Status of neutron cross sections for reactor dosimetry
International Nuclear Information System (INIS)
The status of neutron activation cross sections for some threshold reactions important for reactor materials dosimetry is reviewed. An attempt is made to understand and explain discrepancies between integral and differential data, using recent available experimental results. The importance of standard and benchmark neutron fields for testing differential data for reactor dosimetry is emphasized and the Interlaboratory Reaction Rate (ILRR) program, as well as a similar program pursued by the IAEA, are briefly described.
1976-07-06
Energy Technology Data Exchange (ETDEWEB)
This additional protocol to the agreement between France, EURATOM and the IAEA aims at reinforcing the nuclear weapons non-proliferation regime. This protocol widens the field of competences of the IAEA with the supply of new information relative to: the civil nuclear cooperation between France and countries having no nuclear weapons in the domain of fuel cycle; the regular inspection of French nuclear facilities; the trade (import and export) of medium- or high-level radioactive wastes containing plutonium, highly enriched uranium or {sup 233}U, and the trade of some non-nuclear equipments or materials with countries having no nuclear weapons. The protocol defines also some practical dispositions relative to the delays and periodicity of controls, to the transmission of data, to the appointment of IAEA inspectors and their access to the facilities and sites ...
2002-07-01
Energy Technology Data Exchange (ETDEWEB)
Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.
1982-01-01
Physical aspects of quality assurance in radiotherapy: A protocol for quality control
International Nuclear Information System (INIS)
In consistency with the increasing requests from Member States for establishing radiotherapy programmes, an IAEA Technical Co-operation project was initiated in Latin America aimed at improving the physical aspects (as a complement to the clinical issues) of quality assurance in radiotherapy; this ARCAL XXX project (RLA/6/032) was classified as a Model Project of the IAEA. Among the important outcomes of the project were (i) the training of a considerable number of medical physicists in hospitals of the region, (ii) the development of a protocol for quality control procedures, and (iii) the organization of quality audit site visits (to the participant countries) where the implementation in hospitals of the developed quality control procedures is verified. The present publication is the protocol for quality control of the physical aspects of radiotherapy. It contains detailed procedures on what should be ...
2009-06-21
Secure data communication for safeguards implementation
International Nuclear Information System (INIS)
Full text: Secure, reliable and cost-effective communications are becoming an increasingly important tool for safeguards verification. This trend began with the initiation of remote monitoring implementation, where secure and cost effective data communications were required both to satisfy the confidentiality requirements of Member States and in order to meet the rigorous data authenticity requirements which allow the International Atomic Energy Agency (IAEA) to draw credible and independent conclusions. In addition, the implementation of additional protocols and integrated safeguards increases the importance of information (obtained in the course of an inspection, visit, complementary access or design information verification) being analyzed and corroborated with other information sources stored at IAEA Headquarters or Regional Offices, often while the inspector is still on-site. This requires the capability of enabling ...
2006-10-16
International Nuclear Information System (INIS)
Objective: To establish a computer program for rapid calculation of internal committed effective close through inhalation and ingestion pathways under radiological emergency. Methods: Visual Basic 6.0 is used to compile the generic procedures of internal committed effective dose by inhalation and ingestion in IAEA-TECDOC-1162, Generic Procedures for Assessment and Response during a Radiological Emergency. Results: The assessment methodology of internal committed effective dose by inhalation and ingestion under radiological emergency in the report IAEA-TECDOC-1162 can be coded into a computer program. Conclusions: This research provides a rapid method of assessment for internal committed effective dose by inhalation and ingestion under radiological emergency, and it may provide needed dosimetry data for treatment under emergency response. (authors)
2008-08-01
Energy Technology Data Exchange (ETDEWEB)
The IAEA has requested several member states to present their proposal of the application of the Integrated Safeguards (IS) system in their nuclear facilities. This report contains a IS proposal for Finland prepared under the Task FIN C 1264 of The Finnish Support Programme to IAEA Safeguards. The comprehensive safeguards system of the International Atomic Energy Agency (IAEA) has been one of the main tools in the fight against nuclear proliferation since the entry-into-force of the Nuclear Non-proliferation Treaty three decades ago. In the 1990s some of the inherent weaknesses of this so-called traditional safeguards system were revealed first in Iraq and then in North Korea. Therefore, the member states of the LAEA decided to give the Agency additional legal authority in order to make its control system more effective as well as more efficient than before. This was accomplished by the approval of the so-called Model ...
2000-08-01
Clinical application of dosimetry in electron beam therapy
International Nuclear Information System (INIS)
In everyday radiotherapy we must carry out the determination of absorbed dose measurement according to JARP's protocol. We explained an outline of JARP's 1974 and 1986 protocol in electron beam therapy, and mentioned it about the matter that should examined. To use it easily in clinic, a simplified procedure based on precisely to JARP's 1986 protocol is practical, the character of this procedure settles briefly the determination of mean incident energy of electron beams and get ready to table of ionization to absorbed dose conversion factor for various ionization chamber. Also, this procedure almost not influence on the accuracy of determination. We described systematically practical procedure for requisite absorbed dose calculation in a patient in electron beam therapy. (author).
Implementation of integrated safeguards in Nuclear Fuel Plant at Pitesti, Romania
International Nuclear Information System (INIS)
The nuclear activity was conducted for many years in Romania under Traditional Safeguards (TS) and has developed in good conditions the specific nuclear safeguards. Now there is a good opportunity to improve the performance and quality of the safeguards activity and at the same time to increase the accountancy and control of nuclear materials by passing to Integrated Safeguards (IS) implementation. The legal framework is the Law 100/2000 for ratification of the Protocol between Romania and International Atomic Energy Agency (IAEA), additional completion to the Agreement between the Socialist Republic of Romania Government and IAEA relating to safeguards. It is part of the Treaty on the non-proliferation of nuclear weapons published in the Official Gazette no. 3/31 January 1970, and the Additional Protocol published in the Official Gazette no. 295/ 29.06.2000. The first discussion about Integrated ...
2009-10-12
The upgrade of nuclear material accounting system at KAERI
International Nuclear Information System (INIS)
The agreement between the government of Republic Of Korea (ROK) and the IAEA for the application of safeguards was signed and entered into force in 1975. The Additional Protocol (AP) to the Safeguards Agreement between the ROK and the IAEA was signed in 1999 and entered into force on 19 February 2004. Also, Implementation of Integrated Safeguards (IS) was started on 1 July, 2008 after a draw of the broader conclusion. The IAEA provides 2 hours notification for Random Interim Inspection (RII) under IS. For RII, the facility has to prepare the inspection documents in a short time. Therefore, KAERI (Korea Atomic Energy Research Institute) developed a new computerized nuclear material accounting system named KASIS (KAERI Safeguards Information treatment System) to treat the data by on-line for RII. For the efficient IS implementation, KAERI has a plan to upgrade the system to reflect the accounting ...
2010-10-01
International Nuclear Information System (INIS)
The report contains highlights of the achievements of the IAEA Co-ordinated Research programme on Evaluation on the Use of Bulk Reagents for the Production of "9"9Tc_m Radiopharmaceutical and Kits, the participants' summary reports (Argentina, Chile, Greece, India, Indonesia, Japan, Malaysia, Portugal, Russian Federation, Thailand, Uruguay, United States of America), recommended product protocols for five compounds and the participants' recommendations regarding continued support and further directions of co-ordinated research work. Refs, 6 figs, 8 tabs, 6 schemes.
1990-06-24
IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4
Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)
1961-01-01
Energy Technology Data Exchange (ETDEWEB)
This project of law concerns an additional protocol to the agreement of warranties signed on September 22, 1998 between France, the European atomic energy community and the IAEA. This agreement concerns the declaration of all information relative to the R and D activities linked with the fuel cycle and involving the cooperation with a foreign country non endowed with nuclear weapons. These information include the trade and processing of nuclear and non-nuclear materials and equipments devoted to nuclear reactors (pressure vessels, fuel loading/unloading systems, control rods, force and zirconium tubes, primary coolant pumps, deuterium and heavy water, nuclear-grade graphite), to fuel reprocessing plants, to isotope separation plants (gaseous diffusion, laser enrichment, plasma separation, electromagnetic enrichment), to heavy water and deuterium production plants, and to uranium conversion plants. (J.S.)
2002-10-01
Energy Technology Data Exchange (ETDEWEB)
Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the background, were found to be the methods of choice. Pronounced MR image nonuniformity ...
2001-03-01
AIDE: internal dosimetry software.
AIDE (Activity and Internal Dose Estimates) is a software for calculating activities in compartments and committed doses due to occupational exposures, and for performing intake and dose estimates using bioassay data. It has been continuously developed and tested for more than 20 years. Its calculation core has been applied in several situations, like performing all dose estimates due to (137)Cs intakes, which occurred during the Goiania accident in 1987; performing quality assurance of the ICRP Task Group on Dose Calculations regarding calculations of activities in compartments and generation of dose coefficients for adults due to intakes by inhalation, ingestion and injection of several radionuclides; and producing the tables of activities in compartments and dose coefficients using the NCRP Wound Model for the NCRP report. It provides several capabilities like performing calculations using modified Human Respiratory Tract Model parameters for the mechanical transport, blood ...
2008-03-12
Dosimetry audit on the accuracy of 192Ir brachytherapy source strength determinations in Sweden
Energy Technology Data Exchange (ETDEWEB)
The absorbed dose delivered to the patient in brachytherapy is directly proportional to the source strength in terms of the reference air-kerma rate (RAKR). Verification of this quantity by the hospitals is widely recognized as an important part of a quality assurance program. An external audit was performed on behalf of the Secondary Standard Dosimetry Laboratory at the Swedish Radiation Protection Authority (SSI). The aim was to investigate how accurately the source-strength in 192Ir brachytherapy is determined at Swedish hospitals. The SSI reference well-type ion chamber and calibrated equipment were used to measure the RAKR of an 192Ir source in each of the 14 Swedish afterloading units. Comparisons with values determined by vendors and hospitals were made. Agreement in values of RAKR as determined by SSI, hospitals and vendors were in all cases within the +-3% uncertainty (at a coverage factor of k=2), typically guaranteed by the vendors. The good agreement ...
2007-11-15
International Nuclear Information System (INIS)
2010 p. 11 Ukraine Inozemtsev, V. Department of Nuclear Energy, IAEA, Vienna
2010-09-06
The effect of patient shield position on gonad dose during lumbar spine radiography
Energy Technology Data Exchange (ETDEWEB)
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose ...
2010-05-15
The effect of patient shield position on gonad dose during lumbar spine radiography
International Nuclear Information System (INIS)
Background: In an effort to standardise radiological practices in the Republic of Ireland, current legislation states that 'written protocols for every type of standard radiological practice shall be established'. In order to fulfil this requirement the Irish Medical Council recommends the protocols issued by the Commission of European Communitees (CEC) for adoption in the country. Whilst this document does provide good guidance with regard to various radiographic factors, patient shielding instructions are notably ambiguous. The aim of this study was to remove some of this ambiguity by defining the optimal method of positioning patient shielding in antero-posterior (AP) and lateral lumbar spine radiographic examinations. These projections were chosen on the basis of their area of coverage being in close to and in some cases including the reproductive organs. They also represent the highest source of collective population dose of any ...
2010-05-01
Energy Technology Data Exchange (ETDEWEB)
Faced with increasing indications for the use of iodine-131 labelled lipiodol in the treatment of hepatocellular carcinoma (HCC), it appears essential to develop an individualized dosimetrY so we can predict the potential effectiveness of this treatment and adjust the activity to be injected. We developed a dosimetric protocol based on imagery and dedicated to calculation of the tumoral dose during the treatment of hepatocellular carcinoma by iodine-131 labelled lipiodol. This concept was developed on a SPECT- CT gantry, and integrates corrections for the phenomena of attenuation, diffusion and dead time. The dose is calculated according to the formalism proposed by the Medical Internal Radiation Dose Committee (MIRD). This protocol was applied to a series of 41 patients in the framework of a retrospective study. The results obtained in terms of biodistribution are compatible with previously published data. The total ...
2006-12-15
Legal Analysis of the Korea Radioactive Waste Management Act in the aspect of IAEA Principles
International Nuclear Information System (INIS)
According to the Principles of Radioactive Waste Management, the IAEA SAFETY SERIES NO-111-F, IAEA declared 9 doctrines. The IAEA advised a country that operates nuclear power plant to adopt the principles. As a member of the IAEA, Korea has also discussed about a unified policy and enacting law for radioactive waste management to follow the doctrines. This study analyzed the recently enacted Korea Radioactive Waste Management Act and verified whether the Act successfully follows the doctrine or not
2009-05-01
International Nuclear Information System (INIS)
This Publications Catalogue lists all sales publications of the IAEA published in 2004, 2005 and forthcoming in 2006. Most IAEA publications are issued in English, some are also available in Arabic, Chinese, French, Russian or Spanish. This is indicated at the bottom of the book entry. A complete listing of all IAEA priced publications is available on the IAEA's web site: http://www.iaea.org/books
Concepts in radiation protection
International Nuclear Information System (INIS)
This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the radiation protection, especially of the 'public' where the dose limit diminished by a factor of five relative to the earlier edition. The new value of dose limit for ...
1996-01-01
Optimal protocols for nonlocality distillation
International Nuclear Information System (INIS)
Forster et al. recently showed that weak nonlocality can be amplified by giving the first protocol that distills a class of nonlocal boxes (NLBs) [Phys. Rev. Lett. 102, 120401 (2009)] We first show that their protocol is optimal among all nonadaptive protocols. We next consider adaptive protocols. We show that the depth-2 protocol of Allcock et al. [Phys. Rev. A 80, 062107 (2009)] performs better than previously known adaptive depth-2 protocols for all symmetric NLBs. We present a depth-3 protocol that extends the known region of distillable NLBs. We give examples of NLBs for which each of the Forster et al., the Allcock et al., and our protocols perform best. The understanding we develop is that there is no single optimal protocol for NLB distillation. The choice of which ...
2010-10-01
The Montreal protocol: A dynamic agreement for protecting the ozone layer
Energy Technology Data Exchange (ETDEWEB)
The Montreal Protocol provides the international community with an effective equitable and dynamic mechanism for protecting the ozone layer. The paper uses the Protocol's negotiating history to describe how and why agreement on a particular issue was reached and provides an in-depth analysis of the Protocol's most innovative provisions. The paper discusses international implementation of the Protocol. It concludes with a brief description of recent developments leading up to the Protocol's possible modification in June 1990. (14 refs.).
1990-04-01
Energy Technology Data Exchange (ETDEWEB)
The International Atomic Energy Agency (IAEA) plans to use the Common Criteria, as the tool for developing graded and measurable evaluation criteria for information technology (IT) in safeguards systems in facilities subject to IAEA inspection. In their draft paper [ITSECSES] the IAEA defines a three-tiered Vulnerability Assessment Level (VAL) scheme. Each increased VAL level (1-3) defines additional and more stringent security and security-related requirements for the system developer, the system evaluator (assessor or authenticator), and for the IAEA. When all parties meet all requirements for a particular VAL level, IAEA has a measurable degree of confidence in the secure and proper operation of an IT system.
2001-12-06
Simple Proof of Security of the BB84 Quantum Key Distribution Protocol
Energy Technology Data Exchange (ETDEWEB)
We prove that the 1984 protocol of Bennett and Brassard (BB84) for quantum key distribution is secure. We first give a key distribution protocol based on entanglement purification, which can be proven secure using methods from Lo and Chau's proof of security for a similar protocol. We then show that the security of this protocol implies the security of BB84. The entanglement purification based protocol uses Calderbank-Shor-Steane codes, and properties of these codes are used to remove the use of quantum computation from the Lo-Chau protocol. (c) 2000 The American Physical Society.
2000-07-10
Regulation of red mud from the alumina industry in Australia
International Nuclear Information System (INIS)
English 2005 p. 52-59 International Atomic Energy Agency (IAEA) Collier,
2002-09-23
Pretargeted radioimmunotherapy in tumored mice using an in vivo {sup 212}Pb/{sup 212}Bi generator
Energy Technology Data Exchange (ETDEWEB)
Objective: Pretargeting is the concept that combines optimal delivery of the antibody and rapid capture and elimination of the radioactivity. In this study, we evaluated the potential of antibody pretargeting to enable the tumor-targeting {sup 212}Pb for in vivo generation of {sup 212}Bi for {alpha} particle radiotherapy. Methods: The {sup 212}Pb/{sup 212}Bi chelate of DOTA-biotin, as well as their {gamma}-emitting analogues, {sup 203}Pb and {sup 205}Bi, was prepared and characterized. The radiolabeled compounds were injected in animals for evaluation of tumor targeting and normal tissue uptake and retention. In the pretargeting protocol, injection of 400 {mu}g of NR-LU-10 antibody-streptavidin conjugate was given at t=0 h, then 100 {mu}g of N-acetyl-galatosamine-biotin clearing agent was injected at t=20-24 h; finally, 1 {mu}g of {sup 212}Pb/{sup 212}Bi-DOTA-biotin was injected 6 h later. Results: Both {sup 203}Pb and {sup 205}Bi-DOTA-biotin were stable for at ...
2005-10-01
International Nuclear Information System (INIS)
Selected neutron reaction nuclear data libraries and photon-atomic interaction cross section libraries for elements of interest to the IAEA's program on Fusion Evaluated Nuclear Data Library (FENDL) have been processed into MATXSR format using the NJOY system on the VAX4000 computer of the IAEA. This document lists the resulting multigroup data libraries. All the multigroup data generated are available cost-free upon request from the IAEA Nuclear Data Section. (author). 9 refs.
Energy Technology Data Exchange (ETDEWEB)
In order to consider some procedures to prevent errors in radiotherapy based in learned lessons of accidental expositions and in accordance with information contained in international reports elaborated by International Atomic Energy Agency (IAEA) and of the data base availability by the European group Radiation Oncology Safety Information System (ROSIS) on the events, a research of the occurred errors was performed. For the evaluation of the incidents a data base based in the ROSIS and added plus a parameter was created 'type of error'. All the stored data make possible the evaluation of the 839 incidents in terms of frequency of the type of error, the process of detention, the number of reached patients and the degree of severity. Of the 50 types of found errors, the type of error more frequently was 'incorrect treatment coordinate', confirmed with the data of literature and representing 28,96 por cent of the total of the ...
2007-07-01
Evaluating noncancer effects of trichloroethylene: dosimetry, mode of action, and risk assessment.
UK PubMed Central (United Kingdom)
Alternatives for developing chronic exposure limits for noncancer effects of trichloroethylene (TCE) were evaluated. These alternatives were organized within a framework for dose-response assessment--exposure:dosimetry...Full Text Available
2000-05-01
Advanced applications of water cooled nuclear power plants
International Nuclear Information System (INIS)
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached 83%; - Growing energy needs: All forecasts project increases in ...
2007-07-01
Advanced applications of water cooled nuclear power plants
International Nuclear Information System (INIS)
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached 83%; - Growing energy needs: All forecasts project increases in ...
1996-07-21
Advanced applications of water cooled nuclear power plants
International Nuclear Information System (INIS)
By August 2007, there were 438 nuclear power plants (NPPs) in operation worldwide, with a total capacity of 371.7 GW(e). Further, 31 units, totaling 24.1 GW(e), were under construction. During 2006 nuclear power produced 2659.7 billion kWh of electricity, which was 15.2% of the world's total. The vast majority of these plants use water-cooled reactors. Based on information provided by its Member States, the IAEA projects that nuclear power will grow significantly, producing between 2760 and 2810 billion kWh annually by 2010, between 3120 and 3840 billion kWh annually by 2020, and between 3325 and 5040 billion kWh annually by 2030. There are several reasons for these rising expectations for nuclear power: - Nuclear power's lengthening experience and good performance: The industry now has more than 12 000 reactor years of experience, and the global average nuclear plant availability during 2006 reached 83%; - Growing energy needs: All forecasts project increases in ...
2007-11-23
International Nuclear Information System (INIS)
... 5 360 p. RADIATION PROTECTION AND DOSIMETRY fire fighting occupational
Hanford Internal Dosimetry Program Manual, PNL-MA-552
Energy Technology Data Exchange (ETDEWEB)
This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.
2009-09-24
Theoretical Basis of Protocols for Seed Storage
UK PubMed Central (United Kingdom)
The protocols presently established for optimum seed storage do not account for the chemical composition of different seed species, the physiological status of the seed, and the physical status of water...Full Text Available
1990-11-01
International Nuclear Information System (INIS)
Full text: The ITWG was first formed in 1995 for the purpose of fostering international cooperation for combating illicit trafficking of nuclear materials. The initial focus for the ITWG was on the development of nuclear forensics to help answer attribution questions regarding nuclear materials of unknown origin. More recently, the ITWG has also expanded its focus to include detection of nuclear materials during transit. This paper presents some of the key developments by this group and their potential impact for combating nuclear smuggling. The initial focus of the ITWG was to write a status report on international cooperation on nuclear smuggling forensic analysis. This 26-page report summarized previous work on nuclear forensics and gave an initial analysis on prioritizing techniques and methods for forensic analysis regarding source and route attribution. This report was submitted to the G-8 countries, and shortly thereafter, nuclear forensics was endorsed at the Moscow Summit in ...
2002-10-21
Energy Technology Data Exchange (ETDEWEB)
The quality insurance in radiotherapy in the frame of highly complex technical process as Intensity modulated radiotherapy (I.M.R.T.) needs independent control of the delivered dose to the patient. Actually, up to now, most of the radiotherapy treatments rely only on computed dosimetry through a rather complicated series of linked simulation tool. This dosimetry approach requires also qualified treatment means based on cautious quality insurance procedures. However, erroneous parameters could be difficult to detect and systematical errors could happen leading to radiotherapy accidents. In this context, in vivo dosimetry has a critical role of final control of the delivered dose. As many beam incidences and ports are used for any photon therapy treatment, external control could be very tedious and time consuming. Therefore, innovations are needed for in vivo dosimetry to provide ergonomic and efficient ...
2009-06-15
Energy Technology Data Exchange (ETDEWEB)
It was agreed that both of the Republic Of Korea (ROK) and the International Atomic Energy Agency (IAEA) cooperate with the new approach using the Unattended Monitoring Systems (UMS), the mailbox declaration and the short notice inspections, which can decrease the agency inspection efforts and operator' s burden. As a result of the positive cooperation of ROK for applying new approach, the IAEA could accomplish a successful implementation of new safeguards approach during last transfer campaigns at Wolsung site. As of the end of Feb. 2007, the IAEA installed the UMS at Wolsung units 2, 3 and 4. The transfer campaigns at Wolsung units 2 and 4 are performing from April, 2007. The IAEA will install the UMS at Wolsung unit 1 by the end of 2007. Then agency will inspect all of transfer campaign at Wolsung units by using new approach with UMS, mailbox declaration and SNI. It is based on the SSAC full ...
2007-07-01
International Nuclear Information System (INIS)
It was agreed that both of the Republic Of Korea (ROK) and the International Atomic Energy Agency (IAEA) cooperate with the new approach using the Unattended Monitoring Systems (UMS), the mailbox declaration and the short notice inspections, which can decrease the agency inspection efforts and operator' s burden. As a result of the positive cooperation of ROK for applying new approach, the IAEA could accomplish a successful implementation of new safeguards approach during last transfer campaigns at Wolsung site. As of the end of Feb. 2007, the IAEA installed the UMS at Wolsung units 2, 3 and 4. The transfer campaigns at Wolsung units 2 and 4 are performing from April, 2007. The IAEA will install the UMS at Wolsung unit 1 by the end of 2007. Then agency will inspect all of transfer campaign at Wolsung units by using new approach with UMS, mailbox declaration and SNI. It is based on the SSAC full ...
2007-05-10
The U.S. Support Program to IAEA Safeguards - How It Works
Energy Technology Data Exchange (ETDEWEB)
The U.S. Support Program to International Atomic Energy Agency (IAEA) Safeguards (USSP) was established in 1977 to transfer US technology and expertise to assist the IAEA Department of Safeguards because its limited budget and scope would not allow for R&D activities and the procurement of specialized or customized equipment. Over the years, the USSP and the Department of Safeguards have worked together continuously to develop and improve processes for requesting, selecting, and managing projects that support the Safeguards verification mission. This paper will discuss the main USSP processes for accepting and processing Safeguards requests, and managing and reporting task progress.
2008-07-13
British Library Electronic Table of Contents (United Kingdom)
We performed a randomized trial to compare IVF outcomes in 54 poor responder patients undergoing a microdose leuprolide acetate (LA) protocol or a GnRH antagonist protocol incorporating a luteal phase E2 patch and GnRH antagonist in the preceding menstrual cycle. Cancellation rates, number of oocytes retrieved, clinical pregnancy rates (PR), and ongoing PRs were similar between the two groups.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Based on the enhanced cooperation between Republic of Korea (ROK) and International Atomic Energy Agency (IAEA), IAEA installed new safeguards equipment (Unattended Monitoring System, UMS) at Wolsung unit 2 on January, 2005. The UMS was utilized in parallel with traditional human surveillance during the transfer campaign of Wolsung unit 2 (7 March - 22 July). Installation of UMS at all Wolsung units will be decided on the basis of the result of this test. The transfer campaign with UMS at Wolsung units 2 and 4 was started from September 1, 2006 at the same time. Implementation of UMS to the transfer campaign in Wolsung site will be considerably reduced the IAEA's inspection effort and burden of operator.
2006-07-01
International Nuclear Information System (INIS)
Based on the enhanced cooperation between Republic of Korea (ROK) and International Atomic Energy Agency (IAEA), IAEA installed new safeguards equipment (Unattended Monitoring System, UMS) at Wolsung unit 2 on January, 2005. The UMS was utilized in parallel with traditional human surveillance during the transfer campaign of Wolsung unit 2 (7 March - 22 July). Installation of UMS at all Wolsung units will be decided on the basis of the result of this test. The transfer campaign with UMS at Wolsung units 2 and 4 was started from September 1, 2006 at the same time. Implementation of UMS to the transfer campaign in Wolsung site will be considerably reduced the IAEA's inspection effort and burden of operator.
2006-11-02
International Nuclear Information System (INIS)
English Sep 2008 p. 56-57 International Atomic Energy Agency (IAEA)
2008-09-01
Nuclear Power Reactors in the World. 2009 Ed
International Nuclear Information System (INIS)
This is the twenty-ninth edition of Reference Data Series No. 2, Nuclear Power Reactors in the World, which is published once per year, and presents the most recent reactor data available to the IAEA. It contains the following summarized information: - General information as of the end of 2008 on power reactors operating or under construction, and shut down; - Performance data on reactors operating in the Agency's Member States, as reported to the IAEA. The IAEA's Power Reactor Information System (PRIS) is a comprehensive data source on nuclear power reactors in the world. It includes specification and performance history data of operating reactors as well as reactors under construction or reactors being decommissioned. PRIS data are collected by the IAEA through the designated national correspondents of Member States
WLUP3.0, 69 and 172 Group Cross Section Libraries for WIMS
International Nuclear Information System (INIS)
Description or function: WLUP contains validated WIMS-D formatted cross section libraries in 69 and 172 energy group structures for nuclear reactor calculations. Materials from recently released evaluated nuclear data libraries are included. The NJOY nuclear data processing system was applied for generating the cross section files following the models and conventions built into the WIMS-D lattice code. The relevant features for the WIMS users are: - Energy group structures: 69 and 172 energy groups. - List of materials: WIMS ID, general information, source of data. - Cross sections: 69 and 172 group plots. - Resonance data: WIMS ID, temperature, background cross sections. - Goldstein-Cohen factors: Goldstein-Cohen lambda values. - Thermal scattering data: thermal scattering laws and P1 matrixes. - Fission spectrum: fission spectrum data. - Burnup data: burnup chains. - Fission product yields: fission yield tables. - Pseudo lumped fission product: Description of pseudo fission product. ...
International Nuclear Information System (INIS)
The diagnostic accuracy is compared of the dual-isotope protocol and the conventional "2"0"1Tl protocol, for detection of the coronary artery disease (CAD) using data on a total of 69 patients after myocardial infarction (MI). The "2"0"1Tl protocol was used to examine 44 patients, the dual-isotope protocol was used with 25 patients. All patients were examined by coronarography; a narrowing of the artery by more than 50 % was considered significant for CAD. The sensitivity, specificity and diagnostic accuracy was 97.7 %, 100 % and 97.7 % resp. for the "2"0"1Tl protocol, and 95.2 %, 75 % and 92 % resp. for the dual-isotope protocol. A higher diagnostic accuracy of the dual-isotope protocol has not been proven, and the "2"0"1Tl protocol continues to be used for examinations of patients after MI
1998-08-01
Acceptance testing in digital systems of mammography. Protocols applicability
International Nuclear Information System (INIS)
Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the ...
Overview of IAEA year 2000 activities in the Department of Safeguards
International Nuclear Information System (INIS)
The IAEA Department of Safeguards established a project in 1996 for the year 2000 (Y2K) conversion activities. This project covered assessment, conversion and testing of the software applications, instrument evaluation software, embedded systems and Personal Computer (PC) hardware attached to various equipment. Significant progress has been made in converting the applications and instruments to be year 2000 compliant. At the same time Member states have made an effort as well in converting the systems used jointly at the facilities
1999-02-01
Korea-IAEA Unattended Safeguards Approach on the Spent Fuel Transfer to Dry Storage in Wolsung NPP
Energy Technology Data Exchange (ETDEWEB)
The field trial of an unattended monitoring system for SF transfer verification ended in June 2005. The system is aiming to improve the safeguards measures applied during SF transfers and reduce inspection effort currently required by the Operator, NNCA and the IAEA. They were reviewed based on its technical performance and other issues in this paper.
2006-07-01
Korea-IAEA Unattended Safeguards Approach on the Spent Fuel Transfer to Dry Storage in Wolsung NPP
International Nuclear Information System (INIS)
The field trial of an unattended monitoring system for SF transfer verification ended in June 2005. The system is aiming to improve the safeguards measures applied during SF transfers and reduce inspection effort currently required by the Operator, NNCA and the IAEA. They were reviewed based on its technical performance and other issues in this paper.
2006-05-25
IAEA Nuclear Security Programme Combating Nuclear Terrorism
International Nuclear Information System (INIS)
IAEA Plans of activities include, General Conference in September 2001 which reviewed activities relevant to preventing nuclear terrorism and proposed master plan. The Board of Governors approved new Nuclear Security Plan for the next four years. Three activity areas are; - needs assessment, analysis and coordination, prevention and detection and response.
2010-05-10
Hungarian experience in using the IAEA planning methodologies
International Nuclear Information System (INIS)
The Hungarian Power Companies Ltd. has been using the IAEA planning methodologies since 1985 when it acquired the WASP model. Since then this model has been applied on a regular basis to determine the least cost expansion plan of the power generating system of the country. This report describes this experience as well as the application of the WASP model for other types of studies. (author).
1997-09-01
VOLUME I11 IMISSION SYSTEM PERFORMANCE - NASA Technical Report ...
Nov 8, 2010 ... Ihring Mission 11, the radiation dosimetry measurement system functioned normally and provided data on the Earth's trapped radiation belts ...
Luminescence dating of marine and fluvial sediments ... - GCMD - NASA
INAA (instrumental neutron activation analysis) analyses have been made of subsamples of each OSL (Optically stimulated luminescence) sample, for dosimetry ...
Correlation between particle size, in vivo particle persistence, and lung injury.
UK PubMed Central (United Kingdom)
Dosimetry parameters such as deposition, clearance, retention, and translocation and dissolution of inhaled particles in and to different lung compartments may be important for the persistence of particles...Full Text Available
1994-10-01
British Library Electronic Table of Contents (United Kingdom)
Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...
2011-01-01
What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography?
International Nuclear Information System (INIS)
Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second phase) used the ...
2010-08-01
Producing the future: a powerful security standard and new Internet protocols are among the innovations being hatched at MIT(Q & A)(Interview)
2004-01-01
Energy Technology Data Exchange (ETDEWEB)
This paper describes the needs, reasoning, approaches, and technical details to establish a practical accelerated weathering test (AWT) protocol for indoor testing of the photothermal stability of encapsulation materials and encapsulated solar cells and minimodules.
2000-01-01
Vacuum Packaging for Microelectromechanical Systems ...
... more than expected in developing a unique bond strength measurement protocol that is important for a wide range of bond strength measurements. ...
2002-10-01
INL Advanced Radiotherapy Research Program Annual Report 2004
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the activities and major accomplishments for the Idaho National Laboratory Advanced Radiotherapy Research Program for calendar year 2004. Topics covered include boron analysis in biological samples, computational dosimetry and treatment planning software development, medical neutron source development and characterization, and collaborative dosimetry studies at the RA-1 facility in Buenos Aires, Argentina.
2005-06-01
Nuclear forensics support. Reference manual
International Nuclear Information System (INIS)
Illicit trafficking of nuclear and other radioactive material has been an issue of concern since the first seizures in the early 1990s. By the end of 2004 Member States had confirmed 540 cases, while about another 500 remain unconfirmed. Most of the confirmed cases have a criminal dimension, even if they were not for known terrorist purposes. The attacks of September 2001 in the USA dramatically emphasized the requirement for the enhanced control and security of nuclear and other radioactive material. In response to a resolution by the IAEA General Conference in September 2002 the IAEA has adopted an integrated approach to protection against nuclear terrorism. This brings together IAEA activities concerned with the physical protection of nuclear material and nuclear installations, nuclear material accountancy, detection and response to illicit nuclear trafficking, the security and safety of radioactive sources, emergency ...
International Nuclear Information System (INIS)
The purpose of this study was to compare a double freeze-thaw protocol to a triple freeze-thaw protocol for pulmonary cryoablation utilizing an in vivo porcine lung model. A total of 18 cryoablations were performed in normal porcine lung utilizing percutaneous technique with 9 each in a double- (10-5-10) and triple-freeze (3-3-7-7-5) protocol. Serial noncontrast CT images were obtained during the ablation. CT imaging findings and pathology were reviewed. No imaging changes were identified during the initial freeze cycle with either protocol. However, during the first thaw cycle, a region of ground glass opacity developed around the probe with both protocols. Because the initial freeze was shorter with the triple freeze-thaw protocol, the imaging findings were apparent sooner with this protocol (6 vs. 13 min). Also, despite a shorter total ...
2010-12-01
Creating Open Digital Library Using XML Implementation of OAi-PMH Protocol at CERN
This article describes the implementation of the OAi-PMH protocol within the CERN Document Server (CDS). In terms of the protocol, CERN acts both as a data provider and service provider and the two core applications are described. The application of XML Schema and XSLT technology is emphasized.
2002-01-01
An architecture for device independent interfacing
Energy Technology Data Exchange (ETDEWEB)
Achieving device independence for software applications is required for all but a small number of critical real time applications. Device independence is achieved by establishing protocols and building protocol interpreters for the specific devices. Data structures containing pointers to functions provide a flexible architecture for implementing protocol translation. 3 refs., 5 figs.
1990-01-01
International Nuclear Information System (INIS)
Nuclear forensics can provide information about the history, intended use and potentially the origin of nuclear or radioactive material. For these reasons, it is an important tool for improving nuclear security and combating illicit trafficking of nuclear and other radioactive materials. The IAEA is currently working on enhancing knowledge, techniques, procedures and cooperation in the field of nuclear forensics. Some of the work currently being undertaken by the IAEA includes the development of a five day training workshop on basic methods for radiological crime scene activities, to ensure adequate control of evidence, including for nuclear forensics purposes, a coordinated research project on the application of nuclear forensics in illicit trafficking, and a proposal for international cooperation with nuclear forensics databases and the development of guidelines for establishing databases. Nuclear forensics will continue to be an important ...
INTRINSIC DOSIMETRY: A POTENTIAL NEW TOOL FOR NUCLEAR FORENSICS INVESTIGATIONS
International Nuclear Information System (INIS)
Thermoluminescence (TL) dosimetry was used to measure dose effects on the raw stock material of borosilicate container glass from different geographical locations. Effects were studied at times up to 60 days post-irradiation at doses from 0.15 to 20 Gy. The minimum detectable dose using this technique was estimated to be 0.15 Gy which is roughly equivalent to a 24 hr irradiation 1 cm from a 50 ng source of 60Co. Two peaks were identified in the TL glow curve, a relatively unstable peak around 125 C and a more stable peak around 225 C. Differences in TL glow curve shape and intensity were also observed for the glasses from different geographical origins. We investigate radiation induced defects in glass to further develop the technique of intrinsic dosimetry - the measurement of the total absorbed dose received by the walls of a container holding radioactive material. Intrinsic dosimetry is intended to be used as an ...
2010-07-11
International Nuclear Information System (INIS)
The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an ...
2011-01-01
Nuclear raw materials: Developing resources through technical co-operation
International Nuclear Information System (INIS)
This article presents an overview of the IAEA's technical co-operation activities in the field of nuclear raw materials, particularly looking at recent developments and trends influencing future directions
1993-09-01
IAEA RESEARCH CONTRACTS. THIRD ANNUAL REPORT. Technical Reports Series No. 16
Brief summaries of all final reports relating to contracts that were completed during 1962 are presented. 20 summaries are included. (P.C.H.)
1963-01-01
End user needs for enhanced IAEA Safeguards Information Management Capabilities
International Nuclear Information System (INIS)
The International Atomic Energy Agency is undertaking a program for strengthening its safeguards on the recognition that safeguards must give assurance not only of the non-diversion of declared material or that declared facilities are not being misused, but also of the absence of any undeclared nuclear activities in States which have signed comprehensive safeguards agreements with the Agency. The IAEA has determined that the detection of undeclared nuclear activities and the creation of confidence in the continuing peaceful use of declared material and facilities is largely dependent on more information being made available to the Agency and on the capability of the Agency to make more effective use of this additional information, as well as existing information.
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of targeted radionuclide therapy and the various components and ...
2003-01-01
Personal nuclear accident dosimetry at Sandia National Laboratories
Energy Technology Data Exchange (ETDEWEB)
DOE installations possessing sufficient quantities of fissile material to potentially constitute a critical mass, such that the excessive exposure of personnel to radiation from a nuclear accident is possible, are required to provide nuclear accident dosimetry services. This document describes the personal nuclear accident dosimeter (PNAD) used by SNL and prescribes methodologies to initially screen, and to process PNAD results. In addition, this report describes PNAD dosimetry results obtained during the Nuclear Accident Dosimeter Intercomparison Study (NAD23), held during 12-16 June 1995, at Los Alamos National Laboratories. Biases for reported neutron doses ranged from -6% to +36% with an average bias of +12%.
1996-09-01
TLD assessment of mouse dosimetry during microCT imaging
UK PubMed Central (United Kingdom)
Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available
2008-09-01
Energy Technology Data Exchange (ETDEWEB)
A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).
1997-04-01
Revised neutron dosimetry results for the MOTA-2A experiment in FFTF
Energy Technology Data Exchange (ETDEWEB)
Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.
1994-09-01
Energy Technology Data Exchange (ETDEWEB)
Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)
1980-01-01
Photon dosimetry using plastic scintillators in pulsed radiation fields
Energy Technology Data Exchange (ETDEWEB)
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is ...
2007-04-01
International Nuclear Information System (INIS)
This report describes a neutron fluence assessment performed for the Kori Unit 3 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1 MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. After Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 3 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel Neutron Dosimetry has been evaluated at the conclusion of Cycle 17
2006-06-13
EPR dosimetry in chemically treated fingernails
UK PubMed Central (United Kingdom)
By using EPR measurements of radiation-induced radicals it is possible to utilize human fingernails to estimate radiation dose after-the-fact. One of the potentially limiting factors in this...Full Text Available
2007-08-01
UK PubMed Central (United Kingdom)
Purposes1. To determine the optimal pelvic nodal clinical target volume for post-operative treatment of endometrial cancer. 2. To compare the DVH of different treatment planning...Full Text Available
1,3-Butadiene: linking metabolism, dosimetry, and mutation induction.
UK PubMed Central (United Kingdom)
There is increasing concern for the potential adverse health effects of human exposures to chemical mixtures. To better understand the complex interactions of chemicals within a mixture, it is essential...Full Text Available
1994-11-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents the history and objectives of the development of a standard method for the measurement of organic contaminants in biomass producer gases. Recently, a project with that title has started in the European 5{sup th} Framework Programme. The structure of this project with acronym 'Tar Protocol' is also described in this paper. The project is performed by 17 partners and continues earlier work initiated by IEA (International Energy Agency), DoE (Department of Energy) and EU (European Union) in 1998. The project aims to combine two draft Protocols that resulted from this earlier work. The Tar Protocol will be developed for accurate measurement of organic contaminants ('tars') over a large range of concentrations (1 mg/Nm{sup 3} to 100 g/Nm{sup 3}) and conditions (0 - 900 deg C; 0.9 - 60 bars). Besides, a particulate concentration will be determined too. Together with the ...
2000-06-01
Energy Technology Data Exchange (ETDEWEB)
The Advanced Simulation and Computing (ASC) Distance Computing (DisCom) Wide Area Network (WAN) is a high performance, long distance network environment that is based on the ubiquitous TCP/IP protocol set. However, the Transmission Control Protocol (TCP) and the algorithms that govern its operation were defined almost two decades ago for a network environment vastly different from the DisCom WAN. In this paper we explore and evaluate possible modifications to TCP that purport to improve TCP performance in environments like the DisCom WAN. We also examine a much newer protocol, SCTP (Stream Control Transmission Protocol) that claims to provide reliable network transport while also implementing multi-streaming, multi-homing capabilities that are appealing in the DisCom high performance network environment. We provide performance comparisons and recommendations for continued development that will lead to ...
2005-06-01
Distributed MAC Protocol Supporting Physical-Layer Network Coding
Physical-layer network coding (PNC) is a promising approach for wireless networks. It allows nodes to transmit simultaneously. Due to the difficulties of scheduling simultaneous transmissions, existing works on PNC are based on simplified medium access control (MAC) protocols, which are not applicable to general multi-hop wireless networks, to the best of our knowledge. In this paper, we propose a distributed MAC protocol that supports PNC in multi-hop wireless networks. The proposed MAC protocol is based on the carrier sense multiple access (CSMA) strategy and can be regarded as an extension to the IEEE 802.11 MAC protocol. In the proposed protocol, each node collects information on the queue status of its neighboring nodes. When a node finds that there is an opportunity for some of its neighbors to perform PNC, it notifies its corresponding neighboring nodes and initiates the ...
2011-01-01
An Empirical Analysis of Internet Protocol Version 6 (IPv6)
Although the current Internet Protocol known as IPv4 has served its purpose for over 20 years, its days are numbered. With IPv6 reaching a mature enough level, there is a need to evaluate the performance benefits or drawbacks that the new IPv6 protocol will have in comparison to the well established IPv4 protocol. Theoretically, the overhead between the two different protocols should be directly proportional to the difference in the packet's header size, however according to our findings, the empirical performance difference between IPv4 and IPv6, especially when the transition mechanisms are taken into consideration, is much larger than anticipated. We first examine the performance of each protocol independently. We then examined two transition mechanisms which perform the encapsulation at various points in the network: host-to-host and router-to-router (tunneling). Our experiments ...
2004-01-01
Tritium bioassay and dosimetry at a CANDU reactors
Energy Technology Data Exchange (ETDEWEB)
Tritium dose management is an important aspect of the radiation protection program at CANDU type reactor sites. This paper describes the bioassay and dosimetry of tritium at CANDU reactor sites, especially for Wolsung Nuclear Power Plant. It presents a compilation of information drawn from published papers, technical reports, international and national guidelines as well as practical experience both in Korean and Canadian CANDU Nuclear Power Plants. The implementation of this program would provide a technical basis for calculations and records should be of acceptable quality and should meet overall radiation protection program objectives.
1996-07-01
Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)
Energy Technology Data Exchange (ETDEWEB)
Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
The recent definition of a postulated thermal shock accident followed promptly by system repressurization, termed an overcooling or pressurized thermal shock accident, has set a large analysis and research effort into motion. The essential elements are concerned with defining the accident transients, evaluating the instrumentation and controls that cause the postulated accidents, and evaluating the metallurgical and structural mechanics aspects of the reactor vessel with respect to its failure potential. This paper poses the question faced by the Nuclear Regulatory Commission (NRC) for the vessel steel embrittlement, annealing, and surveillance dosimetry facets of this postulated accident and provides information on our plans for study of this problem as well as current status.
1981-10-01
Multicellular level dosimetry and low dose rate effects
International Nuclear Information System (INIS)
Building on the concepts of MIRD methods described by Webber, Watson and others at this Symposium on the Dosimetry of Administered Radionuclides, we will now consider how to apply these principles to several experimentally based open-quote macroclose quotes and multicellular models. Specifically, methods to calculate absorbed dose using different types of particulate emission (alpha, beta) with a variety of antibody carriers (IgG, F(ab')_2, Fab) for radioimmunotherapy (RIT) will be reviewed. Additionally, a discussion of direct measurement methods at the multicellular level will reveal the problems of tumor absorbed dose heterogeneity when applied to animal and clinical studies.
1989-09-21
Energy Technology Data Exchange (ETDEWEB)
Background: The difficulty of directly measuring cellular dose is a significant obstacle to application of target tissue dosimetry for nanoparticle and microparticle toxicity assessment. As a consequence, the target tissue paradigm for dosimetry and hazard assessment of nanoparticles has largely been ignored in favor of using metrics of exposure (e.g. ?g particle/mL culture medium, particle surface area/mL, particle number/mL). We have developed a computational model of solution particokinetics (sedimentation, diffusion) and dosimetry for non-interacting spherical particles and their agglomerates in monolayer cell culture systems. Particle transport to cells is calculated by simultaneous solution of Stokes Law (sedimentation) and the Stokes-Einstein equation (diffusion). Results: The In vitro Sedimentation, Diffusion and Dosimetry model (ISDD) was tested against measured transport rates or cellular ...
2010-11-30
Dual-field rotational (DFR) technique for total-skin electron-beam therapy (TSEBT)
Energy Technology Data Exchange (ETDEWEB)
Comparison of dosimetry measured in a noncylindrical Rando-Alderson phantom by two-field, four-field, and six-field total-skin electron-beam therapy (TSEBT) techniques with our dual-field rotational (DFR) technique reveals a superior dosimetry for the latter. Our technique of dual-field rotational DFR-TSEBT is described in detail, and its advantages and indications for the primary management of cutaneous T-cell lymphoma (CTCL) and Kaposi's sarcoma (KS) are discussed.
1987-08-01
International Nuclear Information System (INIS)
The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)
1998-01-01
Coherent state quantum key distribution with multi letter phase-shift keying
International Nuclear Information System (INIS)
We present a protocol for quantum key distribution using discrete modulation of coherent states of light. Information is encoded in the variable phase of coherent states which can be chosen from a regular discrete set ranging from binary to continuous modulation similar to phase-shift keying in classical communication. Information is decoded by simultaneous homodyne measurement of both quadratures and requires no active choice of basis. The protocol utilizes either direct or reverse reconciliation both with and without postselection. We analyze the security of the protocol and show how to enhance it by the optimal choice of all variable parameters of the quantum signal.
2010-05-01
Vascular Effects of Photodynamic and Pulsed Dye Laser Therapy Protocols
UK PubMed Central (United Kingdom)
Background and ObjectivePulsed dye laser (PDL) treatment of cutaneous vascular lesions is associated with variable and unpredictable efficacy. Thus, alternative treatment...Full Text Available
2008-11-01
Energy Technology Data Exchange (ETDEWEB)
This report provides a user's manual for PROTOCOL, a comprehensive coupled kinetic/equilibrium computer program for analyzing the dissolution reactions of solids with aqueous solutions, specifically applied to the potential corrosion of vitrified nuclear waste by groundwater. The capabilities and available options are summarized as well as instructions for setting up and running problems. Also described in this report and included in the PROTOCOL software package are MASTER, a master file of species thermodynamic data, MANEQL, a preprocessor program and POSTP, a postprocessor. POSTP provides offline plotting using the CRAY-1 DISSPLA 9.0 graphics library. PROTOCOL is operational on the CDC-7600 and CRAY-1 computers at the Lawrence Livermore National Laboratory. 7 references, 10 figures, 2 tables.
1984-10-01
The political and economic costs of a fully verifiable Kyoto Protocol
Energy Technology Data Exchange (ETDEWEB)
Until now policy makers and researchers considered the problem of uncertainty and verification to be of minor importance for the Kyoto process. However, the first studies that recently appeared on uncertainty estimation of carbon accounting reveal that uncertainties of the reported emissions on the country level are large. In an environment of such large uncertainties, verification of emission reductions must be viewed as a crucial mechanism to secure the very functioning of the Protocol. The paper provides a set of tools to strategically deal with the problem of uncertainty and verification under the Kyoto Protocol. This is done by: providing an overview of the instruments to deal with verification (no-, trend-, level- and top-down/bottom-up verification under PCA and FCA); compute costs scenarios for those instruments under various flexibility scenarios; and providing a short discussion on practical steps and crucial decisions to be made that ...
2000-11-01
Modeling the Internet's large-scale topology
UK PubMed Central (United Kingdom)
Network generators that capture the Internet's large-scale topology are crucial for the development of efficient routing protocols and modeling Internet traffic. Our ability to design realistic generators...Full Text Available
2002-10-15
Individually adapted examination protocols for reduction of radiation exposure in chest CT
International Nuclear Information System (INIS)
Feb 2002 p. 301 Germany Wildberger, JE Mahnken, AH Schmitz-Rode, T.
2002-02-01
Designing Exchange for Online Communities
In many online systems, individuals provide services for each other. Typically, the recipient of the service obtains a benefit while the provider of the service incurs a cost. Assuming that benefit exceeds cost, provision of the service increases social welfare and should therefore be encouraged -- but the individuals providing the service gain no (immediate) benefit from providing the service and hence have an incentive to withhold service. This paper studies the design of a system to encourage provision of service; the emphasis is on how the system designer should choose a protocol -- a supply of tokens and suggested strategies -- to maximize social welfare. In choosing this protocol, the system designer must take into account that agents are self-interested, and hence will comply with the protocol if and only if it is in their interests to do so. Moreover, we insist that the chosen protocol must be ...
2011-01-01
Communication and Round Efficient Information Checking Protocol
In this paper, we present a very important primitive called Information Checking Protocol (ICP) which plays an important role in constructing statistical Verifiable Secret Sharing (VSS) and Weak Secret Sharing (WSS) protocols. Informally, ICP is a tool for authenticating messages in the presence of computationally unbounded corrupted parties. Here we extend the basic bare-bone definition of ICP, introduced by Rabin et al. and then present an ICP that attains the best communication complexity and round complexity among all the existing ICPs in the literature. We also show that our ICP satisfies several interesting properties such as linearity property which is an important requirement in many applications of ICP. Though not presented in this paper, we can design communication and round efficient statistical (i.e involves negligible error probability in computation) VSS and Multiparty Computation (MPC) protocol using our new ...
2010-01-01
A quality based routing protocol for wireless mesh networks
British Library Electronic Table of Contents (United Kingdom)
Wireless mesh networks can provide low-cost solutions for extending the reach of wireless access points by using multi-hop routing over a set of stationary wireless routers. The routing protocol for these networks may need to address quality considerations to meet the requirements of the user. In this paper, we present a quality based routing protocol for wireless mesh networks that tries to maximize the probability of successful transmissions while minimizing the end-to-end delay. The proposed routing protocol uses reactive route discoveries to collect key parameters from candidate routes to estimate the probability of success and delay of data packets transmitted over them. To achieve accurate route quality assessments, a new route quality metric is proposed that uses performance models ...
2011-01-01
A practical microreactor for electrochemistry in flow
UK PubMed Central (United Kingdom)
SummaryA microreactor for electrochemical synthesis has been designed and fabricated. It has been shown that different reactions can be carried out successfully using simple protocols.
International Nuclear Information System (INIS)
For more than thirty years, the IAEA has published a set of documents aimed at the limitation of the radiation exposure of the population from various nuclear activities. In particular, in 1994 the IAEA published Technical Reports Series No. 364, Handbook of Parameter Values for the Prediction of Radionuclide Transfer in Temperate Environments. Over the years, it has proved to be a valuable reference for radioecologists, modellers and authorities in Member States, and has been quoted in numerous impact assessments. Technical Reports Series No. 364 was based on a review of available data up to the end of 1992. However, a number of high quality critical reviews have been produced in recent years for some of the transfer parameter values which merit consideration. Thus, it was assumed that there is sufficient new information available to warrant reconsideration of a significant proportion of the values given in Technical Reports Series No. 364 and ...
1993-04-05
Application of low-dose radiation protocols in survey CT scans
International Nuclear Information System (INIS)
Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized ...
2009-08-01
Training guidelines in non-destructive testing techniques. 2002 edition
International Nuclear Information System (INIS)
Non-destructive testing (NDT) is a dynamic technology and progresses with time. Since the issuance of IAEA-TECDOC-628 in 1991, the technology has experienced numerous changes. Advancements in knowledge about the behaviour of materials have led to changes in the applicable NDT codes, standards and specifications. In addition, over the last ten years, as a result of extensive research and development activities worldwide, new NDT techniques and equipment have been developed which are accepted by engineering community. To accommodate the latest developments, modifications are required to training materials. The present publication is an updated version of IAEA-TECDOC-628. The modifications were made during an Advisory Group Meeting, held in Vienna from 25-29 June 2001. The content of the first edition of IAEA-TECDOC-628 has been revised based on the experience of the experts, as well as comments of the end-user industries. The ...
1986-09-21
International Nuclear Information System (INIS)
The International Project on Innovative Nuclear Reactors and Fuel Cycles (INPRO) was launched in the year 2000, based on a resolution by the IAEA General Conference (GC(44)/RES/21). INPRO intends to help to ensure that nuclear energy is available in the 21st century in a sustainable manner, and seeks to bring together all interested Member States, both technology holders and technology users, to consider, jointly, actions to achieve desired innovations. INPRO is taking care of the specific needs of developing countries. This IAEA publication is part of Phase 1 of INPRO. It intends to provide an overview on history, present situation and future perspectives of nuclear fuel cycle technologies. While this overview focuses on technical issues, nevertheless, the aspects of economics, environment, and safety and proliferation resistance are important background issues for this study. After a brief description about the INPRO project and an evaluation ...
1991-01-01
Spent Fuel Transfer to Dry Storage Using Unattended Monitoring System
Energy Technology Data Exchange (ETDEWEB)
There are 4 CANDU reactors at Wolsung site together with a spent fuel dry storage associated with unit 1. These CANDU reactors, classified as On-Load Reactor (OLR) for Safeguards application, change 16- 24 fuel bundles with fresh fuel in everyday. Especially, the spent fuel bundles are transferred from spent fuel bays to dry storage throughout a year because of the insufficient capacity of spent fuel pond. Safeguards inspectors verify the spent fuel transfer to meet safeguards purposes according to the safeguards criteria by means of inspector's presence during the transfer campaign. For the verification, 60-80 person-days of inspection (PDIs) are needed during approximately 3 months for each unit. In order to reduce the inspection effort and operators' burden, an Unattended Monitoring System (UMS) was designed and developed by the IAEA for the verification of spent fuel bundles transfers from wet storage to dry storage. Based on the enhanced ...
2009-05-15
Monitoring processes and measuring the effectiveness of the management system
International Nuclear Information System (INIS)
This document presents the way which the 8th principle of the quality management system 'Process approach' is applied, the principle that is identified and used by international standard ISO 9000. In order to understand the evolution of the management system requirements, as used today in different activities namely, industry, services, and nuclear activities, the authors present an evolution of the quality concept and its traceability to different standards, applicable in time. There are described the requirements of ISO 9001 standard, that represents the most widely spread model for modern organization management and the IAEA concerns related to integration of the above standard requirements into the most recent safety IAEA standard 'The Management System for facilities and activities'. The IAEA Safety Standard GS-R-3 describes a management model considering both the evolution of the quality requirements into the modern ...
2009-10-12
New Protocol is 50th anniversary gift to CERN
"Nine of CERN 's 20 Member States today a signed new Protocol on privileges and immunities. This brings the Organization into line with other European intergovernmental organizations, such as the European Space Agency and the European Southern Observatory, which already enjoy international status in all of their Member States" (2
2004-01-01
Global post-Kyoto scenario analyses at PSI
Energy Technology Data Exchange (ETDEWEB)
Scenario analyses are described here using the Global MARKAL-Macro Trade (GMMT) model to study the economic implications of the Kyoto Protocol to the UN Convention on Climate change. Some conclusions are derived in terms of efficient implementations of the post-Kyoto extensions of the Protocol. (author) 2 figs., 5 refs.
1999-08-01
Field Test Protocol: Standard Internal Load Generation in Unoccupied Test Homes
Energy Technology Data Exchange (ETDEWEB)
This document describes a simple and general way to generate House Simulation Protocol (HSP)-consistent internal sensible and latent loads in unoccupied homes. It is newly updated based on recent experience, and provides instructions on how to calculate and set up the operational profiles in unoccupied homes. The document is split into two sections: how to calculate the internal load magnitude and schedule, and then what tools and methods should be used to generate those internal loads to achieve research goals.
2011-06-01
UK PubMed Central (United Kingdom)
PurposeRTOG protocol 95-17 was a phase I/II trial to evaluate multi-catheter brachytherapy as the sole method of adjuvant breast radiotherapy for stage I/II breast...Full Text Available
2007-12-01
Dispersant Effectiveness Of Heavy Fuel Oils Using The Baffled Flask Test
Dispersants have been widely used as a primary response measure for marine oil spills around the world. Recently, the U.S. Environmental Protection Agency (EPA) developed an improved laboratory dispersant testing protocol, called the Baffled Flask Test (BFT). The BFT protocol w...
The development of thyroid dose assessment software for nuclear or radiological emergency
International Nuclear Information System (INIS)
Objective: To develop software for assessment of dose to thyroid gland in emergencies resulting in the release of radioiodine. Methods: Based on procedures for thyroid monitoring and dose assessment introduced in IAEA publications (IAEA-TECDOC-1092 and EPR-MEDICAL-2005), a software was developed with Visual Basic 6.0 program to computerized the methods of thyroid dose estimation. Results: The intake of radioiodine and committed equivalent dose to thyroid could be estimated rapidly and accurately with the present software. Conclusion: The present software provide a practical and rapid tool for estimating thyroid doses received in emergencies resulting in the release of radioiodine by emergency workers and members of public, which is necessary for recommendation of further actions. (authors)
2006-12-01
International Nuclear Information System (INIS)
A Consultants' Meeting on 'The assessment of soil conservation technologies for sustainable agricultural production' was held in Vienna at the IAEA Headquarters from May 28-30, 2001. The consultants' presentations reviewed recent advances in the use of fallout radionuclides to measure soil erosion as well as approaches and technologies applied for soil conservation worldwide. Also, activities and experiences of FAO and UNEP in the field of land degradation, soil conservation and related issues were presented. Based on the information provided by the Scientific Secretary, a full project proposal was prepared during the second part of the Consultants' Meeting. The consultants also provided recommendations on the formulation and implementation of a future CRP on the subject.
2001-05-28
British Library Electronic Table of Contents (United Kingdom)
This paper is dedicated to the treatment of sludge occurring in frame of the Egyptian produced from oil and gas production. The activity levels of three radium isotopes: Ra-226 (of U-series), Ra-228 and Ra-224 (of Th-series) in the solid TENORM waste (sludge) were first evaluated and followed by a sequential treatment for all radium species (fractions) presented in TENORM. The sequential treatment was carried out based on two approaches `A' and `B' using different chemical solutions. The results obtained indicate that the activity levels of all radium isotopes (Ra-226, Ra-228 and Ra-224) of the environmental interest in the TENORM waste sludge were elevated with regard to exemption levels established by IAEA [International Atomic Energy Agency (IAEA), International basic safety standards f...
2009-01-01
International Nuclear Information System (INIS)
Joint FAO/IAEA/WHO Expert Committee approved the use of radiation treatment of foods. Nowadays food packaging are mostly made of plastics, natural or synthetic, therefore effect of irradiation on these materials is crucial for packing engineering for food irradiation technology. By selecting the right polymer materials for food packaging it can be ensured that the critical elements of material and product performance are not compromised. When packaging materials are in contact with food at the time of irradiation that regulatory approvals sometimes apply. The review of the R-and-D and technical papers regarding material selection, testing and approval is presented in the report. The most information come from the USA where this subject is well elaborated, the International Atomic Energy Agency (IAEA) reports are reviewed as well. The report can be useful for scientists and food irradiation plants operators. (author)
Introduction of Member State Support Program (MSSP) of Korea
International Nuclear Information System (INIS)
The demand of nuclear energy is sharply increasing to solve the energy and environment problems all over the world. The interest and support on the field of nuclear energy in Korea are enlarging as the acceptance of ordering nuclear power plant of UAE. The attention of safeguards is needed to maintain peaceful use of nuclear material and the nuclear nonproliferation as the increasing demand of nuclear energy. The International Atomic Energy Agency (IAEA) invests more in research and development to achieve the effective and efficient implementation of safeguards. Research and development (R and D) in safeguards approaches, procedures and techniques is essential to meeting the safeguards challenges of the future. The IAEA has conducted the R and D program through member state support program (MSSP) since 1977. The objective of this paper is to introduce the MSSP and policy of Korea on MSSP
2010-10-01
Grading of quality assurance requirements
International Nuclear Information System (INIS)
The present Manual provides guidance and illustrative examples for applying a method by which graded quality assurance requirements may be determined and adapted to the items and services of a nuclear power plant in conformance with the requirements of the IAEA Nuclear Safety Standards (NUSS) Code and Safety Guides on quality assurance. The Manual replaces the previous publication IAEA-TECDOC-303 on the same subject. Various methods of grading quality assurance are available in a number of Member States. During the development of the present Manual it was not considered practical to attempt to resolve the differences between those methods and it was preferred to identify and benefit from the good practices available in all the methods. The method presented in this Manual deals with the aspects of management, documentation, control, verification and administration which affect quality. 1 fig., 4 tabs.
Energy and nuclear power planning study for Thailand
International Nuclear Information System (INIS)
The present report describes the study conducted in co-operation with several agencies and organizations from Thailand and covers the energy and electricity requirements and the optimal expansion plans for the power generating system for this country up to year 2011. It is emphasized that the study was carried out by a team of experts from the Electricity Generating Authority of Thailand (EGAT), the National Economic and Social Development Board (NESDB), the National Energy Administration (NEA) and the Office of Atomic Energy for Peace (OAEP), who were fully responsible for all phases of the study, including the production of the present report. The IAEA's responsibility was to provide overall co-ordination and general guidance during the conduct of the study, as well as training and assistance in the implementation and use of the IAEA's computerized planning methodologies on the computer facilities of Thailand. Refs, figs and tabs.
2002-06-16
Packet Drop Avoidance for High-speed network transmission protocol
Energy Technology Data Exchange (ETDEWEB)
As network bandwidth continues to grow and longer paths are used to exchange large scientific data between storage systems and GRID computation, it has become increasingly obvious that there is a need to deploy a packet drop avoidance mechanism into network transmission protocols. Current end-to-end congestion avoidance mechanisms used in Transmission Control Protocol (TCP) have worked well on low bandwidth delay product networks, but with newer high-bandwidth delay networks they have shown to be inefficient and prone to unstable. This is largely due to increased network bandwidth coupled with changes in internet traffic patterns. These changes come from a variety of new network applications that are being developed to take advantage of the increased network bandwidth. This paper will examine the end-to-end congestion avoidance mechanism and perform a step-by-step analysis of its theory. In addition we will propose an alternative approach ...
2004-05-01
The result of Alanine/ESR dosimetry at Wolsung unit 1
International Nuclear Information System (INIS)
It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and ...
2008-10-01
ESR/Alanine dosimetry on Wolsung Unit 1
Energy Technology Data Exchange (ETDEWEB)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
2007-07-01
ESR/Alanine dosimetry on Wolsung Unit 1
International Nuclear Information System (INIS)
Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement result shows extremely high radiation level ...
2007-05-10
Energy Technology Data Exchange (ETDEWEB)
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)
1999-07-01
The computerized management for individual monitoring data in Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
The authors report the individual monitoring data management system (IDOSE) at Daya Bay Nuclear Power Station. The components of the individual monitoring system, the design requirements of IDOSE, the characteristics and application of this computerized management system are mainly presented. Its application shows that IDOSE meets the requirements of the concerning occupational standards of the state and matches with the requirements of IAEA/ISOE.
International Nuclear Information System (INIS)
The slow or stagnant rate of nuclear power generation development in many developed countries over the last two decades has resulted in a significant shortage in the population of mid-career nuclear industry professionals. This shortage is even more pronounced in some specific areas of expertise such as radiological protection, waste management and decommissioning. This situation has occurred at a time when the renaissance of nuclear power and the globalization of the nuclear industry are steadily gaining momentum and when the industry's involvement in international and national debates in these three fields of expertise (and the industry's impact on these debates) is of vital importance. This paper presents the World Nuclear Association (WNA) approach to building and enhancing worldwide industry cooperation in radiological protection, waste management and decommissioning, which is manifested through the activities of the two WNA working groups on radiological protection (RPWG) and on ...
International Nuclear Information System (INIS)
As the nuclear world is changing, the non-proliferation and safeguard systems have to change along the global development. Nuclear security as well as safety must be involved in all phases. Thus, modernization of thinking is a must. State system of accounting for and control of nuclear material (SSAC) is a basis, but now it is time to move ahead. Safeguards is not any more only to verify the declared nuclear materials but it is to inform the international safeguards society transparently but confidentially about the nuclear fuel cycle related activities and trade, and to confirm that there are no undeclared activities related to the nuclear fuel cycle in the states. Only strong SSAC with enhanced capabilities, activities and rights can meet the demand. The proliferation of nuclear weapons is a threat that also urges cooperation at all levels. International, regional and state systems must work closely together, and there is need and space for everyone. State systems must step forward ...
2010-11-01
Quality assurance requirements in various codes and standards
International Nuclear Information System (INIS)
The quality assurance requirements in various countries and according to various international codes and standards are presented, compared and critically discussed. Cases of developing countries are also discussed, and the use of IAEA code of practice and other codes for quality assurance in these countries is reviewed. Recommendations are made regarding the quality assurance system to be applied for Egypt's nuclear power plants.
IAEA advisory group meeting on basic and applied problems of nuclear level densities
International Nuclear Information System (INIS)
Separate entries were made in the data base for 17 of the 19 papers included. Two papers were previously included in the data base. Workshop reports are included on (1) nuclear level density theories and nuclear model reaction cross-section calculations and (2) extraction of nuclear level density information from experimental data.
1983-04-11
IAEA advisory group meeting on basic and applied problems of nuclear level densities
Energy Technology Data Exchange (ETDEWEB)
Separate entries were made in the data base for 17 of the 19 papers included. Two papers were previously included in the data base. Workshop reports are included on (1) nuclear level density theories and nuclear model reaction cross-section calculations and (2) extraction of nuclear level density information from experimental data. (WHK)
1983-06-01
IAEA Co-ordinated Research Program (CRP)
International Nuclear Information System (INIS)
The Coordinated Research Project is a topical collection of research agreements and contracts. The research contracts are awarded with financial support of about 10-20% of the total contract cost. Among the activities of the project is the organization of consultant group meetings and workshops involving several international experts and representatives of users and developers of border radiation monitoring equipment. The project also supports in coordinating the development of equipment and techniques for up-to-date border monitoring and in establishing of a process for providing nuclear forensics support to member states
2010-05-19
Thermoluminescent (Tl) dosimetry of slow-neutron fields at radiotherapy dose level
Energy Technology Data Exchange (ETDEWEB)
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced problems and various proposed solutions are here described. (Author)
2003-07-01
Energy Technology Data Exchange (ETDEWEB)
It was developed a new formulation of macro aggregates of Samarium 153 ({sup 153} Sm-MH) for the arthropaties treatment. The radio pharmaceutic was prepared by reaction of Samarium 153 chloride (SmCl{sub 3}) in aqueous environment with sodium boron hydride in NaOH 0.5 N. The microscopic analysis shown that the particles have an average size of 4% m (range 1-14 {mu} m). The velocity of sedimentation was 0.008 cm/min with high stability in vitro in human serum. The biological studies in healthy rabbits, shown that the complex is retained inside the articulation still eight days after of the administration of the radiopharmaceutical. Likewise, it is presented the data of absorbed dose in the different target organs, which was determined by thermoluminescent dosimetry (TLD) through the use of a REMCAL phantom (radiation equivalent manikin calibration). (Author)
1999-07-01
On-line dosimetry for BNCT at the MIT research reactor
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.
1996-12-31
On-line dosimetry for BNCT at the MIT research reactor
International Nuclear Information System (INIS)
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate measures taken.
1996-11-10
Energy Technology Data Exchange (ETDEWEB)
The technical complexity of intraoperative radiotherapy (IORT) requires modification of the standard physical and dosimetric methods used in external electron beam therapy. At the National Cancer Institute, a number of technical innovations have been integrated into ongoing clinical studies of IORT. These include: (1) an electron beam applicator system that is significantly different from other IORT systems and includes customized squircle applicators; (2) peripheral dose shields; (3) a modified surgical table replacing the standard radiation treatment couch; and (4) routine use of multiple IORT fields that necessitates field matching. The IORT applicator system and related devices and techniques are dosimetrically characterized in detail both for use in the IORT program and in order to illustrate many useful facets of electron dosimetry.
1985-07-01
International Nuclear Information System (INIS)
This document is the report of a task group of the Radiation Therapy Committee of the AAPM and has been prepared primarily to advise hospital physicists involved in external beam treatment of patients with pelvic malignancies who have high atomic number (Z) hip prostheses. The purpose of the report is to make the radiation oncology community aware of the problems arising from the presence of these devices in the radiation beam, to quantify the dose perturbations they cause, and, finally, to provide recommendations for treatment planning and delivery. Some of the data and recommendations are also applicable to patients having implanted high-Z prosthetic devices such as pins, humeral head replacements. The scientific understanding and methodology of clinical dosimetry for these situations is still incomplete. This report is intended to reflect the current state of scientific understanding and technical methodology in clinical dosimetry for ...
2003-06-01
Dose dependence of semiconductor material conductivity as a means of high fluence dosimetry
Energy Technology Data Exchange (ETDEWEB)
Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).
1996-12-31
A TLD powder dosimetry measurement system for physical models of reference man
International Nuclear Information System (INIS)
A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)
1978-12-01
StoRHm: a protocol adapter for mapping SOAP based Web Services to RESTful HTTP format
British Library Electronic Table of Contents (United Kingdom)
A protocol adapter ideally suited to enable enterprises to gradually transition from SOAP Web Services to RESTful HTTP Web Services without impacting existing clients is presented in this paper. The inherent advantage of such a transition is the visibility of RESTful HTTP messages to Web intermediaries such as caches. In contrast, SOAP messages are opaque, which disables Web intermediaries. While both approaches can use HyperText Transfer Protocol (HTTP) for message transfer, the paradigms contrast sharply. SOAP uses an interface specific approach whereas RESTful HTTP uses a Uniform Interface approach. SOAP marks up its payload with eXtensible Markup Language (XML) whereas in certain situations RESTful HTTP requires no XML. We present the disadvantages of the SOAP approach and outline how ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Current Intrusion Detection System (IDS) technology is not suited to be widely deployed inside a Supervisory, Control and Data Acquisition (SCADA) environment. Anomaly- and signature-based IDS technologies have developed methods to cover information technology-based networks activity and protocols effectively. However, these IDS technologies do not include the fine protocol granularity required to ensure network security inside an environment with weak protocols lacking authentication and encryption. By implementing a more specific and more intelligent packet inspection mechanism, tailored traffic flow analysis, and unique packet tampering detection, IDS technology developed specifically for SCADA environments can be deployed with confidence in detecting malicious activity.
2008-05-01
British Library Electronic Table of Contents (United Kingdom)
The Kyoto Protocol attempts through political negotiations to guide participating industrialized countries' greenhouse gas (GHG) emissions from a positive growing trend, to reach a peak point (or turning point), and then be reduced to a negative growth. That means the relationship between decreasing GHG emissions and economic growth may be described by an inverted-U curve (or called a bell-shaped curve), which is consistent with the concept of the Environmental Kuznets Curve (EKC) hypothesis.This research observed that the economic development and GHG emissions in Economies in Transition (EITs) exhibit a hockey-stick curve trend (or called quasi-L-shape curve), that also generates a lot of "hot air" which is significant to the implementation of the Kyoto Protocol. In addition, through the ...
2008-01-01
Communication Estimation for Hardware/Software Codesign
DEFF Research Database (Denmark)
This paper presents a general high level estimation model of communication throughput for the implementation of a given communication protocol. The model, which is part of a larger model that includes component price, software driver object code size and hardware driver area, is intended to be general enough to be able to capture the characteristics of a wide range of communication protocols and yet to be sufficiently detailed as to allow the designer or design tool to efficiently explore tradeoffs between throughput, bus widths, burst/non-burst transfers and data packing strategies. Thus it provides a basis for decision making with respect to communication protocols/components and communication driver design in the initial design space exploration phase of a co-synthesis process where a large number of possibilities must be examined and where fast estimators are therefore necessary. The fill model allows for additional ...
1998-01-01
A MAC protocol for cognitive wireless sensor body area networking
British Library Electronic Table of Contents (United Kingdom)
Abstract In this paper, a Cognitive Radio Based Medium Access Control (CR-MAC) protocol for Wireless Sensor Body Area Networks (WSBAN) that utilizes cognitive radio transmission is proposed. In this proposal, the sensor nodes are classified into nodes of life-critical health information and nodes of non-critical health information. The CR-MAC protocol prioritizes the critical packets access to the transmission medium by transmitting them with higher power while transmitting lower priority packets using lower transmission power. At the receiver, a higher priority packet experiences collision only when there are more than one critical packet transmission at the same transmission slot while non critical packets experience collision when there are more than one transmission at the same transmi...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Because of past military operations, lack of upkeep and looting there are now enormous radioactive waste problems in Iraq. These waste problems include destroyed nuclear facilities, uncharacterized radioactive wastes, liquid radioactive waste in underground tanks, wastes related to the production of yellow cake, sealed radioactive sources, activated metals and contaminated metals that must be constantly guarded. Iraq currently lacks the trained personnel, regulatory and physical infrastructure to safely and securely manage these facilities and wastes. In 2005 the International Atomic Energy Agency (IAEA) agreed to organize an international cooperative program to assist Iraq with these issues. Soon after, the Iraq Nuclear Facility Dismantlement and Disposal Program (the NDs Program) was initiated by the U.S. Department of State (DOS) to support the IAEA and assist the Government of Iraq (GOI) in eliminating the threats from poorly controlled ...
2009-03-01
Zoledronate to Preserve Bone Mineral Density
Phase II Randomized Study of the Effect of Zoledronate Versus Observation on Bone Mineral Density of the Lumbar Spine in Patients Undergoing Risk-Reducing Excision of Both Ovaries (GOG-0215). See the protocol summary.
The translation research in a dental setting (TRiaDS) programme protocol
UK PubMed Central (United Kingdom)
BackgroundIt is well documented that the translation of knowledge into clinical practice is a slow and haphazard process. This is no less true for dental healthcare than other types...Full Text Available
Surprising Alteration of Antibacterial Activity of 5?-Modified Neomycin against Resistant Bacteria
UK PubMed Central (United Kingdom)
A facile synthetic protocol for the production of neomycin B derivatives with various modifications at the 5″ position has been developed. Structural activity relationship (SAR) against...Full Text Available
2008-12-11
UK PubMed Central (United Kingdom)
BackgroundThere have been dramatic changes in the approach to screening for aneuploidy over the last 20 years. However, the approach to screening for other complications of pregnancy...Full Text Available
Simple Behavioral Assessment of Mouse Olfaction
UK PubMed Central (United Kingdom)
This unit presents two basic protocols that offer rapid assessments of anosmia (the absence of a sense of smell) in mice. The buried food test is used to check for the ability to smell volatile...Full Text Available
2009-07-01
Return of Postural Control to Baseline After Anaerobic and Aerobic Exercise Protocols
UK PubMed Central (United Kingdom)
Context:With regard to sideline concussion testing, the effect of fatigue associated with different types of exercise on postural control is unknown.Objective:To...Full Text Available
2008-09-01
UK PubMed Central (United Kingdom)
The relative sensitivities of different protocols for detecting cytomegalovirus nucleic acid sequences in histological specimens, using a biotinylated cDNA probe, were assessed. Several commonly used...Full Text Available
1987-08-01
UK PubMed Central (United Kingdom)
BackgroundAcute lower respiratory infections are the commonest cause of morbidity and potentially preventable mortality in Indigenous infants. Infancy is also a critical time for...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundThe aim of this double-blind randomized study is to test the efficacy of a radio electric stimulator device using an auricular reflex therapy protocol for stress-related...Full Text Available
Energy Technology Data Exchange (ETDEWEB)
The Executive Body adopted the Protocol on Heavy Metals on 24 June 1998 in Aarhus (Denmark). It targets three particularly harmful metals: cadmium, lead and mercury. According to one of the basic obligations, parties will have to reduce their emissions for these three metals below their levels in 1990. The Protocol aims to cut emissions from industrial sources, combustion process and waste incineration. It lays down strighten limit values for emissions from stationary sources and suggests best available techniques (BAT) for these sources, such as special filters or scrubbers for combustion sources or mercury-free processes. The Protocol requires parties to phase out leaded petrol. It also introduces measures to lower heavy metal emissions from other products, such as mercury in batteries, and proposes the introduciton of management measures for other mercury-containing products, such as electrical componets (thermostats, ...
2003-08-01
Protocol for the Proactive Or Reactive Telephone Smoking CeSsation Support (PORTSSS) trial
UK PubMed Central (United Kingdom)
BackgroundTelephone quit lines are accessible to many smokers and are used to engage motivated smokers to make quit attempts. Smoking cessation counselling provided via telephone...Full Text Available
Pitfalls with the "chest compression-only" approach: the challenge of an unusual cause
UK PubMed Central (United Kingdom)
Chest compression-only (CC-only) is now incorporated in the Norwegian protocol for dispatch guided CPR (cardiopulmonary resuscitation) in cardiac arrest of presumed cardiac aetiology.We present...Full Text Available
Occupational health priorities for health standards: the current NIOSH approach.
UK PubMed Central (United Kingdom)
Government agencies responsible for protecting the public from the adverse effects of toxic chemicals must set priorities for research, regulatory action, protocol testing, and monitoring due to the...Full Text Available
1979-05-01
UK PubMed Central (United Kingdom)
BackgroundWe have recently reported successful treatment of patients with chronic pain syndromes using human pooled intravenous immunoglobulin (IVIG) in a prospective, open-label...Full Text Available
UK PubMed Central (United Kingdom)
Understanding the dynamics of porcine reproductive and respiratory syndrome virus (PRRSV) vertical transmission is important to enhance the accuracy of monitoring protocols for endemically infected...Full Text Available
2009-10-01
Heterogeneity of engrafted bone-lining cells after systemic and local transplantation
UK PubMed Central (United Kingdom)
The outcome of various osteoprogenitor-cell transplantation protocols was assessed using Col1a1-GFP reporter transgenic mice. The model requires the recipient mice to undergo lethal total body irradiation...Full Text Available
2005-11-15
UK PubMed Central (United Kingdom)
BackgroundEpidemiological studies showed that physical exercise, specifically moderate lifelong training, is protective against cardiovascular morbidity and mortality. Most experimental...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundIn patients with Stage 5 Chronic Kidney Disease who require renal replacement therapy a major decision concerns modality choice. However, many patients defer the decision...Full Text Available
Estimating and managing uncertainties in order to detect terrestrial greenhouse gas removals
Energy Technology Data Exchange (ETDEWEB)
Inventories of emissions and removals of greenhouse gases will be used under the United Nations Framework Convention on Climate Change and the Kyoto Protocol to demonstrate compliance with obligations. During the negotiation process of the Kyoto Protocol it has been a concern that uptake of carbon in forest sinks can be difficult to verify. The reason for large uncertainties are high temporal and spatial variability and lack of representative estimation parameters. Additional uncertainties will be a consequence of definitions made in the Kyoto Protocol reporting. In the Nordic countries the national forest inventories will be very useful to estimate changes in carbon stocks. The main uncertainty lies in the conversion from changes in tradable timber to changes in total carbon biomass. The uncertainties in the emissions of the non-CO{sub 2} carbon from forest soils are particularly high. On the other hand the removals ...
2002-07-01
Entanglement-secured single-qubit quantum secret-sharing
In single-qubit quantum secret sharing, a secret is shared between N parties via manipulation and measurement of one qubit at a time. Each qubit is sent to all N parties in sequence; the secret is encoded in the first participant's preparation of the qubit state and the subsequent participants' choices of state rotation or measurement basis. We present a protocol for single-qubit quantum secret sharing using polarization entanglement of photon pairs produced in type-I spontaneous parametric downconversion. We investigate the protocol's security against eavesdropping attack under common experimental conditions: a lossy channel for photon transmission, and imperfect preparation of the initial qubit state. A protocol which exploits entanglement between photons, rather than simply polarization correlation, is more robustly secure. We implement the entanglement-based secret-sharing protocol with 87% ...
2011-01-01
UK PubMed Central (United Kingdom)
BackgroundChronic rotator cuff pathology (CRCP) is a common shoulder condition causing pain and disability. Physiotherapy is often the first line of management for CRCP yet there...Full Text Available
...Goods: promote the protection of ldquo;natural parks and reserves, mangroves, reefs and lagoons,rdquo; and ldquo;expanding forest cover and tree integration with agricultural production systems rdquo;; climate change will be reduced through the trading of pollution permits under the Kyoto Protocol. Enhancing Disaster Management Capabilities:...
UK PubMed Central (United Kingdom)
BackgroundWith the phasing out of ozone-depleting substances in accordance with the United Nations Montreal Protocol, phosphine remains as the only economically viable fumigant for...Full Text Available
UK PubMed Central (United Kingdom)
Teleost gut associated lymphoid tissue (GALT) consists of leucocyte populations located both intraepithelially and in the lamina propria with no structural organization. The present study aims to assess...Full Text Available
UK PubMed Central (United Kingdom)
BackgroundThe composition of habitual diets is associated with adverse or protective effects on aspects of health. Consequently, UK public health policy strongly advocates dietary...Full Text Available
Adhesive capsulitis and dynamic splinting: a controlled, cohort study
UK PubMed Central (United Kingdom)
BackgroundAdhesive Capsulitis (AC) affects patient of all ages, and stretching protocols are commonly prescribed for this condition. Dynamic splinting has been shown effective in...Full Text Available
A protocol for the production of recombinant spider silk-like proteins for artificial fiber spinning
UK PubMed Central (United Kingdom)
The extreme strength and elasticity of spider silks originate from the modular nature of their repetitive proteins. To exploit such materials and mimic spider silks, comprehensive strategies...Full Text Available
2009-01-01
A Disordered Eating Response Team's Effect on Nutrition Practices in College Athletes
UK PubMed Central (United Kingdom)
The disordered eating response team developed a protocol for assessment and intervention for athletes who are identified as at risk for disordered eating. Team members included the team physician,...Full Text Available
1995-10-01
Two Avowable Quantum Communication Schemes
International Nuclear Information System (INIS)
Two avowable quantum communication schemes are proposed. One is an avowable teleportation protocol based on the quantum cryptography. In this protocol one teleports a set of one-particle states based on the availability of an honest arbitrator, the keys and the Einstein-Podolsky-Rosen pairs shared by the communication parties and the arbitrator. The key point is that the fact of the teleportation can neither be disavowed by the sender nor be denied by the receiver. Another is an avowable quantum secure direct communication scheme. A one-way Hash function chosen by the communication parties helps the receiver to validate the truth of the information and to avoid disavowing for the sender.
2008-11-15
Two Avowable Quantum Communication Schemes
Two avowable quantum communication schemes are proposed. One is an avowable teleportation protocol based on the quantum cryptography. In this protocol one teleports a set of one-particle states based on the availability of an honest arbitrator, the keys and the Einstein Podolsky Rosen pairs shared by the communication parties and the arbitrator. The key point is that the fact of the teleportation can neither be disavowed by the sender nor be denied by the receiver. Another is an avowable quantum secure direct communication scheme. A one-way Hash function chosen by the communication parties helps the receiver to validate the truth of the information and to avoid disavowing for the sender.
2008-11-01
Radiation doses and somatic risk to patients during cardiac radiological procedures
International Nuclear Information System (INIS)
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
1986-01-01
Radiation Dosimetry considerations in the safe administration of therapeutic radiopharmaceuticals
Energy Technology Data Exchange (ETDEWEB)
A set of eight questions was put to advanced nuclear medicine physicians-in-training participating in a continuing assessment exercise in practical therapeutic nuclear oncology. Using the particular example of {sup 131}I-MIBG treatment of neuroblastoma in children, the questions were directed to the rationale of therapy and the contribution of other forms of treatment to toxic effects. The best answer to the questions are reproduced together with an introduction by the examiner, Dr. H. Turner. tabs.
1995-12-01
Optical Fiber Sensors from Laboratory to Field Trials: Applications and Trends at CEA LIST
British Library Electronic Table of Contents (United Kingdom)
Fiber optic metrology developed at the CEA LIST laboratories involves fiber Bragg grating sensors, distributed Brillouin optical time domain reflectometry and optically stimulated luminescence dosimetry. Recent activities in optical fiber sensing are reviewed from laboratory experiments to field trials.
2009-01-01
International Nuclear Information System (INIS)
Thermoluminescence (TL) and Electron Paramagnetic Resonance (EPR) dosimetry were used to measure dose effects in borosilicate glass with time, from 10 minutes to #approx#60 days following exposure to a dose of up to 10,000 Rad. TL and EPR results were consistent and performed similarly, with both techniques capable of achieving an estimated limit of detection of between 50-100 Rad. Three peaks were identified in the TL glow curve at roughly 110 C, 205 C, and 225 C. The intensity of the 205 C peak was the dominant peak over the time period of this study. The stability of all of the peaks with time since irradiation increased with their corresponding temperature and little or no variation was observed in the glow curve response to a specified total dose attained at different dose rates. The intensity of the 205 C peak decreased logarithmically with time regardless of total dose. Based upon a conservative limit of detection of 330 Rad, a 10,000 Rad dose would still be ...
Influencing factors on ESR dose assessment in irradiated chicken legs
Energy Technology Data Exchange (ETDEWEB)
Electron spin resonance (ESR) dosimetry of irradiated chicken legs is based on the additive dose or the calibration curve methods. In both cases the practical assumption is made that the behaviour of the chicken bone does not depend on factors such as temperature during irradiation, storage conditions and dose rate. So the aim of the present work was to investigate to what extent the above mentioned factors could influence the post-irradiation dose assessment using the ESR technique. (author).
1996-12-31
INEEL Advanced Radiotherapy Research Program Annual Report for 2002
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.
2003-05-01
INEEL Advanced Radiotherapy Research Program Annual Report 2002
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the activities and major accomplishments for the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2002. Topics covered include computational dosimetry and treatment planning software development, medical neutron source development and characterization, and boron analytical chemistry.
2003-05-23
FY 1999 Laboratory Directed Research and Development annual report
Energy Technology Data Exchange (ETDEWEB)
A short synopsis of each project is given covering the following main areas of research and development: Atmospheric sciences; Biotechnology; Chemical and instrumentation analysis; Computer and information science; Design and manufacture engineering; Ecological science; Electronics and sensors; Experimental technology; Health protection and dosimetry; Hydrologic and geologic science; Marine sciences; Materials science; Nuclear science and engineering; Process science and engineering; Sociotechnical systems analysis; Statistics and applied mathematics; and Thermal and energy systems.
2000-06-13
Electron linear accelerators for radiotherapy
International Nuclear Information System (INIS)
Present-day requirements for radiotherapy equipment are considered. The recently developed linacs of LUE-5, LUE-25, LUE-15MM models, as well as a newly designed unified series of medical linacs of LUER-5M, LUER-20M, LUER-40M models are described in brief. The main scientific and technical problems that were solved during their construction, namely, development of accelerating structures, a radiation head, dosimetry equipment, a programming unit, a magnetic mirror etc. are described.
1983-06-01
Dosimetry in dental radiology. Dentascan spiral CT versus panoramic radiography
International Nuclear Information System (INIS)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations.
1999-05-01
Development and evaluation for passive dosimeter using several solid dosimeters
International Nuclear Information System (INIS)
Passive dosimeters for personal and area radiation monitor in space have been developed mainly for dosimetry in low-earth-orbit (LEO) radiation environments of Space Shuttles and the International Space Station. The responses of several dosimeters have been evaluated by heavy ions and also its variation for individual dosimeter element. (author)
2005-05-01
UK PubMed Central (United Kingdom)
The aim of this study is to compare the dosimetry results that are obtained by using Convolution, Superposition and Fast Superposition algorithms in Conventional Radiotherapy, Three-Dimensional Conformal...Full Text Available
2009-01-01
Clinical helical tomotherapy commissioning dosimetry
International Nuclear Information System (INIS)
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.
2003-12-01
Automated remote positioning and examination of FFTF reactor power characterization dosimeters
Energy Technology Data Exchange (ETDEWEB)
The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.
1981-05-04
Applications of Bonner sphere detectors in neutron field dosimetry
Energy Technology Data Exchange (ETDEWEB)
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
1983-09-01
6. Workshop on heavy-charged particles in biology and medicine. Book of abstracts
Energy Technology Data Exchange (ETDEWEB)
Topics of this proceedings are: DNA damage and repair; Space research; Cell and tissue radiobiology; Treatment planning 1: The role of clinical RBEs; Treatment planning 2: Dose optimization and inverse planning; Dosimetry; Clinical results of particle therapy and new techniques; Status reports and future developments. Separate abstracts were prepared for 79 chapters. (orig./SR)
1997-09-01
International Nuclear Information System (INIS)
The purpose of this study is to develop a geometrically accurate imaging protocol at 3 T magnetic resonance imaging (MRI) for stereotactic radiosurgery (SRS) treatment planning. In order to achieve this purpose, a methodology is developed to investigate the geometric accuracy and stability of 3 T MRI for SRS in phantom and patient evaluations. Forty patients were enrolled on a prospective clinical trial. After frame placement prior to SRS, each patient underwent 3 T MRI after 1.5 T MRI and CT. MR imaging protocols included a T1-weighted gradient echo sequence and a T2-weighted spin echo sequence. Phantom imaging was performed on 3 T prior to patient imaging using the same set-up and imaging protocols. Geometric accuracy in patients and phantoms yielded comparable results for external fiducial reference deviations and internal landmarks between 3 T and 1.5 T MRI (mean ?0.6 mm; standard deviation ?0.3 mm). Mean stereotactic ...
2010-11-21
International Nuclear Information System (INIS)
The paper presents the progress of the Radioactive Waste Management Plan which accompanies the Decommissioning Plan for research reactor WWR-S located in Magurele, Ilfov, near Bucharest, Romania. The new variant of the Decommissioning Plan was elaborated taking into account the IAEA recommendation concerning radioactive waste management. A new feasibility study for WWR-S decommissioning was also developed. The preferred safe management strategy for radioactive wastes produced by reactor decommissioning is outlined. The strategy must account for reactor decommissioning, as well as rehabilitation of the existing Radioactive Waste Treatment Plant and the upgrade of the Radioactive Waste Disposal Facility at Baita-Bihor. Furthermore, the final rehabilitation of the laboratories and reusing of cleaned reactor building is envisaged. An inventory of each type of radioactive waste is presented. The proposed waste management strategy is selected in accordance with the ...
2008-05-28
Status of non-electric nuclear heat applications: Technology and safety
International Nuclear Information System (INIS)
Nuclear energy plays an important role in electricity generation, producing 16% of the world's electricity at the beginning of 1999. It has proven to be safe, reliable, economical and has only a minimal impact on the environment. Most of the world's energy consumption, however, is in the form of heat. The market potential for nuclear heat was recognized early. Some of the first reactors were used for heat supply, e.g. Calder Hall (United Kingdom), Obninsk (Russian Federation), and Agesta (Sweden). Now, over 60 reactors are supplying heat for district heating, industrial processes and seawater desalination. But the nuclear option could be better deployed if it would provide a larger share of the heat market. In particular, seawater desalination using nuclear heat is of increasing interest to some IAEA Member States. In consideration of the growing experience being accumulated, the IAEA periodically reviews the progress and new developments in ...
Coordinated Research Project (CRP) was initiated in 2002 by IAEA to enable Member States in developing methodologies for reducing radio-toxic discharge to the environment from nuclear fuel cycle activities and in paving the way for sustainability of nuclear energy. In the past three Research Coordination Meetings (RCM), the following areas of research were examined upon: (1)Basic studies to compare dry partitioning process with aqueous partitioning process; (2)Defining proliferation resistance attributes of partitioning processes; (3) Advanced characterization methods for actinides for measuring the possible material holdup;( 4)Minimization of actinides losses in the waste fraction from the partitioning process;(5)Establishment of separation criteria of partitioning process to minimize environmental impact; and (6)Defining environmental impact associated with partitioning processes. The final TECDOC is currently being prepared to summarize the activities of this ...
2007-07-01
Pollution in the Gulf: Monitoring the marine environment
International Nuclear Information System (INIS)
More than 2 years after the Gulf conflict, scientists are continuing to keep a close watch on marine pollution stemming from the war. Following the conflict in early 1991, major concern was raised worldwide when an estimated four to eight million barrels of crude oil were directly released into the Persian Gulf from the Sea Island terminal in Kuwait. Such amounts clearly made it the largest oil spill in history. The catastrophe was exacerbated when Kuwaiti oil fields were ignited. The magnitude of the pollution, and the types of toxic contaminants involved, led to a worldwide response through the United Nations system. An inter-agency plan of action was developed quickly. As one of its steps, the co-ordinating agency - the United Nations Environment Programme (UNEP) - asked the IAEA's Marine Environment Laboratory (MEL) in Monaco to help make a preliminary assessment of the situation. The Laboratory's main goal in initial surveys was to map the extent and general ...
Energy Technology Data Exchange (ETDEWEB)
The International Atomic Energy Agency (IAEA) started the Coordinated Research Program entitled ```The Safety Assessment of Near-Surface Radioactive Waste Disposal Facilities.`` The program is aimed at improving the confidence in the modeling results for safety assessments of waste disposal facilities. The program has been given the acronym NSARS (Near-Surface Radioactive Waste Disposal Safety Assessment Reliability Study) for ease of reference. The purpose of this report is to present the ORNL modeling results for the first test case (i.e., Test Case 1) of the IAEA NSARS program. Test Case 1 is based on near-surface disposal of radionuclides that are subsequently leached to a saturated-sand aquifer. Exposure to radionuclides results from use of a well screened in the aquifer and from intrusion into the repository. Two repository concepts were defined in Test Case 1: a simple earth trench and an engineered vault.
1993-07-01
Elemental investigation of Syrian medicinal plants using PIXE analysis
Energy Technology Data Exchange (ETDEWEB)
Particle induced X-ray emission (PIXE) technique has been employed to perform elemental analysis of K, Ca, Mn, Fe, Cu, Zn, Br and Sr for Syrian medicinal plants used traditionally to enhance the body immunity. Plant samples were prepared in a simple dried base. The results were verified by comparing with those obtained from both IAEA-359 and IAEA-V10 reference materials. Relative standard deviations are mostly within {+-}5-10% suggest good precision. A correlation between the elemental content in each medicinal plant with its traditional remedial usage has been proposed. Both K and Ca are found to be the major elements in the samples. Fe, Mn and Zn have been detected in good levels in most of these plants clarifying their possible contribution to keep the body immune system in good condition. The contribution of the elements in these plants to the dietary recommended intakes (DRI) has been evaluated. Advantages and limitations of PIXE ...
2010-09-15
Challenges in validating the sterilisation dose for processed human amniotic membranes
Energy Technology Data Exchange (ETDEWEB)
Most of the tissue banks in the Asia Pacific region have been using ionising radiation at 25 kGy to sterilise human tissues for save clinical usage. Under tissue banking quality system, any dose employed for sterilisation has to be validated and the validation exercise has to be a part of quality document. Tissue grafts, unlike medical items, are not produced in large number per each processing batch and tissues relatively have a different microbial population. A Code of Practice established by the International Atomic Energy Agency (IAEA) in 2004 offers several validation methods using smaller number of samples compared to ISO 11137 (1995), which is meant for medical products. The methods emphasise on bioburden determination, followed by sterility test on samples after they were exposed to verification dose for attaining of sterility assurance level (SAL) of 10{sup -1}. This paper describes our experience in using the IAEA Code of Practice in ...
2007-11-15
Break Nodalization Influence to IAEA-SPE-4 Test Simulation
International Nuclear Information System (INIS)
A small break LOCA event simulation with no high pressure injection system available, known as International Atomic Energy Agency Standard Problem Exercise no. 4 (IAEA-SPE-4), was performed on the PMK-2 integral test facility in Budapest in 1993. This paper analyses the response of the PMK-2 facility, a model of VVER-440 nuclear power plant, using the latest released version MOD3.2.1.2 of the RELAP5 thermal-hydraulic code. After several years of the SPE-4 experiment analyses, many problems have emerged and been studied. Main goal of the present analyses was to study the main influencing parameters for adequate modelling of the hexagonal core channel with 19-rod bundle and phenomena during the core uncovery. Some influencing parameters have been identified, mostly on the primary side, but some also on the secondary side. This is exact simulation of main coolant pump coast down, hydro-accumulators water temperature and connections to the primary system. Some concern ...
1998-06-15
Use of stable isotopes in developing countries: safe markers for nutrition regime study
International Nuclear Information System (INIS)
Possible use of stable radioisotopes in studies on nutrition and medicine problems that may be used in investigations of babies, children, pregnant women is shown. Attention is paid to behaviour of limited number of elements: hydrogen, carbon, nitrogen, oxygen. The IAEA plans implementation of a new coordinated research program on use of stable isotopes for studying nutrition problems and related diseases. The program emphasis will be placed on protein metabolism measurements and estimation of energy consumption in control population groups in developing countries.
Self-consistent electric field effect on electron transport of ECH plasmas
Energy Technology Data Exchange (ETDEWEB)
An algorithm is proposed which treats the ECH generated potential in a self-consistent way, by extending the Monte-Carlo Fokker-Planck method used by Murakami [S. Murakami et al., Proc. 17th IAEA Fusion Energy Conference, Yokohama, 1998 (International Atomic Energy Agency, Vienna, in press), paper CN-69/TH2/1]. The additional physics is expected to influence the transport of both thermal and suprathermal electrons in a helical toroidal system. (author)
1999-02-01
International Nuclear Information System (INIS)
The exchange of information and experience among Member Sates is an essential component of the IAEA action plan for addressing the Year 2000 problem. The objective is to enable Member States to identify any gaps in their own conversion programmes, benefit form the experience of others in developing remedial actions and establish the basis for future action to solve remaining problems. Experts in Year 2000 issues particularly those related to digital equipment prepared this report dealing with nuclear fuel cycle facilities
1993-04-18
IAEA Coordinated Research Project: Updated decay data library for actinides
Energy Technology Data Exchange (ETDEWEB)
Recommended nuclear decay data for specific actinides are important in fuel-cycle studies for thermal and fast reactors and inventory studies for safeguards. Therefore, a programme of work was initiated in 2005 to improve the actinide decay data library of the International Atomic Energy Agency through the efforts of a Coordinated Research Project (CRP). The proposed contents of the new database are described, including the agreement to include additional actinides and a significant number of natural decay chain radionuclides. This work is on-going, and is estimated for completion in 2009/10.
2008-06-15
International Nuclear Information System (INIS)
A database has been compiled on human dietary intakes of trace elements by populations groups living in various countries. The main sources of information used were (1) publications in the open scientific literature, and (2) data submitted to the IAEA in response to a questionnaire. The database contains 1,758 intake values covering 35 elements and 47 countries. In this report the data are listed in various ways to facilitate identification of intake values for any specified country, element and population group. 4 refs, 5 tabs.
A study to develop the domestic functional requirements of the specific safety systems of CANDU
Energy Technology Data Exchange (ETDEWEB)
The present research has been made to develop and review critically the functional requirements of the specific safety systems of CANDU such as SDS-1, SDS2, ECCS, and containment. Based on R documents for this, a systematic study was made to develop the domestic regulation statements. Also, the conventional laws are carefully reviewed to see the compatibility to CANDU. Also, the safety assessment method for CANDU was studied by reviewing C documents and recommendation of IAEA. Through the present works, the vague policy in the CANDU safety regulation is cleaning up in a systematic form and a new frame to measure the objective risk of nuclear power plants was developed.
2003-03-15
A study to develop the domestic functional requirements of the specific safety systems of CANDU
Energy Technology Data Exchange (ETDEWEB)
The present research has been made to develop and review critically the functional requirements of the specific safety systems of CANDU such as SOS-1, SOS-2, ECCS and containment. Based on R documents for this, a systematic study was made to develop the domestic regulation statements. Also, the conventional laws are carefully reviewed to see the compatibility to CANDU. Also, the safety assessment method for CANDU was studied by reviewing C documents and recommendation of IAEA. Through the present works, the vague policy in the CANDU safety regulation is cleaning up in a systematic form and a new frame to measure the objective risk of nuclear power plants was developed.
2001-03-15
A study for good regulation of the CANDU's in Korea
Energy Technology Data Exchange (ETDEWEB)
The objective of project is to derive the policy recommendations to improve the efficiency of CANDU plants regulation. These policy recommendations will eventually contribute to the upgrading of Korean nuclear regulatory system and safety enhancement. During the second phase of this 2 years study, following research activities were done. Review the technical basis and framework of the new Canadian Regulation System and IAEA. Analysis on the interview of Wolsung operation staffs to identify important safety issues and regulation problems experienced at operation. Providing a plan of CANDU regulation system enhancement program.
2002-03-15
6. Sample preparation for determining pollutants in components of the environment
International Nuclear Information System (INIS)
Examples are given of reference materials for radionuclide X-ray fluorescence analysis (RXFA) of the environment processed by the National Bureau of Standards and the IAEA. Methods are described used for preparing standard materials for RXFA. For determining air pollutants the sample is prepared by dry or wet mineralization. Water samples have to be preserved prior to analysis. Insoluble components are separated by filtration or centrifugation. Biological materials must be dehydrated and homogenized. Samples of soil, sludges, sediments and solid wastes will sometimes have to be converted into a solution in some cases a leachate will have to be obtained. (ES).
1983-12-01
The Waste Isolation Pilot Plant: A Success Story with International Cooperation
Energy Technology Data Exchange (ETDEWEB)
The U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) administers and operates the Waste Isolation Pilot Plant (WIPP) site, which hosts a deep geologic repository for safe disposal of U.S. defense-related TRU waste and is located 42 kilometers (km) east of Carlsbad, New Mexico. CBFO also manages the National Transuranic Waste Program (NTP), which oversees TRU waste management from generation to disposal. The WIPP began receiving waste in March 1999. In some areas of broad international interest, the CBFO has developed a leading expertise through its 25-year WIPP repository and TRU waste characterization activities. In addition to participating in relevant and beneficial experiments, the CBFO will provide the international community convenient access to this information by sponsoring and hosting symposia and workshops on relevant topics and by participation in international waste management organizations and topical meetings. In recognition of the successes at WIPP, the Inter ...
2002-02-26
International Nuclear Information System (INIS)
The IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants and the corresponding Safety Guides are reviewed and compared with quality assurance (QA) practices in the IAEA Member States. The QA requirements stipulated by the Code place on the nuclear power plant owner the responsibility to establish an overall QA programme for the plant. In selecting the QA programme level for specific activities, the Code allows of a flexible approach but does not specify gradation in programme requirements. The Code is placing the burden of quality-achieving and quality-assuring functions on the task-performing organizations, namely the designers, manufacturers, constructors and plant operators. The plant owner provides for the management of the overall QA programme, surveillance of activities and verifications of the effectiveness of the constituent programmes of all project participants through programme audits and evaluations. The ...
International Nuclear Information System (INIS)
The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV ...
2004-07-01
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
Energy Technology Data Exchange (ETDEWEB)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all ...
2003-12-01
Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart
International Nuclear Information System (INIS)
The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were ...
2003-12-01
Energy Technology Data Exchange (ETDEWEB)
The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)
2006-07-01
The use of calcium silicate bricks for retrospective dosimetry
International Nuclear Information System (INIS)
The suitability of calcium silicate bricks (CSBs) for the retrospective measurement of gamma dose using luminescence techniques has been investigated. Bricks of this type are distinguished from fired clay bricks by containing negligible clay and requiring comparatively low temperature treatment during manufacture. They have been used widely in the construction f buildings in the Former Soviet Union since the 1970s but hitherto have not been used for retrospective dosimetry measurements. A procedure based on the se of the 210 deg. C thermoluminescence (TL) peak of quartz was tested with granular quartz extracted from three types of CSB, one of which had been taken from a settlement downwind of Chernobyl. The degree to which the residual geological TL signal within the temperature range of the 210 deg. C L peak had been reduced during manufacture varied with brick type; the levels of residual TL corresponded, in the samples tested, to absorbed doses n the range ...
2004-02-01
Performance testing of selected types of electronic personal dosimeters used in Sudan
International Nuclear Information System (INIS)
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
2010-12-01
Energy Technology Data Exchange (ETDEWEB)
This works evaluates by punctuation the performance in conventional Brazilian industries radiation protection area which make use of small industrial gauges and industrial radiography. It proposes, procedures for industry self-evaluation, besides a new radiation protection plans pattern for the small industrial gauges area. The data source where inspection reports of Dosimetry Radiation Protection Institute/Nuclear Energy Commission conventional Brazilian industries' radiation protection plans, beyond visitation to the inspection place. The performance evaluation has been realized both in the administrative and operational aspects of the industries. About of 60% of the industries have a satisfactory register control which does not happen to the operational control. The performance evaluation advantage is that industries may self-evaluate, foreseeing Dosimetry Radiation Protection Institute's regulation inspections, correcting ...
1999-08-01
International Nuclear Information System (INIS)
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to detect a real ...
2007-08-21
ESR dosimetry of irradiated chicken legs and chicken eggs
Energy Technology Data Exchange (ETDEWEB)
Ionising radiation induces stable free radicals in chicken bones and in the shell of chicken eggs which can be detected, by the electrons spin resonance (ESR) technique, well beyond the shelf-life of the food and can be used for dosimetry. The method usually adopted to evaluate ``a posteriori`` the dose given during the ionising radiation treatment of food, is the dose additive method. To assess the dose, the ESR signal amplitude of the irradiated food (bone or egg shell in the present case) is measured and then the dose-effect relationship is obtained by re-irradiating the sample with some additive doses (usually of 1 kGy). The dose-effect curve is back-extrapolated and the initial given dose determined. At the Istituto Superiore di Sanita (ISS), Rome, Italy, a research programme was approved two years ago aimed to, (1) study new methodological approaches for ESR dose assessment, and (2) analyse the factors which may influence the ESR readout of irradiated chicken ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
The study had three objectives: to collect information that explain the impact of the Aube storage center (C.S.A.) on environment and allow to evaluate the consequences for man, secondly, to build a referential for any future inquiry or follow-up, thirdly, to allow to the local commission of information to elaborate an information towards the side residents and local actors that take into account their questions. Trees, waters, sediments, soils, grass, products of gardens and vineyards were the object of sampling, their dosimetry is given in this report. Other dosimetry measures were made along the nuclear site and the results are equally in this report. (N.C.)
2007-07-01
CERN signed a Co-operation Agreement with the Government of Pakistan in 1994, which was followed in 1997 by a Protocol signed with the Pakistan Atomic Energy Commission (PAEC) concerning CMS magnet supports. CERN and PAEC then signed in 1998 a Memorandum of Understanding for collaboration in the construction of the CMS detector. The participation by Pakistani scientists and engineers in the CERN programme is channelled through the National Centre of Physics (NCP) established at the Quaid-i-Azzam University in Islamabad, under the terms of a 1999 Protocol to the 1994 Co-operation Agreement. The engineering and detector construction work performed under these Agreements has been of high quality, and the Pakistani participation is valued highly by the CMS collaboration. In continuation of this co-operation, Pakistan, represented by PAEC as funding agency, has now proposed to make in-kind contributions to the LHC Project, such as mechanical ...
2003-01-01
Level and Trend Uncertainties of Kyoto Relevant Greenhouse Gases in Poland. Interim Report
Energy Technology Data Exchange (ETDEWEB)
The Kyoto Protocol is often described as a good first step towards reducing greenhouse gas (GHG) emissions into the atmosphere. The Protocol endorses emissions trading, joint implementation including 'bubbling' between Annex 1 Parties, and a clean development mechanism that allows Annex 1 and non-Annex 1 Parties to act together to reduce emissions. However, the anticipated permit market will not function if uncertainties are not rigorously assessed and considered in any compliance process. With no reliable verification tool, it is impossible to effectively assess the different mechanisms and activities mentioned under the Protocol. Thus, it is very important to study the uncertainties underlying the Kyoto relevant GHGs, here with reference to Poland, because without the consideration of uncertainty robust verification can not occur. This paper presents information about the data used in the calculations as ...
2002-08-30
Energy Technology Data Exchange (ETDEWEB)
R and D of the robot control system was conducted in the following items: 1) integrated open control system, 2) remote control robot manipulation language, 3) human factor robot use built-in LAN system, 4) built-in actuator driver. In 1), there were some problems to be pointed out around the system, but the effectiveness was confirmed as system architecture of each verification item. In 2), development/design were made of RCML(R-Cube Manipulation Language) as a remote robot manipulation language, telecommunication protocol, and the experimental system, and the international standardization was targeted. In 3), the R and D was conducted of the realtime telecommunication protocol which clears the standards for the distributed control required for construction of human factor robot and the advanced realtime micro-controller, ULSI, which is the one that the protocol was made IC. In 4), an intelligent connector for built-in ...
1998-03-01
A Time-Slotted On-Demand Routing Protocol for Mobile Ad Hoc Unmanned Vehicle Systems
Energy Technology Data Exchange (ETDEWEB)
The popularity of UAVs has increased dramatically because of their successful deployment in military operations, their ability to preserve human life, and the continual improvements in wireless communication that serves to increase their capabilities. We believe the usefulness of UAVs would be dramatically increased if formation flight were added to the list of capabilities. Currently, sustained formation flight with a cluster of UAVs has only been achieved with two nodes by the Multi-UAV Testbed at the Massachusetts Institute of Technology. (Park, 2004) Formation flight is a complex operation requiring the ability to adjust the flight patterns on the fly and correct for wind gusts, terrain, and differences in node equipment. All of which increases the amount of inner node communication. Since one of the problems with MANET communication is network congestion, we believe a first step towards formation flight can be made through improved inner node communication. We have investigated ...
2007-04-01
sup 131 I treatment of thyroid papillary carcinoma in a patient with renal failure
Energy Technology Data Exchange (ETDEWEB)
Procedures for {sup 131}I ablation in renal failure are not known. In one patient receiving dialysis, detailed dosimetry and health safety aspects were obtained. The results showed insignificant contamination of equipment, but a surprisingly significant reduction in biologic half-life of {sup 131}I due to efficient dialysis extraction. The data indicate that {sup 131}I ablation can be done safely and easily during dialysis but that much higher {sup 131}I doses must be used to achieve equivalent results to those obtained in patients with normal renal function.
1990-12-15
Review of electron beam therapy physics
Energy Technology Data Exchange (ETDEWEB)
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
2006-07-07
Organ doses and integral doses in X-ray diagnosis of the chest and of the head
International Nuclear Information System (INIS)
Organ and tissue doses and integral doses in patients due to diagnostic x-ray examinations of the chest and of the head will be presented. These data have been obtained by measuring the dose distributions in man phantoms by LiF-dosimetry. The data will be compared with data obtained by Monte-Carlo calculations. To obtain average organ doses for a special type of examination for the population or for a specified subpopulation in the variation of the exposure, data due to the different techniques used by the different radiologists has to be known. Such data will be presented. The results of the investigation will be discussed in connection with the concept of the 'somatic significant.
1977-04-01
International Nuclear Information System (INIS)
Nuclear forensics is the analysis of nuclear materials recovered from either the capture of unused materials, or from the radioactive debris following a nuclear explosion and can contribute significantly to the identification of the sources of the materials and the industrial processes used to obtain them. In the case of an explosion, nuclear forensics can also reconstruct key features of the nuclear device. Nuclear forensic analysis works best in conjunction with other law enforcement, radiological protection dosimetry, traditional forensics, and intelligence work to provide the basis for attributing the materials and/or nuclear device to its originators. Nuclear forensics is a piece of the overall attribution process, not a stand-alone activity
2010-02-01
Luminescence characteristics of LiCaAlF6:Eu phosphor
British Library Electronic Table of Contents (United Kingdom)
A simple method for preparing LiCaAlF6:Eu2+ phosphor is reported. Photoluminescence (PL) and thermoluminescence (TL) studies were carried out. The TL sensitivity of the phosphor is nearly twice that of CaSO4:Dy TLD phosphor. Several other properties required for TL dosimetry are superior as well. It is suggested that the phosphor can be a suitable replacement for CaSO4:Dy. (Copyright 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
A 2D matrix allows a fairly rapid verification of irradiation parameters transferred on computer processing equipment without expanding the dosimetry means to implement. Associated to 'Multicheck and Verisoft' software it will handle some of the regulatory recommendations of the A.F.S.S.A.P.S. for quality control of accelerators and ensure the traceability of testing carried out. (N.C.)
2007-11-15
INEEL BNCT research program. Annual report, January 1, 1996--December 31, 1996
Energy Technology Data Exchange (ETDEWEB)
This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.
1997-04-01
INEEL Advanced Radiotherapy Research Program Annual Report 2001
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
2002-04-01
INEEL Advanced Radiotherapy Research Program Annual Report 2001
Energy Technology Data Exchange (ETDEWEB)
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
2002-04-30
International Nuclear Information System (INIS)
During one year more than 40,000 items of information on radiation exposure of personnel involved in the handling of radiation sources and more than 5,000,000 items on irradiation of other people are collected in the authors' laboratory. Considerable progress in assessment of mean annual gonad dose of genetically sifnificant dose was attained by means of an algorithm for a personal computer. This simple and inexpensive system has led to a higher accuracy in the application of protective measures. (author).
1985-10-22
Video equipment of tele dosimetry and audio
International Nuclear Information System (INIS)
To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The system requires of an electric power socket, and the ...
2007-07-01
Particokinetics In Vitro: Dosimetry Considerations for In Vitro Nanoparticle Toxicity Assessments
Energy Technology Data Exchange (ETDEWEB)
The rapid growth in the use of in vitro methods for nanoparticle toxicity assessment has proceeded with limited consideration of the unique kinetics of these materials in solution. Particles in general and nanoparticles specifically, diffuse, settle and agglomerate in cell culture media as a function of several systemic and particle factors: media density and viscosity, particle size, shape and density. Cellular dose then is also a function of these factors as they determine the rate of transport of nanoparticles to cells in culture. Here we develop and apply the principles of particokinetics and dosimetry in vitro and outline an approach for simulation of nanoparticle particokinetics in cell culture systems. We illustrate that where equal mass concentrations (?g/ml) imply equal doses for dissimilar materials, the corresponding particle number or surface area concentration doses differ by orders of magnitude. When rates of diffusional and gravitational particle ...
2007-02-01
Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy
Energy Technology Data Exchange (ETDEWEB)
High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation dosages in the phantom. ...
2003-07-01
Discrepancies in molar extinction coefficients of Fe"3"+ in Fricke dosimetry
International Nuclear Information System (INIS)
Values of the chemical yield, G, and of the molar extinction coefficient, epsilon, for Fricke dosimetry, have been recommended by ICRU. For epsilon, the value in ICRU Reports 17 and 21, 2205 1.mol"-"1.cm"-"1, based on an analysis of 83 reported values. It was suggested that, where neither a careful wavelength calibration nor absorbance linearity checks had been performed, a standard error of 1.5% should be assumed; otherwise 0.15% could be accepted. Alternatively, the accuracy in applying this chemical dose meter was considered improved if there was an independent determination of epsilon with the same spectrophotometer as was used for the determination of the optical density of irradiated Fricke solution. The accuracy claimed for both methods remains questionable, since no complete argumentation could be given for the differences of up to 13% in the published values. Taking into account the discussion of the sources of error by Bryant, Broszkiewicz and Ellis, we ...
1977-12-09
British Library Electronic Table of Contents (United Kingdom)
A multi-technique approach was employed to study a decorated Egyptian wooden sarcophagus (XXV?XXVI dynasty, Third Intermediate Period), belonging to the Museo del Vicino Oriente of the Sapienza University of Rome. Portable non-invasive unilateral NMR was applied to evaluate the conservation state of the sarcophagus. Moreover, using unilateral NMR, a non-invasive analytical protocol was established to detect the presence of organic substances on the surface and/or embedded in the wooden matrix. This protocol allowed for an educated sampling campaign aimed at further investigating the state of degradation of the wood and the presence of organic substances by 13C cross polarization magic angle spinning (CPMAS) NMR spectroscopy. The composition of the painted layer was analysed by optical micr...
2011-01-01
System and method for non-destructive evaluation of surface characteristics of a magnetic material
Energy Technology Data Exchange (ETDEWEB)
A system and a related method for non-destructive evaluation of the surface characteristics of a magnetic material. The sample is excited by an alternating magnetic field. The field frequency, amplitude and offset are controlled according to a predetermined protocol. The Barkhausen response of the sample is detected for the various fields and offsets and is analyzed. The system produces information relating to the frequency content, the amplitude content, the average or RMS energy content, as well as count rate information, for each of the Barkhausen responses at each of the excitation levels applied during the protocol. That information provides a contiguous body of data, heretofore unavailable, which can be analyzed to deduce information about the surface characteristics of the material at various depths below the surface.
1994-05-17
Secure Direct Communication Based on Non-Orthogonal Entangled Pairs and Local Measurement
We propose a quantum secure direct communication scheme based on non-orthogonal entangled pairs and local measurement. In this scheme, we use eight non-orthogonal entangled pairs to act as quantum channels. Due to the non-orthogonality of the quantum channels, the present protocol can availably prohibit from all kinds of valid eavesdropping and acquire a secure quantum channel. By local measurement, the sender acquires a secret random sequence. The process of encoding on the random sequence is identical to the one in one-time-pad. So the present protocol is secure. Even for a highly lossy channel, our scheme is also valid. The scheme is feasible with present-day techniques.
2008-12-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Background: Premature ovarian failure is diagnosed with a picture of amenorrhea, elevated follicle-stimulating hormone (FSH), and age under 40 years. Twenty percent (20%) of patients with premature ovarian failure have a concomitant autoimmune disease. Cases of premature ovarian failure associated with Sj?gren syndrome have been reported in the literature. Patient and method: We report a case of a 42-year-old white woman with Sj?gren syndrome and premature ovarian failure who underwent a reversal of her premature ovarian failure and restoration of normal menses using an elimination diet protocol. The patient was diagnosed with her rheumatological condition in 2005 and started on disease-modifying antirheumatoid drugs, which were taken intermittently due to a concern over medicatio...
2010-01-01
Oral rush desensitization to egg: efficacy and safety
British Library Electronic Table of Contents (United Kingdom)
Summary Background Current management of egg allergy relies on egg elimination from the diet. It does not protect patients from reactions after accidental ingestion of the food and it has a negative influence on quality of life. To solve these problems, some desensitization protocols have been described that are safe and effective, but only one study of a rush regimen for egg with a small patient sample has been published. Objective To evaluate the safety, efficacy and immunologic effects of an oral rush desensitization protocol for immediate egg allergy. Methods Subjects aged 5 years or older with symptomatic IgE-mediated allergy to hen's egg underwent a 5-day oral tolerance induction regimen and were subsequently maintained on a regular egg intake. The variables studied were the reaction...
2011-01-01
Netrawalm: Network Based Resource Aware Application Layer Multicast for Multiparty Video Conference
IP Multicast is one of the most absolute method for large bandwidth Internet applications such as video conference, IPTV, E-Learning and Telemedicine etc., But due to security and management reason IP Multicast is not enabled in Internet backbone routers. To achieve these challenges, lot of Application Layer Multicast (ALM) has been proposed. All the existing protocols such as NICE, ZIGZAG and OMNI are trying to reduce average delay by forming a Multicast tree. But still that problem has not been addressed fully. We are proposing a new protocol called NetRawALM, which will address the average delay, Reliability between nodes, Scalability of conference, Heterogeneity and resilient data distribution for real time multimedia applications by constructing the Network based Resource aware Multicast tree algorithm. This is very dynamic and decentralised. The proposed architecture is a LAN aware; it is used to reduce Internet Traffic.
2011-01-01
High-dose insulin: A consecutive case series in toxin-induced cardiogenic shock
British Library Electronic Table of Contents (United Kingdom)
Context. Cardiovascular medication overdoses can be difficult to treat. Various treatment modalities are currently recommended. Objective. To describe patient outcomes and adverse events of high-dose insulin therapy in consecutive overdose patients in cardiogenic shock after implementation of a high-dose insulin protocol (1-10 U/kg/h, while avoiding or tapering off vasopressors). Methods. This is an observational consecutive case series of patients identified from a registry. Data were collected by retrospective chart review of patients treated by our toxicology service with this protocol from February 2007 until March 2010. Results. Twelve patients were treated with high-dose insulin. The mean age was 36.5 years (SD 11.7). Seven patients had pre-existing vasopressor therapy, and all were ...
2011-01-01
Extensions to the VME hardware and software standards for the physics community
Energy Technology Data Exchange (ETDEWEB)
With the ubiquitous availability of commercial VME modules and interface chips many experiments in all branches of Experimental Physics are turning to VME as the module packaging and backplane protocol of choice for application specific modules. The current VME backplane, electrical, and mechanical standards are clearly lacking when it comes to implementing the analogue and digital front end modules that Physics experiments rely on to provide the needed high speed and intelligent solutions to their data collection requirements. To address these needs the European ESONE and American VME-P committees are collaborating with the ANSII and ISO standards committees, and the VME VITA/VSO manufacturers associations, to define standard extensions to the VME protocols for such HEP needs as ``sparse data scans``, standard uses and implementations of previously user defined pins and connectors, standardization of the 9U form factor VME cards etc. This ...
1995-10-01
British Library Electronic Table of Contents (United Kingdom)
Teleost gut associated lymphoid tissue (GALT) consists of leucocyte populations located both intraepithelially and in the lamina propria with no structural organization. The present study aims to assess different protocols for the isolation of GALT cells from an important fish species in the Mediterranean aquaculture, the gilthead seabream. Mechanical, chemical and enzymatic treatments were assayed. Nylon wool columns and continuous density gradients were used for further separation of cell subpopulations. Light microscopy and flow cytometry showed that the highest density band (HD) consisted of a homogeneous lymphocytic population, whereas the intermediate density band (ID) corresponded to epithelial and secretory cells and some lymphocytes. Respiratory burst activity of total cell suspen...
2007-01-01
An exergy based test protocol for truncated pyramid type solar box cooker
British Library Electronic Table of Contents (United Kingdom)
Developing a test standard/protocol for solar box type cookers has drawn a considerable interest among the researchers throughout the world. Recent publications on solar cookers emphasize the need of introducing the thermal performance indicators determined through exergy analysis. In the present paper, the time variation of instantaneous exergy output and energy output as function of its temperature and also of the instantaneous ambient temperature have been reported for truncated pyramid type solar box cooker and compared with those of box type cooker. Further, variations in the exergy lost with temperature difference have been depicted for the selected water temperature range from 60 degreeC to 95 degreeC. Based on this study, quality factor, exergy temperature difference gap product, a...
2011-01-01
An efficient quantum secure direct communication scheme with authentication
In this paper an efficient quantum secure direct communication (QSDC) scheme with authentication is presented, which is based on quantum entanglement and polarized single photons. The present protocol uses Einstein-Podolsky-Rosen (EPR) pairs and polarized single photons in batches. A particle of the EPR pairs is retained in the sender's station, and the other is transmitted forth and back between the sender and the receiver, similar to the ``ping-pong'' QSDC protocol. According to the shared information beforehand, these two kinds of quantum states are mixed and then transmitted via a quantum channel. The EPR pairs are used to transmit secret messages and the polarized single photons used for authentication and eavesdropping check. Consequently, because of the dual contributions of the polarized single photons, no classical information is needed. The intrinsic efficiency and total efficiency are both 1 in this scheme as almost all of the ...
2007-07-01
International Nuclear Information System (INIS)
Naturally occurring radionuclides are present in most material. The most common naturally occurring radionuclides in material are those of the uranium and thorium series and potassium-40. This material is commonly referred to as Naturally Occurring Radioactive Material (NORM). In some material the levels of naturally occurring radionuclides are significantly higher, to the extent that regulatory control may be required for radiation protection purposes. Regulation of NORM presents a range of new challenges for both regulators and operators. Unlike more traditional industries dealing with radionuclides, NORM industries have generally not had any radiological oversight and, for example, are not equipped for radiological monitoring. Some consumer goods containing NORM, which have not traditionally been considered as a radiological problem (such as some fertilizers), may require regulation and this may have social and economic consequences. The transport and disposal of NORM are also a ...
2002-09-23
Towards a recovery of the ozone layer?; Vers un retablissement de la couche d'ozone?
Energy Technology Data Exchange (ETDEWEB)
Regularly considered as the 'success story' of the world environmental policy, the regulation relative to ozone destructive products should allow a recovery of the ozone layer around the middle of the 21. century. This article analyzes how, two decades after the signature of the Montreal protocol, such forecasts are still valid and how new parameters, like the increase of the greenhouse effect, will influence this recovery. (J.S.)
2005-02-01
The renaissance of solar homes; Le renouveau des maisons solaires
Energy Technology Data Exchange (ETDEWEB)
This publication of the Areva Group, a world nuclear industry leader, provides information on the energy in many domains. This issue deals with the nuclear fuel cycle, the biofuels, the everyday geothermal power, the Unites States energy supply and types, the Bertrand Picard solar aircraft, the kyoto protocol and the wind power leaders. A special chapter is devoted to the renaissance of solar homes. (A.L.B.)
2004-07-01
Recently, Wang et al. proposed a three-party simultaneous quantum secure direct communication (3P-SQSDC) scheme with EPR pairs, which enables three involved parties to exchange their secret messages simultaneously by using an EPR pair. This work proposed an enhancement on Wang et al.'s scheme. With the enhancement, the communications in the improved 3P-SQSDC can be paralleled and thus improves the protocol efficiency.
2011-01-01
UK PubMed Central (United Kingdom)
BackgroundHamstring injuries are the most common injury in Australian Rules football. It was the aims to investigate whether a sports chiropractic manual therapy intervention protocol...Full Text Available
UK PubMed Central (United Kingdom)
A two-step purification protocol was used in an attempt to separate the constitutive NAD(P)H-nitrate reductase [NAD(P)H-NR, pH 6.5; EC 1.6.6.2] activity from the nitric oxide and nitrogen dioxide (NO(x))...Full Text Available
1988-10-01
UK PubMed Central (United Kingdom)
BackgroundMany emergency ambulance calls are for older people who have fallen. As half of them are left at home, a community-based response may often be more appropriate than hospital...Full Text Available
British Library Electronic Table of Contents (United Kingdom)
The heterogeneous solid catalyst, mercaptopropylsilica (MPS), has been prepared by a modified procedure in water and its structure confirmed by solid state carbon-13 CP-MAS NMR spectrum. This catalyst has been efficiently utilized for the synthesis of a wide variety of tri-, tetrasubstituted imidazoles and their bis-analogues at room temperature. The protocol was further explored for the synthesis of the drug trifenagrel.
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The Rocky Flats Plant, located approximately 26 km northwest of downtown Denver, Colorado, has developed an emergency response atmospheric dispersion model for complex terrain applications. Plant personnel would use the model, known as the Terrain-Responsive Atmospheric Code (TRAC) (Hodgin 1985) to project plume impacts and provide off-site protective action recommendations to the State of Colorado should a hazardous material release occur from the facility. The Colorado Department of Health (CDH) entered into an interagency agreement with the Rocky Flats Plant prime contractor, EG&G Rocky Flats, and the US Department of Energy to evaluate TRAC as an acceptable emergency response tool. After exhaustive research of similar evaluation processes from other emergency response and regulatory organizations, the interagency committee devised a formal acceptance process. The process contains an evaluation protocol (Hodgin and Smith 1992), descriptions of ...
1993-10-01
Quantum information approach to the ultimatum game
The paper is devoted to quantization of extensive games with the use of both the Marinatto-Weber and the Eisert-Wilkens-Lewenstein concept of quantum game. We revise the current conception of quantum ultimatum game and we show why the proposal is unacceptable. To support our comment, we present the new idea of the quantum ultimatum game. Our scheme also makes a point of departure for a protocol to quantize extensive games.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Governments around the world will soon make decisions on policies that could determine the fate of the ozone layer-the Earth's shield from harmful ultraviolet radiation. The Vienna Convention for the Protection of the Ozone Layer, signed on March 22, 1985, created a framework for scientific cooperation and information exchange that will form the basis for a protocol for controlling substances thought to threaten the ozone layer. As of mid-1987, 29 countries had signed the Convention, including the major producers and users of chlorofluorocarbons (CFCs), the most important of suspect chemicals.
1987-12-01
UK PubMed Central (United Kingdom)
The NSABP B-32 trial is examining whether patients with initially negative sentinel lymph nodes (SLNs) who have occult metastases detected on deeper levels and cytokeratin immunohistochemistry...Full Text Available
2009-11-01
Late effects of "2"3"9Pu administered at representative stages of gestation
International Nuclear Information System (INIS)
The protocol for a systematic comprehensive study of the influence of prenatal exposure on the tumorigenic and other adverse effects of "2"3"9Pu is described. The study has been initiated, all animals have been weaned, and postnatal function is being evaluated, although results are not yet available.
1977-05-01
Initial results of the CD-1 reliable multicast experiment
Energy Technology Data Exchange (ETDEWEB)
During the past year, an experiment has been underway to test use of reliable multicast capabilities for transmission of continuous data in the Global Communication Infrastructure. For the experiment a version of the CD-1 protocol was multicast enabled. The experiment has demonstrated the feasibility of transmitting data in a multicast mode over the GCI. In the case of the Comprehensive Nuclear Test-Ban Treaty the sender could be the station and the receivers the International Data Center (IDC) and one or more National Data Centers (NDC). The potential advantages of multicasting include (a) the timely receipt of the data by the IDC and the host NDC and (b) the simultaneous availability of the raw station data at, at least, two locations. The latter, by introducing redundant data paths, decreases the probability of loss of station data due to a potential failure of a single data receiver. This experiment is only one element of a needed more thorough assessment of ...
2000-09-29
Environmental Research Database
Objectives1) To establish a protocol for transfection of immortalised type I cells with SiRNA and its effect on cell viability; 2) To optimise silencing of genes involved in endocystosis using SiRNA and confirm successful transfection with western blotting; 3) To investigate the effect of gene silencing on uptake of flourescently-labelled latex nanoparticles.DescriptionTo investigate the mechanisms of particle uptake.
2009-01-31
Energy Technology Data Exchange (ETDEWEB)
The Kyoto Protocol attempts through political negotiations to guide participating industrialized countries' greenhouse gas (GHG) emissions from a positive growing trend, to reach a peak point (or turning point), and then be reduced to a negative growth. That means the relationship between decreasing GHG emissions and economic growth may be described by an inverted-U curve (or called a bell-shaped curve), which is consistent with the concept of the Environmental Kuznets Curve (EKC) hypothesis. This research observed that the economic development and GHG emissions in Economies in Transition (EITs) exhibit a hockey-stick curve trend (or called quasi-L-shape curve), that also generates a lot of 'hot air' which is significant to the implementation of the Kyoto Protocol. In addition, through the analysis of single-country time series data and GDP data, this research demonstrated that statistical data for most of the Annex ...
2008-01-15
Energy Technology Data Exchange (ETDEWEB)
The Kyoto Protocol attempts through political negotiations to guide participating industrialized countries' greenhouse gas (GHG) emissions from a positive growing trend, to reach a peak point (or turning point), and then be reduced to a negative growth. That means the relationship between decreasing GHG emissions and economic growth may be described by an inverted-U curve (or called a bell-shaped curve), which is consistent with the concept of the Environmental Kuznets Curve (EKC) hypothesis. This research observed that the economic development and GHG emissions in Economies in Transition (EITs) exhibit a hockey-stick curve trend (or called quasi-L-shape curve), that also generates a lot of 'hot air' which is significant to the implementation of the Kyoto Protocol. In addition, through the analysis of single-country time series data and GDP data, this research demonstrated that statistical data for most of the Annex ...
2008-01-15
Experimental realization of Dicke states of up to six qubits for multiparty quantum networking
We report the first experimental generation and characterization of a six-photon Dicke state and demonstrate its remarkable versatility by projecting out four- and five-photon Dicke states, in addition to four-photon GHZ- and W-states. These multipartite states are studied by developing experimentally favorable characterization tools. Furthermore, we show that Dicke states have interesting applications in multiparty quantum networking protocols such as open-destination teleportation, telecloning and quantum secret sharing.
2009-01-01
UK PubMed Central (United Kingdom)
Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol...Full Text Available
1995-11-01
UK PubMed Central (United Kingdom)
PurposeUsing a retrospective analysis of treatment plans submitted from multiple institutions accruing patients to the RTOG #0236 non-small cell SBRT protocol, this...Full Text Available
2009-03-15
DEVELOPMENT OF CONTINUOUS SOLVENT EXTRACTION PROCESSES FOR COAL DERIVED CARBON PRODUCTS
Energy Technology Data Exchange (ETDEWEB)
The purpose of this DOE-funded effort is to develop continuous processes for solvent extraction of coal for the production of carbon products. These carbon products include materials used in metals smelting, especially in the aluminum and steel industries, as well as porous carbon structural material referred to as ''carbon foam'' and carbon fibers. During this reporting period, efforts have focused on the facility modifications for continuous hydrotreating, as well as developing improved protocols for producing synthetic pitches.
2005-08-11
Autologous Platelet-Rich Plasma Mixed with Purified Fat Graft in Aesthetic Plastic Surgery
British Library Electronic Table of Contents (United Kingdom)
Platelet-rich plasma (PRP) is a platelet concentrate that has widely been used to accelerate the healing of soft and hard tissues. The preparation of PRP has been described by several authors. Preparation protocols vary from system to system, depending on the concentration of different integrating proteins. The objective of this article is to describe the principal use of PRP mixed with fat grafts in aesthetic plastic surgery.
2009-01-01
XML schema for atomic and molecular data. Summary report of consultants' meeting
International Nuclear Information System (INIS)
Advanced developments in computer technologies offer exciting opportunities for new distribution tools and applications in various fields of physics. The convenient and reliable exchange of data is clearly an important component of such applications. Therefore, in 2003, the A+M Data Unit initiated within the collaborative efforts of the DCN (Data Centre Network) a new standard for atomic, molecular and particle surface interaction data exchange (AM'PSI) based on XML (eXtensible Markup Language). A working group composed of staff from the IAEA, NIST, ORNL and Observatoire Paris-Meudon meets biannually to discuss progress made on the XML schema, and to foresee new developments and actions to be taken to promote this standard for AM/PSI data exchange. (author)
2007-12-06
Second international symposium on nuclear power plant life management. Book of extended synopses
International Nuclear Information System (INIS)
The world's fleet of nuclear power plants is, on average, more than 20 years old. Even though the design life of a nuclear power plant is typically 30-40 years, it is quite feasible that many plants will be able to operate in excess of their design lives, provided that nuclear power plant engineers demonstrate by analysis, trending, equipment and system upgrades, increased vigilance, testing and ageing management that the plant will operate safely. In the operation of nuclear power plants, safety should be always the prime consideration. Plant operators and regulators must always ensure that plant safety is maintained, and where possible enhanced, during a plant's operating lifetime. Nuclear power plant life management (PLiM) has gained increased attention over the past decade, and effective ageing management of systems, structures and components (SSCs) is a key element in PLiM for the safe and reliable long term operation of nuclear power plants. A PLiM programme is an effective tool ...
2007-10-15
Report of the technical committee meeting 1997 annual workshop on ASSET experience and feedback
International Nuclear Information System (INIS)
Papers and presentations were made by all participating countries and provided a wide range of perspectives on the use of the ASSET methodology. Generally, the views expressed were positive, however, there were comments on areas were the service could be improved or enhanced. The workshop was divided into three task groups to analyze the self-assessments conducted at Krsko NPP, Slovenia; Dukovany NPP, Czech Republic; and Balakovo NPP, Russian Federation. In addition, they were asked to comment on the recommendations on the ASSET service made by the Consultants' Meeting of 26-30 August 1996 on ''Performance of the IAEA programme on Operational Safety Services''. A presentation was made by Mr. B. Thomas to remind delegates of the ASSET methodologies, and Mr. V. Sivokon demonstrated the latest developments of computer software available for assisting in the plant Self-Assessment process. Refs, figs, tabs.
1997-06-24
International Nuclear Information System (INIS)
The IAEA Assessment of Safety Significant Events Team (ASSET) report presents the results of an ASSET team's assessment of their investigation of the effectiveness of the plant for prevention of incidents since 1990 at Zaporozhe nuclear power plant. The results, conclusions and suggestions presented herein reflect the views of the ASSET experts. They are provided for consideration by the responsible authorities in Ukraine. The ASSET team's views presented in this report are based on visits to the plant, on review of documentation made available by the operating organization and on discussions with utility personnel. The report is intended to enhance operational safety at Zaporozhe by proposing improvements to the policy for the prevention of incidents at the plant. The report includes, as a usual practice, the official response of the operating organization as well as of the regulatory body to the ASSET recommendations. Figs.
2003-11-01
International Nuclear Information System (INIS)
Increasing threat by terrorists for a possible nuclear attack is particularly alarming in recent years. The likelihood of such an event is highly uncertain but cannot be ruled out. The consequence of such an event would be highly disastrous and the implications could be far-reaching both socially and politically. It is feared that significant amount of nuclear weapons materials may be kept under poor security. Therefore, there is a greater demand with utmost priority to curb nuclear terrorism by adapting proper security measures. One of the most important measures is to stop illicit trafficking of nuclear materials which are the source of building nuclear explosive devices. According to the IAEA illicit trafficking database (ITDB) report, a total number of 252 incidents were reported in 2006, of which 150 occurred in 2006 and the remaining 102 had taken place prior to that year, mainly in 2005
2010-11-15
Nuclear forensic investigations with a focus on plutonium
International Nuclear Information System (INIS)
Since the beginning of the 1990s when the first seizures of nuclear material were reported, the IAEA has recorded over 200 cases of illicit trafficking of nuclear materials. Despite the decreasing frequency of nuclear material seizures, particularly the ones involving weapons-grade material, the issue continues to attract public attention and is a reason for concern due to the hazard associated with such materials. Once illicitly trafficked nuclear material has been intercepted, the questions of its intended use and origin are to be addressed. Especially the origin is of prime importance in order to close the gaps and improve the physical protection at the sites where the theft or diversion occurred. To answer these questions, a dedicated nuclear forensics methodology has been developed. In this paper an overview is given on the methodologies used, on the past and on-going developments and on the experience gathered. Some selected examples shall illustrate the ...
2007-10-11
Guidebook on design, construction and operation of pilot plants for uranium ore processing
International Nuclear Information System (INIS)
The design, construction and operation of a pilot plant are often important stages in the development of a project for the production of uranium concentrates. Since building and operating a pilot plant is very costly and may not always be required, it is important that such a plant be built only after several prerequisites have been met. The main purpose of this guidebook is to discuss the objectives of a pilot plant and its proper role in the overall project. Given the wide range of conditions under which a pilot plant may be designed and operated, it is not possible to provide specific details. Instead, this book discusses the rationale for a pilot plant and provides guidelines with suggested solutions for a variety of problems that may be encountered. This guidebook is part of a series of Technical Reports on uranium ore processing being prepared by the IAEA's Division of Nuclear Fuel Cycle and Waste Management. 42 refs, 7 figs, 3 tabs.
International Nuclear Information System (INIS)
The risks from mining and processing of ores is reviewed on a generic basis with particular reference to some of the confusions which can arise due to lack of consistency or common logic in the use of exclusion, exemption and clearance. The difference in exclusion and exemption are challenged by comparing doses received in high background radiation areas and the doses received from a mining practice. The common principle of risk to the human species is not applied consistently. The differences between IAEA recommendations and local regulatory conditions are compared, and the use of exemption levels as clearance levels is considered. A case study on management of mine tailings is presented with special focus on the use of clearance levels. In all areas of review the interpretation of regulation is subject to confusion resulting from inconsistencies which can distort free market economics. (author).
1997-05-06
International Nuclear Information System (INIS)
The Co-ordinated Research Programme (CRP) on ''Isotope-Aided Studies on the Bioavailability of Iron and Zinc from Human Diets'' was initiated by the IAEA in 1990, and presently encompasses participating institutes in 11 countries. A summary of the discussions that took place during thr second Research Co-ordination Meeting held in Hyderabad, India, between 16-20 November 1992, is given in this report together with 12 working papers (progress reports) presented by individual participants. A separate abstract was prepared for each of these papers. Refs, figs and tabs.
1992-11-16
Energy Technology Data Exchange (ETDEWEB)
The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).
1993-12-31
International Nuclear Information System (INIS)
The calculations presented are based on RELAP5/MOD2-3 input for VVER 440/213 Bohunice NPP, developed within the framework of IAEA TC Project by an international team of specialists from CSFR, Hungary, Bulgaria and Poland. Project activities were condentrated on input data refinement and testing. Several cases were calculated using the latest version of RELAP5/MOD2 provided by RMA, Albuquerque to investigate some modelling assumptions, such as break location, geometrical representation of secondary circuit piping as well as the effect of deactivation of the signal controlling the SG isolation valves. (2 refs., 21 figs., 2 tabs.).
1992-09-29
An analysis strategy for safeguards use of optical satellite imagery
International Nuclear Information System (INIS)
This paper outlines conceptual framework for safeguards remote sensing, and suggests a strategy for overcoming the challenges to full exploitation of all types of optical satellite imagery. Since the introduction of commercial open-source high-resolution satellite imagery in 1999, it has become an important tool for verification of declarations, baseline mapping, detection and monitoring of changes and investigation of undeclared activities. Its use is still relatively restricted, but there is a growing demand for wider satellite reconnaissance support, and the Satellite Image Analysis Unit (SIAU) has recently been expanded in response. For a number of reasons, IAEA safeguards use of satellite imagery is largely based on visual interpretation by experienced image analysts of high-resolution monochromatic imagery to monitor and characterize buildings and structures on safeguards sites. The very wide range of remote sensing capabilities could be more fully exploited. ...
2006-10-16
An MS-DOS-based program for analyzing plutonium gamma-ray spectra
Energy Technology Data Exchange (ETDEWEB)
A plutonium gamma-ray analysis system that operates on MS-DOS-based computers has been developed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra for plutonium isotopics. The program titled IAEAPU consists of three separate applications: a data-transfer application for transferring spectral data from a CICERO multichannel analyzer to a binary data file, a data-analysis application to analyze plutonium gamma-ray spectra, for plutonium isotopic ratios and weight percents of total plutonium, and a data-quality assurance application to check spectral data for proper data-acquisition setup and performance. Volume 3 contains the software listings for these applications.
1989-09-07
Treatment for dismantled radioactive solid waste from the TRIGA Mark-2 and 3
Energy Technology Data Exchange (ETDEWEB)
Radioactive wastes are generally classified into 3 type depending on their physical property: liquid, solid and gaseous type. State-of -the art concerning liquid waste treatment has already been published; KAERI/TR-1315/99. Solid wastes classification package and treatment method will be studied to effectively manage them during the practical decommissioning work. All of the spent fuel produced during the operation of the TRIGA Mark-2 and 3 have been transported to the US last year, 1998, according to the spent fuel management strategy set-up by the US government for the non-proliferation of nuclear energy. Solid wastes are mainly all equipment existing inside of the reactors, activated concrete among the bio-shielded concrete, pipes, pimps, resin filter and it's housings, heat-exchangers, liquid waste storage tanks, to radioactive waste storage treatment facilities and so on. Solid wastes are generally low-level. They are classified according to the national regulation and ...
1999-06-01
The role of networking for nuclear education
International Nuclear Information System (INIS)
Nuclear knowledge is the basis for almost all nuclear activities, and education and training are the most fundamental means to transfer knowledge from one generation to the next. Understanding means and trends in knowledge transfer through education and training thus deserves a closer examination. In the past years, a number of trends and questions in nuclear knowledge, education and training have emerged. With declining student enrolment numbers and a general stagnation of the use of nuclear power in some of the IAEA's Member States, the issue of a slow erosion of the knowledge base and the possibility of loosing knowledge has become increasingly important, in particular if seen against the background of a possible renaissance of nuclear power in the future. In other Member States, an expansion of nuclear power is expected, with a corresponding need for human resources. As a result, in many Member States education and training of the next generation and succession ...
2004-10-01
International Nuclear Information System (INIS)
The UK fully supports the objective of the Joint Convention on the Safety of Spent Fuel Management and on the Safety of Radioactive Waste Management to achieve and maintain a high level of safety worldwide in spent fuel and radioactive waste management, through the enhancement of national measures and international co-operation, including where appropriate, safety-related co-operation. The UK's Health and Safety Executive, through its Nuclear Safety Directorate (NSD), has been committed to the Convention since the initial negotiations to set up the Convention and provided the president of the first review meeting in 2003. It would be wrong of any nation to believe that they have all the best solutions to managing spent fuel and radioactive waste. The process of compiling reports for the Convention review meetings provides a structured process through which every contracting party can review its provisions against a common set of standards and identify for itself possible areas of ...
This paper is dedicated to the treatment of sludge occurring in frame of the Egyptian produced from oil and gas production. The activity levels of three radium isotopes: Ra-226 (of U-series), Ra-228 and Ra-224 (of Th-series) in the solid TENORM waste (sludge) were first evaluated and followed by a sequential treatment for all radium species (fractions) presented in TENORM. The sequential treatment was carried out based on two approaches 'A' and 'B' using different chemical solutions. The results obtained indicate that the activity levels of all radium isotopes (Ra-226, Ra-228 and Ra-224) of the environmental interest in the TENORM waste sludge were elevated with regard to exemption levels established by IAEA [International Atomic Energy Agency (IAEA), International basic safety standards for the protection against ionizing radiation and for the safety of radiation sources. GOV/2715/Vienna, 1994]. Each approach of the sequential treatment was ...
2008-04-18
Energy Technology Data Exchange (ETDEWEB)
This paper is dedicated to the treatment of sludge occurring in frame of the Egyptian produced from oil and gas production. The activity levels of three radium isotopes: Ra-226 (of U-series), Ra-228 and Ra-224 (of Th-series) in the solid TENORM waste (sludge) were first evaluated and followed by a sequential treatment for all radium species (fractions) presented in TENORM. The sequential treatment was carried out based on two approaches 'A' and 'B' using different chemical solutions. The results obtained indicate that the activity levels of all radium isotopes (Ra-226, Ra-228 and Ra-224) of the environmental interest in the TENORM waste sludge were elevated with regard to exemption levels established by IAEA [International Atomic Energy Agency (IAEA), International basic safety standards for the protection against ionizing radiation and for the safety of radiation sources. GOV/2715/Vienna, 1994]. Each ...
2009-01-30
Management of long term radiological liabilities: Stewardship challenges
International Nuclear Information System (INIS)
The IAEA attaches great importance to the dissemination of information that can assist Member States with the development, implementation, maintenance and continuous improvement of systems, programmes and activities that support the nuclear fuel cycle and nuclear applications, including management of the legacy of past practices and accidents. In this connection, the IAEA has initiated a comprehensive programme of work covering all aspects of environmental remediation: - Technical and non-technical factors, including costs, that influence environmental remediation strategies and pertinent decision making; - Site characterization techniques and strategies; - Assessment of remediation technologies; - Techniques and strategies for post-remediation compliance monitoring; - Special issues such as the remediation of sites with dispersed radioactive contamination or mixed contamination by hazardous and radioactive substances. Experience in Member ...
2006-01-01
Future needs and requirements for AMS "1"4C standards and reference materials
International Nuclear Information System (INIS)
"1"4C measurement uses a number of standards and reference materials with different properties. Historically the absolute calibration of "1"4C measurement was tied to 1890 wood, through the 'primary' standard of NBS-OxI (produced by the National Bureau of Standards, now NIST - National Institute of Standards and technology) subsequently replaced by NBS-OxII. These are both internationally calibrated and certified materials, whose "1"4C activities are known absolutely. A second tier of materials, often called secondary standards or reference materials, and including internationally recognised materials such as ANU-sucrose (now also IAEA-C6), Chinese - sucrose and the IAEA C1-C6 series, augmented by additional oxalic acid samples are also used routinely. The activity of these materials has been estimated from large numbers of measurements made by many laboratories. Recently, further natural materials from the Third and Fourth International ...
2004-08-01
Energy Technology Data Exchange (ETDEWEB)
A meeting was held on October 15, 16, 17, 1990 to discuss the state of tritium safety and environmental effects. The meeting was organized with the help of the International Energy Agency planning committee consisting of K. Steinmetz, Y. Seki, G. Nardella, and G. Vivian. Representative of tritium production facilities and heavy water reactor power production were also involved. The meeting was organized to address seven topics in tritium safety that were thought to require further work. The topics were: (1) materials science, (2) environmental models, (3) environmental model validation, (4) tritiated organic compounds, (5) human dosimetry, (6) tritium sampling and measurement, and (7) long-term environmental databases.
1991-04-18
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
The estimation of radiation dose to man from either external or internal exposure to radionuclides requires a knowledge of the energies and intensities of the atomic and nuclear radiations emitted during the radioactive decay process. The availability of evaluated decay data for the large number of radionuclides of interest is thus of fundamental importance for radiation dosimetry. This handbook contains a compilation of decay data for approximately 500 radionuclides. These data constitute an evaluated data file constructed for use in the radiological assessment activities of the Technology Assessments Section of the Health and Safety Research Division at Oak Ridge National Laboratory. The radionuclides selected for this handbook include those occurring naturally in the environment, those of potential importance in routine or accidental releases from the nuclear fuel cycle, those of current interest in nuclear medicine and fusion reactor technology, and some of ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
Cellular telephones emit a radiofrequency electromagnetic field, part of which is absorbed in the user's head. Many studies have been conducted to look for their possible health hazard to human, at the experimental, epidemiological or clinical level. After a short recall on dosimetry, the author describes the state-of-the art about harmful and irreversible effects, up to now not confirmed, and about some benign symptoms which look absolutely actual. A causal relationship of the electromagnetic field on these benign symptoms is however not proven; other, studies are running to evaluate their possible long-term consequences. Interferences with cardiac pacemakers can easily be avoided by holding the telephone handset farther than 10 cm. (author)
1999-12-01
Radiation therapy and Ewing's sarcoma in childhood
International Nuclear Information System (INIS)
Despite high local control rate in Ewing's sarcoma the exact indication of radiation therapy is still controversial as well as the choice of the target volume and the optimal dose of radiation. The importance of the quality of radiotherapy has been stressed in recently published data and has shown a significant impact on long term local control with adequate radiation therapy. The dramatic improvement of precision allowed by the conformal therapy and three dimensional dosimetry allow to expect a decrease of late effects expected for second malignancies. However, late sequelae and radio-induced osteosarcoma still remain the major side effects after radiotherapy. The authors discuss the results of the main trials on Ewing's sarcoma on the choice of dose and target volume. Surgery is still the preferred choice for small tumors if the foreseen outcome is identical. (authors). 28 refs.
International Nuclear Information System (INIS)
The book presents a very good account of all aspects of protection from ionizing radiation. The quantities and units are given and defined used in nuclear physics and dosimetry. The effects of ionizing radiation on cells and on man are described. The principles are presented of radiation protection including limits and valid regulations and decrees. Also discussed is internal irradiation and its modelling. A great part of the book is devoted to aspects of monitoring persons, the living and working environment and to the determination of internal contamination. The system of radiation protection in Czechoslovakia is described and some practical questions are discussed of protection during radiodiagnosis and radiotherapy, in the nuclear fuel cycle, in the operation of nuclear power installations and in crack detection. In conclusion a survey is given of the population exposure from various natural and artificial sources. (M.D.). 57 figs., 34 tabs., 138 refs.
1988-01-01
Photon beam modelling with Pinnacle3 Treatment Planning System for a Rokus M Co-60 Machine
International Nuclear Information System (INIS)
The basic relationships of the convolution/superposition dose calculation technique are reviewed, and a modelling technique that can be used for obtaining a satisfactory beam model for a commercially available convolution/superposition-based treatment planning system is described. A fluence energy spectrum for a Co-60 treatment machine obtained from a Monte Carlo simulation was used for modelling the fluence spectrum for a Rokus M machine. In order to achieve this model we measured the depth dose distribution and the dose profiles with a Wellhofer dosimetry system. The primary fluence was iteratively modelled by comparing the computed depth dose curves and beam profiles with the depth dose curves and crossbeam profiles measured in a water phantom. The objective of beam modelling is to build a model of the primary fluence that the patient is exposed to, which can then be used for the calculation of the dose deposited in the patient. (authors)
Energy Technology Data Exchange (ETDEWEB)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-08-01
International Nuclear Information System (INIS)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-01-01
International Nuclear Information System (INIS)
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
Measurement of skin dose in primary irradiation of maxillary sinus carcinoma
Energy Technology Data Exchange (ETDEWEB)
Subcutaneous involvement frequently occurs in maxillary sinus carcinoma. Radical resection does not include removal of the skin at risk. In standard postoperative wedge-pair treatment plans, the surface dose is dependent upon beam weighting, beam energy, and patient contour. Thermoluminescent dosimetry (TLD) measurements were performed to evaluate the surface dose of patients undergoing postoperative irradiation of maxillary sinus carcinoma following primary resection. When 60 Gy was delivered to isocenter with a 45 degrees wedge pair and 6 MV photons with 1 cm bolus, the subcutaneous tissues at risk received {approximately} 30 Gy. Based upon presented TLD measurements, supplemental electron beam therapy to the subcutaneous tissues if primarily involved should be considered.
1991-03-01
Measurement of radon daughter product burden by TLD dosemeters
International Nuclear Information System (INIS)
A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.
Health and Safety Research Division progress report for the period April 1, 1987--September 30, 1988
Energy Technology Data Exchange (ETDEWEB)
The mission of the Health and Safety Research Division (HASRD) is to provide a sound scientific basis for the measurement and assessment of human health impacts of radiological and chemical substances. Our approach to fulfilling this mission is to conduct a broad program of experimental, theoretical, and field research based on a strong foundation of fundamental physical studies that blend into well-established programs in life sciences. Topics include biomedical screening techniques, biological and chemical sensors, risk assessment, health hazards, dosimetry, nuclear medicine, environmental pollution monitoring, electron-molecule interactions, interphase physics, surface physics, data base management, environmental mutagens, carcinogens, and tetratogens.
1989-03-01
Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report
Energy Technology Data Exchange (ETDEWEB)
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
2003-04-08
Efficiency of a lead-containing tie for radiation protection of the thyroid gland
Energy Technology Data Exchange (ETDEWEB)
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).
1992-11-01
Efficiency of a lead-containing tie for radiation protection of the thyroid gland
International Nuclear Information System (INIS)
During fluoroscopy the examiner is usually protected by a radiation-reducing body shield, leaving the thyroid unprotected. The fact that the thyroid is located in a region of the neck usually covered by the shirt collar led to the idea of designing a tie with lead core, providing easy and ''decorative'' reduction of the radiation dose. Sonographic examinations were carried out in 20 volunteers (10 men, 10 women) to determine the size of the gland and its coverage by such a tie. The reduction of the surface and organ dose was assessed using film dosimetry with scattered radiation, the body of the examiner being simulated by an Alderson phantom. On average 88% of the thyroid gland surface area was covered. Surface dose was reduced to 1%, and organ dose to 10% of the value without the protection tie. (Author).
Effective dose equivalent concept in radiopharmaceutical dosimetry
Energy Technology Data Exchange (ETDEWEB)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...
1981-06-01
Effective dose equivalent concept in radiopharmaceutical dosimetry
International Nuclear Information System (INIS)
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source volumes and the re iden e times in total body and the target organs. Examples are given for the calculation of somatically effective dose equivalent for ...
Dosimetry of iodine-123 iomazenil in humans
International Nuclear Information System (INIS)
The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).
International Nuclear Information System (INIS)
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.
1987-01-01
An integrating dosimeter for pulsed radiation
A Pulsed Radiation Dosimetry System designed to measure radiation produced by particle accelerators is described. The problems associated with total-dose measurement of irregular shaped pulses of ionizing radiation have been simplified. The system responds to extremely narrow pulses of charged particles or X-rays using a pin diode as the detector. Direct readout of dose in rads (Si) is displayed on a 3-1/2 digit digital panel meter. The system will operate in either the multiple-pulse or single-pulse mode. The multiple-pulse mode would be useful in monitoring or tuning a linear accelerator. In the single-pulse mode the system will automatically display total dose of a transient event in real time and hold that measurement indefinitely or until the next measurement is made. The system features an automatic reset in either mode.
1983-12-01
International Nuclear Information System (INIS)
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. (authors)
2008-05-01
A routine chemical dosimetric system using the modified ceric sulphate dosimeter
International Nuclear Information System (INIS)
The radiolytic reduction of the Ce4+ in a 0.8N sulfuric acid was examined, with the objective of measuring large radiation doses. the ceric sulphate dosimeter was tested in the range from 1 to 20kGy. The 0.01 M sodium oxalate solution was chosen instead of the arsenious oxide solution (used in the conventional method), in order to obtain a less expensive dosimetric system than that normally use for routine chemical dosimetry. The absorption spectrum of the Ce"4"+ solution presents an absorption peak at 370 nm; the obtained molar extinction coefficients of Ce"4"+ and Ce"3"+ were 5670 and 2.7 M"-"1 cm"-"1 respectively. The purpose of this work was to establish a simple, reliable and inexpensive routine chemical dosimetric system for high doses.
1994-10-01
Energy Technology Data Exchange (ETDEWEB)
This paper reports some technical contributes related to the Kyoto Protocol and its application in Italian decision making policy. [Italian] Il presente volume raccoglie una decina di contributi tecnici originariamente preparati o commissionati dall'ENEA, Ente Nazionale per le Nuove Tecnologie, l'Energia e l'Ambiente, in vista della Conferenza Nazionale Energia e Ambiente. Questa fotografia di una situazione in rapida evoluzione e' stata preparata da esperti del settore che contribuiscono a redigere il materiale tecnico di base utilizzato dai negoziatori nazionali durante le trattative internazionali e dai responsabili nazionali per avviare il processo di presa di decisioni in materia.
2000-07-01
QoS-Aware Joint Policies in Cognitive Radio Networks
One of the most challenging problems in Opportunistic Spectrum Access (OSA) is to design channel sensing-based protocol in multi secondary users (SUs) network. Quality of Service (QoS) requirements for SUs have significant implications on this protocol design. In this paper, we propose a new method to find joint policies for SUs which not only guarantees QoS requirements but also maximizes network throughput. We use Decentralized Partially Observable Markov Decision Process (Dec-POMDP) to formulate interactions between SUs. Meanwhile, a tractable approach for Dec-POMDP is utilized to extract sub-optimum joint policies for large horizons. Among these policies, the joint policy which guarantees QoS requirements is selected as the joint sensing strategy for SUs. To show the efficiency of the proposed method, we consider two SUs trying to access two-channel primary users (PUs) network modeled by discrete Markov chains. Simulations demonstrate three ...
2010-01-01
Identification of environmental RD D needs
Energy Technology Data Exchange (ETDEWEB)
The objective of this project was to identify needs for environmental research development and demonstration projects that have the potential to improve the performance of oil and gas exploration, drilling, and production technologies for maximum recovery of domestic petroleum resources under optimal environmental and economic conditions. To achieve this objective several areas of work were addressed. The first task was to compile as much related data as possible. This was achieved by literature searches of a number of petroleum-related data bases. After acquiring sufficient background on environmental and economical areas that should be expanded, experts who are knowledgeable in these areas were contacted to further define specific issues. More than 33 identified areas were submitted to an in-house panel at NIPER to assure that the final environmental research demonstration and development needs that were selected to be expanded were unbiased and worthy of additional work. Specific ...
1991-09-01
Hyperfractionated radiotherapy with simultaneous chemotherapy in Ewing's sarcoma
International Nuclear Information System (INIS)
In 1981, the German Society of Pediatric Oncology initiated a multi-institutional study for the treatment of Ewing's sarcoma. The protocol (Cooperative Ewing's Sarcoma Study, CESS 81) consisted of four courses of a four-drug-regimen (VACA), each course taking nine weeks. Local therapy (radical surgery or resection plus irradiation or radiotherapy alone) was performed after the second course. The results of CESS 81 can be summarized as follows: VACA-chemotherapy is effective in controlling systemic disease. Initial tumor mass and response to initial chemotherapy are of major prognostic value for local control and survival. Permanent local control is a problem, especially in irradiated patients. The high local failure rate in irradiated patients in CESS 81 could be attributable to the following reasons: Late start of local therapy (after 18 weeks of chemotherapy), uneven distribution of prognostic parameters: Large tumors were more often irradiated than operated, ...
Energy Technology Data Exchange (ETDEWEB)
The United Nations Framework Convention on Climate Change (UNFCCC) was approved in 1992 to respond to the worl-wide concern about the warming of the planet. The primary target was the stabilization of the concentration of greenhouse gases in the atmosphere, in an attempt to reduce to the minimum the degradation of the environment caused by humans. By virtue of the Convention, the Parts2 are committed to reach their objectives in the reduction of the emissions. A Conference of the Parts was stablished to promote the effective application of the Convention. The third Conference of the Parts, celebrated in Kyoto (Japan, 1997) approved, by consensus, the denominated Kyoto Protocol, in which 39 developed countries and countries with economies in transition were committed to reduce their emissions of greenhouse gases between years 2008 and 2012 in a 5.2 global percent with respect to the 1990 levels. Three {sup f}lexibility mechanisms{sup w}ere stablished to help the ...
2006-07-01
Computer Network Security: Best Practices for Alberta School Jurisdictions.
This paper provides a snapshot of the computer network security industry and addresses specific issues related to network security in public education. The following topics are covered: (1) security policy, including reasons for establishing a policy, risk assessment, areas to consider, audit tools; (2) workstations, including physical security, protecting workstation components, and computer viruses; (3) the local network, including the OSI (Open Systems Interconnection) reference model, protocols, network segmentation, network management, network sniffing, and data encryption; (4) servers, including UNIX and other server operating systems; (5) remote access, including technologies, remote access servers, protocols, and authentication/authorization; (6) crackers and hackers, including threats and hacking tools/techniques; (7) Internet firewalls, including functions, issues and problems, types, rules, logs, firewall accessories, buying a ...
1999-02-01
International Nuclear Information System (INIS)
Methods: Systemic irradiation of neuroaxis is an essential part in the management of medulloblastoma, stPNET and intracranial germ cell tumors. The introduction of quality assurance programs in radiooncology assures a precise radiotherapy of target volumes and is a prerequisite to improve survival. Results: Hyperfractionated radiotherapy has the potential of increasing dose to tumor more safely without increasing the risk for late adverse effects. Pilot studies revealed excellent tumor control in medulloblastoma with acceptable acute toxicity and a long-term survival of up to 96%. In medulloblastoma stereotactic radiation techniques reveal an acceptable toxicity and promising results in tumor control in recurrent disease or as primary treatment. They are now part of future treatment protocols in case of persisting residual tumor. Radiotherapy alone in pure germinoma is continuously yielding high cure rates. In secreting germ cell tumors cisplatin containing ...
2001-09-01
Energy Technology Data Exchange (ETDEWEB)
The House Committee report describes the purpose, background, committee considerations and findings, and correspondence relating to H. Con. Res. 50, which is intended to encourage the president to pursue international negotiations relating to the ozone layer. The intent is to develop an international protocol and regulatory framework that will protect the stratosphere from the effects of chlorofluorocarbons. The report notes that some nations have already taken unilateral remedial steps, but argues the benefits of a negotiated agreement worldwide.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
This document provides information and presents data on the energy situation in many regions of Canada. The first part deals with the petroleum and the bitumen shales of Alberta (reserves, exploitation and production, environmental impacts), the second part discusses with the hydroelectricity choice of Quebec and the 2004 crisis. The nuclear situation of Ontario is presented in the third part (nuclear park, programs, uranium reserves, research and development on Candu reactors), while the fourth part deals with the renewable energies (wind power and biomass). The canadian situation facing the Kyoto protocol is discussed in the last part. (A.L.B.)
2004-12-01
Self-stabilizing K-out-of-L exclusion on tree network
In this paper, we address the problem of K-out-of-L exclusion, a generalization of the mutual exclusion problem, in which there are $\\ell$ units of a shared resource, and any process can request up to $\\mathtt k$ units ($1\\leq\\mathtt k\\leq\\ell$). We propose the first deterministic self-stabilizing distributed K-out-of-L exclusion protocol in message-passing systems for asynchronous oriented tree networks which assumes bounded local memory for each process.
2008-01-01
Protocol for the E-Area Low Level Waste Facility Disposal Limits Database
Energy Technology Data Exchange (ETDEWEB)
A database has been developed to contain the disposal limits for the E-Area Low Level Waste Facility (ELLWF). This database originates in the form of an EXCEL{copyright} workbook. The pertinent sheets are translated to PDF format using Adobe ACROBAT{copyright}. The PDF version of the database is accessible from the Solid Waste Division web page on SHRINE. In addition to containing the various disposal unit limits, the database also contains hyperlinks to the original references for all limits. It is anticipated that database will be revised each time there is an addition, deletion or revision of any of the ELLWF radionuclide disposal limits.
2006-01-31
International Nuclear Information System (INIS)
The article is an overview on atmospheric pollution in Lebanon. It presents an analysis of sources of pollution in the country and their impacts on local and global environment and describes their control. Air pollution is mainly due to the industrial, electrical and transportation sectors. Pollutants from fuel combustion are analyzed. It is estimated that in 2010, CO_2 emissions will reach 5987250 tons, SO_2 emissions is estimated to be 182950 tons, Nox to 105180 and dusts to 4965 tons. CFC consumption and measures of control according to Montreal protocol are described. Consumption of primary energy, consumption of petroleum products, quantity of petroleum in refineries and production of cement in Lebanon are also presented in tables
2000-02-01
International Nuclear Information System (INIS)
We present a simple protocol to purify a coherent-state superposition that has undergone a linear lossy channel. The scheme constitutes only a single beam splitter and a homodyne detector, and thus is experimentally feasible. In practice, a superposition of coherent states is transformed into a classical mixture of coherent states by linear loss, which is usually the dominant decoherence mechanism in optical systems. We also address the possibility of producing a larger amplitude superposition state from decohered states, and show that in most cases the decoherence of the states are amplified along with the amplitude.
2006-04-01
On the Reduction of Broadcast Traffic in Mobile Ad Hoc Networks
Many mobile ad hoc network protocols use simple flooding, in order to adapt to changes in time varying network topology. Most of the times, a network-wide flood results in redundant packets and increases network congestion, probability of packet collision, low utilization of available bandwidth, and most important, higher power consumption. In this paper, we propose a new cross-layer broadcast scheme to minimize broadcast traffic in mobile ad hoc networks. Our scheme is based on use of received signal strength indicator, RSSI, value to reduce the number of broadcast packets. The effectiveness of the proposed technique is verified using simulations.
2010-01-01
International Nuclear Information System (INIS)
This study illustrates the way to perform protocols, collect samples, and conduct laboratory analyses in order to characterize the physical properties of wood used in the industrial sector of the Valle de Aburra metropalitan area and the gains obtained by characterizing the properties of the most frequently used woods. In this investigation some of the most important sampling parameters are presented, such as taking samples in piles or accumulations of waste, handling of these samples in the laboratory and others of great importance such as the ignition point. the proposed methodology is based upon some of the international astm coal norms, for the similarity it has with wood and for the lack of information on sampling this type in wood
Lack of awareness of symptoms in people with dementia: the structural and functional basis
British Library Electronic Table of Contents (United Kingdom)
AbstractObjective To review studies investigating the brain correlates of unawareness of cognitive and behavioural symptoms in people with dementia. Design A detailed search of the literature was conducted to include all the peer-reviewed studies published in English aimed at identifying the structural or functional brain correspondents of unawareness in dementia patients. Their results were interpreted in relation to the methodological differences in terms of type of dementia studied, the protocol adopted to measure lack of awareness, the imaging techniques employed, the experimental designs and statistical analyses performed. Results Eighteen studies undertaken to explore the functional and structural correlates of unawareness of cognitive symptoms in dementia were identified. Although t...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In the framework of the negotiations on the climatic changes, beginning at Rio in 1992, the France received an UN conference from the 4 to 15 of september 2000. This conference determined the necessary actions for the Kyoto protocol validation. This document presents in two part the program of these days. The first part is devoted to the world government policy and the second part defines the french actions decided to fight against the climatic change. A glossary of the main terms adapted to the climatic change domain, is also provided. (A.L.B.)
2000-07-01
Formal Analysis of UMTS Privacy
The ubiquitous presence of mobile communication devices and the continuous development of mo- bile data applications, which results in high level of mobile devices' activity and exchanged data, often transparent to the user, makes privacy preservation an important feature of mobile telephony systems. We present a formal analysis of the UMTS Authentication and Key Agreement protocol, using the applied pi-calculus and the ProVerif tool. We formally verify the model with respect to privacy properties. We show a linkability attack which makes it possible, for individuals with low-cost equipment, to trace UMTS subscribers. The attack exploits information leaked by poorly designed error messages.
2011-01-01
Efficient quantum secure communication scheme with one-time pad
In this paper, we proposed a novel quantum secure direct communication scheme with one-time pad in stabilizer formalism. Based on the reuse of qubit sequence, an efficient secure communication of secret messages without first producing a shared secret key can be achieved. One hence may find that the amount of private key needed for quantum communication is smaller than that in the general case. Therefore, the present protocol which is feasible with the present-day techniques may be applied to quantum communication with short-length encoding.
2009-05-01
Design of intelligent nucleobases and DNA HOMO mapping.
We have designed a new nucleobase, benzodeazaadenine (BDA) that has a stronger charge transport ability than guanine and is not destroyed during charge transport process. By incorporating this new nucleobase into DNA, we demonstrated a protocol for real DNA nano-wire that is far superior to natural DNA. We also demonstrated that the selectivity for the interaction of Mn(II) ion with guanine N7 in G runs is a HOMO-controlled process, and as a consequence, the selectivity for G-metal ion interactions obtained by 15N-NMR studies would directly reflect the HOMO distribution of G-containing sequences in B-DNA. PMID:12903077
2002-01-01
British Library Electronic Table of Contents (United Kingdom)
We discuss the feasibility of a hierarchical protocol whereby the description and prediction of adsorbed fluids in confined systems at the mesoscopic scale is achieved by use of interface potentials that are obtained from raw molecular simulation data. Starting from a microscopic description of a fluid?s interface on a flat substrate, we attempt to extract the minimum information that is required in order to predict the behavior of that fluid at larger length scales from coarse grained surface Hamiltonians. A critical assessment of this procedure hinges on controversial aspects of wetting behavior and more generally on the meaning of metastability and instability of thermodynamic systems.
2011-01-01
Climate change - the contribution from air travel
International Nuclear Information System (INIS)
The paper discusses the Intergovernment Panel on Climate Change (IPCC) report on Aviation and the Global Atmosphere (published in 1999). It was considered necessary to treat air transport on its own since aircraft are unique in delivering emissions into the upper atmosphere rather than at ground level. The study was commissioned at the request of the International Civil Aviation Organisation and the Montreal Protocol. More than 300 experts contributed and the report has quantified the effect of aviation on the atmosphere on a world wide basis and highlighted areas where improved data are required. (UK)
2000-04-01
British Library Electronic Table of Contents (United Kingdom)
Abstract The white sea bream, Diplodus sargus (Teleostei, Sparidae), is a species with a high commercial importance in Mediterranean aquaculture. There is currently little information available about the genetic characteristics of cultured populations. In this survey, we have developed eight polymorphic microsatellites for the white sea bream using an enriched genome library protocol. All of them were polymorphic in the 67 individuals tested, 32 of which were wild specimens, and 35 were individuals from a captive F1 broodstock. These markers can potentially be useful tools for use in population genetic studies.
2008-01-01
Carbon Trading with Imperfectly Observable Emissions
Energy Technology Data Exchange (ETDEWEB)
The Kyoto Protocol foresees emission trading but does not yet specify verification of (uncertain) emissions. This paper analyses a setting in which parties can meet their emission targets by reducing emissions, by investing in monitoring (reducing uncertainty of emissions) or by (bilaterally) trading permits. We derive the optimality conditions and carry out various numerical simulations. Our applications suggest that including uncertainty could increase compliance costs for the USA, Japan and the European Union. Central Europe and the Former Soviet Union might be able to gain from trading due to higher permit prices. Emissions trading could also lower aggregate uncertainty on emissions.
2003-06-01
A practical scheme for error control using feedback
We describe a scheme for quantum error correction that employs feedback and weak measurement rather than the standard tools of projective measurement and fast controlled unitary gates. The advantage of this scheme over previous protocols (for example Ahn et. al, PRA, 65, 042301 (2001)), is that it requires little side processing while remaining robust to measurement inefficiency, and is therefore considerably more practical. We evaluate the performance of our scheme by simulating the correction of bit-flips. We also consider implementation in a solid-state quantum computation architecture and estimate the maximal error rate which could be corrected with current technology.
2004-01-01
International Nuclear Information System (INIS)
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that may be used for diagnostics. To provide shielding for minimizing the risk of exposure to personnel and ...
Dosimetry for Total Skin Electron Beam Therapy in Skin Cancer
International Nuclear Information System (INIS)
Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeV electron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. During treatment, the patient was placed in six different positions due to be homogeneous dose distribution for whole skin around ...
1992-06-01
Energy Technology Data Exchange (ETDEWEB)
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also conveniently tabulated for {sup 32}P, {sup 35}S, {sup 86}Rb, {sup ...
1994-02-01
One-step purification of Taq DNA polymerase using nucleotide-mimetic affinity chromatography.
The thermostable Thermus aquaticus DNA polymerase (Taq Pol) has been the key factor in transforming the initial PCR method into one with huge impact in molecular biology and biotechnology. Therefore, the development of effective affinity adsorbents for the purification of Taq Pol, as well as other DNA polymerases, attracts the attention of the enzyme manufacturers and the research laboratories. In this report we describe a simple protocol for the purification of Taq Pol from E. coli lysates, leading to enzymes of high specific activity and purity. The protocol is based on a single affinity chromatography step, featuring an immobilized ligand selected from a structure-biased combinatorial library of dNTP-mimetic synthetic ligands. The ligand library was screened for its ability to bind and purify Taq Pol from E. coli lysates. One immobilized ligand (mABSGu) of the general formula X-Trz-Y, bearing 9-aminoethylguanine (AEGu) and aniline-2-sulfonic ...
2007-01-01
Long-term results in 144 localized Ewing's sarcoma patients treated with combined therapy
International Nuclear Information System (INIS)
The results of 144 previously untreated cases of primary Ewing's sarcoma of bone are reported with a minimum follow-up of 5 years. This series was treated between 1972 and 1982 at Istituto Ortopedico Rizzoli with a combined therapy. The local control of the disease consisted of amputation (ten cases), resection followed by radiation therapy (35-45 Gy) (48 cases) and radiation therapy alone (40-60 Gy) (86 cases). Adjuvant chemotherapy, rigorously standardized, was performed according two different protocols: the first (85 cases treated in the period 1972-1978) consisted of vincristine (VCR) Adriamycin (doxorubicin) (ADM), and cyclophosphamide (EDX); the second (59 cases treated in the period 1979-1982) of VCR, ADM, EDX and dactinomycin (DACT). At a follow-up of 5 to 16 years (median, 9), 59 patients (41%) are continuously disease-free (CDF), 81 (56%) developed metastatic disease and/or local recurrence, and four (3%) had a second malignancy. Three factors seem to be ...
Intensive combined modality therapy including low-dose TBI in high-risk Ewing's sarcoma patients
International Nuclear Information System (INIS)
Twenty-four high-risk Ewing's sarcoma patients were treated on an intensive combined modality protocol including low-dose fractionated total body irradiaiton (TBI) and autologous bone marrow infusion (ABMI). Twenty patients (83%) achieved a complete clinical response to the primary and/or metastatic sites following induction therapy. The median disease-free interval was 18 months, and nine patients remain disease-free with a follow-up of 22 to 72 months. Local failure as a manifestation of initial relapse occurred in only three patients (15%), each having synchronous distant failure. Eight patients failed initially with only distant metastases, usually within 1-2 years following a complete clinical response. Two patterns of granulocyte recovery following consolidative therapy (including TBI and ABMI) were recognized. The time to platelet recovery was different for the groups with early and late granulocyte recovery. Patients with late recovery did not tolerate ...
Energy Technology Data Exchange (ETDEWEB)
Excitation functions for {sup 201}Pb, {sup 202m}Pb, {sup 203}Pb and {sup 204m}Pb radionuclides which are formed via proton induced reactions with natural thallium target have been measured from their respective threshold (E{sub thr}) to 27.5 MeV using activation technique. Natural copper foils were used to monitor the cyclotron beam. The integral yields (MBq/{mu}A h) of the produced radionuclides were calculated from the measured excitation functions. The optimum proton energy range for the production of {sup 203}Pb with low amount of impurities is (16-10 MeV) after 5 h of EOB. The experimental cross-sections for {sup nat}Tl(p,xn) reactions were compared with the cross-sections recommended by the IAEA and with earlier published data when it was possible. (orig.)
2007-07-01
U.S. Department of Energy`s International Safeguards Program
Energy Technology Data Exchange (ETDEWEB)
Since 1978 the United States Department of Energy`s (DOE) International Safeguards Program has conducted policy analysis, strategies and technology development, international cooperation and training to support the formulation and implementation of international safeguards. The end of the Gulf War (1991), the end of the Cold War (1992), and the trend towards regionalization of safeguards has led to increased US and international attention to the threat of nuclear weapons proliferation and the need for significantly greater support to nonproliferation policy making and implementation activities. As a result, DOE`s International Safeguards Program has undergone substantial growth and has continued to focus its resources on the priority issues which are part of today`s and tomorrow`s world. In order to effectively and efficiently conduct and manage these activities the International Safeguards Program has developed and continues to refine and implement a strategic plan. This plan provides ...
1993-12-31
Study on upgrading of oil palm wastes to animal feeds by radiation and fermentation processing
International Nuclear Information System (INIS)
Upgrading of oil palm empty fruit bunch (EFB), which is a main by-product of palm oil industry, to animal feeds by radiation pasteurization and fermentation was investigated for recycling the agro-resources and reducing the environmental pollution. The following results were obtained: 1) The necessary dose for pasteurization of EFB contaminated by various microorganisms including aflatoxin producing fungi was determined as 10 kGy. The chemical and biological properties of EFB were changed little by irradiation up to 50 kGy. 2) In the fermentation process, Pleurotus sajor-caju was selected as the most effective fungi and the optimum condition for fermentation was clarified. The process of fermentation in suspension was also established for the liquid seed preparation. 3) The digestibility and nutritional value of fermented products were evaluated as ruminant animal feeds and the mushroom can be produced as by-product. 4) The pilot plant named Sterifeed was built at MINT and a large ...
2002-10-15
Spent fuel management: Current status and prospects 1993
International Nuclear Information System (INIS)
Spent fuel management has always been one of the most important stages in the nuclear fuel cycle and it is still one of the most vital problems common to all countries with nuclear reactors. It begins with the discharge of spent fuel from a power or a research reactor and ends with its ultimate disposition, either by direct disposal or by reprocessing of the spent fuel. Two options exist at present - an open, once-through cycle with direct disposal of the spent fuel and a closed cycle with reprocessing of the spent fuel and recycling of plutonium and uranium in new mixed oxide fuels. The selection of a spent fuel strategy is a complex procedure in which many factors have to be weighed, including political, economic and safeguards issues as well as protection of the environment. Continuous attention is being given by the IAEA to the collection, analysis and exchange of information on spent fuel management. Its role in this area is to provide a forum for the exchange ...
International Nuclear Information System (INIS)
The present document represents an attempt to summarize the most important features of the different forms of ED-XFR as applied to the analysis of airborne particulate matter. It is intended to serve as a set of guidelines for use by participants in the IAEA's own programmes, and other scientists, who are not yet fully experienced in the application of ED-XRF to airborne particulate samples, and who wish either to make a start on using this technique or to improve their existing procedures. The methodologies for sampling described in this document are of rather general applicability. Emphasis is also placed on the sources of errors affecting the sampling of airborne particulate matter. The analytical part of the document describes the different forms of ED-XRF and their potential applications. Spectrum evaluation, a key step in X-ray spectrometry, is covered in depth, including discussion on several calibration and peak fitting techniques and computer programs ...
1986-06-25
Planning of Medium- and Long-Term Strategy for the Safeguards Technology Development
International Nuclear Information System (INIS)
In Rep. of Korea, active safeguards technology development suitable to phase of a nuclear advanced country is necessary because of below reasons. First reasons are '6th ranked position in the nuclear energy generation all over the world', 'continuously increased outcomes in the various nuclear fields such as research or patent', 'strengthened intention of the new government for nuclear industries', and 'weakness of the R and D foundation related to the safeguards technology'. Second reasons are optimization necessity of the effectiveness and efficiency of safeguards according to enlargement of the SSAC (State Systems of Accounting for and Control) role. The reason of the enlargement of the SSAC is IAEA IS (Integrated Safeguards) application for Korea. Third reasons are necessity for the systematic national development plan considering the Korea R and D level and the degree of the difficulty of technology. This is to say, there is necessity of the system ...
2009-05-01
International symposium on nuclear security. Book of extended synopses
International Nuclear Information System (INIS)
The International Symposium on Nuclear Security took place within a context of international acknowledgement that the threat of nuclear terrorism required dedicated action by the international community, States, industry and others. The Symposium dealt with those issues involved in protecting nuclear and other radioactive material from criminals. It also took place against a backdrop of renewed interest in nuclear technology: increased use of nuclear power, and increased use of radioactive isotopes in medicine and in industry. These are welcome developments, since nuclear energy and technology can indeed contribute to the technological and economic welfare of many countries, without compromising public health or the environment. In this context, security measures should not impede State programmes for peaceful use of nuclear technology. The symposium dealt with (1) the threat of nuclear terrorism and of other nuclear-related criminal acts; (2) international response and cooperation; ...
2003-11-05
IAEA RESEARCH CONTRACTS SECOND ANNUAL REPORT. Technical Reports Series No. 9
Summaries are presented for those research contracts which expired between December 31, 1960 and December 31, 1981. Topics covered include: factors controlling distribution of fission products in biosphere, non-destructive methods of evaluating the U/sup 235/ and Pu content of irradiated fuel elements, studies of contamination in local marine resources, tracer studies of anemia, non-destructive analysis of irradiated fuel elements using a flux integrating monitor, mechanism of proteolysis of I/sup 131/-labeled fibrinogen, radiosensitivity of spermatogonia of Drosophila melel elements by gamma scanning, uptake and loss of radioactive material by marine bacteria, factors which influence the movement of radioactive strontium from soils to plants, biological concentration of fission products in mollusks from water, decay scheme of Tl/sup 210/, calcium balance in metabolic bone disease, development of radioactive drugs with special reference to tritiated drugs as ...
1962-01-01
Enhancing nutrient management through use of isotope techniques
International Nuclear Information System (INIS)
Enhanced nutrient cycling basically involves close interaction between inorganic and organic sources of nutrients. Contrasting scenarios of nutrient cycling are found under intensive cropping production systems in most industrialized countries and traditional production systems predominant in many developing countries, where there is a net mining of soil nutrients due to crop harvest removal and erosion. Therefore, to enhance nutrient management in marginal tropical soils it is necessary to maximize the efficiency of nutrient uptake from various inorganic and organic sources with minimal environmental impact. It is postulated that one of the main approaches will be the identification and/or selection of plant genotypes for enhanced nutrient acquisition, in particular at low levels of soil available nutrients. In this context, use of various isotope techniques in examining root activity/distribution pattern and plant nutrient uptake is examined. On the other hand, the need for ...
1994-10-17
Development of new radiopharmaceuticals
International Nuclear Information System (INIS)
The possibilities to design and prepare better and more organ-specific radiopharmaceuticals for diagnostic nuclear medicine has increased dramatically in the recent past with a deeper understanding of the relationships between chemical structure and biological activity. Whereas most of the research is performed in well-funded laboratories of industrialized countries, there are several developing countries with adequate resources and expertise as to undertake fruitful research in the field of radiopharmacy. With the aim of promoting advanced research in radiopharmacy by developing new radiodiagnostics agents, in particular, hepatobiliary imaging agents labelled with "9"9"mTc, and to facilitate exchange of information, the IAEA has established in 1983 the present Research Co-ordination Programme (CRP) with a duration of five years. The report includes detailed results obtained by all participants as well as novel preparation procedures for some of the newest and more ...
1988-09-12
Core reactor calculation using the adaptive remeshing with a current error estimator
International Nuclear Information System (INIS)
With the objective to improve the reactor physics calculation on a 2D and 3D nuclear reactor via the Diffusion Equation, an adaptive automatic finite element remeshing method, based on the elementary area (2D) or volume (3D) constraints, has been developed. The adaptive remeshing technique, guided by a posteriori error estimator, makes use of two external mesh generator programs: Triangle and TetGen. The use of these free external finite element mesh generators and an adaptive remeshing technique based on the current field continuity show that they are powerful tools to improve the neutron flux distribution calculation and by consequence the power solution of the reactor core even though they have a minor influence on the critical coefficient of the calculated reactor core examples. Two numerical examples are presented: the 2D IAEA reactor core numerical benchmark and the 3D model of the Argonauta research reactor, built in Brasil. (author)
Conceptual Framework of Economic Evaluation on SMRs
International Nuclear Information System (INIS)
Korea Atomic Energy Research Institute(KAERI) launched a project to develop an integral reactor in 1996. The reactor called as System Integrated Modular Advanced Reactor(SMART) which is a kind of small modular reactors (SMRs). Since the early 1990s, there has been renewed interest in the development and application of small and medium sized integral reactors. 2009 assessment by the IAEA under its Innovative Nuclear Power Reactor and Fuel Cycle (INPRO) program concluded that there could be 96 SMRs in operation around the world by 2030 in its 'high' case, and 43 units in the 'low' case, none of them in the USA. The reason of the increased demand mostly comes from the fact that SMRs are thought to be more suitable for developing countries with small electrical grid capacity, insufficient infrastructure and limited investment capability than developed ones. However, it has disadvantage in the point of scale of economy. So, it should be compared the amount of this ...
2010-10-01
CFD Analysis of a Dry Storage System for MACSTOR/KN-400
International Nuclear Information System (INIS)
There are four nuclear power plants in operation at Wolsong and, annually, more than 5,000 assemblies of spent nuclear fuels are released from each plant. Thus the concrete silo type dry storage system was constructed from '90. However, after 2006, another dry storage facility is required to accept the all amount of spent nuclear fuels from the plants. Instead of the concrete silo type, MACSTOR/KN-400 was developed to store the CANDU spent nuclear fuel more densely. In this study, computational fluid dynamics (CFD) analysis of the MACSTOR/KN-400 model was performed to confirm the thermal integrity of the facility, especially for the concrete structure, using the commercial CFD code, FLUENT. The MACSTOR/KN-400 which has Thermal Insulation Panel (TIP) and IAEA Re-verification Pipe (RVP) was modeled and analyzed in the view point of the thermal integrity of the concrete structure.
2007-10-01
CANDU licensing in Korea : status review and future requirements
International Nuclear Information System (INIS)
The licensing status and procedures, regulatory framework, and current safety issues of CANDU type reactors, Wolsong units 2, 3 and 4 are examined. Licensing difficulties and lessons learned during the safety review of Wolsong 2, 3 and 4 and future requirements are also summarized. The review was conducted, not only to confirm the design adequacy with respect to the domestic atomic laws and regulatory requirements of the vendor country, Canada, but also to reflect into the design the lessons learned from the regulatory experiences of operating Wolsong I to enhance the safety as high as practically possible. Safety issues observed during the licensing review, such as containment integrity, fuel channel integrity, etc., are summarized. Several efforts have been conducted to harmonize the Canadian regulations with the Korean ones by establishing domestic regulatory positions and guidelines. For example, the utility was requested to produce the CANDU safety analysis report in a standard ...
1998-05-03
CANDU 9 - the CANDU product to meet customer and regulator requirements now and in the future
Energy Technology Data Exchange (ETDEWEB)
CANDU reactors developed under Canadian licensing regulations that placed the primary responsibility for safety on the licensee. The Atomic Energy Control Board (AECB), Canada's nuclear regulatory agency, state in their regulations what is expected in terms of safety performance so that designers are free to propose the best means of meeting this performance. This goal-oriented approach, besides encouraging innovation, allowed CANDU to be licensed in other jurisdictions. The latest design - the large, single unit, CANDU 9 - explicitly incorporates licensability in Canada through a formal AECB review of the design; lessons learned from licensing CANDU 6 in Asian countries, particularly with Wolsong 2, 3 and 4 in Korea, and more recently with Qinshan in China; utility requirements for modem evolutionary plants; and emerging international standards for safety, sponsored or issued by the IAEA. By combining the assurance of acceptability in Canada with ...
1998-07-01
CANDU 9 - the CANDU product to meet customer and regulator requirements now and in the future
International Nuclear Information System (INIS)
CANDU reactors developed under Canadian licensing regulations that placed the primary responsibility for safety on the licensee. The Atomic Energy Control Board (AECB), Canada's nuclear regulatory agency, state in their regulations what is expected in terms of safety performance so that designers are free to propose the best means of meeting this performance. This goal-oriented approach, besides encouraging innovation, allowed CANDU to be licensed in other jurisdictions. The latest design - the large, single unit, CANDU 9 - explicitly incorporates licensability in Canada through a formal AECB review of the design; lessons learned from licensing CANDU 6 in Asian countries, particularly with Wolsong 2, 3 and 4 in Korea, and more recently with Qinshan in China; utility requirements for modem evolutionary plants; and emerging international standards for safety, sponsored or issued by the IAEA. By combining the assurance of acceptability in Canada with compliance with ...
1998-05-03
Accident impact of a spent fuel dry storage package: Analytical/experimental comparison
Energy Technology Data Exchange (ETDEWEB)
Packages used for the storage and transportation of radioactive spent fuel must demonstrate the ability to withstand severe impact scenarios such as those established by the Atomic Energy Control Board (AECB) in Canada and the International Atomic Energy Agency (IAEA). One such package is the Dry Storage Container (DSC) for transporting and storing used fuel. The DSC model is comprised of several interactive components with materials such as high density concrete and polyurethane foam. To accurately model these materials, experimental studies were performed in order to provide material properties for the in-house finite element analysis code used. Structural assessments of the package design subject to postulated impact scenarios included a 9 meter center of gravity over corner drop, a 1 meter pin drop over the welded lid closure and a 1 meter center of gravity over lid pin drop. Simulations were carried out using full scale analytical models with validation by a ...
1996-12-31
Safe ageing management of nuclear power plants: An European synthesis
International Nuclear Information System (INIS)
Ageing of nuclear power plants means evolution of material or equipment properties on one side, and evolution of personnel skill and procedure adequacy on the other side, both of which, after a certain time, may not be compatible with the required safety provisions, or with an economic operation of the plant. Repair or replacement of components, as well as change in service conditions for a better compatibility with component reduced capabilities can be used to mitigate ageing effects. The paper summarises the results of a study conducted in this field with the support of the European Commission. It presents: the synthesis of the work done under international auspices, and in the European context; the comparison of ageing management approaches used in several European countries with international recommendations; the summary of the various potential phenomena and their governing parameters, the methods of in-service ageing identification and possible mitigation methods; illustrative ...
2002-11-04
The response of some TL albedo neutron dosimeters
International Nuclear Information System (INIS)
As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1 MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For neutron energies below 0.5 MeV its response varies roughly as the cosine of the angle of incidence but is more complex at higher energies. (author).
The integral experiment on beryllium with D-T neutrons for verification of tritium breeding
Energy Technology Data Exchange (ETDEWEB)
A clean benchmark experiment on beryllium was performed with D-T neutrons at the FNS facility of the Japan Atomic Energy Agency. The main objective was to verify the integral data related to the tritium production on lithium isotopes. Tritium production rates, as well as activation reaction rates were measured inside the beryllium assembly that was shaped as a pseudo-cylindrical slab with an area-equivalent diameter of 628 mm and a thickness of 355 mm. Experimental results were analyzed with a three-dimensional Monte Carlo transport code MCNP-4C and FENDL/MC-2.0, JENDL-3.2/3.3 neutron transport libraries. Evaluation of reaction rates was based on the cross section data taken from the JENDL Dosimetry File and ENDF B-VI data libraries. Analysis shows that all calculation combinations (transport and activation cross section libraries) used for evaluation of reaction rates give data that is agreeable with measured values within 10%.
2007-01-15
TLD array for precise dose measurements in stereotactic radiation techniques
International Nuclear Information System (INIS)
We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be ...
1996-12-01
Spectral energy effects in ESR bone dosimetry: photons and electrons
International Nuclear Information System (INIS)
The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for human tooth enamel and synthetic hydroxyapatite. An explanation for this difference is offered. For electron beam irradiations, the ESR signal is ...
Role of accelerator mass spectrometry in biological dosimetry
International Nuclear Information System (INIS)
Understanding risks from exposures to carcinogens and other chemicals depends upon measurement of their dose to target tissues and their reactivity with critical macromolecules. The authors have used AMS detection of radio-isotopes to assess doses and reactivities at low, environmentally relevant doses. Several biomedical investigations show the effectiveness of quantification of biologically important events at extremely high sensitivity with AMS. Specifically, they have measured the addition of environmental carcinogens such as 2-amino-3,8-dimethylimidazo[4,5-f]-quinoaxaline (MelQx), a chemical found in cooked food, to DNA at concentrations relevant to human exposure. Other low level detection problems in biology, such as immunoassay assessment of small environmental chemicals, is being developed with attomole sensitivity. AMS also aids the assessment of genotoxic risks from chemicals by quantifying the binding of labeled chemicals to DNA. The very toxic and potent carcinogen, ...
1992-04-05
Radiological concepts in radiotherapy
International Nuclear Information System (INIS)
The atomic explosions in Hiroshima and Nagasaki made the name radiation itself become a nightmare. Notwithstanding this, radiation continued to serve the mankind specially in diagnosis of several human diseases and in the treatment of intractable malignancies. With their latest research tools biologists have now shown a significant shift in the earlier paradigm; even the concept that radiation initiates cancer appears to be no longer tenable. On the contrary, selective radiation doses inhibit growth of cancer cells and radiation in combination with many chemotherapeutic drugs, radiosensitizing chemicals and/or hyperthermia, is emerging as a new modality for cancer treatment which offers high therapeutic advantages. In addition, the deleterious effects of radiation can now be strategically counter poised by the use of many drugs and chemicals. This has been possible by the newer insights gained in the mechanism of biological effects of radiation. The fate of radiation-induced free ...
Quantitative assessment of cancer risk from exposure to diesel engine emissions
Energy Technology Data Exchange (ETDEWEB)
Quantitative estimates of lung cancer risk from exposure to diesel engine emissions were developed using data from three chronic bioassays with Fischer 344 rats. Human target organ dose was estimated with the aid of a comprehensive dosimetry model. This model accounted for rat-human differences in deposition efficiency, normal particle clearance rates, transport of particles to lung-associated lymph nodes, respiration rates, and lung surface area, as well as high-dose inhibition of particle clearance. Recent evidence indicates that the inert carbon core of the diesel particulate matter is likely to be the primary source of carcinogenicity. The epithelial tissue lining the alveoli and lower airways is the primary target site for induction of lung tumors. Dose was therefore based upon the concentration of carbon particulate matter per unit lung surface area. Unit risk estimates were developed using either a time-to-tumor or a linearized multistage model. The unit ...
1993-02-01
Preliminary study of the application of natural olivine in Cenozoic dating
Energy Technology Data Exchange (ETDEWEB)
The study investigated the luminescence behaviour of natural olivine to discuss the potential for Cenozoic (quaternary) dating. The UV-blue thermoluminescence (TL) glow curves of irradiated olivines have a resolved peak at 190 deg. C and other peaks at higher temperature at lower dose levels, and broad signals around 275-310 and 375-400 deg. C at higher dose levels. The UV-blue TL increases with additional laboratory dose to {approx}1.6kGy within a plateau temperature region, suggesting the possibility of dosimetry and Cenozoic dating. Both infrared stimulated luminescence (IRSL) and blue light stimulated luminescence (BLSL) were detected from laboratory-irradiated olivines although the BLSL was weaker than the IRSL. Furthermore, post-BL IRSL was detected but post-IR BLSL was not observed. Therefore, IR stimulation is recommended for optically stimulated luminescence measurements with natural olivine. The growth of the IRSL signal component with doses less than ...
2006-08-15
Physics of electron beam therapy
International Nuclear Information System (INIS)
A book has been written to introduce the physical aspects of the radiotherapy electron beam by presenting a summary of the developments in this field. The first chapter is a brief introduction to the technology of medical accelerators with emphasis on the electron beam production facilities. Chapter 2 describes the interaction processes at the atomic level once the electron beam enters the medium. Chapter 3 is concerned with the various properties of the electron beam purely from the clinical point of view. The electron beam algorithms and models for distribution calculations are covered in Chapter 4 with inclusion of age diffusion and multiple scattering approaches. The factors affecting the beam distribution in a patient, with inhomogeneities, surface irregularities, backscattering etc. are discussed in Chapter 5. The last two chapters are devoted to electron beam dosimetry including various dosimetric methods, specification and measurement of beam energy, ...
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the evaluation of biodistribution and radiation dosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)
2005-10-15
International Nuclear Information System (INIS)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...
International Nuclear Information System (INIS)
Processing of food with ionizing radiation is a method suitable to enhance shelf-life and hygienic quality. Up to a dose of 10 kGy the method is considered wholesome. In many countries the practical use of food irradiation is increasing, however, in the Federal Republic of Germany the process is strictly forbidden. Applications and methods for radiation processing of food are compiled, limits and prospects are explained, and advantages and disadvantages are compared with traditional methods. Identification of irradiated foods and dosimetry and process control for radiation processing of food are areas where further research is needed. Continuous processing of particulate foods in bulk is an application where electron accelerators might be profitable. Beam parameters and velocity distribution of food particles in the treatment area can be matched for an effective result. Thus, dose distribution can be adjusted for homogeneous treatment and at the same time radiation ...
International Nuclear Information System (INIS)
Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral hip prostheses. The ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as Balance-of-Plant (BOP) ...
1999-04-02
Extremely low frequency electric and magnetic fields and cancer: A literature review
Energy Technology Data Exchange (ETDEWEB)
Epidemiologic studies suggest a weak link between occupational or residential exposure to extremely low frequency electromagnetic fields and cancer, especially tumors of the central nervous and hematopoietic systems. This report discusses these studies with reference to basic research on ELF EMF bioeffects relevant to cancer-promoting mechanisms. Many of the studies suggest a possible interaction of ELF EMF with the immune system, endocrine system, or growth-regulatory signals and morphogenic movements that involve calcium flux through cell membranes. Many bioeffects have been reported only with certain specific combinations of frequency, amplitude, and orientation of the EMF signal with respect to the geomagnetic field. The possibility of signal-specific effects raises a complication in dosimetry for both epidemiologic and experimental studies since ELF EMF effects may not be directly related to field strength. The report concludes with a discussion of design ...
1989-12-01
Energy Technology Data Exchange (ETDEWEB)
The study compares the doses absorbed by the dentomaxillary area in spiral CT and panoramic examinations. The dose measurements demonstrate that patients receive smaller doses with panoramic radiography than with spiral CT with Dentascan. After following for some variations from instrumental differences, they are in substantial agreement with literature data. Further investigations are needed considering the radiobiological risk related to the growing spread of Dentascan examinations. [Italian] Questo lavoro intende confrontare le dosi assorbite nel distretto dento-mascellare, con le due principali tecniche utilizzate in questo campo: TC spirale e ortopantomografia. Emerge come l'esame panoramico delle arcate dentarie eseguito con l'ortopantomografo comporti la'ssorbimento di dosi inferiori rispetto a quelle dell'esame TC spirale con programma Dentascan. Questi dati, pur essendo soggetti a variabilita' dovuta alla strumentazione utilizzata, ...
1999-05-01
Monte Carlo calculations using the codes PENELOPE and GEANT4 have been performed to characterize the dosimetric parameters of the new 20 mm long catheter based $^{32}$P beta source manufactured by Guidant Corporation. The dose distribution along the transverse axis and the two dimensional dose rate table have been calculated. Also, the dose rate at the reference point, the radial dose function and the anisotropy function were evaluated according to the adapted TG-60 formalism for cylindrical sources. PENELOPE and GEANT4 codes were first verified against previous results corresponding to the old 27 mm Guidant $^{32}$P beta source. The dose rate at the reference point for the unsheathed 27 mm source in water was calculated to be $0.215 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, for PENELOPE, and $0.2312 \\pm 0.0008$ cGy s$^{-1}$ mCi$^{-1}$, for GEANT4. For the unsheathed 20 mm source these values were $0.2908 \\pm 0.0009$ cGy s$^{-1}$ mCi$^{-1}$ and $0.311 \\pm 0.001$ cGy s$^{-1}$ mCi$^{-1}$, ...
2003-01-01
International Nuclear Information System (INIS)
A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray contamination is less than 4% for any applicator/electron energy combination. A system for irregular field blocking and TLD verification ...
Development of real time personal neutron dosimeter with two silicon detectors
Energy Technology Data Exchange (ETDEWEB)
The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron fields around a few accelerator facilities. (author)
1997-07-01
Development of radiological emergency preparedness and biological dosimetry technology
Energy Technology Data Exchange (ETDEWEB)
Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for the assessment of health effect by radiation and toxic agents, ...
1999-04-01
DOE personnel neutron dosimetry evaluation and upgrade program
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent System is being developed to provide guidance in ...
1988-10-01
Computed tomography of the orbit
Energy Technology Data Exchange (ETDEWEB)
In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and arteriography as major imaging techniques in orbital ...
1981-01-01
Energy Technology Data Exchange (ETDEWEB)
Radon exposure assessment in case-control studies on radon and lung cancer is generally based on contemporary radon concentration measurements, which can be affected by significant changes in the building structures or in living habits. Another method to estimate the radon exposure of the subjects is the recently developed retrospective dosimetry technique based on the {sup 210}Po surface activity from glass objects. In order to compare the results obtained by the two methods, a study has been carried out in a sample of 26 dwellings in Rome, with radon concentration values ranging from 28 to 623 Bq m{sup -3}. Retrospective detectors based on CR-39 and LR 115 were exposed on 50 glass objects in bedrooms and living rooms. The correlation factor between the two sets of data, after removing six extreme values, is 0.67, which is similar to results obtained in other validation studies of similar sample size. The correlation increases to 0.83 if the 21 objects exposed in ...
2003-06-01
Characterization of Radiation Instruments at the Summit of Mt. Fuji
International Nuclear Information System (INIS)
The opportunity of exposure to high-energy radiation up to GeV is increasing as in civilian aircrafts and at particle accelerators. The transport of such energetic particle is still difficult to describe precisely and thus verification by measurement using a well characterized instrument is indispensable for reliable dosimetry. However, no reference calibration field has been established for the high-energy range. We thus propose to use a facility at the summit of Mt. Fuji (3776 m in altitude; N35.36o, E138.73o), the highest place in Japan, for characterization of radiation instruments that are possibly used in high-energy radiation fields. For demonstration of the effectiveness, two moderator-type neutron monitors (NCN1 and WENDI-II) having different energy response functions were employed for cosmic-ray neutron measurements in the summer of 2009. In comparison with numerically simulated values, it was found that the extended energy neutron monitor (WENDI-II) has ...
2010-12-01
Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams
International Nuclear Information System (INIS)
Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of tissueequivalent ...
2010-10-01
APMP/TCRI key comparison report of measurement of air kerma for medium-energy x-rays (APMP.RI(I)-K3)
Energy Technology Data Exchange (ETDEWEB)
The APMP/TCRI Dosimetry Working Group performed the APMP.RI(I)-K3 key comparison of measurement of air kerma for medium-energy x-rays (100 kV to 250 kV) between 2000 and 2003. In total, 11 institutes took part in the comparison, among which 8 were APMP member laboratories. Two commercial cavity ionization chambers were used as transfer instruments and circulated among the participants. All the participants established the 100 kV, 135 kV, 180 kV and 250 kV x-ray beam qualities equivalent to those of the BIPM. The results showed that the maximum difference between the participants and the BIPM in the medium-energy x-ray range, evaluated using the comparison data of the linking laboratories ARPANSA and PTB, is less than 1.4%. The degrees of equivalence between the participants are presented and this comparison confirms the calibration capabilities of the participating laboratories. (authors)
2008-10-15
A water calorimeter for high energy x-rays and electrons
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeV electrons agreed, within the measurement uncertainties of approximately 1.5% (95% c.l.), with those ...
2000-01-01
The optically stimulated luminescent (OSL) radiation dosimeter technically surveys a wide dynamic measurement range and a high sensitivity. Optical fiber dosimeters provide capability for remote monitoring of the radiation in the locations which are difficult-to-access and hazardous. In addition, optical fiber dosimeters are immune to electrical and radio-frequency interference. In this paper, a novel remote optical fiber radiation dosimeter is described. The optical fiber dosimeter takes advantage of the charge trapping materials CaS:Ce, Sm that exhibit OSL. The measuring range of the dosimeter is from 0.1 to 100 Gy. The equipment is relatively simple and small in size, and has low power consumption. This device is suitable for measuring the space radiation dose and also can be used in high radiation dose condition and other dangerous radiation occasions. Supported by National Natural Science Foundation of China (10475112), Western Light Foundation of Chinese Academy of Sciences of ...
2008-05-01
International Nuclear Information System (INIS)
Operations at the Savannah River Site (SRS) result in releases of small amounts of radioactive materials to the atmosphere and to the Savannah River. For regulatory compliance purposes, potential offsite radiological doses are estimated annually using computer models that follow U.S. Nuclear Regulatory Commission (NRC) Regulatory Guides. Within the regulatory guides, default values are provided for many of the dose model parameters but the use of site-specific values by the applicant is encouraged. A detailed survey of land and water use parameters was conducted in 1991 and is being updated here. These parameters include local characteristics of meat, milk and vegetable production; river recreational activities; and meat, milk and vegetable consumption rates as well as other human usage parameters required in the SRS dosimetry models. In addition, the preferred elemental bioaccumulation factors and transfer factors to be used in human health exposure calculations ...
Energy Technology Data Exchange (ETDEWEB)
The focus of this study is on the preparatory detection of uncertain net greenhouse gas (GHG) emission changes (also termed emission signals) under the Kyoto Protocol. The crucial question to be addressed is: How well do we need to know net emissions if we want to detect a specified emission signal after a given time? No restrictions exist as to what concerns the net emitter, which may be any GHG source or sink. Annex I countries are chosen as net emitters, simply for reasons of data availability and because of the excellent possibility of comparing net emitters (inter-country comparison). The countries' emissions - in an increasing number of cases even their uncertainties - are available permitting the application of preparatory signal detection techniques, which are suited to address the aforementioned question. We currently discuss four hierarchically-ordered detection concepts to assess emission signals in a preparatory manner, that is, at two ...
2004-06-14
Computed tomography whole body imaging in multi-trauma: 7 years experience
International Nuclear Information System (INIS)
AIM: To assess the impact of the introduction of a computed tomography (CT) imaging protocol for multi-trauma patients on the workload, overall diagnostic yield, and effect on detection of cervical spine injury and pneumothorax. METHOD: Between February 1997 and April 2004, all patients presenting acutely to the Emergency Department (ED) with haemodynamically stable trauma (Abbreviated Injury Scale 3 or more) involving more than two body systems were imaged with a comprehensive pre-set helical CT protocol (including non-contrast head, cervical spine: cranio-cervical and cervico-thoracic junctions; and oral and intravenous contrast-enhanced thoracic, abdomen and pelvis) after initial triage and a standard trauma series of radiographs (chest, lateral C-spine and pelvis). Diagnosis of cervical spine fracture and pneumothorax was noted before and after the CT protocol was carried out and findings from all studies were recorded ...
2006-04-01
Energy Technology Data Exchange (ETDEWEB)
This document describes products which the US EPA Wetlands Research Program proposes to develop during the years 1989-1994. The general protocols used to develop these products are also described. All these products are intended to address concerns about the wetlands and water quality, and are part of a larger set of products EPA is developing to deal with other aspects of wetlands. EPA's highly interrelated concerns about wetlands and water quality can be generally categorized as follows: water quality criteria to protect wetland function; ecological status of the wetland resource; and waste-assimilation limits of wetlands.
1989-04-01
Weak values under uncertain conditions
British Library Electronic Table of Contents (United Kingdom)
We analyze the average of weak values over statistical ensembles of pre- and post-selected states. The protocol of weak values, proposed by Aharonov et al. [Phys. Rev. Lett. 60 (1988) 1351], is the result of a weak measurement conditional on the outcome of a subsequent strong (projective) measurement. Weak values can be beyond the range of eigenvalues of the measured observable and, in general, can be complex numbers. We show that averaging over ensembles of pre- and post-selected states reduces the weak value within the range of eigenvalues of Formula Not Shown . We further show that the averaged result expressed in terms of pre- and post-selected density matrices, allows us to include the effect of decoherence.
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
Paget Schroetter syndrome, or effort thrombosis of the axillosubclavian venous system, is distinct from other forms of upper limb deep vein thrombosis. It occurs in younger patients and often is secondary to competitive sport, music, or strenuous occupation. If untreated, there is a higher incidence of disabling venous hypertension than was previously appreciated. Anticoagulation alone or in combination with thrombolysis leads to a high rate of rethrombosis. We have established a multidisciplinary protocol over 15?years, based on careful patient selection and a combination of lysis, decompressive surgery, and postoperative percutaneous venoplasty. During the past 10?years, a total of 232 decompression procedures have been performed. This article reviews the literature and presents the Exet...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
We present a novel preparation method for studies of in vitro reconstituted mitotic chromosomes from Xenopus laevis egg extracts. This method involves a gentle adsorption of chromosomes from the extracts using surface affinity enrichment, followed by plunge freezing, freeze-substitution and cryo-embedding before examination by EM tomography. For comparison, chromosomes were also prepared by a conventional method, which included immobilization of chromosomes in agarose and a room-temperature dehydration (embedding) protocol. Three-dimensional reconstructions showed that samples prepared with the new method have a greater interconnectivity of sub-structural features and a higher compaction ratio together with an apparently less perturbed chromatin structure than those prepared using the conventional approach. The implications of the new method for the preparation of other difficult samples and additional application possibilities are discussed.
2005-07-15
Uniform and Residue-specific {sup 15}N-labeling of Proteins on a Highly Deuterated Background
Energy Technology Data Exchange (ETDEWEB)
A general method for stable-isotope labeling of large proteins is introduced and applied for studies of the E. coli GroE chaperone proteins by solution NMR. In addition to enabling the residue-specific {sup 15}N-labeling of proteins on a highly deuterated background, it is also an efficient approach for uniform labeling. The method meets the requirements of high-level deuteration, minimal cross-labeling and high protein yield, which are crucial for NMR studies of structures with sizes above 150 kDa. The results obtained with the new protocol are compared to other strategies for protein labeling, and evaluated with regard to the influence of external factors on the resulting isotope labeling patterns. Applications with the GroE system show that these strategies are efficient tools for studies of structure, dynamics and intermolecular interactions in large supramolecular complexes, when combined with TROSY- and CRINEPT-based experimental NMR schemes.
2004-07-15
British Library Electronic Table of Contents (United Kingdom)
This review describes how a mismatch between the knowledge produced by scientists and the evidence demanded by regulators has emerged, and how society has struggled to find definitive answers to questions of safety, for an important flame retardant chemical in current use ? Deca-BDE. This has involved two key disciplines: analytical chemistry and toxicology. Within the chemistry, a lack of standardized methodologies among scientists has resulted in a persistent yet largely undeclared failure to replicate results within the discipline. Within the toxicology, the quest for innovative, curiosity-driven research by university scientists in preference to using validated standard protocols, designed to promote consistency within the risk assessment process, has prompted questions about the credi...
2011-01-01
The Successive Approximation Approach for Multi-path Utility Maximization Problem
The network utility maximization (NUM) problem for multi-path is a problem which is non-strictly convex and non-separable. Using Jensen's inequality, we approximate the NUM to a strictly convex and separable problem which can be solved efficiently by the dual decomposition method. After a series of approximations, the result of the approximation problem converges to the globally optimal solution of the original NUM. Moreover, because of the separable and dual-based natures of the proposed algorithm, we utilize the reverse engineering frameworks of the current TCPs to develop a series of multi-path TCPs which are totally compatible with current TCPs. The multi-path users using our protocols can run simultaneously with the single-path users using the current TCPs. The simulations of our Multi-path Reno on ns-2 show the compatibility and the fairness among multi-path and single-path users.
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
There are mainly two protocols in isoflavone analysis, one that involves hydrolysis prior to HPLC analysis and the other direct HPLC analysis. In this study, three different hydrolysis methods were systematically re-evaluated, and compared with direct HPLC analysis. Acidic hydrolysis (1.2-3M HCl in ethanol at 80^oC) showed a maximum conversion of ca. 92% from glucosides to aglycones in 2h; however, longer reaction caused degradation of genistein. Alkaline hydrolysis using 2M NaOH converted acetylglucosides and malonylglucosides to their respective glucosides within 10min. Glucuronidase from H. pomatia effectively converted isoflavone glucosides and acetylglucosides to aglycones. Quantification of the total isoflavones in various soy food products showed no significant difference among dire...
2011-01-01
Students' general and physics epistemological beliefs: a twofold phenomenon
British Library Electronic Table of Contents (United Kingdom)
Background: Although research on epistemological beliefs has expanded over the past two decades, there are still some issues that need to be explored, such as whether epistemological beliefs are domain general or domain specific. Purpose: One of the purposes of this research was to determine if high school students' general epistemological beliefs were different from their epistemological beliefs in the domain of physics. Sample: The research was conducted with 15 grade nine students studying in an urban all-boys school. Their average age was 16. Their previous school experiences were traditional oriented. Design and methods: A case study design with qualitative methods was used for the research. Two questionnaires were developed and used in semi-structured interview protocols two times, w...
2011-01-01
Security of mobile agents: a new concept of the integrity protection
The recent developments in the mobile technology (mobile phones, middleware) created a need for new methods of protecting the code transmitted through the network. The proposed mechanisms not only secure the compiled program, but also the data, that can be gathered during its "journey". The oldest and the simplest methods are more concentrated on integrity of the code itself and on the detection of unauthorized manipulation. Other, more advanced proposals protect not only the code but also the execution state and the collected data. The paper is divided into two parts. The first one is mostly devoted to different methods of securing the code and protecting its integrity; starting from watermarking and fingerprinting, up to methods designed specially for mobile agent systems: encrypted function, cryptographic traces, time limited black-box security, chained-MAC protocol, publicly-verifiable chained digital signatures The second part presents new concept for ...
2005-01-01
British Library Electronic Table of Contents (United Kingdom)
Introduction: Patients in underdeveloped nations have limited access to life-saving medical technology including cardiac rhythm management (CRM) devices. We evaluated alternative means to provide such technology to this patient population while assessing the safety and efficacy of such a practice. Methods: Patients in the United States with clinical indications for extraction of CRM devices were consented. Antemortem CRM devices were cleaned and sterilized following a protocol established at our institution. Surveillance in vitro cultures were performed for quality assurance. The functional status of pulse generators was tested with a pacing system analyzer to confirm at least 70% battery life. Most generators were transported, in person, to an implanting institution in Nicaragua. Recipien...
2011-01-01
Quantum secure direct communication by EPR pairs and entanglement swapping
We present a quantum secure direct communication scheme achieved by swapping quantum entanglement. In this scheme a set of ordered Einstein-Podolsky-Rosen (EPR) pairs is used as a quantum information channel for sending secret messages directly. After insuring the safety of the quantum channel, the sender Alice encodes the secret messages directly by applying a series local operations on her particle sequences according to their stipulation. Using three EPR pairs, three bits of secret classical information can be faithfully transmitted from Alice to remote Bob without revealing any information to a potential eavesdropper. By both Alice and Bob's GHZ state measurement results, Bob is able to read out the encoded secret messages directly. The protocol is completely secure if perfect quantum channel is used, because there is not a transmission of the qubits carrying the secret message between Alice and Bob in the public channel.
2004-03-01
British Library Electronic Table of Contents (United Kingdom)
Abstract Elevated temperatures resulting from climate change pose a clear threat to reef-building corals; however, the traits that might influence corals- survival and dispersal during climate change remain poorly understood. Global gene expression profiling is a powerful hypothesis-forming tool that can help elucidate these traits. Here, we applied a novel RNA-Seq protocol to study molecular responses to heat and settlement inducers in aposymbiotic larvae of the reef-building coral Acropora millepora. This analysis of a single full-sibling family revealed contrasting responses between short- (4-h) and long-term (5-day) exposures to elevated temperatures. Heat shock proteins were up-regulated only in the short-term treatment, while the long-term treatment induced the down-regulation of rib...
2011-01-01
International Nuclear Information System (INIS)
The document presents an overview on atmospheric pollution in Lebanon, with an analysis of sources of pollution, their impact on local and global environment and their control.Local causes of pollution are mainly: -Thermal power plants of electric power production which produce 75% SO_2 emission and 60% dust - Industries, especially cement industry - Land transportation which produces 70% NOX emission and 50% CO_2 A description of air pollution caused by these three sectors is revealed. Pollutants derived from fuel combustion are analyzed. It is estimated that in 2010, Co_2 emission will reach 5204450 tons, SO_2 emission will be 136470 tons, NOX emissions 96870 and dust estimated to 4130 tons. CFC consumption and measures of control according to Montreal Protocol are described. Recommendations for control of air pollution in Lebanon within a national policy are presented.
British Library Electronic Table of Contents (United Kingdom)
Abstract: The recent National Academy of Sciences report on forensic sciences states that the study of fire patterns and debris in arson fires is in need of additional work and eventual standardization. We discuss a recently introduced method that can provide predicted evaporation patterns for ignitable liquids as a function of temperature. The method is a complex fluid analysis protocol, the advanced distillation curve approach, featuring a composition explicit data channel for each distillate fraction (for qualitative, quantitative, and trace analysis), low uncertainty temperature measurements that are thermodynamic state points that can be modeled with an equation of state, consistency with a century of historical data, and an assessment of the energy content of each distillate fraction...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The author investigates whether the international law regime so far has developed any legal principles dealing with the problem of the dumping of radioactive waste in the sub-seabed, and whether any of such provisions available adequately tackle the problem in the light of the gravity of danger emanating from radioactive waste. The study covers over 30 different texts of international treaties and protocols. Points of main interest are the London Dumping Convention and the Montego Bay Convention on the Law of the Sea. The author concludes that the disposal of radioactive waste into the seabed belongs to the permissible, although not specially allowed activities within the framework of the freedom of the high seas, and therefore urgently calls for establishing an international regulatory system pertaining to the planning and accomplishment of such activities. An outline legal concept of a regulatory system is explained. (orig./HSCH).
1986-01-01
Penile rehabilitation therapy following radical prostatectomy is a much debated topic. Erectile dysfunction is still a significant contributor to postoperative morbidity following radical prostatectomy, despite meticulous nerve-sparing technique. Secondary smooth muscle changes in the penis have been identified as the underlying causes of penile atrophy, veno-occlusive dysfunction, and fibrosis. Initial observations that intracavernous injection therapies used on a regular basis postoperatively resulted in improvements in the return of spontaneous erectile function led to the development of penile rehabilitation protocols. Chronic dosing of PDE-V inhibitors is now commonly used by urologists after radical prostatectomy. Despite the current enthusiasm of penile rehabilitation therapy, current scientific evidence with clinical trials is still limited. PMID:19255627
2009-01-25
British Library Electronic Table of Contents (United Kingdom)
Objectives: Many youth with tics experience distress about having tics and how others may perceive them. Such symptoms are often more impairing and distressing than are the tics and negatively impact self-concept, functioning, and quality of life. Although treatments exist that target the frequency and severity of tics, no intervention has been developed that helps youth with tics cope with their condition and limit associated functional impairment and distress. Given this, we developed a cognitive-behaviorally oriented psychotherapy protocol that promotes adaptive coping and resiliency among youth with tics in addressing varied issues commonly experienced by this population. This poster reports data from the Phase I component of this study. Method: Phase I concentrated on developing the t...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
Objectives The optimal timing of pyeloplasty for children diagnosed with ureteropelvic junction obstruction (UPJO) after workup for antenatal hydronephrosis is disputed. We sought to examine the potential costs and clinical outcomes of treatment protocols featuring different indications for pediatric pyeloplasty using Markov models. Methods Cost and outcomes analysis using Markov modeling was performed for three treatment algorithms: medical management, immediate pyeloplasty (during the first year of life), and pyeloplasty after no improvement on imaging. The costs were determined from the perspective of the medical institution. The variables tracked during Markov model simulation included age at resolution of UPJO, the proportion of patients with worsened hydronephrosis, the number of pye...
2008-01-01
Optimized assay and storage conditions for enzyme activity profiling of ectomycorrhizae
British Library Electronic Table of Contents (United Kingdom)
The aim of a joint effort by different research teams was to provide an improved procedure for enzyme activity profiling of field-sampled ectomycorrhizae, including recommendations on the best conditions and maximum duration for storage of ectomycorrhizal samples. A more simplified and efficient protocol compared to formerly published procedures was achieved by using manufactured 96-filter plates in combination with a vacuum manifold and by optimizing incubation times. Major improvements were achieved by performing the series of eight enzyme assays with a single series of root samples instead of two series, reducing the time needed for sample preparation, minimizing error-prone steps such as pipetting and morphotyping, and facilitating subsequent DNA analyses due to the reduced sequencing ...
2011-01-01
Ocular Burn: Rinsing and Healing with Ionic Marine Solutions and Vegetable Oils
British Library Electronic Table of Contents (United Kingdom)
Abstract Purpose: We investigated the effects of various rinsing and healing protocols on corneal wound repair and inflammation following alkali burn in rabbits. Methods: We conducted in vitro, in vivo and ex vivo studies. First, different rinse solutions were tested in vitro after incubation of ocular cells with methanol or NaOH. Cell viability was then assessed using the neutral red test (cytofluorometry). Second, NaOH was applied to rabbit corneas and associations of rinse solutions (NaCl 0.9% or controlled ionization marine solutions) with N-acetylcysteine or vegetable oils (from Calophyllum inophyllum and Aleurites moluccana) were tested in vivo. The regeneration of the corneal epithelium and the infiltration of inflammatory cells were evaluated using in vivo confocal microscopy and e...
2009-01-01
Novel reduced pressure-balance syringe for chromatographic analysis
British Library Electronic Table of Contents (United Kingdom)
When withdrawing a fluid sample (for additional chromatographic analyses) from an apparatus operated at a reduced pressure, a typical syringe proves to be ineffective (even if it is equipped with a gas tight plunger). It simply does not create enough pressure differential to remove a fluid sample from a reduced pressure environment. We encountered such a situation as part of efforts to extend the operation of the advanced distillation curve protocol to reduced pressures. The problem was solved by the development of a pressure balance syringe that allows reliable and precise sampling from an apparatus operating at sub-ambient pressures. This new device uses an external vacuum source to evacuate a syringe barrel, allowing a user to withdraw fluid samples from environments with pressures as l...
2010-01-01
New Radiation Stable and Long-Lived Plastic Scintillators
International Nuclear Information System (INIS)
A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiation hardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiation hardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is shown that one of the main reasons for aging of plastic scintillators is residual monomer. 10 refs., 18 figs., 1 tab.
1993-11-15
Network management of real-time embedded processors
International Nuclear Information System (INIS)
The Superconducting super Collider Laboratory is a complex of particle accelerators being built in Ellis County, Texas. It will have a dedicated global communications network that will deliver control messages and provide for general data acquisition. This network will connect thousands of computer nodes over a very large geographic area. In order to meet the demanding availability requirements being levied on the system, it will need comprehensive network management. A large number of the computer nodes are embedded systems that traditionally do not support network management services. This presents unique challenges to standard network management practices. The Simple Network Management Protocol, SNMP, is widely accepted by industry as a tool to manage network devices. In this paper the authors examine the performance characteristics and usefulness of an SNMP agent in a real-time environment.
1993-05-17
Network Security Mechanisms Utilizing Dynamic Network Address Translation LDRD Project
A new protocol technology is just starting to emerge from the laboratory environment. Its stated purpose is to provide an additional means in which networks, and the services that reside on them, can be protected from adversarial compromise. This report has a two-fold objective. First is to provide the reader with an overview of this emerging Dynamic Defenses technology using Dynamic Network Address Translation (Dynat). This ''structure overview'' is concentrated in the body of the report, and describes the important attributes of the technology. The second objective is to provide a framework that can be used to help in the classification and assessment of the different types of dynamic defense technologies along with some related capabilities and limitations. This information is primarily contained in the appendices.
2002-11-01
Multi-centre evaluation of the urine test strip analyser Rapimat.
A multi-centre evaluation of the test strip analyser, Rapimat, was performed by four laboratories following the ECCLS 2nd draft guidelines for the evaluation of analysers in clinical chemistry. Using the Rapignost urine test strip with the test fields for bilirubin, urobilinogen, acetoacetate, ascorbic acid, glucose, protein, nitrite, pH and haemoglobin, the Rapimat was found to be analytically reliable in comparison with other, in most cases quantitative procedures. During the observation period of about 6 months no breakdown occurred in any laboratory. Interferences and sensitivity as discussed for the bilirubin and urobilinogen test field are more related to the test strip than to the instrument. Several improvements for further developments are suggested. This multi-centre study has shown that the ECCLS protocol is applicable to analytical procedures leading to discrete results. PMID:4056663
1985-08-01
Memory of multiple aging stages above the freezing temperature in the Relaxor ferroelectric PLZT.
The dynamic dielectric susceptibility and the elastic compliance of the relaxor ferroelectric lanthanum lead zirconate titanate (PLZT) 9/65/35 have been measured under different cooling and heating protocols in order to study aging and memory. The memory of multiple aging stages at different temperatures has been found (several dips in the susceptibility curves on heating), as in spin glass systems below the glass transition. Remarkably, in PLZT the memory of several aging stages is retained also above the freezing temperature deduced from the dynamic susceptibilities. The results are discussed in light of the existing models of aging and memory in spin and dipolar glasses. PMID:15447139
2004-08-24
Mammary carcinogenesis in the rat after low-dose irradiation
International Nuclear Information System (INIS)
Carcinogenesis is now generally recognized to be an important detrimental effect in man after low dose irradiation. The carcinogenic action of ionizing radiation is clearly demonstrated after exposure to relatively high doses (in excess of 0.5 Gy) but for lower dose levels reliable direct observations are not available. With the introduction of special protocols for the performance of large scale screening programs by mammography the average absorbed dose in glandular tissue in the average breast can be restricted to a value of 3 mGy per mammogram. The risk for tumor induction after exposure to these low doses can never be established from human epidemiology. In order to investigate the risk of repeated exposure to small dose of ionizing radiation the induction of mammary tumors has been investigated in rats of the WAG/Rij strain after single and fractionated irradiations with gamma-rays. (author). 8 refs., 3 figs.
1992-07-12
Local control of Ewing's sarcoma of bone with radiotherapy and combination chemotherapy
International Nuclear Information System (INIS)
Between 1964 and 1977, 94 patients with Ewing's sarcoma of bone were treated at the National Cancer Institute. They received 5000 rad to the whole bone and progressively more aggressive chemotherapy protocols. The patients were divided according to site of primary lesion into central, proximal and distal lesions, with 19%, 33% and 57%, respectively, alive and well. The local control rate is high (93%), with good functional results in the distal lesions, and no changes are needed in radiation therapy dose or volume. Control is not as satisfactory for central and proximal lesions and efforts need to be made to increase control at these sites. We are at present attempting to define more accurately the extent of soft tissue disease, increasing the dose to 6000 rad for central lesions, and using a more aggressive chemotherapy program, in the hope of increasing the local control in these more aggressive tumors.
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial.Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol.Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed co...
2007-01-01
Geochemical modelling of acidification and recovery in forest soils and runoff waters
Energy Technology Data Exchange (ETDEWEB)
The Model of Acidification of Groundwaters in Catchments (MAGIC) was used to simulate the impact of acidifying deposition and future recovery at the Gaardsjoen Covered Catchment Experiment, at a number of hypothetical stations defined by statistical variation of the Gaardsjoen data and at 20 forest monitoring sites in Southern Sweden. For the future predictions a decrease of sulphur deposition of more than 70% was assumed. This assumption is based on a full implementation of the agreements made under the second sulphur protocol from 1994. The modelled impact of reduced deposition on the soils and on the runoff waters was discussed. To complement the discussion on long-term trends in future run-off chemistry, data from Gaardsjoen has been used to asses the risk for short-term acid runoff episodes 26 refs, 23 figs, 7 tabs
1999-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract In response to growing consumer concerns, developed-country governments have reduced permissible pesticide residue levels in food. Many food retailers have developed even more stringent private food safety protocols relating to pesticide use, storage and disposal and passed them on to their suppliers. Exporters in developing countries enforce these developed-country pesticide standards (DC-PS) by subjecting farmers to close monitoring. This study explores the effects of enforcing compliance with DC-PS on smallholder farmers' pesticide-related health costs. Results suggest that enforcing DC-PS encourages farmers to use protection that lowers pesticide-induced morbidity, hence reducing farmers' health costs from pesticide exposure. The study concludes that there are health benefits ...
2010-01-01
Forming the COUNCIL Based Clusters in Securing Wireless Ad Hoc Networks
In cluster-based routing protocol (CBRP), two-level hierarchical structure is successfully used to reduce over-flooding in wireless Ad Hoc networks. As it is vulnerable to a single point of failure, we propose a new adaptive distributed threshold scheme to replace the cluster head by a group of cluster heads within each cluster, called COUNCIL, and distribute the service of single cluster head to multiple cluster heads using (k,n) threshold secret sharing scheme. An Ad Hoc network formed by COUNCIL based clusters can work correctly when the number of compromised cluster heads is smaller than k. To implement this adaptive threshold scheme in wireless Ad Hoc Networks, membership of the clusters should be defined in an adaptive way. In this paper, we mainly discuss our algorithm for forming COUNCIL based clusters using the concept of dominating set from graph theory.
2010-01-01
Formaldehyde surface-emission monitor. Protocol I: pressed-wood products
Energy Technology Data Exchange (ETDEWEB)
The formaldehyde surface emission monitor (FSEM) has been developed for passive non-destructive measurement of formaldehyde (CH/sub 2/O) emission rates from CH/sub 2/O resin-containing materials. It is envisaged as a potential quality control and in-situ monitoring technique. For quality control applications to pressed-wood products, strong correlations between the results of the FSEM and environmentally controlled (small scale) chamber tests were observed. The FSEM is used to measure the cumulative CH/sub 2/O emission from a finite area of pressed-wood product during a fixed test period. The final result is reported as an average CH/sub 2/O emission rate (mg CH/sub 2/O/m/sup 2/h).
1983-06-01
Explicit Randomness is not Necessary when Modeling Probabilistic Encryption
Although good encryption functions are probabilistic, most symbolic models do not capture this aspect explicitly. A typical solution, recently used to prove the soundness of such models with respect to computational ones, is to explicitly represent the dependency of ciphertexts on random coins as labels. In order to make these label-based models useful, it seems natural to try to extend the underlying decision procedures and the implementation of existing tools. In this paper we put forth a more practical alternative based on the following soundness theorem. We prove that for a large class of security properties (that includes rather standard formulations for secrecy and authenticity properties), security of protocols in the simpler model implies security in the label-based model. Combined with the soundness result of (\\textbf{?}) our theorem enables the translation of security results in unlabeled symbolic models to computational security.
2006-01-01
Ethernet networks technology in electrical substations
Energy Technology Data Exchange (ETDEWEB)
In both office and home environments, Ethernet represents the dominant networking technology in use. Ethernet is low cost and the networks are fairly understood by users. The author began by explaining the physical and data link layers of Ethernet, then touched on fibre-optic cables. The industrial protocols were discussed, followed by Ethernet network topology. The environmental robustness of Ethernet networks was reviewed, with a word of caution from the author, advising to properly evaluate whether Ethernet represents a mission-critical component of the substation, as substation control houses are not environmentally controlled spaces, often minimally heated and no cooling. Engineering access to station Integrated Electric Drives (IEDs). By properly connecting Ethernet networks, it is possible to access relays in the substations from desktop engineering workstations in the central office. Network security issues must be addressed to prevent unauthorized access ...
2002-07-01
Engineering TCP transmission and retransmission mechanisms for wireless networks
British Library Electronic Table of Contents (United Kingdom)
Transmission Control Protocol (TCP) provides mechanisms for reliable data communications. Although it works well in wired networks, it fails to offer satisfactory performance in lossy and wireless environments. And in the multi-hop wireless infrastructure, packet delivery suffers high cumulative loss rate if traveling over multiple wireless hops. The Selective acknowledgment (SACK) is one header option that might be used to combat segment corruptions in air channels. In this paper, an alternative set of flow control mechanisms is proposed to handle high packet loss rate in a wireless medium. Using a measurement-based mechanism, sustainable segment delivery is achievable through a novel size-reduction method. Multiple segment retransmission mechanisms are introduced to reduce successive tim...
2011-01-01
Efficient Queue-based CSMA with Collisions
Recently there has been considerable interest in the design of efficient carrier sense multiple access(CSMA) protocol for wireless network. The basic assumption underlying recent results is availability of perfect carrier sense information. This allows for design of continuous time algorithm under which collisions are avoided. The primary purpose of this note is to show how these results can be extended in the case when carrier sense information may not be perfect, or equivalently delayed. Specifically, an adaptation of algorithm in Rajagopalan, Shah, Shin (2009) is presented here for time slotted setup with carrier sense information available only at the end of the time slot. To establish its throughput optimality, in additon to method developed in Rajagopalan, Shah, Shin (2009), understanding properties of stationary distribution of a certain non-reversible Markov chain as well as bound on its mixing time is essential. This note presents these key results. A ...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
A study was undertaken to assess the effect of different storage temperatures on senescence and postharvest performance of isolated flowers of Ranunculus asiaticus L.. The main aim of the work was to develop a cost-effective storage protocol to reduce the postharvest losses and to bring out the transportation of cut flowers of R. Asiaticus. The flowers were subjected to two different storage treatments, dry storage and wet storage, and their postharvest performance was compared under laboratory conditions. For this purpose, the buds were harvested at 8:00 AM at loose bud stage (Stage II of flower development). The harvested buds were cut to a uniform size of 15 cm and processed for dry or wet storage. For dry storage, the buds were packed after wrapping them in moistened filter papers and ...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Effect of Abdominal Active Can on DFTs. Introduction: Many patients with implantable cardioverter defibrillators (ICDs) have older lead systems, which are usually not replaced at the time of pulse generator replacement unless a malfunction is noted. Therefore, optimization of defibrillation with these lead systems is clinically important. The objective of this prospective study was to determine if an active abdominal pulse generator (Can) affects chronic defibrillation thresholds (DFTs) with a dual-coil, transvenous ICD lead system. Methods and Results: The study population consisted of 39 patients who presented for routine abdominal pulse generator replacement. Each patient underwent two assessments of DFT using a step-down protocol, with the order of testing randomized. The distal right ...
2006-01-01
British Library Electronic Table of Contents (United Kingdom)
Background: Ventricular repolarization (VR) is strongly influenced by heart rate (HR) and autonomic nervous activity, both of which also are important for arrhythmogenesis. Their relative influence on VR is difficult to separate, but might be crucial for understanding while some but not other individuals are at risk for life-threatening arrhythmias at a certain HR. This study was therefore designed to assess the -pure- effect of HR increase by atrial pacing on the ventricular gradient (VG) and other vectorcardiographically (VCG) derived VR parameters during an otherwise unchanged condition. Methods: In 19 patients with structurally normal hearts, a protocol with stepwise increased atrial pacing was performed after successful arrhythmia ablation. Conduction intervals were measured on averag...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
ABSTRACT Purpose: The aim of this two-center study was to evaluate screw-type titanium implants with a chemically modified, sandblasted and acid-etched surface when placed in the posterior maxilla or mandible, and loaded 21 days after placement. Material and Methods: All 56 patients met strict inclusion criteria and provided informed consent. Each patient displayed either a single-tooth gap, an extended edentulous space, or a distal extension situation in the posterior mandible or maxilla. Eighty-nine dental implants (SLActive, Institut Straumann AG, Basel, Switzerland) were inserted according to an established nonsubmerged protocol and underwent undisturbed healing for a period of 21 days. Where appropriate, the implants were loaded after 21 days of healing with provisional restorations i...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
A novel PCR based assay was devised to specifically detect contamination of any Salmonella serovar in milk, fruit juice and ice-cream without pre-enrichment. This method utilizes primers against hilA gene which is conserved in all Salmonella serovars and absent from the close relatives of Salmonella. An optimized protocol, in terms time and money, is provided for the reduction of PCR contaminants from milk, ice-cream and juice through the use of routine laboratory chemicals. The simplicity, efficiency (time taken 3-4 h) and sensitivity (to about 5-10 CFU/ml) of this technique confers a unique advantage over other previously used time consuming detection techniques. This technique does not involve pre-enrichment of the samples or extensive sample processing, which was a pre-requisite in mos...
2012-01-01
British Library Electronic Table of Contents (United Kingdom)
The National Food and Nutrient Analysis Program (NFNAP) was implemented in 1997 to update and improve the quality of food composition data maintained by the United States Department of Agriculture (USDA). NFNAP was designed to sample and analyze frequently consumed foods in the U.S. food supply using statistically rigorous sampling plans, established sample handling procedures, and qualified analytical laboratories. Methods for careful handling of food samples from acquisition to analysis were developed to ensure the integrity of the samples and subsequent generation of accurate nutrient values. The infrastructure of NFNAP, under which over 1500 foods have been sampled, mandates tested sample handling protocols for a wide variety of foods. The majority of these foods were categorized into ...
2010-01-01
Development of a robotics system for automated chemical analysis of sediment, sludges, and soils
International Nuclear Information System (INIS)
The introduction of automation technology into the analytical laboratory holds the promise of higher efficiency, improved productivity, and lower costs. However, the conventional ''laboratory robot'' widely used today may not offer the work envelope or reliability required in a high workload laboratory performing quality control or environmental analytical services. To address this need, a demonstration workcell was assembled utilizing an industrial-class robotics system to automate a standard EPA acid digestion protocol. With further development of graphical user interfaces and error recovery software, the technology will significantly enhance the ability of laboratories to meet increasingly complex environmental demands. 7 refs., 2 figs., 1 tab.
1989-11-26
Delay-Limited Cooperative Communication with Reliability Constraints in Wireless Networks
We investigate optimal resource allocation for delay-limited cooperative communication in time varying wireless networks. Motivated by real-time applications that have stringent delay constraints, we develop a dynamic cooperation strategy that makes optimal use of network resources to achieve a target outage probability (reliability) for each user subject to average power constraints. Using the technique of Lyapunov optimization, we first present a general framework to solve this problem and then derive quasi-closed form solutions for several cooperative protocols proposed in the literature. Unlike earlier works, our scheme does not require prior knowledge of the statistical description of the packet arrival, channel state and node mobility processes and can be implemented in an online fashion.
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
Abstract This study aimed at developing a suitable cryopreservation protocol for embryonic stem (ES)-like cells of a tiny freshwater fish Leopard danio (Brachydanio frankei). Embryonic stem (ES)-like cells derived from blastomeres of the early blastulae stage of the developing embryo were cultured in vitro in a medium containing Leibowitz-15 supplemented with 10% foetal bovine serum, leopard danio embryo extract, sodium bicarbonate, sodium selenite, basic fibroblast growth factor, epidermal growth factor and leukaemia inhibitory factor. The ES-like cells showed properties similar to ES cells in other species. They were morphologically small, round to polygonal and present in patches and extensively expressed alkaline phosphatase and stage-specific embryonic antigen. The toxicity and chilli...
2010-01-01
Core testing of zinc/air refuelable battery modules
Energy Technology Data Exchange (ETDEWEB)
We are developing a refuelable zinc/air battery (6-cells) for evaluation under the five USABC `core` test protocols. In the first half of the two year project ($1OOK, FY1997), an advanced refuelable design was developed, fabricated and tested at power levels up to 415 W. Performance matched or exceeded that of earlier multicell systems. A computer program was developed for automated data acquisition and drive cycle simulation. Small mockup cells (80 cm 2) were constructed for rapid testing of components. In the follow-on effort (FY1998, $1OOK) we will make minor advances in system design and fabrication efficiency, and seek to improve cathode performance and life, before delivery of two final units for test at DOE laboratory.
1998-08-20
Code Verification by the Method of Manufactured Solutions
Energy Technology Data Exchange (ETDEWEB)
A procedure for code Verification by the Method of Manufactured Solutions (MMS) is presented. Although the procedure requires a certain amount of creativity and skill, we show that MMS can be applied to a variety of engineering codes which numerically solve partial differential equations. This is illustrated by detailed examples from computational fluid dynamics. The strength of the MMS procedure is that it can identify any coding mistake that affects the order-of-accuracy of the numerical method. A set of examples which use a blind-test protocol demonstrates the kinds of coding mistakes that can (and cannot) be exposed via the MMS code Verification procedure. The principle advantage of the MMS procedure over traditional methods of code Verification is that code capabilities are tested in full generality. The procedure thus results in a high degree of confidence that all coding mistakes which prevent the equations from being solved correctly have been identified.
2000-06-01
British Library Electronic Table of Contents (United Kingdom)
Abstract A novel and convenient protocol for the preparation of an open-tubular column coated with chitosan-silica hybrid using chitosan and silane-coupling agent (-glycidoxy-propyltrimethoxysilane) was developed for CEC, in which, chitosan was covalently bonded to the inner wall of a fused-silica capillary using -glycidoxy-propyltrimethoxysilane as a cross-linking agent. The stationary phase was hydrophilic due to the chitosan-silica hybrid with abundant amine and hydroxyl functional groups. The chromatographic characteristics of the column were evaluated by the separation of some organic acids and inorganic anions. The column showed good selectivity for nucleotides, aromatic acids, and inorganic anions. The mechanism for the separation of these compounds was primarily based on the hydrop...
2011-01-01
Cardiopulmonary fitness and endurance in children with developmental coordination disorder
British Library Electronic Table of Contents (United Kingdom)
The purpose of this study was to compare cardiopulmonary fitness and endurance in 9-11-year-old children with DCD against a group of typically developing children in Taiwan. The Movement ABC test was used to evaluate the motor abilities of children. Forty-one participants (20 children with DCD and 21 children without DCD) were recruited for this study. The cardiopulmonary tests included the 800-m run test and the peak oxygen consumption (peak VO2) test using the Bruce treadmill protocol. No significant differences in age, body height, body weight, body mass index, and percentage of body fat between children with DCD and without DCD were found. However, there were significant differences in the cardiopulmonary endurance tests between children with DCD and without DCD. Children with DCD had ...
2010-01-01
Beyond the tropics: forest structure in a temperate forest mapped plot
British Library Electronic Table of Contents (United Kingdom)
Abstract Question: How do the diversity, size structure, and spatial pattern of woody species in a temperate (Mediterranean climate) forest compare to temperate and tropical forests? Location: Mixed evergreen coastal forest in the Santa Cruz Mountains, California, USA. Methods: We mapped, tagged, identified, and measured all woody stems (?1 cm diameter) in a 6-ha forest plot, following Center for Tropical Forest Science protocols. We compared patterns to those found in 14 tropical and 12 temperate forest plots. Results: The forest is dominated by Douglas-fir (Pseudotsuga menziesii) and three species of Fagaceae (Quercus agrifolia, Q. parvula var. shrevei, and Lithocarpus densiflorus), and includes 31 woody species and 8180 individuals. Much of the diversity was in small-diameter shrubs,...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
From the beginning of the 90s the analysis of the relationships between economic growth and environmental pressures has been influenced by the Environmental Kuznets Curve hypothesis or inverted-U shaped relationship between environmental pressure and per capita income. Following this hypothesis, once achieved certain income level, more economic growth is followed by environmental quality improvement. In this paper, we analyse and discuss the theories that support this hypothesis as well as the empirical evidence on this subject. Further on we analyse the relationship between per capita income and the main environmental pollutants for the case does not support the hypothesis. The empirical evidence shows that economic growth, by itself, does not entail a pollution reduction. (Author) 35 refs.
2004-07-01
Energy Technology Data Exchange (ETDEWEB)
Fifty-nine patients underwent free flap osteocutaneous reconstruction that consisted of flaps of the dorsum of the foot in 26 patients and iliac crest flaps in 33 with a success rate of 92 percent and a mortality rate of 1.6 percent. These flaps, which require the expertise of microvascular surgeons, are time-consuming and complicate operating room and time management, but they represent a remarkable advance in reconstruction that can facilitate cosmetic and functional recovery of the patient. In particular, they promote healing in radiation-recurrent oral cancer and represent a definitive form of management for established radionecrosis of the mandible. The large volume of tissue available with iliac crest osteocutaneous grafts permits the management of patients with extensive cancer involving the skin, mucosa, and bone, but cancer control may still be disappointing and there is a need for improved adjuvant chemotherapy protocols. This technique appears to be a ...
1985-10-01
British Library Electronic Table of Contents (United Kingdom)
An efficient micropropagation protocol was established for Cryptocoryne wendtii and Cryptocoryne becketti using shoot tips explants. Multiple shoots were induced from shoot tip explants of both species cultured on agar-gelled as well as liquid MS medium supplemented with 0.5?mg/L BA and 0.2?mg/L IBA (proliferation medium). The multiple shoots of both the species formed on agar-gelled as well as liquid medium were vigorously growing with well-developed roots and leaves after 4?weeks of culture. Highest number of multiple shoots was obtained from shoot tip explants of both the species cultured in liquid proliferation medium after 4?weeks of culture. The shoot tip explants of C. wendtii and C. becketti, that were cultured in liquid proliferation medium (2?weeks) followed by culturing on agar-...
2011-01-01
A radiation monitoring system for nuclear fusion devices
International Nuclear Information System (INIS)
Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)
2005-12-01
British Library Electronic Table of Contents (United Kingdom)
A sensitive and rapid method to evaluate toxic and genotoxic properties of drinking water supplied from Lake Trasimeno (Umbria, Central Italy) was worked out analysing bile in Cyprinus carpio exposed for 20d to lake water treated with 3 different disinfectants, sodium hypochlorite (NaClO), chlorine dioxide (ClO2) and peracetic acid (PAA). Fish were sacrificed at 0, 10 and 20d in order to investigate the time course of these endpoints. An aliquot of bile samples was fractionated by adsorption on C18 silica cartridges and the genotoxic potential of whole bile and of bile fractions was evaluated by the single-cell microgel-electrophoresis (comet) assay on human colonic adenocarcinoma cells (Caco-2). Bile (both whole and fractionated) from specimens exposed to the three disinfectants always sh...
2011-01-01
International Nuclear Information System (INIS)
A very simple theoretical scheme is proposed to implement two- and three-qubit controlled-phase gates firstly only using a single resonant interaction between ladder-type three-level atoms and the single-mode cavity. In the presented protocol, the quantum information is encoded on the stable ground states of the atoms (as the controlling qubits) and the zero- and one-photon Fock states of cavity-field (as the target qubit). Under the influence of the atomic spontaneous emission, the decay of the cavity-mode, and deviation of the coupling strength, the three-qubit controlled-phase gate may have a comparatively high fidelity. The experimental feasibility of controlled-phase gate and the case that is extended to realize N-qubit controlled-phase gate are also discussed. (general)
2010-03-15
International Nuclear Information System (INIS)
As a continuation of its efforts to provide methodologies and tools to Member States to carry out comparative assessment and analyse priority environmental issues related to the development of the electric power sector, the IAEA has completed a new version of the Wien Automatic System Planning (WASP) Package WASP-IV for carrying out power generation expansion planning taking into consideration fuel availability and environmental constraints. This manual constitutes a part of this work and aims to provide users with a guide to use effectively the new version of the model WASP-IV. WASP was originally developed in 1972 by the Tennessee Valley Authority and the Oak Ridge National Laboratory in the USA to meet the IAEA needs to analyse the economic competitiveness of nuclear power in comparison to other generation expansion alternatives for supplying the future electricity requirements of a country or region. Previous versions of the model were used ...
1997-12-01
Phase 2 Final Report. IAEA Safeguards: Implementation blueprint of commercial satellite imagery
International Nuclear Information System (INIS)
This document - IAEA Safeguards: Implementation Blueprint of Commercial Satellite Imagery - constitutes the second report from SSC Satellitbild giving a structured view and solid guidelines on how to proceed with a conceivable implementation of satellite imagery to support Safeguards activities of the Agency. This Phase 2 report presents a large number of concrete recommendations regarding suggested management issues, work organisation, imagery purchasing and team building. The study has also resulted in several lists of actions and preliminary project plans with GANT schedules concerning training, hardware and software, as well as for the initial pilot studies. In both the Phase 1 and Phase 2 studies it is confirmed that the proposed concept of a relatively small Imagery Unit using high-resolution data will be a sound and feasible undertaking. Such a unit capable of performing advanced image processing as a tool for various safeguard tasks will give the Agency an ...
1989-08-01
International Nuclear Information System (INIS)
Purpose. To validate a protocol for creating virtual models to be used in the construction of solid prototypes useful for the planning-simulation of maxillo-facial surgery, in particular for very complex anatomical and pathologic problems. To optimize communications between the radiology, engineering and surgical laboratories. Methods and materials. We studied 16 patients with different clinical problems of the maxillo-facial district. Exams were performed with multidetector computed tomography (MDCT) and single slice computed tomography (SDCT) with axial scans and collimation of 0.5-2 mm, and reconstruction interval of 1 mm. Subsequently we performed 2D multiplanar reconstructions and 3D volume-rendering reconstructions. We exported the DICOM images to the engineering laboratory, to recognize and isolate the bony structures by software. With these data the solid prototypes were generated using stereolitography. To date, surgery has been preformed on 12 patients ...
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
The paper addresses the major items of relevance to compensation for nuclear damage under civil liability law. The revision of the Vienna Convention deserves support as a contribution to enhancing the protection of those who suffered damage, and of the environment. The results of the revision will have an impact on the liability regimes in existing and future signatory states, and to some extent will also set the goals of a future reshaping of the Paris Convention, all the more since the Joint Protocol calls for harmonization of at least basic provisions of substantive law in the two Conventions. (orig./HP) [Deutsch] Es werden die wesentlichen Punkte dargestellt, die fuer die zivilrechtliche Praxis im Schadensfall von Belang sein koennten. Die Revision ist als Beitrag zu einem verbesserten Schutz Geschaedigter, aber auch der Umwelt zu begruessen und zu unterstuetzen. Die Ergebnisse werden sich auf die Rechtsordnungen der gegenwaertigen und zukuenftigen ...
1995-12-31
Energy Technology Data Exchange (ETDEWEB)
To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer ...
2001-07-01
Prognostic factors in the treatment of Ewing's sarcoma
International Nuclear Information System (INIS)
From 1981 up to February 1985, a total of 93 protocol patients entered the study CESS 81. The protocol recommended an initial 18-week period of polychemotherapy (VACA) followed by local therapy and two additional cycles of chemotherapy. Local therapy consisted either of radical surgery or of incomplete resection plus postoperative irradiation with 36 Gy or of radiotherapy alone (46 and 60 Gy). Centrally located lesions were always irradiated with 60 Gy. This article summarizes the data after 5 years. Data of 93 patients were analysed in October 1986 after a median follow-up of 37 months. The projected 5-year survival is 50%. The relapse rate was 42%, distant relapses occurred in 19%, local (plus distant) relapses in 23%. Most of the relapses occurred during the first 3 years of observation. Failure rate was high in patients undergoing irradiation alone (44%). Initial tumour mass (> 100 ml) and histopathologic response to initial chemotherapy ...
International Nuclear Information System (INIS)
Purpose: To identify results and prognostic factors on long-term survival and local control following treatment of localized Ewing's sarcoma. Patients and Methods: Between 1979 and 2004, a total of 60 children and young adults with Ewing's sarcoma were treated. Patients with distant metastases at presentation (n = 6) and recurrent cases (n = 2) were excluded from this analysis. Patients were exclusively treated within ongoing national and international protocols CESS-81, CESS-86, EICESS-92, EURO-EWING-99. All patients received local irradiation with a total dose of 45-60 Gy; in addition, 41 (79%) of the patients had local surgical procedures, 27 (52%) of them with clear margins. Results: Overall survival rates at 5 and 10 years were 56% and 45%, respectively. Patients #<=# 14 years at diagnosis had overall survival rates of 66% and 61% at 5 and 10 years compared to older patients with corresponding survival rates of 47% and 31%, respectively (p = 0.05). Patients ...
2008-03-01
Interinstitutional Variations in Planning for Stereotactic Body Radiation Therapy for Lung Cancer
International Nuclear Information System (INIS)
Purpose: The aim of this study was to assess interinstitutional variations in planning for stereotactic body radiation therapy (SBRT) for lung cancer before the start of the Japan Clinical Oncology Group (JCOG) 0403 trial. Methods and Materials: Eleven institutions created virtual plans for four cases of solitary lung cancer. The created plans should satisfy the target definitions and the dose constraints for the JCOG 0403 protocol. Results: FOCUS/XiO (CMS) was used in six institutions, Eclipse (Varian) in 3, Cadplan (Varian) in one, and Pinnacle3 (Philips/ADAC) in one. Dose calculation algorithms of Clarkson with effective path length correction and superposition were used in FOCUS/XiO; pencil beam convolution with Batho power law correction was used in Eclipse and Cadplan; and collapsed cone convolution superposition was used in Pinnacle3. For the target volumes, the overall coefficient of variation was 16.6%, and the interinstitutional variations were not ...
2007-06-01
International Nuclear Information System (INIS)
Patients with Ewing's sarcoma who present with a central axis or proximal extremity primary and/or with metastatic disease have a poor prognosis despite aggressive combination chemotherapy and local irradiation. In this high risk group of patients, total body irradiation (TBI) has been proposed as a systemic adjuvant. To aid in the design of a clinical TBI protocol, the authors have studied in the in vitro radiation response of two established cell lines of Ewing's sarcoma and human bone marrow CFUc. The Ewing's lines showed a larger D_0 and anti-n compared to the bone marrow CFU. No repair of potentially lethal radiation damage (PLDR) was found after 4.5 Gy in plateau phase Ewing's sarcoma cells. A theoretical split dose survival curve for both the Ewing's sarcoma lines and human bone marrow CFUc using this TBI schedule shows a significantly lower surviving fraction (10"-"4-10"-"5) for the bone marrow CFUc. Based on these in vitro results, two 4.0 Gy fractions ...
Host based internet protocol (IP) packet analysis to enhance network security
International Nuclear Information System (INIS)
Data communication in a computer network environment is facing serious security threats from numerous sources such as viruses, worms, Zombies etc. These threats can be broadly characterized as internal or external security threats. Internal threats are mainly attributed to sneaker-nets, utility modems and unauthorized users, which can be minimized by skillful network administration, password management and optimum usage policy definition. The external threats need more serious attention as these attacks are mostly coming from public networks such as Internet. Frequency and complexity of such attacks is much higher as compared to internal attacks. This paper presents a host based network layer screening of external and internal IP packets for logging, analyzing and real-time detection of possible IP spoofing and Denial of Service attacks. This work can also be used in tuning security rules definition for gateway firewalls. Software has been developed which intercepts IP traffic and ...
2007-01-01
Effects of several variables on whole effluent toxicity test performance and interpretation
Energy Technology Data Exchange (ETDEWEB)
Protocol changes and options contained within US Environmental Protection Agency whole effluent toxicity tests represent variables that have the potential to affect bioassay performance and interpretation of results. Variables evaluated in this study include: the change in allowable age in the Pimephales promelas acute bioassay from up to 90 d to a maximum of 14 d, age-specific acute responses of P. promelas among the allowable ages of 1 to 14 d, change in the chronic growth endpoint definition from final mass to biomass, differences between hemacytometer and fluorometer measurements in the Selenastrum capricornutum protocol, and options for statistical interpretation of species sensitivity in multiple test/species screening bioassays. Clear age-related sensitivity and precision differences were observed in acute responses of P. promelas. Results obtained using the younger age classes were typically more variable in studies of both 1- to ...
2000-01-01
Effective dose estimation in whole-body multislice CT in paediatric trauma patients
Energy Technology Data Exchange (ETDEWEB)
The number of multislice CT (MSCT) scans performed in polytraumatized children has increased rapidly. There is growing concern regarding the radiation dose in MSCT and its long-term consequences, especially in children. To determine the effective dose to polytraumatized children who undergo whole-body MSCT. A total of 51 traumatized children aged 0-16 years underwent a polytrauma protocol CT scan between November 2004 and August 2006 at our institution. The effective dose was calculated retrospectively by a computer program (CT-Expo 1.5, Hannover, Germany). The mean effective dose was 20.8 mSv (range 8.6-48.9 mSv, SD{+-}7.9 mSv). There was no statistically significant difference in the effective dose between male and female patients. Whole-body MSCT is a superior diagnostic tool in polytraumatized children with 20.8 mSv per patient being a justified mean effective dose. In a potentially life-threatening situation whole-body MSCT provides the clinicians with ...
2009-03-15
Distribution of quantum information between an atom and two photons
Energy Technology Data Exchange (ETDEWEB)
The construction of networks consisting of optically interconnected processing units is a promising way to scale up quantum information processing systems. To store quantum information, single trapped atoms are among the most proven candidates. By placing them in high finesse optical resonators, a bidirectional information exchange between the atoms and photons becomes possible with, in principle, unit efficiency. Such an interface between stationary and ying qubits constitutes a possible node of a future quantum network. The results presented in this thesis demonstrate the prospects of a quantum interface consisting of a single atom trapped within the mode of a high-finesse optical cavity. In a two-step process, we distribute entanglement between the stored atom and two subsequently emitted single photons. The long atom trapping times achieved in the system together with the high photon collection efficiency of the cavity make the applied protocol in principle ...
2008-11-03
International Nuclear Information System (INIS)
A community greenhouse gas emission and energy inventory is an important tool to help local governments plan, implement and monitor climate change mitigation strategies and sustainable energy systems. Inventories can also facilitate a number of other local priorities such as air quality management; integrated land-use and transportation planning; infrastructure optimization and planning; and community economic development planning. The British Columbia government's community energy and emissions inventory initiative (CEEI) intends to collect and centralize high-quality geocoded data to generate high-value community inventories for the province's 185 local governments. This report presented strategic guidance for a comprehensive community emissions inventory system based on a high level review of international best practices. The report described the project objective and scope; guiding principles; research methodology; and inventory limitations. The report provided observations, ...
International Nuclear Information System (INIS)
Full text: Founded in 1964, Ankara Nuclear Research and Training Center (ANRTC) conducts and facilitates the scientific activities including training (summer practice, MSc and Ph D studies in physics and chemistry, IAEA fellowship programs etc.), research and other studies in nuclear and related fields. As it's a part of main duties, ANRTC has analysis on the variety of samples, and radiation protection services commercially, for radiation workers in state, public and private sectors. Research, development and application projects implemented in this Center have mostly been supported by State Planning Organization (SPO) and Turkish Atomic Energy Authority (TAEA). In addition to the projects there are on going collaborative studies with some national Universities and International Atomic Energy Agency. The main activities carried out in ANRTC can be summarized as: studies on experimental nuclear physics, application of nuclear techniques such as XRF, XRD, Gamma, ...
2004-10-01
Screening for congenital hypothyroidism in Lebanon
International Nuclear Information System (INIS)
Full text.National programs of neonatal screening were introduced in most countries and have proved their effectiveness against different types of retardation in children. Congenital hypothyroidism is one of the most common causes of physical and mental retardation in children. Programs of screening have shown that the incidence of this disorder is ethnic-background: it is low in Africans: 1-32000 whereas it is 1-3500 and 1-5000 in Hispanic and European newborns respectively. No previous mass screening programs were done in Lebanon. For this purpose, this program was introduced in collaboration with the IAEA. Cord blood is spotted into circles on filter paper just after delivery. These samples are air-dried at room temperature and kept at 4 degree C. They are then collected from hospitals to be screened. In the laboratory, all samples are assayed for IRMA TSH first. Those showing high or borderline TSH level (20mU/L) are then assayed for RIA TT4. Only those showing ...
1999-11-02
Roles of the operator and the safety services in nuclear power plant quality assurance
International Nuclear Information System (INIS)
With regard to the operation of nuclear power plants, Electricite de France formally recognized in 1973 that it was necessary for safety reasons and economically acceptable to adopt organizational principles of quality assurance that would be applicable both to its own activities and to those of its suppliers. Generally speaking, the form and spirit of the quality assurance programme chosen is based largely on the Code of Practice No. 50-C-QA. In particular, the programme focuses on the flexible character of quality assurance requirements and stresses that in the final analysis product quality depends above all on those to whom the project has been assigned, because it is they who are responsible for meeting the quality objectives set. Ten years of experience with the suppliers of Electricite de France has shown that these suppliers, after some initial difficulty, have been able to adapt the application of quality assurance so as to achieve satisfactory quality as regards both safety ...
RAAN Conference. Support of Nuclear Power. Opening talk
International Nuclear Information System (INIS)
Nuclear power in Romania was initiated on the basis of CANDU reactor type technology, an option found to fulfill the requirements for a sustainable economic development, to support the electric energy demand of the country and to ensure the population and environment protection. The construction of the Cernavoda NPP was heavily based on the Romanian industry participation and basic and applied nuclear research national resources. The experience acquired from Cernavoda NPP Unit 1 will be fructified in the construction of Units 2-5 to be built. The Romanian Ministry of Education and Research implemented a nuclear national program for research and development taking into account the European Union requirements and recommendations, the cooperation with the IAEA - Vienna and the Romanian government policy on short and medium terms in the nuclear field. The research-development program targeted: the reactor physics and nuclear fuel management; the operation safety of ...
2002-09-06
NWIS MEASUREMENTS FOR URANIUM METAL ANNULAR CASTINGS
Energy Technology Data Exchange (ETDEWEB)
This report describes measurements performed with annular uranium metal castings of different enrichments to investigate the use of {sup 252}Cf-source-driven noise analysis measurements as a means to quantify the amount of special nuclear material (SNM) in the casting. This work in FY 97 was sponsored by the Oak Ridge Y-12 Plant and the DOE Office of Technology Development Programs. Previous measurements and calculational studies have shown that many of the signatures obtained from the source-driven measurement are very sensitive to fissile mass. Measurements were performed to assess the applicability of this method to standard annular uranium metal castings at the Oak Ridge Y-12 plant under verification by the International Atomic Energy Agency (IAEA) using the Nuclear Weapons Identification System (NWIS) processor. Before the measurements with different enrichments, a limited study of source-detector-casting moderator configurations was performed to enhance the ...
1998-03-13
International Symposium on Nuclear Energy SIEN 2009. Nuclear Power - A New Challenge
International Nuclear Information System (INIS)
The SIEN 2009 symposium organized by Romanian Nuclear Energy Association, AREN, in co-operation with Romanian Atomic Forum, ROMATOM, was primarily targeting the expert community involved in developing new nuclear power projects and implementing the National Nuclear Program. The symposium was also open as a discussion and information forum for scientists, engineers, technicians and students interested in scientific and technologic topics of Nuclear Power. It was structured in the following 6 sections: - Nuclear new builds and developments; - Operation, inspection and maintenance; - Increasing nuclear safety features; - Fuel cycle and decommissioning; - Public perception and confidence strengthening; - Environmental management. The symposium began with three plenary lectures dealing with: - Sustainable Nuclear Energy European Technology Platform; - Nuclear new-build; - Current issues of nuclear equipment standardization in Romania. A poster session of 5 presentations and a workshop ...
2009-10-12
Implementation strategies and tools for condition based monitoring at nuclear power plants
International Nuclear Information System (INIS)
There is now an acute need to optimize maintenance to improve both reliability and competitiveness of nuclear power plant operation. There is an increasing tendency to move from the preventive (time based) maintenance concept to one dependent on plant and component conditions. In this context, various on-line and off-line condition monitoring and diagnostics, nondestructive inspection techniques and surveillance are used. Component selection for condition based maintenance, parameter selection for monitoring condition, evaluation of condition monitoring results are issues influencing the effectiveness of condition based maintenance. All these selections of components and parameters to be monitored, monitoring and diagnostics techniques to be used, acceptance criteria and trending for condition evaluation, and the economic aspect of predictive maintenance and condition monitoring should be incorporated into an integrated, effective condition based maintenance programme, which is part of ...
2009-01-01
Economic evaluation of dual purpose desalination plants by fuel type in Korea
Energy Technology Data Exchange (ETDEWEB)
In light of the recent rapid increase in the fossil fuel prices it is meaningful to evaluate the impact of these price changes in the economics of dual-purpose desalination projects producing electricity and fresh water simultaneously. The price of crude oil and LNG (Liquefied Natural Gas) has increased by about 200% and 100% during the past three or four years. The uranium price has also increased by nearly 500% during the same period. The purpose of this paper is to analyze and compare the economics of SMART (System-integrated Modular Advanced ReacTor) which is being developed as a small size PWR type and the LNG Combine Cycle coupled with MED (Multi-Effect Distillation) which are being acknowledged as promising energy sources for the future in Korea. The methods of analysis used in this paper are the lifetime leveled cost method for the power and water cost calculation and the power credit method for the total cost allocation. DEEP (Devaluation Economic Evaluation Program) developed ...
2007-07-01
Economic evaluation of dual purpose desalination plants by fuel type in Korea
International Nuclear Information System (INIS)
In light of the recent rapid increase in the fossil fuel prices it is meaningful to evaluate the impact of these price changes in the economics of dual-purpose desalination projects producing electricity and fresh water simultaneously. The price of crude oil and LNG (Liquefied Natural Gas) has increased by about 200% and 100% during the past three or four years. The uranium price has also increased by nearly 500% during the same period. The purpose of this paper is to analyze and compare the economics of SMART (System-integrated Modular Advanced ReacTor) which is being developed as a small size PWR type and the LNG Combine Cycle coupled with MED (Multi-Effect Distillation) which are being acknowledged as promising energy sources for the future in Korea. The methods of analysis used in this paper are the lifetime leveled cost method for the power and water cost calculation and the power credit method for the total cost allocation. DEEP (Devaluation Economic Evaluation Program) developed ...
2007-05-13
International Nuclear Information System (INIS)
Within the United Kingdom, the regulatory body having responsibility for the licensing of nuclear installations is the Health and Safety Executive (HSE). The Nuclear Installations Inspectorate (NII) is that part of HSE which administers this function. Discussions on the applicability of quality assurance (QA) to licensed sites began in 1974, and an internal report was published in 1975. In parallel with work going on at the International Atomic Energy Agency (IAEA) to prepare Quality Assurance for Safety in Nuclear Power Plants: A Code of Practice, Safety Series No. 50-C-QA, NII published a second report in 1978 entitled A Guide to the Quality Assurance Programme for Nuclear Power Plants. In 1980, the construction of advanced gas cooled reactors at Heysham 2 and at Torness was licensed, and a condition was attached to the licences requiring the licensees to submit their QA arrangements to the NII for approval. The licensees' response was to produce separate QA ...
1988-11-07
Development of an irradiation system for a small size continuous run multipurpose gamma irradiator
International Nuclear Information System (INIS)
The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m"2 of floor area, the irradiator design is ...
Criticality calculations of the fixed bed nuclear reactor
Energy Technology Data Exchange (ETDEWEB)
The Fixed Bed Nuclear Reactor (FBNR) is a small 40 MWe reactor based on the Pressurized Water Reactor (PWR) technology. FBNR is an integrated primary circuit and simple in design. It has the characteristics of being small, modular, proliferation resistant, inherently safe and passively cooled reactor with reduced adverse environmental impact. It utilizes the fuel designed for high temperature reactors operating in a relatively low temperature of PWR environment The 15 mm diameter spherical fuel elements are made of TRISO type microspheres embedded in graphite and cladded by SiC. The coolant flow transfers them from the fuel chamber into the core and become fixed forming a suspended core. Any accident signal will cut off the power to the coolant pump causing a stop in the flow. This results in making the fuel elements fall out of the reactor core by the force of gravity and return into the fuel chamber where they are passively cooled under subcritical condition. Therefore, the ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
The pharmacological properties of medicinal plants have been related to the presence of organic compounds, however elements are also known to have an important participation in the active compounds constitution process. In this study, instrumental neutron activation analysis (INAA) was applied to determine elements in leaves of Casearia obliqua medicinal plant collected at two different locations in the Atlantic Forest, Brazil, SP. Soil samples collected from where this plant was grown were also analyzed in order to verify if there is a correlation between the elements present in soils and plant leaves. Br, Ca, Cl, Co, Cr, Cs, Fe, K, La, Mn, Na, Rb, Sb, Sc and Zn were determined in C. obliqua leaves and the elements As, Ca, Ce, Eu, Fe, Hf, La, Lu, Nd, Rb, Sc, Sm, Tb, Th, U and Zn in soils. Soil samples collected from two different locations presented similar concentrations for most elements. Likewise, C. obliqua leaves collected from the two locations presented similar elemental ...
2005-07-01
Annual report on heavy water reactor fuel fabrication
Energy Technology Data Exchange (ETDEWEB)
The CANDU-type nuclear fuel localization project started in 1981, and mass-production system completed in 1987 through the pilot scale demonstration of fuel manufacturing. Since the completion of the mass-production system, about 24,000 fuel bundles (450 ton-U) had been delivered to Wolsung Nuclear Power Plant by the end of 1992, according to the fuel supply contracts with KEPCO. The superiority of KAERI-made nuclear fuel has been demonstrated by having achieved the highest utilization factor in the world in 1992. In 1993, as contracted, 4,824 fuel bundles well fabricated and delivered to Wolsung Nuclear Power Plant. The process improvement, quality control, safety management, safeguards of nuclear materials and various kinds of audits have also been performed in the course for fuel manufacturing. Especially in 1993, the difficulties of the reduction of participating work-force were overcome by improving the manufacturing techniques, and raising the efficiency of the works, which ...
1994-03-01
Analysis of Elements in The Baltic Sea Sediment by Using Gamma Spectrometry
International Nuclear Information System (INIS)
We have done analysis of elements in the Baltic sea sediment by using gamma spectrometry in neutron activation analysis Goal of the analysis is to determine the rate of morsel elements which is contained in the Baltic sea sediment. Sample of the Baltic sea Sediment (IAEA-SED-1), Standard of Reference Material (SRM) 1646 Estuarine Sediment and Standard Ce, Fe, Sc, and Co are put into vial of capsule rabbit, then irradiated together for 30 minutes in rabbit facility Multi Purpose Reactor at power of 25 MW and then cooled for one week. Next sample, standard, and SRM which have irradiated, each is cut for 30 minutes using gamma spectrometer. Result of analysis of rate of elements Ce, Fe, Sc and Co in the baltic sea sediment successively equal to 141.20 ppm, 5.91 %, 14.88 ppm, and 19.59 ppm. Result of analysis in SRM Estuarine sediment successively equal to 96.60 ppm, 3.21 %, 10.25 ppm, and 9.63 ppm. Result of this analysis if compared to the value contained in SRM ...
2007-04-01
Accident analysis in research reactors
International Nuclear Information System (INIS)
Full text: Full text: The incomplete understanding of the complex mechanisms connected with the interaction between thermal-hydraulic and neutron kinetics still challenges the design and the operation of nuclear reactors and imposes the adoption of conservatism in the evaluation of safety limits. The recent availability of powerful computer and computational techniques together with the continuing increase in operational experience suggests the revisiting of those areas and the identification of design/operation requirements that can be relaxed. So far, almost all of the safety analyses of research reactors have been performed using conservative computational tools such as channel codes but, nowadays, the application of Best-Estimate (BE) methods constitutes a real necessity. The global aim of the current work is an attempt to apply the best-estimate system thermal-hydraulic code Relap5. For this purpose, the generic IAEA research reactor Benchmark problem is ...
2006-10-15
Energy Technology Data Exchange (ETDEWEB)
The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry activities in medical ...
1995-12-31
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
