WorldWideScience
 
 
2

Jumbo cups for revision of acetabular defects after total hip arthroplasty: a retrospective review of a case series  

British Library Electronic Table of Contents (United Kingdom)

The treatment of acetabular bone defects presents a great challenge in revision total hip arthroplasty (THA). The purpose of this study was to evaluate the clinical and radiological outcome of revision THA using jumbo cups for acetabular reconstruction after applying the bone-grafting technique. We studied 17?patients with acetabular defects ranging from Type 2A to Type 3A according to Paprosky`s classification. According to the AAOS-score twelve patients were classified as Type II and five patients as Type III. Uncemented press-fit cups with an outer diameter larger than 64?mm were used in all cases. Fifteen patients received morselized bone allografts. In eight patients an additional screw fixation was necessary. The mean follow-up period was 82?months (range 33?149). The mean Harris Hip...

2008-01-01

3

CT evaluation of acetabular fractures  

International Nuclear Information System (INIS)

The paper deals with sixteen cases of acetabular fractures studied with CT. After a short description of the normal CT findings, the different kind of fractures are reported. The usefulness of CT examination in evaluating acetabular fractures and their complications is confirmed both in conservative treatment and surgical approach.

1986-01-01

4

A cementless elastic monoblock socket in young patients: a ten to 18-year clinical and radiological follow-up  

British Library Electronic Table of Contents (United Kingdom)

The survival of acetabular components depends on several factors: wear, osteolysis and septic or aseptic loosening. Osteolysis seems to be the main cause for concern in cementless arthroplasties. Acetabular osteolysis results from particle debris and segmental unloading of acetabular bone by rigid sockets. We investigated a cementless elastic monoblock socket with regard to acetabular osteolysis and aseptic loosening in a cohort of young patients. We evaluated 158 hip arthroplasties with a minimum follow-up of ten?years (ten to 18) and a mean age of 42?years (18?50). The overall revision rate at 14?years was 80% with a 98% survival rate for aseptic loosening. The mean polyethylene wear rate was 0.11?mm/year. Progressive acetabular osteolysis was seen in 3% of patients evaluated. In conclus...

2011-01-01

5

Case Reports: Fractures of Threaded Cups: Rare Complications of a Well-established Implant  

UK PubMed Central (United Kingdom)

The use of cementless threaded cups in THA is a well-established treatment. Fractures of the cups are rare complications recorded in individual cases with material defects being discussed as the primary...Full Text Available

2009-03-01

6

tiAtiA ,', - NASA Technical Report Server (NTRS)  

Science.gov (United States)

the nozzle ring, the collector cup, and the impeller fuel-distribution ... sity of the vaned collector cup and the fuel-transfer passages ..... closure ...

8

Biomimetic helical rosette nanotubes and nanocrystalline hydroxyapatite coatings on titanium for improving orthopedic implants  

Science.gov (United States)

Natural bone consists of hard nanostructured hydroxyapatite (HA) in a nanostructured protein-based soft hydrogel template (ie, mostly collagen). For this reason, nanostructured HA has been an intriguing coating material on traditionally used titanium for improving orthopedic applications. In addition, helical rosette nanotubes (HRNs), newly developed materials which form through the self-assembly process of DNA base pair building blocks in body solutions, are soft nanotubes with a helical architecture that mimics natural collagen. Thus, the objective of this in vitro study was for the first time to combine the promising attributes of HRNs and nanocrystalline HA on titanium and assess osteoblast (bone-forming cell) functions. Different sizes of nanocrystalline HA were synthesized in this study through a wet chemical precipitation process following either hydrothermal treatment or sintering. Transmission electron microscopy images showed that HRNs aligned with nanocrystalline HA, which ...

2008-01-01

9

Computed tomography of the acetabular fractures  

Energy Technology Data Exchange (ETDEWEB)

In a retrospective study of 21 patients, in whom the acetabular fractures were suspected on initial radiographs, we compared and analysed the computed tomographic findings and plain radiographic findings. The results were as follow: 1. In patients with multiple trauma, no further change in position was required during CT examinations. 2. CT showed intraarticular loose bodies, which were invisible on plain radiographs. 3. CT was useful in detecting the fractures of acetabular rims, medial wall of acetabulum, and femoral head. 4. CT permitted better evaluation of shape, extent, and degree of separation of fracture fragments. 5. CT was helpful in detecting the associated fractures and soft tissue injuries. 6. CT also demonstrated the adequacy of reduction, the position of metallic fixation devices, and the presence or absence of remaining intraarticular osseous fragments after surgery.

1986-04-15

10

The impact of the America's Cup on Fremantle Hospital.  

UK PubMed Central (United Kingdom)

The first defence of the America's Cup outside of the USA took place off Fremantle, Western Australia, between October, 1986 and February, 1987. Fremantle Hospital, the nearest hospital to the marinas,...Full Text Available

1989-12-01

11

A newly designed big cup nitinol stent for gastric outlet obstruction  

UK PubMed Central (United Kingdom)

AIM: To find out whether a newly designed big cup nitinol stent is suitable for treatment of patients with gastric outlet obstruction resulting from gastric cancer.METHODS: The new stent is composed...Full Text Available

2010-09-07

12

EFFECTS OF SHIELDING ON PROPERTIES OF EDDY ...  

Science.gov (United States)

... Accession Number : ADD323869. Title : EFFECTS OF SHIELDING ON PROPERTIES OF EDDY CURRENT PROBES WITH FERRITE CUP CORES. ...

1986-08-01

13

EDDY CURRENT SIZING OF CASE DEPTH IN BEARING ...  

Science.gov (United States)

... HARDENED CUP AND CARBURIZED AND HARDENED CORES HAVE BEEN PROFILED USING 2 TYPES OF EDDY CURRENT PROBES. ...

1986-07-01

14

Estimation of throughfall erosivity in a highly diverse forest ecosystem using sand-filled splash cups  

British Library Electronic Table of Contents (United Kingdom)

Sand-filled splash cups were used to study the erosive power of rainfall and throughfall in the humid subtropics of Southeast China. The splash cup measurements yielded precise and reproducible results under both open field conditions and forest vegetation. The splash cups were exposed to specific forest stands of different ages and to selected species (Schima superba, Castanopsis eyrei, Daphniphyllum oldhamii, Lithocarpus glaber) in the Gutianshan (???) National Nature Reserve (GNNR). The results of the measurements under forest vegetation show that the erosive power of throughfall drops to be 2.59 times higher compared to the open field. This accentuates the importance of shrub, herb and litter layers in forest ecosystems to protect the soil against erosion. Coalescing drops from leaves ...

2010-01-01

15

EUROPEAN SPACE AGENCY Extension of the SOHO Mission  

Science.gov (United States)

closure of the BISON network, GOLF and VIRGO will remain the only instruments ...... Faraday Cup solar wind instrument as described in Ipavich et al (1998). ...

16

Radon concentration measurement in dwellings in Belgrade  

International Nuclear Information System (INIS)

The results of the radon concentration measurements in dwellings in Belgrade were shown in this paper. The measurements were done using long term method with diffusion cups equipped with solid state nuclear track detector LR-115-II or CR-39. (author).

17

Localisation of glycoproteins and glycosaminoglycans during early eye development in the macaque.  

UK PubMed Central (United Kingdom)

The composition of the extracellular matrix (ECM) was examined in the developing lens and optic cup (stages 11-16) of the long-tailed monkey (Macaca fascicularis) using peroxidase immunocytochemistry....Full Text Available

1995-02-01

18

Indoor radon concentration measurements by using SSNTD  

International Nuclear Information System (INIS)

In this paper, some results of the indoor radon concentration measurements are presented. Kodac track detectors LR 115, bare and in a cup were used for these measurements. Average winter/summer ratio was determined for the town of interest. (author). 5 refs, 1 fig., 1 tab.

19

Dual mobility cup reduces dislocation rate after arthroplasty for femoral neck fracture  

UK PubMed Central (United Kingdom)

BackgroundHip dislocation after arthroplasty for femoral neck fractures remains a serious complication. The aim of our study was to investigate the dislocation rate in acute femoral...Full Text Available

20

Coffee People Organic K-Cups for Keurig Brewers (Pack of 50): Amazon.com: Grocery & Gourmet Food  

Wastenet

...options box during checkout as this item typically ships in its own packaging. 3 new from $29.95 Your Favorite Coffee, ...

 
 
 
 
21

Biographical Sketch: John Royal Moore, MD 1899?1988  

British Library Electronic Table of Contents (United Kingdom)

This biographical sketch on John R. Moore corresponds to the historic text, The Classic: Cartilaginous-cup Arthroplasty in Ununited Fractures of the Neck of the Femur (1948), available at DOI External Reference Not Shown .

2011-01-01

22

Results of in-house cone-cup testing of low to high temperature SPF-alloys  

Energy Technology Data Exchange (ETDEWEB)

Material testing of SPF-sheet is usually done with coupon hot tensile testing. The optimum range of strain rates is determined with stepped strain tests. To overcome the problem of very few available testing facilities and time consuming and costly procedure, cone cup testing has been developed since long. This test can be generated directly in the workshop, no machining of samples is necessary and it is very much related to the real SPF-process. The analysis of suitable temperature and strain rate is done by simple measurement of resulting cone height. This paper describes a unique and novel variant of the above mentioned baseline design. It provides on-line data of the actual status of the cone cup forming resulting from the applied, constant pressure. Strain rate variations as a result from texture or from the alloy-related behaviour is detectable. Thinning and ''hardening'' behaviour of different alloys ...

2004-07-01

23

Indoor thoron and radon concentration measurements with passive cup monitors  

International Nuclear Information System (INIS)

A new type of passive integrating cup monitors was developed to measure indoor thoron("2"2"0Rn) and radon("2"2"2Rn) concentrations. By placing a pair of cup monitors with different size a air exchange windows in the same place during a sufficient period of time the concentrations of both gases can be assessed from the alpha track densities on the CN films of the two monitors. The lower detection limit with a 3 months measurement period is for "2"2"0Rn 26.1 Bq*m"-"3 and is for "2"2"2Rn 6.1 Bq*m"-"3. Radon-220 and "2"2"2Rn concentrations have been measured in about 20 different types of dwellings around the Nagoya area with these monitors. The results suggest that the "2"2"0Rn concentrations were rather high in traditional Japanese dwellings made of a timber frame and mud. (orig.). (4 refs., 4 figs.).

1993-07-04

24

Chemical and physical change of packaging materials for food by gamma-ray irradiation  

International Nuclear Information System (INIS)

Recently, foods are often exposed to radiation under packed states with various wrapping materials. In this study, the effects of #gamma#-ray radiation were investigated on the additives in wrapping materials on the market. 10 - 50 kGy #gamma# radiation was irradiated to samples under sealed condition in a glass-ware. Polyethylene bag and wrapping film, polypropylene wrapping film, cup and sheet, and polystyrene cup were used as samples. And the additives in these materials were analyzed by GC/MS to evaluate the radiation effects on them. The irradiation was found to induce rapid degradation of antioxidants, especially, Irgafos 168. Some fatty acid amides used as a lubricant and a plasticizer, DBP were also reduced, but not aliphatic hydrocarbons. However, all polystyrene products used in this study included no additives. The contents of styrene dimer and trimer in those wrapping materials were not changed by #gamma#-irradiation. (M.N.)

1999-02-01

25

Studies on scintigraphic findings after femoral head replacement  

Energy Technology Data Exchange (ETDEWEB)

Femoral head replacement was performed for femoral neck fracture or femoral head necrosis on 36 hips of 34 patients on whom Tc-99m MDP scintigraphy was done for analysis of radioisotope uptake around the prosthesis. In the cases with satisfactory clinical course after replacement surgery the uptake was high in the area between the prosthesis and the trochanter, in the area of the stem tip of the prosthesis and in the acetabular area. The high uptake decreased gradually and reached a normal level by 8 months after surgery. The cases with no decrease of high uptake by 8 months after surgery were considered to have had an eventful postoperative course associated with some complication such as infection, fracture, loosening etc. Tc-99m MDP scintigraphy was useful for early detection of complications and to evaluate progress of the operated patients. (author)

2001-03-01

26

Koyo engineering journal, No. 147, April 1995. Special issue on automotive bearings and applicable products  

Energy Technology Data Exchange (ETDEWEB)

Special Issue on Automotive Bearings and Applicable Products; Reports include Performance of Ceramic Cam Roller Follower for Automotive Engine; Performance of Drawn Cup Needle Roller Bearing for Propellershaft; Plastic Bearing Retainer for High Temperature Oil Lubrication; Bearing Device for Vehicle Axle; and Flush Mounting Type Programmable Cam Switches.

1995-12-31

27

Hierarchical Kohonenen net for anomaly detection in network security.  

Science.gov (United States)

A novel multilevel hierarchical Kohonen Net (K-Map) for an intrusion detection system is presented. Each level of the hierarchical map is modeled as a simple winner-take-all K-Map. One significant advantage of this multilevel hierarchical K-Map is its computational efficiency. Unlike other statistical anomaly detection methods such as nearest neighbor approach, K-means clustering or probabilistic analysis that employ distance computation in the feature space to identify the outliers, our approach does not involve costly point-to-point computation in organizing the data into clusters. Another advantage is the reduced network size. We use the classification capability of the K-Map on selected dimensions of data set in detecting anomalies. Randomly selected subsets that contain both attacks and normal records from the KDD Cup 1999 benchmark data are used to train the hierarchical net. We use a confidence measure to label the clusters. Then we use the test set from the ...

2005-04-01

28

Spatial and angular characteristics of microsecond negative-ion beams in a magnetically insulated diode  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the design of a high-voltage negative ion source based on a magnetically insulated diode and generating microsecond pulses. Plane an cylindrical cathodes have been tested. The spatial and angular distributions of negative ions in the beam have been measured. The content of negative ions with different masses in the beam are given. The ion current density measured by a Faraday cup was up to 1 A/cm{sup 2} for the radial beam and 30-40 A/cm{sup 2}.

1995-10-01

29

Human bone matrix gelatin as a clinical alloimplant. A retrospective review of 160 cases.  

Science.gov (United States)

Bone matrix gelatin, prepared by sequential chemical treatment including decalcification with 0.6 N hydrochloric acid [9], was used as an alloimplant for the treatment of benign bone tumours, tumorous conditions of bone, acetabular dysplasia, delayed union, traumatic bone defects and other disorders. The bone matrix gelatin implanted into bone defects was incorporated successfully in 98% of implantations, excluding cases of infection, tumour recurrence and recurrence of tumorous conditions. The material was also implanted into ten bone sites as an onlay but in five it was resorbed without new bone formation. The incorporation of the bone matrix gelatin into the recipient bed was completed from 6 to 33 months (average 14.9 months) after implantation. Wound infection complicated 5 of 165 implantations (3%) in previously uninfected sites. Low grade fever persisting after the tenth post-operative day (a probable sign of immunological reaction) occurred in 4 of 160 ...

1985-01-01

30

Waste and dust utilisation in shaft furnaces  

Energy Technology Data Exchange (ETDEWEB)

Wastes and dusts from steel industry, non-ferrous metallurgy and other branches can be utilised e.g. in agglomeration processes (sintering, pelletising or briquetting) and by injection into shaft furnaces. This paper deals with the second way. Combustion and reduction behaviour of iron- and carbon-rich metallurgical dusts and sludges containing lead, zinc and alkali as well as other wastes with and without pulverised coal (PC) has been studied when injecting into shaft furnaces. Following shaft furnaces have been examined: blast furnace, cupola furnace, OxiCup furnace and imperial-smelting furnace. Investigations have been done at laboratory and industrial scale. Some dusts and wastes under certain conditions can be not only reused but can also improve combustion efficiency at the tuyeres as well as furnace performance and productivity.

2005-07-01

31

Role of cerebrospinal fluid pressure in the pathogenesis of glaucoma  

British Library Electronic Table of Contents (United Kingdom)

Abstract. The pathogenesis of normal (intraocular) pressure glaucoma has remained unclear so far. As hospital-based studies showed an association of normal-pressure glaucoma with low systemic blood pressure, particularly at night, and with vasospastic symptoms, it has been hypothesized that a vascular factor may play a primary role in the pathogenesis of normal-pressure glaucoma. That assumption may, however, be contradicted by the morphology of the optic nerve head. Eyes with normal-pressure glaucoma and glaucomatous eyes with high-intraocular pressure can show a strikingly similar appearance of the optic nerve head, including a loss of neuroretinal rim, a deepening of the optic cup, and an enlargement of parapapillary atrophy. These features, however, are not found in any (other) vascula...

2011-01-01

32

MR findings in cases of suspected impacted fracture of the femoral neck  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate MR imaging of the hip in patients with a clinically suspected impacted fracture of the femoral neck in cases where conventional plain films show negative or equivocal findings. Material and Methods: Twenty-seven such patients were prospectively examined by MR imaging with a 1.0 T unit, within 24 hours of admittance to hospital. A coronal T1-weighted turbo spin-echo sequence (n=27), and a coronal STIR sequence (n=25) or a coronal T2-weighted turbo spin-echo fast saturation sequence (n=2) were used. The evaluations were made by 2 radiologists with experience in musculoskeletal radiology. Results: There were 6 patients with a petrochanteric fracture, 2 without and 4 with slight displacement. Five patients had an impacted fracture of the femoral neck, and 3 had a fracture of the superior pubic bone. Of 2 patients with advanced arthrosis, i had an impacted femoral neck fracture and the other a nondisplaced intertrochanteric fracture. There was 1 patient who had ...

1997-09-01

33

The feasibility study of hot cell decontamination by the PFC spray method  

International Nuclear Information System (INIS)

The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research Institute (KAERI) is ...

2008-01-01

34

Production of intense negative ion beams in magnetically insulated diodes  

Energy Technology Data Exchange (ETDEWEB)

Production of intense negative ion beams in magnetically insulated diodes was studied in order to develop an understanding of this process by measuring the ion-beam parameters as a function of diode and cathode plasma conditions in different magnetically insulated diodes. A coral diode, a racetrack diode, and an annular diode were used. The UCI APEX pulse line, with a nominal output of 1MV, 140kA, was used under matched conditions with a pulse length of 50 nsec. Negative-ion intensity and divergence were measured with Faraday cups and CR-39 track detectors. Cathode plasma was produced by passive dielectric cathodes and later, by an independent plasma gun. Negative-ion currents had an intensity of a few A/cm{sup 2} with a divergence ranging between a few tenths milliradians for an active TiH{sub 2} plasma gun and 300 milliradians for a passive polyethelene cathode. Negative ions were usually emitted from a few hot spots on the cathode surface. These hot spots are ...

1988-01-01

35

Numerical Modeling of Magnesium Alloy Sheet Metal Forming at Elevated Temperature  

International Nuclear Information System (INIS)

The development of light-weight vehicle is in great demand for enhancement of fuel efficiency and dynamic performance. The vehicle weight can be reduced effectively by using lightweight materials such as magnesium alloys. However, the use of magnesium alloys in sheet forming processes is still limited because of their low formability at room temperature and the lack of understanding of the forming process of magnesium alloys at elevated temperatures. In this study, uniaxial tensile tests of the magnesium alloy AZ31B-O at various temperatures were performed to evaluate the mechanical properties of this alloy relevant for forming of magnesium sheets. To construct a FLD (forming limit diagram), a forming limit test were conducted at temperature of 100 and 200 deg. C. For the evaluation of the effects of the punch temperature on the formability of a rectangular cup drawing with AZ31B-O, numerical modelling was conducted. The experiment results indicate that the ...

2007-05-17

36

Maternal consumption of coffee and tea during pregnancy and risk of childhood ALL: results from an Australian case?control study  

British Library Electronic Table of Contents (United Kingdom)

Objectives To investigate whether maternal coffee and/or tea consumption during the last 6?months of pregnancy was associated with risk of childhood ALL. Methods Data on coffee and tea drinking during pregnancy from 337 case mothers and 697 control mothers were analyzed using unconditional multivariable logistic regression. A meta-analysis of our findings with those of previous studies was also conducted. Results There was little evidence of an overall association between maternal coffee consumption and risk of ALL: OR 0.89 (95% CI 0.61, 1.30), although there was some suggestion that higher levels of intake might increase the risk in children of non-smoking mothers: OR for 2+ cups/day?=?1.44 (95% CI 0.85, 2.42); this was supported by our meta-analysis. Risk was also elevated among cases wi...

2011-01-01

37

Coffee and tea consumption and endometrial cancer risk in a population-based study in New Jersey  

British Library Electronic Table of Contents (United Kingdom)

We evaluated the role of tea and coffee and substances added (sugar/honey, creamers, and milk) on endometrial cancer risk in a population-based case?control study in six counties in New Jersey, including 417 cases and 395 controls. Multivariate odds ratios (OR) and 95% confidence intervals (CI) were computed using unconditional logistic regression. There was a moderate inverse association with coffee consumption, with an adjusted OR of 0.65 (95% CI: 0.36?1.17) for women who reported more than two cups/day of coffee compared to none. Tea consumption appeared to increase risk (OR: 1.93; 95% CI: 1.08?3.45), but after including the variables sugar/honey and cream/milk added to tea in the model, the risk estimate was attenuated and no longer statistically significant (OR: 1.77; 95% CI: 0.96?3.2...

2010-01-01

38

The high-sensitive magnetic levitated electrode ionization chamber of the noncontacting type  

Energy Technology Data Exchange (ETDEWEB)

There are two types of ionization chamber using magnetically levitated electrode: one is that by Tanaka et al. and the other, by authors'. The latter lacks the sensitivity relative to the former and thereby to solve the problem, authors made an improvement so that the electrode charge could be readout by noncontact after the leviated electrode was electrified by noncontact for an interval. This new type ionization chamber made it possible to measure the quite low dose radiation with stability and high sensitivity. Actually, the electrode was suspended by the teflon thread fixed on the steel cup levitated magnetically in the ionization chamber of which wall was covered by Al and equipped with an electrostatic charger for the electrode by noncontact. After measurement, the electrode was moved in the Faraday cage placed under the chamber to readout the voltage. For operation conditions of the apparatus, observation was done on the relationship between ...

1999-09-01

39

Palliative hepatic intraarterial chemotherapy (HIC) using a novel combination of gemcitabine and mitomycin C: results in hepatic metastases  

International Nuclear Information System (INIS)

To evaluate repeated hepatic intraarterial chemotherapy (HIC) as a palliative treatment option for unresectable cholangiocarcinoma and liver metastases of various origins that were progressive under systemic chemotherapy. Between 2002 and 2006, 55 patients were treated in 4-week intervals (mean five sessions). Combined gemcitabine/mitomycin was administered intraarterially within 1 h. Tumor response was evaluated after the third session according to RECIST. Treated tumor entities were colorectal carcinoma (CRC) (n = 12), breast cancer (BC) (n = 12), cholangiocarcinoma (CCC) (n = 10), pancreatic (n = 4), ovarian (n = 3), gastric, cervical, papillary (each n = 2), prostate, esophageal carcinoma, leiomyosarcoma (each n = 1), cancer of unknown primacy (CUP) (n = 5). All patients tolerated the treatment well without any major side effects or complications. In total, there were 1 complete response (CR), 19 partial responses (PR), 19 stable (SD) and 16 progressive ...

2008-03-01

40

Halogens for negative ion beams and ion-ion plasmas  

International Nuclear Information System (INIS)

Negative ions have attractive features as drivers for inertial confinement fusion, because they will avoid electron cloud effects, and could be efficiently photodetached to neutrals after the final focus, which could also be beneficial in heating warm dense matter targets. The halogens have large electron affinities, and thus should be able to produce high current densities of relatively robust negative ions. Recent experiments comparing chlorine beams to argon beams using the same source, extraction optics, and diagnostics have demonstrated that Cl"- beams can be produced with similar emittance to Ar"+ beams, and with about 34 the current density from the same configuration. The observed effective beam temperature of about 13eV, and the similarity of current densities show that negative halogen beams can meet the current density and emittance requirements of heavy ion fusion. The near equivalence of the Cl"- and Cl"++Cl_2"+ current densities reaching the Faraday ...

2007-07-01

 
 
 
 
41

Field investigation of a wake structure downwind of a VAWT in a windfarm array  

Energy Technology Data Exchange (ETDEWEB)

The effects of upwind turbine wakes on the performance of a FloWind 17-m VAWT were investigated through a series of field experiments conducted at the FloWind windfarm on Cameron Ridge, Tehachapi, California. The field experiment was conducted within a VAWT array consisting of more than nine VAWTs with separations 3D crosswised by 8D downwind (where D is the turbine diameter) in a staggered configuration. The array is the upwind three rows of VAWTS in a total of six rows that are on top of the Cameron Ridge plateau. The terrain features in the vicinity are reasonably regular, with an upslope of 7 deg on the average; however, several local irregularities are present. The annual hourly averaged wind speed exceeds 8 m/s at the site. The wind field and the power-outputs of nine turbines within the array were measured with wind sensors and power transducers. Nine Gill propeller and 18 Maximum cup anemometers and one direction sensor were mounted on portable and stack-up ...

1987-10-01

42

Effect of acidic fluoride solution on beta titanium alloy wire.  

Science.gov (United States)

The interaction between acidic fluoride solution and beta titanium alloy was investigated to explore the changes that occur in beta titanium alloy by fluoride-containing acetic acid solutions. For this, alloy crystal structure, tensile strength, and elements released from the alloy wires were determined using four solutions (0.05%/pH 6, 0.05%/pH 4, 0.2%/pH 6, and 0.2%/pH 4) for 1 or 3 days. The immersed wire did not form any identifiable new crystal structure compared with the as-received wire. The tensile strength of the immersed wires was significantly reduced compared to the as-received wires in the test solutions if the period of immersion increased from as-received to 3 days. The fractured area of the immersed wire was reduced compared to the as-received one. The dimple pattern at the inner part and a cup-cone morphology at the outer part of the fractured wires were similar in both as-received and immersed wires. After a 3-day immersion, the amount of the ...

2005-05-01