WorldWideScience
1

I-131 labelled peanut lectin renal kinetics in cis-platin induced tubular toxicity in dogs  

International Nuclear Information System (INIS)

Quantitative I-131 labelled Peanut lectin (I-131-PNA) renal clearance was determined in dogs before and after a 5 day single cycle cis-platinum chemotherapy regimen (0.5mg/Kg/day). Results were statistically compared with E.R.P.F. (I-131-Hippuran), G.F.R. (Tc-99m-DTPA), and serum biochemistry and correlated with histopathology. I-131-PNA clearance was significantly reduced in all dogs 5 days after cessation of cis-platinum treatment (mean #DELTA#S% = 71.3%) and similar reductions in the gamma camera derived renogram peak were demonstrated (mean #DELTA#S% = 65.8%). E.R.P.F. was noted to drop by a minor degree (mean #DELTA#S% = 20.9%) post treatment. G.F.R. was diminished (mean #DELTA#S% = 46.6%) and serum creatinine elevated (mean #DELTA#S% = 42.7%) in all dogs compared to their ...

1985-06-02

3

Reversal of brain metabolic abnormalities following treatment of AIDS dementia complex with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine): a PET-FDG study  

International Nuclear Information System (INIS)

Brain glucose metabolism was evaluated in four patients with acquired immunodeficiency syndrome (AIDS) dementia complex using ["1"8F]fluorodeoxyglucose (FDG) and positron emission tomography (PET) scans at the beginning of therapy with 3'-azido-2',3'-dideoxythymidine (AZT, zidovudine), and later in the course of therapy. In two patients, baseline, large focal cortical abnormalities of glucose utilization were reversed during the course of therapy. In the other two patients, the initial PET study did not reveal pronounced focal alterations, while the post-treatment scans showed markedly increased cortical glucose metabolism. The improved cortical glucose utilization was accompanied in all patients by immunologic and neurologic improvement. PET-FDG studies can detect cortical metabolic abnormalities associated with AIDS dementia complex, and may be used to monitor the metabolic improvement in response to AZT treatment.

4

Transcatheter internal radiotherapy of hepatoma using radioactive iodized oil (I-131 Lipiodol)  

Energy Technology Data Exchange (ETDEWEB)

The lymphographic agent Lipiodol (iodized oil) has been found to localize and remain in tumor vessels. Based on this finding, we attempted transcatheter internal radiotherapy by radioactive iodized oil (I-131 tagged Lipiodol) prepared by isotopic exchange reaction. Transcatheter internal radiotherapy (TCIR) was attempted in twelve patients with inoperable hepatoma by infusing a therapeutic dose of I-131 Lipiodol (7.6 approx. 28.3 mCi/2.0 approx. 5.0 ml) via the hepatic artery. Serial changes of serum alpha-fetoprotein (AFP) levels and in the size of tumor on computed tomography (CT) were estimated to evaluate the therapeutic effect. Serum AFP levels decreased in 9 patients with initial elevated levels of serum AFP, although they were again elevated in three of them within four weeks. More than 50 % decrease in tumor size was observed in 6 patients (50 %). There were no serious complications. This ...

1988-04-01

5

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of ...

1989-08-15

6

Effect of application rates and media types on nitrogen and surfactant removal in trickling filters applied to the post-treatment of effluents from UASB reactors  

International Nuclear Information System (INIS)

Tricking filters are a very promising alternative for the post treatment of effluents from UASB reactors treating domestic sewage,especially in developing countries. Although a fair amount of information is already available regarding organic mater removal in this combined system, very little is known in relation to nitrogen and surfactant removal in trickling filters post-UASB reactors. Therefore, the purpose of this study was to evaluate and compare the effect evaluate and compare the effect of different application rates and packing media types on trickling filters applied to the post-treatment of effluents from UASB reactors, regarding the removal of ammonia nitrogen and surfactants. (Author)

7

Fatigue and Functional Impairment in Early-Stage Non-Small Cell Lung Cancer Survivors  

UK PubMed Central (United Kingdom)

ContextFatigue is the most common sequela among non-small cell lung cancer (NSCLC) survivors 1–6 years post-treatment and is associated with functional limitations.Full Text Available

2011-02-01

8

GAMMA GLOBULIN METABOLISM IN RABBITS DURING THE ANAMNESTIC RESPONSE.  

Science.gov (United States)

1. Gamma globulin metabolism and distribution were studied employing rabbit gamma globulin (RGG)I(131) 24 times in 13 control rabbits. Similar studies were performed before and during the ananmestic response in 4 rabbits previously sensitized with a polyvalent pneumococcal vaccine. 2. During the ananmestic response, gamma-globulin levels increased from 1.0 to 6.0 gm/100 ml, and the gamma-globulin pool increased from 0.7 to 4.7 gm/kg. There was no change in the intravascular-extravascular partition of gamma globulin. 3. Gamma globulin degradation increased from 0.06 to 0.33 gm/kg/day during the 28 days of the immunization period while gamma globulin synthesis increased even further to average 0.47 gm/kg/day. Following the attainment of elevated gamma globulin levels the fractional rate of RGG-I(131) turnover increased from 8.0 to 12.5 per cent/day. 4. No differences were noted in the metabolism of ...

1964-04-01

9

Ewing's sarcoma in childhood and adolescence  

International Nuclear Information System (INIS)

A review of main issues in diagnosing, complex treatment and prognosis of Ewing's sarcoma is presented. Current trend in chemotherapy, radiotherapy and surgery of the disease is discussed. Unfavourable prognosis is attributed to the systematic character of the disease, necessitating a complex therapeutic approach. Attempts to make an optimal combination of the three therapeutic methods in order to improve survival and reduce the rate of post-treatment complications are analyzed. 37 refs., 4 tabs. (author).

10

Age and body mass index-dependent relationship between correction of iron deficiency anemia and insulin resistance in non-diabetic premenopausal women  

International Nuclear Information System (INIS)

No prospective studies have evaluated the effects of correction of iron deficiency anemia on insulin resistance in non-diabetic premenopausal women with iron deficiency anemia. All patients were treated with oral iron preparations. Insulin resistance was calculated with the Homeostasis Model Assessment formula. All patients were dichotomized by the median for age and BMI to assess how the relationship between iron deficiency anemia and insulin resistance was affected by the age and BMI. Although the fasting glucose levels did not change meaningfully, statistically significant decreases were found in fasting insulin levels following anemia treatment both in the younger age (<40 years) (P=0.40) women and in the low BMI (27 kg/m) (P=0.22) subgroups but not in the older age (>= 40 years) and the high BMI (>-27Kg/m) subgroups. Post-treatment fasting insulin levels were positively correlated both with BMI (r=0.386, P=0.004) and ...

11

The operation status and prospect of radioisotope production facility in HANARO  

Energy Technology Data Exchange (ETDEWEB)

Researches and production of radio-isotopes, radio-pharmaceuticals and cold kits are carried out in the Radio-isotope Production Facility (RIPF). Four concrete hot cells in Bank-1 are to produce the Ir-192 source for NDT. Eleven lead hot cells in Bank-2 are to produce Ho-166, Cr-51, P-32/33, Tc-99m, Lu-177, Sr-90/Y-90 and W-188/Re-188 for research purpose. Six lead hot cells in Bank-3 are used for the production of I-131 for diagnosis and therapy of cancer in the hospital. A hot cell in Bank-3 is also utilized for the research of I-125 and Br-82. Four lead hot cells in Bank-4 are utilized for the production of Mo-99/Tc-99m generators since 2005. The major systems including the Heat and Ventilated Air Conditioning (HVAC) system and the air cleaning system such as charcoal and HEPA filter trains to filter the radioactive contaminants are in operation. So are the systems such as power supply and distribution system, UPS, fire protection system, ...

2008-11-15

12

Application of electro-Fenton oxidation for the detoxification of olive mill wastewater phenolic compounds  

Energy Technology Data Exchange (ETDEWEB)

Olive mill effluent (OMW) is an example of a wastewaters containing high concentrations of recalcitrant and toxic compounds which are polyphenolics of different molecular weight. It causes disposal problems because they contain powerful pollutants. Treatment and detoxification of phenolic fraction extracted from olive mill wastewaters as well as a synthetic phenolic mixture was investigated by electro-Fenton method. Results shows that this method is highly efficient in polymerising low molecular mass phenolics and removing a large amount of recalcitrant polyphenolic compounds. This treatment decreased 78% of the toxicity which sustained a good anaerobic post-treatment. (orig.)

2003-07-01

13

Anticipatory nausea and vomiting  

British Library Electronic Table of Contents (United Kingdom)

A commonly reported consequence of post-treatment nausea or vomiting is the development of anticipatory nausea and vomiting (ANV). In most published work, nausea is reported to occur before chemotherapy drugs are administered by approximately 20% of patients at any one chemotherapy cycle and by 25?30% of patients by their fourth chemotherapy cycle. Most studies in adult patients strongly support the view that the development of ANV involves elements of classical conditioning. The best method to avoid development of ANV is to adequately prevent both vomiting and nausea from the first exposure to chemotherapy. If anticipatory side effects develop, behavioral treatment techniques, such as systematic desensitization, have been shown effective. Benzodiazepines used in combination with behaviora...

2011-01-01

14

Scanning Electron Microscope Examination of Cotton Linters ...  

Science.gov (United States)

... TECHNICAL REPORT ARBRL-TR-02476 SCANNING ELECTRON MICROSCOPE ... SCANNING ELECTRON MICROSCOPE EXAMINATION OF ...

1983-03-01

15

Limiting factors and landscape connectivity: the American marten in the Rocky Mountains  

British Library Electronic Table of Contents (United Kingdom)

In mobile animals, movement behavior can maximize fitness by optimizing access to critical resources and minimizing risk of predation. We sought to evaluate several hypotheses regarding the effects of landscape structure on American marten foraging path selection in a landscape experiencing forest perforation by patchcut logging. We hypothesized that in the uncut pre-treatment landscape marten would choose foraging paths to maximize access to cover types that support the highest density of prey. In contrast, in the post-treatment landscapes we hypothesized marten would choose paths primarily to avoid crossing openings, and that this would limit their ability to optimally select paths to maximize foraging success. Our limiting factor analysis shows that different resistant models may be sup...

2011-01-01

16

Antitumor activity of platinum(II) complexes with histamine and radioiodinated histamine in a transplantable murine adenocarcinoma model  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Antitumor activity of the dichloroplatinum(II)-histamine complexes labeled with I-125 or I-131 was investigated in a transplantable murine adenocarcinoma (MA) model. Methods: The tumor model was obtained in C3H/W female mice after subcutaneous inoculation of the tumor cells derived from the mice bearing a mammary tumor of spontaneous origin. Antitumor activities of the platinum-histamine complexes were investigated in three independent experiments, which differed in applied doses of preparations (PtCl{sub 2}Hist, PtCl{sub 2}[{sup 125}I]Hist, PtCl{sub 2}[{sup 131}I]Hist, PtCl{sub 2}Hist/PtCl{sub 2}[{sup 125}I]Hist and PtCl{sub 2}Hist/PtCl{sub 2}[{sup 131}I]Hist), treatment schedules as well as stages of the disease progress in the animals used. Experiment 1 included long-term, multidose treatment with low single doses (treatment duration 31-32 days; 8-10 doses of ca. 0.25{center_dot}MTD{sub Pt} each). Experiment 2 included short-term, ...

2008-07-15

20

Particle-Sizing System for Scanning Electron Microscope ...  

Science.gov (United States)

... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...

1991-03-01

21

A bright field scanning transmission electron microscope (STEM ...  

Science.gov (United States)

A bright field scanning transmission electron microscope (STEM) micrograph showing a Wassonite grain in dark contrast. ...

22

The present state of nuclear medicine practice in Japan; A report of the 3rd nationwide survey in 1992  

Energy Technology Data Exchange (ETDEWEB)

The Subcommittee for Surveillance of Nuclear Medicine Practice has implemented a survey for actual nuclear medicine practice in Japan every 5 years. This article reports on the third survey implemented during a one-month period in June 1992. Questionnaires were sent to all 1256 facilities employing radiopharmaceuticals in routine practice, and 1162 (92.5%) answered. In vivo nuclear medicine examinations per day were performed in 6600 cases. SPECT accounted for 19.4%, as compared with 7.1% in the 1987 survey. According to organs, the frequency of examination for the cerebrospinal region was 3.2 and 2.2 times higher than that in the 1982 and 1987 surveys, respectively, whereas for the thyroid gland it was 0.6-fold and 0.7-fold that of these surveys. The proportion of bone scintigraphy was the highest (24.5%), followed by tumor scintigraphy (14.1%) and myocardial scintigraphy (11.9%). The frequency of myocardial and cerebral blood flow scintigraphy was dramatically increased as compared ...

1993-09-01

23

Technology of iodine-131 production and its application  

International Nuclear Information System (INIS)

Full text: Production: This radio iodine produced by three methods: 1) Wet method: The irradiated tellurium is dissolved in an oxidizing mixture which also converts iodine in to iodide. This is a chemical method and iodine that it produced with this method has low purity and efficiency. 2). Dry Method: The irradiated tellurium is dissolved in furnace (750 deg. C) with sublimation method and iodine absorbed in sodium solution . In this case we have more than 99.5 % purity and 80 % efficiency. We are using this type in Iran. 3) Fission fragment method: In this case the iodine separated from fission fragment directly and we have high purity (career free) and specific activity of iodine. Application: Iodine is a versatile tracer element. It is used to determine thyroid cancer metastases, and size, shape and activity of the thyroid gland. Critical organ of iodine is thyroid gland. One of the common diagnostic procedures for determining thyroid function therefore, is to measure the ...

24

Preparation of a high specific activity I-125 labeled styryl dye for leukocyte membrane labeling  

International Nuclear Information System (INIS)

The purpose of this work was to develop a high specific activity radioiodinated cell membrane probe for tracking lymphocytes in-vivo to replace the nucleus localizing, cytotoxic lipophilic chelates (In-111 oxine and Tc-99m HMPAO) currently used. Alkylation of parent dye 4-[2-[-N,N-didecylamino]phenyl]ethenyl pyridine with E-1-tributylstannyl-3-tosylpropene (prepared form E-1-tributylstannyl-1-propene-3-ol), gave a tributyltin precursor 1. Radiolabeled 3-[4-[2-[4-(N,N-didecylamino)phenyl]ethenyl]pyridino] E-[I-125]-1-iodopropene (2), was prepared from 1 using peracetic acid in acetonitrile/water. Labeling yields and specific activities achieved were 26% (#approx#2170 Ci/mmol), 40% (1220 Ci/mmol), and 55% (200 Ci/mmol) for nca, 0.4, and 2 nanomole carrier iodide runs respectively. Canine mixed leukocytes (0.5-1.0 x 10"8 cells) were labeled with 2 (67% and 42% yields for 200 Ci/mol and 1220 Ci/mmol preparations) and showed blood clearance similar to In 111 oxine. Radioiodinated styryl dye ...

1994-08-21

25

School refusal and anxiety in adolescence: Non-randomized trial of a developmentally sensitive cognitive behavioral therapy.  

Science.gov (United States)

The main objectives were to evaluate efficacy and acceptability of a developmentally sensitive cognitive behavioral therapy for anxiety-based school refusal in adolescence. Twenty school-refusing adolescents meeting DSM-IV anxiety disorder criteria participated in a non-randomized trial, together with parents and school staff. Outcome was assessed at post-treatment and 2-month follow-up. Treated adolescents showed significant and maintained improvements across primary outcome variables (school attendance; school-related fear; anxiety), with medium to large effect sizes. Half of the adolescents were free of any anxiety disorder at follow-up. Additional improvements were observed across secondary outcome variables (depression; overall functioning; adolescent and parent self-efficacy). The treatment was rated as acceptable by adolescents, parents, and school staff, which may help explain the very low attrition rate. Social anxiety disorder was the most common disorder ...

2011-04-28

26

Operant behavior of rats exposed to lead before or after weaning  

Energy Technology Data Exchange (ETDEWEB)

Rats were exposed to lead (Pb) before or after weaning. For preweaning exposures, nursing dams received 0.2% Pb acetate(1090 ppm Pb) in drinking water. Offspring treated after weaning consumed the same concentration. Tapwater served as the control fluid. Pre-post treatments were distributed among four experimental groups of 10 rats each: tap water-tap water, Pb-tap water, tap water-Pb, Pb-Pb. Operant behavior training began on Postnatal Day 58. Animals performed on a multiple reinforcement schedule of food presentation consisting of fixed-interval, fixed-ratio, and time out components.Statistical analyses of experimental sessions 4 to 11 (Postnatal Days 72 to 79) revealed that postweaning exposure significantly lengthened the median interval (interresponse time) between consecutive responses on both the interval and ratio schedules. Preweaning exposure alone tended to produce a shortening of the median interresponse time. Other performance ...

1982-01-01

27

Effect of clindamycin treatment on vaginal inflammatory markers in pregnant women with bacterial vaginosis and a positive fetal fibronectin test  

British Library Electronic Table of Contents (United Kingdom)

Objective To compare the levels of interleukin (IL)-1?, IL-6, and matrix metalloproteinase (MMP)-8 in the vaginal secretions of pregnant women with a positive fetal fibronectin (fFN) test result with or without asymptomatic bacterial vaginosis (BV) before and after treatment with oral clindamycin. Methods A prospective cohort study was conducted among 43 pregnant women with a positive fFN test result. All patients were treated with clindamycin, and the pre- and post-treatment levels of IL-1?, IL-6, and MMP-8 were compared. Results Before treatment, levels of IL-1? and MMP-8 were significantly higher in women with BV compared with women without BV (P<0.05). Vaginal levels of IL-1? and IL-6, but not MMP-8, decreased after treatment in pregnant women with BV. Conclusions The inability of clin...

2009-01-01

28

Anti-corrosive properties of an electropolymerized polymer coating on a shape memory alloy surface  

Energy Technology Data Exchange (ETDEWEB)

Acrylonitrile electropolymerization (in an aprotic and anhydrous medium) has been used as a way to build thin, homogeneous and covering polyacrylonitrile layers grafted on the surface of usual metals and specially on copper-based shape memory alloy: Cu-Zn-Al. The results of the study first confirm the possibility of grafting thin and covering polyacrylonitrile layers on Cu-Zn-Al surface. The morphology of the films however is influenced by the geometry of the polycristalline structure of the alloy and its superficial defects. Samples obtained after grafting polyacrylonitrile films were submitted to corrosion tests based on Electrochemical Impedance Spectroscopy (EIS) measurements in a NaCl/H{sub 2}O medium. Results show that some post-treatments of the grafted films are necessary to improve their protective role, while preserving the strong interfacial bondings. Actually, thermal and mechanical cycling of the shape memory alloy covered by electropolymerized ...

1996-01-01

29

Motion compensation with a scanned ion beam: a technical feasibility study  

UK PubMed Central (United Kingdom)

BackgroundIntrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target...Full Text Available

31

Development of New Ground Inspection Techniques for the ...  

Science.gov (United States)

Integration of Eddy Current probes with MAUS scanning system has been demonstrated to produce scan rates of 36 sqft/hour. System will be designed to ...

32

Bone scanning in Ewing's sarcoma  

International Nuclear Information System (INIS)

In eight patients with Ewing's sarcoma bone scans were performed using "9"9"mTc-MDP. This procedure rendered possible the diagnosis of clinically or radiologically silent metastases. (orig.).

33

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples  

Science.gov (United States)

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to

2003-01-01

34

Versatile gamma scanning system  

International Nuclear Information System (INIS)

(Feb 1972). United States Swinth, KL Weber, JW San Francisco, Calif.

38

Is there still a place for bone scanning in Ewing's sarcoma: concise communication  

International Nuclear Information System (INIS)

In this retrospective study, 28 cases of Ewing's sarcoma are reviewed for the onset of metastasis. Bone scans demonstrated bone metastasis in three out of 28 patients at presentation. Of the 22 patients free of metastases at presentation, ten subsequently developed bone metastases. In six of these patients, the bone scan was the earliest demonstrator of metastatic disease. Bone scans are recommended at presentation and periodically during follow-up.

41

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

43

An evaluation of low-dose single-slice helical CT in pulmonary CT scan  

International Nuclear Information System (INIS)

Objective: To investigate the feasibility of low-dose single-slice helical CT in pulmonary CT scan and evaluate the clinical application. Methods: Thirteen cases were selected out of 132 cases, in which low-dose (50mAs) single-slice helical CT scan of chest was performed. This set of cases included 7 cases of multiple metastatic nodules; 3 of solitary pulmonary, nodule; and 3 of pulmonary patchy lesions. Regular dose (170mAs) CT scan was also performed on all those patients. The regular dose and low dose CT scan were compared on sensitivity of detecting the lesions; the performance in demonstrating the details of the abnormalities; and the capability of revealing the segmental bronchi as well. Results: The same number and size of the pulmonary nodules were revealed with scan modalities loaded with different doses. No significant difference in demonstrating the details of the nodules ...

2006-04-01

44

"9"9"mTechnetium-heat damaged erythrocyte spleen scan  

International Nuclear Information System (INIS)

"9"9"mTechnetium -heat damaged erythrocyte were used as spleen scanning agents in 12 patients from July, 1985 to April, 1986. We used this scan to evaluate situs inversus, asplenia, accessory spleen, hypersplenism, splenic infarction, tumor staging and evaluation of therapy, especially when the "9"9"mTc-tin colloid scans were not definite for diagnosis. The techniques applied to these scans were in vivo/in vitro-labeling method and heating-method to damage the erythrocytes. Liver-to-spleen uptake ratios were increased upto 100:1 and interference from the left lobe of the liver was eliminated. These scans were helpful to evaluate the spleen. (Author).

45

Ultrasmall spot size scanning laser ophthalmoscopy  

UK PubMed Central (United Kingdom)

An ultrasmall spot size scanning laser ophthalmoscope has been developed that employs an annular aberration-corrected incident beam to increase the effective numerical aperture of the eye thereby reducing...Full Text Available

46

Simple device for scanning image  

CERN Document Server

The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.

2002-01-01

47

Role of Quantitative Bone Scanning in the Assessment of Bone Turnover in Patients With Charcot Foot  

UK PubMed Central (United Kingdom)

OBJECTIVETo assess the new quantitative bone scan parameters as markers of Charcot neuroosteoarthropathy (CNO) activity.RESEARCH DESIGN AND METHODSForty-two...Full Text Available

2010-02-01

48

New retinal imaging for the visualization and analysis of vitreoretinal interface (VRI) by short-wavelength scanning laser ophthalmoscope (swSLO)  

UK PubMed Central (United Kingdom)

Background:The purpose of the study was to evaluate vitreoretinal interface (VRI) alteration with a short-wavelength scanning laser ophthalmoscope (swSLO), the Nidek F-10, and compare...Full Text Available

2011-01-01

49

New Biomarkers Probing Depth of Cell Senescence Assessed by Laser Scanning Cytometry  

UK PubMed Central (United Kingdom)

The imaging analytical capabilities of laser scanning cytometer (LSC) have been used to assess morphological features considered to be typical of the senescent phenotype. The characteristic “flattening”...Full Text Available

2010-11-01

53

Patterns of gallium-67 scintigraphy in patients with acquired immunodeficiency syndrome and the AIDS related complex  

Energy Technology Data Exchange (ETDEWEB)

Thirty-two patients with AIDS related complex (ARC) or acquired immunodeficiency syndrome (AIDS) underwent /sup 67/Ga scans as part of their evaluation. Three patterns of /sup 67/Ga biodistribution were found: lymph node uptake alone; diffuse pulmonary uptake; normal scan. Gallium-67 scans were useful in identifying clinically occult Pneumocystis carinii pneumonia in seven of 15 patients with ARC who were asymptomatic and had normal chest radiographs. Gallium scans are a useful ancillary procedure in the evaluation of patients with ARC or AIDS.

1987-07-01

54

Environmental scanning electron microscopy  

Energy Technology Data Exchange (ETDEWEB)

The ElectroScan environmental scanning electron microscope (ESEM) is one of the most exciting new developments in the field of Electron Microscopy. The ESEM differs from conventional Scanning Electron Microscopes (SEM) by being able to examine materials including liquids and oils in their natural state with no prior sample preparation. Accessory equipment, cooling, heating and manipulating devices allow the manipulation of samples thus making it possible for the first time to image dynamic processes such as wetting, drying, absorption, corrosion, melting, crystallisation, curing and fracturing at high magnification. Papers concerning the historical development of the ESEM are given in a bibliography at the end of this paper. 24 refs., 18 figs.

1994-12-31

55

Burned Timber Canyon  

Science.gov (United States)

The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....

57

Pteromalus puparum venom impairs host cellular immune responses by decreasing expression of its scavenger receptor gene.  

Science.gov (United States)

Insect host/parasitoid interactions are co-evolved systems in which host defenses are balanced by parasitoid mechanisms to disable or hide from host immune effectors. Although there is a rich literature on these systems, parasitoid immune-disabling mechanisms have not been fully elucidated. Here we report on a newly discovered immune-disabling mechanism in the Pieris rapae/Pteromalus puparum host/parasitoid system. Because venom injections and parasitization suppresses host phagocytosis, we turned attention to the P. rapae scavenger receptor (Pr-SR), posing the hypothesis that P. puparum venom suppresses expression of the host Pr-SR gene. To test our hypothesis, we cloned a full-length cDNA of the Pr-SR. Multiple sequences alignment showed the deduced amino acid sequence of Pr-SR is similar to scavenger receptors of other lepidopterans. Bacterial and bead injections induced Pr-SR mRNA and protein expression, which peaked at 4h post-bead injection. Venom injection inhibited Pr-SR ...

2011-07-22

58

Peak "1"4CO_2 excretion, symptoms and eradication of H.Pylori (HP) in patients with duodenal ulcer (DU)  

International Nuclear Information System (INIS)

Full text: Many factors including drug efficacy, compliance and antibiotic resistance may influence HP eradication rates. The "1"4C urea breath test is a sensitive method of confirming HP colonisation and eradication. The aim was to study the relationships between the peak "1"4CO_2 counts on the breath test prior to treatment, smoking and HP eradication, and to assess if persistent or recurrent symptoms implied failure of eradication. 117 patients with DU and HP colonisation proved on biopsy or rapid urease test who underwent "1"4C urea breath tests at least one month after eradication treatment was ceased were studied (69 male, 48 female, mean age 41, range 26-87 y). Questionnaire assessment of treatment regimen, smoking history and dyspeptic symptoms was made at the time of the breath test. A sub-group of 43 patients who had pre- and post-treatment breath tests was studied to assess if high peak "1"4CO_2 counts on the pre-treatment breath test related to ...

1997-12-01

59

Oxide induced corrosion on the welded stainless steels SS 2352 and 2353; Oxidbetingad korrosion i svetsar hos de rostfria staalen SS 2352 och 2353  

Energy Technology Data Exchange (ETDEWEB)

The pitting corrosion properties have been investigated in welded and unwelded condition by polarization tests in sodium chloride solutions. The two steels were TIG welded without adding welding material and as shielding on the bottom side argon gas containing 2, 26 or 99 ppm oxygen was used. In some tests low breakthrough potentials were received, without discovering any pitting corrosion in the specimen surfaces. The unwelded SS 2352 steel had a critical (lowest) pitting temperature (CPT) of 5 degrees C in the more concentrated solution. For the same steel with weld pitting corrosion was obtained at 5 degrees C, which was the lowest temperature for the tests. Thus the CPT value was lower than 5 degrees C, but by looking at the pitting corrosion potentials the following conclusion could be drawn: Welding with higher oxygen content in the shielding gas implied lower pitting corrosion resistance. For the SS 2353 steel the CPT values were 25 and 27.5 degrees C for material without weld, ...

1991-09-16

60

Inguino-scrotal hernia detection in the early phase of a bone scan  

International Nuclear Information System (INIS)

A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd

1999-11-01

61

Gamma scanning of FBTR fuel pins  

International Nuclear Information System (INIS)

This paper presents the results obtained in the gamma scanning of two fuel pins from the bent subassembly of the fast breeder test reactor (FBTR) using a segmented gamma scanning system employing segment correlation developed for the assay of glove box solid waste. In addition to the actinide profiles, the paper also discusses the fission products and clad activation product profiles and tries to correlate the experimental values of the latter with computed values. (author). 4 refs., 1 fig., 1 tab.

62

Computer analysis and control for nondestructive gamma scanning of LMFBR fuel pins  

International Nuclear Information System (INIS)

A program to modernize existing computer control and data analysis in a precision gamma-scanning system is described. This involves interfacing a new computer-based multichannel analyzer to existing equipment through a CAMAC system with an intelligent crate controller and writing software for scan control and data reduction. Both hardware and software requirements are discussed. 6 figures.

63

Brain and bone scans in primary Ewing's sarcoma of the petrous bone: case report  

International Nuclear Information System (INIS)

The authors present a case in which primary Ewing's sarcoma of the right petrous pyramid in a 9-year-old girl showed no uptake on a /sup 99m/Tc-pertechnetate nuclide angiogram. Intense uptake was present on a /sup 99m/Tc-polyphosphate bone scan, but a static brain scan was only minimally abnormal. The diagnosis and treatment of Ewing's sarcoma are reviewed.

64

The usefulness of CBF brain SPECT in forensic medicine: the civil law codes cases. A description of four cases  

International Nuclear Information System (INIS)

The aim of this report was to assess the usefulness of cerebral blood flow (CBF) scanning utilising the SPECT technique in forensic medicine cases in the area of civil law cases. CBF SPECT scanning was performed in four patients utilising "9"9"mTc-ECD and a triple-head gammacamera. In the analysis both the asymmetry index and cerebellar normalisation were applied. Reference values were obtained by studying 30 healthy volunteers. In those cases CBF SPECT scanning played an important role in forensic argument. It influenced the sentence and the amount of financial compensation. CBF SPECT scanning may provide valuable information in forensic medicine argument in civil law cases, but only when taken together with psychometric tests and other neuroimaging methods (CT, MRI). The value of CBF SPECT scanning alone may be limited in judicial proceedings. (author)

65

Applicator reconstruction and applicator shifts in 3D MR-based PDR brachytherapy of cervical cancer  

British Library Electronic Table of Contents (United Kingdom)

Purpose To evaluate the methods of applicator reconstruction in 3D MR-based planning for brachytherapy of cervical cancer, and to investigate applicator shifts and changes in DVH parameters during PDR treatment. Methods For each application MR scans with applicator in situ were made: three T2-weighted (4.5mm slices) Turbo Spin Echo (TSE) scans and a balanced Steady State Free Precession scan (1.5mm). Three observers tested two applicator reconstruction methods: (A) directly on the bSSFP scan and (B) on a resampled combination of the three T2-weighted scans. For 10 patients MR imaging was repeated on the second day of each PDR fraction to determine applicator shifts and changes in DVH parameters. Results For both applicator reconstruction methods the interobserver variation for the DVH para...

2009-01-01

66

Aggressive Ewing's sarcoma appearing as a cold lesion on bone scan  

International Nuclear Information System (INIS)

Ewing's sarcoma classically presents as a hot spot on bone scan as a result of increased vascularity of the tumor and new bone formation. Purpose We report and analyze an uncommon pattern of a 'cold' lesion in Ewing's sarcoma on bone scan and its pathophysiologic significance. Case report A 15-year-old boy complaining of thigh pain. CT scan evoked Ewing's sarcoma or osteitis. MRI evoked chronic osteitis. Scintigraphy showed a fairly intense and heterogeneous uptake on the femoral lesion and no abnormal uptake elsewhere. Biopsy showed none pathologic pattern. Three months later, a second biopsy concluded to Ewing's sarcoma. Bone scan showed a larger lesion with peripheral intense uptake centered by enlarged 'cold' area in the left femoral diaphysis and no evident bone metastasis. The patient underwent chemotherapy and surgery. Three months later, bone scan showed extensive skeletal ...

2009-10-01

67

Radionuclide liver and bone scanning in the evaluation of patients with endometrial carcinoma  

International Nuclear Information System (INIS)

Staging bone scans or skeletal surveys were obtained of 97 patients with endometrial carcinoma. Of the 77 patients with Stage I or II disease, no metastases were identified at staging. Three patients in the entire series demonstrated bony metastases; all of these metastases were detectable by radionuclide bone scan and radiographic bone survey. Eighty-nine patients were examined with radionuclide liver/spleen scanning at the time of staging. Four of the 89 initial scans were interpreted as demonstrating hepatocellular disease, and all four patients had abnormal liver function studies. Only one patient demonstrated a possible hepatic metastasis at initial diagnosis. This patient also had abnormal liver function studies. Based on these results, bone surveys and radionuclide bone scans are not indicated as screening procedures in endometrial carcinoma. It is suggested that screening ...

68

Detection of abnormalities in febrile AIDS patients with In-111-labeled leukocyte and Ga-67 scintigraphy  

International Nuclear Information System (INIS)

Thirty-six patients with acquired immunodeficiency syndrome (AIDS), who were febrile but without localizing signs, underwent indium-111 leukocyte scintigraphy 24 hours after injection of labeled white blood cells (WBCs) and were restudied 48 hours after injection of gallium-67 citrate. Fifty-six abnormalities were identified as possible sources of the fever; 27 were confirmed with biopsy. Of these 27, 15 were identified only on In-111 WBC scans (including colitis, sinusitis, and focal bacterial pneumonia); six, only on Ga-67 scans (predominantly Pneumocystis carinii pneumonia and lymphadenopathy); and six, on both studies (predominantly pulmonary lesions). In-111 WBC scanning revealed 21 of 27 abnormalities (78%) and gallium scanning, 12 of 27 (44%). If only one scintigraphic study has been performed, particularly with Ga-67, a significant number of lesions would not have been detected. The authors ...

69

CT diagnosis of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate contrast-enhanced CT scan in the diagnosis of intrahepatic cholangiocarcinoma by correlating the CT appearance with pathologic specimens. Materials and methods: Twenty-eight patients with pathologically proven intrahepatic cholangiocarcinoma were examined. Unenhanced abdominal CT study were performed in 28 patients; conventional contrast-enhanced CT in 27 patients. Enhanced CT scan including fast injection, fast scan and delayed scan at the largest section of the lesion was done in 7 patients. Contiguous 10 mm CT scans of the surgical specimens were also obtained in 8 patients. The preoperative and specimen CT scans in these 8 patients were compared with the corresponding pathological sections. A total of 103 areas of the pathological sections was compared with the CT appearances. Results: All lesions contained areas of delayed contrast ...

70

Efficacy and safety of total dose infusion of low molecular weight iron dextran in the treatment of iron deficiency anemia during pregnancy  

International Nuclear Information System (INIS)

To determine the efficacy and safety of Total Dose Infusion (TDI) of low molecular weight iron dextran for the treatment of iron deficiency anemia compared to oral iron replacement during pregnancy through improvement in hemoglobin (Hb) after intervention. Non-randomized control trial. A group of 100 pregnant women with gestational age greater than 12 weeks with confirmed diagnosis of iron deficiency anemia attending the antenatal clinics were enrolled in this study. Total dose iron infusion of low molecular iron dextran was given to these patients after calculating iron deficit, in a monitored in-patient setting. Control comprised of a second group of 50 pregnant females matched for age, parity and baseline hemoglobin, tolerant to oral iron supplementation (ferrous sulphate 200 mg three times a day) attending the antenatal clinics during the same period. Post-treatment hemoglobin levels of study group as well as the oral control group were determined between 3 to ...

2008-07-01

71

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

72

Role of nuclear medicine bone scans in evaluating pain in athletic injuries  

Energy Technology Data Exchange (ETDEWEB)

The utilization of nuclear medicine bone scanning examinations early in the diagnostic process allows physicians to render prompt and correct treatment in urgent or difficult athletic cases. Bone scanning should be performed for athletic injuries whenever (1) x-rays are normal but bone or joint pain persists; (2) x-rays are positive but it cannot be determined if the findings are acute or chronic; (3) soft-tissue injuries present and x-rays are not useful; and (4) bone pain or joint impairment present without a history of trauma.89 references.

1987-10-01

73

Bone scanning in Ewing's sarcoma  

International Nuclear Information System (INIS)

This is a retrospective analysis of bone scans in 72 patients with Ewing's sarcoma. Sites of primary disease were found to be evenly distributed among the axial skeleton and the proximal and distal extremities. Primary disease sites in the axial skeleton were more frequently associated with metastases. Fifty-three of these patients had their first scans done at presentation; among them, 25 were found to have metastases. Unsuspected metastases were picked up in 28 of all the patients. Metastases at presentation were seen to be associated with a poorer prognosis.

74

Size determination of Acipenser ruthenus spermatozoa in different types of electron microscopy  

British Library Electronic Table of Contents (United Kingdom)

In this study three types of scanning electron microscopes were used for the size determination of spermatozoa of sterlet Acipenser ruthenus - high vacuum scanning electron microscope (SEM, JEOL 6300), environmental scanning electron microscope (ESEM, Quanta 200 FEG), field emission scanning electron microscope (FESEM, JEOL 7401F) with cryoattachment Alto 2500 (Gatan) and transmission electron microscope (TEM, JEOL 1010). The use of particular microscopes was tied with different specimen preparation techniques. The aim of this study was to evaluate to what degree the type of used electron microscope can influence the size of different parts of spermatozoa. For high vacuum SEM the specimen was prepared using two slightly different procedures. After chemical fixation with 2.5% glutaraldehyde...

2010-01-01

75

Scanning Electron Microscopy of Sarcophagid (Diptera) Larvae Recovered from a Case of Human Cutaneous Myiasis  

Science.gov (United States)

... point dried and mounted on aluminum stubs using colloidal silver paste. Mounted specimens were observed and photographed using ... ...

76

New Image - ONLY - Scan to PDF - NASA Technical Reports Server  

Science.gov (United States)

Aluminum electrolytic capacitors are presently not allowed ..... specified for commercial aluminum electrolytic capacitors of similar rating. ...

77

New Image - ONLY - Scan to PDF - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Variations,of-the ,rudder pedel force with.indicated airspeed are shown in figure 16 for the six vertical-tail configurations. -tested. ...

78

New Image - ONLY - Scan to PDF - NASA Technical Report Server (NTRS)  

Science.gov (United States)

ratio 2 with NACA 0005-63 thickness distribution in streamwise planes, and twisted and cambered for a trapezoidal span load distribution has ...

79

High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry  

CERN Document Server

In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori knowledge.

2004-01-01

80

Habitat Selection by Mountain Plovers in Shortgrass Steppe  

Science.gov (United States)

... the area covered by the point-count grid, stopping approximately every 100 m, stepping away from the vehicle, and scanning with binoculars for mountain plovers. Once ... ...

81

FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...  

Science.gov (United States)

was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...

83

Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning  

International Nuclear Information System (INIS)

The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).

84

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This work describes scanning in charged-particle microscopes, which is applied both in the artificial image generator and the DCIC ...

2010-01-01

85

Voronoi distance based prospective space-time scans for point data sets: a dengue fever cluster analysis in a southeast Brazilian town  

UK PubMed Central (United Kingdom)

BackgroundThe Prospective Space-Time scan statistic (PST) is widely used for the evaluation of space-time clusters of point event data. Usually a window of cylindrical shape is employed,...Full Text Available

86

Scanning tip microwave near-field microscope  

Energy Technology Data Exchange (ETDEWEB)

A near-field microscope which operates in the rf/microwave frequency range is described. In this microscope, a scanning tunneling microscope (STM)-like tip rather than an aperture is used as a point-like evanescent field emitter. A spatial resolution of {approximately}5 {mu}m ({approximately}{lambda}/100000) is achieved in the current version. The design of the microscope as well as the principal factors which affect its performance are discussed. {copyright} {ital 1996 American Institute of Physics.}

1996-06-01

87

Practical MRI atlas of neonatal brain development  

International Nuclear Information System (INIS)

This book is an anatomical reference for cranial magnetic resonance imaging (MRI) studies in neonates and infants. It contains 122 clear, sharp MRI scans and drawings showing changes in the normal appearance of the brain and skull during development. Sections of the atlas depict the major processes of maturation: brain myelination, development of the corpus callosum, development of the cranial bone marrow, and iron deposition in the brain. High-quality scans illustrate how these changes appear on magnetic resonance images during various stages of development.

88

Paraquat-induced pulmonary lesions : HRCT findings in long-term follow-up : a case report  

International Nuclear Information System (INIS)

We illustrate serial HRCT findings over a 16-month period in a 35-year-old woman who had ingested paraquat. Initial areas of ground-glass opacity changed into areas of multiple air cysts on follow up scan obtained five months after ingestion. A further follow-up scan obtained 16 months after ingestion showed improvement, with increased lung volume and normalized lung architecture.

1997-03-01

89

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

90

Isolated dextrogastria: report of two cases  

International Nuclear Information System (INIS)

Isolated situs inversus of the stomach with otherwise normal position of the thoracic and abdominal viscera is an extremely rare anomaly occurring in two distinct forms. Because of its close relationship to the liver, the right-sided stomach may produce interesting and confusing changes in the liver scan. Two cases illustrate the radiologic features of the two principal types of isolated congenital dextrogastria and the effect of one type on the liver scan.

91

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system  

International Nuclear Information System (INIS)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).

92

Incidental orbital calcifications on computed tomography scans; Calcificacoes orbitarias incidentais na tomografia computadorizada  

Energy Technology Data Exchange (ETDEWEB)

We retrospectively studied the computed tomography scans of the orbit in 75 patients in order to identify the presence of incidental calcifications (scleral and trochlear apparatus calcifications.). These imaging findings should integrate the vast list of differential diagnosis of orbital calcifications, as they may help radiologists to distinguish these calcifications from orbital foreign bodies. (author)

2001-02-01

93

IMEF gamma scanning system  

International Nuclear Information System (INIS)

The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

1989-09-10

94

Development of heavy-ion irradiation technique for single-event in semiconductor devices  

Energy Technology Data Exchange (ETDEWEB)

Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)

1997-03-01

95

Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle  

Energy Technology Data Exchange (ETDEWEB)

The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.

1988-10-13

96

Bone scintigraphy in Ewing's sarcoma during and after treatment - prognostic information from the primary tumor site  

International Nuclear Information System (INIS)

A bone scan can be negative in Ewing's sarcoma. The bone scan during and after treatment can give prognostic information on the primary tumor site: A persisting hot spot strongly suggests the presence of local malignancy, while a hot spot becomming negative points to local cure of Ewing's sarcoma. (orig.).

97

Localization of islet cell tumors by dynamic CT: comparison with plain CT, arteriography, sonography, and venous sampling  

Energy Technology Data Exchange (ETDEWEB)

Ten patients with suspected islet cell tumors (seven with possible gastrinomas, three with insulinomas) underwent diagnostic evaluation with dynamic CT scanning, routine CT scanning, angiography, and sonography. Venous sampling was also performed in selected instances. Nine sites of gastrinoma and three insulinomas were confirmed surgically in eight patients. Two patients had negative surgical explorations. Routine CT demonstrated five of the nine gastrinomas and one of two insulinomas. Angiography was positive in six of nine gastrinomas and all three insulinomas. Sonography showed only two of the nine gastrinomas and two of the three insulinomas. Dynamic CT scanning demonstrated three additional lesions (two gastrinomas, on insulinoma) not visible on routine CT scanning. Although most of these lesions were visible arteriographically, dynamic CT scans at the appropriate level ...

1984-09-01

98

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel ...

99

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning measurements on 31 spent PWR fuel ...

2007-03-15

100

The surface topography of the choroid plexus. Environmental, low and high vacuum scanning electron microscopy  

British Library Electronic Table of Contents (United Kingdom)

Environmental scanning electron microscopy (ESEM) allows the examination of hydrated and dried specimens without a conductive metal coating which could be advantageous in the imaging of biological and medical objects. The aim of this study was to assess the performance and benefits of wet-mode and low vacuum ESEM in comparison to high vacuum scanning electron microscopy (SEM) using the choroid plexus of chicken embryos as a model, an organ of the brain involved in the formation of cerebrospinal fluid in vertebrates. Specimens were fixed with or without heavy metals and examined directly or after critical point drying with or without metal coating. For wet mode ESEM freshly excised specimens without any pre-treatment were also examined. Conventional high vacuum SEM revealed the characterist...

2011-01-01

101

Numerical modeling of scanning laser-induced melting, vaporization and resolidification in metals subjected to step heat flux input  

Energy Technology Data Exchange (ETDEWEB)

We present a 1-D heat transfer, melting, vaporization and resolidification model describing the interaction of a scanning continuous-wave laser with a metal surface wherein the beam power is constant. A physical model based on the Stefan problem is developed with appropriate boundary conditions. The effects of processing parameters on process variables are investigated numerically by varying beam diameters, scan speeds and substrate temperatures for Nickel. Relations are derived for the times to initiate melting, to initiate vaporization, to reach maximum melting depth, for melting-resolidification, and for maximum melting and vaporization depths. Surface temperatures are compared with approximate closed form solutions. (Author)

2004-09-01

102

Local thermal property analysis by scanning thermal microscopy of an ultrafine-grained copper surface layer produced by surface mechanical attrition treatment  

International Nuclear Information System (INIS)

Scanning thermal microscopy (SThM) was used to map thermal conductivity images in an ultrafine-grained copper surface layer produced by surface mechanical attrition treatment (SMAT). It is found that the deformed surface layer shows different thermal conductivities that strongly depend on the grain size of the microstructure: the thermal conductivity of the nanostructured surface layer decreases obviously when compared with that of the coarse-grained matrix of the sample. The role of the grain boundaries in thermal conduction is analyzed in correlation with the heat conduction mechanism in pure metal. A theoretical approach, based on this investigation, was used to calculate the heat flow from the probe tip to the sample and then estimate the thermal conductivities at different scanning positions. Experimental results and theoretical calculation demonstrate that SThM can be used as a tool for the thermal property and microstructural analysis of ...

2006-06-15

103

Interpretation of gamma-scanning data from the ORR demonstration elements  

Energy Technology Data Exchange (ETDEWEB)

The HEU and LEU fuel elements used in the ORR whole-core demonstration were gamma-scanned to determine the axial distribution of the {sup 140}La and {sup 137}Cs activities. Analysis of this data is now complete. From the {sup 140}La activity distributions cycle-averaged powers were determined while the {sup 137}Cs data provided a measure of the final {sup 235}U burnup in the fuel elements. A method for calculating correction factors for activity gradients transverse to the fuel element axis is presented and is applied to the first mixed core used in the demonstration during the gradual transition to an all LEU core. Results based on the gamma-scanning of the LEU fuel followers are also presented. Improved burnup calculations against which the experimental results are to be compared are now in progress. 7 refs., 21 figs., 3 tabs.

1989-01-01

104

High speed inverted optical-resolution photoacoustic microscopy  

Science.gov (United States)

Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.

2011-02-01

105

Using Regulatory and Epistatic Networks to Extend the Findings of a Genome Scan: Identifying the Gene Drivers of Pigmentation in Merino Sheep  

UK PubMed Central (United Kingdom)

Extending genome wide association analysis by the inclusion of gene expression data may assist in the dissection of complex traits. We examined piebald, a pigmentation phenotype in both human and Merino...Full Text Available

106

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

107

The Prevalence of Concha Bullosa and Nasal Septal Deviation and Their Relationship to Maxillary Sinusitis by Volumetric Tomography  

UK PubMed Central (United Kingdom)

The objective of this study was to determine the prevalence of concha bullosa and nasal septal deviation and their potential relationships to maxillary sinusitis. 883 CT scans taken at Creighton University...Full Text Available

2010-01-01

108

TO: All GCN Notice recipients RE  

Science.gov (United States)

These sky images are scanned for point sources above a specified ... The threshold criteria are: a) Gold: >4 sigma in both the Soft AND Hard bands. b) Silver: ... Filtering: Currently, there is no plan for filtering within the GCN based ...

110

Structure of first- and second-stage mineralized elements in teeth of the sea urchin Lytechinus variegatus  

UK PubMed Central (United Kingdom)

Microstructure of the teeth of the sea urchin Lytechinus variegatus was investigated using optical microscopy, SEM (scanning electron microscopy) and SIMS (secondary ion mass...Full Text Available

2009-12-01

111

Spacecraft and Instruments - NASA  

Science.gov (United States)

Aerosol Polarimetry Sensor (APS) + Continuous along-track scanning ... side of the spacecraft and faces outward, measures the intensity of incoming solar ... on a larger rocket, and faced slightly different conditions in spaceinto Glory wasn't ...

112

PrognoScan: a new database for meta-analysis of the prognostic value of genes  

UK PubMed Central (United Kingdom)

BackgroundIn cancer research, the association between a gene and clinical outcome suggests the underlying etiology of the disease and consequently can motivate further studies. The...Full Text Available

113

Prevalence of Renal Artery and Kidney Abnormalities by Computed Tomography among Healthy Adults  

UK PubMed Central (United Kingdom)

Background and objectives: Management of incidental renal artery and kidney abnormalities in patients undergoing computed tomography scans is a clinical challenge because their frequency in healthy...Full Text Available

2010-03-01

114

Performance of a modified two-dimensional gamma scan system in spent fuel pin studies  

International Nuclear Information System (INIS)

This work assesses the performance of a modified two-dimensional gamma scan system in spent fuel pin studies. The techniques for a two-dimensional gamma scan studied have been developed at the Hot Cell of Institute of Nuclear Energy Research (INER). Samples are acquired from the spent fuel pin, TPC-SP-C1, which was irradiated in a commercial reactor core (the first of its kind in Taiwan) for 2 years and then deposited in a cooling pool for 10 years. The spent fuel pin was then transferred into INER for further examination. The gamma scanning system was driven by a step motor which had an accuracy within 0.1 mm in both X-Y directions. Data obtained from this system are presented in both an isotopic distribution and contour plot. Results in this study closely correspond to those in other investigations, thereby confirming the effectiveness of this modified system. (author)

1999-11-01

115

Performance characterization of a volumetric breast ultrasound scanner  

Science.gov (United States)

The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good ...

2007-03-01

116

Optical sectioning of microbial biofilms.  

UK PubMed Central (United Kingdom)

Scanning confocal laser microscopy (SCLM) was used to visualize fully hydrated microbial biofilms. The improved rejection of out-of-focus haze and the increased resolution of SCLM made it preferable...Full Text Available

1991-10-01

117

Natural Gaits of the Non-Pathological Flat Foot and High-Arched Foot  

UK PubMed Central (United Kingdom)

There has been a controversy as to whether or not the non-pathological flat foot and high-arched foot have an effect on human walking activities. The 3D foot scanning system was employed to obtain static...Full Text Available

118

Morphology and Ultrastructure of Maternal Seed Tissues of Soybean in Relation to the Import of Photosynthate  

UK PubMed Central (United Kingdom)

Cytological observations were made on developing seeds of soybean (Glycine max (L.) Merr. “Amsoy 71”) using scanning and transmission electron microscopy and light microscopy....Full Text Available

1981-05-01

119

Magnetic resonance imaging findings in 46 elbows with a radial head fracture  

UK PubMed Central (United Kingdom)

Background and purposeRadial head fractures are common, and may be associated with other injuries of clinical importance. We present the results of a standard additional MRI scan...Full Text Available

2010-06-01

120

Limitations of Tc99m-MIBI-SPECT Imaging Scans in Persistent Primary Hyperparathyroidism  

UK PubMed Central (United Kingdom)

BackgroundIn primary hyperparathyroidism (PHPT) the predictive value of technetium 99m sestamibi single emission computed tomography (Tc99m-MIBI-SPECT) for localizing pathological...Full Text Available

2011-01-01

121

Lameness, Activity Time-Budgets, and Estrus Expression in Dairy Cattle  

UK PubMed Central (United Kingdom)

The aim of the present study was to identify specific behavioral patterns that contribute to diminished estrus expression in lame cows. Behavioral scan and focal sampling were used to examine...Full Text Available

2008-12-01

122

Kaposi's sarcoma involving the thyroid in a patient with AIDS  

International Nuclear Information System (INIS)

A 30-year-old man with acquired immune deficiency syndrome (AIDS) and Kaposi's sarcoma had a palpable thyroid mass and cervical lymphadenopathy. Nuclear medicine and ultrasound scans revealed multiple thyroid nodules. Results of biopsy showed Kaposi's sarcoma metastatic to the thyroid.

123

Is energy imparted a good measure of the radiation risk associated with CT examinations  

International Nuclear Information System (INIS)

The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any measured value of energy imparted in a radiological examination since published values of the ...

124

Genome-wide linkage scan for contraction velocity characteristics of knee musculature in the Leuven Genes for Muscular Strength Study  

UK PubMed Central (United Kingdom)

The torque-velocity relationship is known to be affected by ageing, decreasing its protective role in the prevention of falls. Interindividual variability in this torque-velocity relationship is partly...Full Text Available

2008-09-01

125

Gamuts in nuclear medicine  

Energy Technology Data Exchange (ETDEWEB)

This book provides differential diagnostic possibilities of specific scan abnormalities in one volume for easy reference. This book is organized by organ systems and covers the central nervous system, the endocrine, skeletal, pulmonary, gastrointestinal, genitourinary, and cardiovascular systems. The gamuts are designed to teach differential diagnosis and to assist in the actual interpretation of patient slides.

1983-01-01

126

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2006-07-01

127

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2005-11-20

128

Facial osteomyelitis as complication of chronic sinusitis in hemophiliac-AIDS patients - scintigraphic evaluation with technetium-99m-MDP and Gallium-67; Osteomielitis da face como complicacao de sinusite cronica em hemofilicos aideticos - avaliacao cintilografica com {sup 99m} Tc-MDP e {sup 67} Ga  

Energy Technology Data Exchange (ETDEWEB)

In the paper six cases of facial osteomyelitis as a complication of chronic sinusitis in hemophiliac-AIDS patients are reported. Osteomyelitis was suggested by an increasing of erythrocyte sedimentation rate. The diagnosis was confirmed by a positive {sup 99m} Tc MDP scintigraphy. The patients were submitted to clinical treatment. The erythrocyte sedimentation rate and 67-gallium citrate scans were used in the follow-up of the therapy. Three patients had negative gallium after three weeks of organism-specific antibiotic therapy; in two patients the gallium scintigraphy remained positive. One patient did not undergo the radionuclide scan for this clinical conditions. These results suggest that MDP scans showed higher sensitivity and specificity in detection of bone disease in chronic sinusitis. Gallium scans appeared to be valuable tool in the follow-up of the infection. There are no reports in the ...

1997-01-01

129

Experimental Electron Heat Diffusion in TJ-II ECRH Plasmas  

Energy Technology Data Exchange (ETDEWEB)

Interpretative transport has been used to revisit the global scalings of TJ-II ECRH plasmas from a local perspective. Density, rotational transform and ERCH power scans were analysed based upon Thomson Scattering data (electron density and temperature) in steady state discharges. A simple formula to obtain the thermal conductivity, assuming pure diffusion and negligible convective heat fluxes was used in a set of 161 discharges. All the analysis was performed with the ASTRA transport shell. The density scan indicates that inside n=0,4 there is no significant change of e with density in the range studied (0.4 <ne>(1019m-3) 1.0), while in 0,5 <0,8 approximately, e decreases with density. In the rotational transform scan it is found that the values of e when a low order rational of the rotational transform is present locally seem to be smaller for the corresponding range, although it is apparent a general ...

2006-07-01

130

Electronic and Interfacial Properties of Pd/6H-SiC Schottky Diode ...  

Science.gov (United States)

and palladium silicides (Pd,Si) with a total. AES intensity ratio of Pd to Si of 35/65. Scanning Electron Microscopy. (SEM') of the Pd region shows that ...

131

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

132

Determination of Thermal Properties and Morphology of Eucalyptus Wood Residue Filled High Density Polyethylene Composites  

UK PubMed Central (United Kingdom)

Thermal behaviors of eucalyptus wood residue (EWR) filled recycled high density polyethylene (HDPE) composites have been measured applying the thermogravimetric analysis (TGA) and differential scanning...Full Text Available

133

Cobalt-57-bleomycin scanning of hila and mediastinum in patients with bronchial carcinoma: a prospective study.  

UK PubMed Central (United Kingdom)

Because the results with cobalt-57-bleomycin (57Co-bleo) as a tumour-seeking agent in patients with pulmonary tumours were promising, a prospective study was carried out to test the sensitivity and...Full Text Available

1976-12-01

134

Catheter Ablation for Paroxysmal Atrial Fibrillation  

Medline Plus

... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...

135

Calorimetric studies of the kinetic unfreezing of molecular motions in hydrated lysozyme, hemoglobin, and myoglobin.  

UK PubMed Central (United Kingdom)

Differential scanning calorimetric (DSC) studies of the glassy states of as-received and hydrated lysozyme, hemoglobin, and myoglobin powders, with water contents of < or = 0.25, < or...Full Text Available

1994-01-01

136

Calorimetric and spectroscopic studies of the polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines.  

UK PubMed Central (United Kingdom)

The polymorphic phase behavior of a homologous series of n-saturated 1,2-diacyl phosphatidylethanolamines was investigated by differential scanning calorimetry, 31P-nuclear magnetic resonance, and Fourier...Full Text Available

1993-04-01

137

CLINICAL VALUE, NORMATIVE RETINAL SENSITIVITY VALUES, AND INTRASESSION REPEATABILITY USING A COMBINED SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY/SCANNING LASER OPHTHALMOSCOPE MICROPERIMETER  

UK PubMed Central (United Kingdom)

PurposeTo establish normative values for macular light sensitivity and to determine the intrasession fluctuation of perimetric responses using the OPKO/OTI microperimeter.Full Text Available

2011-02-01

138

Atelectasis on pediatric chest CT: comparison of sedation techniques  

International Nuclear Information System (INIS)

Background. A change in practice at our institution resulted in increased use of anesthesia for CT scan of the chest in children who required sedation. Objective. To determine whether there is a difference in the frequency or severity of pulmonary atelectasis on CT scan in children sedated by anesthesiologists compared with children sedated by radiologists using intravenous pentobarbital. Materials and methods. Retrospective blinded review of 60 CT scans of the chest performed in 41 children. Forty-one studies in children sedated by radiologists (median age 29 months) were compared with 19 studies in children sedated by anesthesiologists (median age 25 months). Results. Atelectasis sufficient to obscure pulmonary metastases was shown in 5 of 41 (12 %) radiology sedations and 13 of 19 (68 %) anesthesiology sedations (P < 0.01). Higher grades of atelectasis were recorded in children under anesthesia (P < 0.01). ...

1999-07-01

139

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system  

International Nuclear Information System (INIS)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB)

2001-09-01

140

An unusual presentation of metastatic adenocarcinoma of lung: a case report  

UK PubMed Central (United Kingdom)

We report an unusual patient with primary adenocarcinoma of lung causing malignant pleural and pericardial effusions. The diagnosis was made only at autopsy as his staging computed tomography scan of...Full Text Available

141

Amorphous to crystalline phase transformation in Metglas reg-sign studied by Moessbauer spectroscopy  

International Nuclear Information System (INIS)

The authors present differential scanning calorimetry (DSC) and in situ Moessbauer spectroscopy results for Metglas ribbons, to which different heat treatments were made. The Curie temperature of the amorphous phase is determined and the evolution of the magnetic field of this phase is studied as a function of temperature

1997-12-01

142

A morphological and morphometric study of the prosimian lung: the lesser bushbaby Galago senegalensis.  

UK PubMed Central (United Kingdom)

The lung of the lesser bushbaby (Galago senegalensis) has been investigated morphologically and morphometrically using the transmission and scanning electron microscopes. Grossly and microscopically,...Full Text Available

1990-10-01

143

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

144

Scintigraphic detection of a radiologically equivocal fracture  

Energy Technology Data Exchange (ETDEWEB)

This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period.

1988-04-01

145

Scintigraphic detection of a radiologically equivocal fracture  

International Nuclear Information System (INIS)

This case report makes evident that in a 75 years old patient with a (cured) femoral neck fracture 15 years ago a refracture at the same site following a new trauma could not be detected by conventional X-ray. The follow-up of a radionuclide bone study, however, enabled the dignosis of a refracture. From these findings, it is further evident that the decreased bone metabolism in older patients has to be considered. Thus, although the initial bone scan following the trauma is negative, a follow-up scan should be performed within a 4 day-period. (orig.).

146

Role of Surgery After Chemotherapy in B-Cell Lymphoma of Thymus Causing Airway Compression and Right Ventricle Outflow Tract Obstruction  

British Library Electronic Table of Contents (United Kingdom)

Primary B-cell lymphoma of thymus is uncommon. We describe the case of a 23-year-old woman with a history of shortness of breath and distended neck veins of 1-month duration. A chest roentgenogram and computed tomographic chest scan of the showed a large anterior mediastinal mass. Tru-cut biopsy revealed primary B-cell lymphoma of thymus. She underwent chemotherapy with no symptomatic improvement. Post-chemotherapy computed tomographic scan of the chest showed no appreciable reduction in tumor size. Surgical excision was carried out with excellent results.

2011-01-01

147

Prospects for lithium imaging using annular bright field scanning transmission electron microscopy: A theoretical study  

British Library Electronic Table of Contents (United Kingdom)

There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.

2011-01-01

148

Local secondary-electron emission spectra of graphite and gold surfaces obtained using the Scanning Probe Energy Loss Spectrometer (SPELS)  

International Nuclear Information System (INIS)

Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.

2009-11-25

149

Beam position monitor readout and control in the SLC linac  

Energy Technology Data Exchange (ETDEWEB)

A beam position monitoring system has been implemented in the first third of the SLC linac which provides a complete scan of the trajectory on a single beam pulse. The data is collected from the local micro-computers and viewed with an updating display at a console or passed on to application programs. The system must operate with interlaced beams so the scans are also interlaced, providing each user with the ability to select the beam, the update rate, and the attenuation level in the digitizing hardware. In addition each user calibrates the hardware for his beam. A description of the system architecture will be presented. 6 refs., 4 figs.

1985-04-01

150

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The ...

2007-07-01

151

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only ...

1991-01-01

152

A Simulation Study on a Radioactive Nuclide's Distribution within a Fuel rod by a Tomographic Gamma Scanning  

Energy Technology Data Exchange (ETDEWEB)

Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and it has an accurate precision for the characterization of several ...

2006-07-01

153

A Clinical Study on the Value of a Scoring System of the Scanning Images in Liver Cirrhosis  

International Nuclear Information System (INIS)

Although the radioisotope liver scan has primarily been of use in the detection of the intra-hepatic space occupying lesions, there has been an increasing awareness of its use in evaluation of liver function. In this study, the degree of hepatomegaly, changes in shape and mottling radiodensity on each lobe and splenic visualization in the liver scans done with colloidal radiogold were numerically expressed as scores under the arbitrary standard in 210 patients with liver cirrhosis. The clinical value of this scoring system was studied with special regards to the correlation between the radiogold hepatic uptake half time and conventional liver function tests. Following were the results; 1) The normal scan appeared in 6.7% of 210 patients with liver cirrhosis. 2) The colloidal radiogold hepatic uptake half time was abnormally and progressively prolonged in parallel to severity of hepatocellular dysfunction. The mean hepatic ...

1970-09-01

154

ZZ MCB-JEF2.2, MCB Continuous-Energy Neutron Cross Section Libraries for Temperatures from 300 to 1800 K  

International Nuclear Information System (INIS)

1 - Description of program or function: MCB-JEF2.2 is a continuous-energy cross section libraries in ACE Format suitable for the MCB-1C and MCNP codes. Libraries for various materials were generated at six different Temperatures, and cover the energy range up to 20 MeV. Format: ACE. Number of groups: Continuous energy. Nuclides: H-1, H-2, H-3, He-3, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat., N-14, N-15, O-16, O-17, Na-23, F-19, Mg-nat., Al-27, Si-nat., P-31, S-32, S-33, S-34, S-36, Cl-nat, K-nat, Ca-nat., Ti-nat, V-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-59, Ni-60, Ni-61, Ni-62, Ni-64, Cu-nat, Ga-nat, Ge-72, Ge-73, Ge-74, Ge-76, As-75, Se-74, Se-76, Se-77, Se-78, Se-80, Se-82, Br-79, Br-81, Kr-78, Kr-80, Kr-82, Kr-83, Kr-84, Kr-85, Kr-86, Rb-85, Rb-86, Rb-87, Sr-84, Sr-86, Sr-87, Sr-88, Sr-89, Sr-90, Y-89, Y-90, Y-91, Zr-nat, Zr-90, Zr-91, Zr-92, Zr-93, Zr-94, Zr-95, Zr-96, Nb-93, Nb-94, Nb-95, Mo-nat, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, ...

155

Special phased array applications for pipeline girth weld inspections  

Energy Technology Data Exchange (ETDEWEB)

Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for ...

2004-07-01

156

Prospective evaluation of femoral head viability following femoral neck fracture  

International Nuclear Information System (INIS)

The bone scans of 33 patients (pts) with recent subcapital fractures (fx) of the femur were evaluated prospectively to determine their value in predicting femoral head visability. Each of the 33 pts (ll men, 22 women, age range 30-92) had a pre-operative bone scan within 72 hrs of the fx (23 pts within 24 hrs). Anterior and posterior planar views of both hips and pinhole views (50% of pts) were obtained 2 hrs after administration of Tc-99m HDP. The femoral head was classified as perfused if it showed the same activity as the opposite normal side or if it showed only slightly decreased activity. Femoral heads showing absent activity were classified as nonperfused. Overall, 20 of the 33 pts showed a photopenic femoral head on the side of the fx. Only 2 pts showed increased activity at hte site of the fx. Internal fixation of the fx was performed in 23 pts, 12 of whom had one or more follow-up scans. Five of these 12 pts ...

1984-06-05

157

Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the treatment position with 1 cm slice intervals, covering lung apex ...

1990-01-01

158

CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice  

Energy Technology Data Exchange (ETDEWEB)

Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: ...

1992-07-15

159

CT characterization of bile duct dilatation: Differential diagnosis of obstructive jaundice  

International Nuclear Information System (INIS)

Each disease affecting the bile ducts tends to produce characteristic pattern of biliary dilatation: recurrent pyogenic cholangitis causes dilatation and straightening of the larger (central) intrahepatic ducts: clonorchiasis causes dilatation of the smaller (peripheral) intrahepatic ducts; and carcinoma along the extrahepatic ducts causes (proportional) dilatation and tortuosity of both larger and smaller intrahepatic ducts. To evaluate the specificity of the pattern and morphology of the dilated biliary tree on CT scans (CT characterization) three independent radiologists who were unifamiliar with the cases were asked to classify 62 CT scans in patients with obstructive jaundice. The case population consisted of 14 cases with recurrent pyogenic cholangitis, 18 cases with clonorchiasis and 30 cases with carcinoma along the extrahepatic ducts, which were intermixed randomly. Classification was made only on the basis of CT characterization: ...

1992-07-01

160

Time-domain dynamic opto-rheology study of polymer films using step-scan FTIR time-resolved spectroscopy (S{sup 2}FTIR TRS)  

Energy Technology Data Exchange (ETDEWEB)

Step-scan Fourier transform infrared spectroscopy in conjunction with impulse stress on polymer films has been used to monitor dynamic rheological responses in real time. A novel piezo-electrically-driven polymer microrheometer was employed to apply repetitive impulses to the polymer sample while time-domain spectra were recorded. Recent results include the study of both semi-crystalline polymers such as isotactic polypropylene (iPP) and elastomers such as Estane polyester/polyurethane copolymer and Kraton tri-block copolymer. The spectral changes of iPP are consistent with frequency-domain results. For iPP at room temperature, large differences in the response times of different absorption bands are not seen. However, the orientation response of the CH{sub 3} rocking mode is slightly slower than the responses of the backbone modes. To the authors` knowledge, this is the first reported successful step-scan FTIR time-domain dynamic polymer ...

1998-07-01

161

The uterine blush. A potential false-positive in Meckel's scan interpretation  

Energy Technology Data Exchange (ETDEWEB)

To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative phase of their cycle. ...

1982-10-01

162

The measurement of the fission product ratios, {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuel by gamma scanning method  

Energy Technology Data Exchange (ETDEWEB)

We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.

1997-10-01

163

The measurement of the fission product ratios, "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuel by gamma scanning method  

International Nuclear Information System (INIS)

We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.

1988-09-18

164

Position of nuclear-medical techniques for evaluation of loosened total hip endroprostheses  

Energy Technology Data Exchange (ETDEWEB)

For diagnosis of loosening or infection after implantation of a single-side or double-side total hip endoprosthesis 59 patients being in pain were investigated by a combination of bone scan (Technetium-99m DPD) and leucocyte scan (Indium-111 labelled leucocytes). The correlation between clinical results and scintigraphic findings revealed: bone scintigraphy detects loosening of prostheses with 95% sensitivity (45/47); bone scintigraphy excludes an instable prosthesis with 89% specificity (3/27). 45% of the loosened prostheses revealed an infection (21/47): leucocyte scintigraphy could detect 17 correct positive. Three leucocyte scans of 53 prostheses without clinical signs of infection were false positive. Therefore, leucocyte scintigraphy had a sensitivity of 91% and a specificity of 94% for detecting infection. Bone scintigraphy can detect loosening of prostheses with 93% accuracy, Indium-111 labelled leucocyte ...

1985-10-01

165

Lipiodol-CT findings of hepatocellular carcinoma: Correlation with lipiodol accumulation pattern and serum AFP  

Energy Technology Data Exchange (ETDEWEB)

Early diagnosis of hepatocellular carcinoma (hepatoma) along with surgical resection is the most appropriate therapeutic modality. For this purpose, there have been many reports concerning the diagnostic value of Lipiodol-CT scan. The authors selected 45 patients with hepatoma during the period of Feb.1986 to Jan. 1988 who received a conventional CT scan, hepatic angiography and a Lipiodol-CT scan. The results were as follows: 1. There was no statistical significant between serum AFP level and mass size, morphology and amount of necrosis. 2. Tumor necrosis was observed in a single massive and multinodular type when the tumor size exceeded 5 cm. 3. Pattern II on Lipiodol-CT, homogenous accumulation of Lipiodol except for the area of inner necrosis, was most frequently demonstrated, which means that a tumor mass with hypervascularity and increased blood flow will attract Lipiodol better. 4. Lipiodol-CT was superior to ...

1989-12-15

166

Imaging of dialysis-related amyloid (AB-amyloid) deposits with sup 131 I-beta 2-microglobulin  

Energy Technology Data Exchange (ETDEWEB)

The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled ...

1990-12-01

167

High Throughput Screening for the Discovery of More Efficient Catalysts for Emissions Control  

Energy Technology Data Exchange (ETDEWEB)

High-throughput synthesis and screening methods have been developed for the discovery of highly active catalysts for the control of emissions from stationary and mobile sources. Low temperature CO oxidation, CO methanation, NOx abatement and the destruction of Volatile Organic Compounds (VOCs) will be discussed. The discovery libraries for primary screening consisted of both 11x11 and 16x16 catalyst arrays on 3 inch and 4 inch quartz wafers, respectively. Catalysts were prepared by robotic liquid dispensing techniques and screened for catalytic activity in Symyx's Scanning Mass Spectrometer. The screening protocols encompassed mixed metal oxides, perovskites and supported base and noble metals. Active hits were further optimized in focus libraries using shallower compositional gradients. The ScanMS is a fast serial screening tool that uses flat wafer catalyst surfaces, local laser heating, a scanning/sniffing ...

2004-03-31

168

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...

2000-05-01

169

Dimensionless energy confinement scaling in W7-AS  

International Nuclear Information System (INIS)

Energy confinement in W7-AS has been analyzed in terms of dimensionally exact form free functions employing Bayesian probability theory. The confinement function was set up as a linear combination of dimensionally exact power law terms as already proposed very early by Connor and Taylor. Generation of this expansion basis is dictated by the basic plasma model which one assumes. Based upon data accumulated in W7-AS, which contains the energy content for a wide variety of variable settings, predictions for single variable scans are made. The scaling functions for density and power scans, respectively, are in quantitative agreement with data collected in W7-AS. The result of a single variable scan is therefore already hidden in the data obtained for arbitrary variable choices and can be extracted from the latter by a proper data analysis. Furthermore, the optimal model for the description of the global transport in W7-AS is ...

1999-12-01

170

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...

1981-01-01

171

Computed Tomography in pulmonary cystic fibrosis  

International Nuclear Information System (INIS)

This study was aimed at evaluating CT sensitivity in identifying the signs of pulmonary cystic fibrosis (CF). The chests of 39 patients (16 males and 23 females, mean age 19.1 years) were examined by CT: all patients had been given a clinical score according to Schwachman and Kulckzycki criteria. Thickened bronchial walls were observed in all cases, which are typical of peribronchitis. Bronchiectases were present in 87% of cases; their extent, pattern and localization were exactly shown on CT scans. Bronchoceles were seen on CT scans in 64% of patients; less frequent was the finding of atelectases and subpleural bullous emphysema. In a great number of patients (64% and 82%, respectively) pleural thickening and hilar adenopathy were demonstrated on CT scans. In conclusion, our results confirm CT as a more sensitive method than conventional radiography to identify and locate the signs of pulmonary CF. The early identification ...

1991-01-01

172

Circulation, bone scans, and tetracycline labeling in microvascularized and vascular bundle implanted rib grafts  

Energy Technology Data Exchange (ETDEWEB)

The circulation in microvascularized rib grafts has been compared with that in conventional rib grafts and in those augmented by a direct vascular bundle implantation into the bone grafts. A new experimental model has been designed to correlate vascular perfusion, bone scan patterns, tetracycline labeling, and histological findings in these bone grafts. Posterior microvascularized rib grafts were found to have a circulatory pattern identical to that of the normal rib. Failed microvascularized rib grafts were revascularized more slowly than conventional rib grafts. Vascular bundles implanted into rib grafts remained patent and increased the rate of revascularization. The stripping or preservation of periosteum had no observable effects on the rate or pattern of conventional rib graft revascularization. The circulation in rib grafts was accurately reflected in technetium 99 bone scans, as was the patency of the anastomoses of microvascularized ...

1984-11-01

173

3-dimensional observations of atmospheric variables during the field campaign COPS  

Energy Technology Data Exchange (ETDEWEB)

The Convective and Orographically-induced Precipitation Study (COPS) has the aim to advance the quality of forecasts of orographically-induced precipitation in complex terrain. COPS is a Research and Development Project of the World Weather Research Program and considered to be one of the largest field campaigns on quantitative precipitation forecasting that has been performed so far. A network of state-of-the-art active and passive remote sensing systems was combined with in total 10 airborne platforms, Meteosat rapid scans and dense networks of standard meteorological instruments during the three months long field phase (June-August, 2007) in south-western Germany/eastern France to observe atmospheric variables in the three spatial dimensions and in time. By the University of Hohenheim, two novel ground-based mobile scanning lidar systems were deployed: a scanning rotational Raman lidar which provides combined ...

2008-05-01

174

[75Se]Selenomethionine scanning for parathyroid localization should be abandoned  

International Nuclear Information System (INIS)

Image subtraction techniques, in conjunction with [75Se]selenomethionine (75Se) scintigraphy, have recently been suggested to be a potentially valuable tool for localization of parathyroid abnormalities. With use of these techniques, we prospectively studied 15 patients scheduled for parathyroid operations. Postoperatively, all were normocalcemic. Anterior scintiscans of the neck were divided into quadrants, and regions of enhanced uptake were assigned to one or more quadrants. On this basis, by chance alone a minimum of 25% of single-gland enlargements would be assigned to the correct quadrant of the neck. We found that by use of 75Se scanning only 8 of 22 abnormal glands (36%) were assigned to the quadrant of the neck in which they were found intraoperatively. In no case was a clearly visualized focus of parathyroid activity encountered. These results do not justify the continued use of 75Se scintigraphy with or without image subtraction in the preoperative ...

175

Vessel elements present in the secondary xylem of Trochodendron and Tetracentron (Trochodendraceae)  

British Library Electronic Table of Contents (United Kingdom)

For almost 150 years, the two monotypic genera Trochodendron and Tetracentron (Trochodendraceae) have been considered to share an unusual and primitive feature in angiosperms - the lack of vessels in their wood. Therefore, they have been classified in a basal position in the angiosperms. Our observations by light microscopy, low-vacuum environmental scanning electron microscopy (ESEM) and high-vacuum scanning electron microscopy (SEM) both in fresh and FAA-fixed materials consistently showed the presence of tracheary elements differentiated into two types in both genera. In Trochodendron, the tracheary elements can be divided into perforate vessel elements and imperforate fiber-tracheids and tracheids. The vessel elements show end and lateral walls. The pits on the end walls are elongate- ...

2011-01-01

176

Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system  

Energy Technology Data Exchange (ETDEWEB)

The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.

2003-05-01

177

Towards atomic scale engineering of rare-earth-doped SiAlON ceramics through aberration-corrected scanning transmission electron microscopy  

British Library Electronic Table of Contents (United Kingdom)

Direct visualization of rare earths in @a- and @b-SiAlON unit-cells is performed through Z-contrast imaging technique in an aberration-corrected scanning transmission electron microscope. The preferential occupation of Yb and Ce atoms in different interstitial locations of @b-SiAlON lattice is demonstrated, yielding higher solubility for Yb than Ce. The triangular-like host sites in @a-SiAlON unit cell accommodate more Ce atoms than hexagonal sites in @b-SiAlON. We think that our results will be applicable as guidelines for many kinds of rare-earth-doped materials.

2011-01-01

178

Thermal and mechanical properties of poly(vinyl alcohol) plasticized with glycerol  

British Library Electronic Table of Contents (United Kingdom)

Abstract Thermomechanical behavior of membranes based on blends of poly(vinyl alcohol) (PVA) with different weight percentage (wt %) of glycerol has been studied. Solid-state PVA/Glycerol polymer membranes were prepared by a solution casting method. The films were studied for thermal characteristics by differential scanning calorimetry (DSC) and thermogravimetric analysis and for the mechanical properties including hardness and modulus by nanoindentation method. The dispersion of glycerol within the polymer matrix was examined using scanning electron microscopy. Fourier transform infrared spectroscopy was used to confirm the formation of hydrogen bonding between the plasticizer and PVA in their blends and also to provide information on compatibility and physical interactions between the gl...

2011-01-01

179

Subdural effusions in children under two years. Clinical and computer-tomographical data  

Energy Technology Data Exchange (ETDEWEB)

We investigated 161 children under 24 months of age by CT of the skull and reviewed the anamnestic and clinical history. 87 children showed subdural effusions, and 74 did not. There were 33 patients with other pathological findings in CT, and 41 had normal scans. Age and sex distribution as well as localization of the subdural effusions were consistent with the literature. The 87 children with subdural effusions represented 17% in a sample of about 5000 CT scans. CT was the most reliable method for diagnosis of subdural effusions, compared to other techniques. There was a preponderance of small subdural effusions from 1 to 7 mm thickness (51%). Other CT abnormalities accompanying subdural effusions were found. Most frequently the interhemispheric sulcus was dilated and an internal hydrocephalus was present. Also in our group there were 7 anamnestical and 6 clinical symptoms highly diagnostic of subdural effusions.

1980-05-01

180

Processing and characterization of chitosan microspheres to be used as templates for layer-by-layer assembly  

British Library Electronic Table of Contents (United Kingdom)

Chitosan (Ch) microspheres have been developed by precipitation method, cross-linked with glutaraldehyde and used as a template for layer-by-layer (LBL) deposition of two natural polyelectrolytes. Using a LBL methodology, Ch microspheres were alternately coated with hyaluronic acid (HA) and Ch under mild conditions. The roughness of the Ch-based crosslinked microspheres was characterized by atomic force microscopy (AFM). Morphological characterization was performed by environmental scanning electron microscopy (ESEM), scanning electron microscopy (SEM) and stereolight microscopy. The swelling behaviour of the microspheres demonstrated that the ones with more bilayers presented the highest water uptake and the uncoated cross-linked Ch microspheres showed the lowest uptake capability. Micros...

2010-01-01

181

Precise measurement of a focused ion beam profile  

Energy Technology Data Exchange (ETDEWEB)

The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.

1987-06-01

182

Polarised neutron reflectometry study of Co/CoO exchange-biased multilayers  

Energy Technology Data Exchange (ETDEWEB)

We have investigated via SQUID magnetometry and polarised neutron reflectivity the exchange-bias effect in CoO/Co sputtered multilayers. In particular, we studied the magnetisation reversal and the time relaxation of the exchange-bias field close to the coercive field H{sub c1}. Neutron intensities of all four cross sections (I++, I+-, I-+, I-) were recorded at the position of the first multilayer Bragg peak while scanning the magnetic field. From such scans we infer that the magnetisation reversal for the ascending as well as for the descending branch of the magnetic hysteresis occurs not by in-plane rotation but through domain-wall movements. The exchange-bias field, H{sub EB}, is strongly affected by thermal fluctuations. H{sub EB} decreases, following an exponential decay function with a half-life time of about 580 s at T=240 K. (orig.)

2002-07-01

183

PROBING NEAR-SURFACE ATMOSPHERIC TURBULENCE WITH LIDAR MEASUREMENTS AND HIGH-RESOLUTION HYDRODYNAMIC MODELS  

Energy Technology Data Exchange (ETDEWEB)

As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between spatial-temporal resolution and coverage of the ...

2000-11-01

184

Neutron intensity measurements of BWR spent fuels  

International Nuclear Information System (INIS)

A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)

2000-03-01

185

Miscibility enhancement of PP/PBT blends with a side-chain liquid crystalline ionomer  

British Library Electronic Table of Contents (United Kingdom)

Side-chain liquid crystalline ionomer (SLCI) containing sulfonic acid groups with a polymethylhydrosiloxane main-chain was used in the blends of polypropylene (PP) and polybutylene terephthalate (PBT) as a compatibilizer. The crystalline behavior, morphological, and mechanical properties of the blends were investigated in detail by differential scanning calorimetry (DSC), polarizing optical microscope (POM), Fourier transforms infrared spectroscopy (FTIR), and scanning electron microscopy (SEM). Revealed by the shift of Tm in DSC thermogram and the shift of the absorbed peak in FTIR spectra, specific interaction led to stronger interfacial adhesion between these phases, which resulted in much finer dispersion of the minor PBT phase in PP matrix. The SLCI containing sulfonate acid groups ac...

2009-01-01

186

Mechanism of filler action in reducing the wear of PTFE polymer by differential scanning calorimetry  

British Library Electronic Table of Contents (United Kingdom)

Two types of representative nanometer materials, i.e., fibroid nanometer attapulgite and approximate spherical ultrafine diamond, were selected as fillers of polytetrafluoroethylene (PTFE) to study the mechanism of the wear-reducing actions of the fillers in PTFE composites. The friction and wear tests were performed on a block-on-ring wear tester under dry sliding conditions. Differential scanning calorimetry (DSC) was used to investigate material microstructure and to examine modes of failure. No significant change in coefficient of friction was found, but the wear rate of PTFE composites was orders of magnitude less than that of pure PTFE. DSC analysis revealed that nanometer attapulgite and ultrafine diamond played a heterogeneous nucleation role in PTFE matrix and consequently resulte...

2007-01-01

187

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system; Interventionelle MR-Tomographie: Klinische Erfahrungen mit einem 1,5 Tesla System  

Energy Technology Data Exchange (ETDEWEB)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.) [Deutsch] Es wurde die klinische Durchfuehrbarkeit interventioneller Techniken an einem kombinierten Durchleuchtungs- und MR-Arbeitsplatz untersucht. Dieses Hybridsystem erwies sich bei einer Vielzahl interventioneller Eingriffe als vorteilhaft. Der 1,5 Tesla-Magnet ist offenen MR-Systemen hinsichtlich Bildqualitaet und Messzeit ueberlegen. (orig.)

1997-05-01

188

Impact of Cr3C2/VC addition on the dry sliding friction and wear response of WC-Co cemented carbides  

British Library Electronic Table of Contents (United Kingdom)

Two grades of WC-10wt.%Co cemented carbide with or without addition of Cr3C2/VC grain growth inhibitor during liquid phase sintering were produced with the goal to investigate their reciprocating sliding friction and wear behaviour against WC-6wt.%Co cemented carbide under unlubricated conditions. The tribological characteristics were obtained on a Plint TE77 tribometer using distinctive normal contact loads. The generated wear tracks were analyzed by scanning electron microscopy and quantified topographically using surface scanning equipment. The post-mortem obtained wear volumes were compared to the online assessed wear. Correlations between wear volume, wear rate and coefficient of friction on the one hand and sliding distance and microstructural properties on the other hand were determ...

2009-01-01

189

Fuel element powers, STVU masses, and burnups from gamma-scanning data: Preliminary analysis of irradiated ORR (Oak Ridge Research Reactor) LEU fuel elements  

Energy Technology Data Exchange (ETDEWEB)

Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.

1988-01-01

190

Focused ion beam sculpting curved shapes.  

Energy Technology Data Exchange (ETDEWEB)

A focused ion beam (FIB) is used to accurately sculpt predetermined micron-scale, curved shapes in a number of solids. Using a digitally scanned ion beam system, various features are sputtered including hemispheres and sine waves having dimensions from 1-50 {micro}m. Ion sculpting is accomplished by changing pixel dwell time within individual boustrophedonic scans. The pixel dwell times used to sculpt a given shape are determined prior to milling and account for the material-specific, angle-dependent sputter yield, Y({theta}), as well as the amount of beam overlap in adjacent pixels. A number of target materials, including C, Au and Si, are accurately sculpted using this method. For several target materials, the curved feature shape closely matches the intended shape with milled feature depths within 5% of intended values.

2005-02-01

191

Finite element analysis of a scanning x-ray microscope micropositioning stage  

Energy Technology Data Exchange (ETDEWEB)

A micropositioning stage for use with an x-ray microscope has been developed to scan samples over a 100 {mu}m{times}100-{mu}m area with a resolution of 100 A. The stage employs flexure hinges driven by piezoelectric actuators to achieve this high positioning accuracy. Due to the severe geometry of the hinges, stresses and deflections are determined (via finite element methods) to ensure a credible design. Since the stage is to be used in a stepping capacity, natural frequencies are computed to identify resonant conditions which could potentially cause excessive deflections. The finite element models show that the stage responds like a discrete lumped-mass system for the lower modes, and a continuous system with flexural characteristics for the higher modes.

1992-01-01

192

Extracellular matrix of plant callus tissue visualized by ESEM and SEM  

British Library Electronic Table of Contents (United Kingdom)

Actinidia deliciosa endosperm-derived callus culture is stable over a long period of culture. This system was used to investigate the ultrastructure of extracellular matrix occurring in morphogenic tissue. Specimens were prepared by different biological techniques (chemical fixation, liquid nitrogen fixation, glycerol substitution, critical-point drying, lyophilization) and observed by scanning electron microscopy (SEM). Fresh and wet samples were analyzed with the use of environmental scanning electron microscopy (ESEM). Extracellular matrix was observed on the surface of cell clusters as a membranous layer or reticulated network, shrunken or wrinkled, depending on the procedure. Generally, shrunken membranous layers with a globular appearance and fibrils were noted after critical-point d...

2010-01-01

193

Estimation of dry rubber content in natural rubber latex by differential scanning calorimetry  

British Library Electronic Table of Contents (United Kingdom)

Differential Scanning Calorimetry (DSC) is employed to study the changes in enthalpy of natural rubber latex samples when heated under a controlled temperature program. It is found that the mass normalized areas of the DSC curves between room temperature and 170??C for different latex samples are inversely proportional to the dry rubber content (DRC) of the samples, measured following the weighing and drying method. The changes in total enthalpy of the samples in this temperature range are interpreted as due to the variations in the quantity of water present in the samples. The measurements have been repeated by diluting selected samples with known quantities of water, and it is found that the normalized areas of the DSC curves are directly proportional to the amount of water added to the ...

2010-01-01

194

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

195

Environmental, scanning electron and optical microscope image analysis software for determining volume and occupied area of solid-state fermentation fungal cultures  

British Library Electronic Table of Contents (United Kingdom)

Abstract Here we propose a software for the estimation of the occupied area and volume of fungal cultures. This software was developed using a Matlab platform and allows analysis of high-definition images from optical, electronic or atomic force microscopes. In a first step, a single hypha grown on potato dextrose agar was monitored using optical microscopy to estimate the change in occupied area and volume. Weight measurements were carried out to compare them with the estimated volume, revealing a slight difference of less than 1.5%. Similarly, samples from two different solid-state fermentation cultures were analyzed using images from a scanning electron microscope (SEM) and an environmental SEM (ESEM). Occupied area and volume were calculated for both samples, and the results obtained w...

2011-01-01

196

Electron beam, ion beam, X-ray optical techniques for fabricating surface-acoustic-wave and thin-film optical devices  

International Nuclear Information System (INIS)

Most surface-acoustic-wave and thin-film optical devices are made by the planar fabrication process. The exposure of the pattern in the polymer film is the first and most crucial step in ensuring desired device geometry, dimensional control, and freedom from pattern distortion. The methods of exposing the polymer film include: optical projection, conventional contact printing, conformable photomask contact printing, holographic recording, scanning electron beam lithography, projection electron lithography, and x-ray lithography. In this paper scanning electron beam lithography, conformable photomask contact printing, holographic recording, and x-ray lithography are discussed. In the last section, ion beam etching of relief structures is discussed.

197

Electrical properties of focused-ion-beam boron-implanted silicon  

International Nuclear Information System (INIS)

Electrical properties of 16 keV, focused-ion-beam (FIB) (beam diameter: 1 #mu#m, current density: 50 mA/cm"2) boron-implanted silicon layers have been investigated as a function of beam scan speed and ion dose, and compared with those obtained by conventional implantation (current density: 0.4 #mu#A/cm"2). High electrical activation of the FIB implanted layers is obtained by annealing below 800"0C as a result of the increase in amorphous zones created in the implanted layers. Amorphous zone overlapping is assumed to occur at FIB implantation doses of 3 - 4 x 10"1"5 ions/cm"2 from the results of electrical activation and the carrier profile of implanted regions annealed at low temperature, if beam scan speed is lowered to about 10"-"2 cm/s. (author).

198

Effects of modification on microstructure and properties of ultrahigh carbon (1.9wt.% C) steel  

British Library Electronic Table of Contents (United Kingdom)

The effects of a modifier that contains Rare Earths (RE), low melting point alloy (Al-Bi-Sb) and Ca-Si alloy on an ultrahigh carbon steel containing 1.9wt.% C were studied. Microstructure characterization was carried out with optical microscopy (OM) and scanning electronic microscopy (SEM) combined with energy-dispersive spectrometry (EDS). Upon modification, the continuous eutectic carbide network structure was broken up and changed to a partly isolated and finer blocky structure in the as-cast alloy. Differential scanning calorimetry (DSC) revealed that the eutectoid temperature increased and the eutectic temperature decreased for the modified alloy. Modification also improved the impact toughness of the tempered steel, with a significant increase from 6.5 to 12.6Jcm^-^2, despite the har...

2011-01-01

199

Effects of carbon fiber surface treatment on the friction and wear behavior of 2D woven carbon fabric/phenolic composites  

British Library Electronic Table of Contents (United Kingdom)

To improve the friction and wear behavior of carbon fabric reinforced polymer composites (CFRP), nano-SiO2 was deposited on the fabric surface. The friction and wear behavior of the resulting composites were investigated on a model ring-on-block test rig. Experimental results revealed that fiber surface treatment contributed to largely improve the tribological properties of the CFRP composites. Scanning electron microscope (SEM) investigation showed that the worn surface of the surface modified CFRP composite was smoother under given load and sliding rate. Field emission scanning electron microscopy (FESEM), FTIR and X-ray photoelectron spectroscopy (XPS) studies of the carbon fiber surface showed that nanostructured Sio2 thin film can be obtained by SiO2 sols deposition, which improved th...

2009-01-01

200

Development and application of gamma scanning technology for on-line investigation of industrial process columns and vessels  

International Nuclear Information System (INIS)

Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (author)

1998-10-30

201

Chemical, electrical and electrochemical characterization of hybrid organic/inorganic polypyrrole/PW12O40^3^- coating deposited on polyester fabrics  

British Library Electronic Table of Contents (United Kingdom)

A study of the stability of conducting fabrics of polyester (PES) coated with polypyrrole/PW12O40^3^- (organic/inorganic hybrid material) in different pH solutions (1, 7, 13) has been done. Washing tests were also done in views of its possible application in electronic textiles such as antistatic clothing. X-ray photoelectron spectroscopy (XPS) studies have been done to quantify the amount of counter ion that remains in the polymer matrix and determine the doping ratio (N^+/N) after the different tests. Scanning electron microscopy (SEM) was also used to observe morphological differences after the different tests. Surface resistivity changes were measured by means of electrochemical impedance spectroscopy (EIS). Scanning electrochemical microscopy (SECM) was employed to measure changes in ...

2011-01-01

202

Characterisation and use of biomass fly ash in cement-based materials  

British Library Electronic Table of Contents (United Kingdom)

This paper presents results about the characterisation of the biomass fly ashes sourced from a thermal power plant and from a co-generation power plant located in Portugal, and the study of new cement formulations incorporated with the biomass fly ashes. The study includes a comparative analysis of the phase formation, setting and mechanical behaviour of the new cement-fly ash formulations based on these biomass fly ashes. Techniques such as X-ray diffraction (XRD), X-ray fluorescence spectroscopy (XRF), thermal gravimetric and differential thermal analysis (TG/DTA), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and environmental scanning electron spectroscopy (ESEM) were used to determine the structure and composition of the formulations. Fly ash F1 from the t...

2009-01-01

203

Cavity ringdown spectroscopy with a continuous-wave laser: calculation of coupling efficiency and a new spectrometer design.  

Science.gov (United States)

For the efficient operation of a cavity ringdown spectroscopy (CRDS) system utilized with a continuous-wave (cw) laser, we numerically analyze the coupling efficiency of a cw laser to a ringdown cavity in terms of changes in the scanning rate, the laser linewidth, and the mirror reflectivity. We also demonstrate a new simple design for a CRDS system that can produce a CRDS signal with only a piezoelectric transducer (PZT), without the acousto-optic modulator that is usually adopted to switch off the cw laser beam that enters the cavity. Furthermore, we investigate the feasibility of the cw CRDS technique with a fast-scanning PZT by recording a CRDS spectrum of acetylene overtones. The detection sensitivity that corresponds to the noise-equivalent absorption is found to be approximately 3 x 10(-9)/cm. PMID:18305817

1999-03-20

204

Benign lymphoepithelial lesion of the parotid gland in AIDS patients: CT characteristics  

International Nuclear Information System (INIS)

Contrast agent-enhanced CT scans in nine male patients with histologically proved benign lymphoepithelial lesions of the perotid gland were reviewed. All scans showed cystic-appearing masses with peripheral rim enhancement corresponding to the macroscopic appearance of the lesion. Five patients were seropositive for human immunodeficiency virus (HIV) infection or had infections seen in acquired immunodeficiency syndrome. Three patients were members of high-risk groups. Only one patient had symptoms of the SICCA syndrome. Once a rare cause of parotid gland enlargement, benign lymphoepithelial lesions have recently been seen with increasing frequency in patients with HIV infection. Although the CT appearance is not pathognomic, correlation results of aspiration cytology and with clinical history can lead to a preoperative diagnosis of a benign lymphoepithelial lesion.

205

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

206

Applications of environmental scanning electron microscopy (ESEM) in the study of novel drying latex films  

Energy Technology Data Exchange (ETDEWEB)

We have employed Environmental Scanning Electron Microscopy (ESEM) and Energy Dispersive X-ray (EDX) analysis to study the microstructural evolution of acrylic latex stabilised with a novel polysaccharide derived from agricultural waste. The analysis revealed that the micro structure of the latex in the 'wet' state consists of individual particles and clusters. Upon evaporation a discontinuous film is formed, with voids present within its structure, which is inconsistent with the conventional descriptions of film formation. Further ESEM examination of 'dry' specimens revealed that aging resulted in the formation of dendritic structures on the surfaces of the latex films, which EDX analysis confirmed to have been formed via crystallisation of salt. The experimental evidence suggests that the clusters, which are part of the structure of the latex, may act as nucleation centres that would allow the dendrites to form.

2008-08-15

207

A novel gamma scanning system for on-line diagnostic inspection of industrial process columns  

International Nuclear Information System (INIS)

A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)

208

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

209

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

210

A digitization and multimedia project at Quinnipiac University, Hamden, Connecticut, USA  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The purpose of this paper is to encourage other libraries to provide access to their own original content via the web. By way of case study, the process of identifying materials, scanning them and creating web access to original content will be explored. Design/methodology/approach - To implement a book digitization project, three major things need to be present. The library must own material that was published prior to 1923, making them safely out of copyright in the USA; the library needs access to server space on the web and the library needs to own scanning equipment. Findings - This project demonstrated that a library does not necessarily need to obtain grant funding to begin an effective and successful digitization program. It also revealed a few things that would improve t...

2007-01-01

211

ZZ DECAYREM/C, Decay Spectra Library for EXREM Calculation  

International Nuclear Information System (INIS)

Description of problem or function: Format: EXREM III; Nuclides: radioactive decay data on 252 Nuclides: 1H-3, 4Be-7, 6C-11, 6C-14, 7N-13, 8O-15, 9F-18, 11Na-22, 11Na-24, 12Mg-28, 13Al-28, 15P-32, 15P-33, 16S-35, 17Cl-36, 17Cl-38, 18A-37, 18A-39, 19K-40, 19K-42, 19K-43, 20Ca-45, 20Ca-47, 20Ca-49, 21Sc-46, 21Sc-47, 21Sc-49, 24Cr-51, 25Mn-52M, 25Mn-52, 25Mn-54, 26Fe-52, 26Fe-55, 26Fe-59, 27Co-56, 27Co-57, 27Co-58, 27Co-60, 28Ni-56, 28Ni-63, 29Cu-64, 30Zn-65, 30Zn-69M, 30Zn-69, 31Ga-67, 31Ga-68, 32Ge-77, 33As-76, 33As-77, 34Se-75, 35Br-80M, 35Br-80, 35Br-82, 35Br-83, 35Br-84, 36Kr-79, 36Kr-83M, 36Kr-85M, 36Kr-85, 36Kr-87, 36Kr-88, 37Rb-84, 37Rb-86, 37Rb-87, 37Rb-88, 37Rb-89, 37Rb-90M, 37Rb-90, 38Sr-85, 38Sr-87M, 38Sr-89, 38Sr-90, 38Sr-91, 38Sr-92, 38Sr-93, 39Y-87, 39Y-88, 39Y-90, 39Y-91M, 39Y-91, 39Y-92, 39Y-93, 40Zr-93, 41Nb-93M, 40Zr-95, 40Zr-97, 41Nb-95M, 41Nb-95, 41Nb-97M, 41Nb-97, 42Mo-99, 43Tc-99M, 43Tc-99, 44Ru-103, 44Ru-105, 44Ru-106, 45Rh-103M, 45Rh-105M, 45Rh-105, 45Rh-106, ...

212

VIIRS F1 Pre-Launch Calibration d Ch i i and Characterization:  

Science.gov (United States)

0.5% (one sigma) for scan angles less than 55.84 degrees off nadir ... Two polarization sheets and one blocking filter were used .... Polarization factors of different detectors in a given band cross and the cross point ...

213

Thermal NDE method for thermal spray coatings  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a feasibility demonstration of a thermal scanning NDE system for thermal spray coatings. Non-bonds were detected between several types of coatings and their substrates. Aluminum anti-skid coatings having very rough surfaces were included. A technique for producing known non-bond areas for calibrating and demonstrating NDE methods was developed.

1982-01-01

214

The implementation of SOMO (SOlution MOdeller) in the UltraScan analytical ultracentrifugation data analysis suite: enhanced capabilities allow the reliable hydrodynamic modeling of virtually any kind of biomacromolecule  

UK PubMed Central (United Kingdom)

The interpretation of solution hydrodynamic data in terms of macromolecular structural parameters is not a straightforward task. Over the years, several approaches have been developed to cope...Full Text Available

2010-02-01

215

Technetium-99m DISIDA hepatobiliary agent in diagnosis of hepatocellular carcinoma: relationship between detectability and tumor differentiation  

Energy Technology Data Exchange (ETDEWEB)

The present investigation was aimed to assess the usefulness of biliary agents scintigraphy in the diagnosis of hepatocellular carcinoma (HCC) and to ascertain the relationship between the uptake of these agents and the degree of HCC differentiation. Forty-four patients with this hepatic cancer were included in the study. Liver scans were performed 20 min and 3 hr after the administration of 99mTc diisopropyliminodiacetic acid (DISIDA). DISIDA scintigraphy could not be assessed in six cases. In 16 (42%) out of the remaining 38 patients, the tumor exhibited equal or greater radioactivity uptake than the surrounding liver. In six out of these 16 patients, tumor uptake was apparent in the early and delayed hepatic scans, while in the other ten subjects radioactivity uptake by the HCC could only be detected in the 3-hr delayed scans. In the remaining 22 patients, HCC appeared as a cold area. Tumor location by this technique did ...

1988-12-01

216

Regulatory T cells inhibit stable contacts between CD4+ T cells and dendritic cells in vivo  

UK PubMed Central (United Kingdom)

Regulatory T (T reg) cells exert powerful down-modulatory effects on immune responses, but it is not known how they act in vivo. Using intravital two-photon laser scanning microscopy we determined that,...Full Text Available

2006-03-20

217

Radioisotope imaging of brain tumors in two rhesus monkeys. Final report  

Energy Technology Data Exchange (ETDEWEB)

Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.

1988-04-01

218

Power density distribution by gamma scanning of fuel rods measurement technique in RA-8 critical facility  

International Nuclear Information System (INIS)

Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)

1999-10-26

219

Personal computers restructuring tomorrow's nets  

Energy Technology Data Exchange (ETDEWEB)

Discusses alternative futures for distributing future personal computers, via data communications networks. The author scans and extrapolates some of the advances for impacting the emerging future of information utilities now sprouting up thoroughout the world. In particular he looks at the future of personal computers in the field of artificial intelligence,, for expert knowledge-based systems.

1982-01-01

220

Molecules with polymerizable ligands as precursors to porous doped materials  

Energy Technology Data Exchange (ETDEWEB)

Titanium and aluminum alkoxide derivatives with polymerizable ligands such as 2-(methacryloyloxy)ethylacetoacetate (HAAEMA), oleic acid and geraniol (HOGE) have been obtained. The various compounds have been characterized by FT-IR and NMR {sup 1}H. Copolymerization with styrene and divinylbenzene affords porous doped organic materials which have been characterized by scanning electron microscopy (SEM), elemental analysis, density measurements.

1996-12-31

221

Micromachining using focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)

1994-11-16

222

Implant detectibility of intervertebral disc spacers in post fusion MRI: evaluation of the MRI scan quality by using a scoring system - an in vitro study  

International Nuclear Information System (INIS)

Intervertebral spacers for anterior spine fusion are made of different materials, such as titanium and cobalt chromium alloys and carbon fiber-reinforced polymers. Implant-related susceptibility artifacts can decrease the quality of MRI scans. The aim of this cadaveric study was to demonstrate the extent that implant-related MRI artifacting affects the postfusion differentiation of determined regions of interest (ROIs). In six cadaveric porcine spines, we evaluated the postimplantation MRI scans of a titanium, cobalt-chromium and carbon spacer that differed in shape and surface qualities. A spacer made of human cortical bone was used as a control. A defined evaluation unit was divided into ROIs to characterize the spinal canal as well as the intervertebral disc space. Considering 15 different MRI sequences read independently by an interobserver-validated team of specialists the artifact-affected image quality of the median MRI slice was rated ...

2007-02-01

223

Fouling Study of Silicon Oxide Pores Exposed to Tap Water  

Energy Technology Data Exchange (ETDEWEB)

We report on the fouling of Focused Ion Beam (FIB)-fabricated silicon oxide nanopores after exposure to tap water for two weeks. Pore clogging was monitored by Scanning Electron Microscopy (SEM) on both bare silicon oxide and chemically functionalized nanopores. While fouling occurred on hydrophilic silicon oxide pore walls, the hydrophobic nature of alkane chains prevented clogging on the chemically functionalized pore walls. These results have implications for nanopore sensing platform design.

2007-07-12

224

Fault diagnosis of rolling bearing based on cyclic spectrum density  

International Nuclear Information System (INIS)

The paper considered the vibration signals of rotating equipment as cyclo stationary signals through analyzing the features of this kind of signals. Based on the analytic method of cyclic spectrum density, the paper pointed out that the impact frequency could be extracted effectively with the help of scanning cyclic frequency domain. The validity of the method of cyclic spectrum density is proved by simulating signals and the method is applied to the diagnosis of rolling bearings. (authors)

2009-09-01

225

Electrochemical stability of silicon/carbon composite anode for lithium ion batteries  

International Nuclear Information System (INIS)

Silicon/carbon composite anode materials were prepared by pyrolyzing the phenol-formaldehyde resin (PFR) mixed with silicon and graphite powders. Scanning electron microscopic (SEM) observation showed that the morphology stability of the composite electrodes can be retained during cycling. A structure evolution mechanism is proposed to illuminate the enhancement of cycleability of the composite electrode. The composite used as anode material for lithium ion batteries possesses a reversible capacity of over 700 mAh/g.

2007-04-20

226

Effect of environmental variables on localized corrosion of high-performance container materials  

Energy Technology Data Exchange (ETDEWEB)

Electrochemical cyclic potentiodynamic polarization (CPP) experiments were performed on several candidate high-performance waste package container materials to evaluate their susceptibility to localized corrosion in aqueous environments relevant to the potential underground high-level nuclear waste repository. This paper presents the results of this study showing the effects of chloride ion (Cl) concentrations, pH, temperature, and electrochemical potential scan rate on the pitting corrosion behavior of these materials.

1997-01-01

227

Differential diagnosis of tumorous lesions in the iliac bone in children  

Energy Technology Data Exchange (ETDEWEB)

The radiologic appearance of inflammatory and tumorous lesions in the iliac bone is characterized by destructive alterations and consolidations simultaneously. This pattern is nonspecific. The value of plain films of this area is compromised by the anatomy of the iliac bone and by overlying structures. Therefore tomography, computer tomography and bone scans are necessary. Difficulties in differentiation between benign and malignant lesions are discussed and case reports are given. The importance of histologic examination is stressed.

1984-02-01

228

Dielectric barrier discharge using corona-modified silicone rubber  

Science.gov (United States)

Results from scanning electron microscopy, Fourier transform infrared spectroscopy and the measurement of thermally stimulated current show that a high density of the physical defects and the chemical defects are introduced into the surface of the silicone rubber plates after they are treated by corona discharge plasma. These defects behave electrically as shallow electron traps, leading to the formation of a uniform discharge in air at higher pressure when the corona-modified silicone rubber is used in dielectric barrier discharge.

2008-10-01

229

Development and application of a gamma scanning system for LLW and MLW packages  

International Nuclear Information System (INIS)

The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.

1993-09-05

230

Detection of CTX-M-Type Extended-Spectrum Beta-Lactamase (ESBLs) by Testing with MicroScan Overnight and ESBL Confirmation Panels?  

UK PubMed Central (United Kingdom)

CTX-M extended-spectrum beta-lactamases (ESBLs) have emerged as the most common type of ESBL globally, their incidence easily surpassing those of SHV and TEM ESBLs in most locales. This study compared...Full Text Available

2010-01-01

231

Data of spleen-scintiscanning after splenectomy  

International Nuclear Information System (INIS)

In 65 adult rabbits of both sexes (2.5 to 6 kg) the following salvaging procedures were performed after simulated trauma: (1) Continuous suture line; (2) closure with fibrin sealant after temporary clamping; (3) hemisplenectomy with omental wrap; (4) suture fixation of fragments and slices of spleen tissue to the peritoneum; (5) suture fixation of spleen fragments to the omentum; (6) extraperitoneal subcutaneous transposition of spleen cubes. In addition, the likelihood of spontaneous splenosis was examined in a preliminary study involving 5 animals by introducing unattached spleen meal and fragments. Scanning was repeated 4 to 12 weeks postoperatively. The functional competence of minor parenchymal islands was also investigated with well counter measurements of organ and muscle tissue homogenates. Spontaneous splenosis after abdominal injuries was not found to be the rule. Salvaging procedures at the natural vascular hilus by sutures, fibrin sealant and ...

232

Computed tomography of the urinary bladder. Clinical application of the olive oil-filled method  

Energy Technology Data Exchange (ETDEWEB)

Out of one hundred cases of the urinary bladder abnormalities examined by this method, CT staging and pathological correlations were investigated in 61 cases of the urinary bladder neoplasms. Accuracy of CT staging was 87% in this series with possible exception of 6 cases involving the bladder base and dome. CT scan using this method is the most reliable procedure to determine the treatment modalities of the urinary bladder tumors.

1982-01-01

233

CT scan findings in cerebral paragonimiasis  

International Nuclear Information System (INIS)

Computed tomography was performed on 5 patients with chronic cerebral paragonimiasis. CT showed solitary or multiple, amorphous, round, or oval calcifications, and ventricular enlargement in all 5 cases. A large low-density area is also found in 4 of the 5 cases. These CT findings are compatible with previously reported findings of simple X-ray films of the skull, pneumoencephalography, and pathological studies. (author).

1982-01-01

234

CT manifestations of ileal dysgenesis  

Energy Technology Data Exchange (ETDEWEB)

Ileal dysgenesis is an uncommon condition of unknown etiology occurring in the distal ileum in the region of the vitelline duct. The CT appearance of this lesion, although not previously described to our knowledge, is characteristic. We report a patient with ileal dysgenesis who had an abdominal CT scan to evaluate chronic iron deficiency anemia and protein-losing enteropathy. Recognition of this lesion by pediatric radiologists is important; so that surgical treatment, which is simple and effective, can be initiated quickly. (orig.)

2007-02-15

235

Biodegradability of polyurethane/polysaccharide blends  

Energy Technology Data Exchange (ETDEWEB)

Biodegradable polymers for use in environmental waste-management has been the subject of much discussion over the last few years. Polyurethane mixtures with polysaccharide (80/20 and 90/10 w/w ) have been prepared and films obtained. These films were inoculated, according to ASTM G22-76 rule and analysed by thermogravimetry and scanning electronic microscopy (SEM). The results are discussed in terms of thermal degradation and biodegradability. (author)

2001-07-01

236

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the ...

2009-03-01

237

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning method. The focus is on examining how to increase the quality of the measured data. How to decrease the ...

2007-06-15

238

A study of the effect of Yttria additions on densification of #beta#-sialon  

International Nuclear Information System (INIS)

In this paper the effect of adding commercially pure yttria concentrate and yttrium carbonate concentrate (NUCLEMON) on the densification of #beta#-Sialon has been studied. The specimens were sintered in graphite furnace at 1720 and 175 deg C, for 1 hour in a nitrogen atmosphere. Densities of up to 99% of the theoretical density were obtained. Microstructural analyses of the specimens were carried out with the aid of an X ray diffractometer and a scanning electron microscope. (author)

1995-06-10

239

Application of low-dose radiation protocols in survey CT scans  

International Nuclear Information System (INIS)

Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for ...

2009-08-01

240

Use of x-ray imaging for evaluation of superconducting ceramics fabricated by PIT method  

Energy Technology Data Exchange (ETDEWEB)

High-spatial-resolution microfocus-based X-ray imaging technology, both real-time and film, has been used to study the thickness variation that occurs in the oxide core of silver-sheathed BSCCO ribbons produced by the powder-in-tube method. This thickness variation (also called ``sausaging``) occurs during incremental rolling and degrades the critical current densities of the ribbons. Using X-ray image data the authors determined the onset and severity of sausaging. Onset occurred at a ribbon thickness of 203 {micro}m, and the severity increased with subsequent rolling reductions. Scanning electron microscopy was used to confirm the X-ray image data. X-ray imaging provides several advantages over more traditional methods for characterizing the superconductors such as optical or scanning electron microscopy. The X-ray imaging provides nondestructive information about the entire width of the ribbon, with far greater speed, lower cost, and more ...

1993-08-01

241

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, irradiation temperature and ...

2008-10-01

242

Study of the crystallographic architecture of corals at the nanoscale by scanning transmission X-ray microscopy and transmission electron microscopy.  

Science.gov (United States)

We have investigated the nanotexture and crystallographic orientation of aragonite in a coral skeleton using synchrotron-based scanning transmission X-ray microscopy (STXM) and transmission electron microscopy (TEM). Polarization-dependent STXM imaging at 40-nm spatial resolution was used to obtain an orientation map of the c-axis of aragonite on a focused ion beam milled ultrathin section of a Porites coral. This imaging showed that one of the basic units of coral skeletons, referred to as the center of calcification (COC), consists of a cluster of 100-nm aragonite globules crystallographically aligned over several micrometers with a fan-like distribution and with the properties of single crystals at the mesoscale. The remainder of the skeleton consists of aragonite single-crystal fibers in crystallographic continuity with the nanoglobules comprising the COC. Our observation provides information on the nm-scale processes that led to biomineral formation in this ...

2011-05-05

243

Study of porous silicon morphologies for electron transport  

International Nuclear Information System (INIS)

Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the <100> crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns verified that bulk porous silicon is still a ...

1993-05-17

244

Sol-gel coatings with phosphonate functionalities for surface modification of magnesium alloys  

International Nuclear Information System (INIS)

Hybrid organic-inorganic coatings with phosphonate functionalities have been synthesized and evaluated as prospective surface treatments for magnesium materials. These coatings have been processed via a sol-gel route by hydrolysis and condensation of a mixture of diethylphosphonatoethyltriethoxy-silane and tetraethoxy-silane with variable molar ratios. The coatings morphology and the surface chemistry at the coating/substrate interface have been characterized using scanning electron microscopy, X-ray photoelectron spectroscopy, "3"1P nuclear magnetic resonance spectroscopy, and time-of-flight secondary ion mass spectrometry. The corrosion protection performance of the coatings deposited on magnesium alloy AZ31B has been examined by a group of electrochemical techniques including potentiodynamic polarization and electrochemical impedance spectroscopy. In addition, a scanning Kelvin probe technique has been used to investigate interfacial ...

2006-08-30

245

Scintiscanning with aerosols of "9"9Tc"m DTPA in the diagnostic strategy for pneumocystosis in aids patients  

International Nuclear Information System (INIS)

Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An examination with normal findings can therefore exclude the ...

1988-08-15

246

Role of "9"9"mTc sulfur colloid scintigraphy in differentiating non-cirrhotic portal fibrosis from cirrhosis liver  

International Nuclear Information System (INIS)

Two most important causes of portal hypertension are cirrhosis of liver and non-cirrhotic portal fibrosis (NCPF). The purpose of this study was to assess the scintigraphic appearances of "9"9"mTc sulfur colloid liver scan in differentiating liver cirrhosis from NCPF. Materials and Methods: Retrospective analysis records of 146 patients (91 male and 55 female) with diffuse hepatocellular disease was done for liver size, liver uptake, spleen size, spleen uptake, colloid shift to bone marrow and lungs. Results: Cirrhotic livers showed patchy and lower uptake than NCPF (59% vs. 20%, P-value 0.041). Spleen size was significantly increased in NCPF compared to cirrhosis (100% vs. 67%, P-value 0.0137). Significant colloid shift to bone marrow was noted in cirrhosis (84% vs. 7%, P-value<0.0001). Conclusion: "9"9"mTc sulfur colloid liver scan is a non-invasive procedure having a useful adjunctive role in clinical differentiation of cirrhosis from ...

247

Reconstruction of the activity of point sources for the accurate characterization of nuclear waste drums by segmented gamma scanning  

International Nuclear Information System (INIS)

This work improves the reliability and accuracy in the reconstruction of the total isotope activity content in heterogeneous nuclear waste drums containing point sources. The method is based on #chi#"2-fits of the angular dependent count rate distribution measured during a drum rotation in segmented gamma scanning. A new description of the analytical calculation of the angular count rate distribution is introduced based on a more precise model of the collimated detector. The new description is validated and compared to the old description using MCNP5 simulations of angular dependent count rate distributions of Co-60 and Cs-137 point sources. It is shown that the new model describes the angular dependent count rate distribution significantly more accurate compared to the old model. Hence, the reconstruction of the activity is more accurate and the errors are considerably reduced that lead to more reliable results. Furthermore, the results are compared to the ...

2011-06-01

248

Preparation, characterization and properties of thermochromic tungsten-doped vanadium dioxide by thermal reduction and annealing  

International Nuclear Information System (INIS)

Thermochromic tungsten-doped vanadium dioxide (VO2) powders were successfully synthesized by thermal reduction using V2O5 as a vanadium precursor. The products were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and differential scanning calorimetry (DSC). The results indicated that W was successfully doped into the crystal lattice of VO2 matrix, and prepared tungsten-doped VO2 had a rod-like morphology. The effects of reducing temperature and annealing temperature on the crystallographic structures were also discussed. The phase transition temperature (Tt) of VO2 could be simply tuned by changing the doping concentration of tungsten. When the doping concentration was 1.58 mol%, the Tt could be reduced to 37.8 oC from initial 69.5 oC, suggesting that tungsten-doped VO2 possesses prominent thermochromic properties and optical switching characters. It has shown that this ...

2010-08-20

249

Preparation of ZnO varistors by solution nano-coating technique  

Energy Technology Data Exchange (ETDEWEB)

This paper introduces a new method to produce nano-composite powder for the preparation of high performance ZnO varistors. ZnO particles were coated with Bi{sub 2}O{sub 3}, Sb{sub 2}O{sub 3}, Co{sub 2}O{sub 3}, Cr{sub 2}O{sub 3} and other additives via liquid nano-coating technique. Then the prepared powder was characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), thermal gravity and differential scanning calorimetry (TG-DSC) and particle size distribution. The results showed that the ZnO composite powder is homogeneously coated and ultrafine. The densification, phase composition and microstructure of ZnO varistors was studied by linear shrinkage, X-ray diffraction (XRD) and SEM, respectively. The preliminary electrical parameters of ZnO varistors showed that the breakdown voltage V {sub b} (1 mA/cm{sup 2}) and nonlinear coefficient {alpha} is 5400 V/cm and 50, respectively, much higher than that of ...

2006-06-15

250

Prediction of stable long-period superstructures in Cu-Pd, Ag-Pd and Au-Pd within a first-principles approach  

Energy Technology Data Exchange (ETDEWEB)

One- and two-dimensional long-period superstructures (LPS), based on the L1{sub 2} substructure, are systematically investigated for the noble metal-palladium alloys Cu-Pd, Ag-Pd and Au-Pd with first-principles methods. Notwithstanding the fact that the experimental phase diagrams of these systems yield totally different features, quite similar behaviour with respect to formation of low temperature ordered LPS-phases (Cu{sub 3}Pd: LPS 3, Ag{sub 3}Pd: LPS 3, Au{sub 3}Pd: LPS 2; {l_brace}Cu, Au{r_brace}Pd{sub 3}: L1{sub 2}, AgPd{sub 3}: not a ground state) is predicted. As a lever between via LDA obtained formation enthalpies and a thorough ground state scan, the cluster expansion method in conjunction with a genetic algorithm provides adequate means for the extraction of effective interactions, which also allow for an enhanced ground state scan in the configurational space of LPS structures. As a result, the sequences and energetical hierarchies ...

2007-07-01

251

Physico-chemical, optical and electrochemical properties of iron oxide thin films prepared by spray pyrolysis  

International Nuclear Information System (INIS)

Iron oxide thin films were prepared by spray pyrolysis technique onto glass substrates from iron chloride solution. They were characterized by X-ray diffractometry (XRD), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and (UV-vis) spectroscopy. The films deposited at T _s #<=# 450 deg. C were amorphous; while those produced at T _s_u_b = 500 deg. C were polycrystalline #alpha#-Fe_2O_3 with a preferential orientation along the (1 0 4) direction. By observing scanning electron microscopy (SEM), it was seen that iron oxide films were relatively homogeneous uniform and had a good adherence to the glass substrates. The grain size was found (by RX) between 19 and 25 nm. The composition of these films was examined by X-ray photoelectron spectroscopy and electron probe microanalysis (EPMA). These films exhibited also a transmittance value about 80% in the visible and infrared range. The cyclic voltammetry study showed ...

2006-12-15

252

Pelvic CT for the prognostic evaluation of anorectal malformation  

International Nuclear Information System (INIS)

The anatomical patterns of anorectal malformations have so far been studied according to the principles which inspire Pena's technique for the surgical treatment of anorectal anomalies. Thus, the diagnostic study of anorectal malformation has by the authors been considered a work of classification, but of identification. Among the diagnostic procedures in use in author's Institute, preoperative CT of pelvis is performed to assess the presence and to define the development of muscular sphincteric structure towards prognostic evaluation of continence, the major long-term goal. Seven patients, aged 1-30 months, with anorectal anomalies were studied with preoperative CT of the pelvis. CT scans showed well-developed sphinteric muscles in 3 patients (2 with recto-ureteral and 1 with recto-vestibular fistulas), poorly-developed muscular structure in 3 patients (with recto-vaginal, cloacal and prostatic fistulas), absence of muscular structure in 1 case (with recto-vesical ...

1989-01-01

253

Optimal alignment of mirror based pentaprisms for scanning deflectometric devices  

Science.gov (United States)

In the recent work [Proc. of SPIE 7801, 7801-2/1-12 (2010), Opt. Eng. 50(5) (2011), in press], we have reported on improvement of the Developmental Long Trace Profiler (DLTP), a slope measuring profiler available at the Advanced Light Source Optical Metrology Laboratory, achieved by replacing the bulk pentaprism with a mirror based pentaprism (MBPP). An original experimental procedure for optimal mutual alignment of the MBPP mirrors has been suggested and verified with numerical ray tracing simulations. It has been experimentally shown that the optimally aligned MBPP allows the elimination of systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of the bulk pentaprism. In the present article, we provide the analytical derivation and verification of easily executed optimal alignment algorithms for two different designs of mirror based pentaprisms. We also provide an analytical description for the mechanism for reduction of the systematic ...

2011-03-04

254

Morphology and thermal properties of electrospun fatty acids/polyethylene terephthalate composite fibers as novel form-stable phase change materials  

Energy Technology Data Exchange (ETDEWEB)

The ultrafine fibers based on the composites of polyethylene terephthalate (PET) and a series of fatty acids, lauric acid (LA), myristic acid (MA), palmitic acid (PA), and stearic acid (SA), were prepared successfully via electrospinning as form-stable phase change materials (PCMs). The morphology and thermal properties of the composite fibers were studied by field emission scanning electron microscopy (FE-SEM) and differential scanning calorimetry (DSC), respectively. It was found that the average fiber diameter increased generally with the content of fatty acid (LA) in the LA/PET composite fibers. The fibers with the low mass ratio maintained cylindrical shape with smooth surface while the quality became worse when the mass ratio is too high (more than 100/100). Moreover, the latent heat of the composite fibers increased with the increase of LA content and the phase transition temperature of the fibers have no obvious variations compared with ...

2008-11-15

255

Monte-Carlo simulations of 2-MeV #alpha#-particle channeling in Si_1_-_xSn_x alloy  

International Nuclear Information System (INIS)

Monte-Carlo simulations of 2-MeV #alpha#-particle channeling in Si_1_-_xSn_x alloys with 0#<=#x#<=#1 have been performed. The simulations are compared with measured channeling-angular scans for strained Si_0_._9_5Sn_0_._0_5 layers grown by molecular beam epitaxy (MBE). Agreement between simulated and measured angular scans can only be achieved if we assume a deviation of the crystal structure from the ideal one. This deviation can be attributed to a mosaic structure in the films and to an atomic-scale distortion of the crystal lattice due to an expected difference in the bond lengths between the Si-Si, Si-Sn and Sn-Sn atoms (such a difference in bond lengths has been observed in the epitaxial Si_1_-_xGe_x system). The contributions from both of these imperfections are estimated and discussed.

2000-04-01

256

Modification of SGS system for application to various sized drums  

Energy Technology Data Exchange (ETDEWEB)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The ...

2005-11-15

257

Modification of SGS system for application to various sized drums  

International Nuclear Information System (INIS)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is below 30 %. The accuracy of TGS is better ...

2005-11-01

258

MicroDiffraction in the Scanning Electron Microscope (SEM)  

Science.gov (United States)

The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification images, BEKP`s, and elemental information to ...

1997-12-31

259

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.

2001-05-01

260

Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose  

Energy Technology Data Exchange (ETDEWEB)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ueberlegen. Ebenso wurde ein hoeherer Bildkontrast bei der ...

1994-12-31

261

Kinetic investigations of graft copolymerization of sodium styrene sulfonate onto electron beam irradiated poly(vinylidene fluoride) films  

Energy Technology Data Exchange (ETDEWEB)

Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate grafts in the obtained membranes were observed by Fourier transform infrared (FTIR) spectroscopic analysis, ...

2011-01-15

262

Intrapartum FHR monitoring and neonatal CT brain scan  

Energy Technology Data Exchange (ETDEWEB)

The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with prolonged bradycardia and ...

1982-12-01

263

Intrapartum FHR monitoring and neonatal CT brain scan  

International Nuclear Information System (INIS)

The effect of fetal distress on the neonatal brain was investigated by neonatal CT brain scan, FHR monitoring and mode of delivery. This study involved 11 cases of full term vertex delivery in which FHR was recorded by fetal direct ECG during the second stage labor. All infants weighed 2,500 g or more. FHR monitoring was evaluated by Hon's classification. Neonatal brain edema was evaluated by cranial CT histgraphic analysis (Nakada's method). 1) Subdural hemorrhage was noted in 6 of 7 infants delivered by vacuum extraction or fundal pressure (Kristeller's method). 2) Intracranial hemorrhage was demonstrated in all of 3 infants with 5-min. Apgar score 7 or less. 3) Two cases with prolonged bradycardia and no variability had intraventricular or intracerebral hemorrhage which resulted in severe central nervous system damage. 4) The degree of neonatal brain edema correlated with 5-min. Apgar score. 5) One case with prolonged bradycardia and no variability resulted in ...

1982-01-01

264

High resolution scanning electron microscopy of plasmodesmata.  

Science.gov (United States)

Symplastic transport occurs between neighbouring plant cells through functionally and structurally dynamic channels called plasmodesmata (PD). Relatively little is known about the composition of PD or the mechanisms that facilitate molecular transport into neighbouring cells. While transmission electron microscopy (TEM) provides 2-dimensional information about the structural components of PD, 3-dimensional information is difficult to extract from ultrathin sections. This study has exploited high-resolution scanning electron microscopy (HRSEM) to reveal the 3-dimensional morphology of PD in the cell walls of algae, ferns and higher plants. Varied patterns of PD were observed in the walls, ranging from uniformly distributed individual PD to discrete clusters. Occasionally the thick walls of the giant alga Chara were fractured, revealing the surface morphology of PD within. External structures such as spokes, spirals and mesh were observed surrounding the PD. ...

2011-05-28

265

Hanaro fuel gamma scanning  

Energy Technology Data Exchange (ETDEWEB)

One bundle of Hanaro fuel irradiated up to 50%-burnup and cooled for 6 months was transported to IMEF for PIE, which has 6 elements. At first we measured the longitudinal distribution and the rotational distribution of several dominant peaks intensities from the bundle. After dismantling of the bundle we measured the longitudinal distribution of {sup 137}Cs and {sup 134}Cs peaks in each fuel element to see the burn-up feature. And finally we found out the relative number distribution of {sup 137}Cs and {sup 134}Cs for each detection point, which would be used for burn-up calculation. The relative detection efficiency of the scanning system was obtained experimentally by using the {sup 134}Cs peaks. We also checked up the azimuthal difference of peak intensity for each element, which are resulted about 2% of difference. These data will be used for the further analysis of Hanaro fuel performance evaluation. (author)

1999-09-01

266

Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring  

International Nuclear Information System (INIS)

A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.

267

Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube  

International Nuclear Information System (INIS)

This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor ...

1985-04-25

268

Evaluation of heterogeneity in thickness of passive films on pure iron by scanning electrochemical microscopy  

Energy Technology Data Exchange (ETDEWEB)

Scanning electrochemical microscopy (SECM) was applied to evaluate the heterogeneity of a passive film formed on a pure iron electrode in deaerated pH 8.4 borate solution. A probe current image of SECM was measured with a tip-generation/sub-strate-collection (TO/SC) mode in deaerated pH 8.4 borate solution containing 0.03 moldm{sup -3} Fe(CN){sub 6}{sup 4-} as a mediator. The difference in thickness of passive films formed on two iron plates at different potentials could be evaluated from the probe current image. The probe current image of the passivated iron surface with distinctive crystal grains was composed of the patch patterns, the shapes of which coincided completely with the shapes of the substrate crystal grains. The probe current flowed above the grain surface oriented to {l_brace}100{r_brace} plane was less than that above the grain surface oriented to {l_brace}110{r_brace} or {l_brace}111{r_brace} plane. The grain orientation dependence of probe current ...

1999-04-01

269

Effect of plasma nitriding on the properties of (Ti, Al)N coatings deposited onto hot work steel substrates  

Energy Technology Data Exchange (ETDEWEB)

The properties of polycrystalline (Ti, Al)N coatings deposited on non-nitrided, classically plasma-nitrided and low pressure plasma-nitrided AISI H11 steel samples were investigated. The plasma deposition and low pressure plasma nitriding were performed in a Z700-LH magnetron sputter ion plating unit, while a separate unit was used for plasma nitriding of specimens at a pressure of several millibars. The (Ti, Al)N coating was deposited onto all the samples using the same equipment as for the plasma deposition and low pressure plasma nitriding. For the characterization of the composite structures, the following methods were used: scratch test, X-ray diffraction analysis, scanning electron microscopy, scanning tunnelling microscopy and microhardness testing. It was found that plasma nitriding prior to coating deposition strongly affects the growth and properties of hard coatings, such as the microhardness, adhesion, preferred orientation, ...

1993-05-15

270

Donut-shaped high-dose configuration for proton beam radiation therapy  

Energy Technology Data Exchange (ETDEWEB)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which ...

2005-01-01

271

Donut-shaped high-dose configuration for proton beam radiation therapy  

International Nuclear Information System (INIS)

Background: the authors report on the conception and first clinical application of a donut-shaped high-dose configuration for proton therapy (PT). This approach allows one to intensify target volume dose coverage for targets encompassing a critical, dose-limiting structure - like here, the cauda equina -, whilst delivering minimal dose to other healthy structures surrounding the target, thereby reducing the integral dose. Methods and results: intensity-modulated PT methods (IMPT) for spot scanning were applied to create and deliver a donut-shaped high-dose configuration with protons, allowing treating > 75% of the target with at least 95% of the prescribed dose of 72.8 CGE, whilst restricting dose to the cauda equina to 60-65 CGE. Integral dose was lower by a factor of 3.3 as compared to intensity-modulated radiotherapy with photons (IMXT). Conclusion: IMPT and spot scanning technology allow a potentially clinically useful approach which is ...

2005-01-01

272

Direct patterning of gold oxide thin films by focused ion-beam irradiation  

International Nuclear Information System (INIS)

For direct writing of electrically conducting connections and areas into insulating gold oxide thin films a scanning Ar"+ laser beam and a 30 keV Ga"+ focused ion beam (FIB) have been used. The gold oxide films are prepared by magnetron sputtering under argon/oxygen plasma. The patterning of larger areas (dimension 10-100 #mu#m) has been carried out with the laser beam by local heating of the selected area above the decomposition temperature of AuO_x(130-150 C). For smaller dimensions (100 nm to 10 #mu#m) the FIB irradiation could be used. With both complementary methods a reduction of the sheet resistance by 6-7 orders of magnitude has been achieved in the irradiated regions (e.g. with FIB irradiation from 1.5 x 10"7#OMEGA#/#square# to approximately 6 #OMEGA#/#square#). The energy-dispersive X-ray analysis (EDX) show a considerably reduced oxygen content in the irradiated areas, and scanning electron microscopy (SEM), as well as atomic force ...

2000-09-01

273

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and CoR revealed the ...

1989-02-01

274

Diagnostic capability of digital radiography of the chest using scanning laser stimulated luminescence  

International Nuclear Information System (INIS)

Diagnostic capability of Fuji Computed Radiography (FCR) of the chest was compared to the conventional radiography (CoR) using regular film-screen system. FCR utilizers imaging plates of scanning laser stimulated luminescence. Visibility of 14 structures of the chest radiography was evaluated by 3 radiologists in 100 pairs of FCR and CoR which were taken at the same time with the same exposure factors. FCR was superior to CoR especially in observation of the mediastinum and areas behind the heart and diaphragm. The minor fissure was better seen on CoR. Superiority of FCR to CoR was thought to be mainly due to the processed image of FCR, and the so-called normal image of FCR had little diagnostic advantage. Simulated abnormal densities: nodular, alveolar, and interstitial densities with a chest phantom, were made, and detectability of alteration of these densities on FCR and CoR was evaluated by 19 radiologists, using ROC curve analysis. FCR and CoR revealed the ...

1989-01-01

275

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...

2006-12-01

276

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented ...

2009-12-01

277

Computer assisted axial tomography (Emi scan) in neurologic investigation  

Science.gov (United States)

Cerebral angiography, pneumoencephalography, and radioisotope brain scan with their differing diagnostic abilities have provided the neurologist and neurosurgeon with extremely valuable diagnostic techniques. It is doubtful, however, if any of these now conventional methods had the enormous impact on the practice of neurology that computer assisted axial tomography (C.A.T.) is beginning to have. Here, for the first time, is a test which, without significant risk or discomfort, can demonstrate some normal intracranial (and intraorbital) structures, can demonstrate some normal intracranial pathology and, in many cases, can make the potentially dangerous contrast studies unnecessary. After only a few months experience with C.A.T. in a clinical setting, it has become obvious that there will have to be a reappraisal of the accepted investigative work-up of many conditions. While it is too early to have formulated strict criteria for the use of C.A.T., this paper is an ...

1974-01-01

278

Combined Scanning Electron Microscope and Micro-InfraRed measurements on Interplanetary Dust Particles  

CERN Document Server

Laboratory characterization of Interplanetary Dust Particles (IDPs) collected in the lower stratosphere represents a concrete analysis of cosmic dust properties which played a fundamental role in the origin and evolution of Solar System. The IDPs were characterized by Field Emission Scanning Electron Microscope (FESEM) analyses and by InfraRed (IR) micro-spectroscopy. We present the FESEM images of six IDPs: three smooth grains, two porous and one a compact sphere. We also show the results of micro-IR transmission measurements on four IDPs that allowed us to identify their spectral class according to the criteria defined by Sandford and Walker. Only three of the analyzed particles show IR transmission spectra with a dominant "silicate absorption feature" so that they could be assigned to the three IR spectral classes: one has been classified as "amorphous olivine", one appears to be a mixture of "olivines" and "pyroxenes" and one belongs to the "layer-lattice ...

2007-01-01

279

Body dose conversion factors for computerized tomography  

International Nuclear Information System (INIS)

While there have been many experimental and calculational investigations on absorbed dose distribution in the patient resulting from conventional X-ray procedures, such data for computerized tomography (CT) are still sparse. As this diagnostic procedure has shown a rapid increase in application during recent years, we have determined absorbed dose to body organs in a human phantom resulting from CT examinations. The exposure model consists of the heterogeneous MIRD-5 phantom and a suitable Monte-Carlo method to calculate absorbed dose to organs of interest. The exposure conditions are specified according to the exposure specifications of a CT-scanner currently in use. The calculations cover the range of body tissues of interest in terms of organ absorbed doses as well as a risk weighted absorbed dose. A detailed example showing the calculation of red bone marrow dose is given and a somatic effective dose equivalent Hsub(ES) is calculated for different conventional and ...

1980-10-31

280

Three-dimensional cranio-facial computed tomography  

International Nuclear Information System (INIS)

Computed tomography allows today to reconstruct three-dimensional (eD) images fram axial scans. The authors report their experience in cranio-facial pathology achived in two Departments of Radiology (University of Trieste, Italy and University of Standford, California). 3D images have been realized using two different softwares, one of which allows to reconstruct both soft tissue and bone structures. The application in maxillo-facial traumas, cranio-facial malformations and head tumours are disscussed. 3D images turned out to be very useful for the optimal visualization and for the spatial demostration of the lesion and have potential applications in cranio-facial surgery and radiotherapy.

1986-01-01

281

Thermodynamics of potassium diclofenac salt aqueous solutions at various temperatures  

British Library Electronic Table of Contents (United Kingdom)

Solution and dilution enthalpies of aqueous solutions of potassium diclofenac salt (K_DC) were measured by an isoperibolic calorimeter at 298.15 and 318.5?K. Heat capacities of the solutions with concentrations 0.002?0.09?mol?kg?1 were obtained at the temperature interval of 288.15?318.15?K using a scanning adiabatic microcalorimeter. The virial coefficients were derived from Pitzer?s model, and the excess thermodynamic functions of both the solvent and the solute of the solution were calculated. The concentration and temperature dependencies of thermodynamic characteristics of the solution were analyzed and discussed.

2011-01-01

282

Temperature measurements via narrow line laser absorption of carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

Theoretical development for temperature measurements via narrow line, infrared absorption of carbon dioxide (CO{sub 2}) is presented. The proposed technique is based on rapid-scanning of two adjacent absorption line shapes. Spectroscopic considerations for sensitivity to temperature measurements are discussed. Several line pairs are evaluated, and the R(58) and R(60) transitions of the (00{sup 0}1){l_arrow}(00{sup 0}0) band are suggested for use in high temperature measurements for combustion systems.

1996-12-31

283

Submonolayer nucleation and growth and the initial stage of multilayer kinetic roughening during Ag/Ag (100) homoepitaxy  

Energy Technology Data Exchange (ETDEWEB)

A comprehensive Scanning Tunneling Microscopy (STM) study of submonolayer nucleation and growth of 2D islands in Ag/Ag(100) homoepitaxy for temperature between 295K and 370K is presented. The initial stages of multilayer kinetic roughening is also studied. Analysis of an appropriate model for metal (100) homoepitaxy, produces estimates of 350 meV for the terrace diffusion barrier, 400 meV for the adatom bond energy, and 25 meV for the additional Ehrlich-Schwoebel step-edge barrier.

1996-08-01

284

Study of penetration depth for V"+ with low energy implanted in peanut seeds  

International Nuclear Information System (INIS)

The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95

2002-11-01

285

Sonography and Computed Tomography in the evaluation of giant Baker's cysts  

International Nuclear Information System (INIS)

The US study of the posterior compartment of the knee usually allows the clinical suspicion of popliteal cyst to be confirmed. Neverthless, in case of giant Baker's cysts - which are, at any rate, less frequent -US diagnosis is more difficult. CT can help determine the benign nature of the lesion, and hallow an accurate spatial evaluation. Moreover CT, when accurately performed, demonstrates the caudal or cranial cystic spread, together with its clear separation from adjacent muscular tissues. Direct coronal scans are more useful to obtain better spatial definition than reformatted images.

1991-01-01

286

Solution-chemical syntheses of nanostructure HgTe via a simple hydrothermal process  

International Nuclear Information System (INIS)

HgTe rod-shape composed of crystalline particles has been prepared by a hydrothermal method, and characterized by means of X-ray powder diffraction (XRD), scanning electron microscopy (SEM), and transition electron microscopy (TEM). The effects of capping agents, reductants, reaction temperatures, and reaction times on crystal structures and shapes of HgTe have been investigated. The results showed that the CTAB as capping agent plays a crucial role in the hydrothermal process. The synthesis procedure is simple and uses less toxic reagents than the previously reported methods.

2010-06-04

287

Smart Acquisition EELS  

Energy Technology Data Exchange (ETDEWEB)

Electron energy loss (EEL) spectroscopy and high angle annular dark field (HAADF) imaging in aberration-corrected electron microscopes are powerful techniques to determine the chemical composition and structure of materials at atomic resolution. We have implemented Smart Acquisition, a flexible system of scanning transmission electron microsocpy (STEM) beam position control and EELS collection, on two aberration-corrected dedicated cold field emission gun (FEG) STEMs located at SuperSTEM, Daresbury Laboratory. This allows the collection of EEL spectra from spatially defined areas with a much lower electron dose possible than existing techniques such as spectrum imaging.

2010-07-01

288

Single parameter analysis of hysteretic magnetic flux trapping in high T{sub c} superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high {Tc} superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-10-01

289

Single parameter analysis of hysteretic magnetic flux trapping in high T_c superconductor ribbon  

International Nuclear Information System (INIS)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high T_c superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-07-19

290

Single parameter analysis of hysteretic magnetic flux trapping in high T[sub c] superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high [Tc] superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-01-01

291

Seismic and Rockphysics Diagnostics fo Multiscale Reservoir Textures  

Energy Technology Data Exchange (ETDEWEB)

We have continued to finish up our work on analyzing relationships between elastic properties and rock microstructure. We have worked on theoretical models for the effects of sorting and packing on elastic moduli and seismic velocities. After analyzing the scanning acoustic images of shales to quantify textures at different scales, we are now using theoretical inclusion models to quantify the elastic property variation with texture. In the closing phases of this project most of our efforts are now focused on writing up the results and preparing the final reports.

2005-02-01

292

Sample method for formation of nanometer scale holes in membranes  

Energy Technology Data Exchange (ETDEWEB)

When nanometer scale holes (diameters of 50 to a few hundred nm) are imaged in a scanning electron microscope (SEM) at pressures in the 10{sup -5} to 10{sup -6} torr range, hydrocarbon deposits built up and result in the closing of holes within minutes of imaging. Additionally, electron beam deposition of material from a gas source allows the closing of holes with films of platinum or TEOS oxide. In an instrument equipped both with a focused ion beam (FIB), and an SEM, holes can be formed and then covered with a thin film to form nanopores with controlled openings, ranging down to only a few nanometers.

2003-02-24

293

Role of positron emission tomography-computed tomography in staging and early chemotherapy response evaluation in children with neuroblastoma  

International Nuclear Information System (INIS)

To evaluate the role of positron emission tomography-computed tomography (PET-CT) in staging and determining early treatment response to chemotherapy in children with neuroblastoma (NB) and its correlation with the final outcome. Patients and Methods: Seventeen patients of NB with mean age of 51.5 months (age range 2-132 months; 14 males, 3 females) underwent serial "1"8F-fluorodeoxyglucose (FDG) PET-CT imaging. All 17 patients were for staging before any treatment. Twelve of 17 patients underwent "1"3"1I meta-iodobezylguanidine (MIBG) scan and bone scan. MIBG uptake was seen in the primary lesion in 11/12 patients. MIBG uptake in bones was seen in 3/12 patients. All bone lesions were concordant on MIBG and bone scan. Early response to chemotherapy was evaluated after two cycles using PET-CT. A 30% reduction in longest diameter was taken as cut-off value for response on CT based on the response evaluation criteria in solid ...

294

Resistance of radiation-induced tropical wood-polymer composites to fungal degradation  

Energy Technology Data Exchange (ETDEWEB)

The resistance of six tropical hardwoods to fungal degradation by two wild-type strains of Phanerochaete chrysosporium Burdsall was investigated using vermiculite burial and wood-block weight loss techniques. Radiation-induced wood-polymer composites (WPC), based on two hardwoods Ramin and Rubberwood with methyl methacrylate, were prepared, and samples were also exposed to the wood-rotting fungus. A significant improvement in resistance to fungal decay was observed in the WPC. Scanning-electron micrographs of the two woods and their composites after fungal degradation are presented and discussed.

1987-01-01

295

Radiodiagnosis of Ewing's sarcoma of the rib in children  

International Nuclear Information System (INIS)

The results of the examination of 23 children with Ewing's sarcoma of the rib were analyzed: panoramic chest X-rays in 4 projections, spot radiographs of the robs, superexposed pictures, laterograms, urography, angiography, computerized tomography, and scanning of the skeleton. Causes of diagnostic errors made at the first consultation by a physician, were identified. Peculiarities of X-ray signs of tumors of this site in children were studied. Diagnostic difficulties in tumors complicated by pleurisy and in tumors of small sizes with extrapleural growth were shown. Inclusions in the extraoseous tumor component were noted in 8.7% of the cases.

296

Precipitation, phase transformation, and enhanced diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

This paper describes Z-contrast scanning transmission electron microscopy used to study the connection between dopant precipitation and phase transformation in high dose In"+ and Sb"+ implanted Si. In the case of In, the observations confirm a heterogeneous nucleation model. Images of the precursor precipitates give the first measurement of the diffusion coefficient in amorphous Si, with an enhancement of 10"7 over tracer crystalline values. With Sb"+ implants enhanced homogeneous nucleation is observed. The connection between these results and the transient enhanced diffusion observed in crystallized Si is discussed.

297

Posttraumatic tibia valga: a case demonstrating asymmetric activity at the proximal growth plate on technetium bone scan  

Energy Technology Data Exchange (ETDEWEB)

Posttraumatic tibia valga is a well-recognized complication following fracture of the upper tibial metaphysis in young children. We present a case of a child who developed a valgus deformity following fracture of the proximal tibia and fibula in which quantitative bone scintigraphy at 5 months after injury demonstrated increased uptake at the proximal tibial growth plate with proportionally greater uptake on the medial side. This finding suggests that the valgus deformity in this patient was due to a relative increase in vascularity and consequent overgrowth of the medial portion of the proximal tibial physis.

1987-07-01

298

Posttraumatic tibia valga: a case demonstrating asymmetric activity at the proximal growth plate on technetium bone scan  

International Nuclear Information System (INIS)

Posttraumatic tibia valga is a well-recognized complication following fracture of the upper tibial metaphysis in young children. We present a case of a child who developed a valgus deformity following fracture of the proximal tibia and fibula in which quantitative bone scintigraphy at 5 months after injury demonstrated increased uptake at the proximal tibial growth plate with proportionally greater uptake on the medial side. This finding suggests that the valgus deformity in this patient was due to a relative increase in vascularity and consequent overgrowth of the medial portion of the proximal tibial physis.

299

Pitting corrosion of nickel base alloys in halide media  

International Nuclear Information System (INIS)

A computerized corrosion measuring system (EG and G model 350 A) was used to study the influence of Cr, Mo, Ti, Nb and W on the pitting corrosion of nickel base alloys in 3% NaCl at 90"0C. The electrochemical parameters under investigation are the corrosion potential E_c_o_r_r, pitting potential E_p and protection potential E_p_p. The corrosion behaviour of nickel base alloys were studied by using pitting scan and potentiostatic techniques. Values of corrosion potential, pitting potential and protection potential were used for a ranking of alloys for corrosion resistance.

1988-03-06

300

Nanocrystallization of the amorphous Fe_1_4Ni_4_0Zr_7B_1_2 alloys studied by the Moessbauer spectroscopy  

International Nuclear Information System (INIS)

Formation of the soft magnetic nanostructure in amorphous Fe_1_4Ni_4_0Zr_7B_1_2 alloy due to heat treatment is studied by the Moessbauer, differential scanning calorimetry, and X-ray diffraction techniques. Annealing at temperatures 520-580 "oC leads to the formation of extremely soft nanocrystalline alloy as revealed by the rf-Moessbauer measurements. The superparamagnetic behaviour was observed for the alloy annealed at 620-640 "oC. At higher annealing temperatures good soft magnetic properties deteriorate. (author)

2001-09-23

301

NMR at earth's magnetic field using para-hydrogen induced polarization  

British Library Electronic Table of Contents (United Kingdom)

A method to achieve NMR of dilute samples in the earth's magnetic field by applying para-hydrogen induced polarization is presented. Maximum achievable polarization enhancements were calculated by numerically simulating the experiment and compared to the experimental results and to the thermal equilibrium in the earth's magnetic field. Simultaneous 19F and 1H NMR detection on a sub-milliliter sample of a fluorinated alkyne at millimolar concentration (1018 nuclear spins) was realized with just one single scan. A highly resolved spectrum with a signal/noise ratio higher than 50:1 was obtained without using an auxiliary magnet or any form of radio frequency shielding.

2011-01-01

302

Mineral analysis in experimental corneal scars. An EDAX study  

Energy Technology Data Exchange (ETDEWEB)

Central penetrating excisional wounds were made in the corneas of 12 rabbits and 10 trout. The scar tissue and the surrounding cornea were compared using a new method for assessing inorganic elements in the cornea: the scanning electron microscopy and energy dispersive analysis of x-ray (EDAX). Semiquantitative determination of inorganic elements within the range of atomic numbers 9-93 in the periodic system was performed, comparing the relative concentration of those elements in the scar tissue to the surrounding cornea. Results showed that calcium was the only element higher in the healing wound than in the surrounding cornea.

1988-01-01

303

Low temperature latent heat thermal energy storage - heat storage materials  

Energy Technology Data Exchange (ETDEWEB)

Heat-of-fusion storage materials for low temperature latent heat storage in the temperature range 0-120 C are reviewed. Organic and inorganic heat storage materials classified as paraffins, fatty acids, inorganic salt hydrates and eutectic compounds are considered. The melting and freezing behavior of the various substances is investigated using the techniques of Thermal Analysis and Differential Scanning Calorimetry. The importance of thermal cycling tests for establishing the long-term stability of the storage materials is discussed. Finally, some data pertaining to the corrosion compatibility of heat-of-fusion substances with conventional materials of construction is presented.

1983-01-01

304

Influence of microalloying on the corrosion resistance of steel in saturated calcium hydroxide  

International Nuclear Information System (INIS)

The influence of microalloying vanadium or titanium on improving the corrosion resistance of mild steel in saturated calcium hydroxide solution was investigated. Potential-time, potentiodynamic polarization, and impedance measurement techniques were employed. The corrosion products have been examined by infrared and X-ray diffraction analysis and by scanning electron microscopy. It has been shown that the grain refining, due to microalloying, plays an important role in enhancing the corrosion resistance of steel. Scales of calcite and iron oxides on top of a protective oxide are formed on the investigated steels.

305

Imaging characterization of carbon nanotube tips modified using a focused ion beam  

International Nuclear Information System (INIS)

A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.

2007-06-15

306

Heat capacity measurement of some breeder materials  

International Nuclear Information System (INIS)

Isobaric molar heat capacities of powder and microsphere form of Li2TiO3 (s) and powder form of LiAlO2 (s) and Li2ZrO3 (s) were measured using a heat flux type differential scanning calorimeter in the temperature range 320 - 870 K. Specific heat capacities of LiAlO2 (s) was found to be much larger compared to those of Li2TiO3 (s) and Li2ZrO3 (s). (author)

2009-01-07

307

FCR (Fuji Computed Radiography) in neurosurgery  

Energy Technology Data Exchange (ETDEWEB)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness.

1988-08-01

308

FCR (Fuji Computed Radiography) in neurosurgery  

International Nuclear Information System (INIS)

As part of the evolution of computer technology, Fuji Computed Radiography (FCR) has been developed as a new system for radiographical diagnosis. In this system, the X-ray energy is stored on the imaging plate and then converted into digital signals utilizing scanning laser-stimulated luminence. After proper image processing, it offers much more improved information for diagnosis than the conventional film system does. Since April, 1986, we have principally used FCR (System 101) for neurosurgical practice. In this article, we present our recent experience and evaluate its usefulness. (author).

1988-01-01

309

Etching characteristics of high-purity aluminum in hydrochloric acid solutions  

Energy Technology Data Exchange (ETDEWEB)

We investigated the effects of additives to the etching solution of 1 M hydrochloric acid on the electrochemical etching behavior for aluminum electrolytic capacitors, using scanning and transmission electron microscopy, and AC impedance spectroscopy. For the addition of 1 M sulfuric acid or 5% ethylene glycol to the hydrochloric acid solution, the distribution of etch tunnels was more uniform with high density of etch pits compared with that without addition. The highest specific surface area was obtained from the electrolyte with 5% ethylene glycol additive. The correlation of internal morphologies of etched foils with impedance parameters was interpreted by impedance techniques.

2007-03-25

310

Employment of /sup 203/Pb isotoic solution without a carrier for erythrocyte tracing  

Energy Technology Data Exchange (ETDEWEB)

Possibilities of applying the Pb/sup 203/ isotonic solution without a carrier as a label of blood erythrocytes, are found. There is a number of advantages in the Pb/sup 203/ isotonic solution without a carrier, such as a high label efficiency (above 95%), a short half-life (52 hours), and a low radiation dose. These factors prove to be favourable as compared with Cr/sup 51/ widely used for these purposes. Besides, of all preparations used up to now to treat erythrocytes and to scan the spleen, it is only in the case of Pb/sup 203/ isotonic solution without a carrier that no weight amounts of chemical substances do not enter the organism.

1981-08-01

311

Electrochemical reduction of Yttrium ions. Technical report  

Energy Technology Data Exchange (ETDEWEB)

The cathodic electrode process of Y(3+) ions on the Mo electrode in the LICl-KCl molten salt with YCl3(3wt%) in the temperature range of 450 - 530 deg. C has been investigated using cyclic voltammetry and chronopotentiometry. The convolution technique has been applied to the treatment of cyclic voltammogram. The results show that the reduction mechanism of Y(3+) ion is Y(3+) + 3e = Y, a simple one-step process. The cathodic process is very close to a reversible process under lower scanning rates, and is diffusion-controlled. The cathodic product is an insoluble product.

1995-08-01

312

Effect of #alpha#-phase morphology and distribution on the tensile ductility of a metastable beta titanium alloy  

International Nuclear Information System (INIS)

In a program to develop a metastable beta alloy with improved fracture toughness, it was found that the tensile ductility of the alloy Ti-8 Mo-4.5 Cr-2.5 Al was strongly dependent on both processing history and annealing temperature. Evaluation of the microfracture mode of tensile samples by scanning electron microscope and metallographic techniques showed that the presence of a continuous grain boundary alpha is the most significant parameter controlling the ductility and is highly detrimental. It is concluded that, for optimum processing, the material must be worked prior to aging to avoid this grain boundary phase.

313

Development of a chemically assisted micro-beam etching system for three-dimensional microanalysis  

Energy Technology Data Exchange (ETDEWEB)

A chemically assisted micro-beam etching system for 3D microanalysis was designed. Using chemically assisted ion beam etching (CAIBE) method with FIB shave-off scanning, about several hundred micrometers clean cross-section will be acquired in a few hours. We use focused ion beam (FIB) and electron beam (EB) as micro-beams, halogen or halide mainly as reactive gases. The apparatus was manufactured based on this concept. We found that the FIB, Q-MS and SED worked as expected. The instrumentation has been completed.

2003-01-15

314

Conformal radiation therapy: technical requirements and clinical applications  

International Nuclear Information System (INIS)

Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.

1995-01-01

315

Computed Tomography of the cranio-cervical junction in rhematoid arthritis  

International Nuclear Information System (INIS)

Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.

1987-01-01

316

Compression, bend, and impact testing of some tropical wood-polymer composites  

International Nuclear Information System (INIS)

The compressive and bending strengths of a local tropical wood (Kapur-Dryobalanop sp.) were improved significantly by suitable impregnation of polymeric monomers (methylmethacrylate, methylmethacrylate - 5% dioxane and vinyl acetate) into the wood cellular structure and subsequent irradiation to form a wood-polymer composite. Statistical analysis revealed a linear relationship between increase in the strengths and the percentage of polymer impregnated. Fractographic analysis of the impact fractured surfaces under the scanning electron microscope showed the nature of the wood-polymer interface, which could account for the increase in the compressive and bending strengths. (author).

1985-01-01

317

Comparison of temperature and humidity profiles with elastic-backscatter lidar data  

Energy Technology Data Exchange (ETDEWEB)

This contribution analyzes elastic-backscatter lidar data and temperature and humidity profiles from radiosondes acquired in Barcelona in July 1992. Elastic-backscatter lidar data reveal the distribution of aerosols within the volume of atmosphere scanned. By comparing this information with temperature and humidity profiles of the atmosphere at a similar time, we are able to asses de relationship among aerosol distribution and atmospheric stability or water content, respectively. Comparisons have shown how lidar`s revealed layers of aerosols correspond to atmospheric layers with different stability condition and water content.

1995-04-01

318

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system  

International Nuclear Information System (INIS)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table movement, all ...

319

Boric acid effect in phenolic composites on tribological properties in brake linings  

International Nuclear Information System (INIS)

In the present work, using a pad-on-disc-type wear tester, the tribological properties of the pad next to the disk made of cast iron were investigated with changing the substance of the components. As well, micro-structural characterisation of braking pads was performed using scanning electron microscopy and also temperature outcome of the pads was examined at the temperatures of 50-400 "oC in the pressure of 1050 and 3000 kPa. Finally, the effect of environment to the pads was studied in water, salty water, oil and braking liquid media.

320

Bone scanning after muscle-pedicle bone graft for femoral neck fracture, (1). Preliminary report  

Energy Technology Data Exchange (ETDEWEB)

sup(99m)Tc-MDP bone scintigraphy was performed on patients who received muscle-pedicle bone graft. In each of the bone head and the bone graft, a time-activity curve was obtained. In this muscle-pedicle bone graft, active revascularization and marked osteogenesis, which suggested rapid bone repairing, were observed. The bone scintigraphy was considered to be useful in observing the result of bone grafts, blood circulation, and time of bone fusion, and of value for early detection of secondary changes.

1982-04-01

321

An integrated approach to the modelling of hydrogen assisted failure in 316L steel  

International Nuclear Information System (INIS)

An integrated approach to the modelling of hydrogen assisted failure in 316L steel is presented. The approach includes experimental, fractographic, numerical and theoretical analysis of the phenomenon. The physical adequacy of the mechanical models of hydrogen embrittlement (notch extension model and notch cracking model) is discussed by comparing the virtual damage depth (theoretical) predicted by the models with the embrittled zone (microphysical) measured in the fractographic analysis by scanning electron microscopy. In addition, a numerical modelling of hydrogen diffusion is performed, concluding that bulk diffusion is not important in hydrogen embrittlement of 316L steel, so that hydrogen transport accelerated by the microdamage itself should be taken into account. (orig.)

1998-09-01

322

Acid corrosion inhibition of copper by mangrove tannin  

British Library Electronic Table of Contents (United Kingdom)

Purpose - The purpose of this paper is to evaluate the corrosion inhibition potential of mangrove (Rhizopora apiculata) tannin in hydrochloric acid medium on copper with the view of developing a natural corrosion inhibitor. Design/methodology/approach - The mangrove tannin was extracted from the mangrove bark and its anticorrosion potential was studied by weight loss, electrochemical and scanning electron microscopy (SEM) analysis. Findings - It has been found that the mangrove tannin effectively inhibits the corrosion on copper metal in hydrochloric acid solution. The results of the electrochemical and weight loss methods showed that the inhibition efficiency of mangrove tannin increases with increasing its concentration. Inhibition is achieved through the adsorption of tannin molecules o...

2011-01-01

323

A high capacity, template-electroplated Ni-Sn intermetallic electrode for lithium ion battery  

British Library Electronic Table of Contents (United Kingdom)

In this paper we describe a Ni-Sn intermetallic material obtained via template electroplating synthesis. The structure and the morphology of this material are investigated by X ray diffraction (XRD) and Scanning Electron Microscopy (SEM) analyses. We demonstrate that Ni-Sn behaves as a sub-micrometric electrode showing a favourable response when cycled in a lithium cell. The results here reported suggest that the template electroplating is a promising synthetic approach that can lead to an optimized structure and morphology of the Ni-Sn electrode, such as to confer it a role of a high capacity anode in advanced lithium ion batteries.

2011-01-01

324

A correlation between electrochemical parameters and stress corrosion cracking of alloy 600 in high temperature caustic solution  

International Nuclear Information System (INIS)

The properties of the passive films formed on Alloy 600 at different applied potentials in 10% NaOH solution at 315 .deg. C was studied using in situ AC impedance and polarization measurements. The results were correlated with the stress corrosion cracking (SCC) behavior obtained from the C-ring tests in the same conditions. The change of the semiconductive property and the peak of relaxation time were observed at 0.2 V where the SCC rate showed a maximum. These results were also consistent with the prediction parameter for SCC obtained from fast and slow polarization scans.

2001-10-01

325

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

326

Smugglers masters as lobbying. Off scanner at the borders is a topic for politicians  

International Nuclear Information System (INIS)

Smugglers, who make use of the Ukraine-Slovak border for their business, might be satisfied after last week. The Slovak government ordered the switching off of scanning equipment monitoring the movement of goods by train through the Matovce border line. The modern equipment was substituted by people, who aren't able to check freight cars as effectively as gadgets. Not only in Ukraine are they celebrating this success in corruption, who demanded the shut-off of the scanning equipment The bosses on the Slovak side are also rubbing their hands. As told to TREND by Margareta Grecova, spokeswoman for Cargo Slovakia, 90% of goods that cross through the border at Matovce are unloaded. The most frequently transported commodities are ore, coal, chemical and petroleum products. Smugglers put their consignments among iron ore and coal. They prefer goods with high consumer taxes. Besides alcohol, there are mainly cigarettes. These are put into boxes which ...

2009-08-27

327

Serumal rate of the chromogranin in neuroendocrine tumor ET; Taux serique de la chromogranine a ET tumeurs neuroendocrines  

Energy Technology Data Exchange (ETDEWEB)

The intracellular A chromogranin (ACg) is specific in neuroendocrine cells. This work is a contribution to the study of clinical interest of serumal dosage of this protein in a series of patients carrying neuroendocrine tumors (NET). From January `94 to November `96, 143 patients were subjected to OctreoScan scintigraphy and/or to MIBG. In 104 of them a dosage of ACg by RIA method was effectuated. A study of a statistical relation was performed on the rate of ACg and histopathological, clinical and scintigraphic criteria. Analysis of results excluded the patients with abnormal creatininemy; it referred exclusively to the patients the histopathology of whose it was proved. The global results concerning the sensitivity and specificity of ACg are: 68% and 92%, respectively, for a threshold of normality at 100 ng/ml; 65% and/or 100% for a threshold at 110 ng/ml. There is a significant difference between the group of patients with NET (70 patients): 371 {+-} 59 ng/ml ...

1997-12-31

328

Rare-earth mixed oxide thin films as 100% lattice match buffer layers for YBa2Cu3O7-x coated conductors  

International Nuclear Information System (INIS)

Buffer layers with 100% lattice match with YBa2Cu3O7 - ? (YBCO) were prepared from mixed rare-earth-oxides applying a simple sol-gel process and dip-coating method. Structural analysis of the sol-gel derived powder by X-ray diffraction revealed that the mixing parameter, which eliminates the lattice mismatch with YBCO, is x = 0.2382, 0.1852, 0.1252, 0.0906, 0.0793 and 0.0395 in (Eu1 - xHox)2O3, (Eu1 - xErx)2O3, (Eu1 - xYbx)2O3, (Gd1 - xHox)2O3, (Gd1 - xYx)2O3 and (Gd1 - xYbx)2O3, respectively. Microstructural investigations were carried out for Gd1.819Ho0.181O3 films epitaxially grown on cube-textured Ni (100) substrates by sol-gel dip-coating process. X-ray diffraction of the buffer showed strong out-of-plane orientation on Ni tape. The (Gd1 - xHox)2O3 (222) pole figure indicated a single cube-on-cube textured structure. The omega and phi scans revealed good out-of-plane and in-plane alne alignments. The full-width at half-maximum values of omega and phi ...

2010-04-02

329

Intrahepatic peripheral cholangiocarcinoma; dynamic features of CT scans  

International Nuclear Information System (INIS)

To elucidate the dynamic features of CT scans in peripheral cholangiocarcinoma for the differentiation of this tumor from various primary hepatic neoplasms. Materials were 24 cases of pathologically confirmed peripheral cholangiocarcinoma. Contrast enhancement patterns of central and peripheral portion of the masses were analyzed at three phases including arterial dominant(22), tissue equilibria(24), and postequilibria(9). Other associated CT findings and laboratory data were analyzed. Serum total bilirubin was mostly below 2 mg/dl(22/24), hepatitis B surface antigen was positive in only 9%, serum alphafetoprotein was elevated in 18%, carcinoembryonic antigen in 47%, cancer antigen 19-9 in 60%. In the arterial dominant image(22), 50% of the cases showed peripheral hyperdensity and 50% total hypodensity. In the tissue equilibrial images(24), 63% showed total hypodensity, 25% peripheral hyperdensity, and 13% total isodensity. In the postequilibrial images(9), 45% ...

1995-05-01

330

In situ scanning tunneling microscope study of the passivation of Cu(111)  

Energy Technology Data Exchange (ETDEWEB)

In situ scanning tunneling microscopy has been used to study the nucleation and growth mechanisms and the structure of passive films formed on Cu(111) surfaces in 0.1 M borate buffer solution (pH 9.3). A surface topography characterized by terraces with monoatomic steps is obtained after potentiodynamic reduction down to {minus}1.12 V/standard hydrogen electrode (SHE), of the electropolished surface exposed to air. The formation of a single Cu{sub 2}O passive layer at 0.03 V/SHE proceeds first by a roughening of the steps assigned to a locally blocked step flow process due to a competition between dissolution and preferential nucleation of the oxide at the steps. The observed oxide nuclei are 2--3 nm wide and about one atomic plane high. This process leads to the complete coverage of the terraces by a grain-like structure of the oxide film. The initial terrace topography is completely altered. Thickening of this oxide layer leads to unstable ...

1999-02-01

331

Feasibility study of computed tomography colonography using limited bowel preparation at normal and low-dose levels study  

Energy Technology Data Exchange (ETDEWEB)

The purpose was to evaluate low-dose CT colonography without cathartic cleansing in terms of image quality, polyp visualization and patient acceptance. Sixty-one patients scheduled for colonoscopy started a low-fiber diet, lactulose and amidotrizoic-acid for fecal tagging 2 days prior to the CT scan (standard dose, 5.8-8.2 mSv). The original raw data of 51 patients were modified and reconstructed at simulated 2.3 and 0.7 mSv levels. Two observers evaluated the standard dose scan regarding image quality and polyps. A third evaluated the presence of polyps at all three mSv levels in a blinded prospective way. All observers were blinded to the reference standard: colonoscopy. At three times patients were given questionnaires relating to their experiences and preference. Image quality was sufficient in all patients, but significantly lower in the cecum, sigmoid and rectum. The two observers correctly identified respectively 10/15 (67%) and 9/15 ...

2007-12-15

332

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

Energy Technology Data Exchange (ETDEWEB)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second ...

2006-07-01

333

Eddy current array probe for detection of surface breaking cracks in the extrados of feeder bends  

International Nuclear Information System (INIS)

A new eddy current array probe has been implemented as a straightforward and promising technique for detection of outer diameter (OD) surface-breaking cracks on the extrados of feeder bends. The design is based on previous work performed at AECL, which had demonstrated that eddy current probes with laterally displaced transmit-receive coils can overcome some of the limitations of inspecting ferritic steel components for surface-breaking cracks. The Feeder Integrity Joint Program-CANDU Owners Group Inc. (FIJP-COG) Non-Destructive Evaluation (NDE) Team members commissioned AECL to work in collaboration with the probe manufacturer ZETEC, to develop a field usable eddy current array probe. The objective was to acquire a technique with the following capabilities: fast scanning non-contact inspection technique for surface breaking discontinuities; full inspection of the bend extrados OD surface in a single scan; ability to inspect first and second ...

2005-11-20

334

Different "1"8F-FDG Uptake According to Tumor Location and Morphology of Cholangiocarcinoma and Its Clinical Implication  

International Nuclear Information System (INIS)

"1"8F-fluorodeoxyglucose (FDG) uptake on positron emission tomography (PET) scan has been found to reflect tumor aggressiveness and prognosis in various types of cancer. However, pattern of FDG uptake in biliary malignancies and its clinical significance have not been studied well. The purpose of this study was to assess the additional value of "1"8F-FDG PET in differential diagnosis and prognosis of cholangiocarcinoma (CC) according to the tumor location and tumor morphology. From April 2005 to May 2008, eighty two patients (M:F=55:27, age 66.2#+-#9.6 yrs) with CC underwent "1"8F-FDG PET. For semiquantitative analysis, the maximum standardized uptake value (SUV_m_a_x) was obtained from the primary tumor. The difference of SUV_m_a_x according to the tumor location and tumor growth pattern, such as scirrhous type, nodular type, polypoid type were compared. Overall sensitivity of PET scan was 81.7% in CC. SUV_m_a_x on PET ...

2009-08-01

335

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma ...

2003-10-01

336

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

International Nuclear Information System (INIS)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection efficiency of gamma scanning system for 1 MeV ...

2003-10-01

337

A New Approach to Studying Biological and Soft Materials Using Focused Ion Beam Scanning Electron Microscopy (FIB SEM)  

International Nuclear Information System (INIS)

Over the last decade techniques such as confocal light microscopy, in combination with fluorescent labelling, have helped biologists and life scientists to study biological architectures at tissue and cell level in great detail. Meanwhile, obtaining information at very small length scales is possible with the combination of sample preparation techniques and transmission electron microscopy (TEM) or scanning transmission electron microscopy (STEM). Scanning electron microscopy (SEM) is well known for the determination of surface characteristics and morphology. However, the desire to understand the three dimensional relationships of meso-scale hierarchies has led to the development of advanced microscopy techniques, to give a further complementary approach. A focused ion beam (FIB) can be used as a nano-scalpel and hence allows us to reveal internal microstructure in a site-specific manner. Whilst FIB instruments have been used to study and ...

2006-02-22

338

The role of 3D Helical CT in the reconstructive treatment of maxillofacial cancers  

International Nuclear Information System (INIS)

Purpose of this work is to investigate the role of Helical CT and the usefulness of three-dimensional (3D) imaging for pre-operative planning and follow-up of reconstructive maxillofacial surgery with alloplastic material in neoplastic disease involving this region. From 1996 to 1999 eleven patients were examined with Helical CT and 3D images for planning of maxillofacial plastic and reconstructive surgery for advanced cancer of this anatomically complex region. A 3D-modulated titanium mesh (100%) or micro nets was used to rebuild the anterior surface of maxillary bone and the orbital floor. The mesh was cut to the appropriate size and shape and curved where necessary. Within the residual sinusal cavity a siliconed filling was used surmounting an acrylic prosthesis with dental arch to rebuild the palate. A rehydrated bovine pericardium was affixed and moduled on the borders in two cases only. Three-dimensionally reconstructed CT images were obtained preoperatively and at least 6 months ...

2000-12-01

339

Clinically silent heterotaxy with polysplenia syndrome and IVC azygous continuation draining to SVC: CT findings. Case report  

International Nuclear Information System (INIS)

Patients with heterotaxy syndrome often have complex cardiac and extracardiac anomalies requiring further detailed diagnostic evaluation. They often present severe cardiac failure early in life. Newer radiological modalities in the form of spiral computed tomography (CT) and three-dimensional reconstruction of spiral CT allow clear definition of the anatomy of these anomalies. A 59-year-old woman was diagnosed with polysplenia and multiple anomalies in an abdominal ultrasonography (US) during a control medical examination due to a trivial dietary mistake. She was then referred to our institution for further examination of these anomalies and an additional thoraco-abdominal computed tomography (CT) examination. The patient was totally asymptomatic at the time of admission. There was no significant past history and no abnormal laboratory data. We performed abdominal, pelvic and thoracic CT examinations using Somatom Siemens Emotion scanner. Non-enhanced sections were obtained with 8 mm ...

2007-01-01

340

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the ...

2007-08-21

341

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. Many of the design features and the end ...

2007-08-21

342

X-ray Microdiffraction and Strain Gradient Crystal Plasticity Studies of Geometrically Necessary Dislocations Near a Ni Bicrystal Grain Boundary  

Energy Technology Data Exchange (ETDEWEB)

We compare experimental measurements of inhomogeneous plastic deformation in a Ni bicrystal with crystal-plasticity simulations. Polychromatic X-ray microdiffraction, orientation imaging microscopy and scanning electron microscopy, were used to characterize the geometrically necessary dislocation distribution of the bicrystal after uniaxial tensile deformation. Changes in the local crystallographic orientations within the sample reflect its plastic response during the tensile test. Elastic strain in both grains increases near the grain boundary. Finite element simulations were used to understand the influence of initial grain orientation and structural inhomogeneities on the geometrically-necessary dislocations arrangement and distribution and to understand the underlying materials physics.

2009-01-01

343

Water-repellency and antibacterial activities of plasma-treated cleavable silicone surfactants on nylon fabrics  

British Library Electronic Table of Contents (United Kingdom)

In this paper we describe how cleavable surfactants decompose into water-insoluble silanols and two water-soluble products when subjected to vacuum plasma treatment. We used Raman spectroscopic analysis to confirm these structural changes, and we performed contact angle measurements and employed scanning electron microscopy to observe the surface morphologies of these compounds. Our contact angle measurements confirm that the products had degraded on nylon fabrics during argon gas plasma treatment. All of the PEG-silicone polyesters displayed excellent water-repellency; PEG6000-silicone exhibited the largest contact angle (130?) and, hence, the greatest water-repellency. Our results indicate that the silanols that form upon plasma treatment may be useful in coatings applications. We also f...

2006-01-01

344

Two-step template-free route for synthesis of TiO2 hollow spheres  

British Library Electronic Table of Contents (United Kingdom)

The TiO2 hollow microspheres were prepared by microwave-assisted solvothermal treatment without template. The morphology and the phase of TiO2 hollow microspheres were characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), high resolution transmission electron microscopy (HR-TEM), and BET surface areas. The results show that the particles have hollow structures and the shell was covered by nanocrystals and have higher specific surface area. The possible formation mechanism of hollow TiO2 spherical structures has simply been proposed. The activity was evaluated by the photocatalytic degradation of methyl orange (MO). The results show that the particles having specific surface area show higher photocatalytic activity. It can be attribute to the doped ...

2011-01-01

345

Tumour affinity of [sup 203]Pb-chloride: comparison with [sup 67]Ga-citrate and [sup 201]Tl-chloride  

Energy Technology Data Exchange (ETDEWEB)

[sup 203]Pb-chloride is a promising imaging agent for tumour scanning because of the large retention value for tumour tissue and the small value for normal organs, but the large value for the kidneys and bone is a shortcoming. The retention value of [sup 203]Pb in tumour tissue is larger than that of [sup 201]Tl and smaller than that of [sup 67]Ga. The tumour/inflammatory lesion retention ratio for [sup 203]Pb is very large in comparison with those for [sup 67]Ga and [sup 201]Tl. [sup 203]Pb accumulates to a large extent in viable tumour tissue, and less in necrotic tumour tissue and in inflammatory lesion. (author).

1994-01-01

346

Transuranic separation using organophophorus extractants adsorbed onto superparamagnetic carriers.  

Energy Technology Data Exchange (ETDEWEB)

Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the chemistry and ...

1998-10-07

347

Thermogravimetric and wide angle X-ray diffraction analysis of thermoplastic elastomers from nylon copolymer and EPDM rubber  

British Library Electronic Table of Contents (United Kingdom)

Nylon copolymer (PA6, 66) and ethylene propylene diene (EPDM) blends with and without compatibilizer were prepared by melt mixing using Brabender Plasticorder. The thermal stability of nylon copolymer (PA6, 66)/ethylene propylene diene rubber (EPDM) blends was studied using thermogravimetric analysis (TGA). The morphology of the blends was investigated using scanning electron microscopy (SEM). In this work, the effects of blend ratio and compatibilisation on thermal stability and crystallinity were investigated. The incorporation of EPDM rubber was found to improve the thermal stability of nylon copolymer. The kinetic parameters of the degradation process were also studied. A good correlation was observed between the thermal properties and phase morphology of the blends. By applying Coats ...

2008-01-01

348

Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium  

International Nuclear Information System (INIS)

This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K_2YF_5_:Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with "1"3"7Cs gamma rays as well as with "9"0Sr/"9"0Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)

2011-02-01

349

The formation and removal characteristics of aerosols in ammonia-based wet flue gas desulfurization  

British Library Electronic Table of Contents (United Kingdom)

The characteristics of aerosol generation were studied experimentally in an ammonia-based wet flue gas desulfurization process. Particle size distributions and concentrations, morphologies and compositions before and after desulfurization were measured using an electrical low pressure impactor and scanning electron microscopy, respectively. The results show that aerosols can be generated between ammonia and sulfur dioxide resulting in gas-phase reaction and the aerosol concentration at the outlet of scrubber is significantly higher than at the inlet. Before desulfurization the particles are primarily silica-alumina minerals including O, Al, Si and C, while after ammonia-based desulfurization aerosol particles have smooth surfaces with regular structures, such as cubic and prismatic crystal...

2011-01-01

350

The effects of physical activity, education, and body mass index on the aging brain  

British Library Electronic Table of Contents (United Kingdom)

Abstract Normal human aging is accompanied by progressive brain tissue loss and cognitive decline; however, several factors are thought to influence brain aging. We applied tensor-based morphometry to high-resolution brain MRI scans to determine whether educational level or physical activity was associated with brain tissue volumes in the elderly, particularly in regions susceptible to age-related atrophy. We mapped the 3D profile of brain volume differences in 226 healthy elderly subjects (130F/96M; 77.9 3.6 SD years) from the Cardiovascular Health Study-Cognition Study. Statistical maps revealed the 3D profile of brain regions whose volumes were associated with educational level and physical activity (based on leisure-time energy expenditure). After controlling for age, sex, and physical...

2011-01-01

351

The effect of SEM preparation on pit membrane remnants in vessel element end-walls of primitive angiosperms  

British Library Electronic Table of Contents (United Kingdom)

Scanning electron microscope (SEM) is necessary to demonstrate presence or absence of pit membranes in possible perforations or the type of pit membrane remnants in perforations in vessel element end-walls of angiosperms, but it was unconfirmed and questionable whether pit membrane absence in pits was affected by the processing and handling before SEM observations. To solve this question, the secondary xylem of four woody species from primitive angiosperms, Illicium henryi Diels. (Illiciaceae), Schisandra rubriflora (Franch.) Rehd. et Wils. (Schisandraceae), Tetracentron sinensis Oliv. and Trochodendron aralioides Sieb. & Zucc. (Trochodendraceae) was chosen and the following techniques were used: (1) fresh materials were examined in low-vacuum with ESEM. (2) Air-dried materials were examin...

2011-01-01

352

The carbon fiber surface treatment and addition of PA6 on tensile properties of ABS composites  

British Library Electronic Table of Contents (United Kingdom)

In this study acrylonitrile-butadiene-styrene (ABS) terpolymer was reinforced with HNO3-treated short carbon fibers (HCFs). The effects of HCF concentration on the tensile properties of the composites were examined. Increasing the HCF concentration in the ABS matrix from 10 wt% to 30 wt% resulted in improved tensile strength and tensile modulus. To obtain a strong interaction at the interface, polyamide-6 (PA6) at varying concentrations was introduced into the ABS/10 wt% HCF composite. The incorporation and increasing amount of PA6 in the composites increased tensile properties of the ABS/PA6/HCF systems due to the improved adhesion at the interface, which was confirmed by the ratio of tensile strength as an adhesion parameter. These results were also supported by scanning electron microgr...

2011-01-01

353

Synthesis of reversible fluorescent organogel containing 2-(2prime-hydroxyphenyl)benzoxazole: fluorescence enhancement upon gelation and detecting property for nerve gas simulant  

British Library Electronic Table of Contents (United Kingdom)

A new low molecular mass organogelator 1 containing 2-(2prime-hydroxyphenyl)benzoxazole (HPB) group with long alkyl chain was synthesized by the reaction with 5-amino-2-(2prime-hydroxy-4prime-methylphenyl)benzoxazole and dodecyl isocyanate in THF at room temperature. The reversible gelation ability of 1 was investigated using a heating-cooling method in various organic solvents. The stable organogel was formed from carbon tetrachloride or from cyclohexane at the concentration as low as 0.9%. The self-assembled supramolecular gel structure formed by non-covalent bonding was confirmed with field emission-scanning electron microscope (FE-SEM) exhibiting fibril- or ribbon-shaped structure depending on the solvent used. Regarding the aggregation-induced emission enhancement (AIEE) phenomenon, t...

2010-01-01

354

Synthesis and enhanced light absorption of alumina matrix nanocomposites containing multilayer oxide nanorods and silver nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

In this paper, multilayer oxide nanorods were deposited in the nanopores of anodic aluminum oxide (AAO) via solution infiltration followed by heat treatment. The nanorods have a core-shell structure. First, the shell (nanotube) with the thickness of about 40nm was made of TiO"2 through the hydrolysis of (NH"4)"2TiF"6. Second, silver nanoparticles with the diameter of about 3nm were added into the TiO"2 layer through thermal decomposition of AgNO"3 at elevated temperatures. Then, cylindrical cores (nanorods) of CoO and ZnO with 200nm diameter were prepared, respectively. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to characterize the structure and composition of the nanorods. UV-vis light absorption measurements in the wavelength range from 350 to...

2011-01-01

355

Synthesis and characterization of undoped and TM (Co, Mn) doped ZnO nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

Antibacterial activity of Transition metals (Mn, Co) doped ZnO nanopowders prepared by a DC thermal plasma method against Escherichia coli and Staphylococcus aureus are investigated. The phase and morphology studies have been carried out by X-ray diffraction, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) respectively. All the samples of the present investigation are found to have hexagonal wurtzite structure and crystallite sizes are found to vary from 25nm to 30nm. Our bacteriological study showed the enhanced antibacterial activity of transition metals doped ZnO nanoparticles than undoped ZnO indicating the great potential of ZnO nanoparticles in relevant clinical and biomedical applications.

2011-01-01

356

Synthesis and characterization of myristic acid capped silver nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

Reduction of silver myristate (AgMy) under mild thermal reaction conditions in a dipolar aprotic solvent i.e. N, N-dimethylformamide (DMF) has been carried out. UV-visible absorption measurements of dried and re-dispersible brown flocculants showed broad features of surface plasmon resonance (SPR) due to silver nanoparticles. The freshly isolated particles showed absorption bands at 414 and 485 nm, respectively, due to inter-particle coupling or clustering of silver ions and silver atoms. X-ray diffraction (XRD) pattern of fcc zero-valent silver resulted in crystallite size of about 10 nm. Scanning electron microscopy (SEM) revealed formation of rod shaped silver with increasing reaction temperature. Thermal analysis (TGA) showed about 10% weight loss due to organic capping.

2008-08-15

357

Synthesis and characterization of Fe3O4Gg nanocomposites and their antibacterial performance  

British Library Electronic Table of Contents (United Kingdom)

We synthesized Fe3O4Gg nanocomposites through a combination of solvothermal, hydrothermal, and chemical redox reactions. Characterization of the resulting samples by X-ray diffraction, Fourier-transform infrared spectroscopy, field-emission scanning and transmission electron microscopy, and magnetic measurement is reported. Compared to Fe3O4g nanocomposites, the Fe3O4Gg nanocomposites showed enhanced antibacterial activity. The Fe3O4Gg nanocomposites were able to almost entirely prevent growth of Escherichia coli when the concentration of Ag nanoparticles was 10mg/mL. Antibacterial activity of the Fe3O4Gg nanocomposites was maintained for more than 40h at 37^oC. The intermediate carbon layer not only protects magnetic core, but also improves the dispersion and antibacterial activity of the...

2011-01-01

358

Study on the solid state reaction between bilayered Pd/Au films and silicon substrates  

British Library Electronic Table of Contents (United Kingdom)

Bilayers of pure palladium and gold films were evaporated alternatively on (100) and (111) monocrystalline silicon substrates. After annealing, in a vacuum furnace from 100 to 650degreeC during 30min, the growth sequence of the Pd2Si and PdSi phases that evolved as the result of the diffusion reaction was examined by means of Rutherford backscattering spectrometry (RBS), X-ray diffraction (XRD), whereas the surface morphology was investigated by scanning electron microscopy (SEM) technique. The effect of the intermediate gold layer is investigated in order to test its effectiveness as barrier for Cu and Si atoms interdiffusion and its influence on the morphology of the formed palladium silicides. The effect of substrate orientation on the palladium silicides growth and formation was also e...

2006-01-01

359

Study on the interface of PVDF coatings and HF-treated AZ31 magnesium alloy: Determination of interfacial interactions and reactions with self-healing properties  

International Nuclear Information System (INIS)

Research highlights: ? Reports a high protection system for the alloy in corrosive environment. ? Describes an interfacial process with self-healing properties. ? Reports the influence of substrate pre-treatment in the coating performance. - Abstract: In this paper the interface of poly(vinylidene fluoride) coatings prepared by the dip coating method and HF-treated AZ31 magnesium alloy was evaluated. The best performance of this system in corrosion tests compared to ground, as-received and acetic acid cleaned substrates is related to an acid-base interaction at the interface and to interfacial reactions which resulted in a self-healing process. The protectiveness of the samples was investigated using impedance and immersion tests while the coating morphology and interface stability were investigated by scanning electron microscopy, X-ray photoelectron spectroscopy and adhesion tests.

2011-02-01

360

Study on fracture behaviour of Al?15%Mg2Si metal matrix composite with and without beryllium additions  

British Library Electronic Table of Contents (United Kingdom)

In this study, the influence of Beryllium (Be) content on the fracture behaviour of Al?15%Mg2Si composite was investigated. The results showed an increase in mechanical properties with increasing of Be content. The stress?strain curves of samples showed a same category of serrations reflecting non-uniform deformation. Scanning electron microscopy was employed to examine the crack nucleation and fracture model. The results indicate that Al?15%Mg2Si composite shows different behaviours of crack initiation and fracture for samples with and without Be. Differences observed in the fracture behaviour were attributed to microstructural changes as well as morphological aspects of primary Mg2Si particles.

2011-01-01

361

Study of the application of BATAN's equipment for nuclear forensic activities  

International Nuclear Information System (INIS)

Nuclear forensic activities, such as in illicit trafficking, can solve a problem who did it and can gain the basis for a response. Other than that, the forensics can be also applied to solve on what are materials, who is responsible, is there more, where was material diverted and what route did the material taken. BATAN, in fact , owns a lot of equipment which can be supported for nuclear forensics activities, such as, Transmission Electron Microscope (TEM), Scanning Electron Microscope (SEM) as well as X-Ray Diffraction (XRD). For the first step, BATAN has to be an active, participate member of The International Technical Working Group on Nuclear Smuggling (ITWG). BATAN can then collaborate not only with Indonesia Arm Forces and Police, but also with other foreign institutions to develop this activity with mutual advantages agreement.

2005-10-01

362

Study of surface segregation of Si on palladium silicide using Auger electron spectroscopy  

International Nuclear Information System (INIS)

The transformation of Pd/Si to Pd_2Si/Si is studied using Auger electron spectroscopy over a wide temperature range of 370-1020 K. The Pd film gets totally converted to Pd_2Si upon annealing at 520 K, and beyond 570 K, Si starts segregating on the surface of silicide. It is found that the presence of surface oxygen influences the segregation of Si. The time evolution study of Si segregation reveals that segregation kinetics is very fast and the segregated Si concentration increases as the temperature is increased. Scanning electron microscopy measurements show that Pd_2Si is formed in the form of islands, which grow as the annealing temperature is increased.

2004-11-21

363

Study of copper foam-supported Sn thin film as a high-capacity anode for lithium-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

Three-dimensional porous Sn thin film electrodes were prepared by electroless deposition on copper foam, then its morphology and electrochemical property were studied by means of scanning electron microscope (SEM), X-ray diffraction (XRD), electrochemical cycling test and cyclic voltammetry (CV). The porous framework and micro-holes have shown a great structure advantage in restricting severe volume changes when the Sn thin film was employed as anode for lithium-ion battery. The film electrode of sample C with an initial capacity of 676 mAh g{sup -1} showed good cycle performance displayed by retaining a capacity of 313 mAh g{sup -1} after 100 cycles.

2009-10-01

364

Studies on Cercariae from Kuwait Bay. X. Description and surface topography of Cercaria kuwaitae X sp. n. (Digenea: Renicolidae).  

Science.gov (United States)

A new renicolid cercaria, Cercaria kuwaitae X sp. n., from the prosobranch gastropod Cerithium scabridum from Kuwait Bay is described. The new cercaria is nonstyleted gymnocephalous with voluminous Y-shaped excretory vesicle, flame cell formula 2[(3 + 3 + 3) + (3 + 3 + 3)] = 36, and without caudal fins. Surface topography of the new cercaria is studied by scanning electron microscopy. Domed papillae are abundant on the anterior and lateral aspects of the body, ciliated papillae are sparse dorsally. The ventral sucker bears nine domed papillae. Domed papillae form two circles around the oral sucker with three circles of spines in between. This is the first renicolid cercaria to be recorded in a gastropod from the Arabian Gulf region. PMID:9789783

1997-12-01

365

Stent placement under real-time MR control: first experience in an animal model; Stentplazierung unter Echtzeit-MR-Kontrolle: erste tierexperimentalle Erfahrungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were identical to those ...

1998-12-01

366

Status of combined point source search with neutrino telescopes IceCube and AMANDA  

Energy Technology Data Exchange (ETDEWEB)

In this talk, we summarize recent results obtained from the combined neutrino telescopes IceCube and AMANDA. The combined approach, including data taken from both detectors simultaneously, is compared to other analyses that are using IceCube only data. The main benefit of the combined detector is its improved performance at low energies, meaning energies below 1 TeV (close to the energy threshold of the detector). The discussion is focused on the search for extra-terrestrial neutrinos from candidate sources in our Galaxy. Using appropriate cuts, the sensitivity can be optimized for soft spectra neutrino sources. With the resulting data sample, several studies are performed: an unbinned Galactic Plane Scan and a Cygnus region analysis: the Multi Point Source analysis. The current status of these analyses is presented.

2010-07-01

367

Soluble starch?based biodegradable and microporous microspheres as potential adsorbent for stabilization and controlled release of coix seed oil  

British Library Electronic Table of Contents (United Kingdom)

Soluble starch?based biodegradable and microporous microspheres (SDM-Ms) were prepared by emulsion chemical cross-linking technique using trisodium trimetaphosphate (TSTP) as the cross-linker. The resultant amorphous SDM-Ms were excellently identified by scanning electron microscopy (SEM), X-ray diffraction (XRD), and Fourier transform infrared spectroscopy (FT-IR). The internal rupture and surface-controlled erosion were the predominant degradation mechanisms for SDM-Ms. The obtained SDM-Ms were applied to adsorb coix seed oil (CSO) by immersing method. The adsorption capacity of CSO within SDM-Ms was determined, namely 0.5238?g/g, and the thermal stability was shown higher than that of the free CSO. A burst release appeared in the second hour, followed by controlled release. Diffusion, d...

2011-01-01

368

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

Energy Technology Data Exchange (ETDEWEB)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10{sup -4} M to 10{sup -1} M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhibitor.

2008-06-15

369

Sodium gluconate as corrosion and scale inhibitor of ordinary steel in simulated cooling water  

British Library Electronic Table of Contents (United Kingdom)

The effect of sodium gluconate anion (SG) on the corrosion and scale inhibition of ordinary steel in simulated cooling water has been studied using weight loss, polarisation curves, electrochemical impedance spectroscopy (EIS) and scanning electron microscopy (SEM) techniques. SG was studied in concentration from 10-4M to 10-1M. Results obtained reveal that SG perform excellently as corrosion and scaling inhibitor for ordinary steel in simulated cooling water. An increase of SG concentration leads to the increase of the corrosion potential towards the positive direction. The inhibition efficiency was a low temperature dependence. The inhibitor mechanism was treated as an adsorption process according to Langmuir adsorption isotherm. The SEM/EDAX data show that was a corrosion and scale inhi...

2008-01-01

370

Size-controlled Ag nanoparticle modified WO3 composite films for adjustment of electrochromic properties  

British Library Electronic Table of Contents (United Kingdom)

Size-controllable Ag nanoparticle ultrathin films, which were fabricated by vacuum deposition method from high purity Ag wire onto cleaned indium tin oxide conducting glass, have different color fabricated by variation of preparation conditions. The UV/Vis spectra showed that optical absorption peak of these Ag nanoparticle films can be tuned in a range from 457nm to >650nm. Scanning electron microscopy images showed that with increasing film thickness Ag particle size was larger. Ag/WO3 composite films were prepared by cathodic electrodeposition of WO3 onto the surface of Ag nanoparticle films. Spectroelectrochemistry and electrochromic properties of the resulting composite films were characterized. It was found that the electrochemical and electrochromatic properties of the composite fil...

2010-01-01

371

Single-step mineralization of woodpile chitosan scaffolds with improved cell compatibility  

British Library Electronic Table of Contents (United Kingdom)

Abstract A facile and efficient single-step mineralization approach was exploited for achieving nanoscopic hydroxyapatite (HAP) crystal layer in chitosan porous matrix, wherein a mixed water-ethanol solvent was used to control the growth of minerals. The crystallographic structure, morphology, and mechanical properties of the scaffold were analyzed with XRD, FTIR, environmental scanning electric microscopy (ESEM), TEM, and compression tests. The behaviors and responses of MC3T3-E1 pre-osteoblast cells on the scaffolds were studied as well. The results showed that the scaffolds kept woodpile structure with predefined and controlled hierarchical structure after mineralization. The inorganic phase in the mineralized chitosan scaffolds was determined as pure rod-like HAP, which settled densely...

2011-01-01

372

Simple chemical method for nanoporous network of In2S3 platelets for buffer layer in CIS solar cells  

British Library Electronic Table of Contents (United Kingdom)

Indium sulfide thin films consisting of porous network of nanoplatelets, have been deposited using chemical bath deposition (CBD) method onto the tin-doped indium oxide (ITO) coated glass substrate. Aqueous solutions of indium sulfate and thioacetamide have been used as indium and sulfur precursors. As a complexing agent, acetic acid was used. The chemically deposited indium sulfide thin films were examined for their structural, surface morphological and optical characterizations. The X-ray diffraction analysis revealed the formation of the cubic b-In2S3 onto the substrate. From scanning electron micrograph, it is observed that the surface of substrate is covered by nanoporous platelets type morphology. The optical studies showed a direct band gap of 2.84eV for indium sulfide platelets. Ph...

2008-01-01

373

Silica-reinforced natural rubber prepared by the sol-gel process of ethoxysilanes in rubber latex  

British Library Electronic Table of Contents (United Kingdom)

Silica-reinforced natural rubber (NR) composite was prepared by using tetraethoxysilane (TEOS) as a precursor to generate silica particles inside the rubber. The silica was generated in situ by the sol-gel process of TEOS that was mixed directly into commercial-graded NR latex having 60% dry rubber content and 0.7% ammonia. The conversions of TEOS to silica inside the rubber were ranging from 90 to 97%. The silica particles dispersed evenly without extensive aggregation with sizes between 100 and 500 nm, as determined by scanning electron microscopy (SEM). An experimental design methodology, namely "two-level factorial design," was used to evaluate the influence of the amounts of TEOS, ammonia, and gelation time on the tensile modulus, tensile strength, and tear strength of the vulcanizate...

2008-01-01

374

Severe paraquat poisoning: clinical and radiological findings in a survivor  

International Nuclear Information System (INIS)

Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a discussion of the therapeutic algorithm for ...

375

Severe paraquat poisoning: clinical and radiological findings in a survivor  

Energy Technology Data Exchange (ETDEWEB)

Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a discussion of the therapeutic algorithm for ...

2010-07-01

376

Search for tachyons preceding cosmic ray extensive air showers of energy >= 10"1"4 eV  

International Nuclear Information System (INIS)

A search for tachyons preceding extensive air showers has been conducted using an air shower array operated in conjunction with a large aperture, five element cosmic ray telescope. More than 200 000 air showers of primary energy >10"1"4 eV were observed over a period of 223 days and a 290 #mu#s period before each of these showers was scanned for a related particle signal from the telescope. In this way a particle arrival time spectrum containing 1519 tachyon candidates was observed. No convincing evidence was found for any subgroup of these events that might be attributable to tachyons. (author).

377

SSRM characterisation of FIB induced damage in silicon  

International Nuclear Information System (INIS)

Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.

2008-03-01

378

Root Hairs Play a Key Role in the Endophytic Colonization of Olive Roots by Pseudomonas spp. with Biocontrol Activity  

British Library Electronic Table of Contents (United Kingdom)

The use of indigenous bacterial root endophytes with biocontrol activity against soil-borne phytopathogens is an environmentally-friendly and ecologically-efficient action within an integrated disease management framework. The earliest steps of olive root colonization by Pseudomonas fluorescens PICF7 and Pseudomonas putida PICP2, effective biocontrol agents (BCAs) against Verticillium wilt of olive (Olea europaea L.) caused by the fungus Verticillium dahliae Kleb., are here described. A gnotobiotic study system using in vitro propagated olive plants, differential fluorescent-protein tagging of bacteria, and confocal laser scanning microscopy analysis have been successfully used to examine olive roots?Pseudomonas spp. interactions at the single-cell level. In vivo simultaneous visualization...

2011-01-01

379

Removal of natural humic acids by decolorizing actinomycetes isolated from different soils (Algeria) for application in water purification  

British Library Electronic Table of Contents (United Kingdom)

Humic acids are considered problematically in drinking water because it can react readily with chlorine to form carcinogen compounds and its biological removal is much recommended. The scanning electron microscopy morphologies and optical parameters observed for natural humic acids (NHAs) extracted from different soils at Mitidja plain (Algeria) made them different from the commercial ones. Three of the most active strains of 19 actinomycetes were isolated and selected from surface soils at this plain. These strains were identified based on cultural characteristics and chemotaxonomic analysis and classified in the genus Streptomyces. Growth of these strains was assured on a poor liquid medium containing NHAs as carbon and nitrogen sources and degradation occur only in the presence of gluco...

2010-01-01

380

Real time automatic discriminating of ultrasonic flaws  

International Nuclear Information System (INIS)

This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)

2009-07-20

381

Range-resolved gas concentration measurements using tunable semiconductor lasers  

British Library Electronic Table of Contents (United Kingdom)

A method for range-resolved gas sensing using path-integrated optical systems is presented. The method involves dividing an absorption path into several measurement segments and extracting the gas concentration in each segment from two path-integrated measurements. We implemented the method with tunable lasers (a 1389-nm VCSEL and a 10.9-?m pulsed quantum cascade laser) and a group of retro reflectors (RRs) distributed along absorption paths. Using a rotating mirror with the VCSEL configuration, we could scan a group of seven tape RRs spaced by 10?cm in ??9?ms to extract an H2O concentration profile. Reduced H2O concentrations were recorded in the segments purged with dry air. Hollow corner cube RRs were used in the quantum cascade laser configuration at distances up to 1.1?km from the las...

2008-01-01

382

Radiation risk in computerized tomography (CT)  

Energy Technology Data Exchange (ETDEWEB)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the ...

1984-01-01

383

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the ...

1984-01-01

384

Radiation risk in computerized tomography (CT)  

International Nuclear Information System (INIS)

The two main aspects of the concept proposed by the ICRP in recommendation 26 for the radiation risk, the differentiation of stochastic and non stochastic damages and the qualification of the stochastic risk, are discussed in its consequences for radiation protection in X-ray diagnostics. Quantitative results from the literature serve to demonstrate the risk factors for the various organs and their sum concerning the position of the layer. As special points of somatic risk appeared the mamma and the pelvic region. The particular risk of CT examination is determined by number and position of the layers and the scan parameters of the system. For typical CT examination the resulting risk factors are estimated in comparison with conventional X-ray diagnostics. The somatic risk of CT examination is relatively high and comparable to conventional examination with the highest risk, while the genetic risk - as in conventional diagnostics - depends on the distance of the ...

385

Progressive neurostructural changes in adolescent and adult patients with bipolar disorder  

British Library Electronic Table of Contents (United Kingdom)

Lisy ME, Jarvis KB, DelBello MP, Mills NP, Weber WA, Fleck D, Strakowski SM, Adler CM. Progressive neurostructural changes in adolescent and adult patients with bipolar disorder.-Bipolar Disord 2011: 13: 396-405. 2011 The Authors.-Journal compilation 2011 John Wiley & Sons A/S. Objectives:- Several lines of evidence suggest that bipolar disorder is associated with progressive changes in gray matter volume (GMV), particularly in brain structures involved in emotional regulation and expression. The majority of these studies however, have been cross-sectional in nature. In this study we compared baseline and follow-up scans in groups of bipolar disorder and healthy subjects. We hypothesized bipolar disorder subjects would demonstrate significant GMV changes over time. Methods:- A total of 58 ...

2011-01-01

386

Preparation of nanocomposite dispersions based on cellulose whiskers and acrylic copolymer by miniemulsion polymerization: Effect of the silane content  

British Library Electronic Table of Contents (United Kingdom)

Abstract A one step method was used to prepare stable aqueous nanocomposite dispersions based on cellulose whiskers extracted from the rachis of the date palm tree and a poly(styrene co 2 ethyl hexylacrylate) copolymer via miniemulsion polymerization. A reactive silane, i.e., methacryloxypropyl triethoxysilane was added to stabilize the dispersion and favor the anchoring of the whiskers on polymer particles. Dynamic light scattering was used to study the effect of the silane and whiskers contents on the average particle size of the polymer. Nanocomposites materials were prepared from these dispersions using a casting/evaporation method. The effect of the silane and whiskers contents on the thermal and mechanical properties were studied using differential scanning calorimetry and dynamic me...

2011-01-01

387

Preparation of AgCl Nanoparticles@Ancient Textile with Antibacterial Activity under Ultrasound Irradiation  

British Library Electronic Table of Contents (United Kingdom)

The growth of silver chloride nanoparticles on ancient textile was achieved by sequential dipping steps in alternating bath of potassium chloride and silver nitrate under ultrasound irradiation. The effect of ultrasound irradiation and sequential dipping steps in growth of the AgCl nanoparticles has been studied. These systems depicted a decrease in the particles size accompanying a decrease in the sequential dipping steps. The samples were characterized with powder X-ray diffraction (XRD) and scanning electron microscopy. XRD analyses indicated that the prepared AgCl nanoparticles on fiber were crystalline. The textile samples containing AgCl nanoparticles were tested for their antibacterial efficacy against Escherichia coli and were found to possess significant antibacterial activity.

2011-01-01

388

Preparation and characterization of nano hydroxyapatite/polymeric composites materials. Part I  

British Library Electronic Table of Contents (United Kingdom)

The present study is focused on preparation of nano composite materials and the effect of citric acid on their different properties. The formation of nano HA and its interaction with chitosan (C), gelatin (G) polymers and citric acid (CA) materials were studied. The Fourier Transformed Infrared Spectroscopy (FT-IR), X-ray diffraction (XRD), thermo-gravimetric analysis (TGA), transmission electron microscope (TEM), and scanning electron microscope (SEM) were used to characterize these composite materials. The compressive strength (CS) was also measured to know the reinforcement of the prepared composites. The results show that carboxylic and amino groups play crucial role for HA formation on chitosan-gelatin polymeric matrix in the presence of citric acid (CA). The formation of nano HA part...

2011-01-01

389

Preparation and Characterization of a Novel Polyamide Charged Mosaic Membrane  

British Library Electronic Table of Contents (United Kingdom)

A novel composite charged mosaic membrane (CCMM) was prepared via interfacial polymerization (IP) of polyamine [poly(epichlorohydrin amine)] and trimesoyl chloride (TMC) on the polyethersulfone (PES) support. Fourier transform infrared spectroscopy (FT-IR), environmental scanning electron microscopy (ESEM), atomic force microscopy (AFM) and water contact angle analysis were applied to characterize the resulted CCMM. The FT-IR spectrum indicates that TMC reacts sufficiently with polyamine. ESEM and AFM pictures show that the IP process produces a dense selective layer on the support membrane. The water contact angle of the CCMM is smaller than that of the substrate membrane because of the cross-linked hydrophilic polyamine network. Several factors affecting the IP reaction and the performan...

2010-01-01

390

Positron annihilation study on thin-film composite pervaporation membranes: Correlation between polyamide fine structure and different interfacial polymerization conditions  

British Library Electronic Table of Contents (United Kingdom)

To investigate the variation in the fine structure of polyamide thin-film composite (TFC) membranes prepared via two different interfacial polymerization conditions (IP-I and IP-II), experiments on Scanning Electron Microscopy (SEM), Atomic Force Microscopy (AFM), water contact angle, and positron annihilation spectroscopy (PAS) coupled to a slow positron beam were conducted. Polyamide TFC membranes were prepared via the interfacial polymerization reaction between triethylenetetramine (TETA) and trimesoyl chloride (TMC) on the surface of a modified polyacrylonitrile (mPAN) membrane. Compared with the polyamide TFC membrane prepared via IP-I, the polyamide layer prepared via IP-II showed a shorter S plateau length (thinner thickness), a higher o-Ps intensity I3 value (higher free-volume con...

2010-01-01

391

Photodynamic efficacy of hypericin targeted by two delivery techniques to hepatocellular carcinoma cells  

British Library Electronic Table of Contents (United Kingdom)

The photocytotoxic effect of hypericin (Hyp) targeted by two different delivery techniques, namely, liposomes and anti-hepatocyte specific antigen (anti-HSA) was investigated. Optical absorption and steady-state fluorescence were used to analyze the conjugation of Hyp with anti-HSA model and to evaluate the encapsulation capacity and drug release in a liposome model. Particle size and thermal analysis of the prepared liposomes were performed using laser-light scattering and differential scanning calorimetry (DSC), respectively. Viability study of HepG2 cells exposed to Hyp in the two delivery systems, in the dark and following visible light irradiation, was performed in comparison to free Hyp. The intracellular uptake and localization of Hyp in HepG2 cells were analyzed by means of spectro...

2010-01-01

392

Pd adsorption on Si(1 1 3) surface: STM and XPS study  

Energy Technology Data Exchange (ETDEWEB)

Pd-induced surface structures on Si(1 1 3) have been studied by scanning tunneling microscopy (STM) and X-ray photoelectron spectroscopy (XPS). In the initial process of the Pd adsorption below 0.10 ML, Pd silicide (Pd{sub 2}Si) clusters are observed to form randomly on the surface. By increasing the Pd coverage to 0.10 ML, the clusters cover the entire surface, and an amorphous layer is formed. After annealing the Si(1 1 3)-Pd surface at 600 deg. C, various types of islands and chain protrusions appears. The agglomeration, coalescence and crystallization of these islands are observed by using high temperature (HT-) STM. It is also found by XPS that the islands correspond to Pd{sub 2}Si structure. On the basis of these results, evolution of Pd-induced structures at high temperatures is in detail discussed.

2008-09-30

393

Oxidation of polycaprolactone to induce compatibility with other degradable polyesters  

British Library Electronic Table of Contents (United Kingdom)

Chemical modification of poly(?-caprolactone) PCL by oxidation with potassium permanganate in solution was investigated. According to the data obtained from Fourier transform infrared spectroscopy (FT-IR) and nuclear magnetic resonance 1H NMR, after the oxidation reactions the PCL chains exhibited new functional groups (vinyl and hydroxyl) and possible intermolecular recombination, producing an oxidized-polycaprolactone (PCL-OX). Solution viscometry indicated that degradation also occurred during the oxidation reactions (30% drop in viscosity average molecular weight was detected). Differential scanning calorimetry (DSC) also indicated that PCL was chemically modified and degraded. The successive self-nucleation/annealing (SSA) treatment confirmed that a reduction (or interruption) in line...

2007-01-01

394

Optimization of band gap of photonic crystals fabricated by holographic lithography  

Science.gov (United States)

Generally the photonic band gap (PBG) is a multi-variable function of several parameters related to the shape and size of the dielectric columns of photonic crystals (PhCs), and a time-consuming step-by-step scanning process for each parameter has to be used to find their best combination yielding maximum PBG. In this letter, the widely used Nelder-Mead simplex algorithm is introduced to optimize these parameters simultaneously to find a larger PBG for a new kind of two-dimensional (2D) hexagonal GaAs-Air PhC. This structure can be conveniently produced by the single-exposure holographic lithography, and the specific holographic design is also systematically investigated. This study reveals that the band gaps of PhCs made by holographic lithography may be widened by introducing irregularity of the columns and lowering the symmetry of the structure.

2008-01-01

395

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared with direct beam profile measurements.

2009-02-11

396

Observation of dust stream formation produced by low current, high voltage cathode spots  

International Nuclear Information System (INIS)

Macroparticle acceleration driven by low current, high voltage cathode spots has been investigated for potential applications ranging from micrometeoroid simulation to nanoparticle deposition/implantation. Acceleration by this process was observed to occur when nanometer and micrometer-sized particles were exposed to a high voltage pulse in the presence of a plasma discharge. The applied negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provide the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. Cathode spot behavior was also documented. The particle impact craters observed at the surface of downstream witness badges were documented using scanning electron microscopy and light microscopy. The observed impacts suggest the presence of energetic macroparticles formed during this process.

2004-04-01

397

Observation of 77 K staircase I-V characteristics in 2DEG's irradiated by a focused ion beam  

International Nuclear Information System (INIS)

Staircase current-voltage (I-V) characteristics, observed at 77 K in narrow 2DEG channels irradiated by a single line scan of a focused ion beam (FIB), is reported in detail. These staircases are interpreted as evidence of single electron tunneling through a naturally occurring specific Coulomb island in the random potential fluctuations created by FIB damage. Clear comparison is made between the I-V's taken from wide channels and those from narrow channels. Based on orthodox calculations of the I-V characteristics, it is shown that highly asymmetric tunnel junctions are needed to explain our data. This is consistent with the random nature of the potential landscape in the FIB damaged region. (author).

398

Nondestructive techniques for the control of conditioned radioactive wastes  

International Nuclear Information System (INIS)

The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.

2005-09-01

399

New trends in phospholipid class composition of marine sponges  

British Library Electronic Table of Contents (United Kingdom)

The exceptional ability of marine sponges to adapt to often drastic changes of their environments could be due to special structural features in cell membranes, including firstly phospholipids (PL). Thus, PL class composition was investigated in marine sponges (22 species from 19 genera to 15 families) originating from various locations (East Atlantic, North Atlantic, South-West Pacific, Mediterranean Sea, Red Sea, Arabian?Persian Gulf). The quantitative determination of PL class composition was obtained by high-performance thin-layer chromatography (HPTLC) with scanning densitometry of the different spots. Previous reports have shown phosphatidylethanolamine (PE) as the major PL class in marine sponges, followed by phosphatidylcholine (PC), while other papers described PC as a minor class...

2008-01-01

400

New starches: Physicochemical properties of sweetsop (Annona squamosa) and soursop (Anonna muricata) starches  

British Library Electronic Table of Contents (United Kingdom)

Starch from the fruits of sweetsop (Anonna squamosa) and soursop (Anonna muricata) were isolated and purified and the fat, ash, phosphorus and protein contents measured. The amount of amylose present was determined spectrophotometrically and found to be very similar (19%) for both starches. Scanning electron microscopy showed very small indented and spherical granules from both with an average granule size of 4.84mm and 4.72mm, respectively. The physicochemical properties, namely the swelling power, solubility, pasting characteristics, paste clarity and freeze-thaw stability were studied to assess the functionality of the starch pastes as hydrocolloids. The sweetsop starch showed higher swelling power and solubility compared to soursop starch and had a lower gelatinization temperature indi...

2009-01-01

401

New implementation of a shear-force microscope suitable to study topographical features over wide areas  

International Nuclear Information System (INIS)

A new implementation of a shear-force microscope is described that uses a shear-force detection system to perform topographical imaging of large areas (#approx#1x1 mm"2). This implementation finds very interesting application in the study of archeological or artistic samples. Three dc motors are used to move a sample during a scan, allowing the probe tip to follow the surface and to face height differences of several tens of micrometers. This large-area topographical imaging mode exploits new subroutines that were added to the existing homemade software; these subroutines were created in Microsoft VISUAL BASIC 6.0 programming language. With this new feature our shear-force microscope can be used to study topographical details over large areas of archaeological samples in a nondestructive way. We show results detecting worn reliefs over a coin.

2006-09-01

402

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.

403

Morphology, structure, and conductivity of polypyrrole prepared in the presence of mixed surfactants in aqueous solutions  

British Library Electronic Table of Contents (United Kingdom)

Polypyrrole (PPy) was prepared from different mixed-surfactant solutions with ammonium persulfate as an oxidant. Three types of combinations were selected, including cationic/anionic, cationic/nonionic, and anionic/nonionic mixed-surfactant solutions. The surfactants used in the experiments included cetyltrimethylammonium bromide (cationic surfactant), sodium dodecyl sulfate (anionic surfactant), sodium dodecyl sulfonic acid salt (anionic surfactant), poly(vinyl pyrrolidone) (nonionic surfactant), and poly(ethylene glycol) (nonionic surfactant). The morphology, structure, and conductivity of the resulting PPy were investigated in detail with scanning electron microscopy, Fourier transform infrared spectra, and the typical four-probe method, respectively. The results showed that the interac...

2007-01-01

404

Morphology of the first instar of Calliphora vicina, Phormia regina and Lucilia illustris (Diptera, Calliphoridae)  

British Library Electronic Table of Contents (United Kingdom)

Abstract. Scanning electron microscopy documentation of first instar Calliphora vicina Robineau-Desvoidy, Phormia regina (Meigen) and Lucilia illustris (Meigen) (Diptera: Calliphoridae) is presented for the first time, and the following morphological structures are documented: pseudocephalon; antenna; maxillary palpus; facial mask; labial lobe; thoracic and abdominal spinulation; spiracular field; posterior spiracles, and anal pad. Light microscopy documentation and illustrations are provided for the cephaloskeleton in lateral and ventral views. New diagnostic features are revealed in the configuration of the facial mask, cephaloskeleton and posterior spiracles. The first instar morphology of C. vicina, Ph. regina and L. illustris is discussed in the light of existing knowledge about early...

2008-01-01

405

Morphology of modified starches prepared by different methods  

British Library Electronic Table of Contents (United Kingdom)

Morphologies of modified starches prepared using different methods were examined by scanning electron microscopy (SEM). These SEM micrographs provide the following results. To begin with, starch granules underwent a series of changes which resulted in the morphology of modified starch quite different from the native starch with different the methods during the process of modification. For example, hollows emerge on the granules of maltodextrin with low value of dextrose equivalent (DE) prepared by means of spray-drying, but they fell to pieces with the increasing value of DE. The granules of pregelatinized starches manufactured with extrusion technology also showed irregular stone shapes and holes within them while those produced by means of drum-drying presented irregular laminar structur...

2010-01-01

406

Morphology and properties of silane-modified montmorillonite clays and clay/PBT composites  

British Library Electronic Table of Contents (United Kingdom)

Commercially available organoclay (Closite 30B) was modified by using 3-aminopropyltriethoxysilane (APS) via a silylation reaction. Sodium clay (Closite Na) was treated by APS directly as a control. Such modified clays were further melt-compounded with polybutylene terephthalate (PBT). The morphology and properties of the modified organoclays were characterized with X-ray diffraction (XRD), transmission electrical microscopy (TEM), Infra-red spectroscopy, contact angle measurement, and thermogravimetric analysis (TGA). The effects of modified clays on the crystallization behavior of PBT were characterized by differential scanning calorimetry. The basal spacing of Closite Na was enlarged from 1.01 to 1.41 nm after APS treatment, indicating that the APS was intercalated into the clay interga...

2008-01-01

407

Monosodium titanate particle characterization  

Energy Technology Data Exchange (ETDEWEB)

A characterization study was performed on monosodium titanate (MST) particles to determine the effect of high shear forces expected from the In-Tank Precipitation (ITP) process pumps on the particle size distribution. The particles were characterized using particle size analysis and scanning electron microscopy (SEM). No significant changes in particle size distributions were observed between as-received MST and after 2--4 hours of shearing. Both as-received and sheared MST particles contained a large percentage of porosity with pore sizes on the order of 500 to 2,000 Angstroms. Because of the large percentage of porosity, the overall surface area of the MST is dominated by the internal surfaces. The uranium and plutonium species present in the waste solution will have access to both interior and exterior surfaces. Therefore, uranium and plutonium loading should not be a strong function of MST particle size.

1993-01-12

408

Modeling of sputtering and redeposition in focused-ion-beam trench milling  

Energy Technology Data Exchange (ETDEWEB)

Modeling is performed for focused-ion-beam (FIB) sputtering and redeposition on trench sidewalls in a steady state approximation. Calculations are carried out to demonstrate the sputtered surface profile under known parameters such as sputtering yield as a function of ion incident angle, the FIB current density profile, and the FIB scan speed. It is found that a steplike slope with a gradient angle of {theta}{sub 0} is formed at the FIB bombarding position. Furthermore, the redeposition flux on the sidewalls is calculated as a function of {theta}{sub 0} for the FIB trench milling assuming the cosine law for the angular distribution of the sputtered atom. The redeposition will be more accurately predictable and controllable when more information about these assumptions is obtained.

1991-11-01

409

Modeling of sputtering and redeposition in focused-ion-beam trench milling  

International Nuclear Information System (INIS)

Modeling is performed for focused-ion-beam (FIB) sputtering and redeposition on trench sidewalls in a steady state approximation. Calculations are carried out to demonstrate the sputtered surface profile under known parameters such as sputtering yield as a function of ion incident angle, the FIB current density profile, and the FIB scan speed. It is found that a steplike slope with a gradient angle of #theta#_0 is formed at the FIB bombarding position. Furthermore, the redeposition flux on the sidewalls is calculated as a function of #theta#_0 for the FIB trench milling assuming the cosine law for the angular distribution of the sputtered atom. The redeposition will be more accurately predictable and controllable when more information about these assumptions is obtained.

410

Microstructure and tool electrode erosion in EDMed of TiN/Si_3N_4 composites  

International Nuclear Information System (INIS)

Conductive TiN/Si_3N_4 ceramic composites were processed by electrical discharge machining (EDM) and their microstructure and conductivity were investigated. The whole process of tool electrode wear is evaluated by sinker-EDM. The machined surfaces of TiN/Si_3N_4 ceramic composites were examined by scanning electron microscopy (SEM) and profilometry to determine the surface finish. The electrode wear rate of brass is higher than copper electrode for all EDMed tests. The surface texture was found to have greater dependence on pulse energy. It was observed that the sinker-EDM at higher pulse energy caused severe microdamage in the surface. The surface roughness (Ra) values also increase with increasing pulse energy.

2003-12-20

411

Microstructural aspects of the corrosion of Alloy 800  

International Nuclear Information System (INIS)

Transmission electron microscopy studies on solution-annealed Alloy 800 revealed small (100-200 nm), spherical-shaped titanium carbide (face centered cubic structure) and large (200 nm-5 #mu#m), faceted titanium nitride (hexagonal structure) particles randomly distributed in the austenite matrix. The volume fraction of former particles was found to be greater than that of the latter. Corrosion studies of the alloy in acidic, chlorides and acidic chloride environments at room temperature indicated that the passivity of Alloy 800 was adversely affected by the addition Cl"- ions. X-ray photoelectron spectroscopy revealed that the surface film formed on the alloy at the onset of passivity consisted of Cr"3"+ (as Cr_2O_3), without any Fe"3"+/Fe"2"+ or Ni"2"+. Scanning electron microscopy studies indicated initiation of pitting at large, faceted particles, not at small, spherical-shaped ones.

2004-12-01

412

Microsporogenesis and pollen formation in cassava  

British Library Electronic Table of Contents (United Kingdom)

This article describes the complete microsporogenesis and pollen formation in cassava (Manihot esculenta Crantz) at the various developmental stages (pollen mother cell, meiosis, tetrads, early free spore, mid uninucleate, late uninucleate, binucleate and mature pollen grain). Light microscopy, transmission electron microscopy and confocal laser scanning microscopy were used for the study. Floral bud size and other inflorescence characteristics were correlated with specific stages of the microspore development. This association allows a rapid selection of floral buds with similar microspore developmental stages, useful when a large number of homogeneous cells are needed for analysis and for in vitro induction of androgenesis. This article also compares methods for digestion the exine wall ...

2011-01-01

413

Micromachining of CVD diamond films using a focused ion beam  

Energy Technology Data Exchange (ETDEWEB)

Grooving CVD diamond films using a focused ion beam (FIB) to quarry micro parts is described. The substrate-side surface of a polycrystalline diamond film which is prepared by means of microwave plasma CVD, is able to be grooved by a focused Ga ion beam scanned straight repeatedly. The groove has cross section whose shape is like an inverted Gaussian distribution curve. And the surface roughness of the films before grooved influences that of grooves. Under the same irradiation conditions, deeper, narrower, in short, high aspect ratio grooves are obtained on B-doped semiconducting microwave plasma CVD diamond films. Coating electrical conductive material is also effective method to obtain high aspect ratio grooves. It is supposed that these results are due to the degree of electrification on the surface and that FIB irradiation is a suitable method for micromachining semiconducting diamond films.

1995-12-31

414

Metallurgical Investigation of a Prematurely Failed Concentric Reducer Tube Used in a Hot-Rolling Mill  

British Library Electronic Table of Contents (United Kingdom)

A concentric reducer tube, which was a part of the top exit roughing hydraulic descaler in a hot strip mill failed prematurely under working pressure. A detailed metallurgical investigation comprising physical examination, optical microscopy, scanning electron microscopy, and electron probe microanalysis was carried out to find out the genesis of the failure. Physical examination revealed cracks located symmetrically around the circumference of the tube that ran along its full length, up to the weld beads at both ends. Optical microscopy of etched samples revealed a banded ferrite-pearlite structure and the existence of forging folds near the change-in-section(160? fillets). Cracks were found to initiate from these forging folds. No structural abnormalities were found in the weld beads and...

2007-01-01

415

Mechanical behavior of self-assembled carbon nanotube reinforced nylon 6,6 fibers  

British Library Electronic Table of Contents (United Kingdom)

The versatile electrospinning technique was used to successfully align and disperse multiwalled carbon nanotubes (MWCNT) in nylon 6,6 matrix to obtain composite fibers. The morphology of the composite fibers and the dispersion of the CNTs within the fibers were analyzed using scanning electron microscopy (SEM) and transmission electron microscopy (TEM), respectively. TEM analysis revealed that the CNTs were well-dispersed, separated and aligned along the fiber axis. The thermal and mechanical properties of the composite fibers were characterized as a function of weight fraction of the CNTs. Incorporation of the CNTs in the fibers resulted in an increase in glass-transition temperature (Tg) by 7degreeC, indicating that the addition of CNTs has restricted the mobility of the polymer chains a...

2010-01-01

416

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

Energy Technology Data Exchange (ETDEWEB)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

1988-07-01

417

Mapping of local cerebral blood flow with stable xenon-enhanced CT and the curve-fitting method of analysis  

International Nuclear Information System (INIS)

A noninvasive method is described for estimating local cerebral blood flow (LCBF) and local partition coefficients by means of computed tomographic scanning during inhalation of 30% stable xenon gas in oxygen. Time-dependent xenon concentrations in arterial blood and brain tissue during the wash-in and washout phases are used to calculate partition coefficients and LCBF values by means of a least-squares curve-fitting analysis. Control values for partition coefficient and LCBF obtained from control subjects with minor head trauma in the chronic stage were compatible with those in several past reports, and reproducibility was satisfactory. The theoretic grounds underlying this new method of curve-fitting analysis are discussed.

418

Low temperature deposition and characterization of TiO{sub 2} photocatalytic film through cold spray  

Energy Technology Data Exchange (ETDEWEB)

Cold spray was employed as a novel low temperature approach to deposit titanium dioxide (TiO{sub 2}) photocatalytic film. The film microstructure was characterized using X-ray diffraction and scanning electron microscopy. The photocatalytic performance was examined through acetaldehyde degradation under ultraviolet illumination. Results showed that TiO{sub 2} film was successfully deposited on substrate surface through cold spray. The film thickness reached up to 15 {mu}m. The film presented a rough surface and porous structure. Owing to the low temperature of spray powder, no phase and particle size changes occurred to TiO{sub 2} during deposition. It was found that the cold-sprayed TiO{sub 2} film was active for photodegradation of acetaldehyde.

2008-04-30

419

Layer-by-layer assembly of functional silica and Au nanoparticles for fabricating electrogenerated chemiluminescence sensor  

Energy Technology Data Exchange (ETDEWEB)

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy){sub 3}{sup 2+} and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy){sub 3}{sup 2+}-doped silica nanoparticles and Au nanoparticles. UV-vis absorption spectroscopy, scanning electron microscopy (SEM), cyclic voltammetry and ECL were used to characterize the uniform growth of the multilayer film. Since Ru(bpy){sub 3}{sup 2+} could still maintain its ECL property when doped into the silica nanoparticles, the as-prepared multilayer film could be used as an effective ECL sensor, and the sensor showed high sensitivity and good stability.

2008-09-20

420

Layer-by-layer assembly of functional silica and Au nanoparticles for fabricating electrogenerated chemiluminescence sensor  

International Nuclear Information System (INIS)

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy)_3"2"+ and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy)_3"2"+-doped silica nanoparticles and Au nanoparticles. UV-vis absorption spectroscopy, scanning electron microscopy (SEM), cyclic voltammetry and ECL were used to characterize the uniform growth of the multilayer film. Since Ru(bpy)_3"2"+ could still maintain its ECL property when doped into the silica nanoparticles, the as-prepared multilayer film could be used as an effective ECL sensor, and the sensor showed high sensitivity and good stability.

2008-09-20

421

Layer-by-layer assembly of functional silica and Au nanoparticles for fabricating electrogenerated chemiluminescence sensor  

British Library Electronic Table of Contents (United Kingdom)

We described the use of silica nanoparticles as building blocks for the immobilization of electrogenerated chemiluminescence (ECL) reagent Ru(bpy)32+ and the fabrication of layer-by-layer assembly film by alternating the deposition of the Ru(bpy)32+-doped silica nanoparticles and Au nanoparticles. UV-vis absorption spectroscopy, scanning electron microscopy (SEM), cyclic voltammetry and ECL were used to characterize the uniform growth of the multilayer film. Since Ru(bpy)32+ could still maintain its ECL property when doped into the silica nanoparticles, the as-prepared multilayer film could be used as an effective ECL sensor, and the sensor showed high sensitivity and good stability.

2008-01-01

422

Laser beam apparatus and method for analyzing solar cells  

Energy Technology Data Exchange (ETDEWEB)

A laser beam apparatus and method for analyzing, inter alia, the current versus voltage curve at the point of illumination on a solar cell and the open circuit voltage of a solar cell. The apparatus incorporates a lock-in amplifier, and a laser beam light chopper which permits the measurement of the AC current of the solar cell at an applied DC voltage at the position on the solar cell where the cell is illuminated and a feedback scheme which permits the direct scanning measurements of the open circuit voltage. The accuracy of the measurement is a function of the intensity and wavelength of the laser light with respect to the intensity and wavelength distribution of sunlight and the percentage the dark current is at the open circuit voltage to the short circuit current of the solar cell.

1980-01-01

423

Laparoscopic approach of a nonparasitic splenic cyst; Abordagem videolaparoscopica de cisto esplenico nao parasitario  

Energy Technology Data Exchange (ETDEWEB)

A rare case of primary splenic cyst is shown in a young woman who had a left subcostal abdominal pain. Abdominal echography and CT scan revealed a cyst of the anterior aspect of the spleen. A sorologic test for hidatic disease was negative. On the basis of a presumed diagnostic of nonparasitic cyst, the patient was referred to a laparoscopic decapsulation with excision of the cysts wall not covered by splenic tissue. The patient was discharged 24 hours later. Histological report revealed epidermoid cyst. The laparoscopic approach has being recently considered an effective and less invasive alternative in the treatment of splenic diseases. We demonstrated that it should be considered for the treatment of splenic cysts present in a superficial location, with the advantage of organ preservation. (author)

2000-10-01

424

Laboratory evaluation of pipeline girth weld imperfections to determine their acceptability in sour gas service  

Energy Technology Data Exchange (ETDEWEB)

The influence of common welding defects such as internal under-cut, incomplete penetration of the root bead, internal concavity and hollow bead have been evaluated in a sour environment. Tests were performed on samples cut from actual pipeline welds. The individual defects were subjected to slow strain rate testing. The samples were then examined by metallography, scanning electron microscopy, and hardness testing. It was established that a threshold stress intensity exists for sulphide stress cracking. The test results were compared to those obtained from samples of the weld and pipe which did not contain any defects. This comparison indicated that the metallurgical variations associated with the presence of a weld are the main factor for sulphide stress cracking rather than any specific defects or geometry. 5 tabs., 9 figs.

1992-12-31

425

LDEF impact craters formed by carbon-rich impactors  

International Nuclear Information System (INIS)

Two small craters (number 74, 119 microns, and number 31, 158 microns in diameter) with depth to diameter ratios of about 0.59 and 0.8, respectively, were found in Al from the Long Duration Exposure Facility (LDEF) experiment tray A11EOOF. Both craters have residues concentrated in the crater bottoms, along the walls, and on top of the overturned rims. Low voltage scanning electron electron microscopy, Auger electron spectroscopy, time of flight secondary ion mass spectroscopy and energy dispersive x-ray spectroscopy were used to obtain high resolution imagery and elemental analysis. Analyses indicate that the impactor for both craters was carbon-rich, as the residues contain mostly C. Silicon, S, and F in low concentrations are present on the Al surface away from the craters and may be, in part, contaminants.

1991-06-01

426

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

427

Investigation on the effect of cellulosic nanoparticles' morphology on the properties of natural rubber based nanocomposites  

British Library Electronic Table of Contents (United Kingdom)

Cellulose whiskers and microfibrillated cellulose (MFC) were extracted from the rachis of date palm tree and characterized. These cellulosic nanoparticles were used as reinforcing phase to prepare nanocomposite films using latex of natural rubber as matrix. These films were obtained by the casting/evaporation method. The properties of the ensuing nanocomposite films were investigated using differential scanning calorimetry, toluene and water uptake experiments, dynamic mechanical analysis and tensile tests. The stiffness of the natural rubber was significantly increased above its glass-rubber transition temperature upon nanoparticles addition. The reinforcing effect was shown to be higher for nanocomposites with MFC compared to whiskers. It was ascribed to the higher aspect ratio and possi...

2010-01-01

428

Investigation of Tumor-Peritoneal Interactions in the Pathogenesis of Peritoneal Metastases using a Novel Ex Vivo Peritoneal Model1  

British Library Electronic Table of Contents (United Kingdom)

BackgroundPeritoneal metastasis occurs in up to 30% of patients with gastric cancer. The aim of this experimental study is to develop and validate a novel ex vivo model of the human peritoneum to better identify factors involved in the development of peritoneal metastasis in order to improve its management and prognosis. MethodsPeritoneal discs harvested from hernia sacs obtained at inguinal hernia surgery were suspended in media using Teflon rings. Viability of the tissue was investigated using MTS assay, light and scanning electron microscopy (LM and SEM) over 72 h. To assess validity of the model, phenotypic changes in tumor cells were investigated. Changes in matrix metalloproteinases (MMP)-2 and -9 activities in HGC and AGS gastric adenocarcinoma cells after co-culture were investigat...

2010-01-01

429

Investigating the effect of an arterial hypertension drug on the structural properties of plasma protein  

British Library Electronic Table of Contents (United Kingdom)

Propanolol is a betablocker drug used in the treatment of arterial hypertension related diseases. In order to achieve an optimal performance of this drug it is important to consider the possible interactions of propanolol with plasma proteins. In this work, we have used several experimental techniques to characterise the effect of addition of the betablocker propanolol on the properties of bovine plasma fibrinogen (FB). Differential scanning calorimeter (DSC), circular dichroism (CD), dynamic light scattering (DLS), surface tension techniques and atomic force microscopy (AFM) measurements have been combined to carry out a detailed physicochemical and surface characterization of the mixed system. As a result, DSC measurements show that propranolol can play two opposite roles, either acting ...

2011-01-01

430

Inhibiting pitting corrosion in carbon steel exposed to dilute radioactive waste slurries  

Energy Technology Data Exchange (ETDEWEB)

Dilute caustic high-level radioactive waste slurries can induce pitting corrosion in carbon steel. Cyclic potentiodynamic polarization tests were conducted in simulated and actual waste solutions to determine minimum concentrations of sodium nitrate which inhibit pitting in ASTM A537 class 1 steel exposed to these solutions. Susceptibility to pitting was assessed through microscopic inspection of specimens and inspection of polarization scans. Long-term coupon immersion tests were conducted to verify the nitrite concentrations established by the cyclic potentiodynamic polarization tests. The minimum effective nitrite concentration is expressed as a function of the waste nitrate concentration and temperature.

1991-01-01

431

In situ synthesis of silver chloride nanoparticles into bacterial cellulose membranes  

British Library Electronic Table of Contents (United Kingdom)

In situ synthesis of silver chloride (AgCl) nanoparticles was carried out under ambient conditions in nanoporous bacterial cellulose (BC) membranes as nanoreactors. The growth of the nanoparticles was readily obtained by alternating dipping of BC membranes in the solution of silver nitrate or sodium chloride followed by a rinse step. X-ray diffraction (XRD) patterns indicated the existence of AgCl nanoparticles in the BC and scanning electron microscopy (SEM) images showed that the AgCl nanoparticles well dispersed on the surface of BC and penetrated into the BC network. The AgCl nanoparticle-impregnated BC membranes exhibited high hydrophilic ability and strong antimicrobial activity against Escherichia coli (Gram-negative) and Staphylococcus aureus (Gram-positive). The preparative proced...

2009-01-01

432

Immunofluorescence analysis of the internal brain anatomy of Nereis diversicolor (Polychaeta, Annelida)  

British Library Electronic Table of Contents (United Kingdom)

Comparative analyses of neuroanatomical characters can make valuable contributions to the inference of phylogenetic relationships. Whereas investigations in this field are numerous for arthropods, in-depth studies on other protostomes are sparse. Here, we provide a survey of the internal neuroarchitecture of the brain of the aciculate ragworm Nereis diversicolor (Polychaeta, Annelida). Descriptions are based on confocal laser scanning microscope analyses of brain sections labeled with the nuclear marker DAPI and antibodies raised against FMRF-amide, serotonin, and histamine. Autofluorescence of the nervous tissue has been utilized to further elucidate the anatomical structures of the brain. The architecture of two major brain compartments, i.e., the paired mushroom bodies and the central o...

2008-01-01

433

Hydriding properties of a mechanically milled Mg-50 wt.% ZrFe{sub 1.4}Cr{sub 0.6} composite  

Energy Technology Data Exchange (ETDEWEB)

The ball-milling method was used to produce Mg-50 wt.% ZrFe{sub 1.4}Cr{sub 0.6} composite. The thermodynamic, kinetic, and cycling properties, as well as the resistance to oxidation were examined. This composite possesses excellent kinetic properties, even at moderate temperature. Scanning electron microscopy, energy-dispersive spectrum, transmission electron microscopy and X-ray diffraction were used to characterize the composite before and after hydriding. The fine ZrFe{sub 1.4}Cr{sub 0.6} particles covering Mg particles acting as a ''catalytic film'', a significant amount of imperfections and some alloy powder in the Mg matrix introduced by ball milling all contributed to the enhanced absorption/desorption rate. (orig.)

2000-02-02

434

Growth of ytterbium tartrate trihydrate crystals in silica and agar-agar gels and their characterization  

British Library Electronic Table of Contents (United Kingdom)

Single crystals of ytterbium tartrate trihydrate have been grown by gel method using silica and agar-agar gels as media of growth. The medium of growth influences the morphology of grown crystals, silica gel yielding single and polycrystalline in the form of spherulites whereas agar-agar gel leading to growth of single and twinned crystals. Materials grown as single crystals have been characterized by using optical and scanning electron microscopy (SEM), EDAX, XRD, FT-IR, CHN and thermogravimetric techniques. The stoichiometry of the grown single crystals is suggested to be Yb(C4H4O6) (C4H5O6).3H2O. The FT-IR spectrum shows the presence of singly as well as doubly ionized tartrate ligands. Results of thermal analysis indicate that the material is thermally stable up to a temperature of 200...

2006-01-01

435

GABAB Receptors Modulate NMDA Receptor Calcium Signals in Dendritic Spines  

British Library Electronic Table of Contents (United Kingdom)

Summary Metabotropic GABAB receptors play a fundamental role in modulating the excitability of neurons and circuits throughout the brain. These receptors influence synaptic transmission by inhibiting presynaptic release or activating postsynaptic potassium channels. However, their ability to directly influence different types of postsynaptic glutamate receptors remains unresolved. Here we examine GABAB receptor modulation in layer 2/3 pyramidal neurons from the mouse prefrontal cortex. We use two-photon laser-scanning microscopy to study synaptic modulation at individual dendritic spines. Using two-photon optical quantal analysis, we first demonstrate robust presynaptic modulation of multivesicular release at single synapses. Using two-photon glutamate uncaging, we then reveal that GABAB r...

2010-01-01

436

Focused ion beam preparation of inclined planes in semiconductor materials  

International Nuclear Information System (INIS)

Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).

437

Focused ion beam (FIB) milling of electrically insulating specimens using simultaneous primary electron and ion beam irradiation  

International Nuclear Information System (INIS)

There is currently great interest in combining focused ion beam (FIB) and scanning electron microscopy technologies for advanced studies of polymeric materials and biological microstructures, as well as for sophisticated nanoscale fabrication and prototyping. Irradiation of electrically insulating materials with a positive ion beam in high vacuum can lead to the accumulation of charge, causing deflection of the ion beam. The resultant image drift has significant consequences upon the accuracy and quality of FIB milling, imaging and chemical vapour deposition. A method is described for suppressing ion beam drift using a defocused, low-energy primary electron beam, leading to the derivation of a mathematical expression to correlate the ion and electron beam energies and currents with other parameters required for electrically stabilizing these challenging materials.

2007-02-07

438

Fluoride phosphate Li{sub 2}CoPO{sub 4}F as a high-voltage cathode in Li-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

As a new high-voltage cathode candidate for post 4V cathodes, ordered-olivine LiCoPO{sub 4} and fluoride phosphate, Li{sub 2}CoPO{sub 4}F were synthesized by solid-state reaction. Their structures were identified by neutron diffraction. The 5V discharge profiles were demonstrated using coin-type cells. Two important issues for commercial use, metal dissolution and oxygen release at elevated temperatures, were also tested with an atomic absorption spectrophotometer and differential scanning calorimeter, respectively. (author)

2005-08-26

439

Fabrication of self-aligned aluminum gate polysilicon thin-film transistors using low-temperature crystallization process  

Energy Technology Data Exchange (ETDEWEB)

The performance of scanning driver circuits fabricated with self-aligned aluminum gate polysilicon thin-film transistors (TFT's) is demonstrated. After the gate electrode patterning, the fabrication process temperature is kept below 400degC to enable the use of aluminum gate electrodes. The low-temperature crystallization phenomenon, which occurs when protons are implanted simultaneously with boron or phosphorus dopants, is employed to eliminate the 600degC activation-annealing process. A maximum clock frequency of about 2.0 MHz is achieved when the driver operating voltage is 24 V and the TFT channel length is 12 [mu]m. (author).

1994-01-01

440

Fabrication of self-aligned aluminum gate polysilicon thin-film transistors using low-temperature crystallization process  

International Nuclear Information System (INIS)

The performance of scanning driver circuits fabricated with self-aligned aluminum gate polysilicon thin-film transistors (TFT's) is demonstrated. After the gate electrode patterning, the fabrication process temperature is kept below 400degC to enable the use of aluminum gate electrodes. The low-temperature crystallization phenomenon, which occurs when protons are implanted simultaneously with boron or phosphorus dopants, is employed to eliminate the 600degC activation-annealing process. A maximum clock frequency of about 2.0 MHz is achieved when the driver operating voltage is 24 V and the TFT channel length is 12 #mu#m. (author).

441

Extensions to the VME hardware and software standards for the physics community  

Energy Technology Data Exchange (ETDEWEB)

With the ubiquitous availability of commercial VME modules and interface chips many experiments in all branches of Experimental Physics are turning to VME as the module packaging and backplane protocol of choice for application specific modules. The current VME backplane, electrical, and mechanical standards are clearly lacking when it comes to implementing the analogue and digital front end modules that Physics experiments rely on to provide the needed high speed and intelligent solutions to their data collection requirements. To address these needs the European ESONE and American VME-P committees are collaborating with the ANSII and ISO standards committees, and the VME VITA/VSO manufacturers associations, to define standard extensions to the VME protocols for such HEP needs as ``sparse data scans``, standard uses and implementations of previously user defined pins and connectors, standardization of the 9U form factor VME cards etc. This paper reports on the ...

1995-10-01

442

Explosives sensor  

Energy Technology Data Exchange (ETDEWEB)

A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this device's construction and advantages are discussed in ...

1987-01-01

443

Experimental investigation and modelling of heat capacity, heat of fusion and melting interval of rocks  

Energy Technology Data Exchange (ETDEWEB)

The heat capacity and heat of fusion were measured for a number of minerals using differential scanning calorimetry (DSC). The DSC measurements showed that the heat of fusion for the minerals is very low compared to the heat of fusion for pure crystalline phases reported elsewhere. A model for the melting behaviour of mineral materials in terms of melting interval, heat capacities and heat of fusion has been developed. The only model input is the chemical composition of the mineral material. The model was developed to be implemented in a detailed model of a cupola furnace, thus the focus for the development was not only precision but also to obtain a model that was continuous and differentiable. The model is based on several different submodels that each covers a part of the heating and melting of rocks. Each submodel is based on large amounts of empirical data. Comparison of the model and the DSC measurements showed reasonable agreement for the model to be used ...

2003-11-28

444

Evaluation of soil moisture derived from passive microwave remote sensing over agricultural sites in Canada using ground-based soil moisture monitoring networks  

British Library Electronic Table of Contents (United Kingdom)

Passive microwave soil moisture datasets can be used as an input to provide an integrated assessment of climate variability as it relates to agricultural production. The objective of this research was to examine three passive microwave derived soil moisture datasets over multiple growing seasons in contrasting Canadian agricultural environments. Absolute and relative soil moisture was evaluated from two globally available datasets from the Advanced Microwave Scanning Radiometer for EOS (AMSR-E) sensor using different retrieval algorithms, as well as relative soil wetness at a weekly scale from the Special Sensor Microwave/Imager (SSM/I) sensor. At a daily scale, the Land Parameter Retrieval Model (LPRM) provides a better estimate of surface soil moisture conditions than the National Snow a...

2010-01-01

445

Evaluation of cost effectiveness for conservative and active management strategies for acoustic neuroma  

British Library Electronic Table of Contents (United Kingdom)

Clin. Otolaryngol. 2009, 34, 438-446. Objective: To determine whether economic costs associated with a conservative management strategy for unilateral acoustic neuroma offer an economic advantage over active management options. Design: Cost and sensitivity analysis on a prospective cohort. Setting: Single centre study within a tertiary referral centre in Toronto, Canada. Participants: 72 patients (32 males, 40 females) aged 36 to 78 years with unilateral acoustic neuroma were assigned initially to a conservative management strategy. Entry criteria were small tumour size (less than 15mm in the cerebellopontine angle), patient preference and/or significant co-morbidity. Interventions: MRI scanning was performed every 6 months for the first year, annually subsequently and then every 2-3 years...

2009-01-01

446

Evaluation of CO2 adsorption capacity of solid sorbents  

British Library Electronic Table of Contents (United Kingdom)

The CO2 adsorption capacity of the low-cost solid sorbents of waste tire char (TC) and chicken waste char (CW) was compared with commercial active carbon (AC) and 5?? zeolite (ZA) using thermogravimetric analysis (TG), pressurized TG, and differential scanning calorimetry (DSC). The sorbents were degassed in a TG up to 150??C to release all gases on the surface of the sample, then cooled down to the designed temperature for adsorption. TG results indicated that the CO2 adsorption capacity of TC was higher than that of CW, but lower than those of AC and ZA. The maximum adsorption rate of TC at 50??C was 0.61% min?1, lower than that of AC, but higher than that of CW, 0.44% min?1. The maximum adsorption rate of ZA at 50??C was 3.1% min?1. When the pressure was over 4?bar, the adsorption rate ...

2011-01-01

447

Enhancement of convective heat transfer by using microencapsulated PCM slurry  

Energy Technology Data Exchange (ETDEWEB)

As a method to make use of a high latent heat of a liquid-solid phase change material in a confined convective heat transfer, a phase change material, lauric acid, was encapsulated in a tiny hollow sphere, and mixed with water, forming a slurry of microencapsulated phase-change material (MCPCM slurry). Four different sizes (200, 100, 50, and 25 {mu}m ID) of MCPCMs were tested in this study. Thermal characteristics of the pure lauric acid and lauric acid MCPCMs were tested by a differential scanning calorimeter. Viscosity of the slurries of water and the capsules was measured by a rotating viscometer. The slurries were also tested in a convective-heat-transfer-test apparatus. (author). 11 refs., 5 figs., 1 tab.

1998-11-01

448

Embryo-damage induced nucleation of microcracks in an aluminum alloy under impact loading  

Energy Technology Data Exchange (ETDEWEB)

The nucleation of microdamage under dynamic loading was investigated through planar impact experiments accomplished with a light gas gun. The microscopic observation of recovered and sectioned specimens showed that microcracks were nucleated only by cracking of brittle particles inside material. However, for comparison the in situ static tensile tests on the same material conducted with a scanning electron microscope showed that the microcracks were nucleated by many forms those were fracture of ductile matrix, debonding particles from matrix and cracking of brittle particles. The quantitative metallographic observations of the specimens subjected to impact loading showed that most of the cracked particles were situated on grain boundaries of the aluminum matrix. These facts suggested the concept of critical size and incubation time of submicroscopic cavities in the dynamic case and the mechanism of embryo-damage induced nucleation by fracture of brittle particles ...

1995-06-01

449

Electrosynthesis of adherent poly(3-amino-1,2,4-triazole) films on brass prepared in nonaqueous solvents  

Energy Technology Data Exchange (ETDEWEB)

The kinetics of the electropolymerization of 3-amino-1,2,4-triazole on a brass substrate in alkaline solution containing methanol was investigated using cyclic polarization, chronoamperometry, electrochemical impedance techniques and scanning electronic microscopy. The polymeric film was prepared by successive cycles of potential of a 60Cu-Zn electrode between 0 and 1.6 V. During the second cycle, the oxidation peak of the monomer disappears indicating the formation of the insulating film. We have also shown that the monomer oxidation reaction is essentially irreversible and controlled by a diffusion process. The protective effect of the film formed on brass has been studied in a 3%NaCl and 3%NaCl + S{sup 2-} solution. The results showed important inhibition efficiency, about 96% for 4 h of testing time.

2008-06-15

450

Electrosynthesis of adherent poly(3-amino-1,2,4-triazole) films on brass prepared in nonaqueous solvents  

British Library Electronic Table of Contents (United Kingdom)

The kinetics of the electropolymerization of 3-amino-1,2,4-triazole on a brass substrate in alkaline solution containing methanol was investigated using cyclic polarization, chronoamperometry, electrochemical impedance techniques and scanning electronic microscopy. The polymeric film was prepared by successive cycles of potential of a 60Cu-Zn electrode between 0 and 1.6V. During the second cycle, the oxidation peak of the monomer disappears indicating the formation of the insulating film. We have also shown that the monomer oxidation reaction is essentially irreversible and controlled by a diffusion process. The protective effect of the film formed on brass has been studied in a 3%NaCl and 3%NaCl+S2- solution. The results showed important inhibition efficiency, about 96% for 4h of testing ...

2008-01-01

451

Electrodeposition and characterization of Ni-Co/SiC nanocomposite coatings  

British Library Electronic Table of Contents (United Kingdom)

Ni-Co/SiC nanocomposite coatings were electrodeposited in a modified watt type of Ni-Co bath containing 20nm SiC particles to be codeposited. Potentiodynamic polarization tests were conducted to study the effect of the SiC particulates on the electrodeposition of Ni and Co. Scanning electron microscopy was used to assess the morphology of the Ni-Co alloy and Ni-Co/SiC nanocomposite coatings. The distribution of the particulates in the matrix was considered by means of transmission electron microscopy. Applying nanomechanical testing instruments coupled to atomic force microscopy, mechanical properties of the alloy and composite coatings were studied and compared. The presence of 11vol.% SiC in the Ni-Co matrix increased hardness more than 60%. The average depth of scratch in the mentioned ...

2011-01-01

452

Electrochemical performance of flowerlike CaSnO{sub 3} as high capacity anode material for lithium-ion batteries  

Energy Technology Data Exchange (ETDEWEB)

Nanosized CaSnO{sub 3} is synthesized by a hydrothermal process and characterized by X-ray diffraction (XRD), Raman spectroscopy, and scanning electron microscopy (SEM). The SEM observation shows the sample has a porous flowerlike morphology. The electrochemical results exhibit that the stable and reversible capacity of 547 mAh g{sup -1} is obtained after 50 cycles at 60 mA g{sup -1} (0.1 C) and the corresponding charge capacity is determined to be 316 mAh g{sup -1} at the current density of 2.5 C. Cyclic voltammetry and electrochemical impedance spectroscopy data are analyzed to complement the galvanostatic results. The observed excellent performance is attributed to the porous structure and large surface area of flowerlike CaSnO{sub 3}.

2010-04-30

453

Electrochemical method for the synthesis of silver nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

The article deals with a novel electrochemical method of preparing long-lived silver nanoparticles suspended in aqueous solution as well as silver powders. The method does not involve the use of any chemical stabilising agents. The morphology of the silver nanoparticles obtained was studied using transmission electron microscopy, scanning electron microscopy, atomic force microscopy and dynamic light scattering measurements. Silver nanoparticles suspended in water solution that were produced by the present technique are nearly spherical and their size distribution lies in the range of 2 to 20 nm, the average size being about 7 nm. Silver nanoparticles synthesised by the proposed method were sufficiently stable for more than 7 years even under ambient conditions. Silver crystal growth on the surface of the cathode in the electrochemical process used was shown to result in micron-sized structures consisting of agglomerated silver nanoparticles with the sizes below 40 ...

2009-07-15

454

Electrochemical deposition of indium sulfide thin films using two-step pulse biasing  

British Library Electronic Table of Contents (United Kingdom)

Indium sulfide thin films were deposited onto indium-tin-oxide coated glass substrate by electrochemical deposition from an aqueous solution containing In2 (SO4) 3 and Na2S2O3. The deposition conditions were optimized on the basis of data obtained by scanning electron microscope, Auger electron spectroscopy and optical transmission measurements. Furthermore, the photosensitivity of the films was observed by means of photoelectrochemical measurements, which confirmed that the indium sulfide showed n-type conduction. The X-ray diffraction and Raman studies revealed that the as-grown films were amorphous or nanocrystalline in nature and became polycrystalline In2S3 after annealing.

2008-01-01

455

Electrochemical behavior of antimony and electrodeposition of Mg-Li-Sb alloys from chloride melts  

British Library Electronic Table of Contents (United Kingdom)

The electrochemical behavior of Sb(III) ions was investigated in LiCl-KCl molten salt at 673K. The reaction mechanism and transport parameters of electroactive species were determined by transient electrochemical techniques (such as cyclic voltammetry, square wave voltammetry, chronopotentiometry and chronoamperometry) at a molybdenum electrode. The results showed that electrochemical reduction of Sb(III) in LiCl-KCl melts occurred in a reaction step with an exchange of three electrons. A voltammogram with a different scan rate in LiCl-KCl containing 1.45x10^-^4molcm^-^3 SbCl3 showed that the deposition/dissolution reaction of Sb(III) ions was not completely reversible. The diffusion coefficient of Sb(III) ions was 1.65(+/-0.01)x10^-^5cm^-^2s^-^1 at 673K. The electroreduction of Sb(III) io...

2011-01-01

456

Electrical properties and x-ray diffraction of wood and wood plastic composite (WPC)  

Energy Technology Data Exchange (ETDEWEB)

Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).

1991-01-01

457

Effects of coolant chemistry on corrosion of 3003 aluminum alloy in automotive cooling system  

British Library Electronic Table of Contents (United Kingdom)

In this work, effects of coolant chemistry, including concentrations of chloride ions and ethylene glycol and addition of various ions, on corrosion of 3003 Al alloy were investigated by electrochemical impedance spectroscopy measurements and scanning electron microscopy characterization. In chloride-free, ethylene glycol-water solution, a layer of Al-alcohol film is proposed to form on the electrode surface. With the increase of ethylene glycol concentration, more Al-alcohol film is formed, resulting in the increase in film resistance and charge-transfer resistance. In the presence of Cl- ions, they would be involved in the film formation, decreasing the stability of the film. In 50% ethylene glycol-water solution, the threshold value of Cl- concentration for pitting initiation is within ...

2010-01-01

458

Effects of carbon fiber surface treatment on the tribological properties of 2D woven carbon fabric/polyimide composites  

British Library Electronic Table of Contents (United Kingdom)

Polyacrylonitrile (PAN)-based carbon fabric (CF) was modified with strong HNO3 oxidation and then introduced into polyimide (PI) composites. The friction and wear properties of the carbon fabric reinforced polyimide composites (CFRP), sliding against GCr15 stainless steel rings, were investigated on an M-2000 model ring-on-block test rig under dry sliding. Experimental results revealed that the carbon fiber surface treatment largely reduced the friction and wear of the CFRP. Compared with the untreated ones, the surface-modified CF can enhance the tribological properties of CFRP efficiently due to the improved adhesion between the CF and the PI matrix. Scanning electron microscope (SEM) and X-ray photoelectron spectroscopy (XPS) study of the carbon fiber surface showed that the fiber surfa...

2009-01-01

459

Effect of tungsten on the corrosion behavior of sulfuric acid-resistant steels for flue gas desulfurization system  

British Library Electronic Table of Contents (United Kingdom)

Flue gas desulfurization systems (FGDs) are operated in severely corrosive environments that cause sulfuric acid dew-point corrosion. The corrosion behavior of low-alloy steels was tested using electrochemical techniques (electrochemical impedance spectroscopy, potentiodynamic tests, potentiostatic tests), and the corrosion products were analyzed by scanning electron microscopy and X-ray photoelectron spectroscopy. The electrochemical results showed that alloying W with small amounts of Sb, Cu, and Co improves the corrosion resistance of steels. The results of surface analyses showed that the surface of the steels alloyed with W consisted of W oxides and higher amounts of Sb and Cu oxides. This suggests that the addition of W promotes the formation of a protective WO3 film, in addition to ...

2011-01-01

460

Effect of milling process on the core-shell structures and dielectric properties of fine-grained BaTiO3-based X7R ceramic materials  

British Library Electronic Table of Contents (United Kingdom)

Fine-grained BaTiO3-based X7R ceramic materials were prepared and the effects of milling process on the core-shell structures and dielectric properties were investigated using scanning electron microscope, transmission electron microscope, and energy dispersive spectroscopy (EDS). As the milling time extends, the dielectric constant of the ceramics increases, whereas the temperature coefficient of capacitance at 125degreeC drops quickly. The changes in dielectric properties are considered relevant to the microstructure evolution caused by the milling process. Defects on the surface of BaTiO3 particles increase because of the effects of milling process, which will make it easier for additives to diffuse into the interior grains. As the milling time increases, the shell region gets thicker a...

2009-01-01

461

Effect of Al and AlP on the microstructure of Mn-30 wt.%Si alloy  

Energy Technology Data Exchange (ETDEWEB)

Effect of Al and AlP particles on the microstructure of near eutectic Mn-Si alloy (Mn-30 wt.%Si) was studied by Electron Probe Micro-analyzer (EPMA) and Differential Scanning Calorimeter (DSC). Crystal lattice correspondence analyses show that both Al and AlP have good lattice matching coherence relationships with MnSi phase, and the addition of Al and AlP particles results in an abnormal eutectic structure, i.e. the eutectic constitution MnSi and Mn{sub 5}Si{sub 3} precipitate separately: MnSi precipitates firstly, and then the Mn{sub 5}Si{sub 3} phase.

2008-04-15

462

Drug delivery with upconversion nanoparticles for multi-functional targeted cancer cell imaging and therapy  

British Library Electronic Table of Contents (United Kingdom)

Upconversion nanoparticles (UCNPs) with unique multi-photon excitation photoluminescence properties have recently been intensively explored as novel contrast agents for low-backgroundbiomedical imaging. In this work, we functionalize UCNPs with a polyethylene glycol (PEG) grafted amphiphilic polymer. The PEGylated UCNPs are loaded with a commonly used chemotherapy molecule, doxorubicin (DOX), by simple physical adsorption via a supramolecular chemistry approach for intracellular drug delivery. The loading and releasing of DOX from UCNPs are controlled by varying pH, with an increased drug dissociation rate in acidic environment, favorable for controlled drug release. Upconversion luminescence (UCL) imaging by a modified laser scanning confocal microscope reveals the time course of intracel...

2011-01-01

463

Dosimetry of iodine-123 iomazenil in humans  

International Nuclear Information System (INIS)

The distribution of the central benzodiazepine receptor specific ligand iodine-123 iomazenil was investigated in seven human adults from whole-body scans, blood samples and urine collected up to 24 h after injection. Using 12 source organs, the MIRD method was applied to calculate the absorbed radiation dose of the radioligand in various organs. The urinary bladder wall (0.15 mGy/MBq), lower large intestinal wall (0.071 mGy/MBq) testes (0.044 mGy/MBq) and upper large intestined wall (0.038 mGy/MBq) received the highest absorbed doses. The average effective dose equivalent of "1"2"3I-IBZM for adults was estimated to be 0.033 mSv/MBq. (orig.).

464

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-12-01

465

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-01-01

466

Development of nanocomposite polymer materials for electrical and electronic applications  

International Nuclear Information System (INIS)

Some results and experimental procedures of laboratory are reported in the frame of researches conducted for the development of new nanostructured composite materials. These new materials, which are constituted by an organic phase: the polymer and an inorganic phase: the silicate, are being strongly investigated nowadays so it is expected that they could provide, among other, better electrical insulation properties and flame-delay in electrical and electronic applications. The laboratory experimental work has been developed from two families of polymers, thermoplastics and thermosets and clays silicates providing lamellar type. There are now some preliminary results, such as obtaining thin films of these nanocomposite materials, their complete characterization by X-ray diffraction, scanning microscopy and thermogravimetric analysis, they do well to wait for future research activities. (author)

2007-01-01

467

Development of liquid metal ion sources, focused ion beam and their applications  

International Nuclear Information System (INIS)

To suit the needs of development for manufacture VLSI, we started to investigate liquid metal ion sources (LMIS) and focused ion beam (FIB) in 1984. Many kinds of emitters viz. neddle type, co-axial type and capillary type of Ga and Au LMIS and three kinds of eutectic alloys LMIS (Au-Si, Au-Si-Be, Pd-Ni-Si-Be-B) have been tested. A program which can calculate focused ion guns has been written. Four kinds of foused ion guns have been operated, a fine beam with diametic 0.1 #mu#m is obtained. Using the FIB a scanning ion microscope has been constructed. Some tests of etching and self-developing of nitrocellulose are described. (author).

468

Development of high-field STM for 18 T cryocooled superconducting magnet  

International Nuclear Information System (INIS)

To study the nanoscale electronic order in strongly correlated electron systems and vortex states in high-Tc superconductors in high magnetic fields, we have developed scanning tunneling microscopy (STM) for the 18 T cryocooled superconducting magnet (18T-CSM). The test results of the STM operation in the 18T-CSM at room temperature indicate that our STM has a good atomic resolution up to 18 T when we use the nonmagnetic vibration-isolation table which reduce the vibration noise from the cryocoolers of the 18T-CSM. In this paper, we report on the design of the high-field STM system for large-scale magnets and its performance.

2009-02-01

469

Development of a Full Body CAD Dataset for Computational Modeling: A Multi-modality Approach  

British Library Electronic Table of Contents (United Kingdom)

The objective of this study was to develop full body CAD geometry of a seated 50th percentile male. Model development was based on medical image data acquired for this study, in conjunction with extensive data from the open literature. An individual (height, 174.9?cm, weight, 78.6???0.77?kg, and age 26?years) was enrolled in the study for a period of 4?months. 72 scans across three imaging modalities (CT, MRI, and upright MRI) were collected. The whole-body dataset contains 15,622 images. Over 300 individual components representing human anatomy were generated through segmentation. While the enrolled individual served as a template, segmented data were verified against, or augmented with, data from over 75 literature sources on the average morphology of the human body. Non-Uniform Rational...

2011-01-01

470

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

471

Design and control of six degree-of-freedom active vibration isolation table.  

Science.gov (United States)

A six-axis active vibration isolation system (AVIS) is designed by using the direct driven guide and ball contact mechanisms in order to have no cross-coupling between actuators. The point contact configuration gives an advantage of having an easy assembly of eight voice coil actuators to an upper and a base plate. A voice coil actuator is used since it can provide a large displacement and sufficient bandwidth required for vibration control. The AVIS is controlled considering the effect of flexible vibration mode in the upper plate and velocity sensor dynamics. A loop shaping technique and phase margin condition are applied to design a vibration controller. The performances of the AVIS are investigated in the frequency domain and finally validated by comparing with the passive isolation system. The scanning profiles of the specimen are compared together by using the atomic force microscope. The robustness of the AVIS is verified by showing the impulse response. ...

2010-03-01

472

Degradation of the corrosion resistance of anodic oxide films through immersion in the anodising electrolyte  

Energy Technology Data Exchange (ETDEWEB)

The deterioration of AA2024, AA6061 and AA7475 anodised in an environmentally-compliant tartaric acid/sulphuric acid electrolyte has been examined as a function of the immersion time in the electrolyte after termination of anodising. By transmission electron microscopy and scanning electron microscopy, degradation of the porous oxide film was qualitatively observed on AA2024. Electrochemical impedance spectroscopy revealed that AA2024 and AA7075 were more sensitive to prolonged immersion in the anodising electrolyte compared with AA6061, due to increased barrier layer thinning rates and increased susceptibility to localized corrosion. Salt spray tests confirmed the previous, indicating decay of anticorrosion performance for AA2024 and AA7075.

2010-07-15

473

Damage mechanisms around hardness indentations in Ti{sub 3}SiC{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

Microstructural observations of damage around indentations in Ti{sub 3}SiC{sub 2} are presented. The Vickers hardness decreased with increasing load and asymptotically approached 4 GPa at the highest loads. No indentation cracks were observed even at loads as high as 300 N. Preliminary strength versus indentation plots indicate that, at least for the large-grained material ({approx}100 {micro}m) studied here, Ti{sub 3}SiC{sub 2} is a damage-tolerant material able to contain the extent of microdamage to a small area around the indent. The following multiple energy-absorbing mechanisms have been identified from scanning electron micrographs of areas in the vicinity of the indentation: diffuse microcracking, delamination, crack deflection, grain push-out, grain pull-out, and the buckling of individual grains.

1997-02-01

474

Corrosion of gold bridgewire in electronic components  

Energy Technology Data Exchange (ETDEWEB)

Accelerated aging tests on gold bridgewired detonator assemblies to determine compatibility of the Au and Pd-In-Sn solder with the organic explosive, PENT, have revealed an unusual corrosion process. These tests, conducted at 74/sup 0/C and 54/sup 0/C indicated a preferential attack of the gold. A matrix of corrosion test units was established to study this corrosion problem with accelerating temperatures up to 100/sup 0/C. Scanning electron microscopy (SEM), energy dispersive x-ray (EDX), and x-ray diffraction techniques were used to determine the extent of the corrosion and identify the corrosion products. Results indicate the preferential attack of the gold was due to HCN formed by decomposition of the explosive powder (PETN) at high temperatures. Other associated reactions were also observed including subsequent attack of the solder by the gold corrosion product and degradation of the plastic header.

1986-01-01

475

Corrosion and drug release properties of EN-plating/PLGA composite coating on MAO film  

British Library Electronic Table of Contents (United Kingdom)

The electroless nickel plating/poly(dl-lactide-co-glycolide) composite coating (EN-plating/PLGA composite coating) was fabricated on the surface of the micro-arc oxidation (MAO) film of the magnesium alloy AZ81 to double control the corrosion and drug release in the hanks' solution. The EN-plating was fabricated on the MAO coating to improve the corrosion resistance by overlaying most pores and micro-cracks on the surface of the MAO film. Meanwhile, a double layered organic poly(dl-lactide-co-glycolide)/paclitaxel (PLGA/PTX) drug releasing coating with a top layered PLGA drug controlled releasing coating on EN plating was prepared to control the drug release rate by adjusting the different lactide: glycolide (LA:GA) ratio of PLGA. Scanning electron microscopy (SEM) and the X-ray powder dif...

2011-01-01

476

Correlation of myocardial TC-99m-MIBI perfusion SPECT with coronary angiography in Namazi hospital  

International Nuclear Information System (INIS)

Coronary heart disease is the leading cause of death specially among elderly. Coronary angiography is the best diagnostic method in the patients, but is unfortunately an invasive procedure with its inherent risks. Myocardial perfusion scan is a noninvasive and sensitive method for evaluation of Coronary artery disease and is suggested by many investigators in recent years. In this study, 64 patients who had a Tc99m-MIBI SPECT myocardial perfusion study at our department, underwent coronary angiography within 4 months. Correlation of the methods revealed that SPECT Tc99m -MIBI had a high sensitivity and specificity in our hand, which is comparable with international findings.

2004-04-27

477

Controlled manipulation of carbon nanopillars and cantilevers by focused ion beam  

International Nuclear Information System (INIS)

We explore a novel phenomenon of focused ion beam (FIB) induced bending of carbon nanopillars or cantilever structures. The bending occurs towards the ion beam during scanning. The explanation of this bending has been sought on the basis of a model which considers temperature rise and gradients caused by the impinging ion beam. The process is controllable and reversible, which makes it highly suitable for in situ manipulation to make desired 3D shapes by the piecewise bending of the nanopillars and cantilever structures during their fabrication using electron beam or FIB chemical vapor deposition (EB-CVD or FIB-CVD). Its usefulness in the fabrication of nanosize mechanical components has been demonstrated by making a branch structure from a single cantilever.

2008-05-21

478

Composition, morphology, properties of coal fly ash microspheres and their application for conditioning liquid radioactive waste  

International Nuclear Information System (INIS)

Using methods of the Moessbauer spectroscopy, scanning electron microscopy, and thermodynamic analysis of phase formation in silicate multi-component melts, the detailed study of composition, morphology, and properties of fly ash microspheres resulting from combustion of three coals (Irsha-Borodinskii, Kuznetskii and Ekibastuzskii) was carried out. About 60 microspherical products with an iron content of 2-94 wt.% Fe_2O_3 were obtained. The ranges of microsphere composition, suitable for liquid radioactive waste solidification in the forms of iron phosphate (36-94 wt.% Fe_2O_3) and aluminosilicate (2-20 wt.% Fe_2O_3) ceramics were determined. The possibility of producing porous materials and specific microspherical sorbents, based on coal fly ash cenospheres and their application for mobilisation of liquid radioactive waste solidification was demonstrated. (author)

479

Colour contrast in ballistic gelatine  

British Library Electronic Table of Contents (United Kingdom)

Gelatine is a reliable tissue simulant in wound ballistic experiments. The projectile penetrating the gelatine transfers energy and causes radial cracks according to the temporary cavity. Thus the crack length is a function of the energy spent in the medium. In practice the fissures are poorly contrasted for which reason an enhancement of contrast was searched. A series of six shoots with expanding bullets (9mmx19 Action-5, 9mmx19 Quick Defense 1, 5.56mmx45 Styx Action) was realized on 10% gelatine blocks at 4^oC temperature. Three blocks were marked with acryl paint on the front, three blocks were shot native. The blocks were cut in slices of 1cm thickness and optically scanned. The evaluation was performed according to Fackler's wound profile, the total crack length method and the polygo...

2010-01-01

480

Collection of athermal phonons into doped Ge thermistors using quasiparticle trapping  

Energy Technology Data Exchange (ETDEWEB)

We have developed a low-temperature particle detector that uses a novel quasiparticle trapping mechanism to funnel athermal phonon energy from an 80 mg Ge absorber into a 1.6 mg doped Ge thermistor via a superconducting Al film. We report on pulse height spectra obtained at 320 mK by scanning a {sup 241}Am alpha source along the device, and show that up to 20% of the energy deposited in the Ge absorber by a 5.5 MeV alpha particle interaction can be collected into a thermistor via quasiparticle trapping. We show that this device is sensitive to the position of an alpha particle interaction in the Ge absorber for interaction distances of up to 5 mm from a quasiparticle trap.

1995-05-15

481

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is necessary for an accurate prediction of the performance of a concentrating solar energy system.

1980-01-01

482

Chemically produced nanostructured ODS-lanthanum oxide-tungsten composites sintered by spark plasma  

British Library Electronic Table of Contents (United Kingdom)

High purity W and W-0.9La2O3 (wt.%) nanopowders were produced by a wet chemical route. The precursor was prepared by the reaction of ammonium paratungstate (APT) with lanthanum salt in aqueous solutions. High resolution electron microscopy investigations revealed that the tungstate particles were coated with oxide precipitates. The precursor powder was reduced to tungsten metal with dispersed lanthanum oxide. Powders were consolidated by spark plasma sintering (SPS) at 1300 and 1400degreeC to suppress grain growth during sintering. The final grain size relates to the SPS conditions, i.e. temperature and heating rate, regardless of the starting powder particle size. Scanning electron microscopy revealed that oxide phases were mainly accumulated at grain boundaries while the tungsten matrix ...

2011-01-01

483

Characterization of the product of the thiosulfate process for desulfurization of flue gases  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction, infrared spectroscopy, thermal analysis, scanning electron microscopy, and particle size analysis were used to characterize the product of the thiosulfate process. It was found to consist of a mixture of a solid solution of calcium sulfate in calcium sulfite hemihydrate, calcium sulfate dihydrate, and calcium carbonate. Reactions taking place on heating the byproduct were identified in oxidizing and reducing atmospheres. Pure calcium sulfite hemihydrate as well as solid solutions of CaSO[sub 4] in CaSO[sub 3] [center dot] (1/2)H[sub 2]O with different sulfate concentrations were synthesized in the laboratory. Thermal analyses of pure solid solutions proved that the higher the sulfate content, the higher is the dehydration temperature. Accordingly, taking SO[sub 4][sup 2[minus

1994-05-01

484

Characterization of physically vapor deposited AF2400 thin films  

Energy Technology Data Exchange (ETDEWEB)

Anti-reflective coatings made with Teflon AF2400 had the highest damage thresholds recorded for physical vapor deposited coatings at the Lawrence Livermore National Laboratory damage facility. Physical vapor deposited layers of Teflon AF2400, a perfluorinated amorphous polymer, maintained the bulk optical properties of a high transmittance from 200 nm to 1600 nm, and a low refractive index. In addition, the refractive index can be intentionally reduced by control of two common deposition parameters, deposition rate and substrate temperature. Scanning electron microscopy and nuclear magnetic resonance observations indicated that morphological changes caused the variations in the refractive index rather than compositional changes. The coatings adhered to fused silica and silicon wafers under normal laboratory handling conditions.

1993-11-01

485

Characterization of All-Chromium Tunnel Junctions and Single Electron Tunneling Devices Fabricated by Direct-Writing Multilayer Technique  

CERN Document Server

We report about the fabrication and analysis of the properties of Cr/CrO_x/Cr tunnel junctions and SET transistors, prepared by different variants of direct-writing multilayer technique. In all cases, the CrO_x tunnel barriers were formed in air under ambient conditions. From the experiments on single junctions, values for the effective barrier height and thickness were derived. For the Cr/CrO_x/Cr SET transistors we achieved minimal junction areas of 17 x 60 nm^2 using a scanning transmission electron microscope for the e-beam exposure on Si_3N_4 membrane substrate. We discuss the electrical performance of the transistor samples as well as their noise behavior.

1999-01-01

486

Calcified metastases of the kidney. Etiology, pathogenesis, CT findings and diagnostic problems; Metastasi renali calcificate: eziologia, patogenesi, aspetti con tomografia computerizzata e diagnostica differenziale  

Energy Technology Data Exchange (ETDEWEB)

Aim of the work was to describe computerised tomography (CT) findings of calcified renal metastases focusing on differential diagnosis problems. Abdominal CT scans of 8000 patients with tumor, performed from 1984 to 1998, have been retrospectively reviewed. [Italian] Scopo del lavoro e' quello di descrivere gli aspetti con tomografia computerizzata delle metastasi renali calcificate enfatizzando le problematiche diagnostico differenziali. Sono state valutate retrospettivamente le indagini TC addominali di 8000 pazienti affetti da tumore nel periodo 1984-1998, analizzando le lesioni calcificate riscontrate.

2000-03-01

487

CHARACTERIZATION OF DEXTRIN PREPARED BY COMMON NEUTRAL AND THERMOSTABLE a-AMYLASES  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT With corn starch as raw material, dextrin was prepared by the combined application of common neutral and thermostable a-amylases in this study. The effects of reaction temperature, reaction time, addition of common neutral and thermostable a-amylases on dextrose equivalent (DE)-value of dextrin were investigated. The obtained dextrin with a DE value of 20.43 was evaluated for morphology, crystallography, particle size distribution and thermal property by scanning electron microscope, X-ray diffractometer, light scattering particle size analyzer and thermogravimetric analyzer. The results showed that the amorphous regions in the core part of corn starch were completely hydrolyzed and only the fractured crystalline surface remained. The particle size of the dextrin change significan...

2010-01-01

488

Bulk amorphous and nanocrystalline Al83Fe17 alloys prepared by consolidation of mechanically alloyed amorphous powder  

British Library Electronic Table of Contents (United Kingdom)

In the present work, bulk amorphous and nanocrystalline Al83Fe17 alloys were obtained by consolidation of mechanically alloyed powders. Mechanical alloying of Al-17% Fe powder mixture yielded powder with an amorphous structure. Thermal behaviour of the milling product was examined using differential scanning calorimetry. This investigation revealed that the amorphous phase crystallised above 380^oC. The amorphous powder was compacted under a pressure of 7.7GPa in different conditions: at 380^oC for 600s and at 1000^oC for 180s. Structural investigations of the bulk material revealed that the amorphous structure was retained after consolidation process applied at 380^oC. Compaction under high pressure at 1000^oC caused crystallisation of the amorphous phase and appearance of metastable nano...

2010-01-01

489

Biosorption of lead by citrobacter freundii immobilized on hazelnut shells  

Energy Technology Data Exchange (ETDEWEB)

Biosorption of lead from aqueous solutions by living and immobilized cell of C. freundii was examined as a function of metal concentration in a batch laboratory bioreactor. Lead concentrations were analyzed using Atomic Absorption Spectrophotometer (AAS). X-ray Energy Dispersion (EDX) analyses were made in order to determine the accumulation of lead on the cells and shell surfaces. Before and after the experiments the biomaterials and adsorbents were examined by Scanning Electron Microscopy (SEM). Biosorption was detected over a range of initial lead concentrations from 25{times}10{sup -3} to 200{times}10{sup -3} kg/m{sup 3}. 15 refs., 4 figs.

1996-12-31

490

Automated bead-positioning system for measuring impedances of R-F cavity modes  

Energy Technology Data Exchange (ETDEWEB)

We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.

1993-05-01

491

Assessing the effect of an antimicrobial wound dressing on biofilms  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT To date the effect of silver-containing wound dressings on biofilms, known to be present in chronic wounds, has not been determined or documented. In this current study, we aimed to determine the antimicrobial effect of a silver-containing dressing on biofilms grown in a chambered slide model. Before the addition of a wound dressing onto a 24-hour biofilm, composed of either Pseudomonas aeruginosa, Enterobacter cloacae, Staphylococcus aureus, or a mixed bacterial community, a fluorescent dye was applied. This enabled the viability of sessile bacteria to be monitored in real-time, using a rapid form of confocal laser scanning microscopy over a contact time period of 48 hours. By analyzing all the three-dimensional data generated from the confocal time-lapse sequences, 90% of all se...

2008-01-01

492

Anisotropy of the structure and mechanical properties of low-alloy tungsten  

Energy Technology Data Exchange (ETDEWEB)

The authors examine the relationship of the structure and mechanical properties of similar alloys of tungsten with rhenium produced by the powder metallurgy method by sintering powders. Since the alloys were deformed by rolling, we examine the effect of the resultant anisotropy of the structure on the properties of the metal in various directions. The tests were conducted on an alloy of tungsten with 2 wt.% rhenium and, for comparison purposes, an alloy of tungsten with additions of oxides of yttrium and hafnium. The mechanical properties of the alloys, i.e., strength, cracking resistance, cold shortness temperature, were determined in the bend test. Structural examination was carried out using an optical microscope, electron scanning microscopy, and the method of transmission electron microscopy.

1987-12-01

493

Analysis of the different slip systems activated by tension in a #alpha#/#beta# titanium alloy in relation with local crystallographic orientation  

International Nuclear Information System (INIS)

The gliding modes of a duplex Ti-6Al-4V titanium alloy were investigated through in situ (scanning electron microscopy) tensile tests. A method based on electron back-scattering diffraction (EBSD) measurements was used to identify activated slip systems. The approach applied to a large number of grains allowed a statistical analysis of the nature (basal, prismatic, pyramidal) and distribution of the slip systems according to the crystallographic texture. A discussion concerning the pertinence of Schmid's law to explain the occurrence and succession of slip events is then proposed. The domain in favor of each type of slip system is finally presented by using inverse pole figures mapped with Schmid's factor iso-curves.

2005-02-01

494

Airbags to Martian Landers: Analyses at Sandia National Laboratories  

Energy Technology Data Exchange (ETDEWEB)

A new direction for the national laboratories is to assist US business with research and development, primarily through cooperative research and development agreements (CRADAs). Technology transfer to the private sector has been very successful as over 200 CRADAs are in place at Sandia. Because of these cooperative efforts, technology has evolved into some new areas not commonly associated with the former mission of the national laboratories. An example of this is the analysis of fabric structures. Explicit analyses and expertise in constructing parachutes led to the development of a next generation automobile airbag; which led to the construction, testing, and analysis of the Jet Propulsion Laboratory Mars Environmental Survey Lander; and finally led to the development of CAD based custom garment designs using 3D scanned images of the human body. The structural analysis of these fabric structures is described as well as a more traditional example Sandia with the ...

1994-03-01

495

A novel graphene nanosheets coated stainless steel fiber for microwave assisted headspace solid phase microextraction of organochlorine pesticides in aqueous samples followed by gas chromatography with electron capture detection  

British Library Electronic Table of Contents (United Kingdom)

In this study, a novel graphene nanosheets (GNSs) coated solid phase microextraction (SPME) fiber was prepared by immobilizing microwave synthesized GNSs on a stainless steel wire. Microwave synthesized GNSs were verified by X-ray diffraction, field emission-scanning electron microscopy (FE-SEM) and transmission electron microscope (TEM). GNS-SPME fiber was characterized using FE-SEM and the results showed the GNS coating was homogeneous, porous, and highly adherent to the surface of the stainless steel fiber. The performance and feasibility of the GNS-SPME fiber was evaluated under one-step microwave assisted (MA) headspace (HS) SPME followed by gas chromatography with electron capture detection for five organochlorine pesticides (OCPs) in aqueous samples. Parameters influencing the extra...

2011-01-01

496

A novel electrochemical alkylation of aniline with methanol over Zn/Cu salts modified kaolin  

British Library Electronic Table of Contents (United Kingdom)

A novel liquid phase alkylation of aniline with methanol over Zn/Cu salts modified kaolin assisted with a pair of porous carbon electrode in slurry-bed reactor under constant current intensity, room temperature and atmospheric pressure was reported. The Zn/Cu salts modified kaolin catalysts were synthesized and characterized by infrared spectrometer (IR), powder X-ray diffraction (XRD) and scanning electron microscopy (SEM), which showed that the transition metals were completely supported on kaolins structure and formed a pored one. The effect parameters, such as initial pH, electrolysis time, metal ratio with kaolin and salts composition in this electrochemical catalytic system, were studied. The procedure was inspected by ultraviolet-visible spectrum (UV-vis), and the product distributi...

2008-01-01

497

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

498

3D investigations of plasma erosion craters using FIB/SEM dual-beam techniques  

Energy Technology Data Exchange (ETDEWEB)

Plasma erosion craters caused by electrical discharges on the surface of materials are important features of the erosion processes resulting in the degradation of electrodes. In the present work, electrical discharges were produced on a bi-metallic Ni/Cu multilayered surface. By means of dual beam techniques, coupling a focused ion beam (FIB) and a scanning electron microscope (SEM), not only the surface but also the sub-surface structure of the craters were investigated. Using the combination of SEM, FIB and STEM-EDX, a complete three-dimensional investigation of the craters were carried out. The analysis of the microstructure modifications as a function of depth enabled to determine the field of interaction between the plasma and the material. (orig.)

2006-09-15