WorldWideScience
1

Management of petroleum underground storage tanks at the Hanford Site  

International Nuclear Information System (INIS)

This report represents the timetables, responsible organizations, and methods required to comply with the newly promulgated Washington Administrative Code (WAC) 173-360 Underground Storage Tank (UST) Regulations which became effective December 29, 1990. This report only addresses UST systems that contain nonradioactive material. A total of 84 tanks at the Hanford Site are currently regulated under WAC 173-360. In addition, 32 regulated tanks have been removed as a result of the federally mandated program and the newly implemented state regulations. The majority of the USTs at the Hanford Site are operated by Westinghouse Hanford; however, one is operated by Kaiser Engineers Hanford (KEH) and one by Pacific Northwest Laboratory (PNL).

1991-09-08

2

Hanford tanks initiative plan  

Energy Technology Data Exchange (ETDEWEB)

Abstract: The Hanford Tanks Initiative (HTI) is a five-year project resulting from the technical and financial partnership of the U.S. Department of Energy`s Office of Waste Management (EM-30) and Office of Science and Technology Development (EM-50). The HTI project accelerates activities to gain key technical, cost performance, and regulatory information on two high-level waste tanks. The HTI will provide a basis for design and regulatory decisions affecting the remainder of the Tank Waste Remediation System`s tank waste retrieval Program.

1997-07-01

3

Load requirements for maintaining structural integrity of Hanford single-shell tanks during waste feed delivery and retrieval activities  

Energy Technology Data Exchange (ETDEWEB)

This document provides structural load requirements and their basis for maintaining the structural integrity of the Hanford Single-Shell Tanks during waste feed delivery and retrieval activities. The requirements are based on a review of previous requirements and their basis documents as well as load histories with particular emphasis on the proposed lead transfer feed tanks for the privatized vitrification plant.

1999-09-22

4

Corrosion and failure processes in high-level waste tanks  

Energy Technology Data Exchange (ETDEWEB)

A large amount of radioactive waste has been stored safely at the Savannah River and Hanford sites over the past 46 years. The aim of this report is to review the experimental corrosion studies at Savannah River and Hanford with the intention of identifying the types and rates of corrosion encountered and indicate how these data contribute to tank failure predictions. The compositions of the High-Level Wastes, mild steels used in the construction of the waste tanks and degradation-modes particularly stress corrosion cracking and pitting are discussed. Current concerns at the Hanford Site are highlighted.

1992-11-01

5

Structural acceptance criteria for the evaulation of existing double-shell waste storage tanks located at the Hanford site, Richland, Washington  

Energy Technology Data Exchange (ETDEWEB)

The structural acceptance criteria contained herein for the evaluation of existing underground double-shell waste storage tanks located at the Hanford Site is part of the Life Management/Aging Management Program of the Tank Waste Remediation System. The purpose of the overall life management program is to ensure that confinement of the waste is maintained over the required service life of the tanks. Characterization of the present condition of the tanks, understanding and characterization of potential degradation mechanisms, and development of tank structural acceptance criteria based on previous service and projected use are prerequisites to assessing tank integrity, to projecting the length of tank service, and to developing and applying prudent fixes or repairs. The criteria provided herein summarize the requirements ...

1995-09-01

6

Implementation guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511  

Energy Technology Data Exchange (ETDEWEB)

This report is an Implementation Guide for Hanford Tanks Initiative C-106 heel retrieval contract management HNF-2511 to provide a set of uniform instructions for managing the two contractors selected. The primary objective is to produce the necessary deliverables and services for the HTI project within schedule and budget.

1998-04-17

7

Operational test report integrated system test (ventilation upgrade)  

Energy Technology Data Exchange (ETDEWEB)

Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

1999-10-05

8

Chemical compatibility study of Cooley L18KU, Herculite, and Elephant Mat with Hanford tank waste  

Energy Technology Data Exchange (ETDEWEB)

An independent chemical compatibility review of various wrapping and absorbent/padding materials was conducted to evaluate resistance to chemicals and constituents present in liquid waste from the Hanford underground tanks. These materials will be used to wrap long-length contaminated equipment when such equipment is removed from the tanks and prepared for transportation and subsequent disposal or storage. The materials studied were Cooley L18KU, Herculite, and Elephant Mat. The study concludes that these materials are appropriate for use in this application.

1998-06-23

9

Experience with Aerosol Generation During Rotary Mode Core Sampling in the Hanford Single Shell Waste Tanks  

Energy Technology Data Exchange (ETDEWEB)

This document provides data on aerosol concentrations in tank headspaces, total mass of aerosols in the tank headspace, and mass of aerosols sent to the exhauster during rotary mode core sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based upon operational data and non-destructive assay.

2001-03-23

10

Experience with Aerosol Generation During Rotary Mode Core Sampling in the Hanford Single Shell Waste Tanks  

Energy Technology Data Exchange (ETDEWEB)

This document provides data on aerosol concentrations in tank head spaces, total mass of aerosols in the tank head space and mass of aerosols sent to the exhauster during Rotary Mode Core Sampling from November 1994 through June 1999. A decontamination factor for the RMCS exhauster filter housing is calculated based on operation data.

2000-01-24

11

Characterization of the corrosion behavior of the carbon steel liner in Hanford Site single-shell tanks  

Energy Technology Data Exchange (ETDEWEB)

Six safety initiatives have been identified for accelerating the resolution of waste tank safety issues and closure of unreviewed safety questions. Safety Initiative 5 is to reduce safety and environmental risk from tank leaks. Item d of Safety Initiative 5 is to complete corrosion studies of single-shell tanks to determine failure mechanisms and corrosion control options to minimize further degradation by June 1994. This report has been prepared to fulfill Safety Initiative 5, Item d. The corrosion mechanisms that apply to Hanford Site single-shell tanks are stress corrosion cracking, pitting/crevice corrosion, uniform corrosion, hydrogen embrittlement, and microbiologically influenced corrosion. The corrosion data relevant to the single-shell tanks dates back three decades, when results were obtained from in-situ corrosion coupons in a few single-shell ...

1994-06-01

12

Hanford Waste Management Plan, 1987  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the Hanford Waste Management Plan (HWMP) is to provide an integrated plan for the safe storage, interim management, and disposal of existing waste sites and current and future waste streams at the Hanford Site. The emphasis of this plan is, however, on the disposal of Hanford Site waste. The plans presented in the HWMP are consistent with the preferred alternative which is based on consideration of comments received from the public and agencies on the draft Hanford Defense Waste Environmental Impact Statement (HDW-EIS). Low-level waste was not included in the draft HDW-EIS whereas it is included in this plan. The preferred alternative includes disposal of double-shell tank waste, retrievably stored and newly generated TRU waste, one pre-1970 TRU solid waste site near the Columbia River and encapsulated cesium and strontium waste.

1987-01-01

13

Phase chemistry and radionuclide retention of high level radioactive waste tank sludges  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) has millions of gallons of high level nuclear waste stored in underground tanks at Hanford, Washington and Savannah River, South Carolina. These tanks will eventually be emptied and decommissioned. This will leave a residue of sludge adhering to the interior tank surfaces that may contaminate groundwaters with radionuclides and RCRA metals. Experimentation on such sludges is both dangerous and prohibitively expensive so there is a great advantage to developing artificial sludges. The US DOE Environmental Management Science Program (EMSP) has funded a program to investigate the feasibility of developing such materials. The following text reports on the success of this program, and suggests that much of the radioisotope inventory left in a tank will not move out into the surrounding environment. Ultimately, such studies may play a significant role in ...

2000-05-19

14

Destruction of organic chemicals in Hanford HLW tanks by radiolytic and chemical aging  

International Nuclear Information System (INIS)

The underground storage tanks at the Hanford Complex contain mixed wastes generated over many years from plutonium production and recovery processes. The chemical changes of the organic materials used in the extraction processes and disposed to the tanks have a direct bearing on several specific safety issues, including potential energy releases from these tanks. This paper will give details of a study that is directed towards elucidating thermal and radiological decomposition mechanisms and products of the organic contents of the tanks. The study is being conducted in two parts. The first part, an aging study, will determine kinetics and products of the degradation of a simulated waste subjected to #gamma#-radiation from an external source. Although the simulant will not contain radioactive elements, it will contain other representative inorganic compounds and the primary organic ...

1994-08-21

15

Phase Chemistry of Tank Sludge Residual Components  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) has millions of gallons of high level nuclear waste stored in underground tanks at Hanford, Washington and Savannah River, South Carolina. These tanks will eventually be emptied and decommissioned. This will leave a residue of sludge adhering to the interior tank surfaces that may contaminate nearby groundwaters with radionuclides and RCRA metals. Performance assessment (PA) calculations must be carried out prior to closing the tanks. This requires developing radionuclide release models from the sludges so that the PA calculations can be based on credible source terms. These efforts continued to be hindered by uncertainties regarding the actual nature of the tank contents and the distribution of radionuclides among the various phases. In particular, it is of vital importance to know what radionuclides are associated with solid ...

2002-04-02

16

Inventory of Tank Farm equipment stored or abandoned aboveground  

Energy Technology Data Exchange (ETDEWEB)

This document provides an inventory of Tank Farm equipment stored or abandoned aboveground and potentially subject to regulation. This inventory was conducted in part to ensure that Westinghouse Hanford Company (WHC) does not violate dangerous waste laws concerning storage of potentially contaminated equipment/debris that has been in contact with dangerous waste. The report identifies areas inventoried and provides photographs of equipment.

1994-10-12

17

Status and progress in sludge washing: A pivotal pretreatment method  

Energy Technology Data Exchange (ETDEWEB)

Separation of the bulk soluble chemical salts from the insoluble metal hydroxides and radionuclides is central to the strategy of disposing Hanford tank waste. Sludge washing and caustic leaching have been selected as the primary methods for processing the 230 million L (61,000,000 gal) of Hanford tank waste. These processes are very similar to those selected for processing waste at the West Valley Site in New York and the Savannah River Site in South Carolina. The purpose of sludge washing is to dissolve and remove the soluble salts in the waste. Leaching of the insoluble solids with caustic will be used to dissolve aluminum hydroxide and chromium hydroxide, and convert insoluble bismuth phosphate to soluble phosphate. The waste will be separated into a high-level solids fraction and a liquid fraction that can be disposed of as low-level waste after cesium removal. The washing and leaching operations ...

1995-01-01

18

Low-activity waste envelope definitions for the TWRS Privatization Phase I Request For Proposal  

Energy Technology Data Exchange (ETDEWEB)

Radioactive waste has been stored in large underground storage tanks at the Hanford Site since 1944. Approximately 212 million liters of waste containing approximately 240,000 metric tons of processed chemicals and 177 mega-curies of radionuclides are now stored in 177 tanks. These caustic wastes are in the form of liquids, slurries, saltcakes, and sludge. In 1991, the Tank Waste Remediation System (TWRS) Program was established to manage, retrieve, treat, immobilize, and dispose of these wastes in a safe, environmentally sound, and cost-effective manner. The Department of Energy (DOE) has believes that it is feasible to privatize portions of the TWRS Program. Under the privatization strategy embodied in the Request for Proposal (RFP), DOE will purchase services from a contractor-owned, contractor-operated facility under a fixed-price contract. Phase I of the TWRS privatization strategy is a ...

1996-11-01

19

The solubilities of significant organic compounds in HLW tank supernate solutions  

International Nuclear Information System (INIS)

Large quantities of organic chemicals used in reprocessing spent nuclear-fuels at the Hanford Site have accumulated in underground high-level radioactive waste tanks. The organic content of these tanks must he known so that the potential for hazardous reactions between organic components and sodium nitrate/nitrite salts in the waste can he evaluated. The solubilities of organic compounds described in this report will help determine if they are present in the solid phases (salt cake and sludges) as well as the liquid phase (interstitial liquor/supernate) in the tanks. The solubilities of five significant sodium salts of carboxylic acids and aminocarboxylic acids [sodium oxalate, formate, citrate, nitrilotriacetate (NTA) and ethylendiaminetetraacetate (EDTA)] were measured in a simulated supernate solution at 25 degrees C, 30 degrees C, 40 degrees C, and 50 degrees C.

1994-08-21

20

Melter system technology testing for Hanford Site low-level tankwaste vitrification  

Energy Technology Data Exchange (ETDEWEB)

Following revisions to the Tri-Party Agreement for Hanford Site cleanup, which specified vitrification for Complete melter feasibility and system operability immobilization of the low-level waste (LLW) tests, select reference melter(s), and establish reference derived from retrieval and pretreatment of the radioactive LLW glass formulation that meets complete systems defense wastes stored in 177 underground tanks, commercial requirements (June 1996). Available melter technologies were tested during 1994 to 1995 as part of a multiphase program to select reference Submit conceptual design and initiate definitive design technologies for the new LLW vitrification mission.

1996-05-03

21

Enhanced sludge washing evaluation plan  

Energy Technology Data Exchange (ETDEWEB)

The Tank Waste Remediation System (TWRS) Program mission is to store, treat, and immobilize highly radioactive Hanford Site waste (current and future tank waste and the strontium/cesium capsules) in an environmentally sound, safe, and cost-effective manner. The scope of the TWRS Waste Pretreatment Program is to treat tank waste and separate that waste into HLW and LLW fractions and provide additional treatment as required to feed LLW and HLW immobilization facilities. Enhanced sludge washing was chosen as the baseline process for separating Hanford tank waste sludge. Section 1.0 briefly discusses the purpose of the evaluation plan and provides the background that led to the choice of enhanced sludge washing as the baseline process. Section 2.0 provides a brief summary of the evaluation plan details. Section 3.0 discusses, in some detail, the technical work ...

1994-09-01

22

Control of the reduction/oxidation potential of Hanford Waste Vitrification Plant feeds  

International Nuclear Information System (INIS)

A schematic diagram shows the various processing steps to be performed during feed preparation in the Hanford Waste Vitrification Plant (HWVP). The pretreated NCAW is transferred to the slurry receipt adjustment tank (SRAT) in the HWVP for concentration. Water removed during boildown is collected in the slurry mix evaporator condensate tank (SMECT). After waste treatment the water is returned to the storage tanks for eventual disposal. The pretreated Neutralized Current Acid Waste (NCAW) is concentrated in the SRAT to approximately 125 g waste oxides/ liter. Formic acid is then added at a controlled rate to improve rheological properties and achieve a required reduction/oxidation state. Reflux boiling is initiated and continued for several hours. The concentrated slurry is cooled and pumped to the slurry mix evaporator (SME). In the SME, glass frit is added, and the slurry is further concentrated to ...

1988-09-11

23

Advanced organic analysis and analytical methods development: FY 1995 progress report. Waste Tank Organic Safety Program  

Energy Technology Data Exchange (ETDEWEB)

This report describes the work performed during FY 1995 by Pacific Northwest Laboratory in developing and optimizing analysis techniques for identifying organics present in Hanford waste tanks. The main focus was to provide a means for rapidly obtaining the most useful information concerning the organics present in tank waste, with minimal sample handling and with minimal waste generation. One major focus has been to optimize analytical methods for organic speciation. Select methods, such as atmospheric pressure chemical ionization mass spectrometry and matrix-assisted laser desorption/ionization mass spectrometry, were developed to increase the speciation capabilities, while minimizing sample handling. A capillary electrophoresis method was developed to improve separation capabilities while minimizing additional waste generation. In addition, considerable emphasis has been placed on developing a rapid screening tool, based ...

1995-09-01

24

C-106 tank process ventilation test  

Energy Technology Data Exchange (ETDEWEB)

Project W-320 Acceptance Test Report for tank 241-C-106, 296-C-006 Ventilation System Acceptance Test Procedure (ATP) HNF-SD-W320-012, C-106 Tank Process Ventilation Test, was an in depth test of the 296-C-006 ventilation system and ventilation support systems required to perform the sluicing of tank C-106. Systems involved included electrical, instrumentation, chiller and HVAC. Tests began at component level, moved to loop level, up to system level and finally to an integrated systems level test. One criteria was to perform the test with the least amount of risk from a radioactive contamination potential stand point. To accomplish this a temporary configuration was designed that would simulate operation of the systems, without being connected directly to the waste tank air space. This was done by blanking off ducting to ...

1998-07-20

25

Summary of Initial Testing of SuperLig 644 at the TFL Ion Exchange Facility  

Energy Technology Data Exchange (ETDEWEB)

Research at the Savannah River Technology Center aided development of a technical design basis for a Waste Treatment Plant (WTP) to pre-treat and vitrify Hanford tank waste as part of the River Protection Project (RPP). The research addresses safety concerns, process optimization, and waste form compliance. This program will provide technical data to ensure that the process functions as it was designed and minimizes costs.

2001-04-17

26

Melter Disposal Strategic Planning Document  

Energy Technology Data Exchange (ETDEWEB)

This document describes the proposed strategy for disposal of spent and failed melters from the tank waste treatment plant to be built by the Office of River Protection at the Hanford site in Washington. It describes program management activities, disposal and transportation systems, leachate management, permitting, and safety authorization basis approvals needed to execute the strategy.

2000-09-25

27

An approach to software quality assurance for robotic inspection systems  

International Nuclear Information System (INIS)

Software quality assurance (SQA) for robotic systems used in nuclear waste applications is vital to ensure that the systems operate safely and reliably and pose a minimum risk to humans and the environment. This paper describes the SQA approach for the control and data acquisition system for a robotic system being developed for remote surveillance and inspection of underground storage tanks (UST) at the Hanford Site.

1993-11-14

28

Potential for erosion corrosion of SRS high level waste tanks  

Energy Technology Data Exchange (ETDEWEB)

SRS high-level radioactive waste tanks will not experience erosion corrosion to any significant degree during slurry pump operations. Erosion corrosion in carbon steel structures at reported pump discharge velocities is dominated by electrochemical (corrosion) processes. Interruption of those processes, as by the addition of corrosion inhibitors, sharply reduces the rate of metal loss from erosion corrosion. The well-inhibited SRS waste tanks have a near-zero general corrosion rate, and therefore will be essentially immune to erosion corrosion. The experimental data on carbon steel erosion corrosion most relevant to SRS operations was obtained at the Hanford Site on simulated Purex waste. A metal loss rate of 2.4 mils per year was measured at a temperature of 102 C and a slurry velocity comparable to calculated SRS slurry velocities on ground specimens of the same carbon steel used in SRS waste tanks. ...

1994-01-01

29

Actinide, strontium, and cesium removal from Hanford radioactive tank sludge  

International Nuclear Information System (INIS)

A pretreatment flowsheet was tested for separating key radionuclide components from the sludge stored in one of the high level waste tanks (B-110) at the Hanford Site; this sludge resulted primarily from the bismuth phosphate process, which was one of the three major plutonium separation processes used at Handford. This test involved (1) washing with water, (2) caustic leaching, (3) acid dissolution, (4) separation of transuranic elements (TRUs) by extraction with octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide(CMPO), (5) separation of Sr by extraction with di-t-butylcyclohexano-18-crown-6, (6) separation of Cs from the acid-dissolved sludge solution by treatment with ammonium molybdophosphate (AMP), and (7) separation of Cs from the sludge wash and caustic leach solutions by ion exchange using a phenol-formaldehyde resin (CS-100). The results of the radionuclide separation steps indicated that the proposed flowsheet is a viable ...

30

Helium Tank for Cryoplant  

CERN Document Server

Helium Tank point5

2001-01-01

31

Advanced conceptual design report: T Plant secondary containment and leak detection upgrades. Project W-259  

Energy Technology Data Exchange (ETDEWEB)

The T Plant facilities in the 200-West Area of the Hanford site were constructed in the early 1940s to produce nuclear materials in support of national defense activities. T Plant includes the 271-T facility, the 221-T facility, and several support facilities (eg, 2706-T), utilities, and tanks/piping systems. T Plant has been recommended as the primary interim decontamination facility for the Hanford site. Project W-259 will provide capital upgrades to the T Plant facilities to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. This document provides an advanced conceptual design concept that complies with functional requirements for the T Plant Secondary Containment and Leak Detection upgrades.

1995-05-12

32

Corrosion studies of carbon steel under impinging jets of simulated slurries of neutralized current acid waste (NCAW) and neutralized cladding removal waste (NCRW)  

Energy Technology Data Exchange (ETDEWEB)

Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank`s structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries simulated the actual NCRW and NCAW both chemically and ...

1992-01-01

33

Multiple Ion Exchange Column Tests for Technetium Removal from Hanford Tank Waste Supernate  

Science.gov (United States)

Five cycles of loading, elution, and regeneration were performed to remove technetium from a Hanford waste sample retrieved from Tank 241-AW-101 using SuperLig 639 resin. The waste sample was diluted to 4.95 M Na plus and then was processed to remove 137Cs through dual ion exchange columns each containing 15 mL of SuperLig 644. To remove 99Tc, the cesium decontaminated solution was processed downwards through two ion exchange columns, each containing 12 mL of SuperLig 639 resin. The columns, designated as lead and lag, each had an inside diameter of 1.45 cm and a height of 30 cm. The columns were loaded in series, but were eluted and then regenerated separately. The average technetium loading for the cycles was 250 BV at 10 percent breakthrough. There was no significant difference in the loading performances among the five cycles. The percent removal of 99Tc was greater than 99.94 percent and the average decontamination factor (DF) was ...

2004-02-27

34

Ion exchange at TNX using the SKID unit  

Energy Technology Data Exchange (ETDEWEB)

An ion exchange unit has been manufactured for WSRC by British Nuclear Fuels, Ltd. This unit consists of three columns, ancillary valving, pumps, lines, and computer controls. It has been delivered to TNX for use in testing a cesium-specific ion exchange resin, developed at WSRC as a potential second generation process for the decontamination of Defense Waste Processing Facility (DWPF) supernate. This resin also has Department of Energy applications at both Oak Ridge and Hanford. Oak Ridge is interested in decontaminating the Melton Valley storage tank supernate, while Hanford is interested in decontaminating the 101-AW and 101-SY supernate streams. Another potential developmental interest is the Savannah River Site (SRS) DWPF recycle stream. The three primary waste streams of interest are the Oak Ridge, Hanford, and SRS, SWPF supernate streams. For these three waste streams, the cesium decontamination ...

1993-10-21

35

Development program for magnetically assisted chemical separation: Evaluation of cesium removal from Hanford tank supernatant  

International Nuclear Information System (INIS)

Magnetic particles (MAG*SEP"S"M) coated with various absorbents were evaluated for the separation and recovery of low concentrations of cesium from nuclear waste solutions. The MAG*SEP"S"M particles were coated with (1) clinoptilolite, (2) transylvanian volcanic tuff, (3) resorcinol formaldehyde, and (4) crystalline silico-titanate, and then were contacted with a Hanford supernatant simulant. Particles coated with the crystalline silico-titanate were identified by Bradtec as having the highest capacity for cesium removal under the conditions tested (variation of pH, ionic strength, cesium concentration, and absorbent/solution ratio). The MAG*SEP"S"M particles coated with resorcinol formaldehyde had high distribution ratios values and could also be used to remove cesium from Hanford supernant simulant. Gamma irradiation studies were performed on the MAG*SEP"S"M particles with a gamma dose equivalent to 100 cycles of use. This irradiation ...

1994-05-09

36

Performance expectation plan  

Energy Technology Data Exchange (ETDEWEB)

This document outlines the significant accomplishments of fiscal year 1998 for the Tank Waste Remediation System (TWRS) Project Hanford Management Contract (PHMC) team. Opportunities for improvement to better meet some performance expectations have been identified. The PHMC has performed at an excellent level in administration of leadership, planning, and technical direction. The contractor has met and made notable improvement of attaining customer satisfaction in mission execution. This document includes the team`s recommendation that the PHMC TWRS Performance Expectation Plan evaluation rating for fiscal year 1998 be an Excellent.

1998-09-04

37

Corrosion studies of carbon steel under impinging jets of simulated slurries of neutralized current acid waste (NCAW) and neutralized cladding removal waste (NCRW)  

Energy Technology Data Exchange (ETDEWEB)

Plans for the disposal of radioactive liquid and solid wastes presently stored in double-shell tanks at the Hanford Site call for retrieval and processing of the waste to create forms suitable for permanent disposal. Waste will be retrieved from a tank using a submerged slurry pump in conjunction with one or more rotating slurry jet mixer pumps. Pacific Northwest Laboratory (PNL) has conducted tests using simulated waste slurries to assess the effects of a impinging slurry jet on the corrosion rate of the tank wall and floor, an action that could potentially compromise the tank's structural integrity. Corrosion processes were investigated on a laboratory scale with a simulated neutralized cladding removal waste (NCRW) slurry and in a subsequent test with simulated neutralized current acid waste (NCAW) slurry. The test slurries simulated the actual NCRW and NCAW both ...

1992-01-01

38

Hanford Speakers Bureau - Hanford Site  

Science.gov (United States)

to Cool Spots Hanford Fun Facts Classroom Projects Famous People of Hanford Counterintelligence Home Employee Responsibilities CI Information CI Resources Points of Contact...

2011-10-02

39

Performance objectives for the Hanford immobilized low-activity waste (ILAW) performance assessment  

Energy Technology Data Exchange (ETDEWEB)

Before low-level waste may be disposed of, a performance assessment must be written and then approved by the DOE (DOE 1988a DOE 1999a). The performance assessment is to determine whether ''reasonable assurance'' exists that the performance objectives of the disposal facility will be met. The DOE requirements for waste disposal (DOE 1988a DOE 1999a) require the protection of public health and safety; and the protection of the environment. Although quantitative limits are sometimes stated (for example, the all-pathways exposure limit is 25 mrem/year), usually the requirements are stated in a general nature. Quantitative limits were established by: investigating all potentially applicable regulations as well as interpretations of the review panels which DOE has established to review performance assessments, interacting with program management to establish the additional requirements of the program, and interacting with the public (i.e., the ...

1999-09-09

40

Synthesis, structural characterization, and performance evaluation of resorcinol-formaldehyde (R-F) ion-exchange resin  

International Nuclear Information System (INIS)

The 177 underground storage tanks at the DOE's Hanford Site contain an estimated 180 million tons of high-level radioactive wastes. It is desirable to remove and concentrate the highly radioactive fraction of the tank wastes for vitrification. Resorcinol-formaldehyde (R-F) resin, an organic ion-exchange resin with high selectivity and capacity for the cesium ion, which is a candidate ion-exchange material for use in remediation of tank wastes. The report includes information on the structure/function analysis of R-F resin and the synthetic factors that affect performance of the resin. CS-100, a commercially available phenol-formaldehyde (P-F) resin, and currently the baseline ion-exchanger for removal of cesium ion at Hanford, is compared with the R-F resin. The primary structural unit of the R-F resin was determined to consist of a 1,2,3,4-tetrasubstituted resorcinol ring unit ...

2004-09-10

41

Rotary Mode Core Sample System availability improvement  

Energy Technology Data Exchange (ETDEWEB)

The Rotary Mode Core Sample System (RMCSS) is used to obtain stratified samples of the waste deposits in single-shell and double-shell waste tanks at the Hanford Site. The samples are used to characterize the waste in support of ongoing and future waste remediation efforts. Four sampling trucks have been developed to obtain these samples. Truck I was the first in operation and is currently being used to obtain samples where the push mode is appropriate (i.e., no rotation of drill). Truck 2 is similar to truck 1, except for added safety features, and is in operation to obtain samples using either a push mode or rotary drill mode. Trucks 3 and 4 are now being fabricated to be essentially identical to truck 2.

1995-02-28

42

Groundwater quality assessment plan for single-shell tank waste management Area U at the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

Waste Management Area U (WMA U) includes the U Tank Farm, is currently regulated under RCRA interim-status regulations, and is scheduled for closure probably post-2030. Groundwater monitoring has been under an evaluation program that compared general contaminant indicator parameters from downgradient wells to background values established from upgradient wells. One of the indicator parameters, specific conductance, exceeded its background value in one downgradient well triggering a change from detection monitoring to a groundwater quality assessment program. The objective of the first phase of this assessment program is to determine whether the increased concentrations of nitrate and chromium in groundwater are from WMA U or from an upgradient source. Based on the results of the first determination, if WMA U is not the source of contamination, then the site will revert to detection monitoring. If WMA U is the source, then a second part of the groundwater quality ...

2000-03-21

43

Evaluation of scaling correlations for mobilization of double-shell tank waste  

Energy Technology Data Exchange (ETDEWEB)

In this report, we have examined some of the fundamental mechanisms expected to be at work during mobilization of the waste within the double-shell tanks at Hanford. The motivation stems from the idea that in order to properly apply correlations derived from scaled tests, one would have to ensure that appropriate scaling laws are utilized. Further, in the process of delineating the controlling mechanisms during mobilization, the currently used computational codes are being validated and strengthened based on these findings. Experiments were performed at 1/50-scale, different from what had been performed in the previous fiscal years (i.e., 1/12- and 1/25-scale). It was anticipated that if the current empirical correlations are to work, they should be scale invariant. The current results showed that linear scaling between the 1/25-scale and 1/50-scale correlations do not work well. Several mechanisms were examined in the scaled tests which might ...

1997-09-01

44

Weather - Hanford Site  

Science.gov (United States)

to Cool Spots Hanford Fun Facts Classroom Projects Famous People of Hanford Counterintelligence Home Employee Responsibilities CI Information CI Resources Points of Contact...

2011-10-01

45

UNSAT-H Version 3.0: Unsaturated Soil Water and Heat Flow Model Theory, User Manual, and Examples  

Energy Technology Data Exchange (ETDEWEB)

The UNSAT-H model was developed at Pacific Northwest National Laboratory (PNNL) to assess the water dynamics of arid sites and, in particular, estimate recharge fluxes for scenarios pertinent to waste disposal facilities. During the last 4 years, the UNSAT-H model received support from the Immobilized Waste Program (IWP) of the Hanford Site's River Protection Project. This program is designing and assessing the performance of on-site disposal facilities to receive radioactive wastes that are currently stored in single- and double-shell tanks at the Hanford Site (LMHC 1999). The IWP is interested in estimates of recharge rates for current conditions and long-term scenarios involving the vadose zone disposal of tank wastes. Simulation modeling with UNSAT-H is one of the methods being used to provide those estimates (e.g., Rockhold et al. 1995; Fayer et al. 1999). To achieve the above goals for ...

2000-06-12

46

Quarterly progress report for the Chemical and Energy Research Section of the Chemical Technology Division: October-December 1997  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the major activities conducted in the Chemical and Energy Research Section of the Chemical Technology Division at Oak Ridge National Laboratory (ORNL) during the period October--December 1997. The section conducts basic and applied research and development in chemical engineering, applied chemistry, and bioprocessing, with an emphasis on energy-driven technologies and advanced chemical separations for nuclear and waste applications. The report describes the various tasks performed within six major areas of research: Hot Cell Operations, Process Chemistry and Thermodynamics, Separations and Materials Synthesis, Fluid Structure and Properties, Biotechnology Research, and Molecular Studies. The name of a technical contact is included with each task described, and readers are encouraged to contact these individuals if they need additional information. Activities conducted within the area of Hot Cell Operations included efforts to optimize the processing conditions ...

1999-02-01

47

Defense Waste and Environmental Restoration Program Plan: Defense Waste Management Division  

Energy Technology Data Exchange (ETDEWEB)

The DEFENSE WASTE MANAGEMENT PROGRAM has been chartered by the Department of Energy (DOE) to receive, reduce, store, and maintain all radioactive defense waste generated by Hanford and received from offsite DOE contractors in a safe condition and in accordance with DOE and Westinghouse Hanford Company (WHC) standards. These activities are accomplished through the use of TRU retrievable storage sites, solid waste burial grounds, liquid waste storage tanks, capsule storage pools, and other low-level waste disposal methods. Continuous and/or periodic surveillance is maintained. Through the use of improved packaging methods, evaporator-crystallization and capsule production waste has been and continues to be put in a safe and economic storage condition pending future reprocessing or final disposition. For this Program Plan, the scope of Defense Waste Management programmatic activities has been organized into three general ...

1988-09-01

48

Evaluation of methods to measure surface level in waste storage tanks: Second test sequence  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results of a program conducted at the Pacific Northwest Laboratory (PNL) and Westinghouse Hanford Company (WHC) to identify alternative methods to measure the surface level in the waste tanks. This program examined commercially available devices for measuring the distance to a target. This is a continuation of a program started in FY93. In the first test sequence, tests were performed.on five devices to determine their applicability to measure the surface level in the waste tanks. The devices were the Enraf-Nonius{trademark} Model 872 Radar Gauge, the Enraf-Nonius{trademark} Model 854 Advanced Technology Gauge (ATG), the Stanley Tool Laser Measuring Device, the Robertshaw Inven-Tel{reg_sign} Precision Level Gauge, and the Micro Switch Model 942 Acoustic Sensor. In addition, discussions were held with several manufacturer representatives regarding other potential devices. The results of these tests ...

1993-09-01

49

SIMV: An Application of Mathematical Modeling in Ventilator Management  

UK PubMed Central (United Kingdom)

SIMV (simulation and modeling of ventilation) is a quantitative system for the mathematical modeling and simulation of pulmonary...Full Text Available

1989-11-08

50

Low-Level waste phase 1 melter testing off gas and mass balance evaluation  

Energy Technology Data Exchange (ETDEWEB)

Commercially available melter technologies were tested during 1994-95 as part of a multiphase program to test candidate technologies for vitrification of the low-level waste (LLW) stream to be derived from retrieval and pretreatment of Hanford Site tank wastes. Seven vendors were selected for Phase 1 testing to demonstrate vitrification of a high sodium content liquid LLW simulant. The tested melter technologies included four Joule-heated melters, a carbon electrode melter, a combustion melter, and a plasma melter. Various dry and slurry melter feed preparation processes were also tested. Various feed material samples, product glass samples, and process offgas streams were characterized to provide data for evaluation of process decontamination factors and material mass balances for each vitrification technology. This report describes the melter mass balance evaluations and results for six of the Phase 1 LLW melter vendor demonstration tests.

1996-06-28

51

EFFECTS OF QUARTZ PARTICLE SIZE AND SUCROSE ADDITION ON MELTING BEHAVIOR OF A MELTER FEED FOR HIGH-LEVEL GLASS  

Energy Technology Data Exchange (ETDEWEB)

The behavior of melter feed (a mixture of nuclear waste and glass-forming additives) during waste-glass processing has a significant impact on the rate of the vitrification process. We studied the effects of silica particle size and sucrose addition on the volumetric expansion (foaming) of a high-alumina feed and the rate of dissolution of silica particles in feed samples heated at 5 C/min up to 1200 C. The initial size of quartz particles in feed ranged from 5 to 195 {micro}m. The fraction of the sucrose added ranged from 0 to 0.20 g per g glass. Extensive foaming occurred only in feeds with 5-{micro}m quartz particles; particles {ge}150 {micro}m formed clusters. Particles of 5 {micro}m completely dissolved by 900 C whereas particles {ge}150 {micro}m did not fully dissolve even when the temperature reached 1200 C. Sucrose addition had virtually zero impact on both foaming and the dissolution of silica particles. Over 100 sites in the United States are currently tasked with the storage ...

2010-07-28

52

Building ventilation, state of the art, prospective; Ventilation des batiments etat des lieux, prospective  

Energy Technology Data Exchange (ETDEWEB)

This conference is composed of 21 communications and 21 posters in the domain of building ventilation and indoor air quality; the main themes are: indoor air quality assessment and optimization; performance enhancement and optimization of ventilation systems and equipment; ventilation systems for renovated and rehabilitated buildings; French and European regulations, standardizations and certifications; experimental and numerical simulation studies concerning ventilation systems, air flow, temperature distribution, air quality, thermal comfort and ventilation-induced acoustic levels

1995-10-01

53

Gas fired heaters and ventilation system improve indoor air quality and thermal comfort  

Energy Technology Data Exchange (ETDEWEB)

Rotex Inc. has designed and manufactured industrial sifting equipment since 1844. This site (an existing industrial facility) encompasses approximately 140,000 ft[sup 2] (13,006 m[sup 2]) of offices, R D shops, assembly and storage areas, as well as a large welding shop that was the main focus of this project. This facility consists of three separate buildings that are all connected and open to one another. The original building dates from 1908. The newest addition (32,400 ft[sup 2]; 3,010 m[sup 2]) was added in 1977, and is referred to as the 77 Building. This building was initially equipped with oil fired heating equipment due to the moratorium on new gas sales that was in effect at that time. This project was driven by the client's need to remove underground oil storage tanks to comply with environmental standards. This article describes the 77 Building conversion from oil to an environmentally cleaner fuel, natural gas. Existing heaters were removed ...

1994-03-01

54

Nomographs estite floating-roof tank evaporation  

Energy Technology Data Exchange (ETDEWEB)

Nomographs are presented that estimate the evaporation loss from external floating-roof tanks using tank diameter, type of seal, product vapor pressure, and wind velocity.

1986-01-27

55

Maintaining Tank and Infantry Integration Training  

Science.gov (United States)

Page 1. Maintaining Tank and Infantry Integration Training ... 4. TITLE AND SUBTITLE Maintaining Tank and Infantry Integration Training 5a. ...

2005-01-11

56

Survival in Patients Receiving Prolonged Ventilation: Factors that Influence Outcome  

UK PubMed Central (United Kingdom)

Background:Prolonged mechanical ventilation is increasingly common. It is expensive and associated with significant morbidity and mortality. Our objective is to comprehensively characterize...Full Text Available

57

Combustible Metallic Igniter Casing for Tank Guns  

Science.gov (United States)

... TANK GUNS, GUNS, CHAMBERS, IGNITERS, INTERIOR BALLISTICS, INTERNAL PRESSURE, COMBUSTIBLE CARTRIDGE CASES, METALS. ...

1991-11-01

58

Public agency partnership: Hanford`s history artifacts as a communications tool  

Energy Technology Data Exchange (ETDEWEB)

The Hanford Site in eastern Washington state currently is engaged in the largest waste cleanup in world history. In order to make informed decisions about remediation options, the public throughout the Pacific Northwest and the nation needs to understand the wastes that are present, their sources of generation, their composition, and their behavior in the environment. The fact that Hanford operations` were conducted in secret for over four decades presents a unique public information challenge to those who currently are responsible for communicating with the public.

1994-02-01

59

Hanford Internal Dosimetry Program Manual, PNL-MA-552  

Energy Technology Data Exchange (ETDEWEB)

This manual is a guide to the services provided by the Hanford Internal Dosimetry Program (IDP), which is operated by the Pacific Northwest National Laboratory.( ) for the U.S. Department of Energy Richland Operations Office, Office of River Protection and their Hanford Site contractors. The manual describes the roles of and relationships between the IDP and the radiation protection programs of the Hanford Site contractors. Recommendations and guidance are also provided for consideration in implementing bioassay monitoring and internal dosimetry elements of radiation protection programs.

2009-09-24

60

Hanford Waste Vitrification Plant Quality Assurance Program description for high-level waste form development and qualification  

International Nuclear Information System (INIS)

The Hanford Waste Vitrification Plant Project has been established to convert the high-level radioactive waste associated with nuclear defense production at the Hanford Site into a waste form suitable for disposal in a deep geologic repository. The Hanford Waste Vitrification Plant will mix processed radioactive waste with borosilicate material, then heat the mixture to its melting point (vitrification) to forin a glass-like substance that traps the radionuclides in the glass matrix upon cooling. The Hanford Waste Vitrification Plant Quality Assurance Program has been established to support the mission of the Hanford Waste Vitrification Plant. This Quality Assurance Program Description has been written to document the Hanford Waste Vitrification Plant Quality Assurance Program.

1993-05-06

61

Bechtel Hanford Inc. Network Security Plan for the EnvironmentalRestoration Contract  

Science.gov (United States)

'As part of the Computer Protection Plan, this Network Security Plan identifies the specific security measures used to protect Bechtel Hanford, Inc.'s (BHI's) enterprise network. The network consists of the communication infrastructure and information systems used by BHI to perform work related to the Environmental Restoration Contract (ERC) at the Hanford Site. It provides electronic communication between the ERC-leased facilities in Richland, Washington, and facilities located on the Hanford Site. Network gateways to other site and offsite networks provide electronic communication with the remainder of the Hanford community.'

1999-06-30

62

Regulation about the technical environment of buildings: boiler-rooms / ventilation systems; RETA: chaufferies / ventilation  

Energy Technology Data Exchange (ETDEWEB)

This CD-Rom edited by the French scientific and technical committee of the space heating, ventilation and air-conditioning industry (CoSTIC) presents a series of technical files about ventilation and space heating systems with several references to the current regulatory texts. Modifications of the original legislative texts have been integrated to the original texts for a more comfortable reading. Search is performed using diagrams and key-words. (J.S.)

2000-06-01

63

Power fluidics for ventilation control  

International Nuclear Information System (INIS)

... amplification exhaust systems fluidic control devices gloveboxes pressure

1984-11-28

68

An investigation of passive ventilation cooling and control strategies for an educational building  

Energy Technology Data Exchange (ETDEWEB)

Many non-domestic buildings, built recently in the UK, use natural means to provide ventilation for indoor air quality and thermal comfort. This paper presents monitoring results obtained from such a purpose built naturally ventilated educational building. Its performance during the summer is discussed based on monitored results. Using thermal and ventilation modelling, the paper also discusses the optimisation of the building's summer performance. Recommendations on the selection of appropriate ventilation strategies in relation to the prevailing external conditions are derived and the appropriateness of the control methods is discussed. (author)

2001-02-01

69

Criticality safety review of FFTF interim decay storage tank  

Science.gov (United States)

The Interim Decay Storage tank (IDS) will be located in a concrete cell in the FFTF reactor building. The tank will have capacity to store 112 driver fuel assemblies and 10 test assemblies in sodium. A criticality safety analysis for the design of the IDS tank was performed. From the analysis, it is concluded that under normal operating conditions and minor abnormal conditions that might shift the fuel, the IDS tank will remain adequately subcritical. (auth)

1975-10-01

70

Natural and hybrid ventilation in schoolhouses. Requirements on air quality and thermal conditions; Naturlig og hybrid ventilasjon i skolebygninger  

Energy Technology Data Exchange (ETDEWEB)

The indoor climate of school buildings have been much debated recently. Many problems connected with air quality and thermal comfort are caused by bad maintenance, fitted carpets and no sunshades. Mechanical ventilation in schools has gained a bad reputation and many municipalities are seeking other solutions when building new schools. Natural ventilation according to the ''Swedish model'' does not use air filters or heat recovery from the outgoing air and achieve low energy consumption by reducing the airflow substantially in cold weather. Most of the naturally ventilated schools have supply air culverts of concrete below ground outside the building and in the basement. This is also true of schools using hybrid ventilation, where natural and mechanical ventilation is combined. The naturally ventilated schools often use manual ...

2000-07-01

71

Free air flows for the removal of pollutants from car parks. Air-conditioning systems without sheet-metal ducts as an alternative to transverse ventilation with sheet-metal ducts. Pt. 2. Freie Luftstroemungen entsorgen Parkraeume. RLT-Anlagen ohne Blechkanaele als Alternative zur Querlueftung mit Blechkanaelen. T. 2  

Energy Technology Data Exchange (ETDEWEB)

In parking areas of large extent, the removal of engine exhaust gases, especially of their CO gas components with ventilation plant is mainly done by transverse ventilation over short paths. By their presence, the ventilation ducts required for this purpose often reduce the value of the parking space by restrictions with a consequent reduction of their acceptance by the users. Longitudinal ventilation without ducts can be a remedy in such cases. Depending on the required room air quality in the zones of highest loading, the volume flows with longitudinal removal are no greater than with conventional transverse ventilation. This article is concerned with the different methods of operation of the two systems. (orig./BWI)

1994-04-01

72

Decontamination of spent fuel dissolution tank  

International Nuclear Information System (INIS)

The decontamination of the dissolution tank from spent fuel reprocessing out-ling device is studied, by using FL-AP decontamination agent. The decontamination factor per step is 2.2, 2.4, respectively for #alpha#, #beta# activities. After dissecting the tank, residual contamination in inner surface of the tank was found to be non-uniform. The exact original contamination value of the tank surface could be approximated by calculating the total amounts of radionuclide distributed on the hanging specimens, the dissecting specimen, and radioactive level in waste decontamination agent. Therefore, it can be concluded that the hanging specimens method is feasible for measuring the decontamination factor of spent fuel dissolution tank. (authors)

2006-01-01

73

Hanford Site environmental report for calendar year 1989  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the environmental status of the Hanford Site in 1989. It includes descriptions of the Site and its mission, the status of compliance with environmental regulations, planning and activities to accomplish compliance, environmental protection and restoration activities, and environmental monitoring. 97 refs., 67 figs., 14 tabs.

1990-05-01

75

Oral histories at the Hanford Nuclear Reservation  

Energy Technology Data Exchange (ETDEWEB)

The founding of the Hanford Engineering Works to produce plutonium is described. The 45-year defense mission has now been replaced with a peaceful mission, that of being the first site for massive cleanup of the 45-year nuclear waste. In order to establish a remedial investigation and feasibility plan, a process of discovery named the Technical Baseline Report must be performed; the task of this process is to discover all that is known about a proposed cleanup site (what the waste was, where did it go). When none of the documentation can answer the question, oral history is utilized. Some of the problems associated with the conduct of oral history interviews are described, particularly Hanford`s legacy of secrecy.

1992-03-01

77

Interim remedial measures proposed plan for the 200-ZP-1 Operable Unit, Hanford Site, Washington  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this interim remedial measures (IRM) proposed plan is to present and solicit public comments on the IRM planned for the 200-ZP-1 Operable Unit at the Hanford Site in Washington state. The 200-ZP-1 is one of two operable units that envelop the groundwater beneath the 200 West Area of the Hanford Site.

1993-12-01

78

Ventilated Improved Pit Latrines: Recent Developments in Zimbabwe.  

Science.gov (United States)

Contents: Ventilated improved pit latrines; (General description, odor control, insect control); Zimbabwean VIP latrine designs; (Latrine entrance, ferrocement spirals, rural spirals, training and education, design transfer).

1982-01-01

79

Carbon Monoxide Protects against Ventilator-induced Lung Injury via PPAR-? and Inhibition of Egr-1  

UK PubMed Central (United Kingdom)

Rationale: Ventilator-induced lung injury (VILI) leads to an unacceptably high mortality. In this regard, the antiinflammatory properties of inhaled carbon monoxide (CO) may provide...Full Text Available

2008-06-01

80

The need for action in the housing ventilation area is essential; Bei der Wohnungslueftung besteht grosser Handlungsbedarf  

Energy Technology Data Exchange (ETDEWEB)

This short article discusses the results of a market survey on ventilation systems for residential buildings and the role played by ventilation systems in our daily lives. Problems incurred as a result of insufficient ventilation conditions such as the formation of mould in dwellings whose windows have been replaced with better seals are discussed, for example. The negative image of air-conditioning and its causes are examined. The need for action in this area is stressed. Further findings of the study are presented, including a detailed review of current equipment and scenarios on how these systems can develop in the future. The extension of the study to cover the situation in further European countries is mentioned.

2003-07-01

81

Summary of Uranium City, Saskatchewan remedial measures for radiation reduction with special attention to vent fan theory  

International Nuclear Information System (INIS)

Various remedial measures have been tried to lower radon levels in buildings in Uranium City. The methods used are source material removal, passive ventilation of crawl spaces, sub-floor ventilation, complete epoxy coating of the entire basement, sealants for floor-wall joints and cracks in basements, electrostatic precipitators, mechanical ventilation, and sealing and grouting concrete block plenums in basement walls. The type and condition of structures encountered in Uranium City as well as the relative isolation of the town indicate that mechanical ventilation is the most long-term cost-effective method.

1980-03-12

82

Multicriteria analysis of ventilation in summer period  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a multicriteria analysis of ventilation during summertime in Europe. Multicriteria analysis theories are used to determine the most suitable ventilation strategy on a university building, that is to say to ensure the best possible indoor air quality, thermal comfort of the occupants and the lower energy consumption in case of accelerated diurnal or nocturnal ventilation and/or air conditioning. After defining the possible actions, the criteria of quality regarding thermal comfort, indoor air quality and energy consumption are defined. The possible actions are then assessed relative to each of these three criteria and ranked from the best to the worst ones using two different multicriteria analysis methods. (author)

2002-02-01

83

Ventilation of Ukrainian mines and its improvement  

Energy Technology Data Exchange (ETDEWEB)

Mining depth in coal basins of the Ukrainian SSR increases by 12 to 18 m/year and ventilation conditions become more complicated due to increasing methane content in coal seams and hazards of coal spontaneous combustion. Over 87% of Ukrainian coal mines is characterized by methane or carbon dioxide content. In some gassy mines gas emission is as high as 173 m/SUP/3/min. Length of ventilation tunnels in Ukrainian coal mines ranges from 2.1 to 15 km and the average length amounts to 7.3 km. In underground mines of the Ukrainian SSR 730 blowers are used: 61% axial flow blowers and 39% centrifugal blowers. The following blower types are most popular: the VOKD-1.5, VOKD-1.8, VODK-2.4, VTs-25, VTs-32 and VTsD-2.2. Ventilation network of Ukrainian mines consists of 1904 coal faces and 3125 development workings. Ventilation systems used in mines are shown in 2 schemes. Trends in ventilation ...

1982-04-01

84

CONVERTING WASTE  

Wastenet

condenser, gas refiner, oil (gas) storage tank and dual fuel engine

87

The feasibility of using a septic tank as a heat source for geothermal heat pumps  

Energy Technology Data Exchange (ETDEWEB)

A geothermal heat pump (GHP) system with three ground coils was installed in a residence in northern Idaho with a portion of the ground heat exchanger wrapped around the residential septic tank. The septic coil provided a significant portion of the heating for the residence over the heating season. There was no evidence of the septic tank freezing up or failing to properly function. Utilizing a septic tank as a heat source for GHP systems is feasible design option if the septic tank is used on a full-time basis. However, the tank should be surrounded on all sides by a large amount of soil and/or insulated from the ground surface to ensure that ground temperatures near the tank remain warm during the winter.

1999-11-01

88

Simulation on energy use for mechanical ventilation and air-conditioning (MVAC) systems in train compartments  

Energy Technology Data Exchange (ETDEWEB)

Unlike the conventional automotive, modem railway trains are designed with non-openable windows; and a mechanical ventilation and air-conditioning (MVAC) system is installed in each train compartment for better indoor air quality as well as to provide a thermally comfortable environment. The ventilation rate is no doubt a critical element in the design of a MVAC system, especially in Hong Kong where the daily passenger load is extremely heavy. Earlier studies illustrated that carbon dioxide can be controlled at 1000 ppm by increasing the ventilation rate to 25.2 m{sup 3} h{sup -1}; however, it will also lead to an increase in energy consumption. In this paper, the electrical energy consumption at various ventilation rates was studied, and the cost of maintaining a low carbon dioxide level was estimated These provide solid information for the local railway companies to improve the air quality inside the ...

2000-01-01

89

Effect of convective wall currents on the air quality of source ventilation. Einfluss konvektiver Wandstroemungen auf die Luftqualitaet bei Quellueftung  

Energy Technology Data Exchange (ETDEWEB)

With the combination of source ventilation and ceiling cooling for air-conditioning of working and recreation rooms, a ventilation system is available which fulfills the highest demands regarding thermal comfort. In order to utilize the advantages of this ventilation system with regard to air quality and thermal comfort to an optimum, the influence of the radiation exchange between cooling ceiling and walls on the flow in the room is investigated experimentally. Energy transfer from the walls to the cooled ceiling may result in an insufficient temperature of the walls compared to ambient air and in an upward flow on the wall surfaces (downward flow of) driven by gravity, which influences the flow pattern in the case of source ventilation. (orig.)

1993-07-01

90

Comparison Between Active and Passive Techniques for Radon Gas and Working Level measurements, El-Allouga Mine, Sinai, Egypt  

International Nuclear Information System (INIS)

Two different techniques were used for measuring Rn-gas concentrations and Working Level (WL) in U-exploration galleries at El-Allouga Mine, Sinai, Egypt. The active techniques used EDA(RDA-200) with calibrated Lucas cell and Tri-Met-372 instruments and passive techniques used four different types of SSNTD. Twenty eight (28) stations inside the studied tunnels were located covering the different environmental conditions. The measurements were carried out during summer time, in the ventilated sector (16 stations), the average tunnel air temperature was 24.4 #+-# 2.2 degree C and relative humidity 38%. In the non-ventilated sector (12 stations), the average tunnel air temperature was 22.2#+-#0.4 degree C and relative humidity 70%. The Rn-gas concentrations using EDA(RDA-200) and calibrated Lucas cell, in the ventilated sector averaged 11.966 p Ci/l, while in the non-ventilated stations averaged 786.21 p ...

2007-04-22

91

Vascular plants of the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

An updated listing of the vascular plants of the Hanford Site is provided, along with discussions of how humans may interact with local plants and have influenced the regional flora. Based on examinations of herbarium collections at the Westinghouse Hanford Company, Pacific Northwest Laboratory, Washington State University, and Brigham Young University, 590 vascular plant species have been identified on or near the Hanford Site. This is more than twice the number of species on previously published lists of Hanford Site vascular plants. A review of the plant species that are currently listed as endangered, threatened, sensitive, or otherwise of concern to the Washington State Natural Heritage Program and the Federal Fish and Wildlife Service is included. Color photographs of selected species are included to aid identification. Lists are provided of the Hanford Site plant species that ...

1992-07-01

92

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972. Hanford Environmental Dose Reconstruction Project  

Energy Technology Data Exchange (ETDEWEB)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate that these yearly summaries will be helpful ...

1992-07-01

93

Equipment for a central heating system with expansion tank, pressure control, water loss supply, de-aeration, recording and control; Apparaat t.b.v. C.V.-installatie met expansievat, drukregeling, waterverliessuppletie, ontluchting, registratie en controle  

Energy Technology Data Exchange (ETDEWEB)

The very low-pressure expansion tank of the title invention is connected to the water in the central heating installation via a connecting pipe with a pump and valves on one side, and on the other side the tank is connected via a connecting pipe with valve to the tap water mains, so that the supply of water can be regulated automatically. Within the expansion tank contact with the outside air is not possible because of an air/water separating floater. By means of recording and control (also remote) of the contents of the expansion tank, the installation pressure and the quantity of supplied water from the expansion tank and the tap water mains, failures and water damage are prevented. 4 figs.

1995-09-01

94

Hanford Federal Facility Agreement and Consent Order quarterly progress report for the period ending June 30, 1991  

Energy Technology Data Exchange (ETDEWEB)

This is the ninth quarterly report as required by the Hanford Federal Facility Agreement and Consent Order (Ecology et al. 1990), also known as the Tri-Party Agreement, established between the US Department of Energy (DOE), the US Environmental Protection Agency (EPA), and the Washington State Department of Ecology (Ecology). The Tri-Party Agreement sets the plan and schedule for achieving regulatory compliance and cleanup of waste sites at the Hanford Site. This report covers progress for the quarter that ended June 30, 1991. A total of 87 milestones have been completed to date. 39 refs., 1 fig.

1991-08-01

95

2001 evaluation of juvenile fall chinook stranding on the Hanford Reach of the Columbia River.; TOPICAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach of the Columbia River. The evaluation, in the fifth year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 2001 field season.

96

2000 evaluation of juvenile fall chinook stranding on the Hanford Reach of the Columbia River.; TOPICAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the fourth year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 2000 field season.

97

1999 evaluation of juvenile fall chinook stranding on the Hanford Reach of the Columbia River, annual report 1999.; ANNUAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the third year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fishes, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 1999 field season.

98

1998 evaluation of juvenile fall chinook salmon stranding on the Hanford Reach of the Columbia River.; TOPICAL  

International Nuclear Information System (INIS)

The Washington Department of Fish and Wildlife (WDFW) has been contracted through the Bonneville Power Administration (BPA) and the Grant County Public Utility District (GCPUD) to perform an evaluation of juvenile fall chinook salmon (Oncorhynchus tshawytscha) stranding on the Hanford Reach. The evaluation, in the second year of a multi-year study, has been developed to assess the impacts of water fluctuations from Priest Rapids Dam on rearing juvenile fall chinook salmon, other fish species, and benthic macroinvertebrates of the Hanford Reach. This document provides the results of the 1998 field season.

99

Waste Receiving and Processing Facility Module 2A: Advanced Conceptual Design Report. Volume 1  

Energy Technology Data Exchange (ETDEWEB)

This ACDR was performed following completed of the Conceptual Design Report in July 1992; the work encompassed August 1992 to January 1994. Mission of the WRAP Module 2A facility is to receive, process, package, certify, and ship for permanent burial at the Hanford site disposal facilities the Category 1 and 3 contact handled low-level radioactive mixed wastes that are currently in retrievable storage at Hanford and are forecast to be generated over the next 30 years by Hanford, and waste to be shipped to Hanford from about DOE sites. This volume provides an introduction to the ACDR process and the scope of the task along with a project summary of the facility, treatment technologies, cost, and schedule. Major areas of departure from the CDR are highlighted. Descriptions of the facility layout and operations are included.

1994-03-01

100

Environmental surveillance at Hanford for CY-1979  

Energy Technology Data Exchange (ETDEWEB)

Environmental data were collected for most environmental media including air, Columbia River water, external radiation, foodstuffs (milk, beef, eggs, poultry, and produce) and wildlife (deer, fish, and game birds), as well as soil and vegetation samples. In general, offsite levels of radionuclides attributable to Hanford operations during 1979 were indistinguishable from background levels. The data are summarized in the following highlights. Air quality measurements of NO/sub 2/ in the vicinity of the Hanford Site and releases of SO/sub 2/ onsite were well within the applicable federal and state standards. Particulate air concentrations exceed the standards primarily because of agricultural activities in the area. Discharges of waste water from Hanford facilities in the Columbia River under the National Pollution Discharge Elimination System (NPDES) permit were all within the parameter limits on the permit.

1980-04-01

101

Determination of the biodegradation rate of asphalt for the Hanford grout vaults. Hanford Grout Technology Program  

Energy Technology Data Exchange (ETDEWEB)

Testing was initiated in March 1991 and completed in November 1992 to determine the rate at which asphalt is biodegraded by microorganisms native to the Hanford Site soils. The asphalt tested (AR-6000, US Oil, Tacoma, Washington) is to be used in the construction of a diffusion barrier for the Hanford grout vaults. Experiments to determine asphalt biodegradation rates were conducted using three separate test sets. These test sets were initiated in March 1991, January 1992, and June 1992 and ran for periods of 6 months, 11 months, and 6 months, respectively. The experimental method used was one originally developed by Bartha and Pramer (1965), and further refined by Bowerman et al. (1985), that determined the asphalt biodegradation rate through the measurement of carbon dioxide evolved.

1993-04-01

102

Case study: Accelerated schedule for MULTI LIMS installation  

Energy Technology Data Exchange (ETDEWEB)

This presentation focuses on the steps taken by the Westinghouse Hanford Company to meet an accelerated schedule for configuration and implementation of the MULTI LIMS in a multiple laboratory environment. The Westinghouse Hanford Company purchased the MULTI LIMS Laboratory Information Management System in August, 1993. Hardware delivery began in October, 1993. Less than four months later, the initial configuration was released for use in two Westinghouse Hanford Company laboratories. Several major obstacles were overcome during implementation. These include information gathering for base table loading, user training, acceptance of the new system by users of a legacy system, and hardware configuration issues. In summary, steps needed to be taken to meet the accelerated implementation schedule of the MULTI LIMS at the Hanford Site. The obstacles faced were overcome through the in-depth knowledge and help ...

1994-05-01

103

Ventilation on demand: The efficient way to ensure clean air; Bedarfsgeregelte Lueftung: Dicke Luft wirtschaftlich verhindern  

Energy Technology Data Exchange (ETDEWEB)

Ventilation systems must ensure high room air quality with minimum energy consumption in all states of operation. Systems for ventilation on demand are increasing their market share. (orig./MSK) [Deutsch] Oberste Aufgabe von Raumlufttechnischen Anlagen ist die Sicherstellung guter Raumluftqualitaet bei minimalem Energieverbrauch unter allen Betriebsbedingungen. Um dieses Ziel zu erreichen, setzt sich am Markt zunehmend die bedarfsgeregelte Lueftung durch. (orig./MSK)

1997-11-01

104

Ventilation by the windows in classrooms: a case study  

Energy Technology Data Exchange (ETDEWEB)

Four classrooms of two secondary schools located around Lyon in France have been monitored. The objectives are to analyse the quality of the indoor air and the thermal comfort and also the behaviour of the occupants towards opening of the windows. This paper briefly describes the context and the nature of the monitoring campaign, and presents the results of the measurements with direct interpretation of the ventilation needs. Results from this study show that allowable CO{sub 2} levels are overpassed several times in a school day. The presence of a mechanical ventilation system leads to lower peaks but the fresh airflow is too small to prevent an indoor confining, that is also revealed by the aerobiological analysis. (author)

1994-12-31

105

New radioisotope for lung ventilation studies: 19-neon  

Energy Technology Data Exchange (ETDEWEB)

Neon 19, a 17-second positron-emitting radioelement, is produced continously by 23 MeV alpha particle bombardment of oxygen. For a 12 ..mu..A particle current the method of preparation described delivers 14 mCi of neon 19 per min to the functional exploration room. The radiochemically pure radioactive gas is diluted in air and breathed continously by the patient lying under a positron tomographic camera. The regional lung ventilation distribution is obtained on 2 cm thick sections of organ with a transverse resolution of 17 mm. Quantification of the ventilation output per unit lung volume is contemplated.

1980-10-01

106

Hybrid ventilation. Control strategies for hybrid ventilation, consequences for air quality, thermal comfort and energy use; Hybrid ventilasjon  

Energy Technology Data Exchange (ETDEWEB)

This article deals with the need for control strategies and control systems in buildings with hybrid ventilation. In this respect, control strategies are methods of keeping certain parameters like temperature, air quality etc within specified limits. A control system is automatic and includes sensors, motors, dampers etc. The article also discusses consequences with respect to thermal comfort, air quality and energy use following selection of control parameters for controlling air masses.

2001-07-01

107

Possible explosive compounds in the Savannah River Site waste tank farm facilities  

Energy Technology Data Exchange (ETDEWEB)

This report will be revised upon completion of current testing investigating the radiolytic stability of additional energetic materials and the analysis of tank farm samples for volatile and semi-volatile organic compounds.

2000-04-13

108

Charts give vapor loss from internal floating-roof tanks  

Energy Technology Data Exchange (ETDEWEB)

Nomographs have been constructed to estimate the average evaporation loss from internal floating-roof tanks. Loss determined from the charts can be used to evaluate the economics of seal conversion and to reconcile refinery, petrochemical plant, and storage terminal losses. The losses represent average standing losses only. They do not cover losses associated with the movement of product into or out of the tank. The average standing evaporation loss from an internal floating-roof tank depends on: vapor pressure of the product; type and condition of roof seal; tank diameter; and type of fixed roof support. The nomographs can estimate evaporation loss for product true vapor pressures (TVP) ranging from 1.5 to 14 psia, the most commonly used seals for average and tight fit conditions, tank diameters ranging from 50 to 250 ft, welded and bolted designs, and both self-supporting and ...

1987-03-09

109

Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2  

Energy Technology Data Exchange (ETDEWEB)

Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ...

2008-04-15

110

Ventilation test at Mont Terri. Geoelectric monitoring of the opalinus clay desaturation. Phase 2  

International Nuclear Information System (INIS)

Between December 2001 and May 2004, a ventilation experiment (VE) was performed in the Mont Terri Underground Research Laboratory (URL) and co-financed by the Commission of the European Communities. The objective was to investigate the desaturation of consolidated clay formations in consequence of the ventilation of underground openings of a repository in such a formation. The results of the geoelectric measurements performed in the second phase of the Mont Terri ventilation test can be summarized as follows: Geoelectric tomography has been found suitable for monitoring ventilation-induced saturation changes in the Opalinus clay. During ventilation with dry air a desaturation down to below 50% could be detected in both desaturation cycles. The desaturated zone extends less than 0.5 m into the rock around the microtunnel. During the second resaturation phase, ...

111

Revisiting an old hypothesis of human thermal perception: alliesthesia  

British Library Electronic Table of Contents (United Kingdom)

Many new technologies and approaches to the provision of comfort inside buildings such as displacement ventilation, mixed-mode strategies, personally controllable (task-ambient) designs, chilled beams as well as some old but recently fashionable ones such as natural ventilation are prompting a rethink of the accepted comfort wisdom. How can a single combination of thermal environmental parameters be deemed unacceptable in a conventional heating ventilation and air-conditioning setting, and yet be regarded as acceptable, or even pleasant, in a naturally ventilated or mixed-mode setting? Why do current comfort standards prescribe static and isothermal conditions for comfort in one building, and dynamic and spatially variable indoor climates for comfort in another? The phenomenon of alliesthe...

2011-01-01

112

Providing better indoor environmental quality brings economicbenefits  

Energy Technology Data Exchange (ETDEWEB)

This paper summarizes the current scientific evidence that improved indoor environmental quality can improve work performance and health. The review indicates that work and school work performance is affected by indoor temperature and ventilation rate. Pollutant source removal can sometimes improve work performance. Based on formal statistical analyses of existing research results, quantitative relationships are provided for the linkages of work performance with indoor temperature and outdoor air ventilation rate. The review also indicates that improved health and related financial savings are obtainable from reduced indoor tobacco smoking, prevention and remediation of building dampness, and increased ventilation. Example cost-benefit analyses indicate that many measures to improve indoor temperature control and increase ventilation rates will be highly cost effective, with benefit-cost ratios as high ...

2007-06-01

113

Experimental assessment of the velocity and temperature distribution in an indoor displacement ventilation jet  

British Library Electronic Table of Contents (United Kingdom)

Displacement Ventilation (DV) offers a great opportunity to improve indoor air quality while reducing the energy consumption compared to mixing ventilation. A frequent problem with displacement ventilation is however the draft discomfort caused by the cold air movement at foot level and excessive temperature difference between head and ankle. Despite numerous past studies, there is still a lack of detailed data regarding the velocity and temperature distribution inside DV jets. In this experimental study, measurements of the air velocity and temperature are performed in the DV jet produced by a flat wall-mounted DV diffuser, using a fine mesh focused on the 0.00-0.20 m height range. Two supply conditions are studied. Three planes of measurements are covered: the vertical longitudinal plane...

2012-01-01

114

Evaluation of a positive ventilation delivery system (PVDS) in administering technegas to the noncompliant patient  

International Nuclear Information System (INIS)

Full text: Certain groups of patients have been excluded from ventilation lung scanning due to their inability to comply with instruction. Tetley Manufacturing have recently developed a Positive Ventilation Delivery System (PVDS) which assists in delivering Technegas to patients who are unable to cooperate fully. The aim of this study is to evaluate the PVDS in the clinical setting. Fifteen frail aged and psychogeriatric patients (n=l 5), mean age 78 years (range 60-93), were ventilated with Technegas using the PVDS. The decision to ventilate the patient with the PVDS was based on an initial assessment of the patients ability to comply with instructions, or failure of the conventional ventilation method, to produce an adequate count rate. Technegas was prepared in the usual manner and then delivered to the patients lungs by squeezing a black anesthetic bag synchronously with the ...

1998-06-01

115

Estimated costs of ventilation systems complying with the HUD ventilation standard for manufactured homes  

Energy Technology Data Exchange (ETDEWEB)

At the request of the US Department of Housing and Urban Development (HUD), the Pacific Northwest Laboratory estimated the material, labor, and operating costs for ventilation equipment needed for compliance with HUD`s proposed revision to the ventilation standard for manufactured housing. This was intended to bound the financial impacts of the ventilation standard revision. Researchers evaluated five possible prototype ventilation systems that met the proposed ventilation requirements. Of those five, two systems were determined to be the most likely used by housing manufacturers: System 1 combines a fresh air duct with the existing central forced-air system to supply and circulate fresh air to conditioned spaces. System 2 uses a separate exhaust fan to remove air from the manufactured home. The estimated material and labor costs for these two systems range from $200 to $300 per ...

1993-11-01

116

Construction progress of the cooling & ventilation in the LHC project  

CERN Document Server

After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.

2002-01-01

117

Construction Progress of the Cooling and Ventilation in the LHC Project  

CERN Document Server

The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. Finally, a short ...

2001-01-01

118

Calculation of ventilation requirements in the case of intermittent pollution: application to enclosed parking garages  

Energy Technology Data Exchange (ETDEWEB)

The ventilation requirements for decontamination are normally determined with a static calculation method. In some cases, the pollutant emission is intermittent, for example in the car park of an office building, where all the cars enter and leave the place nearly at the same time. Generally, in such a case, the volume of the garage is large, consequently the time constant of the system has a high value. So a static approach would no longer stay accurate and a dynamic evaluation is needed. With the help of some assumptions, calculations remain rather simple and results can be plotted on nomographs or computed on a programmable handheld calculator. The amount of energy saved may appear very large in some cases. A sizing optimization will be required but also remains easy to compute. The paper presents the method of calculation for a single ventilation level and the optimization of a two-level ventilation.

1982-01-01

119

Tank of sodium cooled fast reactor  

International Nuclear Information System (INIS)

Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).

120

Production Data Package 267 Gallon External Fuel Tank  

Science.gov (United States)

... It is recommended that the drawings be validated in accordance with NAVAIRINST 4333.10 and the data package, Appendix A, be used for ...

1973-08-23

121

High-level waste tank modifications, installation of mobilization equipment/check out  

Energy Technology Data Exchange (ETDEWEB)

PUREX high-level waste (HLW) is contained at the West Valley Demonstration Project (WVDP) in an underground carbon-steel storage tank. The HLW consists of a precipitated sludge and an alkaline supernate. This report describes the system that the WVDP has developed and implemented to resuspend and wash the HLW sludge from the tank. The report discusses Sludge Mobilization and Wash System (SMWS) equipment design, installation, and testing. The storage tank required modifications to accommodate the SMWS. These modifications are discussed as well.

1992-08-31

122

Early Season Applications of Fluridone for Control of Curlyleaf ...  

Science.gov (United States)

... While the large tanks served to regulate the water temper- ature, the polypropylene aquaria served as independent experimental units. ...

2010-12-01

123

Polychlorinated Biphenyl Presence in the Columbia River Corridor  

Energy Technology Data Exchange (ETDEWEB)

The U. S. Department of Energy (DOE) is required by Comprehensive Environmental Response, Compensation, and Liability Act of 1980 regulations to develop a conceptual understanding of potential contaminant releases from the Hanford Site based on an evaluation of existing data and known historical practices. Polychlorinated biphenyls (PCBs) are one environmental contaminant potentially released through leaks, spills, or disposal. This document presents a summary of selected relevant existing information, including environmental studies and Hanford Site analytical data.

2007-09-06

124

Neptunium storage at Hanford  

Energy Technology Data Exchange (ETDEWEB)

A decision must be made regarding whether the United State`s stockpile of neptunium should be discarded into the waste stream or kept for the production of Pu-238. Although the cost of long term storage is not inconsequential, to dispose of the material means the closing of our option to maintain control over our Pu-238 stockpile. Within the Fuels and Materials Examination Facility at Hanford there exists a remotely operated facility that can be converted for neptunium storage. This paper describes the facility and the anticipated handling requirements.

1993-06-01

125

Automated remote positioning and examination of FFTF reactor power characterization dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) reactor characterization by the Hanford Engineering Development Laboratory (HEDL) includes extensive neutronic measurements during startup and initial operation. To aid in the handling and counting of the thousands of passive dosimeters used as part of this effort, an automated dosimetry specimen handling, positioning, and counting system was designed and developed by Westinghouse Hanford for the Department of Energy.

1981-05-04

126

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972  

Energy Technology Data Exchange (ETDEWEB)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate that these yearly summaries will be helpful ...

1992-07-01

127

Radioactive contamination of fish, shellfish, and waterfowl exposed to Hanford effluents: Annual summaries, 1945--1972  

International Nuclear Information System (INIS)

The objective of the Hanford Environmental Dose Reconstruction Project (HEDR) is to estimate the potential radiation doses received by people living within the sphere of influence of the Hanford Site. A potential critical pathway for human radiation exposure is through the consumption of waterfowl that frequent onsite waste-water ponds or through eating of fish, shellfish, and waterfowl that reside in/on the Columbia River and its tributaries downstream of the reactors. This document summarizes information on fish, shellfish, and waterfowl radiation contamination for samples collected by Hanford monitoring personnel and offsite agencies for the period 1945 to 1972. Specific information includes the types of organisms sampled, the kinds of tissues and organs analyzed, the sampling locations, and the radionuclides reported. Some tissue concentrations are also included. We anticipate that these yearly summaries will be helpful ...

128

Hanford facility dangerous waste permit application, general information portion  

Energy Technology Data Exchange (ETDEWEB)

The `Hanford Facility Dangerous Waste Permit Application` is considered to be a single application organized into a General Information Portion (this document, DOE/RL-91-28) and a Unit- Specific Portion. The scope of the General Information Portion includes information that could be used to discuss operating units, units undergoing closure, or units being dispositioned through other options. Documentation included in the General Information Portion is broader in nature and could be used by multiple treatment, storage, and/or disposal units. A checklist indicating where information is contained in the General Information Portion, in relation to the Washington State Department of Ecology guidance documentation, is located in the Contents Section. The intent of the General Information Portion is: (1) to provide an overview of the Hanford Facility; and (2) to assist in streamlining efforts associated with treatment, storage, and/or disposal ...

1996-07-29

129

Hanford Site Environmental data for Calendar Year 1990. Surface and Columbia River  

Energy Technology Data Exchange (ETDEWEB)

Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1990 is a summary of offsite and onsite environmental monitoring data collected during 1990 by PNL`s Environmental Monitoring Program. The data summaries included in the annual report were created from individual surface and river monitoring results. This volume ...

1992-01-01

130

Hanford Site Environmental data for Calendar Year 1990  

Energy Technology Data Exchange (ETDEWEB)

Environmental monitoring at the Hanford Site, located in southeastern Washington State, is conducted by Battelle Memorial Institute, Pacific Northwest Division, as part of its contract to operate the Pacific Northwest Laboratory (PNL) for the US Department of Energy. The data collected provide a historical record of radionuclide and radiation levels attributable to natural causes, worldwide fallout, and Hanford operations. Data are also collected to monitor several chemicals. Pacific Northwest Laboratory publishes an annual environmental report for the Hanford Site each calendar year. The Hanford Site Environmental Report for Calendar Year 1990 is a summary of offsite and onsite environmental monitoring data collected during 1990 by PNL's Environmental Monitoring Program. The data summaries included in the annual report were created from individual surface and river monitoring results. This ...

1992-01-01

131

Hanford Cultural Resources Laboratory annual report for fiscal year 1990  

Energy Technology Data Exchange (ETDEWEB)

The Hanford Cultural Resources Laboratory (HCRL) was established by the US Department of Energy Field Office, Richland (RL) in 1987 as part of Pacific Northwest Laboratory. The HCRL provides support for managing the archaeological, historical, and cultural resources of the Hanford Site, Washington, in a manner consistent with federal statutes and regulations. This report summarizes activities of the HCRL during fiscal year (FY) 1990. The HCRL responsibilities have been set forth in the Hanford Cultural Resources Management Plan (HCRMP) as a prioritized list of tasks. The task list guided cultural resources management activities during FY 1990 and is the outline for this report. In order, these tasks were to (1) conduct cultural resource reviews, (2) develop an archaeological resources protection plan, (3) monitor the condition of known archaeological sites, (4) plan a curation system for artifacts and records, (5) evaluate ...

1991-11-01

132

Environmental Restoration Project quality system requirements for the Hanford Site. Revision 3  

International Nuclear Information System (INIS)

This document defines the quality system requirements for the US Department of Energy, Richland Operations Office (DOE-RL), Environmental Restoration (ER) Project at the Hanford Site. The Environmental Restoration Project Quality System Requirements for the Hanford Site integrates quality assurance requirements from the DOE Orders, the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement), the Hanford Facility Resource Conservation and Recovery Act of 1976 (RCRA) Permit, and applicable Federal and Washington State regulations. This document, based on ten criteria, provides user organizations with the flexibility to incorporate only those criteria and paragraphs applicable to their specific scopes of work. The requirements of this document are to be applied based on a graded approach that takes into consideration the risk inherent in, as well as the importance of, specific items, ...

133

Vortex control of safety enclosures  

International Nuclear Information System (INIS)

The vortex amplifier controller has no moving parts and therefore it can have extremely high reliability and avoid the maintenance problems associated with contaminated equipment. The vortex amplifier and its application to ventilation control of radioactive enclosures is described. Reverse purge vortex amplifier ventilation system control is also discussed. (U.K.).

134

Ventilation intensity - Influence on the air quality and its calculation method; Die Lueftungsintensitaet - Auswirkung auf die Luftqualitaet und deren Berechnungsmethoden  

Energy Technology Data Exchange (ETDEWEB)

Because of good thermal insulation of advanced energetic buildings and their good airtightness the air hygiene is insufficient. A normal ventilation behaviour by window opening consumes too much heating energy. A calculation method is shown taking into account a required air change number, flow rate and indoor air quality as thermal comfort in the rooms occupied by different number of persons. (GL)

2006-07-01

135

Super-ventilation in commercial buildings; Surventilation des locaux tertiaires  

Energy Technology Data Exchange (ETDEWEB)

The preliminary results of a feasibility study of nighttime and/or daytime accelerated ventilation for reducing or even avoiding air conditioning energy consumption in commercial buildings, is presented. The first part of the study is based on computerized simulations and in-situ experimentations which are described. The second part is aimed at determining technological limitations to the various components and optimizing building environmental quality in terms of energy conservation, acoustics and air quality

1995-09-01

136

Current ventilation and air conditioning systems and strategies  

Energy Technology Data Exchange (ETDEWEB)

The report examines common ventilation and air conditioning systems and strategies for both domestic and commercial buildings; and covers issues such as energy conservation, indoor air quality and occupant comfort. Drawing data from many countries in Europe and the United States of America, various natural, mechanical and air conditioning systems were compared using criteria such as climate, level of occupant interaction, and level of system comfort. This classification system is evaluated and seen as a valuable framework for further research. (U.K.)

1994-02-01

137

Federal Facility Agreement plans and schedules for liquid low-level radioactive waste tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

Although the Federal Facility Agreement (FFA) addresses the entire Oak Ridge Reservation, specific requirements are set forth for the liquid low-level radioactive waste (LLLW) storage tanks and their associated piping and equipment, tank systems, at ORNL. The stated objected of the FFA as it relates to these tank systems is to ensure that structural integrity, containment and detection of releases, and source control are maintained pending final remedial action at the site. The FFA requires that leaking LLLW tank systems be immediately removed from service. It also requires the LLLW tank systems that do not meet the design and performance requirements established for secondary containment and leak detection be either upgraded or replaced. The FFA establishes a procedural framework for implementing the environmental laws. For the LLLW tank systems, this framework ...

1992-03-01

138

Water Retention Capacity of Argillite from the VE Test - Phase II at Mont Terri: Effect of Ventilation  

International Nuclear Information System (INIS)

The VE (ventilation) test carried out at the Mont Terri underground laboratory in Switzerland intended to evaluate in situ the behaviour of a consolidated clay formation when subjected to alternate periods of flow of wet and dry air during several months. For that, a 10-m gallery was excavated in the Opalinus Clay formation and carefully instrumented. Before and after a second ventilation phase boreholes were drilled. Samples were taken from the drill cores and were analysed from mineralogical and geochemical points of view. Also, the retention curves of these samples were determined in the laboratory following drying paths performed under free volume conditions at 20 degree centigrade, what is the content of this report. Although there are not large differences in the WRC of samples taken from different boreholes, at different distances from the gallery wall or before or after ventilation, those samples taken near the ...

2010-11-01

139

Natural or unnatural ventilation? Sustainable environmental management in non-residential buildings  

Energy Technology Data Exchange (ETDEWEB)

Recent interest in ecologically sustainable design (ESD) has once more focussed attention upon environmental management in buildings. This paper explores the application of both air conditioning and natural ventilation in creating more sustainable non-residential buildings. In the non-residential sector the level of debate surrounding sustainable forms of environmental control and management has been disappointing. It has largely been based upon the rather simplistic argument that air conditioning is bad and natural ventilation is good and thus the only sustainable solution is naturally ventilated buildings. The paper advances the view that for both designers and managers of buildings the problem is more complex than a simple choice between air conditioning and natural ventilation. It begins with a reassessment of conventional ideas of thermal comfort and the organization of the workplace and argues ...

1995-12-31

140

Environmental releases for calendar year 1997  

Energy Technology Data Exchange (ETDEWEB)

This report fulfills the annual environmental release reporting requirements of US Department of Energy (DOE) Order 5400.1. This report provides supplemental information to the Hanford Site Environmental Report (PNNL-11795). The Hanford Site Environmental Report provides an update on the environmental status of the Hanford Site. The sitewide annual report summarizes the degree of compliance with applicable environmental regulations and informs the public concerning the impact of Hanford Site operations on the surrounding environment. Like the Hanford Site Environmental Report, this annual report presents a summary of the environmental releases from facilities and activities managed by the Fluor Daniel Hanford, Incorporated (FDH), and Bechtel Hanford, Incorporated (BHI). In addition to the summary data, this report also includes detailed data ...

1998-08-25

141

Realization of good indoor climate in low-energy office  

Energy Technology Data Exchange (ETDEWEB)

Good indoor air quality and thermal comfort, as well as low energy consumption, were achieved in an environment friendly experimental METOP-office building in Espoo, Finland. The consumption of heating and cooling energy was minimized by installation of energy-efficient windows, good CFC-free thermal insulation of the building envelope, the individually-controlled ventilation and room temperatures, heat recovery and energy-storing structures. According to the study carried out in 1990-1993, the heating energy was 13 kWh/m{sup 3}, 60% lower than the average consumption. The index of the satisfaction of thermal comfort was over 90%. Concentrations of all the measured indoor air pollutants were low. Ventilation rates could be chosen in each office room from 10 to 40 dm{sup 3}/s. The noise level of the ventilation system was low and the lighting level was pleasant. (author)

1994-12-31

142

IEA Annex 27. Assessment of air quality, comfort and sound of ventilation systems in houses; IEA Annex 27. Beoordeling van woningventilatiesystemen op luchtkwaliteit, comfort en geluid  

Energy Technology Data Exchange (ETDEWEB)

In the international study of IEA Annex 27 `Demonstration and evaluation of domestic ventilation systems` a number of simple tools to gain insight into the characteristics of ventilation systems for dwellings are presented. The assessment is made with respect to e.g. indoor air quality, comfort, noise, energy, costs and reliability. In three articles the results of Annex 27 will be discussed. In the first article background information of IEA Annex 27 was given as well as applications in the Netherlands. In this second article attention is paid to the assessment models (`simplified tools`) for indoor air quality, thermal comfort and noise. 6 refs.

1999-09-01

143

Healthy room air - the new Thermal Insulation Ordinance creates a demand for domestic ventilation systems; Gesunde Raumluft - die neue WSchVO weckt den Bedarf an Wohnungslueftungen  

Energy Technology Data Exchange (ETDEWEB)

Mechanical ventilation in private homes was for many years a stepchild of air conditioning engineers. A decisive impulse for change came in January 1995 with the enactment of the new Thermal Insulation Ordinance which for the first time allows house owners to exceed the usual admissible annual heating requirement by a certain amount on the condition that they equip the house with mechanical ventilation systems. (orig.) [Deutsch] Ueber lange Jahre war die mechanische Wohnungslueftung ein Stiefkind der Raumlufttechnik. Einen entscheidenden Impuls gab erst die seit Januar 1995 gueltige Waermeschutzverordnung, die erstmals zulaesst, dass ein gewisses Quantum des Jahres-Heizwaermebedarfs durch den Einbau mechanischer Wohnungslueftungen kompensiert werden kann. (orig.)

1996-10-01

144

CO and CO2 emissions from spontaneous heating of coal under different ventilation rates  

British Library Electronic Table of Contents (United Kingdom)

Carbon monoxide (CO) and carbon dioxide (CO2) emissions during a spontaneous heating event in a coal mine are important gases to monitor for detecting the spontaneous heating at an early stage. However, in underground coal mines, the CO and CO2 concentrations and their related fire ratios may be affected by mine ventilation. In this study, CO and CO2 emissions from spontaneous heating of a U.S. coal sample were evaluated in an isothermal oven under different airflow ventilation rates ranging from 100 to 500cm^3/min. Laboratory experiments were conducted at oven temperatures of 70, 90, and 100^oC. The temperature at the center of the coal sample was continually monitored, while the CO, CO2, and oxygen (O2) concentrations of the exit gas were continually measured. The results indicate that C...

2011-01-01

145

Development of a solvent extraction process for cesium removal from SRS tank waste  

International Nuclear Information System (INIS)

An alkaline-side solvent extraction process was developed for cesium removal from Savannah River Site (SRS) tank waste. The process was invented at Oak Ridge National Laboratory and developed and tested at Argonne National Laboratory using singlestage and multistage tests in a laboratory-scale centrifugal contactor. The dispersion number, hydraulic performance, stage efficiency, and general operability of the process flowsheet were determined. Based on these tests, further solvent development work was done. The final solvent formulation appears to be an excellent candidate for removing cesium from SRS tank waste.

2001-06-30

146

Anaerobic fermenter-decanter for the purification of residual water from sugar refineries, with recovery of combustible methane  

Energy Technology Data Exchange (ETDEWEB)

An anaerobic fermenter-decanter for the purification of residual water from the sugar industry, with recovery of methane, consists of a tank with inclined walls, with a central agitator on a vertical shaft. A flexible cover anchored by its periphery to the walls of the tank and totally submerged forms a collecting pocket for the fermentation gases. The water to be purified is introduced, after being heated to about 35, towards the bottom of the tank near the agitator. A metal collecting bell with submerged edges and with the shaft of the agitator passing axially through it is connected by its edges to a central opening of the cover. The purification yields may exceed 90%.

1981-10-06

147

T Plant secondary containment and leak detection upgrades  

Energy Technology Data Exchange (ETDEWEB)

The W-259 project will provide upgrades to the 2706-T/TA Facility to comply with Federal and State of Washington environmental regulations for secondary containment and leak detection. The project provides decontamination activities supporting the environmental restoration mission and waste management operations on the Hanford Site.

1995-10-19

148

Mixed waste solidification testing on polymer and cement-based waste forms in support of Hanford`s WRAP 2A facility  

Energy Technology Data Exchange (ETDEWEB)

A testing program has been conducted by the Westinghouse Hanford Company to confirm the baseline waste form selection for use in Waste Receiving and Processing (WRAP) Module 2A. WRAP Module 2A will provide treatment required to properly dispose of containerized contact-handled, mixed low-level waste at the US Department of Energy Hanford Site in south-central Washington State. Solidification/stabilization has been chosen as the appropriate treatment for this waste. This work is intended to test cement-based, thermosetting polymer, and thermoplastic polymer solidification media to substantiate the technology approach for WRAP Module 2A. Screening tests were performed using the major chemical constituent of each waste type to measure the gross compatibility with the immobilization media and to determine formulations for more detailed testing. Surrogate materials representing each of the eight waste types were prepared in the laboratory. These ...

1993-10-01

149

Methodology used to compute maximum potential doses from ingestion of edible plants and wildlife found on the Hanford Site  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this report is to summarize the assumptions, dose factors, consumption rates, and methodology used to evaluate potential radiation doses to persons who may eat contaminated wildlife or contaminated plants collected from the Hanford Site. This report includes a description of the number and variety of wildlife and edible plants on the Hanford Site, methods for estimation of the quantities of these items consumed and conversion of intake of radionuclides to radiation doses, and example calculations of radiation doses from consumption of plants and wildlife. Edible plants on the publicly accessible margins of the shoreline of the Hanford Site and Wildlife that move offsite are potential sources of contaminated food for the general public. Calculations of potential radiation doses from consumption of agricultural plants and farm animal products are made routinely and reported annually for those produced offsite, ...

1990-10-01

150

Hanford low-level waste process chemistry testing data package  

Science.gov (United States)

Recently, the Tri-Party Agreement (TPA) among the State of Washington Department of Ecology, U.S. Department of Energy (DOE) and the US Environmental Protection Agency (EPA) for the cleanup of the Hanford Site was renegotiated. The revised agreement specifies vitrification as the encapsulation technology for low level waste (LLW). A demonstration, testing, and evaluation program underway at Westinghouse Hanford Company to identify the best overall melter-system technology available for vitrification of Hanford Site LLW to meet the TPA milestones. Phase I is a {open_quotes}proof of principle{close_quotes} test to demonstrate that a melter system can process a simulated highly alkaline, high nitrate/nitrite content aqueous LLW feed into a glass product of consistent quality. Seven melter vendors were selected for the Phase I evaluation: joule-heated melters from GTS Duratek, Incorporated (GDI); Envitco, Incorporated (EVI); ...

1996-03-01

151

Concentrations of radionuclides in terrestrial vegetation on the Hanford site of potential interest to Native Americans  

Energy Technology Data Exchange (ETDEWEB)

Concentrations of {sup 90}Sr and {sup 137}Cs in Carey`s balsamroot (Balsamorhiza careyana) and Gray`s desert parsley (Lomatium grayi) were similar to concentrations observed in other plants collected on the Hanford Site and from offsite locations surrounding the Site as part of annual Hanford Site surveillance. Observed concentrations may be attributed to historic fallout more than to Hanford Site emissions, although the observation that 200 Area plants had slightly higher concentrations of {sup 137}Cs than 100 Area plants is consistent with other monitoring data of radioactivity in soil and vegetation collected onsite. The present concentrations of {sup 90}Sr and {sup 137}Cs in balsamroot and parsley fluctuate around background levels with some of the higher observed concentrations of {sup 90}Sr found on the Fitzner/Eberhardt Arid Lands Ecology (ALE) Reserve. Analytical results and summary statistics by species and ...

1995-03-01

152

Characterization and remediation of highly radioactive contaminated soil at Hanford  

Energy Technology Data Exchange (ETDEWEB)

The Hanford Site, Richland, Washington, contains over 1,500 identified waste sites and numerous groundwater plumes that will be characterized and remediated over the next 30 years. As a result of the Hanford Federal Facility Agreement and Consent Order, the US Department of Energy (DOE) has initiated a remedial investigation/feasibility study (RI/FS) at the 200-BP-1 operable unit. The 200-BP-1 RI/FS is the first Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) investigation on the Hanford Site that involves highly radioactive and chemically contaminated soils. The initial phase of site characterization was designed to assess the nature and extent of contamination associated with the source waste sites within the 200-BP-1 operable unit. Characterization activities consisted of drilling and sampling, chemical and physical analysis of samples, and development of a conceptual vadose zone model. ...

1993-09-01

153

Vented Bomb Tests to Characterize Propellant and ...  

Science.gov (United States)

... Two types of combustible cartridge cases, post impregnated (PI) and beater additive (B/A) are available for the 120 mm tank gun system. ...

1990-08-01

154

Tanks Versus Infantry in a Smoke Environment (TISE)  

Science.gov (United States)

... INFANTRY PARTIPI ACT 278 DATA POINTS 60 48 ... Page 21. 29 TISE HISTOGRAN-CUN CURUE INFANTRY PARTIP2 EST 895 DATA POINTS ...

1978-08-01

155

Tank 241-AZ-101 Mixer Pump Test Vapor Sampling and Analysis Plan  

Energy Technology Data Exchange (ETDEWEB)

This sampling and analysis plan (SAP) identifies characterization objectives pertaining to sample collection, laboratory analytical evaluation, and reporting requirements for vapor samples obtained during the operation of mixer pumps in tank 241-AZ-101. The primary purpose of the mixer pump test (MPT) is to demonstrate that the two 300 horsepower mixer pumps installed in tank 241-AZ-101 can mobilize the settled sludge so that it can be retrieved for treatment and vitrification. Sampling will be performed in accordance with Tank 241-AZ-101 Mixer Pump Test Data Quality Objective (Banning 1999) and Data Quality Objectives for Regulatory Requirements for Hazardous and Radioactive Air Emissions Sampling and Analysis (Mulkey 1999). The sampling will verify if current air emission estimates used in the permit application are correct and provide information for future air permit applications.

2000-04-10

156

Root Cause Analysis, Tank Fire Problem, M1A1 Main Battle ...  

Science.gov (United States)

... ammunition is stored. Combustible cartridge cases could absorb moisture, swell, and not chamber properly. Additionally, moisture ...

1989-02-01

157

Results of 1995 characterization of Gunite and Associated Tanks at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

This technical memorandum (TM) documents the 1995 characterization of eight underground radioactive waste tanks at Oak Ridge National Laboratory (ORNL). These tanks belong to the Gunite and Associated Tanks (GAAT) operable unit, and the characterization is part of the ongoing GAAT remedial investigation/feasibility study (RI/FS) process. This TM reports both field observations and analytical results; analytical results are also available from the Oak Ridge Environmental Information System (OREIS) data base under the project name GAAT (PROJ-NAME = GAAT). This characterization effort (Phase II) was a follow-up to the {open_quotes}Phase I{close_quotes} sampling campaign reported in Results of Fall 1994 Sampling of Gunite and Associated Tanks at the Oak Ridge National Laboratory, Oak Ridge, Tennessee, ORNL/ER/Sub/87-99053/74, June 1995. The information contained here should be used in conjunction with that ...

1996-02-01

158

Petroleum storage tank cleaning using commercial microbial culture products  

Energy Technology Data Exchange (ETDEWEB)

The removal of paraffinic bottom accumulations from refinery storage tanks represents an increasingly costly area of petroleum storage management. Microorganisms can be used to reduce paraffinic bottoms by increasing the solubility of bottom material and by increasing the wax-carrying capacity of carrier oil used in the cleaning process. The economic savings of such treatments are considerable. The process is also intrinsically safer than alternative methods, as it reduces and even eliminates the need for personnel to enter the tank during the cleaning process. Both laboratory and field sample analyses can be used to document changes in tank material during the treatment process. These changes include increases in volatile content and changes in wax distribution. Several case histories illustrating these physical and chemical changes are presented along with the economics of treatment.

1995-12-31

159

Influence of anchor behaviour on the earthquake response of liquid storage tanks  

International Nuclear Information System (INIS)

The dynamic response of thin liquid storage tanks to earthquakes is a very complicated phenomenon, because it can be highly non linear. Among others, one can meet material and geometric non linearities of the tank shell leading eventually to static or dynamic buckling non linear behavior of anchor bolts, contact non-linearities due to the uplift of the tank base and to the unilateral character of the fluid pressure on the shell and high amplitude fluid oscillations. Moreover, linear or non linear soil structure interaction affects considerably the response of the fluid structure system under consideration. In this paper we focus attention on problems related only to the base uplift and anchors plastification. We study a tank similar to the Hualien project tank, but we neglect the soil structure interaction. The studied tank is representative of medium height to ...

160

Handbook on Ground Forces Attrition in Modern Warfare  

Science.gov (United States)

... 129 US Armored Division Casualty and Tank Loss Rates ..... 132 British Casualty and rank Loss Rates in Operation "Goodwood" . 134 Page 5. ...

1986-09-01

161

Fish waste - NASA Quest  

Science.gov (United States)

Seriously, generally fish waste does drop, but quite slowly. But a good group of snails should still do a fine job of cleaning the tank. ...

162

Demonstration experiments of volume measurement technique for large scale input accountancy tank  

International Nuclear Information System (INIS)

Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)

2000-12-07

163

Absorption of carbon dioxide in waste tanks  

International Nuclear Information System (INIS)

Air flow rates and carbon dioxide concentrations of air entering and exiting eight H-Area waste tanks were monitored for a period of one year. The average instanteous concentration of carbon dioxide in air is within the range reported offsite, and therefore is not affect by operation of the coal-fired power plant adjacent to the tank farm. Waste solutions in each of the tanks were observed to be continuously absorbing carbon dioxide. The rate of absorption of carbon dioxide decreased linearly with the pH of the solution. Personnel exposure associated with the routine sampling and analysis of radioactive wastes stored at SRP to determine the levels of corrosion inhibitors in solution could be reduced by monitoring the absorption of carbon dioxide and using the relationship between pH and carbon dioxide absorption to determine the free hydroxide concentration in solution.

1987-09-01

164

Waste Management Project fiscal year 1998 multi-year work plan, WBS 1.2  

Energy Technology Data Exchange (ETDEWEB)

The Waste Management Project manages and integrates (non-TWRS) waste management activities at the site. Activities include management of Hanford wastes as well as waste transferred to Hanford from other DOE, Department of Defense, or other facilities. This work includes handling, treatment, storage, and disposal of radioactive, nonradioactive, hazardous, and mixed solid and liquid wastes. Major Waste Management Projects are the Solid Waste Project, Liquid Effluents Project, and Analytical Services. Existing facilities (e.g., grout vaults and canyons) shall be evaluated for reuse for these purposes to the maximum extent possible.

1997-09-23

165

Information on Hanford site cribs and septic systems  

Energy Technology Data Exchange (ETDEWEB)

This document provides information on septic systems with a design capacity of greater than 14,500 gal/d and cribs submitted as requested by the Washington State Department of Ecology. Data for this submittal were taken from the Waste Information Database System (WIDS) and the Hanford Environmental Compliance Record (HECR) database. The current definition used in WIDS for an ''inactive facility'' is one that either no longer receives waste or plans to in the future. Information concerning the deactivation method for a facility is included when such information is available.

1988-05-01

166

Environmental restoration remedial action quality assurance requirements document  

International Nuclear Information System (INIS)

The environmental Restoration Remedial Action Quality Assurance Requirements Document (DOE/RL 90-28) defines the quality assurance program requirements for the US Department of Energy-Richland Field Office Environmental Restoration Remedial Action Program at the Hanford Site, Richland, Washington. This paper describes the objectives outlined in DOE/RL 90-28. The Environmental Restoration Remedial Action Program implements significant commitments made by the US Department of Energy in the Hanford Federal Facility Agreement and Consent Order entered into with the Washington State Department of Ecology and the US Environmental Protection Agency.

1991-09-08

167

Who Should Receive Life Support During a Public Health Emergency? Using Ethical Principles to Improve Allocation Decisions  

UK PubMed Central (United Kingdom)

A public health emergency such as an influenza pandemic will lead to shortages of mechanical ventilators, critical care beds, and other potentially life saving treatments. This will raise difficult...Full Text Available

2009-01-20

168

Sealant tests to control radon emanation in a uranium mine. Open file report sep 79-dec 81  

International Nuclear Information System (INIS)

This report describes a field-test program to determine the effectiveness of a polymeric wall sealant to reduce the escape of naturally occurring radioactive gas radon from the walls of an underground uranium mine into the ventilation air.

169

Remote environmental monitoring at No. 26 Colliery  

Energy Technology Data Exchange (ETDEWEB)

The author describes the layout of the environmental monitoring scheme at Devco's No. 26 Colliery in Canada, which includes wall face ventilation, fan performance, and methane drainage monitoring. He gives details of the sensors, outstations, and the surface control room.

1982-03-01

170

Principles of room air flow; Grundlagen der Raumluftstroemung  

Energy Technology Data Exchange (ETDEWEB)

The following subjects are dealt with: physics of indoor air flow, flow in individual rooms, exchange of air and pollution between individual building zones and with the outside world, thermal coupling with the building shell, thermal comfort and air quality, evaluation of the ventilation. figs., tabs., refs.

1994-12-31

171

In-depth industrial-hygiene survey report of the Bunge Corporation, Kansas City, Kansas  

Science.gov (United States)

Potential exposure of workers to phosphide was examined during an in-depth industrial hygiene survey at the Bunge Corporation, in Kansas City, Kansas, where the gas was used as a grain fumigant. During the study, 14 men were employed at the facility. Tablets of aluminum phosphide were added to the grain mass for fumigation. General dilution ventilation resulted from outside air entering the work areas through ventilation louvers; there was also a local-exhaust ventilation system. Air samples revealed that, when the fumigant dispensers were being filled, workers in the area had significant exposure. At the time of the survey the relative humidity in the facility was high, permitting the reaction to phosphide to occur more readily. The levels of phosphide and respirable dust were reasonably low in the elevators, suggesting that the ventilation system was adequate. The author recommends that workers ...

1986-09-01

172

Impact of intraoperative lung-protective interventions in patients undergoing lung cancer surgery  

UK PubMed Central (United Kingdom)

IntroductionIn lung cancer surgery, large tidal volume and elevated inspiratory pressure are known risk factors of acute lung (ALI). Mechanical ventilation with low tidal volume...Full Text Available

2009-01-01

173

Free air flows for the removal of pollutants from car parks; Air-conditioning systems without sheet metal ducts as an alternative to transverse ventilation with sheet-metal ducts. Pt. 1. Freie Luftstroemungen entsorgen Parkraeume; RLT-Anlagen ohne Blechkanaele als Alternative zur Querlueftung mit Blechkanaelen. T. 1  

Energy Technology Data Exchange (ETDEWEB)

In car parks of considerable length, the removal of exhaust emissions, is carried out by air-conditioning systems mainly through transverse ventilation over short routes. The required air-conditioning ducts frequently produce a reduction in the available parking space simply due to their presence, resulting in restrictive effects on the level of acceptance by the users. In such cases, remedial action can be taken by creating ductless longitudinal ventilation. Depending on the required room air quality in the zones with the highest level of pollution, the volumetric flows for longitudinal disposal are no greater than those for conventional transverse ventilation. In conjunction with architecturally clear and positive lighting designs, clearly laid out car parks with a friendly atmosphere can be created which the user will be pleased to accept. (orig./BWI)

1994-03-01

174

Environmental effects and energy efficiency in building design: A green building approach. Part 1, energy efficiency techniques. Research report  

Energy Technology Data Exchange (ETDEWEB)

;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

175

Environmental Effects and Energy Efficiency in Building Design: A Green Building Approach. Part 1, Energy Efficiency Techniques.  

Science.gov (United States)

Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.

1993-01-01

176

Diesel equipment: is it safe to use underground  

Energy Technology Data Exchange (ETDEWEB)

Research indicates that diesel equipment can be used safely in undergound coal mines provided that certain conditions prevail. These conditions are: the machines and engines are approved for underground use, an adequate maintenance and training program is in effect, an adequate monitoring system with proper instrumentation is used, and adequate ventilation is maintained.

1984-04-01

177

Ventilation concept, indoor air quality and measurement results in the ``Passivhaus Kranichstein``  

Energy Technology Data Exchange (ETDEWEB)

The ``Passivhaus Darmstadt-Kranichstein`` is a 4 unit terrace house with an extremely low total annual energy consumption of less than 32 kWh/m{sup 2} of living area, thereof about 12 kWh are needed for room heating. The determining factors for the low consumption are the superinsulation, airtightness of the thermal envelope in combination with a highly efficient VAV ventilation system, and an improved window construction. The results of a detailed monitoring program allow decisive statements concerning reduction of energy consumption, relief of environment, indoor air quality, and thermal comfort. (author)

1994-12-31

178

Unified requirements for monitoring of ventilation of drifts in coal and shale mines  

Energy Technology Data Exchange (ETDEWEB)

Ventilation of blind drifts in the Karaganda Basin because of the high release of methane is a very important task. As indicated by measurements in 116 blind drifts, on the average the magnitude of air velocity in the pipelines VPM is in limits of 15-25 m/sec. The DPV-1 sensor encompasses almost the entire range of velocities of air motion. Operation of the DPV-1 sensors at mines of the production association ''Karaganda-ugol''' confirmed their high reliability and convenience for operation.

1982-01-01

179

The new thermal comfort equation to qualify air in buildings. De nieuwe behaaglijkheidsbalans voor de kwaliteit van de lucht in gebouwen  

Energy Technology Data Exchange (ETDEWEB)

In the 1988 February issue of this magazine the units olf and decipol were introduced. Olf is a measure for the pollution load and decipol for the indoor air quality. This article discusses a new ventilation theory which is quantified by the new indoor air quality thermal comfort balance based on the units olf and decipol. This balance requires more ventilation air than for the present regulations. It takes into account all pollution sources. 2 figs., 9 refs., 3 tabs.

1990-05-01

180

Displacement ventilation in industry - a design principle for improved air quality  

Energy Technology Data Exchange (ETDEWEB)

There is very little quantitative documentation of actual improvements resulting from the installation of new general ventilation systems in industrial settings. Therefore the performance of the common mixing design principle was compared to the displacement design principle by means of an intervention study in a workshop (V = 12,000 m[sup 3]), where thermoplastics were moulded. An experimental signal-response tracer gas technique was used. In terms of supplying fresh air to the zone of occupancy the displacement system was better than the mixing system by a factor of 2. In terms of the exposure level to a simulated contaminant (tracer gas) the displacement system was better by a factor 1.5-18. (author)

1992-10-01

181

Dampers, fluidics and the failsafe fallacy [fire protection  

International Nuclear Information System (INIS)

The fire protection practices adopted at nuclear power stations generally follow the well established principles used throughout industry. Unfortunately, there is one particular area - the interaction with heating, ventilation and air conditioning (HVAC) services - where nuclear power stations pose a seemingly insoluble conflict: that between the need to contain and the need to ventilate. Now, however, solid state fire dampers using power fluidics may promise a solution. One of the key characteristics of a fluidic device is that it is 'solid state', i.e. it has no moving parts. Because of this, its inherent reliability is orders of magnitude greater than a mechanical device. (U.K.).

182

A conceptual model for laboratory ventilation greenhouse gas planning  

British Library Electronic Table of Contents (United Kingdom)

There is increasing pressure to operate laboratory facilities in environmentally and financially sustainable ways. A key factor in achieving this goal is careful consideration of how energy is used by the buildings' ventilation system, both for conditioning air supplied to the laboratories and the energy used moving air through the building. Traditionally, laboratory energy use is treated as an engineering concern within the scope of the building's overall design and operation. However, this approach limits the involvement of key stakeholders in many important decisions and can lead to unexpected safety concerns for the laboratory's users. We believe that a broad view of the parties affected by a laboratory building's operations is necessary to avoid having the various stakeholders working...

2011-01-01

183

Analysis of thermal comfort and indoor air quality in a mechanically ventilated theatre  

Energy Technology Data Exchange (ETDEWEB)

Theatres are the most complex of all auditorium structures environmentally. They usually have high heat loads, which are of a transient nature as audiences come and go, and from lighting which changes from scene to scene, and they generally have full or nearly full occupancy. Theatres also need to perform well acoustically, both for the spoken word and for music, and as sound amplification is less used than in other auditoria, background noise control is critically important. All these factors place constraints on the ventilation design, and if this is poor, it can lead to the deterioration of indoor air quality and thermal comfort. To analyse the level of indoor air quality and thermal comfort in a typical medium-sized mechanically ventilated theatre, and to identify where improvements could typically be made, a comprehensive post-occupancy evaluation study was carried out on a theatre in Belgrade. The evaluation, based on the results of ...

2008-07-01

184

W-12 valve pit decontamination demonstration  

Energy Technology Data Exchange (ETDEWEB)

Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would ...

1995-12-01

185

Realistic Probability Estimates For Destructive Overpressure Events In Heated Center Wing Tanks Of Commercial Jet Aircraft  

Energy Technology Data Exchange (ETDEWEB)

The Federal Aviation Administration (FAA) identified 17 accidents that may have resulted from fuel tank explosions on commercial aircraft from 1959 to 2001. Seven events involved JP 4 or JP 4/Jet A mixtures that are no longer used for commercial aircraft fuel. The remaining 10 events involved Jet A or Jet A1 fuels that are in current use by the commercial aircraft industry. Four fuel tank explosions occurred in center wing tanks (CWTs) where on-board appliances can potentially transfer heat to the tank. These tanks are designated as ''Heated Center Wing Tanks'' (HCWT). Since 1996, the FAA has significantly increased the rate at which it has mandated airworthiness directives (ADs) directed at elimination of ignition sources. This effort includes the adoption, in 2001, of Special Federal Aviation Regulation 88 of 14 CFR part 21 ...

2007-02-07

186

High-level waste storage tank farms/242-A evaporator Standards/Requirements Identification Document (S/RID), Volume 2  

Energy Technology Data Exchange (ETDEWEB)

The High-Level Waste Storage Tank Farms/242-A Evaporator Standards/Requirements Document (S/RID) is contained in multiple volumes. This document (Volume 2) presents the standards and requirements for the following sections: Quality Assurance, Training and Qualification, Emergency Planning and Preparedness, and Construction.

1994-04-01

187

Development of an experimental installation for short-lived isotopes production in INR linac  

International Nuclear Information System (INIS)

A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.

2010-01-01

188

DOUBLE-SHELL TANK (DST) HYDROXIDE DEPLETION MODEL FOR CARBON DIOXIDE ABSORPTION  

International Nuclear Information System (INIS)

This document generates a supernatant hydroxide ion depletion model based on mechanistic principles. The carbon dioxide absorption mechanistic model is developed in this report. The report also benchmarks the model against historical tank supernatant hydroxide data and vapor space carbon dioxide data. A comparison of the newly generated mechanistic model with previously applied empirical hydroxide depletion equations is also performed.

2009-04-30

189

Sodium leak detector  

International Nuclear Information System (INIS)

Purpose: To permit accurate detection of sodium leakage by distinguishing between variations in the overflow tank level due to changes in sodium temperature accompanying changes in the power level or operating state of a liquid metal sodium cooled fast breeder, and a reduction in power level due to duct leakage. Constitution: The volume of sodium in the primary cooling system is roughly estimated from the temperatures of hot and cold legs, and the duct leak preset level with respect to the sodium liquid level within an overflow tank when the plant is normal is varied according to the state of the plant. More particularly, the volume of sodium within the overflow tank is calculated on the basis of a signal representing the liquid level detected by a liquid level gauge in the overflow tank and a signal representing the temperature detected by hot leg and cold leg thermometers, thereby obtaining the preset ...

190

Performance evaluation of corrosion probes in simulated WVNS tank 8D-2 waste: WVNS tank farm process support  

Energy Technology Data Exchange (ETDEWEB)

Five corrosion probes were received from West Valley Nuclear Services for evaluation in simulated tank 8D-2 3rd-stage sludge wash slurry. The same waste slurry simulated was also used in a series of ongoing corrosion studies assessing the effects of in-tank sludge washing on the integrity of tank 8D-2. Two of the corrosion probes were installed in the coupon corrosion test vessels operating at {approximately}150{degrees}F to compare performance of the probes with that observed by coupon tests conducted in the same vessels. Corrosion rate data calculated from electrical resistance measurements of the corrosion probes were evaluated for this study using two slightly different approaches. One approach uses the total length of exposure of the probe to give a ``time-averaged`` value of the corrosion rate. The other approach uses a shorter period of time (relative to the length of the test) in the calculation of corrosion rate, ...

1994-07-01

191

Numerical flow simulation in ship and ocean engineering; Senpaku kaiyo suiri bun`ta deno ryutai suchi simulation  

Energy Technology Data Exchange (ETDEWEB)

The improvement in the functions of the viscous flow calculation method VEGA-SHIP around a ship and the expansion of application range were described as the numerical flow simulation in ship and ocean engineering and at the same time application examples to the ocean engineering by the general-purpose flow simulation code FLOW-3D handling the non-steady flow with a free surface were introduced as the numerical simulation regarding such products as a water gate and a dam. In the VEGA-SHIP, water surface was handled as a fixed wall so that wave could not be calculated. Therefore, an algorithm for calculating wave on the water surface was added to the VEGA-SHIP and a calculation method simultaneously considering the creation of wave around the ship and viscosity was developed. The FLOW-3D was used to calculate the phenomenon where inside liquid moved greatly due to the oscillation of a tank and hit against and damaged the tank ceiling in the ...

1995-01-01

192

Laboratory studies of gas generation and potential for tank wall corrosion during blending of high-level wastes at the West Valley Demonstration Project  

Energy Technology Data Exchange (ETDEWEB)

Laboratory experiments were conducted to simulate the transfer of acidic THOREX waste from Tank 8D-4 into the alkaline PUREX waste in Tank 8D-2 at West Valley. The purpose of the experiments was to explore means of minimizing the production of nitric oxide (NO) gas during mixing of the two wastes and to assess the potential for the gas to further react in the vapor space possibly leading to enhanced corrosion of the tank walls. Forty one THOREX/PUREX mixing tests were conducted to explore the effects of stirring rate, pH, THOREX addition rate, THOREX or PUREX dilution, and temperature. The two most important criteria for minimizing NO production were to maintain some degree of agitation and the keep the pH in the PUREX high, preferably >12. Steel corrosion tests were performed in the presence of low partial pressures of NO{sub 2} and liquid water or water vapor. The NO{sub 2} (from oxidation of NO in the vapor space) ...

1995-05-01

193

Elephant's foot phenomenon in liquid storage tanks  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a method for analyzing the seismic response of a flat bottomed cylindrical liquid storage tank to vertical earthquake excitation. Here, vertical earthquake acceleration is considered to correspond to an increase in the density of a stored liquid. Taking into account the vertical and horizontal earthquake loads, hydrostatic pressure, and considering restrictive moment and shear forces at shell-bottom welded joint, the author has calculated circumferential and longitudinal stresses. These are combined to more accurately approximate the stresses at the base shell course. The calculated result closely conforms to the actual damage, termed ''elephant's foot,'' observed in the fuel storage tanks damaged in the Tangshan earthquake. This result shows that the ''elephant's foot'' phenomenon is not caused by buckling of the ...

1983-01-01

194

Radionuclide air emissions report for the Hanford Site -- calendar year 1997  

Energy Technology Data Exchange (ETDEWEB)

This report documents radionuclide air emission from the Hanford Site in 1997, and the resulting effective dose equivalent to the maximally exposed member of the public, referred to as the MEI. The report has been prepared in accordance with reporting requirements in the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emissions Standards for Hazardous Air Pollutants, Subpart H, National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities. This report has also been prepared in accordance with the reporting requirements of the Washington Administrative Code Chapter 246-247, Radiation Protection-Air Emissions. The effective dose equivalent to the MEI from the Hanford Site`s 1997 point source emissions was 1.2 E-03 mrem (1.2 E-05 mSv), which is well below the 40 CFR 61 Subpart H regulatory limit of 10 mrem/yr. Radon and thoron emissions, exempted from 40 CFR ...

1998-06-17

195

Energy efficient fuzzy based combined variable refrigerant volume and variable air volume air conditioning system for buildings  

Energy Technology Data Exchange (ETDEWEB)

Energy conservative building design has triggered greater interests in developing flexible and sophisticated air conditioning systems capable of achieving enhanced energy-savings potential without sacrificing the desired thermal comfort and indoor air quality (IAQ). This research work greatly aimed at achieving enhanced energy conservation, good thermal comfort and better IAQ for space conditioning with the application of combined variable refrigerant volume (VRV) and variable air volume (VAV) air conditioning (A/C) systems. Experimental investigation on the proposed combined air conditioning system with the application of intelligent fuzzy logic controller was performed for summer and winter climatic conditions to substantiate the energy-savings capability. The proposed system experimentally analyzed under fixed ventilation, demand controlled ventilation (DCV) and combined DCV and economizer cycle (EC) ventilation ...

2010-04-15

196

Environmental Restoration Program quality assurance system requirements for the Hanford Site  

International Nuclear Information System (INIS)

This document defines the quality assurance program requirements for the US Department of Energy, Richland Field Office, Environmental Restoration program at the Hanford Site. This document integrates quality assurance requirements from US Department of Energy Orders, the Hanford Federal Facility Agreement and Consent Order, and applicable industry standards into a single source document for the development of quality assurance programs applicable to the Environmental Restoration program items and activities. This document has been configured into three parts and fifteen criteria to provide user organizations with a workable document that best facilitates line operations. When developing individual user organization quality assurance programs, the document configuration provides each organization with the Flexibility to incorporate only those parts and criteria that are applicable to their individual scope of work as it is associated with the ...

197

Some aspects of concentrated sulphuric acid storage tank corrosion  

Energy Technology Data Exchange (ETDEWEB)

Carbon steel is frequently used to construct concentrated sulphuric acid storage tanks. This paper discussed the corrosion performance of carbon steel tanks and outlined the underlying mechanisms responsible for major corrosion modes. Analyses of hydrogen grooving and dilute acid corrosion failure mechanisms were presented. Recent corrosion-induced leak failures were also discussed. The use of anodic protection and organic coatings as a corrosion control measure was also evaluated. The results of laboratory studies that were conducted to understand corrosion-induced failures showed that carbon steel electrodes exhibited transpassive corrosion at relatively high anodic potentials, while stainless steel electrodes exhibited transpassive corrosion at anodic potentials less than 1 V. It was concluded that corrosion-induced leaks can be prevented by using anodic protection and baked phenolic coating technologies. 23 refs., 9 figs.

2009-07-01

198

Control rod devices  

International Nuclear Information System (INIS)

Purpose: To remove excessive driving pressure applied to an unisolated control rod drive by returning excessive coolant to a condensed water storage tank or to the inlet side of a drive water pump using a coolant flow rate control pipe of a control rod driving hydraulic system. Constitution: Excessive water is returned to a condensed water tank while controlling the excessive coolant by a flow control valve in response to variations in the pressure difference between the reactor pressure and the driving water line when the control rods are isolated using a pipe from the outlet side of the drive water pump to the condensed water storage tank. Thus, the control rod to be isolated is prevented form being dropped. (Sekiya, K.).

199

Radionuclide Air Emissions Report for the Hanford Site Calendar year 1998  

Energy Technology Data Exchange (ETDEWEB)

This report documents radionuclide air emissions from the Hanford Site in I998 and the resulting effective dose equivalent to the maximally exposed individual (MEI) member of the public. The report has been prepared in accordance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (40 CFR SI), Subpart H, ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities,'' and with the Washington Administrative Code Chapter 246-247, Radiation Protection--Air Emissions. The federal regulations in 40 CFR 61, Subpart H; require the measurement and reporting of radionuclides emitted from Department of Energy facilities and the resulting offsite dose from those emissions. A standard of 10 mrem/yr effective dose equivalent (EDE) is imposed on them. The EDE to the MEI due to routine emissions in ...

1999-06-15

200

Reactor cover gas monitoring at the Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400-megawatt (thermal) sodium-cooled reactor designed for irradiation testing of fuels, materials and components for LMRs. It is operated by the Westinghouse Hanford Company for the US Department of Energy on the government-owned Hanford reservation near Richland, Washington. The first 100-day operating cycle began in April 1982 and the eighth operating cycle was completed in July 1986. Argon is used as the cover gas for all sodium systems at the plant. A program for cover gas monitoring has been in effect since the start of sodium fill in 1978. The argon is supplied to the FFTF by a liquid argon Dewar System and used without further purification.

1986-09-24

201

Hanford Environmental Information System (HEIS). Volume 2, Operator`s guide  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the procedures that establish the configuration control processes for the Hanford Environmental Information System (HEIS) software. The procedures also provide the charter and function of the HEIS Configuration Control Board (CCB) for maintaining software. The software configuration control items covered under these procedures include the HEIS software and database structure. The configuration control processes include both administrative and audit functions. The administrative role includes maintaining the overall change schedule, ensuring consistency of proposed changes, negotiating change plan adjustments, setting priorities, and tracking the status of changes. The configuration control process audits to ensure that changes are performed to applicable standards.

1994-01-14

202

Core demonstration lead experiments for irradiation in FFTF  

International Nuclear Information System (INIS)

A major new initiative to develop and irradiate a long-life mixed oxide fuel system in the Fast Flux Test Facility (FFTF) has been implemented by the Westinghouse Hanford Company at the Hanford Engineering Development Lab. for the US Dept. of Energy. The purpose of this new fuel system, called the Core Demonstration Experiment (CDE), is to demonstrate the capability of achieving a 3-yr life in a prototypical heterogeneous reactor environment under prototypical power and temperature conditions. Three Core Demonstration Lead Experiments (CDLEs) will establish the performance characteristics of entire fuel assemblies of wire-wrapped, large diameter, advanced oxide fuel pins with HT-9 stainless steel alloy cladding and wire wrap and an HT-9 duct. Their performance characteristics provided the basis for design, fabrication, and irradiation of the CDE.

1987-06-07

203

Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in England  

Energy Technology Data Exchange (ETDEWEB)

Previous studies have found that classrooms are often inadequately ventilated, with the resultant increased risk of negative impacts on the pupils. This paper describes a series of field measurements that investigated the indoor air quality, thermal comfort and acoustic performance of nine recently built secondary schools in England. The most significant conclusion is that the complex interaction between ventilation, thermal comfort and acoustics presents considerable challenges for designers. The study showed that while the acoustic standards are demanding it was possible to achieve natural ventilation designs that met the criteria for indoor ambient noise levels when external noise levels were not excessive. Most classrooms in the sample met the requirement of limiting the daily average CO{sub 2} concentration to below 1500 ppm but just a few met the need to readily provide 8 l/s per person of fresh air under the easy ...

2009-07-15

204

The effects of ventilation, filtration, and outdoor air on the composition of indoor air at a telephone office building  

Energy Technology Data Exchange (ETDEWEB)

Sensors installed at a telephone office building in Neenah, WI, continuously monitor 24 parameters related to the operation of the building's heating, ventilating, and air conditioning (HVAC) system. This data is stored in a dedicated minicomputer and can be retrieved, in various formats, for subsequent analyses. For more than a year, we have measured indoor and outdoor concentrations of both fine and coarse airborne particles, their chemical constituents, and volatile organic compounds at this same location. Using this data, we have examined the composition of the indoor air as it correlates to the composition of the outdoor air and the various HVAC operating parameters. The steady-state indoor concentrations of the particles, particulate constituents, and organic vapors can be explained in the context of a mass balance model. This model can also be used to calculate the rate at which selected chemicals are generated within the building, as well as to ...

1989-01-01

205

Test-bed for compact ventilation units; Pruefstand fuer Kompaktlueftungsgeraete fuer Komfortlueftung  

Energy Technology Data Exchange (ETDEWEB)

This comprehensive, illustrated report for the Swiss Federal Office of Energy (SFOE) by the University of Applied Sciences in Lucerne, Switzerland takes a look at the testing facility at the university that is used to test compact ventilation systems. These feature heat-recovery and return-air heat-pumps and are used in housing built to low energy-consumption standards such as the Swiss 'Minergie' and 'Minergie-P' standards. The primary goal is a technically comprehensive testing programme for compact ventilation units with heat recovery and heat pumps, which can nevertheless be carried out at reasonable cost. In addition to thermal and flow measurements, acoustic measurements are also carried out. The authors quote that the overall assessment provided can also include service and maintenance, materials used and possible problems with thermal bridges. The test installation is described and the testing ...

2005-12-15

206

Heating and ventilation concept for a better room climate and for energy conservation. Part 1; Heiz- und Lueftungskonzept fuer besseres Raumklima und Energieeinsparung. T. 1  

Energy Technology Data Exchange (ETDEWEB)

Ventilation, cooling and illumination of modern high-rise office buildings with high-quality thermal insulation (average k-value 1.0 W/m12K) and high loads from office machinery (up to 20 W/m12 and beyond) are problematic even for modern facility management systems, with consequences for the building shell, heating system, and window ventilation. [Deutsch] Die Lueftung, Kuehlung und Beleuchtung moderner Buerohochbauten mit extremer Waermedaemmung (mittlerer K-Wert 1,0 W/m{sup 2}K) und hohen Bueromaschinenlasten (bis zu 20 W/m{sup 2} und mehr) verursachen auch heute noch erhebliche Probleme, obwohl die technische Gebaeudeausruestung weiterentwickelt wurde. Dies zeigt sich vor allem bei der Fassadenausbildung der Heizung und Fensterlueftung. (orig.)

1999-11-01

207

Thermal analysis of spent fuel in rehearsal and emergency storage facility (RESF) under station blackout (SBO) in TAPS - 4  

International Nuclear Information System (INIS)

The RESF is utilized for storage of spent fuel under emergency conditions as well as for testing of FM heads. It receives cooling supply from the PHT Pressurizing pumps and after removal of decay heat from the spent fuel it goes to the D2O Storage Tank. The geometry of the RESF system is such that it can not sustain the thermosyphon loop during SBO, due to high frictional forces. To achieve the sustained thermosyphon, modifications in the design were suggested viz., removal of the steam trap and the relief valve above it and replacement by a solenoid valve (SV-16). In the event of SBO, SV-16 will open on 'RESF channel temperature high' signal and connect to FT D2O tank. The tank, being at atmospheric pressure and at lower elevation, will provide higher cooling flow rate through the RESF channel. D2O is periodically removed from the FT D2O tank by operating a Class-II pump intermittently. The analysis ...

2006-11-13

208

The electric fuel zinc-air battery option  

Energy Technology Data Exchange (ETDEWEB)

With specific energy of more than 200 Wh/kg, the Electric Fuel zinc-air battery delivers as much as eight times the energy of lead-acid traction battery, more than twice the energy of the nearest advanced-battery competitor, and as much energy as a tank of gasoline. (author)

1995-12-31

209

Occurrence of fecal indicator bacteria in surface waters and the subsurface aquifer in Key Largo, Florida.  

UK PubMed Central (United Kingdom)

Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available

1995-06-01

210

Measurement of mud level interfaces: A tool for optimization of red mud washing at C.V.G. Bauxilum  

Energy Technology Data Exchange (ETDEWEB)

For the expansion to 2.0 MTPY of the CVG Bauxilum alumina plant, the area of clarification and red mud washing was rearranged from four 2-thickener-5-washer trains to two 1-thickener-7-washer trains. As a result of this modification, the specific mud handling capacity of the existing tanks should be increased by almost 3-times. The time allowed for control actions was then significantly reduced, leading to the need of an on-line level detection system, in order to achieve a better and faster control of the operation. With this scope, it was developed and installed a new continuous mud level detector that gives the measurement of both mud and turbid zone levels in the tanks. The development of the new instrument started with an existing instrument for density measurements which was completely re-engineered in order to obtain the maximum readability in the densities founded along the full range of the tank height. Actually 28 ...

1996-10-01

211

Malaria knowledge and agricultural practices that promote mosquito breeding in two rural farming communities in Oyo State, Nigeria  

UK PubMed Central (United Kingdom)

BackgroundAgricultural practices such as the use of irrigation during rice cultivation, the use of ponds for fish farming and the storage of water in tanks for livestock provide...Full Text Available

212

Investigation of Residue and Coating Stoichiometry on 120-mm Combustible Cartridge Cases.  

Science.gov (United States)

An investigation was conducted to determine the cause of coating residue found in the test gun chambers during qualification firing of 120-mm combustible cartridge case (CCC) ammunition for the MlAl/A2 main battle tank. The CCC is coated with a clear epox...

2000-01-01

213

Foundation of offshore structures  

Energy Technology Data Exchange (ETDEWEB)

This bibliography deals with the foundation of offshore structures like drilling or working platforms (oil and gas exploitation) or offshore tanks. Different kinds of foundations, e.g. pile foundations or shallow foundations, are described. Aspects of soil-structure interaction, engineering geology and soil mechanics are also discussed. (orig.).

1989-08-01

214

FIELD CORROSION TESTS IN REDOX AND PUREX UNDERGROUND WASTE STORAGE TANKS  

Science.gov (United States)

A corrosion-testing program has been initiated in Purex and Redox storage tnnks to obtain corrosion data on carbon steel and three associated materials in neutralized process wastes. (C.W.H.)

1955-06-28

215

BALDWIN COUNTY SEPTIC TANK MAINTENANCE DEMONSTRATION PROJECT MX974480  

Science.gov (United States)

Baldwin County is located on the Gulf of Mexico in Alabama and has a rapidly growing population. Almost 3,000 permits for septic systems are approved annually by by the Baldwin County Health Department. More than 50% of the county's residents rely on septic systems for their d...

216

40 CFR 63.322 - Standards.  

Science.gov (United States)

...Filter gaskets and seatings; (4) Pumps; (5) Solvent tanks and containers; (6) Water separators; (7) Muck cookers; (8) Stills; (9) Exhaust dampers; (10) Diverter valves; and (11) All Filter housings. (l)...

2009-07-01

217

40 CFR 63.321 - Definitions.  

Science.gov (United States)

...limited to, emission control devices, pumps, filters, muck cookers, stills, solvent tanks, solvent containers, water separators...facility that meets the conditions of § 63.320(g). Muck cooker means a device for heating perchloroethylene-laden...

2009-07-01

218

Ventilation as a means of air-conditioning power saving in reinforced concrete telephone-exchange buildings analysis and directions for design  

Energy Technology Data Exchange (ETDEWEB)

The paper presents a computer-aided analysis of the combined use of ventilation and structural heat capacity and insulation as a means of saving air-conditioning power in digital telephone exchanges. It is shown that such savings can be effected by increasing air change with outdoor cool air at night, and when feasible, also in daytime, through the air change unit, in a conventional airconditioning cycle. The total thermal time constant (TTTC) method of calculation used enables the evaluation of daily or seasonal heat-flow balance for a given indoor temperature, considering the tendency of the heat capacity of the building and of envelope components to flatten the fluctuations of this temperature.

1984-12-01

219

On the long term indoor radon concentration measurements the basement of Japanese hospitals  

International Nuclear Information System (INIS)

Long term indoor radon gas measurements using a passive monitor were conducted in the basement rooms of five hospitals, which are built in the Tokyo metropolitan area. The ventilation rate averaged over all hospital was 12.3 air change per hour (ACH). The highest radon concentration was 56.3 Bq/m"3. The value averaged concentration over all hospital and all season was 20 Bq/m"3. But the average of the two hospitals were twice as high as those of three others. Since the total ventilation rate integrated over a day is not different much, the reason of the concentration difference is considered to be the difference in radon emission rate from concrete wall and soil of the each hospital. Though we inquired workers about 'Environmental complaints', it do not show the direct relation between radon and environmental complaints. (author)

220

On the long term indoor radon concentration measurements in the basement HVAC machine room of commercial buildings using a passive monitor method  

International Nuclear Information System (INIS)

Long term indoor radon gas measurements using a passive monitor are now being conducted in the basement HVAC machine rooms of about fifty commercial buildings, which are built in the Tokyo and Nagoya metropolitan area. Ventilation rates are also measured during the monitoring period. The earliest results show that the highest concentration was about twice of the EPA Standards and was obtained at Nagoya in autumn and no clear seasonal change was seen in radon concentration so far, and that the correlation between radon concentration and inverse number of ventilation rate was positive but not high. (orig.). (2 refs., 4 figs., 2 tabs.).

1993-07-04

221

Model-based automation system for demand-based heating and ventilation; Modellgestuetztes Mess- und Automatisierungssystem zur bedarfsgerechten Heizung und Lueftung  

Energy Technology Data Exchange (ETDEWEB)

Better quality of thermal comfort as well as reduced heat energy demand and accordingly CO{sub 2} emission can be achieved by better heating and ventilation strategies in private buildings. The paper deals with a novel model-based measurement and automation system. It describes the implementation of better strategies under given technical circumstances. (orig.) [German] Durch Verbesserung der Heizungs- und Lueftungsstrategien im privaten Lebensbereich kann sowohl Heizenergie eingespart und damit die CO{sub 2}-Emission verringert, als auch die Raumbehaglichkeit verbessert werden. Der Beitrag behandelt ein modellgestuetztes Mess- und Automatisierungssystem, mit dem die Realisierung der verbesserten Strategien unter gegebenen technischen Randbedingungen praktisch erst moeglich wird. (orig.)

2003-04-01

222

Malaspina University-College's green building strategy  

Energy Technology Data Exchange (ETDEWEB)

This brochure describes the strategy employed by the administration of Malaspina University--College in Nanaimo, British Columbia, to implement energy-efficient plans and integrating systems and plans that would allow the institution to consume less energy, fewer resources and improve the health and well-being of its students and staff. An assessment study to identify the most problematic areas, and to develop a prioritizing strategy for their replacement was the first step, followed by rigorous adherence to a 10- year cyclical replacement schedule. The program includes replacement of rooftop ventilation units, installation of high-performance glazing units to replace single-glazed windows, implementation of an Energy Management System to monitor heating, ventilating and air conditioning systems, and a Power Smart New Building Design and Building Improvements Program. The combined cost avoidance associated with these projects is estimated to ...

2000-01-01

223

Indoor climate seminar; Sisaeilmastoseminaari  

Energy Technology Data Exchange (ETDEWEB)

The national energy research programme LVIS-2000: Future Building Services is concerned with the control of energy use and indoor climate in buildings of the future. The projects were presented at a one day seminar arranged by the Laboratory of Heating and Ventilation of the Technical Research Centre in Finland which is coordinating the programme. The presentations at the seminar were: Impurity emission from materials, Building materials and indoor air quality, analysis of organic compounds in indoor air, effect of the return air, effect of the return air on health and comfort, electric heating as an indoor climate factor, calculations of air flows in ventilated rooms, effect of energy saving measures on hospital hygiene, application of modern aerosol measurement technique on indoor climate research.

1989-12-31

224

Fingerprint testing of contaminated ventilation extract filter systems at Sizewell B  

International Nuclear Information System (INIS)

Sizewell B is Nuclear Electric's latest power station, and the Pressurised Water Reactor (PWR) design on which it is based represents a ''first'' for the UK. One of the integral components of the plant is the heating, ventilation and air-conditioning (HVAC) system, which performs a contamination control and gaseous waste management function for the site. During the commissioning of Sizewell B Power Station the extract systems of the HVAC plant underwent a procedure known as ''fingerprinting''. This entailed the characterisation of the facilities provided to test the filtration plant during its lifetime. The assessment of their adequacy was then used to identify necessary modifications and/or to propose the manner in which future in situ performance testing would be carried out. The paper outlines the basic principles and procedure that was used to ''fingerprint'' test systems during the commissioning of Sizewell B. A specific example is presented to demonstrate the ...

225

Handling of sodium for the FFTF  

Science.gov (United States)

Based on the High Temperature Sodium Facility (HTSF) experience and the extensive design efforts for FFTF, procedures are in place for the unloading of the tank cars and for the fill of the FFTF reactor. Special precautions have been taken to provide safe handling and to accommodate contingencies in operation. These contingencies include special protective suits allowing personnel to enter and correct conditions arising from fill operations in the course of moving 7.71 x 10/sup 5/ kg (1.7 x 10/sup 6/ lbs) of sodium from the tank cars into the reactor vessel and its loop system.

1978-06-01

226

Freeze protection valve and system  

Energy Technology Data Exchange (ETDEWEB)

The present invention is a device for a solar heating system having a solar collector, a storage tank connected to the solar collector, a pump for circulating liquid from the tank to the solar collector, a supply of liquid at a temperature above freezing and a connection from the supply of liquid to the solar collector for replacing any liquid lost from said solar collector. The device comprises a sensor for sensing the temperature of liquid in the solar collector, and a valve for bleeding liquid from the solar collector when the sensed temperature falls below a predetermined minimum whereby cool liquid in the solar collector is automatically replaced by liquid at a temperature above freezing.

1985-12-10

227

Effect of tetracycline hydrochloride treatment on the critical thermal maximum of common shiners  

Energy Technology Data Exchange (ETDEWEB)

The transfer of fish from field to laboratory facilities or their propagation in closed or restricted systems frequently results in bacterial infection and ultimately large-scale mortality. In attemps to alleviate this problem, we have added tetracycline hydrochloride to the water prophylactically (pretreating tanks before wild fish were added) and therapeutically (treating tanks after bacterial outbreaks were detected.) In the present study, we examined the effect of tetracyline hydrochloride on the critical thermal maximum (CTM) of the common shiner (Notropis cornutus).

1980-01-01

228

STRESS CORROSION CRACKING SUSCEPTIBILITY OF HIGH LEVEL WASTE TANKS DURING SLUDGE MASS REDUCTION  

Energy Technology Data Exchange (ETDEWEB)

Aluminum is a principal element in alkaline nuclear sludge waste stored in high level waste (HLW) tanks at the Savannah River Site. The mass of sludge in a HLW tank can be reduced through the caustic leaching of aluminum, i.e. converting aluminum oxides (gibbsite) and oxide-hydroxides (boehmite) into soluble hydroxides through reaction with a hot caustic solution. The temperature limits outlined by the chemistry control program for HLW tanks to prevent caustic stress corrosion cracking (CSCC) in concentrated hydroxide solutions will potentially be exceeded during the sludge mass reduction (SMR) campaign. Corrosion testing was performed to determine the potential for CSCC under expected conditions. The experimental test program, developed based upon previous test results and expected conditions during the current SMR campaign, consisted of electrochemical and mechanical testing to determine the susceptibility of ASTM A516 ...

2007-10-18

229

Implementation plan for liquid low-level radioactive waste tank systems for fiscal year 1995 at Oak Ridge National Laboratory under the Federal Facility Agreement, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

This document is the third annual revision of the plans and schedules for implementing the Federal Facility Agreement (FFA) compliance program, originally submitted in 1992 as ES/ER-17&D1, Federal Facility Agreement Plans and Schedules for Liquid Low-Level Radioactive Waste Tank Systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee. This document summarizes the progress that has been made to date in implementing the plans and schedules for meeting the FFA commitments for the Liquid Low-Level Waste (LLLW) System at Oak Ridge National Laboratory (ORNL). Information presented in this document provides a comprehensive summary to facilitate understanding of the FFA compliance program for LLLW tank systems and to present plans and schedules associated with remediation, through the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) process, of LLLW tank systems that have been removed from ...

1995-06-01

230

Design and construction of 125,000kl industrial water tank foundations for Tachibanawan power plant. Deformation in large pile foundations on inclined rockbed and evaluation thereof; Tachibanawan hatsudensho 125,000 kl kogyoyosui tank kiso no sekkei to seko. Keisha kiso ganbanjo no ogata kui kiso no henkei tokusei to hyoka  

Energy Technology Data Exchange (ETDEWEB)

The two tank (125,000kl each) foundations under construction are as large as 85m in diameter, and the north-side tank is to be placed over a sharper slope. The tanks are greatly different in their height from the rockbed since they are to be placed at the same level. For reduction in construction cost and time, a pile foundation design is chosen as the basic concept for foundation construction. After an overall evaluation of stability upon exposure to seismic torsion and of the deformation characteristics of piles and concrete slabs, a total pile foundation design with rock debris replaced with crushed rock is determined to be the design to be adopted. Since the piles to be driven in are greatly different in length, error in the pile supporting force will be too grave under the conventional pile landing control system. Therefore, a high-accuracy pile landing control system is employed, established after a rapid load test in ...

1998-09-05

231

SUPPLEMENTAL COLUMBIA RIVER PROTECTION ACTIVITIES AT THE DEPARTMENT OF ENERGY HANFORD SITE: 2006 TECHNICAL PEER REVIEW  

Energy Technology Data Exchange (ETDEWEB)

Prompted by a $10 million Congressional allocation to identify supplemental actions to protect the Columbia River from groundwater contamination beneath the Hanford Reservation, the U. S. Department of Energy (DOE) Environmental Management (EM) Office of Clean-up Technology identified twenty-three potential technical projects and then down-selected ten of these for further evaluation. An independent expert peer review was conducted for the ten down-selected proposals. The review panel consisted of twenty-three recognized subject matter experts that broadly represented academia, industry, and federal laboratories. Of the initial ten proposals reviewed, one was given unconditional support, six were given conditional support, and three were not supported as proposed. Three additional proposals were then submitted by DOE for review--these proposals were structured, in part, to respond to the initial round of technical peer review comments. Peer reviews of these ...

2006-12-20

232

Return on investment (ROI) proposal preparation guide  

Energy Technology Data Exchange (ETDEWEB)

The ROI Proposal Preparation Guide is a tool to assist Hanford waste generators in preparing ROI proposal forms for submittal to Department of Energy, Richland Operations Office (DOE/RL) for funding. The guide describes the requirements for submitting an ROI proposal and provides examples of completed ROI forms. The intent is to assist waste generators in identifying projects that meet the criteria, provide information necessary to complete the ROI forms, and submit a proposal that is eligible to receive funding.

1998-10-09

233

FFTF: an outstanding engineering achievement  

International Nuclear Information System (INIS)

The Fast Flux Test Facility on the federal reservation at Hanford, Washington, has become a bright star in the universe of nuclear science and engineering technologies. The entire FFTF enterprise is now a success story, and this is particularly significant in these days when good news about nuclear power is scarce. The reactor, its testing capabilities and associated test facilities are described.

234

FDH radiological design review guidelines  

Energy Technology Data Exchange (ETDEWEB)

These guidelines discuss in more detail the radiological design review process used by the Project Hanford Management Contractors as described in HNF-PRO-1622, Radiological Design Review Process. They are intended to supplement the procedure by providing background information on the design review process and providing a ready source of information to design reviewers. The guidelines are not intended to contain all the information in the procedure, but at points, in order to maintain continuity, they contain some of the same information.

1998-09-29

235

A qualitative evaluation of radionuclide concentrations in Hanford Site Wildlife, 1983 through 1992  

Energy Technology Data Exchange (ETDEWEB)

Environmental monitoring has been conducted at the U.S. Department of Energy`s (DOE`s) Hanford Site in southeastern Washington State since 1945. Fish and wildlife have been monitored since 1945, however, a major emphasis on mammals did not occur until the 1970s. This report focuses on the 10-year period from 1983 through 1992. The objectives of this report are to evaluate {sup 90}Sr and {sup 137}Cs concentrations in Site wildlife populations and, when possible, evaluate trends in concentrations over this period of time. No distinct trends in radionuclide concentrations were apparent in most species sampled. Many measurements were at or below the analytical limit of detection. This evaluation found that concentrations of {sup 90}Sr in rabbit and deer bone were elevated in animals collected from areas adjacent to industrialized areas. Similarly, radionuclide concentrations in duck muscle from waterfowl collected at B Pond were elevated with {sup 137}Cs when compared ...

1994-10-01

236

Radionuclide Distribution Coefficients for Sediments Collected from Borehole 299-E17-21: Final Report for Subtask 1a  

Energy Technology Data Exchange (ETDEWEB)

Over 360 distribution coefficients (KJ for cesium, iodine, selenium, Strontium, technetium, and uranium were measured in fiscal year 1998 using 20 sediments collected fkom borehole 299-El 7-21 on the Hanford Site as part of the Immobilized Low-Activity Waste-Performance Assessment (ILAW-PA). Additionally, the pH and cation-exchange capacity (a measure of the total quantity of cations that a sediment can adsorb) of these sediment samples were measured. The sediment samples originated from the Hanford formation (informal name). Statistical analyses, using Student's t-test and correlation were conducted with the measured values. There were no significant differences between layers 1 and 2 for the selenium, strontium, technetium, and uranium & values (statistics could not be applied to evaluate layer 3 &values). Significant differences between the cesium and iodine&values for layem 1 and 2 were observed. However, these ...

1998-10-14

237

Ozone hazards incurred in #gamma#-plant operation  

International Nuclear Information System (INIS)

The irradiation of air produces some toxic gases such as ozone, nitric oxide, nitrogen dioxide, nitrogen trioxide, nitrogen tetroxide, nitric anhydride and nitrous oxide. Of these gases, ozone is the most important because of its toxicity and may be produced in such quantities as to constitute a health hazard within the irradiation room. The toxicity, and explosive characteristics of ozone and quantitative aspects of ozone production are discussed and ventilation requirements considered. (U.K.).

238

Natural ventilation of a room through a large external opening: calculation using a CFD code; Ventilation naturelle d`un local par une grande ouverture exterieure: calcul a l`aide d`un code de champ  

Energy Technology Data Exchange (ETDEWEB)

This paper is dedicated to the numerical study of natural ventilation in a room through a large external opening using the CFD code Fluent. Bidimensional numerical simulations are performed for wind speeds up to 5.55 m-s{sup -1} (20 km-h{sup -1}). We propose a two-step solution procedure with grid refinement. When combined with appropriate thermal boundary conditions, this technique appears very efficient at limiting local convergence problems. Through an analysis of the flow pattern in the cavity, we qualitatively explain those results and define a critical Archimedes number. Calculated air change rates are compared to values deduced from empirical correlations of the literature. Agreement is in general poor, which can be explained by the differences between the conditions of our simulations and those of the experiments that lead to those correlations. However, from our simulations, we derived very clear correlations between the air change coefficient and the ...

1998-02-01

239

Environmental effects and energy efficiency in building design - a green building approach. Pt. 1. Energy efficiency techniques  

Energy Technology Data Exchange (ETDEWEB)

A research report describes the energy efficiency techniques to be employed in designing a building which is ``green``. Topics covered include building fabric performance, ventilation and infiltration, passive solar design, heating systems and controls, hot and cold water provision, lighting and electrical appliances. (UK)

1993-12-31

240

Development of High-Efficiency Low-Lift Vapor Compression System - Final Report  

Energy Technology Data Exchange (ETDEWEB)

PNNL, with cofunding from the Bonneville Power Administration (BPA) and Building Technologies Program, conducted a research and development activity targeted at addressing the energy efficiency goals targeted in the BPA roadmap. PNNL investigated an integrated heating, ventilation and air conditioning (HVAC) system option referred to as the low-lift cooling system that potentially offers an increase in HVAC energy performance relative to ASHRAE Standard 90.1-2004.

2010-03-31

241

Atlas of room air flow; Raumstroemungsatlas  

Energy Technology Data Exchange (ETDEWEB)

Within the framework of the IEA project Annex 20 - Airflow patters within buildings , an airflow data base was built up as a prototype. It enables airflow profiles, comfort and interior air quality to be studied without having to carry out a 1:1 experiment or having to run an expensive simulation code. The data base contains a number of pre-calculated room airflow profiles with their associated depictions of air quality and risks of drafts for given premises and for different ventilation systems. figs., tabs., refs.

1994-12-31

242

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

243

Method and device for the graduated charging of finely-particulate solid substances into an industrial furnace. Verfahren und Vorrichtung zum dosierten Einfuehren feinkoerniger Feststoffe in einen Industrieofen  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a method for the graduated introduction of finely-particulate and especially pulverously-particulate solid substance, in particular coal dust, from a pressurised proportioning tank containing a supply of solid matter into an industrial furnace with several supply points, in particular a shaft furnace such as a blast furnace or a cupola furnace, the solid matter being conveyed to the individual supply points in a flow of carrier gas heavily charged with solid matter, through a separate transport line for each supply point, the carrier gas being conveyed to the lower end section of the proportioning tank in a current which causes a local loosening in the lower section of the supply of solid matter, with the transport lines opening into the loosened area, whilst the proportioning tank that contains the solid matter is weighed continuously, the actual weight of the proportioning tank ...

1987-09-09

244

Isothermal refuelling of natural gas vehicles with condensed natural gas CNG; Isotherme Betankung von Erdgasfahrzeugen mit komprimiertem Erdgas CNG  

Energy Technology Data Exchange (ETDEWEB)

CNG vehicles suffer from an uncontrolled temperature rise of the gas inside the tank during the filling process and heat exchange with the environment leads to variable filling levels. A partly filled tank reduces the range of CNG vehicles and works as a impediment to the spreading of environmentaly more friendly CNG vehicles. The increase of the pressure inside the tank combined with a prolongation of the filling time beyond three minutes can reduce the deficit of the filling process. For economic reasons the time required for refuelling should be as short as possible without the need to operate the filling station with a critical pressure. To meet this target the current technique requires further improvement. (orig.) [Deutsch] Die betriebliche Praxis bei Tankvorgaengen von Erdgasfahrzeugen zeigt, dass waehrend des Tankvorganges die Temperatur des getankten Erdgases im Fahrzeugtank ansteigt. Waehrend und nach Beendigung ...

1998-07-01

245

Commissioning and operation of new liquid poison injection based shut down system in TAPP-3 and 4  

International Nuclear Information System (INIS)

Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable modifications and the ...

2006-11-13

246

Two-dimensional natural convective heat transfer analysis in an open cavity and its application to KMRR  

International Nuclear Information System (INIS)

Natural convection flow is established in KMRR (Korea Multi-Purpose Research Reactor) reflector tank at the loss of reflector circulator. To simulate the reflector tank natural convection flow with high temperatures at the inner shell and bottom plate due to nuclear heating, experimental and numerical studies in an open cavity with 'L' type heated wall made by the combination of a vertical and horizontal plate were performed. It was confirmed through these studies that the heat transfer rates were highest at the lower region of the vertical plate and the inlet region of horizontal plate and comparatively high at the middle portion of both plates. The heat transfer rate distribution of this trend shows a desirable trend for the effective natural convection cooling of KMRR reflector tank. It was also confirmed that the average Nusselts numbers at the 'L' type heated wall were lower than those obtained from the existing ...

1991-10-26

247

Large temperature differential thermal storage system. Its design and evaluation  

Energy Technology Data Exchange (ETDEWEB)

A large temperature differential (10K) thermal storage system in a small (4400 m{sup 2}) 8-storey office building is discussed and the monitoring results are analyzed in comparison with computer simulations. Requirements were a comfortable indoor environment and system cost effectiveness. Out of four potential system concepts, the Large Temperature Differential System was chosen. It comprises a flat-type thermal stratification heat storage tank in the under floor pit of the building as the heat source for a variable flow heat pump chiller. The heat sink is a set of serially connected air handling and fan coil units. The tank`s capacity is sized for one day operation and is made as large as possible to shift the electricity demand to night time. To avoid a large size and high cost, the water temperature differential was enlarged. The role of Tokyo Electric Power Company (TEPCO) was to develop the chiller and its control system. It is concluded ...

1996-07-01

248

Kinetics of absorption of trace iodine vapor in aqueous solution of sodium hydroxide, (2)  

International Nuclear Information System (INIS)

A liquid column was used for the experiments reported in Part 1. However, it only gives the observation of the effect of fast reaction because the liquid flow was controlled to uniform laminar flow and the contact is limited to short time of around 10 ms. In practical absorbing operation, turbulence is involved in liquid flow, and the residence time for contact is long. Hence, the absorption of trace iodine in the purified air has been experimented by using a constant interface area type stirred absorption tank. Prior to the experiment, the characteristics of the absorption tank was investigated by conducting pure carbon dioxide absorption test with purified water. It gave the conclusion that the tank was sufficiently usable for fundamental researches. In short contact time absorption, the iodine dissolved and absorbed in liquid phase is affected by reaction of hypoiodous acid and poly-iodide ion formation due to hydrolysis ...

1978-01-01

249

Batch test equilibration studies examining the removal of Cs, Sr, and Tc from supernatants from ORNL underground storage tanks by selected ion exchangers  

Energy Technology Data Exchange (ETDEWEB)

Bench-scale batch equilibration tests have been conducted with supernatants from two underground tanks at the Melton Valley Storage Tank (MVST) Facility at Oak Ridge National Laboratory (ORNL) to determine the effectiveness of selected ion exchangers in removing cesium, strontium, and technetium. Seven sorbents were evaluated for cesium removal, nine for strontium removal, and four for technetium removal. The results indicate that granular potassium cobalt hexacyanoferrate was the most effective of the exchangers evaluated for removing cesium from the supernatants. The powdered forms of sodium titanate (NaTiO) and cystalline silicotitanate (CST) were superior in removing the strontium; however, for the sorbents of suitable particle size for column use, titanium monohydrogen phosphate (TiHP {phi}), sodium titanate/polyacrylonitrile (NaTiO-PAN), and titanium monohydrogen phosphate/polyacrylonitrile (TiP-PAN) gave the best results and were about ...

1995-06-01

250

Waste sampling and characterization facility (WSCF)  

Energy Technology Data Exchange (ETDEWEB)

The Waste Sampling and Characterization Facility (WSCF) complex consists of the main structure (WSCF) and four support structures located in the 600 Area of the Hanford site east of the 200 West area and south of the Hanford Meterology Station. WSCF is to be used for low level sample analysis, less than 2 mRem. The Laboratory features state-of-the-art analytical and low level radiological counting equipment for gaseous, soil, and liquid sample analysis. In particular, this facility is to be used to perform Resource Conservation and Recovery Act (RCRA) of 1976 and Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) of 1980 sample analysis in accordance with U.S. Environmental Protection Agency Protocols, room air and stack monitoring sample analysis, waste water treatment process support, and contractor laboratory quality assurance checks. The samples to be analyzed contain very low concentrations of radioisotopes. The ...

1994-10-01

251

Use of Hanford waste water ponds by waterfowl  

International Nuclear Information System (INIS)

Census and environmental surveillance information on waterfowl that use the Hanford Site 200 Area waste water ponds are described and evaluated. Physical features of the ponds are discussed in relation to their use and suitability for waterfowl. Seasonal distributions observed for the years 1971 through 1974 indicate that the highest use by waterfowl occurs during the spring and fall migratory periods. Base population estimates are 300 to 400 resident waterfowl with a few tens of pairs nesting during the summer. Environmental surveillance data on "1"3"7Cs in muscle tissue are presented for the years 1971 through 1977. Comparisons are made between Columbia River and waste water pond waterfowl, between waterfowl groups, and among ponds. Waterfowl collected from ponds frequently have easily detected levels of "1"3"7Cs in muscle tissue. However, those waterfowl collected from the Columbia River seldom show a "1"3"7Cs level above that expected from worldwide fallout. ...

1979-05-01

252

The 300 Area Integrated Field Research Challenge Quality Assurance Project Plan  

Energy Technology Data Exchange (ETDEWEB)

Pacific Northwest National Laboratory and a group of expert collaborators are using the U.S. Department of Energy Hanford Site 300 Area uranium plume within the footprint of the 300-FF-5 groundwater operable unit as a site for an Integrated Field-Scale Subsurface Research Challenge (IFRC). The IFRC is entitled Multi-Scale Mass Transfer Processes Controlling Natural Attenuation and Engineered Remediation: An IFRC Focused on the Hanford Site 300 Area Uranium Plume Project. The theme is investigation of multi-scale mass transfer processes. A series of forefront science questions on mass transfer are posed for research that relate to the effect of spatial heterogeneities; the importance of scale; coupled interactions between biogeochemical, hydrologic, and mass transfer processes; and measurements/approaches needed to characterize and model a mass transfer-dominated system. This Quality Assurance Project Plan provides the quality assurance ...

2009-04-29

253

Status report on the development of a three-dimensional conceptual model for the Hanford Site unconfined aquifer system  

Energy Technology Data Exchange (ETDEWEB)

This report presents the status of development of a three-dimensional conceptual model for the unconfined aquifer system at Hanford. A conceptual model is needed to support development of a realistic three-dimensional numerical model for predicting ground-water flow and the transport of contaminants. The report focuses on developing a hydrogeologic framework, assessing available hydraulic property data, describing flow-system boundaries, and evaluating areal recharge and leakage. Geologic descriptions of samples obtained during well drilling were used to prepare cross sections that correlate relatively continuous layers. The layers were defined based on textural differences that are expected to reflect differences in hydraulic properties. Assigning hydraulic properties to the layers is a critical part of the conceptual model. Available hydraulic property data for the study area were compiled and were correlated with the geologic layers where possible. Flow-system ...

1992-11-01

254

Sludge stabilization at the Plutonium Finishing Plant, Hanford Site, Richland, Washington  

Energy Technology Data Exchange (ETDEWEB)

This Environmental Assessment evaluates the proposed action to operate two laboratory-size muffle furnaces in glovebox HC-21C, located in the Plutonium Finishing Plant (PFP), Hanford Site, Richland, Washington. The muffle furnaces would be used to stabilize chemically reactive sludges that contain approximately 25 kilograms (55 pounds) of plutonium by heating to approximately 500 to 1000{degrees}C (900 to 1800{degrees}F). The resulting stable powder, mostly plutonium oxide with impurities, would be stored in the PFP vaults. The presence of chemically reactive plutonium-bearing sludges in the process gloveboxes poses a risk to workers from radiation exposure and limits the availability of storage space for future plant cleanup. Therefore, there is a need to stabilize the material into a form suitable for long-term storage. This proposed action would be an interim action, which would take place prior to completion of an Environmental Impact Statement for the PFP ...

1994-10-01

255

SOW for Services Provided by the Waste Sampling Characterization Facility (WSCF) for the Environmental Compliance Program during CY 2000  

Energy Technology Data Exchange (ETDEWEB)

This document defines analytical services the Waste Sampling and Characterization Facility (WSCF) shall provide the Environmental Compliance Program (ECP) throughout calendar year (CY) 2000. Two organizations within ECP are responsible for monitoring liquid and gaseous effluents and the environment immediately around facilities that contain or may contain radioactive and hazardous materials. Monitoring & Reporting (M&R), of Fluor Hanford Environmental Services, is responsible for effluent monitoring data, and Environmental Monitoring & Investigations (EMI), of Waste Management Technical Services, Inc., for near-facility environmental monitoring data. These organizations serve numerous projects, some of which are managed by other companies such as CH2M HILL and Bechtel Hanford, Inc. Monitoring data are collected and evaluated to determine their state of compliance with applicable federal and state regulations and permits, and ...

2000-06-01

256

Registration of Hanford Site Class V underground injection wells  

Energy Technology Data Exchange (ETDEWEB)

This document was requested by the Washington State Department of Ecology. Based on the State Underground Injection Control Program, as described in the Washington Administrative Code, French drains and reverse wells are being registered as Class V wells. Information on out-of-service French drains, out-of-service reverse wells, and out-of-service cribs that are deeper than their largest surface dimension is also provided. The data for this submittal were taken from the Waste Information Database System (WIDS) and the Hanford Environmental Compliance Record (HECR) database. The current definition used in WIDS for an ''inactive facility'' is one that either no longer receives waste or plans to in the future. The facilities listed in WIDS as inactive have all been listed as ''out-of-service.'' Information concerning the deactivation method for a facility is included when such information is ...

1988-05-01

257

Hazard analysis for 300 Area N Reactor Fuel Fabrication and Storage Facilty  

Energy Technology Data Exchange (ETDEWEB)

This hazard analysis (HA) has been prepared for the 300 Area N Reactor Fuel Fabrication and Storage Facility (Facility), in compliance with the requirements of Westinghouse Hanford Company (Westinghouse Hanford) controlled manual WHC-CM-4-46, Nonreactor Facility Safety Analysis Manual, and to the direction of WHC-IP-0690, Safety Analysis and Regulation Desk Instructions, (WHC 1992). An HA identifies potentially hazardous conditions in a facility and the associated potential accident scenarios. Unlike the Facility hazard classification documented in WHC-SD-NR-HC-004, Hazard Classification for 300 Area N Reactor Fuel Fabrication and Storage Facility, (Huang 1993), which is based on unmitigated consequences, credit is taken in an HA for administrative controls or engineered safety features planned or in place. The HA is the foundation for the accident analysis. The significant event scenarios identified by this HA will be further evaluated in a ...

1994-01-25

258

Fuels and materials testing capabilities in Fast Flux Test Facility  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test assembly (FOTA), closed loop in-reactor assembly (CLIRA), and other special fuel assemblies. An interim examination and maintenance cell (FFTF/IEM ...

1989-07-01

259

Fuels and materials testing capabilities in Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) reactor, which started operating in 1982, is a 400 MWt sodium-cooled fast neutron reactor located in Hanford, Washington State, and operated by Westinghouse Hanford Co. under contract with U.S. Department of Energy. The reactor has a wide variety of functions for irradiation tests and special tests, and its major purpose is the irradiation of fuel and material for liquid metal reactor, nuclear reactor and space reactor projects. The review first describes major technical specifications and current conditions of the FFTF reactor. Then the plan for irradiation testing is outlined focusing on general features, fuel pin/assembly irradiation tests, and absorber irradiation tests. Assemblies for special tests include the material open test assembly (MOTA), fuel open test assembly (FOTA), closed loop in-reactor assembly (CLIRA), and other special fuel assemblies. An interim examination and maintenance cell (FFTF/IEM ...

260

Fiscal year 1996 U.S. Department of Energy, Richland Operations Office Site summary baseline  

International Nuclear Information System (INIS)

The technical baseline is a hierarchical description of the Hanford Site cleanup mission. This technical baseline does not address the science, technology, or economic transition missions. It begins with a definition of the existing conditions at the Hanford Site, provides a description of the end product or mission accomplishments at completion, presents a statement of the major requirements and constraints that must be observed during the performance of the mission, and provides a statement of the top-level strategic approach to accomplish the mission. Mission-level interfaces are also described. This information is further defined hierarchically in increasing levels of detail. This definition is composed of the following major elements: functions that are key task descriptions; requirements that are the measurable standards to which the functions must be performed; architectures which are specific engineering solutions or systems that ...

2009-06-01

261

FFTF [Fast Flux Test Facility] fuel handling experience (1979--1986)  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF)is a 400 MW (th) sodium-cooled fast flux test reactor located on the Hanford Site in southeastern Washington State. The FFTF is operated by the Westinghouse Hanford Company for the United States Department of Energy. The FFTF is a three loop plant designed primarily for the purpose of testing full-scale core components in an environment prototypic of future liquid metal reactors. The plant design emphasizes features to enhance this test capability, especially in the area of the core, reactor vessel, and refueling system. Eight special test positions are provided in the vessel head to permit contact instrumented experiments to be installed and irradiated. These test positions effectively divide the core into three sectors. Each sector requires its own In-Vessel Handling Machine (IVHM) to access all the core positions. Since the core and the in-vessel refueling components are submerged under sodium, all handling ...

1987-09-01

262

FFTF [Fast Flux Test Facility] cesium trap design, installation, and operating experience  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400-MWt, sodium-cooled reactor located on the Hanford Site near Richland, Washington, USA. The FFTF is owned by the U.S. Department of Energy and is operated by the Westinghouse Hanford Company. The FFTF was designed to test fuels and materials for use in liquid metal reactors. Since initial operation in 1982, anticipated breaches of experimental fuel pins have released fission products, including cesium, into the primary sodium. Because of its high volatility, cesium vaporizes into the cover gas space, where it condenses on components and equipment and is transported into the cover gas outlet. Because of the long half-life of "1"3"7Cs, these deposits result in long-term, local radiation levels that make contact maintenance difficult. Thus, a cesium trap was installed in FFTF to reduce the cesium level in the sodium. The trap could also permit a Run Beyond Cladding Breach (RBCB) program without ...

1988-10-17

263

FFTF [Fast Flux Test Facility] Integrated Leak Rate Test Computer System  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford Site. The FFTF is the only reactor of this type designed and operated with the intent of meeting the licensing requirements of the Nuclear Regulatory Commission (NRC). Unique characteristics of the FFTF that present special challenges related to leak rate testing include thin wall containment vessel construction, cover gas systems that penetrate containment, and a low-pressure design basis accident. The successful completion in 1986 of the third FFTF Integrated Leak Rate Test (ILRT) five days ahead of schedule and 10% under budget was a major achievement for the Westinghouse Hanford Company. The success of this operational safety test was due in large part to a special local area network (LAN) of three IBM PC/XT computers that monitored the sensor data, calculated the containment vessel leak rate, and displayed test results. The multiple computer ...

264

Environmental Restoration Remedial Action quality assurance requirements document  

International Nuclear Information System (INIS)

This document defines the quality assurance requirements for the US Department of Energy-Richland Operations Office Environmental Restoration Remedial Action program at the Hanford Site. The Environmental Restoration Remedial Action program implements significant commitments made by the US Department of Energy in the Hanford Federal Facility Agreement and Consent Order entered into with the Washington State Department of Ecology and the US Environmental Protection Agency. This document combines quality assurance requirements from various source documents into one set of requirements for use by the US Department of Energy-Richland Operations Office and other Environmental Restoration Remedial Action program participants. This document will serve as the basis for developing Quality Assurance Program Plans and implementing procedures by the participants. The requirements of this document will be applied to activities affecting quality, using a ...

265

An aerial radiological survey of the Hanford Site and surrounding area, Richland, Washington  

International Nuclear Information System (INIS)

An aerial radiological survey was conducted over the Department of Energy's Hanford Site near Richland, Washington, during the period 5 July through 26 August 1988. The survey was expanded, and additional flights were conducted to the east of the site and along the banks of the Columbia River down to McNary Dam near Umatilla. The survey was flown at altitude of 61 meters (200 feet) by a helicopter containing 17 liters (eight 2 in. x 4 in. x 16 in.) of sodium iodide detectors. Gamma ray data were collected over the survey area by flying north-south lines spaced 122 meters (400 feet) apart. The processed data indicated that detected radioisotopes and their associated gamma ray exposure rates were generally consistent with those expected from normal background emitters and man-made fission/activation products resulting from activities at the site. External exposure rates were generally 10 microroentgens per hour (#mu#R/h) with some operating areas over 1000 #mu#R/h. ...

1990-09-16

266

Vacuum leak problem in low energy of pelletron  

International Nuclear Information System (INIS)

During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)

267

The MiniBooNE detector technical design report  

Energy Technology Data Exchange (ETDEWEB)

The MiniBooNE experiment [1] is motivated by the LSND observation, [2] which has been interpreted as {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, and by the atmospheric neutrino deficit, [3,4,5] which may be ascribed to {nu}{sub {mu}} oscillations into another type of neutrino. MiniBooNE is a single-detector experiment designed to: obtain {approx} 1000 {nu}{sub {mu}} {yields} {nu}{sub e} events if the LSND signal is due to {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, establishing the oscillation signal at the > 5{sigma} level as shown in Fig. 1.1; extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations significantly beyond what has been studied previously if no signal is observed; search for {nu}{sub {mu}} disappearance to address the atmospheric neutrino deficit with a signal that is a suppression of the rate of {nu}{sub {mu}}C {yields} {mu}N events from the expected 600,000 per year; measure the oscillation parameters as shown in Fig. 1.2 if ...

2003-04-18

268

Subcritical measurements with a cylindrical tank of Pu-U nitrate  

Energy Technology Data Exchange (ETDEWEB)

This series of measurements with a mixed Pu-U nitrate solution (280 g Pu/liter, 180 g U/liter) in a 35.54-cm-diam cylindrical tank provides a wide variety of experimental data for subcritical configurations that can be used to verify calculational methods and nuclear data. The Pu contained 7.85 wt% {sup 240}Pu and the uranium was natural uranium. The measurements performed were: inverse count rate, prompt neutron decay constants, inverse kinetics, and frequency analysis by the {sup 252}Cf source driven method. These data are presented in sufficient detail that the results of the experiments can be calculated directly. For purposes of extrapolating to the delayed critical height the ratio of spectral densities was linear with height and thus provided the best estimate of critical height.

1997-04-01

269

Solids distribution in tall tanks  

British Library Electronic Table of Contents (United Kingdom)

Abstract Uniformly distributing slurry solids in -tall- (-2:1 aspect ratio) process vessels is a significant challenge in the chemical industry. This work determined the performance of various multi-tier agitation systems in uniformly distributing a settling solid throughout water in a -tall- laboratory vessel. It used a 0.445-m ID Plexiglas tank, with a slurry height of 0.889-m, to determine how solids distribution changes with solids loading (wt.%), impeller speed, and impeller type. Some impeller types uniformly distributed the solids even before energy input exceeded 1.00-W/kg. Significantly higher energy improved solids distribution little because flow within the vessel eventually became choked.

2011-01-01

270

Rocky Mountain Arsenal, Basin F liquid storage tank spill, draft risk assessment  

Energy Technology Data Exchange (ETDEWEB)

The scope of this RA is limited to the evaluation of potential human health risks associated with a failure event of a tank containing Basin F liquid. Section 1.0 contains an introduction to the health risk assessment. Section 2.0 describes the site history, location, and land use. Section 3.0 provides a brief description of exposure pathways and potention receptors. Section 4.0 describes the sources of data used and identifies chemicals of concern. Section 5.0 discusses the toxicity of concern. Section 6.0 explains the methods used for calculation of carcinogenic risks and the noncarcinogenic hazard indexes. Section 7.0 describes uncertainties inherent in the current methodology used to determine potential human health risks. Section 8.0 presents a summary of results and conclusions. Section 9.0 includes the references cited.

1993-04-01

271

Radon concentration measurements at water reservoirs  

International Nuclear Information System (INIS)

Ground water is treated in the Czech Republic so that small water tanks are built above each water source to serve the primary ground water treatment; water so pretreated is then concentrated in large basins for subsequent treatment. Some water tanks where the first contact of the ground water with air takes place were selected as sites predisposed to radon accumulation. The examination was carried out near the town of Jihlava, where the bedrock contains slightly elevated radium concentrations. The average radon concentrations lay within the region of 2-4 kBq/m"3; the instantaneous values, however, exhibited appreciable periodical variations during the day. The relatively high radon concentrations will not pose a marked hazard for the personnel because the employees only reside at the sites in question for 10 to 15 minutes within 2 days, not for the whole working day

1998-09-09

272

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

273

Liquid radioactive waste discharges from B plant to cribs  

Energy Technology Data Exchange (ETDEWEB)

This engineering report compiles information on types and quantities of liquid waste discharged from B-Plant directly to cribs, ditches, reverse wells, etc., that are associated with B-Plant. Waste discharges to these cribs via overflow form 241-B, 241-BX, and 241-BY tank farms, and waste discharged to these cribs from sources other than B-Plant are discussed.Discharges from B-Plant to other cribs, unplanned releases, or waste remaining in tanks are not included in the report. Waste stream composition information is used to predict quantities of individual chemicals sent to cribs. This provides an accurate mass balance of waste streams from B-Plant to these cribs. These predictions are compared with known crib inventories as a verification of the process.

1996-05-29

274

Fuel cell hybrid taxi life cycle analysis  

British Library Electronic Table of Contents (United Kingdom)

A small fleet of classic London Taxis (Black cabs) equipped with hydrogen fuel cell power systems is being prepared for demonstration during the 2012 London Olympics. This paper presents a Life Cycle Analysis for these vehicles in terms of energy consumption and CO2 emissions, focusing on the impacts of alternative vehicle technologies for the Taxi, combining the fuel life cycle (Tank-to-Wheel and Well-to-Tank) and vehicle materials Cradle-to-Grave. An internal combustion engine diesel taxi was used as the reference vehicle for the currently available technology. This is compared to battery and fuel cell vehicle configurations. Accordingly, the following energy pathways are compared: diesel, electricity and hydrogen (derived from natural gas steam reforming). Full Life Cycle Analysis, usin...

2011-01-01

275

Device for energy-saving heating of fuel in the fuel supply for an internal combustion engine  

Energy Technology Data Exchange (ETDEWEB)

The invention concerns a device for the energy-saving heating of fuel in the supply pipe to an internal combustion engine to regain energy from the fuel itself, particularly but not exclusively for a Diesel engine. A part of the quantity of heat added to the fuel between the tank and the injection nozzles is given up by excess fuel not to the tank, but to the fuel lifted upstream of the injection pump. The device is characterised by the fact that it has a heat exchanger, which absorbs heat from the fuel at the level of the injection pump or upstream of it, and takes this to the fuel above the injection pump. The heat exchanger is preferably mounted upstream of a filter and close to it. A bridging pipe, which may be integrated in the heat exchanger, permits the heat exchanger to be short-circuited depending on the fuel temperature.

1981-02-10

276

Design on SDS2 on-line poison concentration monitoring in CANDU  

Energy Technology Data Exchange (ETDEWEB)

At the reference plant (Wolsung unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsung unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low. 8 refs., 1 fig. (author).

1996-10-01

277

Concentration of Melton Valley Storage Tank surrogates with a wiped film evaporator  

Energy Technology Data Exchange (ETDEWEB)

This report describes experiments to determine whether a wiped film evaporator (WFE) might be used to concentrate low-level liquid radioactive waste (LLLW). Solutions used in these studies were surrogates that contain no radionuclides. The compositions of the surrogates were based on one of Oak Ridge National Laboratory`s (ORNL`s) Melton Valley Storage Tanks (MVSTs). It was found that a WFE could be used to concentrate LLLW to varying degrees by manipulating various parameters. The parameters studied were rotor speed, process fluid feed temperature and feed rate, and evaporator temperature. Product consistency varied from an unsaturated liquid to a dry powder. Volume reductions up to 68% were achieved. System decontamination factors were consistently in the range of 10{sup 4}.

1994-08-01

278

A novel domestic electric water heater model for a multi-objective demand side management program  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a novel domestic hot water heater model to be used in a multi-objective demand side management program. The model incorporates both the thermal losses and the water usage to determine the temperature of the water in the tank. Water heater loads are extracted from household load data and then used to determine the household water usage patterns. The benefits of the model are: (1) the on/off state of the water heater and temperature of the water in the tank can be accurately predicted, and (2) it enables the development of water usage profiles so that users can be classified based on usage behaviour. As a result, the amount of ancillary services and peak shaving that can be achieved are accurately predictable and can be maximized without adversely affecting users. (author)

2010-12-15

279

/sup 252/Cf-source-driven neutron noise measurements of subcriticality for a slab tank containing aqueous Pu-U nitrate  

Energy Technology Data Exchange (ETDEWEB)

In order to study nuclear criticality safety related to the development of fast breeder technology, /sup 252/Cf-source-driven neutron noise analysis measurements were performed with a Pu-U nitrate solution in a slab tank of various heights and thickness varying 11.43 cm to 19.05 cm. The results and conclusions of these experiments are (1) a capability to measure the subcriticality of a multiplying system of slab geometry to a k/sub eff/ as low as 0.7 was demonstrated, (2) calculated neutron multiplication factors agreed with those from the experiments within approx.0.02, and (3) the applicability of the method for plutonium solution systems was demonstrated. This paper describes measurements in which the height of the slab was varied for a fixed thickness and the thickness varied for a fixed height, which are the first applications of this measurement method to slab geometry.

1987-08-01

280

Material-not-categorized-as-waste survey for 1992  

Energy Technology Data Exchange (ETDEWEB)

In October 1992, the US Department of Energy, Richland Field Office (RL) requested that Westinghouse Hanford Company (WHC) respond to a letter from EM-331 asking for completion of a survey of items in storage but not categorized as waste (Roberts 1992). The letter contained an attachment with instructions on how to fill out the attached form and what to exclude from the survey (Appendix A). This report is a summary of the information from the response issued to RL. This report primarily is for use in estimating future waste volumes that may have been overlooked because of the nature of their classification as material not categorized as waste (MNCAW) (i.e., not yet declared Waste).

1993-07-01

281

Maintenance implementation plan for T Plant. Revision 2  

Energy Technology Data Exchange (ETDEWEB)

This document is a Maintenance Implementation Plan (MIP) for the T Plant Facility complex located in the 200 West Area of the Hanford Reservation in Washington state. This plan has been developed to provide a disciplined approach to maintenance functions and to describe how the T Plant facility will implement and comply with the regulations according to US DOE order 4330.4B, entitled Maintenance Management Program, Chapter 2.0 {open_quotes}Nuclear Facilities{close_quotes}. Physical structures, systems, processes, as well as all associated equipment specifically assigned to these groups are included in the MIP.

1995-05-01

282

FFTF operating experience 1982-1984  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 MWt sodium-cooled fast reactor operated by Westinghouse Hanford Company for the US Department of Energy to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor programme. Early in 1982, the FFTF began its first 100 day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94 per cent in the most recent irradiation cycle. The authors describe the results achieved in the first three cycles of operation and carrying through to the fourth reactor cycle which began in January 1984. (author).

283

Application of the GEM shutdown device to the FFTF reactor  

Energy Technology Data Exchange (ETDEWEB)

A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.

1986-01-01

284

Application of the GEM shutdown device to the FFTF reactor  

International Nuclear Information System (INIS)

A novel device called the gas expansion model (GEM) is being developed at the Hanford Engineering Development Laboratory for testing in the 400-MW(th) fast flux test facility (FFTF) reactor. Incorporation of the GEM into liquid-metal reactor designs is intended to measurably contribute to the achievement of inherent safety, by allowing the reactor to passively shut down even in the extremely remote (hypothetical) event of an unprotected (no scram) loss-of-flow accident. The purpose of this paper is to describe the GEM and present predictive analyses of the effectiveness of the device during unprotected loss-of-flow experiments in the FFTF.

1986-11-16

285

Wind tunnel tests of biodegradable fugitive dust suppressants being considered to reduce soil erosion by wind at radioactive waste construction sites  

International Nuclear Information System (INIS)

Wind tunnel tests were performed of three fugitive dust control agents derived from potato and sugar beet products. These materials are being considered for use as dust suppressants to reduce the potential for transport of radioactive materials by wind from radioactive waste construction and remediation sites. Soil and dust control agent type, solution concentrations, application quantities, aging (or drying) conditions, surface disturbance, and wind and saltating sand eolian erosive stresses were selected and controlled to simulate application and exposure of excavated soil surfaces in the field. A description of the tests, results, conclusions, and recommendations are presented in this report. The results of this study indicate that all three dust control agents can protect exposed soil surfaces from extreme eolian stresses. It is also clear that the interaction and performance of each agent with various soil types may differ dramatically. Thus, soils similar to that received from ML ...

1993-01-01

286

Maintenance implementation plan for solid waste management  

Energy Technology Data Exchange (ETDEWEB)

This Maintenance Implementation Plan (MIP)was developed for implementation of the U.S. Department of Energy (DOE) Order 4330.4A, A Maintenance Implementation Program (DOE 1990) which has been replaced by 4330.4B (DOE 1994) at the Hanford Site SWM complex. It addresses maintenance functions associated with SWM, which includes the field operational group and the facilities operational group. An assessment of the existing maintenance programs for SWM was performed, and the results of this assessment were evaluated to determine corrective actions required to bring Solid Waste Maintenance into compliance with the order. The objective of this MIP is to provide baseline information for the control and execution of SWM Maintenance activities relative to the requirements of Order 4330.4B, Chapter II. (Nuclear Facilities) It also describes actions that are planned to achieve compliance. Section 2.0 of this MIP summarizes the mission, history, and future plans of SWM. Section ...

1996-06-27

287

Evaluation of Phase II glass formulations for vitrification of Hanford Site low-level waste  

Energy Technology Data Exchange (ETDEWEB)

A vendor glass formulation study was carried out at Pacific Northwest Laboratory (PNL), supporting the Phase I and Phase II melter vendor testing activities for Westinghouse Hanford Company. This study is built upon the LLW glass optimization effort that will be described in a separate report. For Phase I vendor melter testing, six glass formulations were developed at PNL and additional were developed by Phase I vendors. All the doses were characterized in terms of viscosity and chemical durability by the 7-day Product Consistency Test. Twelve Phase II glass formulations (see Tables 3.5 and 3.6) were developed to accommodate 2.5 wt% P{sub 2}O{sub 5} and 1.0 wt% S0{sub 3} without significant processing problems. These levels of P{sub 2}O{sub 5} and SO{sub 3} are expected to be the highest possible concentrations from Hanford Site LLW streams at 25 wt% waste loading in glass. The Phase H compositions formulated were 6 to 23 times more durable ...

1996-03-01

288

Analysis and decision document in support of acquisition of steam supply for the Hanford 200 Area  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) is now evaluating its facility requirements in support of its cleanup mission at Hanford. One of the early findings is that the 200-Area steam plants, constructed in 1943, will not meet future space heating and process needs. Because the 200 Area will serve as the primary area for waste treatment and long-term storage, a reliable steam supply is a critical element of Hanford operations. This Analysis and Decision Document (ADD) is a preliminary review of the steam supply options available to the DOE. The ADD contains a comprehensive evaluation of the two major acquisition options: line-term versus privatization. It addresses the life-cycle costs associated with each alternative, as well as factors such as contracting requirements and the impact of market, safety, security, and regulatory issues. Specifically, this ADD documents current and future steam requirements for the 200 Area, describes alternatives ...

1992-02-01

289

The use of noninvasive mechanical ventilation in COPD with severe hypercapnic acidosis  

British Library Electronic Table of Contents (United Kingdom)

SummaryStudy Objectives: To compare the effect of noninvasive mechanical ventilation (NIV) in severely acidotic with mildly acidotic patients with acute hypercapnic chronic obstructive lung disease (COPD).Design: Comparison of NIV in consecutively enrolled patients with acute hypercapnic COPD with mild (pH 7.25-7.35) or severe (pHPaCO2, duration of NIV treatment, length of stay in hospital and survival.Results (meadian (IQR)): Twenty-nine patients had 36 episodes of acute hypercapnic respiratory failure: Seventeen with pHPaCO2 improve (12 (6-34) vs 12 (4-28)h, respectively, Formula Not Shown ), with similar duration of NIV treatment (60 (35-96) vs 68 (36-48)h, respectively, Formula Not Shown ) and hospital length of stay (8 (7-18) vs 9 (5-17) days, respectively, Formula Not Shown ). Overal...

2007-01-01

290

The indoor environment and advanced ventilation systems; Binnenmilieu steeds afhankelijker van geavanceerde ventilatie  

Energy Technology Data Exchange (ETDEWEB)

A lower energy efficiency standard for buildings (EPC) can have a negative impact on thermal comfort and indoor air quality. Cooperation and integrated design are preconditions for a correct use, installation and maintenance of heating and ventilation systems in buildings. [Dutch] Er komt steeds meer kritiek op de wijze waarop in ons land woningen en gebouwen worden gebouwd. Op dit moment is het vooral woonhuisventilatie waar veel om te doen is. Van beleidsmakers tot aannemers en van Consumentenbond tot gezondheidsdiensten; iedereen vraagt zich af of we met vergaande isolatie onze woningen en gebouwen nog wel leefbaar houden. In dit artikel wordt een pleidooi gehouden voor onderlinge samenwerking en integraal ontwerp als randvoorwaarden voor een goede toepassing, installatie en onderhoud van verwarmings- en ventilatiesystemen in gebouwen.

2006-09-15

291

Radon-mitigation in buildings  

International Nuclear Information System (INIS)

From the indoor radon problem arises a great challenge for the radiation protection of the population. The soil can be considered as the only source for high radon concentrations in buildings. The contribution of common building materials to high indoor concentrations with a range of 30 Bq/m"3 is negligible low. Therefore building materials for radon mitigation should be judged by their tightness against diffusive radon and not by their radon exhalation rate. Also isolation materials for mitigation should be radon tight. The radon diffusion coefficient describes the physical processes in relatively homogeneous samples. The diffusion coefficient D and the diffusion length R are very exactly determined by a self engineered measuring method. The range of D reaches from D = (0.0005 to 2.35) . 10"-"6 m"2/s for building materials and from D = (0.07 to < 10"-"6) . 10"-"6 m"2/s for isolation materials. Applicable mitigation measures like increased ventilation rates, ...

292

Airflow modelling and fire smoke propagation in the new Ecole Polytechnique building  

Energy Technology Data Exchange (ETDEWEB)

A study was conducted to predict indoor ventilation, smoke movement and fire propagation in a new building currently under construction at the Ecole Polytechnique de Montreal. It was conducted in response to concerns regarding the impact that air quality, in normal operation conditions, and smoke concentration, in the event of a fire, may have on occupants of a building. A detailed three-dimensional model of the new building was constructed using the NURBS-based modeler, Rhino. Simulations of fire propagation and airflow ventilation were performed in different areas of the building. The flow pattern data was analyzed using the computational fluid dynamics (CFD) program called FLUENT. It predicted air flow conditions and estimated the mean age of air (MAA) in the room. Real-world geometries, such as diffuser inlets, have a significant impact on overall fluid flow behaviour and are necessary for this type of analysis. The fire simulation was ...

2005-07-01

293

Air conditioning system planning for Kanagawa Science Park (KSP) building. Kanagawa Science Park (KSP) no kuki chowa setsubi  

Energy Technology Data Exchange (ETDEWEB)

Urban type R D (research and development) facilities have research institute functions which are not desirable to coexist in a city as compared with suburban R D facilities. Therefore careful consideration must be given to environmental protection. KSP is the first large scale urban type R D facility in Japan. The planning and construction have been made with the theme of realization of flexibility in architecture and mechanical planning as well as realization of environmental integrity. To achieve the target so-called technical slit is built at the center of the building to provide a void space for securing natural ventilation. It is effective for provision of internal mechanical spaces without spoiling urban View air exhaust from laboratories natural ventilation for underground parking lots and decrease of damage by strong wind on the ground level. Standards are established and organization is formed for environmental administration to ...

1991-12-05

294

Renovation of air-conditioning at La Defense; Renovation de la climatisation a La Defense  

Energy Technology Data Exchange (ETDEWEB)

Twenty years after its building, the tertiary sector of La Defense district near Paris has been rehabilitated. The main reason is not only the age and wear of materials but the heating costs, the fire protection regulations, the search for a better air quality and air renewing with less dusts, smells and noise and a controlled moisture. This paper describes first the original installation of the Monge CB 6 office building and then the renovated installation: the central hot and cold air-treatment plant, the variable flow ventilation system, the air extraction and supply system threw the roofs and the pressure and thermal regulation of the installation. (J.S.)

1997-05-01

295

Radiant heating and cooling, displacement ventilation with heat recovery and storm water cooling: An environmentally responsible HVAC system  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.

1998-12-31

296

Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)  

Energy Technology Data Exchange (ETDEWEB)

Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).

1993-01-01

297

Natural gas use in Saskatchewan hog industry  

Energy Technology Data Exchange (ETDEWEB)

A study was conducted to examine the energy consumption in existing and new hog farming facilities and to analyse the potential for increased natural gas use in the Saskatchewan hog industry. Existing heating/cooling, ventilation and feed mill equipment choices offer possibilities for running on electricity, natural gas or propane. Energy costs are lowest when natural gas is used. To put the study in context, an overview of the Saskatchewan hog industry was provided. The potential increase in natural gas use in hog production by year 2005 was estimated. 10 refs., 6 tabs., 8 figs.

1996-11-01

298

Indoor radon pollution: Control and mitigation. June 1978-December 1989 (Citations from the NTIS data base). Report for June 1978-December 1989  

International Nuclear Information System (INIS)

This bibliography contains citations concerning the control and mitigation of radon pollution in homes and commercial buildings. Citations cover radon transport studies in buildings and soils, remedial action proposals on contaminated buildings, soil venting, building ventilation, sealants, filtration systems, water degassing, reduction of radon sources in building materials, and evaluation of existing radon mitigation programs including their cost effectiveness. Analysis and detection of radon and radon toxicity are covered in separate published bibliographies. (Contains 129 citations fully indexed and including a title list.).

299

Heating-cooling ceilings and cold beams; Plafonds chauffants-rafraichissants et poutres froides  

Energy Technology Data Exchange (ETDEWEB)

The aim of this document is to make a state-of-the-art of the techniques of heating-cooling ceilings and cold beams. These systems offer many advantages: they generate a high quality thermal comfort, they are energy efficient, and offer important room saving, particularly interesting in the case of building renovation. The document comprises 5 parts dealing with: 1 - the heating-cooling ceilings; 2 - the cold beams; 3 - the elements necessary for the dimensioning (building-system interactions, ventilation, temperature regulation and safety systems); 4 - dimensioning method; 5 - design, realization and operation: the rules to follow. (J.S.)

2004-07-01

300

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions, Second Edition  

Energy Technology Data Exchange (ETDEWEB)

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.

2007-05-01

301

Energy Savings Modeling and Inspection Guidelines for Commercial Building Federal Tax Deductions  

Energy Technology Data Exchange (ETDEWEB)

This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.

2007-02-01

302

Anesthetic considerations for nontransplant procedures in lung transplant patients  

British Library Electronic Table of Contents (United Kingdom)

Lung transplantation has become an accepted option for many patients with end-stage pulmonary diseases. Anesthesia and surgery following lung transplantation may be required for various diseases that may affect both systemic organs and the transplanted graft. When a patient with a lung transplant undergoes surgery, there is the potential for interference with lung function, depending on the type of intervention and its anatomical site. Accurate preoperative evaluation, an understanding of the physiology of the transplanted lung, proper airway instrumentation, individualized management of intraoperative ventilation, and fluid balance are essential for a positive perioperative outcome.

2011-01-01

303

A study on the reduction of indoor radon contamination  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the present study is to find ways to reduce the quantity of indoor radon contamination. The study was done from July, 2005 until December, 2005. It was found out that the easiest and most effective way to do that is to open the windows as often as possible and let the indoor air flow outside. When it is not possible to ventilate a room, the indoor radon contamination quantity can reduced by providing activated charcoal in the room. It has been proved that activated charcoal can absorb the room in the air. We need more activated charcoal in proportion to the size of the room. A further research is needed to investigate the amount of activated charcoal that will work most effectively.

2006-06-15

304

High air quality and low energy consumption. Performance of hybrid ventilation with CO2-sensors; Hoge luchtkwaliteit en lage energiebesparing. Goede prestaties van hybride ventilatie met CO2-sensoren  

Energy Technology Data Exchange (ETDEWEB)

The school building complex Waterland in The Hague, Netherlands, was built with a hybrid ventilation system. The indoor environment and energy consumption were monitored for one year. Air quality and thermal comfort are of a high quality and the consumption of energy for heating is circa 35% lower than normal. The Waterland project was one of eight demonstration projects, carried out within the framework of the ECBS-Annex 35: Hybrid ventilation in New and retrofitted Office Buildings. ECBS stands for the IEA-program Energy Conservation in Buildings and Community Systems. [Dutch] In ECBCs-annex 35 (ECBS staat voor het IEA-programma Energy Conservation in Buildings and Community Systems) is uitgebreid onderzoek gedaan naar hybride ventilatiesystemen in kantoren en scholen. Dit project heeft geleid tot acht internationale voorbeeldprojecten, waarvan scholencomplex Waterland te Den Haag er een van is. Het scholencomplex is in 2003 opgeleverd met ...

2005-11-01

305

Determination of radon-222 concentration in inside environments of the Instituto de Engenharia Nuclear, Brazil; Determinacao da concentracao de radonio-222 nos ambientes internos das instalacoes do Instituto de Engenharia Nuclear  

Energy Technology Data Exchange (ETDEWEB)

The gotten concentrations of radon-222 in the installations of the IEN had been determined using the active and passive methods. The active method consisted on the use of the alpha spectrometry with a portable equipment Tracerlab Instruments WLM- Plus. In the determination for the passive method, one used detectors of nuclear strokes of type LEXAN. The raised values had been gotten in the wastes deposit and its annexes, room of the press and laboratory of wastes handling. It was observed, in this sector, an instantaneous measure of alpha spectrometry, concentrations around 1000 Bq.m-3, which had over all to the function of storage, the sector, a great volume of natural radioactive materials, especially of radium-226. This determination was carried through in an extreme situation of ventilation zero, where the gates had been kept closed during the execution of the same one. It was observed, however, a considerable fall, with values ten times inferior, after to ...

2000-07-01

306

An experimental study of the ventilation performance of cold-air distribution systems  

Energy Technology Data Exchange (ETDEWEB)

The ventilation performance of cold-air distribution systems was investigated in a full-scale test room for three different designs of ceiling-mounted diffusers: a large square radial, a small square radial, and two linear diffusers. The supply air temperature was 38 F (3.3 C). Tests were conducted with internal heat loads and with and without furnishings. The local mean ages of air, air diffusion effectiveness, and contaminant-removal efficiency were measured using tracer gas techniques to assess the performance of the ventilation system in maintaining adequate air quality conditions in the occupied region. Air velocities and temperatures were also measured in the occupied region to calculate the air diffusion performance index (ADPI). It was found that the cold-air distribution system provided satisfactory air quality and thermal comfort conditions to the occupied region of the room. It was also found that internal furnishings (partitions, ...

1994-12-31

307

A desiccant dehumidifier for electric vehicle heating  

Energy Technology Data Exchange (ETDEWEB)

Vehicle heating requires a substantial amount of energy. Engines in conventional cars produce enough waste heat to provide comfort heating and defogging/defrosting, even under very extreme conditions. Electric vehicles (EVs), however, generate little waste heat. Using battery energy for heating may consume a substantial fraction of the energy storage capacity, reducing the vehicle range, which is one of the most important parameters in determining EV acceptability. Water vapor generated by the vehicle passengers is in large part responsible for the high heating loads existing in vehicles. In cold climates, the generation of water vapor inside the car may result in water condensation on the windows, diminishing visibility. Two strategies are commonly used to avoid condensation on windows: windows are kept warm, and a large amount of ambient air is introduced in the vehicle. Either strategy results in a substantial heating load. These strategies are often used in combination, and a ...

1996-09-01

308

Performance Assessment Monitoring Plan for the Hanford Site Low-Level Burial Grounds  

Energy Technology Data Exchange (ETDEWEB)

The U.S. Department of Energy Order 435.1, Radioactive Waste Management, requires a disposal authorization statement authorizing operation (or continued operation) for low-level waste disposal facilities. In fulfillment of these requirements, a disposal authorization statement was issued on October 25, 1999, authorizing the Hanford Site to transfer, receive, possess, and dispose of low-level radioactive waste at the 200 East Area burial grounds and the 200 West Area burial grounds. One of the conditions is that monitoring plans for the 200 East Area and 200 West Area low-level burial grounds be written and approved by the Richland Operations Office. As a result of a record of decision for the Hanford Site Solid Waste Program and acceptance of the Hanford Site Solid Waste Environmental Impact Statement, the use of the low-level burial ground (LLBG) as a disposal facility for low-level and mixed low-level wastes has been ...

2006-03-30

309

Recent process developments at the SOMAIRE uranium mill  

International Nuclear Information System (INIS)

This paper reviews the mill flowsheet applied at the SOMAIR (Societe des Mines de l'Air) uranium mill in Niger. It focuses on the yellow cake quality improvements achieved by molybdenum and zirconium elimination through double yellow cake precipitation in tanks at first stage and through size/density control in a fluidized bed precipitator at second stage. Water saving aspects in the plant are also presented. (author)

2000-09-09

310

Projected radionuclide inventories of DWPF glass from current waste at time of production  

Energy Technology Data Exchange (ETDEWEB)

The Waste Acceptance Preliminary Specifications (WAPS) require that the DWPF estimate the inventory of long-lived radionuclides present in the waste glass, and report the values in the Waste Form Qualification Report. In this report, conservative (biased high) estimates of the radionuclide inventory of glass produced from waste currently in the Tank Farm are provided. In most cases, these calculated values compare favorably with actual data. In those cases where the agreement is not good, the values reported here are conservative.

1993-02-04

311

Project quality assurance plant: Sodium storage facility, project F-031  

International Nuclear Information System (INIS)

The Sodium Storage Facility Project Quality Assurance Plan delineates the quality assurance requirements for construction of a new facility, modifications to the sodium storage tanks, and tie-ins to the FFTF Plant. This plan provides direction for the types of verifications necessary to satisfy the functional requirements within the project scope and applicable regulatory requirements determined in the Project Functional Design Criteria (FDC), WHC-SD-FF-FDC-009.

312

Project W-314 Polyurea Special Protective Coating (SPC) Test Plan Chemical Compatibility and Physical Characteristics Testing  

Energy Technology Data Exchange (ETDEWEB)

This Test Plan outlines the testing to be done on the Special Protective Coating (SPC) Polyurea which includes: Tank Waste Compatibility, Decontamination Factor Testing, and Adhesion Strength Testing after a sample has been exposed to Radiation.

2001-01-15

313

Integrated vermi-pisciculture - an alternative option for recycling of solid municipal waste in rural India  

Energy Technology Data Exchange (ETDEWEB)

Vermicomposts as a biofertilizer can be a great option for pond manuring as they never cause any long term harm to the soil like chemical fertilizer. In this study vegetable and horticulture waste was used as an important media for vermiculture. Three separate cemented tanks (6 m{sup 3} each) were used in the system as control tank, vermicompost fertilized tank and inorganic fertilizer manured tank. Monoculture of fish was carried out with cat fish, Clarias batrachus. The produced earthworms were used as fish feed. Regular monitoring of water parameter was conducted in three different ponds. Specifically, the algal biomass variation was quite helpful in analysing the behavior of the ponds. NPK value of soil samples was analyzed intermittently to know the eutrophication level. Despite the hot summer temperature in northern part of India, which is not ideal for fish growth, we have recorded an encouraging ...

2004-05-01

314

Information systems definition architecture  

Energy Technology Data Exchange (ETDEWEB)

The Tank Waste Remediation System (TWRS) Information Systems Definition architecture evaluated information Management (IM) processes in several key organizations. The intent of the study is to identify improvements in TWRS IM processes that will enable better support to the TWRS mission, and accommodate changes in TWRS business environment. The ultimate goals of the study are to reduce IM costs, Manage the configuration of TWRS IM elements, and improve IM-related process performance.

1996-06-20

315

High level waste storage tanks 242-A evaporator S/RID phase II assessment report  

Energy Technology Data Exchange (ETDEWEB)

This document, the Standards/Requirements Identification Document (S/RID) Phase 2 Assessment Report for the subject facility, represents the results of a Performance Assessment to determine whether procedures containing S/RID requirements are fully implemented by field personnel in the field. It contains a summary report and three attachments; an assessment schedule, performance objectives, and assessments for selected functional areas.

1996-09-27

316

High level waste storage tank farms/242-A evaporator standards/requirements identification document phase 1 assessment report  

Energy Technology Data Exchange (ETDEWEB)

This document, the Standards/Requirements Identification Document (S/RID) Phase I Assessment Report for the subject facility, represents the results of an Administrative Assessment to determine whether S/RID requirements are fully addressed by existing policies, plans or procedures. It contains; compliance status, remedial actions, and an implementing manuals report linking S/RID elements to requirement source to implementing manual and section.

1996-09-30

317

Fluidic pumps  

International Nuclear Information System (INIS)

A fluidic pump comprises a two-diode pump having a first displacement vessel, a third diode connected to receive output from the two-diode pump through a delivery line and discharge to an outlet, and a second displacement vessel connected to the delivery line. There is a feed tank at a greater height than the two-diode pump, and a drive unit for alternately pressurising and venting the first and second displacement vessels. The drive pressure required to operate the pump can be of the order of half that for a single stage 2-diode pump. (author).

1988-05-19

318

Experimental verification of caustic-side solvent extraction for removal of cesium from tank waste.  

Energy Technology Data Exchange (ETDEWEB)

The objectives of this report are: to demonstrate complete CSSX process flowsheet (proof of concept)--decontamination factor {ge} 40,000, and concentration factor {approx}15; Scientific and technical issues evaluated--stage efficiency, temperature control, hydraulic performance, long time (multi-day) operation, short-term shutdown, effect of solids, and recovery from Cs moving through strip section.

2001-09-21

319

Determination of reactor kinetic parameters in a two-core reactor  

Energy Technology Data Exchange (ETDEWEB)

The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.

1982-01-01

320

B Plant treatment, storage, and disposal (TSD) units inspection plan  

Energy Technology Data Exchange (ETDEWEB)

This inspection plan is written to meet the requirements of WAC 173-303 for operations of a TSD facility. Owners/operators of TSD facilities are required to inspection their facility and active waste management units to prevent and/or detect malfunctions, discharges and other conditions potentially hazardous to human health and the environment. A written plan detailing these inspection efforts must be maintained at the facility in accordance with Washington Administrative Code (WAC), Chapter 173-303, ``Dangerous Waste Regulations`` (WAC 173-303), a written inspection plan is required for the operation of a treatment, storage and disposal (TSD) facility and individual TSD units. B Plant is a permitted TSD facility currently operating under interim status with an approved Part A Permit. Various operational systems and locations within or under the control of B Plant have been permitted for waste management activities. Included are the following TSD units: Cell 4 Container Storage Area; B ...

1996-04-26

321

Feasibility study for use of the natural convection shutdown heat removal test facility (NSTF) for VHTR water-cooled RCCS shutdown  

International Nuclear Information System (INIS)

In summary, a scaling analysis of a water-cooled Reactor Cavity Cooling System (RCCS) system was performed based on generic information on the RCCS design of PBMR. The analysis demonstrates that the water-cooled RCCS can be simulated at the ANL NSTF facility at a prototypic scale in the lateral direction and about half scale in the vertical direction. Because, by necessity, the scaling is based on a number of approximations, and because no analytical information is available on the performance of a reference water-cooled RCCS, the scaling analysis presented here needs to be 'validated' by analysis of the steady state and transient performance of a reference water-cooled RCCS design. The analysis of the RCCS performance by CFD and system codes presents a number of challenges including: strong 3-D effects in the cavity and the RCCS tubes; simulation of turbulence in flows characterized by natural circulation, high Rayleigh numbers and low Reynolds numbers; validity of heat transfer ...

322

National Ignition Facility Incorporates P2/E2 in Aqueous Parts Cleaning of Optics Hardware  

Energy Technology Data Exchange (ETDEWEB)

When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, weight, geometry, surface finish and ...

2001-07-27

323

MENDING THE IN SITU MANIPULATION BARRIER  

Energy Technology Data Exchange (ETDEWEB)

In early 2004, the U.S. Department of Energy (DOE) Richland and Fluor Hanford requested technical assistance from the DOE Headquarters EM-23 Technical Assistance Program to provide a team of technical experts to develop recommendations for mending the In Situ Redox Manipulation (ISRM) Barrier in the 100-D Area of the Hanford Site in Washington State. To accommodate this request, EM-23 provided support to convene a group of technical experts from industry, a national laboratory, and a DOE site to participate in a 2 1/2-day workshop with the objective of identifying and recommending options to enhance the performance of the 100-D Area reactive barrier and of a planned extension to the northeast. This report provides written documentation of the team's findings and recommendations. In 1995, a plume of dissolved hexavalent chromium [Cr(VI)], which resulted from operation of the D/DR Reactors at the Hanford site, was ...

2006-02-06

324

Laser application in the fabrication of gas-tagged capsules. A leak detection system  

Energy Technology Data Exchange (ETDEWEB)

Encapsulation of a unique isotopic blend of krypton and xenon gas employs a special application of laser technology. The encapsulated gas is then used as the primary medium for detection and identification of failed nuclear fuel rods. The use of gas tagging as a means of detecting and identifying failed nuclear fuel rods has been successfully demonstrated and used by the Argonne National Laboratory, Experimental Breeder Reactor (EBR-2) Project, and the Westinghouse Hanford Company (WHC), Fast Flux Test Facility (FFTF) Fast Breeder Reactor Program. The Power Reactor and Nuclear Fuel Development Corporation (PNC) of Japan has selected this leak detection system for use in their MONJU Prototype Reactor fuel assemblies. The MONJU reactor is almost identical in design to the highly successful FFTF reactor, which is currently in standby status.

1993-12-01

325

Five years operating experience at the Fast Flux Test Facility  

Energy Technology Data Exchange (ETDEWEB)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.

1987-04-01

326

Five years operating experience at the Fast Flux Test Facility  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mw(t), loop-type, sodium-cooled, fast neutron reactor. It is operated by the Westinghouse Hanford Company for the United States Department of Energy at Richland, Washington. The FFTF is a multipurpose test reactor used to irradiate fuels and materials for programs such as Liquid Metal Reactor (LMR) research, fusion research, space power systems, isotope production and international research. FFTF is also used for testing concepts to be used in Advanced Reactors which will be designed to maximize passive safety features and not require complex shutdown systems to assure safe shutdown and heat removal. The FFTF also provides experience in the operation and maintenance of a reactor having prototypic components and systems typical of large LMR (LMFBR) power plants. The 5 year operational performance of the FFTF reactor is discussed in this report. 6 refs., 10 figs., 2 tabs.

1987-09-13

327

Fabrication of core demonstration experiments for irradiation in the FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

A major new initiative to develop and irradiate a long-lived, mixed-oxide (MOX) fuel system in the Fast Flux Test Facility (FFTF) has been implemented by Westinghouse Hanford Company for the U.S. Department of Energy. The purpose of this new fuel system, called the core demonstration experiment (CDE), is to demonstrate the capability of achieving a 3-yr life in a prototypical, heterogeneous reactor environment under prototypical power and temperature conditions. Ten fuel and six blanket CDEs are establishing the performance characteristics of entire fuel assemblies of wire-wrapped, large-diameter, annular-pellet, advanced MOX fuel pins with the tempered martensitic HT-9 alloy cladding and end caps, HT-9 wire wrap, and an HT-9 duct in a heterogeneous array with the blanket assemblies. The CDE performance characteristics are confirming the basis for design, fabrication, and irradiation of the CDE.

1990-06-10

328

Fabrication of core demonstration experiments for irradiation in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

A major initiative to develop and irradiate a long-life, mixed-oxide fuel system in the Fast Flux Test Facility (FFTF) has been implemented by Westinghouse Hanford Company for the US Department of Energy. The FFTF, shown in Figures 1 and 2, is a 400 megawatt thermal, fast liquid metal reactor that tests liquid metal, space and fusion fuels and materials. The new fuel system, called the Core Demonstration Experiment (CDE) demonstrates the capability of achieving a three- to four-year life in a prototypic heterogeneous reactor environment under prototypic power and temperature conditions. This fuel system will greatly increase fuel performance and lifetime from the current standard FFTF driver fuel. New design features, fabrication development, CDE assembly fabrication, and irradiation status have been described.

1990-06-10

329

FFTF operating experience, 1982-1984  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a 400 Mwt sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory, Richland, Washington, to conduct fuels and materials testing in support of the US Liquid Metal Fast Breeder Reactor (LMFBR) program. Startup and initial power testing included a comprehensive series of nonnuclear and nuclear tests to verify the thermal, hydraulic, and neutronic characteristics of the plant. A specially designed series of natural circulation tests were then performed to demonstrate the inherent safety features of the plant. Early in 1982, the FFTF began its first 100-day irradiation cycle. Since that time the plant has operated very well, achieving a cycle capacity factor of 94% in the most recent irradiation cycle. Seventy-five specific test assemblies and 25,000 individual fuel pins have been irradiated, some in excess of 80 MWd/Kg.

1984-04-09

330

FFTF [Fast Flux Test Facility] management  

International Nuclear Information System (INIS)

Fuel Management at the Fast Flux Test Facility (FFTF) involves more than just the usual ex-core and in-core management of standard fuel and non-fuel components between storage locations and within the core since it is primarily an irradiation test facility. This mission involves testing an ever increasing variety of fueled and non-fueled experiments, each having unique requirements on the reactor core as well as having its own individual impact on the reload design. This paper describes the fuel management process used by the Westinghouse Hanford Company Core Engineering group that has led to the successful reload design of nine operating cycles and the irradiation of over 120 tests.

1987-09-13

331

Environmental education work force pipeline strategic plan  

Energy Technology Data Exchange (ETDEWEB)

This document describes an educational program designed to provide a pool of highly qualified administrative, technical, and managerial graduates that are familiar with the Hanford Site and business operations. The program is designed to provide work experience and mentoring to a culturally diverse student base which enhances affirmative employment goals. Short-term and long-term objectives of the program are outlined in the report, and current objectives are discussed in more detail. Goals to be completed by the year 2003 are aimed at defining the criteria necessary to establish partnerships between schools, community organizations, and human resources departments. Actions to be implemented includes providing instructors and equipment, enhancing skills of local teachers, and establishing collaboration with human resources organizations. Long-term goals of the program are to ensure a constant supply of qualified, trained workers to support industry missions. 6 ...

1992-11-01

332

Environmental costs and benefits case study: nuclear power plant. Quantification and economic valuation of selected environmental impacts/effects. Final report  

International Nuclear Information System (INIS)

This case study is an application, to a nuclear power plant, of the methodology for quantifying environmental costs and benefits, contained in the regional energy plan, adopted in April, 1983, by the Northwest Power Planning Council, pursuant to Public Law 96-501.The study is based on plant number 2 of the Washington Public Power Supply System (WNP-2), currently nearing completion on the Hanford Nuclear Reservation in eastern Washington State. This report describes and documents efforts to quantify and estimate monetary values for the following seven areas of environmental effects: radiation/health effects, socioeconomic/infrastructure effects, consumptive use of water, psychological/health effects (fear/stress), waste management, nuclear power plant accidents, and decommissioning costs. 103 references.

333

Development of the FFTF and N-fuel rotary shear fuel segmentation  

International Nuclear Information System (INIS)

Development testing has been conducted by Rockwell Hanford Operations (Rockwell) with simulated Fast Flux Test Facility (FFTF) Reactor fuel and unirradiated N-Reactor fuel, to identify the various problems associated with rotary shearing these fuels. This report discusses the results of tests segmenting FFTF and N-Reactor fuels using electrically driven slow-speed rotary shredders. From these tests, it has been determined that slow-speed rotary shredding of both fuels can be accomplished. Final equipment arrangements and operating parameters have been established for definitive design of the FFTF Rotary Shear. Development testing is continuing on the N-fuel rotary shear. However, it has been established that two-stage shearing is necessary and the outer N-fuel elements pose few problems, while the smaller inner elements have created numerous problems, which are being addressed.

334

Combining innovative technology demonstrations with dense nonaqueous phase liquids cleanup  

Energy Technology Data Exchange (ETDEWEB)

Radioactively contaminated acidic aqueous wastes and organic liquids were discharged to the soil column at three disposal sites within the 200 West Area of the Hanford Site, Washington. As a result, a portion of the underlying groundwater is contaminated with carbon tetrachloride several orders of magnitude above the maximum contaminant level accepted for a drinking water supply. Treatability testing and cleanup actions have been initiated to remove the contamination from both the unsaturated soils to minimize further groundwater contamination and the groundwater itself. To expedite cleanup, innovative technologies for (1) drilling, (2) site characterization, (3) monitoring, (4) well field development, and (5) contaminant treatment are being demonstrated and subsequently used where possible to improve the rates and cost savings associated with the removal of carbon tetrachloride from the soils and groundwater.

1993-05-01

335

The Biogas/Biofertilizer Business Handbook. Third Edition. Appropriate Technologies for Development. Reprint R-48.  

Science.gov (United States)

This book describes one approach to building and operating biogas systems. The biogas systems include raw material preparation, digesters, separate gas storage tanks, use of the gas to run engines, and the use of the sludge as fertilizer. Chapters included are: (1) "Introduction"; (2) "Biogas Systems are Small Factories"; (3) "The Raw Materials of Biogas Digestion"; (4) "The Daily Operation of a Biogas Factory"; (5) "The Once a Year Cleaning of the Digester"; (6) "Tanks and Pipes: Storing and Moving Biogas"; (7) "The Factory's Products: Biogas"; (8) "The Factory's Products: Biofertilizer"; (9) "The ABCs of Safety"; and (10) "Conclusion: Profiting from an Appropriate Technology." Many diagrams are provided throughout this handbook. New ideas, composting, bioinsecticides, ferrocement, facts and figures, sources and resources, feasibility studies, problem solving, and vocabulary are presented in the appendices. (YP)

1985-07-01

336

Subcritical measurements using the /sup 252/Cf source-driven neutron noise analysis method  

Energy Technology Data Exchange (ETDEWEB)

This paper describes recent measurements of the subcritical neutron multiplication factor using the /sup 252/Cf source-driven neutron noise analysis method. This work was supported by a program of collaboration between the United States Department of Energy and the Power Reactor and Nuclear Fuel Development Corporation of Japan related to the development of fast breeder technology. The experiment reported consists of a configuration of two interacting tanks of uranyl nitrate aqueous solution with different uranium concentrations in each tank. The /sup 252/Cf-source-driven neutron noise analysis method obtains the subcriticality from the signals of three detectors: the first, a parallel plate ionization chamber with /sup 252/Cf electroplated on one of its plates that is located in or near the system containing the fissile material, and produces an electrical pulse for every spontaneous fission that occurs and thereby serves as a timed source of ...

1985-01-01

337

Study of solution for issues of an optimum operating plan in heat storing system; Chikunetsu system ni okeru saiteki un`yo keikaku mondai no kaiho ni taisuru ichikosatsu  

Energy Technology Data Exchange (ETDEWEB)

An approximate solution was proposed in which a sensitivity analysis by the storage and release of heat was performed for the subject issues and in which an operating method was thereby determined for the equipment constituting the system by means of a linear programming. Accordingly, a heat storage type energy supply system for a district cooling and heating was taken up as a concrete object to be examined. This system consisted of a gas turbine generator, initial power receiving equipment, gas boiler, electric heat pump for ice heat storage, cooling tower, heat exchanger, steam absorbing refrigerating machine, ice heat storage tank, cold and warm water heat storage tank, etc. As a result of comparison between the proposed method and the resolving method, the former showed -0.92 to 2.58% in the increase in the operating cost compared with the latter. A case where the operating cost of the resolving method was sometimes larger than the proposed ...

1996-02-01

338

Start-up control system and vessel for LMFBR  

Energy Technology Data Exchange (ETDEWEB)

A reflux condensing start-up system includes a steam generator, a start-up vessel connected parallel to the steam generator, a main steam line connecting steam outlets of the steam generator and start-up vessel to a steam turbine, a condenser connected to an outlet of the turbine and a feedwater return line connected between the condenser and inlets of the steam generator and start-up vessel. The start-up vessel has one or more heaters at the bottom thereof for heating feedwater which is supplied over a start-up line to the start-up vessel. Steam is thus generated to pressurize the steam generator before the steam generator is supplied with a heat transfer medium, for example liquid sodium, in the case of a liquid metal fast breeder reactor. The start-up vessel includes upper and lower bulbs with a smaller diameter mid-section to act as water and steam reservoirs. The start-up vessel can thus be used not only in a start-up operation but as a mixing tank, a water ...

1987-01-01

339

Replacement of fishmeal in cobia (Rachycentron canadum) diets using poultry by-product meal  

British Library Electronic Table of Contents (United Kingdom)

An 8-week feeding trial was conducted to evaluate the use of local poultry by-product meal (PBM) in replacement of imported fishmeal in the diets of cobia, Rachycentron canadum. Six isolipidic (12%) and isoproteic (45%) experimental diets were formulated using PBM to replace fishmeal at 20, 40, 60, 80 and 100% dietary protein. Eleven juvenile cobia (initial mean weight of 30.7???0.78?g) were randomly stocked in 300-L circular fibreglass tanks and hand-fed based on the total biomass of each tank, twice a day at 0900?h and 1500?h. The fish were group weighed at 2-week intervals to monitor their growth performance in order to adjust the feeding ratio. At the end of the feeding trial, weight gains (WGs) ranging from 221 to 322% were obtained. The specific growth rate (SGR), WG and protein effi...

2011-01-01

340

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be effective: (1) Removal of the particles, (2) Corrosion proofing of ...

1998-11-15

341

Methods and findings of the SNR study  

International Nuclear Information System (INIS)

A featfinding committee of the German Federal Parliament in July 1980 recommended to perform a ''risk-oriented study'' of the SNR-300, the German 300 MW fast breeder prototype reactor being under construction in Kalkar. The main aim of this study was to allow a comparative safety evaluation between the SNR-300 and a modern PWR, thus to prepare a basis for a political decision on the SNR-300. Methods and main results of the study are presented in this paper. In the first step of the risk analysis six groups of accidents have been identified which may initiate core destruction. These groups comprise all conceivable courses, potentially leading to core destruction. By reliability analyses, expected frequency of each group has been calculated. In the accident analysis potential failure modes of the reactor tank have been investigated. Core destruction may be accompanied by the release of significant amounts of mechanical energy. The primary coolant system of SNR-300 is ...

342

Design of APhF-IH Linac for a Compact Medical Accelerator  

CERN Document Server

The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage distribution along the ...

2003-01-01

343

Core and containment safety analyses for the reduction of boron concentration in the boron injection tank of Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The design boron concentration of the Boron Injection Tank (BIT) in Daya Bay Nuclear Power Station is 21000 #mu#g/g. The BIT should operate under high temperature to avoid boron crystallization, causing higher evaporation, frequent water makeup, higher deposition and pipe blockage to decrease the operability of the safety injection system. The author proposes to decrease the boron concentration in BIT from 21000 #mu#g/g to 7000 #mu#g/g to solve the existing problem. The safety analyses (core DNBR and containment response) are conducted and other impacts are evaluated for the BIT reduction. The analysis results show that the core DNBR meets the safety criterion and the containment pressure is within the design value for the steam line rupture accident after the BIT reduction. The feasibility study report of Daya bay BIT reduction has been approved by NNSA. The site implementation of BIT reduction has been finished successfully

1999-12-01

344

Adsorption/Membrane Filtration as a Contaminant Concentration and Separation Process for Mixed Wastes and Tank Wastes - Final Report  

Energy Technology Data Exchange (ETDEWEB)

This project was conducted to evaluate novel approaches for removing radioactive strontium (Sr) and cesium (Cs) from the tank wastes. The bulk of the Sr removal research conducted as part of this project investigated adsorption of Sr onto a novel adsorbent known as iron-oxide-coated sand. The second major focus of the work was on the removal of cesium. Since the chemistries of strontium and cesium have little commonality, different materials (namely, cesium scavengers known as hexacyanoferrates, HCFs) were employed in these tests. This study bridged several scientific areas and yielded valuable knowledge for implementing new technological processes. The applicability of the results extends beyond the highly specialized application niches investigated experimentally to other issues of potential interest for EMSP programs (e.g., separation of chromium from a variety of wastes using IOCS, separation of Cs from neutral and acidic wastes with EC-controlled HCFs).

1999-10-01

345

Willingness to pay for energy-saving measures in residential buildings  

Energy Technology Data Exchange (ETDEWEB)

This paper uses a choice experiment to evaluate the consumers' willingness to pay for energy-saving measures in Switzerland's residential buildings. These measures include air renewal (ventilation) systems and insulation of windows and facades. Two groups of respondents consisting respectively of 163 apartment tenants and 142 house owners were asked to choose between their housing status quo and each one of the several hypothetical situations with different attributes and prices. The estimation method is based on a fixed-effects logit model. The results suggest that the benefits of the energy-saving attributes are significantly valued by the consumers. These benefits include both individual energy savings and environmental benefits as well as comfort benefits namely, thermal comfort, air quality and noise protection. (author)

2008-03-15

346

The thermal response of an infinite line of open loop wells for ground coupled heat pump systems  

British Library Electronic Table of Contents (United Kingdom)

Ground thermal energy storage is a means of storing thermal energy underground during the summer and utilizing it during the winter. The main use of such a technology is in the heating, ventilating and air conditioning sector where the ground provides a stable temperature reservoir for a heat pump system. Heat pumps are mechanical systems that provide heating to a space in the winter, and cooling in the summer. They are increasingly popular because the same system provides both heating modes, depending on the direction of the cycle upon which they operate. The stable temperature reservoir allows the heat pump system to run at a higher efficiency. Thermal energy is transmitted to and from the ground by circulation of water through standing column geothermal wells. In commercial applications...

2011-01-01

347

Sound climate installations. Gezonde klimaatinstallaties  

Energy Technology Data Exchange (ETDEWEB)

An uncomfortable thermal climate, draft complaints and a bad airquality are often related to the climate installation. To avoid badfunctioning of the system a number of preconditions has to be fulfilledwith regard to design, planning and execution, adjustments, completion,control, maintenance and management of the installations. First threetypes of health problems in buildings are shortly discussed: buildingrelated illness, sick building syndrome and building or installationrelated complaints. Then some functions of the climate installationsare described: air filtration, filter classes and filter quality, aswell as investment costs for better filters. Next the causes for thecomplaints are dealt with: air conditioning, ventilation, air quality,and temperatures. Subsequently health affecting aspects in relation tothe climate systems are discussed: outdoor air pollution,microorganisms, bacteria (legionella pneumophila), allergies, ionneutralization and performance of ...

1989-10-01

348

Soft cooling with concrete: A simple system ensures a comfortable room climate; Sanfte Kuehlung aus Beton: Behagliches Raumklima mit einfachem System  

Energy Technology Data Exchange (ETDEWEB)

After cooling ceilings and source ventilation, simple air conditioning systems like thermal activation of concrete cores are gaining general acceptance. Parallel to this, ground source cooling systems are reducing the need for cold generation. Air conditioning systems of this type are favoured by producers of floor heating systems looking for a new market segment. [German] Nach Kuehldecken und Quellueftung gewinnen jetzt einfach aufgebaute Raumklimaanlagen, wie die thermische Betonkernaktivierung, immer mehr Anhaenger. Parallel dazu werden Verfahren zur Erdkaeltenutzung entwickelt, die den Anteil kuenstlich erzeugter Kaelte weiter zurueckdraengen. Forciert wird diese Art der Klimatisierung insbesondere durch die Hersteller von Fussbodenheizungen, fuer die sich hier ein neues Marktsegment eroeffnet. (orig.)

1999-10-01

349

Seasonal variation measurements of radon levels in caves using SSNTD method  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-15

350

Seasonal variation measurements of radon levels in caves using SSNTD method  

International Nuclear Information System (INIS)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-01

351

Respiratory exposure in buildings due to radon progeny  

International Nuclear Information System (INIS)

The #alpha# radiation dose to the lungs of people who live in buildings constructed of some granites, low density concretes, and gypsum boards is higher than for residents of most other types of dwellings due to the air-borne progeny of radon. There is evidence that sealing the interior surfaces with epoxy paint, for example, can reduce the #alpha# dose to the lung significantly without a compensating increase in whole-body exposure to the #gamma#-rays from radon progeny. Based on the incidence rates for lung cancer in uranium miners, a concentration of radon of the order of 1 to 5 pCi/l. appears to be a reasonable limit for 'lifetime' exposure indoors for 'typical' home ventilation conditions. (author).

1976-01-01

352

Radon concentration measurements in bituminous coal mines  

Energy Technology Data Exchange (ETDEWEB)

Radon measurements were carried out in Kozlu, Karadon and Uzulmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) in the study area. The radon concentration measurements were performed on a total of 42 points in those three mines. The annual exposure, the annual effective dose and lifetime fatality risk, which are the important parameters for the health of workers, were estimated based on chronic occupational exposure to the radon gas, which is calculated using UNCEAR-2000 and ICRP-65 models. The radon concentrations at several coal production faces are higher than the action level of 1000 Bq m{sup -3}. It is suggested that the ventilation rates should be rearranged to reduce the radon concentration.

2005-07-01

353

Induction motor for tunnel exhauster; Tunnel haifukiyo yudo dendoki  

Energy Technology Data Exchange (ETDEWEB)

A totally-enclosed, fan-cooled, rib-cooled type induction motor is adopted for an exhauster which is to be installed in a ventilation station for dust catcher in a tunnel. It has the highest capacity in Japan for the above purpose, and is provided with a cooling fan inside to recirculate cooled air, thereby improving cooling efficiency and reducing size and weight. Three-row combined angular ball bearings are used as the thrust bearings, and grease lubrication system is adopted to simplify the inspection/maintenance works. It is to be delivered to Japan Highway Public Corporation's Shizuoka Construction Bureau, Yaizu site office. Its electric specifications are 455 kW, 440 V, 890 A and 510 rpm, and its mechanical specifications are thrust load: 16 kN and impeller load: 7.2 kN. (translated by NEDO)

2000-01-10

354

Improvement of methane drainage in high gassy coal seam using waterjet technique  

Energy Technology Data Exchange (ETDEWEB)

Traditional methane drainage methods, including conventional ventilation and boreholes drilled in the coal seam, are widely used in modern coal mining operation in China. However, it is often noted that the gas drainage presents low efficiency in most coal mines due to low permeability of the coal seam, which not only affects the safety, but also the productivity of the coal mine. This paper describes the development and application of the waterjet cutting system, which is used to create artificial fractures and increase the permeability of coal seam for the improvement of methane drainage in underground coal mines in China. According to underground monitoring, a significant improvement of methane drainage efficiency of up to 3 to 6 times over the traditional methods has been achieved. (author)

2009-07-01

355

High-level waste canister storage final design, installation, and testing. Topical report  

Energy Technology Data Exchange (ETDEWEB)

This report is a description of the West Valley Demonstration Project`s radioactive waste storage facility, the Chemical Process Cell (CPC). This facility is currently being used to temporarily store vitrified waste in stainless steel canisters. These canisters are stacked two-high in a seismically designed rack system within the cell. Approximately 300 canisters will be produced during the Project`s vitrification campaign which began in June 1996. Following the completion of waste vitrification and solidification, these canisters will be transferred via rail or truck to a federal repository (when available) for permanent storage. All operations in the CPC are conducted remotely using various handling systems and equipment. Areas adjacent to or surrounding the cell provide capabilities for viewing, ventilation, and equipment/component access.

1998-04-01

356

Heat and mass transfer analogy studies of binary liquid mixture in comparison with ethanol-n-heptane evaporating to air  

Energy Technology Data Exchange (ETDEWEB)

An experimental and theoretical study of heat and mass transfer analogy and a comparison of that to a binary liquid mixture evaporation is presented. Common organic solvents, ethanol and n-heptane, were used to form an alcohol - hydrocarbon mixture. Studies were carried out in a horizontal rectangular channel having air flow velocities of 0.2 - 0.9 m/s. Heat transfer coefficients were measured with a copper plate resistor and mass transfer coefficients with a square pool. The heat and mass transfer analogy is presented for a system having two evaporating compounds with a fixed value of air flow and verified by measuring and comparing mass transfer coefficients for distilled water with air flow velocities of 0.2 - 0.9 m/s. An illustrative example of the use of the theory for industrial ventilation is presented. (author)

1995-12-31

357

General flow and thermal boundary conditions in indoor air flow simulation  

Energy Technology Data Exchange (ETDEWEB)

The concepts of general flow and thermal boundary conditions are introduced to treat the interaction between indoor and outdoor thermal environments in computational fluid dynamics (CFD) simulations. The results from a multi-zone model are used to supply the general flow boundary conditions. The energy balance equation at wall-air interfaces is used to supply the general thermal boundary conditions. An example calculation in a 13-room building shows that infiltration influences indoor air flow patterns considerably. The air flow in a room ventilated by displacement is measured and simulated. Two surface coatings are considered, i.e. black walls and aluminum walls. Implementation of these two boundary conditions is essential in predicting air flow patterns, air quality, and thermal comfort in a real building. (author)

1994-12-31

358

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ventilation. Today, MRI is considered the method ...

359

Contents of polycyclic aromatic hydrocarbons (PAH) and phenolic substances in Frankfurter-type sausages depending on smoking conditions using glow smoke  

British Library Electronic Table of Contents (United Kingdom)

The contents of polycyclic aromatic hydrocarbons (PAH) and phenolic substances in Frankfurter-type sausages were investigated depending on hot smoking conditions (glow smoke). For the 24 smoking experiments (performed in duplicates) three different smoke densities and ventilator velocities as well as wood chips with five different moisture contents were tested. During the smoking process, concentrations of O"2, CO"2 and CO, humidity and temperature in the smoking chamber as well as smoke generation temperature were determined. The chemical analysis included the contents of the 15+1 EU priority PAH and the phenolic substances guaiacol, 4-methylguaiacol, syringol, eugenol and trans-isoeugenol. The smoking conditions had a significant influence on smoke generation temperature, organoleptic pr...

2012-01-01

360

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

361

Air conditioning in high rise buildings; Conditionnement d'air dans les immeubles de grande hauteur  

Energy Technology Data Exchange (ETDEWEB)

This two-tomes book brings together the 108 presentations given at the first conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: general design and control systems, including split systems, radiant panels, fluctuating and gravity ventilation etc..; energy consumption, optimization and heat recovery; cold storage for peak shaving, including ice slurry circulation; indoor air quality; fire and smokes protection, protection against chimney effects and lighting spots; use of fuzzy logic and of neural networks. It includes also a description of the high rise building situation and works in progress in China, Japan and in some other countries. (J.S.)

1997-07-01

362

Wind-To-Hydrogen Project: Operational Experience, Performance Testing, and Systems Integration  

Energy Technology Data Exchange (ETDEWEB)

The Wind2H2 system is fully functional and continues to gather performance data. In this report, specifications of the Wind2H2 equipment (electrolyzers, compressor, hydrogen storage tanks, and the hydrogen fueled generator) are summarized. System operational experience and lessons learned are discussed. Valuable operational experience is shared through running, testing, daily operations, and troubleshooting the Wind2H2 system and equipment errors are being logged to help evaluate the reliability of the system.

2009-03-01

363

WATER SUPPLY ANALYSIS  

Energy Technology Data Exchange (ETDEWEB)

This analysis defines and evaluates the surface water supply system from the existing J-13 well to the North Portal. This system includes the pipe running from J-13 to a proposed Booster Pump Station at the intersection of H Road and the North Portal access road. Contained herein is an analysis of the proposed Booster Pump Station with a brief description of the system that could be installed to the South Portal and the optional shaft. The tanks that supply the water to the North Portal are sized, and the supply system to the North Portal facilities and up to Topopah Spring North Ramp is defined.

1996-02-06

364

Relining of scrubbers in flue gas desulfurization plants  

Science.gov (United States)

Rubber lining is used as a corrosion protection material in European flue gas desulfurization plants, for scrubbers, tanks, pipe systems, etc. Although these rubber linings can last more than 15 years, relining still is necessary. The difficulty of shutting down power station units requires that the time scale of this replacement be kept to a minimum. High-pressure water systems have proven successful as an efficient method for removal of the old lining. The working steps and time scale are demonstrated for one such relining case.

1999-09-01

365

R&D prioritization and resource management for technology selection  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a decision approach, and associated computer software tools, for prioritizing and selecting among technology development activities. The approach elicits and then summarizes technology development preferences from stakeholders, and then integrates preferences into a set of funding recommendations. By formalizing the technology review process, the decision approach builds consensus and clarifies the basis for final budget decisions. The software development was conducted jointly by Pacific Northwest Laboratory and Decisions Science Associates, Incorporated. The Underground Storage Tank Integrated Demonstration funded the task; however, the approach should also be valuable to the US Department of Energy Office of Technology Development, the Office of Waste Management, and the Office of Environmental Restoration.

1994-03-01

366

Projected radionuclide inventories of DWPF glass from current waste at time of production. Revision 1  

Energy Technology Data Exchange (ETDEWEB)

The Waste Acceptance Preliminary Specifications (WAPS) require that the DWPF estimate the inventory of long-lived radionuclides present in the waste glass, and report the values in the Waste Form Qualification Report. In this report, conservative (biased high) estimates of the radionuclide inventory of glass produced from waste currently in the Tank Farm are provided. In most cases, these calculated values compare favorably with actual data. In those cases where the agreement is not good, the values reported here are conservative.

1993-02-04

367

Innovative active control of gun barrels using smart materials  

Science.gov (United States)

The accuracy of stabilized, turreted gun systems like the 120mm gun on the M1A2 Abrams tank and the 30mm gun on the Apache helicopter are limited by, among other things, structural flexure of the gun barrel and support structure. An advanced actuation system based on piezoelectric translators and an optical fiber strain sensing system are described in conjunction with a rapid prototyping workstation for the design of distributed parameter control systems to actively minimize the effects of vibrations caused by traversing rough terrain or weapon firing.

1997-06-01

368

Direct dark matter identification with a hybrid detection technique  

CERN Document Server

In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.

2008-01-01

369

Development of the alcohol waste processing equipment  

International Nuclear Information System (INIS)

In the experimental fast Reactor JOYO, gripper of Fuel Handling Machine and Ex-Vessel Transfer Machine that the sodium adhered is being washed with alcohol. This radioactive alcohol waste that was used to the washing is stored to the tank. If it is able to separate the alcohol and sodium in the alcohol waste it becomes possible to dispose of the alcohol waste. Japan Nuclear Institute and Fuji Electric Systems CO., LTD. Developed the device that adds carbonic acid gas to the alcohol waste and cause the sodium in the alcohol waste separated as carbonate and remove this carbonate by using the thin film evaporator. (author)

2004-11-01

370

Corrosion 2003. Conference papers on CD-ROM  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.

2003-07-01

371

Compressed hydrogen fuelled vehicles: reasons of a choice and developments in ENEA  

Energy Technology Data Exchange (ETDEWEB)

Some recent achievements in the field of high pressure vessels and safety devices have offered a concrete chance to the application of compressed hydrogen for fleet commercial vehicles for urban use. Accordingly with this concept, ENEA has modified a Fiat Ducato van with a dual fuel engine, retaining the gasoline tank for long distance travelling and adopting the external mixture formation technique, with hydrogen injectors developed by ENEA, for non-polluting short-range duties in urban traffic. The article deals with the rationale for this choice and gives a general view of the project. (author)

1996-12-01

372

Bringing robotics technology down to Earth  

International Nuclear Information System (INIS)

Robotics technology is successfully being transitioned from space to terrestrial applications. It is being modified and enhanced to help in the US DOE's Environmental Restoration and Waste Management Program. Some examples of these applications, ranging from large multijointed manipulators to autonomously navigated remote vehicles, are outlined in this article. They include the following: underground storage tank technology demonstration; light-duty utility arm system; remotely controlled material-handling system; remotely operated excavator; self-guided transfer vehicle. 10 figs.

373

Analysis of hydrogen vehicles with cryogenic high pressure storage  

Energy Technology Data Exchange (ETDEWEB)

Insulated pressure vessels are cryogenic-capable pressure vessels that can be fueled with liquid hydrogen (LIQ) or ambient-temperature compressed hydrogen (CH2). Insulated pressure vessels offer the advantages of liquid hydrogen tanks (low weight and volume), with reduced disadvantages (lower energy requirement for hydrogen liquefaction and reduced evaporative losses). This paper shows an evaluation of the applicability of the insulated pressure vessels for light-duty vehicles. The paper shows an evaluation of evaporative losses and insulation requirements and a description of the current experimental plans for testing insulated pressure vessels. The results show significant advantages to the use of insulated pressure vessels for light-duty vehicles.

1998-06-19

374

Thin-film evaporator recovers solvents continuously  

Energy Technology Data Exchange (ETDEWEB)

Reclaimed Energy Company, Inc., Connersville, IN, receives waste generated from a wide variety of industrial applications which include paint, printing and degreasing companies. The wastes are stored in separate tanks and then distilled in batches (pot distillation). The recovered solvents can be returned to the originator. The residue, left after the solvents are distilled, is disposed of using an environmentally safe, economical procedure. The company worked with an engineering and fabrication firm to develop a continuous processing system that employs a mechanically agitated thin-film evaporator to distill the solvents. Successful performance of the evaporator was ensured by processing samples of solvents through the evaporator manufacturer's pilot plant facilities before the full-sized system was designed. Reclaimed Energy Company, Inc., has realized a number of advantages by going from pot distillation to the agitated thin-film evaporator system to ...

1985-11-01

375

Stationary low power reactor No. 1 (SL-1) accident site decontamination & dismantlement project  

Science.gov (United States)

The Army Reactor Area (ARA) II was constructed in the late 1950s as a test site for the Stationary Low Power Reactor No. 1 (SL-1). The SL-1 was a prototype power and heat source developed for use at remote military bases using a direct cycle, boiling water, natural circulation reactor designed to operate at a thermal power of 3,000 kW. The ARA II compound encompassed 3 acres and was comprised of (a) the SL-1 Reactor Building, (b) eight support facilities, (c) 50,000-gallon raw water storage tank, (d) electrical substation, (e) aboveground 1,400-gallon heating oil tank, (f) underground 1,000-gallon hazardous waste storage tank, and (g) belowground power, sewer, and water systems. The reactor building was a cylindrical, aboveground facility, 39 ft in diameter and 48 ft high. The lower portion of the building contained the reactor pressure vessel surrounded by gravel shielding. Above the pressure vessel, in the center portion ...

1995-11-01

376

Salt decontamination demonstration test results  

International Nuclear Information System (INIS)

The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a factor of 26 to less ...

377

Energy use in swine unit in the finishing system with waste treatment; Uso de energia em unidade suinicola em sistema de terminacao com tratamento de residuos  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess the energy flux and energetic balance related to the swine production and the recycling of residues generated by the system for utilization as organic fertilizers. The experiment was carried out at Vale dos Ipes Farm, located in the city of Ouro Verde do Oeste, in the Western of Parana State. One finishing phase swine unity containing 600 animals was monitored from January to June 2005. The treatment system is composed by one steel digester with capacity for 50 m{sup 3}, one sedimentation tank, one algae tank and one bio fertilizer storage tank. The swine barn cleaning is performed by dry scratching on a daily basis. The generated residues flow by gravitation through ducts towards the digester. The duration of the hydraulic retention period was 12 days. In the calculation of energetic efficiency, the energetic component ration is the greatest energetic cost in production system of ...

2006-07-01

378

Comparison between experimental data and numerical modeling for the natural circulation phenomenon  

Energy Technology Data Exchange (ETDEWEB)

There is a crescent interest in the scientific community in the study of natural circulation phenomenon. New generation of compact nuclear reactors uses the natural circulation of the fluid as a system of cooling and of residual heat removal in case of accident or shutdown. The objective of this paper is to present a study through the comparison of experimental data and numerical simulation for the natural circulation phenomenon in one and two-phase flow regime. An experimental circuit built with glass tubes is used for the experiments. Thus, it allows the thermal hydraulic phenomena visualization. There is an electric heater as the heat source, a heat exchanger as the heat sink and an expansion tank to accommodate fluid density excursions. The circuit instrumentation consists of thermocouples and pressure meters to better keep track of the flow and heat transfer phenomena. Instrumentation data acquisition is performed through a computer interface developed with ...

2009-07-01

379

Closure Report for Corrective Action Unit 543: Liquid Disposal Units, Nevada Test Site, Nevada  

Energy Technology Data Exchange (ETDEWEB)

This Closure Report (CR) documents closure activities for Corrective Action Unit (CAU) 543, Liquid Disposal Units, according to the Federal Facility Agreement and Consent Order (FFACO, 1996) and the Corrective Action Plan (CAP) for CAU 543 (U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office [NNSA/NSO], 2007). CAU 543 is located at the Nevada Test Site (NTS), Nevada (Figure 1), and consists of the following seven Corrective Action Sites (CASs): CAS 06-07-01, Decon Pad; CAS 15-01-03, Aboveground Storage Tank; CAS 15-04-01, Septic Tank; CAS 15-05-01, Leachfield; CAS 15-08-01, Liquid Manure Tank; CAS 15-23-01, Underground Radioactive Material Area; CAS 15-23-03, Contaminated Sump, Piping; and CAS 06-07-01 is located at the Decontamination Facility in Area 6, adjacent to Yucca Lake. The remaining CASs are located at the former U.S. Environmental Protection Agency (EPA) Farm in Area 15. The ...

2008-01-01

380

Spent Fuel Background Report Volume I  

Energy Technology Data Exchange (ETDEWEB)

This report is an overview of current spent nuclear fuel management in the DOE complex. Sources of information include published literature, internal DOE documents, interviews with site personnel, and information provided by individual sites. Much of the specific information on facilities and fuels was provided by the DOE sites in response to the questionnaire for data for spent fuels and facilities data bases. This information is as accurate as is currently available, but is subject to revision pending results of further data calls. Spent fuel is broadly classified into three categories: (a) production fuels, (b) special fuels, and (c) naval fuels. Production fuels, comprising about 80% of the total inventory, are those used at Hanford and Savannah River to produce nuclear materials for defense. Special fuels are those used in a wide variety of research, development, and testing activities. Special fuels include fuel from DOE and commercial reactors used in ...

1994-03-01

381

Radiological dose assessment for the decontaminated concrete removed from 183-H solar evaporation basins at the Hanford site, Richland, Washington  

Energy Technology Data Exchange (ETDEWEB)

Potential maximum radiation dose rates over a 1,000-year time horizon were calculated for exposure to the decontaminated concrete removed from the 183-H Solar Evaporation Basins at the Hanford Site, Richland, Washington. The RESRAD computer code, Version 5.62, which implements the methodology described in the US Department of Energy`s manual for developing residual radioactive material guidelines, was used in this evaluation. Currently, the concrete is not being used. Four potential exposure scenarios were developed for the land area where the decontaminated concrete will be stored. In Scenario A industrial use of the land is assumed; in Scenario B recreational use of the land is assumed; in Scenario C residential use of the land is assumed; and in Scenario D (a plausible but unlikely land-use scenario), the presence of a subsistence farmer in the immediate vicinity of the land is assumed. For Scenarios A and B, water used for drinking is assumed to be surface ...

1997-01-01

382

Operational safety experience and passive safety testing at the FFTF  

International Nuclear Information System (INIS)

The FFTF is a 400-MWt sodium-cooled fast neutron flux test reactor located on the US government-owned Hanford Site in southeastern Washington state. The reactor is operated for the US Department of Energy by the Westinghouse Hanford Company. Since FFTF started routine operation in 1982, the commercially fabricated driver fuel has performed flawlessly to well beyond the design goal peak burnup of 80 MWd/kgM. The core average discharge exposure is now some 60% beyond the original design expectations and attests to the ruggedness and reliability of the mixed oxide fuel system. In Cycle 9 sixteen long-life assemblies were installed to begin the irradiation of mixed oxides in the advanced low-swelling alloy HT-9 as the Core Demonstration Experiment (CDE). Operation of the plant from initial startup testing to ten cycles of operation has confirmed that the nuclear characteristics are well within the design predictions, and all parameters have ...

1987-10-21

383

Microbial characterization of a radionuclide- and metal-contaminated waste site  

Energy Technology Data Exchange (ETDEWEB)

The operation of nuclear processing facilities and defense-related nuclear activities has resulted in contamination of near-surface and deep-subsurface sediments with both radionuclides and metals. The presence of mixed inorganic contaminants may result in undetectable microbial populations or microbial populations that are different from those present in uncontaminated sediments. To determine the impact of mixed radionuclide and metal contaminants on sediment microbial communities, we sampled a processing pond that was used from 1948 to 1975 for the disposal of radioactive and metal-contaminated wastewaters from laboratories and nuclear fuel fabrication facilities on the Hanford Site in Washington State. Because the Hanford Site is located in a semiarid environment with average rainfall of 159 mm/year, the pond dried and a settling basin remained after wastewater input into the pond ceased in 1975. This processing pond basin offered a unique ...

1993-04-01

384

Hanford Site pollution prevention progress report  

Energy Technology Data Exchange (ETDEWEB)

The Richland Operations Office (RL) and Office of River Protection (ORP) are pleased to issue the attached Pollution Prevention Progress Report. We have just met the most aggressive waste reduction and A recycling goals to date and are publishing this report to recognize A the site's progress, and to ensure it will sustain success beyond 1 Fiscal Year 2000. This report was designed to inform the been made by RL and ORP in Waste Minimization (WMin) and Pollution Prevention (P2). RL, ORP and their contractors are committed to protecting the environment, and we reiterate pollution prevention should continue to be at the forefront of the environmental cleanup and research efforts. As you read the attached report, we believe you will see a clear demonstration of RL and ORP's outstanding performance as it has been responsible and accountable to the nation, its employees, and the community in which we live and work. commitment that all employees have for environmental ...

1999-10-05

385

Combined Estimation of Hydrogeologic Conceptual Model, Parameter, and Scenario Uncertainty with Application to Uranium Transport at the Hanford Site 300 Area  

Energy Technology Data Exchange (ETDEWEB)

This report to the Nuclear Regulatory Commission (NRC) describes the development and application of a methodology to systematically and quantitatively assess predictive uncertainty in groundwater flow and transport modeling that considers the combined impact of hydrogeologic uncertainties associated with the conceptual-mathematical basis of a model, model parameters, and the scenario to which the model is applied. The methodology is based on a n extension of a Maximum Likelihood implementation of Bayesian Model Averaging. Model uncertainty is represented by postulating a discrete set of alternative conceptual models for a site with associated prior model probabilities that reflect a belief about the relative plausibility of each model based on its apparent consistency with available knowledge and data. Posterior model probabilities are computed and parameter uncertainty is estimated by calibrating each model to observed system behavior; prior parameter estimates are optionally ...

2007-07-30

386

1993 Annual report on waste generation and waste minimization progress as required by DOE Order 5400.1, Hanford Site  

International Nuclear Information System (INIS)

More important than waste generation numbers, the pollution prevention and waste minimization successes achieved at Hanford in 1993 have reduced waste and improved operations at the Site. Just a few of these projects are: A small research nuclear reactor, unused and destined for disposal as low level radioactive waste, was provided to a Texas University for their nuclear research program, avoiding 25 cubic meters of waste and saving $116,000. By changing the slope on a asphalt lot in front of a waste storage pad, run-off rainwater was prevented from becoming mixed low level waste water, preventing 40 cubic meters of waste and saving $750,000. Through more efficient electrostatic paint spraying equipment and a solvent recovery system, a paint shop reduced hazardous waste by 3,500 kilograms, saving $90,800. During the demolition of a large decommissioned building, more than 90% of the building's material was recycled by crushing the concrete for use on-Site and ...

387

Health-hazard evaluation report HETA 84-427-1613, Pikes Peak Dialysis Center, Colorado Springs, Colorado  

Energy Technology Data Exchange (ETDEWEB)

Environmental and breathing zone samples were analyzed for formaldehyde at the Pikes Peak Dialysis Center, Colorado Springs, Colorado in August, 1984 and February, 1985. The evaluation was requested by a representative of the Center to determine if there was a health hazard due to formaldehyde. Eight employees were interviewed. The ventilation systems were investigated. Personal protective clothing was inspected. Breathing-zone samples contained 0 28 to 1.0 (mg/m/sup 3/) formaldehyde. The OSHA standard for formaldehyde is 3.7 mg/m/sup 3/. Area formaldehyde concentrations ranged from nondetectable to 0.75 mg/m/sup 3/. Health complaints reported included sore throat, congestion, cough, and eye, nose and throat irritation. Most of the complaints originated from employees in the formalin mixing, reuse sterilization, and dialysis unit packing sections. The exhaust system in the reuse sterilization area was not working efficiently. A variety of personal protective ...

1985-08-01

388

Energy policy for integrating the building environmental performance model of an air conditioned building in a subtropical climate  

Energy Technology Data Exchange (ETDEWEB)

For an air conditioned building, the major electricity consumption is by the heating, and air conditioning (HVAC) system. As energy saving strategies may be in conflict with the criteria of indoor air quality and thermal comfort, a concept of the building environmental performance model (BEPM) has been developed to optimize energy consumption in HVAC systems without any deterioration of the indoor air quality and thermal comfort. The BEPM is divided into two main modules: the adaptive comfort temperature (ACT) module and the new demand control ventilation (nDCV) module. This study aims to enhance and prompt the conventional operation of the air side systems by incorporating temperature reset with the adaptive comfort temperature control and the new demand control ventilation system in high rise buildings in Hong Kong. A new example weather year (1991) was established as a reference to compute the energy use of HVAC systems in buildings in order ...

2006-09-15

389

Hydrogen storage in nano-structured carbon materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical ...

2005-07-01

390

Hydrogen storage in nano-structured carbon materials  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical ...

2005-07-01

391

Waste sampling and characterization facility (WSCF) maintenance implementation plan  

Energy Technology Data Exchange (ETDEWEB)

This Maintenance Implementation Plan (MIP) is written to satisfy the requirements of the US Department of Energy (DOE) Order 4330.4B, Maintenance Management Program that specifies the general policy and objectives for the establishment of the DOE controlled maintenance programs. These programs provide for the management and performance of cost effective maintenance and repair of the DOE property, which includes facilities. This document outlines maintenance activities associated with the facilities operated by Waste Management Hanford, Inc. (WMH). The objective of this MIP is to provide baseline information for the control and execution of WMH Facility Maintenance activities relative to the requirements of Order 4330.4B, assessment of the WMH maintenance programs, and actions necessary to maintain compliance with the Order. Section 2.0 summarizes the history, mission and description of the WMH facilities. Section 3.0 describes maintenance scope and requirements, ...

1997-08-13

392

Quality assurance requirements for high-level waste form production  

International Nuclear Information System (INIS)

The US Department of Energy (DOE) Defense Waste Management Plan has the objective of final disposal for high-level waste (HLW) generated from defense programs. The DOE sites that generate HLW are located at the Savannah River Operations Office in Aiken, South Carolina, the Hanford site in Richland, Washington, and the Idaho Operations Office in Idaho Falls, Idaho. The purpose in the development of a quality assurance (QA) specification for organizations involved in HLW production is to establish uniform requirements that ensure that radioactive waste is converted to a waste form and canistered in such a way that it is acceptable in a federal repository licensed by the US Nuclear Regulatory Commission (NRC). A QA specification has been developed that will be applied to those activities important to certification of the product. The basic requirements are defined in national consensus standards and DOE directives. The supplemental requirements identify the QA ...

1988-06-12

393

Overview of the 1995 NATO ARW on nuclear submarine decommissioning and related problems  

International Nuclear Information System (INIS)

The NATO Advanced Research Workshop on Nuclear Submarine Decommissioning and Related Problems was held in Moscow June 19--22, 1995. It was preceded by a visit to the Zvezdotchka Shipyard at Severodvinsk, a repair and maintenance yard for Russian nuclear submarines, for a subgroup of the workshop attendees. Most of the material in this paper is drawn directly form the workshop proceedings. Slightly less than 500 nuclear ships and submarines (the vast majority are submarines) have been constructed by the countries with nuclear navies. This includes approximately 250 by Russia, 195 by the United States, 23 by the United Kingdom, 11 by France and 6 by China. By the year 2000 it is expected that approximately one-half of these nuclear vessels will be removed from service and in various states of decommissioning. A newspaper account in June 1997 indicated that 156 Russian nuclear submarines had been removed from service. In August 1996 it was reported that 55 reactor compartment sections ...

1997-11-21

394

Maintenance implementation plan for the Plutonium Finishing Plant. Revision 3  

Energy Technology Data Exchange (ETDEWEB)

This document outlines the Maintenance Implementation Plan (MIP) for the Plutonium Finishing Plant (PFP) located at the Hanford site at Richland, Washington. This MIP describes the PFP maintenance program relative to DOE order 4330.4B. The MIP defines the key actions needed to meet the guidelines of the Order to produce a cost-effective and efficient maintenance program. A previous report identified the presence of significant quantities of Pu-bearing materials within PFP that pose risks to workers. PFP`s current mission is to develop, install and operate processes which will mitigate these risks. The PFP Maintenance strategy is to equip the facility with systems and equipment able to sustain scheduled PFP operations. The current operating run is scheduled to last seven years. Activities following the stabilization operation will involve an Environmental Impact Statement (EIS) to determine future plant activities. This strategy includes long-term maintenance of the ...

1996-03-01

395

Maintenance implementation plan for the B Plant/WESF. Revision 4  

Energy Technology Data Exchange (ETDEWEB)

This Maintenance Implementation Plan (MIP) has been developed for maintenance functions associated with the B Plant/WESF (Waste Encapsulation Storage Facility) complex. The objective of this plan is to provide baseline information for establishing and identifying WHC conformance programs and policies applicable to implementation of DOE order 4330.4B guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost-effective and efficient maintenance program at B Plant/WESF. The B Plant WESF facility complex consists of three main facilities and several support structures located in the 200 East Area of the Hanford site. B Plant is a transition facility that is required to ensure safe storage and management of WESF (operating facility) cesium and strontium capsules. B Plant/WESF also contains substantial radiological inventory from previous campaigns. There are no production activities at B Plant, but several of its operating systems ...

1996-01-01

396

Maintenance Implementation Plan for solid waste  

Energy Technology Data Exchange (ETDEWEB)

This Maintenance Implementation Plan (MIP) has been developed for. implementation of the US Department of Energy (DOE) Order 4330.4A. Maintenance Implementation Program (DOE 1990) at the Hanford Site Solid Waste complex. It addresses maintenance functions associated with Solid Waste Management, which includes the field operational group and the facilities operational group. An assessment of the existing maintenance programs for Solid Waste was performed, and the results of this assessment were evaluated to determine corrective actions required to bring Solid Waste Maintenance into compliance with the order. The MIP assessment disclosed that most elements defined in the order are currently implemented for Solid Waste. It also identified issues which must be addressed to bring the maintenance function into full compliance with DOE Order 4330.4A. These include documentation of the maintenance training program, expanded scope of inspections to address the As Low As ...

1992-06-01

397

HEMISPHERIC CENTER FOR ENVIRONMENTAL TECHNOLOGY  

Energy Technology Data Exchange (ETDEWEB)

FIU-HCET participated in an ICT meeting at Mound during the second week of December and presented a brief videotape of the testing of the Robotic Climber technology. During this meeting, FIU-HCET proposed the TechXtract technology for possible testing at Mound and agreed to develop a five-page proposal for review by team members. FIU-HCET provided assistance to Bartlett Inc. and General Lasertronics Corporation in developing a proposal for a Program Opportunity Notice (PON). The proposal was submitted by these companies on January 5, 1999. The search for new equipment dismantlement technologies is continuing. The following vendors have responded to requests for demonstration: LUMONICS, Laser Solutions technology; CRYO-BEAM, Cryogenic cutting technology; Waterjet Technology Association, Waterjet Cutting technology; and DIAJET, Waterjet Cutting technology. Based on the tasks done in FY98, FIU-HCET is working closely with Numatec Hanford Corporation (NHC) and Pacific ...

1999-01-31

398

G3 model of gas and liquid migration from grout containing radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

Grout has been evaluated as a means of containing low-level radioactive waste for long-term disposal. Concerns about hydrogen and reactive gas generation in the Hanford Site grout disposal facility lead to the development of the G3 model, which has predicted buildup of radiolytically formed gases in the grout region and their migration to air-filled regions. The G3 model is a one-dimensional code that couples models of gas diffusion with two-phase gas and liquid flow. It was coupled to a compartment diffusion model and these models predicted the concentrations of hydrogen I nitrous oxide, and other gases in air-filled regions of the grout disposal facility. The results have served as the technical basis for safety studies. A unique finding of the G3 model was that a liquid return, or expulsion of unbound liquid from the grout region, could occur. This liquid return is driven by displacement caused by gas bubbles that form within the grout`s microstructure. Liquid ...

1994-11-01

399

Fuel storage basin seismic analysis  

International Nuclear Information System (INIS)

The 105-KE and 105-KW Fuel Storage Basins were constructed more than 35 years ago as repositories for irradiated fuel from the K East and K West Reactors. Currently, the basins contain irradiated fuel from the N Reactor. To continue to use the basins as desired, seismic adequacy in accordance with current US Department of Energy facility requirements must be demonstrated. The 105-KE and 105-KW Basins are reinforced concrete, belowground reservoirs with a 16-ft water depth. The entire water retention boundary, which currently includes a portion of the adjacent reactor buildings, must be qualified for the Hanford Site design basis earthquake. The reactor building interface joints are sealed against leakage with rubber water stops. Demonstration of the seismic adequacy of these interface joints was initially identified as a key issue in the seismic qualification effort. The issue of water leakage through seismicly induced cracks was also investigated. This issue, ...

1991-10-15

400

Fast Flux Test Facility (FFTF) standby plan  

Energy Technology Data Exchange (ETDEWEB)

The FFTF Standby Plan, Revision 0, provides changes to the major elements and project baselines to maintain the FFTF plant in a standby condition and to continue washing sodium from irradiated reactor fuel. The Plan is consistent with the Memorandum of Decision approved by the Secretary of Energy on January 17, 1997, which directed that FFTF be maintained in a standby condition to permit the Department to make a decision on whether the facility should play a future role in the Department of Energy`s dual track tritium production strategy. This decision would be made in parallel with the intended December 1998 decision on the selection of the primary, long- term source of tritium. This also allows the Department to review the economic and technical feasibility of using the FFTF to produce isotopes for the medical community. Formal direction has been received from DOE-RL and Fluor 2020 Daniel Hanford to implement the FFTF standby decision. The objective of the Plan ...

1997-03-06

401

Facility Effluent Monitoring Plan for Pacific Northwest National Laboratory Balance-of-Plant Facilities  

Energy Technology Data Exchange (ETDEWEB)

The Pacific Northwest National Laboratory (PNNL) operates a number of research and development (R and D) facilities for the Department of Energy on the Hanford Site. According to DOE Order 5400.1, a Facility Effluent Monitoring Plan is required for each site, facility, or process that uses, generates, releases, or manages significant pollutants or hazardous materials. Three of the R and D facilities: the 325, 331, and 3720 Buildings, are considered major emission points for radionuclide air sampling and thus individual Facility Effluent Monitoring Plans (FEMPs) have been developed for them. Because no definition of ''significant'' is provided in DOE Order 5400.1 or the accompanying regulatory guide DOE/EH-0173T, this FEMP was developed to describe monitoring requirements in the DOE-owned, PNNL-operated facilities that do not have individual FEMPs. The remainder of the DOE-owned, PNNL-operated facilities are referred to as ...

1999-04-02

402

FFTF fission gas monitor computer system  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated gamma source can be ...

403

Electrometallurgical treatment of aluminum-matrix fuels  

Energy Technology Data Exchange (ETDEWEB)

The electrometallurgical treatment process described in this paper builds on our experience in treating spent fuel from the Experimental Breeder Reactor (EBR-II). The work is also to some degree, a spin-off from applying electrometallurgical treatment to spent fuel from the Hanford single pass reactors (SPRs) and fuel and flush salt from the Molten Salt Reactor Experiment (MSRE) in treating EBR-II fuel, we recover the actinides from a uranium-zirconium fuel by electrorefining the uranium out of the chopped fuel. With SPR fuel, uranium is electrorefined out of the aluminum cladding. Both of these processes are conducted in a LiCl-KCl molten-salt electrolyte. In the case of the MSRE, which used a fluoride salt-based fuel, uranium in this salt is recovered through a series of electrochemical reductions. Recovering high-purity uranium from an aluminum-matrix fuel is more challenging than treating SPR or EBR-II fuel because the aluminum- matrix fuel is typically -90% ...

1996-08-01

404

Calculation of groundwater travel time  

Energy Technology Data Exchange (ETDEWEB)

Pre-waste-emplacement groundwater travel time is one indicator of the isolation capability of the geologic system surrounding a repository. Two distinct modeling approaches exist for prediction of groundwater flow paths and travel times from the repository location to the designated accessible environment boundary. These two approaches are: (1) the deterministic approach which calculates a single value prediction of groundwater travel time based on average values for input parameters and (2) the stochastic approach which yields a distribution of possible groundwater travel times as a function of the nature and magnitude of uncertainties in the model inputs. The purposes of this report are to (1) document the theoretical (i.e., mathematical) basis used to calculate groundwater pathlines and travel times in a basalt system, (2) outline limitations and ranges of applicability of the deterministic modeling approach, and (3) explain the motivation for the use of the stochastic modeling ...

1984-12-01

405

222-S Laboratory maintenance implementation plan  

Energy Technology Data Exchange (ETDEWEB)

This Maintenance Improvement Plan has been developed for maintenance functions associated with the 222-S Laboratory. This plan is developed from the guidelines presented by Department of Energy (DOE) Order 4330.4B, Maintenance Management Program (DOE 1994), Chapter 11. The objective of this plan is to provide information for establishing and identifying WMH conformance programs and policies applicable to implementation of DOE Order 4330.4B guidelines. In addition, this maintenance plan identifies the actions necessary to develop a cost effective and efficient maintenance program at 222-S Laboratory. Maintenance activities are mainly going to be performed by existing maintenance organizations within Waste Management Federal Services of Hanford (WMH). Most maintenance performed at 222-S Laboratory is performed by the 222-S Laboratory maintenance organization. This 222-S Laboratory Maintenance Implementation Plan provides the interface requirements and ...

1997-08-13

406

The advanced MAPLE reactor concept  

International Nuclear Information System (INIS)

High-flux neutron sources are continuing to be of interest both in Canada and internationally to support materials testing for advanced power reactors, new developments in extracted-neutron-beam applications, and commercial production of selected radioisotopes. The advanced MAPLE reactor concept has been developed to meet these needs. The advanced MAPLE reactor is a new tank-type D_2O reactor that uses rodded low-enrichment uranium fuel in a compact annular core to generate peak thermal-neutron fluxes of 1 x 10"1"9 n#centre dot#s"-"1 in a central irradiation rig with a thermal power output of 50 MW. Capital and incremental development costs are minimized by using MAPLE reactor technology to the greatest extent practicable.

1985-10-14

407

Surveillance and maintenance activities of waste area groupings at Oak Ridge National Laboratory. Annual summary report for period ending September 30, 1991: Environmental Restoration Program  

Energy Technology Data Exchange (ETDEWEB)

Surveillance and maintenance (S & M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S & M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S & M Program are met by maintaining a program of routine S & M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program`s activities and includes tables indicating tank levels and dry well data for FY 1991.

1991-12-01

408

Surveillance and maintenance activities of waste area groupings at Oak Ridge National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

Surveillance and maintenance (S M) of 75 sites were conductd by the Remedial Action Section for the Environmental Restoration Program for surplus facilities and sites contaminated with radioactive materials and/or hazardous chemicals. S M activities on these sites were conducted from the end of their operating life until final facility disposal or site stabilization. The objectives of the Waste Area Grouping S M Program are met by maintaining a program of routine S M as well as by implementing interim corrective maintenance when deemed necessary as a result of site surveillance. This report briefly presents this program's activities and includes tables indicating tank levels and dry well data for FY 1991.

1991-12-01

409

Surface-loss power calculations for the LANSCE DTL  

Energy Technology Data Exchange (ETDEWEB)

The surface losses in the drift-tube linac (DTL) tanks 3 and 4 of the LANSCE linear accelerator are calculated using 3-D electromagnetic modeling with the CST MicroWave Studio (MWS). The results are used to provide more realistic power estimates for the 201.25MHz RF upgrade design within the LANSCE-R project. We compared 3-D MWS results with those from traditional 2-D Superfish computations for DTL cells and their simplified models and found differences on the level of a few percent. The differences are traced to a 3-D effect consisting in a redistribution of the surface currents on the drift tubes (DT) produced by the DT stem. The dependence of MWS results on the mesh size used in computations is also discussed.

2008-01-01

410

Solid suspension in stirred tanks: UVP measurements and CFD simulations  

British Library Electronic Table of Contents (United Kingdom)

Abstract Suspension of solids in stirred reactor is widely used for catalytic reactions, dissolution, etc. Quality of solid suspension is an important parameter required for the reliable design, optimum performance, and scale up of the system. Quality of suspension depends on local characteristics of solid velocity and hold up profiles. The present work was focused on investigating quality of solid suspension using ultrasound velocity profiler (UVP) measurements and CFD simulations. The slip velocity measurements carried out with UVP were used to evaluate different drag correlations used in CFD simulations. Results discussed in this work would be useful for extending the applications of CFD models for simulating large stirred slurry reactors.

2011-01-01

411

Solar distillation as an appropriate technology tool in Haiti  

Energy Technology Data Exchange (ETDEWEB)

Source Philippe (on the island of La Govave, near Haiti) is described in terms of climatic, sociological, agricultural and technical background. Because of drought conditions, it became necessary to develop a solar still to provide the town with sufficient fresh water. The still, which has been in operation since 1969, is described in some detail as is the construction process. Brackish and sea water are used to produce more than 1250 liters of fresh water each day. A windmill is used to pump the brackish water from a well to an elevated storage tank; it flows by gravity to solar still basins where it is vaporized, then condensed on a sloping glass surface and collected. Benefits of the solar still to the town's economy and health are discussed. Cost of the project was $17,000. 10 references. (MJJ)

1980-06-01

412

Simulation and design of membrane plants with AspenPlus  

Energy Technology Data Exchange (ETDEWEB)

In this paper the simulation of hybrid processes containing membrane units will be discussed. For this purpose a user-defined module for simulation and design of membrane processes was implemented into the simulation program AspenPlus. The advantages can be summarized as follows: - any combination of membrane processes with all other units already implemented in AspenPlus is possible, including internal recycle streams, - utilization of the physical property models and data bases of AspenPlus is possible, - cost and sensitivity analysis can be performed. These benefits are demonstrated in detail for a membrane vapor recovery unit for the treatment of tank farm off-gas, for a two-stage reverse osmosis plant for organic/-organic separations and for a combination of distillation and pervaporation for the separation of a dimethylcarbonate/methanol mixture. (orig.)

1996-10-01

413

Silver removal process development for the MEO cleanout  

Energy Technology Data Exchange (ETDEWEB)

The Mediated Electrochemical Oxidation (MEO) system is an aqueous process which treats low-level mixed wastes by oxidizing the organic components of he waste into carbon dioxide and water. As MEO system continues to run, dissolved ash and radionuclides slowly accumulate in the anolyte and must be removed to maintain process efficiency. At such time, all of the anolyte is pumped into a still feed tank, and the silver ions need to be removed before sending the solution to a thin-film evaporator for further concentration. The efficiency of removing silver ions in the solution needs to be high enough such that the residual silver sent to Final Forms would be less than 1% wt. The purpose of this work is to develop an efficient process to remove silver ions during the MEO cleanout and to demonstrate the capability of centrifugation for separating small silver chloride particles from the solution. This development work includes lab scale experiments and bench scale tests. ...

1996-02-01

414

Preconceptual study of an advanced MAPLE research reactor  

International Nuclear Information System (INIS)

The Advanced MAPLE is a research reactor design under development as a high-flux neutron source. The main performance goals for the reactor are a high peak thermal neutron flux in a heavy-water reflector tank, and a high average fast neutron flux in a central irradiation facility, with a maximum linear fuel rod rating of less than 120 kW/m. This study investigated the neutronic and reactor design consequences of the use of H_2O coolant as opposed to D_2O. The neutronics results, and several other considerations, indicate that H_2O coolant has a number of advantages. It is suggested that the H_2O coolant option be considered in the design of the Advanced MAPLE reactor. (L.L.) 9 refs., 4 figs., tab.

1990-06-03

415

Oil-tanker waste-disposal practices: A review  

Energy Technology Data Exchange (ETDEWEB)

In the spring of 1991, the Environmental Protection Agency, Region 10 (EPA), launched an investigation into tanker waste disposal practices for vessels discharging ballast water at the Alyeska Pipeline Services Company's Ballast Water Treatment (BWT) facility and marine terminal in Valdez, Alaska. It had been alleged that the Exxon Shipping Company was transferring 'toxic wastes originating in California' to Valdez. In response, EPA decided to examine all waste streams generated on board and determine what the fate of these wastes were in addition to investigating the Exxon specific charges. An extensive Information Request was generated and sent to the shipping companies that operate vessels transporting Alaska North Slope Crude. Findings included information on cargo and fuel tank washings, cleaning agents, and engine room waste.

1992-01-01

416

Oak Ridge Research Reactor. Quarterly report, July, August, and September 1984  

Energy Technology Data Exchange (ETDEWEB)

The ORR operated at an average power level of 29.7 MW for 85.3% of the time during this period. The reactor was shut down on fifteen occasions, nine of which were unscheduled. Reactor downtime needed for refueling and checks was normal. The reactor remained available for operation 88.3% of the time. Special tests completed during the quarter included: (1) transfer of LEU fuel elements CLE-202 and NLE-201 from core positions B-9 and B-2 to core positions C-5 and C-6 for continued operation; and (2) calculation of maximum heat flux in LEU elements CLE-201 and NLE-202 in core positions A-2 and A-8. In-service inspections included inspections of ORR decay tank, primary heat exchanger No. 4, and the 24-in. strainer.

1985-03-01

417

Monte Carlo methods, models, and applications for the Advanced Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional, continuous-energy, coupled neutron-gamma Monte Carlo model of the advanced neutron source (ANS) final preconceptual reference core design has been developed using MCNP Version 3b. This model contains the reactor core with control rods, the heavy-water reflector tank with shutdown rods and representative beam tubes, and the outer light-water poor. Eighty homogenized fuel zones per fuel element are used to represent the radical and axial {sup 235}U fuel grading. This model is the most sophisticated, physically accurate reactor physics model of the ANS currently available. The purpose of this summary is to demonstrate the MCNP methods and applications for the ANS.

1990-06-01

418

Monosodium titanate particle characterization  

Energy Technology Data Exchange (ETDEWEB)

A characterization study was performed on monosodium titanate (MST) particles to determine the effect of high shear forces expected from the In-Tank Precipitation (ITP) process pumps on the particle size distribution. The particles were characterized using particle size analysis and scanning electron microscopy (SEM). No significant changes in particle size distributions were observed between as-received MST and after 2--4 hours of shearing. Both as-received and sheared MST particles contained a large percentage of porosity with pore sizes on the order of 500 to 2,000 Angstroms. Because of the large percentage of porosity, the overall surface area of the MST is dominated by the internal surfaces. The uranium and plutonium species present in the waste solution will have access to both interior and exterior surfaces. Therefore, uranium and plutonium loading should not be a strong function of MST particle size.

1993-01-12

419

Measuring the scale of segregation in mixing data  

British Library Electronic Table of Contents (United Kingdom)

Abstract Four methods were used to extract length scales from mixing data: the maximum striation thickness, point-to-nearest-neighbour (PNN) distributions, the correlogram and the variogram. Four test data sets were analysed: blending in a micromixer; particle dispersion in a stirred tank; dispersion of a smoke plume and a pulse tracer test in a reactor. The maximum striation thickness captures the largest length scale. The PNN method quantifies differences between clustered, random and regular spatial distributions. The correlogram calculation cannot be consistently used for all types of mixing data and has therefore been rejected. The variogram reveals both large-scale segregation and periodicity. Sub-sampling is needed to isolate smaller structures. The variogram, PNN and transect metho...

2011-01-01

420

High pressure in situ diffraction studies of metal-hydrogen systems  

British Library Electronic Table of Contents (United Kingdom)

''Hybrid'' hydrogen storage, where hydrogen is stored in both the solid material and as a high pressure gas in the void volume of the tank can improve overall system efficiency by up to 50% compared to either compressed hydrogen or solid materials alone. Thermodynamically, high equilibrium hydrogen pressures in metal-hydrogen systems correspond to low enthalpies of hydrogen absorption-desorption. This decreases the calorimetric effects of the hydride formation-decomposition processes which can assist in achieving high rates of heat exchange during hydrogen loading-removing the bottleneck in achieving low charging times and improving overall hydrogen storage efficiency of large hydrogen stores. Two systems with hydrogenation enthalpies close to -20kJ/mol H2 were studied to investigate the h...

2011-01-01

421

Geology, physical properties, and surface effects at Discus Thrower Site, Yucca Flat, Nevada Test Site  

International Nuclear Information System (INIS)

Geologic studies in connection with Project Discus Thrower have furnished detailed stratigraphic and structural information about northwestern Yucca Flat, Nevada Test Site. The Paleozoic rocks consist of a lower carbonate sequence, argillite of the Eleana Formation, and an upper carbonate sequence. The distribution of these rocks suggests that both top and bottom of the Eleana are structural contacts, probably thrusts or reverse faults. The overlying tuff includes several units recognized in the subsurface, such as the Fraction Tuff and tuff of Redrock Valley. Other units recognized include bedded tuff associated with the Grouse Canyon Member of Belted Range Tuff, and the Rainier Mesa and Ammonia Tanks Members of the Timber Mountain Tuff. The Timber Mountain and Grouse Canyon are extensively altered to montmorillonite (a swelling clay), possibly as a result of ponding of alkaline water. The overlying alluvium locally contains at the base a clayey, tuffaceous ...

422

Ford's CNG vehicle research  

Energy Technology Data Exchange (ETDEWEB)

Several natural gas vehicles have been built as part of Ford's Alternative Fuel Demonstration Fleet. Two basic methods, compressed gas (CNG), and liquified gas (LNG) were used. Heat transfer danger and the expense and special training needed for LNG refueling are cited. CNG in a dual-fuel engine was demonstrated first. The overall results were unsatisfactory. A single fuel LNG vehicle was then demonstrated. Four other demonstrations, testing different tank weights and engine sizes, lead to the conclusion that single fuel vehicles optimized for CNG use provide better fuel efficiency than dual-fuel vehicles. Lack of public refueling stations confines use to fleet operations.

1983-06-01

423

Flooding characteristics of gas-liquid two-phase flow in a horizontal U bend pipe  

International Nuclear Information System (INIS)

To evaluate safety of horizontal steam generator used in passive safety system, it is needed to make clear flooding characteristics in U bend pipe. In this study, two-phase flow experiment in a horizontal U bend pipe was carried out to make clear the influence of the length of horizontal pipe and the radius of U bend. Flooding in the U bend pipe was observed in the condition of lower gas or liquid volumetric flux than that in the horizontal pipe or the vertical pipe. Flooding and carry-up in the U bend pipe is hardly change with increasing the length between the water inlet and the U bend, but greatly related with the length from the water inlet to the lower tank and the shape of the U bend inlet. (author).

1994-05-01

424

FY 1974 NPS independent development program  

Science.gov (United States)

Thirteen summaries of exploratory development work carried out under a grant to the Naval Postgraduate School Research Foundation are included. This research was carried out in the areas of electrical engineering (slot lines; phase lock loops), aeronautics (aircraft survivability; composite materials for structures), material sciences (relation between high temperature compressive behavior and microstructure), mechanical engineering (fatigue life of ferrocement hull structures; flow fields), economics (hazardous employment incentives for DoD personnel), operations research (missile allocation modeling; combat dynamics; shipboard tank designs), oceanography breakwater construction effects on ecology), and physics (evaluation of an underwater acoustic parametric source).

1975-07-01

425

Experimental assessment of energy storage via variable speed compressor  

British Library Electronic Table of Contents (United Kingdom)

In this study, usage of a variable speed refrigeration system in latent heat thermal energy storage (LHTES) system is investigated to increase energy storage efficiency. Four different compressor speed control cases are compared to obtain a constant heat transfer fluid (HTF) temperature at the inlet of the energy storage tank. These control cases are (i) control with evaporation temperature, (ii) control with ethylene glycol temperature at the outlet section of evaporator, (iii) control with suction pressure of the compressor and (iv) on/off control. By means of the experimental analysis the best control strategy is obtained as control with Case (ii), in terms of stability of inlet temperature of heat transfer fluid, variations of energy efficiency of LHTES and coefficient of performance (...

2011-01-01

426

Design and performance of a 100-kg/h, direct calcine-fed electric-melter system for nuclear-waste vitrification  

Energy Technology Data Exchange (ETDEWEB)

This report describes the physical characteristics of a ceramic-lined, joule-heated glass melter that is directly connected to the discharge of a spray calciner and is currently being used to study the vitrification of simulated nuclear-waste slurries. Melter performance characteristics and subsequent design improvements are described. The melter contains 0.24 m/sup 3/ of glass with a glass surface area of 0.76 m/sup 2/, and is heated by the flow of an alternating current (ranging from 600 to 1200 amps) between two Inconel-690 slab-type electrodes immersed in the glass at either end of the melter tank. The melter was maintained at operating temperature (900 to 1260/sup 0/C) for 15 months, and produced 62,000 kg of glass. The maximum sustained operating period was 122 h, during which glass was produced at the rate of 70 kg/h.

1980-11-01

427

Control of linear accelerator noise in the Los Alamos free-electron laser (FEL)  

International Nuclear Information System (INIS)

FELs require tight control of the amplitudes and phase of the fields in two linear accelerator tanks to obtain stable lasing. The accelerator control loops must establish constant, stable, repeatable amplitudes and phases of the rf fields and must have excellent bandwidth to control high-frequency noise components. A model of the feedback loops has been developed that agrees well with measurements and allows easy substitution of components and circuits, thus reducing breadboarding requirements. The model permits both frequency and time-domain analysis. The accelerator control scheme and model are described and the control of noise in feedback loops is discussed, showing how low-frequency-noise components (errors) can be corrected, but high-frequency-noise components (errors) are actually amplified by the feedback circuit. Measurements of noise in both open- and closed-loop modes is shown and comparison is made with results from the model calculations.

1986-09-01

428

Contamination and restoration of groundwater aquifers  

Energy Technology Data Exchange (ETDEWEB)

Humans are exposed to chemicals in contaminated groundwaters that are used as sources of drinking water. Chemicals contaminate groundwater resources as a result of waste disposal methods for toxic chemicals, overuse of agricultural chemicals, and leakage of chemicals into the subsurface from buried tanks used to hold fluid chemicals and fuels. In the process, both the solid portions of the subsurface and the groundwaters that flow through these porous structures have become contaminated. Restoring these aquifers and minimizing human exposure to the parent chemicals and their degradation products will require the identification of suitable biomarkers of human exposure; better understandings of how exposure can be related to disease outcome; better understandings of mechanisms of transport of pollutants in the heterogeneous structures of the subsurface; and field testing and evaluation of methods proposed to restore and cleanup contaminated aquifers. In this review, ...

1993-04-01

429

Advanced resin cleaning system  

International Nuclear Information System (INIS)

Novel and unprecedented ion exchange resin cleaning system, for use in BWR plants and featuring a vibration separator and basic design factors of Radiological Solutions, Inc., had been delivered to Tokai No. 2 Power Station, Japan Atomic Power Company, in October 2005. This compactly-designed system effectively separates crud and resin fines from ion exchange resins, with no clogging of separation screens. It generates minimized waste liquid and has a specially designed over-pack cleaning tank. The system has been in operation for about 2 years and half now and favorable operational data, such as crud and sulfate concentration decrease in feed water and reactor water respectively, and evaluation results have been reported from Japan Atomic Power Company and so on. (author)

2008-07-01

430

Adsorption rate of phenol from aqueous solution onto organobentonite: Surface diffusion and kinetic models.  

Science.gov (United States)

The concentration decay curves for the adsorption of phenol on organobentonite were obtained in an agitated tank batch adsorber. The experimental adsorption rate data were interpreted with diffusional models as well as first-order, second-order and Langmuir kinetic models. The surface diffusion model adjusted the data quite well, revealing that the overall rate of adsorption was controlled by surface diffusion. Furthermore, the surface diffusion coefficient increased raising the mass of phenol adsorbed at equilibrium and was independent of the particle diameter in the range 0.042-0.0126cm. It was demonstrated that the overall rate of adsorption was essentially not affected by the external mass transfer. The second-order and the Langmuir kinetic models fitted the experimental data quite well; however, the kinetic constants of both models varied without any physical meaning while increasing the particle size and the mass of phenol adsorbed at equilibrium. ...

2011-08-22

431

Absorption of carbon dioxide at high partial pressures in 1-amino-2-propanol aqueous solution. Considerations of thermal effects  

Energy Technology Data Exchange (ETDEWEB)

In the present work, the process of carbon dioxide absorption is analyzed at high partial pressures, in aqueous solutions of 1-amino-2-propanol (monoisopropanolamine (MIPA)), in relation to the thermal effects involved. All experiments were made in a stirred-tank reactor with a plane unbroken gas-liquid interface. The variables considered were the MIPA concentration within the range 0.1--2.0 M and the temperature within the interval 288--308 K. From the results, the authors deduce that the absorption process takes place in the nonisothermal instantaneous regime and propose an equation which not only relates the experimental results of flow density with the initial concentration of amine but at the same time enables the evaluation of the rise in temperature in the gas-liquid interface.

1997-10-01

432

A Study on A Semi-Submersible Floating Offshore Wind Energy Conversion System  

Energy Technology Data Exchange (ETDEWEB)

A new semi-submersible floating structure is proposed on which three wind turbine towers are installed. This paper presents a basic characteristic of the wave-induced motion of this semi-submersible floating structure via. numerical computations and 1/150 scaled rigid model experiments in a wave tank. In the numerical computations, nonlinear damping effect due to drag forces modeled by the Morison's formula is considered in the equation of motion, where the linear hydrodynamic forces are obtained from the Green's function model. As a result, the response characteristics around the resonant frequency region were successfully improved. In addition to such basic examination, major results of feasibility studies, including the structural stability for severe wave conditions and the long-term fatigue limit state, are presented for a realistic situation.

2007-07-01

433

[Legionella pneumonia caused by aspiration of hot spring water after sarin exposure].  

Science.gov (United States)

A 72-year-old man was exposed to the sarin gas attack in a Tokyo subway on March 20 th, 1995. After exposure, he noticed eye discomfort, chest tightness, headache and weakness of the lower limbs and oropharyngeal muscles. Despite these symptoms, he visited a hot spring on the same day with his family. On March 25 th, his muscle weakness progressed, and a low grade fever appeared. His muscle weakness disappeared 8 days after exposure to sarin, but respiratory failure rapidly developed, necessitating artificial ventilation within four day after hospitalization on March 28th. Chemotherapy with erythromycin, imipenem/cilastatin, and steroid pulse therapy was begu. PCR and culture of sputum collected by bronchofiberscopy were positive for Legionella pneumophila, serogroup I. His respiratory state improved, but subsequent infection with Pseudomonous aeruginosa. Enterobacter cloacae, and Candida tropicalis/glabrata caused his death 71 days after admission. Oropharyngeal ...

1998-03-01

434

Utilisation of an Air-conditioning System to Control the Levels of Radon and Radon Progeny in a Workplace Environment  

Energy Technology Data Exchange (ETDEWEB)

From long-term real-time radon and radon progeny measurements taken in a relatively large retail store, cyclical patterns were evident, which were found to relate to the overriding influence of the timed air-conditioning system. Concentration of radon, radon progeny and the variability of F factor were found to depend significantly on the intermittent operation of this ventilation-air-conditioning system. After pressure equalisation remedial measures proved ineffective, the air-movement system was utilised to reduce the levels of radon and radon progeny to well within established norms applicable during working hours. It is demonstrated that the average levels for radon and radon progeny are reduced in absolute terms. This amounted to less than 12% of the general level, during designated work periods. Where air movement systems are already installed, as well as other circumstances, their regulation provides an economical solution to meeting legal and other ...

2000-07-01

435

The cooperative housing society Vaarst Vestervang - green building; Andelsboligforeningen Vaarst Vestervang - groent byggeri  

Energy Technology Data Exchange (ETDEWEB)

Vaarst Vestervang (Denmark) comprises 16 villas and 1 communal building. The complex was designed by the inhabitants themselves with the aim of polluting the environment as little as possible. The land area constitutes 69.000 square meters where it is possible to grass animals. The document reports a measuring programme concerning the overall heat consumption as one of the main aims of the inhabitants is to save energy and thus contribute to the protection of the environment. The capacity of the solar collectors predominantly used in the building complex was 235 kWh/m{sup 2}. Supplementary heating is provided by boilers fired with wood. The measuring system is described in detail. Tables show the influence of heat transmission losses, ventilation, airing out of rooms, the angle of the sun`s rays within the buildings and heating needs on energy consumption. Energy consumption data is presented in relation to the forms of space and water heating utilized. Daily ...

1993-10-01

436

The ''passivhaus'' standard: from energy efficiency to 'green' building; Le standard ''passivhaus'': de la performance energetique a la construction ''verte''  

Energy Technology Data Exchange (ETDEWEB)

The German voluntary standard 'Passivhaus' (passive house) leads to buildings with practically no energy consumption. The first residential buildings of this type were built in 1998 and the first tertiary buildings in 2000. Such a passive house must fulfill 5 efficiency criteria: annual space heating needs {<=} 15 kWh/m{sup 2}, U{sub v} envelope coefficient lower than 0.15 W/(m{sup 2}.K), U{sub v} of openings lower than 0.8 W/(m{sup 2}.K), airtightness {<=} 0.6 volume/hour, and total energy needs (space heating, hot water, ventilation, lighting and domestic uses) measured at the meter lower than 42 kWh/m{sup 2}.year. This article makes a status of the effective efficiency of existing passive buildings both in the residential and tertiary sectors and presents some possible ways of improvement. (J.S.)

2005-10-01

437

Series fan-powered boxes: Their impact on indoor air quality and comfort  

Energy Technology Data Exchange (ETDEWEB)

Until the concerns about indoor air quality (IAQ) reached a peak in the last five years, interior zones of office buildings were traditionally served with cooling-only shut-off variable air volume (VAV) boxes. Heat gains from lighting and equipment, in addition to those from occupants themselves, caused supply air quantities of 13 C to 15 C (55 F to 60 F) air to be sustained at rates on the order of 2.5 L/s per square meter (0.5 cfm per square feet), a rate that most designers at the time felt would provide a comfortable and well ventilated environment. More recently, the reduction in lighting loads, the use of cold air systems, and, most importantly, the concern that acceptable indoor air quality may not be maintained at low air flow rates, has led to a different solution in interior zones: the series fan-powered mixing box.

1996-07-01

438

Reducing indoor air formaldehyde concentrations  

Energy Technology Data Exchange (ETDEWEB)

Urea-formaldehyde resin bonded particle board, medium density fiberboard and plywood paneling are used as flooring, wall paneling, for cabinet work and in furniture, and are present in almost every office, home and public building. If large quantities of these products are used in poorly ventilated spaces, high manufacturing quality control is necessary to avoid problems of latent formaldehyde release. Indoor air formaldehyde concentrations depend on the nature of the product, the product surface to air volume (loading) factor, temperature, humidity, age and product emission rates. Standard test methods are now available for measuring product emission rates that make it possible to predict the performance of UF-bonded pressed wood materials if use conditions and environmental parameters are known. Recent modifications in adhesive and board manufacturing parameters have made it possible to reduce formaldehyde emission significantly, and UF-bonded wood products are ...

1985-08-01

439

Radon concentration measurements in the desert caves of Saudi Arabia  

Energy Technology Data Exchange (ETDEWEB)

Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm{sup -3}. The average radon concentration in four of the caves was low in the range 74-114Bqm{sup -3}. However, one cave showed an average radon concentration of 451Bqm{sup -3}. Radon is not a problem for tourists in the ...

2005-11-15

440

Radon concentration measurements in the desert caves of Saudi Arabia  

International Nuclear Information System (INIS)

Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm"-"3. The average radon concentration in four of the caves was low in the range 74-114Bqm"-"3. However, one cave showed an average radon concentration of 451Bqm"-"3. Radon is not a problem for tourists in the majority of ...

2005-11-01

441

Predictions of benefits and costs derived from improving indoor air quality in telephone switching offices  

Energy Technology Data Exchange (ETDEWEB)

Airborne pollutants can cause failures in switching and computing equipment. This paper focuses on a subset of such pollutants - airborne fine particles (<2.5 [mu]m diameter). It begins by examining the extent to which different improvements in heating, ventilating and air conditioning (HVAC) systems reduce indoor concentrations of fine particles. For each modification, the consequent reduction in soiling rate is derived. The concomitant increase in operating costs is also calculated. These costs are then compared with the costs of failures in telephone switching offices, leading to estimates of failure rate reductions that would make improvements cost-effective. Finally, the reduction in failures required to offset the costs of the improvements are compared with documented differences in failure rates between unimproved and improved environments. This study suggests that, in many telephone switching offices, the added operating costs associated with more ...

1991-01-01

442

Overview of Chuetsu-oki earthquake and evaluation of seismic safety  

International Nuclear Information System (INIS)

The Chuetsu-oki Earthquake strongly shook the Kashiwazaki-Kariwa Nuclear Power Station with the ground motions exceeding the design values. The incidents include a fire breakout of the Unit 3 transformer, a release of spilled water containing small amount of radioactive materials to the non-radiation control area and subsequently to the environment at Unit 6, and a release of radioactive material from the main turbine condenser through the main stack of Unit 7 due to the delay stooping the turbine gland steam ventilator by the operator in manually, while every unit in operation was safety shutdown in the automatic mode ensuring the three fundamental safety functions of (a) reactivity control, (b) removal of heat from the core and (c) confinement of radioactive materials. Following integrity evaluation and performance testing of the overall plant, seismic safety of buildings, structures, equipment and pipelines on the basis of the basic earthquake ground motion Ss ...

2010-07-01

443

In-depth survey report of Early and Daniel Co. , Inc. , Louisville, Kentucky  

Science.gov (United States)

An in-depth industrial hygiene survey was conducted to evaluate worker exposures to phosphine during fumigation of grain at the Early and Daniel Co. grain elevator in Louisville, Kentucky. Stored grain was fumigated using aluminum phosphide. Aluminum-phosphide pellets were also added directly to the grain by the blender as it was poured into the storage containers. Local exhaust ventilation was used at points in the grain-moving system where grain dust was generated. Air samples were taken during full-shift periods at the breathing zone of the weighmaster, two bin floormen, and the blender. Area monitoring samples were also taken. If the operators spend considerable time in the vicinity of a bin which is being filled with grain, there is a likelihood of far greater exposure levels being noted. According to the author, further studies of the use of phosphide products at other elevators should be conducted to determine the effect of environmental and process ...

1986-09-01

444

Guidelines for indoor air hygiene in school buildings  

Energy Technology Data Exchange (ETDEWEB)

The new guidelines for indoor air hygiene in school buildings are intended as a response to current requirements in school practice. The recommendations aim to help to avoid mistakes in modernising school buildings and to provide hygiene-specific support in planning of new school buildings. The guidelines are laid out as follows: (a) In the general section the targets of the guidelines and the target groups are addressed. The current indoor hygiene situation in German schools is described, followed by the parameters with regard to peripheral issues which will not be dealt with further; (b) Part A deals with the hygiene requirements in the practical running of schools. Besides general requirements for maintenance and operation the important issues of cleaning and ventilation are considered, as well as minor building works; (c) Part B provides an overview of important chemical and biological contaminants in schools; (d) Part C looks at building and air conditioning ...

2008-08-15

445

Development of advanced residential cooktop burner with low NOx emissions. Annual report on phase 1, Feb 82-Oct 83  

Science.gov (United States)

This report describes the result of work completed during February, 1982 to October 1983. The aim of the work was to develop a low NO(x) emission range top burner. Discussed is the development of a flame insert modification to an existing burner which reduces NO(x) emission by 45 percent and NO2 emission by 25 percent. This relatively simple burner add-on device appears to be an economically viable low NO(x) burner. It was developed in cooperation with a major range manufacturer. The levels of NO(x) (NO2) reduction achieved should significantly reduce the impact of a gas range to indoor quality. The report also discusses the results of a literature search that preceeded the burner development. The search helped to direct the burner development by reviewing the state-of-the-art of low NO(x) burner design and covered factors which affect the indoor impact of range emissions such as air infiltration and ventilation trends, air quality standards, and NO(x) (NO2) health ...

1983-11-01

446

Development of advanced residential cooktop burner with low NO/sub x/ emissions. Annual report Feb 82-Jan 83  

Science.gov (United States)

This report describes the results of work conducted during February 1982 - January 1983. A literature search was initiated to identify the state-of-the-art of NOx (NO + NO/sub 2/) reduction technologies, including NOx measurement methodologies, air infiltration and ventilation trends, the impact of NOx (NO/sub 2/) emissions on health, and air quality standards. As a result of the literature search NOx (NO/sub 2/) reduction goals were established for the project and technologies to achieve these goals identified. This report also covers the development of a prototype burner which examined flue gas recirculation, burner designs, secondary air baffling and flame inserts as potential technologies to reduce NOx (NO/sub 2/). Because of their potential for NOx (NO/sub 2/) reduction shown by initial experiments, an in-depth analysis of ring insert configurations was conducted. These results, along with other technological experiments, are presented in this report.

1983-02-28

447

Detailed industrial hygiene survey, formaldehyde production, E. I. DuPont de Nemours and Co. , Chemicals and Pigment Department, Grasselli Plant, Linden, New Jersey  

Energy Technology Data Exchange (ETDEWEB)

A survey to assess the techniques used to control occupational exposure to formaldehyde (50000) and methanol (67561) was conducted at the E. I. DuPont de Nemours and Company (SIC-2869) formaldehyde production unit, Linden, New Jersey, in October 1982. Exposure concentrations were reduced primarily by the use of a process that was completely enclosed except for process sampling, methanol unloading, and formaldehyde discharge points. Local and area exhaust ventilation, and work practices were also used to control exposures. Formaldehyde concentrations in the absorber area were controlled by burning the exit gases in an afterburner and discharging them high above the ground. Analysis of area and breathing zone samples showed methanol and formaldehyde concentrations below the OSHA limits of 200 and 3 parts per million, respectively. The authors conclude that workers are not overexposed to either methanol or formaldehyde on a short or long term basis. Maintenance ...

1983-09-01

448

Design and analysis of a dust extraction system  

Energy Technology Data Exchange (ETDEWEB)

A dust extraction system removes the contaminated air at source by means of a hood. The extraction system for dust is essentially a ducted air system that prevents excessive employee exposure to dust in the working zone. The four major mechanisms that remove the contaminants in an extraction system are: - capture of contaminants by hoods - transport of contaminated air in duct network - separation of dust in the collector - exhaust of clean air through stack. The current methods of design are based on empirical relations, multi-variable tables, graphs and nomographs that have been derived from the principle of fluid mechanics and particle dynamics. However, the empirical formulae, tables and graphs are used in different geographical locations of the world having different environmental conditions and geo-characteristics of dust particles. Therefore, it is required to establish a rational design method that will be based on analysis of each sub-system to achieve an efficient and cost ...

2006-07-01

449

Control of population dose equivalent from naturally occurring radionuclides in building materials  

International Nuclear Information System (INIS)

Naturally occurring radionuclides in building materials are a source of external and interal radiation exposure to essentially the entire US population. Although detailed data are not available, estimates are that the average contribution from such sources to the external dose equilvaent rate in brick and masonry houses is about 5 to 10 mrem/year. For critical population groups, values reported in the literature for the contribution from such sources range up to a hundred mrem/year or more. Dose equivalent rates to the lungs are even higher and, for abnormal situations, it would appear that control measures, either on a voluntary or mandatory (legislative) basis should be considered. Such measures include: (1) material substitution; (2) improved manufacturing standards; (3) changes in basic building designs; (4) application of surface sealants; and (5) increased ventilation accompanied by processes for the adsorption and/or filtration of airborne radionuclides. ...

450

Control of airborne particle concentration and draught risk in an operating room  

Energy Technology Data Exchange (ETDEWEB)

The influence of location of airborne particle source, ventilation rate, air inlet size, supply air velocity, air outlet location, and heat source on the distributions of airborne particle concentration and draught risk in an operating room is investigated. The investigation is carried out by using a flow program with the k-[epsilon] model of turbulence. Based on a standard case, five cases, each with one changed parameter, are computed, and the detailed field distributions of air velocity, temperature, airborne particle concentration, and draught risk are presented. The parametric study concludes that, for a better air quality and thermal comfort, it is desirable to use a higher inflow rate, a larger inlet area, and a uniform velocity profile of supply air. Outlet location and heat source have little influence on the distributions of the particle concentration in the room. It has also been found that the distributions of particle concentration in the recirculating ...

1992-01-01

451

Combustion of chemical substances. Fire characteristics and smoke gas components in large-scale experiments  

Energy Technology Data Exchange (ETDEWEB)

This report describes the combustion experiments performed using the SP Industry Calorimeter. In addition to measuring parameters such as heat release rate (HRR), mass loss rate, effective heat of combustion and smoke obscuration, considerable effort was put into the characterisation of the smoke gases in order to obtain a basis for evaluations of the toxic potency of the smoke. The materials studied were Nylon 66, polypropene, polystyrene (with and without fire retardant, respectively), PVC and chlorobenzene. A total of 19 large-scale, well ventilated combustions were carried out. The mass of sample burned ranged from 20 kg to 125 kg in an experiment. A procedure was designed for cleaning the smoke gas duct between experiments and was found to be effective. Measurements were carried out for the amounts of O{sub 2}, CO{sub 2}, CO, NO{sub x}, THC (unburned hydrocarbons), HCN, HCl, NH{sub 3} and individual organic compounds in the smoke. Adsorbents were used for the ...

1995-12-31

452

Climate analysis of the Dresden Frauenkirche; Bauklimatische Analyse der Frauenkirche in Dresden  

Energy Technology Data Exchange (ETDEWEB)

The analyses were carried out using real climate data for the years 1987 and 1989. The course of the indoor climate for year-round free ventilation with a constant flow volume is discussed. Numerous diagrams inform on ambient temperature, water vapour content, the condition of space air, and temperature drops below dew point. For the event of heating of the central part of the church, space air condition, the annual air humidification requirement, and the temperature field in this part of the building are described. (MSK) [Deutsch] Die Untersuchungen wurden mit aktuellen Klimadaten fuer die Jahre 1987 und 1989 durchgefuehrt. Der Verlauf des Raumklimas bei ganzjaehrig freier Klimatisierung mit konstantem Foerderstrom wird erlaeutert. Dabei wird die Raumlufttemperatur, der Wasserdampfgehalt, der Raumluftzustand sowie die Taupunktunterschreitung in zahlreichen Diagrammen aufgezeigt. Weiter werden fuer den Fall der Beheizung des Hauptraums der Kirche der ...

1997-12-01

453

Calculation of ventilation efficiency and of load situations for load-relieving air conduction systems; Berechnung der Lueftungseffektivitaet und der Belastungssituation fuer lastmindernde Luftfuehrungen  

Energy Technology Data Exchange (ETDEWEB)

Zone modeling permits taking account of the effect of load-relieving air conduction systems in the planning of HVAC plants. Although this only supplies average values for the degree of load and height of the fresh air layer rather than a detailed description of concentration and temperature distributions in the room, it is quite sufficient for the planning of load-relieving air conduction systems. Moreover, the cost of zone modeling in the planning of HVAC plants remains within reasonable limits. Upscale planning, instruments can thus be reserved for more exacting problems. (orig.) [Deutsch] Zonenmodelle erlauben die Wirkung lastmindernder Luftfuehrungen bei der Planung von RLT-Anlagen zu beruecksichtigen. Sie liefern zwar nur Mittelwerte fuer den Belastungsgrad und die Hoehe der Zuluftschicht und keine detaillierte Konzentrations- und Temperaturverteilungen im Raum. Diese Werte reichen jedoch fuer die Planung lastmindernder Luftfuehrungskonzepte aus. Zudem ist der Aufwand fuer den ...

1994-12-31

454

CFD investigation of unstable airflow due to temperature difference via horizontal openings  

Energy Technology Data Exchange (ETDEWEB)

Air flow and the buoyancy-driven flow through a building`s horizontal openings was discussed. Horizontal openings occur in staircases, stairwells, ventilation shafts and chimneys. Mass and energy transfer through them have important implications regarding energy saving, thermal comfort, control of contaminants and micro-organisms and spread of fire and smoke. The analysis of the buoyancy-driven flow was attained using computational fluid dynamics (CFD). Use was made of the CFD code FLUENT which integrated the Navier-Stokes equations by a time-dependent, finite volume method. Good agreement was achieved between predicted and experimental measurements of flow rate. Results showed that flow patterns in horizontal openings were transient and unstable. The air exchange through the openings occurred in intermittent pulses. The flow rate through the opening increased with the temperature difference between zones in buildings and the size of the horizontal opening. 3 ...

1995-12-31

455

Aerodynamic design of the George Washington University solar car Sunforce 1  

Energy Technology Data Exchange (ETDEWEB)

Aerodynamics play a critical role in the success of a competitive solar vehicle. In particular, the topics addressed in this paper are minimizing the drag forces acting on the car surface while providing an effective angle of solar exposure, ventilation, manoeuvring stability, maintenance accessibility, and component `functional duality`, while simultaneously maintaining stringent racing regulations. Starting with a conceptual design, modifications were analysed through a commercial, computational fluid dynamics (CFD) package in order to evaluate drag and lift characteristics. By visualizing wind tunnel flow as a means of support of the coded model, the computational design has been validated. Although the design of the George Washington University (GWU) solar car `Sunforce 1` was geared towards the November 1993 World Solar Challenge held in Australia, results of the fourth place finish in the US Sunrace `93 were used to demonstrate the effectiveness of this ...

1997-05-01

456

Abrasive waterjet cutting of high purity uranium metal: Topical report  

Science.gov (United States)

The Abrasive Waterjet Cutting process was evaluated to determine if the equivalent could be utilized for cutting uranium metal at the Feed Materials Production Center (FMPC). In the process, a thin stream of ultrahigh pressure water carried grit material through a designated piecepart. In order to be acceptable for use at the FMPC, the equipment must be cost effective, minimize waste, and be adaptableto operating in an enclosure, and improve health and safety conditions. Observation of the cutting process showed that health and safety aspects could be optimized with an enclosed ventilated system. Also the equipment can be easily automated. The cutting action produced sparks similar to the sparks caused by a grinding operation. The sparks are captured in a water container under the workpiece that not only catches the sparks, but also serves to dissipiate the stream of water and residues produced by the cut. Metallographic tests performed on the cut surface of the ...

1988-01-01

457

A healthy climate for the Printer house. Indoor climate improved by means of adjucting the air conditioning installation; Een gezond klimaat voor het Printerhuis. Binnenklimaat verbetert dankzij aanpassing LBK  

Energy Technology Data Exchange (ETDEWEB)

In the first part of the nineties many office buildings were equipped with indoor climate installations which do not meet present standards. Several options are available to improve such installations for ventilation capacity, cooling capacity, thermal comfort and air quality. One of the options concern the installation of an air conditioner in combination with heat recovery. In this article attention is paid to the renovation of the air conditioning system in the Printer house, an office building in Zwolle, Netherlands. [Dutch] Begin jaren negentig zijn veel kantoorpanden gebouwd waarvan de klimaatinstallatie tegenwoordig niet meer voldoet. De ventilatiecapaciteit is ontoereikend en koeling is mondjesmaat aanwezig, of slechts als topkoeling. Het comfort en de luchtkwaliteit zijn dan ook onder de maat. Er zijn verschillende mogelijkheden om dit te verbeteren. Plaatsing van een nieuwe luchtbehandelingskast met warmteterugwinning is daar een van. In dit artikel wordt ...

2007-05-15

458

Ozone removal by green building materials  

Energy Technology Data Exchange (ETDEWEB)

Interest in finding out passive ways to keep the variation in the indoor climate within the comfort zone is gaining in popularity. One possible solution is the use of the moisture-buffering property of materials. In this study, the effects of the ventilation system and moisture-buffering properties of the building fabric on the stability of the indoor temperature and humidity are analysed by means of long-term field measurements. Indoor climate measurements were carried out in 170 detached houses (248 rooms). Temperature and relative humidity were measured continuously in bedrooms and living rooms at one-hour intervals over a one-year period. In general, it may be concluded that in this study, the ventilation had a greater effect on the indoor climate than the properties of the building fabric. The dampening effect of hygroscopic materials was remarkably less in the field measurements than it was in simulations in different studies. This ...

2009-08-15

459

Indoor radon concentration measurements in Tarqumia Girl Schools at Western Hebron Region, Palestine  

International Nuclear Information System (INIS)

In this study, radon-222 in indoor air was surveyed in 62 rooms located in four governmental schools, for girls, in Tarqumia town that lies in the north western part of Hebron city in Palestine. The annual effective dose equivalents resulting from the inhalation of radon and its daughters by 2318 pupils and 102 staff members occupying the surveyed rooms were also measured. TASTRAK, a solid state nuclear track detector, has been used to measure the indoor radon concentrations at those schools thus, 124 radon detectors were distributed in the four school buildings. The radon detectors stayed for 70 days between February 2006 and April 2006. The results showed that the radon concentration and the annual effective dose equivalent in these schools were varied from 12 to 232.5 Bq/m"3 with an average of 34.1 Bq/m"3 and 0.62 to 12.0 mSv/y with an average of 1.76 mSv/y, respectively. The mean values of radon concentrations in Tarqumia secondary girls school, Al-aqsa elementary girls school, ...

460

FDS3 simulations of indoor hydrocarbon fires engulfing radioactive waste packages  

International Nuclear Information System (INIS)

The thermal environment of a hypothetical large indoor hydrocarbon pool fire is more complex compared to outdoor fires and can be more severe for engulfed objects. In order to analyze potential thermal environments for interim storage of spent fuel casks or low-level radioactive waste packages engulfed in pool fires numerical simulations with the CFD fire code FDS3 were carried out for different storage configurations. In addition, data of indoor pool fire experiments were used to validate the model for this type of application. A series of pool fire experiments under different ventilation conditions and varied pool surface (1 m"2 - 4 m"2) inside a compartment of 3.6 m x 3.6 m x 5.7 m was conducted at iBMB (Institut fuer Baustoffe, Massivbau und Brandschutz) of Braunschweig University of Technology, Germany. The instrumentation included thermocouples, heatflux and pressure gauges, bi-directional flow probes and gas concentration measurements. A mock low-level waste ...

2004-09-20

461

Tank waste remediation system retrieval and disposal mission key enabling assumptions  

Energy Technology Data Exchange (ETDEWEB)

An overall systems approach has been applied to develop action plans to support the retrieval and immobilization waste disposal mission. The review concluded that the systems and infrastructure required to support the mission are known. Required systems are either in place or plans have been developed to ensure they exist when needed. The review showed that since October 1996 a robust system engineering approach to establishing integrated Technical Baselines, work breakdown structures, tank farm structure and configurations and work scope and costs has been established itself as part of the culture within TWRS. An analysis of the programmatic, management and technical activities necessary to declare readiness to proceed with execution of the mission demonstrates that the system, people and hardware will be on line and ready to support the private contractors. The systems approach included defining the retrieval and immobilized waste disposal mission requirements ...

1998-01-05

462

Subcriticality measurements for two coupled uranyl nitrate solution tanks using /sup 252/Cf-source-driven neutron noise analysis methods  

Energy Technology Data Exchange (ETDEWEB)

The subcriticality of two interacting solution tanks was determined using /sup 252/Cf-source-driven neutron noise analysis methods. These experiments were the first test of this method for an interacting system with materials (in this case, uranyl nitrate) typical of nuclear materials in processing plants. The experiments were performed to test the conclusions from previous interaction experiments with uranium metal discs for a fissile system with moderation, and to provide data to test theoretical models for coupled systems. The uranium metal experiments showed that the subcritical neutron multiplication factor, k/sub eff/, could be determined using point kinetics without any correction for spatial effects from measurements with the source and detectors located adjacent to the same cylinder, whereas for source-detector configurations with either the source and/or detectors adjacent to different cylinders, a model which incorporates the coupling is required to ...

1986-01-01

463

Radiation testing of organic ion exchange resins  

International Nuclear Information System (INIS)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of "1"3"7Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated ...

1983-04-11

464

Radiation testing of organic ion exchange resins  

Energy Technology Data Exchange (ETDEWEB)

A number of ion exchange materials are being evaluated as part of the Tank Waste Remediation System (TWRS) Pacific Northwest Laboratory (PNL) Pretreatment Project for the removal of {sup 137}Cs from aqueous tank wastes. Two of these materials are organic resins; a phenol-formaldehyde resin (Duolite CS-100) produced by Rohm and Haas Co. (Philadelphia, Pennsylvania) and a resorcinol-formaldehyde (RF) resin produced by Boulder Scientific Co. (Mead, Colorado). One of the key parameters in the assessment of the organic based ion exchange materials is its useful lifetime in the radioactive and chemical environment that will be encountered during waste processing. The focus of the work presented in this report is the radiation stability of the CS-100 and the RF resins. The scope of the testing included one test with a sample of the CS-100 resin and testing of two batches of the RF resin (BSC-187 and BSC-210). Samples of the exchangers were irradiated ...

1995-09-01

465

Quantifying the Reactive Uptake of OH by Organic Aerosols in aContinuous Flow Stirred Tank Reactor  

Energy Technology Data Exchange (ETDEWEB)

Here we report a new method for measuring the heterogeneous chemistry of submicron organic aerosol particles using a continuous flow stirred tank reactor. This approach is designed to quantify the real time heterogeneous kinetics, using a relative rate method, under conditions of low oxidant concentration and long reaction times that more closely mimic the real atmosphere. A general analytical expression, which couples the aerosol chemistry with the flow dynamics in the chamber is developed and applied to the heterogeneous oxidation of squalane particles by hydroxyl radicals (OH) in the presence of O2. The particle phase reaction is monitored via photoionization aerosol mass spectrometry and yields a reactive uptake coefficient of 0.51+-0.10, using OH concentrations of 1-7x108 molec cdot cm-3 and reaction times of 1.5+-3 hours. This uptake coefficient is larger than that found for the reaction carried out under high OH concentrations (~;;1x1010 molec cdot cm-3) and ...

2009-03-01

466

Preliminary investigation of /sup 252/Cf-driven neutron noise analysis for subcritical fuel solution systems  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the reactivity of highly subcritical systems of fissile material, using neutron-noise power spectral densities in conjunction with a /sup 252/Cf source, had previousy been tested in two fast reactor critical assemblies (a mockup of the Fast Flux Test Facility reactor and unreflected enriched uranium metal assemblies) and one thermal reactor (a light-water moderated and reflected lattice of Oak Ridge Research Reactor fuel elements). The last-mentioned test demonstrated the effectiveness of the method in water-moderated systems and thereby prompted the present study of its application to facilities for fuel preparation, reprocessing, and storage. To investigate the applicability of this method to facilities for fuel preparation, reprocessing, and storage, limited experiments were performed with a uranyl fluoride solution. The Los Alamos National Laboratory SHEBA facility, an unreflected cylindrical tank (56 cm diam), was partially filled with ...

1981-01-01

467

Multi-day test of the caustic-side solvent extraction flowsheet for cesium removal from a simulated SRS tank waste.; TOPICAL  

International Nuclear Information System (INIS)

To demonstrate that the caustic-side solvent extraction (CSSX) process could remove cesium from Savannah River Site (SRS) high-level waste over long periods of time, an improved minicontactor (2-cm centrifugal contactor) was needed that could be operated for several days. In particular, the contractor temperature had to be controlled and contactor hydraulic performance needed to be improved. Because the process was to be continuous, provisions were made for a three-shift operation. With the improvements made and the operators trained, the CSSX process was run in a 33-stage minicontactor over a period of three days to remove cesium from an average SRS siumulant for the waste feed. The two key process goals were achieved: (1) the cesium was removed from the waste with decontamination factors greater than 40,000 and (2) the recovered cesium was concentrated by a factor of 15 in dilute nitric acid. These goals were maintained for 71 h as 1.4 L of solvent was recycled 42 times while ...

468

Field performance of a premium heating oil  

Energy Technology Data Exchange (ETDEWEB)

As part of our ongoing research to provide quality improvements to heating oil, Mobil Oil together with Santa Fuel, Inc., conducted a field trial to investigate the performance of a new premium heating oil. This premium heating oil contains an additive system designed to minimize sludge related problems in the fuel delivery system of residential home heating systems. The additive used was similar to others reported at this and earlier BNL conferences, but was further developed to enhance its performance in oil heat systems. The premium heating oil was bulk additized and delivered to a subset of the customer base. Fuel related, unscheduled service calls were monitored in this test area, as well as in a similar baseline area that did not receive the premium heating oil. Overall, the premium fuel provided a 45% reduction in the occurrence of fuel related, unscheduled service calls as compared to the baseline area. Within this population, there was a reduction of 38% in systems with 275 ...

1996-07-01

469

Federal Facility Agreement plans and schedules for liquid low-level radioactive waste tank systems at Oak Ridge National Laboratory, Oak Ridge, Tennessee  

Energy Technology Data Exchange (ETDEWEB)

The Superfund Amendments and Reauthorization Act of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) requires a Federal Facility Agreement (FFA) for federal facilities placed on the National Priorities List. The Oak Ridge Reservation was placed on that list on December 21, 1989, and the agreement was signed in November 1991 by the Department of Energy Oak Ridge Field Office (DOE-OR), the US Environmental Protection Agency (EPA)-Region IV, and the Tennessee Department of Environment and Conservation (TDEC). The effective date of the FFA was January 1, 1992. Section 9 and Appendix F of the agreement impose design and operating requirements on the Oak Ridge National Laboratory (ORNL) liquid low-level radioactive waste (LLLW) tank systems and identify several plans, schedules, and assessments that must be submitted to EPA/TDEC for review or approval. The initial issue of this document in March 1992 transmitted to EPA/TDEC those plans ...

1993-06-01

470

Estimation of source term release during SGTR sequences at Wolsong plants  

International Nuclear Information System (INIS)

Source term release characteristics are analyzed for the severe SGTR (Steam Generator Tube Rupture) sequences beyond the design basis accidents in Wolsong 2/3/4 plants which are of CANDU6 type reactor. In PWRs, SGTR sequences have long been recognized to be important and are distinctly different from the non-bypass sequences since there is a direct fission product release path from the primary system to the environment bypassing the containment gas volume. Meanwhile, a SGTR in a CANDU reactor is analyzed not to provide a complete and direct path into the environment for the source term resulting from a severe accident. This is because the majority of the fission product released arises from heatup and interactions of the disassembled fuel channel segments and debris in the calandria tank rather than from fuel heatup in the fuel channel. These fission products are released from the calandria tank into the containment atmosphere through the four ...

1998-10-21

471

Development of a dedicated ethanol ultra-low emission vehicle (ULEV) system design  

Energy Technology Data Exchange (ETDEWEB)

The objective of this 3.5 year project is to develop a commercially competitive vehicle powered by ethanol (or ethanol blend) that can meet California`s ultra-low emission vehicle (ULEV) standards and equivalent corporate average fuel economy (CAFE) energy efficiency for a light-duty passenger car application. The definition of commercially competitive is independent of fuel cost, but does include technical requirements for competitive power, performance, refueling times, vehicle range, driveability, fuel handling safety, and overall emissions performance. This report summarizes a system design study completed after six months of effort on this project. The design study resulted in recommendations for ethanol-fuel blends that shall be tested for engine low-temperature cold-start performance and other criteria. The study also describes three changes to the engine, and two other changes to the vehicle to improve low-temperature starting, efficiency, and emissions. The three engine ...

1995-02-01

472

Glass Furnace Combustion and Melting Research Facility.  

Energy Technology Data Exchange (ETDEWEB)

The need for a Combustion and Melting Research Facility focused on the solution of glass manufacturing problems common to all segments of the glass industry was given high priority in the earliest version of the Glass Industry Technology Roadmap (Eisenhauer et al., 1997). Visteon Glass Systems and, later, PPG Industries proposed to meet this requirement, in partnership with the DOE/OIT Glass Program and Sandia National Laboratories, by designing and building a research furnace equipped with state-of-the-art diagnostics in the DOE Combustion Research Facility located at the Sandia site in Livermore, CA. Input on the configuration and objectives of the facility was sought from the entire industry by a variety of routes: (1) through a survey distributed to industry leaders by GMIC, (2) by conducting an open workshop following the OIT Glass Industry Project Review in September 1999, (3) from discussions with numerous glass engineers, scientists, and executives, and (4) during visits to ...

2004-08-01

473

Theoretical simulation of SDS - 2 actuation in 540 MWe PHWR  

International Nuclear Information System (INIS)

The 540 MWe PHWR has two fully independent shutdown systems. The first shutdown system (SDS-1) comprises of 28 spring assisted, vertical gravity drop shut-off rods, each consisting of a cadmium absorber sandwiched between stainless steel tubes. The second shutdown system (SDS-2) constitutes six poison tanks connected to respective zircaloy injection tubes. This system is capable of high speed injection of gadolinium nitrate solution (in D2O) into the moderator through these tubes. Theoretical estimation was carried out at different injection pressures and different concentration of gadolinium nitrate solution to arrive at the limiting value of these parameters from reactivity consideration point of view. The plant measurements of SDS-2 actuations at 60 and 80 Kg/cm2 pressure of helium was used to validate and upgrade the estimation model. The paper gives the details of the validation details of SDS-2 actuation. (author)

2006-11-13

474

Reliability engineering in aerospace technology. Approach to the assurance of high reliability; Eisei uchu rocket no shinraisei. Koshinraisei eno torikumi  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an approach to the reliability engineering in aerospace technology. To promote development, configuration management (clarifies the base line of technology), reliability management, quality control, safety management, progress management, and cost management are very important. The following example related to reliability was contained for the development of an N-1 rocket in Japan. A timer and amplifier that are old-fashioned but have actual results were supplied from abroad. The induction system that was purchased from abroad contained faulty components in quality control. The improvement in reliability has priority and the first-stage tank was changed to a home-made aluminum alloy that is superior in stress-resistant corrosiveness. An H-II rocket was completely developed in Japan by self-technology. The number of faults to be generated in the H-II rocket decreases as compared with the N-1 rocket. In the combustion test of an H-II rocket`s ...

1995-02-05

475

RCRA closure of the Building 3001 Storage Canal  

Energy Technology Data Exchange (ETDEWEB)

The 3001 Storage Canal is located under portions of Buildings 3001 and 3019 at Oak Ridge National Laboratory (ORNL) and has a capacity of approximately 62,000 gallons of water. The term canal has historically been used to identify this structure, however, the canal is an in-ground reinforced concrete structure satisfying the regulatory definition of a tank. From 1943 through 1963, the canal in Building 3001 was designed to be an integral part of the system for handling irradiated fuel from the Oak Ridge Graphite Reactor. Because one of the main initial purposes of the reactor was to produce plutonium for the chemical processing pilot plant in Building 3019, the canal was designed to be the connecting link between the reactor and the pilot plant. During the war years, natural uranium slugs were irradiated in the reactor and then pushed out of the graphite matrix into the system of diversion plates and chutes which directed the fuel into the deep pit of the canal. ...

1992-09-01

476

Primary coolant depressurization facility  

Energy Technology Data Exchange (ETDEWEB)

In a PWR type reactor, a primary coolant circuit system using a steam generator is adopted in order to accelerate depressurization of a primary coolant circuit upon small rupture LOCA in which the pressure of the primary coolant circuit is moderately depressurized. A secondary coolant circuit depressurization valve is disposed to a main steam pipeline. The valve has a performance of automatically opening to remove heat by evaporation of water stored in SG for a short period of time when the pressure in the primary circuit is decreased to about 50kg/cm[sup 2] upon occurrence of LOCA or the like. Then, the secondary side of the SG is depressurized to about atmospheric pressure and gravitational water injection from a condensate tank is started. Further, a gas vent valve is disposed to a water chamber of the steam generator. The valve has a performance of automatically opening to discharge incondensible gas mixed to the primary coolant circuit to the outside of the ...

1992-10-14

477

Optoelectronic multipoint liquid level sensor for light petrochemical products  

Science.gov (United States)

In this article we describe an optoelectronic sensor for assessing the level of light petrochemical products in technological tanks at the oil refineries. This sensor employs the multi-element vertical array of discrete micro- optical refractometric transducers. The transducers are made of silica glass and have the conical shape. In the air, each transducer operates as a tiny retro-reflector that optically couple together two multimode optical fibers. The optical coupling in the transducer is due to the internal reflection at the conical surface. The amount of the coupling depends on the refractive index of the surrounding media. In a fluid, the total internal reflection vanishes and the coupling becomes negligibly small. The number of immersed transducers is a measure of the fluid level in the reservoir. Because of the significance of the transducer transmission function, it is evaluated in detail under various combinations of the geometrical parameters of the ...

2000-06-01

478

Oil coastal tanker maintenance and availability  

Energy Technology Data Exchange (ETDEWEB)

ANCAP (Government's Oil Company of Uruguay) owns a 4000 DWT oil coastal tanker which is mainly used for oil transport in the River Plate, Uruguay and Parana rivers. Availability of the ship is critical because of shortage of available vessels in the region. Full maximum draught of the vessel is 4m , so it can navigate in very shallow waters as it is the case of some places in the Uruguay and Parana rivers. Although the ship was built in 1979, it is a complete double hull, powered by two twin main engines and propellers. Since 1994, several changes in maintenance management have been introduced, in order to increase the availability, thus increasing the total oil volume yearly transported. These changes affected several maintenance items and they also included a modification in the design of part of the cargo tank floors of the ship. As a result of these changes, an increase of 60% of the oil derivatives volume transported yearly was achieved. In this ...

2008-07-01

479

Models comparative study for heat storage in fixed beds; Estudo comparativo de modelos para armazenamento de calor em leitos fixos  

Energy Technology Data Exchange (ETDEWEB)

This work presents comparative results of a numerical investigation of four possible models for the prediction of thermal performance of fixed bed storage units and their thermal design. These models includes Schumann's model, the radial dispersion model, a model that include both axial heat conduction in the fluid phase and admits thermal gradient in the solids particles and finally a two dimensional single phase model. For each of these models a computer code was written and tested to evaluate the computing time of same data and analyze any other computational problems. The tests of thermal performance included particle size, porosity, particle material, flow rate, inlet temperature and heat losses form tank walls and extremities. Dynamics behaviour of the storage units due to transient variation in either flow rate or inlet temperature was also investigated. The results presented include temperature gradients, pressure drop and heat storage. The results ...

1991-07-01

480

Low temperature humidification dehumidification desalination process  

Energy Technology Data Exchange (ETDEWEB)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water temperature. Also, the water ...

2006-03-01

481

Low temperature humidification dehumidification desalination process  

International Nuclear Information System (INIS)

The humidification dehumidification desalination process is viewed as a promising technique for small capacity production plants. The process has several attractive features, which include operation at low temperature, ability to utilize sustainable energy sources, i.e. solar and geothermal, and requirements of low technology level. This paper evaluates the characteristics of the humidification dehumidification desalination process as a function of operating conditions. A small capacity experimental system is used to evaluate the process characteristics as a function of the flow rate of the water and air streams, the temperature of the water stream and the temperature of the cooling water stream. The experimental system includes a packed humidification column, a double pipe glass condenser, a constant temperature water circulation tank and a chiller for cooling water. The water production is found to depend strongly on the hot water temperature. Also, the water ...

2006-03-01

482

High Voltage Measurements on Nine PFNs for the LHC Injection Kicker Systems  

CERN Document Server

Each of the two LHC injection kicker magnet systems must produce a kick of 1.3 T.m with a flattop duration variable up to 7.86 microseconds, and rise and fall times of less than 900 ns and 3 microseconds, respectively. A kicker magnet system consists of four 5 Ohm transmission line magnets with matching terminating resistors, four 5 Ohm Pulse Forming Networks (PFN) and two Resonant Charging Power Supplies (RCPS). Nine PFNs, together with associated switch tanks, and dump switch terminating resistors have been built at TRIUMF and all have been tested at high voltage (54 kV) to ensure that the performance is within specification. This paper describes the HV measurements, compares these results with low voltage measurements and analyses the pulse performance of the PFNs. The measurements are compared with results from PSpice simulations and small discrepancies between the predictions and measurements are explained.

2005-01-01

483

Evaluation of specific consumption from the use of chicken oil biodiesel in one cylinder generator set; Avaliacao do consumo especifico a partir da utilizacao de biodiesel de oleo de frango em um grupo-gerador monocilindrico  

Energy Technology Data Exchange (ETDEWEB)

Biodiesel can be produced from numerous materials, including by-products of animal chain. In this scenario, the chicken's oil, that is located and an environment not explored for biodiesel production, can be a good alternative in South and Southeast Brazilian Region, where they are slaughtered around 9.100.000 chickens per day. In order to determine the specific consumption from a generator set with single cylinder 6.6 kW of power and generation capacity of 5 kW, using chicken oil biodiesel (B-100), were performed the bench test using a auxiliary tank, precision scale and an energy analyzer. Were conducted four treatments (25%, 50%, 75% and 100% of generating capacity). The worst SC was the engine at 25% of generation capacity (1.5 kW) and better with 75% of maximum load (3.75 kW) with a mean of 479.34 g kWh{sup -1}. By Turkey's test ant 5% probability there was a significant difference only for the first treatment. (author)

2010-07-01

484

Effect of natural rubber processing sludge on the degradation of crude oil hydrocarbons in soil  

Energy Technology Data Exchange (ETDEWEB)

Crude oil-polluted soil (five parts of weathered crude oil per 100 parts of soil; equivalent to 50,000 mg oil kg{sup -}1 soil) samples were slurried in deionised water (300% of the water retention capacity of the soil) and treated with various amounts of natural-rubber processing sludge (nitrogen content 62.15 mgkg{sup -1} and phosphorus contents 8.75 mgkg{sup -1}) in a well-stirred, continuously-aerated tank at 29{sup o}C. Changes in the total hydrocarbon content of the soil sample were determined, using a spectrophotometric technique, as a function of time. The extent of crude oil degradation was markedly higher (by up to 100%) in the sludge-treated soil than in the untreated soil sample. The efficiency of biodegradation of the crude oil hydrocarbons using the slurry-phase technique was compared with that of solid-phase technique. (author)

2002-03-01

485

Different purification methods and quality of sunflower biodiesel  

Energy Technology Data Exchange (ETDEWEB)

Biodiesel is derived from triacylglycerides and is produced primarily through transesterification, a chemical reaction of vegetable oils with alcohol, methanol or ethanol. The cost of raw material should be considered since 85 per cent of production cost is related to vegetable oil. The purpose of this study was to evaluate oil expression of sunflower seed. It also examined the sunflower crude oil as a raw material for biodiesel by transesterification in both laboratory and pilot scale studies. Three different biodiesel purification methods were examined. The best result for oil expelling (68.4 per cent) at the experimental stage was obtained for seeds with a moisture content of 6.9 per cent at 25 degrees C and at a screw speed of 114 rpm. For biodiesel production at the laboratory scale, the best result for oil expelling was 87.5 per cent. It was obtained with an ethanol:oil molar ratio of 4.7:1 and with a 4.42 per cent catalyst concentration related to the quantity of oil that had to ...

2010-07-01

486

Development of a 1200 KW/CYL low pressure dual fuel engine for LNG carriers  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design and feasibility tests of a 570 mm bore 4 stroke low pressure (L.P.) dual fuel engine rated at 20.9 bar BMEP meant for the propulsion of LNG carriers. The basic design features which are to be in accordance with classification societies safety rules are described: individual electro hydraulic valves located in the air manifold ducts, pilot injection, monitoring system etc. The engine capability to burn variable liquid/gas fuel proportions have been investigated with diesel oil and heavy fuel and possible running zones are defined. This ensures the possibility of the engine to cope with the different boil off gas quantity emanating from the ship`s tank during her loaded - and ballast - journeys. With the very lean setting of this engine, no adverse influence of the high ash lube-oil additives were found during the tests. Further tests are necessary to confirm that possible more significant fouling of the combustion chamber is still ...

1998-12-31

487

Continuous fermentative hydrogen production in different process conditions  

Energy Technology Data Exchange (ETDEWEB)

This paper reported on a study in which hydrogen was produced by fermentation of biomass. A continuous process using a non-sterile substrate with a readily available mixed microflora was used on heat treated digested sewage sludge from a wastewater treatment plant. Hydrogen was produced from waste sugar at a pH of 5.2 and a temperature of 37 degrees C. An experimental setup of three 5.5 L working volume continuously stirred tank reactors (CSTR) in different stirring speeds were constructed and operated at 7 different hydraulic retention times (HRTs) and different organic loading rates (OLR). Dissolved organic carbon was examined. The results showed that the stirring speed of 135 rpm had a beneficial effect on hydrogen fermentation. The best performance was obtained in 135 rpm and 8 h of HRT. The amount of gas varied with different OLRs, but could be stabilized on a high level. Methane was not detected when the HRT was less than 16 h. The study identified the ...

2010-07-01

488

Canadian upstream oil and gas industry fire and explosion incident analysis based on the investigative work of the IRP18 Committee working with the University of Calgary Department of Chemical and Petroleum Engineering. Revision 1  

Energy Technology Data Exchange (ETDEWEB)

This report presented an analysis of incidents gathered by the Canadian upstream oil and gas industry committee in relation to explosive atmospheres in wellbores, vessels, tanks, and piping systems. The aim of the report was to develop industry recommended practices for oil and gas industry fires and explosions. Two accident theory models were used to set out the relationships between hazards, defenses, and losses. Three levels of defenses were identified based on organizational, local workplace, and human factors. An organizational responsibility approach was used to examine the activities of key people with the system. Incidents were analyzed based on an expanded fire triangle used to identify fire and explosion hazards. The study showed that the ignition of hydrocarbons into the air was a factor in nearly 50 per cent of the incidents. A lack of understanding of liquid-hydrocarbon properties was demonstrated in incidents involving oxidized hydrocarbons. A lack of ...

2005-05-15

489

Behavior of inert gas contamination in high Ni alloy powder and consolidation powder material; Ko Ni gokin funmatsu funmatsu seikeitai ni okeru fukassei gas seibun no kyodo  

Energy Technology Data Exchange (ETDEWEB)

Inert gas contamination, structure and mechanical properties of consolidated high-Ni alloy powder material were studied to improve its characteristics. In experiment, the chemical composition and fraction of porosity in cross sections of Alloy 625 powder were examined which was produced by Ar gas atomization method impinging supplemental gas jet onto accumulated alloy powder in the bottom of a tank for rapid cooling. The structure and mechanical properties of the alloy rod were also examined which was produced by hot hydrostatic pressing or hot extrusion of the powder filled into a capsule. As a result, although Ar content included in the powder produced by Ar gas atomization method decreased with reduction in grain size, the fine powder less than 22{mu}m still included Ar of nearly 0.5mass-ppm. Obvious correlation was found between the fraction of porosity in powder cross sections and Ar in the powder. Although cavities were detected in the consolidated powder ...

1996-07-01

490

Anaerobic digestion of olive mill wastewaters  

Energy Technology Data Exchange (ETDEWEB)

Anaerobic treatment of olive oil mill wastewaters (COD up to 220 kg/cubic m) is feasible, and the most promising results were obtained on UASB reactors, both at laboratory and pilot scale (tank capacity 15 litres and 5 cubic m), fed on diluted waste (COD = 13-18 kg/cubic m). Volumetric loading rates ranging from 16-21.5 kg COD/cubic m/day and 70% removal efficiencies were obtained with these digesters. Start-up of UASB reactors fed on olive oil mill waste is a delicate step which still has to be fully controlled and optimized. The best results were obtained by starting with very diluted waste (COD = 5 kg/cubic m). Granulation of the sludge, as achieved in Dutch UASB digesters fed on sugar beet wastewaters, was not obtained, but, even so, the settleability of the sludge was very good. 22 references.

1984-01-01

491

An Experimental study on a Method of Computing Minimum flow rate  

International Nuclear Information System (INIS)

Many pump reliability problems in the Nuclear Power Plants (NPPs) are being attributed to the operation of the pump at flow rates well below its best efficiency point(BEP). Generally, the manufacturer and the user try to avert such problems by specifying a minimum flow, below which the pump should not be operated. Pump minimum flow usually involves two considerations. The first consideration is normally termed the 'thermal minimum flow', which is that flow required to prevent the fluid inside the pump from reaching saturation conditions. The other consideration is often referred to as 'mechanical minimum flow', which is that flow required to prevent mechanical damage. However, the criteria for specifying such a minimum flow are not clearly understood by all parties concerned. Also various factor and information for computing minimum flow are not easily available as considering for the pump manufacturer' proprietary. The objective of this study is to obtain experimental data for ...

2009-10-01

492

Advanced water purification facility; Kodo josui shori gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Accelerated oxidation treatment technology is introduced for use in the treatment of poor quality water by ozone injected from the bottom of a pressurized ozone contact tank. Under study as oxidation accelerating processes using ozone center about an ozone/hydrogen peroxide treatment, ozone/UV treatment, ozone/hydrogen peroxide/UV treatment, etc. As the result of testing, important respects in accelerated oxidation are learned, which are stated below. In the ozone-aided treatment, there are some substances, such as chromatic matters, that can be removed more rapidly when in direct contact with gaseous ozone. In this case, the concentration of remnant ozone poses an important problem. In relation to the amount of injected hydrogen peroxide, what is important is the ozone/hydrogen peroxide injection ratio relative to the substance that is to be removed. In the use of UV rays, since the decomposition rate of dissolved ozone is approximately ten times higher than that ...

1997-12-19

493

/sup 252/Cf-source-driven neutron noise analysis method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven neutron noise analysis method has been tested in a wide variety of experiments that have indicated the broad range of applicability of the method. The neutron multiplication factor k/sub eff/ has been satisfactorily detemined for a variety of materials including uranium metal, light water reactor fuel pins, fissile solutions, fuel plates in water, and interacting cylinders. For a uranyl nitrate solution tank which is typical of a fuel processing or reprocessing plant, the k/sub eff/ values were satisfactorily determined for values between 0.92 and 0.5 using a simple point kinetics interpretation of the experimental data. The short measurement times, in several cases as low as 1 min, have shown that the development of this method can lead to a practical subcriticality monitor for many in-plant applications. The further development of the method will require experiments oriented toward particular applications including dynamic ...

1985-01-01