A Virtual Young's Double Slit Experiment for Hard X-ray Photons
We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.
2009-01-01
New Radiation Stable and Long-Lived Plastic Scintillators
International Nuclear Information System (INIS)
A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiation hardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiation hardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is shown that one of the main reasons for aging ...
1993-11-15
Radiation hardness of plastic scintillating fiber
International Nuclear Information System (INIS)
We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).
... 89 11 August 195Z SCINTILLATION COUNTERS *Subtask uder Effects of Irradiation, AMRL Project No. ... 89 SCINTILLATION COUNTERS* by ...
1952-08-11
Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation
International Nuclear Information System (INIS)
In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light transmittance of the ...
1992-10-25
Photodiode Scintillation Detector for Anti-Coincidence Shielding
Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...
Distribution Models for Optical Scintillation Due to ...
... Lincoln Laboratory Distribution Models for Optical Scintillation Due to Atmospheric Turbulence RR Parenti RJ Susiela Group 107 ...
2005-12-12
Comparative Equatorial Scintillation Morphology--American ...
... Accession Number : ADA066094. Title : Comparative Equatorial Scintillation Morphology--American and Pacific Sectors. ...
1978-06-30
Recent advance of focused ion beam technology in maskless deposition and patterning
International Nuclear Information System (INIS)
The present article will review recent advances in focused ion beam (FIB) technology. With increasing demands for scale of integration, microfabrication technology is becoming more important and various new microfabrication tools and processing techniques are desired. FIB is one of the promising tools for future microfabrication technology. This provides maskless patterning capability, which is of importance for process simplification, nanofabrication and in the development of in situ vacuum processing. In situ vacuum processing systems are being developed by combining FIB and a molecular beam epitaxy system. Radiation damage may limit applications of FIB. However, it was demonstrated that low energy FIB (<1 keV) with very high brightness was reached and promising results for low damage processing have been obtained. (orig.).
Contact Line Pinning by Microfabricated Patterns: Effects of Microscale Topography
UK PubMed Central (United Kingdom)
We study how the microscale topography of a solid surface affects the apparent advancing and receding angles at the contact line of a liquid drop pinned to this surface. Photolithographic methods...Full Text Available
2009-05-05
Atmospheric Scintillation Effects on Electromagnetic Weapons
... 4. TITLE AND SUBTITLE Atmospheric Scintillation Effects on Electromagnetic Weapons 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. ...
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in ...
1998-01-01
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of polarized ...
2005-01-01
Presentation of random process at the output of a scintillation detector
International Nuclear Information System (INIS)
(1973). USSR Ovcharenko, AM Nedavnij, OI Kapranov, BI Tomskij
Scintillation Velocity of PSR B0329+54
We monitored PSR B0329+54 for one year using the Nanshan 25-m radio telescope, the scintillation velocity V ISS shows evidence of systematic variation with the day of the year. States of interstellar medium (ISM) are discussed.
2011-07-01
Study on the forming of images of an object internal structure in a scintillation crystal
International Nuclear Information System (INIS)
1975. USSR Zabrodskij, VA Nedavnij, OI INIS-mf--3677. Available from
1975-09-03
Scintillation converter screen investigation for real-time neutron radiography
International Nuclear Information System (INIS)
(1980). United States Panhuise, VE Bull, SR Seydel, JA Univ of Missouri-
1980-11-21
Performance optimization of the Packard 2000 CA/LL liquid scintillation counter for "1"4C dating
International Nuclear Information System (INIS)
The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).
International Nuclear Information System (INIS)
Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.
International Nuclear Information System (INIS)
This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ideal ...
2007-04-07
International Nuclear Information System (INIS)
Tritium occurs in nature in trace amounts, but its concentration is changing due to natural and artificial sources. Studies focusing on natural tritium have to take into account the effect of artificial sources. Also, the impact of tritium is an important issue in environmental protection, e.g. in connection with the emissions from nuclear power plants. The present work focuses on the rain washout of tritium emitted from the Paks nuclear power plant in Hungary. Rainwater collectors were placed around the plant and after a period of precipitation, rainwater was collected and analysed for tritium content. Samples were analysed using low-level liquid scintillation counting, with some also subject to the more accurate "3He ingrowth method. The results clearly show the trace of the tritium plume emitted from the plant; however, values are only about one order of magnitude higher than environmental background levels. A washout model was devised to estimate the ...
2011-01-01
Microfabrication processes for high-T_c superconducting films
International Nuclear Information System (INIS)
Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-T_c superconducting lines as narrow as 0.8 #mu#m have been fabricated from epitaxial YBa_2Cu_3O_7 _- _y films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 #mu#m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 x 10"4 A/cm"2 at 77.3 K. Maskless etching was carried out using 130-keV au"+ focused ion-beam (FIB) with a 0.1-#mu#m-diameter beam. A 50-nm-thick film was patterned into 0.3-#mu#m-wide lines at a dose of 5 x "1"6 ions/cm"2. In comparison with Ar IBE, Cl_2 reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si"+ "+ FIB also indicated the possibility to produce submicrometer patterns by selectively modifying film properties from superconductive to normal or insulting.
Measurement of liquid xenon scintillation from heavy ions using a silicon photodiode
Energy Technology Data Exchange (ETDEWEB)
Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).
1991-11-15
Computer model of high-latitude scintillation. [WBMOD program
Energy Technology Data Exchange (ETDEWEB)
The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.
1982-01-01
Computer model of high-latitude scintillation
International Nuclear Information System (INIS)
The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.
Impact of Ionospheric Scintillations on Space-Based ...
... Zinn, J., Hoerlin, H., and Petschek, AG, "The Motion of Bomb Debris Follow- ing the Starfish Test," Radiation Trapped in the Earth's Magnetic Field ...
1991-06-01
The Effect of Cocktail on Radiocarbon Analysis by Direct Absorption of Carbon dioxide
International Nuclear Information System (INIS)
Carbon-14 was analysed by direct absorption of carbon dioxide on the mixture of organic amine compound and scintillation cocktail then counted by low level liquid scintillation counter. This method can be applied for radiocarbon dating. In this study, the effects of carbon dioxide absorption, and counting efficiency were investigated using various commercial available cocktail. It was found that permafluor V and Ready Gel showed the highest carbon dioxide absorption whereas the Permafluor V showed the highest counting efficiency
1998-12-01
Aqueous liquid scintillation counting with fluor-containing nanosuspensions
Energy Technology Data Exchange (ETDEWEB)
A microemulsion comprised of water, Brij 78, pentanol and styrene into which PPO and bis-MSB had been dissolved was prepared. Polymerization of the styrene resulted in a suspension of fluor-containing polystyrene nanoparticles (<100 nm). After a concentration step, the aqueous nanosuspension was able to detect {sup 14}C with counting efficiencies over 50% of those of a commercially available scintillation cocktail. Monte Carlo calculations demonstrated that the size and concentration of the nanoparticles were appropriate for optimum detection efficiency.
2004-06-01
Hard Corrosion and Radiation-Resistant Coatings
International Science & Technology Center (ISTC)
Hard Nano-Strutural Coatings Resistant to the Extreme Conditions of Chemical, Abrasive and High Energy Media for Thermonuclear Power, Oil and Gas and Chemical Industries
FATIGUE OF BIOMATERIALS: HARD TISSUES
UK PubMed Central (United Kingdom)
The fatigue and fracture behavior of hard tissues are topics of considerable interest today. This special group of organic materials comprises the highly mineralized and load-bearing tissues...Full Text Available
2010-09-01
Mid-latitude scintillation model. Technical report, 1 November 1985-31 October 1986
Energy Technology Data Exchange (ETDEWEB)
Radiowave scintillation in the presence of ionospheric disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report describes development of a model characterizing the plasma density irregularities that produce scintillation in the naturally disturbed mid-latitude F layer. The model will be incorporated into Program WBMOD, which includes subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. Earlier versions of WBMOD, were based on extensive analysis of scintillation data collected in the auroral and equatorial zones in Wideband Satellite Mission. The model described herein is based on similarly extensive analysis of Wideband data from one mid latitude station and of data collected from HiLat satellite at another mid latitude station. The model describes irregularities at an effective ...
1986-10-31
International Nuclear Information System (INIS)
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to ...
2007-08-21
International Nuclear Information System (INIS)
Lithium carbonate pellets are frequently used for estimation of tritium production rate in irradiated samples in fusion blanket neutronics experiment and the activity is measured by liquid scintillation counting technique. In this measurement, it is essential to solve the lithium carbonate pellet as much as possible and to mix the pellet solution into scintillation cocktail homogeneously at stable condition. For this purpose, a novel binary-acid method has been developed to solve lithium carbonate and to mix the pellet solution into scintillation cocktail. High solubility is attained by adopting two acids, HNO_3 and CH_3COOH, and a good compatibility of the pellet solution with scintillator is obtained by emulsion cocktail resulting in high counting efficiency. Defining a product of dissolved mass and counting efficiency as a Figure of Merit (FOM), the present method has higher FOM value than the ...
Micro-patterning of chemical functionality of anthracene-bis-resorcinol film using focused ion beam
International Nuclear Information System (INIS)
Anthracene-bis-resorcinol is an interesting molecule as it forms a hydrogen-bonded network when guest molecules with weak polarity are included. Focused ion beam (FIB) was irradiated on a part of its amorphous film with low dose, and the film was exposed to the vapor of guest molecules. From fluorescence and AFM analyses of this film, it was found that no inclusion compound was formed in FIB irradiated area, i.e. FIB irradiation suppresses the ability to form the inclusion compounds. By utilizing this phenomenon, we succeeded in a microfabrication of relief structures consisting of inclusion compounds which has different fluorescence from its surrounding. Morphology, fluorescence, and IR absorption analyses indicated that hydroxyl or resorcin groups are damaged by ion beams, and consequently a formation of hydrogen-bonded networks, which play a role of a lattice caging guest molecules, becomes impossible.
2005-12-15
Autonomous multi-sensor micro-system for measurement of ocean water salinity
British Library Electronic Table of Contents (United Kingdom)
This paper describes the design, fabrication and application of a micro-fabricated salinity sensor system. The theoretical electrochemical behaviour is described using electrical equivalent diagrams and simple scaling properties are investigated analytically and numerically using finite element method (FEM). The chip design and fabrication is described and measurement results of two different electrode designs are presented. The 4mm Formula Not Shown 4mm multi-sensor allows for salinity determination with an accuracy of Formula Not Shown 0.5psu through determination of the electrical conductivity, temperature and pressure with accuracies of Formula Not Shown 0.6mS, Formula Not Shown 0.065 Formula Not Shown C and Formula Not Shown 0.05bar, respectively.
2008-01-01
A microscopic model of electronic field noise heating in ion traps
Motional heating of ions in micro-fabricated traps is a challenge hindering experimental realization of large-scale quantum processing devices. Recently a series of measurements of the heating rates in surface-electrode ion traps characterized their frequency, distance, and temperature dependencies, but our understanding of the microscopic origin of this noise is still vague. In this work we develop a theoretical model for the electric field noise which is associated with a random distribution of adsorbed atoms on the trap electrode surface. By using first principle calculations of the fluctuating dipole moments of the adsorbed atoms we evaluate the distance, frequency and temperature dependence of the resulting electric field fluctuation spectrum.Our theory calculates the noise spectrum beyond the standard scenario of two-level fluctuators, by incorporating all the relevant vibrational states. The $1/f$ noise is shown to commence at roughly the frequency of the ...
2011-01-01
Development of Novel Polycrystalline Ceramic Scintillators
Energy Technology Data Exchange (ETDEWEB)
For several decades most of the efforts to develop new scintillator materials have concentrated on high-light-yield inorganic single-crystals while polycrystalline ceramic scintillators, since their inception in the early 1980 s, have received relatively little attention. Nevertheless, transparent ceramics offer a promising approach to the fabrication of relatively inexpensive scintillators via a simple mechanical compaction and annealing process that eliminates single-crystal growth. Until recently, commonly accepted concepts restricted the polycrystalline ceramic approach to materials exhibiting a cubic crystal structure. Here, we report our results on the development of two novel ceramic scintillators based on the non-cubic crystalline materials: Lu SiO:Ce (LSO:Ce) and LaBr:Ce. While no evidence for texturing has been found in their ceramic microstructures, our LSO:Ce ceramics exhibit a surprisingly ...
2008-06-01
Energy Technology Data Exchange (ETDEWEB)
An analysis was perfonned on the mid-latitude scintillation and coherence frequency bandwidth (Fcoh) using transionospheric VHF signal data. The data include 1062 events spanning from November 1997 to June 2002. Each event records FORTE satellite received VHF signals from LAPP located at Los Alamos, New Mexico. Fcohs were derived to study scintillation characteristics on diurnal and seasonal variations, as well as changes due to solar and geomagnetic activities. Comparisons to the VHFIUHF coherence frequency bandwidth studies previously reported at equatorial and mid-latitude regions are made using a 4th power frequency dependence relationship. Furthennore, a wideband ionospheric scintillation model, WBMOD, was used to estimate Fcohs and compared with our VHF Fcoh values. Our analysis indicates mid-latitude scintillation characteristics that are not previously revealed. At the VHF bottom frequency range ...
2008-01-01
International Nuclear Information System (INIS)
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
1996-01-01
Large scintillation cells for high sensitivity radon concentration measurements
Energy Technology Data Exchange (ETDEWEB)
Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alpha source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from ...
1983-07-01
Large scintillation cells for high sensitivity radon concentration measurements
International Nuclear Information System (INIS)
Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alphy source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from ...
Development of a small scintillation detector with an optical fiber for fast neutrons
International Nuclear Information System (INIS)
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained experimentally.
2011-02-01
Microfabrication processes for high-T sub c superconducting films
Energy Technology Data Exchange (ETDEWEB)
Microfabrication processes for Y-Ba-Cu-O films have been investigated, using ion-beam techniques. High-{Tc} superconducting lines as narrow as 0.8 {mu}m have been fabricated from epitaxial YBa{sub 2}Cu{sub 3}O{sub 7 {minus} {ital y}} films by Ar ion-beam etching (IBE), combined with focused ion-beam (FIB) lithography. The resulting lines, 1.3 {mu}m wide and 2 mm long, showed a zero resistance temperature of 81 K and a critical current density of 1.9 {times} 10{sup 4} A/cm{sup 2} at 77.3 K. Maskless etching was carried out using 130-keV au{sup +} focused ion-beam (FIB) with a 0.1-{mu}m-diameter beam. A 50-nm-thick film was patterned into 0.3-{mu}m-wide lines at a dose of 5 {times} {sup 16} ions/cm{sup 2}. In comparison with Ar IBE, Cl{sub 2} reactive ion-beam etching (RIBE) exhibited an enhancement effect in sputtering yield. Ion implantation with 300-keV Si{sup + +} FIB also indicated the possibility to produce submicrometer patterns by selectively modifying film ...
1989-12-01
Energy Technology Data Exchange (ETDEWEB)
A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, ...
1999-07-01
Scintillation proximity assay for measurement of RNA methylation
UK PubMed Central (United Kingdom)
Methylation of RNA by methyltransferases is a phylogenetically ubiquitous post-transcriptional modification that occurs most extensively in transfer RNA (tRNA) and ribosomal RNA (rRNA). Biochemical...Full Text Available
2009-03-01
International Nuclear Information System (INIS)
Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight exposure. (orig.).
Measurement of cosmic ray neutron spectrum at sea level
International Nuclear Information System (INIS)
The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).
Synthesis and scintillation properties of GdCl_3:Ce"3"+ (Gd_1_-_xCe_xCl_3_,x = 0.005-0.08)
International Nuclear Information System (INIS)
Single crystals of GdCl_3 doped with different concentrations of Ce"3"+ have been grown using the Bridgman-Stockbarger technique and their luminescence and scintillation properties were investigated. The luminescence spectrum of GdCl_3:Ce"3"+ is complex and consists of two bands with maxima at 350 nm and 370 nm. The maximal light yield in GdCl_3:Ce"3"+ was observed at #approx#1 mol% of Ce"3"+ (more than 38 000 ph/MeV).
2009-07-08
LUCIFER, a potentially background-free approach to the search for neutrinoless double beta decay
British Library Electronic Table of Contents (United Kingdom)
LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.
2011-01-01
A high-sensitivity scintillation chamber for radon in gas
Energy Technology Data Exchange (ETDEWEB)
A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))
1994-06-15
UK PubMed Central (United Kingdom)
BackgroundThe hard clam, Mercenaria mercenaria, has been affected by severe mortality episodes associated with the protistan parasite QPX (Quahog Parasite Unknown)...Full Text Available
Hardness, density, and shrinkage characteristics of silk-oak from ...
Sep 1, 2011 ... Title: Hardness, density, and shrinkage characteristics of silk-oak from Hawaii. Author: Youngs, R. L.. Date: 1964. Source: Research note FPL ...
Beam-induced damage on diffractive hard X-ray optics
UK PubMed Central (United Kingdom)
The issue of beam-induced damage on diffractive hard X-ray optics is addressed. For this purpose a systematic study on the radiation damage induced by a high-power X-ray beam is carried out in both...Full Text Available
2010-11-01
AC-130H Gunship Armor Upgrade Project
Energy Technology Data Exchange (ETDEWEB)
This report covers the test methods and equipment for testing aircraft armor both hard and soft. The hard armor are the typical ceramic type while the soft armor are various types of layered composite materials. 10 figs. (JEF)
1990-09-19
Simple transistor neutron hardness screen using scattering parameters
International Nuclear Information System (INIS)
(Dec 1973). United States Tausch, HJ Antinone, RJ Bailey, RA Air Force
Equatorial scintillation model. Technical report, 1 February 1983-30 April 1985
Energy Technology Data Exchange (ETDEWEB)
Radiowave scintillation in the presence of natural and/or high-altitude nuclear disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report develops a model characterizing the plasma-density irregularities that produce scintillation in the naturally disturbed equatorial F layer. The model is incorporated into Program WBMOD along with subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. The model is based on similarly extensive analysis of wideband data from two equatorial stations. It describes irregularities at an effective height of 350 km that are isotropic across the geomagnetic field and elongated by a factor of 50 along the field and whose one-dimensional spatial power spectrum obeys a single-regime power law with a (negative) spectral index of 1.5. The height-integrated spectral strength of the ...
1985-09-30
Energy Technology Data Exchange (ETDEWEB)
Permalloy (Ni{sub 80}Fe{sub 20})/Cu multilayered nanowires (NWs) were electrodeposited using a template directed method from sulfate baths via pulse potential technique. Microstructures and compositions of the nanowires were characterized using various microscopy and spectroscopy techniques. To synthesize compositionally uniform nanowires with high efficiency, new sulfate baths with a high content of Ni{sup 2+} were developed. The effects of deposition potential and concentration of metal ions were optimized to reduce composition inhomogeneity and incorporation of copper in the permalloy layers. Composition of the NiFe layers was found to be close to 20 at% Fe with a maximum of 5 at% Cu. TEM analysis indicated that individual nanowires exhibit distinct and coherent layering structure with rough and wavy interfaces. A synthesized single nanowire was also AC dielectrophoretically assembled across the microfabricated gold electrodes for subsequent magnetoresistance ...
2010-12-15
Long-life bismuth liquid metal ion source for focussed ion beam micromachining application
International Nuclear Information System (INIS)
Liquid metal ion sources (LMISs) with Ga as ion species are widely used in focused ion beam (FIB) technology for micromachining and surface treatment on the sub-micron and nano-scale. Key features of a LMIS for investigating mechanical properties and 3D-microfabrication of materials are long life-time, high brightness, stable ion current and a highly effective milling ability for the material to be modified. In order to increase the material removal rate, heavier ions than Ga and their clusters should be applied. Bismuth (Bi) is the heaviest, non-radio-active element in the periodic table, is non-toxic and exhibits a low melting point. We have thus produced a long-life (about 1000 h) Bi LMIS with a good beam performance, applicable in any FIB system. Since Bi is the only element in this source, it is not necessary to separate it from other ions by a mass filter. Investigation of the sputtering rate of NiTi shape memory alloys using Ga and Bi LMIS showed that, for ...
2008-09-15
Focused ion beam techniques for fabricating geometrically-complex components and devices.
Energy Technology Data Exchange (ETDEWEB)
We have researched several new focused ion beam (FIB) micro-fabrication techniques that offer control of feature shape and the ability to accurately define features onto nonplanar substrates. These FIB-based processes are considered useful for prototyping, reverse engineering, and small-lot manufacturing. Ion beam-based techniques have been developed for defining features in miniature, nonplanar substrates. We demonstrate helices in cylindrical substrates having diameters from 100 {micro}m to 3 mm. Ion beam lathe processes sputter-define 10-{micro}m wide features in cylindrical substrates and tubes. For larger substrates, we combine focused ion beam milling with ultra-precision lathe turning techniques to accurately define 25-100 {micro}m features over many meters of path length. In several cases, we combine the feature defining capability of focused ion beam bombardment with additive techniques such as evaporation, sputter deposition and electroplating in order to ...
2004-03-01
Energy Technology Data Exchange (ETDEWEB)
A new method is being developed to quickly screen for the human exposure potential to polycyclic aromatic hydrocarbons (PAHs) and organochlorines (OCs). The development involves two key elements: identifying suitable signals that represent intracellular changes that are specific to PAH and OC exposure, and constructing a device to guide the biological cell growth so that signals from individual cells are consistent and reproducible. We are completing the identification of suitable signals by using synchrotron radiation-based (SR) Fourier-transform infrared (FTIR) spectromicroscopy in the mid-infrared region (4000-400 cm-1). Distinct changes have been observed in the IR spectra after treatment of human cells in culture medium with PAHs and OCs. The potential use of this method for detecting exposure to PAHs and OCs has been tested and compared to a reverse transcription polymerase chain reaction (RT-PCR) assay that quantifies increased expression of the CYP1A1 gene in response to exposu ...
1999-01-10
An accurate high-speed single-electron quantum dot pump
International Nuclear Information System (INIS)
Using standard microfabrication techniques, it is now possible to construct devices that appear to reliably manipulate electrons one at a time. These devices have potential use as building blocks in quantum computing devices, or as a standard of electrical current derived only from a frequency and the fundamental charge. To date, the error rate in semiconductor 'tuneable-barrier' pump devices, those which show most promise for high-frequency operation, have not been tested in detail. We present high-accuracy measurements of the current from an etched GaAs quantum dot pump, operated at zero source-drain bias voltage with a single ac-modulated gate at 340 MHz driving the pump cycle. By comparison with a reference current derived from primary standards, we show that the electron transfer accuracy is better than 15 parts per million. High-resolution studies of the dependence of the pump current on the quantum dot tuning parameters also reveal possible deviations from a ...
2010-07-01
Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear correlation of 0.997 of ...
2002-06-01
International Nuclear Information System (INIS)
The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of LAAPDs in energy spectrometry with ...
1998-06-01
Atmospheric scintillations and laser safety
Laser devices are currently in widespread use in particular by armed forces for different tasks. Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser damage depends on the interaction between the laser beam and the atmosphere in which it traverses. The atmospheric conditions, including the range, terrain features, turbulence, and atmospheric particulates, may alter the laser's effect on different electro-optical devices and systems. When a laser beam passes through the atmosphere the optical turbulence affects the beam. As a result, temporal intensity fluctuations (scintillations) or spatial variations in intensity within a beam cross-section occur. Atmospheric scintillations pose a safety problem because an observer or sensor can be subjected to the risk of a localized irradiance (local focusing effect) much greater than that ...
2011-09-01
Energy Technology Data Exchange (ETDEWEB)
Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth's ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can be used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the second year, which include completion of the new models for the equatorial region and initial development of models for the high latitude (auroral and polar cap) region.
1993-11-01
Energy Technology Data Exchange (ETDEWEB)
Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth`s ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can he used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the third year of this project, which includes completion of the new model for the high-latitude (auroral and polar cap) region of the WBMOD model.
1994-08-31
Development of a new #gamma#-ray detector for PEM applications
International Nuclear Information System (INIS)
The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)
2007-05-01
Energy Technology Data Exchange (ETDEWEB)
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeV electrons trapped in a coronal loop or ...
1988-01-01
The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.
1986-05-01
Searches for Fast Radio Transients
We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.
2003-01-01
Search for tachyons associated with extensive air showers in the ground level cosmic radiation
International Nuclear Information System (INIS)
Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.
1985-08-01
Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy
International Nuclear Information System (INIS)
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
International Nuclear Information System (INIS)
Research and development activities are reported on absorption spectroscopy, calorimetry, electrolysis, emission spectroscopy, fluorimetry gas chromatography, infrared spectroscopy, liquid chromatography, liquid scintillation counting, mass spectroscopy, microscopy, radiometric analysis, and thermal analysis. A group of miscellaneous projects are also described.
Phantom simulation device for scintillation cameras
Energy Technology Data Exchange (ETDEWEB)
A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.
1981-08-25
International Nuclear Information System (INIS)
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
1980-01-01
New crystals for dual-readout calorimetry
Lead tungstate crystals doped with small fractions of praesodynium or molybdenum have been tested in beams of high-energy electrons. The goal of these tests was to study the effects of such dopants on the capability to separate the signal components deriving from the Cherenkov and scintillation light generated by the beam particles. These studies were carried out in view of the possible application of such crystals in dual-readout calorimeters.
2009-01-01
Medical explorations by radioisotopes in Lebanon
International Nuclear Information System (INIS)
This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.
Measurement of the oil consumption of compressors
International Nuclear Information System (INIS)
This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).
Bragg curve spectroscopy in a 4? geometry
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.
1991-02-01
Bragg curve spectroscopy in a 4. pi. geometry
Energy Technology Data Exchange (ETDEWEB)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
1991-02-01
Bragg curve spectroscopy in a 4#pi# geometry
International Nuclear Information System (INIS)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
A search for tachyons in extensive air showers
International Nuclear Information System (INIS)
A search for tachyons, or other particles detectable by G-M counter tubes or liquid scintillators, arriving during the approximately 100#mu#s immediately preceding extensive air showers (primary energy approximately 10"1"5 eV) has provided no positive evidence for the existence of such particles. (orig.).
A search for tachyons in cosmic ray showers
International Nuclear Information System (INIS)
A search has been made of tachyons associated with cosmic ray showers of energies about 10"1"5 eV by searching for any precursor effects observed in plastic scintillator detectors. Detection thresholds well below most other similar experiments have been reached but no statistically significant effects have been found.
Theoretical considerations for SRAM total-dose hardening
International Nuclear Information System (INIS)
The theoretical hardness against total dose of the six-transistor SRAM cell is investigated in detail. An explicit analytical expression of the maximum tolerable threshold voltage shift is derived for two cross-coupled inverters. A numerical method is used to explore the hardness of the read and write operations. Both N- and P-channel access transistors designs are considered and their respective advantages are compared. The study points out that the radiation hardness mainly relies on the technology. Results obtained with the very robust Gate-All-Around process are finally presented.
Replacement of bearing journals on heat transport pumps at the Wolsung nuclear generating station
International Nuclear Information System (INIS)
The major details of the inspection and replacement of the bearing journals on each of the four heat transport pumps (HTPs) at Wolsung nuclear generating station in Korea are presented in this paper. Investigation following fracture of one of the journals in 1985 revealed that it was excessively hard. The journal material (ASTM A296 CA 40) is considered to be prone to stress corrosion fatigue if the hardness exceeds Rc 40. In 1986 May, during a planned outage, the HTPs were disassembled, the journals were inspected, found to be excessively hard, and all were replaced. At the same time, the pump to motor couplings were all refurbished to ensure proper alignment.
1987-11-22
Generation of microwaves and hard X-rays in a flash X-ray tube
Energy Technology Data Exchange (ETDEWEB)
High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.
1982-01-01
Fabrication of beta-sialon having high hardness
International Nuclear Information System (INIS)
Hardness of beta-sialon with four different composition index values of 0.25, 0.50, 0.75 and 1.0 in the system Ni/sub 3/N/sub 4/-AlN-Al/sub 2/O/sub 3/ with the addition of 6% Y/sub 2/O/sub 3/ as sintering aid has been reported. These composition were pressureless sintered for 90, 180 and 270 min in nitrogen atmospheres at temperatures ranging from 1650 to 1800 deg. C. Highest hardness was achieved when the composition index was 0.25 was sintered for 270 minutes at 1750 deg. C. (author).
An Apparent Hard X-ray Decline of CH Cygni
CH Cygni is a symbiotic star consisting of an M giant and an accreting white dwarf, which is known to be a highly variable X-ray source with a complex, two-component, spectra. Here we report on two Suzaku observations of CH Cyg, taken in 2006 January and May, during which the system was seen to be in a soft X-ray bright, hard X-ray faint state. Based on the extraordinary strength of the 6.4 keV fluorescent Fe K-alpha line, we show that the hard X-rays observed with Suzaku are dominated by scattering.
2006-01-01
What Makes Some Problems Really Hard: Explorations in the ...
... of Hanoi or Missionaries and Cannibals, It is not immediately obvious what constitutes a "move"--that is, what actual manipulations of the physical ...
1988-09-01
International Nuclear Information System (INIS)
... base alloys alloys beams chemical reactions elements hardness irradiation
2010-09-06
International Nuclear Information System (INIS)
Monolithic SiAlON ceramics are hard and brittle with little possibility for property design, but multi-phase SiAlON ceramics offer great scope for controlling microstructural development and desired properties. The ceramics can also be reinforced by separate additions of other hard, refractory compounds. The toughness in all these SiAlON composites can be increased by several mechanisms, and the best effect is reached if they are combined. When glassy phase is present, crack paths are affected by the strains caused by different thermal expansion of the glassy phase and the crystals and also by the interface properties. The crystal shape influence toughness, especially pronounced is the effect of the elongated #beta#- grains. Different toughening mechanisms are achieved by separately added reinforcement phases. The hardness is raised by the presence of #alpha# SiAlON and other hard constituents, such as ...
1993-10-04
Energy Technology Data Exchange (ETDEWEB)
Counter-current regeneration of 2-stage sodium zeolite softeners has been employed in reducing hardness leakage level of steamflooding water to less than 1 ppm when raw water contains as much as 5,000 ppm of the total dissolved solids. Hardness leakage is caused by sodium displacement of calcium and magnesium from the bottom of the exchanger bed. This study presents nomographs providing for rapid calculations to be made, for which a convenient operational mode does not already exist. The nomographs relate the hardness leakage as a function of salt quality and influent water quality and present solutions for predicting the leakage level, salt quality requirement or the treatability of raw water required for steamflooding projects.
1982-08-01
New Frontiers in Binary Stars: Science at High Angular ...
... interacting systems in which common-envelope evolutionary effects make it hard to generalize the results to single-star evolution, although they ...
2011-05-15
Neurocysticercosis, a Persisting Health Problem in Mexico
UK PubMed Central (United Kingdom)
BackgroundThe ongoing epidemiological transition in Mexico minimizes the relative impact of neurocysticercosis (NC) on public health. However, hard data on the disease frequency...Full Text Available
Necrotizing sialometaplasia of tongue
UK PubMed Central (United Kingdom)
Necrotizing sialometaplasia, is a benign inflammatory lesion primarily involving the minor salivary glands of the hard palate. The lesion often presents itself as a deep-seated palatal ulcer with clinical...Full Text Available
2009-01-01
NASA - Top Dog K-9 Unit Keeps Kennedy Safe
Oct 30, 2009... of Belgian sheepherding dogs that are popular with the police and military. ... "She was a hard-working K-9 and she will be missed." ...
International Nuclear Information System (INIS)
Turkish English ... Authors Sahin, O. (Suleyman Demirel University, Department of Physics, Isparta (Turkey))
2007-08-28
Broad-band hard X-ray reflectors
DEFF Research Database (Denmark)
Interest in optics for hard X-ray broad-band application is growing. In this paper, we compare the hard X-ray (20-100 keV) reflectivity obtained with an energy-dispersive reflectometer, of a standard commercial gold thin-film with that of a 600 bilayer W/Si X-ray supermirror. The reflectivity of the multilayer is found to agree extraordinarily well with theory (assuming an interface roughness of 4.5 Angstrom), while the agreement for the gold film is less, The overall performance of the supermirror is superior to that of gold, extending the band of reflection at least a factor of 2.8 beyond that of the gold, Various other design options are discussed, and we conclude that continued interest in the X-ray supermirror for broad-band hard X-ray applications is warranted.
1997-01-01
Results for the structural properties of random heaps of hard disks
Energy Technology Data Exchange (ETDEWEB)
The average angle of repose and the packing density of random planar heaps of hard disks falling ballistically onto a sticky base line, where the first layer of disks is quenched in random positions, are computed for heaps with a small fixed number of gaps in the base layer. The results we find appear to be almost independent of the size of the heap and they agree with those obtained from computer simulations of large systems.
1995-01-01
Electron-beam cladding of wear-resistant composite coatings on the base of titanium carbide
International Nuclear Information System (INIS)
The structure and properties of composite powder coatings on the base of titanium carbide are studied. It is shown the electron-beam welding deposition of powders on the base of nickel and titanium carbide allows to produce of high-quality wear-resistant coatings which superior in density and hardness compared with sputtered ones. Changes of hardening phase volume percentage as well as composition of metal matrix make possible to control coatings hardness
Variability and spectral modeling of the hard X-ray emission of GX 339-4 in a bright low/hard state
We study the high-energy emission of the Galactic black hole candidate GX 339-4 using INTEGRAL/SPI and simultaneous RXTE/PCA data. By the end of January 2007, when it reached its peak luminosity in hard X-rays, the source was in a bright hard state. The SPI data from this period show a good signal to noise ratio, allowing a detailed study of the spectral energy distribution up to several hundred keV. As a main result, we report on the detection of a variable hard spectral feature (>150 keV) which represents a significant excess with respect to the cutoff power law shape of the spectrum. The SPI data suggest that the intensity of this feature is positively correlated with the 25 - 50 keV luminosity of the source and the associated variability time scale is shorter than 7 hours. The simultaneous PCA data, however, show no significant change in the spectral shape, indicating that the source is not undergoing a canonical ...
2010-01-01
The Hard X-ray Spectral Evolution in XRBs, AGNs and ULXs
We explore the relationship between the hard X-ray photon index $\\Gamma$ and the Eddington ratio (\\xi=L_{X}(0.5-25 keV)/L_{Edd}) in six XRBs. We find that different XRBs follow different anti-correlations between $\\Gamma$ and $\\xi$ when $\\xi$ is less than a critical value, while they follow the same positive correlation when $\\xi$ is larger than the critical value. This anti-correlation and positive correlation are also found in LLAGNs and QSOs respectively, and the anti-correlation and positive correlation of different XRBs roughly converge to the same point ($\\log \\xi=-2.1, \\Gamma=1.5$), which may correspond to the accretion mode transition, since that the anti-correlation and positive correlation are consistent with the prediction of ADAFs and standard disk/corona system respectively. The traditional low/hard state are divided into two parts by the cross point $\\log \\xi\\sim-2.1$, i.e., faint-hard state in the ...
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Micro-Vickers hardness measurement has been used to determine the composition of functionally graded materials (FGMs). Materials used in the present study are Al-SiC, Al-Shirasu and Al-Al{sub 3}Ni FGMs, which are fabricated by a centrifugal method. The micro-hardness of the aluminum matrix for Al-SiC FGM markedly increases as the volume fraction of SiC particles increases. However, the tendency is not so clear in the cases of Al-Shirasu and Al-Al{sub 3}Ni FGMs. Plastic strain energy due to thermal misfits between the matrix and dipersed particles is calculated based on an elasto-plastic analysis by applying a shell theory after Lee et al. The hardness is correlated theoretically with the composition gradient through the mean plastic strain energy (responsible for dislocation density). It is concluded that the composition gradient of metal-based FGMs can be determined from micro-hardness measurements. ...
2001-01-01
Hard X-ray identification of Eta Carinae and steadiness close to periastron
Context: The colliding-wind binary Eta Car exhibits soft X-ray thermal emission that varies strongly around periastron, and non-thermal emission seen in hard X-rays and gamma-rays. Aims: To definitively identify Eta Car as the source of the hard X-ray emission, to examine how changes in the 2-10 keV band influence changes in the hard X-ray band, and to understand more clearly the mechanisms producing the non-thermal emission using new INTEGRAL observations obtained close to periastron. Methods: A Chandra observation encompassing the ISGRI error circle was analysed, and all other soft X-ray sources (including the outer shell of Eta Car itself) were discarded as likely counter-parts. New hard X-ray images of Eta Car were studied close to periastron, and compared to previous observations far from periastron. Results: The INTEGRAL component, when represented by a power law (with a photon index of 1.8), ...
2010-01-01
Accretion Properties of A Sample of Hard X-ray (<60keV) Selected Seyfert 1 Galaxies
We examine the accretion properties in a sample of 42 hard (3-60keV) X-ray selected nearby broad-line AGNs. The energy range in the sample is harder than that usually used in the similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey (XSS), and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad H$\\beta$ emission line. The tight correlation between the hard X-ray (3-20keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the H$\\beta$ emission line. In addition, all these hard X-ray AGNs are biased toward luminous objects with high Eddington ratio (mostly between 0.01 to 0.1) and low column density ($<10^{22} \\mathrm{cm^{-2}}$), which is most likely due to the selection effect of ...
2008-01-01
Nanofocusing refractive X-ray lenses
Energy Technology Data Exchange (ETDEWEB)
This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where several single lenses ...
2010-02-05
Microfabricated polyester conical microwells for cell culture applications.
Over the past few years there has been a great deal of interest in reducing experimental systems to a lab-on-a-chip scale. There has been particular interest in conducting high-throughput screening studies using microscale devices, for example in stem cell research. Microwells have emerged as the structure of choice for such tests. Most manufacturing approaches for microwell fabrication are based on photolithography, soft lithography, and etching. However, some of these approaches require extensive equipment, lengthy fabrication process, and modifications to the existing microwell patterns are costly. Here we show a convenient, fast, and low-cost method for fabricating microwells for cell culture applications by laser ablation of a polyester film coated with silicone glue. Microwell diameter was controlled by adjusting the laser power and speed, and the well depth by stacking several layers of film. By using this setup, a device containing hundreds of microwells can be fabricated in a ...
2011-05-26
We present a femtosecond Laser Two-Photon Polymerization (LTPP) system of large scale three-dimensional structuring for applications in tissue engineering. The direct laser writing system enables fabrication of artificial polymeric scaffolds over a large area (up to cm in lateral size) with sub-micrometer resolution which could find practical applications in biomedicine and surgery. Yb:KGW femtosecond laser oscillator (Pharos, Light Conversion. Co. Ltd.) is used as an irradiation source (75 fs, 515 nm (frequency doubled), 80 MHz). The sample is mounted on wide range linear motor driven stages having 10 nm sample positioning resolution (XY--ALS130-100, Z--ALS130-50, Aerotech, Inc.). These stages guarantee an overall travelling range of 100 mm into X and Y directions and 50 mm in Z direction and support the linear scanning speed up to 300 mm/s. By moving the sample three-dimensionally the position of laser focus in the photopolymer is changed and one is able to write complex 3D ...
2010-11-10
International Nuclear Information System (INIS)
The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.
2009-09-07
Photon dosimetry using plastic scintillators in pulsed radiation fields
Energy Technology Data Exchange (ETDEWEB)
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...
2007-04-01
Neutron radiography with the cyclotron, 4
International Nuclear Information System (INIS)
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual application to dynamical fluid motion of ...
1986-01-01
Detection system characteristics using sup 252 Cf ionization chambers
Energy Technology Data Exchange (ETDEWEB)
Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This paper illustrates the use of this type of source to determine ...
1990-01-01
International Nuclear Information System (INIS)
In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The detector is ...
1992-03-16
Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices
International Nuclear Information System (INIS)
Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, involving short distances ...
2005-10-23
Zinc determination in medicinal powders by radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).
1977-01-01
Use of activated charcoal for the purification of neon in the CLEAN experiment
Energy Technology Data Exchange (ETDEWEB)
Passage of neon gas through activated charcoal is planned to be the primary method of removing impurities from the liquid neon scintillator in the CLEAN experiment. In order to quantify this technique, the breakout curves for hydrogen, nitrogen, argon and krypton impurities in neon-saturated activated charcoal were measured. Adsorption coefficients and the number of theoretical stages were measured for hydrogen in the temperature range between 300 and 80 K, nitrogen between 300 and 200 K, and argon between 300 and 190 K. The adsorption coefficient for krypton was measured at 300 K.
2007-01-21
The hunt for ?13 at the Daya Bay nuclear power plant
International Nuclear Information System (INIS)
The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.
2010-03-30
The AMS-02 electromagnetic calorimeter
The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).
2002-01-01
Radon grab sampling in water by means of radon transfer in activated charcoal collectors
Energy Technology Data Exchange (ETDEWEB)
The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.
1999-08-01
Energy Technology Data Exchange (ETDEWEB)
Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is ...
2007-12-15
Precise Measurement of the Neutron Magnetic Form Factor G{sub M}{sup n} in the Few-GeV{sup 2} Region
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
2009-05-15
Precise Measurement of the Neutron Magnetic Form Factor GMn in the Few-GeV2 Region
International Nuclear Information System (INIS)
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
2009-05-15
International Nuclear Information System (INIS)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-01
Energy Technology Data Exchange (ETDEWEB)
Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.
1994-07-01
Air Shower Events of High-Energy Cosmic Rays Measured at Seoul, South Korea
The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.
2011-09-01
Systematics of high temperature perturbation theory: The two-loop electron self-energy in QED
International Nuclear Information System (INIS)
In order to investigate the systematics of the loop expansion in high temperature gauge theories beyond the leading order hard thermal loop (HTL) approximation, we calculate the two-loop electron proper self-energy #SIGMA# in high temperature QED. The two-loop bubble diagram of #SIGMA# contains a linear infrared divergence. Even if regulated with a nonzero photon mass M of order of the Debye mass, this infrared sensitivity implies that the two-loop self-energy contributes terms to the fermion dispersion relation that are comparable to or even larger than the next-to-leading order (NLO) contributions of the one-loop #SIGMA#. Additional evidence for the necessity of a systematic restructuring of the loop expansion comes from the explicit gauge-parameter dependence of the fermion damping rate at both one and two loops. The leading terms in the high temperature expansion of the two-loop self-energy for all topologies arise from an explicit ...
2010-01-15
Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination
Energy Technology Data Exchange (ETDEWEB)
The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...
2000-07-01
The JT-60U 2.45 MeV neutron time-of-flight spectrometer
Energy Technology Data Exchange (ETDEWEB)
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. The useful countrate for this case is ...
1999-11-01
A large surface neutron and photon detector for civil security applications
Energy Technology Data Exchange (ETDEWEB)
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
2010-05-21
A large surface neutron and photon detector for civil security applications
International Nuclear Information System (INIS)
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
2010-05-11
WC-TiC-Ni cemented carbide with enhanced properties
British Library Electronic Table of Contents (United Kingdom)
In the paper, the effect of Ni content, WC grain size and Mo2C addition on WC-6.25wt%TiC-9.3wt%Ni cemented carbide were investigated to improve the properties of Ni-bonded cemented carbides. The results show that the decrease of Ni content will result in the decrease of transverse rupture strength and increase of hardness; with the decrease of WC particle size, hardness increases due to the refinement of WC grains, however, the transverse rupture strength decrease due to the decrease of Ni binder thickness; Mo2C proves to be an effective grain growth inhibitor. With the increase of Mo2C content, the WC grains are refined and the hardness and transverse rupture strength are improved. Generally, when the Ni content is decreased to 8.4wt%, 13.45mm WC is used and 1.2wt% Mo2C is added, a higher...
2008-01-01
Radiation hardening of smart electronics
International Nuclear Information System (INIS)
Microprocessor based ''smart'' pressure, level, and flow transmitters were tested to determine the radiation hardness of this class of electronic instrumentation for use in reactor building applications. Commercial grade Complementary Metal Oxide Semiconductor (CMOS) integrated circuits used in these transmitters were found to fail at total gamma dose levels between 2500 and 10,000 rad. This results in an unacceptably short lifetime in many reactor building radiation environments. Radiation hardened integrated circuits can, in general, provide satisfactory service life for normal reactor operations when not restricted to the extremely low power budget imposed by standard 4--20 mA two-wire instrument loops. The design of these circuits will require attention to vendor radiation hardness specifications, dose rates, process control with respect to radiation hardness factors, and non-volatile programmable memory technology. 3 ...
High temperature properties of ceramics in the SiAlON system
International Nuclear Information System (INIS)
A series of SiAlON materials with a cordierite-based matrix were annealed for different lengths of time to cause crystallization of the glass phase. Their fracture toughness, hardness, and elastic modulus were measured from room temperature up to 1100"0C. The fracture toughness generally decreased with temperature. Short time annealing raised toughness at lower temperatures, while further annealing lowered it back to the value for as-hot pressed materials. At higher test temperatures annealing had no effect on toughness. This annealing behavior is significantly different from that previously reported in the system SaAlON-YAG. Hardness decreased monotonically with temperature for all samples. Both hardness and the elastic modulus were not affected by the annealing treatment. At elevated temperatures appreciable scatter of modulus results allowed only a rough trend of decrease with temperature to be observed.
First derivative of the hard-sphere radial distribution function at contact
Energy Technology Data Exchange (ETDEWEB)
Molecular dynamics simulations have been carried out of the radial distribution function of the hard sphere fluid for a range of densities in the equilibrium fluid and just into the metastable region. The first derivative of the hard-sphere radial distribution function at contact was computed and its density dependence fitted to a simple analytic form. Comparisons were made with semi-empirical formulae from the literature, and of these the formula proposed by Tao et al (1992 Phys. Rev. A 46 8007) was found to be in best agreement with the simulation data, although it slightly underestimates the derivative at the higher packing fractions in excess of about 0.45. Close to contact, within a few per cent of the particle diameter, the radial distribution function can be represented well by a second order polynomial. An exponential function, which has some useful analytic features, can also be applied in this region.
2006-08-16
British Library Electronic Table of Contents (United Kingdom)
PurposeThe purpose of this study was to determine the relationship between the changes of soft and hard tissues after modified anterior segmental osteotomy on the maxilla and mandible and to evaluate unintended facial changes using cephalometric and photometric analyses.Materials and MethodsThe subjects included 29 women and 1 man (22 to 50 years of age) who were diagnosed as bialveolar or bimaxillary protrusion and underwent modified anterior segmental osteotomy on the maxilla and mandible. Lateral cephalograms and lateral and frontal photographs taken preoperatively and postoperatively were analyzed.ResultsThere was a significant change in all soft and hard tissue parameters except the labiomental angle. The ratio of upper lip to maxillary incisor retraction was 0.67:1 and the ratio of l...
2008-01-01
Equipment hardening and hardness assurance
International Nuclear Information System (INIS)
The introduction of tolerance to radiation (''radiation-hardness'') into large electronic systems is one of the major tasks to which this Handbook will be put. The practices recommended here for inculcating radiation-tolerance in equipment require advanced physical modeling techniques, precise engineering procedures, and firm assurance procedures. The degree to which these procedures should be used in an equipment project can be measured by the severity of the raw radiation environment, the desired reliability of the system, and the requirement of that project for radiation-sensitive technologies. The balance of device/circuit design versus shielding will depend on whether the radiation is highly penetrating -- as in isotope handling or military environments -- or readily attenuated, as in space. In this chapter the authors have attempted to summarize the essential features of the radiation hardening of large assemblies of equipment and how effective control of ...
Elastic properties, hardness and indentation fracture toughness of #beta#-sialons
International Nuclear Information System (INIS)
Dense samples of #beta#-sialons (with z from 1 to 4) were pressuressly sintered for different time (15-240 minutes) and at relatively low temperature of 1600 C using single-phase #beta#-sialon powders synthesized by combustion nitridation. The samples were characterized using ultrasonic method for determination of elastic properties (E,G,#mu#). Also, hardness by Knoop and fracture toughness by Vickers indentation microfracture method was estimated. With increasing z number Young's modulus decreases from 293 to 179 GPa. Simultaneously Poisson ratio increases by about 30%. The highest values of hardness and fracture toughness were obtained for sialon with z equal to 1. (orig.).
1993-10-04
Cumulative production of direct photons and leptonic pairs
International Nuclear Information System (INIS)
Leptonic pair production on nuclei ad EMC-effect are discussed within the frames of the flucton model with scaling distortion. Cumulative production of direct photons and leptonic pairs as a test of the model of hard collisions is considered. The results of calculations of massive leptonic pair production cross sections on nucleus fluctons, caculations of the ratio of deuterium and iron structural functions, cross sections of direct photon production on sup(181)Ta nuclei at Esub(p)=400 GeV and cross section of #pi#-meson production in the model of hard collisions are presented. Experimental discovery of direct cumulative photons is concluded to be important for understanding the mechanism of parton hard scattering from nucleus fluctons.
1984-06-19
Ceramic bearings for application to hard disc drives (HDD); HDD yo ceramic ball bearing
Energy Technology Data Exchange (ETDEWEB)
Ceramic ball bearings of silicon nitride are used for hard disk drive (HDD) spindle motors, to increase seed, reliability and memory capacity of the HDDs. Silicon nitride ceramics have advantages of lightweight, high strength and hardness over the conventional steel for bearings, but is expensive. A new process of high cost performance has been developed for mass production of the small-size ceramic balls. The company plans to apply these bearings to higher devices, e.g., servers, for the time being, and to expand the applicable areas, e.g., common devices and other small-size motors. The ceramic bearings have been developed jointly with Koyo Seiko Co. Ltd. (translated by NEDO)
2000-03-01
Wrinkled hard skins on polymers created by focused ion beam
UK PubMed Central (United Kingdom)
A stiff skin forms on surface areas of a flat polydimethylsiloxane (PDMS) upon exposure to focused ion beam (FIB) leading to ordered surface wrinkles. By controlling the FIB fluence and area of exposure...Full Text Available
2007-01-23
Theory of multifoil collision supercompression
Energy Technology Data Exchange (ETDEWEB)
Investigations of superdense compression touch on such problems as ultrahigh-frequency oscillations of matter in the generation of gravitational waves, the powerful pumping of hard coherent radiation, and the laboratory simulation of stellar interiors. This paper reviews the theory of supercompression and discusses some experiments involving multifoil collision supercompression.
1980-01-01
TO: All GCN Notice recipients RE
These sky images are scanned for point sources above a specified ... The threshold criteria are: a) Gold: >4 sigma in both the Soft AND Hard bands. b) Silver: ... Filtering: Currently, there is no plan for filtering within the GCN based ...
UK PubMed Central (United Kingdom)
ObjectiveTo implement a role-reversal exercise to increase first-year pharmacy students' awareness of communication barriers in the health care setting, especially for deaf and hard-of-hearing...Full Text Available
2011-04-11
UK PubMed Central (United Kingdom)
ObjectivesPericardial tamponade after cardiac surgery is difficult to diagnose, thereby rendering timing of rethoracotomy hard. We aimed at identifying factors predicting the outcome...Full Text Available
Position-sensitive proportional counter for space-based X-ray imaging studies
International Nuclear Information System (INIS)
ASTROSAT, India's first dedicated astronomy satellite is slated for launch in 2007. The primary science objective of ASTROSAT is to explore the Universe using broad-band instruments covering optical, UV, soft X-ray and hard X-ray studies
2005-03-01
Plasma nitriding of austenitic stainless steel in N_2 and N_2/H_2 gas admixture
International Nuclear Information System (INIS)
Plasma nitriding in glow discharge is a process of modifying surface properties of a material by which surface hardness, corrosion resistance, fatigue strength etc. of a material can be improved
2004-09-01
Pattern of seat belt use by drivers in Trinidad and Tobago, West Indies
UK PubMed Central (United Kingdom)
BackgroundIn Trinidad and Tobago, the law on the mandatory use of seat belts was passed in 1995, but this law is hardly enforced. The objective of this study was to determine the...Full Text Available
Nonlinear response of superconductors to alternating fields and currents
This report discusses the following topics on superconductivity: nonlinearities in hard superconductors such as surface impedance of a type II superconductimg half space and harmonic generation and intermodulation due to alternating transport currents; and nonlinearities in superconducting weak links such as harmonic generation by a long Josephson Junction in a superconducting slab.
1997-10-08
British Library Electronic Table of Contents (United Kingdom)
Ultra fine tungsten carbide and cobalt powders were milled by high energy planetary ball mill at different ball to powder weight ratios (BPR) to produce particles of WC-10wt%Co hard metal in nanometer scale size. Microstructural characterizations by TEM show that the particle size of tungsten carbide was achieved to 32nm after milling at 15 BPR during 10h. In order to reduce the WC grain growth during the sintering process, tantalum carbide was added to the hard metal as a WC grain growth inhibitor. The nano hard metal powders were compacted at 200MPa pressure and sintered at 1370-1450degreeC temperatures in a high purity hydrogen atmosphere. The results show that the addition of 0.6wt% of TaC improves the hardness and fracture toughness from 1493 HV30 and 11.8MPam (for TaC free sample) to...
2009-01-01
Mechanical properties of excimer laser modified titanium surfaces
Energy Technology Data Exchange (ETDEWEB)
Excimer laser processing enables both thermally-driven transformations and the incorporation of solutes into the surface of materials through melting and diffusional mixing. We have examined the effect of excimer laser processing on the microstructure and surface mechanical properties of titanium alloys. Changes in the surface hardness due to laser processing were studied using a Nanoindenter [trademark]. Alloying experiments using both mixing of evaporated surface layers of boron and laser gas alloying in air and in nitrogen all result in changes in the surface hardness of the material. Alloying with boron results in an amorphous surface which is somewhat harder than the as polished surface. Laser processing in air and pure nitrogen results in incorporation of oxygen and nitrogen and the development of fine ([approximately] 50 nm) precipitates of TiO and TiN respectively. Substantial increases in surface hardness result ...
1993-01-01
Making simple sentences hard: Verb bias effects in simple direct object sentences
UK PubMed Central (United Kingdom)
Constraint-based lexical models of language processing assume that readers resolve temporary ambiguities by relying on a variety of cues, including particular knowledge of how verbs combine...Full Text Available
2009-04-01
Learning the Hard Way: Force Protection 1983-2000.
The October 2000 terrorist attack on the guided-missile destroyer USS Cole (DDG 67) in the port of Aden, Yemen, is commonly viewed in the larger context of al-Qa'ida's September 11th campaign. Beyond the initial official investigations, the military force...
2009-01-01
Laser hardening of titanium-zirconium alloy
International Nuclear Information System (INIS)
The methods of surface modification of Ti-Zr alloy by laser treatment are considered. Characteristics of laser modification without- and with surface melting and with melting in different gaseous environments and with nickel microalloying are presented. Maximum depth, hardness and corrosion resistance are observed under nickel laser alloying.
Energy Technology Data Exchange (ETDEWEB)
An ex-employee's claims that inadequate enforcement of radiation safety regulations allowed excess radiation exposure thereby causing his deteriorating health was not substantiated by a thorough investigation.
1981-03-01
Hardening by point defects in neutron irradiated AlN and SiC
International Nuclear Information System (INIS)
Pressureless-sintered AlN and hot-pressed, pressureless-sintered and reaction-bonded SiC were neutron irradiated at temperatures between 100 and 785degC up to a fluence of 5.2 x 10"2"4 n/m"2. The hardness was increased by up to 51% in AlN and 84% in SiC. The hardness decreased after annealing at temperatures around the irradiation temperature. At the same temperatures, the macroscopic length, which was increased by irradiation, also began to decrease. The hardness and length were almost recovered after 1,200 #approx# 1,400degC annealing. Thus, hardening in irradiated AlN and SiC is controlled by the number of point defects, or, more precisely, by the strain caused by small point defect clusters which pin down dislocation movement. Dislocation loops were still observed in some samples after 1,400degC annealing while the hardness was almost recovered to that in the unirradiated state. Thus, the existence ...
Evolving hard problems: Generating human genetics datasets with a complex etiology
UK PubMed Central (United Kingdom)
BackgroundA goal of human genetics is to discover genetic factors that influence individuals' susceptibility to common diseases. Most common diseases are thought to result from the...Full Text Available
UK PubMed Central (United Kingdom)
Plant surfaces covered with crystalline epicuticular waxes are known to be anti-adhesive, hardly wettable and preventing insect attachment. But there are insects that are capable of gluing their eggs...Full Text Available
2010-03-22
International Nuclear Information System (INIS)
68 replaced carbon steel piping in secondary system of pressurized water reactor (PWR) has been investigated by visual examination for checking thinning conditions. It is well known that the flow-accelerated corrosion (FAC) was inhibited by traces of Cr in steel. Therefore, the chemical compositions of those steels have been measured. In addition, the micro structure and hardness of those steels have been investigated. And the relationship between those material variables and FAC rate was considered. As the results, (1) The Cr contents in those steels were below 0.1 wt% except one sample. Minute quantities of chromium increase the resistance against FAC. But the water velocity was thought to be the dominant factor rather than chemical composition in steel, at least such as below 0.1%Cr. (2) Hardness of all piping has been satisfied the specifications of each materials. The hardness of steels was not correlated with wall ...
2008-10-01
UK PubMed Central (United Kingdom)
Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available
2005-10-01
Adhesion of DOPA-Functionalized Model Membranes to Hard and Soft Surfaces
UK PubMed Central (United Kingdom)
The adhesive proteins secreted by marine mussels form a natural glue that cures rapidly to form strong and durable bonds in aqueous environments. These mussel adhesive proteins contain an unusual...Full Text Available
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Deposition of hard coatings may influence the mechanical properties of the bulk material and its corrosion resistance. In this work we study the hardness of the coated and the back side of 100Cr6 steel plates. Electrochemical corrosion tests were performed in O{sub 2}-saturated acetate buffer of pH 5.6 at 25degC. Chromium nitride and titanium nitride coatings prepared by different physical vapour deposition processes, such as arc, thermionic arc evaporation, magnetron sputtering and ion-beam-assisted deposition (IBAD) were compared. The results show that, for sufficient corrosion protection, chromium nitride layers have to be thicker than 500 nm. An increased nitrogen partial pressure in the evaporation chamber of the IBAD process improves the corrosion resistance significantly. The hardness of the substrates was reduced in the case of thermoionic arc evaporation only, indicating a deposition temperature of more than ...
1991-07-07
Wear resistance of a laser surface alloyed Ti-6Al-4V alloy
Energy Technology Data Exchange (ETDEWEB)
Laser surface alloying with gaseous nitrogen was utilized to improve the wear resistance of a Ti-6Al-4V alloy. Wear-resistant composite coatings reinforced by hard TiN dendrites were produced 'in-situ' on a substrate of a Ti-6Al-4V alloy. The hardness and wear resistance of the laser alloyed coating under two-body abrasive and block-on-ring full-sliding wear conditions were significantly enhanced. (orig.)
2000-08-01
Numerical prediction of flow field and particle trajectory in a hard disk drive
Energy Technology Data Exchange (ETDEWEB)
A flow field and particle trajectory in a HDD (Hard Disk Drive) between two rotating disks in axisymmetric enclosures is investigated using CFD code FLUENT/UNS. The RNG k-{epsilon} model is used as a turbulent model. In this study, the flow field between two disks are symmetric, and the flow field near the enclosure is very complex. Cross stream vectors are shown both for blowing and no blowing from the hub. The larger a particle, the more fast the particle deposits at the walls. In the case of blowing from the hub, the more fast the particle deposits at the walls. (author). 9 refs., 12 figs., 1 tab.
1999-11-01
Manufacturing of golf club using wood-plastic combination produced by. gamma. -irradiation
Energy Technology Data Exchange (ETDEWEB)
Wood-plastic combination (WPC) was produced by {gamma}-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).
1992-01-01
Manufacturing of golf club using wood-plastic combination produced by #gamma#-irradiation
International Nuclear Information System (INIS)
Wood-plastic combination (WPC) was produced by #gamma#-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).
1992-01-01
Hard X-ray phase imaging and tomography using a grating interferometer
International Nuclear Information System (INIS)
An interferometric technique for hard X-rays is presented. It is based on two transmission gratings and a phase-stepping technique, and it provides separate radiographs of the phase and absorption profiles of bulk samples. Tomographic reconstruction yields quantitative three-dimensional maps of the X-ray refractive index and of the attenuation coefficient, with a spatial resolution down to a few microns. The method is mechanically robust, it requires little monochromaticity, and can be scaled up to large fields of view. These are important prerequisites for use with laboratory X-ray sources. Numerous applications ranging from wave front sensing to medical radiography are presently under investigation.
2007-07-01
Glow Discharge Plasma Nitriding of AISI 304 Stainless Steel
International Nuclear Information System (INIS)
Glow discharge plasma nitriding of AISI 304 austenitic stainless steel has been carried out for different processing time under optimum discharge conditions established by spectroscopic analysis. The treated samples were analysed by X-ray diffraction (XRD) to explore the changes induced in the crystallographic structure. The XRD pattern confirmed the formation of an expanded austenite phase (#gamma#_N) owing to incorporation of nitrogen as an interstitial solid solution in the iron lattice. A Vickers microhardness tester was used to evaluate the surface hardness as a function of indentation depth (#mu#m). The results showed clear evidence of surface changes with substantial increase in surface hardness.
2007-08-01
The effects of variable hardness, pH, alkalinity, humics, and suspended clay on the chemical speciation of copper and its toxicity to fathead minnow larvae in Lake Superior water were investigated. Two proposed methods (toxicity factors and chemical speciation) for predicting LC50 values in specific natural waters from laboratory toxicity data and the average site specific values of general water quality parameters were evaluated. The accuracy of the cupric ion-selective electrode in determining CU/sup +2/ activities in ambient and chemically altered Lake Superior water was also determined.
1986-03-01
Distribution of 6q-fluctons in nuclei and quark enhancement of hard processes with deuteron emission
International Nuclear Information System (INIS)
The distributions of the effective numbers of 6q-fluctons in the energy, momentum and distance to the center of mass of nucleus are studied. Many characteristics of these distributions are shown to be universal, i.e. independent of the flucton size. The saturation of the flucton density in A > 80 nuclei and other peculiarities are found, which define different behavior of the effective numbers of fluctons and deuterons. This fact provides an explanation of the known underestimate by a factor of 1.5-6 of the cross sections of hard inclusive (p, p'd) process on nuclei calculated in the quasi-elastic approximation.
Current situation of steel industry and coking coal industry and expectations for Canadian coal
Energy Technology Data Exchange (ETDEWEB)
The world steel industry and market and the current status and prospects for the Japanese steel industry are discussed with particular reference to China, Europe, and the US. Trends in coking coal supply from Australia, Canada, and Mongolia and changes in demand for hard and semi-soft coking coals are considered. Canadian coal plays a significant role in the hard coking coal and PCI coal markets. This is expected to continue. Emerging concerns include the strong Canadian dollar and increases in fuel and materials costs. Canadian suppliers are asked to improve efficiencies, be competitive in the overall coal chain, and diversify their PCI coal reserves. 14 figs.
2006-07-01
A low temperature synthesized NbC grain growth inhibitor in WC-Co hardmetal alloy
Energy Technology Data Exchange (ETDEWEB)
The efficiency of NbC on WC grain coarsening in a WC-10wt.%Co hardmetal alloy was demonstrated by hardness measurement and WC granulation observation. The heterogeneous and overall grain growth were controlled. A low temperature experimentally produced NbC was used and compared to the inhibition potential of a commercial NbC powder. The results were the same in terms of structural fineness and hardness. The dispersion of the experimental NbC was not a problem, in spite of its size. The experimental NbC has very large particles, formed by agglomerates of small crystallites. During milling these agglomerates could be broken down. (orig.)
2001-07-01
RF plasma nitriding of severely deformed iron-based alloys
International Nuclear Information System (INIS)
The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10"-"5 bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of #epsilon# and #gamma#' nitrides in the compound layer, with a preferential formation of #gamma#' at the expense of the #alpha#-phase at the higher nitriding ...
2003-05-15
Transuranic separation using organophophorus extractants adsorbed onto superparamagnetic carriers.
Energy Technology Data Exchange (ETDEWEB)
Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the chemistry and ...
1998-10-07
The PAMELA space experiment: first year of operation
Energy Technology Data Exchange (ETDEWEB)
On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.
2008-05-15
Study of the light yield of LuAP:Ce scintillating crystals
Energy Technology Data Exchange (ETDEWEB)
We have obtained optically clear samples of LuAP:Ce from the Institute of Physical Research, Ashtarak, Armenia, measuring up to 5x5x40 mm{sup 3}. The photo electron yield for a number of theses samples was measured with a Philips XP2020Q photomultiplier tube, and 556 photo electrons per MeV was obtained for the best samples. This is comparable to what is obtained from BGO crystals under the same condition, but a factor of 5 less than what is obtained with an LSO sample of similar dimensions. The light in LuAP:Ce increases with cerium concentration between 0.13 and 0.47%.
1996-12-31
Standardisation of "2"1"0Pb by Cerenkov counting
International Nuclear Information System (INIS)
A standard of "2"1"0Pb in solution was produced at the National Physical Laboratory by a novel technique combining Cerenkov counting with the established liquid scintillation efficiency tracing technique known as the CIEMAT/NIST method. Coincidence counting was applied in order to validate the measurements and the activity concentrations of the solution determined with each technique are shown to be in agreement. Radiochemical separation of the "2"1"0Pb from its daughters was also necessary and the scheme for the separation is described. After performing this two-stage standardisation, the uncertainty was successfully lowered to 0.66% (k=1). This uncertainty is approximately a factor of four lower than previously achieved at NPL by the classical method of standardisation of radionuclides, i.e. coincidence counting.
2011-05-01
Segmented focal plane detector for light and heavy ions
Energy Technology Data Exchange (ETDEWEB)
A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).
1992-06-15
Radon measurements at the FEMP
Energy Technology Data Exchange (ETDEWEB)
Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.
1993-08-01
PET/MRI hybrid imaging: devices and initial results
British Library Electronic Table of Contents (United Kingdom)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
2008-01-01
Neutrino cross sections with the MINER?A Experiment
British Library Electronic Table of Contents (United Kingdom)
MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...
2011-01-01
Multi-GeV electron spectrometer
Energy Technology Data Exchange (ETDEWEB)
The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...
2010-11-11
Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons
Energy Technology Data Exchange (ETDEWEB)
A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.
1990-01-01
Selenium 79 is a beta emitter produced from (235)U fission and is one of the long half-life radionuclides of interest in nuclear waste disposal problematic because of its potential migration capacity to the surface environment. Measurement of (79)Se is particularly difficult due to its low activity in waste matrices (about 10(-3)Bqg(-1)). A radiochemical procedure based on ion exchange separations was already described in a previous paper. This work presents different applications of the radiochemical separation to waste samples and an improvement of this procedure, including a selective extraction of selenium as diethylselenium in an organic solvent followed by a re-extraction in aqueous medium. This additional step allows the decontamination factor to be increased with the aim of counting (79)Se by liquid scintillation counting. PMID:19071740
2007-01-14
Energy Technology Data Exchange (ETDEWEB)
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
2004-04-15
International Nuclear Information System (INIS)
The electronic structures of the set of molecular clusters of dielectric oxide crystals AWO4 (A = Pb, Cd, Zn), the sizes of which increase sequentially are ab-initio calculated by the Restricted Hartree-Fock (RHF) method. The results of calculations of molecular orbitals and energy dependences of partial densities of electronic states of different clusters are compared each to other and to experimental data. It is found that calculated electronic structures of the tungstate groups and cations which are surrounded in cluster by certain number of the nearest neighbor atoms of the crystals quite well represent the experimentally obtained value of the forbidden gap of corresponding AWO4 crystal. (authors)
A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor
Energy Technology Data Exchange (ETDEWEB)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
2002-07-01
A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor
International Nuclear Information System (INIS)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
Energy Technology Data Exchange (ETDEWEB)
We have investigated the effect of plasma nitriding and plasma nitrocarburizing on the microstructure and properties of electroplated chromium. Plasma nitriding and plasma nitrocarburizing are applied to 15-100 [mu]m thick electroplated hard chromium coatings to increase both the wear and the corrosion resistance. The properties of the plasma-modified hard chromium layers are characterized by measuring the wear resistance with a Taber wear tester and the corrosion resistance with a salt spray fog test. Cyclic voltammetry is performed in a standard electrochemical cell using a 0.5 M H[sub 2]SO[sub 4] solution acidified to pH 0.3. The compound layer after plasma nitriding consists of CrN and Cr[sub 2]N with a maximum hardness of about 1100 HK[sub 0.01]. After plasma nitrocarburizing, Cr[sub 3]C[sub 2] and Cr[sub 7]C[sub 3] are formed. After plasma nitrocarburizing, the maximum hardness is increased up to ...
1999-02-01
Hard spectator interactions in B {yields} {pi}{pi} at order {alpha}{sup 2}{sub s}
Energy Technology Data Exchange (ETDEWEB)
In the present thesis I discuss the hard spectator interaction amplitude in B {yields} {pi}{pi} at NLO i.e. at O({alpha}{sup 2}{sub s}). This special part of the amplitude, whose LO starts at O({alpha}{sub s}), is defined in the framework of QCD factorization. QCD factorization allows to separate the short- and the long-distance physics in leading power in an expansion in {lambda}{sub QCD}/m{sub b}, where the short-distance physics can be calculated in a perturbative expansion in {alpha}{sub s}. Compared to other parts of the amplitude hard spectator interactions are formally enhanced by the hard collinear scale {radical}({lambda}{sub QCD}m{sub b}), which occurs next to the mb-scale and leads to an enhancement of {alpha}{sub s}. From a technical point of view the main challenges of this calculation are due to the fact that we have to deal with Feynman integrals that come with up to five external legs and with three ...
2007-05-31
Graded layer design for stress-reduced and strongly adherent superhard amorphous carbon films
Energy Technology Data Exchange (ETDEWEB)
Diamond-like carbon thin films for tribological applications were deposited by d.c.-magnetron sputtering of a graphite target in a pure argon atmosphere or in a reactive hydrogen or methane atmosphere at pressures between 0.1 and 1 Pa in a graded constitution to improve adhesion and reduce residual stress. The temperature of the metallic, carbon- and ceramic-like substrates was below 100 C. The mechanical, thermal, electronic and optical properties of the carbon thin films show a significant dependence on the ion energy. Below 220 eV, strongly adherent black conductive films with hardness values up to 2000 HV0.05 were obtained. Hard and superhard diamond-like carbon thin films were deposited in an energy range between 220 and 370 eV with hardness values up to 4000 HV0.05. They are insulating, optically transparent and show a high degree of hardness combined with high compressive stress in the order of 4 ...
1999-09-01
Advanced Underground Gas Storage Concepts: Refrigerated-Mined Cavern Storage, Final Report
Energy Technology Data Exchange (ETDEWEB)
Over the past 40 years, cavern storage of LPG's, petrochemicals, such as ethylene and propylene, and other petroleum products has increased dramatically. In 1991, the Gas Processors Association (GPA) lists the total U.S. underground storage capacity for LPG's and related products of approximately 519 million barrels (82.5 million cubic meters) in 1,122 separate caverns. Of this total, 70 are hard rock caverns and the remaining 1,052 are caverns in salt deposits. However, along the eastern seaboard of the U.S. and the Pacific northwest, salt deposits are not available and therefore, storage in hard rocks is required. Limited demand and high cost has prevented the construction of hard rock caverns in this country for a number of years. The storage of natural gas in mined caverns may prove technically feasible if the geology of the targeted market area is suitable; and economically feasible if the cost and ...
1998-09-30
Energy Technology Data Exchange (ETDEWEB)
Sintered glass-ceramics were produced from coal fly ashes, red mud from aluminum production and silica fume. The capabilities of Tuncbilek fly ash and a mixture of Orhaneli fly ash, red mud and silica fume to be vitrified and devitrified by sintering process were investigated by means of scanning electron microscopy and X-ray diffraction analysis. To determine the effect of binder in the sintering technique, glass powders were pressed without or with the addition of polyvinyl alcohol. Owing to microstructural observations, density and hardness measurements, it can be said that physical properties and the hardness of the produced samples strongly depended on the crystallization degree of the samples. Toxicity characteristic leaching procedure test results showed that glass-ceramic samples produced by using sintering technique could be considered as nonhazardous materials. Chemical durability of the sintered glass-ceramic samples was also good. ...
2009-09-15
Stereoscopic observations of a solar hard x-ray flare with Ulysses, PVO, GRO and Yohkoh spacecraft
Energy Technology Data Exchange (ETDEWEB)
Hard X-ray/gamma-ray spectrometers aboard two interplanetary spacecraft, Ulysses and Pioneer Venus Orbiter (PVO), and two near-Earth spacecraft, Yohkoh and Compton Gamma Ray Observatory (GRO/BATSE), are currently in operation. A unique set of circumstances have permitted the observation of the 15 November 1991 (2238 UT) flare by all the four instruments. This intense flare (GOES class X 1.5) was associated with the bright (3B) H-alpha flare located on the disk (S13, W19) in the active region 6919. At the time of the flare, the Ulysses and PVO spacecraft were located respectively 101[degree] and 52[degree] west of the Sun-Earth line. Thus the view angles for the PVO and Ulysses instruments were quite different from those of the near-Earth instruments on GRO and Yohkoh. The preliminary photon energy spectra observed by the four instruments at different times during the flare will be presented and their implications regarding the directivity of ...
1992-01-01
Radiation effects on MOS devices and radiation-hard CMOS technologies
International Nuclear Information System (INIS)
Total-dose irradiation seriously damages MOS devices and their circuit performance. Threshold voltage shifts, transconductance degradation and increase in off-state leakage current are generally observed for irradiated devices. These instabilities are essentially due to positive and/or negative charge trapping in SiO_2 and interface trap generation at the SiO_2/Si interface. Radiation hardening of CMOS VLSIs is to eliminate these trapping effects, and for this purpose, special considerations for fabrication processes and layout design are necessary. In this paper, basic mechanisms for radiation-induced charge trapping and related effects on MOS devices are reviewed. Also discussed are radiation-hardening technologies from both fabrication-process and layout-design viewpoints. Using these technologies, 1 #mu#m radiation-hard CMOS gate arrays have been successfully developed. Experimental data taken for 2k-gate test chips indicate that radiation ...
Properties and challenges of nanolayer coatings
Energy Technology Data Exchange (ETDEWEB)
A systematic study was made on MoSi{sub 2}-based nanolayer coatings. Alternating layers with thickness 1-20 nm were prepared by sputtering. Nitrided MoSi{sub 2} has a very high crystallization temperature, >1000 C, and MoSi{sub 2}Nx (x=3-4) can be used as a stable second phase reinforcement or diffusion barrier coatings. Mechanical properties depend strongly on phase and morphology of the layers: hardness and modulus is significantly increased in the crystallization. The nanolayers have much higher hardness but lower modulus (which project higher toughness in the nanolayers). Wear resistance is improved with decreasing layer thickness. Single phase MoSi{sub 2}Nx (x=0-4.2) has a wide range of hardness and modulus with varying N content and annealing, suggesting the possibility of engineering MoSi{sub 2}Nx to produce different material properties for different mechanical applications. Most of this paper is made up of ...
1995-12-01
Phase formation in selected surface-roughened plasma-nitrided 304 austenite stainless steel
Energy Technology Data Exchange (ETDEWEB)
Direct current (DC) glow discharge plasma nitriding was carried out on three selected surface-roughened AISI 304 stainless steel samples at 833 K under 4 mbar pressures for 24 h in the presence of N{sub 2}:H{sub 2} gas mixtures of 50 : 50 ratios. After plasma nitriding, the phase formation, case depth, surface roughness, and microhardness of a plasma-nitrided layer were evaluated by glancing angle x-ray diffractogram, optical microscope, stylus profilometer, and Vickers microhardness tester techniques. The case depth, surface hardness, and phase formation variations were observed with a variation in initial surface roughness. The diffraction patterns of the plasma-nitrided samples showed the modified intensities of the {alpha} and {gamma} phases along with those of the CrN, Fe{sub 4}N, and Fe{sub 3}N phases. Hardness and case depth variations were observed with a variation in surface roughness. A maximum hardness of 1058 Hv ...
2008-04-01
Observed energy dependence of Fano factor in silicon at hard X-ray energies
Energy Technology Data Exchange (ETDEWEB)
An experimental evaluation of the Fano factor F in silicon at hard X-ray energies (5.9-136.5 keV) has been performed by means of a low-noise, high charge collection efficiency silicon drift detector with on-chip electronics. A dependence of F from the detector temperature as well as from the energy of the X-ray photons has been found. Assuming a pair creation energy equal to 3.64 eV, at +20 deg. C the F factor was observed to vary from 0.124{+-}0.006 at 5.9 keV up to 0.159{+-}0.002 at 122 keV. At -35 deg. C, the change of F with respect to the photon energy was less remarkable but nevertheless statistically significant, from 0.123{+-}0.002 at 5.9 keV up to 0.134{+-}0.001 at 122 keV. To our knowledge, the present results represent the first experimental evidence of an energy dependence of the Fano factor in silicon at hard X-ray energies.
1999-03-01
Multilayered Nano-Microcomposite Ti-Al-N/TiN/Al_2O_3 Coatings. Their Structure and Properties
International Nuclear Information System (INIS)
This paper presents the first results on formation and study of structure and properties of micro- and nanocomposite combined coatings. By means of modeling the deposition processes (deposition conditions, current density-discharge, plasma composition and density, voltage) we formed the three-layer nanocomposite coatings of Ti-Al-N/Ti-N/Al_2O_3. The coating composition, structure and properties were studied using physical and nuclear-physical methods. The Rutherford proton and helium ion backscattering, scanning electron microscopy with microanalysis, grazing incidence X-ray diffraction, as well as nanohardness tests (hardness) were used. Measurements of wear resistance and corrosion resistance in NaCl, HCl and H_2SO_4 solutions were also performed. For testing mechanical properties such characteristics of layered structures as hardness H, elastic modulus E: H"3/E"2 etc. were measured. It is demonstrated that the formed three-layer ...
2011-07-01
Indentation plastic displacement field: Part II. The case of hard films on soft substrates
Energy Technology Data Exchange (ETDEWEB)
The plastic displacements around Knoop indentations made in hard titanium/aluminum multilayered films on soft aluminum alloy substrates have been studied. Indentations were cross-sectioned and imaged using the focused-ion-beam (FIB) milling and high-resolution scanning electron microscopy (SEM), respectively. The FIB milling method has the advantage of removing material in a localized region without producing mechanical damage to the specimen. The micrographs of the cross-sectioned indentations indicate that most of the plastic deformation around the indentation is dominated by the soft aluminum substrate. There is a very small change in the multilayered film thickness around the indentation{emdash}less than 10{percent}. The plastic deformation of the thin film resembles a membrane being deflected by a localized pressure gradient across the membrane. Stress-induced voids are also observed in the multilayered film, especially in the area around the indentation apex. ...
1999-06-01
Indentation modulus and hardness in heteroepitaxial Al{sub x}Ga{sub 1{minus}x}P films
Energy Technology Data Exchange (ETDEWEB)
Al{sub x}Ga{sub 1{minus}x}P layers (0 {le} x {le} 0.7), with thicknesses of {ge}1 {micro}m were grown on Si (100) wafers by metal-organic molecular beam epitaxy (MOMBE) at 450 C. Transmission electron micrographs of the single crystal films revealed that the microstructure contains stacking faults and microtwins especially near the interface as well as both threading and misfit dislocations. Hardness and elastic modulus were measured using a Nanotest 500 indenter, which can probe the film properties without influence from the substrate. The hardness H varies linearly according to (11.8 {minus} 2.3x) GPa. The absence of alloy hardening is due to the fact that there is no difference in atomic size of Al and Ga. The indentation modulus E/(1{minus}v{sup 2}) decreases monotonically from 136 GPa for GaP to 129 GPa for Al{sub 0.7}Ga{sub 0.3}P and bows only slightly (about 2%) below the straight line of linear interpolation.
1997-05-01
Effects of composition and temperature on irradiation hardening of pressure vessel steels
International Nuclear Information System (INIS)
The effects of key metallurgical variables on the low fluence hardening in a set of A533B model steels were evaluated over a wide range of irradiation temperatures. Above about 163 degrees C hardening increased with higher copper and nickel contents, as is typical of the pressure vessel operating regime around 290 degrees C. However, at 121 degrees C the hardening was generally lower and unaffected by copper and nickel variations. This observation of decreased hardening with lower temperature (e.g. an open-quotes invertedclose quotes temperature dependence) is tentatively attributed to a reduced contribution of copper precipitation. Tensile data for a set of commercial steels with a range of (uncontrolled) compositions also showed minimal sensitivity to copper variations at 121 degrees C. Unlike the hardness data no systematic reductions in the yield stress increases were observed between 163 and 121 degrees C. However, the ultimate tensile strength did decrease at ...
1991-08-25
Effects of DC plasma nitriding parameters on microstructure and properties of 304L stainless steel
International Nuclear Information System (INIS)
A wear-resistant nitrided layer was formed on a 304L austenitic stainless steel substrate by DC plasma nitriding. Effects of DC plasma nitriding parameters on the structural phases, micro-hardness and dry-sliding wear behavior of the nitrided layer were investigated by optical microscopy, X-ray diffraction, scanning electron microscopy, micro-hardness testing and ring-on-block wear testing. The results show that the highest surface hardness over a case depth of about 10 #mu#m is obtained after nitriding at 460 deg. C. XRD indicated a single expanded austenite phase and a single CrN nitride phase were formed at 350 deg. C and 480 deg. C, respectively. In addition, the S-phase layers formed on the samples provided the best dry-sliding wear resistance under the ring-on-block contact configuration test.
2009-03-01
Development of a new wear-resistant material: TiC/TiNi composite
Energy Technology Data Exchange (ETDEWEB)
In this work, an attempt was made to develop a novel type of wear-resistant composite employing a TiNi alloy matrix reinforced by hard particles. Titanium carbide was chosen as the reinforcing phase because of its high hardness and TiNi alloy as the matrix due to its pseudoelasticity and good toughness. TiC particles may sustain external load, while the TiNi matrix may accommodate deformation, absorb impact energy and retain the hard particles. Such a combination is expected to lead to an enhanced wear resistance, compared to TiNi alloy. As a matter of fact, some efforts were previously made to develop TiNi-matrix composite reinforced by ceramic particles. However, the emphasis of those studies was put on effects of the reinforcing particles on the phase transformation behavior, shape memory effect and some mechanical properties of the composite; no attempt was made to explore the potential benefit of the material for wear ...
1999-10-22
Aging and compatbility of TNF-doped mylar
Energy Technology Data Exchange (ETDEWEB)
TNF-doped Mylar is a new radiation-hard dielectric that has recently been qualified as a viable substitute for Mylar in capacitors. The advantage of TNF-doped Mylar is that it satisfies both the nuclear safety and radiation hardness requirements of weapons. Mylar is not radiation-hard. Aging and compatibility studies were carried out to insure that (1) TNF does not diffuse from the film during fabrication of the capacitor or during storage; and (2) there are no compatibility problems with aluminum foil (the conductor) or Fluorinert (the secondary dielectric). Losses of TNF were barely detectable during the vacuum bakes used in fabricating capacitors or during accelerated aging tests carried out below T{sub g} (70C) over a two year period in air. In other accelerated tests, no compatibility problems were detected with aluminum or Fluorinert. TNF-doped Mylar is now being used in the MC-4109 capacitor that was called out for ...
1990-01-01
Real-time neutron radiography; Radiografia com neutrons em tempo-real
Energy Technology Data Exchange (ETDEWEB)
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed ...
2000-07-01
Real-time neutron radiography at Texas A and M University
Energy Technology Data Exchange (ETDEWEB)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...
1990-12-20
Real-time neutron radiography at Texas A and M University
International Nuclear Information System (INIS)
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are used in place of the SIT camera. The computer digitizes the TV ...
1990-12-01
International Nuclear Information System (INIS)
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a computer. The device composed by the ...
2000-01-01
Energy Technology Data Exchange (ETDEWEB)
Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup 198}Au reaction cross section is a well known standard one. The result of the {sup ...
1997-07-01
RF plasma nitriding of severely deformed iron-based alloys
Energy Technology Data Exchange (ETDEWEB)
The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10{sup -5} bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of {epsilon} and {gamma}' nitrides in the compound layer, with a preferential formation of {gamma}' at the expense of the {alpha}-phase at the ...
2003-05-15
Properties and performance of new metastable Ti-B-C-N hard coatings prepared by magnetron sputtering
Energy Technology Data Exchange (ETDEWEB)
Thin films of new metastable materials from the system Ti-B-C-N were deposited on metallic substrates by d.c. magnetron sputtering in different Ar+N{sub 2} atmospheres. The multiphase compound targets used were based on various compositions on the TiC-TiB{sub 2} and TiB{sub 2}-C tie lines of the Ti-B-C phase diagram. The structure and chemical composition of the films were characterized by electron microprobe analysis, depth profiling Auger electron spectroscopy, X-ray diffraction and transmission electron microscopy. The hardness, critical load of failure and the tribological behavior of the coatings were investigated. Superhard single-phase crystalline metastable Ti-B-C-N layers with hardness values exceeding 5000 HV{sub 0.05} and extremely low sliding wear against 100Cr6 and Al{sub 2}O{sub 3} counterparts could be produced by reactive sputtering of various TiC-TiB{sub 2} targets in Ar+N{sub 2} atmospheres with low nitrogen flows. In the case ...
1995-10-01
Energy Technology Data Exchange (ETDEWEB)
The influences of temperature and duration of tempering on hardness and microstructure were investigated at high-temperature martensitic and low-carbon steels with 9% chrome and the further alloying elements molybdenium, vanadium, niobium and partially tungsten. After austenitizing and subsequent air cooling the steels were tempered at temperatures below, at and above Ac{sub 1b} for different times and finally a hardness test was performed. Making use of the temperature dependence of the hardness tempering diagrams were constructed and the Hollomon-Jaffe-Parameter on the three steels was determined within its application limits. Micrographs of the structure shows the formation of the carbides and the martensite. At tempering temperatures below Ac{sub 1b} a decrease of hardness occurs, above Ac{sub 1b}, a hardness rise due to the partial austenitizing was obtained. While hardening ...
1999-06-01
International Nuclear Information System (INIS)
Full text of publication follows: Radiation hardening and embrittlement due to high-energy neutron radiation around 623 K are the important issues on reduced-activation ferritic/martensitic (RAF/M) steels. It is expected that the improvement of radiation hardening might be one of effective ways to control the mechanical properties of RAF/M after irradiation. It has been reported that the weld joint has less hardening than the base metal from the tensile test results of TIG weldments irradiated in HFIR. This report indicated that radiation hardening can be reduced by the optimization of heat treatment condition for F82H. The purposes of this study are to establish the condition of heat treatment for minimum of radiation hardening in F82H steel using Neutron/Ion-irradiation and to examine a correlation between tensile property and micro-hardness before/after irradiation. The materials used in this study were F82H IEA heat and F82H heat treatment variants. Neutron ...
2007-12-10
Wood-plastic composites using woods native to Iran
International Nuclear Information System (INIS)
Radiation induced polymerization of methylmethacrylate and copolymerization of styrene-acrylonitrile mixture in mamrase Carpinus betulus was carried out by means of #gamma#-ray, under different moisture levels and additives. Under all conditions the degree of polymerization was as high as 60%. No pronounced differences were observed in the kinetics of the polymerization of MMA either with moisture content of wood nor with kind and amount of additives. At high moisture (80% RH) content the dimensional stability of wood-PMMA was increased four fold as compared with untreated wood. The hardness increased about 100% for a weight conversion of monomer of about 30 to 40%. Hardness of this wood-polymer composite is comparable to that of the best noble woods in the world. (author).
1978-10-26
Transverse Imaging of the Proton in Exclusive Diffractive pp Scattering
Energy Technology Data Exchange (ETDEWEB)
In a forthcoming paper we describe a new approach to rapidity gap survival (RGS) in the production of high-mass systems (H = dijet, Higgs, etc.) in exclusive double-gap diffractive pp scattering, pp -> p + H + p. It is based on the idea that hard and soft interactions are approximately independent (QCD factorization), and allows us to calculate the RGS probability in a model-independent way in terms of the gluon generalized parton distributions (GPDs) in the colliding protons and the pp elastic scattering amplitude. Here we focus on the transverse momentum dependence of the cross section. By measuring the ''diffraction pattern'', one can perform detailed tests of the interplay of hard and soft interactions, and even extract information about the gluon GPD in the proton from the data.
2006-04-20
The significance of local hard zones on the outside of pipeline girth welds: Further studies
Energy Technology Data Exchange (ETDEWEB)
The NACE MR-01-75 standard imposes a restriction of 22HRC maximum for regions of a pipeline girth weld that are not in direct contact with H[sub 2]S containing environments. TWI have demonstrated in an earlier project for the Pipeline Research Committee (PRC) that it may be permissible to relax this maximum hardness requirement. Such a relaxation, which already exists in the BS4515: 1984 standard, offers potential benefits when applied to the capping pass and heat affected zone of a pipeline girth weld. This report presents additional data to supplement that obtained in a previous PRC project conducted at TWI. Further pipe materials with differing pipe wall thicknesses have been welded, exposed to an internal H[sub 2]S containing environment and examined for sulphide stress corrosion cracking.
1991-10-01
The effect of solutes on defect distributions and hardening in ion-irradiated model ferritic alloys
International Nuclear Information System (INIS)
A series of nine model ferritic alloys were ion irradiated at #propor to#300 C using 2.5 MeV He ions to a dose of 1.4 x 10"2"1 ion/m"2, which corresponds to #propor to#0.1 dpa at a depth of 2 #mu#m and #propor to#3.5 dpa at the peak damage region which occurs at about 4 #mu#m deep. The resultant changes in hardness as a function of depth were measured using a Nanoindenter "t"r"a"d"e"m"a"r"k. TEM was used to investigate the defect distributions. The effect of various solutes, Cu and N in particular, but Mn and Ti as well, on the change of hardness and the defect distribution due to the ion irradiation are discussed. (orig.).
British Library Electronic Table of Contents (United Kingdom)
The corrosion behavior of hard metals with VC and Cr3C2 grain growth inhibitors was investigated in alkaline solutions by electrochemical methods. The two inhibitors have opposite effects on the corrosion behavior: Cr3C2 significantly improves the corrosion behavior, whereas VC-containing alloys show a poor resistance. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and analytical transmission electron microscopy (TEM) analyses of the distributions of Cr and V in the composite material, as well as in the surface layers formed during corrosion were employed to clarify the influence of these elements on the corrosion behavior. The measurements showed that VC is precipitated mostly along the WC/binder interface after the liquid-phase sintering process, while Cr3C2 is almost homogene...
2011-01-01
Sensitization and radiation hardening of the photostimulable X-ray storage phosphor CsBr:Eu2+
British Library Electronic Table of Contents (United Kingdom)
The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...
2009-01-01
International Nuclear Information System (INIS)
Rossi X-ray Timing Explorer (RXTE) observations of the bright supernova remnant Cas A have revealed a hard power law component above 10 keV in addition to two thermal components inferred from ASCA measurements of the many line centroids from low-Z elements. The power law can be shown to be consistent with synchrotron emission from radio to hard x-rays by electrons of up to 4 x 10"1"3 eV. Measurement of the 1157 keV line by CGRO from "4"4Sc in the chain of decay of "4"4Ti predicts that the two "4"4Ti lines at 68 and 78 keV should appear at the CGRO intensity. RXTE has placed upper limits on such lines that are marginally consistent with the CGRO measurement. Implications of these results on sites for cosmic ray acceleration and nucleosynthesis are discussed.
1999-01-01
Plasma nitriding of Fe-18Cr-9Ni in the range of 723-823 K
Energy Technology Data Exchange (ETDEWEB)
To clarify the mechanism of plasma nitriding, the authors examined the optical microstructure, the hardness, the precipitation, and the concentration of dissolved nitrogen in Fe-18Cr-9Ni nitrided using plasma in the range of 723-823 K. Compared with ammonia-gas nitriding, the features of plasma nitriding are the formation of small chromium-nitride precipitates (CrN), the absence of an externally nitrided layer, the high concentration of dissolved nitrogen, and the high hardness (HV = 1,200). The diffusion coefficient of nitrogen in the present alloy was determined using the growth rate of the internally nitrided layer, based on calculations used in internal oxidation. Plasma- and gas-nitriding were also compared with respect to the growth rate of the nitrided layer.
1991-08-01
Plasma nitriding of AISI 304 steel
International Nuclear Information System (INIS)
In the present investigation, the properties of plasma nitrided AISI 304 steel were studied by changing the presence of nitrogen in the gas mixture. The plasma nitriding was performed at temperature -560 deg C, pressure -4 mbar and duration 24 hours. The nitrided samples were characterized by evaluating the phase composition, micro hardness, and diffusion layer thickness. The phase analysis indicates the mixed phases of CrN and Fe_3N, Fe_3N and Fe_4N which has the highest intensity. The results show the glow discharge plasma nitriding in presence of N_2 (80 vol. %) and H_2 (rest) produced higher hardness as well as higher case depth. (author)
2004-09-01
Partnership agreement signed for polymer-additive project
Energy Technology Data Exchange (ETDEWEB)
A polymer-based additive that permanently reduces hardness in wood electrical transmission poles treated with a chromated copper arsenate (CCA) preservative, has been developed by a team of IREQ researchers. A three-phase project is being funded by Hydro-Quebec to evaluate the additive's effect on full-size hydro poles subjected to actual climatic conditions. The evaluation project is designed to test the CCA and the additive's degree of retention by analyzing the hardness measurements against climbing tests, and the washing resistance of the chromium, copper and arsenate in the CCA/polymer-additive treatment. CCA-treated poles will be used for reference. Accelerated aging tests to characterize the polymer's resistance to UV rays will also be part of the validation program.
1999-12-31
Energy Technology Data Exchange (ETDEWEB)
With the aim of optimizing the nitriding process, experimental studies of the plasma nitriding of four selected steels were carried out, using a d.c. glow discharge. The process parameters were varied systematically. By means of transmission and scanning electron microscopy and X-ray diffraction, the microstructures, including the thicknesses of the compound zones and the diffusion zones of the nitrided steels, were obtained. Using cross-sectional samples and a micro-Vickers indenter, hardness depth profiles were also obtained. From the time and temperature dependences of the hardness profiles, effective diffusion constants and corresponding activation enthalpies were obtained. Furthermore, in an attempt to shed some light on the atomistic nitriding mechanisms, the glow discharges were studied by measuring energy spectra of the energetic ions hitting the cathode (the steel test specimens). It was shown that an increase of the mean energy of the ...
2000-02-01
Nanostructuring and hardening of LiF crystals irradiated with 3?15 MeV Au ions
British Library Electronic Table of Contents (United Kingdom)
Modifications of the structure and mechanical properties in LiF crystals irradiated with MeV-energy Au ions have been studied using nanoindentation, atomic force microscopy and optical spectroscopy. The nanostructuring of crystals under a high-fluence irradiation (above 1013 ions/cm2)?was?observed. Nanoindentation tests show a strong ion-induced increase of hardness (up?to 150?200%), which is related to the high volume concentration of complex color centers, defect aggregates, dislocation loops and grain boundaries acting as strong barriers for dislocations. From the?depth profiling of the hardness and energy loss it follows that both nuclear and electronic stopping mechanisms of MeV Au ions contribute to the creation of damage and hardening. Whereas the electronic stopping is dominating i...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Given the important role of parent-youth communication in adolescent well-being and quality of life, we sought to examine the relationship between specific communication variables and youth perceived quality of life in general and as a deaf or hard-of-hearing (DHH) individual. A convenience sample of 230 youth (mean age = 14.1, standard deviation = 2.2; 24% used sign only, 40% speech only, and 36% sign + speech) was surveyed on communication-related issues, generic and DHH-specific quality of life, and depression symptoms. Higher youth perception of their ability to understand parents' communication was significantly correlated with perceived quality of life as well as lower reported depressive symptoms and lower perceived stigma. Youth who use speech as their single mode of communication ...
2011-01-01
Mechanical properties of SiAlON glass surface after swift heavy-ion bombardment
International Nuclear Information System (INIS)
A Y-Mg-Si-Al-O-N glass was submitted to swift heavy-ion bombardment at GANIL (Caen, France) and the influence of irradiation on the mechanical properties was studied. The mechanical properties of the glass were characterized both before and after irradiation. Changes in hardness, elastic modulus and fracture toughness of the near-surface irradiated layer were determined using indentation techniques. SRIM calculations allowed to estimate the ions penetration range and the energy deposition relative to electronic and nuclear interactions, which can be correlated to the experimental damaged depth. Meyer's hardness and Young's modulus decrease by about 30 %, while fracture toughness is increased by more than 40 %. (authors)
Magnetic properties of Fe-Co-Mo-Cu-B nanocrystalline ribbons with stressing surfaces
British Library Electronic Table of Contents (United Kingdom)
Magnetic properties of Fe-Co-Mo-Cu-B alloy system with Co up to 26at.% were investigated. After proper thermal treatment, the nanocrystalline grain remains tiny, the density hardly increases, but the room-temperature saturation attains 1.5T mainly due to a high enough Curie temperature. The generally observed slant hysteresis loops point to ribbon surfaces, which stress the ribbon interior and induce a specific magnetoelastic contribution to hard-ribbon-axis magnetic anisotropy even after vacuum annealing. The effect does not come from cobalt but rather from the lack of silicon. Partial removal of the surfaces resulted in a decrease of the loop tilt.
2011-01-01
Hydrogen in titanium alloy with 16 at% Mo
International Nuclear Information System (INIS)
The effect of various hydrogen concentrations on the crystal lattice period and the hardness of titanium alloy was examined, the alloy containing about 16 at.% Mo (27.5 wt. % Mo) and having #beta# structure. The peculiar features of the mechanism of plastic deformation of the alloy were studied after adding hydrogen to it. A dependence of the crystal lattice period on the concentration of hydrogen was obtained for TixMoxH_2 alloy. It has been established that the hardness of the Ti-Mo alloy does not change when hydrogen is added to it. The presence of hydrogen introduces changes into the mechanism of deformation of #beta#-titanium alloy. The configuration of the inverse pole figures after rolling proves that the transverse slip process in an alloy with hydrogen is hampered, and that the coplanar slip process is developing in it.
Experimental and Numerical Study of Shot Peened Thin Hard-Coated Components
British Library Electronic Table of Contents (United Kingdom)
A test bench was designed and assembled to carry out impact tests on samples and components. The system allows simple and rapid adjustment of the test parameters, such as the shot size and air pressure, with good repeatability of the results. Tests on steel and light alloys were carried out under both as-produced condition and on thin hard-coated samples. Significant reductions in dimple dimensions were seen after coating. FE models simulating the experiments overestimated the dimple depths, although the parameter trend was satisfactorily captured. The residual stresses from coating and shot peening determined numerically are believed to have been proven effective against fatigue.
2011-01-01
Estimation of dietary intake of ochratoxin A from liquorice confectionery
British Library Electronic Table of Contents (United Kingdom)
Ochratoxin A (OTA) was analyzed from 44 liquorice confectionery samples using immunoaffinity cleanup and liquid chromatography coupled with fluorescence detection. The presence of OTA was confirmed by methyl-ester derivatization. Liquorice confectionery samples were purchased from different retail outlets and supermarkets in Spain during 2007-2008, 16 of hard candies and 28 of soft candies. The incidence of OTA varied between 75% and 39% and mean ranged from 2.96 to 0.34mg/kg for hard and soft candies, respectively. Assuming a total mean value of 1.29mgOTA/kg sweet and a consumption of about 1.2g liquorice sweets per day, an OTA weekly uptake of 11ng was obtained, or, based on a total body weight of 30kg for a child consuming these sweets regularly, a weekly intake of 0.37ng/kg body weight...
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
Effect of oil palm empty fruit bunch (OPEFB) fiber and poly(methyl acrylate) grafted OPEFB on several mechanical properties of poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blends using HAKEE Rheomixer at the rotor speed of 50 rpm, mixing temperature 150degreeC, and mixing period of 20 min. The fiber loadings were varied from 0 to 30% and the effect of fiber content in the composites on their ultimate tensile strength (UTS), Youngs modulus, elongation at break, flexural modulus, hardness, and impact strength were determined. An increasing trend was observed in the Youngs modulus, flexural modulus, and hardness with the addition of grafted and ungrafted fiber to the PVC/ENR blends. However the i...
2008-01-01
Effects of various gas mixtures on plasma nitriding behavior of AISI 5140 steel
International Nuclear Information System (INIS)
AISI 5140 steel was plasma nitrided at various gas mixtures of nitrogen, hydrogen, and argon to investigate the actions of hydrogen and argon on plasma nitriding. The structural and mechanical properties of ion-nitrided AISI 5140 steel have been assessed by evaluating composition of phases, surface hardness, compound layer thickness, and case depth by using X-ray diffraction (XRD), microhardness tests, and scanning electron microscopy (SEM). It was found that the growth of compound layer can be controlled and the diffusion improved when the gas mixture includes H_2 gas. Additionally, it was determined that the amount of Ar in dual gas mixture must be at 20% minimum to obtain distinctive surface hardness and compound layer thickness.
2002-10-01
Duplex surface treatment of AISI 1045 steel via plasma nitriding of chromized layer
British Library Electronic Table of Contents (United Kingdom)
In this work AISI 1045 steel were duplex treated via plasma nitriding of chromized layer. Samples were pack chromized by using a powder mixture consisting of ferrochromium, ammonium chloride and alumina at 1273K for 5h. The samples were then plasma-nitrided for 5h at 803K and 823K, in a gas mixture of 75%N2+25%H2. The treated specimens were characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD) analysis and Vickers micro-hardness test. The thickness of chromized layer before nitriding was about 8mm and it was increased after plasma nitriding. According to XRD analysis, the chromized layer was composed of chromium and iron carbides. Plasma nitriding of chromized layer resulted in the formation of chromium and iron nitrides and carbides. The hardness of the duplex layer...
2011-01-01
International Nuclear Information System (INIS)
The energy, angular momentum, and distance (measured from the center of mass of the nucleus) distributions of the effective number of 6q-fluctons are investigated and it is shown that many of the characteristics of these distributions are universal, i.e., independent of the flucton size. ''Saturation'' of the flucton density in nuclei with mass A approx > 80 and certain other features that determine the difference between the behaviors of the effective numbers of fluctons and deuterons are reported. This is used to explain the well known underestimation (by a factor of 1.5--6) of the cross section for the hard inclusive (p, p'd) process on nuclei calculated in the quasielastic formalism. See S. G. Kadmenskii and V. I. Furman, Alpha decay and elated nuclear reactions (in Russian), Energoatomizdat, Moscow, 1985.
Energy Technology Data Exchange (ETDEWEB)
The energy, angular momentum, and distance (measured from the center of mass of the nucleus) distributions of the effective number of 6/ital q/-fluctons are investigated and it is shown that many of the characteristics of these distributions are universal, i.e., independent of the flucton size. ''Saturation'' of the flucton density in nuclei with mass /ital A//approx gt/80 and certain other features that determine the difference between the behaviors of the effective numbers of fluctons and deuterons are reported. This is used to explain the well known underestimation (by a factor of 1.5--6) of the cross section for the hard inclusive (/ital p/, /ital p/'/ital d/) process on nuclei calculated in the quasielastic formalism. See S. G. Kadmenskii and V. I. Furman, /ital Alpha/ /ital decay/ /ital and elated/ /ital nuclear/ /reactions/ (in Russian), Energoatomizdat, Moscow, 1985.
1989-01-01
Damage mechanisms around hardness indentations in Ti{sub 3}SiC{sub 2}
Energy Technology Data Exchange (ETDEWEB)
Microstructural observations of damage around indentations in Ti{sub 3}SiC{sub 2} are presented. The Vickers hardness decreased with increasing load and asymptotically approached 4 GPa at the highest loads. No indentation cracks were observed even at loads as high as 300 N. Preliminary strength versus indentation plots indicate that, at least for the large-grained material ({approx}100 {micro}m) studied here, Ti{sub 3}SiC{sub 2} is a damage-tolerant material able to contain the extent of microdamage to a small area around the indent. The following multiple energy-absorbing mechanisms have been identified from scanning electron micrographs of areas in the vicinity of the indentation: diffuse microcracking, delamination, crack deflection, grain push-out, grain pull-out, and the buckling of individual grains.
1997-02-01
Conceptual design of a low-temperature radiation-hard tracker detector
Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.
2003-01-01
(Ti,Cr,Nb)CN coatings deposited on nitrided high-speed steel by cathodic arc method
British Library Electronic Table of Contents (United Kingdom)
The combined processes of plasma nitriding and cathodic arc deposition of (Ti,Cr,Nb)CN coatings were applied to HSS substrates. The nitrided layers, obtained in a mixture of H2 (70%) and N2 (30%) at two different temperatures (480^oC and 510^oC), were examined for the microhardness depth profiles. Characterization of the duplex coatings was performed by investigating elemental and phase composition, texture, hardness, friction and wear. XRD and XPS analyses revealed the formation of a mixture of a carbonitride fcc solid solution, in a dominant proportion, and metallic chromium. The film hardness was measured to be ~34GPa. The duplex (Ti,Cr,Nb)CN coatings exhibited superior tribological behavior as compared to both nitrided layers and non-duplex coatings.
2011-01-01
International Nuclear Information System (INIS)
Conventional plasma carburizing or nitriding for austenitic stainless steels results in a degradation of corrosion resistance. However, a low temperature plasma surface treatment can improve surface hardness without deteriorating the corrosion resistance. The 2-step low temperature plasma processes (the combined carburizing and post nitriding) offers the increase of both surface hardness and thickness of hardened layer and corrosion resistance than the individually processed low temperature nitriding and low temperature carburizing techniques. In the present paper, attempts have been made to investigate the influence of the introduction of Ar gas (0#approx#20%) in nitriding atmosphere during low temperature plasma nitriding at 370 .deg. C after low temperature plasma carburizing at 470 .deg. C. All treated specimens exhibited the increase of the surface hardness with increasing Ar level in the atmosphere and the surface ...
2008-03-01
Radiation hardening of optical fiber links by photobleaching with light of shorter wavelength
International Nuclear Information System (INIS)
The influence of additionally injected short-wavelength photobleaching light on the radiation hardness of Ge-doped graded index fibers working at 1,300 nm wavelength is investigated. Predictions are complicated by the fact that more efficient shortwave bleaching light experiences higher radiation-induced loss. Promising results are found for low fiber temperatures (approx-lt -50 C) and bleaching light of about 835 nm wavelength.
1995-09-18
Radiation hardening of a high voltage IC technology (BCDMOS)
International Nuclear Information System (INIS)
A program was undertaken to radiation harden an existing power integrated circuit technology (BCDMOS) to total dose, gamma dot, SEU, and neutrons. Efforts have centered around hardening and optimizing our CMOS, DMOS, and NPN devices. Initial results indicate a substantial improvement in hardness over our existing commercial technology.
1990-07-16
Quantitative phase imaging using hard x-rays
International Nuclear Information System (INIS)
The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.
2009-02-01
Energy Technology Data Exchange (ETDEWEB)
Olive oil mill wastewaters (OMW) cause disposal problems because they contain powerful pollutants such as phenolic compounds. Complete biodegradation or removal of these compounds is hardly achieved by a single treatment method. In this work, we investigated 2 integrated technologies for the treatment of the recalcitrant contaminants of OMW, allowing water recovery and reuse for agricultural purposes. (Author)
2009-07-01
International Nuclear Information System (INIS)
In order to investigate interactions of (Ti,W)(C,N) and (Ti,Mo)(C,N) with binder metals solid/solid diffusion couples were annealed. These two-dimensional arrangements provide good access to phase reactions occurring upon sintering already in the solid state. It was found in (Ti,W)(C,N)/Co- and (Ti,W)(C,N)/Ni-based couples that the reaction zone is thinner in contact with Co than with Ni. It was also observed that the reaction rate with both Co and Ni is lower if nitrogen is added to the hard phases. Beside a thickness variation of the diffusion zones a change in the microstructure was found. At the interface of nitrogen-free hard phases in contact with Co elongated microstructural constituents are formed with the main axis perpendicular to the interface, while at the interface of nitrogen-containing hard phases these elongated microstructural constituents were found in contact with Ni. Also phase reactions and the ...
2001-05-01
Organizational options for a future Romanian electricity market
International Nuclear Information System (INIS)
All over the world the implementation of energy efficient and clean technologies can be hardly considered without opening the way to competition and the involvement of private investment. If such terms are valid for reach countries there are even more adequate for economies in transition like Romania's, which inherited and obsolete productive equipment, can mobilize insufficient resources for development-modernization and exhibits a quasi-unanimous option of adhering at European Union. (author). 3 tabs., 11 refs.
1996-09-01
Energy Technology Data Exchange (ETDEWEB)
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.
2006-06-12
Energy Technology Data Exchange (ETDEWEB)
In the year 2008, the high pressure partial turbine and two low pressure partial turbines in the hard coal power station Bergkamen (Federal Republic of Germany) were modernized. A three-dimensional blade design and innovative seals were used. This resulted into a distinct increase in efficiency among other things.
2010-07-01
Micro borehole drilling platform
Energy Technology Data Exchange (ETDEWEB)
This study by CTES, L.C. meets two main objectives. First, evaluate the feasibility of using coiled tubing (CT) to drill 1.0 inches-2.5 inches diameter directional holes in hard rocks. Second, develop a conceptual design for a micro borehole drilling platform (MBDP) meeting specific size, weight, and performance requirements. The Statement of Work (SOW) in Appendix A contains detailed specifications for the feasibility study and conceptual design.
1996-10-01
Industrial ecology at Lawrence Livermore National Laboratory summary statement
Energy Technology Data Exchange (ETDEWEB)
This statement summarizes Lawrence Livermore National Laboratory`s committment to making important scientific, technological, and business contributions to global sustainability. The quest has many aspects, some socio-political or economic and some technological, and some in which the soft and hard sciences become indistinguishable, as in visionary national strategies, like Holland`s, and futuristic regional and city development plans, like those of Kagoshima and Chattanooga.
1996-05-21
Improvement in loosening equipment
Energy Technology Data Exchange (ETDEWEB)
The loosening equipment consists of a base machine and four-link suspension mechanism which is a cross frame with loosening gear connected to the base machine by universal hinges. In order to improve the reliability of the machine, the drive of transverse shifting in the cross frame is made of symmetrically arranged, shock-absorbing, hydraulic cylinders which are connected by additional universal hinges to the base machine and the lower pull rods. The design of the loosening machine guarantees its reliable operation on soil with significant quantity of hard inclusions.
1982-01-01
Improved control of fuel crushing in coal-fired power stations
Energy Technology Data Exchange (ETDEWEB)
With the frequent load changes to which a hard coal power station is subjected in the middle and peak load range, great demands are linked with the transient behaviour of the steam generator. Due to the serial connection of the crusher and boiler, the strongly delaying transient behaviour of the crusher compounds entirely with the transient behaviour of the steam generator. Therefore, a suggestion is to be made here as to the improvement of the dynamics of the crusher.
1988-01-01
Effect of rapid thermal annealing on radiation hardening of MOS devices
International Nuclear Information System (INIS)
The influence of RTA (Rapid Thermal Anneal) treatment on MOS radiation hardness is demonstrated and compared with classical furnace treatment. In the case of the RTA, the oxide trapped charge is found to depend on: (i) the anneal temperature as expected, data are in good agreement with a recently developed model of oxygen out-diffusion; (ii) the location across the wafer with a radial dependence, results could be related to stress induced by thermal gradient.
1995-07-17
East-Asia nuclear/fossil power plant competitiveness
Energy Technology Data Exchange (ETDEWEB)
The competitiveness of a new nuclear plant vs. a new oil or gas fired combined cycle plant or a coal fired plant in East-Asia, is reviewed in the paper. Both the nuclear and the fossil fired plants are evaluated as either utility financed or independent power producer (IPP) financed. Two types of advanced light water reactors (ALWRs) are considered in this paper, namely evolutionary ALWRs (1200 MWe size) and passive ALWRs (600 MWe class). A range of capital and total generation costs for each plant type is reported here. The comparison centers on three elements of overall competitiveness: generation costs, hard currency requirements, and employment requirements. Each of these aspects is considered perspective. Year-by-Year generation cost history over the plant lifetime is shown in some cases. It is found here that a utility financed evolutionary and passive ALWRs are broadly competitive with an IPP financed gas fired combined cycle plant and are more economic than ...
1996-12-31
Energy Technology Data Exchange (ETDEWEB)
Geological, geophysical, and engineering-geological research conducted at the 'Yeniseisky' site obtained data on climatic, geomorphologic, geological conditions, structure and properties of composing rock, and conditions of underground water recharge and discharge. These results provide sufficient information to make an estimate of the suitability of locating a radioactive waste (R W) underground isolation facility at the Nizhnekansky granitoid massif
2002-12-27
Clinoptilolite filter for the removal of tritiated water vapour
International Nuclear Information System (INIS)
The removal of tritiated water vapour was tested by use of a small burning apparatus and a clinoptilolite filter. It was found that decontamination factor of about 10"4 could be obtained by a clinoptilolite filter. The adsorption of HTO in the clinoptilolite is caused by the diffusion, so it is necessary that filtration velocity is maintained below 0.01 m/sec. Decontamination factor was not influence by the moisture content of a clinoptilolite and tritiated water vapour once adsorbed on a filter was hardly removed. (auth.).
Characterization of structure and mechanical properties of MoSi{sub 2}-SiC nanolayer composites
Energy Technology Data Exchange (ETDEWEB)
A systematic study of structure-mechanical properties relation is reported for MoSi{sub 2}-SiC nanolayer composites. Alternating layers of MoSi{sub 2} and SiC were synthesized by DC magnetron and rf-diode sputtering, respectively. Cross-sectional transmission electron microscopy was used to examine three distinct reactions in the specimens when exposed to different annealing conditions: Crystallization and phase transformation of MoSi{sub 2}, crystallization of SiC, and spheroidization of the layer structures. Nanoindentation was employed to characterize the mechanical response as a function of structural changes. As-sputtered material exhibits amorphous structures in both types of layers and has a hardness of 11 GPa and a modulus of 217GPa. Subsequent heat treatment induces crystallization of MoSi{sub 2} to form the C40 structure at 500C and SiC to form the a structure at 700C. The crystallization process is directly responsible for hardness ...
1993-12-31
Biological network analysis and comparison: mining new biological knowledge
British Library Electronic Table of Contents (United Kingdom)
The mechanisms underlying life machinery are still not completely understood. Something is known, something is ?probably? known, other things are still unknown. Scientists all over the world are working very hard to clarify the processes regulating the cell life cycle and bioinformaticians try to support them by developing specialized automated tools. Within the plethora of applications devoted to the study of life mechanisms, tools for the analysis and comparison of biological networks are catching the attention of many researchers. It is interesting to investigate why.
2011-01-01
Autologous Platelet-Rich Plasma Mixed with Purified Fat Graft in Aesthetic Plastic Surgery
British Library Electronic Table of Contents (United Kingdom)
Platelet-rich plasma (PRP) is a platelet concentrate that has widely been used to accelerate the healing of soft and hard tissues. The preparation of PRP has been described by several authors. Preparation protocols vary from system to system, depending on the concentration of different integrating proteins. The objective of this article is to describe the principal use of PRP mixed with fat grafts in aesthetic plastic surgery.
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.
1994-06-01
Energy Technology Data Exchange (ETDEWEB)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations
1983-01-01
International Nuclear Information System (INIS)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.
7871-01-01
Tritium in surface waters, tap water and in precipitation in Poland during the 1994-1999 period
International Nuclear Information System (INIS)
Concentrations of tritium in environmental waters (precipitation, rivers, lakes, tap water) have been determined using electrolytic enrichment and liquid scintillation counting. In waters of big rivers (the Vistula and the Odra rivers), lakes and tap water the annual average concentrations were similar to each other being from 1.4 to 1.9 Bq x dm"-"3. These concentrations were similar to those in the precipitation in which they ranged from 1.7 to 2.2 Bq x dm"-"3. The lowest tritium concentrations were found in waters of the Seashore Region rivers (average for 1994-1999 was 1.1 Bq x dm"-"3). The tritium concentrations in surface waters and in precipitation are still higher than that of natural level. The data obtained show that tritium concentration in the water of rivers might depend on the size of drainage area. The observed seasonal variations of tritium concentration in the precipitation collected in Warsaw and at the Mount Sniezka indicate the stratospheric ...
2001-01-01
The Study of Phosphors Efficiency and Homogeneity using a Nuclear Microprobe
Energy Technology Data Exchange (ETDEWEB)
Ion Beam Induced Luminescence (IBIL) and Ion Beam Induced Charge Collection (IBICC) have been applied in the study of the luminescence emission efficiency and investigation of the homogeneity of the luminescence emission in phosphors. The IBIL imaging was performed by using sharply focused ion beams or broad/partially-focused ion beams. The luminescence emission homogeneity in samples was examined to reveal possible distributed crystal-defects that may lead to the inhomogeneity of the luminescence emission in samples.The purpose of the study is to search for suitable luminescent thin films that have high homogeneity of luminescence emission, large IBIL efficiency under heavy ion excitation, and can be placed as a thin layer on the top of microelectronic devices to be analyzed with Ion Photon Emission Microscopy (IPEM). The emission yield was found to be low for organic materials, due to saturation of the light output dependence on the energy deposition of heavy ions. The emission yield ...
2000-12-08
The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger ...
2009-01-01
We study the sensitivity to neutrino masses of a Galactic supernova neutrino signal as could be measured with the detectors presently in operation and with future large volume water \\v{C}erencov and scintillator detectors. The analysis uses the full statistics of neutrino events. The method proposed uses the principles of Bayesian inference reasoning and has shown a remarkably independence of astrophysical assumptions. We show that, after accounting for the uncertainties in the detailed astrophysical description of the neutrino signal and taking into account the effects of neutrino oscillations in the supernova mantle, detectors presently in operation can have enough sensitivity to reveal a neutrino mass (or to set upper limits) at the level of 1 eV. This is sensibly better than present results from tritium $\\beta$-decay experiments, competitive with the most conservative limits from neutrinoless double $\\beta$-decay and less precise but remarkably less ...
2005-01-01
Studies on the interaction of lidocaine with plasma proteins
Energy Technology Data Exchange (ETDEWEB)
This study sought to quantitate lidocaine's interaction with alpha-1-acid glycoprotein (AAG), human serum albumin (HSA), and AAG in the presence of HSA, and to determine the extent of displacement of lidocaine from its binding site(s) by selected cardiovascular drugs (dipyridamole, disopyramide and quinidine). Since the limited experimental work reported in this area has involved the use of a single lidocaine concentration, this study involved the evaluation of a range of lidocaine concentrations. Lidocaine interaction with plasma proteins (AAG and HSA) was studied at 37/sup 0/C using an isothermal equilibrium dialysis system and /sup 14/C-lidocaine HCl. A dialysis membrane (M.W. cutoff 12,000 to 14,000) separated the two chambers of each dialysis cell. The extent of /sup 14/C-lidocaine dialysis was studied with respect to both drug and protein concentrations. Aliquots of each chamber of each of the cells were subjected to liquid scintillation counting ...
1985-01-01
International Nuclear Information System (INIS)
The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment determination. Compared to conventional gamma spectrometry, the method offers additional ...
2011-06-01
Pulmonary retention of lead: an experimental study in man
Energy Technology Data Exchange (ETDEWEB)
This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of scintillation detectors and two leg counters. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 hr. When the retention data were corrected for blood-borne /sup 203/Pb, the biological halftimes for lung lead retention averaged 13.1 and 14.2 hr, respectively, and were not ...
1980-01-01
Photoluminescence of europium doped LiInO2 powder
British Library Electronic Table of Contents (United Kingdom)
Abstract Lithium-indium oxide is one of the candidate materials as solid-state scintillators for solar neutrinos due to an inverse --decay of 115In to 115Sn. On the other hand, when doped with rare-earth ions such as Eu3+ or Sm3+, it becomes a promising phosphor material. In this report we present a simple solid-state procedure for preparation of LiInO2:Eu3+ powders. X-ray diffraction confirmed prod-uct in tetragonal structural form (space group: I41/amd) and no impurity phases were detected. Then, high resolution photoluminescence emission measurements were performed at room and low temperatures to find 5D0 - 7FJ. Emission kinetics from 5D0 level exhibited pure single exponential behavior with lifetime of about 1.5 ms. Maximum energy splitting of 7F1 manifold is recorded as a function of ...
2011-01-01
Persistence of terbufos and its metabolites in soil and maize
International Nuclear Information System (INIS)
Degradation of "1"4C terbufos was studied under greenhouse conditions. A mixture of "1"4C labelled compound (2.48 x 10"4 Bq of O-ethyl-1- "1"4C) und unlabelled compound (0.09 g of the granule formulation Counter 10 G) was applied to pots containing 750 g of sandy loam clay Ultisol soil with 4.9% organic matter and a cation exchange capacity of 7.6. Two treatments were established, one where maize (cultivar Cristiani) was grown and the other without plants. The soil and plants were extracted at 0, 4, 8, 16, 32 and 64 days and analyzed by a liquid scintillation counter, gas chromatography-flame photometric detector (GC-FPD) and autoradiography. The total "1"4C compounds extracted on day 64 were 31 #+-# 5.6% of the radioactivity applied in the treatments with plants and 46.1 #+-# 1.1% without plants. From the autoradiography results it can be concluded that all times the compounds identified by this technique were terbufos, terbufos sulphoxide and terbufos sulphone. ...
1996-07-01
PET/MRI hybrid imaging: devices and initial results
International Nuclear Information System (INIS)
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI systems have shown ...
2008-06-01
Optical modules for the neutrino telescope KM3NeT
Energy Technology Data Exchange (ETDEWEB)
KM3NeT is a future deep-sea research infrastructure hosting a neutrino telescope with a volume of at least one cubic kilometer to be constructed in the Mediterranean Sea. The experiment aims to detect high-energy cosmic neutrinos using a 3D array of optical modules to collect the Cherenkov light induced by charged particles in the water. Upward going muons and showers produced in neutrino interactions with the surrounding matter will allow the search and study of possible sources of extra-terrestrial neutrinos. The design of optical modules makes an important impact on the performance and cost of the KM3NeT project. Several different optical module configurations are under consideration; based on glass pressure spheres containing: a large (10 in.) hemispherical photomultiplier tube (with a multi-anode version as an option); 25-31 3 in. photomultiplier tubes, or a crystal scintillator-based hybrid device (X-HPD). The features and advantages of each optical module ...
2010-11-01
Optical Turbulence Measurements and Models for Mount John University Observatory
Site measurements were collected at Mount John University Observatory in 2005 and 2007 using a purpose-built scintillation detection and ranging system. $C_n^2(h)$ profiling indicates a weak layer located at 12 - 14 km above sea level and strong low altitude turbulence extending up to 5 km. During calm weather conditions, an additional layer was detected at 6 - 8 km above sea level. $V(h)$ profiling suggests that tropopause layer velocities are nominally 12 - 30 m/s, and near-ground velocities range between 2 -- 20 m/s, dependent on weather. Little seasonal variation was detected in either $C_n^2(h)$ and $V(h)$ profiles. The average coherence length, $r_0$, was found to be $7 \\pm 1$ cm for the full profile at a wavelength of 589 nm. The average isoplanatic angle, $\\theta_0$, was $1.0 \\pm 0.1$ arcsec. The mean turbulence altitude, $\\bar{h_0}$, was found to be $2.0\\pm0.7$ km above sea level. No average in the Greenwood frequency, $f_G$, could be established due ...
2010-01-01
On-line video image processing system for real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 distinct colors on a RGB ...
1983-09-15
The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The method can be used in-situ, the ...
2004-01-01
Neutron capture therapy beam on the LVR-15 reactor
Energy Technology Data Exchange (ETDEWEB)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si[sup ...
1992-01-01
Neutron capture therapy beam on the LVR-15 reactor
International Nuclear Information System (INIS)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal neutrons in the human head phantom was mapped with a small semiconductor detector (Si"6Li). ...
1991-10-01
Natural radionuclides in drinking water in Argentina
International Nuclear Information System (INIS)
As part of the national survey to evaluate natural radioactivity in the environment, concentration levels of natural uranium and "2"2"6Ra have been analyzed in over 300 drinking water samples taken from different locations in Argentina. "2"2"6Ra was determined by "2"2"2Rn emanation and liquid scintillation counting, and natural uranium by a fluorimetric procedure. Values ranging from 0.03 to 24 #mu#g.l"-"1 of natural uranium and from 0.06 to 50 #mu#g.l"-"1, were measured on drinking water samples taken from tap water systems and private wells, respectively. Concentrations up to 15 mBq.l"-"1 and to 22 mBq.l"-"1 of "2"2"6Ra were found in drinking water samples taken from tap water systems and private wells, respectively. These values are compared with the reference values accepted for drinking water. Based on the water intake rate, the age distribution and the measured concentrations, an annual collective effective dose of 1.9 man Sv and an individual committed ...
2000-05-01
NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture
Energy Technology Data Exchange (ETDEWEB)
The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the theoretical background and ...
2010-01-01
Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium
Energy Technology Data Exchange (ETDEWEB)
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons and gamma rays are resolved in both time and energy to reveal ...
2004-03-09
Measuring the quark contribution to the proton spin through. nu. p yields. nu. p
Energy Technology Data Exchange (ETDEWEB)
The LSND (Liquid Scintillator Neutrino Detector) experiment will be performed at LAMPF in the next several years. The main goal of the experiment is to search for {nu}{sub {mu}}-{nu}{sub e} oscillations with high sensitivity; however, an increasingly important by-product of this search is to measure {nu}p {yields} {nu}p elastic scattering and determine the strange quark contribution, {Delta}s, to the spin of the proton. With the 800-MeV proton energy of LAMPF, neutrinos are produced from pion decay-in-flight with an average energy of about 150 MeV. This energy is sufficiently high so that the {nu}p {yields} {nu}p cross section is large and is sufficiently low so that the low Q{sup 2} approximation (Q{sup 2} {much lt} m{sub p}{sup 2}) is valid and the cross section can be expressed in a simple form dependent upon {Delta}s as the only unknown. LAMPF with its 1-mA proton intensity is, therefore, an ideal accelerator to perform this measurement. 12 refs., 7 figs., 2 ...
1991-01-01
Launch of the Space experiment PAMELA
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In self-trigger mode the ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
For the inventory of water tritium concentration in the Manche department, it is the complementarity that animated the work opened during year 2001. To answer to a commune sensitivity such water quality, particularly drinking water at tap, the A.C.R.O. laboratory brought its know how to make and its technical means in the area of tritium analysis and the general council brought its know how to make and its logistics means in matter of sanitary control. This collaboration has allowed to supply an indication on the tritium content of the distribution waters of thirty of the most important cities of the department. Then, it allowed to inform on the radiological situation (in relation with the tritium presence) of coast waters and principal rivers waters. More than 160 controls have been realised between the months of march 2001 and february 2002. Only the tritium under the shape of tritiated water has been measured. The measures have been made by liquid scintillation ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
The effect of atmospheric pressure on tracking resistance of organic insulating materials were investigated in the range of 500 to 1007 hPa. The tracking resistance for Polycarbonate (PC), Modified Polyphenylene Oxide (M-PPO) and Paper Base Phenolic Resin Laminate (PL) increase with the decrease in atmospheric pressure. The scintillating discharges on these samples surface lead to the ignition. The tracking failure on these results from the ignition on the surface. For Polybutylene Terephthalate (PBT) and Polyethylene Terephthalate (PET), the tracking resistance decrease with the decrease in atmospheric pressure. The discharges observed on the these surface are the glow-like. The discharge area spreads on the surface between the electrodes at the lower pressure. The failure on this group results from the carbonization by the discharges on the surface. However, the tracking resistance for Unsaturated Polyester Resins (UP) has no significant dependence on lower ...
1995-11-20
Energy Technology Data Exchange (ETDEWEB)
Water from small scale purification plants is a low cost alternative for consumers in comparison to the bottled commercial presentations. Because of its low cost per liter, the consumption of this product has increased in recent years, stimulating in turn the installation of purification systems for these small businesses. The purpose of this study was to estimate the efficiency of small scale purification systems located in the cities of Zacatecas and Guadalupe, Zacatecas, to reduce the radioactive content of water. It was measured the total alpha and beta activity in water samples of entry and exit to process, through the liquid scintillation technique. In general it was observed that the process is more efficient in removing alpha that beta activity. The fraction of total alpha activity removed varied between 27 and 100%, while between 0 and 77% of the total beta activity was removed by the analyzed plants. In all cases, the total radioactivity level was lower ...
2009-10-15
Detection of Second-Layer Corrosion in Aging Aircraft Fuselage
International Nuclear Information System (INIS)
A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple reconstruction model is also ...
2006-12-01
Detection of Second-Layer Corrosion in Aging Aircraft
International Nuclear Information System (INIS)
The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented for quantitative ...
2009-12-01
International Nuclear Information System (INIS)
In humid zones and marine environments the bio indicator contaminants by trace elements are well established. However, in arid zones it is more difficult to find these tools because there is less biodiversity. The objective of this paper was to analyze the behavior of the Baccharis salicifolia plant in areas with high uranium concentration in arid zones, to determine the characteristics of tolerance and possible use as a bio monitor for the presence of such contaminants. For this project a uraniferous zone was selected in San Marcos, located northwest of the City of Chihuahua. A total of 8 sampling points of the plant and soil were located here. Each sample was divided into the root and the stem and leaves to determine the specific activity of the uranium in both parts of the plant and its sediments. The determination of the specific activities of the total uranium in the samples was obtained by liquid scintillation with alpha-beta separation. The results indicate ...
2011-02-01
An on-line video image processing system for real-time neutron radiography
International Nuclear Information System (INIS)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 distinct colors on a RGB ...
1983-09-01
Energy Technology Data Exchange (ETDEWEB)
This project was supported through ERDA to demonstrate that the temporal distribution of tritium can be documented by the analysis of bound hydrogen in annual tree-ring samples. The project focuses on two sample locations at the Savannah River Site (SRS), a nuclear material production facility located in Aiken, SC. The SRS provided samples of cross-sections from a single tree that were to be pooled together for analysis. Annual tree-rings were identified in each cross-section sample and separated for the period 1954 to 1993. These annual samples were ground and chemically treated to separate the hollocellulose fraction of the wood, then subsequently combusted and the resulting water counting using low-level liquid scintillation counting equipment. Additionally, the ground annual tree-rings were gamma-counted to determine any temporal variation in radionuclide activity and analyzed with x-ray fluorescence to find any temporal variation in trace-element ...
1995-03-21
A superconducting solenoidal spectrometer for a balloon-borne experiment
Energy Technology Data Exchange (ETDEWEB)
The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger rate and large data ...
2000-03-21
Pre-Flight Development of the PoGOLite Pathfinder
International Nuclear Information System (INIS)
The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...
Delayed neutron energy spectra following fast fission of "2"3"8U
International Nuclear Information System (INIS)
Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with "6Li-loaded glass scintillators for neutron energies from 10 keV to 450 keV and Bicron BC 501 liquid ...
Energy Technology Data Exchange (ETDEWEB)
We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the {bar {nu}}{sub e}p {yields} ne{sup +} ...
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
By using defined compositions based on industrial wastes of the hard-coal mining and a further waste material (red mud), which is obtained during the extraction process of alumina (BAYER-Process), it is possible to produce expanded-clay granulate requiring suitable preparation, shaping and firing at temperatures of about 1150 C. Some of the investigated parameters and aspects of this manufacturing process will be presented in this paper. (orig.) [German] Aus definierten Mischungen industrieller Reststoffe des Steinkohlenbergbaus (Bergematerial) mit einem weiteren Abfallstoff (Rotschlamm), der bei der Aluminiumoxidgewinnung nach dem BAYER-Verfahren anfaellt, laesst sich nach geeigneter Aufbereitung und Formgebung durch Brennen bei ca. 1150 C Blaehton-Grunulat herstellen. Auf einen Teil der untersuchten Parameter und ermittelten Zusammenhaenge soll im folgenden naeher eingegangen werden. (orig.)
1999-07-01
The Diagnostic Method of Inner Parts of Welded Joints at Nuclear Power Plant
International Nuclear Information System (INIS)
There is no possibility to check any inner part at real welded joint at nuclear power station (NPS) during operation because any destructive test cannot be used. In practice there is checked surface of weld. There are used four methodical instructions for the check of real welds: 1. The visual inspection, 2. The measurement of hardness, 3. The chemical composition checking and 4. The microstructure replica analysis. It is necessary to know how these information of weld surface are in accordance with characteristics of inner parts of weld. If there is not any difference between surface weld microstructure and internal weld microstructure of experimental weld it is supposed to that there is not any difference in other measured properties of welds. If is changed structural characteristics of microstructure, it is changed also hardness, chemical analysis etc. It was observed that the microstructure of real welds is almost the same with simulated ...
2010-06-22
Surface modification of titanium by radio frequency plasma nitriding
Energy Technology Data Exchange (ETDEWEB)
Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti{sub 2}N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 {mu}m{sup 2}/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to the high concentration of active nitrogen species in the plasma atmosphere and the formed microcracks near ...
2006-02-21
Surface modification of titanium by radio frequency plasma nitriding
International Nuclear Information System (INIS)
Radio frequency (RF) plasma nitriding using different input plasma processing powers (250-600 W) improves the surface of titanium by forming hard phases of TiN, Ti_2N, and Ti (N) into the surface. The characteristics of the compound layer have been investigated by optical microscopy, microhardness measurements, and X-ray diffraction. The effect of plasma power on the sample temperature, electron temperature, and plasma density was studied using Langmuir double probe. The measured surface hardness value of the compound layer is 2190 HV 0.1 for treated sample at plasma power 500 W. The compound thickness continuously increases as the plasma power increases. The highest nitriding rate of 5.88 #mu#m"2/s was recorded when the input plasma power was adjusted at 550 W. This high nitriding rate of treated titanium samples is ascribed to the high concentration of active nitrogen species in the plasma atmosphere and the formed microcracks near to the ...
2006-02-21
Surface hardening utilizing high-density plasma nitriding on stainless steel alloys
Energy Technology Data Exchange (ETDEWEB)
By using a plasma nitriding procedure at the PUPR Mirror Cusp Plasma machine, surface hardness is increased in 302/304-type stainless steel samples by exposing them to high-ion-density plasma at high vacuum. This method successfully dopes the surface of the material with strengthening nitrogen ions, without the use of chemical procedures that sacrifice the resistance to corrosion of the given material. A 500 V negative bias is placed on the sample exposed to the nitrogen plasma, where high-energy ions are therefore attracted and immersed into the metallic matrix microns into the surface of the stainless steel. This potential maintains a constant surface temperature at approximately 800 deg. C. The plasma parameters including ion density and plasma temperature were diagnosed using single Langmuir probes. The stainless steel samples were then tested using scanning electron microscopy (SEM), and Vickers micro-hardness testing to determine the ...
2008-10-15
Surface hardening utilizing high-density plasma nitriding on stainless steel alloys
International Nuclear Information System (INIS)
By using a plasma nitriding procedure at the PUPR Mirror Cusp Plasma machine, surface hardness is increased in 302/304-type stainless steel samples by exposing them to high-ion-density plasma at high vacuum. This method successfully dopes the surface of the material with strengthening nitrogen ions, without the use of chemical procedures that sacrifice the resistance to corrosion of the given material. A 500 V negative bias is placed on the sample exposed to the nitrogen plasma, where high-energy ions are therefore attracted and immersed into the metallic matrix microns into the surface of the stainless steel. This potential maintains a constant surface temperature at approximately 800 deg. C. The plasma parameters including ion density and plasma temperature were diagnosed using single Langmuir probes. The stainless steel samples were then tested using scanning electron microscopy (SEM), and Vickers micro-hardness testing to determine the ...
2008-10-01
Simultaneous plasma nitriding and ageing treatments of precipitation hardenable plastic mould steel
Energy Technology Data Exchange (ETDEWEB)
Simultaneous nitriding and ageing heat treatments of precipitation hardenable tool steel was carried out inside a DC-pulsed plasma nitriding reactor. A single heat treatment cycle was done, as the plasma nitriding and age hardening processes occur approximately at the same ranges of temperatures and times. Specimens of Cr-Ni-Mo-Al age hardenable steel, in the solubilized and solubilized and aged conditions, were tested. Plasma nitriding and ageing, carried out at 500 deg. C for times ranging between 2 and 8 h, increased the surface hardness up to 1000 HV, producing case depths between 100 and 200 {mu}m. The core hardness of solubilized samples increased from 30 to 39 Rockwell C after the plasma nitriding treatment proving the possibility of nitriding and ageing at the same treatment cycle. The pre-aged samples did not show any overageing after the simultaneous plasma nitriding and ageing treatments. The corrosion resistance after plasma ...
2007-07-01
Simultaneous plasma nitriding and ageing treatments of precipitation hardenable plastic mould steel
International Nuclear Information System (INIS)
Simultaneous nitriding and ageing heat treatments of precipitation hardenable tool steel was carried out inside a DC-pulsed plasma nitriding reactor. A single heat treatment cycle was done, as the plasma nitriding and age hardening processes occur approximately at the same ranges of temperatures and times. Specimens of Cr-Ni-Mo-Al age hardenable steel, in the solubilized and solubilized and aged conditions, were tested. Plasma nitriding and ageing, carried out at 500 deg. C for times ranging between 2 and 8 h, increased the surface hardness up to 1000 HV, producing case depths between 100 and 200 #mu#m. The core hardness of solubilized samples increased from 30 to 39 Rockwell C after the plasma nitriding treatment proving the possibility of nitriding and ageing at the same treatment cycle. The pre-aged samples did not show any overageing after the simultaneous plasma nitriding and ageing treatments. The corrosion resistance after plasma ...
Energy Technology Data Exchange (ETDEWEB)
Microhardness decarburization profiles are often used in the industry to estimate the carbon distribution in steels. For quantitative evaluation, an analysis based on diffusion theory must be performed, the fundamentals and mathematical basics of which are presented. If the relationship between hardness and carbon content is known, microhardness-distance curves of steels can be analyzed in this way. For martensitic grades, for instance, a linearized expression holds in the concentration range from 0.15 to 0.6 m.% C. Microhardness depth profiles of higher carbon steels and other microstructures, however, are also evaluated in the literature. The applicability of quantitative diffusion modeling is discussed in detail. Through hardenable rolling bearing steel 100Cr6 (1.3505, SAE 52100) serves as model material: carbon concentration-distance curves are measured with high accuracy by secondary ion mass spectrometry (SIMS) and compared with microhardness decarburization ...
2007-07-01
Recent Progress in CdTe and CdZnTe Detectors
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these imaging detectors in future ...
2001-01-01
Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy
Energy Technology Data Exchange (ETDEWEB)
Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The performance of our newly developed inductively ...
1997-09-01
Radio-frequency plasma nitriding and nitrogen plasma immersion ion implantation of Ti-6Al-4V alloy
International Nuclear Information System (INIS)
Nitrogen ion implantation improves the wear resistance of Ti-6Al-4V alloys by forming a hard TiN superficial passivation layer. However, the thickness of the layer formed by traditional ion implantation is typically 100-200 nm and may not be adequate for many industrial applications. We propose to use radio-frequency (RF) plasma nitriding and nitrogen plasma immersion ion implantation (PIII) to increase the layer thickness. By using a newly designed inductively coupled RF plasma source and applying a series of negative high voltage pulses to the Ti-6Al-4V samples. RF plasma nitriding and nitrogen PIII can be achieved. Our process yields a substantially thicker modified layer exhibiting more superior wear resistance characteristics, as demonstrated by data from micro-hardness testing, pin-on-disc wear testing, scanning electron microscopy (SEM), as well as Auger electron spectroscopy (AES). The performance of our newly developed inductively ...
1996-09-15
Production of wood plastic properties using gamma radiation as a polimerization agent
International Nuclear Information System (INIS)
The properties of wood plastic composites (WPC) based on Pinus Radiata D. Don impregnated with methylmethacrylate and subsequently polymerized with gamma radiation were studied. Different systems of impregnation were utilized, in order to obtain partial and shell loads. The minimum irradiation dose uses was 16 kGy. The following tests were made to the material: static bending, compression strenght parallel to grain, hardness, sheer strength, toughness, water absorption, dimensional stability and flame propagation index. To evaluate the testing, the results of the samples were separated according final density in the ranges: R_1 = 429-483 kg/m3 (without treatment); R_2 = 500-650 kg/m3 and R3 = 651-850 kg/m3. In general, the best results were obtained for samples of high density. The most important results were achieved for dimensional stability, water absorption and hardness. (Author).
1984-01-01
Preparation of polyester/gypsum/composite using gamma radiation, and its radiation stability
Energy Technology Data Exchange (ETDEWEB)
Composites based on pure gypsum and polyester-styrene resin have been prepared using various doses of gamma radiation. Some physical properties of the prepared composites and the influence of irradiation dose on it have been studied as: compression strength, hardness, thermal decomposition temperature in nitrogen or oxygen, and the change in weight in aqueous solutions with different pH values. The glass transition temperature of the pure polymer and the composites increases with increasing the irradiation dose up to a plateau, and the glass transition temperature of the pure polymer is lower than that of the composites. The irradiation dose does not seem to affect the decomposition temperature of the pure polymer or the composites significantly and the decomposition temperature in presence of nitrogen is higher than that in presence of oxygen. Increasing the irradiation dose leads to an enhancement of the compression strength of the pure polymer and the prepared ...
2005-06-01
Preparation of high burnup fuel post-irradiation testing facility
Energy Technology Data Exchange (ETDEWEB)
In the fuel testing facilities of Japan Atomic Energy Research Institute, the post-irradiation test of practical fuel used in nuclear power stations was begun in December, 1979, and the soundness of practical fuel has been confirmed, and the valuable post-irradiation test data on the behavior of fuel have been acquired. Recently, the heightening of fuel burnup has been advanced, and also in fuel testing facilities, the development and preparation of the post-irradiation testing facility required for examining in detail high burnup fuel have been carried out. The course of the installation of the post-irradiation testing facility and the outline of the facility are reported. As the preparation of the post-irradiation testing facility for high burnup fuel, a hyperfine hardness tester that measures dynamic hardness, the measuring instrument for pellet thermal diffusion rate by laser flash method, the measuring instrument for pellet melting point ...
1996-05-01
British Library Electronic Table of Contents (United Kingdom)
Zirconium and particularly Zr-2.5wt%Nb (Zr2.5Nb) alloy are useful for engineering bearing applications because they can be oxidized in air to form a hard surface ceramic. Oxidized zirconium (OxZr) due to its abrasion resistant ceramic surface and biocompatible substrate alloy has been used as a bearing surface in total joint arthroplasty for several years. OxZr is characterized by hard zirconium oxide (oxide) formed on Zr2.5Nb using one step thermal oxidation carried out in air. Because the oxide is only at the surface, the bulk material behaves like a metal, with high toughness. The oxide, furthermore, exhibits high adhesion to the substrate because of an oxygen-rich diffusion hardened zone (DHZ) interposing between the oxide and the substrate. In this study, we demonstrate a two step pro...
2011-01-01
Clinical circumstances often demand flexibility in electrodiagnostic procedures. We present a clinical case that required alteration of our routine full-field electroretinography technique. The patient presented with reports of allergy to Xylocaine (lidocaine) and refused the use of any type of topical anesthetic drops. This conflicted with our routine ERG method that combines the use of the Henkes Lovac hard contact lens and the topical anesthetic Alcaine (proparacaine hydrochloride). We acquired a successful electroretinogram without topical anesthesia by using a "piggy-back" system involving the interposition of a soft hydrophilic contact lens between the cornea and the recording hard lens. The procedure yielded excellent ERG recordings and was well tolerated. This non-routine technique was also compared to our standard ERG technique using a normal volunteer. It appears that this proposed "piggy-back" technique is a useful alternative to ...
2007-11-06
Numerical analysis of erosion of the rotor labyrinth seal in a geothermal turbine
Energy Technology Data Exchange (ETDEWEB)
Excessive erosion of the labyrinth seal of a 100 MW geothermal turbine has been investigated. This study used computational fluid dynamics (CFD) and aims to identify one cause of erosion and a possible solution for substantially reducing it. The predictions were based upon a numerical calculation using a CFD model of the labyrinth seal with a water/steam flow containing hard solid particles and solved with a commercial CFD code: Fluent V5.0. The results confirmed the existence of flow conditions that play a major role in the rotor labyrinth seal erosion. Afterwards, the flow path was simulated with changes of rotor labyrinth seal geometry, which are indeed feasible of being implemented. The results confirmed that it is possible to reduce the erosion process by approximately 80% by incorporating a steam flow deflector in the fourth stage diaphragm, which changes the steam flow direction in the inlet zone to the rotor labyrinth seal channel, resulting in a reduction ...
2002-10-01
Nonthermal emission from the radio relic of the galaxy cluster A2256
We aim to obtain a consistent description of non-thermal emissions from Abell 2256 and to give a prediction for a gamma-ray emission from this galaxy cluster. Assuming that a radio relic illuminates a localization of an ongoing merger, and that both radio and non-thermal part of hard X-ray emission are due to electron component of cosmic rays filling the relic, we derived from radio and hard X-ray properties of the relic in A2256 the magnetic field strength and number densities for relativistic electrons and protons. Due to the interpretation of the radio relic as a structure formed just where a shock front is, we discuss a gamma-ray emission at the cluster periphery. The estimated strength of the magnetic field in the relic is equal to 0.05 \\muG, while the amplitude of the electron number density varies from 3 x 10^{-4} to 3 x 10^{-5} cm^{-3} (respectively for the relic thickness of 50 to 500 kpc). We got a substantial degree of ...
2011-01-01
Mechanical properties and tribological behavior of TiN-CrAlN and CrN-CrAlN multilayer coatings
Energy Technology Data Exchange (ETDEWEB)
There is an increasing number of applications for hard coatings in engineering where the properties of the single-layer coating are not sufficient. One way to solve this problem is to use a multilayer coating that combines the properties of several coating materials. In this study, TiN-CrAlN and CrN-CrAlN multilayer coatings were deposited on 100Cr6 and S6-5-2 (DIN) steel substrates, by means of unbalanced magnetron sputtering. For comparison, TiN, CrN and CrAlN single-layer coatings were also prepared. For all depositions the coating temperature was below 473 K. Indentation testing, hardness measurements and scratch tests were performed to characterize the mechanical properties. The correlation between the wear behavior in rolling contact and the mechanical properties of the multilayer coatings is reported. A ball crater preparation technique through scratch tests and wear tracks was used to observe the deformation and fracture behavior ...
1999-02-01
Energy Technology Data Exchange (ETDEWEB)
DC resistivity, dc magnetization, and specific heat of eight Sc{sub 5}Co{sub 4}Ge{sub 10}-type crystal-structure compounds R{sub 5}T{sub 4}Ge{sub 10} for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single-crystal magnetization, and specific-heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like {theta} reflects the strength of the crystal-field torque on the magnetic moments rather than the strength of antiferromagnetic exchange.
1988-01-01
Energy Technology Data Exchange (ETDEWEB)
DC resistivity, dc magnetization, and specific heat of eight Sc/sub 5/Co/sub 4/Ge/sub 10/-type crystal structure compounds R/sub 5/T/sub 4/Ge/sub 10/ for R = Dy, Ho, Er, Tm, and T = Rh and Ir are presented. The resistivity, single crystal magnetization, and specific heat results show that in all those compounds, the magnetic moments order antiferromagnetically in the c direction at low temperature. However, in the Er and Tm compounds, the magnetizations along x-y hard directions do not show any anomalies above 2.0 K. This suggests that the ordered Er and Tm ions, which have positive quadrupole coefficients ..cap alpha../sub j/, interact with a crystal field that has an electronic potential valley along the c axis. The fitting of the hard axis magnetizations to Curie-Weiss law suggests that the resulting antiferromagnetic-like theta reflects the strength of the crystal field torque on the magnetic moments rather than the strength of ...
1988-07-01
Limits on the Diffuse Radio and Hard X-ray Emission of Abell 2199
The Westerbork Northern Sky Survey (WENSS) and the NRAO/VLA Sky Survey (NVSS) were used to determine an upper limit to the diffuse radio flux from the nearby cluster Abell 2199. For the entire cluster, this limit is <3.25 Jy at 327 MHz from WENSS; for the inner 15' radius, the limit is <168 mJy at 1.4 GHz. These limits are used to constrain the cluster magnetic field by requiring that the radio flux be consistent with the hard X-ray (HXR) flux observed by BeppoSAX, assuming that the observed HXR excess is due to inverse Compton (IC) scattering of cosmic microwave background photons by relativistic electrons in the intracluster gas. We find that the magnetic field must be very weak (<0.073 uG) in order to avoid producing an observable radio halo. We also consider the possibility that the HXR excess is due to nonthermal bremsstrahlung (NTB) by a population of suprathermal electrons which are being accelerated to higher energies. We find that a NTB model ...
1999-01-01
The purpose of this project is to demonstrate targeted infill and extension drilling opportunities, better determinations of oil-in-place, methods for improved completion efficiency and the suitability of waterflooding in certain shallow-shelf carbonate reservoirs in the Williston Basin, Montana, North Dakota and South Dakota. Cores from five Red River wells in the Bowman-Harding study area have been examined and described in detail; contracts have been awarded for a 3-D survey in Bowman Co., ND and a 2D, multi-component survey in Richland Co.; extended-time pressure buildup data have been analyzed from two wells which are candidates for jetting-lance completion workovers; a 20-day injectivity test has been completed in the Red River (upper member); a jetting-lance completion program has commenced with one job completed and three more scheduled during April; and reservoir data from three key Red River fields in the Bowman-Harding study area has ...
1995-05-01
High variability in Vela X-1: giant flares and off states
We investigate the spectral and temporal behavior of the high mass X-ray binary Vela X-1 during a phase of high activity, with special focus on the observed giant flares and off states. INTEGRAL observed Vela X-1 in a long almost uninterrupted observation for two weeks in 2003 Nov/Dec. The data were analyzed with OSA 7.0 and FTOOLS 6.2. We derive the pulse period, light curves, spectra, hardness ratios, and hardness intensity diagrams, and study the eclipse. In addition to an already high activity level, Vela X-1 exhibited several intense flares, the brightest ones reaching a maximum intensity of more than 5 Crab in the 20-40 keV band and several off states where the source was no longer detected by INTEGRAL. We determine the pulse period to be 283.5320+/-0.0002 s, which is stable throughout the entire observation. Analyzing the eclipses provided an improvement in the ephemeris. Spectral analysis of the flares indicates that there appear to be ...
2008-01-01
Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors
This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through 3-dimensional depth sensing. Two types of detectors were available for evaluation. The ...
2004-01-01
International Nuclear Information System (INIS)
The 2-step low temperature plasma processes (the combined carburizing and post-nitriding) were carried out for improving both the surface hardness and corrosion resistance of AISI 316L stainless steel. The effects of processing time and temperature on the surface properties during nitriding step were investigated. The expanded austenite (#gamma#N)was formed on all of the treated surface. The thickness of #gamma#N was increased up to about 20 #mu#m and the thickness of entire hardened layer was determined to be about 40 #mu#m. The surface hardness reached up to 1,200 HV_0_._1 which is about 5 times higher than that of untreated sample (250 HV_0_._1). The thickness of #gamma#N and concentration of N on the surface were increased with increasing processing time and temperature. The corrosion resistance in 2-step low temperature plasma processed austenitic stainless steels was enhanced more than that in the untreated austenitic stainless steels due ...
2008-06-01
Effect of radiation dose on the properties of natural rubber nanocomposite
Energy Technology Data Exchange (ETDEWEB)
Effect of radiation dose and carbon nanotubes (CNT) on the mechanical properties of standard Malaysian rubber (SMR) was investigated in this study. SMR nanocomposites containing 1-7 phr CNT were prepared using the solvent casting method and the nanocomposites were radiated at doses of 50-200 kGy. The change in mechanical properties, especially, tensile strength (Ts), elongation at break (Eb), hardness and tensile modulus at 100% elongation (M{sub 100}) were studied as a function of radiation dose. The structure and morphology of reinforced natural rubber was investigated by FESEM, TEM and AFM in order to gain further evidence on the radiation-induced crosslinking. It was found that the Ts, M{sub 100} and the hardness of the SMR/CNT nanocomposites significantly increased with radiation dose; the elongation at break exhibited an increase up to 100 kGy, and a downward trend thereafter. Results on gel fraction further confirmed the crosslinking of ...
2010-12-15
British Library Electronic Table of Contents (United Kingdom)
The nanocomposite WC-Co powders were prepared through planetary ball milling method. Effects of grain growth inhibitor addition and the vacuum sintering parameters on the microstructure and properties of ultrafine WC-10Co cemented carbides were investigated using X-ray diffractometer, scanning electron microscope and mechanical property tester. The results show that VC and NbC additions can refine the WC grains, decrease the volume fraction of Co3W3C phase in ultrafine WC-10Co cemented carbides, and increase the hardness and fracture toughness of the base alloys. After sintering for 60 min at 1400 degreeC, the average grain size and hardness of ultrafine-grained WC-10Co-1VC cemented carbide are 470 nm and HRA 91.5, respectively. The fracture toughness of cemented carbide WC-10Co-1NbC alloy...
2009-01-01
Development and cytotoxicity evaluation of SiAlONs ceramics
International Nuclear Information System (INIS)
SiAlONs are ceramics with high potential as biomaterials due to their chemical stability, associated with suitable mechanical properties, such as high fracture toughness and fracture resistance. The objective of this work was to investigate the mechanical properties and the cytotoxicity of these ceramic materials. Three different compositions were prepared, using silicon nitride, aluminum nitride and a rare earth oxide mixture as starting powders, yielding Si_3N_4-SiAlON composites or pure SiAlON ceramics, after hot-pressing at 1750 deg. C, for 30 min. The sintered samples were characterized by X-ray diffraction analysis (XRD) and scanning electron microscopy (SEM). Furthermore, hardness and fracture toughness were determined using the Vicker's indentation method. The biological compatibility was evaluated by in vitro cytotoxicity tests. Ceramic with elevated hardness, ranging between 17 and 21 GPa, and high fracture toughness of 5 to 6 MPa ...
2007-01-01
Curing of natural rubber and epoxy adhesive
International Nuclear Information System (INIS)
Low molecular weight epoxy resin based on diglycidyl ether of bisphenol A was synthesized and mixed at constant percentages with natural rubber. The rubber epoxy system was cured with various types of curing agents such as ethylene diamine, maleic anhydride as well as the prepared resole phenol formaldehyde. A study of the photo-induced crosslinking of the prepared elastic adhesives and film samples was carried out by exposure to ultraviolet lamp (300 w) for 2 weeks at 20 deg. C. Samples containing ethylene diamine were cured at 25 + - 1 deg. C. for 24 h while samples containing maleic anhydride or resole phenol formaldehyde resins were thermally cured at 150-170 deg. C. for 10 min. Cured adhesive compositions were tested mechanically and physically and evaluated as wood adhesives. While hardness, chemical resistance as well as heat stability of the prepared cured film sample were investigated. The obtained data indicate that the highest epoxy resin content and the ...
2001-06-01
Creep ductility to failure of Alloy 800
International Nuclear Information System (INIS)
Research is in progress to obtain a satisfactory creep ductility for alloy 800 when used as heat exchanger material in sodium-cooled fast reactors (LMFBR). The creep test characteristics at present available show that a pronounced tendency to reduced elongation by creep failure may arise after prolonged testing in the 500-700 deg C temperature range. This phenomenon is now agreed to be primarily inherent to the conditions for Ni_3(Ti,Al) precipitation in the material and hence to the Ti and Al concentrations. By structural studies and hardness measurements on material subjected to creep tests and taken from a large number of castings, the relationship was established between the (Ti+Al) content and the structural hardness effect of Ni_3(Ti,Al) at 600 deg C. Below a certain Ti+Al concentration, no precipitation occurs and hence the creep ductility to failure can be improved considerably by limiting the allowed Ti+Al content in the material, ...
Wood-polymer composites obtained by gamma radiation
International Nuclear Information System (INIS)
It has been prepared composites materials by means of monomer penetration in pores of wood samples and later curing by means of gamma irradiation. The studied species were Hura crepitans L. (catahua), Aniba puchury-minor (C. Martinez) (mohena amarilla), and Calycophyllum spruceanum (Benth.) (capirona). These new materials exhibit smaller water absorption and better mechanical properties in comparison with native wood. The test tubes of catahua treated with the styrene-polyester mixture absorb only up to 10% humidity compared to the native species whereas its hardness is increased in a 100%. (author).
2006-01-01
International Nuclear Information System (INIS)
The tool materials durability problem, in particular shock and wear resistance, has allowed to formulate a set of requirements and also to stablish the dependence between physical properties and wear. However, for understanding the nature of the process, for example determining the tribological property of the cutting tool, it is necessary to consider the atom interactions in a crystal. A theoretical study of the physical properties of cutting tool materials (W-Ti-C) with varying concentration of titanium is presented. Total and partial local electronic density for each atom in such hard solutions were calculated. (nevyjel)
2001-05-01
Vibration suppressor for a manual perforator
Energy Technology Data Exchange (ETDEWEB)
A device is presented with handle containing hinges and work support arm, a flexible pin with supports and extra weights. The flexible pin is equipped with cantilevered sergments and weights. The bracket hinges on the handle are perpendicular to the axis of the flexible pin. To reduce handle vibration during drilling hard rock, the handle and brackets are joined to allow relative movement on the surface perpendicular to the hinges of the work support arm. The handle is joined to the work support arm parallel to the sides and the work support arm has holes to accomodate this. Elastic bushings are located between the lateral sides of the work support arm where it is joined to the handle.
1983-01-01
Uncertainties of radionuclide migration parameter values obtained from in-situ tracer experiments
International Nuclear Information System (INIS)
One of the key issues in safety assessment of high-level nuclear waste disposal is evaluating the effects of uncertainty inherent in radionuclide migration parameter values. In this paper, radionuclide transport parameter values and error variances (uncertainties) from in-situ tracer experiments, carried out in a single fracture at the Aespoe Hard Rock Laboratory (HRL) in Sweden, are identified by solving the inverse problem in a framework of the maximum likelihood theory. From the results, it is found that the parameter value uncertainty caused by a conceptual model of radionuclide migration is greater than that caused by a fluctuation in the observed breakthrough curve data. (author)
2005-10-03
Selective mining of bedded uranium deposits using high-pressure waterjet equipment
International Nuclear Information System (INIS)
High-pressure waterjet equipment is now technically and economically viable and commercially available for the following mining and construction applications: (1) drilling soft to medium-hard rock; (2) slotting, discing, chambering, and reaming in all types of rock. However, additional field experience is needed to prepare detailed economic evaluations. Extensive development of new explosives techniques and blasting methods will be required to take full advantage of the unique waterjet hole slotting, discing, and chambering capabilities.
1981-12-04
S-shaped magnetic macroparticle filter for cathodic arc deposition
Energy Technology Data Exchange (ETDEWEB)
A new magnetic macroparticle filter design consisting of two 90{sup o} filters forming an S-shape is described. Transport properties of this S-filter are investigated using Langmuir and deposition probes. It is shown that filter efficiency is product of the efficiencies of two 90{sup o} filters and the deposition rate is still acceptably high to perform thin film deposition. Films of amorphous hard carbon have been deposited using a 90{sup o} filter and the S-filter, and macroparticle content of the films are compared.
1996-04-01
Raising the durability of bucket wheel excavator teeth
Energy Technology Data Exchange (ETDEWEB)
Describes performance of excavator teeth manufactured with a new hard alloy. The alloy was developed by the Donetskii Politeknicheskii Institute. Its composition consists of a high-chromium steel with a larger amount of titanium than serial alloy, and a nitrogen additive. Trial tests of new alloy teeth were carried out in the Severnyi and Vershinskii coal surface mines. The teeth were attached to EhRP, EhPG and EhR bucket wheel excavators. Abrasive wear of 129 experimental teeth and 134 serial teeth was compared for different excavation conditions. Test results are tabulated; advantages of the new experimental teeth are listed. 3 refs.
1993-07-01
Radiation hardening of semiconductor parts
International Nuclear Information System (INIS)
This chapter is an overview of total-ionizing-dose and single-event hardening techniques and should be used as a guide to a range of research publications. It should be stressed that there is no clear and simple route to a radiation-tolerant silicon integrated circuit. What works for one fabrication process may not work for another, and there are many complex interactions within individual processes and designs. The authors have attempted to highlight the most important factors and those process changes which should bring improved hardness. The main point is that radiation-hardening as a procedure must be approached in a methodical fashion and with a good understanding of the response mechanisms involved.
Plasma source ion implantation of ammonia into electroplated chromium
Energy Technology Data Exchange (ETDEWEB)
Ammonia gas (NH{sub 3}) has been used as a nitrogen source for plasma source ion implantation processing of electroplated chromium. No evidence was found of increased hydrogen concentrations in the bulk material, implying that ammonia can be used without risking hydrogen embrittlement. The retained nitrogen dose of 2.1 {times} 10{sup 17} N-at/cm{sup 2} is sufficient to increase the surface hardness of electroplated Cr by 24% and decrease the wear rate by a factor of 4.
1995-02-01
Phase imaging using laser-produced X-ray sources
International Nuclear Information System (INIS)
A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging
2000-08-01
PBAR: A superconducting magnet spectrometer for cosmic ray antiproton studies
Energy Technology Data Exchange (ETDEWEB)
We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).
1990-09-15
Neutron irradiation effect on mechanical properties of metals after preliminary hardening
International Nuclear Information System (INIS)
Some results on mechanical property study of copper and titanium subjected to impact load and next to neutron irradiation are presented. It was shown that shock wave influence involves a substantial shape change of the stress-strain diagram and of respective mechanical characteristics. Yield- and ultimate strength were substantially increased, as well as hardness with a considerable drop of plasticity. Also a heat stability of copper and titanium specimens was studied after being treated with shock-waves and neutron radiation. Results are given of electron microscope study of titanium structure sfter explosion hardening, which caused decomposition of hydride segregations in titanium and increased dislocation density.
Micellar slug for oil recovery
Energy Technology Data Exchange (ETDEWEB)
A micellar slug for use in the recovery of oil is described, the slug containing a hydrocarbon, an aqueous medium, a surfactant, and a cosurfactant. The surfactant contains as an essential component an alpha-olefin sulfonate having 10 to 26 carbon atoms and containing 0.1% to 15% by weight by weight of a disulfonate. This micellar slug has an excellent salinity tolerance and hard-water resistance. Furthermore, the micellar slugs of the present invention are capable of forming micro-emulsions having a sufficiently low interfacial tension and, therefore, can improve oil recovery efficiency.
1985-08-27
Laser-assisted solar cell metallization processing. Quarterly report No. 6, March 1-June 30, 1985
Energy Technology Data Exchange (ETDEWEB)
A new lens was installed in the laser; the laser power was lowered and solar cells were made at different power levels. The concentration of the silver neodecanoate solution was changed to reduce linewidth. A cell fabrication run was completed using low-resistivity float-zone silicon. Experiments were initiated to investigate the use of titanium organometallic film, which not only forms an AR coating with a 400/sup 0/C hard bake, but may also help in bypassing front-metal evaporation because of high-reactivity of Ti with silicon. Progress in these areas is discussed.
1985-07-25
Ion-plasma nitriding of the alloyed steel using a low pressure arc plasma generator
International Nuclear Information System (INIS)
A study is made into microhardness and structure of coatings on various system steels (37G2S, 25Kh5M, R6M5), obtained by ion nitriding in a low pressure (10"-"1 Pa) arc discharge plasma. A comparison of properties is accomplished for steels nitrided in an arc gas discharge and in a furnace. It is stated that ion-plasma nitriding in an arc gas plasma generator is an efficient method of alloy steels hardening which allows changing the structure and increasing the hardness of a surface layer up to rather great depth
2006-12-01
Inhomogeneity of mechanical and fatigue properties of Al-Li alloys extrusions
Energy Technology Data Exchange (ETDEWEB)
Aluminium-lithium extrusions possess high inhomogeneity of properties across the cross section. Mechanical properties such as R{sub p0,2}, R{sub m} and hardness, but also fatigue properties, change their value in dependence with the cross section position where test specimens were taken. Positions, where extreme values of properties are measured, are characteristic for a given extrusion shape. The positions with different properties have different structure and texture. Properties and structure inhomogeneity is affected mainly by extrusion shape and heat treatment parameters. (orig.)
1996-12-01
Influence of laserglaze on microstructure and wear resistance of a cast Ni-base superalloy
Energy Technology Data Exchange (ETDEWEB)
The effect of high-energy-density laser surface melting on the morphology and properties of a cast Ni-based superalloy containing 33 wt percent Mo and 17 wt percent W is investigated experimentally. Significant improvements in the hardness and the wear resistance in both dry and acid environments are atttributed to the elimination of segregation in the laser-treated zone, where solid solubility increases, crystalline structure becomes finer, and the fine dendritic, cellular dendritic, cellular, and plane-front solidification structures are evenly distributed.
1984-04-18
In-situ TEM study of dislocation-twin boundaries interaction in nanotwinned Cu films
British Library Electronic Table of Contents (United Kingdom)
Epitaxial thin films of nanotwinned face-centered cubic metals such as Cu possess an unprecedented combination of high hardness and high electrical conductivity due to the unique structure of nanometer-spaced coherent twin boundaries. Recent studies of in-situ nanoindentation in a transmission electron microscope have provided new insights on the deformation behavior of nanotwins that are reviewed here. In particular, two unit processes are highlighted: first, stress-induced migration of ?3 {112} incoherent twin boundary that leads to de-twinning of nanotwins; second, twinning dislocation can be multiplied at ?3 {111} coherent twin boundary.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
By characterising the microstructure, quantitative image analysis allows to draw conclusions on the mechanical properties of materials. On fine microstructures with low contrast, e.g. of hardened steels, texture analysis has to be applied for quantification. Feeding texture parameters according to Haralick into a trained neural network, a correlation between the microstructure and the hardness of the steels C45 and 100Cr6 can be achieved. (orig.)
2001-08-01
High capacity anode materials for rechargeable sodium-ion batteries
Energy Technology Data Exchange (ETDEWEB)
Electrochemical techniques have been used to study the reversible insertion of sodium into hard-carbon host structures at room temperature. In this paper the authors compare these results with those for lithium insertion in the same materials and demonstrate the presence of similar alkali metal insertion mechanisms in both cases. Despite the gravimetric capacities being lower for sodium than lithium insertion, the authors achieved a reversible sodium capacity of 300 mAh/g, close to that for lithium insertion in graphitic carbon anode materials. Such materials may therefore be useful as anodes in rechargeable sodium-ion batteries.
2000-04-01
Heavy quark production in $\\gamma\\gamma$ collisions a theoretical reappraisal
Heavy quark production in $\\gamma\\gamma$ collisions is analyzed within the approach to hard collisions of photons recently proposed by the author. In this approach evaluating the cross section $\\sigma(\\gamma\\gamma\\to Q\\bar{Q})$ in the ``next-to-leading order of QCD'' requires the inclusion of direct photon contributions up to the order $\\alpha^2\\alpha_s^2$, whereas in the standard approach direct photon terms only up to the order $\\alpha^2\\alpha_s$ are taken into account. Phenomenological consequences of this difference are discussed.
2000-01-01
Grinding burn mechanism of directionally solidified superalloy
Energy Technology Data Exchange (ETDEWEB)
Directionally solidified nickel-based superalloy DZ4 is an important structural material. However, the grinding burn occurs in grinding processes has hindered the grinding efficiency and dimensional accuracy. This paper investigates the grinding mechanism of this new type of superalloy based on the systematical analyses of variable characteristics of the grinding force, grinding temperature, topography of ground surface, hardness distribution of surface layer, as well as morphology of surface layer from a metallographical point of view. The results will be beneficial to grinding the superalloy with high efficiency and high precision. (orig.)
2001-07-01
Friction stir welding of dissimilar formed Mg alloys (AZ31/AZ91)
Energy Technology Data Exchange (ETDEWEB)
Friction stir welding of dissimilar formed Mg alloys(AZ31/AZ91) was successfully carried out at the limited welding conditions. In a sound joint, SZ was mainly consisted of AZ31 Mg alloy which was located the retreating side. Dynamic recrystallization and grain growth occurred and {beta} intermetallic compounds of AZ 91 Mg alloy was not observed in SZ. BM had a higher hardness than that of the weld zone. The fracture location was not weld zone but BM of the AZ91 Mg alloy in tensile test. (orig.)
2005-07-01
Failure analysis on a ruptured petrochemical pipe
Energy Technology Data Exchange (ETDEWEB)
The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)
2010-08-15
Estimation of X-rays dose in the crystals of final thickness
International Nuclear Information System (INIS)
A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.
Energy Technology Data Exchange (ETDEWEB)
Emulsion explosives were discovered by Richard S Egley in 1961, but remained little known prior to rapid commercial development in the late 1970s. Their introduction has a significance that may in future be compared with the formulation of dynamite by Nobel in 1867 and the development of ammonium nitrate explosives in the mid 1950s. For the mining engineer emulsion explosives provide advantages of being inherently waterproof and having high strength with a high and stable velocity of detonation giving good fragmentation in hard rock. This is available at moderate cost, from an explosive that typically does not contain any self explosive ingredients and with fume properties that offer considerable advantages over other explosives. 2 figs., 1 tab.
1989-01-01
International Nuclear Information System (INIS)
Nanoindentation was performed on a Mo-alloy single crystal to investigate effects of focused ion beam (FIB) milling on mechanical behavior. On a non-FIB-milled surface, pop-ins were observed on all load-displacement curves corresponding to a transition from elastic to plastic deformation. Similar pop-ins were not detected on surfaces subjected to FIB milling. This difference indicates that FIB milling introduces damage that obviates the need for dislocation nucleation during subsequent deformation. A second effect of FIB milling is that it increased the surface hardness. Together, these effects could be the source of the size effects reported in the literature on micropillar tests.
2007-09-10
Effective numbers of multiquark fluctons in nuclei
Energy Technology Data Exchange (ETDEWEB)
A technique for calculation of the total weight of quark clusters-fluctons: in nuclei is developed. Blokhintsev's formula is justified microscopically and refined by introduction of spin-charge and quark factors. It is shown that the large values of the correlation radius (R/sub C/approx. =0.75 fm or 1.0 fm) derived from experimental data in various papers using this formula correspond to )similarreverse arrowto)2.5 times smaller internucleon distances in the flucton (0.3--0.4 fm), i.e., the hardness of fluctons is caused by unsuppressed manifestation of hidden color at such distances (the corresponding probabilities are presented)
1987-08-01
Effective numbers of multiquark fluctons in nuclei
International Nuclear Information System (INIS)
A technique for calculation of the total weight of quark clusters-fluctons: in nuclei is developed. Blokhintsev's formula is justified microscopically and refined by introduction of spin-charge and quark factors. It is shown that the large values of the correlation radius (R/sub C/#approx =#0.75 fm or 1.0 fm) derived from experimental data in various papers using this formula correspond to #left brace#similarreverse arrowto#right brace#2.5 times smaller internucleon distances in the flucton (0.3--0.4 fm), i.e., the hardness of fluctons is caused by unsuppressed manifestation of hidden color at such distances (the corresponding probabilities are presented).
International Nuclear Information System (INIS)
Polymer composites are used in numerous applications. In spite of this fact, new developments are still under way to explore in other field of application of these materials and to tailor their properties for more extreme condition. A particular emphasis is focused on fillers content is summarized. Some steps towards the functionally graded materials are illustrated. The FT-IR spectroscopic studies revealed the information about curing of epoxy with fillers. It was observed that mechanical properties like tensile strength, hardness etc get enhanced up with filler contents. The effect of the different formulations were investigated and discussed for optimum process condition. (author)
1398-01-01
International Nuclear Information System (INIS)
The ion nitriding treatment is a process widely used in steel alloys to improve the material's properties; such as surface hardness, resistance to wear, fatigue life and resistance to corrosion. But geometric changes in the components can produce during the nitriding process different effects on the behavior of the plasma, such as local variations in the electric field, an empty cathode effect, etc. These in turn can affect among other factors the local temperature and therefore the kinetics of the process, generating variations in the compound layer thicknesses and zone of diffusion, and micro-hardness profile. These heterogeneities limit the effectiveness of the plasma nitriding process, where control and duplication of the surface modification are most important. This work aims to study the effect of the geometry of the pieces treated with ionic nitriding, especially the effect of the orifices. An understanding of the operating mechanisms is ...
2006-12-01
International Nuclear Information System (INIS)
"2H, "4He, "1"6O, "4"0Ca, "8"0Zr, "1"4"0Yb, "2"2"4112, "3"3"6168 nuclei are invesigated in terms of flucton model. Effective numbers of nuclear fluctons and deuterons are calculated. Values of complete effective numbers of low-radius deuterons and fluctons with S=1 spin and T=0 isospin are presented. Investigation results of inclusive reactions of quasi-elastic knock-out of deuterons by fast protons are discussed. 9 refs.; 1 fig.; 1 tab.
1988-06-14
International Nuclear Information System (INIS)
Nano-indentation has been used to assess the hardness of equiaxed grains of #alpha#-Ti as a function of orientation. Surface normals of these grains in metallographic sections were assessed using orientation imaging microscopy. Thin membranes of material from below a series of nano-indentations were excised by use of a dual-beam focused ion beam instrument. In this way, the dislocation substructures beneath individual indentations were characterized using transmission electron microscopy, permitting an identification of both statistically stored and geometrically necessary dislocations.
2005-07-25
Aqueous radioactive waste bituminization
International Nuclear Information System (INIS)
The bituminzation of decontamination and ion exchange resin stripping wastes with four grades of asphalt was investigated to determine the effects of asphalt type on the properties of the final products. All waste forms deformed readily under light loads indicating they would flow if not restrained. It was observed in all cases that product leaching rates increased as the hardness of the asphalt used to treat the waste increased. If bituminization is adopted for any Ontario Hydro aqueous radioactive wastes they should be treated with soft asphalt to obtain optimum leaching resistance and mechanical stability during interim storage should be provided by a corrosion resistant container.
5049-01-01
A study on an electronically controlled liquefied petroleum gas diesel dual-fuel automobile
Energy Technology Data Exchange (ETDEWEB)
In this paper, the control scheme of a liquefied petroleum gas (LPG)-diesel dual-fuel engine with electronic control is illustrated, the external characteristics and load characteristics of the LPG-diesel dual-fuel engine and the diesel engine are compared and analysed, and the results of automobile road tests are also given. The experimental results show that, compared with diesel, the output performance of dual fuel is not reduced, while smoke emission of dual fuel is significantly reduced, NO{sub x} emission of dual fuel is hardly changed, but HC emission and CO emission of dual fuel are increased and fuel consumption of dual fuel is reduced. (Author)
2005-02-15
Energy Technology Data Exchange (ETDEWEB)
Austenitic 316LN alloy was ion-irradiated using the unique Triple Ion Beam Facility (TIF) at ORNL to investigate radiation damage effects relevant to spallation neutron sources. The TIF was used to simulate significant features of GeV proton irradiation effects in spallation neutron source target materials by producing displacement damage while simultaneously injecting helium and hydrogen at appropriately high gas/dpa ratios. Irradiations were carried out at 80, 200, and 350 C using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} to accumulate 50 dpa by Fe, 10,000 appm of He, and 50,000 appm of H. Irradiations were also carried out at 200 C in single and dual ion beam modes. The specific ion energies were chosen to maximize the damage and the gas accumulation at a depth of {approximately} 1 {micro}m. Variations in microstructure and hardness of irradiated specimens were studied using transmission electron microscopy (TEM) and a nanoindentation ...
1997-09-01
Saddle field fast atom beam source: A new low pressure plasma nitriding method for a alloy Ti-6Al-4V
Energy Technology Data Exchange (ETDEWEB)
Ti and its alloys (Ti-6Al-4V) have been used in different engineering applications due to their several outstanding properties. Nevertheless, their use in practical applications is limited in many cases due to their poor tribological property. Researches are ongoing on surface modification of Ti based materials by different plasma and ion based techniques to overcome this problem. However, the conventional plasma nitriding techniques have several problems such as formation of an arc, increased possibility of surface contamination due to a comparatively higher operating pressure, production of a very thin nitrided layer after a long processing time, etc. In this present work, the possibility of a new low-pressure plasma nitriding process using a Plasma Enhanced Chemical Vapor Deposition (PECVD) based saddle field fast atom beam source on a Ti-6Al-4V alloy sample is investigated. Plasma nitriding was carried out at 900 deg. C and at a pressure 0.1 Pa for 8 h by using a beam current 0.5 ...
2006-09-25
Saddle field fast atom beam source: A new low pressure plasma nitriding method for a alloy Ti-6Al-4V
International Nuclear Information System (INIS)
Ti and its alloys (Ti-6Al-4V) have been used in different engineering applications due to their several outstanding properties. Nevertheless, their use in practical applications is limited in many cases due to their poor tribological property. Researches are ongoing on surface modification of Ti based materials by different plasma and ion based techniques to overcome this problem. However, the conventional plasma nitriding techniques have several problems such as formation of an arc, increased possibility of surface contamination due to a comparatively higher operating pressure, production of a very thin nitrided layer after a long processing time, etc. In this present work, the possibility of a new low-pressure plasma nitriding process using a Plasma Enhanced Chemical Vapor Deposition (PECVD) based saddle field fast atom beam source on a Ti-6Al-4V alloy sample is investigated. Plasma nitriding was carried out at 900 deg. C and at a pressure 0.1 Pa for 8 h by using a beam current 0.5 ...
2006-09-25
Reactive magnetron sputtering of hard Si-B-C-N films with a high-temperature oxidation resistance
International Nuclear Information System (INIS)
Based on the results obtained for C-N and Si-C-N films, a systematic investigation of reactive magnetron sputtering of hard quaternary Si-B-C-N materials has been carried out. The Si-B-C-N films were deposited on p-type Si(100) substrates by dc magnetron co-sputtering using a single C-Si-B target (at a fixed 20% boron fraction in the target erosion area) in nitrogen-argon gas mixtures. Elemental compositions of the films, their surface bonding structure and mechanical properties, together with their oxidation resistance in air, were controlled by the Si fraction (5-75%) in the magnetron target erosion area, the Ar fraction (0-75%) in the gas mixture, the rf induced negative substrate bias voltage (from a floating potential to -500 V) and the substrate temperature (180-350 deg. C). The total pressure and the discharge current on the magnetron target were held constant at 0.5 Pa and 1 A, respectively. The energy and flux of ions bombarding the growing films were ...
2005-11-01
International Nuclear Information System (INIS)
The hard-sphere radial distribution functions, g_H_S(r/d,#eta#), for the face-centered cubic and hexagonal close-packed phases have been computed by the Monte Carlo method at nine values of the packing fraction, #eta#[=(#pi#/6)#rho#d"3], ranging from 4% below the melting density to 99% of the close-packed density. The Monte Carlo data are used to improve available analytic expressions for g_H_S(r/d,#eta#). By utilizing the new g_H_S(r/d,#eta#) in the Henderson and Grundke method [J. Chem. Phys. 63, 601 (1975)], we next derive an expression for y_H_S(r/d,#eta#) [=g_H_S(r/d)exp#left brace##beta#V_H_S(r)#right brace#] inside the hard-sphere diameter, d. These expressions are employed in a solid-state perturbation theory [J. Chem. Phys. 84, 4547 (1986)] to compute solid-state and melting properties of the Lennard-Jones and inverse-power potentials. Results are in close agreement with Monte Carlo and lattice-dynamics calculations performed in this ...
1991-11-01
Electrolytic plasma processing of steel surfaces
International Nuclear Information System (INIS)
The thermo-chemical treatments of steels with plasma is normally carried out in low-pressure ionized gaseous atmospheres. Among the treatments used most often are: nitruration, carburization and boronized. A plasma can also generate at atmospheric pressure. One way to produce it is with an electrochemical cell that works at a relatively high inter-electrode voltage and under conditions of heavy gas generation. This type of plasma is known as electrolytic plasma. This work studies the feasibility of using electrolytic plasma for the surface processing of steels. Two processes were selected: boronized and nitruration., for the hardening of two types of steel: one with low carbon (1020) and one with low alloy (4140). In the case of the nitruration, the 1020 steel was first aluminized. The electrolytes were aqueous solutions of borax for the boronizing and urea for the nitruration. The electrolytic plasmas were classified qualitatively, in relation with their luminosity by low, medium and ...
2006-12-01
International Nuclear Information System (INIS)
Effect of helium and hydrogen production on radiation-hardening of F82H irradiated by dual or triple beam condition were investigated. The specimens used were four types of ferritic martensitic steels of F82H-std (Fe-8Cr-2W-0.2V-0.04Ta-0.1C) steels tempered at 750degC for 60 minutes, 20% cold worked F82H steel, F82H tempered for 10 minutes and non-tempered F82H steels. The irradiation was performed at 450degC to 50 dpa under simultaneous dual beams of 10.5 MeV Fe"3"+ and 1.05 MeV He"+ or triple beams of those and 380 keV H"+ ions. The ratios of He (appm)/dpa and H(appm)/dpa were 15 nad 15 (or 150) for dual and triple ion beams. The hardness of the irradiated specimens measured at room temperature using a micro indentation after the irradiations. The hardness in these F82H steels irradiated at 450degC to 18 dpa under triple beam irradiation was harder than that under dual beam irradiation. Irradiation softening and hardening under dual beams was ...
2003-03-01
DIVALENT ION EXCHANGE WITH ALKALI
Energy Technology Data Exchange (ETDEWEB)
Exchange of hardness ions is important in enhanced oil recovery with chemical additives. In both micellar-polymer and caustic flooding processes, multivalent ions released from rock surfaces can interact with anionic surfactants, rendering them preferentially oil soluble and/or insoluble in water. Because hardness cations are sparingly soluble and precipitate in alkaline solutions, such solutions may be more efficient as surfactant flood preflushes than are softened brines. Multivalent ion precipitation may also occur in alkaline waterflooding. To permit design of such processes, this paper presents a chromatographic theory for simultaneous ion exchange with precipitation of divalent ions. Theoretical effluent histories and concentration profiles are presented for the cases of finite pulses and continuous injection of hydroxide ions into linear cores. Complete capture of the insoluble salt particles is assumed. Results are given for the case of ...
1980-05-01
International Nuclear Information System (INIS)
Depth sensing indentation tests were carried out to obtain load-penetration depth curves of SiAlON-ZrO_2 ceramics under different peak loads ranging from 200 to 1800 mN. The values of indentation hardness (H_O_P, H_C_C) and reduced elastic modulus (E_O_P, E_C_C) were calculated by using Oliver-Pharr (OP) and Cheng-Cheng (CC) methods. The experimental results revealed that the indentation hardness and reduced elastic modulus exhibit peak-load dependence, i.e. indentation size effect. Both indentation hardness and reduced elastic modulus values were obtained by considering indenter tip roundness and machine compliance. These values obtained from the OP method are higher than from the CC method. On the other hand, h_f/h_m ratios were used to clarify the indentation deformation behaviour of the SiAlON-ZrO_2 ceramic. The experimental h_f/h_m values were lower than the reported critical value (0.7) for all applied test loads, ...
2008-02-07
Transplacental movement of inorganic lead in early and late gestation in the mouse
Energy Technology Data Exchange (ETDEWEB)
/sup 203/Pb(NO/sub 3/)/sub 2/ was administered i.v. to pregnant C57BL mice at different stages, from day 8 to day 18 of gestation. The whole animals or excised uteri were subjected to autoradiography or were autopsied for scintillation counting of excised organs. Lead appeared in embryonic and fetal tissues at all stages of gestation. Early (approx. day 8-11) lead was restricted mainly to the embryonic blood, suggesting that free lead was essentially not transferred to the embryo but may have been incorporated in the embryonic hemoglobin when the erythrocytes were formed in the yolk sac placenta (an extraembryonic membrane). From day 12 and later, an uptake was seen in the liver and the cartilaginous skeleton, and from day 14, a strong accumulation was found in calcified bone. This means that the overall fetal concentration increases successively with gestational age of the conceptus. The uptake in fetal liver may be related to the erythropoiesis taking place in ...
1983-10-01
Transplacental movement of inorganic lead in early and late gestation in the mouse
International Nuclear Information System (INIS)
"2"0"3Pb(NO_3)_2 was administered i.v. to pregnant C57BL mice at different stages, from day 8 to day 18 of gestation. The whole animals or excised uteri were subjected to autoradiography or were autopsied for scintillation counting of excised organs. Lead appeared in embryonic and fetal tissues at all stages of gestation. Early (approx. day 8-11) lead was restricted mainly to the embryonic blood, suggesting that free lead was essentially not transferred to the embryo but may have been incorporated in the embryonic hemoglobin when the erythrocytes were formed in the yolk sac placenta (an extraembryonic membrane). From day 12 and later, an uptake was seen in the liver and the cartilaginous skeleton, and from day 14, a strong accumulation was found in calcified bone. This means that the overall fetal concentration increases successively with gestational age of the conceptus. The uptake in fetal liver may be related to the erythropoiesis taking place in the liver in ...
The ''nuclear car wash'': a scanner to detect illicit special nuclear material in cargo containers
International Nuclear Information System (INIS)
There is an urgent need to improve the reliability of screening cargo containers for illicit nuclear material that may be hidden there for terrorist purposes. A screening system is described for detection of fissionable material hidden in maritime cargo containers. The system makes use of a low intensity neutron beam for producing fission; and the detection of the abundant high-energy #gamma# rays emitted in the #beta#-decay of short-lived fission products and #beta#-delayed neutrons. The abundance of the delayed #gamma# rays is almost an order of magnitude larger than that of the delayed neutrons normally used to detect fission and they are emitted on about the same time scale as the delayed neutrons, i.e., #approx#1 min. The energy and temporal distributions of the delayed #gamma# rays provide a unique signature of fission. Because of their high energy, these delayed #gamma# rays penetrate loW--Z cargoes much more readily than the delayed neutrons. Coupled with their higher ...
2004-01-28
Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997
Energy Technology Data Exchange (ETDEWEB)
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...
1998-03-01
Radon generation and transport in and around a gold mine tailings dam in South Africa
Energy Technology Data Exchange (ETDEWEB)
Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the M.E.D.U.S.A. system. Radon soil gas measurements were performed at ...
2006-07-01
Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes
International Nuclear Information System (INIS)
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the administered activity. ...
1982-06-25
Pulmonary retention of lead: an experimental study in man
Energy Technology Data Exchange (ETDEWEB)
This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size (MMAD 0.25 ..mu..m +- 0.1) by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of 12 2-in. scintillation detectors and two 2-in. leg counters, all coupled to single channel analyzers. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 h. When the retention data were corrected for blood-borne /sup 203/Pb, the biological halftimes ...
1980-04-01
Prompt fission neutron energy spectra induced by fast neutrons
International Nuclear Information System (INIS)
Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron energies were determined by time-of-flight techniques with pulse-shape ...
Nuclear radiation detectors on II-VI compounds
International Nuclear Information System (INIS)
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 A/cm"2 (R/min); the experimental value of dose sensitivity reaches ...
1993-10-13
HALO - the helium and lead observatory for supernova neutrinos
Energy Technology Data Exchange (ETDEWEB)
The Helium and Lead Observatory (HALO) is a supernova neutrino detector under development for construction at SNOLAB. It is intended to fulfill a niche as a long term, low cost, high livetime, and low maintenance, dedicated supernova detector. It will be constructed from 80 tonnes of lead, from the decommissioning of the Deep River Cosmic Ray Station, and instrumented with approximately 384 meters of {sup 3}He neutron detectors from the final phase of the SNO experiment. Charged- and Neutral-Current neutrino interactions in lead expel neutrons from the lead nuclei making a burst of detected neutrons the signature for the detection of a supernova. Existing neutrino detectors are mostly of the water Cerenkov and liquid scintillator types, which are primarily sensitive to electron anti-neutrinos via charged-current interactions on the hydrogen nuclei in these materials. By contrast, the large neutron excess of a heavy nucleus like Pb acts to Pauli-block p)n ...
2008-11-01
Evaluation of femoral neck fracture healing in man by serial sup(99m)Tc-diphosphonate scintimetry
Energy Technology Data Exchange (ETDEWEB)
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hip areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the normal healing group 10 ...
1981-02-01
Evaluation of femoral neck fracture healing in man by serial sup(99m)Tc-diphosphonate scintimetry
International Nuclear Information System (INIS)
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hips areas were made with a scintillation camera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the normal healing group 10 ...
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in RB in the accessible areas and out side the RE containment, the travel time for the ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
The processes of lung growth, injury, and repair are characterized by alterations in fibroblast synthesis and interstitial distribution of extracellular matrix components. Transforming growth factor beta (TGF-beta), which is postulated to play a role in modulating lung repair, alters the distribution of several matrix components such as collagen and fibronectin. We studied the effect of TGF-beta on the synthesis and distribution of the various glycosaminoglycans (GAGs) and whether these effects may explain its role in lung repair. Human diploid lung fibroblasts (IMR-90) were exposed to various concentrations of TGF-beta (0-5 nM) for variable periods of time (0-18 h). Newly synthesized GAGs were labeled with either (3H)glucosamine or (35S)sulfate. Individual GAGs were separated by size exclusion chromatography after serial enzymatic and chemical digestions and quantitated using scintillation counting. There was a dose-dependent increase in total GAG synthesis with ...
1990-09-01
Development of low-level liquid-waste treatment systems: April-September 1982
Energy Technology Data Exchange (ETDEWEB)
A preliminary investigation was conducted on ion specific membranes. This investigation concentrated on testing candidate organic compounds for transporting cesium ions through a membrane composed of the organic compound supported on a substrate. Solid PVC membranes were initially tried, but were found to be too slow. Thereafter, only liquid membranes were tested. These were faster and cesium concentration factors up to 2.96 were achieved in a single membrane cell. A cell with two membranes achieved a cesium concentration factor of 4.19. Cesium precipitation with sodium tetraphenyl borate in high sodium concentrations was explored. No interference from sodium was found until the sodium nitrite concentration reached 4.5 moles. Concurrently, cesium concentrations as high as 5.4 g/L were precipitated. Potassium tetraphenyl borate is being investigated for use in exchange columns for the removal of cesium from solutions. Initial investigations show that cesium removal is affected by (K/sup ...
1982-12-22
Development of low-level liquid-waste treatment systems: April-September 1982
International Nuclear Information System (INIS)
A preliminary investigation was conducted on ion specific membranes. This investigation concentrated on testing candidate organic compounds for transporting cesium ions through a membrane composed of the organic compound supported on a substrate. Solid PVC membranes were initially tried, but were found to be too slow. Thereafter, only liquid membranes were tested. These were faster and cesium concentration factors up to 2.96 were achieved in a single membrane cell. A cell with two membranes achieved a cesium concentration factor of 4.19. Cesium precipitation with sodium tetraphenyl borate in high sodium concentrations was explored. No interference from sodium was found until the sodium nitrite concentration reached 4.5 moles. Concurrently, cesium concentrations as high as 5.4 g/L were precipitated. Potassium tetraphenyl borate is being investigated for use in exchange columns for the removal of cesium from solutions. Initial investigations show that cesium removal is affected by [K"+] ...
Development of a neutron/. gamma. ray radiation monitor
Energy Technology Data Exchange (ETDEWEB)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the ...
1983-01-01
Development of a neutron/#gamma# ray radiation monitor
International Nuclear Information System (INIS)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...
1983-01-01
Development of a Neutron/gamma Ray Radiation Monitor.
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting equations using a linearized approximation to the electron ...
1983-01-01
International Nuclear Information System (INIS)
In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas can then be used to determine the proton beam range or the distal dose edge in the patient. In this study, the PGS system was ...
2007-09-21
Calibration of cylindrical detectors using a simplified theoretical approach
Energy Technology Data Exchange (ETDEWEB)
The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing corrections, respectively. Here, we introduce a new theoretical approach based on the Direct ...
2006-09-15
Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests
Energy Technology Data Exchange (ETDEWEB)
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass ...
2010-09-07
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side the RB containment, the travel time for the feed water becomes very long resulting ...
2005-11-23
International Nuclear Information System (INIS)
A gel-type "9"9Mo-"9"9"mTc generator using Titanium-Molybdate target (TiMo-target) as column packing was developed in Radioisotope Department, the Dalat Nuclear Research Institute [1]. The concentration of trace elements in TiMo-target and radionuclidic purity in "9"9"mTc solution eluted from this type of generator were studied for quality control purpose. The monostandard method in neutron activation analysis has been applied to determine the concentration of trace impurities in titanium-molybdate target. For neutron activation analysis, TiMo samples were irradiated in the different channels of nuclear reactor IVV-9 at a neutron flux of maximum 2.1 x 10"1"3 n.cm"-"2s"-"1. The following chemical element impurities were determined: Na, W, Co, Fe, Zn, Ag, Sb and Cr. The gamma ray emitted nuclides found in "9"9"mTc solution eluted from our "9"9"mTc generator were the following: "6"5Zn, "6"0Co, "1"1"0"mAg, "5"9Fe, "5"1Cr, "2"4Na, "8"2Br and "9"9Mo. "9"9Mo was found less than 2.10"-"6mCi ...
2004-06-01
A high-sensitivity small animal SPECT system
International Nuclear Information System (INIS)
Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into new tracer compounds, and reducing the cost ...
2009-03-07
/sup 242/Am/sup m/ fission cross section
Energy Technology Data Exchange (ETDEWEB)
The neutron-induced fission cross section of /sup 242/Am/sup m/ has been measured over the energy region from 10/sup -3/ eV to approx.20 MeV in a series of experiments utilizing a linac-produced ''white'' neutron source and a monoenergetic source of 14.1 MeV neutrons. The cross section was measured relative to that of /sup 235/U in the thermal (0.001 to approx.3 eV) and high energy (1 keV to approx.20 MeV) regions and normalized to the ENDF/B-V /sup 235/U(n,f) evaluated cross section. In the resonance energy region (0.5 eV to 10 keV) the neutron flux was measured using thin lithium glass scintillators and the relative cross section thus obtained was normalized to the thermal energy measurement. This procedure allowed a consistency check between the thermal and high energy data. The cross section data have a statistical accuracy of approx.0.5% at thermal energies and in the 1-MeV energy region, and a systematic uncertainty of ...
1984-06-01
ADVANCED UNDERGROUND GAS STORAGE CONCEPTS REFRIGERATED-MINED CAVERN STORAGE
Energy Technology Data Exchange (ETDEWEB)
Limited demand and high cost has prevented the construction of hard rock caverns in this country for a number of years. The storage of natural gas in mined caverns may prove technically feasible if the geology of the targeted market area is suitable; and economically feasible if the cost and convenience of service is competitive with alternative available storage methods for peak supply requirements. It is believed that mined cavern storage can provide the advantages of high delivery rates and multiple fill-withdrawal cycles in areas where salt cavern storage is not possible. In this research project, PB-KBB merged advanced mining technologies and gas refrigeration techniques to develop conceptual designs and cost estimates to demonstrate the commercialization potential of the storage of refrigerated natural gas in hard rock caverns. Five regions of the U.S.A. were studied for underground storage development and PB-KBB reviewed the literature ...
1998-09-01
[Clinico-hormonal correlations in patients with chronic alcoholic intoxication].
Radioimmunochemical assay was used to study the hypophyseal and peripheral hormones activity in 60 patients with chronic alcoholism, stage II. A correlation has been established between the patient's age and prolactin and FSH concentrations, as well as between the duration of the recent hard drinking and the concentrations of prolactin, testosterone, FSH and interstitial cell stimulating hormone. It has been shown that the manifestation of the alcoholic abstinent syndrome depended on the prolactin concentration. The test sensitivity estimated by the prolactin level rise and the testosterone level reduction reached 92.3%. The specificity of the changes detected comprised 25%. A conclusion has been made that the disorders noted in the patients with chronic alcoholic intoxication can be used as an objective test in the alcoholism diagnosis. PMID:3936321
1985-01-01
X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating
International Nuclear Information System (INIS)
We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.
2010-06-23
Wear and machining of engineering ceramics by abrasive waterjets
Energy Technology Data Exchange (ETDEWEB)
The purpose of this investigation was to simulate a machining front from an abrasive waterjet and its movements in a ceramic material. Wear factors affecting the abrasive waterjet nozzle were also to be established. Therefore, a low inclination angle (9[degree]) was used between the nozzle and test sample, simulating a moving machine front. A standard nozzle with an inner diameter of 0.76 mm was used in the test, and it was placed close to the samples. The outer diameter of the abrasive nozzle was 9.5 mm. The high wear rate from abrasive waterjets makes it possible to machine hard ceramics-including dense alumina, titanium boride, silicon nitride, and composites-at high machining speeds.
1993-08-01
Tunneling magnetoresistance from a symmetry filtering effect
International Nuclear Information System (INIS)
This paper provides a brief overview of the young, but rapidly growing field of spintronics. Its primary objective is to explain how as electrons tunnel through simple insulators such as MgO, wavefunctions of certain symmetries are preferentially transmitted. This symmetry filtering property can be converted into a spin-filtering property if the insulator is joined epitaxially to a ferromagnetic electrode with the same two-dimensional symmetry parallel to the interface. A second requirement of the ferromagnetic electrodes is that a wavefunction with the preferred symmetry exists in one of the two spin channels but not in the other. These requirements are satisfied for electrons traveling perpendicular to the interface for Fe-MgO-Fe tunnel barriers. This leads to a large change in the resistance when the magnetic moment of one of the electrodes is rotated relative to those of the other electrode. This large tunneling magnetoresistance effect is being used as the read sensor in ...
2008-04-01
Transport properties and Langevin dynamics of heavy quarks and quarkonia in the Quark Gluon Plasma
Quark Gluon Plasma transport coefficients for heavy quarks and quark-antiquark pairs are computed through an extension of the results obtained for a hot QED plasma by describing the heavy-quark propagation in the eikonal approximation and by weighting the gauge field configurations with the Hard Thermal Loop effective action. It is shown that such a model allows to correctly reproduce, at leading logarithmic accuracy, the results obtained by other independent approaches. The results are then inserted into a relativistic Langevin equation allowing to follow the evolution of the heavy-quark momentum spectra. Our numerical findings are also compared with the ones obtained in a strongly-coupled scenario, namely with the transport coefficients predicted (though with some limitations and ambiguities) by the AdS/CFT correspondence.
2009-01-01
Transforming Critical Spreadsheets into Web Applications at Zurich Financial
In the insurance industry, spreadsheets have emerged as an invaluable tool to for product pricing, because it is relatively straightforward to create and maintain complex pricing models using Excel. In fact, Excel is often preferred to "hard-code" whenever there are frequent changes to the calculations and business logic which under-pin the pricing of an insurance product. However, problems arise as soon as spreadsheets are deployed to end-users: version control, security of intellectual property, and ensuring correct usage are obvious issues; frequently, integration with other systems is also a requirement. Zurich Financial Services Group is a leading financial services provider; several possible solutions to these problems have been evaluated, and EASA has been selected as the preferred technology. Other spreadsheet collaboration approaches which were considered include Excel Services, and/or custom-built software; however, EASA has provided clear benefits over ...
2010-01-01
Toxicity and gross pathology of ivermectin bath treatment in sea bream Sparus aurata, L.
British Library Electronic Table of Contents (United Kingdom)
The isopod parasite Ceratothoa oestroides becomes hard to eradicate in intensive fish rearing systems and in addition to causing weight loss in adult fish it causes mortalities in larval and juveniles stages of sea bass and sea bream. Faced with the fast emergence of this infection in Adriatic finfish facilities, an effective compound had to be tested for bath treatment. Ivermectin was chosen for this purpose on the basis of extensive practice in northern European countries which used ivermectin administered in food with good results in treatment of Lepeophtheirus sp. and Caligus sp. infections. For determination of toxicity of ivermectin, a short-term toxicity bioassay on 40-day-old sea bream, Sparus aurata, L., was conducted, following FAO and UNEP procedures for methodology in aquatic t...
2006-01-01
Thermal and mechanical properties of poly(vinyl alcohol) plasticized with glycerol
British Library Electronic Table of Contents (United Kingdom)
Abstract Thermomechanical behavior of membranes based on blends of poly(vinyl alcohol) (PVA) with different weight percentage (wt %) of glycerol has been studied. Solid-state PVA/Glycerol polymer membranes were prepared by a solution casting method. The films were studied for thermal characteristics by differential scanning calorimetry (DSC) and thermogravimetric analysis and for the mechanical properties including hardness and modulus by nanoindentation method. The dispersion of glycerol within the polymer matrix was examined using scanning electron microscopy. Fourier transform infrared spectroscopy was used to confirm the formation of hydrogen bonding between the plasticizer and PVA in their blends and also to provide information on compatibility and physical interactions between the gl...
2011-01-01
The rapid nitriding of Al alloys with the controlling of plasma power density and pretreatments
Energy Technology Data Exchange (ETDEWEB)
The properties of AlN make this material very attractive for optical, electronic, and tribological application. Also, if the AlN could be formed on the Al surface to enhance its surface properties, Al could be applied for the lightening of machine parts. However, a dense oxide film exists on the surface of Al, which prevents the formation of the Al nitride even during plasma nitriding and plasma coating process. In this study, plasma nitriding has been tried to form an AlN layer on Al after the surface activation processes. During the plasma nitriding, the density of the nitrogen ions was amplified by means of controlling the power of the Al substrates. The film thickness, microstructural features and the mechanical properties such as hardness and wear properties of the AlN layer were examined as a function of the process parameters of pretreatment and plasma nitriding
2010-05-15
The gamma radiation in improving the physical properties of wood-polymer composites
International Nuclear Information System (INIS)
In the Peruvian natural forest there are several kind of woods, some of those are not of commercial interest, because have not resistance at termites and wet, are too soft, or can not be well finished, in the others. The present work is devoted to improvement of the physical properties of wood, such as hardness, traction, wet resistance, etc., by means of the generation of a composite wood-polymers cured by using gamma irradiation. The main objective is to establish the main parameters for the polymerization process (economic technical aspect) that decrease the amount of water absorption, in consequence the volumetric variation of Catahua, Mohena and Capirona woods. Gamma irradiation also provides good protection against the biological agents. In consequence, these woods increase its intrinsic and economic values. (author)
2006-07-01
British Library Electronic Table of Contents (United Kingdom)
This work is focused on effect of various cooling strategies on surface roughness and tool wear during computer aided milling of soft workpiece materials. These milling operations were selected as dry milling, cool air cooling milling and fluid cooling milling. A cool air cooling system was designed and produced to cool end milling tools. Cool air was produced by a vortex tube. Annealed AISI 1050 was used as the workpiece material and cutting tool material was selected as HSS-Co8 DIN 844/BN. Optimal cutting parameters were selected according to workpiece hardness from reference catalog and kept for all tests. Tool wear and surface quality were measured for three different cooling types changing from ten minute machining time to thirty minute machining time. As a result, the surface roughne...
2009-01-01
Technology assessment: Chlorine chemistry
International Nuclear Information System (INIS)
Chlorine is not just one of many chemical feedstocks which is used in a few definitely harmful products like PVC or CFC but is irrelevant in all other respects. Just the opposite is true: There is hardly any product line of the chemical industry that can do without chlorine, from herbicides and pesticides to dyes, plastics, pharmaceuticals, photographic atricles, and cosmetics. Chlorine is not only a key element of chemical production but also an ubiquitous element of everyday life in civilisation. There are even many who would agree that the volume of chlorine production is an indicator of the competitive strength and national wealth of a modern society. By now, however, it has become evident that the unreflected use of chlorine is no longer ecologically acceptable. The consequences of a chlorine phase-out as compared to the continued chlorine production at the present level were investigated scientifically by a PROGNOS team. They are presented in this book. ...
British Library Electronic Table of Contents (United Kingdom)
With conventional heating process, ultraviolet (UV) illumination, and microwave irradiation, we have successfully synthesized UV curable encapsulating adhesives with excellent gas barrier capabilities, good adhesive strength, moderate hardness, and high refractive indices. The experimental results manifest that the physical properties of lab-made encapsulating adhesives are highly dependent on their chemical structures and synthetic procedure. We also discover that the encapsulating adhesive prepared by microwave irradiation (i.e. encapsulating adhesive VI-MW) exhibits better adhesive strength and higher gas resistance than those prepared by conventional heating process and UV illumination. Furthermore, encapsulating adhesive VI-MW has also been applied for the package of organic light emi...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Stainless steels can be nitrided at temperatures {<=}400 C to increase their hardness and wear resistance without a decreasing of their excellent corrosion resistance. Structure and properties of the surface layers produced by plasma nitriding and plasma immersion ion implantation in this temperature range were tested. There are negligible differences in the structure of the produced surface layers in spite of different interaction principles of the used technologies. However there are clear differences between the case of different steels. The case of ferritic chromium steels mainly consists of {epsilon}-nitride. Whereas the cases of austenitic and ferritic austenitic steels are characterized by expanded austenite. The corrosion resistance of the steels is reduced by nitriding only, if evident CrN-formation occurs. (orig.) 11 refs.
1999-08-01
Sliding wear of metal-ceramic systems with oscillating load
Energy Technology Data Exchange (ETDEWEB)
The tribological behavior of SiSiC/100Cr6-, Si/sub 3/N/sub 4//100Cr6- und Al/sub 2/O/sub 3//100Cr6-pairs has been investigated with oscillating load on a spherical disc/disc tribometer. The prevailing wear mechanism of the Si ceramics is tribooxidation, which leads to the formation of a SiO/sub 2/ protective layer with a reduction in friction and wear. With frequencies >1 kHz, this effect increases, resulting in low friction coefficients and wear rates. The prevailing mechanism of the oxid ceramic is surface fatigue. The hard wear particles produce severe abrasive wear. This effect is intensified with higher frequencies.
1989-05-01
International Nuclear Information System (INIS)
Selective formation of ZnO nanodots was accomplished by metalorganic chemical vapor deposition on nanopatterned SiO_2/Si substrates. Self-organized ZnO nanodots were selectively formed in nanopatterned lines of Si created by etching of SiO_2 with focused ion beam (FIB), whereas any nanodots were hardly observed on the SiO_2 surface in the vicinity of the FIB-sputtered Si areas. The mechanism of the selective formation of ZnO nanodots on FIB-nanopatterned lines is mainly attributed to the effective migration of Zn adatoms diffusing on the SiO_2 surface into the Si lines followed by the nucleation at surface atomic steps and kinks created by Ga"+ ion sputtering. Cathodoluminescence measurements confirmed that the emission originated from the selectively grown ZnO nanodots.
2003-10-27
British Library Electronic Table of Contents (United Kingdom)
Purpose - The purpose of this paper is to verify the proposition by the University of Illinois, Urbana-Champaign (UIUC), that their return on investment (ROI) formula developed for academic libraries and based on hard facts is broad enough to be used throughout the world for ROI studies in academic institutions/libraries. It further aims to verify that UIUC's methodology is adaptable enough to work in other academic environments as well. Design/methodology/approach - The methodology developed by UIUC (an ROI formula developed for academic libraries based on grant proposal applications and citations) has been "copied" and thereby adapted to enable it to be used in an academic environment in Europe/Germany. Findings - The methodology developed by UIUC was adaptable enough to be used in a Ger...
2010-01-01
Reborn quadrant anode image sensor
International Nuclear Information System (INIS)
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial resolution better then 50?m and count rates up to one million events per second.
2009-06-01
Reborn quadrant anode image sensor
British Library Electronic Table of Contents (United Kingdom)
We describe a position sensitive photon counting microchannel plate based detector with an improved quadrant anode (QA) readout system. The technique relies on a combination of the four planar elements pattern and an additional fifth electrode. The charge cloud induced by single particle detection is split between the electrodes. The measured charge values uniquely define the position of the initial event. QA has been first published in 1976 by Lampton and Malina. This anode configuration was undeservedly forgotten and its potential has been hardly underestimated. The presented approach extends the operating spatial range to the whole sensitive area of the microchannel plate surface and demonstrates good linearity over the field of view. Therefore, the novel image sensor results in spatial...
2009-01-01
International Nuclear Information System (INIS)
Rapid self-aggregation of Ni nanodots on Si substrate covered with a thin SiO_2 buffered layer is investigated. The Ni nanodots can hardly self-aggregate on highly heat-dissipated Si substrate with a thermal conductivity of 148 W/m K. Adding a 200-A-thick SiO_2 buffer with an ultralow thermal conductivity of 1.35 W/m K prevents the formation of NiSi_2 compounds, enhances the heat accumulation, and releases the adhesion at Ni/Si interface, which greatly accelerates the self-assembly of Ni nanodots. Dense Ni nanodots with size and density of 30 nm and 7x10"1"0 cm"-"2, respectively, can be formatted after rapid thermal annealing at 850 deg. C for 22 s.
2006-08-14
Radiation processed composite materials of wood and elastic polyester resins
International Nuclear Information System (INIS)
The radiation polymerization of multifunctional unsaturated polyester-monomer mixtures in wood forms interpenetrating network system. The mechanical resistance (compression, abrasion, hardness, etc.) of these composite materials are generally well over the original wood, however the impact strength is almost the same or even reduced, in comparison to the wood itself. An attempt is made using elastic polyester resins to produced wood-polyester composite materials with improved modulus of elasticity and impact properties. For the impregnation of European beech wood two types of elastic unsaturated polyester resins were used. The exothermic effect of radiation copolymerization of these resins in wood has been measured and the dose rate effects as well as hardening dose was determined. Felxural strength and impact properties were examined. Elastic unsaturated polyester resins improved the impact strength of wood composite materials. (author).
1982-09-19
Radiation Protection Aspects of the Linac Coherent Light Source Front End
Energy Technology Data Exchange (ETDEWEB)
The Front End Enclosure (FEE) of the Linac Coherent Light Source (LCLS) is a shielding housing located between the electron dump area and the first experimental hutch. The upstream part of the FEE hosts the commissioning diagnostics for the FEL beam. In the downstream part of the FEE, two sets of grazing incidence mirror and several collimators are used to direct the beam to one of the experimental stations and reduce the bremsstrahlung background and the hard component of the spontaneous radiation spectrum. This paper addresses the beam loss assumptions and radiation sources entering the FEE used for the design of the FEE shielding using the Monte-Carlo code FLUKA. The beam containment system prevents abnormal levels of radiations inside the FEE and ensures that the beam remains in its intended path is also described.
2010-08-26
Quartz fiber calorimetry and calorimeters
Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward calorimeters.
2004-01-01
QCD parton showers and NLO EW corrections to Drell-Yan
We report on the implementation of an interface between the SANC generator framework for Drell-Yan hard processes, which includes next-to-leading order electroweak (NLO EW) corrections, and the Herwig++ and Pythia8 QCD parton shower Monte Carlos. A special aspect of this implementation is that the initial-state shower evolution in both shower generators has been augmented to handle the case of an incoming photon-in-a-proton, diagrams for which appear at the NLO EW level. The difference between shower algorithms leads to residual differences in the relative corrections of 2-3% in the p_T(mu) distributions at p_T(mu)>~50 GeV (where the NLO EW correction itself is of order 10%).
2010-01-01
QCD corrections to top quark pair production in association with a photon at hadron colliders
We compute QCD corrections to the production of a ttbar pair in association with a hard photon at the Tevatron and the LHC. This process allows a direct measurement of the top quark electromagnetic couplings that, at the moment, are only loosely constrained. We include top quark decays, treating them in the narrow width approximation, and retain spin correlations of final-state particles. Photon radiation off top quark decay products is included in our calculation and yields a significant contribution to the cross-section. We study next-to-leading order QCD corrections to the ppbar -> ttbar+gamma process at the Tevatron for the selection criteria used in a recent measurement by the CDF collaboration. We also discuss the impact of QCD corrections to the pp -> ttbar+gamma process on the measurement of the top quark electric charge at the 14 TeV LHC.
2011-01-01
Printers: the neglected threat
British Library Electronic Table of Contents (United Kingdom)
One of the issues with printers - or the increasingly common multi-function devices (MFDs) - is that no one takes any notice of them. They just sit there, unacknowledged and ignored, in the corner of the office, printing, photocopying, faxing and even emailing away and no one gives them a second thought. Until something goes wrong. No-one gives printers - or multi-function devices (MFDs) - a second thought, as they have just been sitting there in offices doing their thing for years. But the problem is that they have now grown up to become fully-fledged computers and are starting to present an information security risk. These machines now have operating systems, hard drives and IP addresses, and have been exploited as storage devices by hackers. But most problems stem from poor internal pra...
2011-01-01
Partial unmixing as a tool for single surface class detection and time series analysis
British Library Electronic Table of Contents (United Kingdom)
In this paper we present the results of time series analysis for a coal mining region based on partial unmixing. We test the method also known as mixture tuned matched filtering on an eight image Landsat 5 TM and Landsat 7 ETM+ time series covering the period from 1987 to 2003. Common change detection methods often include the comparison of two interactively generated classification results, such as derived from Maximum Likelihood classification. These approaches often yield highly accurate results. However, disadvantages include a strong analyst bias and hardly repeatable results. For a quantitative monitoring of a single surface class' development over time they are often not recommendable. Our goal was to test an unbiased quantitative way to assess the development of coal surfaces, such...
2008-01-01
International Nuclear Information System (INIS)
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
2009-01-01
Nuclear power plant liquid waste solidification system. [Japan
Energy Technology Data Exchange (ETDEWEB)
The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the power plants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity tests on the final disposal of the pellet bitumen package.
1981-01-01
Nuclear power plant liquid waste solidification system
International Nuclear Information System (INIS)
The fundamental points to be considered in a waste treatment system for a country like Japan, where the final disposal method has not been decided and the wastes have to be stored in the power plants, are volume reduction of the wastes, safe storage of the wastes in the plant, and flexibility regarding the final disposal. A system has been developed that consists of a thin film evaporator for the direct solidification of the liquid waste, a pelletizer for producing hard pellets from the powdered wastes, a pellet storage unit, and a solidification unit for the final disposal. A pilot plant with waste treatment capacity of 200 kg/h was built in 1976 and has proved the system feasibility. This paper reports on pilot plant tests of the thin film evaporator and other components, tests on pellet deterioration during long term storage, and integrity tests on the final disposal of the pellet bitumen package.
1981-02-26
Nonlinear response and stability of a spindle system supported by Ball bearings
Energy Technology Data Exchange (ETDEWEB)
In this effort, the nonlinear responses and stability of a spindle system supported by ball bearings are presented. The dynamics of this system is described by a set of second order differential equations with a nonlinear piecewise smooth force. The Floquet theory is applied to investigate the stability of the periodic solution. Due to the loss of contact between the raceways and balls in the ball bearing, the bending of the frequency response curves switch to the left at the weak resonance region, which is similar to the frequency response curves of a system with a soft spring. With the decrease of the bearing clearance, the bending of the frequency response curves switch to the right, which is similar to the frequency response curves of a system with a hard spring. Increase of the frequency ratio, the bending of frequency response curves transforms from left to right. The route to chaos through a period doubling process is also observed in this spindle-bearing ...
2010-09-15
Energy Technology Data Exchange (ETDEWEB)
Samples of austenitic stainless steel AISI 316 were nitrided using the cathodic cage technique with the addition of methane in the nitriding atmosphere. The aim was to study the influence of this technique in reducing the precipitation of chromium nitrite and in improving the wear resistance. The results show that there was a significant improvement in such properties when compared to the results of ionic plasma nitriding. Formation of a double layer, one more internal composed of carbon and another with high nitrogen content, was confirmed by Scanning Electron Microscopy (SEM). The microhardness profile of the layer showed an increase in hardness values and a larger uniformity, while X-ray analysis showed less chromium nitriding precipitation when compared with results obtained for samples treated using ionic plasma nitriding.
2008-07-25
Experimental measurements were made of the production cross sections and energy distributions of gamma rays emitted when the stable targets /sup 88/Sr, /sup 89/Y and /sup 90/Zr are exposed to protons in the energy range 3 to 8 MeV. The data are being analyzed using a recent version of the Uhl statistical model code. One conclusion is that while the gamma-ray strength functions employed reproduce the proton capture cross sections, they do not achieve the same degree of hardness observed in the measured spectra. To do so, their lower energy regions must be modified; such changes, however, do not affect the capture cross sections. 7 references.
1978-09-01
Network-aware service placement and selection algorithms on large-scale overlay networks
British Library Electronic Table of Contents (United Kingdom)
Currently many service providers offer their services on a private and proprietary hard- and software infrastructure. These infrastructures often share many similarities. Hence we believe a generic service management architecture, that allows service providers to offer a large array of different services on a single infrastructure or multiple providers to offer their services cooperatively, would provide many advantages over current silo-based approaches. Additionally, by allowing the distributed service management components to cooperate in a peer-to-peer overlay network, scalability and resilience of the system could be greatly improved. In this paper we propose an optimal algorithm, based on an integer linear programming (ILP) formulation, and several heuristics to support such a generi...
2011-01-01
Modelling the tribology of thin film interfaces
substrate). Within each group of simulations, three lubricant film thicknesses are studied to examine the effect of varying lubricant thickness. Statistical data are collected from each simulation and presented in this work. Via these data, together with the evolution, of atomic and molecular configurations, a very detailed picture of the properties of this thin film interface is presented. In particular, we conclude that perfluoropolyether lubricant forms distinct molecular layers when confined between two substrates, the rate of heat generation under shearing conditions typical of those in a head-disk interface is insufficient for thermal mechanisms to result directly in lubricant degradation, and mechanical stresses attained in the head-disk interface are unlikely to result in any significant degree of lubricant degradation. This thesis examines the tribology of a head-disk interface in an operating hard disk drive via non-equilibrium molecular dynamics computer ...
2000-01-01
Modeling and control of a novel heat exchange reactor, the Open Plate Reactor
British Library Electronic Table of Contents (United Kingdom)
A new chemical reactor, the Open Plate Reactor, is being developed by Alfa Laval AB. It combines good mixing with high heat transfer capacity into one operation. With the new concept, highly exothermic reactions can be produced using more concentrated reactants. A nonlinear model of the reactor is derived and a control system is developed. For temperature control a cooling system is designed and experimentally verified, which uses a mid-ranging control structure to increase the operating range of the hydraulic equipment. A Model Predictive Controller is proposed to maximize the conversion under hard input and state constraints. An extended Kalman filter is designed to estimate unmeasured concentrations and parameters. Simulations show that the designed control system gives high conversion ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
AISI 316L stainless steel was welded by the electron beam (EB) and laser techniques. Microstructural characteristics, hardness profile, creep rupture properties and creep damage of the welds were investigated. Fully austenitic microstructure was obtained in the two welds. The solidification structure of the welds consisted of the cellular and equiaxed dendrites. The creep rupture lives of the two welds were almost the same, and they were reduced by a factor of about two compared to the base metal. Moreover, the rupture elongation of the welds was lower than that of the base metal. Creep damage was observed in the ``parting`` region of the welds and in the heat-affected zone (HAZ), respectively. Final creep fracture occurred in the ``parting`` region of the welds. (orig.).
1995-12-01
International Nuclear Information System (INIS)
AISI 316L stainless steel was welded by the electron beam (EB) and laser techniques. Microstructural characteristics, hardness profile, creep rupture properties and creep damage of the welds were investigated. Fully austenitic microstructure was obtained in the two welds. The solidification structure of the welds consisted of the cellular and equiaxed dendrites. The creep rupture lives of the two welds were almost the same, and they were reduced by a factor of about two compared to the base metal. Moreover, the rupture elongation of the welds was lower than that of the base metal. Creep damage was observed in the ''parting'' region of the welds and in the heat-affected zone (HAZ), respectively. Final creep fracture occurred in the ''parting'' region of the welds. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Laser welding of AISI 904 L super austenitic stainless steel using a diffusion cooled slab 3.5kW CO2 laser and employing two different shielding gases, namely argon and helium, was carried out. The laser weld bead profile depends on various parameters such as beam power (BP), travel speed (TS) and focal position (FP) of the laser spot. These parameters have to be selected suitably to obtain the desirable output. The cross sectioned area of the bead profiles measured using an optical microscope to determine the bead width and depth of penetration. X-ray diffraction used for phase identification confirmed that the weld structure was fully austenitic and dendritic. Hardness was observed to increase in the weld bead with respect to the parent metal and it was related to the microstructural ref...
2010-01-01
Making Simple Sentences Hard: Verb Bias Effects in Simple Direct Object Sentences
Constraint-based lexical models of language processing assume that readers resolve temporary ambiguities by relying on a variety of cues, including particular knowledge of how verbs combine with nouns. Previous experiments have demonstrated verb bias effects only in structurally complex sentences, and have been criticized on the grounds that such effects could be due to a rapid reanalysis stage in a two-stage modular processing system. In a self-paced reading experiment and an eyetracking experiment, we demonstrate verb bias effects in sentences with simple structures that should require no reanalysis, and thus provide evidence that the combinatorial properties of individual words influence the earliest stages of sentence comprehension. (Contains 4 figures and 12 tables.)
2009-04-01
Laser Assisted Emittance Exchange: Downsizing the X-ray Free Electron Laser
Energy Technology Data Exchange (ETDEWEB)
A technique is proposed to generate electron beam with ultralow transverse emittance through laser assisted transverse-to-longitudinal emittance exchange. In the scheme a laser operating in the TEM10 mode is used to interact with the electron beam in a dispersive region and to initiate the emittance exchange. It is shown that with the proposed technique one can significantly downsize an x-ray free electron laser (FEL), which may greatly extend the availability of these light sources. A hard x-ray FEL operating at 1.5 {angstrom} with a saturation length within 30 meters using a 3.8 GeV electron beam is shown to be practically feasible.
2009-12-11
Energy Technology Data Exchange (ETDEWEB)
The influence of common welding defects such as internal under-cut, incomplete penetration of the root bead, internal concavity and hollow bead have been evaluated in a sour environment. Tests were performed on samples cut from actual pipeline welds. The individual defects were subjected to slow strain rate testing. The samples were then examined by metallography, scanning electron microscopy, and hardness testing. It was established that a threshold stress intensity exists for sulphide stress cracking. The test results were compared to those obtained from samples of the weld and pipe which did not contain any defects. This comparison indicated that the metallurgical variations associated with the presence of a weld are the main factor for sulphide stress cracking rather than any specific defects or geometry. 5 tabs., 9 figs.
1992-12-31
Is Gold Really Softer than Silver? HSAB Principle Revisited
Energy Technology Data Exchange (ETDEWEB)
A detailed comparison of the softness of gold and silver has been reported in the light of hard soft acid base (HSAB) principle. Gold and silver nanoparticles in organic media (i.e., organosol) have been exploited individually to establish the principle. Sulfur and nitrogen were employed as soft and borderline donating atoms to examine the metal-ligand interactions. In this regard, thiols and amines have been considered as interacting ligands with sulfur and nitrogen donor atoms respectively. The stronger affinity of gold towards softer sulfur donor as compared to nitrogen and conversely a reasonable interaction of silver nanoparticles with both the atoms authenticate the softer nature of gold nanoparticle as compared to silver one.
2006-02-15
Ion nitriding; Proceedings of the International Conference, Cleveland, OH, Sept. 15-17, 1986
Energy Technology Data Exchange (ETDEWEB)
The present conference discusses plasma-assisted surface coating/modification processes, the applications to date of ion nitriding, the effects of nitrogen on metal surfaces, ion nitriding mechanisms in Cr, Al and Cr + Al-containing 1040 steel, ion nitriding of Al and its alloys, life enhancement for forging dies, novel anode plasma nitriding developments, and a comparative study of the pulsed and dc ion-nitriding behavior in specimens with blind holes. Also discussed are the influence of heating method on ion nitriding, surface hardening of marage steels by ion nitriding without core hardness reduction, plasma nitriding of nodular cast iron sput gears, NbN composites for superconductors, the carburization of tungsten in a glow discharge methane plasma, economic considerations concerning plasma nitriding, and the corrosion properties obtained by ion nitriding.
1987-01-01
International Nuclear Information System (INIS)
The condition for obtaining a calorimetric response linear with energy for hadronic showers and an energy resolution that improves as the incident energy increases is the equalization of the electromagnetic (e) and the hadronic (#pi#) signal responses. This equalization is obtained by exploiting a local hardening effect realized through the insertion of low-Z thin plates between the high-Z absorbers and the active material in a hadronic calorimeter with silicon readout. This effect, which allows the reduction of the calorimeter response to the electromagnetic component of the incoming hadronic showers, has been investigated for different low-Z materials. The relevance of some aspects of this study to the radiation hardness of the calorimeters is also addressed. (orig.).
Investigation of light elements in nitrided steel using elastic backscattering analysis
International Nuclear Information System (INIS)
This work describes the ability of ion beam analysis techniques IBA to simultaneously determine the concentration and the possible depth profile of some light elements, such as carbon, oxygen and nitrogen, in matrices of high atomic number Z, such as stainless steel materials. In fact, the nitriding process of some materials has the potential to improve their tribological and mechanical properties and to offer various advantages as compared with other methods used in the modification of surfaces. Gas and Plasma nitriding were applied to certain types of steel, such as AISI-304 and H-13 which are commonly used in the industry, in order to improve their hardness and their surface corrosion resistance. The improvement was correlated with the depth profile of N and the consequent structure variations. More specifically, non-Rutherford elastic backscattering (alpha, alpha) at 5 MeV was performed on different samples, before and after nitriding, in order to determine the ...
2006-08-01
Investigation into some tribological properties of plasma nitrided hot-worked tool steel AISI H11
Energy Technology Data Exchange (ETDEWEB)
Interest in the tribological properties of plasma nitriding has increased substantially over the past years because plasma nitriding provides a high nitride depth and improved hard facing. The present study examines the tribological properties of AISI H11 plasma nitrided, hot-worked steel. Different nitriding temperatures and durations were considered. Characterization of the composite structures was investigated with wear tests, x-ray diffraction (XRD) analysis, scanning electron microscopy (SEM), and microhardness tests. The depth profile of the nitrided zone was measured using the nuclear reaction analysis (NRA) technique. Plasma nitriding affected the microhardness, wear properties, and morphology considerably. Increase in process temperature increased the nitride zone depth.
1996-04-01
Investigation and analytical use of rare earth ionic associates with benzilic acid and rhodamine B
International Nuclear Information System (INIS)
Ions of rare earth elements (r.e.e.) have been found to form with benzilic acid and rhodamine B precipitates hardly soluble in water and extractable by toluene. The conditions of La and Pr determination by extraction-spectrophotometry method are studied. Relative square deviation does not exceed 0.027 and 0.034 respectively. The method can be used for determination of other cerium sub-group r.e.e. in their salts and cannot be employed for determination of lighter r.e.e. in the presence of heavier r.e.e., because the latter form low soluble precipitates capturing the r.e.e. situated in the beginninq of the r.e.e. series.
1977-01-01
Integrated knowledge management in networks; Integriertes Wissensmanagement in Netzwerken
Energy Technology Data Exchange (ETDEWEB)
Knowledge is a success factor for globally acting company networks as a. o. the aim-oriented knowledge transfer between partners is an essential condition for a successful cooperation. Several network specific problems impede however an efficient and effective knowledge management; e.g. the transfer of competition relevant data is a high sensitive theme. The authors describe how a relevant method can be selected, adapted and implemented to the application-specific boundary conditions. They integrate existing attempts processes and methods to establish an effective knowledge development and an efficient knowledge transfer in the network and take into account ''hard'' (IT-technical-oriented solution approaches) as also ''soft'' factors (e.g. cultural and personal aspects). So the authors present unified instruments for an integrated knowledge management in networks. (GL)
2007-07-01
Improvement of the fatigue strength of AISI 4140 steel by an ion nitriding process
Energy Technology Data Exchange (ETDEWEB)
The influence of plasma nitriding on the fatigue behaviour of AISI 4140 low-alloy steel was investigated under varying process conditions of temperature (500-600 C), time (1-12 h), heat treatment before ion nitriding (quenched and tempered, normalized) and gas mixture (50% H{sub 2}-50% N{sub 2}). A rotating bending fatigue machine was used to determine the fatigue strength. It was found that the plasma nitriding improves the fatigue strength and increases the fatigue limit depending on the surface hardness of the case depth. The microstructure of surface and diffusion layers was examined by optical microscopy. The fracture surface of specimens and the origin of fatigue cracks were observed by scanning electron microscopy.
1995-06-01
Hydrogen-oxygen PEM regenerative fuel cell development at Nasa Glenn Research Center
British Library Electronic Table of Contents (United Kingdom)
The closed-cycle hydrogen-oxygen PEM regenerative fuel cell (RFC) at Nasa Glenn Research Center has successfully demonstrated closed-cycle operation at rated power for multiple charge/discharge cycles. During the charge cycle the RFC has absorbed input electrical power simulating a solar day cycle ranging from zero to 15 kWe peak, and delivered steady 5 kWe output power for periods exceeding 8 h. Orderly transitions from charge to discharge mode, and return to charging after full discharge, have been accomplished without incident. The RFC is beginning to demonstrate its potential as an energy storage device for aerospace solar power systems such as solar electric aircraft, lunar and planetary surface installations - any airless environment where minimum system weight is critical. This hard...
2006-01-01
Energy Technology Data Exchange (ETDEWEB)
The tests reported were part of the DOE Geothermal Reservoir Well Stimulation Program. This East Mesa (Imperial Valley, CA) well was successfully stimulated with two fracture treatments, a dendritic fracture and a planar fracture. The natural flow production of the well increased 114 percent, to 197,900 lb/hr. These tests were among the few successful attempts of this program to increase flow from geothermal production wells. The general belief is that these tests worked OK primarily because the formation was sedimentary rock (similar to rock in most oil and gas wells that have been stimulated successfully. Similar tests in geothermal hard rock reservoirs did not work very well. (DJE 2005)
1982-02-01
High-temperature property data: Ferrous alloys
Energy Technology Data Exchange (ETDEWEB)
In this book over 250 alloys are organized by AISI number into 10 major sections: Irons, Carbon Steels, Alloy Steels, Low Alloy Constructional Steels, Ultra High Strength Steels, Tool Steels, Maraging Steels, Wrought Stainless Steels, Heat Resistnat Casting Alloys, and Iron Based Rought Superalloys. Each alloy record lists the designation, specifications, UNS number, composition, product forms and a comment on the high-temperature properties and applications. Referenced data is then given for physical properties such as density, specific heat, thermal conductivity, thermal expansion, electrical conductivity, Poisson's ratio, moduli of elasticity and rigidity, etc. Mechanical properties follow, and include tensile properties, shearing and bearing properties, impact properties, creep, stress rupture and stress relaxation and fatigue properties. The last part of the alloy record gives other effects of temperature, such as hot hardness, corrosion, and growth.
1987-01-01
British Library Electronic Table of Contents (United Kingdom)
Determination of the maximum temperature and temperature distribution along the rake face of the cutting tool is of particular importance because of its controlling influence on tool life, as well as, the quality of the machined part. Numerous attempts have been made to approach the problem with different methods including experimental, analytical and numerical analysis. Although considerable research effort has been made on the thermal problem in metal cutting, there is hardly a consensus on the basics principles. The unique tribological contact phenomenon, which occur in metal cutting is highly localized and non-linear, and occurs at high temperatures, high pressures and high strains. This has made it extremely difficult to predict in a precise manner or even assess the performance of va...
2006-01-01
Greenhouse gas emission inventory based on full energy chain analysis
International Nuclear Information System (INIS)
Methodology, characteristics, features and results obtained for greenhouse gases within the recent Swiss LCA study 'Environmental Life-Cycle Inventories of Energy Systems' are presented. The focus of the study is on existing average Full Energy Chains (FENCHs) in the electricity generation mixes in Europe and in Switzerland. The systems, including coal (hard coal and lignite), oil, natural gas, nuclear and hydro, are discussed one by one as well as part of the electricity mixes. Photovoltaic systems are covered separately since they are not included in the electricity mixes. A sensitivity analysis on methane leakage during long-range transport via pipeline is shown. Whilst within the current study emissions are not attributed to specific countries, the main sectors contributing to the total GHGs emissions calculated for the various FENCHs are specified. (author). 10 refs, 10 figs, 9 tabs.
1996-07-01
The Goldstone-Brueckner perturbation theory is extended to incorporate in a simple way correlations associated with large amplitude collective motions in nuclei. The new energy expansion making use of non-orthogonal vacua still allows to remove the divergences originating from the hard-core of the bare interaction. This is done through the definition of a new Brueckner matrix summing generalized Brueckner ladders. At the lowest-order, this formalism motivates variational calculations beyond the mean-field such as the Generator Coordinate Method (GCM) and the Projected Mean-Field Method from a perturbative point of view for the first time. Going to higher orders amounts to incorporate diabatic effects in the GCM and to extend the projection technique from product states to well-defined correlated states.
2003-01-01
British Library Electronic Table of Contents (United Kingdom)
In this paper we demonstrate the capabilities of our ArcGIS-based software development that includes an adapted database system and a GIS tool for storage, combined analysis and visualization of leveling data and interferometric synthetic aperture radar (SAR) deformation measurements. Preprocessed remote sensing image data are stored with metadata that include all processing routines and parameters. This allows reproduction and traceability of all processing steps. Deformation monitoring is supported through data searching and selection based on a variety of criteria. A methods toolbox allows spatio-temporal analyses for points, lines and areas (e.g. subsidence basins) in a graphical manner.
2011-01-01
Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe
International Nuclear Information System (INIS)
To evaluate safety of horizontal steam generator used in passive safety system, it is needed to make clear flooding characteristics in U bend pipe. In this study, two-phase flow experiment in a horizontal U bend pipe was carried out to make clear the influence of the length of horizontal pipe and the radius of U bend. Flooding in the U bend pipe was observed in the condition of lower gas or liquid volumetric flux than that in the horizontal pipe or the vertical pipe. Flooding and carry-up in the U bend pipe is hardly change with increasing the length between the water inlet and the U bend, but greatly related with the length from the water inlet to the lower tank and the shape of the U bend inlet. (author).
1994-05-01
Energy Technology Data Exchange (ETDEWEB)
In order to develop the filler metal for Hastelloy alloy XR structure with thick wall, the weldability and high temperature strength properties of Hastelloy alloy XR weldment were investigated using the filler metals, which were alloy-designed on the basis of multiple regression analysis. The former was examined through the chemical analysis in the deposited metal, bend test, FISCO cracking test, optical microscopy and hardness measurement. The latter was investigated by means of tensile and creep test. It was found from these results that the crack susceptibility in the weldment was apparent to be lowered without degrading the high temperature strength properties. Therefore, it is concluded that these filler metals possess excellent performance as the filler metal for Hastelloy alloy XR structure with thick wall. (author).
1991-11-01
Feynman graphs and generalized eikonal approach to high energy knock-out processes
International Nuclear Information System (INIS)
The cross section of hard semiexclusive A(e,e"'N)(A-1) reactions for fixed missing energy and momentum is calculated within the eikonal approximation. Relativistic dynamics and kinematics of high energy processes are unambiguously accounted for by using the analysis of appropriate Feynman diagrams. A significant dependence of the final state interactions on the missing energy is found, which is important for interpretation of forthcoming color transparency experiments. A new, more stringent kinematic restriction on the region where the contribution of short-range nucleon correlations is enhanced in semiexclusive knock-out processes is derived. It is also demonstrated that the use of light-cone variables leads to a considerable simplification of the description of high energy knock-out reactions. copyright 1997 The American Physical Society.
Expert judgement of uncertainties in modelling emergency actions after nuclear accidents
Energy Technology Data Exchange (ETDEWEB)
Sheltering, evacuation and distribution of stable iodine tablets are considered to be major early emergency actions aiming at diminishing the consequences after a release of radioactive materials from nuclear power plants into the air. Whether in real situations emergency managers will act accordingly is hard to predict. Uncertainties associated with these decisions are termed 'volitional' uncertainties. These uncertainties, however, cannot be assessed by expert judgements as they express the decision at stake in an emergency situation. Uncertainties on the times to implement countermeasures and on the times for the general population to respond to these measures can be assessed by experts, as they represent 'lack-of-knowledge' uncertainties. This paper describes the difference in approach of both types of uncertainties and shows the results of expert judgements on the latter type of uncertainties in early emergency actions. Ten ...
2000-07-01
Endurance of cultured pearls irradiated with gamma-rays
International Nuclear Information System (INIS)
Pearls change their color to grey by #gamma#-ray irradiation. Grey densities were determined from darkness of pearl nuclei and thickness of the pearl layers. The densities are independent of both diameters of nuclei and pearls. The fading rate increases with increasing storage temperature. The rate of fading for irradiated pearls is lower than that for natural blue pearls. Comparison of photomicrographs (x 12) for pearls irradiated and then stored at room temperature for about 6 years revealed that their surfaces are not substantially different from the surfaces of unirradiated cultured pearls, indicating that #gamma# irradiation hardly gives rise to deterioration. #gamma#-Ray irradiation is a technique for coloration of pearls. Irradiated blue pearls seem to have resistivity to fading and to deterioration of the surface, if pearls have been irradiated properly. (author).
Electrodeposition and characterization of Ni-Co/SiC nanocomposite coatings
British Library Electronic Table of Contents (United Kingdom)
Ni-Co/SiC nanocomposite coatings were electrodeposited in a modified watt type of Ni-Co bath containing 20nm SiC particles to be codeposited. Potentiodynamic polarization tests were conducted to study the effect of the SiC particulates on the electrodeposition of Ni and Co. Scanning electron microscopy was used to assess the morphology of the Ni-Co alloy and Ni-Co/SiC nanocomposite coatings. The distribution of the particulates in the matrix was considered by means of transmission electron microscopy. Applying nanomechanical testing instruments coupled to atomic force microscopy, mechanical properties of the alloy and composite coatings were studied and compared. The presence of 11vol.% SiC in the Ni-Co matrix increased hardness more than 60%. The average depth of scratch in the mentioned ...
2011-01-01
Effects of stress on radiation hardening and microstructural evolution in A533B steel
British Library Electronic Table of Contents (United Kingdom)
Bent specimens of A533B steel (0.16wt% Cu) were irradiated at 290degreeC to 1dpa with 6.4MeV Fe3+ ions. Calculated tensile stresses at the irradiated surface were set to 0, 250, 500 and 750MPa. The specimens were subjected to hardness measurements, transmission electron microscopy (TEM) observations and three-dimensional atom probe (3DAP) analysis. The radiation-induced hardening decreased with increasing stress to 500MPa which was near the yield strength. TEM and 3DAP results showed that well-defined dislocation loops and solute clusters were formed. The diameter of dislocation loops increased and the number density decreased when the stress was applied, whereas the diameter and number density of solute clusters decreased. The hardening was mainly attributed to solute cluster formation. A...
2010-01-01
Effective numbers of multiquark fluctons in atomic nuclei
International Nuclear Information System (INIS)
A technique is developed for calculation of the total weight of the quark clusters-fluctons in atomic nuclei. The microscopical proof of Blochintsev formula is carried out and its refinement is obtained (spin-charge and quark factors enter the formula). It is shown that high values of the correlation radius (R_c #approx =# 0.75 fm or 1.0 fm in various papers) obtained from the experimental data making use of the above formula correspond to internucleon distances in flucton of 0.3-0.4 fm, which is by a factor of #approx# 2.5 lower. This means that the flucton hardness is due to free manifestation of hidden color at those distances (the appropriate probabilities are presented).
Effect on substrate-film adherence of TiN film enhanced plasma nitriding
International Nuclear Information System (INIS)
The combined process of low temperature plasma nitriding and TiN film deposition was realized on the plasma-assisted vacuum arc plating set. The process of plasma nitriding can be done below 200 degree C. The low temperature plasma nitriding and TiN film deposition was realized on the same device. By the SEM analysis of the plating structure, low hardness grads from the substrate to the film was obtained, and it was found that the mixed nitride plating formed at the interface between the substrate and the film. The quantitative measurement of substrate-film adherence showed that the adherence was improved notably by using the process. The adherence between film and substrate can reach to 59.6 MPa without the bias voltage supplying
2002-01-01
International Nuclear Information System (INIS)
Recent research carried out in laboratories showed that Saddle field neutral fast atom beam source is a promising method for nitriding of stainless steel. In the present work, the effect of treatment time on the microstructural and mechanical properties of plasma-nitrided stainless steel sample was investigated by this new method. Plasma nitriding was carried out at 420 deg. C and at a pressure of 0.1 Pa for a time range of 1 to 12 h. SEM-EDX, microhardness tests, optical microscopy and X-ray diffraction (XRD) were used to evaluate the mechanical and structural properties of the nitrided layer. It was found that nitriding time has a pronounced effect on the structural and mechanical properties of low-temperature plasma-nitrided samples and produced a precipitation-free thin hard nitrided layer within a short processing time.
2006-09-25
Effect of the final coking temperature on the strength properties of molded coke
Energy Technology Data Exchange (ETDEWEB)
Increasing the end coking temperature to 850 C has a marked effect on both the physico-mechanical and physico-chemical properties of formed coke, and although subsequent rise in temperature leaves the mechanical strength largely unaltered, it appears to increase hardness, real density and conductivity at the expense of diminished reactivity. Formed coke strength can be slightly improved by extending the coking time by an isothermal residence period at end temperatures of 650 and 750 C. Structural change in the formed coke tends to concentrate in the 450 to 650 C range where carbon increases by 6.98-8.27% as compared with hydrogen and oxygen which fall 2.40-3.53 and 3.50-4.62% respectively.
1985-01-01
Effect of the final coking temperature on the strength properties of formed coke
Energy Technology Data Exchange (ETDEWEB)
Effect of final temperature and duration of coking on the properties of formed coke from weakly-caking Donetsk and Kuznetsk coals was studied. An increase of the final temperature to 850 C produced significant changes in the mechanical and chemical properties of the coke. Increasing the temperature beyond this point did not affect the mechanical strength significantly, but did increase hardness, real density and electroconductivity of the coke and decrease reactivity. Increasing the period of coking at final temperatures in the 650 and 750 C range, produced insignificant hardening of the formed coke. An objective evaluation of the effect of final temperature can be performed by a series of tests which characterize the resistivity of the formed coke to impact and abrasion and the fine structure of the matter in coke. 9 references.
1985-01-01
Energy Technology Data Exchange (ETDEWEB)
The study abstracted aims at analyzing the economic effects of energy policies using simulations. Emphasis is on assessing the effects of decisions in favour of an expanding electric power industry based on nuclear energy and hard coal. The study discusses alternative assumptions concerning the cost involved, pollution abatement measures, shutdown and dismantling costs etc. Input-output analyses make the simulation model a consistent vehicle. Besides, the model in question is characterized by its explaining the investment demand of the different sectors by referring to the continuous annual development of innovative technologies.
1986-01-01
Development of titanium diboride coatings deposited by PACVD
Energy Technology Data Exchange (ETDEWEB)
TiB{sub 2} appears to be a promising material for the wear protection in various tribological systems, e.g. the diecasting of Al. This study focuses on the development of titanium boride coatings deposited by PACVD, a deposition method which is most suitable for the coating of substrates with complex shapes. All layers analysed are very smooth and exhibit a quasi-amorphous fracture surface. XRD and TEM analysis indicate a nanocrystalline structure with grain sizes in the order of 2 nm. The diffraction patterns can well be correlated to titanium diboride. WDS reveals an over stoichiometric B/Ti ratio. The layer hardness reaches the value of 33 GPa and the critical load in scratch tests rises to 35 N. Neither 100Cr6 nor Al as a counterpart in pin-on-disk tests leads to wear of the coating. (orig.)
2000-09-01
Detection of irradiated chicken by ESR spectroscopy of bone
Energy Technology Data Exchange (ETDEWEB)
Ionizing radiation has been used to treat poultry to remove harmful microorganisms, mainly Salmonella, which contaminates chicken, goose and other fresh and frozen poultry. This microorganism is sensitive to low dose radiation. Thus, irradiating these foods with doses between 1 to 7 kGy results in a large reduction of bacteria. Since it is necessary to determine whether irradiation has occurred and to what extend, this work studied the signal produced by ionizing radiation within the hard crystalline matrix of chicken`s bone to establish a control method. Chicken`s drumsticks were irradiated and bones separated from flesh were lyophilized and milled. ESR spectrum was then obtained. The ESR signal increased linearly with dose over the range 0.25 to 8.0 kGy. Free radicals evaluated during 30 days after irradiation showed stable in this period. (Author).
1995-10-01
Design concept for radiation hardening of low power and low voltage dynamic memories
International Nuclear Information System (INIS)
A radiation hard low power, low voltage dynamic memory is obtained by the use of a dummy cell concept. Compared to conventional dummy cell concepts, this concept applies a fully sized dummy cell. By optimizing the dummy cell precharge voltage for 5 V and 3 V operation and the timing of the dummy word-line, the overall soft error rate (SER) of the chip is improved by 2 orders of magnitude. An additional improvement of 1 order of magnitude is possible for 3 V operation by adjusting substrate bias and cell plate voltage. The results are verified by an accelerated SER measurement with a radium 226 source and an additional field soft error study.
Database for thermal and mechanical properties of REBaCuO bulks
International Nuclear Information System (INIS)
The thermal properties (thermal conductivity, thermal diffusivity, thermoelectric power, thermal dilatation, etc.) and the mechanical properties (Young's modulus, strength, hardness, fracture toughness, etc.) have been measured at low temperatures (4-300K) and under a high magnetic field (0-10T) for about 50 REBaCuO bulks (RE=Y, Gd, Nd, Sm, Dy, etc.). We have constructed the database of these properties and opened it on the Web site (thermal properties: http://ikebehp.mat.iwate-u.ac.jp/database.html and mechanical properties: http://paris.mech.iwate-u.ac.jp/sc-bulk/database.html). The influence of the species of RE ions, the content, size and dispersion of the RE211 (or Nd422) phase and Ag particles and the defects distribution on these properties is characterized.
2005-10-01
Creating bulk nanocrystalline metal.
Energy Technology Data Exchange (ETDEWEB)
Nanocrystalline and nanostructured materials offer unique microstructure-dependent properties that are superior to coarse-grained materials. These materials have been shown to have very high hardness, strength, and wear resistance. However, most current methods of producing nanostructured materials in weapons-relevant materials create powdered metal that must be consolidated into bulk form to be useful. Conventional consolidation methods are not appropriate due to the need to maintain the nanocrystalline structure. This research investigated new ways of creating nanocrystalline material, new methods of consolidating nanocrystalline material, and an analysis of these different methods of creation and consolidation to evaluate their applicability to mesoscale weapons applications where part features are often under 100 {micro}m wide and the material's microstructure must be very small to give homogeneous properties across the feature.
2008-10-01
Couple stress fluid improve rub-impact rotor-bearing system - Nonlinear dynamic analysis
British Library Electronic Table of Contents (United Kingdom)
This study performs a dynamic analysis of the rub-impact rotor supported by two couple stress fluid film journal bearings. The strong nonlinear couple stress fluid film force, nonlinear rub-impact force and nonlinear suspension (hard spring) are presented and coupled together in this study. The displacements in the horizontal and vertical directions are considered for various non-dimensional speed ratios. The numerical results show that the dynamic behaviors of the system vary with the dimensionless speed ratios, the dimensionless unbalance parameters and the dimensionless parameter, l*. Inclusive of the periodic, sub-harmonic, quasi-periodic and chaotic motions are found in this analysis. The results of this study contribute to a further understanding of the nonlinear dynamics of a rotor-...
2010-01-01
Cosmological Questions for the European Southern Observatory Very Large Telescope
The next decade promises an observational revolution which will change cosmology forever. The precise measurement of the angular anisotropy of the cosmic microwave background should specify to a few percent all of the parameters of the cosmological model which effect astrophysics. The growth of structure will then be determined (but not yet observed) until gravitational collapse becomes highly non-linear and stars, galaxies and active galactic nuclei (AGN) form. These processes are hard to model with basic physics because they are complex and allow a rich variety of expression. Instead observations will determine when the first stars and quasars formed, and how and when galaxies assembled. If we can reconcile the numerous contradictions which characterize the subject today, cosmology will become a mature subject, founded on the agreement between detailed, inclusive and realistic models, which make precise predictions, and the wealth of new data which will come from ...
1996-01-01
Constitutional examinations in the system Fe-Al-Zr; Konstitutionsuntersuchungen im System Fe-Al-Zr
Energy Technology Data Exchange (ETDEWEB)
Two isothermal sections were prepared at 1000 and 1150 C showing the low-Zr phases of the system Fe-Al-Zr. The phase equilibria were determined by means of X-ray powder diffractometry and electron beam microanalysis. For initial characterisation of mechanical properties, hardness values are determined and added to the tabulated data. (orig./MM) [German] Es werden am Fe-Al-Zr-System zwei isotherme Schnitte durch den zirkoniumarmen Teil des Systems bei 1000 und 1150 C erstellt. Die auftretenden Phasengleichgewichte werden mit Hilfe der Roentgenpulverdiffraktometrie und Elektronenstrahlmikroanalyse aufgeklaert. Zusaetzlich werden zur ersten Charakterisierung der mechanischen Eigenschaften Haertewerte bestimmt.
1999-07-01
British Library Electronic Table of Contents (United Kingdom)
Mechanobiological theories have been introduced to illustrate the interaction between biology and the local mechanical environment during bone healing. Although several theories have been proposed, a quantitative validation using histomorphometric data is still missing. In this study, in vivo histological data based on an ovine animal experiment was quantified and used to validate bone healing simulations focussing on the endochondral ossification process. The bone formation at different callus regions (periosteal and endosteal bone at the medial and lateral side) was analyzed from in vivo data and quantitatively compared with in silico results. A histomorphometric difference was found in medial and lateral hard callus formation 3 weeks after osteotomy. However, the same amount of new bone...
2011-01-01
Coloring of cultured pearls by gamma-rays irradiation
International Nuclear Information System (INIS)
Changing cream pearls into bluish-grey by #gamma# ray irradiation is a technique in coloring of pearls. Irradiated pearls are similar in color to cultured blue pearls. The pearl layers hardly change their color but the nuclei change into dark brown by irradiation. Visible light (500 - 700 nm) penetrating the pearl layer is absorbed by dark brown nucleus. The intensity of reflecting light between 400 and 500 nm at pearl surface, therefore, becomes stronger than that between 500 and 700 nm; therefore color of irradiated pearls look bluish-grey. The density of bluish-grey color increases with increasing absorbed doses, but their luster at surface diminishes owing to the deterioration of the pearl layer by prolonged irradiation; high doses irradiation should be avoided. Irradiated pearls show no substantial fading of their color in a year and the rate of the fading is found to be lower than that for cultured blue pearls. (author).
Close binaries containing Supermassive Black Holes
British Library Electronic Table of Contents (United Kingdom)
We consider the evolution of binary systems formed by a Supermassive Black Hole (SMBH) residing in the center of a galaxy or a globular cluster and a star in its immediate vicinity. The star is assumed to fill its Roche lobe, and the SMBH accretes primarily the matter of this star. The evolution of such a system is mainly determined by the same processes as for an ordinary binary. The main differences are that the donor star is irradiated by hard radiation emitted during accretion onto the SMBH; in a detached system, nearly all the donor wind is captured by the black hole, which strongly affects the evolution of the semi-major axis; it is not possible for companions of the most massive SMBHs to fill their Roche lobes, since the corresponding orbital separations are smaller than the radius ...
2010-01-01
British Library Electronic Table of Contents (United Kingdom)
The determination of residual stress (RS) in case-hardened steel gear truck synchronisers coated with thermal sprayed molybdenum was carried out using neutron and synchrotron X-ray diffraction. Two samples with different coating thicknesses (about 120 ?m and 1.4 mm) and different steel substrates (16MnCr5 and SAE4140, respectively) were investigated. Microanalysis revealed substantial porosity in both samples and some debonding was observed between the thin coating and the substrate. The bulk hardness of the SAE 4140 proved to be much higher than the 16MnCr5 and the surface case-hardening increased it by a further 20%. The full three-dimensional stress depth-profile was determined by neutron diffraction (ND) in both the coatings and the substrates, while synchrotron radiation allowed a dep...
2006-01-01
Characterising and reducing seizure wear of inconel and incoloy superalloys in a sliding contact
British Library Electronic Table of Contents (United Kingdom)
Superalloys, such as Inconels and Incoloys, are extensively used where high strength is a requirement. However, where these materials are required to slide against one another, particularly with poor or no lubrication, high friction levels and seizure are commonly seen to occur, which can cause component failure. In this work seizure characteristics of three superalloys (Inconel 718 and Incoloys 945 and 945X) were investigated, uncoated, coated with Armoloy (a hard, thin, dense chrome coating with a micro-nodular surface texture) and plasma nitrided in dry sliding conditions. A rig purpose built for initiating seizure was used. It involves sliding a ball against a disc at constant speed while the load is increased. Tests are designed to last less than one rotation so that the wear scar can...
2011-01-01
Change from polycrystalline to amorphous growth in sputtered CoZr/Cu multilayers
International Nuclear Information System (INIS)
The authors present an investigation of structural changes occurring in bilayer stacks with crystalline columnar growth when one of the layers is substituted by layers known to grow amorphous. In Co/Cu multilayers the Co layers were substituted by CoZr layers of varying Zr content and layer thickness. Structural characterization was performed by transmission electron microscopy (TEM). They show that the amorphization of the CoZr layers leading to a destruction of the columnar growth depends both on the Zr content and on the thickness of the CoZr layers. Additionally a change to textured growth with a normal to the substrate occurs with increasing Zr content. They explain their observations by a simple picture based on the hard sphere model.
1997-04-04
Basic mechanisms of radiation effects in the natural space radiation environment
Energy Technology Data Exchange (ETDEWEB)
Four general topics are covered in respect to the natural space radiation environment: (1) particles trapped by the earth`s magnetic field, (2) cosmic rays, (3) radiation environment inside a spacecraft, (4) laboratory radiation sources. The interaction of radiation with materials is described by ionization effects and displacement effects. Total-dose effects on MOS devices is discussed with respect to: measurement techniques, electron-hole yield, hole transport, oxide traps, interface traps, border traps, device properties, case studies and special concerns for commercial devices. Other device types considered for total-dose effects are SOI devices and nitrided oxide devices. Lastly, single event phenomena are discussed with respect to charge collection mechanisms and hard errors. (GHH)
1994-06-01
AquaMagna Water Conditioner and Descaler
...AquaMagna Water Conditioner and Descaler OCETA Environmental Technology & Business Profiles AQUAMAGNA WATER CONDITIONER AND DESCALER CAT. #03-018 CONTACT: Magna-Tek ...removal high-strength ceramic magnet no energy input The AquaMagna Water Conditioner and Descaler is a non-chemical method of water treatment. The technology uses ... Figure 1: The AquaMagna Water Conditioner and Descaler PROCESS/ PRODUCT APPLICATION: hard water domestic water process water reverse osmosis heat exchangers cooling ... For once-through or recirculating heating or cooling equipment, the AquaMagna descaler improves thermal efficiencies and reduces downtime. Figure 2 illustrates a cross-section ...
All sliding element journal bearing rock bit
Energy Technology Data Exchange (ETDEWEB)
For years rock bit performance has been progressively improved by many innovative changes to the design of both the bit cutting structure and the bearing. The changes have offered increased footage per bit and reduced cost per foot of hole through longer bit life and/or faster penetration rate. Efforts to assist the industry in drilling deeper thru hard abrasive rocks such as cherts of West Texas, conglomerated of the Rockies and bromides of Oklahoma led to a major breakthrough in rock bit design - the development of the tungsten carbide cutting structure. When properly applied the bit far exceeded that of the non-sealed ball and roller bearing being used at the time. The bearing failure mode was one of severe race spalling and abrasive wear influenced by the drilling fluid entering the bearing.
1983-08-01
A small direct injection diesel engine with a swirl nozzle
Energy Technology Data Exchange (ETDEWEB)
A new combustion system for a small direct injection diesel engine has been developed, with a spheroidal cavity and swirl nozzle characterized by weak spray penetration and wide spray angle. This system is intended to realize air-borne mixture formation and good combustion processes over wide operating ranges. In-cylinder observations of the system reveal that droplets are easily bent in the direction of air movement, ignition occurs near the spray tip, and the flame is hard to envelop the spray. In a single cylinder engine of 460 cm/sup 3/ swept volume, the system realizes active diffusion burning and mild premixed burning despite of long ignition delay, and provides low fuel consumption and low smoke emission, especially at low speeds.
1987-01-01
This paper gives a concise overview of evolutionary algorithms for multiobjective optimization. A substantial number of evolutionary computation methods for multiobjective problem solving has been proposed so far, and an attempt of unifying existing approaches is here presented. Based on a fine-grained decomposition and following the main issues of fitness assignment, diversity preservation and elitism, a conceptual global model is proposed and is validated by regarding a number of state-of-the-art algorithms as simple variants of the same structure. The presented model is then incorporated into a general-purpose software framework dedicated to the design and the implementation of evolutionary multiobjective optimization techniques: ParadisEO-MOEO. This package has proven its validity and flexibility by enabling the resolution of many real-world and hard multiobjective optimization problems.
2009-01-01
(#alpha#+#beta#) - Sialon ceramic composites
International Nuclear Information System (INIS)
(#alpha#+#beta#)-SiALON ceramic composites are industrially important materials. Due to their unique chemistry, crystal structure and microstructural features, #alpha#-SiAlON has superior hardness while #beta#-SiALON offers high strength and toughness. The combination of the two phases enables materials engineers to design a ceramic where the physical properties of the composite can be tailored to a particular application. This article presents a general review of the crystal structures, fabrication and properties of the (#alpha#+#beta#)-SiALON composites with special highlights outlining how microstructural tailoring can control the properties of these advanced ceramic alloys. Copyright (1997) Institute of Metals and Materials Australasia Ltd.