WorldWideScience
1

The Rab GTPase RabA4d Regulates Pollen Tube Tip Growth in Arabidopsis thaliana[W  

UK PubMed Central (United Kingdom)

During reproduction in flowering plants, pollen grains form a tube that grows in a polarized fashion through the female tissues to eventually fertilize the egg cell. These highly polarized pollen tubes...Full Text Available

2009-02-01

2

Mechanistic insights from a quantitative analysis of pollen tube guidance  

UK PubMed Central (United Kingdom)

BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available

3

Pollen flora of Pakistan--LXVII: acanthaceae  

International Nuclear Information System (INIS)

Pollen morphology of 30 species of the family Acanthaceae belonging to 11 genera has been investigated using light and scanning electron microscope. Acanthaceae is a eurypalynous family. Pollen are usually radially symmetrical, isopolar, sub-prolate to prolate rarely prolate-spheroidal or sub-oblate to oblate-spheroidal, generally tricolporate or heterocolporate rarely colpate or porate. Exine ornamentation varies from medium to coarse reticulate, or often lopho-reticulate with luminae perforated to baculate or scabrate. On the basis of apertural type, exine ornamentation and colpal membrane eight distinct pollen types have been recognized viz., Pollen type-I: Barleria cristata-type, Pollen type-II: Blepharis ciliaris-type, Pollen type-III: Hygrophila polysperma - type, Pollen type-IV: Justicia adhatoda-type, Pollen ...

2010-12-01

4

Effects of cryopreservation on germinability of olive (Olea europaea L.) pollen  

British Library Electronic Table of Contents (United Kingdom)

Long term storage of viable pollen is important for bank germplasm constitution to preserve resources that can be used in breeding programs, biotechnologies and genetic engineering. Pollen from 12 olive (Olea europaea L.) cultivars was stored for 1?year in liquid nitrogen at ?196?C. The morphology of pollen grains and germination rates on fresh and long term stored pollen were observed. Results on in vitro pollen germinability, both before and after cryopreservation, showed highly significant responses among the 12 cultivars. The relationship between germinability and pollen grain size did not reveal any significant relationships in both treatments. Our findings will contribute to the improvement of olive pollen preservation and lead to find a more efficient method for its long term storag...

2011-01-01

5

Corn pollen deposition on milkweeds in and near cornfields  

UK PubMed Central (United Kingdom)

The density of corn pollen on leaves of milkweed plants inside and outside of cornfields was measured in several studies from different localities. The purpose was to obtain a representative picture...Full Text Available

2001-10-09

6

Ancient Pollen Yields Insight into Forest Biodiversity  

Science.gov (United States)

... data on pollen from red maple, birch, beech, ash, oak, hemlock and elm trees isolated from cores of ...

9

Isolation and Characterization of a Novel Nuclear Protein from Pollen Mother Cells of Lily  

UK PubMed Central (United Kingdom)

Pollen mother cells of the lily (Lilium speciosum) were found to have a histone-H1-like protein (PMCP) not detected in other tissues. The PMCP appears from the late S-G2...Full Text Available

1990-11-01

10

Alexandria's Eastern Harbor, Egypt: Pollen, Microscopic Charcoal, and the Transition from Natural to Human-Modified ...  

Science.gov (United States)

... doi: 10.2112/JCOASTRES-D-09-00089.1 Alexandria's Eastern Harbor, Egypt: Pollen, Microscopic Charcoal, and ... STANLEY, J.-D. an...

11

Partial inhibition of in vitro pollen germination by simulated solar ultraviolet-B radiation  

Energy Technology Data Exchange (ETDEWEB)

Pollen from four temperate-latitude taxa were treated with UV radiation in a portion of the UV-B (280-320 nm) waveband during in vitro germination. Inhibition of germination was noted in this pollen compared to samples treated identically except for the exclusion of the UV-B portion of the spectrum. Levels similar to maximum solar UV-B found in temperate-latitude areas failed to inhibit pollen germination significantly, while levels similar to maximum solar UV-B found in equatorial alpine locations caused partial inhibition of germination in three of the four taxa examined.

1984-01-01

12

Methods to improve the fertility of poinsettia  

British Library Electronic Table of Contents (United Kingdom)

`Success' or `Red Splendor' plants propagated by shoot tip culture or embryogenesis had higher pollen germination than those propagated by cutting. All clones of `Pepride', `Peter Star' and `Nobel Star' propagated by cutting or by embryogenesis or shoot tip culture did not have viable pollen. `Peter Star' mutants through mutagenesis could recover pollen viability. When both parents were propagated by tissue culture, fruit set increased compared to when one or both parents were propagated by cuttings. Furthermore, the number of the harvested seeds doubled per pollination set, when the tissue culture parents were used instead of cutting-propagation plants.

2008-01-01

13

Travel of Pollen in Experimental Raceways in the Endangered Texas Wild Rice (Zizania texana)  

Science.gov (United States)

... including exotic species such as Hydrilla verticellata (hydrilla), Hygrophila polysperma (hygrophila), Cryptocoryne beckettii (water trumpet), leaving little space ... ...

14

Microsporogenesis and pollen formation in cassava  

British Library Electronic Table of Contents (United Kingdom)

This article describes the complete microsporogenesis and pollen formation in cassava (Manihot esculenta Crantz) at the various developmental stages (pollen mother cell, meiosis, tetrads, early free spore, mid uninucleate, late uninucleate, binucleate and mature pollen grain). Light microscopy, transmission electron microscopy and confocal laser scanning microscopy were used for the study. Floral bud size and other inflorescence characteristics were correlated with specific stages of the microspore development. This association allows a rapid selection of floral buds with similar microspore developmental stages, useful when a large number of homogeneous cells are needed for analysis and for in vitro induction of androgenesis. This article also compares methods for digestion the exine wall ...

2011-01-01

15

The effects of an HIV project on HIV and non-HIV services at local government clinics in urban Kampala  

UK PubMed Central (United Kingdom)

BackgroundHIV/AIDS is a major public health concern in Uganda. There is widespread consensus that weak health systems hamper the effective provision of HIV/AIDS services. In recent...Full Text Available

16

Successful establishment of primary small airway cell cultures in human lung transplantation  

UK PubMed Central (United Kingdom)

BackgroundThe study of small airway diseases such as post-transplant bronchiolitis obliterans syndrome (BOS) is hampered by the difficulty in assessing peripheral airway function...Full Text Available

2009-01-01

17

Submergence-Induced Morphological, Anatomical, and Biochemical Responses in a Terrestrial Species Affect Gas Diffusion Resistance and Photosynthetic Performance  

UK PubMed Central (United Kingdom)

Gas exchange between the plant and the environment is severely hampered when plants are submerged, leading to oxygen and energy deficits. A straightforward way to reduce these shortages of oxygen and...Full Text Available

2005-09-01

18

Ovarian cancer mouse models: a summary of current models and their limitations  

UK PubMed Central (United Kingdom)

Development of mouse models representing human spontaneous ovarian cancer has been hampered by the lack of understanding of the etiology of this very complex disease. Mouse models representing the different...Full Text Available

19

Forecasting changes in amphibian biodiversity: aiming at a moving target  

UK PubMed Central (United Kingdom)

Amphibian population declines and sudden species' extinctions began to be noted at the beginning of the 1980s. Understanding the causes of the losses is hampered by our poor knowledge of the amphibian...Full Text Available

2005-02-28

20

Development of an extrachromosomal cloning vector system for use in Borrelia burgdorferi  

UK PubMed Central (United Kingdom)

Molecular genetic analysis of Borrelia burgdorferi, the cause of Lyme disease, has been hampered by the absence of any means of efficient generation, identification, and complementation...Full Text Available

2000-04-25

21

Impact of Bt corn pollen on monarch butterfly populations: A risk assessment  

UK PubMed Central (United Kingdom)

A collaborative research effort by scientists in several states and in Canada has produced information to develop a formal risk assessment of the impact of Bt corn on monarch butterfly...Full Text Available

2001-10-09

22

Small heat shock protein LimHSP16.45 protects pollen mother cells and tapetal cells against extreme temperatures during late zygotene to pachytene stages of meiotic prophase I in David Lily  

British Library Electronic Table of Contents (United Kingdom)

Plant meiotic prophase I is a complicated process involving the late zygotene and pachytene stages, both crucial for completing synapsis and recombination. Using David Lily (Lilium davidii var. Willmottiae) as our research material, we performed suppression subtractive hybridization to construct EST library of anthers at various stages of development by the pollen mother cells. From this library, we identified small heat shock protein LimHSP16.45 was highly expressed during the late zygotene to pachytene stages. Our results also showed that LimHSP16.45 was almost specifically expressed in the anther compared with the root, stem, or leaf, and in situ expression of LimHSP16.45 mRNAs showed strong signals in the pollen mother cells and tapetal cells. LimHSP16.45 could be induced by heat and c...

2011-01-01

23

Active biomonitoring of heavy metal pollution using Rosa rugosa plants  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this work was to evaluate the quality of a rural area near Faenza (Italy) by using an active biomonitoring approach, i.e., by placing homogeneous individuals of the perennial shrub Rosa rugosa in different sites throughout the area. Further sites, within the city or its environs, were used for comparison. Soil and leaves of R. rugosa were analyzed for their heavy metal content. The total heavy metal pattern of leaves closely paralleled the pattern registered in soil, with the highest content (both in total and assimilable forms) at the site in the urban area, which is exposed to heavy traffic. Pollen quality (abortiveness and viability) was also tested as a potential indicator of pollution. Pollen abortiveness was strictly related to Pb levels in leaves, while viability was inversely related to leaf Cr content. Our results suggest that R. rugosa has the potential to be a good biomonitoring system. - Rosa rugosa leaves and ...

2007-09-15

24

Active biomonitoring of heavy metal pollution using Rosa rugosa plants  

International Nuclear Information System (INIS)

The purpose of this work was to evaluate the quality of a rural area near Faenza (Italy) by using an active biomonitoring approach, i.e., by placing homogeneous individuals of the perennial shrub Rosa rugosa in different sites throughout the area. Further sites, within the city or its environs, were used for comparison. Soil and leaves of R. rugosa were analyzed for their heavy metal content. The total heavy metal pattern of leaves closely paralleled the pattern registered in soil, with the highest content (both in total and assimilable forms) at the site in the urban area, which is exposed to heavy traffic. Pollen quality (abortiveness and viability) was also tested as a potential indicator of pollution. Pollen abortiveness was strictly related to Pb levels in leaves, while viability was inversely related to leaf Cr content. Our results suggest that R. rugosa has the potential to be a good biomonitoring system. - Rosa rugosa leaves and ...

2007-09-01

25

Photosynthetic consequences of phenotypic plasticity in response to submergence: Rumex palustris as a case study  

British Library Electronic Table of Contents (United Kingdom)

Survival and growth of terrestrial plants is negatively affected by complete submergence. This is mainly the result of hampered gas exchange between plants and their environment, since gas diffusion is severely reduced in water compared with air, resulting in O2 deficits which limit aerobic respiration. The continuation of photosynthesis could probably alleviate submergence-stress in terrestrial plants, but its potential under water will be limited as the availability of CO2 is hampered. Several submerged terrestrial plant species, however, express plastic responses of the shoot which may reduce gas diffusion resistance and enhance benefits from underwater photosynthesis. In particular, the plasticity of the flooding-tolerant terrestrial species Rumex palustris turned out to be remarkable,...

2006-01-01

26

Exploring the patterns and causes of land use changes in south-west Sweden  

British Library Electronic Table of Contents (United Kingdom)

To study the causes of agricultural declines in south-west Sweden, a multi-proxy study including pollen analysis, bog surface wetness indicators and aeolian sediment influx reconstructions was carried out on the Store Mosse Bog, situated on the coastal plain of Halland. Patterns of agricultural changes during the past 6,000?years from this study were compared to one additional site on the coastal plain (Undarsmosse Bog) and to four sites in the forested upland region. First, we compared land use activity on the coastal plain and in upland regions of south-west Sweden. Three periods with reduced agricultural activities were observed, primarily in records from the coastal plain. Next, the causes for these declines were studied by comparing land use indicators in the pollen records from the S...

2011-01-01

27

Active biomonitoring of heavy metal pollution using Rosa rugosa plants  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this work was to evaluate the quality of a rural area near Faenza (Italy) by using an active biomonitoring approach, i.e., by placing homogeneous individuals of the perennial shrub Rosa rugosa in different sites throughout the area. Further sites, within the city or its environs, were used for comparison. Soil and leaves of R. rugosa were analyzed for their heavy metal content. The total heavy metal pattern of leaves closely paralleled the pattern registered in soil, with the highest content (both in total and assimilable forms) at the site in the urban area, which is exposed to heavy traffic. Pollen quality (abortiveness and viability) was also tested as a potential indicator of pollution. Pollen abortiveness was strictly related to Pb levels in leaves, while viability was ...

2007-01-01

28

Cooling device for rotors of multistage axial steam turbines  

International Nuclear Information System (INIS)

The invention concerns an improvement of a cooling device for rotors of multistage axial steam turbines by providing in the first stage of each group of turbine stages a circulation loop connecting the wheel chamber on the inlet side of the rotor disc of the first stage with the wheel chamber on its outlet side. This is to cause the cooling effect not to be hampered by gap widths of the seal in the bottom range of the rotor blades changing during operation. Design particulars are described in detail. (UWI).

29

A rapid and simple DNA extraction procedure to detect Salmonella spp. and Listeria monocytogenes from fresh produce using real-time PCR  

Science.gov (United States)

DNA isolation procedures significantly influence the outcome of PCR-based detection of human pathogens. Unlike clinical samples, DNA isolation from food samples such as fresh and fresh-cut produce has remained a formidable task and has hampered the sensitivity and accuracy of molecular methods. We...

30

Tests of Turbulators for Fire-Tube Boilers.  

Science.gov (United States)

... Originator-supplied keywords include: Turbulators, Heat transfer augmentation, Enhancement, Fire tube boilers. (Author). ...

1982-10-01

31

ELECTRON ATTACHMENT OF SEF6  

Science.gov (United States)

... attachment tube which is sketched in Fig. 1. It is mounted inside a cylindrical evacuated tube. A beam of thermal electrons ...

1961-06-20

32

Diaphragm Rupture Effects on an Expanding Flow in a Tube.  

Science.gov (United States)

... The fundamental problem of diaphragm rupture was studied experimentally to determine the effects on an expanding flow in an evacuated tube. ...

1972-08-01

33

Steam generator tube denting-criteria for tube plugging  

International Nuclear Information System (INIS)

When steam generator tube denting was identified, steps were taken to retard the rate of corrosion and to develop corrective measures if possible. Techniques were developed to determine the exact shapes of the tubes, and procedures were devised to analyze resulting strain and operating stresses. Tube plugging criteria were established, and in twelve years of operation, there has been only one instance of a forced outage due to a tube leak.

34

State-of-the-art technology for production of seamless tubes in zirconium and titanium alloys  

International Nuclear Information System (INIS)

Zircaloy fabrication plant manufactures all the necessary Zr-2 components like fuel canning tubes, calandria tubes and other rod and sheet products. This plant is having a capacity of producing about 4 lakh nos. of PHWR fuel tubes per annum. These tubes are seamless, thin walled with close dimensional tolerances and stringent mechanical properties. The plant has established all the facilities required to produce these tubes with required quality.

35

Loading of wellbores with explosives  

Energy Technology Data Exchange (ETDEWEB)

Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube ...

1983-04-26

36

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

Energy Technology Data Exchange (ETDEWEB)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.

1982-10-01

37

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

International Nuclear Information System (INIS)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).

1982-01-01

39

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

40

The Experimental Determination of the Thermodynamic and Hydrodynamic Mechanism of Augmented Flow Boiling in Tubes.  

Science.gov (United States)

Experimental results are presented for a new and unique heat transfer augmentation technique in tubes. The technique consists of inserting a porous mesh structure into the flow passage of the tube. Due to the increased degree of turbulence, both the singl...

1970-01-01

41

In service inspection for steam generator tubes  

International Nuclear Information System (INIS)

In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.

1987-11-24

42

Secondary side concept to prevent steam generator tube corrosion  

International Nuclear Information System (INIS)

Some examples are given of design adaptations, e.g. U-bend support, tube spacer grid, flow distribution baffle, triangular tube pitch, tube-tubeplate sheet connection, which reduce the tendency to various types of corrosion (stress corrosion cracking, tube denting, tube wastage, intergranular cracking). A basic diagram of the secondary circuit is shown. Oxygen, corrosion product and impurity control in the secondary circuit is described. (E.J.). 19 figs., 6 refs.

1989-05-01

43

Large-scale absolute dent evaluation campaign  

International Nuclear Information System (INIS)

Steam generator tube denting is primarily caused by build-up of corrosion products at the tubesheet and the tube support plates. The mechanism of dent growth and the identification of tubes which should be removed from service have been studied. The practical outcome has been to prevent in-service tube leaks and to avoid unnecessary plugging of large numbers of tubes. A finite element study of tubesheet deformation (of pulled leaking tubes from reactors) was undertaken. Profilometry results for characterizing dents are given. Although several modifications have been made the high resolution profilometry system performance and the results obtained have proved satisfactory. (U.K.).

44

Graphitic nano tubes and aligned nano tubes films  

Energy Technology Data Exchange (ETDEWEB)

Carbon nano tubes are easily produced in macroscopic quantities, however their characterisation and possible applications are still rather limited. We have developed a new method to make aligned nano tube films which open new opportunities, not only for basic research but also for eventual applications. With this method the tubes can be aligned either parallel or perpendicular to the surface. We give a short review of the microscopic properties of single tubes and the bulk properties of the aligned films. (author). 24 refs., 6 figs.

1996-03-01

45

Film condensation of HCFC-22 on horizontal enhanced tubes  

Science.gov (United States)

Experiments were conducted to study the condensation heat transfer characteristics of horizontal enhanced tubes. In the current experiment, six different enhanced tubes, including 26, 40 fpi low fin tubes and four three-dimensional-fin tubes, were tested. The working fluid used in the experiment was HCFC-22. Data were presented in the form of overall heat transfer coefficient at three working pressures, namely 1.32, 1.47 and 1.62 Mpa. In addition, the condensing heat transfer coefficients for the test tubes were obtained from the Wilson plot technique.

1996-01-01

46

Retrieval of chlorophyll a concentration from a fluorescence enveloped area using hyperspectral data  

British Library Electronic Table of Contents (United Kingdom)

It is acknowledged that fluorescence line height (FLH) algorithms are still hampered by the uncertainty of fluorescence peak position. The fluorescence peak moves to longer wavelengths with the increase of chlorophyll a concentration. In this article, the fluorescence enveloped area (FEA), which integrates the fluorescence height and the fluorescence peak position, was used to estimate the chlorophyll a concentration in the coastal waters of the Pearl River Estuary. The FEA algorithm was developed from in situ data of chlorophyll a concentration, total suspended matter (TSM) concentration and above-water remote sensing reflectance, which were collected at 37 sampling stations in the Pearl River Estuary during two cruises. The results showed that the FEA algorithm made a better estimation o...

2011-01-01

47

Natural gas vehicles: Technical assessment and overview of world situation  

International Nuclear Information System (INIS)

In evaluating commercialization prospects for natural gas fuelled vehicles, this paper compares the performance and emission quality of these innovative vehicles with those using conventional fuels - gasoline and diesel fuels. Assessments are made of the state-of-the-art of current technology relative to fuel storage, air/fuel mixture preparation, in cylinder combustion processes and pollution control. The analysis evidences that while natural gas is an excellent fuel for spark ignition engines, in transport applications its use is hampered by large storage volume requirements and weight. Moreover, the air/fuel mixture preparation, combustion process and exhaust-gas cleaning require a greater research and development effort to make this alternative fuel economically and environmentally competitive with conventional fuels.

1992-11-25

48

Luminescence and x-ray absorption measurements of persistent SrAl2O4:Eu,Dy powders: Evidence for valence state changes  

Science.gov (United States)

The development of new efficient afterglow phosphors is currently hampered by a limited understanding of the persistent luminescence mechanism. Radioluminescence (RL) and x-ray absorption measurements on the persistent phosphor SrAl2O4:Eu,Dy were combined to reveal possible valence state changes for the rare earth (co)dopants. Traps in the phosphor material are quickly filled when exposing thermally emptied SrAl2O4:Eu,Dy powder to x rays. On the same time scale a partial oxidation of Eu2+ to Eu3+ is observed by x-ray absorption near-edge spectroscopy (XANES), while for the trivalent dysprosium the valence state remains unchanged. The impact of these observations on the recently proposed models for persistent luminescence is discussed.

2011-08-01

49

Hydrogen in titanium alloy with 16 at% Mo  

International Nuclear Information System (INIS)

The effect of various hydrogen concentrations on the crystal lattice period and the hardness of titanium alloy was examined, the alloy containing about 16 at.% Mo (27.5 wt. % Mo) and having #beta# structure. The peculiar features of the mechanism of plastic deformation of the alloy were studied after adding hydrogen to it. A dependence of the crystal lattice period on the concentration of hydrogen was obtained for TixMoxH_2 alloy. It has been established that the hardness of the Ti-Mo alloy does not change when hydrogen is added to it. The presence of hydrogen introduces changes into the mechanism of deformation of #beta#-titanium alloy. The configuration of the inverse pole figures after rolling proves that the transverse slip process in an alloy with hydrogen is hampered, and that the coplanar slip process is developing in it.

50

Deep inelastic scattering of leptons on nuclei  

International Nuclear Information System (INIS)

Experimental studied of deep-inelastic scattering of neutrino, antineutrino, #mu#-mesons, electron reactions on He, D, Al, Fe, Au, Be, C, Ca, Ag, N nuclei conducted in recent years at different laboratories the world for consideration of modern status of the problems of R(x, Q"2) = #sigma#sub(L)/#sigma#sub(T) parameter variation and for study on nuclear effects in structural functions of nucleons are described in the review. Experimental information on measurements of the R parameter by data on EMS and SLAK groups is analyzed. It is noted that experimental data on measuring R contain essential errors that hampers unambiguous interpretation of data on nucleon structure. Present experimental data and predictions for explanation of the EMS effect are analyzed from the view point of quark and flucton models of a nucleus.

1984-06-19

51

Biological scarcity: looking beyond regulatory exteriors in Taiwan  

British Library Electronic Table of Contents (United Kingdom)

Research and bioethical policies are increasingly seen to facilitate, rather than to impede, scientific progress. Bioethical structures, nonetheless, often fail to account for or to shape the specific social surrounds in which scientific research is conducted. In Taiwan, a perceived shortage in human biological donations threatens to hamper stem cell research progress. This paper considers the stalled national biobank project and the lack of a reliable embryo supply for stem cell research, and suggests that one must look beyond regulatory structures in seeking explanations for such shortages. Specific aspects of Taiwan's democratization and social changes combine with problematic relations between patients and physicians to shape the terrain upon which human biologicals are given or withhe...

2011-01-01

52

Thoracoscopy in Children: Is a Chest Tube Necessary?  

UK PubMed Central (United Kingdom)

PurposeHistorically, a chest tube or drain has been left following a thoracic operation to allow drainage of air or fluid in the postoperative period. However, in...Full Text Available

2009-04-01

53

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters  

Science.gov (United States)

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters

1987-03-01

54

Development of technology on the material surveillance of CANDU pressure tubes  

International Nuclear Information System (INIS)

Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test ...

1997-05-21

55

Description of the ER-2 Dropwindsonde System The ... - ESPO - NASA  

Science.gov (United States)

2 illustrates the design of the launch tube, the gun barrel design of the multi-tube dispenser and integrated hardware pressure cannister. ...

56

An Optical Fiber Infrasound Sensor  

Science.gov (United States)

... We use a compliant, sealed tube helically wrapped with an optical fiber. ... 2.5 cm diameter compliant, sealed tube 10 m < length < 120 m ...

2000-09-01

57

Polysomaty analysis in diploid and tetraploid Portulaca grandiflora.  

Science.gov (United States)

Polysomaty analysis of the succulent portulaca (Portulaca grandiflora Hook.) plant was carried out using flow cytometry. For both diploid and tetraploid plants, mature leaf tissue was found to have a higher level of polysomaty than young leaf tissue. Mesophyll (MP), bundle sheath (BSP) and water storage protoplasts (WSP) were isolated from leaf tissues of diploid portulaca plants. WSP had a higher degree of endopolyploidization than MP and BSP. The ploidy distribution was also variable in different floral organs. Tetraploid plants artificially induced by colchicine treatment showed a decline in the degree of polysomaty compared to diploid plants. Tetraploid plants had more spherical leaves, a larger number of petals and lower pollen fertility than diploid plants. PMID:10936528

2000-07-28

58

Paving the Way for Invasive Species: Road Type and the Spread of Common Ragweed (Ambrosia artemisiifolia)  

British Library Electronic Table of Contents (United Kingdom)

Roads function as prime habitats and corridors for invasive plant species. Yet despite the diversity of road types, there is little research on the influence of these types on the spread of invaders. Common ragweed (Ambrosia artemisiifolia), a plant producing large amounts of allergenic pollen, was selected as a species model for examining the impact of road type on the spread of invasive plants. We examined this relationship in an agricultural region of Quebec, Canada. We mapped plant distribution along different road types, and constructed a model of species presence. Common ragweed was found in almost all sampling sites located along regional (97%) and local paved (81%) roads. However, verges of unpaved local roads were rarely (13%) colonized by the plant. A model (53% of variance expla...

2011-01-01

59

Network structure and phylogenetic signal in an artificially assembled plant-pollinator community  

CERN Document Server

Community ecologists are principally occupied with the proposition that natural assemblages of species exhibit orderliness and with identifying its causes. Plant-pollinator networks exhibit a variety of orderly properties, one of which is 'nestedness'. Nestedness has been attributed to various causes, but we propose a further influence arising from the phylogenetic structure of the biochemical constraints on the pollen diets of bees. We use an artificial assemblage as an opportunity to isolate the action of this mechanism. The properties of the network that we studied are consistent with the proposition that nestedness is caused by the phylogeny of diet range in bees, but the claim is preliminary and we propose that valuable progress in understanding plant-pollinator systems may be made through applying the techniques of chemical ecology at the community scale.

2011-01-01

60

Cracking of Alloy 800 tubing in superheated steam in a solar receiver  

Energy Technology Data Exchange (ETDEWEB)

The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the ...

1985-10-01

61

Wolsung-1 NPP - electrictal systems  

International Nuclear Information System (INIS)

... power reactors pressure tube reactors reactors THERMAL REACTORS.

1980-06-18

64

Experimental investigation for fluid flow and heat transfer in a rotating tube with twisted-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation was carried out for friction factor and heat transfer coefficient in the case of a rotating tube with a twisted-tape insert for heat transfer augmentation. The data obtained were compared with existing data for a stationary tube with a twisted-tape insert. It has been observed that the enhancement in heat transfer offsets the rise in friction factor due to rotation, with respect to a plain tube under stationary conditions. A correlation has been proposed for the data obtained.

1995-04-01

66

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

67

Common environmental allergens causing respiratory allergy in India.  

Science.gov (United States)

Respiratory allergy affects all age groups but the children are the worst affected by the respiratory allergy. Bioparticles from different biological sources are the main cause of allergy. Pollen grains, fungal spores, insect and other materials of biological origin form the most important allergen load in the air. For the efficient diagnosis of the allergy and its effective treatment it is very important to know about the prevalence, seasonal and annual variations of aeroallergens of the area. India being the climatically diversed country, there is diversity in the flora and fauna of different parts of the country. Atmospheric surveys carried out in different parts of India reveal that, Alanus nitida, Amarantus spinosus, Argemone mexicana Cocos nucifera, Betula utilis, Borasus flabellifer, Caraica papaya, Cedrus deodara, Cassia fistula, Parthenium, Chenopodium album, Dodonaea viscosa, Malotus phillipensis, Plantago ovata, Prosopis juliflora, Ricinus communis, ...

2002-03-01

68

Tube bundle for a heat exchanger  

International Nuclear Information System (INIS)

The tube bundle arrangement is suitable as reheating section of a steam generator in combination with a gas-cooled reactor. For any high-temperature section with a straightline type tube bundle, there is one inlet and one outlet collecting main; these two are arranged one opposite to the other and diametrically to the tube bundle. There are a number of lines from the inlet collecting main to the outlet collecting main; these lines are arranged axially one on top of the other and run around the tube bundle helically several times. (GL) 891 GL/GL 892 MB.

69

Steam generator tube performance  

International Nuclear Information System (INIS)

A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization.

2005-10-27

70

Control Rod Ejection Accident while Using 6- and 8-Tube IRT-4M Fuel Assemblies in WWR-SM Research Reactor Core  

Energy Technology Data Exchange (ETDEWEB)

The WWR-SM reactor at the Institute of Nuclear Physics of the Academy of Sciences (INP AS) in Uzbekistan was converted to 6-tube IRT-4M LEU (19.7%) fuel in 2009. Presently, INP intends to also use IRT-4M 8-tube FA, and a safety analysis for these 'mixed' (8-tube and 6-tube FA) cores is required by the regulatory authorities. This paper presents results of control rod ejection transient analysis for these mixed cores

2011-07-01

71

Analysis of a bayonet tube heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)

2001-01-01

72

Operating experience with Alloy 800 SG tubing in Europe  

Energy Technology Data Exchange (ETDEWEB)

'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. ...

2007-07-01

73

Operating experience with Alloy 800 SG tubing in Europe  

International Nuclear Information System (INIS)

'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. These indications ...

2007-08-19

74

Flow induced vibration mock-up test for heat exchanger tubes of PWR steam generator  

International Nuclear Information System (INIS)

It is one of the most important subjects to estimate the flow-related stability of the heat exchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected ...

2000-10-01

75

Analysis of reverse flow in inverted U-tubes of steam generator under natural circulation condition  

International Nuclear Information System (INIS)

In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse flow agrees very well ...

2008-12-01

76

Vacuum leak problem in low energy of pelletron  

International Nuclear Information System (INIS)

During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)

77

Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979  

International Nuclear Information System (INIS)

The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).

1994-10-18

78

Research on corrosion resistance of steam generator tube  

International Nuclear Information System (INIS)

In order to improve the reliability of PWR steam generators, we have performed research to improve the tubing material and tube-support-plate configuration, based on our wide operating experience, and have developed and verified Alloy TT690 as the optimum tubing material and the BEC (Broached Egg Crate) type tube-support design. In the research, we have studied the metallurgical mechanism of the alloy to improve its corrosion resistance, evaluated corrosion susceptible region quantitatively, estimated the actual environment in a steam generator and confirmed the reliability by a model boiler test over a long period. It has been verified that the steam generator with the latest design has higher reliability with respect to the corrosion resistance of tubes. (author).

79

Preparation of reactor tube by welding a porous membrane with a non-porous ceramic tube  

Energy Technology Data Exchange (ETDEWEB)

In the course of designing a catalytic porous membrane reactor for experimental studies, both inside and outside of the non-reaction zones as well as the two ends of the membrane need to be completely sealed to ensure that there is no flow across the membrane in the non-reaction zone. Experiments show that up to 50% of the total flow across the membrane may be contributed by the axial flow along the wall of the non-reaction zones if only one side of the membrane is sealed. Another problem that cannot be solved by sealing is the capillary flow of the catalyst along the tube wall into the non-reaction zones when the catalyst is doped on the membrane. One of the best ways to avoid this axial flow of catalyst would be to use non-porous tubes in the non-reaction zones and join them with the porous membrane tube. In doing so, the cost of the membrane reactor could be reduced simply because shorter membrane ...

1994-12-31

80

Numerical simulation of fluid flow and heat transfer in a concentric tube heat exchanger  

International Nuclear Information System (INIS)

In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. The difficulties associated with the simulation of a heat exchanger augmented with ...

2003-05-28

81

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

Energy Technology Data Exchange (ETDEWEB)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-01-01

82

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

International Nuclear Information System (INIS)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-03-09

83

Alloy 800 welding experience at UKAEA Springfields  

International Nuclear Information System (INIS)

Investigatins into the welding of alloy 800 at the Reactor Fuel Element Laboratories, Springfields, commenced about three years ago following an extended development programme on tube to tube plate welding of low alloy and stainless steels for the Prototype Fast Reactor. The techniques and approach developed for critical fuel element welding applications had proved equally suitable for the precision welding requirements on the much heavier sections of heat exchangers. It had been demonstrated that the same control of weld quality and profile could be achieved with consistency and the permissible range of critical parameters could be readily defined. Because of this, development work was continued to include other materials, such as alloy 800, which might be of potential use. The tungsten inert gas (T.I.G.) arc welding process is used, and the equipment, including the control system, is described. Tube to ...

84

WHO wants more use of irradiated food, calls for education programs  

International Nuclear Information System (INIS)

Short note. The World Health Organization (WHO) has taken aim at critics of irradiated food, claiming that the process has the potential to reduce the incidence of foodborne diseases such as salmonellosis, to cut postharvest food losses and to provide a wider variety of foods for consumers. 'The unwarranted rejection of this process, often based on lack of understanding of what food irradiation entails, may hamper its use in those countries which may benefit most', Dr. Jean-Paul Jardel, WHO's assistant director-general, argued following a recent international conference on the subject. Critics, including Canadians, has opposed food irradiation for years, claiming that more needs to be known about its effects. WHO said the 'vast majority' of the 54 national delegations at the conference supported use of the technology on foods ranging from grain and potatoes to poultry, tropical fruit and strawberries. WHO wants governments to educate the public on the benefits and ...

1989-02-01

85

Thickness measurement of Sn-Ag hot dip coatings on Large Hadron Collider Superconducting strands by coulometry  

CERN Document Server

Amperostatic coulometry was applied for the thickness measurement of Sn-Ag hot dip coatings, which comprise an extended Sn-Cu interdiffusion layer. Complementary measurements, notably weight loss, X-ray photoelectron spectroscopy, energy-dispersive X-ray spectroscopy, X-ray fluorescence (XRF), and dynamic secondary ion mass spectroscopy were performed in order to obtain a better interpretation of the coulometry results. Based on the experimental results presented in this article, the three potential changes observed during coulometry measurements are ascribed to (i) the entire dissolution of pure Sn, (ii) the formation of a CuCl salt layer, and (iii) the surface passivation. The measurement of the pure Sn mass is well reproducible despite strong coating thickness variations detected by XRF. Several experimental problems, in particular, a coating undercutting, hamper the determination of the Sn mass in the intermetallic Sn-Cu layer. (19 refs).

2004-01-01

86

On important matters (fire protection) related to No. 3 plant in the Hamaoka Nuclear Power Station, Chubu Electric Power Co., Inc., No. 2 plant in the Tsuruga Power Station, Japan Atomic Power Co., and No. 2 plant in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The Nuclear Safety Commission acknowledged the policy of the Agency of Natural Resources and Energy to cope with these important matters on August 8, 1984. The main contents of the investigation and deliberation were as follows, As to the prevention of the occurrence of fires, the prevention of the leak and spread of inflammable liquid and gas, the installation of protective relays and so on, the use of incombustible materials and aseismatic design and the installation of lightning arresters. As to the detection of fires and fire fighting, the proper selection and arrangement of fire detectors and extinguishers, the extinguishers which do not harm the safety function of structures and equipment, and the extinguishers which are not affected by natural phenomena. As to the reduction of the effect of fires, the proper installation of fire walls and extinguishers, and the high temperature shut off of nuclear reactors which is never hampered by any fire. (Kako, I.).

1985-01-01

87

Measurement of the antiproton/proton ratio at few-TeV energies with the ARGO-YBJ experiment  

CERN Document Server

Cosmic ray antiprotons provide an important probe for the study of cosmic-ray propagation in the interstellar space and to investigate the existence of Galactic dark matter. Cosmic rays are hampered by the Moon, therefore a deficit of cosmic rays in its direction is expected (the so-called "Moon shadow"). The Earth-Moon system acts as a magnetic spectrometer. In fact, due to the geomagnetic field the center of the Moon shifts westward by an amount depending on the primary cosmic ray energy. Paths of primary antiprotons are therefore deflected in an opposite sense in their way to the Earth. This effect allows, in principle, the search of antiparticles in the opposite direction of the observed Moon shadow. The ARGO-YBJ experiment, in stable data taking since November 2007 with an energy threshold of a few hundreds of GeV, is observing the Moon shadow with high statistical significance. Using about 1 year data, an upper limit of the antip/p flux ratio in the few-TeV ...

2009-01-01

88

Current status of a hepatitis C vaccine: encouraging results but significant challenges ahead  

DEFF Research Database (Denmark)

Persistent hepatitis C virus (HCV) infection affects 170 million people worldwide. Acute HCV infection is often asymptomatic, but many infected individuals develop persistent infections that may lead to development of end-stage liver diseases, including liver cirrhosis and hepatocellular carcinoma. Thus, an HCV vaccine that could significantly lower the chronicity rate would have a major impact on the disease burden. Unfortunately, HCV is a highly mutable virus, and escape mutations can undermine vaccine-induced virus-specific immunity. Also, HCV exists as multiple genotypes, and so genotype-specific vaccines might be required to achieve broad protection. Finally, vaccine development has been hampered by the lack of a small animal model and cell culture systems, but these are currently being established. Despite these obstacles, several vaccine candidates tested in the chimpanzee HCV model have shown some encouraging results.

2007-01-01

89

Accretion onto Supermassive Black Holes in Quasars: Learning from Optical/UV Observations  

CERN Document Server

Accretion processes in quasars and active galactic nuclei are still poorly understood, especially as far as the connection between observed spectral properties and physical parameters is concerned. Quasars show an additional degree of complexity compared to stars that is related to anisotropic emission/obscuration influencing the observed properties in most spectral ranges. This complicating factor has hampered efforts to define the equivalent of an Hertzsprung-Russel diagram for quasars. Even if it has recently become possible to estimate black hole mass and Eddington ratio for sources using optical and UV broad emission lines, the results are still plagued by large uncertainties. Nevertheless, robust trends are emerging from multivariate analysis of large spectral datasets of quasars. A firm observational basis is being laid out by accurate measurements of broad emission line properties especially when the source rest-frame is known. We consider the most widely ...

2006-01-01

90

A new approach towards anomalous fading correction for feldspar IRSL dating - tests on samples in field saturation  

Energy Technology Data Exchange (ETDEWEB)

Anomalous fading of the feldspar infrared stimulated luminescence (IRSL) signal hampers possibilities of using feldspar IRSL to obtain burial ages for sediments beyond the dating range of quartz optically stimulated luminescence. Here, we propose a new approach to quantify anomalous fading of the feldspar IRSL signal over geological burial times based on laboratory fading experiments. The approach builds on the description of the quantum mechanical tunnelling process recently proposed by Huntley [2006. An explanation of the power-law decay of luminescence. J. Phys. Condensed Matter 18, 1359-1365]. We show that our methods allow the construction of un-faded and natural IRSL dose-response curves as well as anomalous fading rates in field saturation. The predicted level of field saturation closely approximates the measured saturation level for five samples from fluvial deposits (Lower Rhine) known to be older than 1 Ma. The modelled anomalous fading rate in field ...

2008-02-15

91

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

British Library Electronic Table of Contents (United Kingdom)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-01-01

92

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

Science.gov (United States)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-12-01

93

Terminated Exploding Wire Energy Source.  

Science.gov (United States)

By placing a discharge or 'dump' tube across an exploding bridgewire load, it is possible to by-pass the electrical energy and terminate the explosion of the wire. The dump tube is triggered by a signal derived from the energy removed from the storage cap...

1965-01-01

94

Stability of Plasma Human Immunodeficiency Virus Load in VACUTAINER PPT Plasma Preparation Tubes during Overnight Shipment  

UK PubMed Central (United Kingdom)

VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas...Full Text Available

2000-01-01

95

Social media - Social media, The University of York  

Wastenet

...A directory of University social media accounts, including Facebook, Twitter and YouTube facebook, twitter, blog Social media - Social media, The ... Key: Facebook, Twitter, YouTube, Blog, LinkedIn, Flickr Missed you out? If you'd like to be included on this ...

96

Safety of pull-type and introducer percutaneous endoscopic gastrostomy tubes in oncology patients: a retrospective analysis  

UK PubMed Central (United Kingdom)

BackgroundPercutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal...Full Text Available

97

Research and development on probe inserting method into steam generator helically coiled tubes for in-service inspection  

International Nuclear Information System (INIS)

Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. ...

1979-01-01

98

Multiple neural tube defects in the same patient with no neurological deficit  

UK PubMed Central (United Kingdom)

Congenital deformities involving the coverings of the nervous system are called neural tube defects (NTDs). NTD can be classified as neurulation defects, which occur by stage 12, and postneurulation...Full Text Available

2010-01-01

99

Material and process improvements in condenser tubing  

Energy Technology Data Exchange (ETDEWEB)

The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core manufacturing process ...

2010-07-01

100

Lectin Binding of the Major Polar Tube Protein (PTP1) and its Role in Invasion  

Science.gov (United States)

... 2003)050[0600:LBOTMP]2.0.CO;2 Lectin Binding of the Major Polar Tube Protein (PTP1) ... PTP1. We, therefore, undertook a study ...

101

Intergranular attack or corrosion in a once-through model steam generator: Final report  

Energy Technology Data Exchange (ETDEWEB)

Faulting the feedwater for a 19-tube, model steam generator with 10 ppM of caustic once a week produced widespread shallow 25 to 75 micrometers (1 to 3 mils) intergranular attack (IGA) on alloy 600 tubes and an axial tube rupture at the steam-water interface after 4.8 years. An extensive investigation of the IGA damage found little correlation with major test variables beyond the indication that mill-annealed tubing was more susceptible to attack than stress-relieved tubing. The most likely cause of the tube rupture was caustic that concentrated to high levels in a porous scale on the tube at the liquid-vapor interface where there was a high available superheat. Nondestructive examination (NDE) eddy current probes underestimated the depth of IGA and were not sensitive to circumferential cracks less than 152 micrometers (6 mils) deep that ...

1987-07-01

102

Integrity of the tubes used in vertical and horizontal steam generators  

British Library Electronic Table of Contents (United Kingdom)

Statistical data on experience gained from operation of steam generators around the world are presented, problems arising in vertical and horizontal steam generators are described, and the conditions of heattransfer tubes used in them are compared.

2011-01-01

103

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between ...

1976-03-09

104

Heat transfer augmentation in 3D internally finned and microfinned helical tube  

Energy Technology Data Exchange (ETDEWEB)

Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in ...

2005-05-01

105

Enhanced tube inner surface heat transfer device and method  

Science.gov (United States)

An inner surface substrate of metal tubes is provided with a single layer of randomly distributed metal bodies bonded to the substrate, spaced from each other, and substantially surrounded by the substrate to form body void space.

1979-05-15

106

Endoscopic T-tube placement in the management of lye-induced esophageal perforation: Case report of a safe treatment strategy  

UK PubMed Central (United Kingdom)

Esophageal perforation is associated with a significant risk of morbidity and mortality. We report herein a case of lye-induced esophageal perforation managed successfully by employing endoscopic T-tube...Full Text Available

107

Conjugate heat transfer of a finned tube. Part B: Heat transfer augmentation and avoidance of heat transfer reversal by longitudinal vortex generators  

Energy Technology Data Exchange (ETDEWEB)

Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the ...

1995-08-01

108

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were ...

109

An argument for the conservative management of small traumatic pneumathoraces in populations with high prevalence of HIV and tuberculosis: an evidence-based review of the literature  

UK PubMed Central (United Kingdom)

BackgroundTraumatic pneumothoraces are common. Many are managed with tube thoracostomy. However, there is a high complication rate from chest tube placement, particularly in patients...Full Text Available

110

Substantiation of recommendations for ensuring the design service life of heat-transfer tubes used in a PGV-1000MKP steam generator  

Science.gov (United States)

We present the results obtained from tests and studies carried out on the model of tube bundles for a PGV-1000 horizontal steam generator that were conducted for experimentally substantiating the design service life of a steam generator tube bundle intended for use at new nuclear power stations equipped with a PGV-1000MKP steam generator. Measures taken to minimize the incipience and development of local corrosion damage to the heat-transfer tubes and ensure their design service life are substantiated and confirmed.

2011-03-01

111

Peripherally inserted central catheter  

Science.gov (United States)

You have a peripherally inserted central catheter (PICC). This is a tube that goes into a vein in your arm. It will help carry nutrients ...

112

Meteorological Measurement Guide  

Science.gov (United States)

... 2-22 Page 31. The mercury barometer operates on the principle of air pressure forcing the mercury column up an evacuated tube. ...

1992-01-01

113

Kinetics of salt concentration in heated crevices  

International Nuclear Information System (INIS)

In PWR steam-generators, the crevice between tube and tube-support plate tends to fill with porous deposits during operation and acts as a concentration site for chemicals in the boiler water, which may lead to corrosion of the tube and tube-support-plate. The rate of concentration, the magnitude of the concentration factor and the rate of release of solute when conditions change are important parameters for devising strategies to minimize corrosion. Values of these parameters for salt concentration have therefore been measured in a laboratory simulation of the crevice and are used to formulate a model of the concentrating process.

1985-03-01

114

Is OD peening of Alloy 800 SG tubes desirable?  

Energy Technology Data Exchange (ETDEWEB)

The shot peening of the outer surface of Alloy 800 is proposed by the steam generator supplier in order to increase the stress corrosion cracking resistance of the tubes. The benefits and drawbacks of such a treatment are evaluated, focusing on the main concern i.e. a possible enhanced tendency of stress corrosion cracking at the transition of the expanded tube-to-tubesheet joint. Stress corrosion tests as well as residual stresses measurements demonstrate no significant difference between peened and unpeened tubes at that location. The other concerns such as stability of the compressive stresses, increased risk of pitting or intergranular attack and pollution of the secondary circuit by fragmented beads appear the as minor concerns.

1992-12-31

115
116

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

117

Heat exchanger tube vibration: comparison between operating experiences and vibration analyses  

International Nuclear Information System (INIS)

Tube failures due to excessive flow-induced vibration must be avoided to assure the reliable performance of heat exchangers. Such components must be thoroughly analysed for vibration at the design stage. Several flow-induced vibration mechanisms are possible. In this paper, particular attention is given to fluidelastic instability of tube bundles subjected to liquid and two-phase cross-flow. The performance of ten operating heat exchanger components is reviewed to validate our recommended vibration analysis guidelines. Both tube failure histories and satisfactory performances are considered. The results show that a fluidelastic instability constant K=3.3 is a reasonable design criterion. (auth).

1992-12-01

119

Explosive Performance Modification by Cosolidification of ...  

Science.gov (United States)

... A booster pellet, normally Comp B, was placed in the tube and an exploding bridgewire (EBW) detonator in a plastic holder was glued in with a ...

1976-10-01

121

Dictionary of Technical Terms for Aerospace Use - S  

Science.gov (United States)

sabot: A device fitted around or in back of a projectile in a gun barrel or launching tube to support or protect the projectile or to prevent the escape of ...

122

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

123

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

124

A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants  

International Nuclear Information System (INIS)

In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.

1993-11-01

125

Protective efficiency of dendrosomes as novel nano-sized adjuvants for DNA vaccination against birch pollen allergy  

British Library Electronic Table of Contents (United Kingdom)

We evaluated the use of a novel gene porter (Den123-a nontoxic self-assembled dendritic spheroidal nanoparticle made of biodegradable monomers), aiming to enhance and improve the desired immune response in protection from allergy. Footpad DNA immunization in Balb/c mice was done three times using the Bet v 1a gene with or without Den123 with 2-week intervals followed by sensitization with rBetv1 (5mg) in alum twice in a weekly interval. Different doses of pCMV-Betv1 were used (10mg and 100mg). The protective role of different formulations was evaluated by measuring the IgG1, IgG2a and IgE antibody production, cytokine release of isolated splenocytes and b-hexosaminidase release from the RBL cells. Higher and increasing ratios of IgG2a/IgG1 were seen in mice which received plasmids in combi...

2006-01-01

126

Molecular characterization of cytoplasmic male sterility conditioned by Gossypium harknessii cytoplasm (CMS-D2) in upland cotton  

British Library Electronic Table of Contents (United Kingdom)

Cytoplasmic male sterility (CMS) is a maternally inherited trait that fails to produce functional pollen grains. The CMS system is widely employed to facilitate the utilization of heterosis in major crops. However, little is known about the CMS associated genes in Upland cotton (Gossypium hirsutum). The objective of this study was to compare CMS cotton (CMS-D2) with the cytoplasm from G. harknessii and its isogenic maintainer line with the normal fertile Upland cotton cytoplasm to identify CMS-D2 specific gene(s) and to develop CMS-specific sequence characterized amplified region (SCAR) markers. Based on Southern blot analysis using 10 mitochondrial gene-specific probes (cob, cox2, atp6, atp9, nad3, cox3, atpA, cox1, nad6 and nad9), three probes (cox3, atpA, and nad6) revealed restriction ...

2011-01-01

127

Evidence and Implications of Frequent Fires in Ancient Shrub Tundra  

Energy Technology Data Exchange (ETDEWEB)

Understanding feedbacks between terrestrial and atmospheric systems is vital for predicting the consequences of global change, particularly in the rapidly changing Arctic. Fire is a key process in this context, but the consequences of altered fire regimes in tundra ecosystems are rarely considered, largely because tundra fires occur infrequently on the modern landscape. We present paleoecological data that indicate frequent tundra fires in northcentral Alaska between 14,000 and 10,000 years ago. Charcoal and pollen from lake sediments reveal that ancient birchdominated shrub tundra burned as often as modern boreal forests in the region, every 144 years on average (+/- 90 s.d.; n = 44). Although paleoclimate interpretations and data from modern tundra fires suggest that increased burning was aided by low effective moisture, vegetation cover clearly played a critical role in facilitating the paleo-fires by creating an abundance of fine fuels. These records suggest ...

2008-03-06

128

A reassessment of the function of floral nectar in Croton suberosus (Euphorbiaceae): A reward for plant defenders and pollinators.  

Science.gov (United States)

Typically, plant-pollinator interactions are recognized as mutualistic relationships. Flower visitors, however, can potentially play multiple roles. The floral nectar in Croton suberosus has been proposed to operate as a reward for predators, especially the wasp Polistes instabilis (Vespidae), which kills herbivorous insects, while the plant has been thought to be mainly wind-pollinated. In this study, we reassessed the pollination mode of C. suberosus and the possible role of its flower visitors. Pollinator exclusion experiments demonstrated that C. suberosus should be considered a strictly entomophilous species. Inflorescences of C. suberosus were visited by a diverse entomofauna involving 28 taxa belonging to six orders; however, wasps and bees were the only visitors that carried C. suberosus pollen. The visitation rate of wasps was approximately four times that of bees. This observation, combined with the fact that the small size of bees makes effective contact ...

2010-03-11

129

Transmit-receive eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heat exchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).

1987-09-01

130

Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976  

International Nuclear Information System (INIS)

A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).

1994-10-18

131

Solar collectors with tubes partially filled with porous substrates  

Energy Technology Data Exchange (ETDEWEB)

In this work, the thermal performance of a conventional collector is improved by inserting porous substrates at the inner walls of the collector tubes. The porous substrates improve the convective heat transfer coefficient between the tube wall and the fluid. This improvement is investigated numerically and its effects on the efficiency and the useful gain of the collector are evaluated. It is found that inserting the porous substrate may raise the collector efficiency considerably, especially at high values of the overall heat loss coefficient.

1999-02-01

132

Pipe crawlers  

International Nuclear Information System (INIS)

The patent concerns pipe crawlers, i.e. apparatus capable of moving along the bores of pipes and tubes. Pipe crawlers are employed for conveying inspection equipment along the bores of pipes and tubes. The pipe crawler comprises a piston and assembly system, which controls the movement of the crawler and supports the assembly centrally within the bore of the pipe or tube. (UK).

1984-11-29

133

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

Energy Technology Data Exchange (ETDEWEB)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...

2005-07-01

134

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

International Nuclear Information System (INIS)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...

2005-10-27

135

Characterization of tube support alloys  

International Nuclear Information System (INIS)

The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions.

1985-03-01

136

Characterization of eddy current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.

1985-02-01

137

Characterization of Eddy Current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.

1985-02-01

138

Centering device  

Energy Technology Data Exchange (ETDEWEB)

A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.

1980-03-15

139

A study on the regulatory approach of KNGR multiple failure events  

Energy Technology Data Exchange (ETDEWEB)

This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in ...

2001-01-15

140

Torsional responses of double-walled carbon nanotubes via molecular dynamics simulations  

Energy Technology Data Exchange (ETDEWEB)

The buckling behaviors of double-walled carbon nanotubes (DWCNTs) under torsion are investigated by using molecular dynamics (MD) simulations. The effect of length on the torsional buckling behaviors of DWCNTs is examined for the first time. The simulation results show that the DWCNTs experience gradual or simultaneous buckling deformations depending on their lengths. In addition, the effect of the inner tube in a DWCNT on its torsional buckling behavior is also examined. The presence of the inner tube triggers van der Waals (vdW) interactions between it and the outer tube and thus leads to a stiffening effect of the DWCNT against torsional deformation. Whether the ends of the inner tube are free or fixed and whether it is subject to a torque or not, the critical torque and the critical torsional angle of the outer tube are only marginally affected.

2008-11-12

141

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-15

142

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-01

143

Superphenix 1 steam generator fabrication  

Energy Technology Data Exchange (ETDEWEB)

The Superphenix 750-MW (thermal), once-throughtype steam generators are the result of over 10 years of intensive research and development. Detailed design and manufacture of the components lasted from 1977 to 1982. The main difficulties encountered during the construction of these prototype units concerned: demonstration of satisfactory high-temperature properties of Alloy 800 tubes; proven resistance of tube welds to thermal fatigue and of structures and shells to sodium/ water reaction effects; prevention of the tube bundle to flow-induced vibration; necessity of manual welding of shells to prevent hot cracking hazards related to the boron content of the steel; and welding of heat exchange tubes. None of these difficulties, however, invalidated initial major design choices, but provided a wealth of technical and technological experience and knowledge for the steam generators of the future. Plans for ...

1985-02-01

144

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)

2010-09-01

145

Investigations on denting phenomenon in monel tubes  

International Nuclear Information System (INIS)

Denting phenomenon as experienced in PWR steam generators has been investigated in the laboratory of Monel-400 tubes and C-steel baffles combination. Isothermal corrosion tests have been carried out by exposing capsules, containing a crevice between Monel-400 tubes and C-steel plugs, in plausible corrodents at 300"0C. Results indicated that the denting phenomenon is strongly influenced by the chloride content in the solution. In addition, it is a time dependent process. Stress exerted on the tubes by the growth of corrosion product on the outside surface of C-steel plugs are enough to deform the Monel tubes. The results have been discussed on the basis of accelerated corrosion of C-steel by hydrolyzable metal chlorides. (author).

1981-05-01

146

Evaluation, testing and database generation of pitting corrosion characteristics of domestic steam generator tubing material  

Energy Technology Data Exchange (ETDEWEB)

Accumulation of Chloride and Cupric ions under the sludge on the steam generator tubing surface in the area between tube sheet and the first tube support is known to be the main reason for the pitting corrosion. In addition to those ions, oxygen, pH, temperature, heat treatment history, contests of minor elements such as C, S or Ti in the alloy are also influencing the material's the pitting corrosion resistance. a series of autoclave pitting test was conducted to evaluate the pitting corrosion characteristics of the domestically produced alloy 690 tubing material and compare with that of INCO manufactured material. 16 refs., 44 figs., 5 tabs. (Author)

1998-04-01

147

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-07-01

148

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-06-01

149

Top of tubesheet cracking in Bruce A NGS steam generator tubing - recent experience  

Energy Technology Data Exchange (ETDEWEB)

During the Bruce A Nuclear Generating Station (BNGS-A) Unit 1 1997 planned outage, a dew point search method identified a leak in one steam generator(SG) tube. Subsequently, the tube was inspected with all available eddy current probes and removed for examination. The initial inspection results and metallurgical examination of the removed tube confirmed that the leak was due to intergranular attack/stress corrosion cracking (IGA/SCC) emanating from the secondary side of the tube at the top of the tubesheet location. Subsequently, eddy current and ultrasonic indications were found at the top of the tubesheet of other Alloy 600 SG tubes. To investigate the source of the indications and to validate the inspection probes, sections of 40 tubes with various levels of damage were removed. The metallurgical examination of the removed sections showed that both secondary ...

1998-07-01

150

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...

2005-07-01

151

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

International Nuclear Information System (INIS)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...

2005-10-27

152

Characteristics of U-tube assembly design for CANDU 6 type steam generators  

Energy Technology Data Exchange (ETDEWEB)

Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant operation, steam generator ...

1996-06-01

153

CFD simulation of steam generator tube rupture thermal-hydraulics  

Energy Technology Data Exchange (ETDEWEB)

Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial mass, momentum and ...

2004-07-01

154

A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP  

International Nuclear Information System (INIS)

Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. ...

2010-10-01

155

Failure analysis report: Heat exchanger tubes geothermal binary power plant, Magma Electric Company, East Mesa, California  

Energy Technology Data Exchange (ETDEWEB)

Radian received twelve sections of heat exchanger tubing from the Magma Electric Company's 10MW(e) East Mesa binary geothermal power plant. Three tube sections were received from each of four shell and tube heat exchangers (HX1, Hx6, HX8, and Hx10) of the isobutane vaporizer train. All samples were taken from the upper few rows of tubes. Two months later, four more tube sections were received. These four sections were taken from the lower rows of heat exchangers 1, 6 (two sections), and 10. Radian was requested to investigate the cause of severe pitting failure of these heat exchanger tubes. This report is part of a continuing DOE effort to gain insight into the service life of component materials employed in geothermal energy utilization.

1982-05-01

156

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present ...

2011-01-15

157

Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report  

Energy Technology Data Exchange (ETDEWEB)

Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...

1987-07-01

158

Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report  

International Nuclear Information System (INIS)

Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...

159

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical ...

2002-03-01

160

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-11-16

161

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-07-01

162

Studies on improvement of heat transfer characteristics in high temperature heat exchangers, (1)  

International Nuclear Information System (INIS)

Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and with the Reynolds number of 2.9 x 10"3 to ...

1978-01-01

163

NPP steam generator: materials and water-chemical regime  

International Nuclear Information System (INIS)

The main reasons of tube failures in steam generators (SG) are considered. 1.Stress corrosion craining which has 28% of SG (most of them have stainless steel tubes). 2. Corrosion loss of metal, which accounts for 24% of tubes (phosphate corrosion due to addition of PO into water). 3.Denting-peripheral pressing of tubes in the openings of the foundation plates by the corrosive products, which are formed on internal surface of drillings in the foundation plates made of carbon steel. 4.Separation of a plating layer on tube panels. 5.Dratting-corrosion. 6.Metal fatigue. A series of experiments were conducted to study the influence of material selection on tube reliability (stainless steel 304, inconel-600, mone-400, incalloy-800). The problem of increase of SG elements reliability is a complex one and can be solved by direct selection of material, proper control of ...

164

FRAMATOME's continuous efforts to improve steam generator corrosion resistance  

International Nuclear Information System (INIS)

Construction of the French PWR nuclear program started in the early 70s, at the time a number of operating plants in the US were being affected by the first corrosion problems. Since, at that time, its construction program was in an early stage, FRAMATOME was able to make modifications on the first units to improve steam generator resistance to corrosion. For instance, full depth expansion of the tubes in the tube-sheet using an explosive process (Westex) was performed on Fessenheim 1 steam generators already installed on site. Later on, continuous operating experience was being obtained in the US, before startup of the French units. This allowed FRAMATOME to react rapidly and take immediate corrective actions at the design stage, during fabrication and sometimes even on site in order to mitigate the risk of corrosion in the steam generators. FRAMATOME is confident that the present design of its steam generator models, including a large number ...

165

Experimental verification of the horizontal steam generator boil-off transfer degradation at natural circulation  

Energy Technology Data Exchange (ETDEWEB)

The presentation summarises the highlights of experimental results obtained for VVER type horizontal steam generator heat transfer, primary side flow pattern, and mixing in the hot collector during secondary side boil-off with primary at single-phase natural circulation. The experiments were performed using the PACTEL facility with Large Diameter (LD) steam generator models, with collector instrumentation designed specifically for these tests. The key findings are as follows: (1) the primary to secondary heat transfer degrades as the secondary water inventory is depleted, following closely the wetted tube area; (2) a circulatory flow pattern exists in the tube bundle, resulting in reversed flow (from cold to the hot collector) in the lower part of the tube bundle, and continuous flow through the upper part, including the tubes that have already dried out; and (3) mixing of the hot leg flow entering the ...

1997-12-31

166

Experimental Evaluation of Tude Support Plate Crevice Chemistry  

Energy Technology Data Exchange (ETDEWEB)

A test methodology for measuring temperature, impedance, pH, and electrochemical potential distributions within a sludge-packed tube support plate crevice in a laboratory test is described. The method successfully showed that there were large concentration gradients between the tube and tube support plate sides of the crevice. The testing also showed that strong bases concentrated more effectively than strong acids, and that the crevice pH, when exposed to seawater-based solutions, increased with increasing superheat and decreasing bulk concentration. The large variations in the crevice chemistry observed under heat transfer were eliminated upon shutdown. These new test data suggest that it might be beneficial to evaluate the variation in the extent of stress corrosion cracking with tube support plate elevation found in some steam generators in light of local chemistry changes, as well as the variation ...

2001-05-08

167

Development of a high performance air heater through use of an evacuated tube cover design  

Science.gov (United States)

Development of a high performance air heater through use of an evacuated tube cover design is described. The cover design utilizes evacuated fluorescent light tubes laid parallel in a close packed array to form an inner transparent glazing over a conventional metal absorber plate with flow behind the plate. A tempered flat glass plate was used as an outer glazing. Both clear and infrared reflective (IR) tubes were investigated. Solar transmittance tests indicate that the clear tube array has a higher transmittance than two flat sheets of low-iron glass. The IR coating produced substantial transmittance loss. Thermal conductance tests indicate that the tubes behave similar to two flat glass sheets with a vacuum in between. The IR reflective coating was only marginally effective at reducing heat conductance. Final prototype designs are presented along with collector performance ...

1980-01-01

168

Constant extension rate (CERT) testing of alloy 690 and 800 nuclear steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Constant extension rate (CERT) tests were performed on Alloy 690 and Alloy 800 nuclear steam generator tubing specimens. For the Alloy 690 specimens, tests were performed in deaerated 10% sodium hydroxide solutions at 315 deg C with a +100 mV applied potential. For the Alloy 800 specimens, tests were performed in deaerated 5% sodium hydroxide solutions at 343 deg C with no applied potential. The test specimens were machined from tubing which was produced by different manufacturing processes and in different heat treated conditions. The Alloy 690 tubing was tested in six different thermomechanical conditions, while the Alloy 800 tubing was tested in four different thermomechanical conditions. The results from the test program include a complete microstructural examination using light-optical and scanning electron microscopy. The CERT test results (such as maximum stress achieved and crack morphology) are ...

1994-12-31

169

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table case. The intrinsic ...

2000-03-01

170

Torsion of moderately thick hollow tubes with polygonal shapes  

British Library Electronic Table of Contents (United Kingdom)

A simple formulation is presented for torsion analysis of hollow tubes with polygonal shapes. Thicknesses of segments of cross section can be different. Governing equations in term of Prandtl's stress function are used to derive the formulas. The derived formulas are so simple that computations can be carried out with a pocket calculator. Several examples are presented to show the accuracy and efficiency of the formulation. The obtained results are verified by accurate finite element solutions. It will be seen that the derived formulas can be useful for analysis of thin-walled and moderately thick-walled hollow tubes.

2007-01-01

171

Thermally isolated pipeline  

Energy Technology Data Exchange (ETDEWEB)

The pipelines is provided for gases, particluarly helium, at temperature of about 1000/sup 0/C (pressure about 40 bar) and is used as the connection be tween a gas cooled high temperature reactor and a heat load. The pipe consists of a temperature-resistant inner tube, which is composed of several pipe sections, which are supported on ball bearings, and a gas tight pressurised outer tube. There are supports and insulation between the two tubes. The sub-claims concern fixing of and bearings for the pipe sections. The description is very detailed and supplemented by drawings.

1980-08-28

172

Testing of 12Kh18N10T tube steel samples tendency to intergranular corrosion  

International Nuclear Information System (INIS)

Tendency of 12Kh18N10T steel tube samples to intergranular corrosion (IGC) is investigated by an express electrochemical method in the 10% solution of H_2SO_4+0.0025 g/l of KCNS. Tendency to IGC is mainly detected on the internal surface of tube samples. It is shown that the tendency to INC under plant conditions is caused by surface carburization under its incomplete purification from the graphite lubrication.

1993-01-01

173

Stress corrosion cracking of Alloy 600 using the constant strain rate test  

International Nuclear Information System (INIS)

Nuclear grade production tubing of Alloy 600 was evaluated for stress corrosion cracking (SCC) susceptibility in high purity water at 365, 345, 325, and 290 C. Reverse tube U-bend specimens provided crack initiation data and constant extension rate tests were employed to determine the crack velocities experienced in th crack propagation stage. Initial results indicate that a linear extrapolation of data received from high temperature tests can be used to predict the service life of steam generator tubing that has been plastically deformed or is continually deforming by ''denting.''.

174

Longitudinal emittance oscillation in a superconducting drift tube linac  

International Nuclear Information System (INIS)

In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.

1995-05-01

175

Heat transfer characteristics of laminar flow in internally finned tubes under various boundary conditions  

Science.gov (United States)

Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.

1994-06-01

176

Feasibility study on scheme of disposing spent guide tubes at Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The author describes feasibility study on the scheme of disposing spent guide tubes at Daya Bay nuclear power plant, including scheme selection, packing cask design, disposal operation and technological process, budget estimation and safety evaluation. The research results show that the new scheme is feasible on technology, and reasonable on budget. If the scheme is adopted to dispose the spent guide tubes at Daya Bay nuclear power station, it can not only save large funds, but also accumulate experience on disposing non-compressible low and intermediate level solid radioactive wastes produced at nuclear power station for the country

1998-12-01

177

Evaluation of optimum sheath electric field for selective production of metallic carbon nanotubes  

International Nuclear Information System (INIS)

We estimate the optimum electric field at the sheath edge and the minimum interval among the nanotubes to promote the growth of armchair-type nanotubes (metallic character) as a function of the tube length. On the basis of the electric charge distribution in a nanotube and the optimum electric filed E*_1 at the tip of a nanotube evaluated using the Hueckel-Poisson method, we calculate the structure of the electric field lines outside a nanotube in the sheath region. As the tube length increases, the E*_1 decreases. To maintain the chemical activity at the tip, the sheath electric field must be decreased. We show the decreasing rate of the sheath field to the tube length.

2006-03-21

178

Design parameters for tube cavity receivers in solar power plants  

Energy Technology Data Exchange (ETDEWEB)

The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.

1981-01-01

179

Application of neutron radiography to visualization of multiphase flows  

Energy Technology Data Exchange (ETDEWEB)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-04-01

180

Application of neutron radiography to visualization of multiphase flows  

International Nuclear Information System (INIS)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-01-01

181

Analysis of laminar flow heat transfer in uniform temperature circular tubes with tape inserts  

Science.gov (United States)

Constant property, laminar flow heat transfer in a semicircular tube with uniform wall temperature has been analyzed to define the lower bound of heat transfer augmentation in circular tubes with twisted-tape inserts. Two thermal boundary conditions, which correspond to the two extremes of the fin effect of twisted tapes encountered in practical applications, are considered. Numerical solutions, employing finite-difference formulations for the governing momentum and energy equations were carried out for the thermal entrance region and for fully developed flow.

1986-05-01

182

An investigation of turbulent convection heat transfer performance in spiral spring coil inserted tubes  

International Nuclear Information System (INIS)

This paper presents the results of the experimental investigation on heat transfer and fluid friction characteristics of a class of spiral spring coil used as a tube side forced convection heat transfer augmentation devices. Based on a lot of experimental data, the heat transfer correlation and fluid friction correlation revised by temperature were reached in terms of linear regression. At the same time, proper criteria were used to evaluate the economic performance of the spiral spring inserted tube according to the demand of practical application and some probing analysis were made.

1996-01-01

183

A new procedure for cutting out the broken thermocouple tubes inside the deep holes in the tube plate of moisture re-heater at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The scenario of the development of a new procedure for cutting out the broken protective wells for thermocouples inside the deep holes in the tube plate in the moisture re-heater (MSR) at Daya Bay nuclear power station is presented. Focused in the innovation and improvement of the self-made tools, the new procedure produced an effective method to cut out swing long inserts stuck inside the deep holes. (authors)

2005-09-01

184

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

185

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

186

The interventional treatment for biliary recurrent obstruction after palliative T tube drainage in patients with obstruction due to cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To explore the interventional method to treat biliary recurrent jaundice after T tube drainage in patients with malignant obstructive jaundice due to cholangiocarcinoma. Methods: 7 biliary metallic stents were placed in 7 patients with recurrent jaundice after T-tube drainage in cholangiocarcinoma cases. Results: Stent placement was once successful in all 7 cases with successful rate of 100%. For all cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that of preoperation together with subsidence of jaundice satisfactorily for 100% after the treatment. Conclusions: Percutaneous placement of biliary metallic stents was effective economic, minimal invasive and safe for palliation of biliary recurrent jaundice after T tube drainage in cholangiocarcinoma-induced obstructive jaundice

2002-10-01

187

Strain Rate Effects on Ultimate Strain of Copper  

Science.gov (United States)

... Figure 3a. PETN Filled Tube Specimen Detonated by Exploding Bridgewire Specimen POLYETIILLENE END-CAP "1- 901am WALL IHICKNESS ...

1979-05-01

188

Steam Generator Group Project: Annual report, 1985  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...

1987-04-01

189

Steam Generator Group Project: Annual report, 1985  

International Nuclear Information System (INIS)

This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...

190

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

192

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe ...

1999-07-15

193

Indium(III) Compounds Containing the Neopentyl Substituent ...  

Science.gov (United States)

... learn more about the thermal stability of InNP2 Me, a sample contained in a previously evacuated tube was heated at 100°C for 13 days. Neither ...

1989-02-24

194

History of Bioterrorism: Botulism  

Medline Plus

... Pan Flu Preparedness YouTube is Your Friend Additional Resources ... Response Hurricane Readiness in High-Risk Areas: Survey Results Elements of ...

195

Far-out Pathways to Space: Great Guns? - ISTP  

Science.gov (United States)

The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he ...

196

Far-out Pathways to Space: Great Guns?  

Science.gov (United States)

Turbine Afterword The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he envisioned...

2011-09-03

197

Development of the SSC (Superconducting Super Collider) trim coil beam tube assembly  

Energy Technology Data Exchange (ETDEWEB)

The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.

1987-01-01

198

Development of a FeCoNb Alloy to be used in Eddy Current ...  

Science.gov (United States)

... Accession Number : ADD336001. Title : Development of a FeCoNb Alloy to be used in Eddy Current Probes for Testing Ferromagnetic Tubes,. ...

199

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

200

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

201

Central Venous Access Catheters (CVAC) and Gastrostomy (Feeding) Tubes  

Science.gov (United States)

... of CVACs, including tunneled catheters (Hickman or Broviac), peripherally inserted central catheters (also called PICC lines or long lines), ...

202

Burner systems  

Energy Technology Data Exchange (ETDEWEB)

A burner system particularly useful for downhole deployment includes a tubular combustion chamber unit housed within a tubular coolant jacket assembly. The combustion chamber unit includes a monolithic tube of refractory material whose inner surface defines the combustion zone. A metal reinforcing sleeve surrounds and extends the length of the refractory tube. The inner surface of the coolant jacket assembly and outer surface of the combustion chamber unit are dimensioned so that those surfaces are close to one another in standby condition so that the combustion chamber unit has limited freedom to expand with that expansion being stabilized by the coolant jacket assembly so that compression forces in the refractory tube do not exceed about one-half the safe compressive stress of the material; and the materials of the combustion chamber unit are selected to establish thermal gradient parameters across the combustion chamber ...

1984-07-10

203

BAM: Staphylococcal Enterotoxins  

Science.gov (United States)

... Dialysis tubing. Cellulose casing of 1-1/8 inches flat width and an average pore diameter of 48 Angstrom units is used (12,000-14,000 mol wt exclusion). ...

204

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

British Library Electronic Table of Contents (United Kingdom)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...

2011-01-01

205

Application of Combined Enhanced Techniques for Design of Highly Efficient Air Heat Transfer Surface  

British Library Electronic Table of Contents (United Kingdom)

In order to reduce the size and cost of heat exchangers, an air-side wavy fin-and-tube heat transfer surface with three-row tubes needs to be replaced by two-row tubes with some appropriate enhancing techniques. The major purpose of the present paper is to search for such new structure by numerical simulation. First, longitudinal vortex generators of Delta-winglet type are tried. The influence of number and of arrangement of the winglets on the performance of the heat transfer surface is studied in detail. The numerical results show that the fin with two winglets aligned spanwise in the front and rear of each tube (Fin W6) has higher heat transfer capability than other enhanced structures with vortex generators, but it still unable to meet the heat transfer requirement. Then a combination ...

2012-01-01

206

A New Tool for Accurately Measuring the Inside Diameter of a ...  

Science.gov (United States)

Page 1. AD-769 272 A NEW TOOL FOR ACCURATELY MEASURING THE INSIDE DIAMETER OF A GUN BARREL, LONG TUBE, OR SIMILAR ...

1973-08-29

207

120-MM Gun Tube Erosion Including Surface Chemistry ...  

Science.gov (United States)

... with dynamic gridding capability to account for material ablation, as well as the addition of energy sources and heat transfer augmentation due to ...

1997-10-01

208

(12) United States Patent  

Science.gov (United States)

Sep 19, 2005 ... within a sealed tube to control the environment to which a sample mounts are better suited to handling the very small crystal is exposed. ...

209

Zinc/air battery R and D research and development of bifunctional oxygen electrode: Tasks I and II, Final report  

Energy Technology Data Exchange (ETDEWEB)

Studies were conducted of the bifunctional oxygen electrode. The development of a rechargeable metal-oxygen (air) cell has been hampered to a great extent by the lack of a stable and cost effective oxygen electrode capable of use during both charge and discharge. The first type of bifunctional electrode consists of two distinct catalytifc layers. The oxygen reduction catalyst layer containing a supported gold catalyst is in contact with a hydrophilic nickel layer in which evolution of oxygen takes place. Loadings of gold from 0.5 to 1.0 mg/cm/sup 2/ were investigated; carbon, graphite, metal, and spinel oxides were evaluated as substrates. The second part of the research effort was centered on developing a reversible oxygen electrode containing only one catalytic layer for both reduction and evolution of oxygen. The work was directed specifically to the study of perovskite type of oxides with the composition AA/sup 1/BO/sub 3/ where A is an element of the ...

1986-12-01

210

Understanding feline heartworm infection: disease, diagnosis, and treatment.  

Science.gov (United States)

Feline heartworm disease is a very different clinical entity from canine heartworm disease. In cats, the arrival and death of immature heartworms in the pulmonary arteries can cause coughing and dyspnea as early as 3 months postinfection. Adult heartworms suppress the function of pulmonary intravascular macrophages and thus reduce clinical disease in chronic feline heartworm infection. Approximately 80% of asymptomatic cats self-cure. Median survival time for symptomatic cats is 1.5 years, or 4 years if only cats living beyond the day of presentation are considered. Aberrant worm migration is more frequent than it is in dogs, and sudden death can occur with no prior clinical signs. The bacterial endosymbiont Wolbachia likely contributes to the inflammatory pathology of heartworm disease, but its role is not yet fully clear. Unfortunately, the diagnosis, treatment, and management of feline heartworm disease are far from simple. Antemortem diagnosis is hampered by ...

2010-11-01

211

Synthesis, characterization, and evaluation of a novel bifunctional chelating agent for the lead isotopes {sup 203}Pb and {sup 212}Pb  

Energy Technology Data Exchange (ETDEWEB)

Radioisotopes of Pb(II) have been of some interest in radioimmunotherapy and radioimmunoimaging (RII). However, the absence of a kinetically stable bifunctional chelating agent for Pb(II) has hampered its use for these applications. {sup 203}Pb (T{sub 1/2}=52.02 h) has application potential in RII, with a {gamma}-emission that is ideal for single photon emission computerized tomography, whereas {sup 212}Pb (T{sub 1/2}=10 h) is a source of highly cytotoxic {alpha}-particles via its decay to its {sup 212}Bi (T{sub 1/2}=60 min) daughter. The synthesis of the novel bifunctional chelating agent 2-(4-isothiocyanotobenzyl)-1,4,7,10-tetraaza-1,4,7,10-tetra-(2-carbamoyl methyl)-cyclododecane (4-NCS-Bz-TCMC) is reported herein. The Pb[TCMC]{sup 2+} complex was less labile to metal ion release than Pb[DOTA]{sup 2-} at pH 3.5 and below in isotopic exchange experiments. In addition to increased stability to Pb{sup 2+} ion release at low pH, the bifunctional TCMC ligand was ...

2000-01-01

212

Synthesis, characterization, and evaluation of a novel bifunctional chelating agent for the lead isotopes "2"0"3Pb and "2"1"2Pb  

International Nuclear Information System (INIS)

Radioisotopes of Pb(II) have been of some interest in radioimmunotherapy and radioimmunoimaging (RII). However, the absence of a kinetically stable bifunctional chelating agent for Pb(II) has hampered its use for these applications. "2"0"3Pb (T_1_/_2=52.02 h) has application potential in RII, with a #gamma#-emission that is ideal for single photon emission computerized tomography, whereas "2"1"2Pb (T_1_/_2=10 h) is a source of highly cytotoxic #alpha#-particles via its decay to its "2"1"2Bi (T_1_/_2=60 min) daughter. The synthesis of the novel bifunctional chelating agent 2-(4-isothiocyanotobenzyl)-1,4,7,10-tetraaza-1,4,7,10-tetra-(2-carbamoyl methyl)-cyclododecane (4-NCS-Bz-TCMC) is reported herein. The Pb[TCMC]"2"+ complex was less labile to metal ion release than Pb[DOTA]"2"- at pH 3.5 and below in isotopic exchange experiments. In addition to increased stability to Pb"2"+ ion release at low pH, the bifunctional TCMC ligand was found to have many other ...

2000-01-01

213

Greater Green River Basin production improvement project, Phase 1: Site characterization report  

Energy Technology Data Exchange (ETDEWEB)

Several tight, naturally-fractured, gas-productive formations in the Greater Green River Basin (GGRB) in Wyoming have been exploited using conventional vertical well technology. Typically, hydraulic fracture treatments must be performed in completing these wells to increase gas production rates to economic levels. However, with the maturation of horizontal drilling technology hydraulic fracture treatments may not be the most effective method for improving gas production from these tight reservoirs. Two of the most prolific tight gas reservoirs in the Green River Basin, the Frontier and the Mesaverde, are candidates for the application of horizontal well completion technology. The objective of the proposed project is to apply the DOE`s technical concept to the Second Frontier Formation on the western flank of the Rock Springs Uplift. Previous industry attempts to produce in commercial quantities from the Second Frontier Formation have been hampered by lack of ...

1996-05-01

214

Accumulation of carbon in northern mire ecosystems  

Energy Technology Data Exchange (ETDEWEB)

The basic feature in the functional ecology of any mire ecosystem is retardation of the effective decay of organic material resulting in a conspicuous accumulation of plant debris as peat overtime. The carbon accumulation process is slow, and climatic change may have an impact on the carbon cycle of peatlands, therefore, it has been of interest to study the rate of carbon accumulation by geological methods from dated peat strata. The approach is hampered by several facts. First, the mires vary enormously as to their vegetation and hydrology and hence their production and decay properties. It follows that a great number of study sites are needed. Second, the peat in mires expands both vertically and laterally, and this requires a spatial reconstruction of carbon accumulation within a mire basin. Third, simple geological methods cannot account for the actual rate of carbon accumulation in peat, and finally, an additional carbon sink in the mire ecosystems can be the ...

1996-12-31

215

Transient burnout in flow reduction condition  

International Nuclear Information System (INIS)

A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author).

216

Tracheal laceration during intubation of a double-lumen tube and intraoperative fiberoptic bronchoscopic evaluation through an LMA in the lateral position -A case report-  

UK PubMed Central (United Kingdom)

A 76-year-old, 148-cm woman was scheduled for right upper lobectomy. A 32 Fr left-sided double lumen tube was placed using a conventional technique. Despite several attempts under fiberoptic bronchoscope-guidance,...Full Text Available

2011-04-01

217

Thermal/hydraulic tests of tube supports in a multi-tube steam generator model  

International Nuclear Information System (INIS)

Tube supports used in the tube bundles of PWR steam generators have consisted of mechanical devices located at intervals along the tube bundle. The presence of tube supports creates regions of restricted flow with altered flow patterns and increased pressure drop. An additional and very important effect is also the possibility of local complete vaporization or dryout occurring in the tube/support flow passage and crevices. The thermal/hydraulic conditions at which dryout occurs are of particular interest because of the possibility of the deposition of dissolved solids with the occurrence of dryout. As long term build-up of solid deposition could have a deleterious effect, knowledge of the conditions at which dryout occurs would possibly provide a means to avoid this build-up. A test program, sponsored by the Steam Generator Project Office of the Electric Power Research Institute, ...

1985-03-01

218

Steam generator design improvements for the candu wolsung nuclear power plant  

International Nuclear Information System (INIS)

Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.

1978-01-01

219

Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection  

Energy Technology Data Exchange (ETDEWEB)

Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.

2000-05-01

220

Radiative Heat Transfer Augmentation in High Temperature Combustion Systems with Application to Radiant Tube Burners. Final Report, April 1987-March 1990.  

Science.gov (United States)

Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...

1990-01-01

221

PWR steam generator chemical cleaning process  

International Nuclear Information System (INIS)

Some of the origins of corrosion encountered in the secondary side of pressurized water reactor steam generators are:-sludge accumulation (a mixture of metal oxides, primarily magnetite and copper) on tube sheet and attack of tube support plates by aggressive impurities leading to denting. Although Electricite de France has not suffered from these problems, it has developed a chemical cleaning process to dissolve corrosion products at both locations. (author).

1986-10-13

222

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

223

Manual corrosion  

Energy Technology Data Exchange (ETDEWEB)

In the aim to fight against tubes corrosion of geothermal wells which exploit the aquifer of Dogger reservoir in the Parisian basin, injection of corrosion inhibitors in the geothermal fluid has been generalized since 1989 by using an additive injection tube in the bottom of the well, allowing the protection of the two wells from the geothermal doublet. 3 annexes. 46 refs. 13 tabs. 9 figs.

1994-09-01

224

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube ...

2003-12-01

225

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings ...

2003-12-01

226

Esophageal perforation following bite of inner tube of automobile tyre: An unusual cause of barotrauma  

UK PubMed Central (United Kingdom)

An 8-year-old child presented with severe chest pain and respiratory distress after he accidentally bit an automobile tyre tube which burst into his mouth. The chest radiograph revealed left-sided pneumothorax....Full Text Available

2010-01-01

227

Energy conservation via heat transfer enhancement. Quarterly progress report, October 1-December 31, 1979  

Science.gov (United States)

Contacts with researchers, manufacturers, and users of enhanced heat transfer equipment are summarized. The Technical Literature file and the Patent File continue to be updated; the Patent File is the source for a patent technology report now in draft form. Application studies on a rationally-based friction correlation for internally-finned tubes and on the evaluation of candidate tube-side enhancements for OTEC applications are reported. The technology study on enhancement of spray evaporation is also discussed.

1979-01-01

228

Effective stress of a 4.2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall`s resistivity requirement ({sigma}*t = 2E5 {Omega}{sup {minus}1}). For a 4.2 K beam tube the Cu thickness is 100 {mu}m (RRR=30,6.7 T, {sigma}=2E9{Omega}{sup {minus}1}m{sup {minus}1}). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam tube ...

1993-05-01

229

Effective stress of a 4. 2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall's resistivity requirement ([sigma]*t = 2E5 [Omega][sup [minus]1]). For a 4.2 K beam tube the Cu thickness is 100 [mu]m (RRR=30,6.7 T, [sigma]=2E9[Omega][sup [minus]1]m[sup [minus]1]). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam ...

1993-05-01

230

Condenser replacement at Unterweser nuclear power station  

International Nuclear Information System (INIS)

In spite of extensive cooling water studies premature damage due to corrosion occurred on the CuZn20Al condenser tubes. It was then decided to incorporate new titanium-tubed condensers during the annual overhauls of 1983 and 1985 and also take ameliorating measures up to the exchange of individual condensers. (orig.).

231

CERAMIC MEMBRANES FOR HYDROGEN PRODUCTION FROM COAL  

Energy Technology Data Exchange (ETDEWEB)

The preparation and performance of membranes for application to hydrogen separation from coal-derived gas is described. The membrane material investigated was dense amorphous silica deposited on a suitable support by chemical vapor deposition (CVD). Two types of support materials were pursued. One type consisted of a two-layer composite, zeolite silicalite/{alpha}-Al{sub 2}O{sub 3}, in the form of tubes approximately 0.7 cm in diameter. The other type was porous glass tubes of diameter below 0.2 cm. The first type of support was prepared starting from {alpha}-Al{sub 2}O{sub 3} tubes of 1{micro}m mean pore diameter and growing by hydrothermal reaction a zeolite silicalite layer inside the pores of the alumina at the OD side. After calcination to remove the organic template used in the hydrothermal reaction, CVD was carried out to deposit the final silica layer. CVD was carried out by alternating exposure of the surface with ...

2004-04-01

232

Bounding ingestion stream-tube determination via a CO tracer  

Energy Technology Data Exchange (ETDEWEB)

A gas tracer technique based on carbon monoxide and a commercial automotive exhaust gas analyser has been applied to wind tunnel models of waterjet propulsion systems intakes. The post-processing and interpretation of the carbon monoxide concentration signals has yielded high resolution measurements of the bounding ingestion stream-tubes. (orig.) With 3 figs., 1 tab., 8 refs.

1998-05-01

233

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

Energy Technology Data Exchange (ETDEWEB)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree ...

2003-07-01

234

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

International Nuclear Information System (INIS)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree ...

2003-10-05

235

Advances in enhanced heat transfer: 1987  

Energy Technology Data Exchange (ETDEWEB)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-01-01

236

Advances in enhanced heat transfer: 1987  

International Nuclear Information System (INIS)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-08-09

237

Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET ...

2002-07-01

238

Processing fine-grained and superplastic AZ31 Mg tubes for hydroforming  

Energy Technology Data Exchange (ETDEWEB)

The microstructures and mechanical properties of the AZ31 Mg tubes fabricated by one-pass forward piercing tube extrusion operated at 250-400 C and 10{sup -2}-10{sup 0} s{sup -1} are examined. The grain size is refined from the initial {proportional_to}75 {mu}m grain size down to {proportional_to}1.5 {mu}m. The room temperature tensile elongation along the extrusion direction also increases from {proportional_to}13% for the as-received billet up to 51%. The highest superplastic elongation of 610% was obtained as tensile loaded at 300 C and 2 x 10{sup -4} s{sup -1}, and high strain rate superplasticity of 406% and 502% was achieved at 300 C and 400 C with a high strain rate of 1 x 10{sup -2} s{sup -1}. Preliminary hydroforming or tube bulging at room temperature has demonstrated the feasibility. Hydroforming at elevated temperature of 200 C or above should exhibit much more promising results, utilizing the capability of LTSP ...

2004-07-01

239

Prevention of pitting corrosion on copper tubes in central hot water supply systems by UV photochemical decomposition of residual chlorine  

Energy Technology Data Exchange (ETDEWEB)

After confirming that residual chlorine in tap water, which is regarded as one of the major cause of pitting corrosion, can be decomposed/removed by the irradiation of UV light, effect of dechlorinated water obtained based on this principle on the prevention of pitting corrosion, generation and growth, of the copper tubing was investigated by a corrosion test simulated the actual system in high buildings. (1) Low pressure type mercury lamp easily decompose/remove the residual chlorine. (2) If the dechlorinated water is supplied from the initial stage of copper tube usage, potential of the copper tube remains at the level of 100 mV/SCE and the generation of pitting corrosion is not observed. (3) Even when pitting corrosion is already found, switching to dechlorinated water in the midway reduces the potential of the copper tube down to 50 - 70 mV level, at the same time completely restricting the growth ...

1988-03-25

240

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be effective: (1) Removal of ...

1998-11-15

241

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope holds considerable promise for quality ...

1978-01-01

242

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2006-07-01

243

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2005-11-20

244

Determination of water level profile along heat exchange tubes of horizontal steam generator PGV 1000 M  

International Nuclear Information System (INIS)

A mathematical model is described for determining the level profile along the length of heat exchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with exposed top tube rows may occur even in some permissible operating ...

245

Augmentation of heat transfer in a tube with an oscillating thin plate. Shindohen sonyu ni yoru enkannai netsudentatsu sokushin  

Energy Technology Data Exchange (ETDEWEB)

An attempt is made to augment the heat transfer efficiency by means of inserting an oscillating thin plate into a tube of the shell and tube heat exchanger. However, the heat transfer augmenting mechanism has not been fully explained. To elucidate this heat transfer augmenting mechanism, an investigation was given on the heat transfer characteristics of a tube inlet at its preliminary run area when a double-hinged oscillating thin plate is inserted in the inlet. As a result of the experiment, the heat transfer augmentation in the tube as a result of inserting the double-hinged oscillating thin plate was found effective when the preliminary inlet run area is treated as the object. However, in comparison of the effect with the heat transfer in a fully developed turbulent region, it was {eta}- 1. The result thus obtained explains that no sufficient turbulence can be obtained when the deflection angle of ...

1991-09-01

246

Regional inventory of environmental health: experience in Southeastern France; Tableau de bord regional sante-environnement en Provence-Alpes-Cotes d'Azur: retour d'experience  

Energy Technology Data Exchange (ETDEWEB)

In 2004, the Southeastern France regional council asked the regional health observatory to conduct an environmental health inventory to i) identify environmental health problems in this area; ii) examine the relations between environmental exposure to pollutants and human health; and iii) help public officials to identify priorities in this area. We collected and validated data from national, regional and local institutions, constructed environmental (levels of emissions and pollutants), health (mortality, incidence, prevalence) and behavioral indicators (e.g., complaints about odors), and compared these over time and between places when possible. For each topic, we summarized current knowledge about the links between environment and health. In southeastern France, as in other French areas, indoor air pollution, home and leisure injuries and other home-related risks are public health issues. Other topics are more significant or particular to southeastern France: transportation (air ...

2005-07-15

247

Palynostratigraphy and palaeoenvironment of the Middle Jurassic Sortehat Formation (Neill Klinter Group), Jameson Land, East Greenland  

Energy Technology Data Exchange (ETDEWEB)

The grey-black mudstones of the Sonehat Formation form part of the Middle Jurassic fill of the Jameson Land Basin in East Greenland. The formation is exposed in the southernmost part of the north south-trending, Mesozoic rift system in East Greenland that was part of the epeiric seaway betaveen East Greenland and Norway. Sedimentological observations of the Sortehat Formation indicate deposition in an offshore marine setting that was typically low energy and periodically oxygen-deficient but was influenced by storm currents on occasion. Detailed palynological studies of the Sortehat Formation have resulted in the definition of theee palynological assemblage zones recognised at four localities, namely Enhjoerningen Dal and Pelion (north Jameson Land), the type section at Sortehat (central Jameson Land) and Albuen at Neill Klinter along Hurry Inlet (south-east Jameson Land). In stratigraphic order, these zones are termed the Botryococcus Assemblage Zone, the Naennoceratopsis gracilis- ...

2003-07-01

248

Monitoring, sampling and analysis of fine particulates -- Results and experiences from DOE's Federal Energy Technology Center  

Energy Technology Data Exchange (ETDEWEB)

The overall goal of the DOE fine particulate program is to ensure that the best science and technology is available for any regulatory decision-making related to the health and environmental impacts of ambient fine particulate matter and regional haze. Interest primarily lies in the particulate fraction having aerodynamic diameters of 2.5 microns and less (PM2.5). Particulates of this size are the focus of the newly established National Ambient Air Quality Standards. As such, the Federal Energy Technology Center (FETC) is establishing a fine particulate sampling station at the Center's Pittsburgh site located in South Park Township, PA. This sampling station is one of a group of stations scattered throughout Pennsylvania, West Virginia, and Ohio that constitute the Upper Ohio River Valley Project. The station is equipped with a full complement of fine particulate and gaseous monitors including the following: (1) R and P Sequential FRM sampler, (2) Grimm PM2.5 continuous ...

1999-07-01

249

(/sup 14/C)sucrose uptake and labeling of starch in developing grains of normal segl barley  

Energy Technology Data Exchange (ETDEWEB)

Previous work showed that the segl mutant of barley (Hordeum vulgare o Betzes) did not differ from normal Betzes in plant growth, photosynthesis, or fertility, but it produced only shrunken seeds regardless of pollen source. To determine whether defects in sucrose uptake or starch synthesis resulted in the shrunken condition, developing grains of Betzes and segl were cultured in (/sup 14/C)sucrose solutions after slicing transversely to expose the endosperm cavity and free space. In both young grains (before genotypes differed in dry weight) and older grains (17 days after anthesis, when segl grains were smaller than Betzes), sucrose uptake and starch synthesis were similar in both genotypes on a dry weight basis. To determine if sucrose was hydrolyzed during uptake, spikes of Betzes and segl were allowed to take up (fructose-U-/sup 14/C)sucrose 14 days after anthesis and the radioactivity of endosperm sugars was examined during 3 hours of incubation. Whereas less ...

1984-01-01

250

Ultra-high temperature strength properties on Mod.9Cr-1Mo steel  

Energy Technology Data Exchange (ETDEWEB)

A sodium-water reaction drove from the single tube break in steam generator of FBR might overheat labor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. This study clarified the tensile and creep properties of Mod.9Cr-1Mo steel at ultra-high temperature which will be used in evaluation of the tube burst by sodium-water reaction. The strain rates for tensile test are from 10%/min to 10%/sec, and creep-rupture time is maximum 277sec. The range of test temperature is 700degC to 1300degC. The main results obtained were as follows; (1) The evaluation data on the relationship between tensile strength and strain rate and creep-rupture strength in shorter time on Mod.9Cr-1Mo steel were ...

2000-03-01

251

The Cause of an Eddy Current Signal Noise from a Steam Generator Tube and its Effect on the Detectability of a Crack  

International Nuclear Information System (INIS)

An eddy current inspection has been applied for a pre-service and in-service examination of a steam generator in nuclear power plants. The experience from the inspection of steam generators showed that many plants had an excessive number of tubes with eddy current noise signals over several hundreds, which originated from manufacturing anomalies. The plants in U.S suffered significant downstream inspection costs, history reviews, and diagnostic testing because some signals resembled flaws and others masked a flaw. These lessens learned resulted in issuing the guidelines for steam generator tubing specifications and repair, in order to reduce the number of anomalous signals in the tubes and also to provide the requirement of a signal to noise ratio by applying a field type examination with bobbin coil eddy current probes at a manufacturing process. Besides the noise signals of a bobbin coil eddy current probe from ...

2008-05-01

252

Predicting optimum vortex tube performance using a simplified CFD model  

International Nuclear Information System (INIS)

The Ranque-Hilsch tube is a particular type of vortex tube device. The flow enters the device tangentially near one end and exits from the open ends of the tube. The inlet air is of a uniform temperature throughout while the outputs are of different temperatures. One outlet is hotter and the other is colder than the inlet air. This device has no moving parts and does not require any additional power for its operation other than that supplied to the device to compress the inlet air. It has, however, not been widely used, mainly because of its low efficiency. In this paper, a simplified 2-dimensional computational fluid dynamics model for the flow in the vortex tube is developed using FLUENT. This model makes use of the assumption of axial symmetry throughout the entire flow domain. Compared to a three-dimensional computational solution, the simplified model requires significantly less computational time. ...

2004-05-09

253

Fracture inspection by BHTV logging through a vinyl chloride tube; Enbi pipe ga sonyusareta kosei deno BHTV ni yoru kiretsu chosa  

Energy Technology Data Exchange (ETDEWEB)

A borehole televiewer (BHTV) logging was conducted to investigate cracks in bored wells. The logging process shoots ultrasonic waves onto bore walls and utilizes reflection waves from the bore walls. If the bores are filled with muddy water, or the ultrasonic waves can pass through even if vinyl chloride tubes have been inserted after excavation, the state of the bore walls can be investigated in principle. Conventional optical scanners are, however, incapable of making this investigation. The BHTV logging can be used for identifying lithofacies from reflection intensities from bore walls (it depends on sound impedance of rocks), not to speak of finding cracks. As a result of making logging upon setting time windows from 105 to 145 {mu} sec in a bored well inserted with a vinyl chloride tube, cracks in the bore wall were identified clearly through the vinyl chloride tube. If the distance between the bore wall and the vinyl ...

1997-05-27

254

Application of new corrosion-resistance superheater tubings for a 500 C, 100 Kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy plant  

Energy Technology Data Exchange (ETDEWEB)

A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were investigated in detail. Furthermore, the design conception and basic ...

1999-11-01

255

Analysis of defect detection in steam generator tubes of FBR, under support plates and in the presence of sodium using multi-frequency eddy current algorithms  

International Nuclear Information System (INIS)

In the present paper we estimate the effect of sodium in the in-service inspection of non-magnetic steam generators tubes using eddy current technique and eddy current probes based on a differential double bobbin coil configuration. Experimental measurements of defects signals in steam generator tubes of fast breeder reactor are compared with simulations results of a two-dimensional axisymmetric finite element code to validate a reliable electromagnetic model of the system (eddy current coils, steam generator tube, defect) when there is no sodium on the outer steam generator tube surface. The electromagnetic code is used to evaluate the sodium band and sodium layer signals when a defect is located under steam generator support plate. Using a multi-frequency algorithm, its parameters are determined in the 'no sodium condition' (there is no sodium on the outer steam generator tube ...

2007-04-22

256

A review of heat exchanger tube bundle vibrations in two-phase cross-flow  

International Nuclear Information System (INIS)

Flow-induced vibration is an important concern to the designers of heat exchangers subjected to high flows of gases or liquids. Two-phase cross-flow occurs in industrial heat exchangers, such as nuclear steam generators, condensers, and boilers, etc. Under certain flow regimes and fluid velocities, the fluid forces result in tube vibration and damage due to fretting and fatigue. Prediction of these forces requires an understanding of the flow regimes found in heat exchanger tube bundles. Excessive vibrations under normal operating conditions can lead to tube failure. Relatively little information exists on two-phase vibration. This is not surprising as single-phase flow induced vibration; a simpler topic is not yet fully understood. Vibration in two-phase is much more complex because it depends upon two-phase flow regime, i.e. characteristics of two-phase mixture and involves an important consideration, which is the void ...

2004-05-01

257

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

258

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather than a vertical one. (Author)

1994-10-01

259

Summary of denting mechanism and kinetic studies with seawater  

International Nuclear Information System (INIS)

Studies at Commissariat a l'Energie Atomique (CEA) have been under way for three years in an attempt to find methods for preventing and stopping denting. Tests have been performed in 28 model boilers (Ajax with U tubes and Clarinette with straight tubes). In these boilers, with continous injection and blowdown, and heat flux is about 40 W X cm"-"2 (126900 Btu/ft"2 X h). The kinetics of denting has been studied with different levels of faulting. Some high-temperature electrochemical measurements established the mechanism of denting in the boiler tests. Denting kinetics can be rationalized in terms of three main parameters: faulting level, heat flux, and relative mechanical strength of the tube compared to the support plate.

260

Special eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

Until a decade ago, only the differential bobbin type eddy current probe was considered necessary for reliable heat exchanger tube inspection. The introduction of different tube materials, manufacturing processes and a variety of service induced failures has greatly increased the demands of eddy current testing. Optimized probe designs enhanced by improved instrumentation can help satisfy some of these demands. Some of the more difficult inspection problems are detection of circumferential cracks, fretting wear under non-ferromagnetic support plates and shallow internal defects. Reliable detection and sizing of such defects is often made more difficult by the fact they frequently occur in defect prone regions such as under tubesheets or support plates and in transition regions of finned tubes. Probe designs effective in overcoming these difficulties exist. This paper describes a number of such probes and their performance.

1986-11-17

261

Research of time-domain equivalent circuit method in solving dispersion of coupled-cavity traveling-wave tube  

International Nuclear Information System (INIS)

In this paper, a time-domain equivalent circuit method is applied to solve dispersion of coupled-cavity travelling-wave tube (CCTWT). First, the time-domain circuit equations of CCTWT coupled-cavity chain are deduced from the equivalent circuit model. Then, the equations are solved numerically by fourth-order Runge-Kutta method and a program CTTDCP is developed using MATLAB. Last, a L-band CCTWT is calculated using CTTDCP and the cavity pass-band of this tube is computed to be 1.08-1.48 GHz, which is consistent with the experimental results and the simulation results of electromagnetic code and demonstrates the validity of the time-domain equivalent circuit method. In addition, a new design method which uses the equivalent circuit method and electromagnetic simulation together to optimize the cold cavity characteristics of CCTWT is proposed. (authors)

2008-09-01

262

Relative performance of supercritical binary geothermal power cycles with in-tube condensors in different orientations  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of the performance of binary power cycles utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation. The utilization of these concepts will improve the net geofluid effectiveness (net plant output per unit mass of geofluid) about 20% over that of a conventional binary power plant. The major prerequisite for this improvement is the achievement of integral, countercurrent condensation. Results are presented for testing of the performance of the condenser at different tube inclinations. The performance in the vertical orientation is better than in either the horizontal or inclined orientations. 7 refs., 8 figs.

1989-01-01

263

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

264

Process for filling tubular plates for lead batteries. Verfahren zum Fuellen von Rohrplatten fuer Bleiakkumulatoren  

Energy Technology Data Exchange (ETDEWEB)

The following method is proposed as a supplement to main patent 2419107, which deals with the filling of tubular plates surrounding the lead cores: the flat materials which are used to produce the jacket tubes are prepared before forming into jacket tubes by a film producing aqueous carboxy-methyl cellulose solution closing the pores. The preparation can be done by coating the flat material with a soluble foil. After pressing the paste in, the tubular plates are dried and after cooling are dipped into sulphuric acid with a specific gravity of 1.24 g/cm/sup 3/. The carboxy-methyl cellulose is dissolved and the permeability of the tube walls for electrolyte is restored after only 15 minutes.

1981-06-19

265

Post-CHF heat transfer with water and refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)

1996-06-01

266

Offshore drilling rig with enclosed work area  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the working conditions for the operators of drilling rigs, the work area for handling of pipes and tubes is arranged on a main deck convered by a drill deck, which has openings closable by hatch cover panels. The derrick is enclosed in a cover, from which tunnels extend out over the drill deck and comprises lifting means for handling of pipes and tubes between the decks. The tunnels are connected to the cover of the derrick by raised enclosures permitting the swinging of pipes from a horizontal position in the tunnel to a vertical position in the derrick, and vice versa. There is a door, at least at one of the enclosures, permitting handling of especially long objects. Basically, the handling of pipes and tubes can be performed within areas fully protected from the weather.

1987-12-01

267

Mining User Comment Activity for Detecting Forum Spammers in YouTube  

CERN Document Server

Research shows that comment spamming (comments which are unsolicited, unrelated, abusive, hateful, commercial advertisements etc) in online discussion forums has become a common phenomenon in Web 2.0 applications and there is a strong need to counter or combat comment spamming. We present a method to automatically detect comment spammer in YouTube (largest and a popular video sharing website) forums. The proposed technique is based on mining comment activity log of a user and extracting patterns (such as time interval between subsequent comments, presence of exactly same comment across multiple unrelated videos) indicating spam behavior. We perform empirical analysis on data crawled from YouTube and demonstrate that the proposed method is effective for the task of comment spammer detection.

2011-01-01

268

Metallurgical Investigation of a Prematurely Failed Concentric Reducer Tube Used in a Hot-Rolling Mill  

British Library Electronic Table of Contents (United Kingdom)

A concentric reducer tube, which was a part of the top exit roughing hydraulic descaler in a hot strip mill failed prematurely under working pressure. A detailed metallurgical investigation comprising physical examination, optical microscopy, scanning electron microscopy, and electron probe microanalysis was carried out to find out the genesis of the failure. Physical examination revealed cracks located symmetrically around the circumference of the tube that ran along its full length, up to the weld beads at both ends. Optical microscopy of etched samples revealed a banded ferrite-pearlite structure and the existence of forging folds near the change-in-section(160? fillets). Cracks were found to initiate from these forging folds. No structural abnormalities were found in the weld beads and...

2007-01-01

269

Mechanical design of a PERMCAT reactor module  

International Nuclear Information System (INIS)

The PERMCAT is a membrane reactor proposed for processing fusion reactor plasma exhaust gas: tritium removal is obtained by isotopic swamping operating in counter-current mode. In this work, a membrane reactor using a permeator tube of length about 500 mm produced via diffusion welding of Pd-Ag thin foils is described. An appropriate mechanical design of the membrane module has been developed in order to avoid any significant compressive and bending stresses on the very long and thin wall permeator tube: two expanded bellows have been applied to the Pd-Ag tube, so that it has been pre-tensioned before operating. The elongation of the metal permeator under hydrogenation has been theoretically estimated and experimentally verified for properly designing the membrane reactor.

2007-02-01

270

Life extension of boilers using weld overlay protection  

Energy Technology Data Exchange (ETDEWEB)

The presentation describes the status of modern weld overlay technology for refurbishment, upgrading and life extension of boilers. The approaches to life extension of boilers include field overlay application, shop-fabricated panels for replacement of the worn, corroded waterwall and shop-fabricated overlay tubing for replacement of individual tubes in superheaters, generating banks and other areas. The characteristics of weld overlay products are briefly described. Also discussed are successful applications of various corrosion-resistant overlays for life extension of boiler tubes in waste-to-energy boilers, coal-fired boilers and chemical recovery boilers. Types of corrosion and selection of weld overlay alloys in these systems are also discussed. (orig.) 14 refs.

1998-12-31

271

Improvement of the PGV-1000 steam generator in-vessel components  

International Nuclear Information System (INIS)

Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.

1988-01-01

272

Impact of Tubing Length on Hemodynamics in a Simulated Neonatal Extracorporeal Life Support Circuit  

British Library Electronic Table of Contents (United Kingdom)

Abstract During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8 Fr Biomedicus arterial and a 10 Fr Biomedicus venous cannula were connected to the pseudopatient. One fourth inch tubing was used for both the arterial and the venous line. A ...

2010-01-01

273

Heat transfer augmentation in liquid metal reactor steam generators  

International Nuclear Information System (INIS)

The use of heat transfer augmentation devices has been proposed as a means for reducing the cost of steam generators for advanced LMR designs by approximately 25%. Experimental results are presented for two types of enhancers in the form of a twisted-tape and a core-tube insert in the steam tube of a 13.1-m-long, sodium-heated single-tube test section. Test parameters were prototypical of liquid metal reactor (LMR) steam generator design for a once-through high-pressure steam cycle. Heat transfer results are compared with the no-insert case on an overall and local basis. Although both augmentations increased overall performance, the mechanisms were different.

274

Fluidelastic instability of heat exchanger tube bundles; Review and design recommendations  

Energy Technology Data Exchange (ETDEWEB)

This paper reports that fluidelastic instability is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to cross-flow. Most of the available data on this topic have been reviewed from the perspective of the designer. Uniform definitions of critical flow velocity for instability, damping, natural frequency and hydrodynamic mass were used. Nearly 300 data points were assembled. The authors found that only data from experiments where all tubes are free to vibrate are valid form a design point of view. In liquids, fluid damping is important and should be considered in the formulation of fluidelastic instability. From a practical design point of view, we conclude that fluidelastic instability may be expressed simply in term of dimensionless flow velocity and dimensionless mass-damping. There is no advantage in considering more sophisticated models at this time. Practical design guidelines are discussed.

1991-05-01

275

Evaluation of validity of the RELAP5/MOD3 flow regime map for horizontal tubes  

Energy Technology Data Exchange (ETDEWEB)

RELAP5/MOD3 code was developed for western type power water reactors with vertical steam generators. Thus, this code should be validated also for VVER design with horizontal steam generators. The validation work, which has been started in Lappeenranta University of Technology (LUT), has already shown some weaknesses of the code. For example the flow inside a steam generator horizontal tube in some accident cases is not correctly modelled by the code. It may be the result of erroneous prediction of the flow regime. The aim of the study is the attempt of verification of the flow regime map, which is used in the RELAP5/MOD3 computer code for two-phase flow in horizontal tubes. (18 refs.).

1996-12-31

276

Assessment of degradation processes in corrosion resistant steels in nuclear power engineering  

International Nuclear Information System (INIS)

The possible corrosion damage is discussed of the CrNi and CrNiMo types steels used as structural materials in WWER type nuclear power plants. It includes point and slot corrosion, corrosion cracking and corrosion fatigue as well as corrosion denting. Also discussed are test procedures that simulate operating conditions and are used for assessing the properties of metallurgical products (sheets and tubes) used in nuclear power engineering. Briefly described is a system for testing the said products in an aqueous medium while keeping the test parameters in a narrow range for a long time. Under the defined temperature, pressure and corrosion medium composition, the test specimens in this system can mechanically be loaded, both statically and dynamically or a temperature gradient can be produced at the tube-tube plate joint. (Z.M.). 1 fig., 1 tab., 10 refs.

1987-12-01

277

p-Nonyl-phenol: an estrogenic xenobiotic released from "modified" polystyrene.  

UK PubMed Central (United Kingdom)

Alkylphenols are widely used as plastic additives and surfactants. We report the identification of an alkylphenol, nonylphenol, as an estrogenic substance released from plastic centrifuge tubes. This...Full Text Available

1991-05-01

278

User's manual for the BNW-I optimization code for dry-cooled power plants. [MFCIRI Code  

Science.gov (United States)

This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)

1977-01-01

279

The Mechanism and the Magnitude of Flow Boiling Augmentation in Tubes with Discrete Surface Roughness Elements (III).  

Science.gov (United States)

Related to other research on the effectiveness of flow boiling heat transfer augmentation using various types of turbulators this investigation comprises a definitive study of the effect of large discrete roughness elements on heat transfer over the entir...

1972-01-01

280

Study of nuclear materials by neutron scattering.  

Science.gov (United States)

Following studies on fiber and sheet texture of hexagonal crystal system in 1988, work has been extended to tube texture. Using the zircaloy-4 fuel cladding of Wolsung-type reactor as specimen, six pole figures for different crystallographic planes were m...

1990-01-01

281

Staphylococcal Enterotoxin B: Solid-Phase Radioimmunoassay  

UK PubMed Central (United Kingdom)

An immunoassay employing 125I-labeled enterotoxin B and polystyrene tubes coated with specific antibody was used for assaying purified and crude enterotoxin. Antibody was adsorbed to untreated...Full Text Available

1971-11-01

282

Solid-Phase Radioimmunoassay of Total and Influenza-Specific Immunoglobulin G  

UK PubMed Central (United Kingdom)

An antigen-antibody system of polystyrene tubes coated with immunoglobulin antibody was used for quantitating immunoglobulins. A similar radioimmunoassay method was adapted for a viral antigen-antibody...Full Text Available

1972-02-01

283

Site Error There's a problem with ... - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Bending moments recorded by sensors on the aluminum tube. ... the escape rocket motor, tests also were made with the escape tower and rocket .... Incoming photographic data will be electronically converted and processed ...

284

Problems and prospects of using structural materials for horizontal steam generators  

British Library Electronic Table of Contents (United Kingdom)

Prospects for using new structural materials instead of Grade 08Kh18N10T steel for making heat-transfer tubes for horizontal steam generators with the purpose to increase their service life from 30?40 to 60 or more years are considered.

2011-01-01

285

Prediction of refrigerant void fraction in horizontal tubes using probabilistic flow regime maps  

Energy Technology Data Exchange (ETDEWEB)

A state of the art review of two-phase void fraction models in smooth horizontal tubes is provided and a probabilistic two-phase flow regime map void fraction model is developed for refrigerants under condensation, adiabatic, and evaporation conditions in smooth, horizontal tubes. Time fraction information from a generalized probabilistic two-phase flow map is used to provide a physically based weighting of void fraction models for different flow regimes. The present model and void fraction models in the literature are compared to data from multiple sources including R11, R12, R134a, R22, R410A refrigerants, 4.26-9.58 mm diameter tubes, mass fluxes from 70 to 900 kg/m{sup 2} s, and a full quality range. The present model has a mean absolute deviation of 3.5% when compared to the collected database. (author)

2008-04-15

286

Novel Technique for Aerodynamic Force Measurement in Shock Tubes.  

Science.gov (United States)

For aerodynamic force measurement in the ISL shock tunnel, the authors have developed a novel measurement technique. Its key feature is a mounting support, which releases the test model and tightens it again after a free flight duration of 10 to 15 millis...

1989-01-01

287

Modeling of soluble impurities distribution in the steam generator secondary water  

Energy Technology Data Exchange (ETDEWEB)

A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

1997-12-31

288

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube`s inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 ...

1993-05-01

289

Minimal distensibility of pulmonary capillaries in avian lungs compared with mammalian lungs  

UK PubMed Central (United Kingdom)

Previous physiological studies suggest that avian pulmonary capillaries behave like almost rigid tubes. We made morphometric measurements to determine the diameter of the capillaries in chicken...Full Text Available

2008-02-01

290

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

Energy Technology Data Exchange (ETDEWEB)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our ...

1996-06-01

291

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

International Nuclear Information System (INIS)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our ...

292

Membrane nanotubes induced by aqueous phase separation and stabilized by spontaneous curvature  

UK PubMed Central (United Kingdom)

Tubular membrane structures are widespread in eukaryotic cells, but the mechanisms underlying their formation and stability are not well understood. Previous work has focused on tube extrusion from...Full Text Available

2011-03-22

293

Magnetic Fields in Massive Stars. II. The Buoyant Rise of Magnetic Flux Tubes Through the Radiative Interior  

CERN Document Server

We present results from an investigation of the dynamical behavior of buoyant magnetic flux rings in the radiative interior of a uniformly rotating early-type star. Our physical model describes a thin, axisymmetric, toroidal flux tube that is released from the outer boundary of the convective core, and is acted upon by buoyant, centrifugal, Coriolis, magnetic tension, and aerodynamic drag forces. We find that rings emitted in the equatorial plane can attain a stationary equilibrium state that is stable with respect to small displacements in radius, but is unstable when perturbed in the meridional direction. Rings emitted at other latitudes travel toward the surface along trajectories that largely parallel the rotation axis of the star. Over much of the ascent, the instantaneous rise speed is determined by the rate of heating by the absorption of radiation that diffuses into the tube from the external medium. Since the time scale for this ...

2003-01-01

294

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?  

UK PubMed Central (United Kingdom)

ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available

2011-02-01

296

Fluid dynamics analysis of a Ranque-Hilsch vortex tube  

International Nuclear Information System (INIS)

Fluid dynamic analysis of a commercial, counter-flow Ranque-Hilsch Vortex Tube (Rh vt), Ex air 25 s cfm, has been performed in this work both experimentally and numerically; in particular Rh vt cooling power and temperature separation performances have been tested in both direct cooling employment (jet impingement) and indirect cooling employment (supplying cold plates). Experimental techniques, used in this work, revealed several difficulties to produce detailed information about velocity and temperature fields inside the tube and at both the exits. Hence numerical simulation of the flow inside the tube has been conducted using the commercial Cfd code Fluent 6.3.26. Compressible, turbulent, high swirling flow inside Rh vt has been simulated by using both Rans and Les approaches. In particular several turbulence closures have been used in the Rans simulations and results have been compared with Les ones. Large Eddy ...

2008-05-01

297

Evaluation of the Widal tube agglutination test for the diagnosis of typhoid fever among children admitted to a rural hdospital in Tanzania and a comparison with previous studies  

UK PubMed Central (United Kingdom)

BackgroundThe diagnosis of typhoid fever is confirmed by culture of Salmonella enterica serotype Typhi (S. typhi). However, a more rapid, simpler,...Full Text Available

298

Evaluation of new corrosion-resistant superheater tubing in high-efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

Field corrosion tests were conducted on eight single tube materials and two welded overlay materials in three typical Japanese waste incineration plants in an effort to develop new corrosion-resistant superheater tubes capable of functioning efficiently under temperature and pressure conditions of 500 C and 100 kgf/cm{sup 2}-g in high-efficiency waste-to-energy (WTE) plants. Austenitic alloys containing higher concentrations of chromium, nickel, and molybdenum [Cr + Ni + Mo] showed excellent corrosion-resistant properties, and the new alloys JHN24 and HR30M showed good corrosion resistance. Different corrosion rates found in each of the three plants were explained by differences in operating conditions, such as gas temperature, concentration of molten salts resulting from chlorine (Cl) content of deposits, heavy metal (zinc oxide [ZnO] + lead oxide [PbO]) content, etc. It was confirmed that the corrosion rate of materials positioned in the ...

1998-07-01

299

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K{sup Iscc}, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most ...

2002-07-01

300

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

International Nuclear Information System (INIS)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K"I"s"c"c, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most corrosive ...

2002-05-05

301

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

302

Does My Child Have ADHD?  

Medline Plus

September 14, 2010 ADHD: Signs, Symptoms, Research NIMH researchers talk about the symptoms of ADHD as well as the latest research. Download this video. Watch on YouTube. Transcript Announcer: ADHD- Attention Deficit Hyperactivity Disorder- is one of the ...

303

Cross flow boiling in tube bundles  

Science.gov (United States)

This report contains two main subjects. One is the newly started investigation of cross flow boiling in tube bundles. The heat transfer information at this condition is of significant importance to horizontal steam generator design. The other one is the continuation of the research on boiling heat transfer in confined spaces. The research on cross flow boiling in tube bundles has been started. The Freon loop has been modified for higher flow and higher two phase quality. The test section design is finished and is under fabrication presently. The new instrumentation system is also established. The test matrix has been planned. The research on boiling in confined spaces proceeds steadily. This problem is of great importance to the boiling induced corrosion in the steam generator crevices between the tube and the support plate. In the report of 1981, detailed results were presented for analysis of single phase flow, two phase ...

1982-10-01

304

Coolant rate distribution in horizontal steam generator under natural circulation  

Energy Technology Data Exchange (ETDEWEB)

In the presentation the major factors determining the conditions of NCC (Natural Coolant Circulation) in the primary circuit and in particular conditions of coolant rate distribution on the horizontal tubes of PGV-1000 in NPP with VVER-1000 under NCC are considered. 5 refs.

1997-12-31

305

Conservative management of post traumatic thoraco diaphragmatico biliary fistula  

UK PubMed Central (United Kingdom)

We report herein a case of thoraco diaphragmatico biliary fistula in a 24-year-old male who was managed conservatively with antibiotics and tube thoracostomy and had complete radiological clearance.

2010-10-01

306

Comparative Inhibitory Effects of Antigen and Antibody in the Staphylococcal Enterotoxin Solid-Phase Radioimmunoassay System  

UK PubMed Central (United Kingdom)

A solid-phase radioimmunoassay employing 125I-labeled enterotoxins and polystyrene tubes coated with specific antibody has been developed for assaying the relative concentrations of antibodies...Full Text Available

1975-06-01

307

Chromium steel corrosion rates and mechanisms in aqueous nickel chloride at 300C  

International Nuclear Information System (INIS)

Rapid corrosion of PWR steam generator carbon steel support structures and consequential denting of steam generator tubes led to investigation of alternative support designs and materials. In recent designs of steam generators the carbon steel drilled hole tube support plate has been replaced by one of quatrefoil or trefoil shape to minimize the contact area. These plates are now made of more corrosion resistant chromium steel (approx. 12%Cr) to ensure that they are less vulnerable to attack in the event of adverse boiler water chemistry. This study was initiated to examine the corrosion behavior of a range of chromium steels in the acid chloride environments characteristic of tube/support plate crevices under adverse boiler water conditions. Objectives of the study were to: 1) determine the relative susceptibility of candidate tube support plate steels to acid chloride corrosion; 2) investigate the ...

1985-03-01

308

Changing the emphasis at Bruce A  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tube plugging rates have increased markedly at Bruce since the end of the 1980s. A new programme of refurbishment aims to keep the steam generators operating successfully until around 2015. (Author).

1994-01-01

309

Changing the emphasis at Bruce A  

International Nuclear Information System (INIS)

Steam generator tube plugging rates have increased markedly at Bruce since the end of the 1980s. A new programme of refurbishment aims to keep the steam generators operating successfully until around 2015. (Author).

310

Boiler and HRSG tube failures. Lesson 2. Corrosion fatigue  

Energy Technology Data Exchange (ETDEWEB)

Fatigue damage occurs in general when a boiler tube is subject to repeat cyclic or fluctuating loading although the stress produced is below the material yield strength. The types of fatigue damage include, e.g., corrosion, thermal, mechanical, vibration, and creep fatigue. It is important to determine which form of fatigue is active, because measures to avoid repeat failures differ as the case arises. In this lesson, the focus is exclusively on corrosion fatigue. Corrosion fatigue occurs by the combined synergistic actions of cyclic loading and a corrosive environment. It is a discontinuous process with crack initiation and growth during transient periods. The excessive stresses may be caused during boiler operation by the restraint at tube attachments and by load changes (in particular during cold starts or forced cools) or during shutdown or restart of circulation boilers by thermal stratification of water along the tube ...

2009-10-15

311

Astronaut Jeff Williams Answers Your Questions  

National Aeronautics and Space Administration (NASA)

Expedition 22 Commander Jeff Williams, aboard the International Space Station 220 miles above Earth, responds to questions posted on YouTube concerning the station's orientation, life in space and the recent butterfly experiment.

2010-03-10

312

A post-labeling method for multiplexed and multicolored genotyping analysis of SSR, indel and SNP markers in single tube with bar-coded split tag (BStag)  

UK PubMed Central (United Kingdom)

BackgroundGenotyping analysis using capillary DNA sequencing with fluorescently labeled primer pairs obtained by polymerase chain reaction (PCR) is widely used, but is expensive....Full Text Available

313

A heating tube  

Energy Technology Data Exchange (ETDEWEB)

Hollow needles made of an electrically conducting material are attached by hinges in the openings of the perforated end of an insert in order to intensify heat and mass transfer. The free sections of the needles are placed outside the insert, and a wick is placed on the wall of the frame in the condensation area. The wick overlaps the inlet openings of the insert.

1980-09-23

314

A double antibody solid phase assay for DNA autoantibodies for clinical use.  

UK PubMed Central (United Kingdom)

DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available

1976-08-01

315

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

Energy Technology Data Exchange (ETDEWEB)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described ...

2007-07-01

316

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

International Nuclear Information System (INIS)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described in this ...

2007-08-19

317

Nodular fasciitis: correlation of MRI findings and histopathology  

Energy Technology Data Exchange (ETDEWEB)

Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weighted images, high SI on T2-weighted images, and had homogeneous enhancement. One cellular lesion presented with homogeneous, slightly higher SI than muscle on T1-weighted images and ...

2002-03-01

318

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-15

319

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

International Nuclear Information System (INIS)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-01

320

Theoretical investigations of strength of a flexible tube made of NiTi; Festigkeitstheoretische Untersuchungen einer flexiblen Huelse aus NiTi  

Energy Technology Data Exchange (ETDEWEB)

A flexible, steerable tube (distal end) of an endoscope for the application in the laparoscopic surgery has been analyzed by means of the finite-element-method (FEM). The unusual mechanical and thermal features of the used shape memory alloy (SMA) of NiTi were taken in account. The analyses showed that the strains remain in the super-elastic region up to the maximum bending of 90 and no plastic deformations occur. The application of the shape optimization (CAO) made possible finding the optimal structure of the distal end and therefore powerful reducing the maximum strains in the critical regions. (orig.)

2000-04-01

321

Tank of sodium cooled fast reactor  

International Nuclear Information System (INIS)

Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).

322

TVA's program to mitigate steam generator denting at Sequoyah and Watts Bar Nuclear Plants  

International Nuclear Information System (INIS)

TVA is currently engaged in an extensive program to mitigate steam generator tube denting at the Sequoyah Nuclear Plant, which is in commercial operation, and to prevent or minimize the onset of denting at the Watts Bar Nuclear Plant, which is under construction. This paper describes TVA's denting mitigation program, which is primarily feedwater chemistry and system operation improvement, and the effect the changes that have been implemented have had on the incidence as well as the progression rate of steam generator tube denting during the past 220 effective full power days of Sequoyah unit 1 operation.

1983-09-25

323

Process to eliminate the deposits formed in a steam generator of a pressurized water nuclear reactor  

International Nuclear Information System (INIS)

The present process allows to eliminate the corrosion products formed on the tube plates and in the interstices of plate-tube crosspieces of a PWR steam generator in order to avoid a corrosion phenomenon which may cause denting by presence of oxides. The process consists in applying on these oxides at about 50-100 degrees, an aqueous solution containing 6-8% of gluconic acid, 3-5% of citric acid, about 0.5% of a corrosion inhibitor and ammonia until a pH of 3-9.5 is obtained.

1984-04-05

324

Peristaltic flow of a couple stress fluid in an annulus: Application of an endoscope  

Science.gov (United States)

This paper discusses the influence of an endoscope on the peristaltic flow of a couple stress fluid in an annulus under a zero Reynolds number and long wavelength approximation. The inner tube is uniform, rigid, while the outer tube has a sinusoidal wave traveling down its wall. Analytical expressions for the axial velocity, stream function and axial pressure gradient are established. The flow is investigated in a wave frame of reference moving with the velocity of the wave. Numerical calculations are carried out for the pressure rise, frictional forces and trapping. The features of the flow characteristics are analyzed by plotting graphs and discussed in detail.

2008-04-01

325

Operating experience with condenser tubes made from copper alloys and new developments; Betriebserfahrungen mit Kondensatorrohren aus Kupferlegierungen und aktuelle Entwicklungen  

Energy Technology Data Exchange (ETDEWEB)

Copper alloys are a suitable tubing material for turbine condensers and heat exchangers. Due to problems with corrosions copper alloys increasingly are displaced by high-grade steel and titanium. Blockages and surface formation in the pipes, disturbance of the oxide coating formation, erosion and quality faults with the production are the causes for the corrosion. In the contribution under consideration counter measures are designated for the solution of the problems with corrosions. The application limits for different copper alloys are designated. Recommendations for the optimized operation are given.

2008-07-01

326

Microwave heating type evaporator  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To prevent evaporization stills against corrosion due to radioactive liquid wastes. Constitution: Microwaves are supplied from a microwave generator by way of a wave guide tube and through a microwave permeation window to the inside of an evaporatization still. A matching device is attached to the wave guide tube for transmitting the microwaves in order to match the impedance. When the microwaves are supplied to the inside of the evaporization still, radioactive liquid wastes supplied from a liquid feed port by way of a spray tower to the inside of the evaporization still is heated and evaporated by the induction heating of the microwaves. (Seki, T.).

1987-01-22

327

Laboratory robotics projects in the Analytical Development Division at the Savannah River Laboratory  

International Nuclear Information System (INIS)

To encourage the application of robotics technology for routine radiobench applications, a laboratory dedicated to the research and development of contained robotic systems is being constructed. The facility will have several robots located in laminar flow hoods, and the hoods are being designed to allow the possibility for multiple robots to work together. This paper presents both the design features of the hoods and the general layout of the laboratory, and also discusses an application of a robotic system for the routine nuclear counting of gamma tube samples. The gamma tube system is presently operating in one of the routine analysis laboratories. 5 figs.

328

Integrity assessment of pressure tubes for Wolsung unit 2  

Energy Technology Data Exchange (ETDEWEB)

To improve operational safety of the fuel channel for Wolsung units the recommended primary heat transport system (PHTS) operating guidelines were developed, which provides a safe operation window in terms of pressure and temperature to maintain fuel channel integrity, which is similar to pressure-temperature curves used for primary pressure boundary integrity in PWRs and deterministic Leak-Before Break (LBB) analyses were conducted using recent understanding of delayed hydride cracking (DHC) mechanism. In addition, a comparative assessment of LBB analysis was made using the procedures of Fitness For Service Guidelines(FFSG) for pressure tubes rev. 0 and rev. 1.

1997-10-01

329

Implementation and management of Daya Bay Nuclear Power Plant in-core flux thimble tube in-service inspection  

International Nuclear Information System (INIS)

This article discusses the Daya Bay nuclear power plant in-core flux thimble tube in-service inspection method and strategy. High light of the multiple frequency eddy current technology adopted including frequency and probe choice, standard design, data acquisition process are involved. The wear defect-growing trends are studied on base of the history data, which contribute to the in-service inspection strategy decision. (authors)

2003-04-08

330

Hydrodynamics of swirling flow in a circular tube with sudden increase in cross-section and of the flow through a Borda mouthpiece  

Energy Technology Data Exchange (ETDEWEB)

By applying the mass, momentum, and angular momentum conservation laws and the maximum flow rate principle to swirling, effectively inviscid, incompressible flows in a circular tube with a sudden expansion and the direct-flow and reversed-flow Borda mouthpieces the dependence of the flow rate coefficient and mechanical energy losses on the radius ratio and nondimensional circulation is obtained. Several calculating approaches with potential and helical motion are introduced and investigated. In the case of helical motion, as the swirl decreases the axial core of the flow is found to close with a sudden change of the flow parameters.

1994-11-01

331

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

332

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

333

Development of ALLOY 800 for PWR/SG tubings resistant to IGSCC and general corrosion  

Energy Technology Data Exchange (ETDEWEB)

Resistance of ALLOY 800 as a PWR/SG tubings to IGC/IGSCC and Ni, Co release into high temperature water was evaluated as compared with ALLOYs 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made. From the results, ALLOY 800 was evaluated to be the most reliable among the high Ni alloys tested. In addition, the alloy would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti and Nb, and the prior oxidation treatments, respectively. (author).

1989-07-01

334

Detection of EDM defects under Monju support plate using experimental data from remote field eddy current probes and a multi-frequency algorithm  

International Nuclear Information System (INIS)

This paper describes detection of electro-discharged machine (EDM) defects in magnetic steam generator (SG) tubes of Monju fast breeder reactor (FBR). The EDM defects are located under support plate (SP), on the outer tube surface and they are detected by a remote field eddy current probe. Using the experimental measurements and a multi frequency algorithm, the defect signal can be extracted from the SP signal. The parameters of the multi-frequency algorithm were calculated by comparing SP measurements with two-dimensional finite element simulations (FEM). (author)

2006-07-01

335

Design of a tandem accelerator free electron laser  

International Nuclear Information System (INIS)

The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).

336

Design criterion for tubed solar-heated cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiences, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.

1986-07-01

337

Design criterion for tubed solar-heated cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiencies, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.

1986-01-01

338

Corrosion performance of tube support materials  

International Nuclear Information System (INIS)

The problem of denting in steam generators leads to change in the conception of the tube support plates. A new material is now used for this component, a 13% Cr steel, which composition has been adjusted for weldability and mechanical resistance criteria. The geometry of trefoil support plate (TSP) has also been improved, using a broached TSP (quadrifoiled holes) instead of a drilled TSP. Tests have been performed on 13% Cr and C-steel broached TSP, and drilled TSP, to confirm the better resistance to denting of this new configuration.

1985-03-01

339

Comprehensive characterization of fuel, clad and wrapper materials and assemblies for fast reactors - towards design, development and performance  

International Nuclear Information System (INIS)

The paper provides a brief description of the fuel characterization for Fast Breeder Test Reactor (FBTR) and Prototype Fast Breeder Reactor (PFBR). The development and characterization of mechanical properties of Alloy D9 clad and wrapper tubes are discussed. The problems associated with fusion welding of Alloy D9 are outlined. Non-destructive characterization of cladding tubes by optimum encircling eddy current probes, on-line and off-line neural network methods is presented. Both the on-line and off-line neural network methods could readily detect and size defects specified by the designers

2004-01-01

340

BNES materials conference a status review of alloy 800  

International Nuclear Information System (INIS)

Existing applications of Alloy 800 are summarized, with particular reference to its use in various types of reactor. The need for a co-ordinated research and development programme is stressed, and the variables to be explored are outlined. The papers relating to the problem of corrosion and cracking in water and steam are considered. the strength and ductility of Alloy 800 is considered. Finally, sections of the summary deal with the use of Alloy 800 for (a) sodium cooled fast reactor boiler tubes; (b) the high temperature gas cooled reactor; and (c) PWR steam generator tubes. (U.K.).

341

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

342

Application of the porous media model for the LWR process components  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the principles modelling optional boundary ...

2005-07-01

343

Application of neutron radiography to a diagnosis of refrigerator  

International Nuclear Information System (INIS)

A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).

1996-07-01

344

A truly commercial product  

International Nuclear Information System (INIS)

In one of the first uses of high Tc superconductors in an end-use product, Lake Shore Cryotronics and a Swiss lab have developed a liquid nitrogen level sensor using a high Tc thin film. The probe is manufactured using a seamless stainless steel tube with an yttrium-based zirconium oxide flame-sprayed on the tube. A plasma-sprayed superconductor compound is deposited on top of that. The probe is coated with a sealant that protects the superconducting film from the atmosphere. This manufacturing method has yielded an extremely durable product. Unaffected by ice formation and related mechanical problems, the superconducting level sensor can be kept in the dewar for long periods of time.

345

A review of the behaviour of alloy 800 in liquid sodium  

International Nuclear Information System (INIS)

Although there is service experience of Alloy 800 as tubing for superheaters in conventional and nuclear (HTR) power stations and in PWR heat exchangers, there is no corresponding service experience in sodium-cooled fast reactor steam generators. However, some limited experimental studies have been made of corrosion behaviour, and of possible structure modifications and effects on mechanical properties which occur during exposure of this material to a high temperature sodium environment, and these are summarised in the paper. It is concluded that further work needs to be done before Alloy 800 can be confidently endorsed for use as tubing in fast reactor steam generators. (author).

346

A mathematical model for a thermally coupled humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

The humidification?dehumidification process is an interesting technique that has been adapted for water desalination. Previous works experimentally investigated desalination processes in the shell and tube columns, where the humidification and dehumidification were thermally coupled and simultaneously performed at the tube and shell sides, respectively. In this work, a comprehensive steady-state mathematical model was developed for such a humidification?dehumidification desalination process by taking into account the heat and mass balances on both sides of the desalting column, the mass transfer rate at the humidification side, and the heat transfer rate between the dehumidification side and humidification side. Meanwhile, the mass transfer coefficient at the humidification side and the to...

2006-01-01

347

Visual inspection technology of the narrow and small confined area for monitoring feederpipe support of pressure tube in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post-Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And ultrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughly because of narrow and confined accessibility, that is , an inspection space between the pressure tube channels is less than 100 mm and pipes in ...

1999-12-01

348

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

Energy Technology Data Exchange (ETDEWEB)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface ...

1996-01-01

349

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

International Nuclear Information System (INIS)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface ...

1992-01-01

350

Studies on the permeation of hydrogen through steam generator tubes at high temperatures using an electrochemical method  

Energy Technology Data Exchange (ETDEWEB)

The permeation of hydrogen through steam generator tubes at high temperatures ({approx} 300 degrees C) has been studied using an electrochemical technique. With this technique, hydrogen is generated on one side of the tube and monitored on the other side. The time for the hydrogen to reach the other side is used to determine the diffusion coefficient of hydrogen in the tube. Boundary conditions at the entry and exit sides have been investigated separately. Preliminary studies were performed on Stainless Steel 316 and Nickel Alloy 800 to better understand the influence of the solution chemistry on the electrochemical evolution of hydrogen. The surface phenomena effect and the trapping effect are discussed to account for differences observed in the permeation response. The hydrogen permeation through oxides at the exit side has been studied. Two nickel alloys (Alloy 800 and Alloy 600), materials widely used for steam ...

1998-07-01

351

Fatigue behavior of Alloy 690 and Alloy 800 SG tubing at temperatures up to 330{sup o}C in very high cycle fatigue regime  

Energy Technology Data Exchange (ETDEWEB)

During the service in nuclear power plants, steam generator (SG) tubing will suffer from a vibration with a frequency from 30-40 Hz. This means that SG tubing will undergo a very high cycle fatigue process during the design life time (25 years=about 3x10{sup 10}cycles). The material degradation and the very high cycle fatigue life of SG tubing materials due to the vibration are therefore of concern. In this investigation, the fatigue properties of Alloy 690 and Alloy 800 SG tubing in the very high cycle fatigue regime (higher than 10{sup 7} cycles) and strain controlled fatigue at temperatures up to 330{sup o}C have been investigated. The fatigue properties of SG tubing of Alloy 690 are comparable to that of wrought material. The strain controlled fatigue properties of Alloy 690 and Alloy 800 are slightly better at 288{sup o}C than at room temperature (RT). At the stress near the ...

2007-07-01

352

Fatigue behavior of Alloy 690 and Alloy 800 SG tubing at temperatures up to 330"oC in very high cycle fatigue regime  

International Nuclear Information System (INIS)

During the service in nuclear power plants, steam generator (SG) tubing will suffer from a vibration with a frequency from 30-40 Hz. This means that SG tubing will undergo a very high cycle fatigue process during the design life time (25 years=about 3x10"1"0cycles). The material degradation and the very high cycle fatigue life of SG tubing materials due to the vibration are therefore of concern. In this investigation, the fatigue properties of Alloy 690 and Alloy 800 SG tubing in the very high cycle fatigue regime (higher than 10"7 cycles) and strain controlled fatigue at temperatures up to 330"oC have been investigated. The fatigue properties of SG tubing of Alloy 690 are comparable to that of wrought material. The strain controlled fatigue properties of Alloy 690 and Alloy 800 are slightly better at 288"oC than at room temperature (RT). At the stress near the fatigue endurance, ...

2007-08-19

353

Effect of lead and silicon on localized corrosion of Alloy 800 in steam generator crevice environments  

Energy Technology Data Exchange (ETDEWEB)

The Alloy 800 tubes used in CANDU 6 steam generators have not experienced significant corrosion damage to date, which may be attributed to successful water chemistry control strategies. However, it is known that Alloy 800, like other steam generator (SG) tubing materials, is not immune to corrosion, especially pitting, under some plausible but off-specification operating scenarios. Electrochemical measurements provide information on corrosion susceptibility and rate, which are known to be a function of water chemistry. Using laboratory data in combination with chemistry monitoring and diagnostic software it is possible to assess the impact of plant operating conditions on SG tube corrosion for plant life management (PLIM). In this context, this paper discusses the results of electrochemical measurements made to elucidate the corrosion behaviour of Alloy 800 SG tubes under conditions simulating those ...

2001-09-01

354

EDF approach on OD corrosion of SG tubes  

Energy Technology Data Exchange (ETDEWEB)

The secondary side corrosion of steam generator tubes is the main degradation of components in operating power plants, strongly impacted by chemistry. This is why EDF has largely studied the chemical parameters in its 56 PWRs which might influence corrosion development. The results of 168 hideout returns of chemical species performed on the French plants allowed to draw conclusions on where chemical species are likely to concentrate in steam generators and on the influence of several contaminants on corrosion processes: sodium, chloride, phosphate, organic compounds, etc... Based on laboratory studies and plants feedback, new chemistry specifications were established and are now applied to EDF units to minimize corrosion and operating costs and to provide a good availability while maintaining an excellent safety. Boric acid is added in the secondary water of the 10 oldest units with Inconel 600 MA tubing, highly sensitive to intergranular ...

1998-12-31

355

Development of a numerical methodology to simulate the roller expansion forming process  

International Nuclear Information System (INIS)

A distinguishing design feature of CANDU nuclear reactors is the use of horizontal fuel channels housed in a horizontal vessel called a calandria, which is made of stainless steel 304L. Each channel consists of a Zr-2.5%Nb alloy pressure tube and an externally concentric Zr-2 calandria tube. The calandria tubes are joined to the end plates (tubesheets) of the calandria vessel by joints formed by roller expansion. The bores in the tubesheets are grooved. Roller expanded joints provide a cost effective means of joining dissimilar materials, require minimal space and no maintenance. The quality of these roller expanded joints is important from a sealing, strength and stress corrosion point of view. The roller expansion process consists of expanding the calandria tubes to deform them plastically against the bores and into the grooves of the tubesheets. Therefore, understanding the effect of the number, ...

2006-04-03

356

Delayed Hydride Cracking Mechanism in Zirconium Alloys and Technical Requirements for In-Service Evaluation of Zr-2.5Nb Tubes with Flaws  

International Nuclear Information System (INIS)

In association with periodic inspection of CANDU nuclear power plant components, Canadian Standards Association issued CSA N285.8 in 2005 as technical requirements for in-service evaluation of zirconium alloy pressure tubes in CANDU reactors. This first version, CSA N285.8 involves procedures for, firstly, the evaluation of pressure tube flaws, secondly, the evaluation of pressure tube to calandria tube contact and, thirdly, the assessment of a reactor core, and material properties and derived quantities. The evaluation of pressure tube flaws includes delayed hydride cracking evaluation the procedures of which are stipulated based on the existing delayed hydride cracking models. For example, the evaluation of flaw-tip hydride precipitation during reactor cooldown involves a procedure to calculate the equilibrium hydrogen equivalent concentration in solution at the flaw tip, Htipas ...

2007-05-10

357

Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests  

Energy Technology Data Exchange (ETDEWEB)

The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, ...

1998-10-01

358

Heat transfer augmentation of a circular pipe flow using nano-particle layers  

International Nuclear Information System (INIS)

For the advanced fusion reactor FFHR2 (Force Free Helical Reactor) that has been proposed by NIFS, molten salt Flibe (LiF:BeF2=64:36) breeder blanket system is selected because of Flibe's features such as chemical stability, low-pressure operation and low electric conductivity. The Flibe is however high Prandtl number fluid since it has high viscosity and low thermal conductivity. Therefore its heat transfer performance is low compared with liquid Li or Pb-Li. In addition to heat removal of 1MW/m2 on the first wall, electrolysis of molten salt due to MHD effect will take place under high flow rate condition. This indicates that heat transfer enhancement under low flow rate is essential for the Flibe blanket system. In our laboratory, heat transfer characteristics of molten salt HTS (KNO3:NaNO2:NaNO3=53:40:7), have been evaluated, which is used as a simulant fluid of Flibe from the points of view of Be's toxicity and similar Prandtl number. In this paper, we adopt nano-particle layer ...

2007-10-05

359

Alloy 800 SG tubing: current status and future challenges  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio ({>=}12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those ...

2007-07-01

360

Alloy 800 SG tubing: current status and future challenges  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio (#>=#12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those that ...

2007-08-19

361

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have shown a clear dominance ...

2002-07-01

362

3D transient calculations of PGV-1000 based on TRAC  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: During calculations of SAR accidents and transients it is necessary to perform steam generator simulation. Best accuracy is 3D transient calculations presented in report. Main outcomes of work was next: 1. There was shown by analysis the applicability of code TRAC (Los-Alamos laboratory) for thermal - hydraulic calculations of horizontal steam generator PGV-1000M. Special nodalization scheme was developed for it purposes. 2. Validation and selection of thermal-hydraulic correlations for improvement of using the code at calculation PGV-1000M were performed. As result Labuntsov formula is recommended for horizontal SG. 3. Calculations of nominal mode operation of PGV-1000M for cross-verification with code STEG (Electrogorsk Research and Engineering Center EREC) during its verification were performed. Solution by TRAC was obtained for transient problem after stabilization time. 4. Development of dynamic SG model as conjugate problem (thermal hydraulic of ...

2005-07-01

363

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...

1998-02-01

364

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

International Nuclear Information System (INIS)

Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam-water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two-phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 MW TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...

1999-11-03

365

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

International Nuclear Information System (INIS)

Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...

1998-03-16

366

Steam generator access modification and waterlance cleaning for Wolsong and other nuclear plants  

International Nuclear Information System (INIS)

Steam generators for nuclear plants require access to the primary and secondary side for various inspection, cleaning and repair procedures and upon achieving access various inspection and cleaning tasks must be carried out. Steam generators currently at manufacture are therefore provided with; primary side access via the primary manways, steam drum access via the steam drum manway, U-bend region access via the secondary manway and drum-internals access passages, tubesheet secondary side access via tubesheet level inspection ports and tube support plate access via tube support level access ports. Many CANDU steam generators were built with only primary and drum manways and either no tubesheet ports or ports which were located ineffectively. The steam generators at Wolsong 1 were built with secondary side inspection ports that provided only limited access away from the no-tube-lane. In addition they have very difficult ...

2002-05-05

367

Risk assessment of severe accident-induced steam generator tube rupture  

Energy Technology Data Exchange (ETDEWEB)

This report describes the basis, results, and related risk implications of an analysis performed by an ad hoc working group of the U.S. Nuclear Regulatory Commission (NRC) to assess the containment bypass potential attributable to steam generator tube rupture (SGTR) induced by severe accident conditions. The SGTR Severe Accident Working Group, comprised of staff members from the NRC`s Offices of Nuclear Reactor Regulation (NRR) and Nuclear Regulatory Research (RES), undertook the analysis beginning in December 1995 to support a proposed steam generator integrity rule. The work drew upon previous risk and thermal-hydraulic analyses of core damage sequences, with a focus on the Surry plant as a representative example. This analysis yielded new results, however, derived by predicting thermal-hydraulic conditions of selected severe accident scenarios using the SCDAP/RELAP5 computer code, flawed tube failure modeling, and tube ...

1998-03-01

368

Nature Of Tube Degradation In Horizontal Steam Generators  

Energy Technology Data Exchange (ETDEWEB)

Nature of tube degradation was studied in support of horizontal steam generator lifetime calculations. Experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K(ISCC), and the crack growth rate were made to predict evolution of damage in tube walls. Experimental results were compared with in-service inspections experience. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that material of SG (steam generator) tubes ...

2002-07-01

369

Nature Of Tube Degradation In Horizontal Steam Generators  

International Nuclear Information System (INIS)

Nature of tube degradation was studied in support of horizontal steam generator lifetime calculations. Experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K(ISCC), and the crack growth rate were made to predict evolution of damage in tube walls. Experimental results were compared with in-service inspections experience. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that material of SG (steam generator) tubes ...

2002-09-23

370

Extreme embrittlement of austenitic stainless steel irradiated to 75--81 dpa at 335--360 C  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the results of an experiment conducted in the BN-350 fast reactor in Kazakhstan that involved the irradiation of argon-pressurized thin-walled tubes (0--2000 MPa hoop stress) constructed from Fe-16Cr-15Ni-3Mo-Nb stabilized steel in contact with the sodium coolant, which enters the reactor at {approximately}270 C. Tubes in the annealed condition reached 75 dpa at 335 C, and another set in the 20% cold-worked condition reached 81 dpa at 360 C. Upon disassembly all tubes, except those in the stress-free condition, were found to have failed in an extremely brittle fashion. The stress-free tubes exhibited diameter changes that imply swelling levels ranging from 9 to 16%. It is expected that stress-enhancement of swelling induced even larger swelling levels in the stressed tubes. The embrittlement is explained in terms of the sensitivity of the swelling regime to ...

1998-03-01

371

Experiences in radioactive gaseous effluent management in JAERI  

International Nuclear Information System (INIS)

In the Japan Research Reactor-II (JRR-2), the main source of _4_1Ar generation is the exhaust air from the horizontal experimental holes and the pneumatic tubes. For the horizontal experimental holes, the flow of exhaust air through the holes was decreased by improving the airtightness, and a decay duct of capacity 2.4 m_3 was installed in the middle of the exhaust line. In consequence, the release rate of _4_1Ar was reduced by 6-8%. For the pneumatic tubes, a mechanical shutter was installed in the tube. The shutter stops the exhaust air flow, except when the pneumatic tube is used. Prior to the use, the activated air in the tube is led to a decay tank. As a result, the _4_1Ar release rate was reduced by 10-20%. By the above means, the yearly exposure at the site boundary was reduced to 0.36 mR from 2.6 mR. In Hot Laboratory for metallurgical examination of spent fuel, the exhaust ...

1983-05-01

372

Evaluation of new corrosion resistant superheater tubings in high efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

In order to develop new corrosion resistant superheater tubes capable of functioning efficiency under temperature and pressure conditions of 500 C and 100 ata used in high efficient waste-to-energy (WTE) plants, field corrosion tests were conducted on eight single tube materials and two welded overlay materials at metal temperatures of 450 C and 550 C for 700 and 3,000 hours, respectively, in three typical japanese waste incineration plants. The test results indicate that austenitic alloys containing higher concentrations of [Cr + Ni + Mo] show excellent corrosion resistant properties and new alloys of JHN24 and HR30M have good corrosion resistance. The different corrosion rate found for each of the three plants could be explained by differences in the severity of corrosion factors, such as, gas temperature, concentration of molten salts due to Cl content of deposits, and heavy metal [ZnO + PbO] content etc. It was also confirmed that the ...

1997-08-01

373

Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66{approx}8.91 x 1025 n/m{sup 2}) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4{approx}6 times faster DHC velocity(5.298E-0.8{approx}7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was seen DHC fracture ...

2003-10-01

374

Effect of neutron irradiation on DHC velocity at CANDU Zr-2.5Nb pressure tube  

International Nuclear Information System (INIS)

The objective of this study is to evaluate the lifetime of Zr-2.5Nb pressure tube at Wolsung Unit-1. The testing materials (Effective full power year: 9.3 year, Accumulated nuetron fluence: 7.66#approx#8.91 x 1025 n/m"2) were sampled from M-11 tube at various position(inlet, middle and outlet). The cutting was carried out at hot cell to fabricate CT(Compact tension) specimen with 48 ppm hydrogen content. In the result of DHC test, irradiation-damaged specimen showed 4#approx#6 times faster DHC velocity(5.298E-0.8#approx#7.039E-8 m/s: 182 .deg. C) than non-irradiated specimen. These DHCV results also show slight faster than one of specimen from Pickering plant (average DHCV: 4.5E-8 m/s: 182 .Deg C). This faster DHCV can be explained with the fact that Wolsung Unit-1 have been operated in a severe conditions(higher cooling water temperature, high power and efficiency) than Pickering one. The striation spacing which was seen DHC fracture surface ...

2003-10-01

375

Development of video probe system for inspection of feeder pipe support in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post- Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And untrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughlv because of narrow and confined accessibility, that is, an inspection space between the pressure tube channels is less than 100mm and pipes in feederpipe support area are congested. And also, workers involved in inspecting ...

2000-07-01

376

Comparison of steam-generator liquid holdup and core uncovery in two facilities of differing scale  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on Run SB-CL-05, a test similar to Semiscale Run S-UT-8. The test results show that the core was uncovered briefly during the accident and that the rods overheated at certain core locations. Liquid holdup on the upflow side of the steam-generator tubes was observed. After the loop seal cleared, the core refilled and the rods cooled. These behaviors were similar to those observed in the Semiscale run. The Large-Scale Test Facility (LSTF) Run SB-CL-06 is a counterpart test to Semiscale Run S-LH-01. The comparison of the results of both tests shows similar phenomena. The similarity of phenomena in these two facilities build confidence that these results can be expected to occur in a PWR. Similar holdup has now been observed in the 6 tubes of Semiscale and in the 141 tubes of LSTF. It is now more believable that holdup may occur in a full-scale steam generator with 3000 or more tubes. ...

1987-01-01

377

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results of void fraction in ...

1993-06-01

378

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (inner diameter; 4.08mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3 M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results of void ...

1994-07-01

379

Application of neutron radiography to visualization and void fraction measurement of air-water two-phase flow in a small diameter tube  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the feasibility of visualization and void fraction measurement of air-water two-phase flow in a small diameter tube (I.D.: 4.08 mm) by using the real-time neutron radiography and image processing techniques. Video images of two-phase flow were taken by using the real-time neutron radiography system (thermal neutron radiography facility No.2) installed at the Japan Research Reactor 3M of the Japan Atomic Energy Research Institute. The shape of bubbles and its moving behavior were clearly observed from the video images. The image corrections for dark current, shading, field intensity fluctuation and electrical system drift were examined in order to measure the void fraction from the video images. Though, generally speaking, the effect of the scattered neutron could not be ignored for quantification of the images taken by the neutron radiography, the scattered neutron could not affect the final results of void fraction in ...

1993-01-01

380

Weldability of high strength Ni-based alloy USC141 as boiler tube for 700 C USC plant  

Energy Technology Data Exchange (ETDEWEB)

Recently the increase of steam temperature and pressure of power plant is required to enhance the thermal efficiency and reduce the CO{sub 2} emission. For the application to advanced USC (Ultra Super Critical) boiler with steam temperature around 700 C, the application of Ni-based alloy such as Alloy617 will be necessary. A new Ni-based alloy USC141 (20Cr-10Mo-2Ti-Al-bal.Ni) with excellent creep rupture strength and low thermal expansion has been developed by Hitachi Ltd. and Hitachi Metals Ltd. as the candidate material for 700 C USC turbine components. In present work, to investigate the possibility for boiler tube application of USC141, its weldability and high temperature strength properties were experimentally examined. The tested material as solution-treated condition shows higher creep rupture strength than that of Alloy617. GTAW (Gas Tungsten Arc Welding) trials of tubular specimen using NIMONIC263 filler wire were conducted successfully and the creep ...

2007-07-01

381

Thermal analysis of spent fuel in shuttle station during dry transfer under abnormal cooling conditions for TAPS - 4  

International Nuclear Information System (INIS)

A pair of bundles is placed in a shuttle tube, which is enclosed by a carriage tube kept inside the Shuttle Transfer Station (STS). It takes about 90 minutes for the spent fuel bundles to travel from the reactor channel to Transfer Magazine (TM). Subsequently, the dry transfer operation takes about 4 minutes. An emergency air cooling flow rate of 600 m3/hr is supplied to cool the spent fuel bundles after they reach the STS, following lapse of 4 minutes of spent fuel dry transfer, in case the bundles are not submerged in the light water in STS. A thermal and hydraulic safety analysis has been done to estimate the maximum sheath temperature, if the spent fuel bundles are stuck at a location of 30 mm below the normal location aligned to the TM port. This position of the spent fuel will have least cooling from the emergency cooling airflow. At the same time, the shuttle tube carrying the spent fuel bundle is just above the ...

2006-11-13

382

Theoretical simulation of SDS - 2 actuation in 540 MWe PHWR  

International Nuclear Information System (INIS)

The 540 MWe PHWR has two fully independent shutdown systems. The first shutdown system (SDS-1) comprises of 28 spring assisted, vertical gravity drop shut-off rods, each consisting of a cadmium absorber sandwiched between stainless steel tubes. The second shutdown system (SDS-2) constitutes six poison tanks connected to respective zircaloy injection tubes. This system is capable of high speed injection of gadolinium nitrate solution (in D2O) into the moderator through these tubes. Theoretical estimation was carried out at different injection pressures and different concentration of gadolinium nitrate solution to arrive at the limiting value of these parameters from reactivity consideration point of view. The plant measurements of SDS-2 actuations at 60 and 80 Kg/cm2 pressure of helium was used to validate and upgrade the estimation model. The paper gives the details of the validation details of SDS-2 actuation. (author)

2006-11-13

383

TheU-Tube: A Novel System for Acquiring Borehole Fluid Samplesfrom a Deep Geologic CO2 Sequestration Experiment  

Energy Technology Data Exchange (ETDEWEB)

A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass spectrometer provided real-time gas ...

2005-03-17

384

Separation of Minor Actinides and Lanthanides with Carbon Nano-materials  

Energy Technology Data Exchange (ETDEWEB)

Recently we have found that carbon nano-materials have ability to recognize softer actinides(III). In this presentation, separation of americium(III) from lanthanides(III) by chromatography with carbon nano-materials, such as carbon nano-tubes and graphite, has been investigated by batch adsorption experiments and chromatography. The separation factor (SF) between americium(III) and lanthanide(III) was about 2 in the range of pH from 1 to 4 by using carbon nano-tube, graphite and activated charcoal. The separation factor depended on the diameter of carbon nano-tubes. Smaller one, 3-20 nm diameter, showed the best selectivity for americium(III), which separation factor was about 2.0, although larger one, 40-70 nm, showed almost no selectivity. The same behavior has been observed by using graphite powder and activated charcoal although acid- or alkali pretreated activated charcoal which generally has acidic functional group ...

2009-06-15

385

Relaxation and corrosion resistance of alloy 800 used for steam generator tubes of ship borne boilers  

Energy Technology Data Exchange (ETDEWEB)

The INCO ``INCOLOY 800`` trademark groups the Fe-Cr-Ni alloys containing 30 to 35% nickel, 19 to 23% chromium, 0,15 to 0,60% aluminium, 0,15 to 0,60% titanium and less than 0,10% carbon contents, used as construction materials for condenser and heat exchanger tubes. In parallel with water chemistry control and studies aimed at reducing the residual stresses resulting from tube expansion, studies have been conducted to a better understanding of this alloy, its metallurgy and its corrosion behaviour under accurately defined fabrication and heat treatment conditions. The purpose of this paper is to present the results of a behaviour study of INDRET alloy 800 concerning isothermal relaxation and effects of the said relaxation heat treatments on alloy microstructure studied with a transmission electron-chemical method to determine the sensitiveness to intergranular corrosion, and by electrochemistry in pressurized hot water. (authors). 4 figs., 5 ...

1994-12-31

386

Reducing the effect of penstock pressure pulsations on hydro electric plant power system stabilizer signals  

Energy Technology Data Exchange (ETDEWEB)

A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with generator power as the feedback signal and the ...

1993-12-01

387

Reactor fuel cladding tube with excellent corrosion resistance and method of manufacturing the same  

International Nuclear Information System (INIS)

The present invention provides a fuel cladding tube having an excellent corrosion resistance and thus a long life, and a suitable manufacturing method therefor. Namely, in the fuel cladding tube, the outer circumference of an inner layer made of a zirconium base alloy is coated with an outer layer made of a metal more corrosion resistant than the zirconium base alloy. Ti or a titanium alloy is suitable for the corrosion resistant metal. In addition, the outer layer can be coated by a method such as vapor deposition or plating, not limited to joining of the inner layer material and the outer layer material. Specifically, a composite material having an inner layer made of a zirconium alloy coated by the outer material made of a titanium alloy is applied with hot fabrication at a temperature within a range of from 500 to 850degC and at a fabrication rate of not less than 5%. The fabrication method includes any of extrusion, rolling, drawing, and ...

1993-07-14

388

Rationale for chemical control of feedwater and boiler water. Volume 1. Concentration models. Final report  

Science.gov (United States)

Operating PWR units in the USA have experienced very severe corrosion of the tube support plate at the crevice between the tube and the support. This results in distortion of the plate and crushing of the tube (denting). The first task of this project required that currently available computational methods to estimate the pH attained by concentrating boiler water under various fault conditions such as condenser leakage of river waters and faulty operation of condensate polishing plant. Particular attention has been paid to systems in which sulfate predominates. In the second task, the mechanisms are discussed by which solutions become concentrated in porous deposits on a boiling heat transfer surface. It is concluded that more experimental data are needed to test the validity of existing models. High solution concentrations in the deposit may occur at a heat flux close to the critical value for drying out the base of the ...

1984-01-01

389

Plasma chemistry in wire chambers  

Energy Technology Data Exchange (ETDEWEB)

The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of ...

1990-05-01

390

Optimisation of solar-heated cavity receivers with paraboloid collectors. Optimierung von solar beheizten Hohlraumstrahlungsempfaengern mit Paraboloidkollektoren  

Energy Technology Data Exchange (ETDEWEB)

The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be derived from the useful heat which ...

1984-01-01

391

Modeling of boiling- and tow-phase flow in offset-strip-fin heat-exchanger geometries  

Energy Technology Data Exchange (ETDEWEB)

The two-phase heat-transfer and pressure-drop characteristics of offset-strip-fin heat-exchanger geometries are examined using both experimental and analytical modeling techniques. Newly-obtained boiling-flow heat-transfer data are presented for two large-scale offset fin geometries at low-to-moderate wall-superheat conditions. Data for which nucleate boiling appeared to be completely suppressed were analyzed together with similar results for other offset fin surfaces to study the effects of channel dimensions on the convective evaporation component of the local heat transfer coefficient. Although these data were found to be well correlated in terms of modified forms of the F and Martinelli parameters used in previous studies of round-tube flows, a single F-factor correlation valid for all combinations of fin and channel dimensions did not appear to exist. The two-phase pressure-drop characteristics of offset-fin surfaces were found to be much different than those ...

1988-01-01

392

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same elevation). Previous ...

1993-01-01

393

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

International Nuclear Information System (INIS)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube's inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 ...

1993-07-06

394

Heat transfer augmentation in a heat exchanger tube using a baffle  

International Nuclear Information System (INIS)

Heat transfer enhancement in a heat exchanger tube by installing a baffle is reported. The effect of baffle size and orientation on the heat transfer enhancement was studied in detail. Three different baffle arrangements were considered. The results show that for the vertical baffle, an increase in the baffle height causes a substantial increase in the Nusselt number but the pressure loss is also very significant. For the inclined baffles, the results show that the Nusselt number enhancement is almost independent of the baffle inclination angle, with the maximum and average Nusselt number 120% and 70% higher than that for the case of no baffle, respectively. For a given baffle geometry, the Nusselt number enhancement is increased by more than a factor of two as the Reynolds number decreased from 20,000 to 5000. Simulations were conducted by introducing another baffle to enhance heat transfer. The results show that the average Nusselt number for the two baffles case ...

2007-04-01

395

Heat transfer augmentation for external ice-on-tube TES systems using porous copper mesh to increase volumetric ice production  

Energy Technology Data Exchange (ETDEWEB)

Substantial thermal performance improvement in ice-on-tube cold thermal energy storage systems (TES) is possible by making use of porous copper mesh as a Heat Conducting Enhancement Device (HCED). HCEDs are inexpensive heat transfer augmentation devices that can result in faster rate of ice growth and larger final steady state ice build volume by reducing the controlling thermal conduction resistance of the ice layer. This improves the competitiveness of external ice-on-tube systems as compared to other TES systems, such as dynamic ice harvesters and static internal melt systems. In this study the amount of ice growth enhancement is predicted theoretically, by performing simplified 1-D calculations, and is then validated in the laboratory through carefully controlled experiments. This study shows that ice volume increase between 50 and 90% is possible by using HCEDs of the type tested. (author)

2006-09-15

396

Flow regime transition criteria for upward two-phase flow in vertical tubes  

Energy Technology Data Exchange (ETDEWEB)

Traditional two-phase flow-regime criteria based on the gas and liquid superficial velocities may not be suitable to the analyses of rapid transient or entrance flows by the two-fluid model. Under these conditions, it is postulated that direct geometrical parameters such as the void fraction are conceptually simpler and therefore more reliable parameters to be used in flow-regime criteria than the traditional parameters. From this point of view, new flow-regime criteria for upward gas-liquid flow in vertical tubes have been developed considering the mechanisms of flow-regime transitions. These new criteria can be compared to existing criteria and experimental data under steady-state and fully developed flow conditions by using relative velocity correlations. The criteria showed reasonable agreements with the existing data for atmospheric air-water flows. Further comparisons with data for steam-water in round tubes and a rectangular channel at ...

1984-05-01

397

Flow regime transition criteria for upward two-phase flow in vertical tubes  

International Nuclear Information System (INIS)

Traditional two-phase flow-regime criteria based on the gas and liquid superficial velocities may not be suitable to the analyses of rapid transient or entrance flows by the two-fluid model. Under these conditions, it is postulated that direct geometrical parameters such as the void fraction are conceptually simpler and therefore more reliable parameters to be used in flow-regime criteria than the traditional parameters. From this point of view, new flow-regime criteria for upward gas-liquid flow in vertical tubes have been developed considering the mechanisms of flow-regime transitions. These new criteria can be compared to existing criteria and experimental data under steady-state and fully developed flow conditions by using relative velocity correlations. The criteria showed reasonable agreements with the existing data for atmospheric air-water flows. Further comparisons with data for steam-water in round tubes and a rectangular channel at ...

1984-01-01

398

Externally fired combined cycle demonstration  

Energy Technology Data Exchange (ETDEWEB)

Externally Fired Combined Cycles (EFCCs) can increase the amount of electricity produced from ash bearing fuels up to 40%, with overall powerplant efficiencies in excess of 45%. Achieving such high efficiencies requires high temperature-high pressure air heaters capable of driving modern gas turbines from gas streams containing the products of coal combustion. A pilot plant has been constructed in Kennebunk, Maine to provide proof of concept and evaluation of system components. Tests using pulverized Western Pennsylvania bituminous coal have been carried out since April, 1995. The ceramic air heater extracts energy from the products of coal combustion to power a gas turbine. This air heater has operated at gas inlet temperatures over 1,095 C and pressures over 7.0 atm without damage to the ceramic tube string components. Stable gas turbine operation has been achieved with energy input from the air heater and a supplementary gas fired combustor. Efforts are underway ...

1995-11-01

399

Experimental study and performance evaluation of convective heat transfer augmentation with coiled wire inserts  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of forced convection heat transfer at the inner tube wall of a double pipe heat exchanger with coiled wire inserts as heat transfer augmentation devices was performed over a turbulent flow region. The test results from twelve augmented tubes with inserts of different combinations of wire diameters (0.813, 1.016 and 1.575 mm) and pitches (2.82, 3.63, 5.08 and 8.47 mm) indicate that the turbulence promoters studied improve heat transfer by a factor of 1.4 to 2.24 compared with a smooth tube, although at a cost of 10-30 times increase in friction factor. A formula for presenting dimensionless exergy losses in a tubular heat exchanger is derived first and then the thermohydrodynamic optimum instead of economic optimum is found by minimizing the exergy losses in the system. From the heat transfer improvement number defined, it is observed that coiled wire turbulence promoters are more effective at Reynolds ...

1992-12-01

400

Experimental studies on heat transfer and friction factor characteristics of laminar flow through a circular tube fitted with regularly spaced helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation of heat transfer and friction factor characteristics of circular tube fitted with full-length helical screw element of different twist ratio, and helical screw inserts with spacer length 100, 200, 300 and 400mm have been studied with uniform heat flux under laminar flow condition. The experimental data obtained are verified with those obtained from plain tube published data. The effect of spacer length on heat transfer augmentation and friction factor, and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The decrease in Nusselt number for the helical twist with spacer length is within 10% for each subsequent 100mm increase in spacer length. The decrease in friction factor is nearly two times lower than the full length helical twist at low Reynolds number, and four times lower than the full length helical twist at high Reynolds number for all twist ratio. The ...

2007-02-15

401

Experimental analysis of thermal performance of flat plate and evacuated tube solar collectors in stationary standard and daily conditions  

Science.gov (United States)

New comparative tests on two different types of solar collectors are presented in this paper. A standard glazed flat plate collector and an evacuated tube collector are installed in parallel and tested at the same working conditions; the evacuated collector is a direct flow through type with external compound parabolic concentrator (CPC) reflectors. Efficiency in steady-state and quasi-dynamic conditions is measured following the standard and it is compared with the input/output curves measured for the whole day. The first purpose of the present work is the comparison of results in steady-state and quasi-dynamic test methods both for flat plate and evacuated tube collectors. Besides this, the objective is to characterize and to compare the daily energy performance of these two types of collectors. An effective mean for describing and analyzing the daily performance is the so called input/output diagram, in which the collected solar energy is ...

2010-08-15

402

Empirically derived predicators of natural gas flame lengths in circular tubes  

Energy Technology Data Exchange (ETDEWEB)

Flame lengths inside circular tubes, using an (in-shot) atmospheric burner design commonly found in gas-fired residential furnaces were visually observed for natural gas and air under various operating conditions. The flame length data were reduced into dimensionless flame lengths, which were shown to be linearly proportional to the Peclet number of the fuel and air mixture. The dimensionless flame length dependence reported does not scale according to the classical flame models: pre-mixed (laminar) flame or diffusion flame. Instead, the flame length dependence was found to scale with the fuel burn speed, gas/mixture properties (evaluated at the adiabatic flame temperature), and flow parameters. Currently, this is the only flame length study available for the standard atmospheric burner designs commonly used in residential heating products. The results and data reduction provide an easy method to compute flame length penetrations inside circular ...

2000-07-01

403

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants; Traitement des signaux de courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostics system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1991-07-01

404

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants. Traitement des signaux courants de Foucault pour le controle des tubes de generateurs de vapeur dans les centrales nucleaires REP  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

405

Design of APhF-IH Linac for a Compact Medical Accelerator  

CERN Document Server

The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a constant voltage ...

2003-01-01

406

Design and strength evaluation of structural joint made by electro-magnetic forming (EMF)  

International Nuclear Information System (INIS)

Recently, weight reduction of vehicles has been of great interest, and consequently, the use of low-density materials in the automotive industry is increasing every year. Materials should not be substituted such a way that material of component parts is simply changed because there is a problem in achieving stiffness and strength. To achieve these requirements, the automobile should be redesigned totally. Aluminum spaceframe is rapidly being adopted as a body structure for accommodating lightness, stiffness and strength requirement. In aluminum spaceframe manufacturing, it is often required to join aluminum tube. But there are few suitable methods for joining aluminum tube, so that much interest has been focused on testing suitable joining methods. Joining by electromagnetic forming(EMF) can be useful method in joining aluminum tube, which offers some advantages compared with the conventional joining method. In this paper, ...

2004-06-10

407

Design and part-load behavior of a receiver for a solar-heated gas turbine with a parabolic dish collector  

Energy Technology Data Exchange (ETDEWEB)

The present paper deals with the conversion of solar energy in a gas turbine plant with a parabolic dish collector. Particular consideration is devoted to the thermodynamic and mechanical design and partload behavior of the receiver. The incident sunlight is focussed by the parabolic dish and then beamed into the cavity receiver. Here the working medium of the gas turbine flows through tubes and is heated up to the receiver outlet temperature. The task of the receiver is to transfer the radiated energy as efficiently as possible to the working medium. Furthermore the required heating surface should be small as possible i.e. optimum use must be made of the tube material with respect to its state of stress. It is shown which geometric and thermodynamic plant parameters influence these two design criteria. An optimum receiver design is presented on the basis of the results thus obtained. Finally, the variations in receiver efficiency and ...

1984-06-01

408

Corrosion resistant coatings for silicon carbide heat exchanger tubes -- Volume 3. Final report  

Energy Technology Data Exchange (ETDEWEB)

The development of a silicon carbide (SiC) heat exchanger is a critical step in the development of the Externally-Fired Combined Cycle (EFCC) power system. SiC is the only material that provides the necessary combination of resistance to creep, thermal shock, and oxidation. While the SiC structure materials provide the thermomechanical and thermophysical properties needed for an efficient system, the mechanical properties of the SiC tubes are severely degraded through corrosion by the coal combustion products. To obtain the necessary service life of thousands of hours at temperature, a protective coating is needed that is stable with both the SiC tube and the coal combustion products, resists erosion from the particle laden gas stream, is thermal shock resistant, adheres to SiC during repeated thermal shocks (start-up, process upsets, shut-down), and allows the EFCC system to be cost competitive. This demanding set of technical performance and ...

1996-06-07

409

Corrosion of support materials  

International Nuclear Information System (INIS)

Results from a heavily fouled 19 tube C-E model boiler test to investigate the potential for egg crate corrosion in aggressively fouled AVT chemistry are reported. Substantial support plate and egg crate corrosion was produced in this test. Carbon steel drilled support plates exhibited extensive denting which resulted in flow hole ligament cracking. Corrosion of the carbon steel egg crate, through-wall at areas of tube contact, resulted in denting of the Alloy 600 heat transfer tubes. Corrosion performance of the 409 stainless steel egg crate was improved compared to the carbon steel egg crate although localized through-wall corrosion was noted. The results from the above test and previously reported tests were compared based on the following simplifying assumptions: maximum dent size and/or corrosion penetrations utilized, average bulk water chloride concentrations, pilling bedworth ratios, pot and model boilers data are ...

1985-03-01

410

Comparative performance of two types of evacuated tube solar collectors in a residential heating and cooling system. The progress report  

Science.gov (United States)

Two types of evacuated tube solar collectors have been operated in space heating, cooling and domestic hot water heating systems in Colorado State University Solar House I. An experimental collector from Corning Glass Works supplied heat to the system from January 1977 through February 1978, and an experimental collector from Philips Research Laboratory, Aachen, which is currently in use, has been operating since August 1978. A flat absorber plate inside a single-walled glass tube is used in the Corning design, whereas heat is conducted through a single glass wall to an external heat exchanger plate in the Philips collector. In comparison with conventional flat-plate collectors, both types show reduced heat losses and improved efficiency. For space heating and hot water supply in winter, the solar delivery efficiency of the Corning collector ranged from 49% to 60% of the incident solar energy. The portion of the space heating and domestic hot ...

1979-01-01

411

Carbon steel corrosion rates and mechanisms in aqueous nickel chloride at 300C  

International Nuclear Information System (INIS)

Rapid corrosion of PWR steam generator carbon steel support structures and consequential denting of steam generator tubes led to considerable investigation of the mechanism of corrosion and for palliatives. The basic mechanism is now fairly well understood. Chloride present in the boiler feedwater from condenser leakage is concentrated in the support plate crevice as a result of the superheat present. This leads to the formation of a low pH acid ferrous chloride environment either through the hydrolysis of a weak base chloride such as MgCl_2 or the combined action of a neutral chloride with an oxidizing agent. Rapid attack of the carbon steel ensues with the Fe_3O_4 corrosion product forming at the metal/oxide interface. This oxide has a volume approximately twice that of the steel consumed and thus eventually fills the crevice between the tube and the support plate. Oxide growth continues leading to compression of the Alloy 600 primary ...

1985-03-01

412

Applicability of chemical cleaning process to steam generator secondary side, (4). Comprehensive applicability evaluation of chemical cleaning and its effect on integrity of other structural materials other than steam generator tubes  

International Nuclear Information System (INIS)

The application of chemical cleaning for dissolving and removing scale and sludge is being planned in the Japanese pressurized water reactor (PWR) plant in order to maintain high heat transfer performance and to prevent steam generator (SG) tube degradation. In this paper, the effectiveness of the Electric Power Research Institute (EPRI) and German Kraftwerk Union (KWU) processes on the integrity of structural materials other than SG tubes and the comprehensive applicability of chemical cleaning are discussed. The integrity of structural materials such as carbon steel, low-alloy steel and stainless steel was maintained after the EPRI and KWU processes. KWU chemical cleaning tailored for crevice cleaning has been studied to improve its cleaning effectiveness in crevices and to control the corrosion depth of structural materials less than the criterion for corrosion depth. (author)

2006-11-01

413

Analysis of thermal hydraulics and soluble impurity distribution in horizontal steam generator PGV-1000 with STEG code  

International Nuclear Information System (INIS)

The 3D modeling of the thermal hydraulic processes and soluble impurity distribution in the horizontal steam generator PGV-1000 was fulfilled with the thermal hydraulic code STEG. Steady-state operation of horizontal seam generator PGV-1000 was analyzed at nominal power. The modeling of the soluble impurity distribution was fulfilled on the basis of the previous thermal hydraulic modeling results. The processes of the soluble impurity deposition on the steam generator tube bundles and deposits outwash were considered in the mathematical model of the code. The modeling was fulfilled for horizontal steam generators with different peculiarities in construction. Calculation results were compared with experimental results obtained at NPP. The agreement between calculated and experimental results is quite reasonable. Results of modeling are sensible to the peculiarities of the horizontal steam generator construction and consideration of these peculiarities in calculation ...

2003-04-20

414

Air-side performance of a parallel-flow parallel-fin (PF{sup 2}) heat exchanger in sequential frosting  

Energy Technology Data Exchange (ETDEWEB)

The thermal-hydraulic performance in periodic frosting conditions is experimentally studied for the parallel-flow parallel-fin heat exchanger, henceforth referred to as a PF{sup 2} heat exchanger, a new style of heat exchanger that uses louvered bent fins on flat tubes to enhance water drainage when the flat tubes are horizontal. Typically, it takes a few frosting/defrosting cycles to come to repeatable conditions. The criterion for the initiation of defrost and a sufficiently long defrost period are determined for the test PF{sup 2} heat exchanger and test condition. The effects of blower operation on the pressure drop, frost accumulation, water retention, and capacity in time are compared under the conditions of 15 sequential frosting cycles. Pressure drop across the heat exchanger and overall heat transfer coefficient are quantified under frost conditions as functions of the air humidity and air face velocity. The performances of two types ...

2010-09-15

415

Nuclear structure of light Ca and heavy Cr isotopes  

Energy Technology Data Exchange (ETDEWEB)

In the present thesis, the shell structure in exotic nuclei has been investigated. The focus of the work was on finding new experimental data in neutron-rich Cr and proton-rich Ca isotopes. The investigation of light Ca isotopes concentrated on the nucleus {sup 36}Ca which was produced in a knockout reaction from a radioactive {sup 37}Ca beam. For {sup 36}Ca, the excitation energy of the first 2{sup +} state has been measured for the first time. Furthermore, momentum distributions were analyzed using a Monte-Carlo simulation of the knockout reaction. This analysis yielded the contributions of neutrons from individual orbitals to the total knockout cross section. In principle, these may be used to calculate spectroscopic factors, but such a calculation is hampered by difficulties of present knockout-reaction models in predicting precise single-particle cross sections. The measured branching ratio to the ground and excited states, on the other hand, is close to the ...

2007-07-01

416

Thermal modeling of solar central receiver cavities  

Energy Technology Data Exchange (ETDEWEB)

Results are presented from a numerical model of the steady-state energy transfer in molten-salt-in-tube solar cavity receivers that includes convective energy transfer at a local (spatially resolved) level. Molten salt energy absorption and gray radiative transfer between all cavity surfaces are also included. This model is applied to the Molten Salt Subsystem Component Test Experiment (MSS/CTE) cavity receiver. Results for this receiver indicate the global (entire cavity) receiver thermal efficiency is invariant within a few percent to most parameters investigated, although front surface temperatures of the nonabsorbing walls vary considerably, and are particularly sensitive to the type of convective submodel used. Absorption efficiencies indicate the effects of the cavity enclosure environment. For all conditions investigated, tube inner wall temperatures remain under 855 K, ensuring that the salt remains chemically stable.

1989-05-01

417

Thermal model and thermodynamic performance of molten salt cavity receiver  

British Library Electronic Table of Contents (United Kingdom)

The design of a global steady-state thermal model of a 100kWt molten salt cavity receiver was developed as part of the key project of the Ministry of Science and Technology of People's Republic of China (MOST). In the design process, the following factors were analyzed: receiver area, heat loss (convective, emissive, reflective and conductive), number of tubes in the receiver panel, tube diameter and receiver surface temperature. The model was also used to calculate the receiver performance of the Sandia National Laboratories' molten salt electric experiment (MSEE). In addition, the thermal performance of the designed molten salt cavity receiver is presented for a fixed outlet flow rate and a fixed output temperature.

2010-01-01

418

Surface-loss power calculations for the LANSCE DTL  

Energy Technology Data Exchange (ETDEWEB)

The surface losses in the drift-tube linac (DTL) tanks 3 and 4 of the LANSCE linear accelerator are calculated using 3-D electromagnetic modeling with the CST MicroWave Studio (MWS). The results are used to provide more realistic power estimates for the 201.25MHz RF upgrade design within the LANSCE-R project. We compared 3-D MWS results with those from traditional 2-D Superfish computations for DTL cells and their simplified models and found differences on the level of a few percent. The differences are traced to a 3-D effect consisting in a redistribution of the surface currents on the drift tubes (DT) produced by the DT stem. The dependence of MWS results on the mesh size used in computations is also discussed.

2008-01-01

419

Steady state temperature profile in a cylinder heated by microwaves  

Energy Technology Data Exchange (ETDEWEB)

A new theory has been developed to calculate the steady state temperature profile in a cylindrical sample positioned along the entire axis of a cylindrical microwave cavity. Temperature profiles were computed for alumina rods of various radii contained in a cavity excited in one of the TM{sub 0n0} modes with n = 1, 2 or 3. Calculations were also performed with a concentric outer cylindrical tube surrounding the rod to investigate hybrid treating. The parametric studies of the total sample center and surface temperatures were performed as a function of the total power transmitted into the cavity. Also, the total hemispherical emissivity was varied at boundaries of the rod, surrounding tube, and cavity walls. The results are discussed in the context of controlling the average rod temperature and the temperature distribution in the rod during microwave processing.

1995-12-31

420

Sodium hideout studies in steam generator crevices  

International Nuclear Information System (INIS)

The steam generator availability is one of the important problems encountered during the pressurized water nuclear plant operation. Various kinds of corrosion phenomena were observed in the past. These phenomena result from the concentration of impurities mainly in three locations in the steam generators: the tubesheet crevices, the tube support plate crevices, and the sludge pile. Corrections were made in the design and the materials used but a number of steam generators suffer or will suffer from corrosion processes inducing in many cases forcing their replacement. In order to prevent or to retard the corrosions several laboratories have performed experiments to reproduce and to study the corrosion processes. The first step of the degradation is the concentration of chemical species. A method using /sup 24/Na as a radioactive tracer was used to establish the concentration kinetics of caustic which was identified as the major cause of the intergranular attack ...

421

Real-time neutron radiography for visualisation of interfacial geometry and phase distribution in two-phase flow  

International Nuclear Information System (INIS)

Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digital image format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).

1989-10-01

422

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

423

Peel-off case failure in thermal explosions observed by the deflagration cylinder test  

British Library Electronic Table of Contents (United Kingdom)

We have discovered a previously unidentified thermal explosion mode using the Los Alamos deflagration cylinder test (DFCT). The DFCT is a "pipe bomb"-style test similar to the detonation cylinder test (DTCT), which has been used for many years to calibrate detonation product equations of state. The shot is heated in an oven to a uniform test temperature. The pre-heated high explosive (HE) is triggered by a hot wire initiator on one end. The tube is back-illuminated by a bright light source, and its combustion-driven deformation and subsequent break-up are observed by a high-speed framing camera. Like the DTCT, the DFCT tube wall motion provides the primary diagnostic. A variety of reactive responses are possible, including quasi-steady deflagration and deflagration-to-detonation transition...

2009-01-01

424

Numerical and experimental investigation of shellside characteristics for RODbaffle heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

RODbaffle heat exchanger is a kind of shell-and-tube heat exchanger with eminent performance. Because of the characteristics of tube bundle support structure, fluid flow on shellside is longitudinal and periodical, and fluid flow is of symmetry in landscape orientation. According to the fluid flow characteristics on shellside and ignoring the impact of inlet, outlet and shell wall, a periodic flow unit duct was taken as the simplified model of the shellside to perform numerical simulation by using CFD code, FLUENT. It was found that the both errors in magnitude of the main fluid velocities and heat transfer coefficients between results of simulation and that of experiment or correlations are less than 10%, and the errors of pressure drop between simulation and correlation are no more than 20%. The detailed characteristics and relation of fluid flow and heat transfer on shellside of the RODbaffle heat exchanger were analyzed using the simulation ...

2008-05-15

425

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

426

Manufacture and first wall joining for an ITER primary wall module prototype: R and D phase with small scale mock-ups  

International Nuclear Information System (INIS)

In the frame of the Primary Wall Module prototype manufacturing for ITER, a consistent R and D phase was conducted in order to identify the industrial allowable tolerances and manufacturing problems which would occur when joining pieces by HIPping process during the PW module manufacturing. The purpose of this development was to give as industrial as possible manufacturing routes for joining together large Stainless Steel or DS-Copper pieces with Stainless Steel tubes and for bonding Beryllium tiles onto a curved component surface. The study concerned surface preparations, allowable gaps and joint geometry, Beryllium tile geometry, Titanium interlayer thickness, etc. This R and D phase also allowed the development and validation of different ultrasonic inspection tools needed for plate-plate, tube-plate, edge to edge plate bonding.

2001-10-01

427

Influence of feed water distribution pipe replacement on the water chemistry in the steam generator at Loviisa NPP  

International Nuclear Information System (INIS)

Imatran Voima Oy , (IVO) operates two Russian designed nuclear power plants of type VVER440/213. Unit 1 has been operating since 1977 and unit 2 since 1981. First damage of feed water distribution (FWD) pipes was observed in 1989. In closer examinations FWD-pipe T-connection and distribution nozzles suffered from severe erosion corrosion damage. Similar damages have been found also in other VVER-440 type NPPs. In 1994 the first FWD-pipe was replaced by a new design mounted over the tube bundle instead of the old FWD-pipe, which was located inside the tube bundle. The purpose of this paper is to describe the new FWD-pipe and discuss its effects on the steam generator chemistry. (author)

1998-06-01

428

Implications of the S-146 model for hideout and return in dented crevices  

International Nuclear Information System (INIS)

As part of Steam Generators Owners Group Project S-146, ''Diffusion and Hideout in Crevices,'' experimental data were obtained on chloride salt hideout and return in a controlled-boiling INCON system containing three electrically heated, thermocouple instrumented tube-to-support-plate intersections. The support plate simulants had first been caused to undergo, in situ, denting-type corrosion to the extent that substantial tube deformation was observed. Then chloride hideout and return measurements were made, using sodium chloride as the impurity additive. Experimental results were fitted to an elementary model for the crevice and its associated transport processes. Details on the experimental work and a description of the data-fitting method are given in the final report, NP-2979, dated March 1983.

1985-03-01

429

Hydrogen absorption behavior of Zr-2.5Nb pressure tubes in Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

The deuterium uptake behavior of Zr-2.5Nb pressure tubes in Wolsung Unit 1 was analyzed in terms of longitudinal location, operation time, and coolant temperature. The results were compared with those obtained from Canadian CANDU reactors. The amount of deuterium uptake was higher at the outlet part than at the inlet part and was also higher when subjected to a longer operation time and a higher coolant temperature. The hydrogen uptake of Zr-2.5Nb in a hydrogen gas atmosphere was dependent on the microstructure of the alloy. The aged Zr-2.5Nb consisting of {alpha}-Zr and {beta}-Zr phases. The hydrogen in the alloy decreased the rate of oxidation. This could be explained in terms of the cathodic controlled reaction of Zr-2.5Nb oxidation. (author)

1998-08-01

430

Heat transfer characteristics of superheater in the kraft recovery boiler; Soda kaishu boiler no kanetsuki ni okeru netsuryudo tokusei  

Energy Technology Data Exchange (ETDEWEB)

Accurate prediction of tube surface temperature is important for determining whether accelerated superheater corrosion will occur in kraft recovery boilers. A heat transfer model, which combines an iterative numerical solution scheme with a more realistic flue gas flow field obtained from the CFD code FLUENT, has been developed to predict the tube, steam and flue gas temperatures in the superheater region. Results of tests performed for a recovery boiler show that temperatures predicted using the model are in good agreement with actual temperatures measured using thermocouples. The presence of a large flue gas recirculation zone above the bullnose is shown to have an adverse effect on the heat transfer in the superheater region. 9 refs., 12 figs., 1 tab.

1997-03-25

431

Heat and fluid flow during the formation of metallic glasses by splat cooling  

Science.gov (United States)

A model is presented for heat and fluid flow during hammer and anvil splat cooling. Predictions are made for the effects of superheat and hammer speed on splat thickness, cooling rate, and subsequent glass formation. The regime of Newtonian heat flow is extended well beyond the previously accepted limiting value of Nusselt number. Measurements of the structure, stability, and thickness of Fe{sub 80}B{sub 20} and Pd{sub 80}Si{sub 20} hammer and anvil splats qualitatively confirm the model prediction. Variations of superheat in shock tube splats produced similar trends to those observed in the hammer and anvil device. In an attempt to vary the equivalent of hammer speed in a shock tube device, an orifice producing a supersonic shock wave was utilized. Significant splat flake thickness reductions resulted as compared to subsonic orifices.

432

Glass-heat-pipe evacuated-tube solar collector  

Science.gov (United States)

A glass heat pipe is adapted for use as a solar energy absorber in an evacuated tube solar collector and for transferring the absorbed solar energy to a working fluid medium or heat sink for storage or practical use. A capillary wick is formed of granular glass particles fused together by heat on the inside surface of the heat pipe with a water glass binder solution to enhance capillary drive distribution of the thermal transfer fluid in the heat pipe throughout the entire inside surface of the evaporator portion of the heat pipe. Selective coatings are used on the heat pipe surface to maximize solar absorption and minimize energy radiation, and the glass wick can alternatively be fabricated with granular particles of black glass or obsidian.

1981-08-06

433

Geothermal heat cycle research supercritical cycle with counterflow condenser in different orientations  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of binary power cycle performance utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation of the working fluid. The utilization of these concepts verified here will improve the net geofluid effectiveness (net watt hours plant output per pound of geofluid) about 20% over that of a conventional binary power plant. The major effect in this improvement is the ability to achieve integral, countercurrent condensation. Results are presented for the recent testing including those tests examining the performance of the countercurrent condenser at different tube inclinations and comparison with new design-base computer ...

1988-01-01

434

Eddy currents signal processing for steam generator inspection in PWR nuclear power plants  

International Nuclear Information System (INIS)

Steam generator tubes in nuclear power plants are periodically checked by means of eddy current probes. The output of a probe is composed of three types of signals: known events (rolling zone, support plates, U-bend part), noise (mainly metallurgical noise) and possible flaws. The latter are random transients, both in arrival time and in shape: they have to be detected and then estimated, before to be fed to the high level stages of a diagnostic system. The objective of the study presented is to develop a semi-automatic system, which could manage and process more than 1 M-bytes of data per tube and provide an operator with reliable diagnostics proposals within a few minutes. This can be achieved only by cooperation of several digital signal processing techniques: detection, segmentation, estimation, noise subtraction, adaptive filtering, modelization, pattern recognition. The paper describes some of these items.

1992-01-01

435

Development of electro-optical instrumentation for annular two-phase flow studies. [PWR  

Energy Technology Data Exchange (ETDEWEB)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-05-01

436

Development of Stronger and More Reliable Cast Austenitic Stainless Steels (H-Series) Based on Scientific and Design Methodology  

Energy Technology Data Exchange (ETDEWEB)

The goal of this project was to increase the high-temperature strength of the H-Series of cast austenitic stainless steels by 50% and the upper use temperature by 86 to 140 degrees fahrenheit (30 to 60 degrees celsius). Meeting this goal is expected to result in energy savings of 35 trillion Btu/year by 2020 and energy cost savings of approximately $230 million/year. The higher-strength H-Series cast stainless steels (HK and HP type) have applications for the production of ethylene in the chemical industry, for radiant burner tubes and transfer rolls for secondary processing of steel in the steel industry, and for many applications in the heat treating industry, including radiant burner tubes. The project was led by Duraloy Technologies, Inc., with research participation by Oak Ridge National Laboratory (ORNL) and industrial participation by a diverse group of companies.

2006-06-30

437

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

438

Design and fabrication of an 1-MW(th) ceramic tube bench-model solar receiver  

Energy Technology Data Exchange (ETDEWEB)

In 1976 the design and fabrication began of an 1 MWt Bench Model Solar Receiver (BMSR) to demonstrate and further develop the ceramic tube central receiver concept. Although many of the properties of silicon carbide are well documented, this material has never been utilized in an application of this type and size. Further investigation was undertaken to confirm the choice of silicon carbide against available metals and other ceramic materials. The BMSR is configured for testing at the Department of Energy's Central Receiver Test Facility in Albuquerque, New Mexico. Design and fabrication of the BMSR are highlighted in this report. Completion and testing of the BMSR are planned for the next phase of the project.

1982-05-01

439

Corrosion in steam generators of PWR type nuclear power plants  

International Nuclear Information System (INIS)

Problems are discussed of heat exchange tubes of Westinghouse type vertical steam generators exhibiting corrosion damage such as point corrosion, planar corrosion, tube denting, corrosion stress cracking, crevice corrosion, fretting corrosion and intergranular corrosion. Attention is also paid to problems of WWER-440 type horizontal steam generators, where the level fluctuation area is critical; noncompact porous deposits of the corrosion products give rise to crevice effects and cause significant concentration of chloride ions and other additions. This problem can be partly resolved by a modification of the collector design at the level variation area. An additional measure is the production of steel 08Kh18N10T with a very low level of harmful elements and inclusions. (Z.M.). 3 figs., 11 refs.

1988-03-01

440

Combined radiation and convection in absorbing, emitting, nongray gas-particulate tube flow  

Energy Technology Data Exchange (ETDEWEB)

The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as ...

1987-05-01

441

Combined radiation and convection in absorbing, emitting, non-Gray gas-particulate tube flow  

Energy Technology Data Exchange (ETDEWEB)

The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band position and band width, and temperature ratios (heated as well as ...

1985-01-01

442

Behaviour of the steam generators in the Belgian nuclear power plants  

International Nuclear Information System (INIS)

After a brief review of the degradations occurring on tubes of Inconel 600 in steam generators of PWR power stations emphasis is put on the conditioning of the secondary water and more particularly on the condensate treatment in the units of Doel which work on heavily polluted brackish water. The important role of non-destructive testing and eddy-current testing is also pointed out, method developed by Laborelec. The operational experience shows that Belgian stations are nearly not concerned by the degradations mostly found in power stations in other countries which shows the efficiency of the conditioning of the secondary water. On the other hand, other problems have occurred, resulting from: damage caused by foreign objects; fouling of tube before commissioning, cracking of bends and at the limit of the dudgeoning and leaking plugs. (AF).

1986-04-15

443

Evolution of improved varieties of sesame through induced mutations  

International Nuclear Information System (INIS)

Sesame varieties/genotypes showed a good response to radiation with gamma rays and treatments with EMS. In M_1 both gamma rays and EMS influenced germination, seedling height, survival of plants and pollen fertility/sterility, producing deleterious effects on these characters. Compared to black seeded genotypes, white seeded ones are more susceptible to radiation. Both gamma rays and EMS produced various types of morphological variations in M_2 generation. These were dwarf plant mutants, mottled and fleshy leaved mutants (sterile), fasciated stem, flower colour, altered phyllotaxy, early, uniculm, capsule size variations, multiple capsule/leaf axil, seed coat colour variations, indehiscent and semi-indehiscent type mutants. Moreover, studies on quantitative characters including seed yield revealed the induction of mutants in both positive and negative directions for such traits which made a good scope of selection of desirable mutants in M_2 generation. Mutants ...

2001-01-01

444

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

Energy Technology Data Exchange (ETDEWEB)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

1981-05-01

445

Water chemistry and corrosion in water-steam circuits of nuclear power plants  

International Nuclear Information System (INIS)

The water and steam circuits of steam generators in pressurized-water nuclear power plants are described together with the mechanism of denting, and the corrosion of spacer plates that leads to cracks in tubes by constriction. The different chemical specifications applicable to the water of the secondary circuit of the generators in normal operation and on first commissioning are listed. The results obtained and the measurements of chemical values taken in operation on the water in the secondary circuits of steam generators at Fessenheim and Bugey are presented.

446

Visualization and Analysis of Eddy Current Data from D-Probe  

Energy Technology Data Exchange (ETDEWEB)

Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The D-probe is furnished with a simultaneous dual function ...

2009-05-15

447

Visualization and Analysis of Eddy Current Data from D-Probe  

International Nuclear Information System (INIS)

Eddy current testing (ECT) method is widely used as the non-destructive evaluation (NDE) of the various kinds of material degradation occurring in nuclear power plants (NPPs) components including steam generator (SG) tubes. Detection of any defects or flaws in the steam generator tubes in the early stage is very important in maintenance of NPP for its primary role as the pressure boundary with thin wall thickness. Although the ECT technique provides lots of information for a SG management, it has a generic problem in its reliability due to a low ability in detect of small defects and some difficulty in a signal analysis. For the improvement of these shortcomings in conventional ECT, profile-MRPC (motorized rotating pancake coil) ECT technology was developed in KAERI. The key of this new technology is the development of new eddy current probes, designated as a diagnostic probe (D-probe). The D-probe is furnished with a simultaneous dual function ...

2009-05-01

448

Tube problems: worldwide statistics reviewed  

International Nuclear Information System (INIS)

EPRI's Steam Generator Strategic Management Project issues an annual report on the progress being made in tackling steam generator problems worldwide, containing a wealth of detailed statistics on the status of operating units and degradation mechanisms encountered. A few highlights are presented from the latest report, issued in October 1993, which covers the period to 31 December 1992. (Author).

449

Thermal fatigue failure at the White Cliffs solar thermal power plant  

Energy Technology Data Exchange (ETDEWEB)

The failure of receivers has been one of the main operating problems at the White Cliffs solar thermal power plant. This Technical Note reports the results of an initial investigation that identifies the cause as having been their thermal fatiguing of the tube walls. The fatigue appears to be caused by unstable heat transfer at vapor qualities below the point where critical heat flux is generally exceeded. Methods for avoiding this problem are tested.

1995-02-01

450

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater experiment LOF-10, the main parameters of the ...

2010-11-15

451

TRACE code modeling of the horizontal steam generator of the PACTEL facility and calculation of a loss-of-feedwater experiment  

International Nuclear Information System (INIS)

This paper describes the modeling of horizontal steam generator with the TRACE code and calculation results of a loss-of-feedwater (LOF-10) experiment at the PACTEL facility. Parallel Channel Test Loop (PACTEL) is an integral test facility for a VVER-440 type nuclear reactor. The main objectives were to prepare a simulation model for its horizontal steam generator with the TRACE thermal hydraulic code and assess different modeling options of the code. PACTEL experiment LOF-10 was chosen for this assessment. The calculation results showed that TRACE is capable in simulating horizontal steam generator behavior both in steady state and during loss-of-feedwater transient. The phenomenon of heat transfer from primary to secondary side, steam superheating and flow reversal in the lowest heat exchange tubes were studied in detail. Different nodalization options were introduced. In the simulation of PACTEL loss-of-feedwater experiment LOF-10, the main parameters of the ...

2010-11-01

452

Structural material irradiations in FFTF  

Energy Technology Data Exchange (ETDEWEB)

Information is presented concerning the Materials Open Test Assembly (MOTA); instrumentation and control system; MOTA neutronic data; pressurized tube specimens; stress-rupture measurements for reactor materials; miniature specimen design; the Interim Examination and Maintenance (IEM) cell at the FFTF; support services; and general information concerning the FFTF.

1985-01-01

453

Stress corrosion cracking susceptibility of alloy 800  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SGs) in PWRs and CANDUs are designed for at least a 30-year operating life. However, in the 15-25 years that SGs tubed with Alloy 600 have operated commercially, they have experienced reduced reliability, mainly due to SG tubing degradation. One of the degradation mechanisms that Alloy 600 SG tubing has suffered from is lead-induced stress corrosion cracking (PbSCC) in AVT and near-neutral SG environments. In contrast to Alloy 600 tubing, test data obtained in high temperature water indicate that Alloy 800 is resistant to cracking by lead and lead compounds. For Alloy 800 (cold worked, shot peened), the most aggressive environment is reported to be alkaline with minor concentration of PbO (80 ppm). Work by Max Helie et al. also concluded that Alloy 800 is not sensitive to lead assisted SCC for pH values close to neutrality, whereas it could be affected in high alkaline conditions. The ...

2002-07-01

454

Stress corrosion cracking susceptibility of alloy 800  

International Nuclear Information System (INIS)

Steam generators (SGs) in PWRs and CANDUs are designed for at least a 30-year operating life. However, in the 15-25 years that SGs tubed with Alloy 600 have operated commercially, they have experienced reduced reliability, mainly due to SG tubing degradation. One of the degradation mechanisms that Alloy 600 SG tubing has suffered from is lead-induced stress corrosion cracking (PbSCC) in AVT and near-neutral SG environments. In contrast to Alloy 600 tubing, test data obtained in high temperature water indicate that Alloy 800 is resistant to cracking by lead and lead compounds. For Alloy 800 (cold worked, shot peened), the most aggressive environment is reported to be alkaline with minor concentration of PbO (80 ppm). Work by Max Helie et al. also concluded that Alloy 800 is not sensitive to lead assisted SCC for pH values close to neutrality, whereas it could be affected in high alkaline conditions. The ...

2002-05-05

455

Steel microstructure engineering for large diameter tubes; Engenharia de microestrutura de acos para tubos de grande diametro  

Energy Technology Data Exchange (ETDEWEB)

High and ultra-high strength steels for pipelines are produced by properly handling the steel microstructure. The metallurgical principles involved in the microstructure control are presented, with emphasis on TMCP processing, that comprises conventional controlled rolling followed by accelerated cooling. (author)

2008-05-15

456

Safety provisions for steam generator in Mochovce nuclear power plant. BO CI 04 Integrity of primary collectors of VVER 440 steam generators  

International Nuclear Information System (INIS)

This paper dealt with the identification of possible damaging mechanism of the collector of the WWER 440 steam generator, cracking of primary collectors, corrosion damage of the protective coat of the primary collector circumferential weld, cracking of breathing space in the region of blinding effect by corrosion and strain, leaking of disassembling joint of the primary collector lid and with the integrity of heat exchanging tubes.

1997-11-19

457

Safety analysis and license of rod drop time issue at Daya Bay Nuclear Power Plant  

International Nuclear Information System (INIS)

The rod drop time event of the Daya Bay Nuclear Power Plant is caused by the malfunction of the guide tube developed by Framatome. Three temporary solutions were implemented successively and the long term solution was found in the process of searching for the root cause. The different solutions and the root cause are introduced. The safety analysis and license of the solutions are mainly discussed. Experiences and lessons are drawn by summarizing the important items related to nuclear safety.

458

Relationship between microstructural evolution and low cycle fatigue behaviour at 550/sup 0/C of alloy 800 grade 2  

Energy Technology Data Exchange (ETDEWEB)

In this study, deformation modes and precipitations have been characterized in test pieces made of alloy 800, grade 2 hyper-hardened state and age-conditioned for 3000 h at 550/sup 0/C, used for steam generator tubes of the Super Phenix Reactor, after continuous fatigue and fatigue-relaxation tests in the oligocyclic range. This microstructural study has provided an interpretation of the fatigue behaviour of the material.

1989-01-01

459

Phosphors for flat panel emissive displays  

Energy Technology Data Exchange (ETDEWEB)

An overview of emissive display technologies is presented. Display types briefly described include: cathode ray tubes (CRTs), field emission displays (FEDs), electroluminescent displays (ELDs), and plasma display panels (PDPs). The critical role of phosphors in further development of the latter three flat panel emissive display technologies is outlined. The need for stable, efficient red, green, and blue phosphors for RGB fall color displays is emphasized.

1995-07-01

460

Performance of large LWR system codes in calculating the steam-generator heat-transfer behavior  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a series of modeling experiences and problems in simulating the thermal-hydraulic behavior of large PWR steam generators using the RELAP4 and RELAP5 computer codes. Sensitivity studies investigating the heat transfer characteristics of both once-through and U-tube steam generators are discussed. Suggestions and recommendations are given for effective use and potential future improvements of these codes.

1982-01-01

461

Needs and opportunities for monitoring corrosion  

International Nuclear Information System (INIS)

Various electrochemical techniques are available to continuously monitor corrosion in conditions simulating those on the secondary side of PWR steam generators. This paper reviews those electrochemical techniques which are potentially useful to measure denting in tube-support crevices in situ. Attention is also given to corollary needs for monitoring the water chemistry which leads to corrosive attack. Finally some suggestions are offered for corrosion monitoring in autoclaves, model boilers and operating steam generators.

1985-03-01

462

Micro borehole drilling platform  

Energy Technology Data Exchange (ETDEWEB)

This study by CTES, L.C. meets two main objectives. First, evaluate the feasibility of using coiled tubing (CT) to drill 1.0 inches-2.5 inches diameter directional holes in hard rocks. Second, develop a conceptual design for a micro borehole drilling platform (MBDP) meeting specific size, weight, and performance requirements. The Statement of Work (SOW) in Appendix A contains detailed specifications for the feasibility study and conceptual design.

1996-10-01

463

Mandrel head for pressing out patches during repair of casing columns  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this invention is to assure operating reliability of a Mandrel head in tubes of various diameters. This goal is achieved in that it is equipped with movable expanding sectors, which are installed on a rigid conical plunger dye. It is also equipped with spring-loaded conical slides blocks which are installed on a shaft. The upper ends of the sectors of the sectorial head are attached by hinges to a rigid cone shaped plunger dye. The lower ends are installed with the possibility of interacting with the slide blocks.

1980-07-17

464

Lung studies with spiral CT. pitch 1 versus pitch 2  

International Nuclear Information System (INIS)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.

1999-03-01

465

Influence of temperature and velocity of 92% sulfuric acid on anodic behavior of stainless steels  

Energy Technology Data Exchange (ETDEWEB)

This paper investigates the anodic behavior of steels 12Kh18N10T, 10Kh17N13M2T, 08Kh22N6T, and 08Kh21N6M2T in 92% sulfuric acid. The aim of the study was to determine the parameters for anodic protection of shell-and-tube coolers. Results of the study are presented.

1986-03-01

466

Heavy water leak due to fretting of DN tube  

International Nuclear Information System (INIS)

Wolsung nuclear power plant has experienced four occasions of reactor shutdown owing to heavy water leaks since its commercial operation. Among these heavy water leaks, only one case was acute and brought about reactor shutdown but the other cases listed below were chronic and repaired after manual reactor shutdown. (author). 4 tabs., 10 figs.

1989-06-04

467

Forced and mixed convection heat transfer to supercritical CO{sub 2} vertically flowing in a uniformly-heated circular tube  

Science.gov (United States)

An experiment of heat transfer to CO{sub 2}, which flows upward and downward in a circular tube with an inner diameter of 6.32 mm, was carried out with mass flux of 285-1200 kg/m{sup 2} s and heat flux of 30-170 kW/m{sup 2} at pressures of 7.75 and 8.12 MPa, respectively. The corresponding Reynolds number at the tube test section inlet ranges from 1.8 x 10{sup 4} to 3.8 x 10{sup 5}. The tube inner diameter corresponds to the equivalent hydraulic diameter of the fuel assembly sub-channel, which is being studied at KAERI. Among the tested correlations, the Bishop correlation predicted the experimental data most accurately, but only 66.9% of normal heat transfer data were predicted within {+-}30% error range. The Watts and Chou correlation, which is claimed to be valid for both the normal and deteriorated heat transfer regime, showed unsatisfactory performance. A significant decrease in Nusselt number was observed in the range ...

2010-11-15

468

Flow-induced vibration specifications for steam generators and liquid heat exchangers  

International Nuclear Information System (INIS)

It is desirable to avoid vibration problems by following appropriate guidelines and specifications at the design stage. Accordingly, design specifications were developed to prevent tube failures due to vibration in nuclear steam generators and liquid heat exchangers. These specifications are outlined in this report. (author). 14 refs., 2 figs.

1983-06-15

469

Flow patterns and heat transfer coefficients in flow-boiling and convective condensation of R22 inside a micro fin of new design  

International Nuclear Information System (INIS)

Saturated flow boiling and convective condensation experiments for oil-free refrigerant R22 been carried out with a micro fin tube of new design and with a smooth tube. Both tube have the same outer diameter of 9.52 mm and are horizontally operated. Two-phase flow pattern data have been obtained in addition of heat transfer coefficient and pressure drops; more-over, adiabatic tests have been also performed in order for flow pattern map to cover even adiabatic flows. Data are for mass fluxes ranging from about 90 to 400 Kg/s m"2. In boiling tests, the nominal saturation temperature is 5 degree C, with inlet quality varying from 0.2 to 0.6 and the quality change ranging from 0.1 to 0.5. In condensation, results are for saturation temperature equal to 35 degree C, with inlet quality between 0.8 and 0.4, and quality change within 0.6 and 0.2. The comparison shows a large heat transfer augmentation with a moderate increment of ...

1998-01-01

470

Field trial of a fast single-pass transmit-receive probe during Gentilly II steam generator tube inspection  

International Nuclear Information System (INIS)

A new generation of transmit-receive single-pass probes, denoted as C6 or X probe, was field tested during the Gentilly II, 2000 steam generator tube inspection. This probe has a performance equivalent to rotating probes and can be used for tubesheet and full-length inspection at an inspection speed equivalent to that of bobbin probes. Existing C3 transmit-receive probes have been demonstrated to be effective in detecting circumferential cracks. The C5 probe can detect both circumferential and axial cracks and volumetric defects but cannot discriminate between them. The C6 probe expands on the capabilities of both probes in a single probe head. It can simultaneously detect and discriminate between circumferential and axial cracks to satisfy different plugging criteria. It has excellent coverage, good defect detectability, and improved sizing and characterization. Probe data is displayed in C-scan format so that the amount of data to be analyzed is similar to ...

2000-11-19

471

Eldroerserosion och Belaeggning av Eldroer: En Litteraturstudie (Gun Barrel Erosion and Coating of Gun Barrels: A Literature Review).  

Science.gov (United States)

Erosion is the main contributing factor to the decrease in lifetime of gun barrels. The precision, muzzle velocity and fire range deteriorate when the surface inside the gun tube is eroded. This study deals with gun barrel material, what happens in the ba...

2002-01-01

472

Effects of temperature and time of exposure on the flammability limits of hydrogen-air mixtures  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the present work was to establish the flammability limits of hydrogen in air for upward vertical flame propagation at elevated temperatures up to 350 deg and atmospheric pressure in a conventional stainless steel test tube apparatus, and to investigate the extent to which a prolonged exposure (i.e., residence time) of the mixture to elevated temperatures before spark ignition may influence the value of the flammability limits. 9 refs.

1998-07-01

473

EFFECTIVE CONTROL OF SECONDARY WATER POLLUTION FROM FLUE GAS DESULFURIZATION SYSTEMS  

Science.gov (United States)

The report describes tests to demonstrate the feasibility of using a vertical-tube, falling-film, vapor-compression evaporator to concentrate waste water from a flue gas desulfurization (FGD) process. Tests showed that waste water from the Chiyoda FGD process can be concentrated ...

474

Development of an experimental installation for short-lived isotopes production in INR linac  

International Nuclear Information System (INIS)

A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.

2010-01-01

475

Desulphurization of hot reducing gases in the entrained bed reactor  

Energy Technology Data Exchange (ETDEWEB)

Using an experimental pilot plant, designed and built for the tests, the influence of the following parameters was determined: desulphurization of the test gas, temperature, residence time in the reactor tube, concentration of the hydrogen sulphide and desulphurization agent, size of the particles which comprise the agent and composition of the gas. Allowance was made for the effect of calcination and carbonisation. Desulphurization was carried out with limestone on a gaseous mixture of CO and H/sub 2/. A mathematical description of the test findings and yield is presented. 8 refs.

1986-08-01

476

Design of the local trigger board for the Daya Bay reactor neutrino experiment  

British Library Electronic Table of Contents (United Kingdom)

We have designed a local trigger board for the Daya Bay reactor neutrino experiment, which is aimed to measure the neutrino mixing angle sin22?13 with a precision down to 1% level. The local trigger board processes both the total number of coincident photomultiplier tube (PMT) hits and the PMT energy sum to make trigger decisions. With this design, a high trigger probability is achieved to meet the system requirement. The design of the local trigger board is presented.

2011-01-01

477

Design concept and testing of an in-bundle gamma densitometer for subchannel void fraction measurements in the THTF electrically heated rod bundle  

International Nuclear Information System (INIS)

A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.

478

Corrosion resistant coatings for silicon carbide heat exchanger tubes: Topical report  

Energy Technology Data Exchange (ETDEWEB)

This heat exchanger is a critical step in the development of the Externally Fired Combined Cycle power system, a direct-coal combustion power plant (gas turbine). SiC is the only material with the needed resistance to creep, thermal shock, and oxidation; however a protective coating is needed. Ten candidate materials were identified: alumina-based materials, materials stable with SiO, and low expansion materials. An initial screening study should be performed.

1996-09-01

479

Corrosion in power plant condensers  

International Nuclear Information System (INIS)

A historical overview of corrosion problems found in power plant condensers and mitigation procedures is presented. The paper is organized according to alloy type and failure mode. Alloys considered are copper-base alloys, stainless steels and titanium. Failure modes discussed include erosion-corrosion, sulfide attack, environmentally assisted cracking, galvanic corrosion, steam condensate corrosion, pitting corrosion, and dealloying. Mitigation procedures discussed include cathodic protection, ferrous ion injection, as well as tube cleaning and layup practices.

480

Computer modelling of eddy current probes for ISI of pressure tube/calandria tube assemblies in PHWRs  

International Nuclear Information System (INIS)

Non-destructive Evaluation (NDE) plays a major role in ensuring the safe and reliable operation of PHWRs which are the mainstay of India's nuclear power programme. An important in-service inspection (ISI) requirement in these reactors is carried out through Eddy Current Testing (ECT) of the pressure tube (PT)/calandria tube (CT) assemblies. The material of construction of these assemblies is zircaloy-2. The two main objectives of this ISI are the detection of garter spring between CT and PT and the profiling of gap between CT and PT. The paper discusses the work carried out at the authors' laboratory on the development of ECT probes for ISI of PT/CT assemblies. Emphasis has been given on the work done on the design and optimisation of the probes using computer modeling. A 2-D finite element code has been developed for this purpose. The code is developed around a diffusion equation which can be derived from Maxwell's equations governing the ...

1991-12-01

481

Comment on 'Magnetic braking revisited: activities for the undergraduate laboratory'  

International Nuclear Information System (INIS)

Here, we consider a recent paper concerned with magnetic braking by induced currents (Ireson and Twidle 2008 Eur. J. Phys. 29 745-51). Our objective is to elucidate why measurement of speed in which a magnet is dropped through a non-ferromagnetic conductive tube depends on its geometry in a non-monotonic way, which was not clearly explained by the authors. (letters and comments)

2009-03-01

482

Clinical application of FCR for the portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-08-01

483

Clinical application of FCR for the portable chest radiographs in ICU  

International Nuclear Information System (INIS)

The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).

1989-01-01

484

Characteristics of boiling transition of tight lattice rod assembly  

International Nuclear Information System (INIS)

Critical power characteristics of tight lattice rod assembly was investigated using a simple-shaped experimental apparatus. An electrically heated rod with four spacers was placed in a circular tube, and boiling transition condition for a rod in an annular geometry was clarified varing annulus clearance. It was found that critical heat flux depends strongly on the clearance accoding as the gap becomes smaller. This results was compared with KfK correlation and the trends were well correlated. (author).

485

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

Energy Technology Data Exchange (ETDEWEB)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for the original ...

2010-05-15

486

Characteristics Testing of the ECT Bobbin Probe for S/G Tube Inspection  

International Nuclear Information System (INIS)

The bobbin probe technique is basically one of the important ECT methods for the steam generator tube integrity assessment that is practiced during each plant outage. The bobbin probe also is the essential component which consists of the whole ECT examination system, and provides a decisive data for the evaluation of tube integrity in compliance with acceptance criteria described in specific procedures. The selection of probe is especially important because the quality of acquired ECT data is determined by the probe design characteristics, such as geometry and operation frequency, and has an important effect on examination results. The Electric Power Research Institute (EPRI) has recently defined the procedures for the qualification of eddy current hardware and technique. These procedures provide two basic methods for qualification. Flawed tube removed from operation, or artificial flaw is required for the original ...

2010-05-01

487

Amp-PCR: Combining a Random Unbiased Phi29-Amplification with a Specific Real-Time PCR, Performed in One Tube to Increase PCR Sensitivity  

UK PubMed Central (United Kingdom)

In clinical situations where a diagnostic real-time PCR assay is not sensitive enough, leading to low or falsely negative results, or where detection earlier in a disease progression would benefit the...Full Text Available

488

Actinide chemistry: From test tube to billion dollar plant-A BNFL perspective  

Science.gov (United States)

British Nuclear Fuels (BNFL) is currently operating its third generation of nuclear plant for the management of irradiated nuclear fuel. Development for the fourth generation plant must meet requirements for processing higher burn-up fuel with lower unit costs, lower environmental impact, better process control, and more flexible control of actinides. .

2000-07-01

489

A search for tachyons in extensive air showers  

International Nuclear Information System (INIS)

A search for tachyons, or other particles detectable by G-M counter tubes or liquid scintillators, arriving during the approximately 100#mu#s immediately preceding extensive air showers (primary energy approximately 10"1"5 eV) has provided no positive evidence for the existence of such particles. (orig.).

490

Mass and charge transfer on various relevant scales in polymer electrolyte fuel cells[Dissertation 16991  

Energy Technology Data Exchange (ETDEWEB)

This dissertation is concerned with the development, experimental diagnostics and mathematical modelling and simulation of polymer electrolyte fuel cells (PEFC). The central themes throughout this thesis are the closely interlinked phenomena of mass and charge transfer. In the face of developing a PEFC system for vehicle propulsion these phenomena are scrutinized on a broad range of relevant scales. Starting from the material related level of the membrane and the gas diffusion layer (GDL) we turn to length scales, where structural features of the cell additionally come into play. These are the scale of flow channels and ribs, the single cell and the cell stack followed by the cell, stack, and system development for an automotive power train. In Chapter 3 selected fundamental material models and properties, respectively, are explored that are crucial for the mathematical modelling and simulation of PEFC, as needed in some succeeding parts of this work. First, established mathematical ...

2007-07-01

491

Things fall apart: topology change from winding tachyons  

Energy Technology Data Exchange (ETDEWEB)

We argue that closed string tachyons drive two spacetime topology changing transitions - loss of genus in a Riemann surface and separation of a Riemann surface into two components. The tachyons of interest are localized versions of Scherk-Schwarz winding string tachyons arising on Riemann surfaces in regions of moduli space where string-scale tubes develop. Spacetime and world-sheet renormalization group analyses provide strong evidence that the decay of these tachyons removes a portion of the spacetime, splitting the tube into two pieces. We address the fate of the gauge fields and charges lost in the process, generalize it to situations with weak flux backgrounds, and use this process to study the type 0 tachyon, providing further evidence that its decay drives the theory sub-critical. Finally, we discuss the time-dependent dynamics of this topology-changing transition and find that it can occur more efficiently than analogous transitions on ...

2005-10-15

492

Things Fall Apart: Topology Change From Winding Tachyons  

Energy Technology Data Exchange (ETDEWEB)

We argue that closed string tachyons drive two spacetime topology changing transitions--loss of genus in a Riemann surface and separation of a Riemann surface into two components. The tachyons of interest are localized versions of Scherk-Schwarz winding string tachyons arising on Riemann surfaces in regions of moduli space where string-scale tubes develop. Spacetime and world-sheet renormalization group analyses provide strong evidence that the decay of these tachyons removes a portion of the spacetime, splitting the tube into two pieces. We address the fate of the gauge fields and charges lost in the process, generalize it to situations with weak flux backgrounds, and use this process to study the type 0 tachyon, providing further evidence that its decay drives the theory sub-critical. Finally, we discuss the time-dependent dynamics of this topology-changing transition and find that it can occur more efficiently than analogous transitions on ...

2005-02-04

493

Thermal energy storage system using stearic acid as a phase change material  

Energy Technology Data Exchange (ETDEWEB)

The thermal performance and phase change stability of stearic acid as a latent heat energy storage material has been studied experimentally. The thermal performance and heat transfer characteristics of the stearic acid were tested and compared with other studies given in the literature. In the present study, parameters such as transition times, temperature range and propagation of the solid-liquid interface as well as the effect of heat flow rate on the phase change stability of stearic acid as a phase change material (PCM) were studied. The experimental results showed that the melting stability of the PCM is better in the radial direction than in the axial direction. The variation in the melting and solidification parameters of the PCM with the change of inlet water temperature is also studied. We observed that while the heat exchanger tube is in the horizontal position, the PCM has more effective and steady phase change characteristics than in the vertical ...

2001-07-01

494

Improved eddy-current inspection for steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Computer programs have been written to allow the analysis of different types of eddy-current probes and their performance under different steam generator test conditions. The probe types include the differential bobbin probe, the absolute bobbin probe, the pancake probe and the reflection probe. The generator test conditions include tube supports, copper deposits, magnetite deposits, denting, wastage, pitting, cracking and IGA. These studies are based mostly on computed values, with the limited number of test specimens available used to verify the computed results. The instrument readings were computed for a complete matrix of the different test conditions, and then the test conditions determined as a function of the readings by a least-squares technique. A comparison was made of the errors in fit and instrument drift for the different probe types. The computations of the change in instrument reading due to the defects have led to an inversion'' ...

1989-01-01

495

Historical development of alloy 800  

International Nuclear Information System (INIS)

Alloy 800 was developed in 1949 by The International Nickel Company, Inc. The basic composition, nominally 32wt.%Ni, 20.5wt.%Cr and 46wt.%Fe, was designed to provide a stable, fully austenitic structure and to impart high strength combined with resistance to oxidation, carburization and corrosion in a wide variety of aggressive industrial environments at elevated temperatures. In the short span of twenty-five years, alloy 800 has earned a unique position in the family of heat- and corrosion-resistant materials. Established uses include a wide range of applications in the industrial heating field, in the petro-chemical industry, in domestic appliances and in food processing equipment. The good performance of alloy 800 in these applications has led to its use as boiler tube material both in fossil-fired plants and in HTGR and PWR nuclear power systems. Recently, it was specified for a PHW CANDU reactor and it is now being considered as heat exchanger ...

496

Experimental investigation on the fretting wear of alloy 800 in room remperature water  

Energy Technology Data Exchange (ETDEWEB)

Fretting wear test in room temperature water was performed to evaluate the wear coefficient of CANDU (CANadian Deuterium Uranium) steam generator (SG) tube material (Alloy 800) against 410 type martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel 690. Test conditions are 10{approx}30N of normal load, 200{approx}450mm of sliding amplitude and 30Hz of frequency. The result indicated that the wear rate of Alloy 800 was higher than those of Inconel 690 at various test condition such as normal loads, sliding amplitudes etc. From the results of SEM observation, there was little evidence of plastic deformation layer that were dominantly formed on the worn surfaces of Inconel 690. Also, wear particles in Alloy 800 were released from contacting asperities deformed by severe plastic flow during fretting wear. Main cause of wear rate between Alloy 800 and Inconel 690 may be due to the difference of hardness between ...

2002-05-01

497

Experimental investigation on the fretting wear of alloy 800 in room remperature water  

International Nuclear Information System (INIS)

Fretting wear test in room temperature water was performed to evaluate the wear coefficient of CANDU (CANadian Deuterium Uranium) steam generator (SG) tube material (Alloy 800) against 410 type martensitic stainless steels. The main focus is to compare the wear behaviors between Alloy 800 and Inconel 690. Test conditions are 10#approx#30N of normal load, 200#approx#450mm of sliding amplitude and 30Hz of frequency. The result indicated that the wear rate of Alloy 800 was higher than those of Inconel 690 at various test condition such as normal loads, sliding amplitudes etc. From the results of SEM observation, there was little evidence of plastic deformation layer that were dominantly formed on the worn surfaces of Inconel 690. Also, wear particles in Alloy 800 were released from contacting asperities deformed by severe plastic flow during fretting wear. Main cause of wear rate between Alloy 800 and Inconel 690 may be due to the difference of hardness between ...

2002-05-01

498

Approximate analysis of non-uniform gas flow through layered burdens  

Energy Technology Data Exchange (ETDEWEB)

An approximate analyzing model was developed to predict the azimuth of zigzag streamline, the distribution ratio between two neighboring layers and the radial distribution among the layers of the gas passing through the shaft of blast furnace loaded in layers. The theoretical basis of the approximate analysis is composed of the material balance derived from the assumption that any stream line surrounded with two streamlines is isolated and no material transfer occurs through the tube wall, and of the energy theory that the stream tube and passage are formed so that the total pressure drop in the whole system is the minimum. The effects of the apparent angle of repose between two layers, the packing volume and the passage resistance on the non-uniform flow in the layer were evaluated on the basis of the model. The result calculated by the approximate analysis agrees with the result by the numerical analysis based on the equations of continuity ...

1988-02-01

499

Analysis of flow-induced vibration by improvement of design in UCN 5,6 steam generator  

Energy Technology Data Exchange (ETDEWEB)

Youngkwang Unit 3,4 and Ulchin Unit 3 and 4 have had problem of the KSNP Steam Generator due to a severe fretting wear on the tube. In particular, the wears were localized and concentrated in the upper part of U-bend of the Central Cavity region. At the upper tube bundle Central Cavity, the fluid flow velocities and void fraction are very high, because the steam is made by high heat transfer at secondary region. Also, this region is affected easily by fretting wear due to it's unsupported span is longer than another regions. The fretting wear is assumed to be result of Flow-Induced Vibration (F. I. V), which can occur by many mechanisms. EFDP was added to UCN 5,6 for prevent fretting wear by the SEC LCC and DSHIC, a company of design and manufacture of the steam generator, respectively. In order to evaluate the efficacy of EFDP, ANSYS and ATHOS-3 Code were used. From sensitivity analysis and calculation results, Density and Velocity ...

2001-10-01

500

Analysis of flow-induced vibration by improvement of design in UCN 5,6 steam generator  

International Nuclear Information System (INIS)

Youngkwang Unit 3,4 and Ulchin Unit 3 and 4 have had problem of the KSNP Steam Generator due to a severe fretting wear on the tube. In particular, the wears were localized and concentrated in the upper part of U-bend of the Central Cavity region. At the upper tube bundle Central Cavity, the fluid flow velocities and void fraction are very high, because the steam is made by high heat transfer at secondary region. Also, this region is affected easily by fretting wear due to it's unsupported span is longer than another regions. The fretting wear is assumed to be result of Flow-Induced Vibration (F. I. V), which can occur by many mechanisms. EFDP was added to UCN 5,6 for prevent fretting wear by the SEC LCC and DSHIC, a company of design and manufacture of the steam generator, respectively. In order to evaluate the efficacy of EFDP, ANSYS and ATHOS-3 Code were used. From sensitivity analysis and calculation results, Density and Velocity into the ...

2001-10-01