway. The pipeway is interposed with an emergency cooling pump so as to feed water in the pipeway to the pressure vessel and a water source and the emergency cooling pumps are connected by way of a closed pipeway. Further, the closed pipeway and the pipeway interposed with the charging pump are communicated to each other by way of a connecting pipeway, to which are interposed an instrument for detecting the increase in the temperature of the emergency cooling pumps due to abnormality in the closed pipe (such as troubles in flow regulators) and outputting control signals and an ...
Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems
Energy Technology Data Exchange (ETDEWEB)
In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).
2006-03-01
Energy Technology Data Exchange (ETDEWEB)
For light water reactors, loss of coolant is an important point in safety analysis, whereas for gas-cooled reactors the ingress of water into the core region is an incident of safety relevance. The applicability of the computer code system GAMTEREX to pebble beds of spherical high-temperature gas-cooled reactor fuel elements with simulated water ingress is verified by experiment. The measurements were performed at a Siemens-Argonaut reactor, using its ring core as a driver zone for a pebble-bed core in the center of the reactor.
1987-09-01
Energy Technology Data Exchange (ETDEWEB)
After cooling ceilings and source ventilation, simple air conditioning systems like thermal activation of concrete cores are gaining general acceptance. Parallel to this, ground source cooling systems are reducing the need for cold generation. Air conditioning systems of this type are favoured by producers of floor heating systems looking for a new market segment. [German] Nach Kuehldecken und Quellueftung gewinnen jetzt einfach aufgebaute Raumklimaanlagen, wie die thermische Betonkernaktivierung, immer mehr Anhaenger. Parallel dazu werden Verfahren zur Erdkaeltenutzung entwickelt, die den Anteil kuenstlich erzeugter Kaelte weiter zurueckdraengen. Forciert wird diese Art der Klimatisierung insbesondere durch die Hersteller von Fussbodenheizungen, fuer die sich hier ein neues Marktsegment eroeffnet. (orig.)
1999-10-01
A risk based approach to assess the incidence of ice loads on small concrete dams
International Nuclear Information System (INIS)
Some considerations regarding ice load in risk-based dam safety analysis are presented for small concrete dams. The most significant physical mechanisms leading to ice thrust on dams (such as thermal expansion and water level fluctuations) are outlined. Published literature on dam ice loads to examine ice load magnitude-return period relationships, sliding and overstressing failure mechanisms and structural performance criteria to resist ice loads, are also reviewed. Related loading combinations for structural safety evaluations were determined regarding the issue of simultaneity of ice loads with other events such as earthquakes. Parametric analyses were conducted on a small gravity dam section, 3m high, and a taller dam, 17.9 m high, to demonstrate the ultimate ice load carrying capability as a function of dam geometry and shear and ...
Low-temperature brown rice storage by using renewable energy from snow
Energy Technology Data Exchange (ETDEWEB)
This paper reported on a study that was conducted in Japan to determine whether renewable energy generated from snow can be used to replace the cooling system and electricity used for cooling a rice storehouse that maintained the grain temperature below 15 degrees C. However, the low-temperature storage system required a cooling system and electricity to cool rice in summer. In this study, a snow pile using 890 t of snow was made at the beginning of March next to the rice storehouse. The shape of the snow pile was a trapezium, 17 x 23 m at the bottom and 4 x 10 m at the top and 5 m in height. The snow pile was covered with 200 to 300 mm of wood chips to act as an insulation layer. Approximately 27 per cent of the energy for cooling the rice storehouse could be replaced by using the snow pile in summer. The quality of ...
2010-07-01
Rural residential application of geothermal heat pump. Final grant report
Energy Technology Data Exchange (ETDEWEB)
A project to demonstrate residential heating and cooling with a well-water source heat pump is documented. The system is schematically illustrated and described, and project experience is discussed. The system is capable of using source water as cool as 40/sup 0/F. Project expenses are accounted for. (LEW)
1982-07-30
Thermal control of electric vehicle batteries
Energy Technology Data Exchange (ETDEWEB)
The need to operate electric vehicles in warm, summer conditions and also provide for long periods of standby in cold climates is a challenging problem for any battery system. All advanced batteries of high specific energy require active cooling systems because adiabatic heating will raise the temperature to a level that is deleterious to cycle life. This cooling requires efficient paths for escape of heat to cooled surfaces; cooling the exterior of modules is insufficient. If a battery is heated by its own energy, and insulated to withstand exposure to a cold climate, only vacuum insulation will afford an appreciable reduction (>10{degrees}C) in the ambient temperature that can be tolerated. Standard insulations are of little use for this purpose because the heat loss rate causes too high a drain on the battery energy even for near-ambient temperature ...
1995-07-01
British Library Electronic Table of Contents (United Kingdom)
In the last years, the growing demand for air conditioning has caused a significant increase in demand for primary energy resources. Solar-powered cooling is one of the technologies which allows to obtain, by using the renewable solar source, an important energy saving compared to traditional air conditioning plants. The paper describes different technical installations for solar cooling, their way of operation, advantages and limits. The objective of the present study has been to analyze the technical and economic feasibility of solar absorption cooling systems, designed for two different application fields: industrial refrigeration and air conditioning. The possibility to replace or integrate the existing plants is studied, by considering the refrigeration requirements of a company, whic...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.
2010-07-01
Air conditioning in high rise buildings; Conditionnement d'air dans les immeubles de grande hauteur
Energy Technology Data Exchange (ETDEWEB)
This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor air quality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)
1997-07-01
SUSTAINABLE H/C SYSTEMS FOR CHICKEN FARMS IN SYRIA
Energy Technology Data Exchange (ETDEWEB)
Space heating/cooling systems account for approximately 30% of the global energy consumption. Such systems contribute to global warming by emitting 0.39.1011 MWh of heat and 2.9.1010 tons of CO{sub 2}. There is a general understanding that the way to reduce global warming is a more efficient use of energy and increased use of renewable energy in all fields of the society. The poultry industry in the Mid East is an important business. There are e.g. 13000 chicken farms in Syria producing 172,000 ton of meat. This industry employs directly almost 150,000 people. The total investment in chicken farming is 130 BSP. Even though, the annual mean temperature in Syria is {approx}15-18 C the winter temperatures are close to freezing for two months. Since the chickens need a temperature of 21-35 C, depending on age, approximately 168.103 tons of coal (1170 GWh) is consumed for heating these plants. The chicken farms have no ...
2008-09-30
HPOF transmission-system economic-evaluation program. Final report
Energy Technology Data Exchange (ETDEWEB)
This report describes the successful development of a computer program for the analysis of the economic, thermal, and rating characteristics of HPOF underground transmission cables with forced cooling. With this program cable engineers can interactively analyze self-cooled and forced-cooled HPOF cable design alternatives. The program computes cable thermal characteristics and discounted costs so that the impacts of changes in design parameters can be estimated. This report provides a review of the currently available HPOF design options that can be considered. The HPOF economic analysis program is written in FORTRAN IV and was developed for interactive operation.
1983-01-01
Experimental 1 kW 20 cell PEFC stack
Energy Technology Data Exchange (ETDEWEB)
A 20-cell PEFC stack was designed and built. Resin impregnated graphite was used as bipolar plate material. The air cooling of the stack was optimized by introducing high surface structures into the open space of the cooling plates. At {eta} (H{sub 2} LHV) = 0.5 a power of 880 W was obtained under conditions of low gas-pressures of 1.15 bar{sub a}. The auxiliary power for process air supply and cooling at 880 W power is less than 7% of the power output, indicating that the described system may be operated at a high efficiency. (author) 5 figs., 2 refs.
1999-08-01
Emergency core cooling device for a reactor
International Nuclear Information System (INIS)
Purpose : To obtain an emergency core cooling device in a FBR type reactor by utilizing heat pipes which are not actuated at usual operation condition but actuated reliably upon emergency. Constitution : A system for injecting heat medium into heat pipes is provided. By injecting the heat medium into the heat pipes upon emergency to actuate the heat pipes, the reactor core is cooled. During normal reactor operation, the inside of the heat pipes is evacuated from a vacuum pump and no heat medium is filled therein, whereby unnecessary heat loss during the normal operation can be prevented. (Ikeda, J.).
1982-01-24
Results are reported from initial characterization tests on the environmental effects of the natural draft cooling tower of the Chalk Point Unit 3 oil-fired power plant located on the shore of Chesapeake Bay. Data are included on updraft air velocity, plume drift, and sea salt deposition in relation to meteorological conditions.
1976-05-01
International Nuclear Information System (INIS)
Various schemes of cooling have been investigated for the purpose of assessing potential benefits on the operational characteristics of the Syrian MNSR reactor. A detailed thermal hydraulic model for the analysis of MNSR has been developed. The analysis shows that an auxiliary cooling system, installed in the pool which surrounds the lower section of the reactor vessel, will significantly offset the consumption of excess reactivity due to the negative reactivity temperature coefficient, Hence, the maximum operating time of the reactor is extended. Compared with experimental data, the suggested model proves to be valid for the analysis of MNSR behavior under both steady state and transient conditions. (author)
2007-01-01
System Analysis for Decay Heat Removal in Lead-Bismuth Cooled Natural Circulated Reactors
Decay heat removal analyses for lead-bismuth cooled natural circulation reactors are described in this paper. A combined multi-dimensional plant dynamics code (MSG-COPD) has been developed to conduct the system analysis for the natural circulation reactors. For the preliminary study, transient analysis has been performed for a 100 MWe lead-bismuth-cooled reactor designed by Argonne National Laboratory (ANL). In addition, decay heat removal characteristics of a 400 MWe lead-bismuth-cooled natural circulation reactor designed by Japan Nuclear Cycle Development Institute (JNC) has been evaluated by using MSG-COPD. PRACS (Primary Reactor Auxiliary Cooling System) is prepared for the JNC's concept to get sufficient heat removal capacity. During 2000 sec after the transient, the outlet temperature shows increasing tendency up to the maximum temperature of 430 ...
2002-07-01
Performance characteristics of a natural circulation cooling/latent heat storage system
Energy Technology Data Exchange (ETDEWEB)
A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage medium were tested. As ...
1987-09-25
Parametric study of radiative cooling of solid antihydrogen. Master's thesis
Energy Technology Data Exchange (ETDEWEB)
A computer model of cryogenic system for storing solid antimatter is used to explore the radiative cooling-power requirements for long-term antimatter storage. If vacuum-chamber pressures as low as 10 to -18th power torr can be reached, and the rest of the large set of assumptions is valid, milligram quantities of solid antimatter could be stored indefinitely at 1.5 K using cooling powers of less than a microwatt. Many of the assumptions made are problematic and need verification, as they could potentially change the results greatly. The system modeled is a sphere of solid anti-parahydrogen at 1.5 K or below levitated in a spherical cryogenic vacuum chamber. The free matter gas in the chamber is assumed to be molecular hydrogen, and sublimation of both matter and antimatter is assumed to be negligible. The antihydrogen is assumed to be in thermal equilibrium, although annihilation-energy deposition is ...
1989-03-01
Four loss-of-flow accidents in the SEAFP first wall/blanket cooling system
Energy Technology Data Exchange (ETDEWEB)
This report presents the thermal-hydraulic analysis of four Loss-of-Flow Accidents (LOFAs) in the first wall/blanket cooling system of the alternative SEAFP reactor design. The LOFAs considered result from a loss of electrical power for the recirculation pump in the primary cooling circuit. The analyses have been performed using the thermal-hydraulic system analysis code RELAP5/MOD3. In the analyses, special attention has been paid to the transient thermal-hydraulic behaviour of the cooling system and the temperature development in the first wall and blanket. For the LOFA without plasma shutdown, significant loss of heat removal due to dryout occurs at the midplane of the outboard first wall cooling pipes about 41 s after pump trip. For the three LOFA cases with emergency plasma shutdown that have been studied, the temperature increase in ...
1994-07-01
International Nuclear Information System (INIS)
The justification, strategies, and technology options for implementing advanced district heating and cooling systems in the United States are presented. The need for such systems is discussed in terms of global warming, ozone depletion, and the need for a sustainable energy policy. Strategies for implementation are presented in the context of the Public Utilities Regulatory Policies Act and proposed new institutional arrangements. Technology opportunities are highlighted in the areas of advanced block-scale cogeneration, CFC-free chiller technologies, and renewable sources of heating and cooling that are particularly applicable to district systems.
2007-10-15
Safety considerations of active process water system shutdown for TAPP - 3 and 4
International Nuclear Information System (INIS)
Active Process Water (APW) System, provided as unitized closed loop system in Tarapur Atomic Power Project Units-3 and 4, serves to remove heat from various heat exchangers. One of the important loads served by APW system is shutdown cooling heat exchangers and if APW shutdown is taken then reactor cannot be maintained in cold shutdown condition. It is estimated that after 7 days of reactor shutdown, if about 20% of the normal cooling flow to shutdown cooling heat exchangers is provided then along with keeping PHT in cold shutdown state, reactor components, moderator, end shield water, calandria vault water and calandria vault concrete temperature can be maintained within technical specification limits for extended duration. (author)
2005-12-01
GSFC Earth-Sun Exploration Division - Sciences and Exploration ...
retrieve detailed aerosol and cloud particle size distribution and shape ...... but on rain types, and hydrometeor characteristics. ..... of ice streams, decreasing sea ice cover in the Arctic, poleward movement of forest cover, and ...
THE EFFECT OF THE ICE-SEPARATION CURVE ON THE ...
... However, the solution of the Stefan problem in this context becomes abruptly complicated, since within each zone, the differential equations ...
STUDY AND MODIFICATION OF CONVECTIVE STORMS
... small water or ice particles by impaction ... flight recording; principally the hydrometeor charge unit ... capability of directing aircraft movements by radio ...
1963-06-30
An Evaluation of the Severity of the January 1998 Ice Storm in ...
... storm. There was little damage to high-voltage transmission lines and communication towers in northern New England. ...
1998-04-01
Biochar is fantastic for enriching soil, and you can make it yourself. Screen capture from video of sea ice minimum for 2010. ...
Energy Technology Data Exchange (ETDEWEB)
Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a ...
1995-03-01
International Nuclear Information System (INIS)
Liquid metal cooling for the first wall and blanket of a magnetic confinement fusion reactor has various advantages. However, it has the disadvantages of large magnetohydrodynamic pressure drops and heat transfer deterioration under a strong magnetic field. Thus, the present authors have proposed cooling with a helium-lithium annular mist flow as well as the cooling with a liquid metal boiling flow, and as fundamental studies, investigated the effect of a magnetic field on the flow characteristics and heat transfer of liquid metal two-phase systems since the 1970s. In the present paper we summarize the important findings obtained from our experimental studies for (i) an air-mercury stratified flow in a horizontal rectangular channel, (ii) a helium-lithium annular mist flow in a horizontal rectangular channel, (iii) the mercury pool boiling on a horizontal surface, and (iv) air-mercury upward flows in a ...
Radius of thawing around an injection well and time of complete freezeback
An approximate method of calculating the radius of thawing around an injection well is presented. The method is based on the assumption that for a cylindrical system the position of the phase interface in the Stefan problem can be approximated through two functions: one function determines the position of the melting-temperature isotherm in the problem without phase transitions and the second function does not depend on time. The adjusted heating time concept was used to describe the first function. The second function is a known analytical relationship and is expressed in terms of ice content, thermal properties of thawed/frozen formations, formation temperature and the temperature of the injected fluid. Simple approximate formulae are suggested to estimate the duration of the freezeback period. To verify the proposed formulae, the results of numerical solutions were used. An example which shows that the duration of the 'safety period' (free ...
2006-06-01
Energy Technology Data Exchange (ETDEWEB)
Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet ...
1996-03-01
Investigation on natural convection decay heat removal for the EFR: Status of the program
International Nuclear Information System (INIS)
The European Research and Development Program on decay heat removal by natural convection for the European Fast Reactor (EFR) covers the calculational methods and the model experiments performed for code validation. The studies concentrate on important physical effects of the cooling modes within the primary system and the direct reactor cooling circuits and include fundamental tests as well as reactor experiments. (author)
1991-11-05
Dry storage concepts and their thermodynamic layout
International Nuclear Information System (INIS)
The two favourable dry storage concepts being under consideration in the Federal Republic of Germany are presented and the physical behaviour or natural convection cooling with air is explained. With the three examples cask store, vault storage horizontally and vertically arranged the main thermodynamical design parameters and their influence on the efficiency of the cooling system and on the temperature distribution inside the store and of the stored material are discussed. Moreover, the importance of the fulfilment and the harmony of all safety criteria and the difficulties while to do so are carried out especially with the vault store.
Combined-cycle cogen plant a successful good neighbor
Energy Technology Data Exchange (ETDEWEB)
This article describes a new natural-gas-fired combined cycle cogeneration plant in Bellingham, Washington. The topics of the article include community impact, siting constraints, natural gas fuel, the flexibility provided by the steam turbine, the cooling tower and pumps, air-quality, noise, and cooling water system constraints, and community relations program.
1993-04-01
Internal dose from tritium at Wolsung nuclear power plant
International Nuclear Information System (INIS)
Tritium is produced in large quantities at heavy water nuclear power reactors via the neutron activation reaction "2H(n,#gamma#)"3H. At Wolsung nuclear power plant which has a CANDU reactor, the tritium concentrations in coolant and in moderator systems are 1.5 Ci/Kg-D_2O and 35 Ci/kg-D_2O, respectively, after 12 years of operation. The airborne tritium concentration in main access area is normally less than 5 MPCa except short-term peaks. The average tritium concentrations in main access controlled areas are normally less than 100 MPCa. Tritium is mainly present in the air of workplace of CANDU reactors as a tritiated water vapour. Airborne tritiated water vapour enters the workers body via inhalation and absorption through skin and can result in a significant dose. The occupational doses from tritium at Wolsung NPP have been maintained below 1 man-Sv per year so far. The tritium contribution to the total plant man-Sv changes between 30 percent and 50 percent. For ...
1995-02-01
Energy Technology Data Exchange (ETDEWEB)
A large amount of industrial water is used for cooling the various process fluids in the petroleum purification factories as well as petroleum chemistry factories. Consequently, a lot of heat exchangers as the necessary constitutional instruments are made of carbon steel. Due to the most of the corrosions of the carbon steel occurring in such cooling water systems are pitting corrosions, the inhibition thereof is extremely important for the elongation of the life of the plants and the stable operation. In this paper, the influences of water quality fractions on pitting corrosion of carbon steel in cooling water circumstance are examined aiming at the fouling in the cooling water. The fouling in the cooling water does not only increase the amount of occurrence of pitting corrosion but also accelerates the progress of pitting corrosion enlarging the rust due to ...
1993-08-15
Venus surface power and cooling systems
British Library Electronic Table of Contents (United Kingdom)
A mission to the surface of Venus would have high scientific value, but most electronic devices and sensors cannot operate at the 450degreeC ambient surface temperature of Venus. Power and cooling systems were analyzed for Venus surface operation. A radioisotope power and cooling system was designed to provide electrical power for a probe operating on the surface of Venus. For a mission duration of substantial length, the use of thermal mass to maintain an operable temperature range is likely impractical, and active refrigeration may be required to keep components at a temperature below ambient. Due to the high thermal convection of the high-density atmosphere, the heat rejection temperature was assumed to be at a 500degreeC radiator temperature, 50degreeC above ambient. The radioisotope S...
2007-01-01
System for cooling primary gas coolers using return water stabilized by means of ammonium sulfate
Energy Technology Data Exchange (ETDEWEB)
Discusses scaling of closed systems for cooling coal gas from black coal coking. Scaling rate and factors that influence scaling are analyzed. Physical and chemical properties of scale buildup on the inner walls of pipe cooling systems are evaluated. Water pH value and its effects on scaling and solubility of chemical compounds that form scale are discussed. Use of ammonium sulfate for scale control is analyzed. Consumption rate of ammonium sulfate depends on ambient temperature, water pH value and chloride content in return water. Formulae for calculating optimum content of ammonium sulfates for scale control are derived. 3 refs.
1989-08-01
Process development for continuous crystallization of fat under laminar shear
British Library Electronic Table of Contents (United Kingdom)
A novel continuous laminar shear structuring crystallizer with a suitable cooling system was designed and built. This is a new method to continuously crystallize edible fat in the desirable polymorphic form from the melt while being uniformly sheared.The machine consists of four main sections: Feed unit, shearing mechanism, cooling system and power unit. In each of these sections specific design considerations are taken into account which makes the process controllable and continuous. The shearing unit is made of two concentric cylinders. The internal cylinder is stationary and has a cooling system inside for temperature control. The outer cylinder rotates to produce a uniform shear in the sample fluid placed in the 1.5mm gap between the cylinders. The sample's feed rate is controlled whil...
2008-01-01
Helium-cooling in fusion power plants
Energy Technology Data Exchange (ETDEWEB)
This paper reviews different helium-cooled first wall and blanket designs; and compares the selection of structural materials. The authors found that the solid breeder, SiC-composite material option generates the lowest amount of induced radioactivity and afterheat and has the highest temperature capability. When combined with the direct cycle gas turbine system, it has the potential to be the most economical fusion system and can compete with advanced fission reactors. When compared to martensitic steel and V-alloy, SiC-composite is the least developed of these three structural materials, a focused development effort will be needed. Fundamental research has begun in addressing the issues of optimized composite materials, irradiation effects, leak tightness and low activation braze materials. Development of helium-cooled high heat flux components and further development of the direct cycle gas turbine ...
1994-11-01
A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector
British Library Electronic Table of Contents (United Kingdom)
An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...
2007-01-01
British Library Electronic Table of Contents (United Kingdom)
A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...
2008-01-01
Designer's handbook for forced-cooled high-pressure oil-filled pipe-type cable systems. Final report
Energy Technology Data Exchange (ETDEWEB)
This handbook provides the necessary tools for the engineer to design forced-cooled HPOF pipe-type cable systems. It represents the final objective of a major project which included an extensive research program at the Waltz Mill Forced-Cooling Test Facility. The formulas and procedures presented in this handbook are consistent with the results of this program as well as other full-scale and model investigations. Introductory material, including historical information, general design concepts and basic heat transfer and fluid dynamics theory is given for those who are unfamiliar with the fundamental principles of forced-cooling. The nucleus of the handbook consists of equations and calculating procedures for determining forced-cooled parameters and thermal/hydraulic performance levels. Both simple and sophisticated procedures have been provided, with the more complex procedures ...
1984-07-01
Energy Technology Data Exchange (ETDEWEB)
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 ...
1999-06-19
Energy Technology Data Exchange (ETDEWEB)
Gas turbine component protection remains essential but environmental regulations emphasize the gas-turbine efficiency. Heating and cooling are features often integrated into the GI air intake packages to provide the optimum operating conditions. This paper describes modern inlet air treatment systems and discusses their effectiveness. (author)
1999-07-01
Mold heating and cooling microprocessor conversion. Final report
Energy Technology Data Exchange (ETDEWEB)
Conversion of the microprocessors and software for the Mold Heating and Cooling (MHAC) pump package control systems was initiated to allow required system enhancements and provide data communications capabilities with the Plastics Information and Control System (PICS). The existing microprocessor-based control systems for the pump packages use an Intel 8088-based microprocessor board with a maximum of 64 Kbytes of program memory. The requirements for the system conversion were developed, and hardware has been selected to allow maximum reuse of existing hardware and software while providing the required additional capabilities and capacity. The new hardware will incorporate an Intel 80286-based microprocessor board with an 80287 math coprocessor, the system includes additional memory, I/O, and RS232 communication ports.
1995-07-01
MR-6 type fuel elements cooling in natural convection conditions after the reactor shut down
International Nuclear Information System (INIS)
Natural cooling conditions of the nuclear fuel in the channel type reactor after its shut down are commonly determined with relatively high uncertainty. This is not only to he lack of adequate measurements of thermal parameters i.e. the residual power generation, the coolant flow and temperatures, but also due to indeterminate model of convection mechanism. The numerical simulation of natural convection in multitube fuel assembly in the fuel channel leads to various convection modes including evidently chaotic behaviour. To determine the real cooling conditions in the MARIA research reactor a series of experiments has been performed with fuel assembly equipped with a set of thermocouples. After some forced cooling period (the shortest was half an hour after the reactor shut down) the reactor was left with the only natural convection. Two completely different cooling modes have been observed. The MARIA ...
2002-03-17
Thermal gradient humidification-dehumidification desalination system
Energy Technology Data Exchange (ETDEWEB)
A solar energy desalination process utilizing solar radiation directly for the evaporation of salt water is described. Ambient air takes on water vapor as the air passes through an evaporative medium. It is then directed between a saline water-covered, solar absorbing surface and a solar collecting housing. The resulting heated and moisture-saturated air is cooled in a heat exchange means where condensation of fresh water occurs. Simultaneously, cool salt water is utilized as the cooling water in the heat exchange means, and takes on the heat of condensation given up by the condensing vapor. The heated salt water from the heat exchange means is partially directed over the solar absorbing surface, and at least a portion of it is also directed to wet the evaporative medium. Several optional sub-processes are described for operation of the system during periods of reduced insolation, and an alternative ...
1982-12-14
Liquid metal reactor cover gas purification and analysis in the USA
International Nuclear Information System (INIS)
Two sodium cooled reactors are currently being operated in the United States of America for the US Department of Energy. These are Experimental Breeder Reactor 11, EBR-11, and the Fast Flux Test Facility, FFTF. EBR-11 is located near Idaho Falls, Idaho, and the FFTF is near Richland, Washington. These reactors are currently engaged in a wide range of testing including fuels and materials tests, and plant system performance and safety development. The US DOE program also includes designs of a next generation sodium cooled power reactor. The FFTF and EBR-11 communities are providing input to these designs. This paper discusses the efforts to develop and operate cover gas systems for the sodium cooled nuclear reactor program in the USA.
1986-09-24
Horizontal ground coupled heat pump: Thermal-economic modeling and optimization
Energy Technology Data Exchange (ETDEWEB)
The modeling and optimizing processes of a Ground Coupled Heat Pump (GCHP) with closed Horizontal Ground Heat eXchanger (HGHX) are presented in this paper. After thermal modeling of GCHP including HGHX, the optimum design parameters of the system were estimated by minimizing a defined objective function (total of investment and operation costs) subject to a list of constraints. This procedure was performed applying Genetic Algorithm technique. For given heating/cooling loads and various climatic conditions, the optimum values of saturated temperature/pressure of condenser and evaporator as well as inlet and outlet temperatures of the water source in cooling and heating modes were predicted. Then, for our case study, the design parameters as well as the configuration of HGHX were obtained. Furthermore, the sensitivity analysis of change in the total annual cost of the system and optimum design parameters ...
2010-12-15
Energy Technology Data Exchange (ETDEWEB)
With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)
1993-07-01
Effect of the PVC system?s topology on the dielectric losses in the region of strong electric fields
British Library Electronic Table of Contents (United Kingdom)
The electrophysical characteristics of the electric cable?s transition into a state of a heterogenic polymer system due to a wire?s explosion were examined. Using cyclic heating-cooling of the composite, the changes in its topology were observed. The latter makes it possible to regulate the dielectric characteristics of the system.
2011-01-01
AUTOMATIC LIQUID NITROGEN PUMPING SYSTEM FOR PARTICLE ACCELERATORS
A description is given of an automatic liquid nitrogen pumping system. Pamping of liquid nitrogen iato cooling traps up to a predetermined level is achieved by an automatically controlled compressed air system. An impontant feature of the equipment is the ability to switch automatically from an empty liquid nitrogen reservoir to a full one. This allows for a much more flexible operation than in conventional systems where the reservoir has to be replaced manually when empty. (auth)
1963-04-16
Organometallic Polymer Coatings for Geothermal-Fluid-Sprayed Air-Cooled Condensers: Preprint
Energy Technology Data Exchange (ETDEWEB)
Researchers are developing polymer-based coating systems to reduce scaling and corrosion of air-cooled condensers that use a geothermal fluid spray for heat transfer augmentation. These coating systems act as barriers to corrosion to protect aluminum fins and steel tubing; they are formulated to resist the strong attachment of scale. Field tests have been done to determine the corrosion and scaling issues related to brine spraying and a promising organometallic polymer has been evaluated in salt spray tests.
2002-08-01
Energy Technology Data Exchange (ETDEWEB)
Why pay for energy when there`s a free stockpile of it right under your feet? With the help of a geothermal heat pump system, one can extract that energy from the ground and put it to good use, lowering heating and cooling costs. From private homes to public schools and fast-food restaurants, an increasing number of establishments are turning to geothermal heat pump systems for space conditioning. Experts say 1998 is already proving to be the best year yet for the technology, and they foresee an even more promising future. Some examples of geothermal energy use are given.
1998-05-01
Thermodynamic analysis of a hybrid geothermal heat pump system
British Library Electronic Table of Contents (United Kingdom)
A thermodynamic analysis of a hybrid geothermal heat pump system is carried out. Mass, energy, and exergy balances are applied to the system, which has a cooling tower as a heat rejection unit, and system performance is evaluated in terms of coefficient of performance and exergy efficiency. The heating coefficient of performance for the overall system is found to be 5.34, while the corresponding exergy efficiency is 63.4%. The effect of ambient temperature on the exergy destruction and exergy efficiency is investigated for the system components. The results indicate that the performance of hybrid geothermal heat pump systems is superior to air-source heat pumps.
2011-01-01
Isolation condenser passive cooling of a nuclear reactor containment
Energy Technology Data Exchange (ETDEWEB)
This patent describes a nuclear system comprising a containment airspace in which a nuclear reactor pressure vessel is disposed there being a reactor core within the pressure vessel. It comprises a heat exchanger elevated a distance above the pressure vessel; a pool of water surrounding the heat exchanger; means for venting the pool of water to an environment outside the containment; a heat exchanger entry conduit within the containment, the entry conduit having an open lower end communicating with the containment space, and an upper end connected to the heat exchanger, water-containing heated fluid present in the containment airspace incident a pressure vessel loss of coolant event entering and flowing through the entry conduit into the heat exchanger for cooling the fluid to convert water vapor therein to a condensate and separate non-condensable gasses therefrom; a gravity driven cooling water pond-containing space, the ...
1991-10-22
International Nuclear Information System (INIS)
In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection ...
1990-10-29
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one reported in this volume dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the ...
1981-05-01
Energy Technology Data Exchange (ETDEWEB)
The feasibility study on conceptual design methodology for accelerator-driven sodium-cooled sub-critical transmutation reactors has been conducted to optimize the design parameters from the scale laws and validates the reactor performance with the integrated code system. A 1000 MWth sodium-cooled sub-critical transmutation reactor has been scaled and verified through the methodology in this paper, which is referred to Advanced Liquid Metal Reactor (ALMR). A Pb-Bi target material and a partitioned fuel are the liquid phases, and they are cooled by the circulation of secondary Pb-Bi coolant and by primary sodium coolant, respectively. Overall key design parameters are generated from the scale laws and they are improved and validated by the integrated code system. Integrated Code System (ICS) consists of LAHET, HMCNP, ORIGEN2, and COMMIX codes and some files. ...
1998-12-31
Study on core cooling of hybrid safety system for next-generation PWR during LOCA
International Nuclear Information System (INIS)
Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the effect of ...
1995-04-23
Energy Technology Data Exchange (ETDEWEB)
This paper bundles 40 contributions by the IceCube collaboration that were submitted to the 30th International Cosmic Ray Conference ICRC 2007. The articles cover studies on cosmic rays and atmospheric neutrinos, searches for non-localized, extraterrestrial {nu}{sub e}, {nu}{sub {mu}} and {nu}{sub {tau}} signals, scans for steady and intermittent neutrino point sources, searches for dark matter candidates, magnetic monopoles and other exotic particles, improvements in analysis techniques, as well as future detector extensions. The IceCube observatory will be finalized in 2011 to form a cubic-kilometer ice-Cherenkov detector at the location of the geographic South Pole. At the present state of construction, IceCube consists of 52 paired IceTop surface tanks and 22 IceCube strings with a total of 1426 Digital Optical Modules deployed at depths up to 2350 m. The ...
2007-11-02
Energy Technology Data Exchange (ETDEWEB)
The aim of this study concerns the use of numerical methods for the resolution of the Reynolds Averaged Navier Stokes equations adapted to the simulation of the cooling of the trailing edge of a stator in a high pressure turbine. These methods, based on the elsA solver developed at ONERA, use a four steps Runge Kutta time discretization scheme and a Jameson centered space discretization scheme. The scheme is applied through a finite volume approach on control volume centered on the cells of a multi-block structured mesh. Turbulence is simulated either through the algebraic Michel model, or through the one-transport-equation Spalart-Allmaras model, or through the two-transport-equations k 1, k {omega} and k {epsilon} models, and through ASM model. A simulation of the flow in a bidimensional stator, without cooling, is carried out. The cooling, which is realized with trailing edge slots, is then simulated on a bidimensional ...
2004-09-15
Terra Nova tow-out poised as next East Coast event
Energy Technology Data Exchange (ETDEWEB)
This spring, Newfoundland will send off a floating production, storage and offloading (FPSO) vessel to the offshore Terra Nova field. The Terra Nova will proceed southeast through Bull Arm, then northeast out of Trinity Bay, then heads southeast to the Jeanne d'Arc Basin on the Grand Banks. The Terra Nova is expected to produce 115,000 barrels of oil per day for six years, when it reaches full capacity. The consortium, headed by Petro-Canada as senior ownership partner and operator, built an environment protection program into every aspect of the project. Some of the features of the environment protection program include glory holes excavated on the ocean floor for the protection of production equipment from icebergs, to a flare stack on the platform, which has four legs to provide stability in rough seas. The FPSO was designed to withstand sea ice, icebergs, and severe winter storms. Flow lines are also protected, and in the event that a line is damaged, ...
2001-01-15
Primary spinal epidural extraosseous Ewing's sarcoma: Report of five cases and literature review
International Nuclear Information System (INIS)
Ewing's sarcoma is the most common malignant bone tumour occurring in children and adolescents and exists in two different clinico pathological entities: osseous Ewing's sarcoma (OES) and extraosseous Ewing's sarcoma (EES). Five cases of primary epidural EES are described, which presented with non-specific symptoms leading to a long diagnostic delay. The median age at diagnosis was 22 years (range 13-36 years). The median diagnostic delay was 3 months. All patients had one or more neurological deficits. All underwent surgical exploration with a laminectomy and partial resection followed by adjuvant radiotherapy to a dose of 46-50 Gy and chemotherapy with VAC (vincristine, adriamycin and cyclophosphamide) alternating with ICE (ifosphamide, cisplatin and etoposide) for at least six cycles. The mean follow-up period is 21.2 months (range 11-32 months). Four of the five patients achieved a complete remission and are disease free at the time of writing this report. Two ...
2001-08-01
GOCE, Satellite Gravimetry and Antarctic Mass Transports
In 2009 the European Space Agency satellite mission GOCE (Gravity Field and Steady-State Ocean Circulation Explorer) was launched. Its objectives are the precise and detailed determination of the Earth's gravity field and geoid. Its core instrument, a three axis gravitational gradiometer, measures the gravity gradient components V xx , V yy , V zz and V xz (second-order derivatives of the gravity potential V) with high precision and V xy , V yz with low precision, all in the instrument reference frame. The long wavelength gravity field is recovered from the orbit, measured by GPS (Global Positioning System). Characteristic elements of the mission are precise star tracking, a Sun-synchronous and very low (260 km) orbit, angular control by magnetic torquing and an extremely stiff and thermally stable instrument environment. GOCE is complementary to GRACE (Gravity Recovery and Climate Experiment), another satellite gravity mission, launched in 2002. While ...
2011-03-01
Lamp system for uniform semiconductor wafer heating
Energy Technology Data Exchange (ETDEWEB)
A lamp system with a very soft high-intensity output is provided over a large area by water cooling a long-arc lamp inside a diffuse reflector of polytetrafluorethylene (PTFE) and titanium dioxide (TiO.sub.2) white pigment. The water is kept clean and pure by a one micron particulate filter and an activated charcoal/ultraviolet irradiation system that circulates and de-ionizes and biologically sterilizes the coolant water at all times, even when the long-arc lamp is off.
2001-01-01
Development of High-Efficiency Low-Lift Vapor Compression System - Final Report
Energy Technology Data Exchange (ETDEWEB)
PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.
2010-03-31
Thermal and radiation losses in a linear device
Energy Technology Data Exchange (ETDEWEB)
An analysis is presented of the electron temperature in a linear device which includes the effect of thermal conduction, heat flux limit, radiation, and end plugs. It is found that the thermal conduction and the heat flux limit are dominant in the initial phase of cooling, while the later phase is almost completely controlled by radiation that spatially homogenizes the temperature distribution. In the case of bremsstrahlung, within the frame of the present model, the temperature decays to zero in a finite time. This process takes the form of a cooling wave that moves from the ends of the column to the center. Impurities cause a milder, exponential decay, which is still much faster than the algebraic conduction decay. The thermal effectiveness of the end plugs is described by a convective transfer coefficient h/sub p/. Its scaling law (in terms of the coupled plamsa-plug system) reveals that a very high plug-plasma density ...
1980-11-01
Natural convection cooling of the IFMIF target and test cell
International Nuclear Information System (INIS)
The present work summarizes efforts on the simulation of natural convection cooling within the IFMIF target and test cell. The simulations have been performed with the STAR-CD code using the k-#omega# high-Reynolds number turbulence model. A dedicated thermohydraulic model has been devised including Lithium loop components. Nuclear heat production has been calculated by the Monte-Carlo code McDeLicious for different parts of the target and test cell walls and was used as input for the STAR-CD simulations. Helium atmospheres at several pressures from 0.1 to 10"-"5 MPa have been investigated. In order to limit the maximum temperature of the concrete walls to 80 deg. C it was necessary to add thermal insulation layers to the hot Lithium loop surfaces and a conceptual system of two cooling layers in different depths of the concrete walls.
2007-10-01
Furnace for rapid change of temperature for neutron diffraction
International Nuclear Information System (INIS)
A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.
Conceptual design of a low-temperature radiation-hard tracker detector
Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.
2003-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...
2011-01-01
Building design using the energy nomographs
Energy Technology Data Exchange (ETDEWEB)
Today's building industry is promoting the use of renewable sources of energy to heat, cool, and illuminate commercial buildings. Societies such as the International Solar Energy Society sponsor conferences such as this one to share knowledge and experience in the area of solar energy. However, the technologies presented here assume a need for heating, cooling or illumination. A simple technique is presented for determining the actual heating, cooling, and lighting requirements for commercial buildings, and for reducing those requirements through proper building design before applying solar technologies. The energy nomographs are a graphic energy design tool developed to aid designers in making cost effective decisions about energy alternatives early in the design process. Reducing loads at this point can help reduce the expense of a passive or active solar system which is usually sized to meet ...
1983-06-01
Integral air-conditioning system for electric cars. Integrales Klimasystem fuer Elektroautomobile
Energy Technology Data Exchange (ETDEWEB)
Increasing environmental awareness and new legislation in Europe and, in particular, America have accelerated the development of marketable electric cars which satisfy customer demands in terms of performance, range capability, safety and comfort. Tomorrow's electric cars will therefore require powerful heating and cooling systems for the passenger compartment which meet the conditions specific to this particular mode of transport and which do not overly affect the range capability of such vehicles. At Behr GmbH suitable system concepts were developed at a very early stage which were based on a high proportion of recirculated air, the use of the A/C unit as a heat pump, and heat recovery. This paper will examine two typical A/C systems which combine good heating and cooling characteristics with the low electric power requirement of only 1,5-2 kW. (orig.).
1992-11-01
Heavy water reactor facility large-scale containment cooling test program
The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic ...
1992-01-01
Heavy water reactor facility large-scale containment cooling test program
International Nuclear Information System (INIS)
The Heavy Water Reactor Facility (HWRF), as part of the defense-in-depth philosophy to mitigate the effect of design-basis and severe accidents, is equipped with a passive containment cooling system (PCCS). The function of the PCCS is to provide a safety-grade path to the ultimate heat sink for the removal of the reactor coolant system sensible heat and core decay heat. Ambient air enters an annular space between the steel containment shell and the surrounding concrete shield building through inlets in the shield building wall, is heated via natural convection, rises, and exits the building through a chimney located above the containment dome. A test program is in place to access parameters important to the effective operation of the PCCS. This paper focuses on the large-scale tests (LSTs). The objectives of these tests are as follows: (1) demonstrate natural circulation cooling with more prototypic ...
1992-11-15
Conceptual design of a medium scale lead-bismuth cooled fast reactor
International Nuclear Information System (INIS)
To seek for a promising concept of a heavy liquid metal coolant (HLMC) fast reactor plant, Japan Nuclear Cycle Development Institute and the electric utilities conducted conceptual design study on various types of plant concepts and compared these concepts based on technical feasibility and economical perspective. A comparative design study is performed on Lead-Bismuth cooled reactors with forced and natural convection cooling. Eliminating an intermediate cooling system makes the heat transport system simple and can decrease the amount of the weight of NSSS. Based on the estimation of the amount materials, the plant internal load etc., a construction cost of these plants are evaluated approximately 2/3 times of that of LWRs at present. And, the nitride fuel makes breeding ratio of 1.2 with 150 GWd/t of burnup. The results of unprotected event analyses such as UTOP and ULOF show that ...
2003-09-15
Report two. Safety offshore eastern Canada. Summary of studies and seminars
Energy Technology Data Exchange (ETDEWEB)
In 1982 the semi-submersible drilling unit Ocean Ranger capsized and sank off the Grand Banks, resulting in the loss of the entire 84-man crew. A Royal Commission was set up to conduct an enquiry into the incident, and to carry out a process of research and opinion-gathering towards providing recommendations to both federal and Newfoundland governments. The primary purpose of the Commission was to determine why the Ocean Ranger sank, why none of the crew were saved, and how to avoid similar disasters. A number of studies and seminars were held to focus expert knowledge and opinion in several key fields and to update studies and fill gaps in the data base. Summaries of selected study reports and the seminar proceedings are presented in the following areas: the environment, including ice, marine climatology, weather forecasting services, wave climatology, oceanographic information, and seabed information; design, including mobile offshore drilling rig design ...
1984-05-01
Solar expriment begins at Atlanta school. [George A. Towns Elementary School
The largest solar heating and cooling system undertaken to date is now operating at the George A. Towns Elementary School in Atlanta, Georgia. It is expected to provide more than 60 percent of the building's heating and cooling requirements, using commercially available components and techniques. The Towns project is a United States Energy Research and Development Administration-sponsored experiment. The principal components of the solar heating and cooling system designed for the school--the solar collector array, the existing gas-fired boiler, the absorption chiller, and hot and cold water underground tanks to provide thermal storage--are described. To derive maximum benefit from the experiment, the system is fully instrumented for accurate measurement of performance. Environmental data, including insolation and ambient temperture, humidity, and wind ...
1976-03-01
Production of blast furnace coke via novel briquetting system
A method of making high strength coke briquettes suitable for use as blast furnace coke comprising, (A) providing coal, (B) heating the coal at a temperature at or above the softening point of the coal to form partially carbonized char, (C) cooling the partially carbonized char below the softening point of the coal, (D) mixing the cooled partially carbonized char and tar to form a mixture of tar and partially carbonized char, (E) briquetting the mixture of tar and partially carbonized char to form briquettes of tar and partially carbonized char, (F) calcinating the briquettes to form high strength briquettes.
1982-12-07
Leak sealing on ancillary cooling circuits of CANDU reactors
International Nuclear Information System (INIS)
This paper discusses the remote plugging of leaks in inaccessible pipework, with main reference to small leaks which frequently appear in ancillary cooling water circuits of nuclear reactors. Initially developed to cure problems of the pre-stressed concrete pressure vessels of UK reactors, the ZORIC sealant has been used to repair leaking biological shield pipework on six CANDU reactors. ZORIC is based on a water-soluble epoxy resin and an aqueous suspension of a refined mineral clay. This paper describes the evolution of the sealant, the qualification and testing program, and their application to CANDU reactor systems. 2 refs., 6 figs.
1992-11-22
Development of commercial high temperature gas-cooled reactor in China
Energy Technology Data Exchange (ETDEWEB)
The high temperature gas-cooled test reactor HTR-10 achieved the first criticality in last December in Institute of Nuclear Energy Technology of Tsinghua University in Beijing. Fuji Electric and Nissho Iwai have a cooperative information exchange agreement on the commercialization of the HTGRs with INET, and held an information exchange meeting in last March in INET. INET has started a study on the modification of the HTR-10 to couple with gas turbine system and a pre-feasibility study on the commercial HTGR under the cooperation with China State Power Company. The experiences and abilities of INET in the field of the HTGR and the aggressive plan for commercialization of the HTGR in China are summarized and discussed. (author)
2001-07-01
When loss is more (for transmission towers) | SmartPlanet
... ice, hurricanes, and trees (less likely on high voltage transmission lines ) can bring down above ground power lines. Flooding, Leeching ground ...
Statistical description and estimation of ocean drift ice environments
Energy Technology Data Exchange (ETDEWEB)
Part I of this thesis is on long-term iceberg collision-risk assessment methods for fixed offshore structures. Estimates for the long-term probability that an iceberg will hit a fixed offshore structure are based on estimates of the total volume of produced iceberg, a model for the size distribution of icebergs and a description of how iceberg trajectories ``fill`` the plane (the ocean`s surface). Part II of the thesis discusses methods for analysis of low resolution data in the sense that the size of the area covered by each pixel is not small compared to the dominating floes. Still, this type of data can provide estimates of the ice extent (and hence the ice edge) and ice concentration. The estimates of the ice edge (at least) seem to be physically significant in the sense that ``in some way`` they can reflect ice drift in an image time sequence. A priori this is far from obvious. ...
1991-04-01
Phylogenetic Characterization of Virulence and Resistance Phenotypes of Pseudomonas syringae
UK PubMed Central (United Kingdom)
Individual strains of the plant pathogenic bacterium Pseudomonas syringae vary in their ability to produce toxins, nucleate ice, and resist antimicrobial compounds. These phenotypes...Full Text Available
2005-09-01
Parameter Estimation in Moving Boundary Problems
... Finally, the one dimensional, one phase Stefan problem is well known as a model for the melting of ice (see, eg, [5]). There are many approaches to ...
1988-05-01
NASAPerformance Report - NASA Technical Reports Server
test bed (ADTT) tools technology. Glenn. Research. Center: Aircraft icing training video for regional and cor- porate pilots. Numerical propulsion ...
Measurements of the concentration and composition of nuclei for cirrus formation
UK PubMed Central (United Kingdom)
This article addresses the need for new data on indirect effects of natural and anthropogenic aerosol particles on atmospheric ice clouds. Simultaneous measurements of the concentration and composition...Full Text Available
2003-12-09
MICRONUTRIENTS/TRACE ELEMENTS - Global Change Master Directory (GCMD)
Total concentrations of major and trace elements were determined in samples of the epilithic lichen Umbilicaria decussata from 24 ice-free areas in coastal ...
ENGLISH R. PD.-SNOW-ICE - The Gateway to Astronaut Photography of ...
Jul 26, 2011 ... The Gateway to Astronaut Photography of Earth hosts the best and most complete online collection of astronaut photographs of the Earth.
Decline in Arctic sea ice thickness from submarine and ICESat ...
estimates from 42 years of submarine records (19582000) described by ... area (DRA) of declassified submarine sonar measurements. (covering $38% of the ...
Debris/ice/TPS Assessment and Integrated Photographic Analysis of ...
assessment.Both frustumswerein excellentcondition.No missingTPSor debonds/ unbondswere ...... 2) The average time for a 360 degree rotation was 29.9 seconds. ...
A comparison of benthic biodiversity in the North Sea, English ...
A comparison of benthic biodiversity in the North Sea, English Channel, and Celtic Seas. ICES J. Mar. Sci./J. Cons. int. Explor. Mer 56: 228-246. ...
The Bevatron liquid nitrogen circulation system
A nitrogen liquefier and computer controlled valving system have been added to the Bevatron cryoliner vacuum system to cut operating costs by reducing liquid nitrogen consumption. The computer and interface electronic systems, which control the temperatures of twenty-eight liquid nitrogen circuits, have been chosen and designed to operate in the Bevatron's pulsating magnetic field. The nitrogen exhaust is routed back to a liquefier, of about five kilowatt capacity, liquefied, and rerouted through the cooling circuits. A description of the system and operating results are presented.
1987-03-01
Reconsidering the site requirements for NPP on Olt River
International Nuclear Information System (INIS)
Site studies for CANDU type NPP began in a careful manner since 1982 as a first part of the Nuclear Power Plant Romanian Program adopted by political and governmental authorities at the time. A team was charged to develop all packages of the necessary main studies. The first Romanian NPP CANDU 6 type reactor gone to erection on Cernavoda site, planned to have 5 units and, like Wolsong NPP, applied the same design for the nuclear island. For the BOP parts the ANSALDO-GE project was applied with a thorough concern about requirements raised by connection to NSP. The first mission of design and research multi-branch team was to adapt the NPP Cernavoda project having an open water cooling circuit 'once-through' to the new parameters of a close recirculation water cooling circuit. Also, the structural design was re-evaluated for the case of soft foundation strata instead of hard rock ones. The close recirculation water cooling ...
2009-10-12
Multipass laser mass spectrometer with extreme jet-cooled pulsed gas
International Nuclear Information System (INIS)
We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes ...
2006-09-01
Improvement of local air coolers model in ISAAC
Energy Technology Data Exchange (ETDEWEB)
The purpose of this paper is to assess a new local air coolers model in ISAAC 2.0, as ISAAC 1.0 could model local air coolers only at two locations. In the new model, local air coolers up to twelve locations could be handled. Large LOCA and loss of feed water sequences were selected for the model comparison. Two cases were analyzed with ISAAC 2.0: one with 6 local air coolers in one of the fueling machine room and in the steam generator room, respectively, and the other with 3 local air coolers at both fueling machine room and 6 local air coolers in the steam generator room. The study assumes that the safety systems such as emergency core cooling system, shield cooling system and moderator cooling system are unavailable. According to the ISAAC 2.0 results, the new local air coolers model showed almost no difference between two cases. Also it ...
2004-02-01
Numerical analysis of a natural convection cooling system for radioactive canisters storage
International Nuclear Information System (INIS)
This paper describes the use of numerical analysis for studying natural convection cooling systems for long term storage of heat producing radioactive materials, including special nuclear materials and nuclear waste. The paper explains the major design philosophy, and shares the experiences of numerical modeling. The strategy of storing radioactive material is to immobilize nuclear high-level waste by a vitrification process, convertion it into borosilicate glass, and cast the glass into stainless steel canisters. These canisters are seal welded, decontaminated, inspected, and temporarily stored in an underground vault until they can be sent to a geologic repository for permanent storage. These canisters generate heat by nuclear decay of radioactive isotopes. The function of the storage facility ventilation system is to ensure that the glass centerline temperature does not exceed the glass transition temperature during ...
1995-02-01
Energy Technology Data Exchange (ETDEWEB)
In the context of the special research area 561 (Thermally highly loaded, open-porous and cooled multi-layer systems for combined-cycle power stations), the actual technical and scientific realizations are to be extended and new scientific bases are to be created in order to realize total efficiencies of 65 %. In addition, innovative material solutions and new concepts must be compiled for the cooling and drainage. Under this aspect, the author of the contribution under consideration reports on the development of open-porous multi-layer systems for steam turbines of the 700 C technology. It results an efficiency potential of 12 % and a potential of 15 % with the reduction of CO{sub 2} in relation to the actual state of the art. Thereby, the potential of future combined-cycle power stations is not yet exhausted.
2008-07-01
Energy Technology Data Exchange (ETDEWEB)
An emergency shutdown system for high-temperature gas-cooled pebble-bed reactors is proposed in addition to the common absorber rod shutdown system. This system is based on the strongly absorbing effect of small boronated graphite spheres (called KLAK), which trickle in case of emergency by gravity from the top reflector into the reactor core. The inner reflector of the Siemens-Argonaut reactor was substituted by an assembly of spherical Arbeitsgemeinschaft Versuchsreaktor fuel elements, and the shutdown effect was examined by installing well-defined KLAK nests inside this assembly. The purpose was to develop and prove a calculational procedure for determining criticality values for assemblies of large fuel spheres and small absorbing spheres.
1987-09-01
Natural convection cooling of liquid metal systems
International Nuclear Information System (INIS)
The recognition that natural convection offers the prospect of an important inherent safety feature for liquid metal cooled reactor systems has provided the impetus for a world-wide research effort over the past decade. Whilst this research has been based on experiment, both plant experiments and out-of-pile experiments, the enormous advances in the development of computing power in recent years have enabled complementary programmes of mathematical modelling through numerical simulation of the transport equations in three spatial dimensions. These not only offer considerable promise for the designer in projecting the behaviour from experiments and prototype plant to full scale plant, they have also proved to be of considerable value in helping us to interpret and understand the results of the experiments themselves. This paper attempts to review the progress made with the emphasis on decay heat removal by natural convection in the pool-type ...
Toxicity of radioactive wastes generated from PEACER spent fuel
Energy Technology Data Exchange (ETDEWEB)
Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially {sup 90}Sr and {sup 137}Cs are dominant contributor nuclides until 30 years and especially {sup 90}Sr and {sup 137}Cs have the highest activity and decay heat than other LLFP. In this study, recovery of {sup 90}Sr and {sup 137}Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years ...
2003-10-01
Toxicity of radioactive wastes generated from PEACER spent fuel
International Nuclear Information System (INIS)
Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyroprocessing. In the assessment of Long-Lived Fission Products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26E+05 after 100 years cooling, 1.97E+04 after 300 years cooling, 9.52E+03 ...
2003-10-01
Toxicity of Radioactive Wastes Generated from PEACER in Korea
International Nuclear Information System (INIS)
Assessment on the back end fuel cycle, in PEACER (Proliferation-resistant Environmental-friendly Accident-tolerant Continuable and Economical Reactor) that was designated as a new transmutation concept, was performed. Recovery system of uranium and TRU for PEACER is based on pyro-processing. In the assessment of long-lived fission products (LLFP) wastes, initially "9"0Sr and "1"3"7Cs are dominant contributor nuclides until 30 years and especially "9"0Sr and "1"3"7Cs have the highest activity and decay heat than other LLFP. In this study, recovery of "9"0Sr and "1"3"7Cs is recommended for reducing of wastes loading. The acceptable decontamination factor is investigated by the toxicity of PEACER spent fuel. The acceptable decontamination factor is about 1.02 E+05 for the actinides from PEACER spent fuel after 10 years cooling, 4.26 E+05 after 100 years cooling, 1.97 E+04 after 300 years cooling, 9.52 E+03 ...
2006-06-04
Energy Technology Data Exchange (ETDEWEB)
The objective of the project was to provide a readily understandable and usable methodology for preliminary analysis of the economic benefit that can accrue from the use of thermal energy storage for building heating and cooling. The procedure was to be capable of providing an estimate of cooling plant and storage size, as well as the monthly savings that can be saved. The research focused on the development of a procedure for a limited class of commercial and institutional buildings in North Carolina. A simplified procedure for analyzing the potential for using thermal energy storage (TES) in such buildings in North Carolina was developed. The procedure developed consists of charts and nomographs that can be used for estimating the size of TES systems, and for estimating the monthly demand savings. The monthly demand savings can be combined with the applicable rate schedule to determine the annual cost savings. An overview ...
1981-06-30
Natural circulation cooling in US Pressurized Water Reactors
International Nuclear Information System (INIS)
This document is a synthesis of data and analysis concerning natural circulation cooling in US Pressurized Water Reactors during off-normal operation and accident transients. Its objective is the integration of important research findings concerning PWR natural circulation phenomena into a single reference document. Sources of information include the Nuclear Regulatory Commission, reactor vendors, utility sponsored research groups, utilities, national laboratories, research reports, meeting papers, archival literature, and foreign sources. Three modes of natural circulation are discussed: single-phase, two-phase, and reflux/boiling condensation. General characteristics, analytical expressions, noncondensible gas effects, secondary effects, and nonuniform flow are described with regard to each of the natural circulation modes. Plant operational data, tests in scaled experimental facilities, and analysis with thermal hydraulic system codes have ...
Evaluation of advanced technologies for power transformers. Final report
Energy Technology Data Exchange (ETDEWEB)
The high insulating strength of certain gases, such as sulfur hexafluoride, when used at high pressure, suggests that there may be advantages to compressed gases as the insulating fluid in power transformers. However, simply exchanging the oil for compressed gas in an otherwise conventional transformer design will not yield a significant overall advantage. Compressed gases present the engineer with properties which are quite different from mineral oil. If gases are to be used as the major insulating fluid in power transformers, then virtually all aspects of the insulation and cooling of the apparatus must be reconsidered, affording an opportunity to introduce new design concepts, new materials, and new construction techniques. In this program, the feasibility of using the following principal design concepts has been explored: sheet conductors for the windings; a system of sealed, self-contained, annular cooling ducts ...
1981-01-01
Ship of challenges: Braced for perfect storms, icebergs and oilfield hazards
Energy Technology Data Exchange (ETDEWEB)
More details about the construction of the Terra Nova floating production, storage and offloading (FPSO) vessel are provided. The vessel was built in the Daewoo shipyard in South Korea, and is now undergoing final fitting at Bull Arm, near St. John's, Newfoundland. When complete, the vessel will operate 350 km offshore, southeast of St. John's. It is 291 metres long and 45.5 metres wide and has a capacity of 960,000 barrels of oil. Although the FPSO will hold less than half of the last giant supertanker which sailed for Irving Oil, it has a crew of 81, four times the size of the supertanker, reflecting the technical uniqueness of the vessel and the intense pre-occupation with safety associated with the combination of winds, ice, waves, and shallow water around the Grand Banks. Also described is the alliance system of partnership between the oil companies and the main contractors. The deal stipulates that if the project ran ...
2001-08-06
Respect distances. Rationale and means of computation
Energy Technology Data Exchange (ETDEWEB)
Canisters with spent nuclear fuel can obviously not be located within deformation zones as this might jeopardise their long term mechanical stability and thereby constitute a potential hazard to the biosphere. Less apparent, but equally important, is the fact that earthquakes trigger reactivation, slip, of structures some distance from their hypocentres due to, among many other factors, stress redistribution. Fault slip across a deposition hole might damage the isolation capacity of the canister and thereby jeopardise the overall integrity of the barrier system. Therefore, the following question might be posed: What is the distance from a deformation zone beyond which a canister can be safely emplaced? This respect distance cannot be readily computed because, unknown future events aside, there are some complicated aspects that need to be addressed e.g. degree of conservatism, scale, our ability to model ice sheets and earthquakes, etc. In this ...
2004-12-01
Hybrid electric vehicles and electrochemical storage systems - a technology push-pull couple
Energy Technology Data Exchange (ETDEWEB)
In the advance of fuel cell electric vehicles (EV), hybrid electric vehicles (HEV) can contribute to reduced emissions and energy consumption of personal cars as a short term solution. Trade-offs reveal better emission control for series hybrid vehicles, while parallel hybrid vehicles with different drive trains may significantly reduce fuel consumption as well. At present, costs and marketing considerations favor parallel hybrid vehicles making use of small, high power batteries. With ultra high power density cells in development, exceeding 1 kW/kg, high power batteries can be provided by adapting a technology closely related to consumer cell production. Energy consumption and emissions may benefit from regenerative braking and smoothing of the internal combustion engine (ICE) response as well, with limited additional battery weight. High power supercapacitors may assist the achievement of this goal. Problems to be solved in practice comprise battery management to ...
1999-12-01
Thermal hydraulic test for core cooling system using steam generators
Energy Technology Data Exchange (ETDEWEB)
As a candidate of the new concept safety system for the next generation PWR in Japan, the hybrid safety systems, which are combination of the active and the passive safety systems, and passive core cooling system by natural circulation in the reactor coolant loop with horizontal-type steam generators during Loss of Coolant Accidents (LOCAs) are investigated. The passive safety systems are advanced accumulators (ACC), primary-side and secondary-side automatic-depressurization systems (ADS, SADS), and a gravity-driven safety injection system (GDI). The horizontal steam generator design avoids a siphon break caused from the accumulation of non-condensable gases in the tubes by using a vent line in the channel head of the steam generators. This study investigates the passive core cooling characteristics ...
1999-07-01
The Philadelphia Marriott: A convention center flagship hotel
Energy Technology Data Exchange (ETDEWEB)
This article describes the state-of-the-art HVAC system at the Philadelphia Marriott Hotel. Thermal comfort and indoor air quality are emphasized. The system uses a hybrid gas absorption/electric centrifugal chilled water plant, variable flow pumping, water-side economizers to provide free cooling, central air handling units with air-side economizers and flow monitoring equipment.
1997-01-01
Operational test report integrated system test (ventilation upgrade)
Energy Technology Data Exchange (ETDEWEB)
Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.
1999-10-05
Method of controlling the coolant level in the cooling system of a nuclear power plant
International Nuclear Information System (INIS)
Object: To prevent a sudden drop in the level of a coolant in a annular pipe encased within a downcomer pipe. Structure: The coolant levels in annular pipes encased within downcomer pipes are simultaneously measured by level gauges which generate signals representative of coolant levels. The signals are fed to a level control system which will actuate valves to regulate the cover gas pressure in order to average the level differences among the annular pipes in different downcomer pipes. (Kamimura, M.).
Electric power generation. Thermal power generating systems. 2. rev. and enl. ed.
International Nuclear Information System (INIS)
This is a manuscript for a lecture contents: 1. Steam power and fundamentals of the steam power process, 2. conventional, nuclear and other steam generation processes, 3. cooling systems for steam power plants, 4. gas turbine power plants and combined-cycle power plants, 5. cogeneration, 6. development of thermal power plants and environmental effects. (orig.).
Electric power generation. Thermal power generating systems
International Nuclear Information System (INIS)
This is a manuscript for a lecture contents: 1) Steam power and fundamentals of the steam power process, 3) conventional, nuclear and other steam generation processes, 4) cooling systems for steam power plants, 5) gas turbine power plants and combined-cycle power plants, 6) cogeneration, 7) development of thermal power plants and environmental effects. (GL).
Study on Control of Brain Temperature for Brain Hypothermia Treatment
The brain hypothermia treatment is an attractive therapy for the neurologist because of its neuroprotection in hypoxic-ischemic encephalopathy patients. The present paper deals with the possibility of controlling the brain and other viscera in different temperatures from the viewpoint of system control. It is theoretically attempted to realize the special brain hypothermia treatment to cool only the head but to warm the body by using the simple apparatus such as the cooling cap, muffler and warming blanket. For this purpose, a biothermal system concerning the temperature difference between the brain and the other thoracico-abdominal viscus is synthesized from the biothermal model of hypothermic patient. The output controllability and the asymptotic stability of the system are examined on the basis of its structure. Then, the maximum temperature difference to be realized is shown ...
2003-01-01
International Nuclear Information System (INIS)
Object: To prevent coolant inventory within a cooling system loop in an atomic power plant from being varied depending on loads thereby relieving restriction of varied speed of coolant flow rate to lowering of a liquid surface due to short in coolant. Structure: Instruments such as a superheater, an evaporator, and the like, which constitute a cooling system loop in an atomic power plant, have a plurality of free liquid surface of coolant. Portions whose liquid surface is controlled and portions whose liquid surface is varied are adjusted in cross-sectional area so that the sum total of variation in coolant inventory in an instrument such as a superheater provided with an annulus portion in the center thereof and an inner cylindrical portion and a down-comer in the side thereof comes equal to that of variation in coolant inventory in an instrument such as an evaporator similar to the superheater. which ...
Energy Technology Data Exchange (ETDEWEB)
A multi-faceted research program has been performed to investigate in detail several aspects of free and forced convective cooling of underground electric cable systems. There were two main areas of investigation. The first one, reported in Volume 1, dealt with the fluid dynamic and thermal aspects of various components of the cable system. In particular, friction factors for laminar flow in the cable pipes with various configurations were determined using a finite element technique; the temperature distributions and heat transfer in splices were examined using a combined analytical numerical technique; the pressure drop and heat transfer characteristics of cable pipes in the transitional and turbulent flow regime were determined experimentally in a model study; and full-scale model experimental work was carried out to determine the fluid dynamic and thermal characteristics of entrance and exit chambers for the ...
1981-05-01
UK PubMed Central (United Kingdom)
Fluorescent microspheres were applied in a novel fashion during subsurface drilling of permafrost and ground ice in the Canadian High Arctic to monitor the exogenous microbiological contamination of...Full Text Available
2005-02-01
UK PubMed Central (United Kingdom)
The abundant microbial population in a 3,043-m-deep Greenland glacier ice core was dominated by ultrasmall cells (<0.1 μm3) that may represent intrinsically small organisms...Full Text Available
2005-12-01
Cooling facility for reactor container
International Nuclear Information System (INIS)
Cooling water is sprayed on the outer surface of an upper portion of a container, and a pool is formed by the cooling water flowing down while cooling the container. Further, the cooling water stored in the cooling water pool is recycled by a pump for spraying the cooling water on the outer surface of the upper portion of the container. Sufficient amount of cooling water is supplied for spraying the cooling water to the outer surface of the upper portion of the container so that the outer surface of the container is free from drying and a liquid membrane is formed on the entire surface. The amount of the cooling water is made greater than that of the cooling water evaporated when the entire amount of the heat generate in the reactor core of the reactor is transferred to the ...
1993-05-07
Surface wettability effect on an indirect evaporative cooling system
Energy Technology Data Exchange (ETDEWEB)
Indirect evaporative air coolers that use air-to-air plate-type heat exchangers show good promise (compared with compression air-conditioning systems) of extending the energy savings from arid, low-humidity areas to more widespread climatic conditions. However, no systematic experiment had been done concerning the effect of the wettability of aluminum plates on the effectiveness of the indirect evaporative cooling system. In this study, a testing apparatus was built where only one secondary channel and two primary channels were used so that different surfaces could be easily tested to determine the system`s effectiveness and the heat transfer coefficient. The advantage of this experimental apparatus is that plates of the heat exchanger can be easily changed in the test section instead of fabricating a complete heat exchanger for each test. A dynamic contact analyzer was used to quantitatively measure ...
1996-11-01
Thermoelectrically cooled water trap
Energy Technology Data Exchange (ETDEWEB)
A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.
2006-02-21
Joule-Thomson cryogenic cooler with extremely high thermal stability
An 80-K Joule-Thomson (J-T) cooling system designed for the Probe Infrared Laser Spectrometer (PIRLS) proposed for the Huygens Titan Probe of the Cassini Saturn orbiter mission is presented. The cryogenic cooling requirements of the PIRLS instrument are listed, and the cooler system design including details of a J-T cryostat, cold head, and dewar design is described along with the results of a thermal modeling effort and lab cooler performance testing. It is shown that by using active feedback temperature control of the cold head in combination with the self-regulating action of the J-T cryostat, a temperature stability of less than 0.1 mK/min is achieved by the cooler weighting 1.8 kg.
1991-06-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the study of the heat transfer and of thermal behaviour of the HF (high frequency) components (in fact capacitors) of the ITER-proto-2005-FCI antenna. Preliminary results carried out with the Castem software show that it is possible to cool the hottest part of the antenna efficiently. A water flow (1 bar, 25 Celsius degrees) or an helium flow (10 bars, 50 Celsius degrees) permit to limit the maximal value of the temperature to 270 Celsius degrees. A second software Ansys has allowed the author to simulate capacitors with more complicated shapes. (A.C.)
2003-07-01
British Library Electronic Table of Contents (United Kingdom)
A study of the ordinary mild steel/cooling water interface, with and without inhibitor, was carried out using electrochemical impedance spectroscopy (EIS). EIS spectra in uninhibited medium reveal that a layer of corrosion and scale products is formed naturally and evolves with the immersion time. Monosaccharides derivatives were used as corrosion inhibitors. Most of them exhibit good behaviour against corrosion of ordinary steel in simulated water systems. Their inhibiting efficiency increases with concentration rise and depends on molecular structure especially -OH groups' position on two adjacent carbons and their number. In addition, the effect of MoO4^2^- on the corrosion inhibition in the presence of the best inhibitor was also studied by EIS. The addition of MoO4^2^- enhanced the in...
2009-01-01
The year 2000 embedded systems problem to maintain the safety of nuclear installations
International Nuclear Information System (INIS)
The Y2K problem may impact on nuclear installations in a number of ways because embedded systems are used in nuclear routine operation, monitoring and control system. The very simplest embedded systems are capable of performing only a single function or set of functions to meet a single predetermined purpose. In more complex systems the functioning of the embedded system is determined by an application program that enables the embedded system to be used for a particular purpose in a specific application. The simplest devices consist of a single microprocessor which may itself be packaged with other chips in a hybrid system or Application Specific Integrated Circuit (ASIC). Its input comes from a detector or sensor and its output goes to a switch or activator which may start or stop the operation of a positioning motors or, by operating a ...
1999-02-01
Thermal performance of phase change wallboard for residential cooling application
Energy Technology Data Exchange (ETDEWEB)
Cooling of residential California buildings contributes significantly to electrical consumption and peak power demand mainly due to very poor load factors in milder climates. Thermal mass can be utilized to reduce the peak-power demand, downsize the cooling systems, and/or switch to low-energy cooling sources. Large thermal storage devices have been used in the past to overcome the shortcomings of alternative cooling sources, or to avoid high demand charges. The manufacturing of phase change material (PCM) implemented in gypsum board, plaster or other wall-covering material, would permit the thermal storage to become part of the building structure. PCMs have two important advantages as storage media: they can offer an order-of-magnitude increase in thermal storage capacity, and their discharge is almost isothermal. This allows the storage of high amounts of energy without ...
1997-04-01
Low temperature humidification dehumidification desalination process
Energy Technology Data Exchange (ETDEWEB)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to ...
2006-03-01
Low temperature humidification dehumidification desalination process
International Nuclear Information System (INIS)
The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to ...
2006-03-01
International Nuclear Information System (INIS)
The studies of forced jet augmentation of natural convection heat transfer are introduced. It investigates experimentally mixed convection and heat transfer augmentation by forced jets in a large rectangular enclosure with a vertical cooling surface. The experiment is designed to measure the key parameters governing the heat transfer augmentation by a forced jet, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio, on conditions simulating those of actual passive containment cooling systems and scales approaching those of actual containment buildings or compartments. The tests that cover a variety of injection modes will contribute to reveal the nature of mixing and stratification phenomena under accident conditions to a new generation of inherently safe reactors. With similarity considerations on governing equations, the ...
2010-02-01
Thermal-hydraulic testing on a Mitsubishi simplified PWR
Energy Technology Data Exchange (ETDEWEB)
Mitsubishi is now developing a new Pressurized water reactor (PWR), the Mitsubishi simplified PWR (MS-PWR), which has the innovative features of hybrid safety systems (an optimum combination of passive and active systems) and cooling by horizontal steam generators. In order to confirm the feasibility of the Mitsubishi hybrid safety system, various kinds of safety analyses are performed for loss-of-coolant accident events. In parallel to these safety analysis efforts, the following thermal-hydraulic tests are to be performed: (1) thermal-hydraulic test of a horizontal steam generator; (2) integrated thermal-hydraulic test using a simulation loop for the innovative MS-PWR (SLIM).
1993-01-01
Review of Cardiff telephone exchange total energy system after three years operation
Energy Technology Data Exchange (ETDEWEB)
A self contained continuous power generation system as described at INTELEC 1979, was successfully commissioned and put into service in a major communications centre at Cardiff in Wales. The objective was to provide all telecommunications equipment and electrical building engineering services from a dual fuel enginegenerating plant, and to recover waste heat energy to heat or cool the building. The plant, which is fully automatic, comprises five 1300kW engines using natural gas or diesel oil, and associated waste heat boiler and chiller systems. This paper reviews the functioning of the plant during its first three years of operation.
1983-10-01
Comparison of fuzzy control systems for hypothermal brain temperature regulation
British Library Electronic Table of Contents (United Kingdom)
The automatic control system for brain tissue temperature is studied theoretically for brain hypothermia treatment. In order to realize a human-friendly control mechanism, an automatic temperature regulation system is constructed to simulate brain hypothermia treatment by introducing a fuzzy algorithm for possible characteristic changes in patients. The brain temperature model is successfully realized to follow the desired temperature course automatically. The model reference fuzzy control of brain temperature based on water-cooling blankets is verified for clinical application to brain hypothermia treatments through various kinds of simulation experiment.
2007-01-01
Inherent safe heat removal in advanced medium-sized high-temperature reactors
International Nuclear Information System (INIS)
One of the main points for the inherent safety of a pebble bed high temperature reactor (HTR) is to guarantee the safe removal of the after-heat in case of a break-down of all active cooling systems like heat-exchangers or liner-cooling. This will be necessary because it is well known today that graphite pebble bed fuel elements stay intact, if the accident temperature is below 1600 deg. C. Therefore the heat must be taken out of the reactor system by passive, natural law heat-transfer mechanism so that the maximum fuel temperature stays below the specified limit. Today medium-sized HTRs with a power of 750 MW_t_h and more (TGTR-300, HTR 500) reach temperatures of more than 2400 deg. C in small parts of the core in such hypothetical accidents. A possible way to realize the inherent safe heat removal in advanced medium-sized HTRs is to change the form of the core. Instead of employing the standard ...
1990-04-01
ECCS integrated test in TAPP-3 and 4
International Nuclear Information System (INIS)
Emergency Core Cooling System (ECCS) is a safety critical system provided to mitigate the consequence of Loss of Coolant Accident (LOCA) in PHWR. Unlike 220MWe, all header injection has been introduced in 540MWe to simplify the logic. ECCS Integrated Test is schematic approach to establish that ECC system will behave as per design intent during actual LOCA condition. Objective of ECCS Integrated test is to ascertain that various ECC system components operate as intended in design. Additionally, the various system resistances which form the input to LOCA analysis are validated. This test has been carried out by creating actual LOCA during cold and pressurised condition of PHT system to establish all phases of injection with overlap. This paper discusses the results obtained during the Integrated Test and comparison with the prediction during ...
2006-11-13
The long operating cycle simplified boiling water reactor is a reactor concept that pursues both safety and the economy by employing a natural circulation reactor core without a refueling, a passive decay heat removal, and an integrated building for the reactor and turbine. Throughout the entire spectrum of the design basis accident, the reactor core is kept covered by the passive emergency core cooling system. The decay heat is removed by the conventional active low-pressure residual heat removal system. As for a postulated severe accident, the suppression pool water floods the lower part of the reactor pressure vessel (RPV) in the case when core damage occurs, and the in-vessel retention that keeps the melt inside the RPV is achieved by supplying the coolant. The containment adopts a parallel-double-steel-plate structure similar to a hull structure, which contains coolant between the inner and outer walls to absorb the ...
2003-07-15
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
International Nuclear Information System (INIS)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel ...
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
Energy Technology Data Exchange (ETDEWEB)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel ...
2007-03-15
Energy Technology Data Exchange (ETDEWEB)
Certification as applied to existing computer codes includes the verification and validation process, placing the code in configuration control, establishing user qualification standards and training requirements. All software intended for use in critical calculations must be certified. This report is intended to fulfill the requirements for the certification of the SHIELD, SHLDED, GEDIT, GENPRT, FIPROD, FPCALC, and PROCES modules of the SHIELD system built February, 1992, by W.S. Parks. These modules are used for burnup, cooling, separate, and edit calculations.
1992-02-01
Primary side flow distribution of a horizontal steam generator under low flow conditions
Energy Technology Data Exchange (ETDEWEB)
The presentation deals with the flows on the primary side of a horizontal steam generator under conditions typical to natural circulation cooling of the reactor. The main goal is to analyse the effect of primary flow patterns on the heat transfer capability of the steam generator. Conclusions pertinent to steam generator modelling with system codes are also drawn. (10 refs., 9 figs., 4 tabs.).
1993-12-31
Primary side flow distribution of a horizontal steam generator under low flow conditions
International Nuclear Information System (INIS)
The presentation deals with the flows on the primary side of a horizontal steam generator under conditions typical to natural circulation cooling of the reactor. The main goal is to analyse the effect of primary flow patterns on the heat transfer capability of the steam generator. Conclusions pertinent to steam generator modelling with system codes are also drawn. (10 refs., 9 figs., 4 tabs.).
1992-09-29
New safety device announced for nuclear power plants
International Nuclear Information System (INIS)
An Ottawa-based company, ECS-Power Systems Inc., has successfully completed a series of tests on an innovative device called a hydrodynamic port (HDP), which makes it possible to automatically initiate and maintain emergency cooling of a nuclear reactor core by natural processes, without relying in any way on human intervention, instrumentation, electric power, valves or moving parts of any kind.
Improved FNAL linac beam choppers
Energy Technology Data Exchange (ETDEWEB)
A discussion is presented of the 750-KeV chopper experience with both proton and negative ion beams and the ability of these systems to tailor the Linac beam to the diverse requirements of its users; normal accelerator injection, neutron therapy beam, and electron cooling experiments. This flexibility plus a cleaner beam pulse, improved thyratron operation, and mechanical modularity are the results of recent improvements. Additional benefits have been increased reliability and ease of service to the 750-KeV chopper. 3 refs.
1981-06-01
Growth model and on-line measurement of pitting corrosion on carbon steel
Energy Technology Data Exchange (ETDEWEB)
A growth model of pitting corrosion of carbon steel in cooling water systems was developed on microscopic observations of pits and electrochemical studies. Results of pitting corrosion measurements in laboratory and field conditions with the model, using a newly developed electrochemical device, are discussed. For an actual heat exchanger up to a year operation, the values of pitting depth estimated were in good agreement with the measured values.
1996-12-01
Tabulated data are presented from air monitoring studies in the vicinity of the Chalk Point fossil-fuel power plant located in a coastal region of Maryland. (ERA citation 02:057363)
1977-01-01
100 Areas: (For Technical Progress Letter No. 97), May 7--13
Physics information for the D and F piles is presented. Thermal conductivity, reactivity, and irradiation levels are included. Concerning the cooling systems: process water control, pressure drip studies, purging studies, corrosion, and gun barrel clearance of expanded graphite are discussed. (GHH)
1946-05-17
Status of combined point source search with neutrino telescopes IceCube and AMANDA
Energy Technology Data Exchange (ETDEWEB)
In this talk, we summarize recent results obtained from the combined neutrino telescopes IceCube and AMANDA. The combined approach, including data taken from both detectors simultaneously, is compared to other analyses that are using IceCube only data. The main benefit of the combined detector is its improved performance at low energies, meaning energies below 1 TeV (close to the energy threshold of the detector). The discussion is focused on the search for extra-terrestrial neutrinos from candidate sources in our Galaxy. Using appropriate cuts, the sensitivity can be optimized for soft spectra neutrino sources. With the resulting data sample, several studies are performed: an unbinned Galactic Plane Scan and a Cygnus region analysis: the Multi Point Source analysis. The current status of these analyses is presented.
2010-07-01
British Library Electronic Table of Contents (United Kingdom)
A novel PCR based assay was devised to specifically detect contamination of any Salmonella serovar in milk, fruit juice and ice-cream without pre-enrichment. This method utilizes primers against hilA gene which is conserved in all Salmonella serovars and absent from the close relatives of Salmonella. An optimized protocol, in terms time and money, is provided for the reduction of PCR contaminants from milk, ice-cream and juice through the use of routine laboratory chemicals. The simplicity, efficiency (time taken 3-4 h) and sensitivity (to about 5-10 CFU/ml) of this technique confers a unique advantage over other previously used time consuming detection techniques. This technique does not involve pre-enrichment of the samples or extensive sample processing, which was a pre-requisite in mos...
2012-01-01
1991 ice jamming along the Saint John River: a case study
Energy Technology Data Exchange (ETDEWEB)
Field investigations of major and damaging ice jamming on the Saint John River at Dickey, Maine , and at Sainte-Anne de-Madawaska, New Brunswick, in 1991, were described. The investigations included measurement of water surface profiles and shear wall heights at both sites. The measurements were supplemented by information from local observers and data collection agencies. Using a simplified equilibrium analysis, ice jam thickness and water level at the Dickey site was found to be generally in agreement with observed values. At Sainte-Anne-de-Madawaska sufficient data was obtained to construct and calibrate the numerical model RIVJAM which determined the configuration of the jam in nonequilibrium reaches. Use of the model enabled the successful reproduction of a measured water profile along the jam and the prediction of the approximate thickness of the jam, which was generally less than the measured shear wall height. 14 refs., 11 figs.
1996-04-01
Energy Technology Data Exchange (ETDEWEB)
A thermohydraulic study of MTR fuel element is presented as a basic requirement for the development of an irradiation facility for testing fuel elements. A computer code named 'Thermo' has been developed for this purpose, which can stimulate different working conditions, such as, cooling, power elements and neutron flux, performing all pertinent thermohydraulic calculations. Thermocouples were used to measure the temperature gradients of the cooling fluid throughout the IEAR-1 reactor core. All experimental data are in good agreement with the theoretical model applied in this work. Finally, a draft of the proposed facility and its safety system is presented. (author)
1980-07-01
Averting problems caused by solutions
International Nuclear Information System (INIS)
A brief overview is given of a report on Emergency Core Cooling Systems (ECCS) Recirculation Reliability Knowledge Base compiled by the International Working Group on ECCS Reliability for the OECD/NEA/CSNI. Four safety issues are identified which arise in the context of loss of coolant accidents (LOCAs) and are connected with materials and/or processes that interfere with the ECCS safety function in ways other than just strainer head loss generation. They are: the generation of missiles during a LOCA from encapsulated insulation materials used to reduce insulation debris production; clogging of BWR pressure suppression containment vent pipes by insulation jackets or metallic insulation foil pieces; strainer or sump debris ingestion and the effects of ingested debris on ECCS equipment and core cooling; miscellaneous items such as material aging and self-cleaning strainer concepts. The emphasis is mainly on BWRs but many of ...
A He-gas Cooled, Stationary Granular Target
In the CERN approach to the design of a neutrino factory, the repetition frequency of the proton beam is high enough to consider stationary solid targets as a viable solution for multi-MW beams. The target consists of high density tantalum spheres of 2 mm diameter which can efficiently be cooled by passing a high mass flow He-gas stream through the voids between the Ta-granules. Very small thermal shocks and stresses will arise in this fine grained structure due to the relatively long burst of 3.3 ms from the SPL-proton linac. In a quadruple target system where each target receives only one quarter of the total beam power of 4 MW, conservative temperature levels and adequate lifetimes of the target are estimated in its very high radiation environment. A conceptual design of the integration of the target into the magnetic horn-pion-collector is presented.
2003-01-01
Screening Criteria for Loss of Room Cooling Failure
Energy Technology Data Exchange (ETDEWEB)
In this report, we estimated the temperature of the pump rooms and reviewed the operability of the components under the loss of the HVAC (Heating, Ventilation, and Air Condition) system. The issues relevant to the HVAC system in the PSA (Probabilistic Safety Assessment) FT (Fault Tree) model are as follows: (1) Does the loss of the HVAC system bring about a function failure of other components? (2) Can the operator take action to reduce the temperature of the room in case of a HVAC function failure? At present, we do not know whether a component will lose its function or not under the loss of the HVAC. ASME Standard describes that a recovery action can be credited if the related recovery action is included in the procedure or there are similar recovery experiences in the plant. However, there is no description about the recovery action of the HVAC in the EOP (Emergency Operation Procedure) of the UCN3, 4 under the situation ...
2007-01-15
Simulation of electromechanical and thermomechanical loads on first wall mock-ups
International Nuclear Information System (INIS)
In order to study the boundary conditions for the occurrence of ratcheting, a testing rig was erected. In this rig, small-scale mock-ups of the first wall were tested under mechanical conditions similar to those expected during disruptions. These mock-ups were made of stainless steel AISI 316. They were heated on the surface and water cooled from inside. Disruption forces were simulated by a high-speed hydraulic bending system by impact loads. The mock-ups were heated by a high-frequency generator and cooled by water through two cooling channels.In addition to the experimental work, simplified analytical analysis and numerical calculations were carried out using the finite element program ABAQUS. In these calculations, the temperature and stress fields in the mock-ups were investigated and the influence of the different constitutive equations was studied.The experimental results confirm the ratcheting ...
Management of pitfalls for the successful clinical use of hypothermia treatment.
Therapeutic hypothermia is a promising method for controlling intracranial pressure (ICP) in severely brain-injured patients. However, clinical data regarding the effect of brain hypothermia on overall outcome of these patients is limited. This may be because there are specific pitfalls associated with the clinical management of induced hypothermia in patients with severe traumatic brain injury (TBI). These pitfalls may be avoided by preventing specific risk factors when cooling is induced and with rewarming. However, these risk factors have not been well systematically discussed in the literature. In this paper, three categories of clinical issues regarding the management of brain hypothermia are discussed: (1) stress-induced secondary brain injury mechanisms; (2) technical aspects of intensive care unit (ICU) cooling management; and (3) rewarming rates and methods. For patients with a Glasgow Coma Scale (GCS) score of less than 8, management ...
2009-03-01
International Nuclear Information System (INIS)
In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and ...
Flight Performance of the AKARI Cryogenic System
We describe the flight performance of the cryogenic system of the infrared astronomical satellite AKARI, which was successfully launched on 2006 February 21 (UT). AKARI carries a 68.5 cm telescope together with two focal plane instruments, Infrared Cameras (IRC) and Far Infrared Surveyor (FIS), all of which are cooled down to cryogenic temperature to achieve superior sensitivity. The AKARI cryogenic system is a unique hybrid system, which consists of cryogen (liquid helium) and mechanical coolers (2-stage Stirling coolers). With the help of the mechanical coolers, 179 L (26.0 kg) of super-fluid liquid helium can keep the instruments cryogenically cooled for more than 500 days. The on-orbit performance of the AKARI cryogenics is consistent with the design and pre-flight test, and the boil-off gas flow rate is as small as 0.32 mg/s. We observed the increase of the major axis of the ...
2007-01-01
Braking system for use with an arbor of a microscope
International Nuclear Information System (INIS)
A balanced braking system comprising a plurality of braking assemblies located about a member to be braked. Each of the braking assemblies consists of a spring biased piston of a first material fitted into a body of a different material which has a greater contraction upon cooling than the piston material. The piston is provided with a recessed head portion over which is positioned a diaphragm and forming a space therebetween to which is connected a pressurized fluid supply. The diaphragm is controlled by the fluid in the space to contact or withdraw from the member to be braked. A cooling device causes the body within which the piston is fitted to contract more than the piston, producing a tight shrink fit therebetween. The braking system is particularly applicable for selectively braking an arbor of an electron microscope which immobilizes, for example, a vertically adjustable low temperature specimen ...
The thermal response of an infinite line of open loop wells for ground coupled heat pump systems
British Library Electronic Table of Contents (United Kingdom)
Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...
2011-01-01
Proliferation resistant fission energy systems
Energy Technology Data Exchange (ETDEWEB)
Fission energy systems that significantly reduce the need for the user country to be involved in the nuclear operations and technology could simplify implementation and reduce the proliferation potential. Conceptual system designs with improved (relative to the once-through LWR fuel cycle) proliferation resistance for application in developing countries are being evaluated. The fission energy systems being studied include all activities and equipment necessary to produce energy, recycle selected materials, and dispose of the waste. The systems currently being studied are required to function with no refueling of the reactors on the user site. These requirements are being used to initiate the study, on the assumption that removal of these operations from within the developing countries will improve the proliferation resistance. Preliminary evaluations of a small fast reactor core ...
1997-07-02
New monitoring system for microbiological control effectiveness on pitting corrosion of carbon steel
Energy Technology Data Exchange (ETDEWEB)
A new on-line monitoring system has been developed for pitting corrosion monitoring of carbon steel tubes in cooling water systems. This monitoring system was found to be quite sensitive to the microbiological activity relating to pitting corrosion on a real-time basis. The value of galvanic current indicates the performance level of pitting corrosion inhibition even in biocide application. In addition, the changes in the galvanic current provide indicative information about the effectiveness in microbiological control program, even when the pressure drop measurement indicates no biofilm formation. It can be also useful in detecting a microbiological control upset. In this paper, an introduction of the new monitoring system as a microbiological control effectiveness monitor and the field test results are discussed.
1997-12-01
Energy Technology Data Exchange (ETDEWEB)
Recently it is strongly required to reduce energy consumption to cope with the global warming. Since energy consumption in commercial and residential sectors are increasing while industrial sector is almost constant in Japan, policies to lead energy conservation in urban areas is quite important. This study aims at investigating the performance of urban energy systems which install combined heat and power (CHP) as a district heating and cooling (DHC) plant and the influence of CHP on the structure of electric power systems of utilities. The behavior of energy technologies and the possibility of energy conservation are evaluated based on an optimization model with respect to total system cost. Sensitivity analysis of population allocation into urban areas indicates that fossil fuel consumption varies in the range of 10--20% compared with conventional systems.
1997-12-31
Safe conditions for contacting nitric acid or nitrates with tri-n-butyl phosphate (TBP)
Energy Technology Data Exchange (ETDEWEB)
In response to a request from DOE-SR, the current state of knowledge of the reactions between TBP and aqueous nitrate solutions is critically reviewed, and recommendations are made for the safe operation of SRS separations equipment in which this combination of chemicals may be present. The existing limits for evaporation are validated. Guidelines are presented for cases in which general limits do not apply. The rate of reaction between nitric acid and TBP appears to be controlled by the rate of TBP hydrolysis. The hydrolysis reaction produces dibutyl phosphate and n-butanol. The hydrolysis rate is a strong function of temperature, and becomes very fast at temperatures in the range 130{degrees} to 150{degrees}C. The resulting n-butanol is volatile at high temperatures, boiling at 117.5{degrees}C, but is also subject to exothermic oxidation by nitric acid or nitrates. If oxidation occurs before the n-butanol evaporates, the heat of oxidation may exceed local cooling ...
1994-01-01
International Nuclear Information System (INIS)
The commercial Modular High Temperature Gas-Cooled Reactor (MHTGR) achieves improved reactor safety performance and reliability by utilizing an integrated sequence of completely passive thermal storage and heat transfer mechanisms to reject decay heat in the event that all its active cooling systems fail to operate. During such events, the initial heatup transient in the core is followed by a quasi-steady state cooldown process which, if uninterrupted, can continue for several days. A buoyancy-driven natural convection cooling system called the RCCS facilitates the continuous heat removal by circulating ambient air through the reactor cavity, where it is heated and then exhausted to the outside environment. The peak thermal load on the RCCS occurs approximately at the time that the vessel reaches its highest temperature. To confirm the adequacy of the RCCS design, detailed ...
1994-08-01
Ground- and space-based temperature and humidity retrievals: Statistical evaluation
Energy Technology Data Exchange (ETDEWEB)
A near-real-time integrated temperature and water vapor sounding system has been designed and in operation since June 1993. It combines hourly data from the ground-based radio acoustic sounding system (RASS), a two-channel microwave radiometer, standard surface meteorological instruments, a lidar ceilometer, and the Aerodynamic Research Incorporated Communication, Addressing and Reporting System aboard commercial airlines with space-based data from the TIROS-N Operational Vertical Sounder (TOVS). The physical retrieval algorithm provided by the International TOVS Processing Package is used for combining the ground- and space-based temperature and humidity profiles. The first-guess profiles of temperature and humidity required by the physical retrieval algorithm are obtained by using a statistical inversion technique and the ground-based remote sensors measurements. Statistical error estimates are presented for the hourly, ...
1996-03-01
FPSOs assuming key role in harsh environments
Energy Technology Data Exchange (ETDEWEB)
There are at present 116 floating production systems and 60 storage vessels dotting the oceans involved in hydrocarbon exploration and production activities. Although concentrated mostly in the North Sea, they can be found also off the coast of Australia, eastern Canada, Brazil, some African nations and the Gulf of Mexico. They range from converted tankers to purpose built rigs. The most adaptable of the various systems is the floating production, storage and offloading (FPSO) vessel, first developed as a cost-effective means of developing fields in Brazil's very deep offshore areas. Still being tested and modified for work in widely different environments, FPSOs appear to have met all requirements in producing expenditure efficiencies, maximizing profits, and protecting workers. One of the most efficient and most technically advanced is a 292-metre long FPSO built for the Terra Nova Alliance by Daewoo Shipyards in South Korea. It ...
2001-01-22
Process for removing sulfur dioxide from gas streams
In the prevention of atmospheric pollution by sulfur dioxide emissions from acid absorbers in contact process sulfuric acid plants in which the unconverted SO/sub 2/ is accumulated by adsorption in a zeolite adsorbent bed and desorbed back into the acid production system, it is found that ambient moist air, after partial dehydration in an acid scrubber is suitably used both to cool down and hot purge desorb the zeolite beds. In addition the pure water derived from the ambient air is advantageously used in the acid-making system.
1976-10-26
Freeze protection valve and system
Energy Technology Data Exchange (ETDEWEB)
The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.
1985-12-10
Flooded Underground Coal Mines: A Significant Source of Inexpensive Geothermal Energy
Energy Technology Data Exchange (ETDEWEB)
Many mining regions in the United States contain extensive areas of flooded underground mines. The water within these mines represents a significant and widespread opportunity for extracting low-grade, geothermal energy. Based on current energy prices, geothermal heat pump systems using mine water could reduce the annual costs for heating to over 70 percent compared to conventional heating methods (natural gas or heating oil). These same systems could reduce annual cooling costs by up to 50 percent over standard air conditioning in many areas of the country. (Formatted full-text version is released by permission of publisher)
2007-04-01
Energy conservation by means of integrated systems; Beter resultaat door klimaatkwartet
Energy Technology Data Exchange (ETDEWEB)
Air conditioning is getting maximum attention these days when building new offices. For the new office building of the assurance company Zwitserleven in Amstelveen, Netherlands, a new air conditioning concept is applied, based on four existing air conditioning methods: cold storage and heat storage in the soil, heat pump, double-wall facades with integrated climate control, and radiant heating combined with a cooling system in the ceiling. The integration of these methods not only provides complete climate comfort for the employees but also substantial energy savings. 3 figs.,1 ills.
1995-11-01
Application of neutron radiography to a diagnosis of refrigerator
International Nuclear Information System (INIS)
A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).
1996-07-01
Waiting For Lift-off Cake - NASA
1 yellow cake mix 1 container star sprinkles 1 box of regular ice cream cones 2 vanilla frosting containers 1 box Teddy Grahams Green food coloring ...
User Manual for the NASA Glenn Ice Accretion Code ... - GLTRS - NASA
eling of the Stefan Problem, AIAA J., vol. 22, Nov. 1984, pp. 1685-1690. Schlichting, H., Boundary-Layer Theory. F. J. Cerra, ED. ...
Temperature profiles and bathymetry of some high mountain lakes
UK PubMed Central (United Kingdom)
The ice cover in high mountain lakes breaks up and disappears in about an hour, in part because it has been divided into fragile vertical spindles, which are individual crystals. Contributing to this...Full Text Available
2000-06-06
Pseudocraters as indicators of ground ice on Mars
International Nuclear Information System (INIS)
Positive identification of Martian pseudocraters would be a strong indication of past occurrence of ice at or near the surface of Mars. The basis for suggesting that small cones on Mars are pseudocraters includes: (1) small size, (2) abundant but patchy distribution on what appear to be volcanic plains, (3) presence of other features suggestive of surface or subsurface ice, (4) morphological similarities to Icelandic pseudocraters, and (5) the similarity in distribution of crater/cone diameter ratios to Icelandic pseudocraters. This last morphometric parameter may be the most important, since other possible small terrestrial volcanic analogs have very different crater/cone diameter ratio distributions. In a survey of the available high resolution Viking Orbiter imagery, abundant fields of possible pseudocraters were found. However, only a small fraction of the plains forming units imaged at high resolution were found to contain the small cones. ...
1987-05-01
Intracardiac Echocardiography: A New Guiding Tool for Transcatheter Aortic Valve Replacement
British Library Electronic Table of Contents (United Kingdom)
BackgroundEchocardiography has been debated as an adjunct for transcatheter aortic valve replacement (TAVR). The aim of this prospective study was to comparatively evaluate intraprocedural guidance using intracardiac echocardiography (ICE) and transesophageal echocardiography (TEE). MethodsFifty high-risk patients with severe aortic stenosis scheduled for TAVR were randomized to either guidance using ICE (group 1; n = 25) or monitoring using TEE (group 2; n = 25). ResultsIn contrast to TEE, ICE allowed continuous monitoring. The need for probe repositioning during the procedure was much lower in group 1 (0.1 +- 0.3 vs 5.7 +- 0.7 maneuvers, P P = .003). Both coronary ostia were more frequently visualized in group 1 (18 vs 2 cases, P n = 25, r2 = 0.90, P n = 11, P = .012), but ICE did not (m...
2011-01-01
Implications of abrupt climate change.
UK PubMed Central (United Kingdom)
Records of past climates contained in ice cores, ocean sediments, and other archives show that large, abrupt, widespread climate changes have occurred repeatedly in the past. These changes were especially...Full Text Available
2004-01-01
Ice engineering advances : their impact on development concepts
Energy Technology Data Exchange (ETDEWEB)
The Hebron offshore drilling project in Atlantic Canada was discontinued in 2002 due to economic challenges. Chevron-Texaco has conducted small-scale studies to find ways to improve the project's viability. One of the main challenges facing this offshore drilling project is the issue of iceberg scour and its effect on seafloor equipment. This paper demonstrates how advances in ice engineering have resulted in new and cost-effective development concepts for: central gravity base structures; wellhead gravity base structures; floating production, storage and offloading (FPSO) subsea facilities; and, long subsea tieback and trench optimization. New studies have provided a better understanding of ice contact pressures, drift velocities, iceberg management and interaction processes. New designs for gravity base structures can reduce wave loads. The selection of a new development concept is determined by economic viability, capital cost, ...
2004-07-01
Frequently Asked ... - Precipitation Measurement Missions - NASA
... say for sure if the signal is coming from hail, lots of graupel, or some other hydrometeor . ... Precipitation forms when cloud droplets or ice particles in clouds grow and .... A landslide is the movement of rock, debris, or earth down a slope. ...
Characterization of MJO ... - Microwave Limb Sounder (MLS) - NASA
Feb 15, 2008 ... hydrological properties (e.g., hydrometeor budgets, cloud ice/water, transports ... cloud fraction, mass and particle size. In combination, these .... anomaly in the LS is not simply due isentropic movement of water vapor relative ...
UK PubMed Central (United Kingdom)
Bacteria and fungi are ubiquitous in the atmosphere. The diversity and abundance of airborne microbes may be strongly influenced by atmospheric conditions or even influence atmospheric conditions themselves...Full Text Available
2009-08-01
properties such as effective particle size, thermody- namic phase (water, ice), cloud-top properties ...... Green, R.O., and J.E. Conel, 1995: Movement of ..... vertical hydrometeor profiles from passive micro- wave sensors. IEEE Trans. ...
Design and performance of a solar-powered air-conditioning system in a green building
Energy Technology Data Exchange (ETDEWEB)
A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m{sup 2} solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on performance characteristics of the adsorption chiller, the operation mode of the solar-powered air-conditioning system was optimized by maintaining a phase shift of 540 s between the two adsorption chillers. Thereafter, the whole system realized stable operation by the balance of heat consumption and refrigeration output. From June to August of 2005, the solar-powered air-conditioning system continuously ran between 9:00 and 17:00. The operation performance of the system under representative working condition showed that the average refrigeration output of the solar-powered ...
2008-05-15
Data Center Energy Benchmarking: Part 3 - Case Study on an ITEquipment-testing Center (No. 20)
Energy Technology Data Exchange (ETDEWEB)
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center ...
2007-07-01
MR-6 Type Fuel Elements Cooling in Natural Convection Conditions after Reactor Shutdown
International Nuclear Information System (INIS)
... Natural convection cooling of the channel type reactor performed with the fuel
1992-08-03
Design and performance tests of flap value for HANARO natural circulation cooling
International Nuclear Information System (INIS)
... [2] Hee Taek Chae, et al., "On the Natural Convection Cooling in HANARO;
1999-09-06
Energy Technology Data Exchange (ETDEWEB)
The kinetics of HO{sub 2} radicals in UV-irradiated frozen dilute solutions of H{sub 2}O{sub 2} were followed by the ESR technique. Radical disproportionations at the irradiation temperature were found to be adequately described in terms of dispersive kinetics by a second-order equal-concentration kinetic equation with rate parameters changing non-monotonically in the temperature range 100-200 K. These changes are thought to occur due to well separated structural relaxation regions of polycrystalline ice in the above temperature range. (author).
1994-11-01
International Nuclear Information System (INIS)
The Four years of the IMPACT, 'Integrated Modular Plant Analysis and Computing Technology', project Phase 1 have been completed. The verification study of Severe Accident Analysis Code SAMPSON prototype developed in Phase 1 was conducted in two steps. First, each analysis module was run independently and analysis results were compared and verified against separate-effect test data with good results. Second, with the Simulation Supervisory System, up to 11 analysis modules were executed concurrently in the parallel environment (currently, NUPEC uses IBM-SP2 with 72 process elements), to demonstrate the code capability and integrity. The target plant was Surry as a typical PWR and the initiation events were a 10-inch cold leg failure. The analysis is divided to two cases; one is in-vessel retention analysis when the gap cooling is effective (In-vessel scenario test), the other is analysis of phenomena event is extended to ex-vessel due to the ...
1999-07-01
Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar delivery efficiency of the Corning collector ranged from 49% to 60% of the incident solar energy. The portion of the space ...
1979-01-01
Fast breeder reactor safety : a perspective
International Nuclear Information System (INIS)
Taking into consideration India's limited reserves of natural and vast reserves of thorium, the fast reactor route holds a great promise for India's energy supply in future. The fast reactor fueled with "2"3"9Pu/"2"3"8U (unused or depleted) produces (breeds) more fissionable fuel material "2"3"9Pu than it consumes. Calculations show that a fast breeder reactor (FBR) increases energy potential of natural uranium by about 60 times. As the fast reactor can also convert "2"3"2Th into "2"3"3U which is a fissionable material, it can make India's thorium reserves a source of almost inexhaustible energy supply for a long time to come. Significant advantage of FBR plants cooled by sodium and their world-wide operating experience are reviewed. There are two main safety issues of FBR, one nuclear and the other non-nuclear. The nuclear issue concerns core disruptive accident and the non-nuclear one concerns the high chemical energy potential of sodium. These two issues are ...
Long pulse chemical laser. Final technical report
Energy Technology Data Exchange (ETDEWEB)
This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation Facility. A Boeing IRAD funded theoretical study on cold cloud ...
1989-02-01
International Nuclear Information System (INIS)
The PANDA test facility at PSI in Switzerland is used to study the long-term Simplified Boiling Water Reactor (SBWRT) Passive Containment Cooling System (PCCS) performance. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and noncondensables in the system. The PANDA facility is in 1:1 vertical scale, and 1:25 'system' scale (volume, power, etc.). Steady-state PCCS condenser performance tests and extensive facility characterization tests have already been conducted. A series of transient system behavior tests have been completed by end of 1995. Results from the first three transient tests (M3 series) are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the SBWR containment is likely to be favorably responsive and highly robust to changes in the thermal ...
Energy Technology Data Exchange (ETDEWEB)
The primary objective of this study was to evaluate the potential environmental effects (both adverse and beneficials) of aquifer thermal energy storage (ATES) technology pertaining to microbial communities indigenous to subsurface environments (i.e., aquifers) and the propagation, movement, and potential release of pathogenic microorganisms (specifically, Legionella) within ATES systems. Seasonal storage of thermal energy in aquifers shows great promise to reduce peak demand; reduce electric utility load problems; contribute to establishing favorable economics for district heating and cooling systems; and reduce pollution from extraction, refining, and combustion of fossil fuels. However, concerns that the widespread implementation of this technology may have adverse effects on biological systems indigeneous to aquifers, as well as help to propagate and release pathogenic organisms that enter thee ...
1988-03-01
Development of fluidized bed cement sintering technology
Energy Technology Data Exchange (ETDEWEB)
In the new system presented in this paper, the cement clinker is sintered, not in a rotary kiln, but in two different furnaces: a spouted bed kiln and a fluidized bed kiln. The heat generated in the process of cooling the cement clinker is recovered by a fluidized bed cooler and a packed bed cooler, which are more efficient than the conventional coolers. Compared with the rotary kiln system, the new technology significantly reduces NO{sub x} emissions, appreciably cuts energy consumption, and reduces CO{sub 2} emissions as well. Thus, the new system is an efficient cement sintering system that is friendly to the global environment. In this paper, we describe this new technology as one of the applied technologies at an industrial level that is being developed in the Clean Coal Technology Project, and we present the results from test operations at our pilot plant.
1994-12-31
Development of a solar thermal storage system suitable for the farmhouse heating in northeast China
Energy Technology Data Exchange (ETDEWEB)
This study reported on the performance of a passive solar radiant floor heating system designed for standard energy-saving farmhouses in northeast China. Weather data in the region was analyzed in terms of solar radiation, temperature, humidity and light levels. The heating characteristics of the building materials such as windows, doors, walls and roofs were also analyzed along with the indoor thermal environment of the farmhouse. The heating load was then calculated along with the size of the thermal storage element and the area of the collector element. The passive solar radiant floor heating system was designed for heating during the winter and cooling in summer. According to the results, the heating characteristics of the system have the potential to improve farming villages environment and the use of renewable energy.
2010-07-01
A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor
Energy Technology Data Exchange (ETDEWEB)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
2002-07-01
A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor
International Nuclear Information System (INIS)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
Data Center Energy Benchmarking: Part 4 - Case Study on aComputer-testing Center (No. 21)
Energy Technology Data Exchange (ETDEWEB)
The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated ...
2007-08-01
FFTF fission gas monitor computer system
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or ...
Guide to Combined Heat and Power Systems for Boiler Owners and Operators
Energy Technology Data Exchange (ETDEWEB)
Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only generate ...
2004-08-19
Energy Technology Data Exchange (ETDEWEB)
The further optimisation and improvement of the efficiency of internal combustion engines require the realisation of new technologies leading to a distinctively faster warm-up behaviour of the coolant and lubricants as well as of the engine components after a cold start. In order to achieve reduced fuel consumption and exhaust gas emissions with the help of heat management, the design criteria of innovative cooling systems need to be reflected and adapted to future requirements. The use of intelligent components within the cooling system, such as the 'Stand Alone Rotary Valve' as a thermostat's substitute or the use of coolant pumps with a rotary valve integrated into the pump's inlet chamber, offer new ways to realise in a decisively quicker and more flexible way the appropriate heating up and cooling down procedures at varying driving ...
2001-07-01
A study of passive and inherent safety design concepts for advanced light= water reactors
Energy Technology Data Exchange (ETDEWEB)
The five thermal-hydraulic concepts chosen for conceptual study of advanced PWR systems have been studied as follows: (1) Critical Heat Flux in passive PWR Conditions: review of previous works (various of correlations, analysis of parametric trends) on CHF, assessment and improvement of CHF prediction models for round tubes, development of the prediction model on bundle CHF with considering the correction factor calculated from the tube data base, design and construction of the intermediate-pressure CHF experimental loop, extension of CHF data base by performing the experiments at low-flow, and low-quality conditions (2) Passive Cooling Concepts for Concrete Containment Systems: Selection of the external condenser by comparing and reviewing between passive cooling concepts for concrete containment system concepts, survey and review of previous studies (theoretical mechanism of ...
1997-07-01
Energy Technology Data Exchange (ETDEWEB)
Geothermal energy pile foundations are an alternative energy source for heating and cooling needs. Utilising this source of energy has great potential due to the environmental, economic and social benefits. This paper looks at an extensive amount of literature on the technology behind the system including the overall process, primary considerations for each of the main components including latest developments as well as design implications such as the integration of ground energy systems into structural piles of buildings. Environmental considerations including performance-dependent parameters of the subsurface are described. Main parameters include thermal conductivity, thermal diffusivity, specific heat capacity and moisture content. Temperature and groundwater effects are also discussed and design considerations are provided. Mathematical models are available to aid in the design of these systems but ...
2010-12-15
High quality water supply system; Joshitsusui kyokyu system
Energy Technology Data Exchange (ETDEWEB)
This paper, firstly, introduces the background in developing a high quality water supply system, in which the drinking water system is isolated inside a building. Results of questionnaire on the high quality service water are illustrated. The results of questionnaire have revealed that the high quality service water is extremely interested. Then, are described the target quality of high quality water, the constitution of high quality water supply system, the treatment process, the measures to secure safety and sanitary, and the method of maintenance. The high quality water is produced through the activated charcoal absorption treatment, membrane treatment, ozonation, cooling, mineral addition, and disinfection of city water. Furthermore, application examples of this system adopted to a department store and a bachelor apartment house are introduced. For the high quality water supply ...
1995-01-15
International Nuclear Information System (INIS)
Norway is a member of Annex 29, 'Ground-Source Heat Pump Systems Overcoming Technical and Market Barriers' (2004-2006), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 7 participating countries are Austria (Operating Agent), Canada, Japan, Norway, Spain, Sweden and the USA. The Norwegian participation is financed by ENOVA SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. This report provides a status for ground-source heat pump (GSHP) systems in Norway with regard to state-of-the-art technology, installation examples, geological data, costs and market opportunities. A Norwegian Internet home page for ground-source heat pump systems (www.energy.sintef.no/prosjekt/Annex29) is also presented. GSHP systems in Norway are classified as direct systems (groundwater and ...
International Nuclear Information System (INIS)
In General Electric's design of the Simplified Boiling Water Reactor (SBWR), The depressurization valves (DPV) are installed in the reactor pressure boundary: four are connected to the reactor vessel by means of nozzles, and two more are located on the main steam pipes (one DPV for each line), which act during particular transients and/or loss of coolant accidents (LOCA), consequently providing the reactor vessel with a safe quick depressurization system. Once the vessel is de pressurised, the passive gravity-driven cooling system (GDCS) starts to operate, permitting the injection of water required for continuous core cooling. DPVs are leak tight, with welded flaps, actuated by a [striker[hammer***] which is activated by an explosive mixture. The dynamic loads that open these valves include, in addition to those produced by steam (typical in any thermodynamic transient with open/close valves), other ...
International Nuclear Information System (INIS)
The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis was done for the ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is strongly affected by the ...
2004-05-01
International Nuclear Information System (INIS)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is strongly affected by the ...
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
An experimental investigation of a humidification-dehumidification desalination (HDD) process using solar energy at the weather conditions of Suez City, Egypt, is presented. A test rig is designed and constructed to conduct this investigation under different environmental and operating conditions. The test rig consists of a solar water heater (concentrator solar collector type), solar air heater (flat plate solar collector type), humidifier tower and dehumidifier exchanger. Different variables are examined including the feed water flow rate, the air flow rate, the cooling water flow rate in the dehumidifier and the weather conditions. Comparisons between the experimental results and other published results are presented. It is found that the results of the developed mathematical model by the same authors are in good agreement with the experimental results. The tested results show that the productivity of the system is strongly affected by the ...
2004-05-01
Loss of flow incident - Simulation and measurements in the MPR
International Nuclear Information System (INIS)
As part of the Probabilistic Safety Analysis of the Multi Purpose Reactor, MPR, the list of Postulated Initiating Events was analyzed and one of these PIEs corresponds to the Loss of Coolant Flow. It is well known that during the operation life of a research reactor a LOFA could eventually occur and, once this event takes place, in time detection and automatic actions, thanks to the engineering safety features of the system, will mitigate the incident evolution. The postulated event corresponds to a loss of flow due to a total loss of power supply. The goal of the present work is to provide a general description and the engineering safety features of the MPR, as well as describe the sequence of scenarios during a LOFA. Temporal evolution of main parameters is presented, also. During Stage A of the Commissioning Program measurements of the core cooling system pump coast-down were performed in order to validate previous ...
1999-10-26
The PANDA facility and first test results
International Nuclear Information System (INIS)
The PANDA test facility at the Paul Scherrer Institute is used to study the long-term performance of the Simplified Boiling Water Reactor's passive containment cooling system. The PANDA tests demonstrate performance on a larger scale than previous tests and examine the effects of any non-uniform spatial distributions of steam and non-condensable gases in the system. The facility is in 1:1 vertical scale and 1:25 scale for volume, power etc. Extensive facility characterization tests and steady-state passive containment condenser performance tests are presented. The results of the base case test of a series of transient system behaviour tests are reviewed. The first PANDA tests exhibited reproducibility, and indicated that the Simplified Boiling Water Reactor's containment is likely to be favorably responsive and highly robust to changes in the thermal transport patterns. (orig.).
Reflux boiling heat removal in a scaled TMI-2 system test facility
International Nuclear Information System (INIS)
An investigation of decay heat removal by the reflux boiling process was performed on a 1/18 linear-scaled test facility simulating the Three Mile Island (TMI-2) primary system. The objective was to clarify reflux boiling phenomena and core cooling effectiveness. Principal test variables included: core power, primary system water and gas inventories, and steam generator secondary-side coolant flow rate. Of 49 tests conducted, 43 achieved a steady-state heat rejection mode within 3 hours. Subsequent analyses identified two distinct reflux boiling modes. Based upon our current understanding, reflux boiling appears to be an effective process for removing decay heat in a broad range of the conditions investigated for a plant of the TMI configuration.
1980-06-01
Passive solar design handbooks: Vol III: passive solar design analysis and supplement
Energy Technology Data Exchange (ETDEWEB)
This book applies the Los Alamos Solar Load Ratio (SLR) method to the design of passive solar heating systems, with an emphasis on the average annual heating energy consumption. Recommendations are given on minimizing heating energy consumption by appropriate choices of conservation level and solar system parameters. Analytical methods and supporting tables are presented which enable simple, fast estimates of the heating energy consumption as part of the design process. Topics considered include SLR correlations, the load collector ratio (LCR) method, sensitivity data, cooling considerations, conservation formulas, design procedure, life-cycle costs, high-mass direct gain buildings, low-mass sun-tempered buildings, sunspaces, off-reference night insulation, correlation equations, and mixed systems.
1983-01-01
Modeling and control of a novel heat exchange reactor, the Open Plate Reactor
British Library Electronic Table of Contents (United Kingdom)
A new chemical reactor, the Open Plate Reactor, is being developed by Alfa Laval AB. It combines good mixing with high heat transfer capacity into one operation. With the new concept, highly exothermic reactions can be produced using more concentrated reactants. A nonlinear model of the reactor is derived and a control system is developed. For temperature control a cooling system is designed and experimentally verified, which uses a mid-ranging control structure to increase the operating range of the hydraulic equipment. A Model Predictive Controller is proposed to maximize the conversion under hard input and state constraints. An extended Kalman filter is designed to estimate unmeasured concentrations and parameters. Simulations show that the designed control system gives high conversion ...
2007-01-01
Gas-cooled fast reactor safety - and overview and status of the U.S. program
International Nuclear Information System (INIS)
In the revised GCFR Safety Program Plan a quantitative risk limit line has been adopted to establish requirements for the safety related functions and systems. The risk limit line is derived from an interpretation of NRC established licensing requirements, including those for LMFBR's. Multiple barriers to the progression of accident sequences are defined in the form of six Lines of Protection (LOPs). LOPs-1 to 3 are dedicated to accident prevention and represent the normal operating systems, the dedicated safety systems and the inherent design features, respectively. LOPs-4 to 6 are dedicated to the mitigation of core melt accident consequences and include in-vessel accident containment, secondary containment integrity and radiological attenuation, respectively. Cumulative frequency limits and consequence limits are established for each LOP. Design features associated with each LOP are described and the results of ...
1981-01-01
Five years operating experience at the Fast Flux Test Facility
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...
1987-04-01
Five years operating experience at the Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 ...
1987-09-13
Design and Operation of a Novel Capillary Pumped Two-Loop System for Cooling of Electronic Devices
British Library Electronic Table of Contents (United Kingdom)
Heat pipes, loop heat pipes (LHP), and capillary pumped loops (CPL) have already proven their potential to remove high heat fluxes from a small electronic device and transport the heat to a heat sink that is large enough to transfer it into the ambient air. We introduce a novel two-loop system similar in design to CPLs but with an additional buoyancy-driven fluid loop. Non-degassed methanol is used as a working fluid. Key benefits compared to LHPs and CPLs are easy filling procedure, easy startup, and the tolerance toward noncondensable gases in the fluid. The amount of fluid in the system can be varied over a broad range without affecting the heat transfer performance. Three different inverted-meniscus-type evaporators have been employed in this study. A maximum evaporator heat transfer r...
2012-01-01
International Nuclear Information System (INIS)
Containment is considered as ultimate safety system and is designed to enclose whole reactor system and prevent the spread of active air-borne fission products. For Pressure and Temperature calculation, Design Basis Accident (Dba) is double ended break of reactor inlet header or main steam line break but activity release studies are done to access its performance following limiting design basis accident i.e. Loss of Coolant Accident (LOCA) and Emergency Core Cooling System (ECCS). In such accident scenario, the core is severely damaged and results in production of steam and hydrogen along with release of activity to containment environment. Containment functions are maintained in such accident, and radiological consequences are within the prescribed limits. (author)
2005-12-01
Energy Technology Data Exchange (ETDEWEB)
A burner system particularly useful for downhole deployment includes a tubular combustion chamber unit housed within a tubular coolant jacket assembly. The combustion chamber unit includes a monolithic tube of refractory material whose inner surface defines the combustion zone. A metal reinforcing sleeve surrounds and extends the length of the refractory tube. The inner surface of the coolant jacket assembly and outer surface of the combustion chamber unit are dimensioned so that those surfaces are close to one another in standby condition so that the combustion chamber unit has limited freedom to expand with that expansion being stabilized by the coolant jacket assembly so that compression forces in the refractory tube do not exceed about one-half the safe compressive stress of the material; and the materials of the combustion chamber unit are selected to establish thermal gradient parameters across the combustion chamber unit to maintain the refractory tube in ...
1984-07-10
Application of leak-before-break approach to PWR piping designed by Babcock and Wilcox: Final report
Energy Technology Data Exchange (ETDEWEB)
Recently, the leak-before-break (LBB) concept has been used successfully to eliminate some pipe whip restraints, snubbers and jet impingement shields from the primary reactor cooling system piping of pressurized water reactors. This has resulted in substantial savings in maintenance costs, reductions in radiation exposure of plant service personnel, and has enhanced the overall safety of nuclear power plants. This study provides guidelines to utilities in expanding the application of the LBB concept to additional pipe systems and it couples the concept with hardware optimization. Seven high energy piping systems were investigated for technical feasibility in using the LBB concept. The results indicate that some of these seven lines are good candidates for the leak-before-break application.
1987-01-01
Air pollution abatement at the crossroads. Emissionsminderungstechnik am Scheideweg
Energy Technology Data Exchange (ETDEWEB)
A brief survey of present air pollution abatement requirements relevant to domestic heating systems is followed by a comparative evaluation of the latest results worked out on the part of boiler and burner manufacturers, and the legal requirements and existing regulations. Details are given on the limiting values required by law, the regulations valid for domestic heating systems, and the values fixed according to scientific knowledge and research results (development of NO{sub x} and CO, flame temperature dependence, table comparing CO and NO{sub x} limiting values for different types of burners and boilers). Access is given to primary air pollution abatement measures (cooling of flames, absorber rods, influence of mixing pressure), modern burner and boiler systems, and secondary measures suited for smaller boilers. (HWJ).
1989-05-01
Energy Technology Data Exchange (ETDEWEB)
The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km{sup 2}), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km{sup 2}). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase of summer air ...
2007-10-15
International Nuclear Information System (INIS)
The Siberian Altai covers about 70% of the area of all south Siberian glaciers, which provide fresh water to the upper tributaries of the Ob and Yenisey rivers. The observed air temperature has increased by 1.2 deg. C over northern Eurasia during the last 120 years, affecting the degradation of the Siberian Altai glaciers. In this study, we estimated glacier area changes in the Aktru River basin (44.8 km"2), located in the central Altai mountains. We used the 1952, 1966, 1975 and 2006 remote sensed images with 0.6-3.0 m spatial resolution (aerial photographs, Corona and PRISM satellite images) and differential GPS (DGPS) data. From 1952 to 2006, the total glacier area in the Aktru basin shrank by 7.2% (1.2 km"2). During the last three decades, the rate of glacier area loss increased by a factor of 1.8, thus resembling trends in other mountain systems of Eurasia (Alps, Tien Shan). The glacier area changes were caused mainly by increase of summer air temperature by ...
Atmospheric environmental implications of propulsion systems
Energy Technology Data Exchange (ETDEWEB)
Three independent studies have been conducted for assessing the impact of rocket launches on the earth`s environment. These studies have addressed issues of acid rain in the troposphere, ozone depletion in the stratosphere, toxicity of chemical rocket exhaust products, and the potential impact on global warming from carbon dioxide emissions from rocket launches. Local, regional, and global impact assessments were examined and compared with both natural sources and anthropogenic sources of known atmospheric pollutants with the following conclusions: (1) Neither solid nor liquid rocket launches have a significant impact on the earth`s global environment, and there is no real significant difference between the two. (2) Regional and local atmospheric impacts are more significant than global impacts, but quickly return to normal background conditions within a few hours after launch. And (3) vastly increased space launch activities equivalent to 50 U.S. Space Shuttles or 50 Russian Energia ...
1995-03-01
Energy and exergy analysis of a ground source (geothermal) heat pump system
International Nuclear Information System (INIS)
Ground source heat pumps (GSHPs), often referred to as geothermal heat pumps (GHPs), offer an attractive option for heating and cooling residential and commercial buildings owing to their higher energy efficiency compared with conventional systems. GSHPs have been used for four years in the Turkish market, although they have been in use for more years in developed countries. The purpose of this study is to present an energy and exergy analysis of a GSHP system with a 50 m vertical 1.25 in. nominal diameter U-bend ground heat exchanger. This system was applied to a 65 m"2 room in the Solar Energy Institute, Ege University, Izmir, for the first time at the university level in Turkey. The Institute, built in 1986, has a livable floor area of 3000 m"2 and uses passive solar techniques. The heating and cooling loads of the room studied were 3.8 and 4.2 kW at design conditions, ...
2004-03-01
Tank of sodium cooled fast reactor
International Nuclear Information System (INIS)
Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).
Energy Technology Data Exchange (ETDEWEB)
The possibility of switching the heat transfer consists of varying heat transfer surfaces and making the heat transfer temporarily more intensive. Heat tubes prove to be particularly suitable, which must be exposed to a heat carrier fluid or removed from its effect for switching the heat transfer. This report gives a survey of the possibilities of switching heat flows and for making the heat transfer more intensive. Further, the report contains a survey of patents limited to heat transfer in the fields of cooling internal combustion engines and exhaust systems. (orig.) With 17 figs., 183 refs.
1989-01-01
Conception and design of steam power plants
International Nuclear Information System (INIS)
The manual presents the fundamentals of thermodynamics and fluid mechanics, the main components of steam power plants, and the power generation process. The following concepts and subjects are discussed at length: steam generator; steam turbines; turbogenerators; condensers; cooling technology; water/steam cycle and water treatment; design data of fossil-fuelled power plants; design and optimisation of nuclear power plant thermodynamics; pipelines and fittings; control systems in steam power plants; connection to the electricity grid and self-supply of thermal power plants; power plant transformer concepts and definitions. (HAG).
Breached fuel location in FFTF by delayed neutron monitor triangulation
International Nuclear Information System (INIS)
The purpose of this work was to develop and evaluate a method of locating breached fuel within the Fast Flux Test Facility (FFTF) reactor based on the relative response of the delayed neutron monitors (DNM) located on each of the three primary sodium cooling loops. The primary method of location is the use of tag gas containing unique ratios of the noble gases xenon and krypton. Although the tag gas system works quite well, it is relatively expensive because of the costs of preparing and loading the gas into each fuel pin. Triangulation of DNM signals could potentially decrease tag gas costs while maintaining overall location reliability.
1985-11-10
As an International Organization, one the most important issues that CERN has to respect and guarantee is the protection of the environment. Several of ST activities and operations have a direct impact on the environment: civil engineering works, electrical (transformers) and air-cooling operation, chemical products storage, various waste disposal etc.... Important measures, taken in the past, have to be kept and new ones should be applied in order to insure the conformity of the infrastructure with existing legislation, the correct operation of equipment and systems, the constant monitoring of the different situations and the traceability of the events. Moreover good management of the environment would bring large savings to CERN.
2003-01-01
Solar desalination using humidification dehumidification processes. Pt. 1. A numerical investigation
Energy Technology Data Exchange (ETDEWEB)
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show also that the ...
2004-05-01
Energy Technology Data Exchange (ETDEWEB)
A numerical investigation of a humidification dehumidification desalination (HDD) process using solar energy is presented. The HDD system consists mainly of a concentrating solar water heating collector, flat plate solar air heating collector, humidifying tower and dehumidifying exchanger. Two separate circulating loops constitute the HDD system, the first for heating the feed water and the second for heating air. A mathematical model is developed, simulating the HDD system, to study the influence of the different system configurations, weather and operating conditions on the system productivity. The model validity is examined by comparing the theoretical and experimental results of the same authors. It is found that the results of the developed mathematical model are in good agreement with the experimental results and other published works. The results show also that the ...
2004-05-01
Binary heat pump system. Binary heat pump system
Energy Technology Data Exchange (ETDEWEB)
This technical report describes an outline, features, total energy efficiency, and specifications of binary heat pump system. A closed circuit distributed water heat source heat pump method is employed in the binary heat pump system. Since the circulating water, which is adjusted at a constant temperature, is used as the heat source of the indoor unit, a stable performance can be obtained regardless of outside atmospheric temperature. The binary heat pump system is mainly composed of a center heat pump unit, indoor heat pump unit, heat source water pipes, and circulating pump. The center heat pump unit and the indoor heat pump unit are connected with each other by the heat source water, and each unit can be operated independently. This system is characterized by the simultaneous operation of cooling and heating, high efficiency, high energy saving, high reliability of ...
1993-11-30
Energy Technology Data Exchange (ETDEWEB)
The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the conventional space ...
2010-01-15
Isothermal heat measurements of TBP-nitric acid solutions
Energy Technology Data Exchange (ETDEWEB)
Net heats of reaction were measured in an isothermal calorimeter for both single phase (organic) and two phase (organic and aqueous) TBP/HNO{sub 3} reacting solutions at temperatures above 100 C. The oxidation rate constant was determined to be 5.4E-4 min{sup {minus}1} at 110 C for an open ``vented`` system as compared to 1.33 E-3 min{sup {minus}1} in the closed system. The heat released per unit material oxidized was also reduced. The oxidation in both phases was found to be first order in nitric acid and pseudo-zero order in butylnitrate and water. The hydrolysis (esterification) rate constant determined by Nichols` (1.33E-3 min{sup {minus}1}) fit the experimental data from this work well. Forced evaporation of the volatile components by the product gases from oxidation resulted in a cooling mechanism which more than balanced the heat from the oxidation reaction in the two-phased systems. Rate ...
1994-12-16
Development of an inactive heat removal system for high temperature reactors
International Nuclear Information System (INIS)
Growing public and political interests towards incorporating passive safety features in nuclear installations, let Siempelkamp in late 1987 propose a solution consisting of a prestressed cast-iron pressure vessel and a passive heat removal system, integrated in the reactor cell surrounding the vessel. This solution combines the inherent safety of a prestressed metallic pressure vessel with the advantages of a passive heat removal system and thus constitutes a major step towards the goal of further reducing potential residual risks. The design had to meet the boundary conditions for reactor core and reactor building of the modular 200 MWth pebble bed reactor of Siemens/-KWU. The engineering design showed that many input parameters needed for the finite-element-analysis of the overall structure required a verification by measurements in a well scaled test setup. This was especially required for the heat transfer from the liner of the prestressed ...
1994-08-01
International Nuclear Information System (INIS)
Full text: The transmutation of nuclear waste to reduce the burden on a geological repository is a relevant topic within the Program of Nuclear Safety Research of the Research Centre Karlsruhe. Several studies have confirmed that a high efficiency of transmutation of actinides is reached in fast neutron spectrum reactor system. Therefore, an important effort is dedicated to the study of transmutation strategies with different fast reactors and their associated technologies. Moreover, in international contexts as Generation IV International Forum (GIF) and Sustainable Nuclear Energy Technology Platform (SNETP), fast reactors are considered in the frame of sustainable development of nuclear energy and reduction of waste. The systems that are currently under investigation, in the frame of the different fuel cycle scenarios, are liquid metal cooled and gas cooled fast reactors as well as Accelerator Driven ...
2009-10-05
Development status of Severe Accident Analysis Code SAMPSON
International Nuclear Information System (INIS)
The Four years of the IMPACT, 'Integrated Modular Plant Analysis and Computing Technology' project Phase 1 have been completed. The verification study of Severe Accident Analysis Code SAMPSON prototype developed in Phase 1 was conducted in two steps. First, each analysis module was run independently and analysis results were compared and verified against separate-effect test data with good results. Test data are as follows: CORA-13 (FZK) for the Core Heat-up Module; VI-3 of HI/VI Test (ORNL) for the FP Release from Fuel Module; KROTOS-37 (JRC-ISPRA) for the Molten Core Relocation Module; Water Spread Test (UCSB) for the Debris Spreading Model and Benard's Melting Test for Natural Convection Model in the Debris Cooling Module; Hydrogen Burning Test (NUPEC) for the Ex-Vessel Thermal Hydraulics Module; PREMIX, PM10 (FZK) for the Steam Explosion Module; and SWISS-2 (SNL) for the Debris-Concrete Interaction Module. Second, with the Simulation Supervisory ...
2000-11-01
Accident analysis in research reactors
International Nuclear Information System (INIS)
Full text: Full text: The incomplete understanding of the complex mechanisms connected with the interaction between thermal-hydraulic and neutron kinetics still challenges the design and the operation of nuclear reactors and imposes the adoption of conservatism in the evaluation of safety limits. The recent availability of powerful computer and computational techniques together with the continuing increase in operational experience suggests the revisiting of those areas and the identification of design/operation requirements that can be relaxed. So far, almost all of the safety analyses of research reactors have been performed using conservative computational tools such as channel codes but, nowadays, the application of Best-Estimate (BE) methods constitutes a real necessity. The global aim of the current work is an attempt to apply the best-estimate system thermal-hydraulic code Relap5. For this purpose, the generic IAEA research reactor Benchmark problem is ...
2006-10-15
Turbines for the turn of the century
Energy Technology Data Exchange (ETDEWEB)
This article describes how a natural gas-fired combined cycle with increased firing temperature, reduced cooling air usage, improved component efficiencies, and cycle enhancements could achieve a lower heating value plant efficiency of greater than 60%. Today's gas turbine systems feature high fuel-to-electricity efficiencies. Efficiencies, on a lower-heating-value (LHV) basis, for large natural gas-fired combined-cycle systems for the utility market have been demonstrated at 54%. Even though manufacturers will make improvements in the 1990s, efficiency levels will reach a plateau. Cycle innovations and gas turbine design changes will achieve LHV efficiencies in the 60% range for natural gas-fired utility machines.
1994-06-01
Theoretical and basic experimental analysis on load adjustment of geothermal heat pump systems
Energy Technology Data Exchange (ETDEWEB)
In order to match the output capacity of a geothermal heat pump system (GHPS) with the actual load requirement, research has been conducted in searching for suitable adjusting methods for the GHPS and on the subsequent effects on the working parameters of the GHPS. Firstly, several methods are compared, and it is found that the method of adjusting the compressor's rotation speed using a transducer is better than the others. Secondly, this method is experimented on a small scale GHPS at frequencies ranging from 30 to 55 Hz. The analysis of the experimental data reveals the relationships between the compressor frequency and other important parameters, such as coefficient of performance, heat capacity, cool capacity and compressor power input. The conclusions in the paper can serve as some guidance to the load adjustment of GHPS. (Author)
2003-01-01
Review of SCDAP/RELAP5 Code Application to severe accident analysis of CANDU Reactors
International Nuclear Information System (INIS)
SCDAP/RELAP5 code has been developed in US for best-estimate simulation of light water reactors transients during nuclear accidents. The code models the coupled behaviour of the cooling system, reactor core and fission products release during the accident. It is the result of the coupling between RELAP5, modelling thermal hydraulic, control system, reactor kinetics and the transport of noncondensable gases, and SCDAP code modelling the behaviour of the reactor core during severe accidents. The paper briefly presents the application of SCDAP/RELAP5 code to CANDU severe accident analysis. Also, the paper proposes a summary of the needs for development that could enhance the quality of the severe accidents related predictions in CANDU reactors. (authors)
2009-10-12
Reactor cover gas monitoring at the Fast Flux Test Facility
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-megawatt (thermal) sodium-cooled reactor designed for irradiation testing of fuels, materials and components for LMRs. It is operated by the Westinghouse Hanford Company for the US Department of Energy on the government-owned Hanford reservation near Richland, Washington. The first 100-day operating cycle began in April 1982 and the eighth operating cycle was completed in July 1986. Argon is used as the cover gas for all sodium systems at the plant. A program for cover gas monitoring has been in effect since the start of sodium fill in 1978. The argon is supplied to the FFTF by a liquid argon Dewar System and used without further purification.
1986-09-24
Performance evaluation of low heat rejection engines
Energy Technology Data Exchange (ETDEWEB)
Improving the performance of the Chinese B135 six-cylinder direct injection turbocharged and turbocompounded Low Heat Rejection Engine (LHRE) was based on experimental and analytical studies. The studies were primarily applied on a B1135 single-cylinder LHR engine and a conventional water-cooled B1135 single-cylinder engine. Performance of the B1135 LHRE was worse than that of the conventional B1135 due to a deterioration in the combustion process of the B1135 LHRE. The combustion process was improved and the fuel injection system was redesigned and applied to the B135 six-cylinder LHRE. The new design improved the performance of the LHRE and better fuel economy was realized by the thermal energy recovered from the exhaust gases by the turbocompounding system.
1994-10-01
Investigation of the steady state and transient operating behaviour of a 20 kW pressure electrolyser
Energy Technology Data Exchange (ETDEWEB)
The present paper describes the investigation of the static and dynamic behaviour of an 20 kW pressure electrolyser. The suitability for a coupled operating regime with a wind power plant has been investigated. At first the static behaviour has been analysed. The share of oxygen in hydrogen gas is lower than 0.5 Vol%. But reaching the temperature limit of 80 deg C leads to a switch off of the electrolyser, accompanied by an increase of the oxygen share in hydrogen gas up to 1.3 Vol%. Therefore, an improvement of the cooling system is necessary. Secondly, the electrolyser was excited by different step signals for load changing and finally, the electrolyser has been controlled by the power output signal of the windmill. The investigation shows that the development of a direct coupled wind-hydrogen system will be only a small step. 3 refs.
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
A prototype trumpet type nonimaging secondary concentrator has been designed and fabricated for use with the Cummins Power Generation (CPG) 7.5 kW(e) dish-Stirling system and a preliminary set of operating tests has been carried out. The secondary is 26.7 cm (10.5 in.) deep by about 69 cm (27 in.) wide, and has a geometric concentration of 1.7X. The test units were fabricated from polished copper spinnings, overcoated with vapor deposited aluminum and aluminum oxide layers and are water cooled. The basic design considerations are reviewed, the objectives and test procedures for the experiment are summarized and some preliminary results are presented.
1996-11-01
Energy Technology Data Exchange (ETDEWEB)
A UPS based on a line-interactive system for CATV (Cable TV) networks has been newly developed. An inverter of the UPS featuring a pure sine wave output and equipped with an uninterrupptible transfer switch made it possible to raise its reliability high and to reduce the uninterruptible transfer time from 50 {approx} 100 ms to only 3 ms. The expected life of 15 years and maintenance-free of the UPS were realized by monitoring and optimizing the operational conditions of lead-acid batteries, aluminum electrolytic capacitors and cooling fans. The use of rust- and weather- resistant painting methods for an outer box of the UPS also contributed to extend the life of the system. (author)
1998-12-25
Development and application of a diaphragm micro-pump with piezoelectric device
British Library Electronic Table of Contents (United Kingdom)
In this study, a new type of thin, compact, and light weighed diaphragm micro-pump has been successfully developed to actuate liquid by the vibration of a diaphragm. The micro-diaphragm pump with two valves is fabricated in an aluminum case by using highly accurate CNC machine, and the cross-section dimension is 28?mm??5?mm. Both valves and diaphragm are manufactured from PDMS. The amplitude of vibration by a piezoelectric device produces an oscillating flow and alters the chamber volume by the curvature change of a diaphragm. Several experimental set-ups for performance tests in a single micro-diaphragm pump, isothermal flow open system, and a closed liquid cooling system are designed and implemented. The performance of a one-side actuating micro-diaphragm pump is affected by the design ...
2008-01-01
BR-100 spent fuel shipping cask development
Energy Technology Data Exchange (ETDEWEB)
Continued public acceptance of commercial nuclear power is contingent to a large degree on the US Department of Energy (DOE) establishing an integrated waste management system for spent nuclear fuel. As part of the from-reactor transportation segment of this system, the B W Fuel Company (BWFC) is under contract to the DOE to develop a spent-fuel cask that is compatible with both rail and barge modes of transportation. Innovative design approaches were the keys to achieving a cask design that maximizes payload capacity and cask performance. The result is the BR-100, a 100-ton rail/barge cask with a capacity of 21 PWR or 52 BWR ten-year cooled, intact fuel assemblies. 3 figs.
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
The Berliner Kraft- u. Licht (BEWAG)AG have been conducting investigations during the last several years on a 110 kV low-pressure oil-filled high-power cable with a water cooled conductor and a load capacity of 950 MVA at 110 kV. After successful transport of the cable drums (weight: 16 metric tons; diameter: 4.9 m) from the manufacturing in Cologne, West Germany, to Berlin (West), and after laying of the cable over a 300 m stretch, the commissioning tests in accordance with IEC and VDE* standards have been concluded, and several loadings with a current of 5000 A have been performed. Now, after completion of various improvements in the test system, preparations are underway for initiation of long-term testing over a period of approx. 18 months.
1982-07-01
Energy Technology Data Exchange (ETDEWEB)
The stability of a forced-flow cooled superconducting coil is investigated by use of the numerical simulation. The numerical code to integrate the simultaneous partial differential system composed of the 1 D hydrodynamic equations and the 1 D thermal conduction equation has been developed and stability margins are evaluated as functions of coolant mass flow rate, operation current and imposed magnetic field. The results of computations show that the stability margin is multi-valued with respect to these operation parameters, as expected from the experimental results. It is also shown that the appearance of the first unstable regime is closely related to the existance of the stagnant region located at the upstream side of the heated zone and that the second stable regime appears because the heat transfer is appreciably enhanced by the induced backflow due to the thermal expansion of coolant. 13 refs., 13 figs., 1 tab.
1990-06-25
International Nuclear Information System (INIS)
Purpose: To permit accurate detection of sodium leakage by distinguishing between variations in the overflow tank level due to changes in sodium temperature accompanying changes in the power level or operating state of a liquid metal sodium cooled fast breeder, and a reduction in power level due to duct leakage. Constitution: The volume of sodium in the primary cooling system is roughly estimated from the temperatures of hot and cold legs, and the duct leak preset level with respect to the sodium liquid level within an overflow tank when the plant is normal is varied according to the state of the plant. More particularly, the volume of sodium within the overflow tank is calculated on the basis of a signal representing the liquid level detected by a liquid level gauge in the overflow tank and a signal representing the temperature detected by hot leg and cold leg thermometers, thereby obtaining the preset value of the liquid ...
Opto-acoustic recanilization delivery system
Energy Technology Data Exchange (ETDEWEB)
Fiber delivered laser pulses emulsify thrombus by mechanical stresses that include a combination of pressure, tension and shear stress. Laser radiation is delivered to the locality of a thrombus and the radiation is absorbed by blood, blood dot, or other present materials. The combination of a leading pressure wave and subsequent vapor bubble cause efficient, emulsification of thrombus. Operating the laser in a low average power mode alleviates potential thermal complications. The laser is operated in a high repetition rate mode to take advantage of ultrasound frequency effects of thrombus dissolution as well as to decrease the total procedure time. Specific parameter ranges for operation are described. The device includes optical fibers surrounding a lumen intended for flow of a cooling agent. The fibers may be arranged concentrically around the lumen to deliver radiation and heat over as large an area as possible. An alternative design approach incorporates the ...
2002-01-01
Optimized, Competitive Supercritical-CO_2 Cycle GFR for Gen IV Service
International Nuclear Information System (INIS)
An overall plant design was developed for a gas-cooled fast reactor employing a direct supercritical Brayton power conversion system. The most important findings were that (1) the concept could be capital-cost competitive, but startup fuel cycle costs are penalized by the low core power density, specified in large part to satisfy the goal of significant post-accident passive natural convection cooling; (2) active decay heat removal is preferable as the first line of defense, with passive performance in a backup role; (3) an innovative tube-in-duct fuel assembly, vented to the primary coolant, appears to be practicable; and (4) use of the S-Co2 GFR to support hydrogen production is a synergistic application, since sufficient energy can be recuperated from the product H2 and 02 to allow the electrolysis cell to run 250 C hotter than the reactor coolant, and the water boilers can be used for reactor decay heat removal. ...
Measuring characteristics on emissivity using infrared thermometer for RCCS
International Nuclear Information System (INIS)
In VHTGR (Very High Temperature Gas-cooled Reactor), the radiation plays an important role in heat transfer through the cavity in RCCS (Reactor Cavity Cooling System). We performed the series of experiments to measure the emissivity using the infrared thermometer with wavelength range of 8#approx#14 #mu#m. As the first step, the transmittance of Zinc Selenide (ZnSe) window was measured to estimate the emissivity that can compensate the attenuation effect of window. The kind of gas with various concentrations in the cavity will be released during postulated accidents to the coolant type, so it is essential to estimate the effects of gas on the measurement of emissivity. In this manner we measured the emissivity with the air, the helium and the steam inside chamber. The results represent that the concentration of the air and the helium do not affect the emissivity significantly while the steam decreases the measured ...
2004-12-01
Burnup determination of spent nuclear fuel in the pool
Energy Technology Data Exchange (ETDEWEB)
A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used in determination of the average burnup, cooling time and ...
1998-06-01
Breached fuel location in FFTF by delayed neutron monitor triangulation
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) features a three-loop, sodium-cooled 400 MWt mixed oxide fueled reactor designed for the irradiation testing of fuels and materials for use in liquid metal cooled fast reactors. To establish the ultimate capability of a particular fuel design and thereby generate information that will lead to improvements, many of the fuel irradiations are continued until a loss of cladding integrity (failure) occurs. When the cladding fails, fission gas escapes from the fuel pin and enters the reactor cover gas system. If the cladding failure permits the primary sodium to come in contact with the fuel, recoil fission products can enter the sodium. The presence of recoil fission products in the sodium can be detected by monitoring for the presence of delayed neutrons in the coolant. It is the present philosophy to not operate FFTF when a failure has occurred that permits fission fragments to enter the ...
1985-11-10
Energy Technology Data Exchange (ETDEWEB)
In order to gain a wider knowledge of corrosion phenomena in OFHC (oxygen free high conductivity) copper pipes of the stator cooling circuit of a power plant turboalternator, a research program was laid out which is based on the use of an experimental loop simulating real operating conditions as closely as possible. The samples examined were either copper foils or hollow conductors of the type that is normally used in the stator cooling system, and the circulating fluid was high purity water with controlled O/sub 2/, H/sub 2/ and C0/sub 2/ contents. Investigations were focused on the kinetics of O/sub 2/ removal through catalytic resins covered with metallic palladium (at different temperatures and pressures) and on the kinetics of CO/sub 2/ removal through mixed bed resins. Subsequently, attention was directed to the corrosion of copper (in the form of foils or hollow conductors) under different experimental conditions ...
1991-12-31
An evaluation of the ecological consequences of partial-power operation of the K Reactor, SRS
International Nuclear Information System (INIS)
The K Reactor at the Savannah River Site (SRS) shut-down in spring 1988 for maintenance and safety upgrades. Since that time the receiving stream for thermal effluent, Indian Grave Branch and Pen Branch, have undergone a pattern of post-thermal recovery that is typical of other SRS streams following removal of thermal stress. Divesity of fish and aquatic macroinvertebrate communities has increased and available habitats have been colonized by numerous species of herbaceous and woody plants. K Reactor is scheduled to resume operation in 1991 and operate through 1992 without a cooling tower to cool the discharge. It is likely that the reactor will operate at approximately one-third to one-half of full power (800--1200 MW thermal) during this period and effluent temperatures will be substantially lower than earlier operation at full power. Monthly average discharge temperatures at half-power operation will range from approximately 42 degrees C in ...
Safety significance of ATR passive safety response attributes
International Nuclear Information System (INIS)
The Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory was designed with some passive safety response attributes which contribute to the safety of the facility. The three passive safety attributes being evaluated in the paper are: 1) In-core and in-vessel natural convection cooling, 2) a passive heat sink capability of the ATR primary coolant system (PCS) for the transfer of decay power from the uninsulated piping to the confinement, and 3) gravity feed of emergency coolant makeup. The safety significance of the ATR passive safety response attributes is that the reactor can passively respond to most transients, given a reactor scram, to provide adequate decay power removal and a significant time for operator action should the normal active heat removal systems and their backup systems both fail. The ATR Interim Level 1 Probabilistic Risk Assessment (PRA) models and results were ...
1990-03-01
Performance of a modified two-dimensional gamma scan system in spent fuel pin studies
International Nuclear Information System (INIS)
This work assesses the performance of a modified two-dimensional gamma scan system in spent fuel pin studies. The techniques for a two-dimensional gamma scan studied have been developed at the Hot Cell of Institute of Nuclear Energy Research (INER). Samples are acquired from the spent fuel pin, TPC-SP-C1, which was irradiated in a commercial reactor core (the first of its kind in Taiwan) for 2 years and then deposited in a cooling pool for 10 years. The spent fuel pin was then transferred into INER for further examination. The gamma scanning system was driven by a step motor which had an accuracy within 0.1 mm in both X-Y directions. Data obtained from this system are presented in both an isotopic distribution and contour plot. Results in this study closely correspond to those in other investigations, thereby confirming the effectiveness of this modified system. (author)
1999-11-01
Energy Technology Data Exchange (ETDEWEB)
The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, Sulfur Recovery. This combination of technologies will replace the existing ammonia removal ...
1992-08-24
Innovative coke oven gas cleaning system for retrofit applications
Energy Technology Data Exchange (ETDEWEB)
The coke plant at the Sparrows Point Plant consist of three coke oven batteries and two coal chemical plants. The by-product coke oven gas (COG) consists primarily of hydrogen, methane, carbon monoxide, nitrogen and contaminants consisting of tars, light oils (benzene, toluene, and xylene) hydrogen sulfide, ammonia, water vapor and other hydrocarbons. This raw coke oven gas needs to be cleaned of most of its contaminants before it can be used as a fuel at other operations at the Sparrows Point Plant. In response to environmental concerns, BSC decided to replace much of the existing coke oven gas treatment facilities in the two coal chemical Plants (A and B) with a group of technologies consisting of: Secondary Cooling of the Coke oven Gas; Hydrogen Sulfide Removal; Ammonia Removal; Deacification of Acid Gases Removed; Ammonia Distillation and Destruction; and, Sulfur Recovery. This combination of technologies will replace the existing ammonia removal ...
1992-08-24
Convection heat loss from cavity receiver in parabolic dish solar thermal power system: A review
Energy Technology Data Exchange (ETDEWEB)
The convection heat loss from cavity receiver in parabolic dish solar thermal power system can significantly reduce the efficiency and consequently the cost effectiveness of the system. It is important to assess this heat loss and subsequently improve the thermal performance of the receiver. This paper aims to present a comprehensive review and systematic summarization of the state of the art in the research and progress in this area. The efforts include the convection heat loss mechanism, experimental and numerical investigations on the cavity receivers with varied shapes that have been considered up to date, and the Nusselt number correlations developed for convection heat loss prediction as well as the wind effect. One of the most important features of this paper is that it has covered numerous cavity literatures encountered in various other engineering systems, such as those in electronic cooling ...
2010-08-15
Spin dynamics in Ho{sub 2}Ru{sub 2}O{sub 7}
Energy Technology Data Exchange (ETDEWEB)
The spin relaxation processes within the pyrochlore Ho{sub 2}Ru{sub 2}O{sub 7} have been investigated by neutron scattering and bulk property techniques. A single-ion process, that is thermally activated, dominates the spin-spin relaxation spectrum above 2 K. Assuming Arrhenius behaviour, we found an activation energy {delta} = (329 {+-} 6) K and characteristic relaxation time {tau}{sub 0} (5.2 {+-} 0.3) x 10{sup -12} s in the paramagnetic state, akin to those found in the spin ice, Ho{sub 2}Ti{sub 2}O{sub 7}. Atlow temperature (T<95 K) the activation energy lowers and below 20 K the entropy and ac susceptibility are similar to that observed in other spin ice compounds within a 10 kOe field.
2005-11-09
International Nuclear Information System (INIS)
The spin relaxation processes within the pyrochlore Ho_2Ru_2O_7 have been investigated by neutron scattering and bulk property techniques. A single-ion process, that is thermally activated, dominates the spin-spin relaxation spectrum above 2 K. Assuming Arrhenius behaviour, we found an activation energy #DELTA# = (329 #+-# 6) K and characteristic relaxation time #tau#_0 (5.2 #+-# 0.3) x 10"-"1"2 s in the paramagnetic state, akin to those found in the spin ice, Ho_2Ti_2O_7. Atlow temperature (T<95 K) the activation energy lowers and below 20 K the entropy and ac susceptibility are similar to that observed in other spin ice compounds within a 10 kOe field.
2005-11-09
Burning ice. Methane hydrate on the sea floor; Brennendes Eis. Methanhydrat am Meeresgrund
Energy Technology Data Exchange (ETDEWEB)
In certain regions of the sea floor, water and methane from organic depositions have turned into a burnable form of ice, i.e. methane hydrates which contain more stored energy than all fossil fuel reserves. If they should desintegrate as a result of global heating, methane will be released and will contribute to further global heating. [Deutsch] Im Boden bestimmter Meeresregionen haben sich Wasser und Methan aus organischen Ablagerungen zu einer brennbaren Form von Eis vereinigt. Diese Methanhydrate speichern mehr Energie als alle fossilen Brennstoffvorraete. Wenn sie sich bei einer globalen Erwaermung zersetzen, koennte das entweichende Methan als Treibhausgas die Erde noch mehr aufheizen. (orig.)
1999-06-01
Weld integrity of the superconducting cable aluminium jackets of W7-X
Energy Technology Data Exchange (ETDEWEB)
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, ...
2009-06-15
Weld integrity of the superconducting cable aluminium jackets of W7-X
International Nuclear Information System (INIS)
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fuer Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The weld is mechanically loaded during cool-down due to the difference in thermal contractions between the GRP insulation and the aluminium, ...
2009-06-01
TRANSPORT CHARACTERISTICS OF REPRESENTATIVE DEBRIS IN A OPEN CHANNEL
Energy Technology Data Exchange (ETDEWEB)
During LOCA(Loss of Coolant Accident), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris could be accumulated and be clogged in the recirculation sump screen. If debris blocked the sump screen, the pressure drop increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR at 1990. Considering the important of safety, US NRC published Regulatory ...
2010-05-15
Sump Pool Flow Simulation during Fill-up Phase of LOCA Using on CFD for OPR1000 Plant
Energy Technology Data Exchange (ETDEWEB)
During LOCA (Loss of Coolant Accident) in design bases accident (DBA), emergency core coolant supplements form a recirculation sump and cooled core and containment. When the double ended guillotine Break (DEGB) at the hot leg near steam generator, due to the jet impingement discharge flow, the debris could be potentially generated at pipe or wall nearby steam generator and be transported to the recirculation sump. Therefore, the debris, such as insulations and paint chips, could be accumulated and be clogged in the recirculation sump screen. If debris is blocked the sump strainer, the pressure drop is increased at the screen so as to increase the pressure loss of ECCS (Emergency Core Cooling System) pump NPSH (Net positive suction head). It is potentially influenced to decrease the long-term cooling capability of the recirculation sump. The recirculation sump screen clogging accident has happened in BWR ...
2009-10-15
Energy Technology Data Exchange (ETDEWEB)
Based on the IAPWS technical guidance on ''Instrumentation for Monitoring and Control of Cycle Chemistry for Steam-Water Circuits of Fossil-Fired and Combined Cycle Power Plants,'' the latest situation regarding instrumentation for nuclear power plants is discussed. As a result of the discussion, it is concluded that: (1) Reliable and safe operation of plants is established by the application of suitable chemical conditions in plant cooling systems, which should be supported by the selection of suitable control targets for monitoring and by the application of reliable instruments. (2) The minimum level of key instrumentation consists of on-line as well as off-line instruments for monitoring the key parameters: - on-line: pH, conductivity, cation conductivity, O{sub 2} and H{sub 2} concentrations, electrochemical corrosion potential; - off-line: radioactive nuclides ({sup 60}Co, {sup 58}Co, {sup 131}I, etc.), ...
2010-05-15
Influence of the fin orientation on the cooling of disc-brakes
International Nuclear Information System (INIS)
Nowadays, computational fluid dynamics is being applied in many fronts to improve the understanding of the flow and heat transfer behaviour in engineering applications. Unfortunately, there are not so many computational investigations regarding the ventilation and temperature distribution in discs-brakes. In this respect, this study presents a (CFD) analysis is carried out to investigate temperature distributions and flow patterns through disc brakes. The final goal is the development of shapes that optimize heat dissipation rates dictating the stopping capability of disc brakes. High performance discs brakes have a variety of cooling channels and the optimization of these passages is a challenging task for the manufacturing industry. High values of heat transfer coefficients of disc-brake configurations, are the most critical quantities during the design phase of new braking systems. In this context, a parametric study of the influence of the ...
2003-05-28
High-pressure gas quenching in cold chambers for increased cooling capacity
Energy Technology Data Exchange (ETDEWEB)
Gas quenching for the hardening of steel parts is a lower-pollution alternative to quenching in quenchants such as oil or salt. As the surfaces of the cooled parts remain clean after gas quenching, there is no need to wash them after heat treatment, which reduces the consumption of oils and detergents. The fire risk and ventilation requirements of oil quenching are eliminated. In addition, some trials have shown that gas quenching has a positive effect on distortion, representing a saving in finishing work and thus a reduction in costs. Today, gas quenching is used almost solely in vacuum furnaces. Quenching is normally performed in the same chamber as heating, which means that besides quenching the batch, the quenching system must also remove heat from the heating elements and insulation of the furnace. Previous trials performed by IVF have shown that gas quenching with helium of ball bearing and carburizing steels (and other steels) in sizes ...
1996-12-31
Wax and hydrate control with electrical power
Energy Technology Data Exchange (ETDEWEB)
Electrical heating of subsea flowlines is an effective way to prevent wax and hydrate information, especially for long transportation distances and in low-temperature deep water. Systems are available for use in conjunction with bundles, pipe-in-pipe, and wet-thermal-insulation systems. These systems provide environmentally friendly fluid-temperature control without chemicals or flaring for pipeline depressurizing. Enhanced production is achieved because no time is lost by unnecessary depressurizing, pigging, heating-medium circulation, or removal of hydrate and wax blockages. The seabed temperature at 100-m and greater water depths may range from 7 to {minus}1.5 C, causing a rapid cooling of the hot well streams being transported in subsea flowlines. Under these supercooling conditions, vulnerable crude oils and multiphase compositions will deposit wax and asphalts; also the gas/water phase may freeze ...
1997-08-01
Field performance of an energy pile system for space heating
Energy Technology Data Exchange (ETDEWEB)
This paper describes the field performance of air conditioning with an energy pile system, which was applied to the pile foundations of an actual building for the purpose of reducing the cost of the underground heat exchanger. First, the building for both office and residential use, for which a space heating and cooling system using friction piles was installed, was built in Sapporo in December 2000. Second, three tests were carried out to specify the design of a heat exchanger inside the pile, and a U-tube type underground heat exchanger was adopted from the viewpoint of energy efficiency and installation costs. Long-term space heating operation measurements indicated that the seasonal average temperatures of brine returning from the underground and pile surfaces were 2.4 and 6.7 deg C, respectively. The average coefficient of performance for space heating was quite high at 3.9, and the seasonal primary energy reduction ...
2007-05-15
International Nuclear Information System (INIS)
Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were ...
Energy Technology Data Exchange (ETDEWEB)
Reviews types of hydraulic power shovels used in coal surface mines in the USA, FRG, Japan and other countries. Excavators of the first, second and third generation are compared. Hydraulic schemes of the excavators are compared. The following excavators are reviewed: the RH-75, RH-75C, 1000 SK, H-801, RC-1500, H-185, EX-1800, R-994, RH-120C, H-241, Marion 3560, H-285, EX-3500, H-485, RH-300. The following parameters are compared: mass, price, digging range, digging power, productivity, motors, travelling speed, availability coefficient, pressure in the hydraulic systems, control systems. The following elements are discussed: schemes of hydraulic drives, main motors and engines, pump stations, hydraulic equipment, hydraulic accumulators, systems for cleaning and cooling hydraulic fluids, control systems, working fluids. Reliability of hydraulic power shovels and factors that ...
1989-01-01
A thermochemical hydrogen production system based on a high-temperature fusion reactor blanket
International Nuclear Information System (INIS)
A conceptual fusion synfuel production system has been developed with the unique features of: (1) a fusion blanket producing high-temperature (1250"0C) process heat, and (2) the GA sulfur-iodine thermochemical cycle. The system incorporates a two-zone blanket which achieves a tritium breeding ratio of 1.1 while delivering a high fraction (30%) of the fusion heat at high temperatures (1250"0C). The multiple barriers to tritium permeation in the blanket design permit the hydrogen product to meet 10CFR20 regulatory requirements without stringent requirements on the tritium recovery systems. A ceramic heat exchanger, incorporating SiC tubes and headers to contain the process stream and a cooled, Inconel 718 pressure shell to contain the helium, was designed for transferring the heat from the high-temperature coolant to the process. A good heat-line match of the blanket heatsource temperature distribution to ...
1983-04-26
Fast cooling of steam turbines. Schnellabkuehlen von Dampfturbinen
Energy Technology Data Exchange (ETDEWEB)
Due to the fast cooling of steam turbines, the shutdown time during maintenance or when repairing faults and damage can be shortened. This booklet describes various processes for cooling steam turbines. It is recommended that fast cooling should be planned in designing new plants and corresponding arrangements should be provided in the form of pipe connections and valves. (DG).
1987-01-01
A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aero...
1977-01-01
Energy Technology Data Exchange (ETDEWEB)
The mechanisms involved in the glacial inception are still poorly constrained due to a lack of high resolution and cross-dated climate records at various locations. Using air isotopic measurements in the recently drilled NorthGRIP ice core, we show that no evidence exists for stratigraphic disturbance of the climate record of the last glacial inception ({proportional_to}123-100 kyears BP) encompassing Dansgaard-Oeschger events (DO) 25, 24 and 23, even if we lack sufficient resolution to completely rule out disturbance over DO 25. We quantify the rapid surface temperature variability over DO 23 and 24 with associated warmings of 10{+-}2.5 and 16{+-}2.5 C, amplitudes which mimic those observed in full glacial conditions. We use records of {delta}{sup 18}O of O{sub 2} to propose a common timescale for the NorthGRIP and the Antarctic Vostok ice cores, with a maximum uncertainty of 2,500 years, and to examine the interhemispheric sequence of events ...
2006-02-01
Technical-ecologic principles of efficient use of open pit mine motor transport
Energy Technology Data Exchange (ETDEWEB)
The effect of open pit mine motor transport with ICE on the air basin is examined using the example of shale mines and open pits of the production association ''Estonslanets''. Efficient areas of use of different types of open pit mine motor transport, diesel-trolley tracks and electric cars are determined based on technical-economic and ecologic feasibility.
1981-01-01
Modelling the spatial and temporal evolution of winter glacier mass balance.
Environmental Research Database
DescriptionChanges in glacier mass balance are critically influenced by the distribution of snow accumulation at the start of the melt season, but models of the winter season lag seriously behind those of the melt season. The overall aim is to test physically-based models of the spatial and temporal evolution of the winter snowpack at a temperate ice cap (Langjokull, Iceland), to assess how effectively and also how efficiently they capture variation in winter accumulation. A three-step modelling approach i [continued...
2004-01-31
We developed a model for radar scattering from the lunar reoglith layer using vector radiative transfer theory. From this model, both the radar backscattering coefficient and the circular polarization ratio can be predicted analytically as a function of regolith parameters.
2010-03-01
...in your blue fuller says global warming summit on the top general information ...this because a lot of times when we talk about global warming and climate change we really focus on the ice ...site ? one organization is called global warming one-on-one and it's run by ...can actually go to global warming one-on-one and and ...something to ? slow global warming but sometimes you feel alone so the big deal if i changed my life ...
An idealized numerical simulation of mammatus-like clouds
British Library Electronic Table of Contents (United Kingdom)
A three-dimensional numerical simulation of mammatus-like clouds is presented. A portion of a cirrus outflow anvil cloud is simulated including cloud ice and snow microphysical representations. The simulated mammatus clouds appear in a cellular pattern and are compared with the few available previously published physical observations of mammatus. Copyright Copyright 2006 Royal Meteorological Society
2006-01-01
Weld integrity of the superconducting cable aluminium jackets of W7-X
British Library Electronic Table of Contents (United Kingdom)
The Wendelstein 7-X (W7-X) modular stellarator is under construction at the Max-Planck-Institut fur Plasmaphysik in Greifswald, Germany. The W7-X magnet system contains 70 coils made up from helium cooled superconducting cables in aluminium alloy (EN AW-6063) jackets. Several hundred connections of the jacket to the cable joints are made by aluminium-to-aluminium welds. Due to geometrical and thermal boundary conditions these welds cannot be accomplished free from defects. Microscopic analyses of the welds show that a variety of small flaws such as cracks and pores develop during welding. The welds have thus to be dimensioned accordingly, and appropriate weld qualification, investigation and testing has to be done in order not to jeopardise the structural integrity and leak tightness. The ...
2009-01-01
International Nuclear Information System (INIS)
The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.
1999-11-03
International Nuclear Information System (INIS)
The direct injection of steam into a water pool is a method of heat transfer used in many process industries. The amount of research in this area however is limited to the nuclear industry, with applications relating to reactor cooling systems. Electrical resistance tomography (ERT), a low cost, non-invasive and which has high temporal resolution characteristics, can be used as a visualization tool for the resistivity distribution for the steam injection into water pool such as IRWST. In this paper, three dimensional resistivity distribution of the process is obtained through ERT using iterative Gauss-Newton method. Numerical experiments are performed by assuming different resistive objects in the water pool. Numerical results show that ERT is successful in estimating the resistivity distribution for the injection of steam in the water pool
2010-10-01
The questions of liquid metal two-phase flow modelling in the FBR core channels
International Nuclear Information System (INIS)
The two-fluid model representation for calculations of two-phase flow characteristics in the FBR fuel pin bundles with liquid metal cooling is presented and analysed. Two conservation equations systems of the mass, momentum and energy have been written for each phase. Components accounted the mass-, momentum- and heat transfer throughout the interface occur in the macro-field equations after the averaging procedure realisation. The pattern map and correlations for two-fluid model in vertical liquid metal flows are presented. The description of processes interphase mass- and heat exchange and interphase friction is determined by the two-phase flow regime. The opportunity of the liquid metal two-phase flow regime definition is analysed. (author)
2000-06-01
Stability and disturbance of large dc superconducting magnets
Energy Technology Data Exchange (ETDEWEB)
This paper addresses the stability aspects of several successful dc superconducting magnets such as large bubble chamber magnets, and magnets for the Mirror Fusion Test Facility and MHD Research Facility. Specifically, it will cover Argonne National Laboratory 12-Foot Bubble Chamber magnets, the 15-foot Bubble Chamber magnets at Fermi National Laboratory, the MFTF-B Magnet System at Lawrence Livermore National Laboratory, the U-25B Bypass MHD Magnet, and the CFFF Superconducting MHD magnet built by Argonne National Laboratory. All of these magnets are cooled in pool-boiling mode. Magnet design is briefly reviewed. Discussed in detail are the adopted stability critera, analyses of stability and disturbance, stability simulation, and the final results of magnet performance and the observed coil disturbances.
1981-11-11
British Library Electronic Table of Contents (United Kingdom)
A protective film has been developed on the surface of carbon steel in low chloride aqueous environment using a synergistic mixture of an environmentally friendly phosphonic acid, N,N-bis(phosphonomethyl) glycine (BPMG), and zinc ions. Impedance studies of the metal/solution interface indicated that the surface film is highly protective against the corrosion of carbon steel in the chosen environment. Potentiodynamic polarization studies showed that the inhibitor is a mixed inhibitor. X-ray photoelectron spectroscopic analysis (XPS) of the film showed the presence of the elements iron, phosphorus, nitrogen, oxygen, carbon, and zinc. Deconvolution spectra of these elements in the surface film showed the presence of oxides/hydroxides of iron(III), Zn(OH)2, and [Zn(II)-BPMG] complex. This infe...
2011-01-01
Results of the 1986 FFTF inherent safety tests
International Nuclear Information System (INIS)
A series of tests was recently completed at the 400-MW (thermal) Fast Flux Test Facility (FFTF) to further demonstrate the passive safety characteristics of liquid-metal-cooled fast reactors. Earlier FFTF testing of decay heat removal by sodium natural circulation was reported in 1981. The main purpose of the 1986 test series was to demonstrate passive reactor shutdown during a loss-of-flow event when several inherent shutdown devices called gas expansion modules (GEMs) were installed in the reactor. However, these tests also provide further data on the natural circulation performance of the primary system, in particular the reactor core, and thus add to the data base available for checking the validity of available analytical tools.
1987-06-07
Realization of good indoor climate in low-energy office
Energy Technology Data Exchange (ETDEWEB)
Good indoor air quality and thermal comfort, as well as low energy consumption, were achieved in an environment friendly experimental METOP-office building in Espoo, Finland. The consumption of heating and cooling energy was minimized by installation of energy-efficient windows, good CFC-free thermal insulation of the building envelope, the individually-controlled ventilation and room temperatures, heat recovery and energy-storing structures. According to the study carried out in 1990-1993, the heating energy was 13 kWh/m{sup 3}, 60% lower than the average consumption. The index of the satisfaction of thermal comfort was over 90%. Concentrations of all the measured indoor air pollutants were low. Ventilation rates could be chosen in each office room from 10 to 40 dm{sup 3}/s. The noise level of the ventilation system was low and the lighting level was pleasant. (author)
1994-12-31
Novel Processing of Unique Ceramic-Based Nuclear Materials and Fuels
Energy Technology Data Exchange (ETDEWEB)
Advances in nuclear reactor technology and the use of gas-cooled fast reactors require the development of new materials that can operate at the higher temperatures expected in these systems. These include refractory alloys base on Nb, Zr, Ta, Mo, W, and Re; ceramics and composites such as those based on silicon carbide (SiCf-SiC); carbon-carbon composites; and advanced coatings. Besides the ability to handle higher expected temperatures, effective heat transfer between reactor componets is necessary for improved efficiency. Improving thermal conductivity of the materials used in nuclear fuels and other temperature critical components can lower the center-line fuel temperature and thereby enhance durability and reduce the risk of premature failure.
2008-11-30
Noise in Josephson mm-wave mixers
International Nuclear Information System (INIS)
Point contact Josephson junctions can function as millimeter wave heterodyne mixers with conversion gain. The best results achieved thus far show a single sideband conversion gain of 1.3 and a mixer contribution to the system noise temperature of 54"0K. Both of these results are approximately 5 times better than the best published figures for cooled Schottky barrier diode mixers operated at the same frequency. The measured noise for a variety of junctions can be expressed as a universal function of the normalized rf frequency #OMEGA# = h#omega#/2eI/sub c/R. It is about a factor 2 larger than the calculated noise arising from the thermal noise in the junction shunt resistance, R. The noise calculation was done for the resistively shunted junction model using an analog junction simulator.
1974-09-30
Multi-Dimensional Analysis for Sodium Hot Pool using MARS-LMR in Steady State
International Nuclear Information System (INIS)
DBEs (Design Basis Event) of KALIMER-600 (Korea Advanced Liquid Metal Reactor) were analyzed in one dimension by KAERI (Korea Atomic Energy Research Institute). KALIMER-600 is the pool type SFR (Sodium cooled Fast Reactor), thereby the sodium of primary system is prohibited movement to out of a reactor vessel. There are many contacting and including compositions in the sodium hot pool, such as IHX (Intermediate Heat eXchanger), DHX (Decay Heat eXchanger), Pump, UIS (Upper Internal Structure), and core. Moreover, the complex phenomena are occurred in sodium hot pool during steady and transient states. Therefore, the one dimensional analysis is modified to the multi-dimensional analysis through modification of sodium hot pool from one to three dimensions
2010-10-01
Memory of multiple aging stages above the freezing temperature in the Relaxor ferroelectric PLZT.
The dynamic dielectric susceptibility and the elastic compliance of the relaxor ferroelectric lanthanum lead zirconate titanate (PLZT) 9/65/35 have been measured under different cooling and heating protocols in order to study aging and memory. The memory of multiple aging stages at different temperatures has been found (several dips in the susceptibility curves on heating), as in spin glass systems below the glass transition. Remarkably, in PLZT the memory of several aging stages is retained also above the freezing temperature deduced from the dynamic susceptibilities. The results are discussed in light of the existing models of aging and memory in spin and dipolar glasses. PMID:15447139
2004-08-24
Investigation of mixed convection in a large rectangular enclosure
Energy Technology Data Exchange (ETDEWEB)
This experimental research investigates mixed convection and heat transfer augmentation by gaseous forced jets in a large enclosure, at conditions simulating those of passive containment cooling systems for Gen III+ passively safe reactors. The experiment is designed to measure the key parameters governing heat transfer augmentation by forced jets, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio. The tests cover a variety of injection modes leading to flow configurations of interest for mixing and stratification phenomena in containments under accident conditions. Correlations for heat transfer augmentation by forced jets are developed and compared with experimental data. The characteristic recirculation speed inside the enclosure is introduced and analyzed. Steady stratified temperature distributions are compared with model simulations ...
2007-05-15
Investigation of mixed convection in a large rectangular enclosure
International Nuclear Information System (INIS)
This experimental research investigates mixed convection and heat transfer augmentation by gaseous forced jets in a large enclosure, at conditions simulating those of passive containment cooling systems for Gen III+ passively safe reactors. The experiment is designed to measure the key parameters governing heat transfer augmentation by forced jets, and to investigate the effects of geometric factors, including the jet diameter, jet injection orientation, interior structures, and enclosure aspect ratio. The tests cover a variety of injection modes leading to flow configurations of interest for mixing and stratification phenomena in containments under accident conditions. Correlations for heat transfer augmentation by forced jets are developed and compared with experimental data. The characteristic recirculation speed inside the enclosure is introduced and analyzed. Steady stratified temperature distributions are compared with model simulations ...
2007-05-01
Hydrogen production in a 5 kW Diesel Oxidative Steam Reformer
Energy Technology Data Exchange (ETDEWEB)
This paper presents a reformer prototype for the production of the necessary H{sub 2} to supply a 5 kW PEMFC and its first results. The fuel processor consists of an OSR and a WGS and a PROX reactors. The design of the system was carried out with a one-dimensional model. The mixture chamber was specially studied with a CFD code (Fluent), taking into account the effect of fuel evaporation and the cool flame process. The aim of the designed facility is to be able of characterising each component and controlling each working parameter. Eventually, using diesel as fuel, results from the mixture chamber, OSR, WGS and PROX reactors are presented. It also includes conclusions and future works. (authors)
2006-07-01
The authors have studied (Al{sub x}Ga{sub 1{minus}x}){sub 0.5}In{sub 0.5}P doped with tellurium using deep level transient spectroscopy and associated electrical measurements. Several defect states are observed in the upper half of the band gap, that are believed to be intrinsic to the alloy system as well as related to the tellurium donors. Defects observed at measurement temperatures above 390 K exhibit a hysteretic behavior. The observed spectra depend on the biasing conditions applied to the Schottky diode during cooling. The hysteretic behavior suggests the existence of different defect configurations, which can be accessed under conditions of high temperatures and electrical stress, but remain stable below 300 K.
2000-02-01
Energy Technology Data Exchange (ETDEWEB)
The authors have studied (Al{sub x}Ga{sub 1{minus}x}){sub 0.5}In{sub 0.5}P doped with tellurium using deep level transient spectroscopy and associated electrical measurements. Several defect states are observed in the upper half of the band gap, that are believed to be intrinsic to the alloy system as well as related to the tellurium donors. Defects observed at measurement temperatures above 390 K exhibit a hysteretic behavior. The observed spectra depend on the biasing conditions applied to the Schottky diode during cooling. The hysteretic behavior suggests the existence of different defect configurations, which can be accessed under conditions of high temperatures and electrical stress, but remain stable below 300 K.
2000-02-01
Energy Technology Data Exchange (ETDEWEB)
Cavity type receivers are used extensively in concentrating solar thermal energy collecting systems. The Solar Total Energy Project (STEP) in Shenandoah, Georgia is a large scale field test for the collection of solar thermal energy. The STEP experiment consists of a large field array of solar collectors used to supplement the process steam, cooling and other electrical power requirements of an adjacent knitwear manufacturing facility. The purpose of the tests, conducted for this study, was to isolate and quantify the radiative, conductive, and convective components of total heat loss, and to determine the effects of operating temperature, receiver angle, and aperture size on cavity heat loss. An analytical model for radiative heat loss was developed and compared with two other methods used to determine radiative heat loss. A proposed convective heat loss correlation, including effects of aperture size, receiver operating temperature, and ...
1995-12-01
Flow visualization of liquid metal by neutron radiography
Energy Technology Data Exchange (ETDEWEB)
Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.
1994-12-31
Flow visualization of liquid metal by neutron radiography
International Nuclear Information System (INIS)
Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization test.
1994-07-01
Electron beam induced reactions in metal/Si systems
Energy Technology Data Exchange (ETDEWEB)
Thin Pt, Pd, Pt/sub 2/Si, PtSi, Pd/sub 2/Si, Ni, Mo, W, Nb, Ti, V films deposited on Si single crystal were treated by using electron beam pulses of 60 ns duration in the 0.4-4 J/cm/sup 2/ energy density range. Irradiation of these structures produces at the same time many phases. Post-thermal annealing of the reacted layer induces the formation of a stable phase, the same obtained by only thermal treatment in a conventional furnace. A linear relationship between the energy density range and the lowest eutectic temperature of the compounds formed has been found. Further SEM observations seem to identify a liquid layer from which the phases are forming by subsequent fast cooling.
1982-01-01
Electron beam induced reactions in metal/Si systems
International Nuclear Information System (INIS)
Thin Pt, Pd, Pt_2Si, PtSi, Pd_2Si, Ni, Mo, W, Nb, Ti, V films deposited on Si single crystal were treated by using electron beam pulses of 60 ns duration in the 0.4-4 J/cm"2 energy density range. Irradiation of these structures produces at the same time many phases. Post-thermal annealing of the reacted layer induces the formation of a stable phase, the same obtained by only thermal treatment in a conventional furnace. A linear relationship between the energy density range and the lowest eutectic temperature of the compounds formed has been found. Further SEM observations seem to identify a liquid layer from which the phases are forming by subsequent fast cooling. (author).
Effects of coolant chemistry on corrosion of 3003 aluminum alloy in automotive cooling system
British Library Electronic Table of Contents (United Kingdom)
In this work, effects of coolant chemistry, including concentrations of chloride ions and ethylene glycol and addition of various ions, on corrosion of 3003 Al alloy were investigated by electrochemical impedance spectroscopy measurements and scanning electron microscopy characterization. In chloride-free, ethylene glycol-water solution, a layer of Al-alcohol film is proposed to form on the electrode surface. With the increase of ethylene glycol concentration, more Al-alcohol film is formed, resulting in the increase in film resistance and charge-transfer resistance. In the presence of Cl- ions, they would be involved in the film formation, decreasing the stability of the film. In 50% ethylene glycol-water solution, the threshold value of Cl- concentration for pitting initiation is within ...
2010-01-01
Development of large scale parallel visco-elastic analysis system with mesoscopic material model
International Nuclear Information System (INIS)
We develop a large scale parallel viscous-elastic analysis program incorporating a mesoscopic self-consistent model developed by Laws. In the model, macroscopic elastic constants are treated as variables depending on the shape and statistical properties of pre-existing microscopic pores and change due to neutron irradiation. We apply this program to the visco-elastic analysis of nuclear graphite structures under neutron irradiation environment in High Temperature Gas-cooled Reactor (HTGR), as an example problem. Furthermore the calculated results by this parallel computational program are compared with those by one of commercial finite element analysis codes, FINAS, for validating elastic and thermal stress analysis function. (author)
2000-09-01
Development of Seismic Analysis Model and Time History Analysis for KALIMER-600
Energy Technology Data Exchange (ETDEWEB)
This report describes a simple seismic analysis model of the KALIMER-600 sodium cooled fast reactor and its application to the seismic time history analysis. To develop the simple seismic analysis model, the detailed 3-D finite element analyses for main components, IHTS piping system, and reactor building were carried out to verify the dynamic characteristics of each part of simple seismic analysis models. By using the developed simple model, the seismic time history analyses for both cases of a seismic isolation and non-isolation design of KALIMER-600 were performed. From the comparison of the calculated floor response spectrum, it is verified that the seismically isolated KALIMER-600 reactor building shows a great performance of a seismic isolation and assures a seismic integrity.
2007-02-15
Coupling of geothermal heat pumps with thermal solar collectors
Energy Technology Data Exchange (ETDEWEB)
The study discussed relates to the design and development of a process consisting of combining a reversible geothermal heat pump with thermal solar collectors for building heating and cooling and the production of domestic hot water. The proposed process, called GEOSOL, has been installed in a 180 m{sup 2} private residence in 2004. This installation is the subject of long-term experimental follow-up to analyse the energy-related behavior of the installation at all times of the year. In addition, different configurations of this combined system (geothermal heat pump and thermal solar collectors) have been defined and will be simulated numerically using TRNSYS software. A comparative analysis of these different alternative versions will be conducted to determine the best configuration(s) of the GEOSOL process in terms of energy, economical and environmental performances. (author)
2007-07-15
Condensation heat transfer in a steam-water stratified flow
Energy Technology Data Exchange (ETDEWEB)
Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m{sup 2}K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)
1999-07-01
Condensation heat transfer in a steam-water stratified flow
International Nuclear Information System (INIS)
Fundamental phenomena of condensation heat transfer at a steam-water interface have been studied related to the thermo-hydrodynamics of the emergency core cooling system for light water reactors. In this study temperature fluctuations near the interface and in the liquid phase were measured using fine thermocouples for a saturated steam-subcooled water co-current stratified two-phase flow in a nearly horizontal rectangular channel, and heat transfer coefficients were determined experimentally. The values of the condensation heat transfer coefficients in this experiment are from 6 to 40 kW/m"2K. In the regions of high Reynolds numbers, as the steam Reynolds numbers become larger, the average interfacial heat transfer coefficients tend to increase. The corelations of Nusselt numbers were obtained from the heat transfer data. (author)
1999-04-19
Cobalt release from PCA steel during possible fusion reactor accidents
Energy Technology Data Exchange (ETDEWEB)
Possible accident scenarios for a fusion reactor include breaches in the vacuum or cooling system. Intruding air or steam could react with structural or plasma facing materials, possibly mobilizing radioactive isotopes. Safety assessments must consider the early dose at the site boundary from the release of these activated materials. Previous calculations have indicated that cobalt isotopes dominate dose calculations for designs using stainless steel. Values used in these calculations, however, had been largely determined by the measurement limits of the chemical analysis methodology instead of measured releases. The purpose of the current study was to refine the analytical method to reduce the limit for detecting cobalt, and then test PCA steel in air and steam between 973 and 1473 K. Goals were to obtain more accurate measurements of cobalt mobilization in terms of g/m{sup 2}{center_dot}h and insight into the mobilization mechanisms.
1995-01-01
Cloud Formation and Dynamics in Cool Dwarf and Hot Exoplanetary Atmospheres
The lowest-mass stars, brown dwarfs and extrasolar planets present challenges and opportunities for understanding dynamics and cloud formation processes in low-temperature atmospheres. For brown dwarfs, the formation, variation and rapid depletion of photospheric clouds in L- and T-type dwarfs, and spectroscopic evidence for non-equilibrium chemistry associated with vertical mixing, all point to a fundamental role for dynamics in vertical abundance distributions and cloud/grain formation cycles. For exoplanets, azimuthal heat variations and the detection of stratospheric and exospheric layers indicate multi-layered, asymmetric atmospheres that may also be time-variable (particularly for systems with highly elliptical orbits). Dust and clouds may also play an important role in the thermal energy balance of exoplanets through albedo effects. For all of these cases, 3D atmosphere models are becoming an increasingly essential tool for understanding spectral and ...
2009-01-01
Application of mass spectrometry to fuels and materials testing at FFTF
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400 MW(th) sodium cooled reactor and is the largest test reactor of its type in the world. It was designed and is being operated to serve two purposes: gaining liquid metal system experience and serving as a test bed for fuels and materials. During test operations it is possible that cladding breaches and escape of fission gas to the reactor cover gas region can occur. To identify the source of such a leak all 78 fuel pin assemblies contain ''gas tag'' with a unique ''tag'' mixture in each assembly. The mass spectrometric identification of tag isotope ratios makes possible rapid location and thus faster removal (if required) of breached test pins.
Advanced Neutron Source: Plant Design Requirements
Energy Technology Data Exchange (ETDEWEB)
The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this PDR document and the set of SDD documents ...
1990-07-01
Husky Oil's White Rose gets ready to bloom
Energy Technology Data Exchange (ETDEWEB)
The South White Rose oilfield, offshore Newfoundland, owned jointly by Husky Oil (82.5 per cent ) and Petro-Canada (17.5 per cent) is being developed using a floating production storage and offloading (FPSO) system. Some industry stakeholders claim that the oil should be produced using a concrete gravity base system as used in the Hibernia Field. However, Husky Oil officials are confident that the choice of the FPSO is well justified, based on its cost effectiveness and economic viability. Several production facility options have been assessed, taking into account feasibility, deliverability, economic attributes. risk and safety . The assessment results clearly pointed to FPSO as the preferred system based on its commercial and technical flexibility, proven track record in harsh environments, its ability to produce both oil and gas in sequential development, its promise of production at full capacity earlier than a gravity ...
2000-06-01
Magmatic sulfide deposits are the most significant source of platinum-group elements (PGE) in the world. Key to understanding their genesis is determining the processes and timing of sulfide saturation, metal enrichment and crustal contamination. In this study, we have identified droplets of magmatic sulfide from the Platreef, South Africa, where droplets of sulfide have been trapped in the earliest crystallising phase, chromite. Due to their early entrapment at high temperatures, metal concentrations and ratios that they display are indicative of a very early-stage sulfide liquid in the system, as they will have cooled and fractionated within an essentially closed system, unlike interstitial blebs that crystallise in an open system as the magma cools. Analysis of these droplets in an opaque mineral like chromite by LA-ICP-MS is problematic as some of the fractionated inclusion is ...
2011-06-01
FFTF operational results: startup to 100 MWd/kg
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-MW(t) sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory in Richland, Washington, to conduct fuels and materials testing in support of the US liquid-metal fast breeder reactor program. Startup and initial power testing included a comprehensive series of nuclear and nonnuclear tests to verify the thermal and neutronic characteristics of the plant and to demonstrate its inherent safety features. Extensive reactor core characterization measurements were completed to provide the neutron and gamma spectra, fission rates, and other physics data needed to design and evaluate tests irradiated in the FFTF. A specially designed series of natural-circulation tests was performed to demonstrate the inherent safety features of the plant. Early in 1982 the FFTF began its first 100-d irradiation cycle. Since that time the plant has operated beyond expectations; it achieved a cycle capacity factor of ...
Present conditions in Greenland and the Kangerlussuaq area
International Nuclear Information System (INIS)
Greenland is the world's largest island, with an area of 2.2 million square kilometres, 80 % of which is covered by the ice sheet. The climate is Arctic, but as Greenland stretches 2600 km from north to south, there is a huge variability in climate, with temperature decreasing from south to north. Due to the influence of oceanic currents, the west coast is slightly warmer than the east coast. Precipitation also decreases strongly from the south to the north, and also with distance from the coast. Kangerlussuaq is located in the dry, continental area of central west Greenland. The bedrock of Greenland is dominated by Precambrian gneisses, with sedimentary rocks occurring in some areas of East and North Greenland, and smaller areas of basalts. All of Greenland has been glaciated several times and has thus been eroded and shaped by the ice, as it still is at the ice margin. Soils are generally thin, and especially in the ...
Two-fluid modeling of condensation in the presence of noncondensables in two-phase channel flows
Energy Technology Data Exchange (ETDEWEB)
Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture interphase is accounted for by using the stagnant film model, ...
1995-01-01
Energy Technology Data Exchange (ETDEWEB)
The third regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from December 27, 1988 to May 25, 1989. The parallel operation was resumed on April 28, 1989, 123 days after the parallel off. The facilities which were the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation and emergency electric power generation system. On the facilities which were the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out. As the results, significant in indication was observed in 8 bolts for fixing the flow-changing vanes of primary coolant pumps, and broken valve spindles were found, but other abnormality was not found. The works related to this regular inspection were accomplished ...
1990-03-01
International Nuclear Information System (INIS)
The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of ...
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
The second regular inspection of No.2 plant in Sendai Nuclear Power Station was carried out from October 5, 1987 to January 8, 1988. the parallel operation was resumed on December 8, 1987, 65 days after the parallel off. The facilities as the object of inspection were the reactor proper, reactor cooling system, measurement and control system, fuel facilities, radiation control facilities, waste facilities, reactor containment installation, and emergency power generation system. On these facilities as the object of inspection, the appearance, disassembling, leak, function, performance and other inspections were carried out, and abnormality was not found at all. The works related to this regular inspection were accomplished within the range of allowable dose based on the relevant laws. The main reconstruction works carried out during the period of this regular inspection were the change of the degree of ...
1988-08-01
Results of 1st regular inspection of No.2 unit in Sendai Nuclear Power Plant
International Nuclear Information System (INIS)
This report presents results of the 1st regular inspection of the No.2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, ...
1987-01-01
Results of 1st regular inspection of No. 2 unit in Sendai Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
This report presents results of the 1st regular inspection of the No. 2 unit of the Sendai Nuclear Power Plant. It was carried out during the period from September 22, 1986, to December 24, 1986. The inspection covered the main unit of the nuclear reactor, facilities for the nuclear reactor cooling system, facilities for the instrumentation control system, fuel facilities, radiation control facilities, disposal facilities, nuclear reactor containment facilities, and emergency power generation system. Checking of appearance, disassemblage, leak and functions-performance of these facilities was conducted and no abnormalities were found. All operations involved in the inspection were performed under conditions within the permissible dose as specified in the applicable laws. No major modification work was carried out during the period of the regular inspection. The exposure dose measurements (total dose, ...
1987-09-01
Energy Technology Data Exchange (ETDEWEB)
Support for raising energy efficiency is reported for the following five areas during 1998-2001: 1. Fuel-based energy systems with the sub-areas: Sustainable production of biofuels, including ash recycling; Cogeneration; and Large scale heat production. 2. Transport with two sub-areas: Internal combustion engines; and Electric drive-lines. 3. Power production/Power technology with the sub-areas: Hydropower; Wind power; Power transmission and distribution; and Photovoltaic solar cells. 4. Industry with the sub-areas: Processes; and Support systems in industry. 5. Buildings with the sub-areas: Heating, cooling and climatic shields; and Components and support systems. In total, 1,800 M SEK (about 180 M USD) was contributed by the Energy Administration during this period. An overview of the projects is presented in this report.
2002-01-01
Reduction of combustion emissions using hydrogen peroxide in a pilot scale combustion chamber
Energy Technology Data Exchange (ETDEWEB)
A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations of CO, as well as ...
1997-12-31
PWM applications for the electric railway traction system fed by the AC/DC dual power line
Energy Technology Data Exchange (ETDEWEB)
The latest electronic circuit technology that can be used for the electric railway traction system fed by an AC/DC dual power line was developed. This system consists of reverse conducting GTO thyristors, microprocessors, and DSP`s. In the AC power supply line section, the line converter is controlled by PWM technology to secure a high power factor and reduce the higher harmonic generation of an input current as far as possible. The line converter and motor converter use reverse conducting GTO thyristors. Since these converters are cooled using a heat pipe cooler, they are reduced in size and weight. The electric grounding point of the main power circuit is set to the negative side of the DC line for AC and DC line sections. Therefore, the AC/DC selector switch was simplified in structure. Moreover, the DC input for the auxiliary power supply can be obtained from multiple line converters using diodes. As the result of the ...
1996-01-01
Materials needs for compact fusion reactors
Energy Technology Data Exchange (ETDEWEB)
The economic prospects for magnetic fusion energy can be dramatically improved if for the same total power output the fusion neutron first-wall (FW) loading and the system power density can be increased by factors of 3 to 5 and 10 to 30, respectively. A number of compact fusion reactor embodiments have been proposed, all of which would operate with increased FW loadings, would use thin (0.5 to 0.6 m) blankets, and would confine quasi-steady-state plasma with resistive, water-cooled copper or aluminum coils. Increased system power density (5 to 15 MWt/m/sup 3/ versus 0.3 to 0.5 MW/m/sup 3/), considerably reduced physical size of the fusion power core (FPC), and appreciably reduced economic leverage exerted by the FPC and associated physics result. The unique materials requirements anticipated for these compact reactors are outlined against the well documented backdrop provided by similar needs for the mainline approaches. ...
1983-01-01
Managing system for mounted parts and spare parts of power source facilities
Energy Technology Data Exchange (ETDEWEB)
The power source facilities of JT-60 consist of poloidal magnetic coil power source, toroidal magnetic coil power source, the power generation facility for heating, operation power distribution facility and secondary cooling facility, and at the time of the experiment operation of JT-60, they supply 1300 MVA of instantaneous maximum power to loads. The component machinery and equipment of the power source facilities are installed in about 20 indoor and outdoor places, and their mounted parts are about 15,000 kinds. About 3,000 kinds of spare parts are preserved in 15 exclusively used stores. The managing system for mounted parts and spare parts of JT-60 power source facilities which possesses the functions of rapidly and efficiently carrying out the storage of large quantity of information, mutual relating and retrieval by making mounted parts and spare parts into a data base and doing their unified management with a computer was constructed. ...
1995-07-01
FFTF [Fast Flux Test Facility] Integrated Leak Rate Test Computer System
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford Site. The FFTF is the only reactor of this type designed and operated with the intent of meeting the licensing requirements of the Nuclear Regulatory Commission (NRC). Unique characteristics of the FFTF that present special challenges related to leak rate testing include thin wall containment vessel construction, cover gas systems that penetrate containment, and a low-pressure design basis accident. The successful completion in 1986 of the third FFTF Integrated Leak Rate Test (ILRT) five days ahead of schedule and 10% under budget was a major achievement for the Westinghouse Hanford Company. The success of this operational safety test was due in large part to a special local area network (LAN) of three IBM PC/XT computers that monitored the sensor data, calculated the containment vessel leak rate, and displayed test results. The multiple computer ...
Development and Application of Subchannel Analysis Code Technology for Advanced Reactor Systems
Energy Technology Data Exchange (ETDEWEB)
A study has been performed for the development and assessment of a subchannel analysis code which is purposed to be used for the analysis of advanced reactor conditions with various configurations of reactor core and several kinds of reactor coolant fluids. The subchannel analysis code was developed on the basis of MATRA code which is being developed at KAERI. A GUI (Graphic User Interface) system was adopted in order to reduce input error and to enhance user convenience. The subchannel code was complemented in the property calculation modules by including various fluids such as heavy liquid metal, gas, refrigerant,and supercritical water. The subchannel code was applied to calculate the local thermal hydraulic conditions inside the non-square test bundles which was employed for the analysis of CHF. The applicability of the subchannel code was evaluated for a high temperature gas cooled reactor condition and supercritical pressure conditions ...
2006-01-15
Conceptual study on advanced PWR system
Energy Technology Data Exchange (ETDEWEB)
In this study, the adoptable essential technologies and reference design concept of the advanced reactor were developed and related basic experiments were performed. (1) Once-through Helical Steam Generator: a performance analysis computer code for heli-coiled steam generator was developed for thermal sizing of steam generator and determination of thermal-hydraulic parameters. (2) Self-pressurizing pressurizer : a performance analysis computer code for cold pressurizer was developed. (3) Control rod drive mechanism for fine control : type and function were surveyed. (4) CHF in passive PWR condition : development of the prediction model bundle CHF by introducing the correction factor from the data base. (5) Passive cooling concepts for concrete containment systems: development of the PCCS heat transfer coefficient. (6) Steam injector concepts: analysis and experiment were conducted. (7) Fluidic diode concepts : analysis and experiment were ...
1997-07-01
Beam stabilization in SPring-8 linac for top-up injections into storage rings
International Nuclear Information System (INIS)
The SPring-8 linac has been improved to realize stable top-up injection into the SPring-8 and the NewSUBARU storage rings. The beam energy instability of 0.02% rms in the long term was achieved by means of reducing RF variations, providing beam energy compensation, reinforcement of monitor systems and introduction of beam feedback controls: Variations in the RF power and phase have been reduced by improving the voltage regulation system for the klystron modulator, and by stabilizing the temperature drift of the atmosphere and cooling water in order to reduce the phase variation. A new synchronous oscillator synchronizes a beam trigger pulse and a 2856 MHz reference signal, reducing variation in the beam charge. A beam energy compression system (ECS) was installed to compensate for accidental energy variation and reduce the energy spread. Beam feedback controls compensate for residual long-term ...
2006-03-01
Energy Technology Data Exchange (ETDEWEB)
The US Nuclear Regulatory Commission is proposing to amend the regulations that currently require that the design basis for nuclear power plants include the postulation of dynamic effects from loss of coolant accidents up to and including the double-ended rupture of the largest pipe in the reactor coolant system. Proposed modifications would allow analyses to serve as a sufficient basis for excluding dynamic effects, including but not necessarily limited to pipe whip and jet impingement, associated with specific pipe ruptures. Only dynamic effects would be impacted; current design requirements for containment sizing and discharge capacity of emergency core cooling systems would remain unchanged. This report presents a detailed analysis of value-impact associated with the proposed amendment for PWR reactor coolant loop piping and for BWR recirculation loop piping. The effect of extending application of the proposed rule ...
1985-03-29
Assessment of RELAP5 model for the University of Massachusetts Lowell research reactor
International Nuclear Information System (INIS)
RELAP5 (Reactor Excursion and Leak Analysis Program) is a system code developed at the Idaho National Environmental and Engineering Laboratory for thermal hydraulic analysis of nuclear reactors. The code RELAP5 is widely used for safety analysis studies of commercial nuclear power plants. However, recent released version of RELAP5/3.2 and over present significant capabilities for analysis of nuclear reactor research systems. As a contribution to the assessment of RELAP5/3.3 for research reactor safety analysis, experimental data from the University of Massachusetts Lowell Research Reactor UMLRR are used. The UMLRR is a 1 MW, light water moderated and cooled, graphite-reflected, open-pool type research reactor. This paper presents the development and the validation of a UMLRR-RELAP model using experimental data. For this purpose, a series of experiments were performed for benchmarking RELAP5 calculations for research reactor ...
Energy Technology Data Exchange (ETDEWEB)
To propose a new design concept of a nuclear reactor used in the space, research has been conducted on the conceptual design of a new nuclear reactor on the basis of the following three main concepts: (1) Thermionic generation by thermionic fuel elements (TFE), (2) reactivity control by rotary reflector, and (3) reactor cooling by liquid metal. The outcomes of the research are: (1) A calculation algorithm was derived for obtaining convergent conditions by repeating nuclear characteristic calculation and thermal flow characteristic calculation for the space nuclear reactor. (2) Use of this algorithm and the parametric study established that a space nuclear reactor using 97% enriched uranium nitride as the fuel and lithium as the coolant and having a core with a radius of about 25 cm, a height of about 50 cm and a generation efficiency of about 7% can probably be operated continuously for at least more than ten years at 100 kW only by reactivity control by rotary ...
1998-01-01
FFTF [Fast Flux Test Facility] Fission Gas Monitor Computer System
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled, fast neutron test reactor located on the Hanford Site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The Fission Gas Monitor System (FGMS) integrates commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows either system A or B to be taken ...
Accelerators for proton and heavy ion radiotherapy
Energy Technology Data Exchange (ETDEWEB)
The construction of Heavy Ion Medical Accelerator in Chiba (HIMAC) at the National Institute of Radiological Sciences was completed in December 1993. HIMAC consists of an injector linac, two synchrotron rings, a high energy beam transport system and a beam irradiation system. Its accelerator parameters are based on the medical requirement, and helium, carbon, neon, silicon and argon were selected as the accelerated ion species. It has 3 therapy rooms (A{approx}C). Room A has a vertical irradiation system, Room C horizontal and Room B both vertical and horizontal. Two rings can supply beams independently to the vertical and horizontal irradiation systems. Clinical trial started on June 21 1994, after several basic biological and physics experiments lasting about 2 months. Cancer is the top cause of death in Japan since 1981, and people expect good treatment results at HIMAC. Proton and heavy ion ...
1995-03-01
Thermal performance of automotive aluminium plate radiator
Energy Technology Data Exchange (ETDEWEB)
The thermal performance of an automotive radiator plays an important role in the performance of an automobile's cooling system and all other associated systems. For a number of years, this component has been given little attention with very little changing in its manufacturing cost, operation and geometry. As opposed to the old tubular heat exchanger configurations used in automotive radiators, plate heat exchangers currently form the backbone of today's process industry with their advanced performance reaching levels the designers of tubular heat exchangers can only dream of. The aluminium roll-bonding technique widely used in manufacturing the cooling compartments for domestic refrigeration units is one of the cheapest methods for heat exchanger manufacturing. Using this technique, it is possible to manufacture a wide range of heat exchanger configurations that can help augment heat ...
2005-06-01
Energy Technology Data Exchange (ETDEWEB)
This fourteenth quarterly technical progress report of the MHD Integrated Topping Cycle Project presents the accomplishments during the period November 1, 1990 to January 31, 1991. Testing of the High Pressure Cooling Subsystem electrical isolator was completed. The PEEK material successfully passed the high temperature, high pressure duration tests (50 hours). The Combustion Subsystem drawings were CADAM released. The procurement process is in progress. An equipment specification and RFP were prepared for the new Low Pressure Cooling System (LPCS) and released for quotation. Work has been conducted on confirmation tests leading to final gas-side designs and studies to assist in channel fabrication.The final cathode gas-side design and the proposed gas-side designs of the anode and sidewall are presented. Anode confirmation tests and related analyses of anode wear mechanisms used in the selection of the proposed anode ...
1992-02-01
MHD Integrated Topping Cycle Project
Energy Technology Data Exchange (ETDEWEB)
This fourteenth quarterly technical progress report of the MHD Integrated Topping Cycle Project presents the accomplishments during the period November 1, 1990 to January 31, 1991. Testing of the High Pressure Cooling Subsystem electrical isolator was completed. The PEEK material successfully passed the high temperature, high pressure duration tests (50 hours). The Combustion Subsystem drawings were CADAM released. The procurement process is in progress. An equipment specification and RFP were prepared for the new Low Pressure Cooling System (LPCS) and released for quotation. Work has been conducted on confirmation tests leading to final gas-side designs and studies to assist in channel fabrication.The final cathode gas-side design and the proposed gas-side designs of the anode and sidewall are presented. Anode confirmation tests and related analyses of anode wear mechanisms used in the selection of the proposed anode ...
1992-02-01
Larger geothermal heat pump plants in the central region of Germany
Energy Technology Data Exchange (ETDEWEB)
In recent years, several larger geothermal heat pump plants for offices or commercial areas have been designed and built in the central region of Germany, mainly in the Rhein-Main area. Systems with borehole heat exchangers (BHE; in the USA the term Vertical Loop is commonly used) as well as with shallow geothermal doublets (groundwater wells) are operational. New solutions had to be found to adapt the technology to certain site constraints, and innovative components such as thermally-enhanced grouting material have been used. This paper reviews the early development of Ground Source Heat Pumps (GSHP) for commercial buildings, gives details on a number of recent plants and discusses problems that arose during their realisation: UEG Wetzlar, a building with chemical laboratories and one of the first examples of direct cooling from BHE; DFS Langen (German Air Traffic Control Headquarters), with 154 BHE for heating and ...
2003-12-01
Development of MHD generator channel walls, 1
International Nuclear Information System (INIS)
Experimental results of compatibility tests on ceramics-metal bonded structures performed under high heat flux conditions in splash test apparatus are reported. Emphasis is placed on results of the channel wall design and its critical operating conditions under MHD environment. The module design of one cold type and three semihot type insulators have been tested. These materials were Al_2O_3, Al_2MgO_4, LaAlO_4, MgO and Sialon ceramics. The methods of cold type ceramics-metal bonding structure were studied on Al_2O_3 and Spinel spray coating technology. The refractory metallizing and ceramics-metal graded structure manufactured by HIP technologies were applied to bonding between the MgO or LaAlO_4 and metallic cooling system. The Sialon non-bonding structure was tested with mechanical supported cooling system by shrinc fitting method. The results indicated that the bonding structures made of the ...
Airborne lidar experiments at the Savannah River Plant, June 1985
Energy Technology Data Exchange (ETDEWEB)
Results are presented from a series of studies conducted at the Department of Energy (DOE) Savannah River Plant (SRP) with the NASA Airborne Oceanographic Lidar (AOL). These studies included a topographic survey of a {approximately}1000 acre lake basin (presently designated L Lake) which had been excavated for use as a cooling pond for L Reactor; a study of the movement of discharged cooling water in Pond C and the warm arm of Par Pond using Rhodamine WT dye as a tag; initial baseline studies of the vegetation cover of the Steel Creek corridor (through which the outflow of L Lake is carried to the Savannah River); and a demonstration of potential forestry applications of the AOL. These investigations were conducted over a 3-day period in June 1985. The AOL is an advanced airborne laser system capable of making temporal or time history measurements of laser backscatter (bathymetry mode) or spectral measurements of laser ...
1987-09-01
Spectroscopy of a narrow-line laser cooling transition in atomic dysprosium
The laser cooling and trapping of ultracold neutral dysprosium has been recently demonstrated using the broad, open 421-nm cycling transition. Narrow-line magneto-optical trapping of Dy on longer wavelength transitions would enable the preparation of ultracold Dy samples suitable for loading optical dipole traps and subsequent evaporative cooling. We have identified the closed 741-nm cycling transition as a candidate for the narrow-line cooling of Dy. We present experimental data on the isotope shifts, the hyperfine constants A and B, and the decay rate of the 741-nm transition. In addition, we report a measurement of the 421-nm transition's linewidth, which agrees with previous measurements. We summarize the laser cooling characteristics of these transitions as well as other narrow cycling transitions that may prove useful for cooling Dy.
2010-01-01
Control of quench distortion for steel parts
Energy Technology Data Exchange (ETDEWEB)
There are two types in quench distortion of steel parts: thermal distortion and transformation distortion. Quench distortion is caused mainly by uneven cooling rate of steel parts from Austenitising temperature. The rapid cooled side is lengthened (convex deformation); the slow cooled side is shortened (concave deformation). So, to control the quench distortion, it is necessary to regulate the cooling rate of steel parts during quenching. TWO COMPONENTS produce the quench distortion of steel parts: the thermal stress and transformation stress. Generally, the effect of the thermal stress on the quench distortion is stronger than the transformation stress. The quench distortion is caused by uneven cooling rate of the steel parts, from Austenitising temperature to Ms point and Ms-Mf range. So, to control the quench distortion, it is very important to regulate the ...
1996-12-31
A drift dye tracer experiment, using Rhodamine (WT) dye, was conducted on airborne drift from a natural draft cooling tower at PEPCO's Chalk Point, Maryland Power Generating Station. This experiment was designed to separate and identify cooling tower aerosol deposition from other sources and to provide a data base for use in cooling tower salt loading and model validation. Prior to the experiment, laboratory tests showed that Rhodamine (WT) was inexpensive, safe and controllable when used as a drift dye tracer. Positive identification and separation of cooling tower drift can be made among other sources using a dye tracer.
1977-08-01
TASK 2.5.4 DEVELOPMENT OF AN ENERGY SAVINGS CALCULATOR
Energy Technology Data Exchange (ETDEWEB)
California s major energy utilities and the California Energy Commission (CEC) are seeking to allocate capital that yields the greatest return on investment for energy infrastructure that meets any part of the need for reliable supplies of energy. The utilities are keenly interested in knowing the amount of electrical energy savings that would occur if cool roof color materials are adopted in the building market. To meet this need the Oak Ridge National Laboratory and the Lawrence Berkeley National Laboratory (LBNL) have been collaborating on a Public Interest Energy Research (PIER) project to develop an industry-consensus energy-savings calculator. The task was coordinated with an ongoing effort supported by the DOE to develop one calculator to achieve both the DOE and the EPA objectives for deployment of cool roof products. Recent emphasis on domestic building energy use has made the work a top priority by the Department of Energy s (DOE) ...
2010-03-01
Energy Technology Data Exchange (ETDEWEB)
In this work, a comprehensive model including heat transfer, fluid flow and solidification was used to evaluate the performance of a novel delivery system for a single-belt steel casting process. This near-net-shape casting, although still in development, is one of the most promising routes for casting of low-carbon steel in large scale. This paper focuses on the performance of a low-Re {kappa}-{epsilon} model that was employed to simulate the three-dimensional turbulent flows fully-coupled with heat transfer and macroscopic solidification. Simulations were run for the intended conditions of caster operation, and the results obtained with the {kappa}-{epsilon} were compared with the results obtained with an ad hoc viscosity model, where the molecular viscosity was boosted 100 times, uniformly throughout the computational domain. A semi-analytical solution was employed for validating the models and the results showed that the ad hoc viscosity model overestimated the ...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
The heating system of the `Centre integre de mecanique industrielle de la Chaudiere`, in Saint-Georges, Quebec, is based on a solar wall and a geothermal heat pump with a glycol/water mixture circulating in 44 wells that are 100 m deep. With installation costs below $25 per sq.m, more than 85 per cent of the heating needs of the 9500 sq.m centre were supplied by geothermal power. The geothermal heat pump is composed of a well field and two 211-kW cooling units, each equipped with four coiled compressors. In winter, heat is pumped from the earth and in summer, a heat exchanger with control valves allows to heat to be dumped back into the earth. The monitoring and simulation of the system proved its efficiency, considering the climatic conditions in Quebec. The annual consumption of geothermal heating is 0.146 GJ per sq.m, which is very low compared to the consumption of electric heating (0.286 GJ per sq.m) or oil heating ...
1996-12-01
Phase diagram of the ternary system lauric acid-capric acid-naphthalene
Energy Technology Data Exchange (ETDEWEB)
The mixture of lauric acid and capric acid is a potential latent heat storage material. However, its eutectic melting temperature is quite high for low-temperature thermal energy storage. Addition of naphthalene is proposed. The ternary system lauric acid-capric acid-naphthalene has been investigated by differential scanning calorimetry (DSC), visual polythermal and chromatography of gases. The phase diagram is of an incongruent eutectic type. The eutectic mixture contains 18.4mol% lauric acid, 63.1mol% capric acid and 18.5mol% naphthalene and melts at 13.3{sup o}C. The peritectic mixture contains 32.4mol% lauric acid, 48.2mol% capric acid and 19.4mol% naphthalene and peritectic temperature of 16.2{sup o}C. The incongruent compound was analysed to be CH{sub 3}(CH{sub 2}){sub 10}COOH.CH{sub 3}(CH{sub 2}){sub 8}COOH. The melting temperature of the lauric acid-capric acid-naphthalene eutectic mixture makes it suitable for cooling applications.
2004-12-15
New developments in dry spent fuel storage
International Nuclear Information System (INIS)
As shown in various new examples, HABOG facility (Netherlands), CERNAVODA (Candu - Romania), KOZLODUY (WWER - Bulgaria), CHERNOBYL ( RMBK - Ukraine), MAYAK (Spent Fuel from submarine and Icebreakers - Russia), recent studies allow to confirm the flexibility and performances of the CASCAD system proposed by SGN, both in safety and operability, for the dry storage of main kinds of spent fuel. The main features are: A multiple containment barrier system: as required by international regulation, 2 independent barriers are provided (tight canister and storage pit); Passive cooling, while the Fuel Assemblies are stored in an inert atmosphere and under conditions of temperature preventing from degradation of rod cladding; Sub-criticality controlled by adequate arrangements in any conditions; Safe facility meeting ICPR 60 Requirements as well as all applicable regulations (including severe weather conditions and earthquake); Safe ...
2001-06-18
Mechanical Engineering and Design of the LHC Phase II Collimators
Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are embedded in the jaws to fasten setup time and improve beam ...
2010-01-01
Innovative coke oven gas cleaning system for retrofit applications. Volume 1, Public design report
Energy Technology Data Exchange (ETDEWEB)
This Public Design Report provides, in a single document, available nonproprietary design -information for the ``Innovative Coke Oven Gas Cleaning System for Retrofit Applications`` Demonstration Project at Bethlehem Steel Corporation`s Sparrows Point, Maryland coke oven by-product facilities. This project demonstrates, for the first time in the United States, the feasibility of integrating four commercially available technologies (processes) for cleaning coke oven gas. The four technologies are: Secondary Gas Cooling, Hydrogen Sulfide and Ammonia Removal, Hydrogen Sulfide and Ammonia Recovery, and Ammonia Destruction and Sulfur Recovery. In addition to the design aspects, the history of the project and the role of the US Department of,Energy are briefly discussed. Actual plant capital and projected operating costs are also presented. An overview of the integration (retrofit) of the processes into the existing plant is presented and is followed ...
1994-05-24
Energy Technology Data Exchange (ETDEWEB)
In response to the Clean Coal II solicitation, Bethlehem Steel Corporation (BSC) submitted a proposal to the DOE in May 1988. The proposal submitted by BSC describes a Unique integration of commercial technologies developed by Davy/Still Otto to clean coke oven gas being produced at its Sparrows Point, Maryland steel plant. This innovative coke oven gas cleaning system combines secondary gas cooling with hydrogen sulfide and ammonia removal, hydrogen sulfide and ammonia recovery, ammonia destruction and sulfur recovery to produce a cleaner fuel gas for plant use. The primary environmental benefit associated with employing this innovative coke oven gas cleaning system is realized when the fuel gas is burned within the steel plant. Emissions of sulfur dioxide are reduced by more than 60 percent. The removal, recovery and destruction of ammonia eliminates the disposal problems associated with an unmarketable ammonium sulfate ...
1990-01-01
IEA Greenhouse Gas R and D Programme annual report 1998
Energy Technology Data Exchange (ETDEWEB)
The report outlines the role of the IEA Greenhouse Gas R and D Programme, gives details of participants and of publications and summarises achievements of 1998. A successful conference on Greenhouse Gas Control Technologies was held in Interlaken, Switzerland. Technical studies reported include novel power generation concepts for removing carbon dioxide prior to or after combustion, using seawater for CO{sub 2} capture, investigating carbon dioxide sequestration in conjunction with enhanced coalbed methane recovery and applying retrofitting to power plants and to offshore oil and gas platforms. Systems studies taking a broader view include investigating the potential for combined energy systems (power generation with district heating, power with district cooling etc.) to reduce CO{sub 2} abatement cost, studies on the LNG/power generation fuel cycle, assessing the potential of methanol as an energy carrier investigating ...
1999-07-01
Hydrogen synthesis via combustion of fuel-rich natural gas/air mixtures at elevated pressure
Energy Technology Data Exchange (ETDEWEB)
Combustion of extremely fuel-rich ({phi}=4) methane/air mixtures at elevated pressures is investigated as a potential means to generate molecular hydrogen by non-catalytic partial oxidation. This system is investigated both computationally and experimentally. The computations use a perfectly-stirred reactor model and an explicit methane cool-flame mechanism to investigate the effects of reactor parameters on reaction time and product composition. Under adiabatic conditions, such mixtures are predicted to autoignite at low temperatures {approx}700 K for pressures exceeding 8.5 atm. Above 15 atm, conversion to products is complete in roughly 1 s. The dependence of reaction time and hydrogen yield is investigated as a function of inlet temperature, system pressure, and flame equivalence ratio. Actual product yields are measured in a tube reactor facility, and many of the predictions of the model, including long relaxation ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
Ventilation, cooling and illumination of modern high-rise office buildings with high-quality thermal insulation (average k-value 1.0 W/m12K) and high loads from office machinery (up to 20 W/m12 and beyond) are problematic even for modern facility management systems, with consequences for the building shell, heating system, and window ventilation. [Deutsch] Die Lueftung, Kuehlung und Beleuchtung moderner Buerohochbauten mit extremer Waermedaemmung (mittlerer K-Wert 1,0 W/m{sup 2}K) und hohen Bueromaschinenlasten (bis zu 20 W/m{sup 2} und mehr) verursachen auch heute noch erhebliche Probleme, obwohl die technische Gebaeudeausruestung weiterentwickelt wurde. Dies zeigt sich vor allem bei der Fassadenausbildung der Heizung und Fensterlueftung. (orig.)
1999-11-01
FFTF [Fast Flux Test Facility] fuel handling experience (1979--1986)
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF)is a 400 MW (th) sodium-cooled fast flux test reactor located on the Hanford Site in southeastern Washington State. The FFTF is operated by the Westinghouse Hanford Company for the United States Department of Energy. The FFTF is a three loop plant designed primarily for the purpose of testing full-scale core components in an environment prototypic of future liquid metal reactors. The plant design emphasizes features to enhance this test capability, especially in the area of the core, reactor vessel, and refueling system. Eight special test positions are provided in the vessel head to permit contact instrumented experiments to be installed and irradiated. These test positions effectively divide the core into three sectors. Each sector requires its own In-Vessel Handling Machine (IVHM) to access all the core positions. Since the core and the in-vessel refueling components are submerged under sodium, all handling ...
1987-09-01
Dynamic interactions and competing objectives in multifamily green building design
Energy Technology Data Exchange (ETDEWEB)
This paper describes the challenges involved in the construction of a mid-rise housing development in Boston, Massachusetts, during which the development team elected to upgrade the initial design criteria from Minimum Building Code to Energy Star and Leadership in Energy and Environmental Design (LEED) certification. The various constraints imposed on the development were discussed, including constraints imposed by the involvement of substantial public funds as well as the constraints imposed by various funding sources that were approached to leverage energy efficiency and green building investment via competitive grant solicitations. Building owner and utility cost management priorities were outlined along with details of central mechanical system selection. Issues concerning isolation and compartmentalization were examined along with indoor pollution source control. A building load analysis was presented as well as details of daily heating and ...
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The five thermal-hydraulic concepts chosen for advanced PWR have been studied as follows: (1) Critical Heat Flux: Review of previous works, analysis of parametric trends, analysis of transient CHF characteristics, extension of the CHF date bank, survey and assessment of correlations, design of a intermediate-pressure CHF test loop have been performed. (2) Passive Cooling Concepts for Concrete Containment system: Review of condensation phenomena with noncondensable gases, selection of a promising concept (i.e., use of external condensers), design of test loop according to scaling laws have been accomplished. and computer programs based on the control-volume approach, and the conceptual design of test loop have been accomplished. (4) Fluidic Diode Concepts: Review of previous applications of the concept, analysis major parameters affecting the performance, development of a computational code, and conceptual investigation of the verification test ...
1995-08-01
Cataclysmic Variables and a Candidate Helium White Dwarf in the Globular Cluster NGC 6397
We have used HST/FOS to study faint UV stars in the core of the nearby globular cluster NGC 6397. We confirm the presence of a 4th cataclysmic variable (CV) in NGC 6397 (CV 4), and we use the photometry of Cool et al. (1998) to present evidence that CVs 1--4 all have faint disks and probably low accretion rates. By combining these results with new UV spectra of CV 1 and the published spectra of Grindlay et al. (1995) we present new evidence that CVs 1--3 may be DQ Her systems, and we show that CV 4 may either be a dwarf nova or another magnetic system. Another possibility is that the CVs could be old novae in hibernation between nova eruptions. We also present the first spectrum of a member of a new class of UV bright stars in NGC 6397. These faint, hot stars do not vary, unlike the CVs, and are thus denoted as ``non-flickerers'' (NFs). Like the CVs, their spatial concentration is strongly concentrated toward the cluster ...
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
Isobaric contaminants are often problematical in accelerated negative ion beams for research at certain radioactive ion beam (RIB) and accelerator mass spectrometry (AMS) facilities since their presence in low-intensity rare isotopic beams seriously compromise experimental results. This article describes a non-resonant, laser-based photo-detachment apparatus for use at these facilities, which, according to calculations efficiently removes isobaric contaminants from these beams. The advantage of the system for isobaric contaminant removal over other systems proposed to date lies in its ability to efficiently capture easily transportable energetic negative ion beams with low, intermediate or high energy spreads by a superconducting solenoid magnetic field. The ability to change the diameter of captured beams by adjusting the magnetic field strength permits optimum control of the radial overlap of the laser/negative ion beam profiles over an ...
2008-09-01
Advanced PWR technology development -Development of advanced PWR system analysis technology-
Energy Technology Data Exchange (ETDEWEB)
The primary scope of this study is to establish the analysis technology for the advanced reactor designed on the basis of the passive and inherent safety concepts. This study is extended to the application of these technology to the safety analysis of the passive reactor. The study was performed for the small and medium sized reactor and the large sized reactor by focusing on the development of the analysis technology for the passive components. Among the identified concepts the once-through steam generator, the natural circulation of the integral reactor, heat pipe for containment cooling, and hydraulic valve were selected as the high priority items to be developed and the related studies are being performed for these items. For the large sized passive reactor, the study plans to extend the applicability of the best estimate computer code RELAP5/MOD3 which is widely used for the safety analyses of the reactor system. The improvement and ...
1995-07-01
A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath
International Nuclear Information System (INIS)
The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in the heat transfer process. A physical model of simultaneous ...
1985-10-01
International Nuclear Information System (INIS)
To investigate the effect of external loads arising from differential thermal expansion between a substrate and a surface-mount component during thermomechanical cycling, specimens with a nickel surface-mount component on a copper substrate were prepared. Specimens consisted of two 100 #mu#m thick 1 mm"2 solder joints about 9 mm apart, with two designs. In one specimen (denoted 'dual-shear'), the as-fabricated joints were not stressed due to differential contraction during solidification and cool down. In the other specimen (denoted 'component'), a continuous copper substrate between the joints caused the nickel component to be put in compression during cool down, which imposed shear on the joints. To impose differential thermal shear strains, the 'dual-shear' specimen was clamped to a copper block to cause a significant reversal in sign of the shear imposed on the solder joint during cycling. In the 'component' specimen configuration, the ...
2006-04-15
Operational reactor physics analysis codes (ORPAC)
International Nuclear Information System (INIS)
Full text: Research reactors have been playing a multi dimensional role in areas of nuclear fuel cycle programme, radio-isotope productions, neutron beam research etc. To ensure an efficient, smooth and safe operation of a nuclear research reactor, many reactor physics evaluations are required on routine basis. As part of reactor core management the important activities are maintaining core reactivity status, core power distribution, xenon estimations, safety evaluation of in-pile irradiation samples and experimental assemblies and assessment of nuclear safety in fuel handling/storage. In-pile irradiation requires a prior estimation of the reactivity load due to the sample, heating rate and the activity developed in it during irradiation. For the safety of the personnel handling irradiated samples the dose rate at the surface of shielded flask housing the irradiated sample should be less than 200 mR/Hr. Therefore, a proper shielding and radioactive cooling of the ...
Grate monitoring systems, state of the art; Metoder foer rosteroevervakning, dagslaegesbestaemning
Energy Technology Data Exchange (ETDEWEB)
During a number of years research and development projects have been made to present methods of monitoring the grate in a grate fired boiler. The monitoring is interesting in order to be able to increase efficiency, increase burn-out of ash, improve the status of emissions, improve transportation of ash and fuel through the furnace, reduce costs for operation and maintenance, handle greater loads etc. Improvement of the combustion has been concentrated to the development of the gas phase combustion. In the past few years the computer development has progressed rapidly and the use of optical monitoring methods have been made possible for monitoring grates. To analyse state of the art of optical grate monitoring systems three different methods have been used, literature search, inquiry where plant owners were asked if they have used grate monitoring systems and if so what experiences they have, and interviews with scientists and users. The ...
2001-01-01
Roof slab cooling device in a FBR type reactor
International Nuclear Information System (INIS)
Purpose: To obtain a roof slab cooling device capable of retaining cooling performance even in a case of electric power supply stop or failure and effective from economical point of view. Constitution: Atmospheric air is introduced into the cooling chamber of a proof slab and spontaneously passed to a exit pipeway connected to a stack thereby cooling the roof slab. Specifically, atmospheric air entered from the inlet pipeway is introduced to the cooling chamber and absorbs heat generate from the inside of the reactor container. Warmed air is sucked from the exit pipeway and then released into the atmosphere passing through the stack. The air cools the roof slab during circulation due to spontaneous passage and keeps the slab at a low temperature. Since the air is passed spontaneously, no power such as for a blower is required at all and, if the electric power ...
1986-05-16
International Nuclear Information System (INIS)
This guide describes an acceptable method of complying with the Commission's regulations with regard to the quality assurance requirements for the packaging, shipping, receiving, storage, and handling of items for water-cooled nuclear power plants.
Legionella fairfieldensis sp. nov. isolated from cooling tower waters in Australia.
UK PubMed Central (United Kingdom)
Three Legionella-like organisms were isolated from water from the cooling towers of two Australian institutions. The strains grew on buffered charcoal-yeast extract (BCYE) agar but not on BCYE agar...Full Text Available
1991-03-01
Doublet III vacuum vessel neutral beam armor
The evolution of the Doublet III neutral beam armor is followed from the initial design of a radiation cooled metallic tile to the present actively cooled graphite design. Results of the thermal and stress analyses that dictated the present design are reviewed.
1979-11-01
A comprehensive approach to cooling tower design
Energy Technology Data Exchange (ETDEWEB)
In this paper, a mathematical model for a counterflow wet cooling tower is derived, which is based on one-dimensional heat and mass balance equations using the measured heat transfer coefficient. The balance equations are solved numerically to predict the temperature change of air and water, as well as the humidity as a function of the cooling tower high. Experimental measurements on two pilot-scale cooling towers were carried out in order to analyze the performance of different cooling tower filling materials. Also, the performance of other cooling tower elements, such as droplet separators and water spray nozzles, was investigated in the pilot experiments. The flow distribution, i.e. the velocity field, upstream to the filling material was predicted using the three-dimensional version of the computational fluid dynamics (CFD) code Fluent/UNS, version 4.2. The calculated flow ...
2001-06-01
A Multi-Method Process Evaluation for a Skin Cancer Prevention Diffusion Trial
UK PubMed Central (United Kingdom)
This article describes process evaluation methods for the Pool Cool Diffusion Trial across four years. Pool Cool is a skin cancer prevention program that was...Full Text Available
2009-06-01
Building a Construction Curriculum for Your School District
Embracing the notion of going green, an affluent school district in Pennsylvania spent $83 million as part of the high school's renovation and expansion project. The three-level addition is now equipped with self-dimming lights, energy-efficient windows, a rooftop solar water heater, and a geothermal cooling and heating system. As a bonus for going green, the school district received a $250,000 grant from the Pennsylvania Department of Environmental Protection. The district used that money to create an information center in the lobby of the building where a touch-screen computer provides students, staff, and visitors with data related to the operation of the school's energy-efficient water and electrical systems. The system will graphically depict utility use over the course of a year. The monitoring system and touch-screen computer can turn this school into a living lab, with ...
2010-06-01
3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4
International Nuclear Information System (INIS)
This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly stopped within the ...
2006-11-13
Environmental Research Database
ObjectivesThe overall scientific aim of this project is, through development of an appropriate numerical modelling tool, to identify and investigate the mechanisms that control the current observed rapid thinning and acceleration of Greenland outlet glaciers and to investigate their likely future behaviour in the context of climate warming. This aim is addressed through the four major specific objectives below. These objectives build on each and therefore the order of priority is driven by the order in wh [continued...]DescriptionCurrently, the Greenland ice sheet is undergoing rapid changes in the coastal regions which have been attributed to a general warming trend to the regions climate over the last decade. Several of the narrow and fast flowing outlet glaciers that drain the ice sheet into the sea are observed to have accelerated their flow and thinned. For instance, Jakobshavn Isbrae on the West coast of Greenland has almost doubled its ...
2008-01-31
Diffuse high-energy neutrino searches in AMANDA-II and IceCube: results and future prospects
Energy Technology Data Exchange (ETDEWEB)
The AMANDA-II data collected during the period 2000-2003 have been analysed in a search for a diffuse flux of high-energy extra-terrestrial muon neutrinos from the sum of all sources in the Universe. With no excess events seen, an upper limit of E{sub {nu}}{sup 2} xs dN{sub {nu}}/dE{sub {nu}} < 7.4 x 10{sup -8} GeV cm{sup -2} s{sup -1} sr{sup -1} was obtained. The sensitivity of the diffuse analysis of IceCube 9 string for 137 days of data is calculated to be E{sub {nu}}{sup 2} x dN{sub {nu}}/dE{sub {nu}} < 1.3 x 10{sup -7} GeV cm{sup -2} s{sup -1} sr{sup -1}. No excess events are observed, which confirms the AMANDA-II upper limit.
2008-07-15
Cost guide. Volume 6. Cost-estimating methods and techniques
Energy Technology Data Exchange (ETDEWEB)
There are many requirements for cost analysis and estimating within the Department of Energy (DOE). As projects go through the many stages of planning, source evaluation and selection, contracting, and construction, different estimating requirements exist and different techniques are available to the estimator. This cost guide illustrates how quantity takeoff estimating is performed when adequate design data are available, and it shows how statistics can be applied to obtain parametric cost estimates. Parametric techniques will become increasingly useful as the Department's cost data base and Cost Estimating Relationships (CERs) are developed. Other cost guides developed by the Independent Cost Estimating (ICE) Staff will be published and disseminated soon. The section on parametric cost estimating uses Department of Defense examples since the ICE Staff considered this information to be some of the best available on this subject. Also, ...
1982-05-01
Penicillium crustosum is common in food and feed both in subtropical and temperate regions. Recently, it has also been found occurring frequently in glacier ice, sea ice and sea water of Arctic regions of Svalbard. The aim of the study was to compare isolates of the same fungal species from widely different habitats and geographic regions to see if the nutritional physiology and the profile of secondary metabolites were consistent or depended on the isolation source. All 121 strains examined produced the following families of secondary metabolites: penitrems (100%), roquefortines (100%), terrestric acids (99.2%) and viridicatols (100%), whereas 81 of 83 Arctic isolates additionally produced andrastin A. However, only 8 of 38 non-Arctic isolates produced detectable andrastin A. The quantitative profiles of 96 strains were compared using cluster, principal component and correspondence analyses. There was no clear grouping of Arctic versus ...
2004-12-22
Transient natural convection cooling of a vertical circular cylinder
International Nuclear Information System (INIS)
(1974). Netherlands Ferreira, S. Rio de Janeiro Univ. (Brazil) v. 31(3)
International Nuclear Information System (INIS)
... thermal power plants thermal reactors water cooled reactors WATER
Natural convection cooling for offshore nuclear power plants
International Nuclear Information System (INIS)
(May 1974). United States Klystra, CD Univ. of Florida, Gainesville v.
Natural convection cooling for offshore nuclear power plants
International Nuclear Information System (INIS)
(1973). United States Kylstra, CD West Palm Beach, Florida, USA. 25 Apr 1973.
1973-04-25
MAY 1988. - NASA Technical Reports Server
disciplinary methods were used to independently determine the aerodynamic loads, the thermal response, and strardural performance of the hydrogen cooled ...
Fuel cycle of reactor SVBR-100
International Nuclear Information System (INIS)
... fast reactors fbr type reactors fuels liquid metal cooled reactors materials nuclear
Behavior of the cooling towers as a function of the time
International Nuclear Information System (INIS)
In the scope of the nuclear plants lifetime study, the behavior of the cooling towers is discussed. The main geometrical characteristics of the cooling towers in the French nuclear power plants, are presented. The surveyance program, the risks of accident, the research and development actions are considered. The results of the investigations of the cooling tower structure show that it is a multidiciplinary problem and needs the development of experimental and theoretical methods. Concerning the regenerators, the surveyance actions under operating conditions, the accelerated aging tests, and some aspects of the mechanical resistance, are underlined. It is shown that mainly the creep tests will allow the lifetime estimation of the materials developed for the regenerators.
1988-12-01
Advanced Gas Cooling Study for the Hospital at Davis ...
... The performance at reduced condenser water temper- atures was assumed to be the same as that of the single-effect unit. ...
1999-01-01
Terra Nova: taming the North Atlantic
Energy Technology Data Exchange (ETDEWEB)
The Terra Nova offshore oil project is described, with emphasis on the construction of the Terra Nova Floating Production Storage and Offloading (FPSO) vessel, the first such vessel constructed for the harsh environment of the North Atlantic off Newfoundland, the site of an oil field that is expected to produce 125,000 to 150,000 barrels of oil per day starting in 2001. The vessel has a double-hull, made of 3,000 tons of reinforced steel to protect it from ice in the form of massive icebergs or crusty 'packs'. The vessel has the world's largest quick release turret, meaning that the vessel can be quickly disconnected from its turret and mooring in the event of an encroaching iceberg, and then reconnected in an environmentally sound way. Apart from its extremely rugged construction, protecting the FPSO vessel against icebergs is accomplished by way of 'hosing down' (by melting by powerful streams of water) or ...
2000-08-01
Environmental Research Database
ObjectivesNot EnteredDescriptionMethane hydrate in an ice-like substance consisting of molecules of methane gas combined chemically with water. It is stable at high pressures and low temperatures. Since the ocean floor is normally cold, but temperatures increase with depth inside the Earth, such conditions normally prevail for a few hundred meters below the seafloor where the ocean depth is more than a few hundred metres. Methane beneath the ocean floor is formed by the decomposition of organic material. At the edges of the co [continued...
2006-01-30
Application of fracture mechanics to cementitious composites
Energy Technology Data Exchange (ETDEWEB)
This work contains 27 chapters which cover recent advances in fracture mechanics applied to cement-based composites: concrete, reinforced concrete, and fiber reinforced concrete. The book, based on a NATO Advanced Study Institute, is a comprehensive survey of treating nonlinearity associated with crack growth in brittle materials such as cement composites, rocks and ice. The book is divided into 8 major themes: advances in nonlinear fracture mechanics; fracture processes; numerical modelling of fracture; experimental methods of determining fracture parameters; damage and continuum modelling; strain-rate and dynamic effects of crack propagation; stress-corrosion, time and temperature effects on fracture; and implications for concrete structures.
1985-01-01
International Nuclear Information System (INIS)
In one of the first uses of high Tc superconductors in an end-use product, Lake Shore Cryotronics and a Swiss lab have developed a liquid nitrogen level sensor using a high Tc thin film. The probe is manufactured using a seamless stainless steel tube with an yttrium-based zirconium oxide flame-sprayed on the tube. A plasma-sprayed superconductor compound is deposited on top of that. The probe is coated with a sealant that protects the superconducting film from the atmosphere. This manufacturing method has yielded an extremely durable product. Unaffected by ice formation and related mechanical problems, the superconducting level sensor can be kept in the dewar for long periods of time.
Thermogalvanic effects on the pitting corrosion of water-cooled heat exchangers
Energy Technology Data Exchange (ETDEWEB)
Thermogalvanic corrosion of St3 steel in a temperature range from 25 to 50{degrees}C with a 3.84{degrees}C/cm gradient was studied in a neutral media flow. It is shown that the thermogalvanic effect on the pitting corrosion of water-cooled heat exchangers is decisive but dual. Depending on the composition of the cooling medium, thermogalvanic corrosion may either enhance (0.5 M NaCl) or inhibit (tap water) pitting corrosion.
1995-05-01
Cooling device for rotors of multistage axial steam turbines
International Nuclear Information System (INIS)
The invention concerns an improvement of a cooling device for rotors of multistage axial steam turbines by providing in the first stage of each group of turbine stages a circulation loop connecting the wheel chamber on the inlet side of the rotor disc of the first stage with the wheel chamber on its outlet side. This is to cause the cooling effect not to be hampered by gap widths of the seal in the bottom range of the rotor blades changing during operation. Design particulars are described in detail. (UWI).
International Nuclear Information System (INIS)
Research highlights: #-># The building occupancy affecting the cooling load prediction is studied. #-># PENN model is adopted in this study for predicting the building cooling load. #-># Statistical approach is adopted to result a less prejudice prediction performance. #-># Results show that occupancy data can significantly improve the prediction. -- Abstract: Building cooling load prediction is one of the key factors in the success of energy-saving measures. Many computational models available in the industry today have been developed from either forward or inverse modeling approaches. However, most of these models require extensive computer resources and involve lengthy computation. This paper discusses the use of data-driven intelligent approaches, a probabilistic entropy-based neural (PENN) model to predict the cooling load of a building. Although it is common knowledge that the presence ...
2011-07-01
Website Policies and Important Links Comments