WorldWideScience
2

A Laser-Pointer-Based Spectrometer for Endpoint Detection of EDTA Titrations  

Science.gov (United States)

A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations, however overall standard deviations depend on the skill of the student and their willingness to be careful and precise.

2004-12-01

3

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and ...

2005-10-23

4

Determination of radon and thoron permeability through some plastics by track technique  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

1986-01-01

5

Halon Flightline Extinguisher Evaluation: Data Supporting ...  

Science.gov (United States)

... Nacelle temperature was measured with a hand-held infrared thermometer for this series of evaluations instead of an installed thermocouple. 1 ...

2008-02-01

6

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

7

Radiation Isotope Identification Device (RIIDs) Field Test and Evaluation Campaign  

Energy Technology Data Exchange (ETDEWEB)

Handheld, backpack, and mobile sensors are elements of the Global Nuclear Detection System for the interdiction and control of illicit radiological and nuclear materials. They are used by the U.S. Department of Homeland Security (DHS) and other government agencies and organizations in various roles for border protection, law enforcement, and nonproliferation monitoring. In order to systematically document the operational performance of the common commercial off-the-shelf portable radiation detection systems, the DHS Domestic Nuclear Detection Office conducted a test and evaluation campaign conducted at the Nevada Test Site from January 18 to February 27, 2006. Named 'Anole', it was the first test of its kind in terms of technical design and test complexities. The Anole test results offer users information for selecting appropriate mission-specific portable radiation detection systems. The campaign also offered manufacturers the opportunity to ...

2007-08-01

8

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

9

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber ...

2007-08-21

10

Salt Lake City shows hot and cold spots - NASA ... - Science@NASA  

Science.gov (United States)

Jul 21, 1998 ... Additional roof surface temperatures were taken with a handheld "heat spy," an infrared thermometer to help calibrate the ATLAS thermal ...

11

An ecological analysis of knowing by wielding.  

UK PubMed Central (United Kingdom)

The ecological approach to perception, as developed by James Gibson, is described and applied to how one knows, by means of the haptic perceptual system, various properties of hand-held objects. Four...Full Text Available

1989-11-01

12

Air Shower Events of High-Energy Cosmic Rays Measured at Seoul, South Korea  

Science.gov (United States)

The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.

2011-09-01

13

Measurement of the oil consumption of compressors  

International Nuclear Information System (INIS)

This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).

14

A search for tachyons in cosmic ray showers  

International Nuclear Information System (INIS)

A search has been made of tachyons associated with cosmic ray showers of energies about 10"1"5 eV by searching for any precursor effects observed in plastic scintillator detectors. Detection thresholds well below most other similar experiments have been reached but no statistically significant effects have been found.

15

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

16

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

17

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light ...

1992-10-25

18

An Assessment of the Detection of Highly Enriched Uranium and its Use in an Improvised Nuclear Device using the Monte Carlo Computer Code MCNP-5  

Science.gov (United States)

In 2002 and again in 2003, an investigative journalist unit at ABC News transported a 6.8 kilogram metallic slug of depleted uranium (DU) via shipping container from Istanbul, Turkey to Brooklyn, NY and from Jakarta, Indonesia to Long Beach, CA. Targeted inspection of these shipping containers by Department of Homeland Security (DHS) personnel, included the use of gamma-ray imaging, portal monitors and hand-held radiation detectors, did not uncover the hidden DU. Monte Carlo analysis of the gamma-ray intensity and spectrum of a DU slug and one consisting of highly-enriched uranium (HEU) showed that DU was a proper surrogate for testing the ability of DHS to detect the illicit transport of HEU. Our analysis using MCNP-5 illustrated the ease of fully shielding an HEU sample to avoid detection. The assembly of an Improvised Nuclear Device (IND) -- a crude atomic bomb -- from sub-critical pieces of HEU metal was then examined via Monte Carlo ...

2007-04-01

19

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

20

Neutrino cross sections with the MINER?A Experiment  

British Library Electronic Table of Contents (United Kingdom)

MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...

2011-01-01

21

Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.

1990-01-01

22

Interactions of Jet Fuels with Nitrile O-Rings: Petroleum-Derived versus Synthetic Fuels  

Energy Technology Data Exchange (ETDEWEB)

A transition from petroleum~derived jet fuels to blends with Fischer-Tropsch (F~T) fuels, and ultimately fully synthetic hydro-isomerized F-T fuels has raised concern about the fate of plasticizers in nitrile-butadiene rubber a-rings that are contacted by the fuels as this transition occurs. The partitioning of plasticizers and fuel molecules between nitrile a-rings and petroleum-derived, synthetic, and additized-synthetic jet fuels has been measured. Thermal desorption of o-rings soaked in the various jet fuels followed by gas chromatographic analysis with a mass spectrometric detector showed many of the plasticizer and stabilizer compounds were removed from the o-rings regardless of the contact fuel. Fuel molecules were observed to migrate into the o-rings for the petroleum-derived fuel as did both the fuel and additive for a synthetic F-T jet fuel additized with benzyl alcohol, but less for the ...

2009-01-01

23

Large solid angle Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A conical Bragg-curve spectrometer (BCS) has been constructed. The outer case was a molded plastic cone. Printed circuit techniques were used to form an insert with inscribed equipotentials to approximate a 1/r/sup 2/ electric field shape. The charge and energy resolution were measured for elastically scattered beams of 206 MeV /sup 28/Si, 413 and 378 MeV /sup 56/Fe, and 670 MeV /sup 86/Kr ions. Performance of this detector, particularly its charge resolution, is discussed with respect to variation in solid angle.

1984-02-01

24

A large surface neutron and photon detector for civil security applications  

Energy Technology Data Exchange (ETDEWEB)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes ...

2010-05-21

25

A large surface neutron and photon detector for civil security applications  

International Nuclear Information System (INIS)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes ...

2010-05-11

26

Handbook of Soviet Reinforced Plastics,  

Science.gov (United States)

... Soviet standard or specification number for each reinforced plastic is included ... The tabular data contains general applications of reinforced plastics. ...

1973-03-31

27

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its ...

2005-01-01

28

Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia  

Energy Technology Data Exchange (ETDEWEB)

Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The ...

2006-07-01

29

Evaluation of surgical gamma probes for sentinel node localisation in cervical and vulvar cancer  

International Nuclear Information System (INIS)

Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and limitations should be considered in the appropriate selection of a device. (author)

30

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

31

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional ...

2010-09-07

32

Photon dosimetry using plastic scintillators in pulsed radiation fields  

Energy Technology Data Exchange (ETDEWEB)

Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an ...

2007-04-01

33

High resolution alpha-particle spectroscopy using CR-39 plastic track detector  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed for high resolution alpha particle spectroscopy from track length determination in CR-39 plastic. On individual tracks an energy resolution deltaE close to the range straggling limit is obtainable. For 6 MeV alpha-particle deltaE is proportional 35 keV on individual particles and for groups of particles deltaE proportional 20 keV can be achieved using certain data selection criteria. At 100 keV on individual particles deltaE is proportional 20 keV. The analysis requires 1) a knowledge of the track-etch rate (Vsub(T))-range relationship and 2) a theoretical understanding of alpha-particle track structure in CR-39 as a function of particle energy, dip angle and degree of etching. The structure of alpha-particle etched tracks in CR-39 is described and two methods of analysis discussed. Examples are given of the resolution attainable on tracks of alpha-particles as natural decay energy and from alpha-particles generated in laser driven ...

1984-06-15

34

Low-temperature oxidative degradation of PBX 9501 and its components determined via molecular weight analysis of the Poly[ester urethane] binder  

British Library Electronic Table of Contents (United Kingdom)

The results of following the oxidative degradation of a plastic-bonded explosive (PBX 9501) are reported. Into over 1100 sealed containers were placed samples of PBX 9501 and combinations of its components and aged at relatively low temperatures to induce oxidative degradation of the samples. One of the components of the explosive is a poly(ester urethane) polymer and the oxidative degradation of the samples were following by measuring the molecular weight change of the polymer by gel permeation chromatography (coupled with both differential refractive index and multiangle laser light scattering detectors). Multiple temperatures between 40 and 64 degreeC were used to accelerate the aging of the samples. Interesting induction period behavior, along with both molecular weight increasing (cro...

2009-01-01

35

ADS as Information Management Service in an M-Learning Environment  

CERN Document Server

Leveraging the potential power of even small handheld devices able to communicate wirelessly requires dedicated support. In particular, collaborative applications need sophisticated assistance in terms of querying and exchanging different kinds of data. Using a concrete example from the domain of mobile learning, the general need for information dissemination is motivated. Subsequently, and driven by infrastructural conditions, realization strategies of an appropriate middleware service are discussed.

2007-01-01

36

Design, construction and testing of a radon experimental chamber; Diseno, construccion y pruebas de una camara experimental de radon  

Energy Technology Data Exchange (ETDEWEB)

To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and proved a new automatic ...

1991-10-15

37

The JT-60U 2.45 MeV neutron time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. ...

1999-11-01

38

Pre-Flight Development of the PoGOLite Pathfinder  

International Nuclear Information System (INIS)

The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...

39

Waste recycling as evaluated from the viewpoint of energy environment, mainly about plastics; Haikibutsu recycle no energy kankyomen kara no hyoka. Plastic wo chushin to shite  

Energy Technology Data Exchange (ETDEWEB)

Some comments are given on the recycling of waste, mainly plastics, as evaluated from the viewpoint of energy environment. Discussed about the waste in general are the definition and classification, generation and resource recovery rates, current state of recycling, problems about recycling, related legislation, and current conditions overseas. Discussed about the treatment and recycling of plastics waste are the characters and use of plastic product, current state of waste plastics treatment, current state of waste plastics recycling (material recycling, thermal recycling), energy recovery by thermal recycling, quantity recyclable from waste plastics, energy consumption and cost for waste plastics recycling, effect and impact of increase in waste plastics in case material recycling is forwarded, and prospect of waste ...

1996-05-01

43

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. ...

1998-03-01

44

U.S. Government Capabilities to Support Analysis of Gamma Ray Data Submitted by Field Elements  

Energy Technology Data Exchange (ETDEWEB)

As radiation detection in the interest of national security becomes increasingly commonplace, inevitable questions arise concerning the interpretation of data from handheld radioisotope identifiers (RIIDs). Field elements typically require fast answers to provide an effective defense and to minimize the impact on legitimate movement of people and goods. To support this need, on-call experts at Sandia, Los Alamos, and Lawrence Livermore national laboratories cooperate in resolving radiation alarms rapidly and accurately. We present an overview, describe the work in progress to improve capabilities, and report on some of the lessons learned.

2005-07-07

45

Spectrochemical analysis using infrared multichannel detectors  

CERN Document Server

Spectrochemical analysis using infrared multichannel detectors

2007-01-01

46

CZT Detector and HXI Development at CASS/UCSD  

CERN Document Server

CZT Detector and HXI Development at CASS/UCSD

2006-01-01

47

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)  

CERN Document Server

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)

2011-01-01

48

Radon measurements in the Catalagzi Thermal Power Plant, Turkey  

Energy Technology Data Exchange (ETDEWEB)

The Catalagzi Thermal Power Plant (CTPP) is located at nearly 13 km North-east of Zonguldak city, which is located at the West Black Sea coast in Turkey. The middling products with high ash content of bituminous coals are used in this plant. Seasonal radon concentration measurements have been carried out by using CR-39 plastic track detectors in and around the CTPP. The annual average radon concentration has been found to vary from a minimum of 39.8 {+-} 28.9 Bq m{sup -3}) in the ash area to a maximum of about to 75.0 {+-} 15.7 Bq m{sup -3} in the service building of the power plant. The annual average radon concentration in the dwellings of the thermal power plant colony of the plant is 71.0 {+-} 33.4 Bq m{sup -3}. The effective dose has been found to vary from 0.38 to 0.71 mSv y{sup -1} with a mean value of 0.56 mSv y{sup -1}, which is lower than the effective dose values 3-10 mSv given as the range of action levels recommended by ...

2008-01-15

49

Development of production methods of volume source by the resinous solution which has hardening  

CERN Document Server

Volume sources is used for standard sources by radioactive measurement using Ge semiconductor detector of environmental sample, e.g. water, soil and etc. that require large volume. The commercial volume source used in measurement of the water sample is made of agar-agar, and that used in measurement of the soil sample is made of alumina powder. When the plastic receptacles of this two kinds of volume sources were damaged, the leakage contents cause contamination. Moreover, if hermetically sealing performance of volume source made of agar-agar fell, volume decrease due to an evaporation off moisture gives an error to radioactive measurement. Therefore, we developed the two type methods using unsaturated polyester resin, vinilester resin, their hardening agent and acrylicresin. The first type is due to dispersing the hydrochloric acid solution included the radioisotopes uniformly in each resin and hardening the resin. The second is due to ...

2002-01-01

50

Alpha-particle autoradiography in Cr-39. The determination of the microdistribution of activity and trace element analysis  

Energy Technology Data Exchange (ETDEWEB)

New and elaborate techniques for alpha-particle autoradiography of thick specimens based on the plastic nuclear track detector CR-39 have been developed. These permit a full analysis of both trace element and microdistribution of alpha-active nuclides present. The important features of the techniques are: 1) reliable low level configuration down to 10/sup -15/ Ci g/sup -1/, 2) high resolution alpha-particle spectroscopy in CR-39, 3) determination of the absolute abundance of alpha active nuclides present in the specimen, 4) determination of the distribution of emission with height up to 30 microns above the surface of the autoradiograph, 5) the local determination of the radon diffusion coefficient in the specimen which is needed to calculate the activity levels of /sup 222/Rn and daughter nuclei, 6) the analysis of small and large clusters of alpha-particle activity recorded on the autoradiograph. These techniques are briefly discussed.

1984-06-15

51

NAME=\\  

Wastenet

... Biodegradable plastics have the potential to be used in various flushable sanitary product applications such as sanitary towels, colostomy bags and other absorbent products. In addition, effluent from recycling activities must be treated in wastewater treatment plants and may contain biodegradable plastics. Flushable biodegradable plastics can have an adverse impact on wastewater treatment plants due to the very fast throughputs, typically 4 to 8 hours, from the drain to the plant. This length of time is insufficient for many biodegradable plastics to lose their structure. Such plastics can ...

52

Imaging of coronary artery stents using multislice computed tomography: in vitro evaluation  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate imaging features of different coronary artery stents during multislice CT Angiography (MSCTA). Nineteen stents made of varying material (steel, nitinol, tantalum) and of varying stent design were implanted in plastic tubes with an inner diameter of 3 mm to simulate a coronary artery. The tubes were filled with iodinated contrast material diluted to 200 Hounsfield units (HU), closed at both ends and positioned in a plastic container filled with oil (-70 HU). The MSCT scans were obtained perpendicular to the stent axes (detector collimation 4 x 1 mm, table feed 2 mm/rotation, 300 mAs, 120 kV). Axial images and multiplanar reformations were evaluated regarding artifact size, lumen visibility, and intraluminal attenuation values. Artifacts characterized by artifactual thickening of the stent struts leading to apparent reduction in the lumen diameter and increased intraluminal attenuation ...

2003-04-01

53

Transport and release of chemicals from plastics to the environment and to wildlife  

UK PubMed Central (United Kingdom)

Plastics debris in the marine environment, including resin pellets, fragments and microscopic plastic fragments, contain organic contaminants, including polychlorinated biphenyls (PCBs), polycyclic...Full Text Available

2009-07-27

54

Recycling of postconsumer plastic waste via new solid-state shear extrusion pulverization process  

Energy Technology Data Exchange (ETDEWEB)

We have demonstrated that the SSSE pulverization process can convert multicomponent plastic waste into a powder with very promising properties. A variety of mixed color plastic chips have been pulverized.

1996-12-31

55

Recycling of plastic waste in blast furnace; Koro ni okeru hai plastic riyo gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Features particular to the technology of using a blast furnace for the recycling of plastic waste are reported, and the behavior of plastic waste injected into a blast furnace is described. The plastic waste is injected into the furnace borne on a 1200degC hot blast through the tuyere. The plastic is converted into a reducing gas in the furnace, and the gas on its way up in the furnace is utilized as a reducing agent in the iron ore reducing reaction. The process is described below. All kinds of plastic waste may be utilized in this fashion, with the exception of polyvinyl chloride. As for polyvinyl chloride, efforts are under way to develop a technology to recycle this plastic. The method using the blast furnace tolerates a wide range of impurities, and the plastic waste is only to be crushed and granulated before use in the furnace. ...

1998-05-20

56

Waste plastic treatment equipment; Hai plastic shori sochi  

Energy Technology Data Exchange (ETDEWEB)

In recent years, there has been increasing demand for resource-recycling of waste plastic, especially due to the introduction of legislation on recycling of materials used for packages of household goods. Methods of recycling waste plastic from household goods are currently still under development, and appropriate techniques to deal with such waste are required. Toshiba has developed a technique to dehydrochlorinate plastic containing polyvinyl chloride (PVC). This paper introduces our petrolization and dehydrochlorination system for waste plastic containing PVC. (author)

1999-04-01

57

Unraveling mechanisms of homeostatic synaptic plasticity  

UK PubMed Central (United Kingdom)

SUMMARYHomeostatic synaptic plasticity is a negative feedback mechanism neurons use to offset excessive excitation or inhibition by adjusting their synaptic strengths. Recent...Full Text Available

2010-05-13

58

Management of Contaminated Autologous Grafts in Plastic Surgery  

UK PubMed Central (United Kingdom)

Background: Contamination of autologous grafts unfortunately occurs in plastic surgery, but the literature provides no guidance for management of such incidents. Methods: American...Full Text Available

59

Adhesive 'PED-B' for Cementing Plastics of Formula 57-40 to ...  

Science.gov (United States)

... Title : Adhesive 'PED-B' for Cementing Plastics of Formula 57-40 to the Surfaces of Contruction Units,. ... Glue PED-B is not explosive. ...

1964-08-20

60

A Research Needs Assessment for waste plastics recycling: Volume 2, Project report. Final report  

Energy Technology Data Exchange (ETDEWEB)

This second volume contains detailed information on a number of specific topics relevant to the recovery/recycling of plastics.

1994-12-01

61

Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS  

Energy Technology Data Exchange (ETDEWEB)

To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from ...

2006-07-01

62

Plastic wastes as support fuel. Jaetemuovin kaeyttoe tukipolttoaineena  

Energy Technology Data Exchange (ETDEWEB)

The association of Finnish Plastics Industry examined the possibilities to utilize energy content of plastic wastes in spring 1990. A bark fuelled boiler plant of forest industry was used as test power plant. The power of the plant was 60 Mw. This report discusses shortly the theory of combustion of plastics. About 130 000-15 000 tons of plastic waste, corresponding to 7 % of the solid municipal waste, is dumped annually in Finland. Utilization of the plastic waste recovered from municipal wastes for energy production is technically viable in present power plants among present energy production. The chipping and mixing of the plastic in the other fuel are the only pretreatment required for the plastic waste. In Finland there are several power plants using suitable fuels for plastic mixture combustion. The portion of the ...

1991-01-01

64

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

70

Calculation of ventilation requirements in the case of intermittent pollution: application to enclosed parking garages  

Energy Technology Data Exchange (ETDEWEB)

The ventilation requirements for decontamination are normally determined with a static calculation method. In some cases, the pollutant emission is intermittent, for example in the car park of an office building, where all the cars enter and leave the place nearly at the same time. Generally, in such a case, the volume of the garage is large, consequently the time constant of the system has a high value. So a static approach would no longer stay accurate and a dynamic evaluation is needed. With the help of some assumptions, calculations remain rather simple and results can be plotted on nomographs or computed on a programmable handheld calculator. The amount of energy saved may appear very large in some cases. A sizing optimization will be required but also remains easy to compute. The paper presents the method of calculation for a single ventilation level and the optimization of a two-level ventilation.

1982-01-01

71

Utilization of plastic wastes in a blast furnace - a contribution to ecological and economical recycling of plastic wastes; Kunststoffverwertung im Hochofen - ein Beitrag zum oekologischen und oekonomischen Recycling von Altkunststoffen  

Energy Technology Data Exchange (ETDEWEB)

This article describes the utilization of plastic wastes in a blast furnace. The plastic waste is a substitution for petroleum and coal as a raw material for synthesis gas production. The synthesis gas is the reducing agent in the blast furnace for the reduction of iron ores. You can find here an ecological and economical analysis of this process in comparison to the utilization of petroleum and coal. (SR)

1996-12-31

72

Plastic film recycling: A new beginning  

Energy Technology Data Exchange (ETDEWEB)

Only two years ago, plastic film recycling was considered an onerous task. Different resins had to be identified, colors had to be separated, and minute contaminants had to be weeded out almost by hand to produce a quality material. But the tide of plastic film recycling is changing now that new technologies have emerged and more organized collection infrastructure have been developed. Today, plastic film recycling maintains a lucrative market for those with the right combination of equipment and know-how.

1995-02-01

73

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

74

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

75

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

76

Biology of lichen communities in Antarctica.  

Science.gov (United States)

-Ecophysiological and floristic study of the lichen communities in .... Plasticity of the Lichen Catillaria corymbosa in Different Microhabitats of the ...

77

Small world when building a particle detector prototype, the devil is in the tiny details  

CERN Multimedia

Small world when building a particle detector prototype, the devil is in the tiny details

2004-01-01

78

Photodiode Scintillation Detector for Anti-Coincidence Shielding  

Science.gov (United States)

Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...

79

Recycling plastic scrap: injection molding. January 1973-August 1988 (Citations from the Rubber and Plastics Research Association data base). Report for January 1973-August 1988  

Energy Technology Data Exchange (ETDEWEB)

This bibliography contains citations concerning the recycling of scrap plastic produced in the injection-molding process. Plastic pellets made from scrap that are used in the injection-molding process are also discussed. Recycling equipment and automated recycling systems are described. Ways to utilize plastic scrap from used cars, packaging materials, and waste from polyurethane production are presented. (This updated bibliography contains 102 citations, 13 of which are new entries to the previous edition.)

1988-08-01

80

Recycling plastic scrap: Injection molding. January 1973-August 1989 (Citations from the Rubber and Plastics Research Association data base). Report for January 1973-August 1989  

Energy Technology Data Exchange (ETDEWEB)

This bibliography contains citations concerning the recycling of scrap plastic produced in the injection-molding process. Plastic pellets made from scrap that are used in the injection-molding process are also discussed. Recycling equipment and automated recycling systems are described. Ways to utilize plastic scrap from used cars, packaging materials, and waste from polyurethane production are presented. (This updated bibliography contains 116 citations, 14 of which are new entries to the previous edition.)

1989-09-01

81

Recycling plastic scrap: Injection molding. (Latest citations from the Rubber and Plastics Research Association database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the recycling of scrap plastic produced in the injection molding process. Plastic pellets made from scrap, that are used in the injection molding process, are also discussed. Recycling equipment and automated recycling systems are described. The reuse of plastic scrap culled from junk automobiles and packaging materials is discussed, and waste byproducts from polyurethane production are described. (Contains a minimum of 80 citations and includes a subject term index and title list.)

1994-05-01

82

Recycling plastic scrap: Injection molding. (Latest citations from the Rubber and Plastics Research Association database). Published Search  

Energy Technology Data Exchange (ETDEWEB)

The bibliography contains citations concerning the recycling of scrap plastic produced in the injection molding process. Plastic pellets made from scrap, that are used in the injection molding process, are also discussed. Recycling equipment and automated recycling systems are described. The reuse of plastic scrap culled from junk automobiles and packaging materials is discussed, and waste byproducts from polyurethane production are described. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

1997-02-01

83

Measurement of. beta. decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 less than or equal toA less than or equal to106 and A=109. Messung von Beta-Zellverfallsenergien kurzlebiger, neutronenreicher Atomkerne im Massenbereich 101 less than or equal toA less than or equal to106 und A=109  

Energy Technology Data Exchange (ETDEWEB)

Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values in keV). For the measurement of beta-gamma ...

1986-10-31

84

Measurement of #beta# decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 #<=# A #<=# 106 and A=109  

International Nuclear Information System (INIS)

Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma coincidences a #DELTA#E/E-plastic ...

85

Application of passive type radon detectors to find fissures in banks caused by the southern Hyogo prefectural earthquake in Japan  

International Nuclear Information System (INIS)

Innumerable fissures were formed widely in Hanshin area in Japan by the former southern Hyogo prefectural earthquake occurred on Jan.17, 1995. In this study, as a preliminary investigation, we applied passive type radon detector Pico-Rad (U.S. Packard Instrument Co. Ltd.) with hemispheric plastic cover over them around the fissure along on the bank of two reservoirs to examine whether there is possibility to find fissures using the characteristics of "2"2"2Rn migration. One of the reservoir, Taniyamakami-ike, is located at the north of the Awaji-shima island at a distance of about 4 km from the seismic center of this earthquake. On the whole, "2"2"2Rn exhalation rates were high on a line of 2 m below the edge of the bank and got lower in proportion to the distance from this line. Those top of the bank had middle values among the lines. The mean "2"2"2Rn exhalation rate was 4.7 mBq m"-"2 s"-"1, and in these data we found some singularly high ...

86

Use of post-consumer waste plastics in cement-based composites  

Energy Technology Data Exchange (ETDEWEB)

This paper describes an innovative use of post-consumer waste HDPE plastic in concrete as a soft filler. A reference concrete was proportioned to have the 28-day compressive strength of 5000 psi (35 MPa). A high-density plastic was shredded into small particles for use in the concrete. These particles were subjected to three chemical treatments (water, bleach, bleach + NaOH) to improve their bonding with the cementitious matrix. The plastic particles were added to the concrete in the range of 0--5% of total mixture by weight. Compressive strengths were measured for each test mixture. The results showed that chemical treatment has a significant effect on performance of the plastic filler in concrete. Of the three treatments used on the plastic, the best performance was observed with the alkaline bleach treatment (bleach + NaOH) with respect to compressive strength of concrete.

1996-10-01

87

Oil-filled electric cable with alternate layers of plastic and paper tape  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an oil-filled electric cable and a manufacturing method for said cable, in which the solid insulation is formed, at least in part, by separately applied, alternate layers of cellulose paper tape and of film tapes made of plastic. Prior to application of the tapes around the cable conductor, the moisture content of the paper tape is selected and the swelling of the plastic tape by the oil after application is adjusted, if necessary, such as by immersing the plastic tape in the oil prior to application, so that the swelling of the plastic tape by the oil in the formed cable is offset by the shrinkage of the paper tape during drying of the cable. Also, an apparatus for pre-swelling the plastic tape is described. 4 figs.

1988-01-12

88

U. S. Navy shipboard-generated plastic-waste pilot-recycling program. Research and development report, Apr 90-Jan 91  

Energy Technology Data Exchange (ETDEWEB)

From April 1990 through January 1991, the feasibility of recycling Navy shipboard-generated plastic wastes was explored. Normally, plastic wastes are source separated aboard Navy ships and retained for shoreside disposal in accordance with new fleet requirements implementing MARPOL Annex V that prohibits the discharge of plastics at sea. Over 23,000 pounds of shipboard plastic wastes from USS Lexington (AVT 16) and ships from the Norfolk Naval Base were recycled into park benches, picnic tables and carstops that have been distributed back to the Navy bases for use. Navy shipboard plastics must undergo sorting prior to recycling because Navy plastic waste contains large quantities of composite plastic items (e.g., plastic/paper) that are not easily recyclable. Recycling food-contaminated plastics is ...

1991-03-01

89

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

90

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

91

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

92

p-Nonyl-phenol: an estrogenic xenobiotic released from "modified" polystyrene.  

UK PubMed Central (United Kingdom)

Alkylphenols are widely used as plastic additives and surfactants. We report the identification of an alkylphenol, nonylphenol, as an estrogenic substance released from plastic centrifuge tubes. This...Full Text Available

1991-05-01

93

Tone-Specific and Nonspecific Plasticity of the Auditory Cortex Elicited by Pseudoconditioning: Role of Acetylcholine Receptors and the Somatosensory Cortex  

UK PubMed Central (United Kingdom)

Experience-dependent plastic changes in the central sensory systems are due to activation of both the sensory and neuromodulatory systems. Nonspecific changes of cortical auditory neurons elicited by...Full Text Available

2008-09-01

94

Study of wood plastic composite in the presence of nitrogen containing additives  

Energy Technology Data Exchange (ETDEWEB)

Effect of nitrogen-containing additives in the study of wood plastic composites of MMA with simul and mango wood of Bangladesh has been investigated. Nine different additives were used and the additives containing carboamide group induce the highest tensile strength to the composite. (author).

1994-10-01

95

Study of wood plastic composite in the presence of nitrogen containing additives  

International Nuclear Information System (INIS)

Effect of nitrogen-containing additives in the study of wood plastic composites of MMA with simul and mango wood of Bangladesh has been investigated. Nine different additives were used and the additives containing carboamide group induce the highest tensile strength to the composite. (author).

1994-01-01

96

Study of wood plastic composite in the presence of nitrogen containing additives  

Science.gov (United States)

Effect of nitrogen-containing additives in the study of wood plastic composites of MMA with simul and mango wood of Bangladesh has been investigated. Nine different additives were used and the additives containing carboamide group induce the highest tensile strength to the composite.

1994-10-01

97

Metabolic Engineering of Poly(3-Hydroxyalkanoates): From DNA to Plastic  

UK PubMed Central (United Kingdom)

Poly(3-hydroxyalkanoates) (PHAs) are a class of microbially produced polyesters that have potential applications as conventional plastics, specifically thermoplastic elastomers. A wealth of biological...Full Text Available

1999-03-01

98

Maturation of GABAergic Inhibition Promotes Strengthening of Temporally Coherent Inputs among Convergent Pathways  

UK PubMed Central (United Kingdom)

Spike-timing-dependent plasticity (STDP), a form of Hebbian plasticity, is inherently stabilizing. Whether and how GABAergic inhibition influences STDP is not well understood. Using a model neuron driven...Full Text Available

2010-06-01

99

Late onset muscle plasticity in the whisker pad of enucleated rats  

UK PubMed Central (United Kingdom)

Blindness leads to a major reorganization of neural pathways associated with touch. Because incoming somatosensory information influences motor output, it is plausible that motor plasticity occurs in...Full Text Available

2008-10-14

100

Glutamate Receptor-Mediated Restoration of Experience-Dependent Place Field Expansion Plasticity in Aged Rats  

UK PubMed Central (United Kingdom)

Place fields of hippocampal pyramidal cells expand asymmetrically when adult rats repeatedly follow the same route. This behaviorally-induced expression of neuronal plasticity utilizes an NMDAR-dependent,...Full Text Available

2008-06-01

101

Conditioning of plastic wastes for thermal utilization; Aufbereitung von Kunststoffabfaellen zur thermischen Verwertung  

Energy Technology Data Exchange (ETDEWEB)

This article describes the processes for the treatment of plastic waste: sampling, sorting, comminution. The requirements for the different processes for waste treatment (as recycling, utilization as raw material, energy recovery, combustion) are listed. (SR)

1996-12-31

102

A Kinetic Model of Dopamine- and Calcium-Dependent Striatal Synaptic Plasticity  

UK PubMed Central (United Kingdom)

Corticostriatal synapse plasticity of medium spiny neurons is regulated by glutamate input from the cortex and dopamine input from the substantia nigra. While cortical stimulation alone results in long-term...Full Text Available

2010-02-01

103

A History of Spike-Timing-Dependent Plasticity  

UK PubMed Central (United Kingdom)

How learning and memory is achieved in the brain is a central question in neuroscience. Key to today’s research into information storage in the brain is the concept of synaptic plasticity, a...Full Text Available

105

Wood-plastic composites with high toughness and dimensional stability  

International Nuclear Information System (INIS)

Using acrylic-group containing isocyanates together with methyl methacrylate as impregnating mixture and gamma rays for curing wood-plastic composites have been produced, which show high-dimensional stability and toughness (low brittleness) compared to commonly used wood-plastics. The syntheses of proper acrylic-group containing isocyanates are as well described as the properties of the produced composites, made from maple wood. Also the direct use of the initial compounds, necessary for the syntheses, resulted in products of similar properties. These wood-plastic composites are to be suggested for the production of high-class products, e.g. wood-wind instruments. (author).

1982-10-01

106

The influence of plastic materials on the formation of tars in the gasification of urban waste wood  

Energy Technology Data Exchange (ETDEWEB)

Gasification experiments were performed using urban waste wood (Altholz) with additions of polymers typical for separately collected waste plastics. The resulting tar product distributions are discussed in this paper. The amount of tars is shown to be a function of operation parameters of the gasifier as well as the fuel. Plastics admixture yields higher concentrations of aromatic tar compounds in the gases, even if the plastic used is not aromatic in its structure. Such mixtures can be gasified for the production of synthesis gas, but clearly a larger effort will be required in cleaning the gases. (author)

2001-03-01

108

Plastics with a bright future; Kunststoffe mit leuchtender Zukunft  

Energy Technology Data Exchange (ETDEWEB)

Flexible solar cells or luminous foils have become reality with organic electronic systems.

2010-07-01

109

Multiscale Mechanical Characterization of Biomimetic Gels for ...  

Science.gov (United States)

... MECHANICAL PROPERTIES, *COPOLYMERS, *SOFT TISSUES, *GELS, *BIOMIMETICS, ISOPRENE, WOUND BALLISTICS, STYRENE PLASTICS ...

2006-11-01

110

Long-term hygrothermal effects on damage tolerance of hybrid composite sandwich panels  

Science.gov (United States)

A sandwich construction, composed of hybrid carbon-glass fiber-reinforced plastic skins and a

1995-01-01

111

It is petrochemical of the waste plastic; Hai purasutikku no yuka  

Energy Technology Data Exchange (ETDEWEB)

It becomes a cause of the air pollution by the generation of hydrogen chloride, when it is incinerated, when it decays, even if the plastic which becomes spent is buried. Every year, it is abundantly discharged and accumulates. Countries and enterprises, etc. carry out the examination for non-polluting processing and resource recycling of the waste plastic for material recycling and development by methods such as thermal recycling, practical application. In this paper, the following are examined: Plastic output and transition of the situation of the disposal quantity, resource recycling and problem. It wants to explain the challenge of more and more efficient resource recycling. (NEDO)

1999-11-01

112

Hollow Glass Filament Reinforced Plastics for Deep ...  

Science.gov (United States)

... Problems investigated in various basic hollowness ratios include ultimate compressive strength, fatigue properties, buckling characteristics, and ...

1966-02-08

113

Explosive Performance Modification by Cosolidification of ...  

Science.gov (United States)

... A booster pellet, normally Comp B, was placed in the tube and an exploding bridgewire (EBW) detonator in a plastic holder was glued in with a ...

1976-10-01

115

Development of waste plastics utilization system in rotary lime-kiln; Sekkaishoseiro ni okeru purasuchikku nenryoka gijutsu  

Energy Technology Data Exchange (ETDEWEB)

We developed the technology of using a waste plastic as fuel in the rotary kiln from reducing the fuel cost and recycling resource point of view. It has established based upon the research of a primary combustion characteristics on waste plastics, the research of the combustion mode of the fuel in the rotary kiln by simulation and the actual examination of kiln. The first rotary kiln equipped with the waste plastic injection system has been operating since 1994, and has achieved a good operating result. (author)

1999-03-01

118

Advances and challenges of wood polymer composites  

Science.gov (United States)

... polypropylene, polylactic acid and polyvinyl chloride to form wood plastic composites (WPC). WPCs have seen a large growth in ... ...

119

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

120

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.

2008-10-01

121

Waste management and degradability  

Energy Technology Data Exchange (ETDEWEB)

Landscape visive pollution due to photo-biodegradable plastic bags is assessed in an ideal case, the most favorable to their use. The result is that mean permanent visive pollution is 100 times higher than established norms. Both photo and biodegradability of plastic bags in the real world are discussed. The conclusion is that photo-biodegradability does not solve the problem of landscape visive pollution due to plastic bags.

1987-01-01

122

Laser cutting plastic materials  

Energy Technology Data Exchange (ETDEWEB)

A 1000-watt CO/sub 2/ laser has been demonstrated as a reliable production machine tool for cutting of plastics, high strength reinforced composites, and other nonmetals. More than 40 different plastics have been laser cut, and the results are tabulated. Applications for laser cutting described include fiberglass-reinforced laminates, Kevlar/epoxy composites, fiberglass-reinforced phenolics, nylon/epoxy laminates, ceramics, and disposable tooling made from acrylic.

1980-08-01

123

Investigation into superplasticity of Be alloys  

International Nuclear Information System (INIS)

Investigated are the characteristics of high-temperature plastic deformation the velocity sensitivity of flow stresses, deformation curves, flow stresses, deformation before rupture - as well as the structure of beryllium alloys containing nickel (0.5-4 %), yttrium (0.5-2 %) and aluminium (38 %). The alloys containing nickel (2%) and yttrium (0.5 %) are superplastic, however, deformation before fracture of the alloys is lower than that of the unalloyed beryllium. The singularities of high-temperature plastic flow of the alloys and the causes of deterioration of their plasticity are determined.

124

Active recycling of plastics  

Energy Technology Data Exchange (ETDEWEB)

The numerous types of plastic materials and their varying structures of use call for different recycling techniques. This situation is illustrated by the survey of the most important recycling methods. Depending on origin and type of plastic waste, not only different recycling methods have to be adopted, but the resulting recycling materials are also used for different purposes. Disintegration of thermoplastic particles and waste into granular matter and grains which can be directly reused is particularly important.

1987-01-01

125

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

126

First results from the Lund NMP particle detector system  

International Nuclear Information System (INIS)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-06-15

127

First results from the Lund NMP particle detector system  

British Library Electronic Table of Contents (United Kingdom)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-01-01

128

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

129

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector  

CERN Document Server

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector

1993-01-01

130

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

131

Optimization of mechanical properties of recycled plastic products via optimal processing parameters using the Taguchi method  

British Library Electronic Table of Contents (United Kingdom)

The large amount of plastic products presently produced necessitates recycling and reuse of these non-biodegradable materials. However, the degradation in the mechanical properties of products made from recycled plastic is a major drawback that limits their use. This study aims to improve the mechanical properties of products made from recycled plastic by utilizing the Taguchi optimization method, instead of coupling the products with additives. By adopting L9 Taguchi OA, products made from various compositions of virgin and recycled plastic are produced by injection moulding. Four controllable factors (i.e., melt temperature, packing pressure, injection time, and packing time), each at three levels, are tested to determine the optimal combination of factors and levels in the manufacturing...

2011-01-01

132

Prediction of the intramuscular fat content in loin muscle of pig carcasses by quantitative time-resolved ultrasound  

British Library Electronic Table of Contents (United Kingdom)

A novel method for non-destructive intramuscular fat (IMF) estimation via spectral ultrasound backscatter analysis of signals obtained from pig carcasses early post mortem is described. A commercial hand-held ultrasound device (center frequency: 2.7MHz) was modified to focus the sound beam to the longissimus muscle at the 2nd/3rd last rib. Time-resolved ultrasound backscatter signals of loin muscle were recorded 45minp.m. on 82 pig carcass sides. Backfat width (d"B"F=18.9+/-3.8mm) and muscle attenuation (@a"m"u"s"c"l"e=.77+/-.15dBMHz^-^1cm^-^1) were assessed from the measured pulse echo data. Other propagation properties of skin, backfat and muscle tissue obtained in a previous investigation were incorporated into the signal pre-processing to minimize parameter estimation artifacts. Spectr...

2012-01-01

133

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The ...

2003-03-04

134

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

135

Use of signal delay of one of detectors in two-channel radiometric flaw detector  

International Nuclear Information System (INIS)

A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.

136

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

141

Developments and tests of double-sided silicon strip detectors and read-out electronics for the Internal Tracking System of ALICE at LHC  

CERN Document Server

The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.

1999-01-01

142

Application of Pd silicide in the process of silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.

1990-04-01

143

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

144

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

145

Influence of Dopants on Characteristics of X-Ray Detectors Fabricated from Indium-, Gallium-, and Chlorine-Doped Cadmium Telluride Single Crystals  

Science.gov (United States)

Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.

1995-08-01

146

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this ...

2011-02-01

147

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

148

Recycling of plastic packaging in Fredrikstad municipality. Climate accounts and other environmental factors; Kildesortering av plastemballasje i Fredrikstad kommune. Klimaregnskap og andre miljoefaktorer  

Energy Technology Data Exchange (ETDEWEB)

Oestfold Research has trough the project 'Climate accounts for disposal' for Waste Norway developed a model for calculation of net greenhouse gas emissions at the disposal of various waste types. The model is based on life cycle methodology according to the standard IS014044. This model has been used for plastic packaging in the project by adapting the basic values of specific conditions in the municipality of Fredrikstad. Oestfold Research has made an assessment of greenhouse gas emissions for the recycling and material recovery of plastic packaging from households in the district on assignment from Fredrikstad municipality and compared with the current solution where plastic packaging together with residual waste is used for energy utilisation. Based on the population in Fredrikstad and estimated amount of plastic packaging waste arising per household per year the difference in ...

2009-11-15

149

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

150

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

151

Core simulations using actual detector readings for a Canada deuterium uranium reactor  

Science.gov (United States)

This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.

1991-02-01

152

Technological physics and special materials: wood-plastic composites obtained by radiation polymerization  

International Nuclear Information System (INIS)

General estimates and references are made in connection with the role of technological physics in obtaining materials with specific features. The first part of the paper presents the modification of weak wood essences as well as technological processes at bench-scale and semi industrial scale of wood-plastic composites, under various irradiation conditions. Two technological installations for the fabrication of wood-plastic composites on both scales with technical and practical specifications of their performances are presented. Experimental data for different wood-plastic composite systems using some local wood essences in combination with several polymer and copolymer systems are given. Impregnation and polymerization levels are mentioned for every specific system. The radiation dose rate and integrated dose are given for every experimental polymerization system. The features of the wood-plastic ...

1995-12-02

153

Grafting of wood pulp with thermoplastic sidechains to make wood/plastic composites  

Energy Technology Data Exchange (ETDEWEB)

A method of grafting lignin-containing materials is now known which allows 1-phenylethylene or 4-methyl-2-oxy-3-oxopent-4-ene graft copolymers of wood to be quantitatively made. Graft copolymer is formed by conducting a free-radical polymerization with 1-phenylethene in nitrogen-saturated, organic or aqueous/organic solvent containing a lignin source, calcium chloride, and a hydroperoxide. Grafting changes solubility and surface properties of the wood. The lignin-containing materials grafted are unbleached wood pulps produced by chemical, thermal, and mechanical pulping. Grafting wood pulp produces a wood-reinforced, thermoplastic composite. When a particular plastic is to be blended with wood, we react the wood with the monomer used to make that plastic. This creates a hydrophobic surface of the plastic on the wood. This plastic coating can readily bond to the continuous plastic ...

1995-12-01

154

Quality Concepts for the Improved Use of Recycled Polymeric Materials: A Review  

British Library Electronic Table of Contents (United Kingdom)

Polymeric waste materials should be considered resources for the manufacture of new products through recycling processes, with a similar status to virgin fossil-based plastics and biopolymers from renewable resources. Several efforts can be made to achieve this qualitative quantum leap in plastics recycling, and consequently introduce recycled products, with competitive performance, to the market. Scientific knowledge about the degradation processes during the life cycle and the development of fast and reliable analytical methods for the quality assessment of recycled plastics are fundamental to guarantee their performance in new applications. Different strategies-restabilisation, rebuilding, compatibilisation, and addition of elastomers and fillers-can be used to upgrade the structure and...

2008-01-01

155

Magnetic Properties of a Material Used to Estimate Elastic and Plastic Strains of Ferrite?Pearlite Steels  

British Library Electronic Table of Contents (United Kingdom)

The effect of elastic and plastic strains on the magnetic properties of ferrite-pearlite steels has been studied. It has been shown that the sensitivity to elastic-tensile and bending strains is four to five times greater for remnant magnetization than for coercive force. In order to determine the degree of cold plastic deformation of high-carbon steels, a two-parametric testing technique based on the use of remnant magnetization and coercive force was suggested. An MMT-2 device was recommended for measurement of the required parameters.

2005-01-01

156

Quantum entanglement, recoherence and information flow in an accelerated detector - quantum field system: Implications for black hole information issue  

CERN Document Server

We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the detector never ...

2007-01-01

157

X-ray Microdiffraction and Strain Gradient Crystal Plasticity Studies of Geometrically Necessary Dislocations Near a Ni Bicrystal Grain Boundary  

Energy Technology Data Exchange (ETDEWEB)

We compare experimental measurements of inhomogeneous plastic deformation in a Ni bicrystal with crystal-plasticity simulations. Polychromatic X-ray microdiffraction, orientation imaging microscopy and scanning electron microscopy, were used to characterize the geometrically necessary dislocation distribution of the bicrystal after uniaxial tensile deformation. Changes in the local crystallographic orientations within the sample reflect its plastic response during the tensile test. Elastic strain in both grains increases near the grain boundary. Finite element simulations were used to understand the influence of initial grain orientation and structural inhomogeneities on the geometrically-necessary dislocations arrangement and distribution and to understand the underlying materials physics.

2009-01-01

158

The Arc of synaptic memory  

UK PubMed Central (United Kingdom)

The immediate early gene Arc is emerging as a versatile, finely tuned system capable of coupling changes in neuronal activity patterns to synaptic plasticity, thereby optimizing information...Full Text Available

2010-01-01

159

Structure and properties of a metastable #beta#-alloy aged after plastic deformation  

International Nuclear Information System (INIS)

Phase and structural transformations in a multicomponent (5.05 mas.% Mo-4.95V-3.00Cr-3.05Al) metastable #beta#-titanium alloy on aging after plastic deformation are studied using methods of electron microscopy and X-ray diffraction analysis. The alloy is deformed by twinning in a #left brace#332#right brace# system, and even at initial stages the formation of a twin skeleton takes place in the structure, on further loading the deformation of the skeleton is by secondary twinning resulting in a high plasticity of the alloy. On annealing mechanical twins transform into #alpha#-phase - a ductile twin skeleton is replaced by a rigid skeleton of #alpha#-phase plates. The aging enhances the yield strength of the alloy but decreases sharply its plasticity

2004-12-01

160

Structural Response of Marine Sandwich Panels to Uniform ...  

Science.gov (United States)

... Composite sandwich panels with fiber reinforced plastic (FRP) faces and low 3 density foam cores are fast becoming the structural material of ...

1990-06-01

162

Polycarbonate Bottle Use and Urinary Bisphenol A Concentrations  

UK PubMed Central (United Kingdom)

BackgroundBisphenol A (BPA) is a high-production-volume chemical commonly used in the manufacture of polycarbonate plastic. Low-level concentrations of BPA in animals and possibly...Full Text Available

2009-09-01

163

Plasticity in patterns of histone modifications and chromosomal proteins in Drosophila heterochromatin  

UK PubMed Central (United Kingdom)

Eukaryotic genomes are packaged in two basic forms, euchromatin and heterochromatin. We have examined the composition and organization of Drosophila melanogaster heterochromatin in...Full Text Available

2011-02-01

164

Plastic wastes, lube oils and carbochemical products as secondary feedstocks for blast-furnace coke production  

British Library Electronic Table of Contents (United Kingdom)

Two plastic wastes (polyolefin-enriched and multicomponent), two lube oils (paraffinic and synthetic) and one coal-tar were assessed as individual and combined additives to coal blends for the production of blast furnace coke. The effects of adding 2wt.% of these additives or their mixtures (50:50 w/w) on the coking capacity of coal, coking pressure and coke quality parameters were investigated. It was found that the two plastic wastes reduce fluidity, whereas the addition of oils and tar helps to partially restore the fluidity of the coal-plastic blend. From the co-carbonization of the coking blend with the different wastes in a movable wall oven of over 15kg capacity, it was deduced that polyolefins have a detrimental effect on coking pressure. The addition of oils and tar to the coal-pl...

2011-01-01

165

Oral Exposure to Bisphenol A Increases Dimethylbenzanthracene-Induced Mammary Cancer in Rats  

UK PubMed Central (United Kingdom)

BackgroundBisphenol A (BPA) is widely used in the manufacture of polycarbonate plastics, including infant formula bottles.ObjectivesBased on the...Full Text Available

2009-06-01

166

Normal osteoid tissue  

UK PubMed Central (United Kingdom)

The results of a histological study of normal osteoid tissue in man, the monkey, the dog, and the rat, using thin microtome sections of plastic-embedded undecalcified bone, are described. Osteoid tissue...Full Text Available

1972-03-01

167

Evaluation of adhesive bonded sandwich panels for ...  

Science.gov (United States)

... content of the environment) are significant factors affecting the useful service life of adhesive bonded plastic composite sandwich panels at 650 F ...

1970-10-01

169

Development of plasticity processing of magnesium alloys  

Energy Technology Data Exchange (ETDEWEB)

Recent developments on plastic forming technology of magnesium alloys are presented. Attempts have been undergoing with an aim at forming magnesium alloy parts at lower temperatures. It is believed that fine microstructure magnesium alloys usually have much higher plasticity at lower temperatures and even room temperatures. Extrusion is a method to form magnesium profile products and tube products, which is also one of the effective ways to make fine microstructure magnesium alloys. Superplasticity forming is another method to form high plasticity magnesium alloys. Hot forming of magnesium sheet parts is an important process to form magnesium products. Some developments related to above issues are discussed in the present paper. (orig.)

2003-07-01

171

Cold-atmospheric pressure plasma polymerization of acetylene on wood flour for improved wood plastics composites  

Science.gov (United States)

Plastic composites have become a large class of construction material for exterior applications. One of the main disadvantages of wood plastic composites resides in the weak adhesion between the polar and hydrophilic surface of wood and the non-polar and hydrophobic polyolefin matrix, hindering the dispersion of the flour in the polymer matrix. To improve interfacial compatibility wood flour can be pretreated with environmentally friendly methods such as cold-atmospheric pressure plasma. The objective of this work is therefore to evaluate the potential of plasma polymerization of acetylene on wood flour to improve the compatibility with polyolefins. This presentation will describe the reactor design used to modify wood flour using acetylene plasma polymerization. The optimum conditions for plasma polymerization on wood particles will also be presented. Finally preliminary results on the wood flour surface properties and use in wood ...

2009-10-01

173

Cast in Plastic: Semiotic Plasticity and the Pragmatic Reading of Darwin  

British Library Electronic Table of Contents (United Kingdom)

As Darwin portended but failed to develop, and of which Gould made much, the forensic evidence of evolution points toward Punctuated Equilibrium rather than Phyletic Gradualism; however Gould?s empirical postulation has long suffered from its lack of a testable theoretical basis. This is rectified by the work of Jaroslav Flegr and the Frozen Plasticity Theory, a hypothesis with striking application within semiotic theory and hence to questions of epistemology and ontology. The consequences of applying FPT within Biosemiotics is this: when any particular sign carries a great range of interpretation (semiotic polymorphism) combined with a high degree of mutually supportive referencing (semiotic pleiotropy), that sign is less likely to exhibit plasticity?less able to find new expressions capa...

2011-01-01

174

Aphakic macular oedema following prosthetic lens implantation.  

UK PubMed Central (United Kingdom)

Fluorescein angiography of the iris was performed on patients with plastic lens implants with cystoid oedema of the macula, and the nature of the vascular changes was compared with controls provided...Full Text Available

1977-05-01

175

An Investigation of Filled and Plasticized Polyvinyl Chloride,  

Science.gov (United States)

... Personal Author(s) : Tarasenko,Yu. G. ; Venediktov,MV ; Dyshchenko,VP ; Kolupaev,BS. Report Date : 25 AUG 1972. Pagination or Media Count : 16 ...

1972-08-25

176

Advances in feedstock recycling offer help with plastic waste  

Energy Technology Data Exchange (ETDEWEB)

An idea whose time has come takes center stage in London this week when BP Chemicals announces details of a consortium of chemical companies joining it in a new recycling project. In the project, which BP has been working on since 1989, waste plastic will be depolymerized to chemical feedstocks, via technology variously called feedstock or chemical recycling, polymer cracking, or tertiary recycling. BP's effort is one of the first to emerge from the research and pilot-plant stages that are committed to actual feedstock recycling of mixed polyolefins and other plastics. But it is only one of the many industry efforts under way to cope with the job of dealing with postconsumer plastics.

1993-10-04

177

AMPA-receptor trafficking and injury-induced cell death  

UK PubMed Central (United Kingdom)

AMPA receptors (AMPARs) are critical for synaptic plasticity, and are subject to alterations based on subunit composition and receptor trafficking to and from the plasma membrane. One of the...Full Text Available

2010-07-01

178

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

179

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate ...

1988-12-01

180

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

181

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

182

Detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is ...

1991-03-13

183

Conventional detectors for a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).

1995-02-01

184

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

185

Phthalate esters used as plasticizers in packed red blood cell storage bags may lead to progressive toxin exposure and the release of pro-inflammatory cytokines  

UK PubMed Central (United Kingdom)

Phthalate esters (PE's) are plasticizers used to soften PVC-based medical devices. PE's are the most abundant man-made pollutants and increase the risk of developing an allergic respiratory disease...Full Text Available

2009-07-01

186

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

187

Economic impact analysis of proposed effluent limitations and standards for the plastics molding and forming industry  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study is to analyze the economic impact which could result from the application of effluent limitations guidelines and standards issued under Sections 301, 304, 306, 307, 308, and 501 of the Clean Water Act to the plastics molding and forming industry.

1984-02-01

188

Ecobalance of thermoplastic materials. El balance medioambiental de los productos termoplasticos  

Energy Technology Data Exchange (ETDEWEB)

The creation of a methodology about the Ecobalance of the main plastic materials manufactured in Europe is very helpful for many questions relating with these matters. This methodology is necessary for the EC and most of its members. It is important that these analysis have available, precise and up-to-date information. In order that these dates are well-known, the european industry of plastics recognised and started an ambitious project two years ago and now we can see the first results.

1994-01-01

189

Automated analysis of damages for radiation in plastics surfaces; Analisis automatizado de danos por radiacion en superficies plasticas  

Energy Technology Data Exchange (ETDEWEB)

Analysis of damages done by the radiation in a polymer characterized by optic properties of polished surfaces, of uniformity and chemical resistance that the acrylic; resistant until the 150 centigrade grades of temperature, and with an approximate weight of half of the glass. An objective of this work is the development of a method that analyze in automated form the superficial damages induced by radiation in plastic materials means an images analyst. (Author)

1990-02-15

190

Autologous Platelet-Rich Plasma Mixed with Purified Fat Graft in Aesthetic Plastic Surgery  

British Library Electronic Table of Contents (United Kingdom)

Platelet-rich plasma (PRP) is a platelet concentrate that has widely been used to accelerate the healing of soft and hard tissues. The preparation of PRP has been described by several authors. Preparation protocols vary from system to system, depending on the concentration of different integrating proteins. The objective of this article is to describe the principal use of PRP mixed with fat grafts in aesthetic plastic surgery.

2009-01-01

191

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

192

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

193

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

194

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

195

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

196

GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector  

Science.gov (United States)

We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon

2007-01-01

197

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

199

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

200

Advances in imaging THGEM-based detectors  

International Nuclear Information System (INIS)

We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.

2007-03-01

201

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

202

Today`s issues and future scopes concerning recycle of plastic articles; Plastic recycle mondai no genjo to shorai tenbo  

Energy Technology Data Exchange (ETDEWEB)

For reduction of the amount of waste plastics, the paper summarized the actual recycling state and the present recycling technology in Japan. A total plastic discharge amount of Japan in 1995 is 8.84 million tons, approximately 60% of all the production amount, 950,000 tons of which are recycled. Reutilized are pallets and containers in the physical distribution field. Recycling is a cascade recycling to the usage field where the degree of the required properties is lower than that of products used in virgin. As to making it a chemical material, chemical recycling technology by depolymerization has been developed. Thermal recycling is a strong method where combustion heat energy of waste plastics is used for steam production and power generation. The thermal recycling is divided into a direct combustion method and a method of use as fuel. Keys to promote and settle recycling are summarized to the following five: promotion ...

1997-10-10

203

Radiation processing of wood-plastic composites  

International Nuclear Information System (INIS)

There are three main types of radiation-processed composite material derived from plastics and fibrous natural polymers. The first are the monomer-impregnated, radiation-treated wood-plastic composites (WPC). They became a commercial success in the early 1970s. More recently, work has focused on improving the WPCs by creating in them interpenetrating network (IPN) systems by the use of appropriate multifunctional oligomers and monomers. The main kinetic features of radiation-initiated chain polymerization remain applicable even in impregnated wood. The second type are the plastics filled or reinforced with dispersed wood fiber or other cellulosics (WFRP). In their case, radiation processing offers a new opportunity to apply radiation-reactive adhesion promoters between wood or cellulosic fibers and the thermoplastic matrices. The third type are the laminar composites made by electron beam coating of wood-based agglomerate ...

204

Plastic zone and pileup around large indentations  

International Nuclear Information System (INIS)

Mechanical properties of cold-worked molybdenum, grade 4 titanium, and an #alpha#-#beta# titanium alloy are measured with tensile tests and by indentations using conical indenters with 105, 120, and 137 deg included angles. The extent of plastic deformation and pileup around an indentation is measured using profilometry. Various models predicting the extent of plastic deformation and pileup are compared to the actual measured values. As inferred from indentation, the calculated yield strength of the material from the mean pressure does not correlate well to the yield strength measured by tensile testing. The plastic zone size surrounding an indentation can also be used to determine the yield strength of the material, and this does correlate to the yield strength measured by tensile tests. Furthermore, the extent of plastic deformation is relatively independent of the included angle of the indenter for ...

205

Hydrogen-plasticity interactions in pearlitic steel: a fractographic and numerical study  

Energy Technology Data Exchange (ETDEWEB)

A fractographic and numerical approach is presented to analyze hydrogen-plasticity interactions in pearlitic steel and to elucidate the main hydrogen transport mechanism in this material under triaxial stress states produced by notches. Fractographic analysis showed that the microdamage produced by the hydrogen was clearly detectable by scanning electron microscopy (SEM), through a specific microscopic topography associated with hydrogen effects (tearing topography surface or TTS). Numerical computations obtained by using an elastic-plastic finite element program gave the progressive spreading of the plastic zone, closely associated with the movement of dislocations. In the majority of cases, the plastic zone (PZ) clearly exceeds the hydrogen affected region (TTS) and has no relation with it. In some tests, however, the hydrogen-induced micro-damage surpasses the only region in which there is ...

1996-11-30

206

Composites from recycled wood and plastics. Report for May 1990-July 1993  

Energy Technology Data Exchange (ETDEWEB)

The ultimate goal of this research was to develop technology to convert recycled wood fiber and plastics into durable products that are recyclable and otherwise environmentally friendly. Two processing technologies were used to prepare wood-plastic composites: air-laying and melt-blending. Research was conducted in (1) developing laboratory methods for converting waste wood, wastepaper, and waste plastics into forms suitable for processing into composites; (2) optimizing laboratory methods for making composite panels from the waste materials; (3) establishing a database on the effects of formulation and bonding agent on physical and mechanical properties of composites; (4) establishing the extent to which the composites can be recycled without unacceptable loss in properties; and (5) reaching out to industry to provide education, to develop applications, and to extend the database. Overall, the program demonstrated that ...

1995-01-01

207

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

208

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

209

Position detector design using an electrostatic application of ANSYS[sup TM  

Energy Technology Data Exchange (ETDEWEB)

The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.

1994-10-10

210

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

211

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

212

Fundamental understanding of aging processes Review of the workshop results  

CERN Document Server

A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.

2003-01-01

213

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

214

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

215

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

216

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum ...

2004-12-07

217

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the ...

2009-07-23

218

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

219

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

220

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

221

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

222

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

223

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

224

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

1991-09-01

225

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

226

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

227

A Detector for 2-D Neutron Imaging for the Spallation Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)

2006-07-01

228

Recent Korean R&D in Satellite Communications  

Science.gov (United States)

The R&D in satellite communications in Korea has been driven mainly by KCC (Korea Communications Commission) but in a small scale compared to Korea space development program organized by MEST (Ministry of Education, Science and Technology). Public and civilian satcom sector R&D has been led mainly by ETRI with small/medium companies contrary to rare investment in private sector while military sector R&D has been orchestrated by ADD with defense industry. By the COMS (Communication, Ocean and Meteorological Satellite) experimental Ka-band payload, Korea pursues a space qualification of own technology for national infrastructure evolution as well as industrialization of space R&D results. Once COMS launched and space qualified in 2009, subsequent application experiments and new technology R&D like UHDTV will entail service and industry promotion. The payload technology is expected for the next Korean commercial satellites or for new OBP satellites. The COMS ground ...

2009-01-01

229

Geophex Airborne Unmanned Survey System (GAUSS). Topical report, October 1993--September 1996  

Energy Technology Data Exchange (ETDEWEB)

This document is a Final Technical Report that describes the results of the Geophex Airborne Unmanned Survey System (GAUSS) research project. The objectives were to construct a geophysical data acquisition system that uses a remotely operated unmanned aerial vehicle (UAV) and to evaluate its effectiveness for characterization of hazardous environmental sites. The GAUSS is a data acquisition system that mitigates the potential risk to personnel during geophysical characterization of hazardous or radioactive sites. The fundamental basis of the GAUSS is as follows: (1) an unmanned survey vehicle carries geophysical sensors into a hazardous location, (2) the pilot remains outside the hazardous site and operates the vehicle using radio control, (3) geophysical measurements and their spatial locations are processed by an automated data-acquisition system which displays data on an off-site monitor in real-time, and (4) the pilot uses the display to direct the survey vehicle for complete site ...

1998-12-31

230

Neutron detector counting capabilities for /sup 10/B-lined and /sup 235/U fission chambers in high gamma-ray fluxes  

Energy Technology Data Exchange (ETDEWEB)

This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...

1985-03-01

231

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...

1992-10-01

232

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...

2004-01-01

233

Surface damage of mold steel and its influence on surface roughness of injection molded plastic parts  

British Library Electronic Table of Contents (United Kingdom)

Plastic injection molds are an important economic sector due to the increasing use of injection molded plastic components. The selection of mold steel material, its processing conditions, and the way it is machined and hardened all have an impact on how it performs during use across its lifecycle for injection molding. For this study, injection molding conditions seen during high volume manufacturing were used to induce wear that would be typical during processing. A 50wt.% glass fiber reinforced Polybutylene Terephthalate (PBT) was used for the research. After 3000 injection operations, surface damage was found only on the steel used for the stationary half of the mold cavity and the corresponding surface of the molded parts. In contrast, the moving half showed no surface damage or increa...

2011-01-01

234

Study on dechlorination technology for municipal waste plastics containing polyvinyl chloride and polyethylene terephthalate  

British Library Electronic Table of Contents (United Kingdom)

It is necessary to remove chlorine efficiently from municipal waste plastics (MWP) that contain polyvinyl chloride (PVC) and other plastics containing chlorine. In this article we consider thermal degradation liquefaction technology. In Japan, the chlorine content of reclamation oil products must be kept below 100 ppm owing to the quality standard for pyrolysis oil. Liquefaction dechlorination technology for MWP is still an important issue to study. The twin-screw extruder that has been developed as dechlorination technology for blast furnaces and coke ovens has a shorter residence time for dechlorination than other dechlorination technologies. In this article, we used a single-screw extruder for the dechlorination process because it also has a short residence time. Experiments on the dech...

2010-01-01

235

Possible preparation of wood-plastic composites based on unsaturated polyester resins and styrene by radiation and chemical methods in combination  

Energy Technology Data Exchange (ETDEWEB)

Using the radiation chemical method it is possible to prepare wood-plastic composites using doses of 1 to 2.5 kGy. The impregnation mixture in the wood gelatinates and subsequent curing using chemical initiators takes place without outflow of the mixture from the wood and without formation of incrustations. The basic components of the impregnation mixtures used were unsaturated polyester resins; styrene or methyl methacrylate was used as the thinner. The proven initiator of polymerization was 2,2'-azobisisobutyronitrile. The technology is described of wood impregnation and radiation or chemical curing. The effects were monitored of viscosity, temperature, radiation dose and the concentrations of the individual components of the impregnation mixtures and initiators of polymerization on the process of the preparation of wood-plastic composites.

1983-06-01

236

Physical modeling of desiccation cracking in plastic soils  

British Library Electronic Table of Contents (United Kingdom)

Desiccation cracking is a common phenomenon in clay materials, which may considerably increase the hydraulic conductivity of soil. This issue is one of the main concerns in the design and construction of landfill covers, especially, in arid regions. For some highly plastic soils, permeability increases during cyclic drying and wetting are not significant, even though cracking may clearly be noticed in the soil. These cracks may self-heal during subsequent wetting and saturation processes. In the present study, large scale experimental models of various natural clayey soils with various plasticity indices were subjected to cyclic drying and wetting and hydraulic conductivity testing to better understand cracking behaviour and self-healing in fine-grained soils. The soils are candidate clay ...

2008-01-01

237

Photosynthetic consequences of phenotypic plasticity in response to submergence: Rumex palustris as a case study  

British Library Electronic Table of Contents (United Kingdom)

Survival and growth of terrestrial plants is negatively affected by complete submergence. This is mainly the result of hampered gas exchange between plants and their environment, since gas diffusion is severely reduced in water compared with air, resulting in O2 deficits which limit aerobic respiration. The continuation of photosynthesis could probably alleviate submergence-stress in terrestrial plants, but its potential under water will be limited as the availability of CO2 is hampered. Several submerged terrestrial plant species, however, express plastic responses of the shoot which may reduce gas diffusion resistance and enhance benefits from underwater photosynthesis. In particular, the plasticity of the flooding-tolerant terrestrial species Rumex palustris turned out to be remarkable,...

2006-01-01

238

Experimental evidence for intraplate deformation controlled by netlike plastic-flow in central-eastern Asia  

British Library Electronic Table of Contents (United Kingdom)

The experimental results of brittle/ductile two-layer analogue models verify that intraplate tectonic deformation in central-eastern Asia is controlled mainly by the netlike plastic-flow (NPF) occurring in the lower lithosphere, including the lower crust and lithospheric mantle. The ductile lower layer in the model, corresponding to the lower lithosphere in the natural prototype, is made of a mixture of gum rosin and turpentine oil and the brittle upper one, to the upper crust, is formed by the consolidation of talc-powder slurry. The NPF hypothesis for continental dynamics can be regarded as a combination and development of two kinds of seemingly mutually exclusive ones, which are based on the theories of slip-line field and viscous (plastic) flow, respectively. In contrast to "homogeneou...

2007-01-01

239

Elastodynamics of vehicles and crash simulation  

Energy Technology Data Exchange (ETDEWEB)

Accidents of free-rolling cars against walls with friction are special cases of the general problem of the dynamic behavior (elastic or plastic) of car motion. Using particle modeling of the car body it is shown that large rotations, contact friction and plastic deformations can be computed. Because of the limitations of FEM it is necessary to model the car as a system of mass points connected by central force systems which are non-linear. The wall is formulated as a rigid body producing constraints for the contacting particles, while the contact force is given by the defined force system. Every contacting particle produces a plastic impact on the wall. The friction force is proportional to the contact force and lies in the direction of the sliding velocity on the wall. Time integration is carried out using a second order Gear method. ((orig.))

1994-09-30

240

Time-Dependent Expression of Arc and Zif268 after Acquisition of Fear Conditioning  

UK PubMed Central (United Kingdom)

Memory consolidation requires transcription and translation of new protein. Arc, an effector immediate early gene, and zif268, a regulatory transcription factor, have been implicated in synaptic plasticity...Full Text Available

2010-01-01

241

The olympic brain. Does corticospinal plasticity play a role in acquisition of skills required for high-performance sports?  

UK PubMed Central (United Kingdom)

Non-invasive electrophysiological and imaging techniques have recently made investigation of the intact behaving human brain possible. One of the most intriguing new research areas that have developed...Full Text Available

2008-01-01

242

The Use of Self-Expanding Plastic Stents in the Management of Oesophageal Leaks and Spontaneous Oesophageal Perforations  

UK PubMed Central (United Kingdom)

Leakage after oesophageal anastomosis or perforation remains a challenge for the surgeon. Traditional management has been operative repair or intensive conservative management. Both treatments are...Full Text Available

2011-01-01

243

Synchrony between orientation-selective neurons is modulated during adaptation-induced plasticity in cat visual cortex  

UK PubMed Central (United Kingdom)

BackgroundVisual neurons respond essentially to luminance variations occurring within their receptive fields. In primary visual cortex, each neuron is a filter for stimulus features...Full Text Available

244

Synapse-Associated Protein 102/dlgh3 Couples the NMDA Receptor to Specific Plasticity Pathways and Learning Strategies  

UK PubMed Central (United Kingdom)

Understanding the mechanisms whereby information encoded within patterns of action potentials is deciphered by neurons is central to cognitive psychology. The multiprotein complexes formed by...Full Text Available

2007-03-07

245

Social competition affects electric signal plasticity and steroid levels in the gymnotiform fish Brachyhypopomus gauderio  

UK PubMed Central (United Kingdom)

Sexually-selected communication signals can be used by competing males to settle contests without incurring the costs of fighting. Steroid regulation of these signals can render them as reliable...Full Text Available

2009-10-01

246

Respiratory morbidity of pattern and model makers exposed to wood, plastic, and metal products  

Energy Technology Data Exchange (ETDEWEB)

Pattern and model makers are skilled tradespersons who may be exposed to hardwoods, softwoods, phenol-formaldehyde resin-impregnated woods, epoxy and polyester/styrene resin systems, and welding and metal-casting fumes. The relationship of respiratory symptoms (wheezing, chronic bronchitis, dyspnea) and pulmonary function (FVC% predicted, FEV1% predicted, FEV1/FVC% predicted) with interview-derived cumulative exposure estimates to specific workplace agents and to all work with wood, plastic, or metal products was investigated in 751 pattern and model makers in southeast Michigan. In stratified analyses and age- and smoking-adjusted linear and logistic regression models, measures of cumulative wood exposures were associated with decrements in pulmonary function and dyspnea, but not with other symptoms. In similar analyses, measures of cumulative plastic exposures were associated with wheezing, chronic bronchitis, and dyspnea, but not with ...

1990-01-01

247

Plasticity of the cochleotopic (frequency) map in specialized and nonspecialized auditory cortices  

UK PubMed Central (United Kingdom)

Auditory conditioning (associative learning) causes reorganization of the cochleotopic (frequency) maps of the primary auditory cortex (AI) and the inferior colliculus. Focal electric stimulation...Full Text Available

2001-03-13

248

Physical Morphology and Quantitative Characterization of Chemical Changes of Weathered PVC/Pine Composites.  

Science.gov (United States)

This study investigated weathering effects on polyvinyl chloride (PVC) based wood plastic composites (WPC), with a focus on the color and structure that is attributed to the material composition. It is directed towards quantifying the main chemical modifi...

2009-01-01

249

On-line plasticity in spoken sentence comprehension: Adapting to time-compressed speech  

UK PubMed Central (United Kingdom)

AbstractListeners show remarkable flexibility in processing variation in speech signal. One striking example is the ease with which they adapt to novel speech distortions such as listening...Full Text Available

2010-01-01

250

Oligodendrocyte-Myelin Glycoprotein and Nogo Negatively Regulate Activity-Dependent Synaptic Plasticity  

UK PubMed Central (United Kingdom)

In the adult mammalian CNS, the growth inhibitors oligodendrocyte-myelin glycoprotein (OMgp) and the reticulon RTN4 (Nogo) are broadly expressed in oligodendrocytes and neurons. Nogo and OMgp...Full Text Available

2010-09-15

251

New Pathogenicity Marker Found in the Plasticity Region of the Helicobacter pylori Genome  

UK PubMed Central (United Kingdom)

Comparison of gastric carcinoma and gastritis isolates showed the presence of genes, probably carcinoma associated (JHP947 and JHP940), that are situated in a Helicobacter...Full Text Available

2003-04-01

252

Name of Presentation!  

Wastenet

Up-flow anaerobic attached-growth bioreactors filled with pre-treated coir fibres ...coir-fibre arranged in bottle-brush configuration bounded by a novel plastic binding technique ...-three anaerobic filter reactors in series -coir fibre as the bacteria growth media a sedimentation

253

Modification of the sheet resistance of ink jet printed polymer conducting films by changing the plastic substrate  

Energy Technology Data Exchange (ETDEWEB)

The ink jet printing technology is a relatively novel technique in development of organic electronic devices. The technique consists of working out depositions of organic layers by a piezo-based ink jet printer. In this work polymer conducting films deposited by ink jet printing technique on different plastic substrates has been demonstrated. The poly(3,4-ethylenedioxythiofene)/poly(4-styrenesulfonate) [PEDOT/PSS] and glycerol-modified PEDOT/PSS [G-PEDOT/PSS] were used like conducting inks to be applied on polyester and polyethylene terephthalate (PET) substrates. By means of the change of substrate associated to the deposition number or type of polymer ink used for printing of the conducting films, the sheet resistance can be modified. Such a behavior suggests that plastic substrate fulfills an important role for the changing of sheet resistance of the PEDOT/PSS and G-PEDOT/PSS films made by ink jet printing technique. Films obtained from this ...

2005-09-25

254

Mild salinity stimulates a stress-induced morphogenic response in Arabidopsis thaliana roots  

UK PubMed Central (United Kingdom)

Plant roots exhibit remarkable developmental plasticity in response to local soil conditions. It is shown here that mild salt stress stimulates a stress-induced morphogenic response (SIMR) in Arabidopsis...Full Text Available

2010-01-01

255

Micromechanical characterization tools for highly-filled polymers  

Energy Technology Data Exchange (ETDEWEB)

We are attempting to characterize and model the micromechanical response of highly-filled polymers. In this class of materials, the continuous plastic binder used to bond the highly-filled material dominates the observed viscoelastic response. As a result, realistic lifetime analysis of these materials will require a thorough understanding of the contribution of the plastic binder. Laboratory applications of these materials include plastic bonded explosives, propellants, a variety of specialized filled organic materials for stockpile systems, and highly filled epoxy dielectric materials for the National Ignition Facility. We have explored numerous techniques to characterize the local microstructure of plastic bonded explosives. However, insufficient funding was obtained to bring these technologies to maturity, nevertheless our present tool set is significantly better than 2 years ago. We have also made ...

2000-02-16

256

Manufacture of wood/plastic composites by radiation  

International Nuclear Information System (INIS)

The manufacture and use of wood/plastic composite (WPC) as an example of wood matrix and wood sawdust/plastic composites (SDP) as an example of plastic matrix are reviewed. The raw material for WPC are mostly vinyl monomers, particularly methyl methacrylate and styrene. The reaction in WPC polymerization is radical polymerization. Researches on the radiation sources mostly resulted in gamma-ray. Electron beam can be applied only to thin products. The future use of WPC may be for furnitures, sporting goods, decorative parts and the like. Vital study on the reduction of manufacturing costs is required, for example, the improvement of reaction and the adoption of continuous process must be considered. The raw materials for SDP are wood sawdust, vinyl monomer (mostly methyl methacrylate) and resins. Electron beam accelerators are the most preferable radiation source because of its high efficiency and safe operation. SDP shows ...

1976-01-01

257

Long-term cortical plasticity evoked by electric stimulation and acetylcholine applied to the auditory cortex  

UK PubMed Central (United Kingdom)

Auditory fear conditioning with tone bursts followed by electric leg stimulation activates neurons not only in the auditory and somatosensory systems but also in many other regions of the brain and...Full Text Available

2005-06-28

258

Life history plasticity after attaining a dietary threshold for reproduction is associated with protein storage in flesh flies  

UK PubMed Central (United Kingdom)

SummaryBody condition affects the timing and magnitude of life history transitions. Therefore, identifying proximate mechanisms...Full Text Available

2008-12-01

259

Intrinsic plasticity complements LTP in parallel fiber input gain control in cerebellar Purkinje cells  

UK PubMed Central (United Kingdom)

Synaptic gain control and information storage in neural networks are mediated by alterations in synaptic transmission, such as in long-term potentiation (LTP). Here, we show using both in...Full Text Available

2010-10-13

260

Insights into Genome Plasticity and Pathogenicity of the Plant Pathogenic Bacterium Xanthomonas campestris pv. vesicatoria Revealed by the Complete Genome Sequence  

UK PubMed Central (United Kingdom)

The gram-negative plant-pathogenic bacterium Xanthomonas campestris pv. vesicatoria is the causative agent of bacterial spot disease in pepper and tomato plants, which leads to economically...Full Text Available

2005-11-01

261

Indentation plastic displacement field: Part II. The case of hard films on soft substrates  

Energy Technology Data Exchange (ETDEWEB)

The plastic displacements around Knoop indentations made in hard titanium/aluminum multilayered films on soft aluminum alloy substrates have been studied. Indentations were cross-sectioned and imaged using the focused-ion-beam (FIB) milling and high-resolution scanning electron microscopy (SEM), respectively. The FIB milling method has the advantage of removing material in a localized region without producing mechanical damage to the specimen. The micrographs of the cross-sectioned indentations indicate that most of the plastic deformation around the indentation is dominated by the soft aluminum substrate. There is a very small change in the multilayered film thickness around the indentation{emdash}less than 10{percent}. The plastic deformation of the thin film resembles a membrane being deflected by a localized pressure gradient across the membrane. Stress-induced voids are also observed in the multilayered film, ...

1999-06-01

262

Health hazards in the production and processing of some fibers, resins, and plastics in Bulgaria.  

UK PubMed Central (United Kingdom)

Results of the toxicological studies of working conditions, general and professional morbidity, and complex examinations carried out on workers engaged in the production of polyamides, polyacrylonitrile...Full Text Available

1976-10-01

263

Emotional enhancement of memory: how norepinephrine enables synaptic plasticity  

UK PubMed Central (United Kingdom)

Changes in synaptic strength are believed to underlie learning and memory. We explore the idea that norepinephrine is an essential modulator of memory through its ability to regulate synaptic mechanisms....Full Text Available

264

Effect of Particle Size on Compaction of Materials with Different Deformation Mechanisms with and without Lubricants  

UK PubMed Central (United Kingdom)

This work investigates the effect of excipient particle size on compaction properties of brittle, plastic and viscoelastic materials with and without added lubricants. Sieve cuts of Microcrystalline...Full Text Available

265

Downregulation of Serum Gonadotropins is as Effective as Estrogen Replacement at Improving Menopause-Associated Cognitive Deficits  

UK PubMed Central (United Kingdom)

While estrogen (E2) is thought to play an important role in age-related cognitive decline, neuronal plasticity, as well as the pathogenesis of Alzheimer disease (AD), the mechanisms by which...Full Text Available

2010-02-01

266

Developmental plasticity and the evolution of animal complex life cycles  

UK PubMed Central (United Kingdom)

Metazoan life cycles can be complex in different ways. A number of diverse phenotypes and reproductive events can sequentially occur along the cycle, and at certain stages a variety of developmental...Full Text Available

2010-02-27

267

Cracking resistance in steam pipe fittings having various microdamage levels  

Energy Technology Data Exchange (ETDEWEB)

Cracking resistance and metal damage are considered in relation to structural state for steam-pipe fittings during use. An approximate scheme is given for estimating the maximum permissible operating time in the plastic state in relation to the depth of an observed crack-type defect.

1995-05-01

268

Consideration of radiation effects in the choice of packaging materials  

International Nuclear Information System (INIS)

Requirements for food packaging materials include whether there is any interaction between the food and the package during or after the irradiation, and whether as a result of the irradiation, volatile or leachable substances are released from the pack into the food. The performance of cellulose-based materials and plastic films under irradiation are discussed.

269

Calcium/Calmodulin-Dependent Protein Kinase II Mediates Hippocampal Glutamatergic Plasticity During Benzodiazepine Withdrawal  

UK PubMed Central (United Kingdom)

Benzodiazepine withdrawal anxiety is associated with potentiation of α-amino-3-hydroxy-5-methyl-4-isoxazolepropionate receptor (AMPAR) currents in hippocampal CA1 pyramidal...Full Text Available

2010-08-01

270

Association of Protein Phosphatase 1?1 with Spinophilin Suppresses Phosphatase Activity in a Parkinson Disease Model*  

UK PubMed Central (United Kingdom)

Sustained nigrostriatal dopamine depletion increases the serine/threonine phosphorylation of multiple striatal proteins that play a role in corticostriatal synaptic plasticity, including Thr286...Full Text Available

2008-05-23

271

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

272

Adult-born hippocampal neurons are more numerous, faster-maturing and more involved in behavior in rats than in mice  

UK PubMed Central (United Kingdom)

Neurons are born throughout adulthood in the hippocampus and show enhanced plasticity compared to mature neurons. However, there are conflicting reports on whether or not young neurons contribute...Full Text Available

2009-11-18

273

Adaptive plasticity of mammalian sperm production in response to social experience  

UK PubMed Central (United Kingdom)

Sperm competition theory predicts that males should invest prudently in ejaculates according to levels of female promiscuity. Males may therefore be sensitive to cues in their social environment associated...Full Text Available

2009-02-22

274

Wood plastic composite at different urea concentrations  

Energy Technology Data Exchange (ETDEWEB)

Wood plastic composite (WPC) has been prepared with a low grade wood simul (Salmalia malabarica) of Bangladesh under Co-60 gamma irradiation using MMA as the bulk monomer combined with methanol as the swelling solvent at different urea concentrations. Effect of a second solute such as NVP, TPGDA and TMPTA in the impregnating solution is evaluated. NVP appears to be the best co-additive/second solute among all the additives used to yield the composite with the highest polymer loading (PL) and tensile strength (TS) at 0.5% urea concentration. (author).

1995-04-01

275

Wood plastic composite at different urea concentrations  

International Nuclear Information System (INIS)

Wood plastic composite (WPC) has been prepared with a low grade wood simul (Salmalia malabarica) of Bangladesh under Co-60 gamma irradiation using MMA as the bulk monomer combined with methanol as the swelling solvent at different urea concentrations. Effect of a second solute such as NVP, TPGDA and TMPTA in the impregnating solution is evaluated. NVP appears to be the best co-additive/second solute among all the additives used to yield the composite with the highest polymer loading (PL) and tensile strength (TS) at 0.5% urea concentration. (author).

1995-01-01

276

The evolution of rigid-plastic dynamic response by mathematical programming  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a systematic approach to the automatic determination of the evolution of the rigid-plastic structural response caused by a proportional or single parameter pressure loading which varies with time in a monotonic non decreasing fashion. The frame structure is envisaged as a network, and the fundamental vectorial conditions characterising its behaviour at any instant of time are combined in a consistent manner. By considering the level of the pressure loading to be a single load parameter ranging monotonically from zero to infinity, the structural governing system may be regarded as a parametric linear complementary problem. (author). 13 refs., 2 figs.

1995-12-31

277

The effects of gamma irradiation of food contact plastics on the extent of migration of hindered phenol antioxidants into fatty food simulants  

International Nuclear Information System (INIS)

In view of the interest in the use of gamma irradiation to extend the storage life of pre-packaged foods a report is made on the effects of gamma radiation on the migration of Irganox 1076 and Irganox 1010, antioxidants present in food packaging plastics, into synthetic triglyceride fatty-food simulant HB307 and iso-octane. The extent of migration was assayed by h.p.l.c. techniques. Migration into HB307 and iso-octane decreased steadily as irradiation progressed suggesting that gamma irradiation of packaging materials helps to prevent the contamination of food by antioxidants in the packaging. (U.K.).

278

Synergistic yields in the wood plastic composites  

Energy Technology Data Exchange (ETDEWEB)

Wood plastic composites formation has been studied with simul (soft wood, density = 0.4 g/cm{sup 3}) and butylmethacrylate (BA) monomer using 10% methanol as the swelling agent. The effect of additives like sulfuric acid, multifunctional monomers (NVP, TPGDA, TMPTA) and oligomers (PEA, UA and EA) has been investigated using 1-3 Mrad dose at 0.8 Mrad/h. Synergistic polymer yields have been achieved in presence of the additives. The tensile properties of the composite are also reported. (author).

1991-01-01

279

Structural integrity of whipping pipes following a postulated circumferential break - a contribution to determining strain levels acceptable under faulted conditions  

Energy Technology Data Exchange (ETDEWEB)

It is postulated that a break of a thin-walled pipe does not cause a subsequent break in the pipe in the vicinity of a plastic hinge even when the wall is weakened by a 60 circumferential crack of a depth of 30% of the wall thickness on the tension side. This pipe behavior is the result of plastic buckling in the compression side and applies to pipes of diameter-to-thickness ratio larger than 20. For this type of pipe, the axial strains decrease with increasing diameter-to-thickness ratio in the tension side. As the pipe is only loaded in one direction, there is no cyclic behavior that can trigger a subsequent break. (orig.)

1993-10-01

280

Stability of model recycled mixed plastic waste compatibilised with a cooperative compatibilisation system  

British Library Electronic Table of Contents (United Kingdom)

The effect of the degree of degradation of the components of a model municipal plastic waste (a mixture of low-density polyethylene, high-density polyethylene, polypropylene and high-impact polystyrene) on the toughness and stability of recyclates compatibilised with a cooperative compatibilisation system (a mixture of ethylene-propylene statistical and styrene-butadiene block copolymers with a secondary amine-based stabiliser) was studied. It was shown that good impact strength was achieved for recyclates having components with a low or medium degree of degradation. Mechanical properties of recyclates having the components with a high degree of degradation are deteriorated. The addition of the cooperative compatibilisation system leads to a higher thermo-oxidative stability of recyclates ...

2011-01-01

281

Recycling of PTFE by means of ionizing rays  

International Nuclear Information System (INIS)

By treatment with beta or gamma rays, PTFE waste is converted to high-grade PTFE fine powder. High-molecular weight PTFE is degraded to low-molecular weight PTFE. Due to this the density, the degree of crystallinity, and the melt flow index are increased, which enhances the brittleness of the material. Irradiation of PTFE thus facilitates milling and makes the material pourable and free-flowing. Milled PTFE fine powder, lie PTFE plastic, combines temperature resistance, weather fastness, and chemical stability with good slip behaviour and antiadhesive properties. Areas of application for fine powder include additives for plastics, printing inks, nonstick coatings, and antifriction lacquers. (orig.).

1994-01-01

282

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

283

Polysilicon TFT fabrication on plastic substrates  

Energy Technology Data Exchange (ETDEWEB)

Processing techniques utilizing low temperature depositions and pulsed lasers allow the fabrication of polysilicon thin film transistors (TFT`s) on plastic substrates. By limiting the silicon, SiO2, and aluminum deposition temperatures to 100(degrees)C, and by using pulsed laser crystallization and doping of the silicon, we have demonstrated functioning polysilicon TFT`s fabricated on polyester substrates with channel mobilities of up to 7.5 cm2/V-sec and Ion/Ioff current ratios of up to 1x10(to the 6th power).

1997-08-06

284

Method of the cementing of material  

Energy Technology Data Exchange (ETDEWEB)

Invention relates to woodworking industry and concerns method of cementing of materials of foam plastic with duralumin, glued plywood, etc. Known methods of cementing of materials by effect of electromagnetic field of superhigh frequencies are unproductive and do not make it possible to cement parts on the plane. Target of invention - acceleration of process of cementing of planar, including of complex configuration, parts and assemblies from wood, foam plastic, duralumin, glued plywood and other materials. For this material is cemented under the effect of directed electromagnetic field of superhigh frequency in the range 01-50 GHz, the specific power of 0.5-15 W/cm3.

1990-10-30

285

Manufacturing of golf club using wood-plastic combination produced by. gamma. -irradiation  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic combination (WPC) was produced by {gamma}-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).

1992-01-01

286

Manufacturing of golf club using wood-plastic combination produced by #gamma#-irradiation  

International Nuclear Information System (INIS)

Wood-plastic combination (WPC) was produced by #gamma#-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).

1992-01-01

287

Gelcasting compositions having improved drying characteristics and machinability  

Energy Technology Data Exchange (ETDEWEB)

A gelcasting composition has improved drying behavior, machinability and shelf life in the dried and unfired state. The composition includes an inorganic powder, solvent, monomer system soluble in the solvent, an initiator system for polymerizing the monomer system, and a plasticizer soluble in the solvent. Dispersants and other processing aides to control slurry properties can be added. The plasticizer imparts an ability to dry thick section parts, to store samples in the dried state without cracking under conditions of varying relative humidity, and to machine dry gelcast parts without cracking or chipping. A method of making gelcast parts is also disclosed.

2001-01-01

288

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

289

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

290

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)

2002-01-01

291

Effect of urea on the mechanical strength of wood-plastic composites  

Energy Technology Data Exchange (ETDEWEB)

The effect of additives on the grafting of a monomer, butylmethacrylate (BA), into simul (a soft wood) has been studied using {sup 60}Co source at 3 Mrad. The enhancement of polymer loading (grafting) by the addition of minute amounts (1%) of oligomers and of polyfunctional monomers into simul + BA system has been further increased in the presence of acid and urea. The synergistic polymer loading yields by acid addition cause substantial decrease of tensile strength values of wood-plastic composite; but urea increases both polymer loading and tensile strength values synergistically in these systems. (author).

1992-07-01

292

Effect of urea on the mechanical strength of wood-plastic composites  

International Nuclear Information System (INIS)

The effect of additives on the grafting of a monomer, butylmethacrylate (BA), into simul (a soft wood) has been studied using "6"0Co source at 3 Mrad. The enhancement of polymer loading (grafting) by the addition of minute amounts (1%) of oligomers and of polyfunctional monomers into simul + BA system has been further increased in the presence of acid and urea. The synergistic polymer loading yields by acid addition cause substantial decrease of tensile strength values of wood-plastic composite; but urea increases both polymer loading and tensile strength values synergistically in these systems. (author).

1992-01-01

293

Consolidation behavior of Cu- and Ni-based bulk metallic glass composites  

Energy Technology Data Exchange (ETDEWEB)

The Cu- and Ni-based bulk metallic glass matrix composites were fabricated by spark plasma sintering of a mixture of gas-atomized metallic glass powders and ductile brass powders. The brass powders added for the enhancement of plasticity are well distributed in the matrix after consolidation. The matrix of the composite materials remains as a fully amorphous phase after consolidation process. With increasing the brass content, the level of plasticity strain increased, although the level of strength decreased. The successful consolidation of metallic glass matrix composite with high density was attributed to viscous flow in the supercooled liquid state during spark plasma sintering.

2007-05-31

294

Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector  

Energy Technology Data Exchange (ETDEWEB)

The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with ...

2006-07-01

295

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics ...

2000-01-01

296

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...

1997-02-01

297

Electronics for the Si detectors in APEX  

Energy Technology Data Exchange (ETDEWEB)

APEX (ATLAS Positron EXperiment), a collaborative effort of ANL, FSU, MSU/NSCL, Princeton, Queen`s, Rochester, Washington and Yale, is an experiment to study positron and electron production in very heavy ion collisions. The electrons and positrons are detected with two detector arrays, each consisting of 216 1 mm thick Si PIN diodes, and their energy and time-of-flight are measured. The number of detectors and limited space made it necessary to develop a system that could efficiently process and transfer signals from the detectors to the charge sensing ADC`s and data readout electronics as well as monitor the condition of the detectors. The discussion will cover the electronics designed for the Si detectors, including the charge amplifier, ``Mother board`` for the charge amplifiers, 8 channel Shaper, 16 channel Constant Fraction Discriminator (CFD), 16 channel Peak-to-FERA (PTF) ...

1994-07-01

298

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the ...

299

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties ...

2007-06-11

300

The hunt for ?13 at the Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.

2010-03-30

301

The cross-coupled interferometer for gravitational wave detection  

International Nuclear Information System (INIS)

The cross-coupled interferometer is a new design for interferometric gravitational wave detectors. Similar to the baseline gravitational wave detectors proposed for Advanced LIGO, it uses long-arm cavities in which the signal is generated. The signal fields are then extracted from the arm cavities with an additional cavity behind the long-arm cavities. The tuning of this signal extraction cavity and the parallel tuning of the signal recycling mirror can be used to optimize the peak frequency and the bandwidth of the detector independently. If we replace the signal recycling mirror by a small cavity, it is possible to amplify signals in two different frequency bands.

2002-04-07

302

Tests with superconducting re-entrant cavities for transducer applications in gravitational wave detectors  

International Nuclear Information System (INIS)

We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.

2004-03-07

303

Sudbury neutrino detector  

International Nuclear Information System (INIS)

The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.

304

Studies of a Poenitz-type black neutron detector as a neutron flux monitor  

Energy Technology Data Exchange (ETDEWEB)

A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).

1997-04-01

305

Silicon Detector Letter of Intent  

Energy Technology Data Exchange (ETDEWEB)

This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.

2010-05-26

306

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

307

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

308

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

309

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

310

A PDA-Based ECG Beat Detector for Home Cardiac Care.  

Science.gov (United States)

Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192

2005-01-01

311

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

312

The mass dependence of the signal peak height of a Bragg-curve ionization chamber  

International Nuclear Information System (INIS)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).

313

The CDF intermediate silicon layers detector  

Energy Technology Data Exchange (ETDEWEB)

The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.

1999-11-01

314

The Brazilian Bragg curve detector built for AMS studies  

Energy Technology Data Exchange (ETDEWEB)

A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.

2000-10-01

315

Studies of relativistic heavy ion collisions at the AGS (Experiment 814)  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)

1990-01-01

316

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. ...

2001-01-01

317

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

318

Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information  

International Nuclear Information System (INIS)

The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)

2010-11-01

319

Radon concentration measurements by means of nuclear tracks detector with image analysis  

International Nuclear Information System (INIS)

English 1998 p. 124 Poland Antanasijevic, R. Vukovic, J. Novakovic, V. Tasic,

1998-09-15

320

Photoconductive ultraviolet detectors based on ZnO films  

British Library Electronic Table of Contents (United Kingdom)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...

2006-01-01

321

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

322

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...

2006-10-29

323

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

324

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

325

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through ...

1992-01-01

326

Mass dependence of the signal peak height of a Bragg-curve ionization chamber  

Energy Technology Data Exchange (ETDEWEB)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.

1985-01-01

327

Linewidth-broadened Fabry-Perot cavities within future gravitational wave detectors  

International Nuclear Information System (INIS)

The bandwidth of LIGO-like terrestrial interferometric gravitational wave detectors is set by the pole of the Fabry-Perot cavities within the arms of the Michelson interferometer. This constraint arises because the gain of gravitational wave-induced signal sidebands is limited to frequencies within the linewidth of the cavities. The nature of standard Fabry-Perot cavities is such that one cannot independently adjust for increased gain without suffering a loss of bandwidth. If these quantities could be decoupled, the resulting improvement in bandwidth may lead to viable high frequency detectors. A pair of anti-parallel diffraction gratings within a Fabry-Perot cavity can increase the bandwidth of a LIGO-scale detector by a factor of #approx#1000.

2004-03-07

328

LAMBDA - IRAS Faint Source Survey Plates - LAMBDA - NASA  

Science.gov (United States)

Apr 18, 2008 ... The FSS was produced by point-source filtering the individual detector data ... a 1-sigma noise map; and a coverage map giving the count of ...

329

Intercomparison of Retrospective Radon Detectors  

Energy Technology Data Exchange (ETDEWEB)

We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated measurements using two ...

1998-11-01

330

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in ...

2006-11-13

331

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

332

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-15

333

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-01

334

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

335

DESIGN, IMPLEMENTATION AND TESTING OF ... - LAMBDA - NASA  

Science.gov (United States)

FIG. 4. Power Spectral Density of the MAP W11 radiometer. The red and black traces are the power spectral density measurements of the two detectors on the ...

336

Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid  

CERN Document Server

In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.

1993-01-01

337

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

Energy Technology Data Exchange (ETDEWEB)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

1993-12-31

338

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

International Nuclear Information System (INIS)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

341

Annihilation of antiprotons in light nuclei  

CERN Document Server

CR-39 detectors have been exposed to a 5.9-MeV antiproton beam using the low energy antiproton ring (LEAR) facility at CERN. At this energy, tracks of antiprotons appear in a CR-39 detector after 135 min of etching in 6 M NaOH at 70C. Fluence of the antiproton beam has been determined using track density. We have also found tracks in the etched CR-39 detector at different depths (250-500 mum). These tracks have resulted from the annihilation of antiprotons with the constituents (H, C and O) of the CR-39 detector. The goal of the experiment is to develop a simple and low-cost method to study properties of antiparticles and those formed after annihilation of these particles with the target matter.

2006-01-01

342

AeroSpace Information for a Changing World - NASA Technical ...  

Science.gov (United States)

Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...

343
344

A Quantum-Enhanced Prototype Gravitational-Wave Detector  

CERN Document Server

The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point fluctuations of the electromagnetic field, which constrain the precision with which optical signals can be measured. In the world of precision measurement, laser-interferometric gravitational wave (GW) detectors are the most sensitive position meters ever operated, capable of measuring distance changes on the order of 10^-18 m RMS over kilometer separations caused by GWs from astronomical sources. The sensitivity of currently operational and future GW detectors is limited by quantum optical noise. Here we demonstrate a 44% improvement in displacement sensitivity of a prototype GW detector with suspended quasi-free mirrors at frequencies where the sensitivity is shot-noise-limited, by ...

2008-01-01

345

8 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

feature similar to the face detection in Intel's OpenCV library, implement it in Matlab code, and test the performance of the new ROI detector against the ...

346

PT3. [SITE 2002 Section].  

Science.gov (United States)

This document contains 142 papers on PT3 (Preparing Tomorrow's Teachers to use Technology) from the SITE (Society for Information Technology & Teacher Education) 2002 conference. Topics covered include: a technology in urban education summit; student professional development; meeting NCATE (National Council of Teachers of English) standards; faculty use of WebCT; preparing teachers for the digital age; technology in K-8 multicultural classrooms; using immersive 360 degree images; consortium building; student evaluation; technology fellows; incentives that facilitate institutional change; impact of a temporary grant; a consortium for outstanding achievement in teaching with technology; changes implemented after technology professional development sessions; Web-based modules for teaching mathematics to minority students; student teaching technology sites; preservice teachers design technology-enhanced learning experiences; planning, implementing, evaluating, and reflecting on ...

2002-03-01

347

Study on reactivity measurement by the Feynman-#alpha# method  

International Nuclear Information System (INIS)

The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).

1996-09-01

348

Si(111)/Gd: A fast and high-resolution thermal neutron detector  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.

1998-07-01

349

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

350

Research in experimental elementary particle physics. A proposal to the U.S. Department of Energy  

Energy Technology Data Exchange (ETDEWEB)

We report on the activities of the High Energy Physics Group at the University of Texas at Arlington for the period 1994-95. We propose the continuation of the research program for 1996-98 with strong participation in the detector upgrade and physics analysis work for the D0 Experiment at Fermilab, prototyping and pre-production studies for the muon and calorimeter systems for the ATLAS Experiment at CERN, and detector development and simulation studies for the PP2PP Experiment at Brookhaven.

1995-04-13

351

Radon concentration measurements in the soil  

International Nuclear Information System (INIS)

Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)

352

Proposed high-resolution vertex detector using superconductive thin strips  

Energy Technology Data Exchange (ETDEWEB)

The possibility of fabricating a superconductive vertex detector is discussed on the basis of a preliminary experiment. The experiment has shown that an indium strip 15 mm long, 20 ..mu..m wide and 0.1 ..mu..m thick is changed from the superconductive state to the normal state when struck by a single 5.4 MeV alpha particle.

1984-06-01

353

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

354

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

355

Performance of the transition radiation detector in D{Phi}  

Energy Technology Data Exchange (ETDEWEB)

The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.

1994-12-31

356

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

357

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

358

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

359

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

360

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

361

Medical explorations by radioisotopes in Lebanon  

International Nuclear Information System (INIS)

This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.

362

Interaction region layout of the VLEPP based photon linear collider with ultimate luminosity  

Energy Technology Data Exchange (ETDEWEB)

In the present paper, a possible interaction region layout of the VLEPP based Photon Linear Collider (PLC) with ultimate luminosity is discussed. In order to remove spent electron beams, the crab-crossing scheme is used. The detector is protected from produced pairs and secondary particles by means of the detector magnetic field and a shielding mask. ((orig.)).

1995-02-01

363

Gamma ray detecting device using dislocation-free crystal  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.

1991-04-30

364

GaAs detector optimization for different medical imaging applications  

International Nuclear Information System (INIS)

We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)

1999-09-11

365

First tests of "bulk" MICROMEGAS with resistive cathode mesh  

CERN Document Server

We present the first results from tests of a MICROMEGAS detector manufactured using the so-called "bulk" technology and having a resistive cathode mesh instead of the conventional metallic one. This detector operates as usual MICROMEGAS, but in the case of sparks, which may appear at high gas gains, the resistive mesh reduces their current and makes the sparks harmless. This approach could be complementary to the ongoing efforts of various groups to develop spark-protected MICROMEGAS with resistive anode planes.

2010-01-01

366

Explosives detection: the problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.

1984-01-01

367

Direct gamma-spectrometry of surface activity with IGC-30 HPGe detector  

International Nuclear Information System (INIS)

The IGC-30 HPGe detector with MCA 'CANBERRA-10 PLUS' allows to determine surface contamination of areas of any type with a minimum error in radius 8-10 m, at a 'uniform' contamination. A modification of the CANBERRA hardware and software is described allowing determination of both the activity of a possible 'radioactive spot' and the activity of the whole observed surface. (author).

1993-12-02

368

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

369

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

370

Determination of reactor kinetic parameters in a two-core reactor  

Energy Technology Data Exchange (ETDEWEB)

The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.

1982-01-01

371

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

372

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

373

Detection device for high explosives  

Energy Technology Data Exchange (ETDEWEB)

A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

1992-01-01

374

Ceramic inspection system  

Science.gov (United States)

A system for inspecting a ceramic component. The ceramic component is positioned on a first rotary table. The first rotary table rotates the ceramic component. Light is directed toward the first rotary table and the rotating ceramic component. A detector is located on a second rotary table. The second rotary table is operably connected to the first rotary table and the rotating ceramic component. The second rotary table is used to move the detector at an angle to the first rotary table and the rotating ceramic component.

2006-05-16

375

CPA simulator: A software tool to simulate nuclear front-end circuit response  

International Nuclear Information System (INIS)

A computer program 'CPA simulator' has been designed to simulate the response parameters of a typical charge preamplifier (CPA) used in nuclear front-end electronics. The response parameters are studied considering three common connection methods between the detector and the CPA. The simulator predicts and illustrates the role and influence of the different components of the CPA and detector circuits.

2010-12-21

376

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and ...

1984-06-05

377

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

378

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side ...

2005-11-23

379

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

380

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation ...

1995-11-01

381

A solution for solid state detector and preamplifier protection, during HV application and removal transition periods  

International Nuclear Information System (INIS)

Surface barrier detectors may be damaged, because of microplasma breakdown, in rapid application of bias voltage. The high performance FETs of very low noise preamplifiers may also be damaged by rapid changes of the bias voltage. The electronic device described permits the gradual application and removal of the bias voltage, without any influence on the power supply specification. (Auth.).

382

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

383

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

384

Recent Progress in CdTe and CdZnTe Detectors  

CERN Document Server

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these ...

2001-01-01

385

GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy  

Energy Technology Data Exchange (ETDEWEB)

High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended ...

2004-12-21

386

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an ...

2002-01-01

387

Design and implementation of the BESIII detector-control system  

Energy Technology Data Exchange (ETDEWEB)

In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has ...

2008-07-21

388

On the indentation failure of carbon-epoxy cross-ply laminates, and its suppression by elasto-plastic interleaves  

Energy Technology Data Exchange (ETDEWEB)

Elastic and elasto-plastic modelling of indentation in CFRP cross-ply laminates has been performed. Detailed knowledge of the field solutions in the volume below the indentor forms the basis for the reported micromechanical interpretation of the observed damage in test specimens. The analysis shows that matrix cracks originate at sites of maximum tensile stress perpendicular to fibers. The predicted stress fields due to indentation show that stress concentrations occur in the interface between alternating plies. It is found that microcracking in this zone is a precursor to the observed failure. This analysis is supported by in-situ scanning electron microscopy during loading by a cylindrical indentor onto the laminate supported on a rigid substrate. The microscopy reveals microdamage in the region of interfacial tensile stress concentrations. The onset of indentation failure in these layered composites suggests that plastic interleaves would ...

1997-08-01

389

The effect of the changing microstructure on the fatigue behaviour during cyclic rolling contact loading  

Energy Technology Data Exchange (ETDEWEB)

During rolling contact fatigue of the inner rings of ball bearings three stages of material response can be distinguished, in terms of the volume that is plastically deformed upon overrolling. After a first stage of material strengthening during which a decrease occurs for the volume that is deformed plastically, an effectively stationary, second stage is entered which is eventually succeeded by a third stage exhibiting a pronounced increase of the volume that is deformed plastically upon overrolling, which leads to failure. It is suggested that carbon diffusion induced by local temperature peaks occurring at the moment of overrolling is the key mechanism leading to fatigue damage. The amount of decomposed retained austenite is a useful, practical parameter to assess fatigue life. It is shown that published ideas about the role of certain components of residual stress in enhancing fatigue life are not correct and that the ...

1997-04-01

390

Micro-hardness measurements to evaluate composition gradients in metal-based functionally graded materials  

Energy Technology Data Exchange (ETDEWEB)

Micro-Vickers hardness measurement has been used to determine the composition of functionally graded materials (FGMs). Materials used in the present study are Al-SiC, Al-Shirasu and Al-Al{sub 3}Ni FGMs, which are fabricated by a centrifugal method. The micro-hardness of the aluminum matrix for Al-SiC FGM markedly increases as the volume fraction of SiC particles increases. However, the tendency is not so clear in the cases of Al-Shirasu and Al-Al{sub 3}Ni FGMs. Plastic strain energy due to thermal misfits between the matrix and dipersed particles is calculated based on an elasto-plastic analysis by applying a shell theory after Lee et al. The hardness is correlated theoretically with the composition gradient through the mean plastic strain energy (responsible for dislocation density). It is concluded that the composition gradient of metal-based FGMs can be determined from micro-hardness measurements. (orig.)

2001-01-01

391

High-strength fiber-reinforced plastic reinforcement of wood and wood composite  

Energy Technology Data Exchange (ETDEWEB)

Research and development underway since 1982 has led to the development of a method of reinforcing wood and wood composite structural products (WWC) using high-strength fiber-reinforced plastic. This method allows the use of less wood fiber and lower grade wood fiber for a given load capacity. The first WWC in which reinforcement has been marketed is glulam beams. Marketed under the trade name FiRP{trademark} Reinforced glulam, the product has gained code approval and is now being used in the construction of buildings and bridges in the United States, Japan and other countries. The high-strength fiber-reinforced plastic (FiRP{trademark} Reinforced panel (RP)) has specific characteristics that are required to provide for proper use in WWC`s. This paper discusses these characteristics and the testing requirements to develop code approved allowable design values for carbon, aramid and fiberglass RP`s for such uses. Specific issues such as ...

1996-12-31

392

Flock-like painting for interior plastic parts. Naisoyo shokumocho toso no kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

Lower cost painting flock-like in appearance and touch feeling was developed as a new surface softening method for automobile interior plastic molded parts. The base coat with the same color as piles mixed into a top coat was first painted on the surface of a plastic molded part after cleaning, and after the top coat with less pitch mixed with piles was painted on the wet base coat and dried by a heater, excess piles were removed with suction and air blowing to produce flock-like appearance. Nylon 66 of 0.4mm in length was used as piles, and mixed into the top coat by 8.0wt% in content. This painting method was applicable to even such parts as one with a complex configuration, and one impossible to set piles on it by conventional methods because of poor durability. As a certain amount of piles with different colors were mixed into the top coat, sprinkly colored appearance, unattainable by conventional methods, could be also produced. 1 ref., 13 ...

1990-04-25

393

Field-controllable electro- and magneto-rheological fluid dampers in flow mode using Herschel-Bulkley theory  

Science.gov (United States)

The Bingham plastic constitutive model has been widely used to predict the post-yield behavior of electro- and magneto- rheological fluids (ER and MR fluids). However, if these fluids experience shear thinning or shear thickening, the Bingham plastic model may not be an accurate predictor of behavior, since the post-yield plastic viscosity is assumed to be constant. In a recent study, it was theoretically and experimentally demonstrated that the Herschel-Bulkley fluid model can be successfully employed when evaluating non- Newtonian post-yield behavior of ER and MR fluids. In this paper, the Herschel-Bulkley model is employed to include a detailed analysis of ER and MR fluid dynamics through pipes and parallel plates. Simplified explicit expressions for the exact formulation are also developed. It is shown that the proposed simplified model of the Herschel-Bulkley steady flow equations for pipes and parallel plates can be ...

2000-04-01

394

Elasto-plastic analysis of settlement of pile foundations. Part 2. ; Prediction of immediate settlement of building. Kui kiso no dansosei chinka kaiseki. 2. ; Kenchikubutsu no sokuji chinka yosoku hoho  

Energy Technology Data Exchange (ETDEWEB)

When the foundations of the building are designed and worked, the prediction calculation of immediate settlement of the building exercised practically is to calculate assuming the earth is a linear elastic body, but the actual stress-strain relationship of the earth is nonlinear and rigidity of the earth becomes lower as strain (or stress) increases. Hence in order to grasp the actual settling behavior of the earth, it is necessary to elucidate the nonlinear relationship between stress and strain. In this article, a prediction method of building settlement is introduced which uses an analytical technique of the multi-layered earth by the linear elasticity theory and takes into consideration strain dependency of rigidity of the earth. Part of the conclusion is as follows which has been obtained by studying the settling behaviors observed in examples of vertical loading tests of the pile foundations and the elasto-plastic settlement analytical method of the pile ...

1992-12-25

395

Dislocation accumulation at large plastic strains -- An approach to the theoretical strength of materials  

Energy Technology Data Exchange (ETDEWEB)

The usual method of introducing engineers to the concept of dislocations and their role in plastic flow is to compare an estimate of the theoretical strength of solid (of order {micro}/30 where {micro} is the shear modulus) and the observed strength of either single crystals ({mu}/10{sup 4}) or practical engineering material such as structural steels where the yield stress in shear is of order {mu}/10{sup 3}. However, if one considers the problem in reverse, one can consider the accumulation of dislocations as an important mechanism by which one can produce engineering materials in which the strength level approaches the theoretical strength. If one assumes that the flow stress can be expressed in terms of te mean free path between stored dislocations or as the square root of the global dislocation density, then one can see the influence of dislocation density in a diagrammatic form. It is clear that the strengthening by dislocation accumulation due to large ...

1999-04-01

396

Comparative experimental study of dual energy subtraction and conventional digital radiography on chest  

International Nuclear Information System (INIS)

Objective: To compare the efficiency of dual energy subtraction and conventional direct digital radiography in signal detecting ability. Methods: 200 plastic balls which were 4 mm in diameter were taken as signals and were placed on a 10 cm thick plastic board and the right upper thorax of a healthy volunteer. The signals were examined by DES and CDR separately and were estimated by 3 radiologists with 5-value-differentiation method. ROC curve analysis was made by ROC kit software. Results: when signals on plastic board were detected by CDR and DES, ROC curve analysis indicated that there was no significant difference (P=0.4851 > 0.05, two-tailed) between the area under the ROC curves of the two methods (Az=0.9931 for CDR and Az=0.9879 for DES). The difference was significant (P=0.0002 <0.01, two-tailed) between the area under the ROC curves of CDR and DES (Az=0.7276 for CDR and Az=0.8561 for DES), when the signals on ...

2005-06-01

397

Amount of confining reinforcement required for flexural ductility of reinforced concrete columns. Tekkin concrete chu buzai no mage jinsei to yokokosoku (confined) hokyo kinryo  

Energy Technology Data Exchange (ETDEWEB)

In this paper, an amount of confining reinforcement required for the sufficient flexural ductility of reinforced concrete column was investigated. An equation to calculate the required confining reinforcement ratio was deduced from the analytical investigation and examination on the previous experimental data as to the effects of various factors on the required confining reinforcement ratio. The rotation angle required in plastic hinges, the axial force ratio, the material properties such as concrete strength, and the ratio of core area to the whole area of column sections were employed as the factors. From the examination of the equation, it was shown that the ultimate rotation in plastic hinges calculated by the equation was more conservative than the ultimate rotaion angle of members obtained by test column specimens. It was also indicated that the ultimate rotation angle of members of columns failed in shear was smaller than the ultimate ...

1991-09-15

398

Effects of plastic waste injection on the cupola furnace and blast furnace process; Auswirkungen des Einblasens von Kunststoffabfaellen auf den Kupolofen- und Hochofenprozess  

Energy Technology Data Exchange (ETDEWEB)

On account of a raised appearing of plastic waste and shreddered light fraction (SLF) from old car utilization as well as legal handicaps experiments were carried out at the Institute of Ferrous Metallurgy (RWTH Aachen) on a laboratory rig to inject DSD (Duales System Deutschland)-plastic waste and SLF with the destination of a subsequent raw material utilization in the blast furnace and cupola furnace. The experiments on the laboratory rig with DSD plastics could verify that by injection of specific coal/plastic mixtures into the blast furnace the injection rate could be raised by an improvement in the conversion degree and therefore the amount of the inserted reducing agent can be lowered. The injection of SLF without reduction of the inert materials and of the contents on alloying elements and/or tramp elements by extensive preparation has no advantages according to the experiments for the blast ...

1996-01-01

399

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for ...

1997-05-01

400

Thermal and mechanical properties of poly(vinyl alcohol) plasticized with glycerol  

British Library Electronic Table of Contents (United Kingdom)

Abstract Thermomechanical behavior of membranes based on blends of poly(vinyl alcohol) (PVA) with different weight percentage (wt %) of glycerol has been studied. Solid-state PVA/Glycerol polymer membranes were prepared by a solution casting method. The films were studied for thermal characteristics by differential scanning calorimetry (DSC) and thermogravimetric analysis and for the mechanical properties including hardness and modulus by nanoindentation method. The dispersion of glycerol within the polymer matrix was examined using scanning electron microscopy. Fourier transform infrared spectroscopy was used to confirm the formation of hydrogen bonding between the plasticizer and PVA in their blends and also to provide information on compatibility and physical interactions between the gl...

2011-01-01

401

Surface characteristics and overlaying properties of flat-pressed wood plastic composites  

British Library Electronic Table of Contents (United Kingdom)

This study evaluated surface characteristics and overlaying properties of wood plastic composite (WPC) panels made from dry-blended rubber wood fiber-polypropylene (PP) powder formulations using a conventional flat-press process under laboratory conditions. Three levels of rubberwood fibers (Hevea brasiliensis), 40%, 50%, and 60%, based on the composition by weight, were mixed with the PP powder without and with 3% (based on weight) maleic anhydride grafted PP (MAPP) as a coupling agent. Contact angle measurements on the WPC samples were performed using a goniometer connected with a digital camera which collected one image per second. Roughness measurements, average roughness (R a), mean peak-to-valley height (R z), and maximum roughness (R y), were taken from the sanded samples along and ...

2011-01-01

402

Stress measurements in welds: Problem areas  

Energy Technology Data Exchange (ETDEWEB)

There have been many stress measurements on welds by neutron diffraction over the past 20 years but there are still a number of serious experimental issues that are often not addressed. The primary fact is that the microstructure generally changes across the weld and accompanying this may be a change in the concentration of strengthening elements in solution. This will lead to a shift in lattice spacing which may be incorrectly interpreted as a strain. Secondly, a gradient of plastic deformation near the weld may be expected. Since plastic deformation by application of a stress always generates intergranular (type-2) strains this may lead to a range of intergranular effects superposed on the conventional weld-related strains. The effects are illustrated by neutron diffraction studies of Zr-4, ferritic and austenitic welds where chemistry, intergranular effects and crystallographic texture can all play a role.

2006-11-10

403

Stability studies on refined soybean oil stored in various conditions  

International Nuclear Information System (INIS)

The 12 months stability study of freshly produced refined soybean oil revealed that refined soybean oil stored in plastic containers in dark was more hydrolytically and oxidatively stable than that stored in other containers in light condition. There was no significant difference at P < 0.05 in free fatty acids and acid value of oil stored under light and dark conditions in tin and glass containers but there was significant difference at P < 0.05 in peroxide value of oil stored in light and dark conditions in all the storage containers. Light increased the degree of oxidative rancidity of refined soybean oil, the most in tin containers, followed by glass containers and the least in plastic containers. (author)

2008-01-01

404

Short-term synaptic plasticity in the auditory brain stem by using in-vivo-like stimulation parameters  

British Library Electronic Table of Contents (United Kingdom)

Reduced systems such as brain slices offer a powerful approach to study the physiology of auditory neurons in great detail. However, when studying auditory nuclei in reduced systems such as brain slices, especially highly active auditory brain stem nuclei, one has to be aware that the unphysiological lack of activity in the reduced system compared to the in-vivo situation has a number of important effects on the neurons under investigation, and thus on the data that are measured. Most importantly, the lack of chronic activity in the slice preparation has important effects on the properties of short-term plasticity of the synapses. The main purpose of this article is to discuss how spontaneous activity in auditory neurons, or the lack thereof, can affect the data measured.

2011-01-01

405

Seasonal and clonal variations in technological and thermal properties of raw Hevea natural rubber  

British Library Electronic Table of Contents (United Kingdom)

Abstract This study was undertaken over a 10-month period under environmental conditions within the state of Mato Grosso, Brazil, to evaluate the causes of variation in the technological and thermal properties of raw natural rubber (NR) from different clones of Hevea brasiliensis (GT 1, PR 255, FX 3864, and RRIM 600). These clones were chosen to represent good clones available in Brazil. The technological properties of raw NR were evaluated in terms of their dry rubber content (DRC), Wallace plasticity, plasticity retention index (PRI), and Mooney viscosity. The thermal performance was evaluated with the thermogravimetry (TG)/differential thermogravimetry (DTG) technique. There were significant variations (p < 0.01 and p < 0.05) between clones and tappings for all technological properties,...

2011-01-01

406

Role of additives on tensile strength of wood-plastic composite  

International Nuclear Information System (INIS)

Wood-plastic composite (WPC) formation has been studied with simul + styrene system at various compositions of styrene with methanol as the swelling solvent. Effect of additives, e.g. multifunctional monomers (MFM)and oligomers used in very low quantity (1% v/v) on the polymer loading (PL) and tensile strength (TS) of the WPC has been elaborately investigated. Enhanced PL and TS values are observed. Inorganic co-additives like Lithium (Li"+), Copper (Cu"2"+) and acid (H"+) and urea (U) used in combinations with additives (MFM or oligomers) have influenced the results of PL and TS in these systems. Li"+ ion has been a good replacement for H"+ ion; U has substantially enhanced the PL values with retention of the TS values of WPC. Co-additive Cu"2"+ used in these systems can act as a preservative and protective agent for WPC. (Author).

1992-01-01

407

Role of additives in wood plastic composite of water soluble monomer  

International Nuclear Information System (INIS)

Wood plastic composites are prepared under radiation of "6"0Co gamma source with simul, a low grade wood of Bangladesh using a water soluble monomer acrylamide (AM) mixed with a swelling solvent methanol, water or methanol/water (1:1) at different compositions in the presence of a number of additives and co-additives such as NVP (N-vinylpyrrolidone), TPGDA (tripropylene glycol diacrylate), TMPTA (trimethylol propane triacrylate), sulfuric acid, urea and copper sulfate. Polymer loading (PL) and tensile strength (TS) of the composites are measured. The role of these additives on the composites is also discussed. It is observed that nitrogen-atom containing-materials like urea, NVP and AM produce composites with the highest mechanical strength, and incorporation of copper into this system provides additional property of protection and preservation of the composites against attacks by insects and microbes. (author).

1994-01-01

408

Reducing energy costs of plastics processing  

Energy Technology Data Exchange (ETDEWEB)

Ways of reducing energy consumption in plastics processing are examined. Examples are given which illustrate how the awareness of everyone in the company to energy saving is essential with particular reference to switching arrangements to ensure such things as lights, machinery, compressed air systems are switched off when not needed or run at a lower level where appropriate. An understanding of the various elements of the electricity bill can inform a company`s planning of its operations to take advantage of lower tariffs. Machinery selection both with regard to efficiency of processing, quality of engineering and appropriate size can achieve significant savings and attention to maintenance is important. Fundamental to all aspects of energy saving is the monitoring of energy usage to identify where savings can be made and to evaluate the effectiveness of any measures taken. (UK)

1995-02-01

409

Properties of wood-plastic composites: effect of inorganic additives  

International Nuclear Information System (INIS)

Wood-plastic composites from Syrian tree species (white poplar, cypress tree, and white willow) were prepared using gamma-ray irradiation. Dry wood was impregnated with acrylamide or butylmethacrylate at various methanol compositions as the swelling solvent. Effect of inorganic additives and co-additives such as lithium nitrate (LiNO_3), copper sulfate (CuSO_4) and sulfuric acid (H_2SO_4), used at a very low concentration (1%), on the polymer loading (PL) and the compression strength (CS) was also investigated. It has been found that all the additives and co-additives, except Cu"2"+, increase the PL values and only Li"+ has a positive effect on CS. (Author)

2003-01-01

410

Phenotypic plasticity in sex allocation for a simultaneously hermaphroditic coral reef fish  

British Library Electronic Table of Contents (United Kingdom)

Phenotypic plasticity can facilitate reproductive strategies that maximize mating success in variable environments and lead to differences in sex allocation among populations. For simultaneous hermaphrodites with sperm competition, including Serranus tortugarum a small coral reef fish, proportional male allocation (testis in total gonad) is often greater where local density or mating group size is higher. We tested whether S. tortugarum reduced male allocation when transplanted from a higher density site to a lower density site. After 4?months, transplants mirrored the sex-allocation patterns of the resident population on their new reef. Transplants had significantly lower male allocation than representatives from their source population, largely as a result of reduced testis mass relative...

2011-01-01

411

New Radiation Stable and Long-Lived Plastic Scintillators  

International Nuclear Information System (INIS)

A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiation hardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiation hardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is shown that one of the main reasons for aging of plastic scintillators is residual monomer. 10 refs., 18 figs., 1 tab.

1993-11-15

412

Multimodal MRI assessment of damage and plasticity caused by status epilepticus in the rat brain  

British Library Electronic Table of Contents (United Kingdom)

Summary Status epilepticus or other brain-damaging insults launch a cascade of events that may lead to the development of epilepsy. MRI techniques available today, including T2- and T1-weighted imaging, functional MRI, manganese enhanced MRI (MEMRI), arterial spin labeling (ASL), diffusion tensor imaging (DTI), and phase imaging, can detect not only damage caused by status epilepticus but also plastic changes in the brain that occur in response to damage. Optimal balance between damage and recovery processes is a key for planning possible treatments, and noninvasive imaging has the potential to greatly facilitate this process and to make personalized treatment plans possible.

2011-01-01

413

Morphotypes of Varroa destructor collected in Apis mellifera colonies from different geographic locations of Argentina  

British Library Electronic Table of Contents (United Kingdom)

Parasites display considerable phenotypic plasticity in life-history traits such as, body size. Varroa destructor is an ectoparasitic mite of the western honey bee Apis mellifera. Several studies have reported that in V. destructor, there is a wide phenotypic plasticity within a population of mites. However, it is unknown if there are morphologic variations in V. destructor populations affecting different A. mellifera populations. A morphometric study of V. destructor populations was conducted to provide information concerned to the relationships among parasite populations found in different geographic locations from A. mellifera colonies of Argentina. The hypothesis tested was different morphotypes of V. destructor populations parasitizing different A. mellifera populations from Argentina...

2009-01-01

414

Modeling of Anisotropic Inelastic Behavior  

Energy Technology Data Exchange (ETDEWEB)

An experimental capability, developed at Lawrence Livermore National Laboratory (LLNL), is being used to study the yield behavior of elastic-plastic materials. The objective of our research is to develop better constitutive equations for polycrystalline metals. We are experimentally determining the multidimensional yield surface of the material, both in its initial state and as it evolves during large inelastic deformations. These experiments provide a more complete picture of material behavior than can be obtained from traditional uniaxial tests. Experimental results show that actual material response can differ significantly from that predicted by simple idealized models. These results are being used to develop improved constitutive models of anisotropic plasticity for use in continuum computer codes.

2000-02-25

415

Modeling and optimization of a propeller-type tribocharger for granular materials  

British Library Electronic Table of Contents (United Kingdom)

Electrostatic separation has already proved to be an effective means for the recycling of granular plastics from industrial wastes. The aim of the present work was to optimize the operation of a novel device that could ensure effective triboelectric charging of such materials prior to their selective sorting in a high-intensity electric field. The experiments were performed on two sorts of mm-size granular materials Acrylonitrile Butadiene Styrene and High Impact Polystyrene, originating from the processing of waste electric and electronic equipment. The samples were introduced in a Polyvinyl Chloride cylinder, where a co-axial propeller entrained the plastic granules into a helical motion that favored their triboelectric charging by combining the mechanical and aerodynamical effects. The ...

2011-01-01

416

Microstructures and mechanical properties of pure copper deformed severely by equal-channel angular pressing and high pressure torsion  

International Nuclear Information System (INIS)

Pure Cu of 99.98 wt.% purity has been processed at room temperature by diverse techniques of severe plastic deformation, namely equal-channel angular pressing (ECAP), high pressure torsion (HPT) and a combination of both in order to find out the evolution on the microstructural homogeneity for each of the processes and their combination. Starting with a grain size of #approx#60 #mu#m, severe plastic deformation has been introduced to the material while maintaining the sample dimensions unchanged through the processes of ECAP and HPT. A significant decrease in grain size was observed by transmission electronic microscopy (TEM). Microtensile and microhardness tests were carried out on the deformed material in the three processing conditions. A significant improvement of the tensile strength was promoted with admissible penalization on ductility.

2008-03-25

417

Materials and processing designs for high-performance magnesium alloys  

Energy Technology Data Exchange (ETDEWEB)

Materials and processing designs for advanced magnesium alloys with fine microstructures and superior properties were established by the combination of the repeated plastic working and the Mg{sub 2}Si synthesis in solid-state. The grain size was less than 1 {mu}m via RPW process due to its severe plastic working on raw powder. The hot extruded magnesium alloys produced in industries showed high ultimate tensile strength, e.g. 420{proportional_to}450 MPa, when employing Mg-Zn-Al-Ca-RE (Rare Earth) alloy coarse powder, having 0.5{proportional_to}2 mm diameter, as input materials. (orig.)

2005-07-01

418

Laser-assisted asymmetric incremental sheet forming of titanium sheet metal parts  

British Library Electronic Table of Contents (United Kingdom)

Asymmetric Incremental Sheet Forming (AISF) is a relatively new manufacturing process. In AISF, a CNC driven forming tool imposes a localized plastic deformation as it moves along the contour of the desired part. Thus, the final shape is obtained by a sequence of localized plastic deformations. AISF is suitable for small series production of sheet metal parts as needed in aeronautical and medical applications. Two main process limits restrict the range of application of AISF in these fields. These are the low geometrical accuracy of parts made from titanium alloys or high strength steels and, for titanium alloys, the limited formability at room temperature. In this paper a new concept for laser-assisted AISF is introduced including the required components. Furthermore, the CAX tools used f...

2011-01-01

419

Internal strain and texture evolution during deformation twinning in magnesium  

Energy Technology Data Exchange (ETDEWEB)

The development of a twinned microstructure in hexagonal close-packed rolled magnesium compressed in the in-plane direction has been monitored in situ with neutron diffraction. The continuous conversion of the parent to daughter microstructure is tracked through the variation of diffraction peak intensities corresponding to each. Approximately 80% of the parent microstructure twins by 8% compression. Elastic lattice strain measurements indicate that the stress in the newly formed twins (daughters) is relaxed relative to the stress field in the surrounding matrix. However, since the daughters are in a plastically 'hard' deformation orientation, they quickly accumulate elastic strain as surrounding grains deform plastically. Polycrystal modeling of the deformation process provides insight about the crystallographic deformation mechanism involved.

2005-06-15

420

Impact of Hight Velocity Cold Spray Particles  

Energy Technology Data Exchange (ETDEWEB)

This paper presents experimental data and an computational model of the cold spray solid particle impact process. Copper particles impacting onto a polished stainless steel substrate are examined. The high velocity impact causes significant plastic deformation of both the particle and the sub- strate, but no melting is observed. The plastic deformation exposes clean surfaces that, under the high impact pressures, result in significant bond strengths between the particle and substrate. Experimental measurements of the splat and crater sizes compare well with the numerical calculations. It is shown that the crater depth is significant and increases with impact velocity. However, the splat diameter is much less sensitive to the impact velocity. It is also shown that the geometric lengths of the splat and crater scale linearly with the diameter of the impacting particle. It is hoped that the results presented will allow better understanding of the ...

1998-12-01

421

Hydrogen effect on cold rolling texture of stable #beta#-titanium alloy  

International Nuclear Information System (INIS)

A study was made into microstructure and texture of cold rolled titanium alloy VT-35 with various hydrogen content aimed to reveal hydrogen influence on the mechanism of cold plastic deformation by rolling. Experiments were carried out using sheets 1.2 mm thick hydrogenated up to hydrogen concentrations from 0.06 to 0.554 mass. %. All specimens constituted a single-phase FCC #beta#-solid solution. It is shown that small hydrogen additions have a plasticizing effect on #beta#-titanium alloys in their cold rolling. The character of texture is dependent on hydrogen concentration and determined by deformation mechanism. 6 refs.; 5 figs.

422

Grain size effects on the tensile properties and deformation mechanisms of a magnesium alloy, AZ31B, sheet  

International Nuclear Information System (INIS)

The grain size dependence of the tensile properties and the deformation mechanisms responsible for those properties are examined for Mg alloy, AZ31B, sheet. Specifically, the Hall-Petch effect and strain anisotropy (r-value) are characterized experimentally, and interpreted using polycrystal plasticity modeling. {1 0 . 2} extension twins, {1 0 . 1} contraction twins, and so-called 'double-twins' are observed via microscopy and diffraction-based techniques, and the amount of twinning is found to increase with increasing grain size. For the sheet texture and tensile loading condition examined, {1 0 . 2} extension twinning is not expected, yet the polycrystal plasticity model predicts the observed behavior, including this 'anomalous' tensile twinning. The analysis shows that the Hall-Petch strength dependence, of the polycrystal as a whole, is primarily determined by the grain size dependence of the strength of the prismatic slip systems.

2008-07-15

423

Gas chromatography - mass-spectrometry of volatiles released from plastics used as building materials  

Energy Technology Data Exchange (ETDEWEB)

The possibility of employing a number of adsorbents (polyphenylquinoxaline, Tenax GC, Carbopak C, graphitized thermal carbon black, silica gels modified with pyrocarbon or hexamethyldisilazane) for the trapping of organic traces from air has been investigated. Adsorption capacities of these adsorbents with respect to a number of volatiles released from certain plastics used as building material (polyvinylchloride, Relin, Acronal, etc.) have been measured. A number of the volatiles were identified by gas chromatography - mass-spectrometry after trapping on the adsorbents investigated. Chromatographic separation after trapping on the adsorbents was carried out on wall-coated open-tubular capillary columns as well as in capillary columns packed with graphitized thermal carbon black.

1983-10-01

424

Evolution of lattice strain in Ti-6Al-4V during tensile loading at room temperature  

International Nuclear Information System (INIS)

The evolution of intergranular lattice strains in a textured, forged bar (Bar) sample of the #alpha# - #beta# titanium alloy Ti-6Al-4V has been characterised using in situ X-ray diffraction. A two-phase elastic-plastic self-consistent (EPSC) model has been developed to rationalise the results. Of the orientations analysed, it is found that the #left brace#2 0 0#right brace# #beta# orientation is the most compliant and that load partitions to this orientation during plasticity. The results from the bar material have then been used to predict the response of unidirectionally rolled plate (UD) Ti-6Al-4V. It is predicted that the residual lattice strains in the #left brace#101-bar0#right brace# and #left brace#112-bar0#right brace# orientations will be significantly higher in the UD material.

2008-12-01

425

Electrical properties and x-ray diffraction of wood and wood plastic composite (WPC)  

Energy Technology Data Exchange (ETDEWEB)

Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).

1991-01-01

426

Effect of thermal-treatment of wood fibres on properties of flat-pressed wood plastic composites  

British Library Electronic Table of Contents (United Kingdom)

This study aimed to enhance the dimensional stability of flat-pressed wood plastic composites (WPCs) containing fast growing wood fibres by a thermal-treatment method. The wood fibres were treated at three different temperatures (120, 150, or 180 degreeC) for 20 or 40 min in a laboratory autoclave. The WPC panels were made from dry-blended Eucalyptus camaldulensis wood fibres and polypropylene (PP) powder (50:50 by weight) using a conventional flat-press process under laboratory conditions. Thickness swelling and water absorption of the WPC panels significantly decreased with increasing the treatment temperature and time. The thermal-treatment of eucalyptus wood fibres slightly decreased the screw withdrawal resistance of the WPC panels as compared to the reference panels while the flexura...

2011-01-01

427

Comparison of constitutive models for plastic-bonded explosives  

British Library Electronic Table of Contents (United Kingdom)

A constitutive model for an explosive consists of three parts: equation of state of reactants, equation of state of products, and reaction rate. In the absence of a good physical theory, models are empirical and based on heuristics. For the HMX based plastic-bonded explosive PBX 9501, three models have previously been calibrated and used in numerical simulations. Here, these three models are compared. They illustrate several generic difficulties with developing and validating models. The available data is insufficient to determine a constitutive model uniquely. Different models can be calibrated to fit the available data yet differ significantly in regions of phase space of importance to applications. Comparing models gives an indication of the uncertainty in model predictions outside the ...

2008-01-01

428

Comparative study on the technological properties of latex and natural rubber from Hancornia speciosa Gomes and Hevea brasiliensis  

British Library Electronic Table of Contents (United Kingdom)

This work reports a systematic comparative study of the technological properties of natural lattices and rubbers extracted from Hancornia speciosa Gomes and Hevea brasiliensis [(Willd. ex Adr. de Juss.) Muell.-Arg.] (clone RRIM 600) trees from 11 collections in Brazil throughout 2004. Natural rubber latex particle sizes and distributions were quite similar with an average diameter around 1 mm. Molecular weight, Wallace plasticity, and Mooney viscosity values were approximately the same for both rubbers. Fourier transform infrared spectroscopy peaks characteristic of natural rubber were observed for both Hancornia and Hevea. The measured differences in technological properties included lower values for Hancornia dry rubber content, % ash, % nitrogen, and plasticity retention index but highe...

2009-01-01

429

Comparative study of maleated polypropylene as a coupling agent for recycled low-density polyethylene/wood flour composites  

British Library Electronic Table of Contents (United Kingdom)

Abstract The effects of the type of coupling agent and virgin polypropylene (PP) content on the mechanical properties and water absorption behavior of recycled low-density polyethylene/wood flour (WF) composites were investigated. The fractured surfaces of these recycled wood/plastic composites (rWPCs) were examined to gain insight into the distribution and dispersion of WF within the polymer matrix. The results indicate that the use of 100% recycled polymer led to inferior mechanical properties and to a greater degree of moisture absorption and swelling when compared to recycled polymer-virgin PP wood/plastic composites. This could have been related to the poor melt strength and inferior processability of the recycled polymer. The extent of improvement of the mechanical properties depende...

2011-01-01

430

Allylic monomers as reactive plasticizers of polyphenylene oxide. Part I: Uncured systems  

British Library Electronic Table of Contents (United Kingdom)

The effect of various diallyl (diallyl ortho phthalate, diallyl terephthalate and diethylene glycol diallyl carbonate) and triallyl monomers (triallyl cyanurate and triallyl isocyanurate) on the processability of polyphenylene oxide (PPO) was studied. The solubility parameters of the monomers indicated that diallyl orthophalate, dially terephthalate and triallyl cyanurate should be miscible with PPO suggesting their applicability as reactive plasticizers to improve the processability of PPO. Rheological studies of 60:40 wt:wt PPO:allylic blends indicate that the addition of 40wt% of allylic monomers significantly improved processability - blends of 60PPO:40DEGDAC indicates the highest viscosity and the highest T"g. Rheological studies and dynamic mechanical analysis on various PPO/DAOP ble...

2011-01-01

431

A simple model for explosives formulation  

Energy Technology Data Exchange (ETDEWEB)

A simple model based on surface chemistry is developed, based an simple concepts of contact angle, wetting and spreading. Results of the modeling can be stated by two simplified rules of thumb'': (1) A liquid will spread on the surface of a solid if the surface tension of the liquid is lose than the surface free energy of the solid, and (2) The liquid having the surface tension nearest that of the solid will preferentially wet the surface of the solid. These two rules can then be used to define the parameters that constitute a process for formulating a plastic bonded explosive (PBX), which is a crystalline high-explosive material coated with a small amount of plastic polymeric material (the binder). The PBX then can be pressed to a high density, and machined to a specific shape. The pressed and machined explosive material can then be used in a physics experiment to study fundamental properties of either the explosive or some ...

1993-01-01

432

A simple model for explosives formulation  

Energy Technology Data Exchange (ETDEWEB)

A simple model based on surface chemistry is developed, based an simple concepts of contact angle, wetting and spreading. Results of the modeling can be stated by two simplified ``rules of thumb``: (1) A liquid will spread on the surface of a solid if the surface tension of the liquid is lose than the surface free energy of the solid, and (2) The liquid having the surface tension nearest that of the solid will preferentially wet the surface of the solid. These two rules can then be used to define the parameters that constitute a process for formulating a plastic bonded explosive (PBX), which is a crystalline high-explosive material coated with a small amount of plastic polymeric material (the binder). The PBX then can be pressed to a high density, and machined to a specific shape. The pressed and machined explosive material can then be used in a physics experiment to study fundamental properties of either the explosive or some other material.

1993-04-01

433

Use of primary electron counting for detection of ultrasoft x-rays with a low-pressure multistep gaseous detector  

International Nuclear Information System (INIS)

The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.

434

Ultraviolet detectors based on ZnO films by thermal oxidation of Zn metallic films  

British Library Electronic Table of Contents (United Kingdom)

Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.

2008-01-01

435

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

436

Status of combined point source search with neutrino telescopes IceCube and AMANDA  

Energy Technology Data Exchange (ETDEWEB)

In this talk, we summarize recent results obtained from the combined neutrino telescopes IceCube and AMANDA. The combined approach, including data taken from both detectors simultaneously, is compared to other analyses that are using IceCube only data. The main benefit of the combined detector is its improved performance at low energies, meaning energies below 1 TeV (close to the energy threshold of the detector). The discussion is focused on the search for extra-terrestrial neutrinos from candidate sources in our Galaxy. Using appropriate cuts, the sensitivity can be optimized for soft spectra neutrino sources. With the resulting data sample, several studies are performed: an unbinned Galactic Plane Scan and a Cygnus region analysis: the Multi Point Source analysis. The current status of these analyses is presented.

2010-07-01

437

Spatial distribution of IGC-30 Ge-detector's efficiency  

International Nuclear Information System (INIS)

The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).

1993-12-02

438

Some considerations about future interferometric GW detectors  

International Nuclear Information System (INIS)

The two most important issues in designing future gravitational wave interferometric detectors are, in our opinion, thermal and optical noise. In this paper we discuss some approaches for reducing these noises. About thermal noise we show a possible cryogenic solution. About optical noise (namely, the combined effect of shot noise and radiation pressure noise) we show that it is possible to apply a recently proposed reduction strategy based on a 'quantum feedback' (Courty et al 2003 Phys. Rev. Lett. 90 083601; Courty et al 2003 Preprint gr-qc/0301068) to a full Fabry-Perot cavity. This can be seen as a further step towards the practical realization of a detector which is able to evade the standard quantum limit.

2004-03-07

439

Quartz fiber calorimetry and calorimeters  

CERN Document Server

Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward calorimeters.

2004-01-01

440

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

441

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

442

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.

443

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

444

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for ...

1995-12-31

445

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

446

Indoor and outdoor Radon concentration measurements in Sivas, Turkey, in comparison with geological setting  

British Library Electronic Table of Contents (United Kingdom)

Indoor and soil gas Radon (222Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor 222Rn gas concentration values. In the second stage, soil gas 222Rn measurements were performed using an alphameter near the selected h...

2010-01-01

447

High Energy Neutrino Telescopes  

CERN Document Server

This paper presents a review of the history, motivation and current status of high energy neutrino telescopes. Many years after these detectors were first conceived, the operation of kilometer-cubed scale detectors is finally on the horizon at both the South Pole and in the Mediterranean Sea. These new detectors will perhaps provide us the first view of high energy astrophysical objects with a new messenger particle and provide us with our first real glimpse of the distant universe at energies above those accessible by gamma-ray instruments. Some of the topics that can be addressed by these new instruments include the origin of cosmic rays, the nature of dark matter, and the mechanisms at work in high energy astrophysical objects such as gamma-ray bursts, active galactic nuclei, pulsar wind nebula and supernova remnants.

2008-01-01

448

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

449

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).

1983-08-26

450

Aging measurements of a TMAE-based photon detector for the HERA-B RICH  

CERN Document Server

We report on aging measurements of a photon detector candidate for the HERA-B RICH. The prototype, a proportional wire chamber operated with TMAE, was mounted on an argon filled test-beam RICH and was aged by UV light at rates we expect in HERA-B. We monitored gain and current continuously, and checked the chamber with Cherenkov photons at regular intervals. The number of detected photons/track (projected to 2.75 m C sub 4 F sub 1 sub 0 in HERA-B) dropped from 26 to 11 after two days of aging - well below the 20 required for pi/K separation. Based on these results, HERA-B decided to use multi-anode PMTs as photon detectors in the RICH.

1999-01-01

451

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

452

A planar circular detector based on multiple point chemi- or bio-luminescent source within a coaxial cylindrical reactor  

British Library Electronic Table of Contents (United Kingdom)

An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...

2009-01-01

453

Using Military Working Dog Teams (MWDTs) to Support Law ...  

Science.gov (United States)

... 4. Military Working Dogs iMWDs). As used in this Instruction refers to drug detector dogs only. 5. Military Working Doq Executive Agent M(WJDEMA. ...

1990-09-17

454

Use of solid state nuclear track detectors for radon concentration measurements indoors  

International Nuclear Information System (INIS)

An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.

455

The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy  

UK PubMed Central (United Kingdom)

BackgroundMany studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for...Full Text Available

456

The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the ...

2009-01-01

457

The Development of a Neutral Particle Detector for Observations of the Thermosphere  

Science.gov (United States)

One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight ...

2006-12-01

458

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

459

Search for free quarks at PEP  

Energy Technology Data Exchange (ETDEWEB)

The results of a search for fractionally charged particles produced in e/sup +/e/sup -/ annihilation at 29 GeV/c/sup 2/ are discussed. Results from cosmic-ray searches for fractionally charged particles, tachyons, and massive particles using the same detector are also presented.

1982-01-01

460

Research in heavy-ion nuclear physics  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.

1992-01-01

461

Radon concentration measurement in dwellings in Belgrade  

International Nuclear Information System (INIS)

The results of the radon concentration measurements in dwellings in Belgrade were shown in this paper. The measurements were done using long term method with diffusion cups equipped with solid state nuclear track detector LR-115-II or CR-39. (author).

462

Post-column reaction detector for platinum(II) antieoplastic agents  

Energy Technology Data Exchange (ETDEWEB)

The development and evaluation of a post-column reaction detector sensitive to platinum(II) complexes is presented in which sodium bisulfite is used as the derivatizing agent with potassium dichromate as an activating agent. The influences of mobile phase changes (i.e., pH, organic modifiers, electrolytes), oxygen, metal ions, and order of reagent addition on reaction kinetics and product yield are defined and used in optimization of detector response. Detection at lambda/sub max/ 290 nm results in an on-line post-column sensitivity of 40-60 ng/mL for selected cis-dichloroplatinum complexes and a sensitivity of 300-1200 ng/mL for four (substituted)-malonato-platinum complexes. The reaction detector is used to monitor the kinetics of aquation of cisplatin (CDDP) and to quantitate CDDP degradation in plasma. As the sensitivity for CDDP in plasma is comparable to that achieved from high pressure liquid chromatography (HPLC) ...

1984-03-01

463

Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies  

International Nuclear Information System (INIS)

A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 refs., 2 figs.

464

Photoconductive ultraviolet detectors based on ZnO films  

Energy Technology Data Exchange (ETDEWEB)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant {tau} obtained from the curve fitting represents the ...

2006-12-15

465

Photoconductive ultraviolet detectors based on ZnO films  

International Nuclear Information System (INIS)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant #tau# obtained from the curve fitting represents the ...

2006-12-15

466

Photoconducting properties of ultraviolet detectors based on GaN and Al{sub 1{minus}x}Ga{sub x}N films grown by ECR-MBE  

Energy Technology Data Exchange (ETDEWEB)

GaN and Al{sub 1{minus}x}Ga{sub x}N films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10{sup 9} ohm-cm and 10{sup {minus}3}--10{sup {minus}8} cm{sup 2}/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.

1997-12-31

467

Photoconducting properties of ultraviolet detectors based on GaN and Al_1_-_xGa_xN films grown by ECR-MBE  

International Nuclear Information System (INIS)

GaN and Al_1_-_xGa_xN films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10"9 ohm-cm and 10"-"3--10"-"8 cm"2/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.

1996-12-02

468

Performance assessment for EEG-based neonatal seizure detectors  

UK PubMed Central (United Kingdom)

ObjectiveThis study discusses an appropriate framework to measure system performance for the task of neonatal seizure detection using EEG. The framework is used to present an extended...Full Text Available

2011-03-01

469

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the ...

1999-07-01

470

Online processing in the ALICE DAQ The detector algorithms  

CERN Document Server

ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...

2010-01-01

471

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

Energy Technology Data Exchange (ETDEWEB)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

1983-01-01

472

On-line real-time measurements of decontamination factor for a low-level waste incinerator  

International Nuclear Information System (INIS)

The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.

473

Novel remote sensing gas outburst detector  

Energy Technology Data Exchange (ETDEWEB)

The possibility has been explored of using a laser scattering technique to detect the imminent onset of rock activity associated with gas outbursts. The instrument described in this paper provides a sensitive, remote and rapid means of passively monitoring micro-seismic activity at the exposed face.

1984-08-01

474

Monte Carlo modeling of 60Co HDR brachytherapy source in water and in different solid water phantom materials  

UK PubMed Central (United Kingdom)

The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available

2010-01-01

475

Midwave infrared type-II InAs/GaSb superlattice detectors with mixed interfaces  

Science.gov (United States)

We report the growth and fabrication of midwave infrared InAs/GaSb strain layer superlattice (SLS) detectors. Growth of alternate interfaces leads to a reduced strain between the GaSb buffer and SLS ({delta}a{sub parallel}/a=-5x10{sup -4}), enabling the growth of active regions up to 3 {mu}m (625 periods). The structural, optical, and electrical properties of the active region were characterized using x-ray crystallography and photoluminescence, respectively. p-i-n detectors were grown using 625 periods of 8 ML (monolayer) InAs/8 ML GaSb as the active region. The {lambda}{sub cutoff} for the detectors was 4.6 {mu}m with a conversion efficiency of 32% at V{sub b}=-0.2 V. Detectivity was obtained using noise power spectral density measurements under 300 K 2{pi} field of view illumination and was equal to 5.2x10{sup 10} and 3x10{sup 10} cm Hz{sup 1/2}/W (V{sub b}=-0.02 V, T=80 K) in the white noise and 1/f noise limit (at 50 ...

2006-07-01

476

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.

2001-05-01

477

MAGIC - Multi Anode Gas Ionization Chamber  

Energy Technology Data Exchange (ETDEWEB)

A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))

1994-12-01

478

Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences  

Science.gov (United States)

The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)

1973-08-01

479

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; ...

1982-12-01

480

Indoor radon concentration measurements by using SSNTD  

International Nuclear Information System (INIS)

In this paper, some results of the indoor radon concentration measurements are presented. Kodac track detectors LR 115, bare and in a cup were used for these measurements. Average winter/summer ratio was determined for the town of interest. (author). 5 refs, 1 fig., 1 tab.

481

Indoor radon concentration measurements  

International Nuclear Information System (INIS)

Some results of the indoor radon measurements are presented in this paper. Kodac track detectors LR-115 were used for these measurements. Average winter/spring ratio for indoor radon concentration was determined from the results obtained and is presented in this paper. (author).

482

Front-End-Electronics Communication software for multiple detectors in the ALICE experiment  

Energy Technology Data Exchange (ETDEWEB)

In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps ...

2006-02-15

483

Forschungszentrum Juelich, Institut fuer Kernphysik/COSY. Annual report 2004  

Energy Technology Data Exchange (ETDEWEB)

The following topics are dealt with: Detectors at COSY, major physics results at COSY, physics at external facilities, theoretical investigations, COSY operation and developments, preparations for FAIR, technical developments. (HSI)

2005-03-01

484

Feynmann variance-to-mean method  

Energy Technology Data Exchange (ETDEWEB)

The Feynmann and other fluctuation techniques have been shown to be useful for determining the multiplication of subcritical systems. The moments of the counting distribution from neutron detectors is analyzed to yield the multiplication value. We present the methodology and some selected applications and results and comparisons with Monte Carlo calculations.

1985-01-01

485

Explosives detection The problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

Explosives molecules have a number of unique properties. These properties are discussed. They include low vapor pressures, electronegativity, ''stickiness,'' frangibility, and thermal instability. The program for developing an advanced explosives detector is described.

1984-07-01

486

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

487

Does DaYa-Bay Reactor Play an Important Role in Theta_{13} of Lepton Mixing (PMNS) Matrix ?  

CERN Document Server

Reactor neutrinos play an important role in determining parameter theta_{13} in the lepton mixing (PMNS) matrix. Next important step on measuring PMNS matrix could be to build another reactor neutrino experiment in DaYa bay, China, to search the possible oscillations via sin^2 (2theta_{13}) and Delta m^2_{13}. We consider 4 different schemes for positions of three 8-ton detectors of this experiment, and simulate the results with respect to an array of assumed ''true'' values of physics parameters. Using three kinds of analysis method, we suggest a best scheme for DaYa-Bay which is to place a detector 2200m ~ 2500m symmetrically away from two reactors, and to put the other two detectors closer to their corresponding reactors respectively, almost at a 100m \\~ 200m distance. Moreover, with conservative assumption on the experimental technique, we construct series of allowed regions from our simulation results, and give ...

2004-01-01

488

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

489

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

490

Daya Bay Neutrino Experiment  

CERN Document Server

The Daya Bay Neutrino Experiment is proposed to measure sin^2(2\\theta_{13}) to better than 0.01 at 90% C.L. in a three-year run. The experimental site, detector design, and background estimation are presented.

2006-01-01

491

Construction of a open-quotes black neutron detectorclose quotes at the University of Massachusetts-Lowell Accelerator Laboratory  

International Nuclear Information System (INIS)

In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The ...

1992-03-16

492

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to ...

2009-06-07

493

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed boron-lined ...

2009-11-02

494

Black holes as detectors of tachyons  

International Nuclear Information System (INIS)

Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).

495

Angular sensitivity distribution of detectors for BNCT  

Energy Technology Data Exchange (ETDEWEB)

The research on the therapy of brain tumors and others by the thermal neutron irradiation using research reactors is to kill tumor cells by accumulating boron at a tumor part, and using {alpha} particles and {sup 7}Li generated by {sup 10}B(n, {alpha}){sup 7}Li reaction of thermal neutrons, which is known as boron neutron capture therapy (BNCT). In Japan Atomic Energy Research Institute, the medical irradiation facility was installed in the thermal neutron column of the JRR-2, and as of March, 1994, 22 cases of irradiation have been carried out. In order to monitor the variation of thermal neutron flux during irradiation, the real time measurement using a simultaneous monitor is carried out, but there is the variation of measured values in the Si semiconductor, p-n junction detector possibly due to its direction dependence. The experiment was carried out to quantity the direction dependence of the detector by using the neutron radiography ...

1995-03-01

496

Search for tachyons associated with extensive air showers in the ground level cosmic radiation  

International Nuclear Information System (INIS)

Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.

1985-08-01

497

Radiation-annealing hardening of vanadium  

International Nuclear Information System (INIS)

Mechanical properties of vanadium, irradiated with fast neutrons up to 8.6x10"-"4 dpa depending on postirradiation annealing temperature, are studied. It is shown that radiation-annealing hardening (RAH) is observed at 300 deg C, which agrees with earlier performed studies. It is first stated that RAH is accompanied by plasticity decrease. Phenomenological model permitting to explain RAH dependence on irradiation temperature and dose and also on content of chemically active alloying impurities is suggested.

498

Molecular dynamics simulation of nanoctrystalline nickel: structure and mechanical properties  

Energy Technology Data Exchange (ETDEWEB)

Molecular dynamics computer simulations of a dense nanocrystalline Nickel sample are performed on the parallel Cray T3 (EPFL-Lausanne). The sample contains 50 grains with an average size of 3 nm. By perturbing the relaxed configuration elastic and plastic properties are studied. (author) 1 fig., 1 ref.

1996-10-01

499

Koyo engineering journal, No. 147, April 1995. Special issue on automotive bearings and applicable products  

Energy Technology Data Exchange (ETDEWEB)

Special Issue on Automotive Bearings and Applicable Products; Reports include Performance of Ceramic Cam Roller Follower for Automotive Engine; Performance of Drawn Cup Needle Roller Bearing for Propellershaft; Plastic Bearing Retainer for High Temperature Oil Lubrication; Bearing Device for Vehicle Axle; and Flush Mounting Type Programmable Cam Switches.

1995-12-31

500

Food-packaging materials: migration of constituents into food contents. January 1982-December 1988 (Citations from Packaging Science and technology Abstracts data base). Report for January 1982-December 1988  

International Nuclear Information System (INIS)

This bibliography contains citations concerning the migration of food-packaging materials into foods. Plastic, glass, cardboard, metal, and ceramic containers are discussed. Techniques for analyzing packaging contamination are included. (Contains 90 citations fully indexed and including a title list.).