Some comments are given on the recycling of waste, mainly plastics, as evaluated from the viewpoint of energy environment. Discussed about the waste in general are the definition and classification, generation and resource recovery rates, current state of recycling, problems about recycling, related legislation, and current conditions overseas. Discussed about the treatment and recycling of plastics waste are the characters and use of plastic product, current state of waste plastics treatment, current state of waste plastics recycling (material recycling, thermal recycling), energy recovery by thermal recycling, quantity recyclable from waste plastics, energy consumption and cost for waste plastics recycling, effect and impact of increase in waste plastics in case material recycling is forwarded, and prospect of waste plastics recycling. 11 figs., 10 tabs.
To use such sites very effectively, pile foundations will be used for soil stabilization and for important structures for the prevention of subsidence. Negative friction that may ensue from the differential settlement of the soil has to be prevented. Measures against gas will include gas collecting and exhausting facilities in the lower parts of structures, natural and forced exhaust systems, and gas detection/warning units. For revegetation, plants strong against bad soil should be selected, they should be protected from generated gas with protecting sheets or the like, and a thick layer of vegetation-capable soil needs to be laid. Replacement, compaction, and solidification are the fundamentals of soil improvement at wastes final treatment locations and of soil-related pollution prevention in the vicinity of the newly produced sites. Across the country, the service life expectancy is approximately 7-8 years for general wastes and approximately 2.3 years for industrial wastes, and ...
Kawasaki Heavy Industries, Ltd. has developed a gas turbine combined cycle and cogeneration plant computer aided engineering (CAE) system, which creates cycle heat balance automatically on given configurations of gas turbines, heat recovery boilers, steam turbines and auxiliaries. The system can predict the performance of the plant as a function of control set points, loads, process steam requirements and ambient conditions, which enables accurate and fast design of gas turbine combined cycle and cogeneration plants. (author)
The feasibility study was conducted on a model project in Vietnam, aimed at solving the environmental pollution problems resulting from use of coal by demonstrating and disseminating the Japan's environmental technologies in the Southeast Asian countries. The feasibility study was conducted for the Cua Ong Coal Preparation Enterprise, which has the largest coal preparation capacity in Vietnam and port facilities. It is treating raw coal from 10 coal mines for classification and preparation, and shipping coal of various types that meet the standards for domestic use and export. The survey results point out that unrecovered coal remains in waste water discharged from the coal preparation plants to pollute the sea area, and that quantity of the refuse increases because of the unrecovered coal it contains. The environmental technologies needed to introduce include modification to variable wave pattern type jigging separator, refuse height measuring instrument and automatic ...
Introduction of geothermal heat pump systems, which depend on temperature differential, is investigated for urban areas, which have large energy demands. Results of the surveys on the current situations of geothermal heat pump (GHP) systems indicate that they have already numbered 300,000 units in USA and totaled more than 50,000 units in Switzerland and Northern European countries, and that they are increasing at an annual rate of higher than 10%. The results also indicate that introduction of these systems are well feasible in Japan, which generally has better topographical conditions than American and European countries, and the GHP system with vertical ground heat exchanger is investigated for its topographical and environmental considerations. These systems could annually abate approximately 52 million tons of CO2 (4.3% decrease), if disseminated to all households. They are also expected to help control the heat island phenomenon, and reduce peak power consumption. The ...
Substation machinery foundation works have some features such as a number of work cases second look cases in design, and so forth. The Tohoku Electric Power Co., Inc. started the development of a system generally supporting the substation machinery foundation design to practical use the Engineering Work Station (EWS) introduced to the civil engineering department as a part of improvement of management efficiency. At first, rigid foundation design support system (TRAD) and slab foundation design support system (KANSAS-IN) automatically conductible with from preparation of design and amount calculation sheet to preparation of design drawing was developed, which was began to operate since March of 1996. As a result, the rigid foundation design became able to execute fully automatic works from preparation of design and its drawing to amount calculation. And, on the slab foundation design, three dimensional FEM analysis could be executed for shorter time, which made wide range of time ...
The R and D were carried out of a detecting system for measurement of data on the bottom of geothermal well, data transmission and signal processing, and an analysis system for well drilling trajectory control and well assessment while geothermal well drilling based on the data obtained by the detecting system. The paper reported the results of the technology development in fiscal 1996. In the development of the detecting system, improvement/design were conducted on a mud pulse generator constituting sonde, well bottom signal processing equipment, mode switch and inclined information sensor, and the system equivalent to the actual one was manufactured to conduct a running test at high temperature/pressure. Moreover, a test to confirm heat resistance of electronic parts was made for further improvement in heat resistance of the sonde, in order to obtain the data. In the development of an analysis system, conducted were enhancement of operability of the planning/indication portions of ...
This paper reports the result obtained during fiscal 1994 on a demonstration research on photovoltaic power generating systems. Solar cells with an output of 750 kW, storage battery facilities with an output of 3,058 kWh, three DC-AC converters with a rating of 250 kW, and a diesel generator with an output of 300 kW having been installed up to the previous fiscal year were combined to perform comprehensive adjustments and tests such as battery charge/discharge tests and AC parallel operation tests. The battery charge/discharge tests revealed that the 10 hour rate discharge capacity meets the specifications, and the batteries are free of deterioration after a demonstration operation of about 4.5 months. Difference between the power generation record and the planned value is thought due to the following reasons: the array output data in a power line connected system come about 90% of the simulation result due to correction coefficient for the solar cell conversion efficiency; the ...
Described herein are the results of the FY1994 research program for structural defects of silicon-based amorphous materials for solar cells. The study on light generation defects of the a-Si:H system and rejuvenation process by annealing establishes the effects of light irradiation time on changed neutral dangling bond density as a result of light irradiation at varying temperature of 77K, room temperature and 393K. The study on annealing to rejuvenate light generation defects of various types of a-Si-H systems establishes the activation energy distribution with respect to annealing to remove light-induced defects, showing that hydrogen affects the distribution of light-induced defects. The study on decaying process of light-induced ESR for undoped and N-doped a-Si:H systems observes the decaying process of light-induced ESR, after light is cut off, extending for a period of several seconds to several hours at 77K for the a-Si-H systems containing N in a range from 0 to 12at%. The ...
A study was made for the purpose of electrification of unelectrified zones of the mountainous areas in developing countries using extremely small hydroelectric power facilities. The target for this project is a development of a micro hydroelectric power system with a size of about 5kW, which is estimated regarding that 1 village has 80 houses and each house needs electricity of 60W. In the study, the low-head system using a weir of irrigation channels in Subang pref. of West Java state was selected by the evaluation of access, stability of flow rate, natural conditions, etc. The hydroelectric power plant is of a flow-in method in which water is taken from the left bank and is injected/discharged to the downstream of the left bank. As the hybrid complementary power source, hybrid battery with a two-hour charging time at peak and a capacity of 3.5kWh was considered. When estimating the construction cost of the hybrid micro hydroelectric power system and equalizing by durable years, the ...
Feasibility study is conducted for introduction of a top pressure recovery turbine (TRT) in China's Panzhihua Iron and Steel (Group) Company, Sichuan Province, for the potential project to simultaneously contribute to abatement of the greenhouse effect gases and to sustainable economic development of the counterpart country. This project considers to adopt the TRTs in 3 blast furnaces (No.1 to 3) of the 4 furnaces in service at the works, producing 2,500,000 t/y of crude steel, where the No.4 furnace is already provided with the model system and not considered in this project. According to the feasibility study results, the total fund required is 5.46 billion yen (Japan-made facilities: 4.172 billion yen, and China-made facilities: 1.288 billion yen), energy-saving effect is 36,467 t/y as crude, greenhouse effect gas emission abatement effect: 112,830 t/y as CO2, and pay-off period is 8.3 years. This plan considers to adopt almost the same facilities as those for the model ...
Described herein are the results of the FY1994 research program for analysis and evaluation for thin film solar cells. The study on quantitative analysis of hydrogen atoms in a plasma determines quantity of hydrogen atoms in the plasma of monosilane diluted with hydrogen. It is found, contrary to expectation, that quantity of hydrogen atoms in the plasma decreases as it is more diluted with hydrogen. The study on light-induced degradation of the thin chlorine-base amorphous silicon films confirms that the plasma CVD method with 20% of dichlorosilane gas added to monosilane gas produces the thin amorphous silicon film 3 times faster than the conventional method. The thin film has essentially the same defect density as the one prepared by the conventional method, showing good photoelectric characteristics. The thin film of chlorinated amorphous silicon has a 1 digit lower defect density than the conventional one of amorphous silicon, as revealed by the accelerated degradation test with ...
Inverter introduced in this paper is intended for use in medium-capacity photovoltaic power generation systems designed for industries in general. Interconnection is carried out at a low-voltage 210V point receiving from a commercial 3 phase-3 cable 6.6kV high voltage incoming panel. So as to ensure stable extraction of power in the maximum degree from a photovoltaic power generation system that is naturally unstable, this inverter monitors voltage and power, and behaves in a fully automated way. A maximum power point tracking (MPPT) control function is provided, which measures the power level at the current operating voltage point A, changes the operating voltage to a voltage value B which is lower than the point A voltage by 3V and to a voltage value C which is higher than the point A voltage by 3V, and measures the power level at each point. Comparison is then made between the values measured at the said points on a PV profile, and the operating voltage value is moved toward the C ...