ETB dosemeter, a passive integrating radon dosemeter combining activated charcoal and TLD
Energy Technology Data Exchange (ETDEWEB)
A passive integrating radon dosemeter is described. The radon dosemeter is based on radon adsorption on activated charcoal. By placing TLD crystals inside an open charcoal container, the beta radiation from radon daughters, produced by the decay of adsorbed radon, is detected continuously during the exposure time. After closing the container, radiation will still be detected by the TLD crystal. Calibration procedures are reported and the suitability of the dosemeter is discussed. The dosemeter proved to be suitable for measurements during periods from a few days to two weeks both in domestic and mine atmospheres.
1983-01-01
A new type active personal dosemeter with a solid state detector
International Nuclear Information System (INIS)
We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.
1988-04-01
Response of track-etch dosemeters to environmental radon
Energy Technology Data Exchange (ETDEWEB)
The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
1991-01-01
International Nuclear Information System (INIS)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
Real time neutron dosemeter response calculations
International Nuclear Information System (INIS)
The response of a real time neutron dosemeter using a thin LiF target sandwiched between tow parallel surface barrier semiconductor detectors is studied for different neutron distributions and different angles of incidence. Calculations of the response function defined for a simultaneous detection by the two detectors of the particles emitted when the reaction "6Li(n,t)#alpha# occurs in the target are fulfilled by geometrical considerations of the reaction kinematics and the differential cross section variations. Finally, the efficiency of the studied detection systems is analyzed for dosimetric uses. (author).
1996-04-01
Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)
Energy Technology Data Exchange (ETDEWEB)
Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).
1993-01-01
Environmental radiation measurements using TLD in and around AERE, Dhaka. Technical note
Energy Technology Data Exchange (ETDEWEB)
The external background radiation level in and around the Atomic Energy Research Establishment (AERE) in Dhaka has been measured. The measurements were performed using lithium fluoride (LiF) thermoluminescence dosemeters (TLD-100) at 32 locations, all one metre above the ground. The annual average dose rate measured in the AERE environs was 1.74+-0.23 mGy.y/sup -1/ in air, based on analysis of thermoluminescence dosemeter data collected from 1982 to 1984.
1986-01-01
Some tests on measuring methods for indoor radon using activated charcoal
Energy Technology Data Exchange (ETDEWEB)
Two methods for measuring indoor radon concentrations using activated charcoal have been tested. The first method is the well-known technique with direct gamma-measurements on the exposed canister after the sampling period. The other method uses a thermoluminescence dosemeter placed in the charcoal canister, giving an integrated value of the radon concentration.
1985-10-01
Radiation doses and somatic risk to patients during cardiac radiological procedures
International Nuclear Information System (INIS)
The radiation dose to a series of adult and paediatric patients undergoing cardiac catheterisations and adults having percutaneous transluminal coronary angioplasty has been measured/determined directly using lithium fluoride thermoluminescent dosemeters and indirectly using an air ionisation chamber which indicated exposure-area product. Somatic and genetic risks are estimated from the dosimetry results. It is suggested that the magnitude of the radiation hazard is negligible compared with other clinical hazards associated with these procedures. (author).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)
1999-05-01
International Nuclear Information System (INIS)
Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
Energy Technology Data Exchange (ETDEWEB)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-08-01
Organ doses to atomic bomb survivors during photofluorography, fluoroscopy and computer tomography
International Nuclear Information System (INIS)
Doses to the salivary glands, thyroid gland, breast, lung, stomach and colon during mass radiological gastric screening, mass radiographic chest screening, upper gastrointestinal series and computed tomography were determined by exposing a female human phantom to simulated radiological X-ray examinations as performed in community hospitals. The doses were measured using thermoluminescent dosemeters, and the results will be used to document organ doses received by participants in the Atomic Bomb Casualty Commission/Radiation Effects Research Foundation Adult Health Study. (Author).
1991-01-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
Energy Technology Data Exchange (ETDEWEB)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-08-01
Report of the IPSM working party on low- and medium-energy x-ray dosimetry
International Nuclear Information System (INIS)
New values of the factors required to convert the reading of a radiation dosemeter calibrated in terms of air kerma (or exposure) into absorbed dose to water for medium-energy x-radiation were given in a code of practice published by the International Atomic Energy Agency in 1987. These are not considered to possess sufficient support from other sources. It is therefore recommended that the F-factors given or codes of practice should continue to be used. Values of backscatter factors for low-energy x-radiation (below 140 kV) in Supplement 17 of the British Journal of Radiology appear to be inaccurate. New values based on Monte Carlo calculations, and supported by new experimental data, are given for use in radiotherapy. (author).
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.
1982-01-01
Energy Technology Data Exchange (ETDEWEB)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-08-01
International Nuclear Information System (INIS)
When evaluating the risks of oncogenesis and cancer mortality following exposure to the radiations of the atomic bombs (A-bombs), the medical X-ray doses received by the A-bomb survivors must also be estimated and considered. Using a human phantom, dosimetry was performed to estimate the X-ray doses received by A-bomb survivors during medical examinations at the Radiation Effects Foundation (RERF) as part of the long-term follow-up on the Adult Health Study (AHS). These examinations have been estimated to represent nearly 45% of the survivors' cumulative medical irradiation dose. Doses to the salivary glands, thyroid gland, lung, breast, stomach and colon were measured using thermoluminescent dosemeters. The results, which are reported here, will aid in estimating organ doses received by individual AHS participants. (Author).
1991-01-01
Measurement of radon daughter product burden by TLD dosemeters
International Nuclear Information System (INIS)
A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.
Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report
Energy Technology Data Exchange (ETDEWEB)
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
2003-04-08
Dose dependence of semiconductor material conductivity as a means of high fluence dosimetry
Energy Technology Data Exchange (ETDEWEB)
Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).
1996-12-31
International Nuclear Information System (INIS)
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
The high sensitivity of CaSO{sub 4}: Dy as a thermoluminescent material is a great advantage when dealing with low dose levels, as in diagnostic radiology procedures. However, these kinds of dosemeters present a high energy dependence that must be precisely determined in the energy range of interest. Dosimetric pellets of CaSO{sub 4}: Dy are produced at IPEN since the end of the 80 Th decade. These pellets are produced in three forms: conventional CaSO{sub 4}: Dy (50 mg); thin CaSO{sub 4}: Dy (20 mg) and CaSO{sub 4}: Dy + 10% C (20 mg). The main applications of these dosemeters are in personal and environmental dosimetry. In this study, CaSO{sub 4}: Dy pellets produced at IPEN were evaluated in diagnostic radiology standard beams. These qualities are based on the IEC 61267 standard, and they were established at an industrial X-ray system Pantak/Seifert, model ISOVOLT 160HS. Former studies evaluated CaSO{sub 4}: Dy of different origins in ...
2006-07-01
DEFF Research Database (Denmark)
Applicability of a model to estimate radiofrequency electromagnetic field (RF-EMF) strength in households from mobile phone base stations was evaluated with technical data of mobile phone base stations available from the German Net Agency, and dosimetric measurements, performed in an epidemiological study. Estimated exposure and exposure measured with dosemeters in 1322 participating households were compared. For that purpose, the upper 10th percentiles of both outcomes were defined as the 'higher exposed' groups. To assess the agreement of the defined 'higher' exposed groups, kappa coefficient, sensitivity and specificity were calculated. The present results show only a weak agreement of calculations and measurements (kappa values between -0.03 and 0.28, sensitivity between 7.1 and 34.6). Only in some of the sub-analyses, a higher agreement was found, e.g. when measured instead of interpolated geo-coordinates were used to calculate the distance between households ...
2008-01-01
Results of radon concentration measurements in some regions of Russia
Energy Technology Data Exchange (ETDEWEB)
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m{sup -3}){sup -1}. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for 6-10 days, mainly during the summer. ...
1996-01-01
Results of radon concentration measurements in some regions of Russia
International Nuclear Information System (INIS)
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m"-"3)"-"1. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for 6-10 days, mainly during the summer. The ...
Prevention of lung cancer by remediation of residential exposure to radon daughters
Energy Technology Data Exchange (ETDEWEB)
The United States Bonneville Power Administration (BPA), as part of an energy conservation programme in the states of Washington, Oregon, Idaho, Wyoming, and Montana, has collected over 36,000 residential radon concentration measurements. Data were collected between 1983 and 1989 with ambient {alpha} etched track dosemeters. Based on the linear risk coefficient from the BEIR IV report for lifetime lung cancer in smokers and non-smokers, numbers of lung cancer cases attributable to radon exposure were predicted. Numbers of baseline lung cancer cases and numbers of these that were preventable by remediation were also estimated. Remediation to 10 pCi.1{sup -1}, to 4 pCi.1{sup -1}, and to outdoor levels were considered. With vital statistics data, results were extrapolated to populations in the states represented by the BPA data. Costs of remediation were estimated. Results were evaluated in terms of cost per cancer saved and per cent reduction in fatal lung cancer ...
1991-01-01
Neutron capture therapy beam on the LVR-15 reactor
Energy Technology Data Exchange (ETDEWEB)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si[sup 6]Li). ...
1992-01-01
Neutron capture therapy beam on the LVR-15 reactor
International Nuclear Information System (INIS)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si"6Li). Thermoluminescence ...
1991-10-01
Mine dumps as a source of radon impact on buildings
Energy Technology Data Exchange (ETDEWEB)
More than 100 old mine dumps active mine tailing ponds and granite quarries were investigated in South-West Germany to evaluate their potential impact on the environment caused by natural radioactive materials and by toxic metals. Five mine sites were monitored for a longer period according to their radon impact on the environment. They showed seasonal variations greater than a factor of 5 at some places. The annual mean radon concentration over granitic soil was found to be about 44 Bq.m/sup -3/ while very near the dumps more than 370 Bq.m/sup -3/ were usual. Radium concentrations up to 185 Bq.kg/sup -1/ were found in certain types of abandoned mine dumps. Some of the waste rock piles investigated are in the immediate neighbourhood of buildings and some old mine establishments are now used as homes. In these dwellings passive time integrating radon dosemeters have been exposed for up to a three month period. The average radon concentrations in the buildings ...
1984-01-01
Energy Technology Data Exchange (ETDEWEB)
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)
1999-07-01