Tendon reconstruction using grafts often results in adhesions that limit joint flexion. These adhesions are precipitated by inflammation, fibrosis, and paucity of tendon differentiation signals...Full Text Available
Objective: Hamstring injuries can be quite debilitating and often result in chronic problems. Eccentric muscle actions are often the last line of defense against muscle injury...Full Text Available
The present paper dealt with the extension of tendon friction coefficient correlation as a function of loading end load and circumferential angle, proposed in the former paper. The extended correlation further included the effects of the number of strands contacted with sheath, tendon diameter, politicization of tendon and tendon local curvature. The validity of the correlation was confirmed by several published measured data. The structural analysis of middle cylinder part of 1/4 PCCV (Prestressed Concrete Containment Vessel) model was conducted using the present friction coefficient correlation. The results were compared with the analysis using constant friction coefficient, focused on the tendon tension force distribution. (author)
BackgroundHamstring injuries are the most common injury in Australian Rules football. It was the aims to investigate whether a sports chiropractic manual therapy intervention protocol...Full Text Available
A 33-year-old man sustained an acute Achilles tendon rupture which was surgically repaired. Early nonweight-bearing range of motion and strengthening of the ankle and the repaired muscle unit was allowed...Full Text Available
BackgroundFourier Transform Infrared Imaging (FTIRI) is used to investigate the amide anisotropies at different surfaces of a three-dimensional cartilage or tendon block. With the...Full Text Available
A powerlifting athlete ruptured his left tendon of the pectoralis major muscle while attempting to lift 160 kg in a Brazilian bench press championship. The injury seemed to occur in the concentric...Full Text Available
Two patients, treated for blunt thoracoabdominal trauma with ruptured diaphragm and concomitant avulsion of the pericardial sac in its entirety from the central tendon of the diaphragm, are presented. We do not think this entity has been reported before. We explain this type of lesion on the basis of embryological development of the pericardium at the level of the central tendon of the diaphragm. PMID:15302069
A sulfonated fluoroalkyl graft polymer (FGP) membrane was prepared as a polymer electrolyte. First, the FGP membrane was grafted with styrene under UV irradiation. The grafted FGP was then sulfonated to functionalize it for proton conductivity. The grafting degree of the membrane increased with increasing grafting time during UV irradiation. The proton conductivity of the membrane increased with increasing grafting degree. The swelling ratio was independent of the grafting time, however, the water uptake increased with increasing grafting degree. Based on these results, it was found that the UV-initiated styrene grafting occurred along the membrane thickness direction. Moreover, the membrane was embedded within the glass fibers of the composite. This composite electrolytic membrane had 1.15 times the ...
The circulation in microvascularized rib grafts has been compared with that in conventional rib grafts and in those augmented by a direct vascular bundle implantation into the bone grafts. A new experimental model has been designed to correlate vascular perfusion, bone scan patterns, tetracycline labeling, and histological findings in these bone grafts. Posterior microvascularized rib grafts were found to have a circulatory pattern identical to that of the normal rib. Failed microvascularized rib grafts were revascularized more slowly than conventional rib grafts. Vascular bundles implanted into rib grafts remained patent and increased the rate of revascularization. The stripping or preservation of periosteum had no observable effects on the rate or pattern of conventional rib graft ...
Compliance mismatch is a significant challenge to long-term patency in small-diameter bypass grafts because it causes intimal hyperplasia and ultimately graft occlusion. Current engineered grafts...Full Text Available
BackgroundThe survival of hemodialysis patients requiring dialysis depends on the long-term functioning and patency of the vascular access. Prosthetic vascular grafts are inevitably...Full Text Available
BackgroundSensory information from mechanoreceptors in the skin, muscles, tendons, and joint structures plays an important role in joint stability. A joint injury can lead to disruption...Full Text Available
Craniofacial injuries require a variety of different cell types to repopulate areas of bone, cartilage, tendon, and fat. Mesenchymal stem cells (MSCs) provide a multipotent cell source for tissue...Full Text Available
Equinovarus of the foot is the most common lower extremity deformity following traumatic brain injury. We evaluated outcomes of the split anterior tibialis tendon transfer (SPLATT) for correction of...Full Text Available
Patellar tendon autografts are not suitable for multibundle ACL reconstruction, a procedure that reportedly enhances postoperative knee stability. Biomechanical studies recommend lateral placement of...Full Text Available
Background: Contamination of autologous grafts unfortunately occurs in plastic surgery, but the literature provides no guidance for management of such incidents. Methods: American...Full Text Available
Purpose: To evaluate the effect on dilatation of three types of covering materials used for endovascular stent-grafts.Methods: Stent-grafts with three types of covering material [0.1-mm polytetrafluoroethylene (PTFE), 0.2-mm PTFE, and 0.15-mm woven polyester] were placed in a fluid circuit. For the pulsatile pressure test, the luminal pressure of 190/130 mmHg was loaded up to 300,000 pulses. For the static pressure test, the luminal pressure was increased from 50 to 300 mmHg at 50-mmHg increments. The percent of dilatation of each stent-graft was compared.Results: The 0.1-mm PTFE stent-graft was significantly more dilated than the 0.2-mm PTFE and the 0.15-mm woven polyester stent-graft (p < 0.005) in both examinations. There was no significant difference between the 0.2-mm PTFE and the 0.15-mm woven polyester stent-grafts. The dilatation of the 0.1-mm PTFE ...
Eight patients with double-velour Dacron aorto-femoral grafts implanted for 2-60 months were studied. Indium-111-labelled platelets were found to have a shortened mean platelet lifespan (MPLS) of 138 +- 32 hours compared with the normal platelet lifespan of 224 +- 23 hours. Labelled platelets accumulated on all grafts, irrespective of graft age, to a maximum of 1,80 +- 0,83% of whole body radioactivity; thereafter graft radio-activity decreased. This suggests that platelets on the graft are in dynamic equilibrium with those in the circulation. Platelets may be lost from the graft by embolization or radioactivity may be released because of platelet lysis. Although MPLS may depend on the age and surface area of the graft, concomitant arterial disease probably also contributes to the shortened MPLS.
Purpose The aim of this study was to evaluate the role of host periosteum and recipient bed perforation on the healing of an onlay graft to the mandible based on histologic and immunohistochemical analysis. Materials and methods Each of the 12 adult sheep used in the study received four iliac corticocancellous onlay bone grafts on the lateral surface of the mandible. In experiment 1, the block graft was placed in direct contact with the recipient bed and fixed with micro-screws, and in experiment 2, the recipient cortical bed was perforated before graft placement. The host periosteum around the graft was excised before flap replacement in experiment 3, and in experiment 4, a sheet of silicone membrane was placed between the graft and the recipient bed. The animals were euthanised at 4, 8, ...
The objective of this study was to evaluate the role of collagen membrane and Bio-Oss coverage in healing of an onlay graft to the mandible. Twelve adult sheep each received an onlay bone graft (experiment 1), bone graft+Bio-Gide (experiment 2), and bone graft+Bio-Oss/Bio-Gide (experiment 3) on the lateral surface of the mandible. The animals were euthanized at 4, 8, 12 or 16 weeks after surgery, and findings were analysed by routine microscopy and immunohistochemistry for proliferation (Ki67) and apoptotic (Caspase-3) markers. Grafts were fully incorporated in all specimens. Pronounced resorption was observed in experiment 1. Minimal loss of graft volume was seen in experiment 2 specimens without membrane displacement. A remarkable increase in the augmented region of the mandible was obse...
sup(99m)Tc-MDP bone scintigraphy was performed on patients who received muscle-pedicle bone graft. In each of the bone head and the bone graft, a time-activity curve was obtained. In this muscle-pedicle bone graft, active revascularization and marked osteogenesis, which suggested rapid bone repairing, were observed. The bone scintigraphy was considered to be useful in observing the result of bone grafts, blood circulation, and time of bone fusion, and of value for early detection of secondary changes.
Equinovarus of the foot is the most common lower extremity deformity following traumatic brain injury. We evaluated outcomes of the split anterior tibialis tendon transfer (SPLATT) for correction of equinovarus in 47 patients with hemiplegic traumatic brain injury and specifically studied differences in outcomes with two tendon fixation techniques. Seventeen patients constituting Group I underwent fixation with one technique and 30 constituting Group II had another technique. Patients in both groups had appropriate procedures based on dynamic electromyography and gait analyses. Both groups were demographically comparable. All 47 feet were corrected to plantigrade position. Thirty-six of 47 patients became brace-free at final followup. There was a notable decrease in the use of ambulatory aids and ambulatory status improved in both groups. There were three fixation-related complications in Group I and none in Group II. Surgical correction of the ...
Previous reports have stressed the importance of the nutrient blood supply in rib grafts transferred by microvascular anastomoses. In the present experimental study, we have demonstrated that a rib graft transferred by microvascular anastomoses based on periosteal vessels can survive; vascular clearing studies demonstrated that the vascularity of these grafts extends not only into the cortex but the medulla as well. The relative facility of harvesting these grafts (compared with those based on nutrient vessels) should make them the favored choice. Technetium bone scintigraphy proved accurate in the assessment of both vascular pattern and microanastomotic patency. Tetracycline labeling did not correlate well with the patency of a rib graft's pedicle blood supply.
The purpose of this study was to investigate whether hydroxyapatite (HAp) coating could induce polyethylene terephthalate (PET) artificial ligament graft osseointegration in the bone tunnel. Twenty-four New Zealand white rabbits underwent artificial ligament graft transplantation in bilateral proximal tibia tunnels. One limb was implanted with HAp-coated PET graft, and the contralateral limb was implanted with non-HAp-coated PET graft as control. The rabbits were randomly sacrificed at four and eight?weeks after surgery. The loads to failure of the experimental group at eight?weeks were significantly higher than those of the control group (p?=?0.0057). Histologically, application of HAp coating induced new bone formation between graft and bone at eight?weeks compared with the controls. Rea...
Radiation modification on liquid retention properties of native cassava starch, gelatinized at 85"0C, by graft copolymerization with acrylonitrile was carried out by mutual irradiation to #gamma#-rays. A thin aluminium foil was used to cover the inner wall of the reaction vessel so that the extent of homo polymer could be reduced to be less than 1.6% with a distilled water retention value of 665 g/g of the dry weight of the saponified grafted product. Confirmations of graft copolymerization and saponification reactions were made by the infrared spectrophotometric technique. The combined effect of radiation parameters in terms of an irradiation time and a dose rate to the same total dose on the extent of grafting reaction expressed in terms of grafting parameters which directly influenced liquid retention values was evaluated in conjunction with statistical analysis.
Spastic equinovarus foot deformity commonly occurs after stroke or head trauma. Management by split anterior tibial tendon transfer to the lateral border of the foot was chosen by the authors. The purpose of that work was to assess the reliability of this method to improve patient's functional autonomy and investigate the relationship between the initial clinical examination findings and the quality of the functional results. 84 feet, operated in 82 patients out of 130, of mean age 46 years, were reviewed at a mean follow-up of 65 months. Very few complications were observed. Toe deformities remain a commonly associated problem. 80 patients were able to walk barefoot, 74 reported an increase in their walking distance, and 73 could regularly wear normal shoes. There is a strong relationship...
Equinovarus of the foot is the most common lower extremity deformity following traumatic brain injury. We evaluated outcomes of the split anterior tibialis tendon transfer (SPLATT) for correction of equinovarus in 47 patients with hemiplegic traumatic brain injury and specifically studied differences in outcomes with two tendon fixation techniques. Seventeen patients constituting Group I underwent fixation with one technique and 30 constituting Group II had another technique. Patients in both groups had appropriate procedures based on dynamic electromyography and gait analyses. Both groups were demographically comparable. All 47 feet were corrected to plantigrade position. Thirty-six of 47 patients became brace-free at final followup. There was a notable decrease in the use of ambulatory a...
A new strategy is presented for the synthesis of graft copolymers using only the ring-opening metathesis polymerization (ROMP). From a ROMP-derived main chain, pendant maleimide functional groups...Full Text Available
Thin PTFE membranes were prepared by coating the PTFE dispersion onto the aluminum films. Thus the thin crosslinked PTFE (RX-PTFE) membranes were obtained by means of electron beam irradiation above the melting temperature of PTFE under oxygen-free atmosphere. The RX-PTFE membranes were pre-irradiated and grafted by styrene with or without divinylbenzene (DVB) in liquid phase. The existence of DVB accelerated the initial grafting rate. The styrene grafted RX-PTFE membranes are white colored, on the other hand, the styrene/DVB grafted RX-PTFE membranes are colorless. The proton exchange membranes (PEMs) were obtained by sulfonating the grafted membranes using chlorosulfonic acid. The ion exchange capacity (IEC) values of the PEMs ranging from 1.5 to 2.8 meq/g were obtained. The PEMs made from the styrene/DVB grafted membranes showed higher chemical stability than ...
Aneurysms of saphenous vein grafts are rare but can result in complications such as myocardial infarction or death. Percutaneous treatment has included a variety of approaches, including covered stents....Full Text Available
A method of grafting lignin-containing materials is now known which allows 1-phenylethylene or 4-methyl-2-oxy-3-oxopent-4-ene graft copolymers of wood to be quantitatively made. Graft copolymer is formed by conducting a free-radical polymerization with 1-phenylethene in nitrogen-saturated, organic or aqueous/organic solvent containing a lignin source, calcium chloride, and a hydroperoxide. Grafting changes solubility and surface properties of the wood. The lignin-containing materials grafted are unbleached wood pulps produced by chemical, thermal, and mechanical pulping. Grafting wood pulp produces a wood-reinforced, thermoplastic composite. When a particular plastic is to be blended with wood, we react the wood with the monomer used to make that plastic. This creates a hydrophobic surface of the plastic on the wood. This plastic coating can readily bond to the ...
In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the ..beta.. chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.
In the synthesis of the peptidyl-polymer corresponding to the sequence (57-100) of the #beta# chain of human hemoglobin on Teflon with radiationally grafted polystyrene a comparative study was made of different methods of fragment condensation. It was shown that the most effective methods are azide condensation and condensation with the use of complex F.
This paper explores for the first time the post-radiation-induced-graft polymerization on solid substrate using reversible addition-fragmentation transfer (RAFT) mechanism. Radiation-induced graft polymerization onto polymers is a potentially interesting technique to create easily new materials from highly resistant polymers, e.g. surface graft polymerization of acrylic acid (AA) onto poly(vinylidene difluoride) (PVDF) improves its surface properties without losing its excellent mechanical properties. As a consequence of the radical nature of the polymerization processes it is difficult to control molecular weight of grafted chains, and therefore design and standardize the properties of the final product. RAFT polymerization is a suitable method to obtain monodisperse polymers. The ability of the RAFT agents to control the polymer chain length could be an interesting approach to improve the ...
Abstract Objective: To compare the vertical dimensional changes with regard to graft height in a long-term follow-up in patients treated with two different grafting materials used in maxillary sinus floor elevation procedures. Material and methods: Twenty consecutive patients were included. One group was grafted with autogenous bone from the mandible (chin area), and the other group was augmented with a 100%b-tricalcium phosphate (b-TCP). During a 4- to 5-year period, in each patient, at least five panoramic radiographs were made. These panoramic radiographs were used for morphometric measurements, at three different locations. The three locations were the first bone to implant contact at the distal side of the second most posterior implant (L1), halfway between this implant and the most p...
Graft copolymerization of sodium styrene sulfonate (SSS) onto electron beam (EB) irradiated poly(vinylidene fluoride) (PVDF) films was investigated to find out a simple preparation process for sulfonic acid proton exchange membranes with respect to monomer concentration, absorbed dose, temperature, film thickness and storage time. The reaction order of the monomer concentration and absorbed dose of grafting was found to be 2.84 and 1.20, respectively. The overall activation energy for graft copolymerization reaction was calculated to be 11.36 kJ/mol. The initial rate of grafting was found to decrease with an increase in the film thickness. The trapped radicals in the irradiated PVDF films remained effective in initiating the reaction without considerable loss in grafting level up to 180 days, when stored under -60 {sup o}C. The presence and distribution of polystyrene sulfonate ...
Conditions for radiation induced grafting with butyl acrylate dispersed in water emulsion onto chrome-tanned pig skins have been worked out for #gamma#-rays and electron beam irradiations. The highest yield of grafting was observed at monomer concentration approximately 25% (w/w), dose equal to 25 kGy and dose rate not exceeding 10 MGy/h. At these conditions the yield of grafting attained a value approximately 25% and content of homopolymer in the leather amounted to 6%. The efficiency of monomer to polymer conversion decreases when the concentration of monomer in emulsion and dose rate increases. Yield of homopolymer is independent of the dose rate. An explanation of the observed relations has been proposed. The physical and used properties of grafted leathers were tested. Radiation processed leathers were found superior to samples finished by traditional methods. One has to point to better tolerance ...
The prospective study includes 25 patients without pathology of the femoral head for the evaluation of the normal femoral head perfusion. In addition 34 patients with femoral head necrosis underwent i.a. DSA preoperatively before pedicled pelvic bone grafting. 15 patients after pelvic bone graft operation and 7 patients with medial femoral head fracture were also examined via superselective DSA. In cases with femoral head necrosis a rarefaction or interruption of the rami nutricii proximales, or an occlusion of the medial circumflex femoral artery were observed. Patients with medial femoral neck fracture showed an interruption of the rami nutricii proximales of the femoral head. Postoperative DSA - after pedicled pelvic bone graft - revealed a regular arterial graft perfusion in 82%. (orig.).
The synthetic process of polyethylene cation exchange capillary via radiation grafting polystyrene by simultaneous irradiation with "6"0Co #gamma#-ray source and sulfonation with concentrated H_2SO_4 was studied. The effects of dose, dose rate, monomer concentration, solvents, temperature and crosslinking agents on the graft copolymerization of styrene with polyethylene capillary were illustrated. The relationship between the radiation grafting conditions and the properties of ion-exchange capillary were examined. A polyethylene cation exchange capillary with I.D. 0.8 mm, length 20 m, exchange capacity 0.7 Meq/g 60% capacity in 10 s (flow rate 20 ml/min) was prepared. No significant loss of copacity was found from this ion-exchange capillary after 200 adsorption/regeneration cycles.
We have developed a chitosan/polyglycolic acid (PGA) artificial nerve graft which was previously used for bridge implantation of dog sciatic nerves across 30-mm long defects. Here we describe a clinical trial of this graft for repairing a 35-mm-long median nerve defect at elbow of a human patient. During the 3-year follow-up period, functional recovery of the injured median nerve was assessed by pinch gauge test, hydraulic hand dynamometry, static two-point discrimination and touch test with monofilaments, in couple with electrophysiological examinations. The motor and sensory function of the median nerve demonstrated an ongoing recovery postimplantation, reaching M4 and S3+ levels during the follow-up period. The results indicate that the chitosan/PGA artificial nerve graft could be used ...
The development of 'Green Chemistry' requires new materials to replace the conventional organic chemistry by biological catalysts, to produce fine chemicals in an environmentally friendly manner. Microbial whole cells can be directly used as biocatalysts, providing a simple and cheap methodology since enzyme isolation and purification are avoided. High-density polyethylene (HDPE) is a very stable polymer though it can be activated by gamma radiation to induce grafting. Glycidyl methacrylate was grafted onto macroporous HDPE and PP in the range of 1-6%, proportional to the initial monomer concentration. Grafted polymers were further chemically modified with ethylenediamine to generate a cationic hydrogel of micron-size thickness onto the internal polymer surfaces. Modified polymers were able to immobilize Gram-positive and Gram-negative bacteria that can catalyze a chemical reaction as efficient as free ...
The influence of chemical and solvent extraction compatibilising techniques on the mechanical properties of poly-lactic acid (PLA) and MaterBi-polyester (PEM) based bio-composites are compared. First, fibres were chemically grafted with two fatty chains: stearic anhydride and octadecylisocyanate. Grafted fibres were characterised by FTIR and elemental analyses. Contact angle measurements show the hydrophobisation of the fibres in spite of very low surface grafting. Extracted and non-grafted fibres were prepared to be used as references. PEM and PLA-based composites with 30% w/w were prepared by compression moulding. Their mechanical properties were studied. It was found that chemical and solvent treatment of the fibres improved the reinforcement effect in the case of a PEM matrix and the Y...
The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous ...
The application of photopolymerisation (UV) and electron beams (EB) technologies in radiation rapid cure (PRC) processing is discussed. The chemistry associated with such reactions and the mechanisms of the processes are treated. The occurrence of concurrent grafting to substrate with radiation curing of films is shown to be an advantage in enhancing the properties of certain finished products. The parameters influencing the optimum grafting yield in such PRC processes are discussed. In many applications, the chemistry of such processes combined with the machine, specially for EB is shown. (author).
As an alternative to surgery, endovascular therapy with stent grafts has become the second main treatment option for infrarenal abdominal aortic aneurysms. Unlike surgery, endovascular treatment with stent grafts is also applicable in patients unfit for open repair. Despite current improvements in endovascular repair devices, significant anatomic barriers still exclude this technique for a large number of patients. Computed tomography, magnetic resonance imaging, and ultrasound are essential for diagnostics, preintervention planning, and postintervention follow-up of abdominal aneurysms treated with stent grafts. This review covers etiology, pathology, and diagnostic aspects. Materials and methods for endovascular treatment of abdominal aortic aneurysms are presented in detail, and clinical results and complications are discussed. (orig.) [German] Die endovaskulaere Therapie des infrarenalen Bauchaortenaneurysmas hat sich ...
We report for the first time a case of a 54 years old man with a fatal motorcycle accident due to an external bleeding compression of left internal mammary artery graft to the left anterior descending...Full Text Available
Infections of aortoarterial prostheses are serious, difficult to detect, and difficult to treat. Scintigraphy with indium-111 labeled autologous leukocytes is an accurate noninvasive method of assessing the presence and extent of such an infection. In three cases of aorto-arterial bypass graft infections, the leukocyte study was successful in establishing the diagnosis and in assessing the extent of infection. Other noninvasive diagnostic techniques are useful, but all have serious limitations. The leukocyte study alone appears to be free of likely sources of error.
Background:Acute Coronary Syndrome (ACS) can occur in patients with prior coronary artery bypass grafting (CABG). In the Gulf Registry of acute coronary events (Gulf RACE), we identified...Full Text Available
Platelet-rich plasma (PRP) is a platelet concentrate that has widely been used to accelerate the healing of soft and hard tissues. The preparation of PRP has been described by several authors. Preparation protocols vary from system to system, depending on the concentration of different integrating proteins. The objective of this article is to describe the principal use of PRP mixed with fat grafts in aesthetic plastic surgery.
The purpose of this study was to evaluate the feasibility, efficacy and safety of percutaneous thromboaspiration with a Desilets-Hoffman Sheath compared with the previously established percutaneous mechanical thrombectomy technique in cases of occluded dialysis graft. One hundred and sixty eight patients (103 women, 65 men; mean age, 54.7 years; mean graft age, 20.9 months) with 225 episodes of dialysis graft thrombosis underwent percutaneous thromboaspiration with a 7F Desilets-Hoffman sheath using the crossing catheter or single puncture technique. The technical success rate, procedure time, and complication and patency rates were analyzed. Technical success was achieved in 200 of the 225 procedures (88.9%). The average duration of the intervention was 74.3 {+-} 35 minutes. The primary patency rate was 63.1% at 3 months, 44.2% at 6 months and 26.3% at 1 year. Major complications occurred in 4% of the cases (4 venous ...
Acrylonitrile electropolymerization (in an aprotic and anhydrous medium) has been used as a way to build thin, homogeneous and covering polyacrylonitrile layers grafted on the surface of usual metals and specially on copper-based shape memory alloy: Cu-Zn-Al. The results of the study first confirm the possibility of grafting thin and covering polyacrylonitrile layers on Cu-Zn-Al surface. The morphology of the films however is influenced by the geometry of the polycristalline structure of the alloy and its superficial defects. Samples obtained after grafting polyacrylonitrile films were submitted to corrosion tests based on Electrochemical Impedance Spectroscopy (EIS) measurements in a NaCl/H{sub 2}O medium. Results show that some post-treatments of the grafted films are necessary to improve their protective role, while preserving the strong interfacial bondings. Actually, thermal and mechanical cycling ...
We have presented evidence that the functional thyroid follicles (follicular units, FU) which are formed in grafts of monodispersed rat thyroid cells, and hence the thyroid tumors which later develop in such grafts, are clonal in origin. Recent studies have been designed to investigate: whether cell number-dependent inhibition of promotion-progression is mediated by remote hormonal feed-back, local cell-cell interactions, or both; the cell population kinetics of the clonogen subpopulation during goitrogenesis and goiter involution; and the effect of prolonged exposure to high levels of TSH (thyrotropin) on the capacity of the clonogens to give rise to functional FU. The results indicate that local cell-cell interactions play an important role in the cell number-dependent suppression of neoplastic promotion-progression. They also show that if sufficient thyroid cells are grafted, the thyroid-pituitary axis can be ...
Effect of oil palm empty fruit bunch (OPEFB) fiber and poly(methyl acrylate) grafted OPEFB on several mechanical properties of poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blends using HAKEE Rheomixer at the rotor speed of 50 rpm, mixing temperature 150degreeC, and mixing period of 20 min. The fiber loadings were varied from 0 to 30% and the effect of fiber content in the composites on their ultimate tensile strength (UTS), Youngs modulus, elongation at break, flexural modulus, hardness, and impact strength were determined. An increasing trend was observed in the Youngs modulus, flexural modulus, and hardness with the addition of grafted and ungrafted fiber to the PVC/ENR blends. However the i...
Sinus lifting and reconstruction of localized alveolar defects are often required after closure of a large oroantral fistula (OAF) to allow for subsequent implant installation. This study describes a combined surgical technique that involves sinus lifting, bony closure, and reconstruction of the alveolar defect at the site of an OAF. The sinus membrane was reconstructed as a continuous layer by combining the residual sinus membrane with a rotated part of oral mucosa around the OAF. Autogenous bone from the chin and/or ramus was grafted into the prepared sinus space and alveolar defect, and the graft was covered by a buccal advancement flap. This technique was used to treat 8 patients who had large OAFs in the posterior maxillary region. The treatment was successful in all cases, and the te...
In this work was made an assessment of the supramolecular structures presents into human breast tissue normal and pathological samples, as well as into two types of animals samples (tendon chicken and pork fat) using the small angle x-ray scattering (SAXS) technique. The scattering profiles of the samples were determined at the momentum transfer range O.150nm{sup -1}<=5:q(=4pi.sin({theta}/2)/{lambda})<=8.500nm{sup -1}. In this range, it was possible identify structures corresponding to collagen fibrils (glandular tissue) and to triacylglycerides (adipose tissue) from the correlation between the information extracted from the human breast tissues scattering profiles and those extracted from animals samples. (author)
A series of copolymers based on the cellulose acetate/propionate-g.co-acrylic acid system has been prepared under radiation-induced control. These copolymers have been assessed for their water-retention capacity both in an unmodified state and after ''decrystallization'' or ''neutralization'' treatments. The grafting of acrylic acid onto the cellulose acetate/propionate had little effect on the water retention power of the cellulose acetate/propionate. However, improvements to the water retentivity was obtained after ''decrystallization'' procedures had been carried out on the copolymers using selected alkali metal salts with methanol as the continuous medium. The water-retentivity of the copolymers increased with increase in the extent of grafting, though the effect is less pronounced at high graft levels. ...
The chloromethylation reaction of an asphaltite and styrene graft copolymer followed by the amination of the chloromethylated products was optimized. New strongly basic anion exchangers with an exchange capacity of 2.5 mg-equiv/g and a mechanical strength of 93% were prepared.
Successful implementation of bone marrow transplantation for hematopoietic reconstitution is limited by the lack of suitably HLA-matched donors and by the occurrence of graft-versus-host disease that...Full Text Available
Sudden unexpected postoperative hemodynamic collapse with a high mortality develops in 1–3% of patients undergoing coronary artery bypass surgery (CABG). The contribution of surgical graft complications...Full Text Available
In this work, coals of various ranks were dissolved in an acid melange. With the use of IR spectroscopy, it was found that the mechanism of coal dissolution consists in the grafting of polar groups to the peripheral benzene rings of graphite-like systems.
Many patients who undergo hematopoietic cell transplantation (HCT) present with anemia and have received red blood cell transfusions before HCT. As a result, iron overload is frequent and appears...Full Text Available
This prospective study describes and evaluates a surgical approach for 3D reconstruction of the posterior maxilla with autogenous mandibular bone in 16 patients (mean age 51 years). Bone blocks were harvested from the mandible and used as lateral or vertical block grafts (onlay); they were also partially milled and used for sinus elevation (inlay). In 4 cases, anorganic bovine bone was added at the periphery of the blocks. 4 months after grafting, implants were placed in a second operation and loaded after 12 weeks. Lateral and vertical augmentations were measured immediately after grafting and at re-entry for implant placement. Mean lateral augmentation performed was 5.5mm, reduced to 4.3mm (p<0.01) after 4 months' healing. Mean vertical augmentation was 3.2mm, reduced to 2.1mm (p<0.01) a...
The principal cause of primary non-function in orthotopic liver transplantation is thought to be preservation injury to the microvasculature. We, therefore, evaluated if effluent levels of hyaluronate,...Full Text Available
Porous Nitinol (PNT) has found vast applications in the medical industry as interbody fusion devices, synthetic bone grafts, etc. However, the tendency of the PNT to corrode is anticipated to...Full Text Available
Abstract Objectives: The purpose of this study was to evaluate the osseointegration of the dental implants placed into the mandible augmented with different techniques in pigs. Material and methods: Four adult domestic pigs were used. Horizontal augmentation of the mandible was performed in animals by using vascularized femur flap (VFF), non-vascularized femur graft (NVFG) and monocortical mandibular block graft (MG). After 5 months of healing 10 dental implants were placed into each augmented site. The pigs were sacrificed after 3 months of healing. Undecalcified sections were prepared for histomorphometric analysis. Results: Mean bone-implant contact (BIC) values for implants placed into MG, NVFG and VFF were 57.38 11.97%, 76.5 7.88%, 76.53 8.15%, respectively. The BIC values of NVFG and...
The cell types involved in the cellular immune response were studied with the GVH in vitro as a test system. Comparison of the activities of cells of different lymphoid organs in the...Full Text Available
PurposeThe aim of this study was to evaluate 3.5 years-cumulative survival rate of implants placed on augmented sinus using Osteon, a bone graft material, and to assess the height...Full Text Available
PurposeOcular surface disease following penetrating keratoplasty has been shown to increase patient morbidity and adversely affect graft survival. Five cases of dense central subepithelial...Full Text Available
Nitric oxide (NO)-based therapies effectively inhibit neointimal hyperplasia in animal models of arterial injury and bypass grafting, but are not available clinically. We created a simple, effective,...Full Text Available
A range of additives has been developed for enhancing grafting yields in a variety of systems initiated by ionizing radiation. Cellulose has been adopted as the predominant naturally occurring model backbone polymer in these studies because of its structural relationship to wood which is the reference substrate for the work reported in the related second part of this paper concerning composites. Some experiments have been performed with the other major naturally occurring polymer, wool. For comparison purposes with synthetic materials, some studies have also been performed with polypropylene as trunk polymer. Styrene has been used as a predominant monomer in grafting with some experiments utilizing the acrulates like methyl methacrylate. The role of solvent in grafting has been evaluated. UV has been used as initiator to replace ionizing radiation for certain experiments. The additives used were mineral acids, lithium ...
A 67-year-old man presented with gastrointestinal bleeding resulting from a fistula between the aortic stump and the fourth part of the duodenum 14 months after an axillobifemoral bypass, graft excision, and aortic stump closure for aortic graft infection. The patient initially refused any attempt at definitive surgical treatment so coil embolization of the aortic stump was performed via a brachial approach. Coil embolization may be a useful adjunct in the management of such difficult problems. This approach may buy time and allow careful planning of a definitive treatment or may serve as a palliative procedure in inoperable patients. PMID:15947052
The effect of additives on the grafting of a monomer, butylmethacrylate (BA), into simul (a soft wood) has been studied using {sup 60}Co source at 3 Mrad. The enhancement of polymer loading (grafting) by the addition of minute amounts (1%) of oligomers and of polyfunctional monomers into simul + BA system has been further increased in the presence of acid and urea. The synergistic polymer loading yields by acid addition cause substantial decrease of tensile strength values of wood-plastic composite; but urea increases both polymer loading and tensile strength values synergistically in these systems. (author).
The effect of additives on the grafting of a monomer, butylmethacrylate (BA), into simul (a soft wood) has been studied using "6"0Co source at 3 Mrad. The enhancement of polymer loading (grafting) by the addition of minute amounts (1%) of oligomers and of polyfunctional monomers into simul + BA system has been further increased in the presence of acid and urea. The synergistic polymer loading yields by acid addition cause substantial decrease of tensile strength values of wood-plastic composite; but urea increases both polymer loading and tensile strength values synergistically in these systems. (author).
The nature of radicals in wood irradiated in vacuum was studied by ESR method. The decay rate of radicals changes in three temperature ranges. Long-lived radicals are very stable at 298"0K, at which the wood-plastics composite has often been studied. The number of radicals formed by irradiations shows fairly good agreement with the total number of radicals in each isolated wood component. The graft copolymerization of MMA to irradiated wood was also studied by means of ESR, and it was found that PMMA propagating radicals are formed in irradiated wood. These radicals are probably formed by the result of graft copolymerization of MMA of wood. (auth.).
This paper studies the sorption of chlorine complexes of ruthenium (IV) on the graft copolymer of a polyacrylonitrile fiber with poly-2-methyl-5-vinylpyridine (PAN-MVP). The composition of the fiber is illustrated. It is shown that sorption of chlorine complexes of ruthenium (IV) from acid solutions by a pyridine fiber sorbent takes place according to an anion-exchange mechanism and is due to the formation of compounds of the diamine type (Ru(RPy)/sub 2/Cl/sub 4/).
Results are presented of trials in W. Germany involving Populus tremula X P. tremuloides. In a nursery in late August - early September 1971, some 1300 buds from 38 selected 3-yr-old hybrid aspen seedlings were grafted into T-slits at nodes 10-20 cm above root' collars of 1 and a half yr-old hybrid aspen stock (products of controlled crossings, and in some cases of similar parentage to the transplanted buds). In spring 1972, each stock (from which its own buds were removed) was cut back to a 'peg' 15-20 cm above the level of the graft; the 'peg' was later used to support the new shoot developed from the transplanted bud. By Sept. 1972, 33% of grafts were successful, the success rate being significantly different (3-67%) within clones; average height of scion shoots ranged from 79 to 375 cm (no significant difference between clones). In spring 1973, some 190 ...
The modification of polymers by radiation grafting has been utilized for several decades. The penetrability of gamma rays allows to modify the internal surfaces of porous materials retaining its mechanical properties. In recent years applications of these materials to obtain chromatographic supports and biocatalysts have been reported. In this work, we described the grafting of glycidyl methacrylate (GMA) onto a macroporous polysulfone polymer. Reproducible amount of grafting, from 10% to 60% was obtained by choosing favourable monomer concentration and gamma radiation doses from 6 kGy up. Afterwards, iminodiacetic acid (IDA) and amino phenyl arsine oxide (PAO) were covalently attached to the grafted polyGMA, in correspondence with the grafting degree. Later on, a recombinant histidin-patch thioredoxin protein (HP-rTrx) was immobilized onto this surface by two different ways, ...
Homologous and heterologous arterial segments were implanted in Fisher rats subcutaneously for the purpose of examining the antibody titer of the recipients' serum after implantation by means of the immune-adherence hemagglutination method. The antibody titer after implantation both of homologous and heterologous grafts decreased to 1/8 by 2.0 million (M) rads irradiation of high voltage cathode rays. The results suggested that high voltage cathode ray irradiation was not enough for heterologous graft to suppress its tissue reaction. Homografts taken from dogs 3 or 6 hours after sacrifice were irradiated with 2.0 M rads and transplanted in canine carotid artery using the technic of end-to-end anastomosis. Angiograms 6 months after operation revealed excellent patency rate in all the grafts of 28 dogs. furthermore, findings of the grafts from 1 week to 5 years after operation on scanning and ...
Homologous and heterologous arterial segments were implanted in Fisher rats subcutaneously for the purpose of examining the antibody titer of the recipients' serum after implantation by means of the immune-adherence hemagglutination method. The antibody titer after implantation both of homologous and heterologous grafts decreased to 1/8 by 2.0 million (M) rads irradiation of high voltage cathode rays. The results suggested that high voltage cathode ray irradiation was not enough for heterologous graft to suppress its tissue reaction. Homografts taken from dogs 3 or 6 hours after sacrifice were irradiated with 2.0 M rads and transplanted in canine carotid artery using the technic of end-to-end anastomosis. Angiograms 6 months after operation revealed excellent patency rate in all the grafts of 28 dogs. furthermore, findings of the grafts from 1 week to 5 years after operation on scanning and transmission ...
Eleven patients who had undergone cardiac surgery were studied by means of high-field MR imaging (1.5 T). Six patients had aortic root and valve replaced with a Bjork-Shiley (BS) composite tubular aortic graft prosthesis for acute dissection of ascending aorta. In the other 5 patients with rheumatic calcific aortic disease, the valve had been replaced with a BS prosthesis. As a whole, MR studies were 14. Previous evaluations of magnetic field effects had seem carried out ex vivo on both BS valves and BS composite prostheses, on surgical ligation clips (Tantalium and Stainless) and on stainless wires for sternal closure. In 4 patients (2 BS composite grafts, and 2 BS valves) MRI diagnosed chronic dissection of both arch and descending aorta. In 1 of them, with a bs valve, associated localized acute dissection of ascending aorta was observed. In 3 patients with BS composite grafts, MRI revealed pseudo-aneurysms (including a ...
Graft copolymers of methyl methacrylate and biodegradable, biocompatible bacterial poly([R]-3-hydroxybutyrate) (PHB) blocks were synthesized and evaluated as possible constituents in acrylic bone cements for use in orthopaedic applications. The copolymers were produced by conventional free radical copolymerization and incorporated in one commercially available acrylic bone cement brand, Antibiotic Simplex (AKZ). Cements with formulations containing 6.7 and 13.5 wt % of PMMA-graft-PHB were prepared. The morphology of the graft copolymer particles was suggested to influence the ability of the modified cement to be processed. Formulations containing more than about 20 wt % of the graft copolymer resulted in cement doughs that, both after first preparation and several hours later, were either sandy or soft spongy in texture and, thus, would be unacceptable for use in orthopaedic applications. The ...
PurposeThis prospective study followed 61 patients who were partially dentulous and considered to have insufficient bone volume for routine implant treatment and consequently underwent sinus inlay bone grafting.Patients and MethodsThe patients were treated with maxillary sinus floor augmentation with particulated autogenous bone from the mandibular ramus/corpus. After a healing period, dental implants (n = 180) were installed.ResultsRadiographic examination revealed average residual vertical bone heights of 6.5 mm in the first premolar region, 3.8 mm in the second premolar region, 3.5 mm in the first molar region, and 2.6 mm in the second molar region. The average implant lengths were 12 mm in the first premolar region and 11 mm in the second premolar, first, and second molar regions. All ...
Two local repair procedures, one without (9) and the other with (14) a bulbocavernosus muscle graft were performed on 20 patients with a radiation induced rectovaginal fistula. Four patients had two procedures successively. The initial success rate of both procedures was 7/9 and 14/14 respectively. Though the initial result of the bulbocavernosus graft was obviously better, in many of the local repair procedures, subclinical radiation damage progressed, resulting in recurrence of rectovaginal fistula (5), rectovesical fistula (4), pararectal abscess (2) etc. After a mean follow up of around 10 years, the success rate of fistula repair decreased to 5/9 and 13/14 and only 2/9 and 6/14 finally remained without a colostomy. A local repair operation should be restricted to carefully selected cases. The musculus gracilis is proposed as a better vascular graft. If the general condition of the patient does not allow more aggressive ...
Poster session: Abstract is full text. Track membranes are thin polymer foils irradiated by heavy ions. The defects created by the heavy ions are located along the ions trajectory, the track. It is possible to open channels by etching with a chemical agent. These channels are very uniform. Small Angle Scattering (of X rays and neutrons) give global information about the characteristics of the channel shape. As the nanochannels are strictly parallel, an excellent sample orientation is required to obtain interpretable spectra. Then shoulders due to the oscillations of the Bessel function (radial part of the channel shape Fourier transform) are easily seen in the scattered intensity in the PXY data treatment software of SAS spectra allow to determine the channel diameter with its dispersion law, to demonstrate the existence of a wall thickness with a linearly varying density, and to assess the roughness. PXY can also detect non cylindric shapes like single or double cones or spindles. ...
The effect of irradiation on the tensile properties of oil palm empty fruit bunch (OPEFB) fiber reinforced poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blend using HAAKE Rheomixer at 150 deg. C. The composites were then irradiated by using a 3.0 MeV electron beam machine at doses ranging from 0 to 100 kGy in air and room temperature. The tensile strength, Young's modulus, elongation at break and gel fraction of the composites were measured. Comparative studies were also made by using poly(methyl acrylate) grafted OPEFB fiber in the similar blend system. An increase in tensile strength, Young's modulus and gel fraction, with a concurrent reduction in the elongation at break (Eb) of the PVC/ENR/OPEFB composites were observed upon electron beam irradiation. Studies revealed that grafting of the OPEFB fiber with methyl acrylate did ...
Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although adherence to the present treatment protocol is considered to give ...
Purpose: To describe CT appearances in patients with unilateral cleft lip and palate (CLP) 20 years after bone graft surgery. Material and Methods: Eighteen consecutive patients with unilateral CLP were examined. All patients had been treated with primary closure, both in infancy and early childhood, supplemented with bone grafting at the age of around 10 years. The CT examination of the upper jaw included a dental CT program. The CT appearances of the cleft side were compared with those of the untreated non-cleft side. Results: Abnormal CT appearances included skew nasal aperture (n=17), nasal septal deviation (n=17), low floor of nasal aperture (n=15) at or towards the cleft side, and deviation of anterior nasal spine towards the non-cleft side (n=18). The posterior part of the bone cleft was visible in all patients, and the dental arch was V-shaped in 8. Conclusion: Although adherence to the present treatment protocol is considered to give ...
Natural, formaldehyde-treated and copolymer-grafted orange peels were evaluated as adsorbents to remove lead ions from aqueous solutions. The optimum pH for lead adsorption was found to be pH 5. The adsorption process was fast, reaching 99% of sorbent capacity in 10 min for the natural and treated biomasses and 20 min for the grafted material. The treated biomass showed the highest sorption rate and capacity in the batch experiments, with the results fitting well to a pseudo-first order rate equation. In the continuous test with the treated biomass, the capacity at complete exhaustion was 46.61 mg g{sup -1} for an initial concentration of 150 mg L{sup -1}. Scanning electronic microscopy and energy dispersive X-ray spectroscopy indicated that the materials had a rough surface, and that the adsorption of the metal took place on the surface. Fourier transform infrared spectroscopy revealed that the functional groups responsible for metallic ...
The authors present a comparison between the diagnostic accuracy of Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) in the articular pathologies of the knee. CT and MRI were performed in 30 patients who subsequently underwent surgery. CT and MRI results were compared on three bases: technique, definition of normal anatomy, and diagnostic accuracy. CT allowed a standardization of the technique, while MRI was superior in defining normal anatomy - especially in the study of capsulo-ligamentous structures. In all cases the use of both CT and MRI allowed a correct diagnosis, showing the site, extent and gravity of the lesion. CT proved to be superior to MRI in 4 cases, while MRI corrected CT diagnosis in 11 cases; in 15 patients both techniques had the same diagnostic accuracy. Meniscal tears were better identified by CT, while MRI was superior in the detection of ligamentous lesions and in the characterization of PVNS and tendinitis of the patellar ...
Hematopoietic stem cell transplantation provides the only potential curative option in many patients with hematological malignancies. Finding a suitably matched donor in a timely manner is often difficult. However, most patients have a partially HLA-mismatched (HLA-haploidentical) first-degree relative readily available. Historically, HLA-haploidentical bone marrow transplantation (BMT) has been considered extremely high risk due to high rates of life-threatening graft-versus-host disease (GVHD) and non-relapse mortality (NRM). Modifications of the stem cell graft, such as T-cell depletion, have resulted in poor rates of engraftment. We have recently completed a phase II clinical trial of nonmyeloablative HLA-haploidentical hematopoietic BMT followed by post-transplantation high-cyclophosp...
We prepared macromer-grafted polymers (MGPs) containing suitable polymer side chains for improving solubility and pyrene units for improving adsorption on multiwalled carbon nanotube (MWCNT) surfaces, and demonstrated that these MGPs act as MWCNT solubilizers that improve solubility of MWCNTs in typically poor solvents such as alkanes and that improve flowability of polymer/MWCNT composites. The polydimethylsiloxane (PDMS)-MGPs, synthesized using PDMS macromers and pyrene-containing monomers, improved solubility of MWCNTs not only in chloroform but also in hexane, which is a poor solvent for MWCNTs. Moreover, the addition of PDMS-MGP-adsorbed MWCNTs (MWCNT/PDMS-MGPs) to epoxy resin monomers or polybutylene terephthalate (PBT) drastically reduced the viscosity of the obtained epoxy resin mo...
The most advanced frontier of allogeneic hematopoietic stem cell transplantation (allo-HSCT) is represented by the use of an HLA-partially matched relative as donor. In this type of transplantation, donor-derived natural killer (NK) cells, which are alloreactive towardtoward recipient cells, significantly contribute to the eradication of leukemia blasts. Alloreactive NK cells may also kill host dendritic cells and T lymphocytes, thus preventing graft-versus-host disease and graft rejection, respectively. Sophisticated strategies of adoptive infusion of T-cell lines/clones specific for the most life-threatening pathogens (namely cytomegalovirus, Epstein-Barr virus, Aspergillus and Adenovirus) have been envisaged, and successfully tested in a few pilot trials, to protect the recipient in the...
Immune function is critical in health and disease. The control and regulation of immune reactions is an area of intense investigation that has important implications for allogeneic hematopoietic cell transplantation. Immune reactions are regulated in a number of important ways. Compartmentalization of immune responses and the production of both pro-inflammatory and anti-inflammatory cytokines play a major role. More recently several populations of T cells that regulate immune responses termed regulatory T cells have been identified. This manuscript will focus on CD4^+CD25^+FoxP3^+ natural regulatory T cells (T"r"e"g) and @a@bTCR^+CD4^+NK1.1^+ natural killer T (NK-T) cells which both suppress graft vs host disease but appear to function by distinct mechanisms.
Before electroless plating, polymer surfaces must be sensitized and/or activated by using either the conventional two-step or one-step process. The latter stage is a compulsory one to make such surfaces catalytic, e.g., for Ni-P deposition. These processes are performed here using O{sub 2}, NH{sub 3}, or N{sub 2} plasma pretreatments. Reaction mechanisms are proposed for each of the processes and for each type of surface considered (oxygenated or both oxygenated and nitrogenated by the plasma treatment). Direct palladium chemisorption onto nitrogenated groups is highlighted. This allows one to simplify the process making the surface catalytic via elimination of the use of SnCl{sub 2} and to extend the method to any polymer. An additional interest of the plasma treatments, besides their high efficiency in grafting chemical functions, is to perform this grafting at will on selected areas which results in selective metallization.
To evaluate the effectiveness of percutaneous mechanical declotting. Using a 7-F Desilets-Hoffman sheath and the crossed-catheter technique, we aspirated the intragraft clot and pushed the residual clot into the central circulation with balloon catheters. The success rate, procedure time, complications and patency rates were evaluated. Technical success was achieved in 24 of 32 cases, with a procedure time of 30-240 (average, 111) minutes. In five of eight cases in which technical failure occurred, the guide wire failed to reach the stenotic site and in the other three, there was insufficient luminal dilatation. Complications included vein ruptures (n=2), arterial emboli (n=1) and arterial dissection (1), but there was no evidence of clinical symptoms of pulmonary embolism. The six-month patency rate was 67.8%. Mechanical declotting of thrombosed dialysis graft using a balloon catheter is relatively inexpensive, safe and fast, and is well tolerated. (author)
Abstract Flame retardants (FRs) are used for in protection against fire. Organic inorganic hybrids could become one of the most promising FR solution in the future. In this paper, the synthesis, the characterization and the use as FRs and filler of grafted titania and alumina with 2 chloroethylphosphonic acid are presented. These hybrids contain 3.8 3.24% P and have good flame retardance when they are incorporated into unsaturated polyester resins. Alumina treated with 2 chloroethylphosphonic acid performed better than titania. The advantage of this approach is the use of these hybrid materials as filler and FR, in the same time, and the increase in flame retardancy by synergistic effect between alumina phosphorus and chlorine, for unsaturated polyester resins. Copyright 2010 John Wiley & ...
Tissue-engineered heart valves are prone to early structural deterioration. We hypothesize that cell?scaffold interaction and mechanical deformation results in upregulation of genes related to osteogenic/chondrogenic differentiation and thus changes extracellular matrix (ECM) composition in human bone marrow mesenchymal stem cell (hBMSC)-derived tissue-engineered grafts. hBMSC were expanded and seeded onto poly-glycolic acid/poly-lactic acid scaffold for 14 days. Seeded tissue-engineered constructs (TEC) were subjected to cyclic flexure for 24?h, whereas control TEC was maintained in roller bottles for the same duration. hBMSC, TEC, and mechanically deformed TEC were subjected to gene-array and histological analysis. Expression levels of RNA and/or protein markers related to chondrogenesis...
Atrial fibrillation (AF) is common after coronary artery bypass grafting (CABG) and increases the morbidity and cost. Amiodarone reduces AF after CABG. Ranolazine, an antianginal agent, also prolongs atrial refractoriness and inhibits after depolarizations and triggered activity; effects that could decrease AF after CABG. The present study compared amiodarone versus ranolazine for the prevention of AF after CABG. A retrospective cohort study of patients undergoing CABG at Aspirus Hospital from June 2008 to April 2010. The patients received either amiodarone (400 mg preoperatively followed by 200 mg twice daily for 10 to 14 days) or ranolazine (1,500 mg preoperatively followed by 1,000 mg twice daily for 10 to 14 days). The primary end point was any identified AF after CABG. A total of 393 ...
Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting. E.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for pretreated wood fibre ...
Composite materials of synthetics (based on monomers, oligomers and thermoplastics) and of natural polymers (wood and other fibrous cellulosics) prepared by radiation processing, offer valuable structural materials with enhanced coupling forces between the components. The applied polymer chemistry of such composites shows several common features with that of radiation grafting, e.g. the polymerization rate of oligomer-monomer mixtures in wood remains in most cases proportional to the square-root of the initiating dose-rate, just as in the simultaneous grafting, demonstrating that the chain termination kinetics remain regularly bimolecular in the corresponding dose-rate ranges. In the processing experiences of such composites, low dose requirement, easy process-control, and good technical feasibility have been found for composites of wood with oligomer-monomer mixtures, for coconut fibres with unsaturated polyesters and for pretreated wood fibre ...
Since several years we apply the radiation-grafting technique to prepare polymeric membranes for application in polymer electrolyte fuel cells (PEFCs). Our investigations presented here focus on changes in toughness of these materials after the various synthesis steps and the importance of membrane toughness for their application in PEFCs. (author) 2 figs., 4 refs.
French ... Title Synthese d'agregats metalliques par radiolyse de solutions aqueuses de sels simples ou complexes. Etude par M. E. du greffage des agregats sur membranes de carbone.
Previous investigations have shown that both the early biological response and the mechanical properties of a porous hydroxyapatite bone graft substitute are highly sensitive to its pore structure. The objective of this study was to evaluate whether the pore structure continued to influence bone integration in the medium to long term. Two screened batches of porous hydroxyapatite (PHA) designated as batch A and batch B, with porosities of approximately 60 and 80%, respectively, were selected for this study and implanted for periods of 5, 13, and 26 weeks into the lower femur of New Zealand White rabbits. Histomorphometric analysis of the absolute volume of bone ingrowth within batch A and B implants from 5 to 26 weeks showed that the absolute volume of bone ingrowth was consistently lower in batch A (10-21%), compared to batch B implants (24-31%). However, when the volume of bone ingrowth was normalised for the available pore space, this difference was reduced ...
Summary20 years ago, in 1987, Edelson and co-workers published their first report on the effectiveness of a new procedure, called extracorporeal photochemotherapy (ECP), in patients...Full Text Available
The safety of tissue allografts has come under increased scrutiny due to recent reports of allograft-associated bacterial and viral infections in tissue recipients. We report that 50 kGy of gamma irradiation, nearly three times the dose currently used, is an effective pathogen inactivation method when used under optimized conditions that minimize damage to the tissue. Cancellous bone dowels treated with a radioprotectant solution and 50 kGy of optimized irradiation had an ultimate compressive strength and modulus of elasticity equal to conventionally irradiated (18 kGy) and non-irradiated control bone grafts. We subjected bone dowels treated with this pathogen inactivation method to an in vitro cytotoxicity test using three different mammalian cell lines and concluded that the treated grafts were not cytotoxic. The log reduction of nine pathogens spiked into radioprotectant-treated bone irradiated to 50 kGy was also tested. We achieved 4.9 logs ...
Recent advances in cell culture technology permit the generation of large stratified epithelial sheets appropriate for wound coverage. Autografts (sheets prepared from the patient's own skin) have proven life-saving in the treatment of large third-degree burns and have been successfully employed in the management of chronic ulcers. Allografts (sheets prepared from the skin of an unrelated donor) have also been used. In our experience, cultured allografts derived from neonatal foreskin provide a potent stimulus to healing in a variety of partial thickness wounds. Their application is a simple outpatient procedure which involves no discomfort for the patient. In contrast to autografting, no biopsy is necessary and use of cultured allogenic cells permits immediate grafts availability and possibility of stockpiling and preserving grafts for future use. Preparation of epithelial sheets suitable for grafting is also faster and ...
The effects of lead on the development of the nervous system are of immediate concern to human health. While it is clear that lead can affect neuronal development at levels of exposure within the range found in the environment, the particular mechanism of the disruption is not readily ascertained. The goal of the authors research is to develop a model system in which the effects of lead on central nervous system development can be demonstrated. To study neuronal development in a system that minimizes such difficulties, the authors have grafted discrete brain regions derived from rat fetuses into the anterior chamber of the eye of adult hosts. The brain pieces continue organotypic development in the eye, but are isolated from possible secondary changes due to alterations in the development of the endocrine and other somatic systems because the adult host has these systems already fully developed. Using this system, they have discovered that lead induces a ...
Bulk monomer MMA was impregnated into simul, a fuel wood of Bangladesh, under vacuum and under normal temperature and pressure conditions in order to compare the mode of impregnation and its effect on various characteristic parameters of wood plastic composites. Methanol (MeOH) was used as the swelling solvent with methylmethacrylate (MMA) at MMA: MeOH = 70:30, v/v. Impregnation of the bulk monomer was very high under vacuum compared to that at normal condition; but the difference of grafting of MMA to the wood cellulose under these two impregnating conditions was much lower as compared to that of the uptakes of impregnating solution MMA + MeOH under these two modes of impregnation. Incorporation of additives to MMA + MeOH has substantially enhanced grafting, tensile strength, bending strength and compression strength of the composite to such an extent that there is virtually very little difference between vacuum impregnation and normal ...
In this paper, we prepared a novel cationic self-assembled micelle from poly(epsilon-caprolactone)-poly(ethyl glycol)-poly(epsilon-caprolactone) grafted polyethyleneimine (PCEC-g-PEI). The PCEC-g-PEI micelles, formed by self-assembly method, had mean particle size of ca. 82 nm and zeta potential of +22.5 mV at 37 degrees C, and could efficiently transfer pGFP into HEK293 cells in vitro. Meanwhile, as a model hydrophobic chemotherapeutic drug, honokiol was loaded into PCEC-g-PEI micelles by direct dissolution method assisted by ultrasonication. The honokiol loaded cationic PCEC-g-PEI micelles could effectively adsorb DNA onto its surface, while it could release honokiol in an extended period in vitro. This study demonstrated a novel DNA and hydrophobic chemotherapeutic drug co-delivery system. PMID:21121283
One of the greatest opportunities for using of biomass as a precursor in the production of polymeric materials is the lignocellulose composites that can combine high performance with low costs. This work is a initial study on the production of a lignocellulose reinforced polyethylene composite. A compatibilization made by a induced gamma radiation grafting reaction was used to increase the adhesion between the matrix and the reinforced or filled fibers. The lignocellulose materials were exposed to gamma radiation in order to promote a molecular degradation and increase its reactivity. The polymer, the lignocellulose material and the compatibilization were processed by extrusion and the composite produced by this process were characterized by mechanical tests. (author)
Lung transplantation has become an accepted option for many patients with end-stage pulmonary diseases. Anesthesia and surgery following lung transplantation may be required for various diseases that may affect both systemic organs and the transplanted graft. When a patient with a lung transplant undergoes surgery, there is the potential for interference with lung function, depending on the type of intervention and its anatomical site. Accurate preoperative evaluation, an understanding of the physiology of the transplanted lung, proper airway instrumentation, individualized management of intraoperative ventilation, and fluid balance are essential for a positive perioperative outcome.
Pipeline automated ultrasonic testing (AUT) uses fully automated equipment that travels around a pipe on a welding band in a linear scan to allow array pulses to provide ultrasound information on weld zones. Pipeline AUT is also used for zone discrimination as well as with special calibration blocks, dual gate output displays, and rapid defect sizing. AUT allows for the inspection of welds soon after completion, and can save construction costs by process control when combined with engineering critical assessment (ECA) to minimize rejection rates. Ultrasonic phased arrays (UPA) use an array of elements that are all individually wired, pulsed, and time-shifted. Elements are pulsed in groups of approximately 16 elements at a time for pipeline welds. Phased arrays can be used to combine electronic scanning, sectorial scanning and precision focusing to give a practical combination of displays. Optimum angles can be selected for welds and other components, and the electronic scanning ...
The treatment of bony, osteochondral, and ligamentous injuries of the tibio-talar requires precise preoperative planning by radiological investigation. This is essential to a correct understanding of the underlying pathology and will allow a proper classification of the injury, which is the basis of treatment. Conventional radiography using anteroposterior and lateral X-rays with comparative views of the noninjured side and, if necessary, rotated spot views and tomography are of high value especially in osteochondral fractures of the talus. Intraoperative control images in both planes after osteosynthesis are mandatory. For evaluation of the postoperative course and severity of arthrosis formation, the classification system of Bargon has proved its worth. In addition, tomography of the tibio-talar joint in two planes is useful especially in tibial pilon fractures, some malleolar fractures, and peripheral talar fractures. In talar fracture dislocations with concomitant compartment ...
The aim of the paper is to review the role of interventional radiology in the management of hemodialysis vascular access and complications in renal transplantation. The evaluation of patients with hemodialysis vascular access is complex. It includes the radiology/ultrasound (US) evaluation of the peripheral veins of the upper extremities with venous mapping and the evaluation of the central vein prior to the access placement and radiological detection and treatment of the stenosis and thrombosis in misfunctional dialysis fistulas. Preoperative screening enables the identification of a suitable vessel to create a hemodynamically-sound dialysis fistula. Clinical and radiological detection of the hemodynamically significant stenosis or occlusion demands fistulography and endovascular treatment. Endovascular prophylactic dilatation of stenosis greater than 50% with associated clinical abnormalities such as flow-rate reduction is warranted to prolong access patency. The technical success ...
This study investigated the feasibility of using a new adsorbent prepared from coconut coir pith, CP (a coir industry-based lignocellulosic residue), for the removal of uranium [U(VI)] from aqueous solutions. The adsorbent (PGCP-COOH) having a carboxylate functional group at the chain end was synthesized by grafting poly(hydroxyethylmethacrylate) onto CP using potassium peroxydisulphate-sodium thiosulphite as a redox initiator and in the presence of N,N'-methylenebisacrylamide as a crosslinking agent. IR spectroscopy results confirm the graft copolymer formation and carboxylate functionalization. XRD studies confirm the decrease of crystallinity in PGCP-COOH compared to CP, and it favors the protrusion of the functional group into the aqueous medium. The thermal stability of the samples was studied using thermogravimetry (TG). Surface charge density of the samples as a function of pH was determined using potentiometric titration. The ability of ...
Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver variability were 10.5 and ...
This study evaluated surface characteristics and overlaying properties of wood plastic composite (WPC) panels made from dry-blended rubber wood fiber-polypropylene (PP) powder formulations using a conventional flat-press process under laboratory conditions. Three levels of rubberwood fibers (Hevea brasiliensis), 40%, 50%, and 60%, based on the composition by weight, were mixed with the PP powder without and with 3% (based on weight) maleic anhydride grafted PP (MAPP) as a coupling agent. Contact angle measurements on the WPC samples were performed using a goniometer connected with a digital camera which collected one image per second. Roughness measurements, average roughness (R a), mean peak-to-valley height (R z), and maximum roughness (R y), were taken from the sanded samples along and ...
Summary: The surface coverage of amorphous silica gels used in the synthesis of silica polyamine composites has been investigated by 29Si NMR. By diluting the polyamine anchor silane, chloropropyl trichlorosilane, with methyl trichlorosilane it was found that surface coverage could be markedly improved for a range of amine polymers after grafting to the silica surface. The commensurate decrease in the number of anchor points and increase in the number of free amines results in an increase in metal capacity and/or an improvement in capture kinetics. Solid state CPMAS-13C NMR has been employed to investigate the structure and metal ion binding of a series of these composite materials. It is reported that the highly branched polymer, poly(ethyleneimine) (PEI) exhibits much broader 13C NMR res...
Much progress has been made in the clinical, biological and technical aspects of the T-cell-depleted haploidentical hematopoietic stem cell transplantation (HSCT). Our experience demonstrates that infusing a megadose of extensively T-cell-depleted hematopoietic peripheral blood stem cells after an immuno-myeloablative conditioning regimen in acute leukemia patients ensures sustained engraftment with minimal GvHD without the need of any post-transplant immunosuppressive treatment. Since our first successful pilot study, our efforts have concentrated on developing new conditioning regimens, optimizing the graft processing and improving the post-transplant immunological recovery. The results we have so far achieved in high risk acute leukemia patients show that haploidentical transplantation ...
Abstract Poly(butylene terephthalate) (PBT) composites containing multiwalled carbon nanotubes (MWCNTs) were prepared using a melt-blending process and used to examine the effects on the composite structure and properties of replacing PBT with acrylic acid-grafted PBT (PBT-g-AA). PBT-g-AA and multihydroxyl-functionalized MWCNTs (MWCNTs-OH) were used to improve the compatibility and dispersibility of the MWCNTs within the PBT matrix. The composites were characterized morphologically using transmission electron microscopy, and chemically using Fourier transform infrared, solid-state 13C NMR and UV-visible absorption spectroscopy. The antibacterial and electrical conductivity properties of the composites were also evaluated. MWCNTs or MWCNTs-OH enhanced the antibacterial activity and electric...
Allogeneic stem-cell transplantation (SCT) is potentially curative therapy in AML by providing both dose-intensive chemo-radiotherapy and induction of graft-versus-leukemia (GvL) effect. Historically, more emphasis was given to the intensity of conditioning. Over the last decade the pendulum turned more towards induction of GvL as the primary goal. A plethora of non-myeloablative (NMA) and reduced-intensity conditioning regimens (RIC) were introduced trying to reduce transplant-related toxicities and allow SCT in elderly and medically infirm patients. In addition, reduced-toxicity myeloablative regimens (RTC) based on fludarabine and myeloablative alkylating-agent doses were designed to allow safer administration of dose-intensive therapy. Conditioning dose-intensity is highly correlated w...
The treatment of acetabular bone defects presents a great challenge in revision total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiological outcome of revision THA using jumbo cups for acetabular reconstruction after applying the bone-grafting technique. We studied 17?patients with acetabular defects ranging from Type 2A to Type 3A according to Paprosky`s classification. According to the AAOS-score twelve patients were classified as Type II and five patients as Type III. Uncemented press-fit cups with an outer diameter larger than 64?mm were used in all cases. Fifteen patients received morselized bone allografts. In eight patients an additional screw fixation was necessary. The mean follow-up period was 82?months (range 33?149). The mean Harris Hip...
Considerable interest has focused recently on the use of lignocellulosic fibers as a reinforcement for thermoplastic polymers. The combination of these dissimilar materials, however, is characterized by a widespread incompatibility that leads to a weak fiber/polymer interface and poor performance properties for the composite. In an effort to improve compatibility a number of fiber surface modification approaches have been investigated including plasma, ozone, and polymer grafting treatments. Evaluation of adhesion improvements has been complicated by processing variables that are difficult to control. This paper will discuss the use of the-micro-debond test in quantifying the interfacial shear strength (ISS) in wood fiber/polystyrene composites. Wood fibers were modified to different degrees with styrene-maleic anhydride copolymers that varied in their composition. The effect of fiber modification on surface energetics was determined using dynamic contact angle ...
In several vertebrate classes, the M?ller glia are capable of de-differentiating, proliferating, and acquiring a progenitor-like state in response to acute retinal injury or in response to exogenous growth factors. Our previous study has shown that M?ller cells can be activated and de-differentiated into retinal progenitors during Royal College of Surgeons (RCS) rats' degeneration, although the limited proliferation cannot maintain retinal function. We now report that rat retinal stem cells (rSCs) transplanted into RCS rats slowed the progression of retinal morphological degeneration and prevented the functional disruption. Further, we found that retinal progenitor cells labeled with Chx10 were increased significantly after rSCs transplantation, and most of them are mainly from activated M...
A new stem cell-scaffold construct based on poly-l-lactide (PLLA) nanofibers grafted with collagen (PLLA-COL) and cord blood-derived unrestricted somatic stem cells (USSC) were proposed to hold promising characteristics for bone tissue engineering. Fabricated nanofibers were characterized using SEM, ATR-FTIR, tensile and contact angle measurements. The capacity of PLLA, plasma-treated PLLA (PLLA-pl) and PLLA-COL scaffolds to support proliferation and osteogenic differentiation of USSC was evaluated using MTT assay and common osteogenic markers such as alkaline phosphatase (ALP) activity, calcium mineral deposition and bone-related genes. All three scaffolds showed nanofibrous and porous structure with suitable physical characteristics. Higher proliferation and viability of USSC was observe...
Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).
Upconversion nanoparticles (UCNPs) with unique multi-photon excitation photoluminescence properties have recently been intensively explored as novel contrast agents for low-backgroundbiomedical imaging. In this work, we functionalize UCNPs with a polyethylene glycol (PEG) grafted amphiphilic polymer. The PEGylated UCNPs are loaded with a commonly used chemotherapy molecule, doxorubicin (DOX), by simple physical adsorption via a supramolecular chemistry approach for intracellular drug delivery. The loading and releasing of DOX from UCNPs are controlled by varying pH, with an increased drug dissociation rate in acidic environment, favorable for controlled drug release. Upconversion luminescence (UCL) imaging by a modified laser scanning confocal microscope reveals the time course of intracel...
Nonfunctioning pancreatic endocrine tumors (PETs) are rare and generally asymptomatic. A 68-year-old woman who had refused treatment for a pancreatic mass, revealed by ultrasonography to be 55 mm in diameter, was referred to us again 29 months later with jaundice. Investigations showed an 82-mm tumor in the head of pancreas, exposed from the papilla of Vater to the duodenal lumen. After biliary decompression and drainage, we performed pancreatoduodenectomy with resection of the portal vein and superior mesenteric vein, followed by reconstruction using a cylindrically customized autologous graft harvested from the right ovarian vein. The tumor was resected curatively. Microscopically, it consisted of trabecular and ribbon-like arrangement of neoplastic cells. Immunohistochemical staining wa...
Fifty-nine patients underwent free flap osteocutaneous reconstruction that consisted of flaps of the dorsum of the foot in 26 patients and iliac crest flaps in 33 with a success rate of 92 percent and a mortality rate of 1.6 percent. These flaps, which require the expertise of microvascular surgeons, are time-consuming and complicate operating room and time management, but they represent a remarkable advance in reconstruction that can facilitate cosmetic and functional recovery of the patient. In particular, they promote healing in radiation-recurrent oral cancer and represent a definitive form of management for established radionecrosis of the mandible. The large volume of tissue available with iliac crest osteocutaneous grafts permits the management of patients with extensive cancer involving the skin, mucosa, and bone, but cancer control may still be disappointing and there is a need for improved adjuvant chemotherapy protocols. This technique appears to be a ...
The grafted human glioblastoma cell CB109 was used as a model for intralesional therapy with 131I-labelled hyaluronectin glycoprotein (131I-HN). 131I-HN bound specifically to in situ hyaluronic acid (HA), a main component of the extracellular matrix which is involved in tumour invasion. Labelling experimental conditions were determined and, finally, 25 {mu}Ci/{mu}gHN, 1 {mu}g chloramine-T/{mu}gHN and a 60-s stirring period provided a 131I-HN preparation with an optimal affinity for HA (64% compared to unlabelled HN). Following intratumoral injection, 131I-HN was retained with a limited diffusion outside the tumour. On day 4 the radioactivity concentrated in the tumour was still 25 times greater than that in the liver, spleen and kidneys combined. For therapeutic assays, 65 {mu}Ci 131I-HN was injected into the tumour, resulting in a delivery of 6.8 Gy over a 7-day period. Controls received unlabelled HN, heat-inactivated HN, a mixture of inactivated HN plus free ...
Silanization of the silica gel surface in the synthesis of silica gel polyamine composites uses (chloropropyl)-trichlorosilane (CPTCS). It is possible to substitute a molar fraction of reagent CPTCS with methyltrichlorosilane (MTCS), creating a mixed silane surface layer. Two types of silica gels were modified with a series of MTCS:CPTCS molar ratios. Solid-state CP/MAS 29Si and 13C NMR spectroscopies were used to evaluate the surface silane composition. Surface silane coverage was markedly improved for the resulting gels. When polyamines were grafted to the resultant MTCS:CPTCS silane layers, it was shown that the decrease in the number of propyl attachments to the polyamine resulted in increased quantities of ''free amines''. Optimum MTCS:CPTCS ratios were determined for three polyamines grafted onto one silica gel. A substantial free amine increase was observed for poly(allylamine) (PAA). Metal uptake ...
Silanization of the silica gel surface in the synthesis of silica gel polyamine composites uses (chloropropyl)-trichlorosilane (CPTCS). It is possible to substitute a molar fraction of reagent CPTCS with methyltrichlorosilane (MTCS), creating a mixed silane surface layer. Two types of silica gels were modified with a series of MTCS:CPTCS molar ratios. Solid-state CP/MAS 29Si and 13C NMR spectroscopies were used to evaluate the surface silane composition. Surface silane coverage was markedly improved for the resulting gels. When polyamines were grafted to the resultant MTCS:CPTCS silane layers, it was shown that the decrease in the number of propyl attachments to the polyamine resulted in increased quantities of ''free amines''. Optimum MTCS:CPTCS ratios were determined for three polyamines grafted onto one silica gel. A substantial free amine increase was observed for poly(allylamine) (PAA). Metal uptake ...
A mesoscopically ordered lamellar gel phase of a polymer-grafted, lipid-based complex fluid is used as a scaffolding to spatially organize inorganic nanoparticles. The complex fluid provides both a highly anisotropic environment and a segregated aqueous and organic domains in which inorganic nanoparticles can be selectively placed by tailoring their size and surface characteristics. Three types of silver nanoparticles -- underivatized, surfactant-stabilized, and dodecanthiol-derivatized -- were evaluated. Comparison of the surface plasmon resonance of the various silver particles dispersed in conventional solvents to those contained within the complex fluid was used to determine the region of spatial localization in the lamellar gel phase. Silver particles rendered hydrophobic by capping with an alkane thiol insert into the hydrocarbon bilayer region. Surfactant-stabilized and underivatized silver nanoparticles reside in the aqueous channels, with the latter ...
The aim of this study was to compare the results of different treatment strategies for osteochondral defects (OCD) of the talus. Electronic databases from 1966 to June 2000 were systematically screened. Thirty-nine studies fulfilled our inclusion criteria. No randomized clinical trials could be identified. The results of nonoperative treatment were described in 14 studies, of excision alone in 4, of excision and curettage in 10, of excision, curettage and drilling in 21, of cancellous bone grafting in 2, of fixation in 3, and of osteochondral transplantation in 1. Good or excellent results were found in 45% of the cases. Comparison of different surgical procedures showed that excision, curettage and drilling resulted in the highest mean success rate (86%), followed by excision and curettage (76%) and excision alone (38%). From the results of this systematic review we conclude that nonoperative treatment and excision alone are not to be recommended for treatment of ...
Recently, various types of allogeneic skin substitutes including cultured epidermal substitute (CES), cultured dermal substitute (CDS), and cultured skin substitute (CSS), which are composed of keratinocytes and/or fibroblasts as the cellular component(s), have been used as biological wound dressings. In our study, the allogeneic CDS was prepared by plating fibroblasts on a spongy collagen. The clinical evaluation was conducted using fresh or cryopreserved allogeneic CDS. In 145 of our clinical cases, 95% (138/145) of various wounds were evaluated as achieving good or excellent results, including 96% (22/23) of deep dermal burns (DDB) and dermal burns (DB), 100% (53/53) of partial-thickness donor wounds, 91% (21/23) of traumatic skin defects, 100% (5/5) of pressure ulcers, 82% (9/11) of chronic skin ulcers, 100% (6/6) of coverage for debrided DB, and 92% (22/24) of coverage for autologous meshed graft. The results obtained in our study suggest that the allogeneic ...
A series of silylated Co/SBA-15 catalysts were prepared via the reaction of surface Si-OH of SBA-15 with hexamethyldisilazane (HMDS) under anhydrous, vapor-phase conditions, and then characterized by FT-IR, N2 physisorption, TG, XRD, and TPR-MS. The results showed that organic modification led to a silylated SBA-15 surface composed of stable hydrophobic Si-(CH3)3 species even after calcinations and H2 reduction at 673 K. Furthermore, the hydrophobic surface strongly influenced both metal dispersion and reducibility. Compared with non-silylated Co/SBA, Co/S-SBA (impregnation after silylation) showed a high activity, due to the better cobalt reducibility on the hydrophobic support. However, S-Co/SBA (silylation after impregnation) had the lowest FT activity among all the catalysts, due to the lower cobalt reducibility along with the steric hindrance of grafted -Si(CH3)3 for the re-adsorption of ?-olefins. -- Graphical abstract: The silylation of an SBA-15 before ...
The surface coverage of amorphous silica gels used in the synthesis of silica polyamine composites has been investigated by 29Si NMR. By diluting the polyamine anchor silane, chloropropyl trichlorosilane, with methyl trichlorosilane it was found that surface coverage could be markedly improved for a range of amine polymers after grafting to the silica surface. The commensurate decrease in the number of anchor points and increase in the number of free amines results in an increase in metal capacity and/or an improvement in capture kinetics. Solid state CPMAS-13C NMR has been employed to investigate the structure and metal ion binding of a series of these composite materials. It is reported that the highly branched polymer, poly(ethyleneimine) (PEI) exhibits much broader 13C NMR resonances than the linear polymers poly(allylamine) (PAA) and poly(vinylamine) (PVA). These results are understood in terms of the low energy conformations calculated from molecular modeling ...
recycling of waste polypropylene (WPP) and waste rubber (WR) originated from rejected worn-out tires present very important problem due to their huge amount and their negative impact on environment. many communities in the world are struggling with this problem of how to manage waste disposal, in order to eliminate or reduce waste rubber from the environment and to reduce costs of some rubber and polypropylene articles. trials to reuse waste rubber and waste polypropylene, have encountered some difficulties.such two substrate polymers differ from each other in nature, since waste polypropylene is thermoplastic while waste rubber exists in thermosetting state. accordingly, the study and use of their mixtures should be very interesting.the aim of this work is to modify the physical and chemical properties of WR and WPP each in the form of powder (120,80 mech size), through a trial to graft some vinyl comonomers onto their surfaces using gamma radiation
Severe damage to the pelvic viscera is a complication of irradiation therapy that, unfortunately, cannot always be avoided. Resulting rectal and rectocolonic strictures, rectovaginal fistulas, and shortening and stenosis of the vagina present very difficult problems that frequently require a colostomy for relief and may permanently impair sexual function. The authors present a new approach to correction of these unfortunate lesions based on the use of proximal nonirradiated colon which serves as a vascular pedicle graft to correct the defect without a complicated and massive resection. Twenty-two such operations have been done with 19 satisfactory to excellent results and two total failures (one death from small bowel complications). All patterns and combinations of irradiation injury have been found amenable to this technique of repair. These have included both web and linear strictures with and without fistulas. In half of the patients, it was possible to make ...
Wood sawdust has been applied to manufacture the sawdust-clay-plastic composite (SDCPC) by radiation process for the purpose of disposing large amount of wood sawdust waste material. The process comprises the impregnation of liquid vinyl monomers into the completely dried molded sawdust-clay specimens followed by exposure to Co-60 gamma-radiation to induce graft-copolymerization of the impregnated vinyl monomers onto the sawdust-clay matrix. The comonomer system of unsaturated polyester and vinyl compounds was found to be the ideal impregnating monomer for the preparation of the SDCPC from the viewpoint of the technological and economical advantages. The SDCPC material has a variety of the sawdust content which enables the composite to have wide range of mechanical properties, e.g., 410 to 1100 kg/cm/sup 2/ in compressive strength, 120 to 380 kg/cm/sup 2/ in tensile strength and 0.32 to 4.41 kg/mm/sup 2/ in static bending strength. The SDCPC having higher content ...
Financial DisclosurePhacoemulsification and implantation of a hydrophilic acrylic toric intraocular lens (IOL) (T-flex 623T) with customized cylindrical power was performed in 1 eye in 3 consecutive patients with cataract and high postkeratoplasty astigmatism (range 6.75 to 8.75 diopters [D]). Twelve months postoperatively, the uncorrected distance visual acuity improved from 20/200 to 20/30 in Case 1, from 20/400 to 20/40 in Case 2, and from 20/200 to 20/25 in Case 3 and the corrected distance visual acuity was 20/25 or better in all 3 eyes. The spheroequivalent was within +-0.50 D of the intended value and the refractive astigmatism was less than 1.00 D. The corneal grafts were transparent, and the endothelial cell loss range was 6% to 12%. Rotation of the toric IOL was less than 5 degre...
To compare clinical effectiveness of Viabil-covered stents versus uncovered metallic Wallstents, for palliation of malignant jaundice due to extrahepatic cholangiocarcinoma, 60 patients were enrolled in a prospective and randomized study. In half of the patients a bare Wallstent was used, and in the other half a Viabil biliary stent. Patients were followed up until death. Primary patency, survival, complication rates, and mean cost were calculated in both groups. Stent dysfunction occurred in 9 (30%) patients in the bare stent group after a mean period of 133.1 days and in 4 (13.3%) patients in the covered stent group after a mean of 179.5 days. The incidence of stent dysfunction was significantly lower in the covered stent group (P = 0.046). Tumor ingrowth occurred exclusively in the bare stent group (P = 0.007). Median survival was 180.5 days for the Wallstent and 243.5 days for the Viabil group (P = 0.039). Complications and mean cost were similar in the two groups. Viabil ...
Infrainguinal peripheral occlusive disease is increasingly being treated by endovascular techniques. Bare metal stainless steel, self-expanding nitinol stents, drug-eluting and covered stents (stent grafts) are becoming increasingly more important adjuncts to percutaneous translumninal angioplasty in the treatment of peripheral artery disease. In this article the available evidence supporting the use of stents in the femoropopliteal and tibial arteries will be described as well as their limitations. Future stent developments will also be discussed. (orig.) [German] Die endovaskulaere Therapie spielt bei der Therapie der peripheren arteriellen Verschlusskrankheit (PAVK) eine wichtige Rolle. Unbeschichtete ballonexpandierbare Stahlstents, selbstexpandierende Nitinolstents sowie medikamentenbeschichtete und ''covered stents'' (Stentgrafts) haben eine zunehmende Bedeutung als Zusatztherapie zusammen mit der primaeren ...
Polysaccharides like cellulose and chitosan are known for their filmic properties. This paper concerns the synthesis and the study of chitosan-based polymer electrolytes. A preliminary work concerns the study of glucosamine reactivity. The poly-condensation of chitosan ethers (obtained by reaction with ethylene oxide or propylene oxide) with bifunctional and monofunctional oligo-ethers leads to the formation of thin lattices (10 {mu}m) having excellent mechanical properties. The presence of grafted polyether chains along the polysaccharide skeleton allows to modify the vitreous transition temperature and the molecular disorder of the system. Two type of polymer electrolytes have been synthesized: electrolytes carrying a dissolved alkaline metal salt and ionomers. The analysis of their thermal, dynamical mechanical, nuclear magnetic relaxation, electrical, and electrochemical properties shows that this new class of polymer electrolytes has the same performances as ...
Percutaneous coronary revascularisation [PCR] improves angina and health related quality of life [HRQOL] compared to standard medical therapy. It is unknown whether PCR has the same benefits for patients with a history of CABG. Over a period of 5?years, we assessed HRQOL of patients undergoing PCR using Part 1 of the Nottingham Health Profile [NHP] at baseline 3, 12 and 24?months. We compared HRQOL after PCR in 255 patients with CABG to 2680 without. There were more males [81.1% v 69.6% p?=?0.002] and older patients [mean age 60.1?years v. 58.0 p?=?0.03] in CABG group. Perceived HRQOL improved at 24?months for pain, energy and emotional reaction but the improvement was less in the CABG group. However, mean NHP scores at 24?months for those with CABG had returned to baseline levels for slee...
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise information about the spinal posterior osteophytes ...
The use of cathode ray irradiated arterial allografts on the reconstruction of small peripheral arteries is described. The fate of irradiated arterial allografts implanted subcutaneously in rats was compared histologically with that of allografts which were fresh, frozen or stored in 70% alcohol. Follow-up studies were made of 10 dogs in which irradiated arterial allografts had been implanted in the femoral artery to be evaluated; long term patency by arteriography, gross and histologic changes of the implanted allografts, and the luminal surface of the implanted allografts by scanning electron microscopic studies. For the purpose of antigenic studies, extracts of canine arteries which had been irradiated, frozen or stored in 70% alcohol, were prepared and tested by the following immunological methods: precipitation, Ouchterlony gel diffusion, and passive cutaneous anaphylaxis. From the results obtained in these experiments, it was concluded that, compared with fresh or frozen ...
To evaluate the effectiveness of percutaneous transluminal angioplasty(PTA) and to determine the factors affecting the long-term patency rate in the management of insufficient hemodialytic arteriovenous fistula(AVF). Forty-nine cases of insufficient hemodialytic AVF were treated in 44 patients(native AVF:20, graft AVF:29, M:17, F:27, Age:22-70 years). In 28 thrombus patients, thrombolysis was performed with urokinase, and was followed by PTA. The initial success rate and complications of PTA were evaluated. According to the site and length of the stenosis, type and age of the AVF, the presence or abscence of thrombus, a history of diabetic mellitus, the patient's age, and the duration of renal failure, patency rates were compared within each subgroup using the Kaplan-Meier logrank test. The initial success rate of PTA for insufficient hemodialytic AVF was 88%(43/49), the patency rate of PTA was 67% at 6 months, and 50% at 12 months. The initial success ...
2-hydroxyethyl methacrylate (HEMA) has been deposited onto the surface of silicon substrate (thickness = 500 ?m) using plasma polymerization technique. Polymerization process was carried out in an in-house developed inductively coupled plasma polymerization setup. The depositions were carried out using RF power supply (13.56 MHz) at power of 75 W for 10 and 40 min. The RF supply was coupled to the inductance through a matching network. The effect of plasma polymerization (surface grafting) on the degree of surface modification has been investigated. The chemical changes on the polymer backbone are followed from the results of Fourier transform infrared (FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS), which show the peaks corresponding to the functional groups of the HEMA polymerized onto the silicon surface. The morphology of the modified surfaces has also been investigated using scanning electron microscopy (SEM) and atomic force microscopy (AFM). ...
Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7#+-# 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 prosthetic graft ...
Most of the tissue banks in the Asia Pacific region have been using ionising radiation at 25 kGy to sterilise human tissues for save clinical usage. Under tissue banking quality system, any dose employed for sterilisation has to be validated and the validation exercise has to be a part of quality document. Tissue grafts, unlike medical items, are not produced in large number per each processing batch and tissues relatively have a different microbial population. A Code of Practice established by the International Atomic Energy Agency (IAEA) in 2004 offers several validation methods using smaller number of samples compared to ISO 11137 (1995), which is meant for medical products. The methods emphasise on bioburden determination, followed by sterility test on samples after they were exposed to verification dose for attaining of sterility assurance level (SAL) of 10{sup -1}. This paper describes our experience in using the IAEA Code of Practice in conducting the ...
Comprehensive investigation has been made into the application of the polymerization hardening by radiation, particularly electron beam, to the composites of polymers and other materials. The report is divided into four parts, namely 1) characteristics and problems of the reaction of curing by radiation polymerization, 2) improvement of the bonding capability of high molecular weight materials, 3) bonding by radiation, and 4) composites made by the impregnation and polymerization hardening of monomers. The first part includes the effects of dose rate, temperature rise during the hardening, the peculiarity of electron beam irradiation at high dose rate, reaction environment and additive effects. Main conclusions are as follows: caution must be taken to the amount of residual double bonds because they affect the quality of hardened polymers; the polymerization hardening reaction at high dose rate cannot be analogized by that at low dose rate; and the presence of the inhibitors of radical ...
The spontaneous ionic polymerization of 4-vinyl-pyridine in presence of mono-tosylated or bromated short chains of poly(ethylene oxide)-(PEO) is used to prepare amorphous comb-like poly-cations with low Tg. The polymer electrolyte properties of these new structures have been studied without any addition of salts. The ionic conductivity of these fixed cation poly-electrolytes depends on the length of the grafted PEO and varies from 10{sup -7} to 10{sup -4} S/cm between 25 and 80 deg. C. It is only weakly dependent on the nature of the cation but it is controlled by the movements of the pyridinium cation which are facilitated by the plastifying effect of the POE chains which do not directly participate to the ionic transport. (J.S.) 17 refs.
Better understanding and modelling of three-phase flow through porous media is of great interest, especially for improved oil recovery methods such as gas injection processes. Early theoretical and experimental studies have already demonstrated that the wettability characteristics of the solid surface and the spreading characteristics of the fluid system hold the key roles. This observation is confirmed by our theoretical results using DLP theory on the stability and the thickness of static oil films. In most of the works related to three-phase flow processes, homogeneous wettability is assumed. There exist only a few studies demonstrating the tremendous impact of the wettability heterogeneities on gas injection. The objective of the present work is twofold: to demonstrate the effect of small scale wettability heterogeneities on gas injection efficiency, and to develop a tool to predict this impact for various patterns and spatial distributions. To this end an experimental ...
A semiquantitative assay was developed and used to measure the effects of immune responses against 16 independent non-H-2 antigenic loci on erythropoietic stem cells. The assay compares repopulation in genetically anemic WBB6F1-W/Wv recipients that have normal immune responses, and in lethally irradiated WBB6F1 +/+ mice whose immune responses are suppressed by the irradiation. The differences in repopulating ability between these two types of recipients measure how immune responses affect erythropoietic stem cells. Stem cell repopulating abilities for the cells with antigens specified by the Thy-1, H-1, H-24, Ly-1, H-37, and H-17 loci were affected slightly, if at all. Repopulating abilities were moderately reduced by responses against antigens specified by H-15, 16, Ea-2, and Ly-2, 3 loci, and against the differences between the B6 and B10 genotypes, although marrow of these types cured W/Wv recipients. A surprising result occurred for the antigen specified by the H-8 locus, in which ...
Mesenchymal stem cells (MSCs) are a potential source of smooth muscle cells (SMCs) for constructing tissue-engineered vascular grafts. However, the details of how specific combinations of vascular microenvironmental factors regulate MSCs are not well understood. Previous studies have suggested that both mechanical stimulation with uniaxial cyclic strain and chemical stimulation with transforming growth factor {beta}1 (TGF-{beta}1) can induce smooth muscle markers in MSCs. In this study, we investigated the combined effects of uniaxial cyclic strain and TGF-{beta}1 stimulation on MSCs. By using a proteomic analysis, we found differential regulation of several proteins and genes, such as the up-regulation of TGF-{beta}1-induced protein ig-h3 (BGH3) protein levels by TGF-{beta}1 and up-regulation of calponin 3 protein level by cyclic strain. At the gene expression level, BGH3 was induced by TGF-{beta}1, but calponin 3 was not significantly regulated by mechanical ...
To evaluate the success rates, long-term patency rates and factors affecting the patency rates of percutaneous transluminal angioplasty(PTA) and thrombolysis in the management of insufficient access during hemodialysis. Between January 1991 and March 1995, 37 insufficient shunts(23 native fistulae and 14 graft fistulae) were treated in 31 patients. PTA was performed in 24 shunts, and thrombolysis in 13;in seven of these latter, thrombolysois was followed by PTA. The success and long-term patency rates of PTA and thrombolysis were evaluated. Shunts were subdivided according to a patient's age, type and age of the shunt, and number and length of the stenosis, and the degree of residual stenosis and in each subgroup, patency rates was compared. The overall success rate of PTA and thrombolysis for insufficient hemodialytic access was 78.4%(29/37). The success rates of PTA and thrombolysis were 91.7%(22/24) and 53.8%(7/13), respectively. The patency rates of ...
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to ...
Sufficient genetic diversity exists in Indian tree species to give large genetic gains. Improvement potential, using wild gene resources for selection and breeding is vast as there are over 244 genera and 400 forest tree species in India. Of these over 30 species and 22 genera are of outstanding forestry value. Selective genetic-variation can be lifted from wild populations, multiplied vegetatively or by seed, and planted with controlled germplasm sources. Among the Indian species no less than 74 reproduce by cutting, 11 by layers, 9 by grafting and buding and 104 by root suckers. More than 161 species coppice vigorously. Afforestation techniques of over 170 species have been worked out. Tree genetic approach of survey of natural variability, quick evaluation, selection, conservation multiplication and planting superior variability directly in the field can give immediate genetic gains. This article discusses genetic information on indigenous species for use of ...
Autoreactive cytotoxic CD8 T-cells (CTLs) play a key pathogenic role in the destruction of insulin-producing beta-cells resulting in type 1 diabetes. However, knowledge regarding their targets is limited, restricting the ability to monitor the course of the disease and immune interventions. In a multi-step discovery process to identify novel CTL epitopes in human preproinsulin (PPI), PPI was digested with purified human proteasomes, and resulting COOH-fragments aligned with algorithm-predicted HLA-binding peptides to yield nine potential HLA-A1, -A2, -A3 or -B7-restricted candidates. An UV-exchange method allowed the generation of a repertoire of multimers including low-affinity HLA-binding peptides. These were labeled with quantum dot-fluorochromes and encoded in a combinatorial fashion, allowing parallel and sensitive detection of specific, low-avidity T-cells. Significantly increased frequencies of T-cells against four novel PPI epitopes (PPI(4-13)/B7, PPI(29-38)/A2, PPI(76-84)/A3 ...
We tested the hypothesis that insulin-dependent diabetic patients with coronary artery bypass graft surgery experience altered coupling of cerebral blood flow and oxygen consumption. In a study of 23 patients (11 diabetics and 12 age-matched controls), cerebral blood flow was measured using 133Xe clearance during nonpulsatile, alpha-stat blood gas managed cardiopulmonary bypass at the conditions of hypothermia and normothermia. In diabetic patients, the cerebral blood flow at 26.6 +/- 2.42 degrees C was 25.3 +/- 14.34 ml/100 g/min and at 36.9 +/- 0.58 degrees C it was 27.3 +/- 7.40 ml/100 g/min (p = NS). The control patients increased cerebral blood flow from 20.7 +/- 6.78 ml/100 g/min at 28.4 +/- 2.81 degrees C to 37.6 +/- 8.81 ml/100 g/min at 36.5 +/- 0.45 degrees C (p less than or equal to 0.005). The oxygen consumption was calculated from jugular bulb effluent and increased from hypothermic values of 0.52 +/- 0.20 ml/100 g/min in diabetics to 1.26 +/- 0.28 ...
Purpose: To evaluate the success rates of the implantation of stent grafts in the treatment of peripheral aneurysms. Materials and methods: in 13 patients with 15 aneurysms at the common iliac artery (n = 6), external iliac artery (n = 1), hypogastric artery (n = 2), femoral artery (n = 2) or popliteal artery (n = 4), implantation of dacron-covered nitinol stents was performed. The patients were followed up for three to 20 months (mean, 8.8 months) with intravenous digital subtraction angiography, CT or colour-coded Doppler sonography. Results: In all cases, the aneurysm was successfully occluded after stent implantation. In one case with a popliteal aneurysm, kinking of the vessel caused thrombosis of the stent. The stent was successfully reopened. The aneurysm however, had to be surgically treated 9 months later. The primary and secondary patency rates at 6 months were 93% and 100%, respectively. Conclusion: The method described might be an alternative therapy to ...
The purpose of this study was to determine the incidence of central vein stenosis and occlusion following upper extremity placement of peripherally inserted central venous catheters(PICCs) and venous ports. One hundred fifty-four patients who underwent venography of the ipsilateral central veins prior to initial and subsequent venous access device insertion were retrospectively identified. All follow-up venograms were interpreted at the time of catheter placement by one interventional radiologist over a 5-year period and compared to the findings on initial venography. For patients with central vein abnormalities, hospital and home infusion service records and radiology reports were reviewed to determine catheter dwelltime and potential alternative etiologies of central vein stenosis or occlusion. The effect of catheter caliber and dwell time on development of central vein abnormalities was evaluated. Venography performed prior to initial catheter placement showed that 150 patients had ...
Poly-Lactic-Acid (PLA) was evaluated for coating of vascular endoprotheses in the treatment of experimental arterio-venous-fistulae (AVF). Bilateral carotid-external jugular AVF were created in 5 adult dogs. 7 PLA coated nitinol stents were placed via a transfemoral approach covering 5 AVF. The contralateral AVF remained untreated. Angiography was performed immediately after stent placement, at weeks 1 and 3 and at months 3, 6 and 9. All grafts were removed and underwent histologic examination. In 2 cases the occlusion of the AVF was successful, while misplacement occurred in 3 cases. Occlusion of the parent vessel was disclosed in 3 cases. Histologic examination revealed a mild inflammatory reaction with the presence of macrophages. There was no foreign-body reaction or fragmentation of the arterial vessel wall. PLA, which is a well-known biodegradable material, showed a good mid-term biocompatibility. Elastic mismatch of the non-elastic coating and the ...