The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For ...
Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).
In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gasdischarges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two ...
The pure xenon dc positive column discharge has been characterized for various xenon pressures, currents, and dischargetube radii. The absolute output at the 147 nm resonance transition has been measured using two independent techniques to yield the radiant emittance at 147 nm (power per unit surface area). The efficiency of 147 nm production is obtained by combining the measured radiant emittance with the measured electrical power per unit length deposited in the gas. The radiant emittance and the efficiency are the two principle figures of merit for characterizing the discharge as a source of VUV radiation. It is observed that the trends in efficiency and radiant emittance change substantially when the discharge transitions from two-step electron impact excitation/ionization at higher pressures to single-step electron impact ionization at lower pressures. ...
Corona discharge has been investigated for the treatment of off-gases arising from nuclear fuel reprocessing operations, in particular Dissolver off-Gases (DOG). Results are presented of studies carried out on single tube, wire-in-tube experimental rigs to examine the behaviour of molecular iodine, organic iodine and oxides of nitrogen (NOx). The effect of corona current, gas residence time, electrode configuration, oxygen concentration and moisture content are discussed. Decontamination Factors (DF's) of greater than 104 (> 99.99% removal) have been achieved for both molecular and organic iodine. Efficient NOx removal has also been demonstrated. Moisture and NOx both interfere with iodine removal above certain concentrations. To overcome this a two stage corona system has been developed consisting of a primary continuously irrigated corona unit followed by a dehumidifier prior to a secondary dry ...
By placing a discharge or 'dump' tube across an exploding bridgewire load, it is possible to by-pass the electrical energy and terminate the explosion of the wire. The dump tube is triggered by a signal derived from the energy removed from the storage cap...
The isotopic enrichment of copper ions in a positive column Cu-Nu discharge using optogalvanic excitation is analyzed with a rate equation model With excitation at 510.6 nm, the fraction of the ions belonging to the 63-amu isotope of copper is enriched relative to the neutral abundance. Enrichment as large as 10% is calculated when the initial abundance of the neutral isotope is small (< or =0.1) and the discharge current density is large (> or =75 mA/cm/sup 2/). The degree of enrichment is examined as a function of the initial abundance, discharge current, the rate of charge exchange, and the diameter of the dischargetube.
The Coal Fired Combined Cycle (CFCC) power system thermodynamic cycle is illustrated schematically. Pressurized air supplied at the discharge of gas turbine compressors is ducted to the pressure vessel of pressurized, fluidized-bed, combustor-steam generator modules. The air is introduced in parallel to the beds, entering through distribution grids beneath each bed. Steam generation tubes are buried within the beds and are also arranged as membrane tube walls enclosing the four sides. Crushed coal (1/4 inch x 0) is pneumatically fed at locations just above the air inlet grids at the bottom of each bed. Dolomite is similarly fed to the individual beds. The coal is burned at a temperature below the ash fusion point. Sulfur is removed in the fluid beds through reaction of the SO/sub 2/ with CaCO/sub 3/ and O/sub 2/ to form solid CaSO/sub 4/ and CO/sub 2/ gas. The combustion gases leave ...
A shock wave appears when the release of accumulated energy is instantaneous. For instance, it accompanies gunpowder explosion, electric discharge, laser beam convergence, collision of high-speed objects, release of high-pressure gas, and supersonic flight. The shock wave research center of Institute of Fluid Science, Tohoku University, is engaged in researches to elucidate the basics of various shock wave phenomena and to apply the fruit to engineering, science, and medicine. In this report, some examples of recent application studies at the center are described, and the trend of shock wave researches in the future is introduced. The ultimate state of the stagnation point of a nozzle flow simulating a reentry into the atmosphere is produced by shock wave compression in a free piston shock tube which is a ground-borne experimental apparatus. Los Alamos National Laboratory, U.S., succeeded in generating metallic hydrogen of ...
The high pressure discharges (pulsed or D C corona, barrier, gliding and the others), have been studied both experimentally and theoretically as sources of low temperature plasma for pollution control technologies. The potential of electrical discharge methods has been demonstrated for the decomposition of many types of VOC. The air or oxygen are used as a feed gas in which pollutant is diluted. The ozone production in air or oxygen in such discharges is also discussed
Results are described of a study and of the characteristics of sources of a non-equilibrium gas-discharge plasma. The plasma generators considered include glow, high frequency, and arc discharge generators. Thermodynamic, ionic, and electronic processes occurring in the plasmas are evaluated.
The present article studies the electret state of polymers when moving through an alternating-current corona discharge plasma and investigates means for the determination of the transition of the polymeric material from the initial state of the electret when the corona-displaying voltage is increased.
The characteristics of diffuse glow discharges in pure argon and the Ar + 1%N2 mixture at pressures of 2?80 Torr were studied experimentally and numerically. The discharge operated in a molybdenumglass tube with an inner diameter of 2.8 cm and interelectrode distance of 75 cm. The current-voltage characteristic of the discharge and the populations of the N2(B3? g ) and N2(C3? u ) states were measured. It is shown that, at relatively low pressures (P 15 Torr), the current-voltage characteristic of a discharge in the mixture lies lower than that in pure argon. As the pressure increases, the effect of the reduction in the discha...
High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.
Ozone formation by a pulse positive corona discharge generated in the gas phase between a planar high voltage electrode made from reticulated vitreous carbon and a water surface with an immersed ground stainless steel plate electrode was investigated under various operating conditions. The effects of gas flow rate (0.5-3 litre min"-"1), discharge gap spacing (2.5-10 mm), applied input power (2-45 W) and gas composition (oxygen containing argon or nitrogen) on ozone production were determined. Ozone concentration increased with increasing power input and with increasing discharge gap. The production of ozone was significantly affected by the presence of water vapour formed through vaporization of water at the gas-liquid interface by the action of the gas phase discharge. The highest energy efficiency ...
With the help of heat balance equation and high temperature thermodynamic function, the calibration relation of jet temperature with discharge power, gas flow rate was obtained for nitrogen thermal plasma. It was shown that the results were agreed with the principle of similarity. The jet temperature was a function of Peff/f, instead of a general two variables function of Peff and f, which were effective discharge power and working gas flow rate, respectively. A related discussion has been given; it will be referable to thermal plasma applications. (authors)
Pulsed DC-plasma nitriding has been applied to form nitride layer having only a diffusion layer. The discharge current with the variation of discharge gases is proportional to the intensity of N{sub 2}{sup +} peak in optical emission spectroscopy during the plasma nitriding. The discharge current, microhardness in surface of substrate and depth of nitride layer increased with the ratio of N{sub 2} to H{sub 2} gas in discharge gases. When the ratio of N{sub 2} to H{sub 2} is lower than 60% in the discharge gases, high microhardness value of 1100Hv nitride layer which contains no compound layer has been formed. (author). 20 refs., 6 figs., 1 tab.
We have studied the efficiency of ozone production by pulsed positive corona discharge in coaxial wire-cylinder geometry at atmospheric pressure. A corona discharge was generated by short (#approx#150 ns) high voltage pulses applied between a silver coated copper wire anode and stainless steel cylinder cathode in synthetic air. A pyrex probe and Teflon tube was used for collecting discharge products and an ozone concentration was monitored outside of the discharge chamber by a non-dispersive UV absorption technique. The production of ozone was investigated as a function of energy density (10"-"4-3x10"-"1 Wh l"-"1) delivered to the discharge volume by combining the discharge frequency (0.1-10 Hz) and airflow rate (1-32 l min"-"1). From ozone concentration measurements we have evaluated the ozone production, yield and production energy cost. ...
Doped ultrafine silicon dioxide powder with a narrow particle size distribution was obtained by RF discharge-stimulated dichlorosilane (SiH2C) oxidation at a low pressure using isobutylene as the combustion inhibitor and chromium hexacarbonyl (Cr(CO)6) as the dopant. The formation and morphology of the ultrafine particles are governed by the parameters of the RF discharge and by the chemical mechanism of the combustion reaction yielding the aerosol. Submicron-sized filamentous carbon structures can be obtained by isobutylene decomposition under spark discharge conditions in the presence of a molybdenum metal catalyst.
The tube bundle arrangement is suitable as reheating section of a steam generator in combination with a gas-cooled reactor. For any high-temperature section with a straightline type tube bundle, there is one inlet and one outlet collecting main; these two are arranged one opposite to the other and diametrically to the tube bundle. There are a number of lines from the inlet collecting main to the outlet collecting main; these lines are arranged axially one on top of the other and run around the tube bundle helically several times. (GL) 891 GL/GL 892 MB.
In this article, the results of low-current gas-discharge plasma generator investigations carried out by a group of scientists from the Kazan' Aviation Institute are presented. When considered necessary, the results are compared with the data obtained by other authors. The basic configurations and theoretical calculation peculiarities of plasma generators are described. The electrical, thermal and energy characteristics of discharges in gas flows, as well as summarised empirical formulae and experimental data necessary for calculations and design of plasma devices are presented. (author)
A physical explanation is given for the positive differential voltage-current characteristic seen at low current in weakly ionized, low-pressure positive column discharges in argon/mercury gas mixtures. {copyright} {ital 1996 The American Physical Society.}
The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.
We propose a method of plasma production by capacity-coupled multidischarge (CCMD) at atmospheric pressure. The discharge gaps in the CCMD consist of a common electrode and a number of compact electrodes (CCE) which are directly coupled with small capacitors for quenching the discharge. A simple CCE structure is provided by a cylindrical capacitor, the inner conductor of which is used as a gap electrode. A short pulse discharge is observed to appear homogeneously at each CCE. A charge transfer for the single-pulsed discharge is 10-100 times as large as that of the conventional dielectric barrier discharge. A high efficiency of ozone production has been confirmed in the CCMD using O_2 gas. A device configuration of the CCMD is quite flexible with respect to its geometrical shape and size. The CCMD could be used to produce plasmas for various kinds of industrial ...
This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmission lines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.
A flowing carbon dioxide laser was operated at low pressures up to 4 torr. Excitation of the laser was provided using various combinations of direct current (DC), pulsed microwave, and continuous wave (CW) microwave excitation. The microwaves were in the 2.45 GHz band and were coupled into the gas using a slow-wave interdigital transmission line. Laser output of 25 milliwatts (mw) was achieved using a DC discharge only. A combination of a DC discharge and pulsed microwaves doubled the output and resulted in some modulation. Changing the laser gas mixture and pulsed microwave field characteristics allowed some flexibility in the modulation. Lasing was not achieved with excitation from the CW microwaves alone due to the formation of localized discharges. Using pulsed microwaves to sustain the discharge and CW microwaves to pump the laser, a quasi-CW output of 55 ...
The paper deals with a model in which the motion of a gas in plasma accerators and high-curent discharges in the present of a skin effect is treated as expulsion by a 'magnetic piston' under the action of surface current flow. Specifically examined is the situation where the initial gas pressure is negligible in comparison with the magnetic pressure, and the motion of the gas may be treated as a self-simulating one. A system of hydrodynamic equations of the problem is derived and integrated by Adam's method. Results are plotted and discussed.
During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 ...
Investigatins into the welding of alloy 800 at the Reactor Fuel Element Laboratories, Springfields, commenced about three years ago following an extended development programme on tube to tube plate welding of low alloy and stainless steels for the Prototype Fast Reactor. The techniques and approach developed for critical fuel element welding applications had proved equally suitable for the precision welding requirements on the much heavier sections of heat exchangers. It had been demonstrated that the same control of weld quality and profile could be achieved with consistency and the permissible range of critical parameters could be readily defined. Because of this, development work was continued to include other materials, such as alloy 800, which might be of potential use. The tungsten inert gas (T.I.G.) arc welding process is used, and the equipment, including the control system, is described. Tube ...
This paper describes detection of electro-discharged machine (EDM) defects in magnetic steam generator (SG) tubes of Monju fast breeder reactor (FBR). The EDM defects are located under support plate (SP), on the outer tube surface and they are detected by a remote field eddy current probe. Using the experimental measurements and a multi frequency algorithm, the defect signal can be extracted from the SP signal. The parameters of the multi-frequency algorithm were calculated by comparing SP measurements with two-dimensional finite element simulations (FEM). (author)
The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the dischargetube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...
We have demonstrated that, with simple pH adjustment, volatile drugs such as methamphetamine, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA), ketamine, and valproic acid could be analyzed rapidly from raw biofluid samples (e.g. urine and serum) without dilution, or extraction, using atmospheric pressure ionization. The ion source was a variant type of atmospheric pressure chemical ionization (APCI) that used a dielectric barrier discharge (DBD) to generate the metastable helium gas and reagent ions. The sample solution was loaded in a disposable glass pipette, and the volatile compounds were purged by nitrogen gas to be reacted with the metastable helium gas. The electrodes of the DBD were arranged in such a way that the generated glow discharge was confined within the discharge tub...
The purpose of this rulemaking is to amend the effluent limitations guidelines and standards for the control of discharges of certain pollutants associated with the use of synthetic-based drilling fluids (SBFs) and other non-aqueous drilling fluids in portions of the Offshore Subcategory and Cook Inlet portion of the Coastal Subcategory of the Oil and Gas Extraction Point Source Category. These proposed limitations apply to discharges or effluent generated when oil and gas wells are drilled using SBFs or other non-aqueous drilling fluids (collectively referred to simply as SBFs) in coastal and offshore regions in locations where drilling wastes may be discharged.
A gas tracer technique based on carbon monoxide and a commercial automotive exhaust gas analyser has been applied to wind tunnel models of waterjet propulsion systems intakes. The post-processing and interpretation of the carbon monoxide concentration signals has yielded high resolution measurements of the bounding ingestion stream-tubes. (orig.) With 3 figs., 1 tab., 8 refs.
The pipelines is provided for gases, particluarly helium, at temperature of about 1000/sup 0/C (pressure about 40 bar) and is used as the connection be tween a gas cooled high temperature reactor and a heat load. The pipe consists of a temperature-resistant inner tube, which is composed of several pipe sections, which are supported on ball bearings, and a gas tight pressurised outer tube. There are supports and insulation between the two tubes. The sub-claims concern fixing of and bearings for the pipe sections. The description is very detailed and supplemented by drawings.
This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in HTR-10. The wall ...
The phenomenon of runaway electrons (REs) at high values of the ratio field intensity/gas number density {ital E}/{ital N} and {ital N} up to the Loshmidt number {ital N}{sub {ital L}}{approx_equal}2.7{times}10{sup 19} cm{sup {minus}3} is described. REs are shown to govern the breakdown and discharges at such condition. {copyright} {ital 1996 American Institute of Physics.}
Plasma nitriding in glow discharge is a process of modifying surface properties of a material by which surface hardness, corrosion resistance, fatigue strength etc. of a material can be improved
In this paper we study different effects of excited molecules on swarm parameters, electron energy distribution functions and gasdischarge modeling. First we discuss a possible experiment in parahydrogen to resolve the discrepancy in hydrogen vibrational excitation cross section data. Negative differential conductivity (NDC) is a kinetic phenomenon which manifests itself in a particular dependence of the drift velocity on E=N and it is affected by superelastic collisions with excited states. A complete kinetic scheme for argon required to model excited state densities in gasdischarges is also described. These results are used to explain experiments in capacitively and inductively coupled RF plasmas used for processing. The paper illustrates the application of atomic and molecular collision data, swarm data and the theoretical techniques in modeling of gas ...
This report is devoted to the investigation of the influence of electron collisions and radial non-uniformity of plasma density on phase characteristics, spatial attenuation and wave field structure of slow symmetric electromagnetic waves that propagate along cylindrical waveguide structure. It has been shown that collision rate and radial non-uniformity of plasma density for various parameters of waveguide structure and dielectric affect essentially on the wave characteristics and consequently, on the parameters of gasdischarge that is sustained by this wave. The results obtained are of large importance for the construction of the theory of gasdischarges that are sustained by the surface electromagnetic waves.
A study is made into microhardness and structure of coatings on various system steels (37G2S, 25Kh5M, R6M5), obtained by ion nitriding in a low pressure (10"-"1 Pa) arc discharge plasma. A comparison of properties is accomplished for steels nitrided in an arc gasdischarge and in a furnace. It is stated that ion-plasma nitriding in an arc gas plasma generator is an efficient method of alloy steels hardening which allows changing the structure and increasing the hardness of a surface layer up to rather great depth
Vacuum arc with cathode spots on the cold electrode is widely used as a plasma generator in a such kind of devices like metal ion sources, plasma cathode electron guns, thing films deposition facilities and others. Most vacuum arc devices utilize a high voltage discharge across an insulator surface to provide a trigger plasma which in turn initiates the main arc discharge. Operation of vacuum arc in a repetitively pulsed mode required a stable triggering system for the long time. But with a discharge across the insulators the number of stable pulses is limited by 100,000 or little bit more. The better method for vacuum arc ignition is low pressure discharge. As shown in this paper it is possible to increase the lifetime of the ignition system in 10 times at least, but negative characteristic of this system is a relatively high pressure (about 0.1 mtorr). In some kinds of vacuum arc applications it is ...
A brief comparative review of possible mercury free fluorescent lighting technologies is presented, including rare-gas positive column discharges, molecular discharges, and dielectric barrier discharges. Detailed experimental results on xenon positive column discharges will then be considered. In order to judge whether xenon-based discharges are a viable UV source it is necessary to measure the radiant emittance (power per unit area) for the vacuum ultraviolet (VUV) resonance xenon emission at 147 nm. Two techniques to determine the VUV radiant emittance have been developed and applied to xenon discharges. One method combines the measured resonance level density using absorption spectroscopy and a calculation of the trapped decay rate for the resonance radiation to arrive at the radiant emittance at 147 nm. A second method utilizes a direct ...
In this paper, a novel type of a corona discharge plasma reactor was designed, which consists of needle-plate-combined electrodes, in which a series of needle electrodes are placed in a glass container filled with flue gas, and a plate electrode is immersed in the water. Based on this model, the removal of NO and SO2 was tested experimentally. In addition, the effect of streamer polarity on the reduction of SO2 and NO was investigated in detail. The experimental results show that the corona wind formed between the high-voltage needle electrode and the water by corona discharge enhances the cleaning efficiency of the flue gas because of the presence of water, and the cleaning efficiency will increase with the increase of applied dc voltage within a definite range. The removal efficiency of SO2 up to 98%, and about 85% of NOx removal under suitable conditions is obtained in our experiments.
Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).
Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).
A high-voltage cathode initiates an electron emission, resulting in a reduction in the carbon dioxide concentration in exhaust gas from the burning of hydrocarbon fuel. Assuming that the observed carbon dioxide reduction is originated from the molecular decomposition, the energy needed for the endothermic reaction of this carbon dioxide reduction may stem primarily from the internal energy reduction in the exhaust gas in accordance of the first law of the thermodynamics. An oxygen increase due to the reduction in carbon dioxide in a dischargegas was observed in real time.
Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...
Externally Fired Combined Cycles (EFCCs) can increase the amount of electricity produced from ash bearing fuels up to 40%, with overall powerplant efficiencies in excess of 45%. Achieving such high efficiencies requires high temperature-high pressure air heaters capable of driving modern gas turbines from gas streams containing the products of coal combustion. A pilot plant has been constructed in Kennebunk, Maine to provide proof of concept and evaluation of system components. Tests using pulverized Western Pennsylvania bituminous coal have been carried out since April, 1995. The ceramic air heater extracts energy from the products of coal combustion to power a gas turbine. This air heater has operated at gas inlet temperatures over 1,095 C and pressures over 7.0 atm without damage to the ceramic tube string components. Stable gas turbine operation has been ...
Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiences, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.
Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiencies, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, nongray gas-particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference method with an iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band ...
The interaction of thermal radiation with conduction and convection in thermally developing absorbing, emitting, non-gray gas particulate turbulent suspension flow through a circular tube is investigated. The contribution of thermal radiation is obtained through evaluation of the total hemispherical emittance of the particulate cloud and through evaluation of single band absorptances for molecular gases, modified to account for the interaction with the particles. The governing differential equation is derived as a (nonlinear) energy equation, coupled with integral equations to find the thermal radiation contributions. The energy equation is solved numerically by an implicit finite difference with its iterative procedure. Qualitative results for Nusselt numbers are shown for a variety and range of parameters, such as optical thickness of particulates and single molecular gas bands, relative gas band ...
Cesium recovery from the polluted layers in the 1/3 scale hydrogen negative ion source for LHD-NBI system has tested. It was found, that the cesium recovery can be produced by additional discharges as from the cesium layer, aged by tungsten and residual gas, so as from the cesium layers, polluted by an occasional water leak. The highest cesium recovery to NI production was produced by a xenon arc, while glow discharge and arcing in hydrogen were less effective. The mechanism of recovery is the ejection of cesium from the underlying enriched layer by the arc and its transport to the surface. (author)
A high-density gas jet supersonic nozzle is reported in this paper. The jitter and actuation time of the nozzle is determined by the pin discharge and laser spark radiation respectively. The jitter time of the nozzle is within 10 ?s with the backing pressure as high as 25 bar. With a nanosecond laser pulse focused on the gas jet about 1 mm below the nozzle, the actuation time is calculated to be about 15 ms by detecting the laser produced spark radiation, which reveals the existence of the gas jet and the relative gas density evolving with time. Consequently the gas density is estimated to be well above 1019 cm-3, compared with theoretical simulations from the nozzle parameters.
The production of ozone in a negative corona discharge fed by carbon dioxide with embedded traces of oxygen and water has been studied. The presence of traces of oxygen in both pure and dry CO_2 leads to an increase in nascent ozone concentrations. In contrast, traces of water vapour (0-800 ppm) are shown to rapidly suppress ozone concentrations with the largest decreases being observed at lowest gas pressures in the discharge (300 Torr). The presence of water vapour did not considerably affect the electrical properties of negative dc corona suggesting that a chemical process is responsible for the ozone loss. We have shown that the addition of water up to a concentration of 1500 ppm has only a marginal effect on the processes of ozone formation but the catalytic cycle of ozone destruction involving OH radicals can be the reason for observed decrease in the total ozone concentration with increasing water concentration.
Results of experiments performed utilizing high-power microwave sources for laser-discharge switching and preionization are reported. These results are not definitive, but are promising. Significant preionization using microwaves is possible. Some ability to switch the discharge and operate a laser have been demonstrated. More work needs to be performed to perfect the microwave coupling to the laser mixture. In particular, experiments with the microwaves better concentrated between the electrodes should be performed. The best way to accomplish this appears to be using the side-feed geometry; however, a large expansion of the microwaves should occur (to well below the power able to break down the window), and then a cylindrical lens should be used to focus the microwaves between the electrodes. 2 references.
The decomposition of three ?-lactam antibiotics (amoxicillin, oxacillin and ampicillin) in aqueous solution was investigated using a dielectric barrier discharge (DBD) in coaxial configuration. Solutions of concentration 100 mg/L were made to flow as a film over the surface of the inner electrode of the plasma reactor, so the discharge was generated at the gas-liquid interface. The electrical discharge was operated in pulsed regime, at room temperature and atmospheric pressure, in oxygen. Amoxicillin was degraded after 10 min plasma treatment, while the other two antibiotics required about 30 min for decomposition. The evolution of the degradation process was continuously followed using liquid chromatography-mass spectrometry (LC-MS), total organic carbon (TOC) and chemical oxygen demand (COD) analyses. PMID:21514950
Purge water from a typical wet flue gas desulfurization system contains myriad chemical constituents and heavy metals whose mixture is determined by the fuel source and combustion products as well as the stack gas treatment process. A well-designed water treatment system can tolerate upstream fuel and sorbent arranged in just the right order to produce wastewater acceptable for discharge. This article presents state-of-the-art technologies for treating the waste water that is generated by wet FGD systems. 11 figs., 3 tabs.
Na/S battery can have the higher energy density and higher power density than that of existing high performance secondary battery. This battery is expected to use for electric load leveling and electric vehicle. Ni/MH battery was developed in advanced countries, but it is one of the advanced technologies which are preserved in their own country. In the study on Na/S battery, properties of B{sup -}alumina electrolyte was investigated. Also the construction technologies of this test cell was established by combining tube type of B{sup -}alumina solid electrolyte with Na-, S- electrode etc. Especially of this cell, charge/discharge performance and open circuit voltage was examined. Mi/MH battery sample were tested with SBT500 system for self-discharge rate at room temp, was measured. It was found that the electrolyte and separator can be optimized to minimize the self-discharge rate. (author). refs., ...
Throughout the last decades, plasma technology has been established in a series of surface treatment applications, e.g. for semiconductor processing or optical coatings. The majority of plasma assisted technologies is based on low pressure processes. In recent years, however, non-thermal atmospheric pressure discharges have attracted considerable interest because of their simplified technical devices for industrial applications as compared to low pressure processes which require vacuum equipment. Hence, batch processing can be avoided, thus facilitating the implementation of plasma process steps into production lines. Investment costs are cut down significantly. The use of atmospheric pressure plasmas for technical applications dates back to the ozone production with dielectric barrier discharges (DBD) by Siemens in 1857. Lately, the application of atmospheric pressure plasmas for surface treatment has been reported, e.g. for the treatment of ...
The preparation and performance of membranes for application to hydrogen separation from coal-derived gas is described. The membrane material investigated was dense amorphous silica deposited on a suitable support by chemical vapor deposition (CVD). Two types of support materials were pursued. One type consisted of a two-layer composite, zeolite silicalite/{alpha}-Al{sub 2}O{sub 3}, in the form of tubes approximately 0.7 cm in diameter. The other type was porous glass tubes of diameter below 0.2 cm. The first type of support was prepared starting from {alpha}-Al{sub 2}O{sub 3} tubes of 1{micro}m mean pore diameter and growing by hydrothermal reaction a zeolite silicalite layer inside the pores of the alumina at the OD side. After calcination to remove the organic template used in the hydrothermal reaction, CVD was carried out to deposit the final silica layer. CVD was carried out by alternating exposure ...
The report describes tests to demonstrate the feasibility of using a vertical-tube, falling-film, vapor-compression evaporator to concentrate waste water from a flue gas desulfurization (FGD) process. Tests showed that waste water from the Chiyoda FGD process can be concentrated ...
Using an experimental pilot plant, designed and built for the tests, the influence of the following parameters was determined: desulphurization of the test gas, temperature, residence time in the reactor tube, concentration of the hydrogen sulphide and desulphurization agent, size of the particles which comprise the agent and composition of the gas. Allowance was made for the effect of calcination and carbonisation. Desulphurization was carried out with limestone on a gaseous mixture of CO and H/sub 2/. A mathematical description of the test findings and yield is presented. 8 refs.
Accurate prediction of tube surface temperature is important for determining whether accelerated superheater corrosion will occur in kraft recovery boilers. A heat transfer model, which combines an iterative numerical solution scheme with a more realistic flue gas flow field obtained from the CFD code FLUENT, has been developed to predict the tube, steam and flue gas temperatures in the superheater region. Results of tests performed for a recovery boiler show that temperatures predicted using the model are in good agreement with actual temperatures measured using thermocouples. The presence of a large flue gas recirculation zone above the bullnose is shown to have an adverse effect on the heat transfer in the superheater region. 9 refs., 12 figs., 1 tab.
A novel system has been deployed to obtain geochemical samples of water and gas, at in situ pressure, during a geologic CO2 sequestration experiment conducted in the Frio brine aquifer in Liberty County, Texas. Project goals required high-frequency recovery of representative and uncontaminated aliquots of a rapidly changing two-phase (supercritical CO2-brine) fluid from 1.5 km depth. The datasets collected, using both the liquid and gas portions of the downhole samples, provide insights into the coupled hydro-geochemical issues affecting CO2 sequestration in brine-filled formations. While the basic premise underlying the U-Tube sampler is not new, the system is unique because careful consideration was given to the processing of the recovered two-phase fluids. In particular, strain gauges mounted beneath the high-pressure surface sample cylinders measured the ratio of recovered brine to supercritical CO2. A quadrupole mass ...
Flame lengths inside circular tubes, using an (in-shot) atmospheric burner design commonly found in gas-fired residential furnaces were visually observed for natural gas and air under various operating conditions. The flame length data were reduced into dimensionless flame lengths, which were shown to be linearly proportional to the Peclet number of the fuel and air mixture. The dimensionless flame length dependence reported does not scale according to the classical flame models: pre-mixed (laminar) flame or diffusion flame. Instead, the flame length dependence was found to scale with the fuel burn speed, gas/mixture properties (evaluated at the adiabatic flame temperature), and flow parameters. Currently, this is the only flame length study available for the standard atmospheric burner designs commonly used in residential heating products. The results and data reduction provide an easy method to ...
The present paper deals with the conversion of solar energy in a gas turbine plant with a parabolic dish collector. Particular consideration is devoted to the thermodynamic and mechanical design and partload behavior of the receiver. The incident sunlight is focussed by the parabolic dish and then beamed into the cavity receiver. Here the working medium of the gas turbine flows through tubes and is heated up to the receiver outlet temperature. The task of the receiver is to transfer the radiated energy as efficiently as possible to the working medium. Furthermore the required heating surface should be small as possible i.e. optimum use must be made of the tube material with respect to its state of stress. It is shown which geometric and thermodynamic plant parameters influence these two design criteria. An optimum receiver design is presented on the basis of the results thus obtained. Finally, the ...
The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data ...
Production of ozone and OH radical is required to advance the plasma chemical reactions in the NOx removal processes for combustion gas treatment. The corona discharge to the water surface is expected to induce the good conditions for the proceeding of the NO oxidation and the NO_2 dissolution removal into water. In order to get the fundamental data of the corona discharge over the water surface, the positive and negative V-I characteristics and the ozone production were measured with the multi needle and the saw-edge type of the discharge electrodes. The pulse corona characteristics were also measured with some different waveforms of the applied pulse voltage. The experiments were carried out under the atmospheric pressure and room temperature. Both the DC and the pulse corona to the water surface showed a stable and almost the same V-I characteristics as to plate electrodes though the surface of water ...
Field corrosion tests were conducted on eight single tube materials and two welded overlay materials in three typical Japanese waste incineration plants in an effort to develop new corrosion-resistant superheater tubes capable of functioning efficiently under temperature and pressure conditions of 500 C and 100 kgf/cm{sup 2}-g in high-efficiency waste-to-energy (WTE) plants. Austenitic alloys containing higher concentrations of chromium, nickel, and molybdenum [Cr + Ni + Mo] showed excellent corrosion-resistant properties, and the new alloys JHN24 and HR30M showed good corrosion resistance. Different corrosion rates found in each of the three plants were explained by differences in operating conditions, such as gas temperature, concentration of molten salts resulting from chlorine (Cl) content of deposits, heavy metal (zinc oxide [ZnO] + lead oxide [PbO]) content, etc. It was confirmed that the corrosion rate of materials ...
Here I provide a brief overview of recent experimental gas-phase measurements using the Selected-Ion Flow Tube or SIFT technique at 294#+-#2 K with helium buffer gas at 0.35 Torr for reactions which remove electrons from the C_6_0 molecule or donate electrons to singly and multiply-charged C_6_0 cations. The results of these measurements have provided new insight into physicochemical aspects of electron transfer and have revealed the occurrence of unprecedented electron transfer reactions at thermal energies. (author).
A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.
A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.
Existing applications of Alloy 800 are summarized, with particular reference to its use in various types of reactor. The need for a co-ordinated research and development programme is stressed, and the variables to be explored are outlined. The papers relating to the problem of corrosion and cracking in water and steam are considered. the strength and ductility of Alloy 800 is considered. Finally, sections of the summary deal with the use of Alloy 800 for (a) sodium cooled fast reactor boiler tubes; (b) the high temperature gas cooled reactor; and (c) PWR steam generator tubes. (U.K.).
The PERMCAT is a membrane reactor proposed for processing fusion reactor plasma exhaust gas: tritium removal is obtained by isotopic swamping operating in counter-current mode. In this work, a membrane reactor using a permeator tube of length about 500 mm produced via diffusion welding of Pd-Ag thin foils is described. An appropriate mechanical design of the membrane module has been developed in order to avoid any significant compressive and bending stresses on the very long and thin wall permeator tube: two expanded bellows have been applied to the Pd-Ag tube, so that it has been pre-tensioned before operating. The elongation of the metal permeator under hydrogenation has been theoretically estimated and experimentally verified for properly designing the membrane reactor.
Exposure of teachers of physics to X-radiation emitted by instruments which are used for demonstrating rarefied gasdischarges during physics lessons at secondary schools is discussed. The measurements performed provide an explicit evidence that an effective, annual exposure dose under the most unfavorable conditions does not exceed admissible levels according to Polish regulations pertaining to persons non-occupationally exposed to ionizing radiation. (author). 3 refs,1 fig.
On handling nitric solutions in the glove box nitrous gases are formed that are sucked off via a heated activated charcoal filter and a catalyst cartridge containing e.g. the FG 590 H catalist (Degussa). By the activated charcoal the nitrous gases are reduced to N/sub 2/ and CO gas; the catalyst will oxidize CO to CO/sub 2/. The CO/sub 2/ obtained is discharged through an exhaust air filter in the glove box.
The possibility of surface modification of high-speed steel cutting tool by means of vacuum-plasma treatment including ion nitriding in gas plasma followed by the deposition of wear resistant (Ti, Al)N coatings in metal-gas plasma of a vacuum arc discharge is studied. The regularities of nitrided layer formation and the structure of these layers under various operation conditions of cutting tool are investigated. Optimum conditions of vacuum-plasma treatment providing the best wear resistance of cutting are determined
Non-thermal plasma treatment is a promising technique for the destruction of volatile organic compounds in waste gas. A relatively unexplored technique is the atmospheric negative dc multi-pin-to-plate glow discharge. This paper reports experimental results of allyl alcohol degradation and ozone production in this type of plasma. A new model was developed to describe these processes quantitatively. The model contains a detailed chemical degradation scheme, and describes the physics of the plasma by assuming that the fraction of electrons that takes part in chemical reactions is an exponential function of the reduced field. The model captured the experimental kinetic data to less than 2 ppm standard deviation.
Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall`s resistivity requirement ({sigma}*t = 2E5 {Omega}{sup {minus}1}). For a 4.2 K beam tube the Cu thickness is 100 {mu}m (RRR=30,6.7 T, {sigma}=2E9{Omega}{sup {minus}1}m{sup {minus}1}). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam ...
Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall's resistivity requirement ([sigma]*t = 2E5 [Omega][sup [minus]1]). For a 4.2 K beam tube the Cu thickness is 100 [mu]m (RRR=30,6.7 T, [sigma]=2E9[Omega][sup [minus]1]m[sup [minus]1]). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A ...
An embodiment of a mercury-free fluorescent lamp combines a low pressure rare gasdischarges with a phosphor having a quantum efficiency grater than one. The choice of the rare gas depends on a number of factors, one of which is the resonance transition energy. Less demand is placed the quantum efficiency of the phosphor for a lower energy resonance photon. Xenon has the lowest energy resonance transition of the stable rare gases at 8.5 eV (147 nm) and thus is a good candidate to study. The usefulness of a xenon-based discharge depends on the radiant emittance of the discharge at the resonance wavelength of 147 nm. The radiant emittance from a low pressure xenon positive column discharge is measured using two independent techniques. The first relies on the measurement of the resonance level density using absorption techniques. The effective decay rate of the ...
Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digital image format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).
Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a ...
Paraquat is a nonselective contact herbicide of great toxicological importance, being associated with high mortality rates, mainly due to respiratory failure. We report the case of a 22-year-old male admitted to the emergency room with a sore throat, dysphagia, hemoptysis, and retrosternal pain after the ingestion of 50 mL of a paraquat solution, four days prior to admission. Chest CT scans revealed pulmonary opacities, pneumomediastinum, pneumothorax, and subcutaneous emphysema. The patient was submitted to two cycles of immunosuppressive therapy with cyclophosphamide, methylprednisolone, and dexamethasone. The pulmonary gas exchange parameters gradually improved, and the patient was discharged four weeks later. The clinical and tomographic follow-up evaluations performed at four months after discharge showed that there had been further clinical improvement. We also present a brief review of the literature, as well as a ...
We have studied the nature of continuum emitted in the visible spectral range from a noncontracted positive column of discharge in a cesium vapor-xenon mixture at a pressure of 45 Torr and at a degree of ionization below 3 ? 10?6. The main contribution to the continuous emission under such conditions is due to electron-xenon atom bremsstrahlung. The intensity of emission has been experimentally and theoretically studied as a function of the electric field strength and electron density in the positive column. It is established that an increase in the visible emission intensity with the electric field strength is related to an increase in the number of hot electrons in plasma.
Experiments of plasma nitriding of titanium are carried out by two plasma sources. One is a microwave discharge plasma source under several Torr, and the other is a nitrogen arc jet generated under atmospheric pressure followed by rapid expansion into a gas wind tunnel. The relationship between the surface density of nitrogen atoms in the #alpha#-Ti and various plasma parameters is systematically studied. For the microwave nitrogen plasma, it is found that the effect of the vibration temperature is the most essential for the surface nitriding, whereas the effect of electron temperature, density and rotation temperature is less remarkable. It is also found that the higher vibration temperature of the microwave discharge nitrogen plasma makes the target temperature higher, and consequently, the surface density of atomic nitrogen remarkably increased. However, the effect of target temperature is less remarkable for the arc jet ...
An apparatus capable of producing current or voltage controlled positive and negative ion beams in 1-atm oxidizing and nonoxidizing ambients between 25/sup 0/ and 950 /sup 0/C is presented. The apparatus utilizes a point-to-plane corona discharge in the gas phase. Room-temperature experiments revealed that the small differences in ion beam shape between the two polarities is primarily due to the difference in applied voltage required to produce the same current for the two polarities. Due to increased ion mobility and decreased threshold voltage at higher temperatures, a slight broadening of the ion beam current-density profiles for both positive and negative ions is predicted.
The permeation of hydrogen through steam generator tubes at high temperatures ({approx} 300 degrees C) has been studied using an electrochemical technique. With this technique, hydrogen is generated on one side of the tube and monitored on the other side. The time for the hydrogen to reach the other side is used to determine the diffusion coefficient of hydrogen in the tube. Boundary conditions at the entry and exit sides have been investigated separately. Preliminary studies were performed on Stainless Steel 316 and Nickel Alloy 800 to better understand the influence of the solution chemistry on the electrochemical evolution of hydrogen. The surface phenomena effect and the trapping effect are discussed to account for differences observed in the permeation response. The hydrogen permeation through oxides at the exit side has been studied. Two nickel alloys (Alloy 800 and Alloy 600), materials widely used for steam ...
The authors investigated the application of pulsed corona discharge process to the removal of SO{sub 2} and NO{sub x} from industrial flue gas of an ioron-ore sintering plant. This study was performed on a pilot scale, which is the most advanced demonstration of this process. The flow rate of 5000 m{sup 3}/h of the flue gas was successfully treated. The electrode structure of the corona reactor is the same with that of conventional electrostatic precipitator. The authors made use of magnetic pulse compression technology to produce repetitive high voltage pulse. Pulse width (full width at half maximum) was reduced to less than 1 {micro}s by connecting a resister in parallel with the corona reactor. An inductor was added to the resister in series to minimize the loss by restricting the current flowing through the resister. By this way, they were able to deliver pulse power with peak voltage of 110 kV and peak current of 2.3 ...
A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were investigated in detail. Furthermore, the design conception and basic ...
A series of experimental measurements of ozone concentration produced by irradiation of noble gas (He, Ne, and Ar)-O_2 and noble gas-O_2- SF_6 mixtures with energetic (MeV) helium and lithium ions are reported. Continuous irradiations at dose rates of 10"1"5-10"1"7 eV cm"-"3 S"-"1 for a few hundred milliseconds were used. The resulting ozone concentration was found to be nonlinear with dose rate for a given irradiation time. This nonlinearity was effectively reduced by an increase in noble gas pressure. Few mole percent addition of SF_6 generally resulted in an increase in the ozone concentration. This increase was highest for lower noble gas pressures and longer irradiation times. Further SF_6 addition, however, caused a reduction in the ozone concentration. Results are explained by considering the relevant reactions responsible for ozone production and loss.
The design and parameters of a UV-VUV spontaneous radiation source - an excilamp operating on chlorides of rare gases ArCl{sup *}, KrCl{sup *} and XeCl{sup *} in the wavelength range 175-308 nm are presented. The Ne-Xe(Kr, Ar)-HCl mixtures were excited by a high-pressure self-sustained discharge with spark preionisation. It is shown that upon pumping mixtures of rare gases and halogens by a transverse discharge, the intensities of the B-X emission band of molecules ArCl{sup *}, KrCl{sup *} and XeCl{sup *} are comparable and up to 90% of the emission energy of excilamps can be concentrated in the UV region. The peak UV power density at 222 and 308 nm on the output window of the excilamp was {approx}2 kW cm{sup -2} for the pulse energy up to {approx} 3 mJ. The output emission energy of the excilamp at 175 nm achieved {approx}0.6 mJ and the peak power density was {approx}0.4 kW cm{sup -2}. (laser applications and other topics in quantum ...
Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the ...
Traditional two-phase flow-regime criteria based on the gas and liquid superficial velocities may not be suitable to the analyses of rapid transient or entrance flows by the two-fluid model. Under these conditions, it is postulated that direct geometrical parameters such as the void fraction are conceptually simpler and therefore more reliable parameters to be used in flow-regime criteria than the traditional parameters. From this point of view, new flow-regime criteria for upward gas-liquid flow in vertical tubes have been developed considering the mechanisms of flow-regime transitions. These new criteria can be compared to existing criteria and experimental data under steady-state and fully developed flow conditions by using relative velocity correlations. The criteria showed reasonable agreements with the existing data for atmospheric air-water flows. Further comparisons with data for steam-water in round ...
Traditional two-phase flow-regime criteria based on the gas and liquid superficial velocities may not be suitable to the analyses of rapid transient or entrance flows by the two-fluid model. Under these conditions, it is postulated that direct geometrical parameters such as the void fraction are conceptually simpler and therefore more reliable parameters to be used in flow-regime criteria than the traditional parameters. From this point of view, new flow-regime criteria for upward gas-liquid flow in vertical tubes have been developed considering the mechanisms of flow-regime transitions. These new criteria can be compared to existing criteria and experimental data under steady-state and fully developed flow conditions by using relative velocity correlations. The criteria showed reasonable agreements with the existing data for atmospheric air-water flows. Further comparisons with data for steam-water in round ...
Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.
This heat exchanger is a critical step in the development of the Externally Fired Combined Cycle power system, a direct-coal combustion power plant (gas turbine). SiC is the only material with the needed resistance to creep, thermal shock, and oxidation; however a protective coating is needed. Ten candidate materials were identified: alumina-based materials, materials stable with SiO, and low expansion materials. An initial screening study should be performed.
Based on the results obtained for C-N and Si-C-N films, a systematic investigation of reactive magnetron sputtering of hard quaternary Si-B-C-N materials has been carried out. The Si-B-C-N films were deposited on p-type Si(100) substrates by dc magnetron co-sputtering using a single C-Si-B target (at a fixed 20% boron fraction in the target erosion area) in nitrogen-argon gas mixtures. Elemental compositions of the films, their surface bonding structure and mechanical properties, together with their oxidation resistance in air, were controlled by the Si fraction (5-75%) in the magnetron target erosion area, the Ar fraction (0-75%) in the gas mixture, the rf induced negative substrate bias voltage (from a floating potential to -500 V) and the substrate temperature (180-350 deg. C). The total pressure and the discharge current on the magnetron target were held constant at 0.5 Pa and 1 A, respectively. The energy and flux of ...
In order to develop new corrosion resistant superheater tubes capable of functioning efficiency under temperature and pressure conditions of 500 C and 100 ata used in high efficient waste-to-energy (WTE) plants, field corrosion tests were conducted on eight single tube materials and two welded overlay materials at metal temperatures of 450 C and 550 C for 700 and 3,000 hours, respectively, in three typical japanese waste incineration plants. The test results indicate that austenitic alloys containing higher concentrations of [Cr + Ni + Mo] show excellent corrosion resistant properties and new alloys of JHN24 and HR30M have good corrosion resistance. The different corrosion rate found for each of the three plants could be explained by differences in the severity of corrosion factors, such as, gas temperature, concentration of molten salts due to Cl content of deposits, and heavy metal [ZnO + PbO] content etc. It was also ...
Fully-fired combined cycle plants utilizing the high temperature gas turbine discharge as gas intake for a coal-fired steam generator were developed in the 1960's. Long-term experience and the excellent reliability statistics of the gas turbines of these plants have proven that the thermodynamic, economical and ecological advantages of combined cycle units over conventional units strongly suggest such plants for fossil-fuel applications. This paper describes the design and operation of these plants. Topics are Gersteinwerk Unit K combined-cycle power plant, plant design concept, design criteria and performance, gas turbines, steam generators, steam turbines, various modes of operation, typical plant start-up, environmental considerations, prototype plants and topping old steam turbine plants. It concludes that combined-cycle plants provide efficiencies over 45% with low ...
An approximate analyzing model was developed to predict the azimuth of zigzag streamline, the distribution ratio between two neighboring layers and the radial distribution among the layers of the gas passing through the shaft of blast furnace loaded in layers. The theoretical basis of the approximate analysis is composed of the material balance derived from the assumption that any stream line surrounded with two streamlines is isolated and no material transfer occurs through the tube wall, and of the energy theory that the stream tube and passage are formed so that the total pressure drop in the whole system is the minimum. The effects of the apparent angle of repose between two layers, the packing volume and the passage resistance on the non-uniform flow in the layer were evaluated on the basis of the model. The result calculated by the approximate analysis agrees with the result by the numerical analysis based on the ...
A simple analytical model of the barrier discharge in a long gap between opposing plane electrodes is developed. It is shown that the plasma density becomes uniform over large part of the gap in the course of the discharge development, so that one can speak of a formation of a dynamic positive column. The column completely controls the dynamics of the barrier discharge and determines such characteristics as the discharge current, discharge duration, light output, etc. Using the proposed model, all discharge parameters can be easily evaluated
We present a large set of merger simulations of early-type disc galaxies with mass ratios of 1:1 and 3:1 and 10% of the total disc mass in gas. In contrast to the collisionless case equal-mass mergers with gas do not result in very boxy remnants which is caused by the suppression of box orbits and the change of the projected shape of minor-axis tube orbits in the more axisymmetric remnants. The isophotal shape of 3:1 remnants and the global kinematic properties of 1:1 and 3:1 remnants are only weakly affected by the presence of gas. 1:1 remnants are slowly rotating whereas 3:1 remnants are fast rotating and discy. The shape of the stellar LOSVD is strongly influenced by gas. The LOSVDs of collisionless remnants have broad leading wings while their gaseous counterparts show steep leading wings, more consistent with observations of elliptical galaxies. We show that this change is also ...
With the aim of optimizing the nitriding process parameters (temperature and gas mixture ) experimental studies of the plasma nitriding of Ck 15 steel were carried out, using a D. C. glow discharge. Nitriding treatments were performed at 450, 500 and 550 and N_2/H_2 volume ratio of 3/1, 1/1 and 1/3 for 5 hours. Nitriding treatment produces modified surface layer consisting of an outer compound layer and an inner diffusion layer.The plasma nitriding of Ck 15 produce single white layer consisting of #gamma#-(Fe_4N).
Experimentally it is shown that a movable grounded metallic plate placed inside a multi-dipole magnetic cage can vary the diffused plasma parameters such as density, plasma potential and electron temperature. Plasma is solely produced in the source section of a double plasma device by a dc hot filament discharge and a low-density plasma is produced in the target section by local ionization of neutral gas by the high energetic electrons coming from the source section. A grounded movable stainless steel plate is inserted in the target section of the device. The floating potential of the plate also changes depending on the position of the plate inside the magnetic cage.
The deuterium uptake behavior of Zr-2.5Nb pressure tubes in Wolsung Unit 1 was analyzed in terms of longitudinal location, operation time, and coolant temperature. The results were compared with those obtained from Canadian CANDU reactors. The amount of deuterium uptake was higher at the outlet part than at the inlet part and was also higher when subjected to a longer operation time and a higher coolant temperature. The hydrogen uptake of Zr-2.5Nb in a hydrogen gas atmosphere was dependent on the microstructure of the alloy. The aged Zr-2.5Nb consisting of {alpha}-Zr and {beta}-Zr phases. The hydrogen in the alloy decreased the rate of oxidation. This could be explained in terms of the cathodic controlled reaction of Zr-2.5Nb oxidation. (author)
Field studies were conducted May 28-June 1, 1979, to determine the chemical composition and physical behavior of discharges from an offshore gas drilling rig in the central basin of Lake Erie. The drilling operation was observed for four days, from rig jackup to the circulation of mud through the borehole after drilling had been completed. Resuspension studies using nephelometry, supplemented with chemical analyses, indicated little resuspension of lake bottom materials or release of metals to the water column during rig jack-up. Portions of the turbidity plumes generated during drilling were buoyant. Three surface turbidity plumes were mapped with nephelometry to a point at which particulate concentrations reached background levels in the Lake. Detectable plumes were approx. 400 to 1500 m in length and had maximum widths < 230 m. A chemical survey conducted in the plume during early gas shows indicated that ...
The analysis is submitted in support of the effluent limitations guidelines and standards for the Coastal Oil and Gas Industry. The report analyzes the cost-effectiveness of 10 regulatory options organized by three wastestreams. The document compares the total annualized cost incurred for each of the regulatory options within each wastestream to the corresponding effectiveness of that option in reducing the discharge of pollutants. Section Two discusses the cost-effectiveness methodology used and identifies the pollutants included in the analysis, presenting their toxic weighting factors and removal efficiencies. Section Three presents the results of the analysis. In Section Four, the cost-effectiveness values are compared to cost-effectiveness values for other promulgated rules. Appendix A presents data on pollutants, pollutant removals, annualized costs, and other, more detailed information.
Recently the increase of steam temperature and pressure of power plant is required to enhance the thermal efficiency and reduce the CO{sub 2} emission. For the application to advanced USC (Ultra Super Critical) boiler with steam temperature around 700 C, the application of Ni-based alloy such as Alloy617 will be necessary. A new Ni-based alloy USC141 (20Cr-10Mo-2Ti-Al-bal.Ni) with excellent creep rupture strength and low thermal expansion has been developed by Hitachi Ltd. and Hitachi Metals Ltd. as the candidate material for 700 C USC turbine components. In present work, to investigate the possibility for boiler tube application of USC141, its weldability and high temperature strength properties were experimentally examined. The tested material as solution-treated condition shows higher creep rupture strength than that of Alloy617. GTAW (Gas Tungsten Arc Welding) trials of tubular specimen using NIMONIC263 filler wire were conducted ...
The authors investigate the optimisation of solar-heated cavity receivers in which solar energy collected by a paraboloid collector is converted into electrical energy. The focussed solar energy enters the receiver through an aperture to heat the working fluid, which flows inside the receiver tubes and is compressed by the compressor of a gas turbine system, to the highest process temperature. A method of calculating the distribution on the inner receiver surfaces of the solar radiation reflected by the paraboloid collector is presented to begin with. The interchange of radiant energy inside the receiver cavity can be calculated on this basis, including the radiation loads, the temperatures of the inner receiver walls, and the radiative and convective losses. The temperature fields in the tube walls must be known for determining the strength required of receiver tubes; they can be derived from the ...
The development of a silicon carbide (SiC) heat exchanger is a critical step in the development of the Externally-Fired Combined Cycle (EFCC) power system. SiC is the only material that provides the necessary combination of resistance to creep, thermal shock, and oxidation. While the SiC structure materials provide the thermomechanical and thermophysical properties needed for an efficient system, the mechanical properties of the SiC tubes are severely degraded through corrosion by the coal combustion products. To obtain the necessary service life of thousands of hours at temperature, a protective coating is needed that is stable with both the SiC tube and the coal combustion products, resists erosion from the particle laden gas stream, is thermal shock resistant, adheres to SiC during repeated thermal shocks (start-up, process upsets, shut-down), and allows the EFCC system to be cost competitive. This demanding set of ...
The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in the heat transfer ...
The Economic Analysis (EA) report is written to address the impacts of this proposed Effluent Limitation Guidelines and Standards for Synthetic-Based and Other Non-Aqueous Drilling Fluids. Currently, effluent guidelines pertaining to the discharge of drilling fluids address two specific types of fluids: Oil-based drilling fluids (OBFs) that use diesel and mineral oil, which are prohibited from being discharged; and Water-based drilling Fluids (WBFs), which can be discharged subject to meeting certain discharge requirements, including a sheen test and an aqueous toxicity test, in certain limited offshore regions. Section Two presents sources of data, Section Three presents the industry profile, Section Four discusses the regulatory costs of options under consideration for the proposed rulemaking, and Section Five discusses the impacts of the proposed rule on firms, well drilling, and production, and also ...
Extensive research into the treatment and control of Volatile Organic Compounds (VOCs) from semiconductor industry manufacturing processes has identified the need for alternatives to existing combustion devices. Specifically, semiconductor manufacturing design is moving toward exploiting effective, small-scale, abatement control technologies for specific point-of-use (POU) waste streams associated with a particular component or manufacturing tool. The Silent Discharge Plasma (SDP) developed at Los Alamos National Laboratory is a nonthermal plasma technology created by a dielectric-ballasted electrical discharge. Influent gas-phase pollutants are destroyed in the reactor by the free radicals or electrons generated by the plasma. This paper examines the potential for SDP to be used in niche circumstances for POU control of VOC exhaust streams specific to the semiconductor industry. A sensitivity analysis is presented, showing ...
The two-phase annular regime is characterized by a high velocity gas stream flowing through the core of the tube surrounded by a thin, highly agitated liquid film flowing concurrently along the tube wall. Part of the liquid may be entrained as droplets in the gas phase. The specific goals of this study were to measure fully developed rates of interchange and entrained fraction over a wide range of flow variables in the upward configuration of the annular regime, to obtain a more fundamental understanding of liquid interchange phenomena via studies of liquid film characteristics and to develop an improved design correlation for the entrained fraction. Towards this end, air-water experiments were conducted in two vertical pipe lines, 2.54 and 4.20 cm in diameter. Air velocities ranging from 20 to 120 m/s and total liquid flow rates ranging from 10 to 100 g/s were investigated. Two models for the rate of ...
We present a high temperature heat oven with merits of conventional heat pipe oven and study ots thermal characteristics. The oven consists of stainless steel body and heating part of three layers of ceramic tubes. We obtained the maximum temperature of about 1350. deg. C at the center which was measured by thermocouple and infrared thermometer. And we compared the heating characteristics in the cases of external heating and no extent heating. It was applied to self diffraction experiment in the samarium gas which was one of the high melting point material.
In most industrial processes operating at elevated temperatures, protective oxide layers perform a vital duty in protecting the underlying metallic alloys from process gases. Coal-fired combined cycle power generation systems present a number of process conditions in which the properties of the protective oxide layers are particularly important. This paper discusses two of these particular conditions: (1) `erosion/corrosion` of in-bed heat exchanger tubing and (2) thermal cycling of hot gas path components. For both these situations, the desirable properties of protective scales are outlined. The behaviour of scales in practice are highlighted. 33 refs., 6 figs., 2 tabs.
The relationship between the current density distribution and the electron density profile during the flat-top phase of Ohmic discharges in TEXTOR has been investigated by means of far-infrared interferometry and polarimetry. It is found that neither gradual nor rapid changes of the electron density distribution (induced by continuous gas feed or pellet injection) alter the current profile significantly. The conclusion is drawn from the temporal evolution of the measured Faraday rotation signals #alpha#_e_x_p(x,t) which are proportional to the line integrals of n_c times the poloidal magnetic field component B_p_c along the probing beam paths (x is the distance of a chord from the plasma centre). By taking into account the known variation of the density profile but keeping the current distribution fixed, theoretical signals #alpha#_s_i_m(x,t) can be calculated which match the observed waveforms very well without any need to readjust the ...
Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).
A continuous gas laser may be operated reliably with an increased pressure level and current level without significant cathode sputtering. This increases the service life and the specific power of the laser. The design eliminates the formation of arcs in operational conditions, which also has a positive influence on laser operation. The proposed laser is used successfully in modern interferometry, in geodesy and in materials analysis. The laser design is characterized by the presence of separation rings inside the coaxial cathode. The separation rings are fastened to the anode. The anode is a perforated tube that is connected to two final protective rings. Electrodes from the housing pass through the final rings. In order to increase laser power, two or more lasers of such design are used and are positioned on the same axis in a single housing.
Lappeenranta University of Technology (LTKK) and VTT Energy carried out a series of preliminary tests in 1999 to study the behavior of noncondensable (NC) gases in VVER geometry. The tests aimed at studying the effect of NC gases on system thermal-hydraulics and on heat transfer in a horizontal steam generator (HSG). The system behavior can be affected by hydrogen produced in the core in case of a severe accident, by nitrogen from hydro-accumulators released into the primary circuit in case of a loss-of-coolant accident (LOCA) and more generally by any NC gas in all cases where cooling is ensured by natural circulation. A secondary objective of the tests - the first series of tests ever performed with NC gas with PACTEL - was to find out, if the instrumentation of PACTEL was adequate for this type of tests and if it was functioning properly. This paper presents the measured and calculated (CATHARE code version V15a mod 2.1) results of the test ...
The Coal Fired Combined Cycle (CFCC) is the unique powerplant concept developed under the leadership of the General Electric Company to provide a direct coal-burning gas turbine and steam turbine combined cycle powerplant. On the basis of previous studies and confirming work under this contract, General Electric continues to believe that the CFCC approach offers important advantages over alternate approaches: higher powerplant efficiency in the combustor temperature range of interest; reduced combustor/steam generator corrosion potential, due to low fluid-bed tube temperature (as contrasted to the air in tube cycle); and increased gas turbine bucket life from improved material protection systems. The objective of this program is to evaluate the coal fired combined cycle powerplant conceptual design, and to conduct a supporting development program. The supporting development is required for evaluating ...
Three inclined tubular digesters of 13- to 15-litre volume were operated at temperatures between 20 and 30 degrees C with hydraulic retention times of 10-15 days on pig slurry of 10%, 5% and 2.5% Total Solids content. Tube inclination of 16-20 degrees gave no scumming problems. Solids were retained, giving improved gas yields when compared with literature values for conventional stirred digesters. Solids retention is affected by the size of the digester exit and appears to be greater with slurry of low solids content. There is a link between the movement of solids and gas along, and out of, the digester which can lead to unstable oscillating gas production. Tracer studies showed soluble components of the slurry mixed throughout the whole volume of the digester in 25% of the hydraulic retention time or less. Solids moved in well dispersed plug flow. Gas production (both intrinsic and ...
Study was made on the city bus driven by the series hybrid system composed of a small ceramic gas turbine (100kW), generator and lead storage battery. Two driving modes were adopted, 10-driving mode and real driving mode assuming a certain bus route in Tokyo. The motor is driven mainly by generated power and additionally by battery power, however, the engine/generator system is controlled at an optimum operation point (driving mode and regenerating mode) with a maximum thermal efficiency considering depth of discharge. Design voltage of the battery had nearly no effect on fuel consumption, while its capacity as large as possible was desirable unless its weight has an adverse effect on the system. The real driving mode was lower in fuel consumption by 39% than the 10-driving mode. Since real fuel consumption is largely affected by recovery rate of regenerable energy, the operation point of the motor should be optimized according to driving mode. ...
In a PWR type reactor, a primary coolant circuit system using a steam generator is adopted in order to accelerate depressurization of a primary coolant circuit upon small rupture LOCA in which the pressure of the primary coolant circuit is moderately depressurized. A secondary coolant circuit depressurization valve is disposed to a main steam pipeline. The valve has a performance of automatically opening to remove heat by evaporation of water stored in SG for a short period of time when the pressure in the primary circuit is decreased to about 50kg/cm[sup 2] upon occurrence of LOCA or the like. Then, the secondary side of the SG is depressurized to about atmospheric pressure and gravitational water injection from a condensate tank is started. Further, a gas vent valve is disposed to a water chamber of the steam generator. The valve has a performance of automatically opening to discharge incondensible gas mixed to the ...
The US Environmental Protection Agency (EPA) conducted a cost-effectiveness (CE) analysis to estimate the incremental cost of complying with the proposed effluent limitation guidelines (ELGs) for the coastal oil and gas industry (EPA 1995a). EPA`s CE analysis calculates the pounds of each pollutant that would be removed if the chosen discharge option is selected. In 1993, EPA issued final ELGs for the offshore oil and gas industry and published an offshore CE analysis. The chemical characteristics of produced water from the offshore region are essentially the same as those of produced water from the coastal region. It was surprising, therefore, that EPA chose a much longer list of pollutants and generally stricter weighting factors for the coastal CE analysis. This report reviews the data, assumptions, and analyses used in EPA`s coastal CE analysis and identifies alternate data, assumptions, and analyses that could lead to ...
The helium-cooled HTGR (High Temperature Gas-cooled Reactor) will take an important position in the global energy strategy. It is expected to supply not only electricity but also high quality thermal energy for various industries and local utilities without exhausting any green house effect gas or acid rain gas. The key R and D issue of the HTGR is economical competitiveness, particularly against light water reactors. Due to the poor heat transfer of the single phase helium, the HTGR's volumetric power density is restricted to tenth of corresponding PWR's value so that increasing the power density by improving heat transfer is strongly desired. The standstill can be broken through by adopting gas-solid suspension medium. Its heat transfer performance is quite excellent. Its heat capacity can be increased drastically without excessive pressurization. Although the thermal radiation is a dominant heat ...
A high power (200KV), intense current density, low emittance (71mmmrad), high brightness (8x10{sup 10}A/m rad) electron beam was generated in the 10cm long, high-voltage-resistive multi-gap hollow cathode pseudospark chamber filled with 15pa nitrogen and driven by an improved pulse line accelerator. The beam was ejected with the 1mm diameter, the 2.2KA beam current, and the 400ns pulse length, and could propagated 20cm in the drift tube. At a distance of 5cm from the anode it penetrated consecutively an acid-sensitive discoloring film and a 0.05mm-thick copper foil both stuck closely, left 0.6mm and 0.3mm holes on them, respectively. That 10 shots on an acid-sensitive film produced a hole of 1.6mm at 7cm downstream of anode showed its good repeatability. After 60 shots the pseudospark discharge chamber was disassembled and observed that almost no destructive damage traces left on the surfaces of its various electrodes and insulators. But on ...
This study attempts to elucidate some of the effects of adding argon, neon and hydrogen to low pressure thermionically supported discharges used for plasma nitriding AISI M2 steel substrates. Four runs were performed at the same substrate temperature (550 C) and bias voltage (500 V), using the following gas mixtures: 8% N{sub 2} in Ar, 8% N{sub 2} in Ne, N{sub 2}+H{sub 2} in equal proportions, and N{sub 2} only. By careful control of the discharge parameters, most of the bombardment energy was transported to the substrates by 500 eV ions in all cases; these were mainly Ar{sup +} ions in the N{sub 2}+Ar run and N{sub 2}{sup +} ions in the other runs, notably by the action of Penning ionization in the N{sub 2}+Ne run. We found that the surface hardness was not significantly influenced by the type of ion delivering the bombardment energy, although we suggest that ions would need sufficient mass to cause (for example) ...
In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).
The growth of an oxide interfacial layer was recently found to increase the open-circuit voltage (OCV) and efficiency by up to 60 per cent in GaAs metal-semiconductor solar cells. Details of oxidation techniques to provide the necessary oxide thickness and chemical structure and using ozone, water-vapor-saturated oxygen, or oxygen gasdischarges are described, as well as apparent crystallographic orientation effects. Preliminary results of the oxide chemistry obtained from X-ray, photoelectron spectroscopy are given. Ratios of arsenic oxide to gallium oxide of unity or less seem to be preferable. Samples with the highest OVC predominantly have As(+3) in the arsenic oxide rather than As(+5). A major difficulty at this time is a reduction in OCV by 100-200 mV when the antireflection coating is vacuum deposited.
Adding capacity to coal-fired plants in small increments of an overall integrated program may be the solution to the 10-year lead time required for the construction of a new plant. A preliminary study evaluates the technical and economic feasibility of a modular natural gas and coal-fired combined-cycle power plant which can be installed in three distinct phases. The plant sizes are suitable for large industrial and utility applications. The Modular Block Power Plant (MBPP) concept offers the advantages of phase construction, lower capital cost, lower cost electricity, lower air emissions, lower water requirements, and reduced solid waste discharge. Other advantages include part load availability, reduced coal inventory requirements, and easier plant siting. 11 figures, 4 tables.
In the present investigation, the properties of plasma nitrided AISI 304 steel were studied by changing the presence of nitrogen in the gas mixture. The plasma nitriding was performed at temperature -560 deg C, pressure -4 mbar and duration 24 hours. The nitrided samples were characterized by evaluating the phase composition, micro hardness, and diffusion layer thickness. The phase analysis indicates the mixed phases of CrN and Fe_3N, Fe_3N and Fe_4N which has the highest intensity. The results show the glow discharge plasma nitriding in presence of N_2 (80 vol. %) and H_2 (rest) produced higher hardness as well as higher case depth. (author)
New results for two types of nano-size silicon, prepared via thermal vapour deposition either with or without a graphite substrate are presented. Their superior reversible charge capacity and cycle life as negative electrode material for lithium-ion batteries have already been shown in previous work. Here the lithiation reaction of the materials is investigated more closely via different electrochemical in situ techniques: Raman spectroscopy, dilatometry and differential electrochemical mass spectrometry (DEMS). The Si/graphite compound material shows relatively high kinetics upon discharge. The moderate relative volume change and low gas evolution of the nano silicon based electrode, both being important points for a possible future use in real batteries, are discussed with respect to a standard graphite electrode. (author)
The thermal analysis of a turbine stack discharging exhaust gases to the atmosphere is presented. The examined turbine stack belongs to a gas lift plant for oil extraction located in the Gulf area. The analysis has been performed because an overheating of the anchor flange/bolts and of the concrete foundation occurred and caused small cracks in the upper layer of the foundation. A qualitative thermal analysis of the stack has pointed out that the main cause of the overheating was the thermal radiation in the air-filled region underneath the stack bottom plate. Detailed calculations performed by using a CFD code (Fluent ver. 6.0.12), cross-checked with measurements taken from site, have shown that a significant reduction of the heat flux to the foundation could be obtained by filling the above mentioned air region with an insulating material. The benefits of this solution are prevailing over those achievable with the installation of external ...
Soufriere Hills Volcano had two periods of repetitive Vulcanian activity in 1997. Each explosion discharged the contents of the upper 0.5-2km of the conduit as pyroclastic flows and fallout: frothy pumices from a deep, gas-rich zone, lava and breadcrust bombs from a degassed lava plug, and dense pumices from a transition zone. Vesicles constitute 1-66vol.% of breadcrust bombs and 24-79% of pumices, all those larger than a few tens of m being interconnected. Small vesicles (few hundreds of m) in pumices are interpreted as pre-dating explosion, implying pre-explosive conduit porosities up to 55%. About a sixth of large vesicles in pumices, and all those in breadcrust bombs, are angular voids formed by syn-explosive fracturing of amphibole phenocrysts. An intermediate-sized vesicle population...
The SGTR project has been carried out within the fifth EURATOM Framework Programme (Contract No FIKS-CT-1999-0007). Its main objective was to provide an experimental database and to develop and/or verify models to support definition of accident management measures in the hypothetical case of a Steam Generator tube Rupture (SGTR) sequence. The project addressed both vertical and horizontal steam generator designs. This report summarises the main results obtained in the intermediate scale experimentation that addressed Western type steam generators. The specific goal of this test programme was to investigate aerosol retention in the break stage of the secondary side of a water-empty steam generator. The test matrix consisted of 12 tests that explored the influence of variables such as break type and orientation and inlet gas flow rate. This work was performed in the PECA facility of the Laboratory for Analysis of Safety Systems (LASS). Aerosol ...
Crankshafts of the pearlitic-sorbitic nodular cast iron type JUS NL.80 (similar to DIN GGG-80) heat treated to get a tensile strength of 820-900 GPa (i.e. a Vickers hardness of 268-295 HV) were plasma and ammonia gas nitrided. The glow discharge plasma nitriding was performed for 20 h at about 500degC in a gas mixture of 55% N{sub 2} and 45% H{sub 2}. The gas nitriding was performed for 28 h at 510degC in the ammonia gas. Evaluation of the nitrided surfaces was conducted by optical microscopy, X-ray diffractometry and microhardness measurements. Journal and crank pin dimensions and surface roughness were measured both before and after nitriding. Bending fatigue testing of crankshafts was performed using a fatigue testing rig. The fatigue limit was evaluated at 5.0x10{sup 6} cycles. The fractures happened at the transition radius of the journal with cracks starting beneath the ...
The purpose of this report is to determine if it is feasible to utilize the hot exhaust gasdischarged from gas turbines in direct applications. This report illustrates the technical feasibility and economic viability of using gas turbines in drying applications. The size of turbines in this investigation ranges from 2 MW to 10 MW. In addition, an implementation strategy has been developed to employ this new system. The method used to structure the scope of this undertaking is as follows: Step 1. Collecting information by contacting dryer manufacturer and companies drying different products. Information was also gathered by literature studies and the internet. Thomas register is a great tool when it comes to company and market searches. Step 2. Looking into if it is technically possible to use the exhaust gas directly into dryers. The parameters needed for these calculations were ...
This paper systematically introduces the supervision monitoring for radiation environment around the Guangdong Daya Bay and Ling Ao nuclear power station by the Guangdong Environmental Radiation Research and Monitoring Center. It includes the monitoring plan, methods, quality assurance, main results and conclusions. The results show that: (1) The gasdischarge have not caused any detectable impacts to the terrestrial and atmospheric environment since their operation; (2) "1"1"0"mAg could only be detected in seawater in the West Daya Bay in 1995 and 1997 and in sediments in 1997. The maximum annual average in seawater was 3.1 Bq/m"3, annual average of "1"1"0"mAg in sediments was 1.0 Bq/kg(dry). But it was always detectable in pearl oyster, gulfweed and cuttlefish in the West Daya Bay. The "1"1"0"mAg concentrations in halobios were relatively higher in 1994, 1996 and 1997. The maximum concentrations in pearl oyster, gulfweed and cuttlefish were ...
A zinc-air battery using zinc regeneration electrolysis with propanol oxidation as a counter electrode reaction is reported in this paper. It possesses functions of both zincate reduction and electrochemical preparation, showing the potential for increasing the electronic energy utilization. Charge/discharge tests and scanning electron microscopy (SEM) micrographs reveal that when a nickel sheet plated with the high-H{sub 2}-overpotential metal, cadmium, was used as the negative substrate electrode, the dendritic formation and hydrogen evolution are suppressed effectively, and granular zinc deposits become larger but relatively dense with the increase of charge time. The performance of batteries is favorable even if the charge time is as long as 5 h at the current density of 20 mA cm{sup -2}. Better discharge performance is achieved using a 'cavity-opening' configuration for the discharge cell rather than ...
In the next few decades, the probable strengthening of the greenhouse effect may bring about considerable changes in energy production and consumption, which depend on climate. It is presumed that some of the changes will occur even if the rise in greenhouse gas concentration will be reduced. Because the investments in energy production have a long-term influence, decision-makers should have an idea about the impact of the strengthening of the greenhouse effect on energy production and consumption in Finland. According to the results of this study, the effects of climate change on the total consumption and production of electricity will be limited. The structure of both electricity consumption and production will remain rather similar, the most important changes applying to hydro power. The consumption of heating electricity will decrease substantially. Because the non- climate-dependent sectors of electricity consumption (process industry and services) account for ...
The WEGA stellarator is used to confine low temperature, overdense (densities exceeding the cut-off density of the heating wave) plasmas by magnetic fields in the range of B=50-500 mT. Microwave heating systems are used to ignite gasdischarges using hydrogen, helium, neon or argon as working gases. The produced plasmas have been analyzed using Langmuir and emissive probes, a single-channel interferometer and ultra-high resolution Doppler spectroscopy. For a typical argon discharge in the low field operation, B=56 mT, the maximum electron density is n{sub e}{proportional_to}10{sup 18} m{sup -3} with temperatures in the range of T=4-12 eV. The plasma parameters are determined by using Langmuir probes and are cross-checked with interferometry. It is demonstrated within this work that the joint use of emissive probes and ultra-high resolution Doppler spectroscopy allows a precise measurement of the radial electric field. The ...
The study examined the possibility for fuel ignition by spark discharge caused by induction effects under high voltage transmission lines. Theoretical background information on capacitive spark discharges and fuel ignition processes is given. Laboratory experiments were conducted to test the dependence of fuel ignition on three parameters: impedance in discharge path, multiple discharges, and larger electrode shapes. The results of these tests are discussed in terms of fuel ignition possibilities under high voltage transmission lines.
Mitsubishi is now developing a next-generation Pressurized Water Reactor (PWR) which has the innovative feature of hybrid safety systems (optimum combination of passive safety system and active safety system) and passive core cooling by horizontal steam generators during Loss of Coolant Accident (LOCA). In order to confirm the capability of this passive core cooling system during LOCAs, the thermal-hydraulic tests of horizontal steam generator and the integral thermal-hydraulic tests simulating the LOCAs were performed. The thermal-hydraulic tests of horizontal steam generator consist of a single tube test and a multi-tubes test. On the basis of these test results, the heat transfer characteristics of steam-water two-phase flow with noncondensable gas along a long horizontal tube is understood and the heat transfer correlation including the effect of noncondensable gas is presented. ...
A series of measurements of O_3 yield in nuclear induced O_2 and O_2-SF_6 discharges created by bombardment with energetic particles from the "1"0B(n,#alpha#)"7Li reaction are reported. Continuous irradiation at dose ratios of 10"1"5-10"1"7 eV.cm"-"3.s"-"1 and pulsed irradiation (approx.10 ms FWHM) at a peak dose rate of approx.10"2"0 eV.cm"-"3.s"-"1 were conducted. At the lower dose rates, SF_6 addition generally increased the ozone yield, which at the high dose rates, SF_6 addition decreased the observed ozone concentration. A numerical model was developed and applied to experimental conditions. The steady-state ozone concentration was found to be limited by the reaction O_3"- + O_3 #-># 2O_2 + O_2"-. A simplified analytical model of steady-state conditions was used to predict model sensitivity to various parameters. In addition to dose rate effects, pressure and temperature effect on ozone production were discussed. The present study was extended to noble ...
This report introduces a microprocessor system composed of a Z-80 single-board computer controlling a gas-carburizing process. The system has 7 analogical input and output signals 24 switch signal-input and 12 switch signal-output signals, which are applicable for temperature, carbon potential, and mechanical-movement control of multipurpose sealed furnaces, or for mutiple-zone temperature, carbon potential, and mechanical-movement control of continuous gas carburizing furnaces; or for distributed control of pit-type carburizing furnaces. The setpoints of variables, such as treating time, temperature, carbon potential of carburizing period, carbon potential of diffusion period, depth of carburizing layer, P.I.D. etc., are entered by keyboard and stored into memories, and actual values are displayed by digital tubes. Furthermore, the fault of thermocouple, oxygen probe, or infrared CO/sub 2/ analyzer; carbon potential, or ...
Heat exchangers for high and ultrahigh temperatures are a need and a precondition to realise high efficient fossil fired power plants based on the so-called Externally Fired Combined Cycle (EFCC) or the Indirect Fired Gas Turbines (IFGT). The main target of both processes is to increase the thermal efficiency of existing power plants by approximately 25% resulting in the same decrease in fuel consumption and, therefore, in the same reduction of CO{sub 2} formation. The main activities of the MPA University of Stuttgart in this project is focused on the characterisation and qualification of the structural material of the ultrahigh temperature heat exchanger (UHTHE) necessary in the above mentioned processes. The influence of the temperature and load on the material behaviour have been analysed by means of tensile tests and creep tests. The effectiveness of different coating systems and the interaction between coating system and basic material was also investigated. ...
An experimental study of the hydrodynamics of a narrow channel was performed in order to obtain the heat transfer mechanisms and influences contributing to the flow regime transition from inverted annular to inverted slug flows for post dryout downflow. The experimental series consisted of both adiabatic and diabatic visualization tests over a wide range of fluid and thermal parameters. The system inlet gas velocities ranged from 0 to 14 meters per second while the inlet fluid velocities ranged from 1 to 3 meters per second. Full extent visualization of the flow regime was possible due to a quartz tube in tube construction with a clear heating fluid. Constant temperature heating of the freon was accomplished at bulk fluid temperatures above the critical heat flux temperature. For each hydrodynamic flow condition, one to three minuets of VHS-video filming was performed to acquire both flow regime and break-up length data. In ...
As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40{approximately}200 {micro}m depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue gas temperature. The excellent corrosion resistance of high [Cr+Ni+Mo] alloys such as Alloy 625 is explained by the ...
As the first step for development of the corrosion resistant superheater tube materials of 500 C, 100 ata used in high efficient waste-to-energy plants, field corrosion tests of six conventional alloys were carried out at metal temperatures of 450 C and 550 C for 700 and 3,000 hours in four typical Japanese waste incineration plants. The test results indicate that austenitic alloys containing approximately 80 wt% [Cr+Ni] show excellent corrosion resistance. When the corrosive environment is severe, intergranular corrosion of 40#approx#200 microm depth occurs in stainless steel and high alloyed materials. It is confirmed quantitatively that corrosion behavior is influenced by environmental corrosion factors such as Cl concentration and thickness of deposits on tube surface, metal temperature, and flue gas temperature. The excellent corrosion resistance of high [Cr+Ni+Mo] alloys such as Alloy 625 is explained by the stability ...
When steam generator tube denting was identified, steps were taken to retard the rate of corrosion and to develop corrective measures if possible. Techniques were developed to determine the exact shapes of the tubes, and procedures were devised to analyze resulting strain and operating stresses. Tube plugging criteria were established, and in twelve years of operation, there has been only one instance of a forced outage due to a tube leak.
Zircaloy fabrication plant manufactures all the necessary Zr-2 components like fuel canning tubes, calandria tubes and other rod and sheet products. This plant is having a capacity of producing about 4 lakh nos. of PHWR fuel tubes per annum. These tubes are seamless, thin walled with close dimensional tolerances and stringent mechanical properties. The plant has established all the facilities required to produce these tubes with required quality.
Products of a power plant flue gas desulfurization scrubber are discharged into a pond as sludge consisting of calcite (initial delta13C 3.2-3.8 per thousand), gypsum (initial delta34S 7.6-8.6 per thousand), and aqueous solution. Reducing conditions exist below a boundary that appears to move vertically as a function of changes in pond water level. Under reducing conditions, bacteria partially reduce aqueous sulfate to low-delta34S sulfide, consuming organic carbon and generating low-delta13C bicarbonate. Under oxidizing conditions, sulfide is converted to sulfate, leading to calcite dissolution, gypsum precipitation, and isotopic re-equilibration of remaining calcite with dissolved bicarbonate near the pond surface. The gypsum has delta34S near 6 per thousand, and calcite has delta13C as low as -1.7 per thousand; the changes from initial values correspond to predictions based on isotopic balance and reaction stoichiometry. The pond largely ...
The recent attempt to degassify a self contained liquid filled (SCLF) cable in Ontario Hydro is described. In September 1989, there was a high pressure alarm on one phase of a SCLF 115 kV cable circuit. The direct buried cable circuit is about 1,890 m long with two joints and was installed in 1968. Oil samples from the cable had 10 to 12% gas content with high levels of hydrogen, methane, and ethane, and very low levels of carbon monoxide, carbon dioxide, and acetylene. From these results it was concluded that the gas was generated by low energy electrical discharges and the paper insulation was not degraded. Various utilities and cable manufacturers were contacted to find if they had experienced similar problems. The cable duct oil was flushed and gasified and the successive oil samples were analyzed in order to locate the gassing site. The joints were examined and oil samples were taken through holes drilled in the cable ...
The 380 MW combined cycle gas turbine power station in Peterborough changed its water supply from town mains to high purity reverse osmosis permeate in October 2000. The high purity water is produced from secondary treated sewage effluent using advanced membrane technology. Alpheus Environmental and British Gas staff have recently completed a study of the power station's demineralization plant to identify the differences in operating costs associated with the change in feedwater. The results show that the ultrapure water produced after the change to a high purity feed is of improved quality and that the demineralization plant regeneration operating costs have been reduced by over 90%. The demineralization plant availability has increased from 78 to 98% enabling almost 20% more ultra pure water to be produced. The change in feedwater has also improved the local environment by significantly reducing the amount of waste chemicals ...
In order to investigate the effect of humidity on laminar burning velocity(S), the effect of humidity on the combustion reaction and radiation intensity was studied, taking account of dilution gases such as CO/sub 2/ and Ar which has the approximately identical characteristics to exhaust gas circulation(EGR) gas used to prevent NOx discharge from engines. According to the heat reaction theory, mean specific heat(C) of mixture, mean molecular weight(M) and adiabatic flame temperature(T) etc. were said to affect S but from experimental results, the effect of M and C could be ignored, compared with the effect of T. The relationship between S and H/sub 2/O, Ar of CO/sub 2/% in mixture of diluted gases was clarified. The effect of H/sub 2/O on S was mainly caused by changes of T. The effect of radical C/sub 2/, CH and OH on radiation intensity was similar to that of H/sub 2/O and Ar and the effect of H/sub 2/O on combustion was ...
To develop oxygen electrodes for rechargeable metal-air batteries, the electrochemical behaviour of gas-diffusion-type carbon electrodes loaded with Pr-Mn-Fe-based perovskite-type oxides was examined for the reduction and evolution of oxygen in 8 M KOH at 60 C. Among the oxides tested, Pr{sub 0.2}Ca{sub 0.8}Mn{sub 0.1}Fe{sub 0.9}O{sub 3} gave the highest electrode performances, e.g., current densities of 275 mA/cm{sup 2} (for oxygen reduction) and 225 mA/cm{sup 2} (for oxygen evolution) at -300 and +650 mV vs. Hg/HgO, respectively. The electrode performances were found to depend on both the catalytic activity of the oxides for H{sub 2}O{sub 2} decomposition reaction and the amounts of oxygen desorbed from the oxides. Furthermore, it was confirmed that the small zinc-air battery including the gas-diffusion-type electrode loaded with Pr{sub 0.2}Ca{sub 0.8}Mn{sub 0.1}Fe{sub 0.9}O{sub 3} showed good discharge and charge ...
The objectives of this paper are to document the physicochemical and aquatic toxicological quality of a beneficial-use produced-water discharge and its effect on a receiving stream in Wyoming. Fish and water-flea survival, growth, and reproduction tests indicated that the discharge and all other sampling stations passed the state effluent biomonitoring acute toxicity testing endpoints. while benthic macroinvertebrates were absent at the discharge point designated by the Natl. Pollutant Discharge Elimination System (NPDES), productive and reproducing populations were present at all other downstream and mixing-zone stations. This investigation confirmed the validity of the beneficial-use subcategory for this oilfield discharge.
In 1991/1992, VEAG decided to convert its 500 MW plants at Jaenschwalde and Boxberg to the latest state of technology. This even included the discharge of the cleaned flue gas through the existing cooling towers. The site of the flue gas desulphurization plant and also the existing cooling tower shells required routeing of the clean gas lines similar to the routes in the existing plants of RWE. The positive experience accrued with the pipework material `glass-fibre reinforced vinyl ester resin` has also led to the selection of this material here. The universally positive experience gained from existing clean gas lines via cooling towers by very different power station operators induced VEAG and its partners also to equip new construction operations in the new Federal states with this technology. (orig.) [Deutsch] In den Jahren 1991/1992 entschloss sich die VEAG, ihre 500-MW-Anlagen ...
Treatment chemicals are used in all facets of the natural gas industry (NGI) from well development through transmission and storage of natural gas. The multitude of chemicals used, combined with the dozens of chemical manufacturers and/or suppliers has lead to the availability of hundreds of possible chemical products. Because of the widespread use of chemical products and their numerous sources, the NGI needs access to consistent data regarding their effectiveness and potential environmental impacts. The objective of this work was to evaluate the effectiveness and potential environmental impacts of, chemical products used in the NGI. This assessment was initially focused on biocides and corrosion inhibitors and their use in the gas production, storage and transmission facilities, The overall approach was obtain the necessary data on chemical use and effectiveness directly from the oil and gas industry, ...
Waste is a heterogeneous fuel, often with high levels of chlorine, alkali and heavy metals. This leads to much more severe corrosion problems than combustion of fossil fuels. The corrosion rates of the materials used can be extremely high. Materials used for heat transferring parts are usually carbon steel or low alloyed steel. These are significantly cheaper than other steels. Austenitic stainless steel is also used, but is often avoided due to its sensitivity to stress corrosion cracking. More advanced materials, such as nickel base alloys, can be used in extremely aggressive environments. Since these materials are expensive and do not always have sufficient mechanical properties, they are often used as coatings on carbon steel tubes or as composite tubes. A new method, which shows good results at the first tests in plants, is electroplating with nickel. Plastic materials can be used in low temperature parts if the temperature does not exceed ...
discharges. Proposed Stormwater ELG from Construction Sites - EPA has proposed effluent limitations guidelines (ELGs) and new source performance standards (NSPS) to control...
Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube ...
Permian coal and Triassic mudstone from the Ordos Basin were pyrolyzed in a closed system using a gold tube technique. Carbon and hydrogen isotopes of the gases generated from pyrolysis were compared to Mesozoic gases in the basin to interpret the origin, maturity and any mixing of gases. Maturation trends for thermogenic methane from both coal and lacustrine kerogens in our experiment were found to be independent of heating rate, allowing their use for determination of gas provenance. Gases from a tectonically stable area like the Shanbei slope are derived mainly from Yanchang lacustrine kerogen, and gases in tectonically active areas consist of mixtures of coal-derived gases and oil-associated methane from deeply buried formations, as well as oil-associated gases and biogenic gases from ...
Vapor-liquid equilibria, by head-space gas-chromatographic analysis of the equilibrated vapor phase directly withdrawn from the equilibration apparatus, and molar excess volumes, V[sup E], by means of a vibrating-tube densimeter, of binary mixtures containing thiaalkanes or dithiaalkanes with n-alkanes or cyclohexane, were determined at 298.15 K. The excess molar Gibbs free energies, GE, of the examined mixtures were obtained by a least-squares treatment of the equilibrium data. The GE and V[sup E] values indicate that the steric effect exerted by the alkyl groups adjacent to the S group causes a regular decrease of the G[sup E] (or V[sup E]) with increasing the number of alkyl groups in the thiaalkane. A tentative approach, based on an additivity scheme of surface interactions combined with the scaled particle theory, is presented to estimate the energies of solvation in terms of group contributions.
The effects of O and C ion implantation with different implantation doses on the yellow luminescence (YL) from unintentional doped n-type GaN have been studied by the photoluminescence (PL) spectra. O and C ions were implanted in the GaN samples with different doses from 1.0 x l013 to 1.0 x l017cm-2. Post-annealing was done in a quartz open-tube furnace under flowing N2 gas for 30 min at 950 degree C. By comparing with N ion implanted samples, it is assumed that different deep-level centers involving in the YL were produced in GaN after O and C ion implantation. In addition, with a dose of 1017 cm-2, the concentration of deep C centers involving in the YL was enhanced markedly. (authors)
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.
The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).
The technology for flue gas desulfurization (FGD) with seawater is widely adopted by coal-fired power plants in coastal areas. SO2 in the flue gas is absorbed by alkaline seawater and transfered in aqueous phase as sulfite (SO3(2-)), and most SO3(2-) is transformed to sulfate (SO4(2-)) after an aeration process. The remaining SO3(2-) in the seawater discharged to sea area may be harmful to marine organism because of its biological toxicity, thus it is necessary to determine the concentration of SO3(2-) in the seawater for desulfurization. In this study, the method of determination of SO3(2-) in the seawater by ion chromatography was investigated. The separation was achieved on an IonPac AS14A column with 14 mmol/L NaOH-12 mmol/L Na2 CO3 solution as the mobile phase at a flow rate of 1.2 mL/min, and the detection was performed by a pulsed amperometric detector. Formaldehyde was added as a protective agent when sampling ...
The objectives of this program are to evaluate the Coal Fired Combined Cycle (CFCC) power plant conceptual design and to conduct supporting development programs for pressurized fluidized bed technology advancement in combustion/steam generator, gas turbine and hot gas cleanup technologies. The Coal-Fired Combined Cycle is the unique power plant concept developed under the leadership of the General Electric Company to provide a direct coal-burning gas turbine and steam turbine combined-cycle power plant. The advantages of the combined cycle for higher efficiency and the potential of the pressurized fluidized bed combustor improvements in emissions could offer a new and attractive option to the electric utility industry. The CFCC approach provides for cooling the fluid bed combustor through the use of steam tubes in the bed which supply a steam turbine generator. The partially cooled combustion gases ...
Gas evolution in aluminum electrolytic capacitors constitutes one of their main drawbacks in comparison to other types of capacitors lacking a liquid electrolyte. In this respect, one of the most common causes of failure shown by liquid electrolyte capacitors is electrolyte leakage through the seal or even explosions produced by internal pressure buildup. In order to prevent these hazards, some substances, known as depolarizers, are usually added to the capacitor electrolyte with the purpose of absorbing the hydrogen evolved at the cathode (1, 2). Although the gas evolution problem in electrolytic capacitors has been known for a long time, there is a lack of literature on both direct measurements of the gas evolved and assessments of the amount of depolarizer active for the hydrogen absorption process. Aluminum electrolytic capacitors of 100..mu..F and 40V nominal voltage, miniature type (diam 8 mm, height 18.5 mm), were ...
Results are presented of experiments on partial discharge in liquid nitrogen, including insulation breakdown characteristics of liquid nitrogen, partial discharge characteristics of composite insulation systems, lifetime of polymer films, impulse breakdown of polymer films in liquid nitrogen, etc. The partial discharge characteristics of liquid nitrogen are examined with increasing liquid-nitrogen pressure. It is concluded that a composite insulation structure of polymer film and liquid nitrogen can be used as effective electrical insulators at cryogenic temperatures.
Results from scanning electron microscopy, Fourier transform infrared spectroscopy and the measurement of thermally stimulated current show that a high density of the physical defects and the chemical defects are introduced into the surface of the silicone rubber plates after they are treated by corona discharge plasma. These defects behave electrically as shallow electron traps, leading to the formation of a uniform discharge in air at higher pressure when the corona-modified silicone rubber is used in dielectric barrier discharge.
Permian coal and Triassic mudstone from the Ordos Basin were pyrolyzed in a closed system using a gold tube technique. Carbon and hydrogen isotopes of the gases generated from pyrolysis were compared to Mesozoic gases in the basin to interpret the origin, maturity and any mixing of gases. Maturation trends for thermogenic methane from both coal and lacustrine kerogens in our experiment were found to be independent of heating rate, allowing their use for determination of gas provenance. Gases from a tectonically stable area like the Shanbei slope are derived mainly from Yanchang lacustrine kerogen, and gases in tectonically active areas consist of mixtures of coal-derived gases and oil-associated methane from deeply buried formations, as well as oil-associated gases and biogenic gases from shallow depth. The thermal maturity of the C{sub 2} and C{sub 3} gases is estimated to cover an equivalent vitrinite reflectance range from 0.7% to 1.2% R{sub ...
A gas-fired boiler plant comprises a burner bed extending over a flat surface and heat exchanger pipes arranged above the burner bed, parallel to the said surface. The heat exchanger tubes comprise pipes equipped with a pluraltiy of flat ribs which extend substantially radially from the said pipes and which are provided in space arrangement over the length of the said heat exchanger pipes. The ribs are provided with bent-off portions. The hot flue gases rising from the burner bed flow through the gaps formed between the said ribs and pipes. In order to improve both the convective heat transmission and the utilization of the radiant heat, the bent-over edges are inclined, at least partly, relative to the surface of said burner bed, the arrangement being selected in a manner to ensure that bent-over portions point towards the burner bed and the rising flue gased are guided around the pipes along a roughly semi-circular path.
Within the scope of the German reactor safety research the thermohydraulic computer code ATHLET which was developed for accident analyses of western nuclear power plants is more and more used for the accident analysis of VVER-plants particularly for VVER-440,V-213. The experiments with the HORUS-facilities and the analyses with the ATHLET-code have been realized at the Technical University Zittau/Goerlitz since 1991. The aim of the investigations was to improve and verify the condensation model particularly the correlations for the calculation of the heat transfer coefficients in the ATHLET-code for pure steam and steam-noncondensing gas mixtures in horizontal tubes. About 130 condensation experiments have been performed at the HORUS-II facility. The experiments have been carried out with pure steam as well as with noncondensing gas injections into the steam mass flow. The experimental simulations are characterized as ...
Corrosion in drilling and well stimulation is described in relation to acid corrosion inhibition, acid inhibitors, acetylenic inhibitors, synergistic blends, metallurgy, wellbore tubulars, coiled tubing, and high alloy tubular materials. Acidizing is a procedure for stimulating oil and gas wells. Factors that have an important influence on the reaction rate and the way in which acid reacts with rock include temperature, acid concentration, acid volume, injection velocity, acid viscosity, and fluid loss properties of the formation. The cost of drill pipe failures are $1 per fot of hole drilled, which is a significant fraction of the drilling cost. Steps in a test procedure are listed, as well as factors which determine the extent of acid corrosion in a given situation including acid type and strength, metal type, temperature, contact time; pressure, and volume/surface area ratio. Underbalanced drilling is a method for completing oil and ...
A safety analysis code to design a pressurized water reactor and to obtain the licences including entire proprietary rights is under development in domestic research and development project. The purpose and scope of this report is to develop the flow regimes related models for inter-phase friction, wall frictions, wall heat transfer, and inter-phase heat and mass transfer in two-phase three-field equations. In order to choose choose the flow regime criteria, we have investigated various exiting best-estimate T/H codes in this chapter 2. They are the RELAP5-3D, TRAC-M, CATHARE, MARS codes. Around 500 references used in these codes have been collected and reviewed. Also we have investigated eleven papers in detail. In chapter 3, based on the selected flow regimes, the flow regime maps for a gas-liquid flow in horizontal and vertical tubes have decided including the mechanisms of flow regime transition regions. Conclusively, the process will be ...
The device is made by a tool at the end of a flexible cable, a motor for the rotation of the flexible, a linear drive with a guide for it between the winder and the tube.
The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).
A line-to-plate reactor was set-up in the experimental study on the application of nanosecond pulsed corona discharge plasma technology in environmental pollution control. Investigation on the attenuation and distortion of the amplitude of the pulse wave front and the discharge image as well as the waveform along the corona wire was conducted. The results show that the wave front decreases sharply during the corona discharge along the corona wire. The higher the amplitude of the applied pulse is, the more the amplitude of the wave front decreased. The wave attenuation responds in a lower corona discharge inversely. To get a higher efficiency of the line-to-plate reactor a sharp attenuation of the corona has to be considered in practical design.
Object: To limit the discharge amount of reactor water in a primary system at the time of scram to prevent excessive outflow of reactor water outside the system. Structure: A signal from an upper limit position indicator detects the fact that control rods are completely inserted when the reactor is urgently stopped and the detection signal causes a valve in an outflow line of the discharge water from a control rod driving mechanism to be closed to limit the amount of discharge flown into the scram discharge vessel, thus preventing outflow of reactor water in the primary system after the scram has been initiated. (Kamimura, M.).
An advanced experimental technique has been developed to simulate two-phase flow behavior in a light water reactor (LWR). The technique applies three kinds of methods; (1) use of sulfur-hexafluoride (SF6) gas and ethanol (C2H5OH) liquid at atmospheric temperature and a pressure less than 1.0MPa, where the fluid properties are similar to steam-water ones in the LWR, (2) generation of bubble with a sintering tube, which simulates bubble generation on heated surface in the LWR, (3) measurement of detailed bubble distribution data with a bi-optical probe (BOP), (4) and measurement of liquid velocities with the tracer liquid. This experimental technique provides easy visualization of flows by using a large scale experimental apparatus, which gives three-dimensional flows, and measurement of detailed spatial distributions of two-phase flow. With this technique, we have carried out experiments simulating two-phase flow behavior in a single-channel ...
The objective of the first project period is to: make a study into materials suitable for the non-premix radiant burners (NPRB); choose the materials for the construction; make proposals for the design of the NPRB; test the different proposals with a CFD-model. In pursuit of finding a suitable material it is necessary first to estimate the maximum temperature that will occur in the burner. It has been estimated that the maximum adiabatic flame temperature will be about 2400-2500 K. The maximum temperature in the burner will of course never reach this level. A more realistic temperature was estimated to 2100-2300 K. The final choice was made after having contacted some of the leading producers. It was possible to find one producer that could produce burners of one of the suggested materials, zirconia. Several construction ideas for the NPRB have been discussed and some of them tested with a CFD-model. The proposed burner concept has been modified in order to obtain a homogenous ...
Washboard (WB) modes (Smeulders P et al 1999 Plasma Phys. Control. Fusion 41 1303) are a very common edge instability regularly observed in the H-mode regime in JET. They are detected as (normally several) bands of continuously fluctuating magnetic activity rotating in the direction of the electron diamagnetic drift with typical frequencies in the range of 10-90 kHz. The time evolution of the WB mode frequency is found to follow qualitatively the evolution of the electron temperature measured near the pedestal top, probably due to the strong diamagnetic drift associated with the large pedestal gradients. Evidence for their involvement in the pedestal and ELM dynamics will be presented. Increasing WB mode amplitude is correlated with an increase in the time between consecutive type-I ELMs. In situations in which a sudden increase (decrease) of WB mode activity is observed, the build-up of the pedestal temperature (and, linked to this, also of the pedestal pressure) of the electrons is ...
During reproduction in flowering plants, pollen grains form a tube that grows in a polarized fashion through the female tissues to eventually fertilize the egg cell. These highly polarized pollen tubes...Full Text Available
Experimental results are presented for a new and unique heat transfer augmentation technique in tubes. The technique consists of inserting a porous mesh structure into the flow passage of the tube. Due to the increased degree of turbulence, both the singl...
In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.
In this work, amorphous hydrocarbon (a-C:H) film deposition on metallic mirrors was studied during working shots in tokamak T-10 and at exposure in Ar/CHD3/D2 dc magnetron discharge in a special laboratory high vacuum setup. Analysis of film composition (including hydrogen content) was carried out using nuclear physical methods. Thickness and optical parameters (refractive and extinction coefficients) of the films were estimated by ellipsometry. Laboratory films can be characterized as soft a-C:H films in comparison with hard tokamak films (? = 1.2 and 1.8 g/cm3, respectively). For the first one, a linear dependence of deposition rate on mirror temperature was observed in a wide temperature range. The addition of methane into initial Ar/D2 magnetron gas mixture leads to an increase of deposition rate. The data obtained should be taken into account to prevent hydrocarbon film formation on the surface of first mirrors in ITER.
A theoretical model is presented to describe the electromagnetic, heat transfer and fluid flow phenomena within a magnetron plasma torch and in the resultant plume, by using a commercial computational fluid dynamics (CFD) code FLUENT. Specific calculations are presented for a pure argon system (i.e., an argon plasma discharging into an argon environment), operated in a turbulent mode. An important finding of this work is that the external axial magnetic field (AMF) may have a significant effect on the behavior of arc plasma and thus affects the resulting plume. The AMF impels the plasma to retract axially and expand radially. As a result, the plasma intensity distribution on the cross section of torch seems to be more uniform. Numerical results also show that with AMF, the highest plasma temperature decreases and the anode arc root moves upstream significantly, while the current density distribution at the anode is more concentrated with a higher peak value. In ...
Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (?1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with three important features: (1) the plasma target is hot and confined during a few 'inertial confinement times'; (2) the ions of the main part of the beam are magnetized and entrapped around the pinch plasma target for a period longer than the characteristic time of the plasma inductive storage system and (3) ion-ion collisions (both fusion collisions, due to head-on impacts and Coulomb collisions) are responsible for neutron emission. Analysis has shown that one of the ways for ...
Direct current (DC) glow discharge plasma nitriding was carried out on three selected surface-roughened AISI 304 stainless steel samples at 833 K under 4 mbar pressures for 24 h in the presence of N{sub 2}:H{sub 2} gas mixtures of 50 : 50 ratios. After plasma nitriding, the phase formation, case depth, surface roughness, and microhardness of a plasma-nitrided layer were evaluated by glancing angle x-ray diffractogram, optical microscope, stylus profilometer, and Vickers microhardness tester techniques. The case depth, surface hardness, and phase formation variations were observed with a variation in initial surface roughness. The diffraction patterns of the plasma-nitrided samples showed the modified intensities of the {alpha} and {gamma} phases along with those of the CrN, Fe{sub 4}N, and Fe{sub 3}N phases. Hardness and case depth variations were observed with a variation in surface roughness. A maximum hardness of 1058 Hv and a case depth of ...
A brief description of a method for producing relatively intense molecular negative ion beams for the difficult Group IIA elements is given which offers considerable improvement in terms of source operation and beam intensity stability over other methods conventionally utilized. It is particularly suited for use in cesium plasma sources such as the Aarhus geometry and axial geometry versions of the source. The method utilizes H/sub 2/ source feed gas for the production of a hydrogen-rich plasma discharge which sputters a negatively biased probe made of elemental or copper alloy material. Negative ion beams of MgH/sub 3//sup -/>=12 ..mu.. A have been realized during routine operation of the 25 MV tandem accelerator. Negative ion beam intensity data, typical source operational parameters, and examples of mass spectra associated with their production are given. Interesting intermetallic molecular negative ion beams consisting of the particular ...
This paper deals with electron flux densities and electron energy flux densities in positive column discharges. Recent kinetic calculations by Uhrlandt and Winkler have revealed the interesting physical phenomenon of radially inward directed energy flux densities in positive column plasmas. We have used a self-consistent positive column model, based on an accurate and highly detailed Monte Carlo code, to study this effect in more depth. The results of this study show a rather complex physical picture of electron particle and energy flux densities. Electrons with low energies usually exhibit radially outward directed particle and energy flux densities. At energies above the threshold for electronic excitation particle and energy flux densities are usually inward directed. Only close to the wall, at total energies above the wall potential energy, do these flux densities point towards the wall. The thickness of this 'wall loss region' scales with the ...
Production of hydrogen sulfide in produced waters due to the activity of sulfate-reducing bacteria (SRB) is a potentially serious problem. The hydrogen sulfide is not only a safety and environmental concern, it also contributes to corrosion, solids formation, a reduction in produced oil and gas values, and limitations on water discharge. Waters produced from seawater-flooded reservoirs typically contain all of the nutrients required to support SRB metabolism. Surface processing facilities provide a favorable environment in which SRB flourish, converting water-borne nutrients into biomass and H{sub 2}S. This paper will present results from a field trial in which a new technology for the biochemical control of SRB metabolism was successfully applied. A slip stream of water downstream of separators on a produced water handling facility was routed through a bioreactor in a side-steam device where microbial growth was allowed to develop fully. This ...
Some examples are given of design adaptations, e.g. U-bend support, tube spacer grid, flow distribution baffle, triangular tube pitch, tube-tubeplate sheet connection, which reduce the tendency to various types of corrosion (stress corrosion cracking, tube denting, tube wastage, intergranular cracking). A basic diagram of the secondary circuit is shown. Oxygen, corrosion product and impurity control in the secondary circuit is described. (E.J.). 19 figs., 6 refs.
Steam generator tube denting is primarily caused by build-up of corrosion products at the tubesheet and the tube support plates. The mechanism of dent growth and the identification of tubes which should be removed from service have been studied. The practical outcome has been to prevent in-service tube leaks and to avoid unnecessary plugging of large numbers of tubes. A finite element study of tubesheet deformation (of pulled leaking tubes from reactors) was undertaken. Profilometry results for characterizing dents are given. Although several modifications have been made the high resolution profilometry system performance and the results obtained have proved satisfactory. (U.K.).
Carbon nano tubes are easily produced in macroscopic quantities, however their characterisation and possible applications are still rather limited. We have developed a new method to make aligned nano tube films which open new opportunities, not only for basic research but also for eventual applications. With this method the tubes can be aligned either parallel or perpendicular to the surface. We give a short review of the microscopic properties of single tubes and the bulk properties of the aligned films. (author). 24 refs., 6 figs.
Experiments were conducted to study the condensation heat transfer characteristics of horizontal enhanced tubes. In the current experiment, six different enhanced tubes, including 26, 40 fpi low fin tubes and four three-dimensional-fin tubes, were tested. The working fluid used in the experiment was HCFC-22. Data were presented in the form of overall heat transfer coefficient at three working pressures, namely 1.32, 1.47 and 1.62 Mpa. In addition, the condensing heat transfer coefficients for the test tubes were obtained from the Wilson plot technique.
This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ideal ...
This paper describes Automatic Refueling Planning System (ARPS) for a nuclear power station using Genetic Algorithms (GA) and a Simulated Annealing (SA). ARPS has been developed and verified by applying to the Fugen nuclear power station (NPS), which is a 165MWe, heavy water-moderated, boiling light water-cooled, pressure tube-type reactor developed by JNC utilizing mainly uranium and plutonium mixed oxide (MOX) fuel. Fuel loading patterns have been managed independently in the Fugen NPS since the initial core. A planning of an adequate fuel loading pattern on each operational cycle needs one to two months even for expert core management engineers, for the reason that it has multi-objective optimization and nonlinear problems. In order to achieve the optimum fuel loading pattern and a fuel cost reduction, ARPS has been developed by JNC and CRC Solutions Corporation for the last five years. ARPS firstly generates several thousand fuel loading patterns with GA at ...
In Japan, the development of next-generation Light Water Reactor has been launched since April 2008. The development program will be completed in 2015. The purpose of development is to cope with the replacement for existing nuclear power plants after 2030 in Japan and the expanding demand for nuclear power in the world; 'Nuclear Renaissance.' The reactor also aims to be global standard at around 2030. The requirements for global standard and domestic users have been investigated through the feasibility study of past 2 years, 2006-2007, and six innovative features or 'Core-Concepts' were established as follows. A) Reactor core system with uranium enrichment above 5% for significant decrease of spent fuel discharge and prominent higher availability B) Long-life materials and innovative water chemistry technologies for 80 years plant lifetime and significant reduction of occupational dose C) Seismic isolation technologies to standardize plant design independent from ...
Nitriding leads to improved tribological and corrosive properties of iron alloy components. In order to study the effect of plasma nitriding parameters on the structure of compound layer and diffusion zone, a systematic variation of process parameters, temperature and process gas atmosphere has been carried out. Metallographic inspection, X-ray diffraction and glow discharge optical spectroscopy analysis (GDOES) were used in this investigation. The results clarified that depending on the amount of nitrogen in the gas atmosphere nitrided layers with and without compound layer can be generated in the surface of M2 tool steel for temperatures from 350 C to 500 C. For plasma nitriding in 5 vol.% Nitrogen and 95 vol.% Hydrogen no compact compound layer was formed. The gas mixture of 76 vol.% Nitrogen resulted in compound layer formation for all temperatures from 350 C to 500 C. X-ray phase analysis indicated ...
The effect of ultrasound waves, airflow and combined ultrasound with the airflow on the thermal instability suppression of a hollow needle-to-plate electrical discharge was studied experimentally. To evaluate the thermal instability suppression we used the V-A characteristics of the discharge in stationary air, with ultrasound applied in stationary air, and finally when the airflow was supplied into the discharge through the needle without and with ultrasound application. To illustrate the effect of ultrasound, airflow and combined ultrasound with airflow on the discharge thermal instability suppression we also studied the discharge ozone production. We found that in stationary air the application of ultrasound only slightly suppresses thermal instability. A substantial increase of ozone generation was not detected. Application of the airflow through the needle suppressed ...
PurposeHistorically, a chest tube or drain has been left following a thoracic operation to allow drainage of air or fluid in the postoperative period. However, in...Full Text Available
Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test ...
Ozone production in a negative corona discharge has been studied experimentally at atmospheric pressure in mixtures of N_2O+O_2 at ambient temperature. Ozone formation was found to be dramatically reduced with increase in the content of N_2O in the mixture. The reaction of O("1D) with nitrous oxide is the most likely process reducing the rate of ozone generation. A considerable decrease in the mean discharge current at a constant voltage was also observed with increasing content of nitrous oxide in the mixture and is attributed to the formation of anions in the discharge. The low values of the calculated mobility of negative charge carriers in the drift region of the discharge is caused by the formation of O"- #centre dot# (N_2O)_n and NO"-#centre dot#(N_2O)_n cluster anions in the drift region of the negative corona discharge.
In June 2003, we conducted a two-part field exercise to examine biogeochemical characteristics of water in the lower Mississippi river during the 4 days prior to discharge and in the Mississippi river plume over 2 days after discharge. Here we describe the fates of materials immediately after their discharge through Southwest Pass of the Mississippi delta into the northern Gulf of Mexico. Changes in surface water properties immediately after discharge were much larger and more rapid than changes prior to discharge. Total suspended matter (TSM) declined, probably due to sinking, dissolved macronutrients were rapidly diminished by mixing and biological uptake, and phytoplankton populations increased dramatically, and then declined. This decline appeared to begin at salinities of approximatel...
Electrochemical discharge machining (ECDM) is a promising hybrid process for high-performance machining of non-conductive glass. ECDM drilling has been found to have different characteristics and material removal mechanisms in discharge regime (less than 300??m in depth) and hydrodynamic regime (more than 300??m in depth); however, these regimes are never separately modeled in existing ECDM models, which leads to large prediction error, especially at low applied voltages and high machining depths. Until now, no model is particularly designed for discharge regime, where most material is removed. In this paper, a finite element based model for ECDM drilling in discharge regime is presented. Material removal subjected to a single spark was simulated using finite element method. The drilling d...
The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the ...
A 12-month program was conducted to advance the technology of the Electrical Discharge Machining (EDM) process to be applicable to the stringent requirements of gun barrel boring and rifling. The type of barrels employed in the test were .220 swift gun ba...
The report details the economic impact of two alternative regulatory options; a Treated Discharge Option and a Zero Discharge Option on facilities that would have to comply with the regulations as part of the reproposal of effluent limitations and standar...
The report analyzes the cost-effectiveness of two alternative regulatory options: A Treated Discharge Option and a Zero Discharge Option. The report compares the total annualized cost incurred for each of the two regulatory options to the corresponding ef...
Through the analysis of the relations between "3H monitoring results of sea water in West Daya Bay carried out by Guangdong Environmental Radiation Research and Monitoring Center (GERC) from 1994 to 2000 and the quantity of liquid "3H discharges made by Guangdong Nuclear Power Station (GNPS), the function has been found by fitting to describe the relation between "3H average concentrations (hereafter as to average concentration or concentration) for all sampling points at the same time and the quantity of liquid "3H discharges. "3H instantaneous concentrations or yearly average concentration in West Daya Bay can be estimated conveniently by using this function corresponding to either actual discharges or supposed discharges (the way for hydrodynamic calculation) from the GNPS's yearly "3H liquid discharge. The results have shown that the general influences both actual ...
The device is designed for automatic testing of the degree of discharge of tractive storage batteries (AB) for electric loaders, electric cars and electric ore locomotives. The basic electrical schematic of the device is cited.
Experimental investigation was carried out for friction factor and heat transfer coefficient in the case of a rotating tube with a twisted-tape insert for heat transfer augmentation. The data obtained were compared with existing data for a stationary tube with a twisted-tape insert. It has been observed that the enhancement in heat transfer offsets the rise in friction factor due to rotation, with respect to a plain tube under stationary conditions. A correlation has been proposed for the data obtained.
Small droplets of organic diazides investigated by C.K. Law and coworkers burn in hot gas at 1 atm with rates inversely proportional to the droplet diameter presumably owing to leading chemical reaction proceeds in gas phase. These burning rates are obviously much lower than those obtained by extrapolation of the results measured for the some substances in glass tubes (at pressure of about 10{sup -2}-10{sup -1} atm, and temperature 0-100 deg C) on the burning conditions of the droplets. Kinetic constants estimated using Zel`dovich equation for the burning rate in gas phase and Semenov relation for delay time of the droplets micro-explosion in liquid phase are about the same: E {approx_equal} 0.17 MJ/mol, log{sub 10}k{sub o} {approx_equal} 15(S{sup -1}). In both of the cases the leading chemical reaction is supposed to be of the first order. Landau instability is assumed to be reflected in distortion of ...
Transverse glow discharges in supersonic air and methane flows are studied both experimentally and theoretically. The experiments show that a diffuse volume discharge filling the whole cross section of the flow can easily be initiated in air, whereas a diffuse discharge in a methane flow shows a tendency to transition into a constricted mode. The electron transport coefficients (mobility and drift velocity) and the kinetic coefficients (such as collisional excitation rates of the vibrational levels of a methane molecule, as well as dissociation and ionization rates) are calculated by numerically solving the Boltzmann equation for the electron energy distribution function. The calculated coefficients are used to estimate the parameters of the plasma and the electric field in the positive co...
During spring and autumn, the total number of amoebae and the number of acanthamoeba species able to grow at 37 degrees C were determined in six thermally polluted factory discharges and the surrounding surface waters. The isolated Acanthamoeba strains were studied for growth in axenic medium, cytopathic effect in Vito cell cultures, and virulence in mice. Although more amoebae were isolated in autumn, the number of Acanthamoeba species was lower than in spring, when the percent of pathogenic strains among the isolates was highest. Higher concentrations of amoebae were found in warm discharges, and more virulent strains occurred in thermal discharges than in surface waters.
It is experimentally demonstrated that a relatively strong ion-rich sheath formed at a fixed negative bias of the grid can be changed to a rather weak ion sheath (sheath potential weakly retards electrons) only by increasing the discharge voltage in the system. At sufficiently high negative grid bias, an increase of discharge voltage enhances the ion collection current at the grid. An explanation is put forward in support of this experimental observation. A slight density enhancement with a fall in plasma electron temperature is also observed with the increasing negative grid bias. (authors)
For users and manufacturers affected by unwanted electrostatic discharges, the publication of standards concerning the control of such discharges is a great improvement and helps to prevent unwanted electrostatic discharges in potentially explosive atmospheres as well as around electrostatically sensitive devices. There are, for instance, handbook-like documents giving recommendations to help set up effective electrostatic suppressing measures and programs. Another group of standards focuses on certain products and processes and is, thus, more specific. A third group deals with test methods and specifications to help manufacturers develop products that are safe. It also helps in comparisons with other products and thus meets the customer's real needs. To assist manufacturers and customers ...
A multielement apparatus for the removal of aerosols formed in the vitrification of simulated high-activity accident wastes from the decommissioned nuclear power plant A-1 has been designed, manufactured and tested. The apparatus consists of two cooling and condensing steps connected in series, and of five filtration steps also connected in series. The five filtration steps allowed to achieve a decontamination factor of 1x10"5 in the case of removal of a NaCl("2"4Na) testing model aerosol. The decontamination factor for removal of the cesium aerosol by the whole apparatus was 3.3x10"6. In the first filtration step the aerosols are removed by the cartridge with a filtration fabric made of polyethylene fibers, in the second step by the cartridge with a granulated natural material, in the third step by the cartridge with glass-fiber filtration paper, in the fourth and fifth steps by the cartridge with high-efficiency filtration paper made of glass microfibers. In the ...
During earlier work rapid and highly sensitive Jet-REMPI (resonance-enhanced multiphoton ionization) mass spectrometry was applied for monitoring the effluent from thermal treatment of a filter dust during a de novo test under laboratory conditions. The sample, from ESP-Field 2 of an iron ore sintering plant, was already loaded with dioxins ({sigma}PCDD/F = 132 ng/g), their precursors (PCBz, PCPh) and other products of incomplete combustion. Heating filter dust in a temperature window 200-350 C under a flow of air results in further formation of these pollutants. As described elsewhere, on-line detection was mostly carried out using a non-selective ionization mode, to measure a wide range of compounds simultaneously. The changes of output suggest that the reaction products increase in chlorination level with time. Another explanation is that higherchlorinated compounds appear later as a consequence of lower volatility and stronger adsorption. However, due to mass spectrometric ...
Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with {sup c}losure laws{sup .} Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take into account ...
Three-dimensional computer simulation and analyses of the horizontal steam generator thermal-hydraulics of the WWER 1000 nuclear power plant have been performed for 50% and 75% partial loads, 100% nominal load and 110% over-load. Presented results show water and steam mass flow rate vectors, steam void fraction spatial distribution, recirculation zones, swell level position, water mass inventory on the shell side, and other important thermal-hydraulic parameters. The simulations have been performed with the computer code 3D ANA, based on the 'two-fluid' model approach. Steam-water interface transport processes, as well as tube bundle flow resistance, energy transfer, and steam generation within tube bundles are modelled with "closure laws". Applied approach implies non-equilibrium thermal and flow conditions. The model is solved by the control volume procedure, which has been extended in order to take into account the 3D flow of liquid and ...
Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.
Results of researches on nitriding process of EJ961 steel are presented in this work. This steel was subjected to nitriding both on the cathode and on the isolated from cathode and anode substrate, that is at so called potential of glow discharged plasma. Nitriding processes were performed using device for glow discharge treatments with cooled anode. (author)
Craters were produced in the surface of a Pt-specimen by plasma discharge. Using a Focussed Ion Beam (FIB), TEM-foils of the cross section of the craters were prepared in order to examine the microstructural changes occurring as a result of the discharge impact. The molten material pushed to the edge of the craters was able to be identified. The grains beneath the craters reached the surface of the crater by a mechanism of epitaxial growth. (orig.)
The developed countries are implementing a policy minimizing damage from environmental pollution by reducing discharge in advance as well as the aftermath of a pollutant. The typical example is to use BAT (Best Available Technology). This is to prevent environmental damage by reducing the discharge of pollutants with available technology and to secure environmental margin to enable industrial activities of future generation. Therefore, the feasibility of introducing BAT requirement system was reviewed by considering foreign examples and Korean situation. 38 refs., 8 figs., 69 tabs.
A simple model is described to simulate kinetic processes in dielectric barrier discharges for O_2/NO_x mixtures. A threshold of ozone production found experimentally is confirmed by the calculations of this modeling, and the underlying chemical reaction mechanisms are discussed. It is also found that the effects of diffusion processes in the period of the lifetime of O atoms are not important to micro-discharge channels with a large radius, i.e. larger than 150 #mu#m
Oxide superconducting thin films were irradiated with X-rays and ultra-violet (UV) light, and induced radiation effects on electrical and chemical properties were examined by transport measurement, X-ray diffraction analysis (XRD), diamagnetization measurement and X-ray photoemission spectroscopy (XPS). After irradiation for ErBa_2Cu_3O_x films with X-rays emitted from a Rh tube for 100 hours, superconductivity was remarkably damaged, destroying the zero-resistance state. The UV-light irradiation for Bi_2Sr_2CaCu_2O_x films was performed in He gas of about 500 Pa with a low pressure mercury lamp. The superconductivity was gradually degraded with the UV irradiation time up to 70 minutes. In both cases, adequate oxygen-annealing treatments restored superconductivity. The X-ray photoemission spectra showed that the mean Cu valence of the films was decreased approximately from +2 to +1 by the irradiation. From these results we can find that ...
Objectives~%~ To quantify the volatile organic compound (VOC) emissions arising from the composting of a range of municipal and~%~ industrial wastes.~%~~%~ To relate the VOC emissions to the material being processed and the process conditions.~%~~%~ To confirm the findings of the above activites by monitoring full-scale composting operations.~%~~%~ To develop predictive models of VOC emissions in relation to waste feedstock and process conditions.~%~~%~ To produce guidance for plant designers, operators a [continued...]DescriptionA recent study of three composting plants undertaken for the Environment Agency has confirmed earlier work suggesting that waste composting can be a source of volatile organic compound (VOC) emissions. However, these experiments were restricted to garden and kitchen waste composting schemes and it was not possible to measure the effect that the process conditions had on the VOC emissions. ...
Condensing two-phase channel flow occurs in many industrial applications, including heating and refrigeration systems. It can also occur in certain nuclear reactor accidents. For example, during a small-break loss-of-coolant accident in a pressurized water reactor, following the partial depletion of the primary coolant, condensation of steam on the primary side of the steam generator tubes can provide a heat sink for disposal of the decay heat generated in the reactor core. Condensing two-phase flow can also play an important role in the operation of the passive emergency cooling system in the advanced simplified boiling water reactor. Here, steady-state condensation in the presence of a noncondensable in a concurrent two-phase channel flow is analyzed using a two-fluid model. The effect of noncondensables on the combined heat transfer at the liquid-gas mixture interphase is accounted for by using the stagnant film model, and closure relations ...
An overall plant design was developed for a gas-cooled fast reactor employing a direct supercritical Brayton power conversion system. The most important findings were that (1) the concept could be capital-cost competitive, but startup fuel cycle costs are penalized by the low core power density, specified in large part to satisfy the goal of significant post-accident passive natural convection cooling; (2) active decay heat removal is preferable as the first line of defense, with passive performance in a backup role; (3) an innovative tube-in-duct fuel assembly, vented to the primary coolant, appears to be practicable; and (4) use of the S-Co2 GFR to support hydrogen production is a synergistic application, since sufficient energy can be recuperated from the product H2 and 02 to allow the electrolysis cell to run 250 C hotter than the reactor coolant, and the water boilers can be used for reactor decay heat removal. Increasing core power ...
The performance of the new combustor was tested. Experiments showed that this combustor has superior insulating quality than the previous one. Measured radial concentrations indicated uniform distribution of the primary fuel (coal) inside the fire tube resulting in reasonably flat concentration profiles. However, measured radial concentrations after the addition of the reburn fuel showed uneven distribution of the fuel resulting in parabolic concentration profiles, an indication of insufficient mixing in the reburn zone. In order to study mechanisms of nitrogenous species destruction in the reburn zone, it is necessary to achieve adequate mixing if the assumption of one dimensional plug flow behavior is to be valid. Thus, it became necessary to modify the injector design and the injection mode of the reburn fuel to achieve an adequate level of mixing which is the focus of this report. The results show that a minimum reburn fuel jet velocity of 15 m/s (standard ...
Currently, high temperature filter systems are in the demonstration phase with the first commercial scale hot filter systems being installed on integrated gasification combined cycle (IGCC) and pressurized fluid bed combustion cycle (PBFC) systems (70 MW). They are dependent on the development of durable and economic high temperature filter systems. These filters are mostly ceramic tubes or candles. Ceramic filter durability has not been high. Failure is usually attributed to mechanical or thermal shock: they can also undergo significant changes due to service conditions. The overall objective of this project is to commercialize weldable, crack resistant filters which will provide several years service in advanced power processes. The specific objectives of this project are to develop corrosion resistant alloys and manufacturing processes to make Iron Aluminide filter media, and to use a ``short term`` exposure apparatus supported by other tests to identify the ...
Combustion of extremely fuel-rich ({phi}=4) methane/air mixtures at elevated pressures is investigated as a potential means to generate molecular hydrogen by non-catalytic partial oxidation. This system is investigated both computationally and experimentally. The computations use a perfectly-stirred reactor model and an explicit methane cool-flame mechanism to investigate the effects of reactor parameters on reaction time and product composition. Under adiabatic conditions, such mixtures are predicted to autoignite at low temperatures {approx}700 K for pressures exceeding 8.5 atm. Above 15 atm, conversion to products is complete in roughly 1 s. The dependence of reaction time and hydrogen yield is investigated as a function of inlet temperature, system pressure, and flame equivalence ratio. Actual product yields are measured in a tube reactor facility, and many of the predictions of the model, including long relaxation times to chemical equilibrium and temperatures ...
As for No.2 plant in Sendai Nuclear Power Station, which is the fourth nuclear power generation facilities in Kyushu Electric Power Co., Inc., all works have been completed, and at present, the final trial operation is under way. In No.2 plant, many new techniques for raising the reliability and safety, improving the maintainability and reducing radiation exposure were introduced on the basis of the operation experience of PWRs obtained so far, similarly to No.1 plant. In this paper, the main items of the new techniques related to the design and construction of the plant are reported. No. 2 plant is a first improved and standardized plant having the thermal output of 2660 MW for standard three-loop PWRs, and the rated power output was set at 890 MW. As for the turbine, TC6F-40 in was adopted. As the improved design, a large reactor containment vessel, 17 x 17 type 9-grid fuel, improved steam generators, a reactor vessel cover of one-body type, a titanium tube ...
Local properties and heat transfer have been investigated in a NaK-nitrogen two-phase flow in a vertical tube under transverse magnetic field. An objective two-phase flow regime identification was also carried out systematically, using the probability distribution function of two-phase electromagnetic flowmeter signals. The application of a magnetic field was bound to bring about a drastic change in the void fraction profile, i.e., asymmetric profile perpendicular to the field direction. This effect was more remarkably observed in bubbly flows. The magnetic field was also observed to decrease the number of bubbles, by promoting the agglomeration of small bubbles into larger ones and also break-up of large slugs, and, thus, to shift the flow regime boundaries. It has been also shown that the two-phase Nusselt number increases in bubbly flows, while it decreases in slug flows. This trend however reduces in the presence of a magnetic field.
Monitoring brine chemistry to determine the extent of potential adverse reactions was simplified by the development of a field brine test kit and a series of nomographs. Results of the kit analyses serve as input to the nomographs, which provide a graphic means of determining the scaling tendency (Saturation Index value) of a brine. Brines that do not tend to form scale may be corrosive. Saturation Index values have been correlated with various processes using data from geopressured wells in the Gulf Coast area. Control of scale in surface equipment of geopressured wells by chemical inhibitors has been successful. Downhole treatment with inhibitors to prevent scale formation in the production tubing is being investigated. Laboratory simulations indicate that an inhibitor squeeze treatment may be successful at the Gladys McCall No. 1 well. Inhibitor mixtures exhibit additive behavior at minimum concentration levels; however, behavior at maximum concentration may ...
This paper contains literature from American Power Conference Air Toxics Being Measured Accurately, Controlled Effectively NO{sub x} and SO{sub 2} Emissions Reduced; Surface Condensers Improve Heat Rate; Usable Fuel from Municipal Solid Waste; Cofiring Technology Reduces Gas Turbine Emissions; Trainable, Rugged Microsensor Identifies of Gases; High-Tc Superconductors Fabricated; High-Temperature Superconducting Current Leads; Vitrification of Low-Level Radioactive and Mixed Wastes; Characterization, Demolition, and Disposal of Contaminated Structures; On-Line Plant Diagnostics and Management; Sulfide Ceramic Materials for Improved Batteries; Flywheel Provides Efficient Energy Storage; Battery Systems for Electric Vehicles; Polymer-Electrolyte Fuel Cells for Transportation; Solid-Oxide Fuel Cells for Transportation; Surface Acoustic Wave Sensor Monitors Emissions in Real-Time; Advance Alternative-Fueled Automotive Technologies; Thermal & Mechanical Process; ...
A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization.
The WWR-SM reactor at the Institute of Nuclear Physics of the Academy of Sciences (INP AS) in Uzbekistan was converted to 6-tube IRT-4M LEU (19.7%) fuel in 2009. Presently, INP intends to also use IRT-4M 8-tube FA, and a safety analysis for these 'mixed' (8-tube and 6-tube FA) cores is required by the regulatory authorities. This paper presents results of control rod ejection transient analysis for these mixed cores
This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)
Using infra-red (IR) thermography, power loads onto the MKII Gas-Box divertor targets have been investigated in Type-I ELMy H-Mode plasmas at JET in medium current discharges (Ip = 2.6 MA and BT = 2.7 T). Heat fluxes are calculated from the measured divertor target tile surface temperatures taking into account the influence of co-deposited surface layers on tile surfaces. This is particularly important when estimating the energy deposition during transient events such as ELMs. Detailed energy balance analysis is used, both from IR and tile embedded thermocouples, to demonstrate an approximately constant ELM-averaged in/out divertor target asymmetry of ?0.55 and to show that the ELM in/out energy deposition ratio ranges from 1 : 1 to 2 : 1. The inter-ELM in/out ratio is close to the ELM-averaged value at low pedestal collisionalities and decreases down to values close to zero when the inner target plasma detaches at the highest pedestal ...
Total river discharge in Pakistan in summer season vary from 3 thousand to 34 thousand cusses (100 thousand Cusses to 1,200 thousand Cusses) and can cause tremendous loss to human lives, crops and property, this causes the loss of most of the flood water in the lower Indus plains to the sea. Due to limited capacity of storage at Tarbela and Mangla Dams on river Indus and Jhelum, with virtually no control on Chenab, Ravi and Sutlej, devastating problems are faced between July and October in the event of excessive rainfall in the catchments. Due to enormous amounts of sediments brought in by the feeding rivers, the three major reservoirs -Tarbela, Mangla and Chashma will lose their storage capacity, by 25 % by the end of the year 2010, which will further aggravate the water-availability situation in Pakistan. The quality of water is also deteriorating due to urbanization and industrialization and agricultural developments. On the Environmental Front the main problems ...
The opportunity of use self-maintained plasma-beam discharge in an extended pulsing plasma diode of low pressure for making powerful sources of the soft X-rays is investigated. Conditions of formation of the self-maintained plasma-beam discharge are determined. The mode of making of dense high-temperature plasma on the basis of stannum ions in the discharge is shown. The stannum ions are used as a working element of a radiation sources at pulsing power of electron beam P?10...100 MW. Results of the examination on formation of the dense (np?1016 cm3), small sizes (le?100 eV in conditions of working material evaporation from the anode are given. The total contribution of energy to the discharge has made W < 20 J.
In this paper we study theoretically a pulsed corona discharge plasma in air at atmospheric pressure. A self consistent one-dimensional model, using a flux-corrected transport numerical scheme, is presented to achieve it. The charged particle kinetics in this model are described by one-dimensional continuity equations coupled with Poisson's equations. The spatio-temporal local field, charge density variations and the velocity profile of an ionizing front are calculated to describe the dynamical behavior of corona discharge plasmas. The simulation results of a wire-in-cylinder corona discharge plasma explain the physical mechanisms of discharge processes. These results may also be apply to obtain the optimizing parameters for designing the plasma reactor.
This engineering report compiles information on types and quantities of liquid waste discharged from B-Plant directly to cribs, ditches, reverse wells, etc., that are associated with B-Plant. Waste discharges to these cribs via overflow form 241-B, 241-BX, and 241-BY tank farms, and waste discharged to these cribs from sources other than B-Plant are discussed.Discharges from B-Plant to other cribs, unplanned releases, or waste remaining in tanks are not included in the report. Waste stream composition information is used to predict quantities of individual chemicals sent to cribs. This provides an accurate mass balance of waste streams from B-Plant to these cribs. These predictions are compared with known crib inventories as a verification of the process.
New non-stationary non-contracted form of the erosive radially-slotted discharge as a thin round sheet with the current of the azimuth direction have been discovered, its existence beings stipulated by a radial transport-wave fluxes. Characteristic features of this discharge is self-confinement of the discharge current magnitude, corresponding decrease of the current pulse duration and occurrence of an energy and substance ejection with rather unusual properties. Measurements of kinetics of the discharge current, the plasma radiation intensity and an electrical probe signal, as well as the transmission electron microscope investigations of characteristic aerodisperse aggregates arising the erosive phase, have been carried out. The probe signal duration was about 10 times greater than that of the current; its kinetics was complicated suggesting existence in the slot of two components with fundamentally ...
With appropriate circuit resistance and inductance and sufficient stored energy, discharging a charged human body or component through an exploding bridgewire (EBW) detonator may cause the detonator to function or may damage the detonator. We have studied the effects of electrostatic discharge (ESD) on a number of exploding bridgewire detonators which were subjected to discharges which passed directly through the bridgewires (pin-to-pin), as well as discharges which passed from the bridge to the metal case of the detonator (pin-to-case). We have performed calculations to determine the values of inductance and resistance for which burst and melt may occur for given ESD sources, using a phenomenological model of bridgewire burst in a computer code called FIRESET. Bridge melt was computed using the same computer code, but using experimental values of bridge resistivity and specific heat up to melt. 13 ...
This report summarizes the research conducted during Budget Period One on the project ''Improved Natural Gas Storage Well Remediation''. The project team consisted of Furness-Newburge, Inc., the technology developer; TechSavants, Inc., the technology validator; and Nicor Technologies, Inc., the technology user. The overall objectives for the project were: (1) To develop, fabricate and test prototype laboratory devices using sonication and underwater plasma to remove scale from natural gas storage well piping and perforations; (2) To modify the laboratory devices into units capable of being used downhole; (3) To test the capability of the downhole units to remove scale in an observation well at a natural gas storage field; (4) To modify (if necessary) and field harden the units and then test the units in two pressurized injection/withdrawal gas storage wells; and (5) ...
Ocean thermal energy conversion (OTEC) plants discharge large volumes of cold water into the upper ocean. A three-dimensional, limited-area model was developed to investigate the regional influence of the far-field effluent plume created by the negatively buoyant discharge. The model was applied to discharges from a 40-MW/sub e/ OTEC plant into coastal waters characterized by various ambient ocean conditions. A typical ambient temperature structure and nutrient distribution, as well as the behavior of the effluent plume itself, were strongly modified by the discharge-induced circulation. Although temperature perturbations in the plume were small, upward entrainment of nutrients from below the thermocline was significant. The regional influence of discharges from an 80-MW/sub e/ OTEC plant, the interactions between the discharges from two adjacent 40-MW/sub e/ ...
Electron trapping in crossed electric and magnetic fields is an important mechanism by which electrical discharges can develop in low pressure gases. The authors report observations of discharges produced by this mechanism around a spherical anode in two space simulation chambers, namely the Space Plasma Interaction Experiment (SPIE) at the University of Maryland, and the NASA-Lewis B-2 chamber. They have identified two types of discharges in these experiments. In the B-2 chamber, the breakdown takes the form of a runaway dischage with spherical topology, limited only by the ability of the power supply to provide the current. In the SPIE chamber this type of discharge also occurs, in addition to a low current toroidal discharge which is observed at higher magnetic fields. They present measurements of both types of discharge and show how the trapping effect of ...
'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. ...
'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. These indications ...
It is one of the most important subjects to estimate the flow-related stability of the heat exchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected ...
In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse flow agrees very well ...
The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).
In order to improve the reliability of PWR steam generators, we have performed research to improve the tubing material and tube-support-plate configuration, based on our wide operating experience, and have developed and verified Alloy TT690 as the optimum tubing material and the BEC (Broached Egg Crate) type tube-support design. In the research, we have studied the metallurgical mechanism of the alloy to improve its corrosion resistance, evaluated corrosion susceptible region quantitatively, estimated the actual environment in a steam generator and confirmed the reliability by a model boiler test over a long period. It has been verified that the steam generator with the latest design has higher reliability with respect to the corrosion resistance of tubes. (author).
In the course of designing a catalytic porous membrane reactor for experimental studies, both inside and outside of the non-reaction zones as well as the two ends of the membrane need to be completely sealed to ensure that there is no flow across the membrane in the non-reaction zone. Experiments show that up to 50% of the total flow across the membrane may be contributed by the axial flow along the wall of the non-reaction zones if only one side of the membrane is sealed. Another problem that cannot be solved by sealing is the capillary flow of the catalyst along the tube wall into the non-reaction zones when the catalyst is doped on the membrane. One of the best ways to avoid this axial flow of catalyst would be to use non-porous tubes in the non-reaction zones and join them with the porous membrane tube. In doing so, the cost of the membrane reactor could be reduced simply because shorter membrane ...
In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. The difficulties associated with the simulation of a heat exchanger augmented with ...
Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.
Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.
Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.
Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.
VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas...Full Text Available
...A directory of University social media accounts, including Facebook, Twitter and YouTube facebook, twitter, blog Social media - Social media, The ... Key: Facebook, Twitter, YouTube, Blog, LinkedIn, Flickr Missed you out? If you'd like to be included on this ...
BackgroundPercutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal...Full Text Available
Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. ...
Congenital deformities involving the coverings of the nervous system are called neural tube defects (NTDs). NTD can be classified as neurulation defects, which occur by stage 12, and postneurulation...Full Text Available
BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available
The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core manufacturing process ...
Faulting the feedwater for a 19-tube, model steam generator with 10 ppM of caustic once a week produced widespread shallow 25 to 75 micrometers (1 to 3 mils) intergranular attack (IGA) on alloy 600 tubes and an axial tube rupture at the steam-water interface after 4.8 years. An extensive investigation of the IGA damage found little correlation with major test variables beyond the indication that mill-annealed tubing was more susceptible to attack than stress-relieved tubing. The most likely cause of the tube rupture was caustic that concentrated to high levels in a porous scale on the tube at the liquid-vapor interface where there was a high available superheat. Nondestructive examination (NDE) eddy current probes underestimated the depth of IGA and were not sensitive to circumferential cracks less than 152 micrometers (6 mils) deep that ...
Statistical data on experience gained from operation of steam generators around the world are presented, problems arising in vertical and horizontal steam generators are described, and the conditions of heattransfer tubes used in them are compared.
The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between ...
Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in ...
An inner surface substrate of metal tubes is provided with a single layer of randomly distributed metal bodies bonded to the substrate, spaced from each other, and substantially surrounded by the substrate to form body void space.
Esophageal perforation is associated with a significant risk of morbidity and mortality. We report herein a case of lye-induced esophageal perforation managed successfully by employing endoscopic T-tube...Full Text Available
Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the ...
Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were ...
BackgroundTraumatic pneumothoraces are common. Many are managed with tube thoracostomy. However, there is a high complication rate from chest tube placement, particularly in patients...Full Text Available
We present the results obtained from tests and studies carried out on the model of tube bundles for a PGV-1000 horizontal steam generator that were conducted for experimentally substantiating the design service life of a steam generator tube bundle intended for use at new nuclear power stations equipped with a PGV-1000MKP steam generator. Measures taken to minimize the incipience and development of local corrosion damage to the heat-transfer tubes and ensure their design service life are substantiated and confirmed.
In PWR steam-generators, the crevice between tube and tube-support plate tends to fill with porous deposits during operation and acts as a concentration site for chemicals in the boiler water, which may lead to corrosion of the tube and tube-support-plate. The rate of concentration, the magnitude of the concentration factor and the rate of release of solute when conditions change are important parameters for devising strategies to minimize corrosion. Values of these parameters for salt concentration have therefore been measured in a laboratory simulation of the crevice and are used to formulate a model of the concentrating process.
The shot peening of the outer surface of Alloy 800 is proposed by the steam generator supplier in order to increase the stress corrosion cracking resistance of the tubes. The benefits and drawbacks of such a treatment are evaluated, focusing on the main concern i.e. a possible enhanced tendency of stress corrosion cracking at the transition of the expanded tube-to-tubesheet joint. Stress corrosion tests as well as residual stresses measurements demonstrate no significant difference between peened and unpeened tubes at that location. The other concerns such as stability of the compressive stresses, increased risk of pitting or intergranular attack and pollution of the secondary circuit by fragmented beads appear the as minor concerns.
Tube failures due to excessive flow-induced vibration must be avoided to assure the reliable performance of heat exchangers. Such components must be thoroughly analysed for vibration at the design stage. Several flow-induced vibration mechanisms are possible. In this paper, particular attention is given to fluidelastic instability of tube bundles subjected to liquid and two-phase cross-flow. The performance of ten operating heat exchanger components is reviewed to validate our recommended vibration analysis guidelines. Both tube failure histories and satisfactory performances are considered. The results show that a fluidelastic instability constant K=3.3 is a reasonable design criterion. (auth).
sabot: A device fitted around or in back of a projectile in a gun barrel or launching tube to support or protect the projectile or to prevent the escape of ...
A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)
In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.
Polymers are required to use in radiation environments as insulation materials. However, they often suffer from tracking failure. There is an increasing demand to evaluate radiation effects on dielectric performance. This paper presents a recurrence plot (RP) approach to analyse surface discharge sequences of gamma-ray irradiated polymer materials based on tracking test. Studying the non-linear characteristics of discharge sequences can assist in understanding the underlying mechanism of the discharge process. Discharge sequences of the test are extended to m-dimensional phase space by using the phase space reconstructed method. As test samples, polybutylene terephthalate (PBT) and polybutylene naphthalate (PBN) were irradiated to 100 kGy and then up to 1 MGy with a dosage rate of 10 kGy h{sup -1} by using a {sup 60}Co gamma source. The tracking tests were carried out according to the test method ...
This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heat exchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).
A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).
In this work, the thermal performance of a conventional collector is improved by inserting porous substrates at the inner walls of the collector tubes. The porous substrates improve the convective heat transfer coefficient between the tube wall and the fluid. This improvement is investigated numerically and its effects on the efficiency and the useful gain of the collector are evaluated. It is found that inserting the porous substrate may raise the collector efficiency considerably, especially at high values of the overall heat loss coefficient.
The patent concerns pipe crawlers, i.e. apparatus capable of moving along the bores of pipes and tubes. Pipe crawlers are employed for conveying inspection equipment along the bores of pipes and tubes. The pipe crawler comprises a piston and assembly system, which controls the movement of the crawler and supports the assembly centrally within the bore of the pipe or tube. (UK).
When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...
When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...
The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions.
In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.
In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.
A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.
This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in ...
The invention relates to a method for purifying a gas mixture containing at least one undesirable gas compound utilizing certain sulfonamide or sulfamide solvents.
The gel electrolyte for the zinc-air cell was prepared by mixing hydroponics gel with a 6M potassium hydroxide aqueous solution. The self-discharge of cells was characterized by measuring the open-circuit voltage. The effect of a discharge rate of 50mA constant current on cell voltage and plateau hour, as well as the voltage-current and current density-power density were measured and analysed. The electrode degradation after discharge cycling was characterized by structural and surface methods. The oxidation of the electrode surface further blocked the utilization of the Zn anode and was identified as a cause for the failure of the cell. (author)
Oxidation of propylene with oxygen, air and a mixture of nitrogen?oxygen in a barrier discharge is investigated. The selectivity towards formation of propylene oxide in pure oxygen is shown to be as high as 45 wt% and the propylene conversion ratio is found to be 12.9 wt%. In the oxidation with air, the propylene oxide selectivity is 23 wt%, while the conversion is 7.5 wt%. The values of propylene conversion and selectivity towards formation of propylene oxide in a barrier discharge are consistent with those obtained by the thermocatalytic methods for production of propylene oxide.
This patent describes an ignition system of an internal combustion engine which consists of: a permanent magnet supported by a rotary member of the engine adapted to rotate in synchronism with a rotary shaft of the engine; a generating coil for generating an electromotive force to produce an electric current as the permanent magnet acts on the generating coil during the rotation of the rotary member; an ignition capacitor charged by the electric current generated by the generating coil; a thyristor caused to turn on by a counter electromotive force generated by the generating coil to thereby cause the ignition capacitor to begin to discharge; and an ignition coil generating a high voltage as the ignition capacitor begins to discharge, to cause a spark discharge to take place in an ignition plug of the internal combustion engine.
Glow discharge plasma nitriding of AISI 304 austenitic stainless steel has been carried out for different processing time under optimum discharge conditions established by spectroscopic analysis. The treated samples were analysed by X-ray diffraction (XRD) to explore the changes induced in the crystallographic structure. The XRD pattern confirmed the formation of an expanded austenite phase (#gamma#_N) owing to incorporation of nitrogen as an interstitial solid solution in the iron lattice. A Vickers microhardness tester was used to evaluate the surface hardness as a function of indentation depth (#mu#m). The results showed clear evidence of surface changes with substantial increase in surface hardness.
In this work a flat receiver of self construction is shown with relatively low cost and easy manufacture, but with a thermal efficiency superior to 40% for applications at temperatures less than 60 degrees Celsius, that allows satisfying international standards in this respect. The heater has been matter of study in open courses distributed in the Universidad Autonoma de la Ciudad de Mexico (UACM) oriented to that the participants construct their own system, in addition to its installation and tests. The obtained results have been excellent. The massive use of efficient solar receivers of self-construction can truly help to the decreasing of the gasdischarges of greenhouse effect. [Spanish] En este trabajo se presenta un captador plano de auto construccion con relativamente bajo costo y facil manufactura, pero con un rendimiento termico superior a 40% para aplicaciones a temperatura menos de 60 grados centigrados que le permite satisfacer ...
Among the most promising technological alternatives for the development of photovoltaic modules and cells of a low cost, good energetic conversion and feasibility for mass production, polycrystalline silicon thin film solar cells deposited directly on a transparent substrate are currently being considered the best. We have developed in our laboratory a PECVD reactor capable of producing the deposition of amorphous hydrogenated silicon at rates of above 2 nm/seg, allowing a significant production per line on the plant. Dischargegas is silane, to which diborane or phosphine is added so as to form the cell. Basically, work is done on a structure of cell type TCO/n+/p-/p+/M, which has 2 {mu}m of total thickness. Schott AF-37 glass is used as a substrate, for their ability to withstand temperatures of up to 800 C. The amorphous cell is subsequently annealed at gradual temperatures of 100 C to achieve dehydrogenation up to 650-700 C for 12 h until ...
High quality single-walled carbon nanotubes (SWNT) have been synthesized at large scales by the method of direct evaporation of carbon black and metallic catalyst mixtures, using induction thermal plasma technology. The processing system consists mainly of an RF plasma torch, which generates a plasma jet of extremely high temperature (?15 000 K), with a high energy density and abundance of reactive species (ions and neutrals). With the present reactor system, it has been demonstrated that carbon soot product which contains approximately 40 wt% of SWNT can be continuously synthesized at the high production rate of ?100 g h-1. The processing parameters involved have been examined closely in order to evaluate their individual influences on SWNT synthesis. The results have shown that the quality and purity of the SWNT produced are critically affected by the grade of carbon black, the plasma gas composition and the metallic catalyst employed. Theoretical calculations, ...
The liquefaction reaction system of an NEDOL process coal liquefaction 1t/d PSU was opened and checked to investigate the cause of the rise of differential pressure between liquefaction reactors of the PSU. The liquefaction test at a coal concentration of 50 wt% using Tanito Harum coal was conducted, and it was found that the differential pressure between reactors was on the increase. By the two-phase flow pressure loss method, deposition thickness of deposit in pipelines was estimated at 4.4mm at the time of end operation, which agreed with a measuring value obtained from a {gamma} ray. The rise of differential pressure was caused by deposit formation in pipelines connecting reactors. The main component of the deposit is calcite (CaCO3 60-70%) and is the same as the usual one. It is also the same type as the deposit on the reactor wall. Ca in coal ash is concerned with this. To withdraw solid matters deposited in the reactor, there are installed pipelines for the withdrawal at the ...
In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle vs. mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements in compressible flows. This paper presents results of steady compressible flow testing of an NPS 4 swing type check valve in air. Mean flow velocities vs. disc angles were measured together with several local pressure measurements at the ...
Some magnetron sputtering systems experience rapid oscillations in the current and voltage of the plasma discharge after several hours when equipped with certain targets. These oscillations often lead to the plasma becoming extinguished, a condition known as ''flame-out.'' This article details the study of two 90% W--10% Ti magnetron targets which differed in density. The higher density targets sometimes experienced flame-out after approximately 3 h of sputtering. The less dense material could be sputtered for the entire 15 h life of the target. Scanning electron microscopy pictures and atomic composition depth profiles were obtained using Auger electron spectroscopy. In addition, a Colutron-based ion source with a high vacuum system was used to measure ion-induced secondary electron emission coefficients as a function of energy, ion specie, and gas coverage. Analysis of the sample from the group that suffers flame-out showed large regions of ...
In the design of natural gas compressor stations, a check valve is a critical element which is commonly placed on the discharge side of the compressor to prevent reverse flow that can cause serious damage to the compressor itself and other components such as seals and bearings. One of the selection criteria of the check valve for this particular application is the valve flow characteristics in steady flow, and its dynamic characteristics in unsteady flow operation. With regards to steady flow valve characteristics, current models for the determination of the check valve open angle versus mean flow velocity are based on semi-empirical data obtained from water tests, which were found to deviate from measurements involving fluids of relatively higher compressibility. This paper presents results of steady flow testing of an NPS 4 swing-type check valve in air. Mean flow velocities versus disk angles were measured together with several local ...
The potential for detoxification and deodorization of sulfide-laden water (sour water) by microbial treatment was evaluated at a petroleum production site under field conditions. A sulfide-tolerant strain of the chemautotroph and facultative anaerobe, Thiobacillus denitrificans, was introduced into an oil-skimming pit of the Amoco Production Company LACT 10 Unit of the Salt Creek Field, Wyoming. Field-produced water enters this pit from the oil/water separation treatment train at an average flowrate of 5,000 bbl/D (795 m{sup 3}/D) with a potential maximum of 98,000 bbl/D (15,580 m{sup 3}/D). Water conditions at the pit inlet are 4,800 mg/l TDS, 100 mg/l sulfide, pH 7.8, and 107{degrees}F. To this water an aqueous solution of ammonium nitrate and diphosphorous pentoxide was added to provide required nutrients for the bacteria. The first 20% of the pit was aerated to a maximum depth of 5 ft (1.5 m) to facilitate the aerobic oxidation of sulfide. No provisions for pH control or biomass ...
TOXCHEM is a microcomputer based modelling system for predicting the fate of toxic contaminants in wastewater treatment plants. The package evaluates concentrations of toxics in final effluent and waste sludge, and mass air emissions from municipal or industrial activated sludge wastewater treatment plants. Maximum allowable influent concentrations of toxics required to meet effluent discharge or air emission limits can also be estimated. The package contains a read-only database with treatability parameters for over 100 contaminants, including organic compounds and metals. If effluent or sludge quality limits have been specified, treatment plant owners and operators can use the package to estimate the permissable discharge limits for dischargers to their collection system. A hypothetical example is provided of application of the software to a planning problem involving the start up of a new operation that would ...
Objectives: To evaluate the training of pharmacists in Accra, Ghana, in the syndromic management of STIs. Methods: We randomly selected 50 pharmacy outlets that had...Full Text Available
Provisions (a) NPDES field personnel shall be currently trained and certified in CPR and basic first-aid procedures. (b) NPDES field personnel shall be aware of the...
... explosive (shotgun shells, etc.) method of forming is being replaced--for the most part--by the electri- cal discharge and magnetic forming methods. ...
At atmospheric pressure and room temperature, dielectric barrier discharge induced plasma oxidation for achieving supported TiO2 photocatalysts derived from TiCl4 adsorbed onto ?-Al2O3 pellets was studied. The supported TiO2/?-Al2O3photocatalysts prepared by a cyclic 'adsorption-discharge' approach, without requirement of heat treatment, exhibit high activity in the photocatalytic degradation reaction of formaldehyde. The mass spectra and optical emission spectra during O2/Ar discharge for oxidizing the adsorbed-state TiCl4 were measured. The mechanism for the TiO2 formation from adsorbed-state TiCl4 by plasma oxidation was discussed.
The ozone production process in a pulsed positive dielectric barrier discharge (DBD) is studied by measuring the spatial distribution of ozone density using a two-dimensional laser absorption method. DBD occurs in a 6 mm point-to-plane gap with a 1 mm-thick glass plate placed on the plane electrode. First, the propagation of DBD is observed using a short-gated ICCD camera. It is shown that DBD develops in three phases: primary streamer, secondary streamer and surface discharge phases. Next, the spatial distribution of ozone density is measured. It is shown that ozone is mostly produced in the secondary streamer and surface discharge, while only a small amount of ozone is produced in the primary streamer. The rate coefficient of the ozone production reaction, O + O_2 + M #-># O_3 + M, is estimated to be 2.5 x 10"-"3"4 cm"6 s"-"1.
By Charles E. Watkins. 2458. An Instrument Employing a Coronal Discharge for ..... Grover, W. S. Hyler, and L. R. Jackson. 2640. Interaction of Column and ...
This progress report consists of an article, the abstract of which follows, and apparently the references and vita from a proposal. A review of perturbation diagnostics applied to microwave resonant cavity discharges is presented. The classical microwave perturbation technique examines the shift in the resonant frequency and cavity quality factor of the resonant cavity caused by low electron density discharges. However, modifications presented here allow the analysis to be applied to discharges with electron densities beyond the limit predicted by perturbation theory. An {open_quote}exact{close_quote} perturbation analysis is presented which models the discharge as a separate dielectric, thereby removing the restrictions on electron density imposed by the classical technique. The {open_quote}exact{close_quote} method also uses measurements of the shifts in the resonant conditions of the cavity. Thirdly, ...
The tide field at the time of liquid effluent discharging from Daya Bay nuclear power station, and the average water speed at the monitoring points in west Daya Bay from the time of discharging to the time of sampling were calculated by ADI (Alternating Direction Implicit) method. By comparing analysis, the difference of "3H diffusion between spring tide and neap tide (the expansion of "3H within one day of spring tide is greater than that within one day of neap tide) was found. So, an equivalent diffusion time is introduced to modify the original model, and a better attenuation relation between the average "3He concentration in west Daya Bay and the time since the liquid "3H discharging is obtained. (authors)
Plasma Technologies in Institute of Plasma Physics of the NSC KIPT are recently developed in the following directions. Material surfaces modification under their irradiation with pulsed plasma streams of different working gases. Besides traditional analysis of improvements of tribological characteristics and structural-phase changes of the modified layers recently we started investigations of material corrosions characteristic improvement under influence of pulsed plasma on the material surfaces. As to the surface coatings in arc discharges of Bulat type devices, new trends are related with multi-layers coatings, using Ti-AI-N coatings in cutting tools, using high frequency discharges or combined HF- and arc discharges for increasing the nomenclature of goods to be coated. Development of ozonators is respectively new area for IPP NSC KIPT. On the base of barrier high-frequency discharge there were ...
The buckling behaviors of double-walled carbon nanotubes (DWCNTs) under torsion are investigated by using molecular dynamics (MD) simulations. The effect of length on the torsional buckling behaviors of DWCNTs is examined for the first time. The simulation results show that the DWCNTs experience gradual or simultaneous buckling deformations depending on their lengths. In addition, the effect of the inner tube in a DWCNT on its torsional buckling behavior is also examined. The presence of the inner tube triggers van der Waals (vdW) interactions between it and the outer tube and thus leads to a stiffening effect of the DWCNT against torsional deformation. Whether the ends of the inner tube are free or fixed and whether it is subject to a torque or not, the critical torque and the critical torsional angle of the outer tube are only marginally affected.
Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...
Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...
The Superphenix 750-MW (thermal), once-throughtype steam generators are the result of over 10 years of intensive research and development. Detailed design and manufacture of the components lasted from 1977 to 1982. The main difficulties encountered during the construction of these prototype units concerned: demonstration of satisfactory high-temperature properties of Alloy 800 tubes; proven resistance of tube welds to thermal fatigue and of structures and shells to sodium/ water reaction effects; prevention of the tube bundle to flow-induced vibration; necessity of manual welding of shells to prevent hot cracking hazards related to the boron content of the steel; and welding of heat exchange tubes. None of these difficulties, however, invalidated initial major design choices, but provided a wealth of technical and technological experience and knowledge for the steam generators of the future. Plans for ...
Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)
Denting phenomenon as experienced in PWR steam generators has been investigated in the laboratory of Monel-400 tubes and C-steel baffles combination. Isothermal corrosion tests have been carried out by exposing capsules, containing a crevice between Monel-400 tubes and C-steel plugs, in plausible corrodents at 300"0C. Results indicated that the denting phenomenon is strongly influenced by the chloride content in the solution. In addition, it is a time dependent process. Stress exerted on the tubes by the growth of corrosion product on the outside surface of C-steel plugs are enough to deform the Monel tubes. The results have been discussed on the basis of accelerated corrosion of C-steel by hydrolyzable metal chlorides. (author).
Accumulation of Chloride and Cupric ions under the sludge on the steam generator tubing surface in the area between tube sheet and the first tube support is known to be the main reason for the pitting corrosion. In addition to those ions, oxygen, pH, temperature, heat treatment history, contests of minor elements such as C, S or Ti in the alloy are also influencing the material's the pitting corrosion resistance. a series of autoclave pitting test was conducted to evaluate the pitting corrosion characteristics of the domestically produced alloy 690 tubing material and compare with that of INCO manufactured material. 16 refs., 44 figs., 5 tabs. (Author)
Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...
Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...
During the Bruce A Nuclear Generating Station (BNGS-A) Unit 1 1997 planned outage, a dew point search method identified a leak in one steam generator(SG) tube. Subsequently, the tube was inspected with all available eddy current probes and removed for examination. The initial inspection results and metallurgical examination of the removed tube confirmed that the leak was due to intergranular attack/stress corrosion cracking (IGA/SCC) emanating from the secondary side of the tube at the top of the tubesheet location. Subsequently, eddy current and ultrasonic indications were found at the top of the tubesheet of other Alloy 600 SG tubes. To investigate the source of the indications and to validate the inspection probes, sections of 40 tubes with various levels of damage were removed. The metallurgical examination of the removed sections showed that both secondary ...
Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...
Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...
Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant operation, steam generator ...
Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial mass, momentum and ...
Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. ...
Radian received twelve sections of heat exchanger tubing from the Magma Electric Company's 10MW(e) East Mesa binary geothermal power plant. Three tube sections were received from each of four shell and tube heat exchangers (HX1, Hx6, HX8, and Hx10) of the isobutane vaporizer train. All samples were taken from the upper few rows of tubes. Two months later, four more tube sections were received. These four sections were taken from the lower rows of heat exchangers 1, 6 (two sections), and 10. Radian was requested to investigate the cause of severe pitting failure of these heat exchanger tubes. This report is part of a continuing DOE effort to gain insight into the service life of component materials employed in geothermal energy utilization.
The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present ...
A publication on Norwegian gas and gas export. The content is wide spread from use of gas in daily life via sub sea pipeline repair systems to an overview over tomorrows gas fields. (AG)
Electron Cyclotron Heating experiments have been performed on the TEXT tokamak using Varian gyrotron. Some degradation of electron energy confinement is observed for sawtoothing and non-sawtoothing discharges. Sharp electron temperature profiles are produced in high-q discharges by extremely localized ECH power deposition.
The effect of atmospheric radioactive emissions from United Kingdom nuclear installations on acid deposition is assessed. Nitrogen oxide and ozone production resulting from and associated with discharges of airborne radioactivity, comparison with conventional emissions, and the direct effects of radioactive emissions on trees, are all discussed. (UK).
The experimental superconducting magnetic system of 0.5 MJ energy storage is described. The step variation of the winding inductance provides a control by the discharge current at the energy output on a high-ohmic load. The voltage on a load is 45 kV at the current 1100 A under the controllable discharge conditions. The energy transfer coefficient constitutes 0,76 under the maximum-to-minimal current ratio equal to 1.3. 7 refs., 3 figs., 2 tabs.
Solutions have been found for the problems encountered with the coil power and switching systems of the International Fusion Superconducting Magnet Test Facility (IFSMTF). The coil power system provides the filtered dc sources (+- 12 V dc; 25,000 A) for charging and discharging the coils of the IFSMTF experiment. The switching system provides the means of transferring the coil current into a dump resistor when a rapid discharge of a coil is required due to a coil failure (quench) or other system abnormalities.
Abstract An analytical model is developed to predict transient discharge flow into a tunnel drilled at various speeds through a heterogeneous formation. This model relies on simplifying assumptions commonly enforced in hydrogeologic engineering, and combines the convolution and superposition principles to account for composite sections with arbitrary parametric contrasts. An application to the data monitored during the exploratory drilling of an Alpine tunnel confirms the validity of the approach.
In this study, Cu{sub 2}O/Cu composite particles were synthesized using an innovative chemical reduction method without any template and surfactant. X-ray diffraction (XRD) analysis revealed that the product mainly consisted of Cu{sub 2}O phase coexisting with a Cu phase. FE-SEM images showed that the octahedral shaped particles were Cu{sub 2}O. The electrochemical performance of the Cu{sub 2}O/Cu particles was investigated with regards to the working electrode material in alkaline solution. The particles had a maximum discharge capacity of 222.9 mAh/g at a discharge current density of 60 mA/g and a high value of 109.1 mAh/g after 50 charge-discharge cycles. Cyclic voltammetry revealed that the reaction between Cu{sub 2}O and Cu is the major electrochemical reaction during the charging and discharging process. Electrochemical impedance spectroscopy revealed that the formation of Cu{sub 2}O on the ...
Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings suggestive of ...
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides ...
Full text of publication follows: Energy and environment are two major concerns in our modern society due to the coming shortage in fossil energy sources and the growing of greenhouse gas emissions. The challenge for the coming years is to discover new energy resources and to develop devices that are compatible with a sustainable development and generate few (or zero) emission. One of these devices is the fuel cell feed by hydrogen, whose application fields are very large. In particular, the proton exchange membrane fuel cell (PEMFC) is the most realistic device for automotive application. However, hydrogen storage remains one of the most important challenges regarding its development. Although different techniques are available for storing hydrogen, no ideal solution has been found yet. Compression needs elaborated tanks in shape for supporting high pressures, liquefaction requires an expensive hydrogen cooling and adapted tanks. Chemical storage by hydrides ...
Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...
Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...
Stream temperature is an important physical characteristic of headwater streams that plays a critical role in the presence and health of juvenile salmonids. Headwater stream temperature was documented in two geomorphic settings on the Kenai Peninsula, Alaska, focusing on the variation in temperature induced by diffuse groundwater discharge and variable air temperature. Eighteen headwater stream reaches were studied in four watersheds, with 11 drainageway sites and seven discharge-slope sites. In drainageway sites, low-gradient streams flow through broad valleys with groundwater-fed fen wetlands; in discharge-slope sites, high-gradient streams flow through narrow valleys with groundwater-fed slope wetlands. At all 18 sites, hourly stream temperatures were measured for one year. At one drainageway and one discharge-slope site, groundwater temperatures, stream stages, and groundwater heads in the local ...
Thermal models are constructed and analyses are performed of aluminum-based spent nuclear fuel (Al-SNF) in interim dry storage and geologic disposal configurations. Two models are developed, referred to as the interim storage model and the codisposal waste package (WP) model. Time-dependent source terms of Al-SNF forms and the defense high-level waste (DHLW) canisters are also developed for thermal performance analysis of the geologic codisposal WP.The interim storage model is a three-dimensional conduction-convection conjugate model to investigate the natural convection cooling of a sealed dry storage canister with vertical orientation in a dry storage vault. The analysis is made for various decay heat sources (equivalent to 25 to 35 kW/m{sup 3}) using various boundary conditions around the canister wall and with backfilled nitrogen or helium gas. Based on the data obtained from the Savannah River Site experimental work and available from the literature, an ...
This paper discusses the evolution of the horizontal subsea tree and its utilization in increasingly demanding applications. Initially, the Horizontal Tree was seen as a solution for wells requiring high well maintenance, such as those using electrical downhole pumps. Today, the horizontal tree is being applied to natural drive wells because of attractive whole life economics. This raises concern in a number of areas. Tubing hanger seals are permanently exposed to well fluids, and must provide high integrity sealing. This required the development of a new type of radially energized, all metal sealing system, specifically for horizontal tree applications, suitable for oil or gas service at working pressures to 15,000 psi. In addition, horizontal tree pressure integrity depends on the master valve stem, gate and bonnet seals. The need for high seal integrity also dictates that the first master valves should be integral to the main body of the ...
Source term release characteristics are analyzed for the severe SGTR (Steam Generator Tube Rupture) sequences beyond the design basis accidents in Wolsong 2/3/4 plants which are of CANDU6 type reactor. In PWRs, SGTR sequences have long been recognized to be important and are distinctly different from the non-bypass sequences since there is a direct fission product release path from the primary system to the environment bypassing the containment gas volume. Meanwhile, a SGTR in a CANDU reactor is analyzed not to provide a complete and direct path into the environment for the source term resulting from a severe accident. This is because the majority of the fission product released arises from heatup and interactions of the disassembled fuel channel segments and debris in the calandria tank rather than from fuel heatup in the fuel channel. These fission products are released from the calandria tank into the containment atmosphere through the four ...
The performance of two-cell planar solid oxide fuel cell stacks using coal syngas, with and without hydrogen sulfide (H{sub 2}S), was studied. All cells were tested at 850 C with a constant current load of 15.2 A (current density of 0.22 A cm{sup -2} per cell) and 30% fuel utilization. The H{sub 2}S injection immediately and significantly affected the power degradation of the stack system regardless of the carrier fuel. Results for the test with only H{sub 2} and N{sub 2} in the presence of H{sub 2}S (119-120 ppm) indicated that the power decay and area-specific resistance (ASR) degradation values were lower than those for the tests where simulated syngas containing CO and increased water content was used. The results indicate that contact points in the stack contributed to the power degradation of the system. Other factors, including contamination from the upstream fuel gastubing, may have contributed to the higher degradation under simulated ...
The current work continues a project completed in 1999 by ReMaxCo Technologies in which a novel, microwave based, VLS Silicon Carbide Fibrils concept was verified. This project continues the process development of a pilot scale commercial reactor. Success will lead to sufficient quantities of fibrils to expand work by ORNL and others on heat exchanger tube development. A semicontinuous, microwave heated, vacuum reactor was designed, fabricated and tested in these experiments. Cylindrical aluminum oxide reaction boats are coated, on the inner surface, with a catalyst and placed into the reactor under a light vacuum. A series of reaction boats are then moved, one at a time, through the reactor. Each boat is first preheated with resistance heaters to 850 C to 900 C. Each reaction boat is then moved, in turn, to the microwave heated section. The catalyst is heated to the required temperature of 1200 C to 1300 C while a mixture of MTS (methyl trichlorosilane) and ...
Anomalous features in Gulf Coast Salt domes exhibit deviations from normally pure salt and vary widely in form from one dome to the next, ranging considerably in length and width. They have affected both conventional and solution mining in several ways. Gas outbursts, insolubles, and potash (especially carnallite) have led to the breakage of tubing in a number of caverns, and caused irregular shapes of many caverns through preferential leaching. Such anomalous features essentially have limited the lateral extent of conventional mining at several salt mines, and led to accidents and even the closing of several other mines. Such anomalous features, are often aligned in anomalous zones, and appear to be related to diapiric processes of salt dome development. Evidence indicates that anomalous zones are found between salt spines, where the differential salt intrusion accumulates other materials: Anhydrite bands which are relatively strong, and ...
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical ...
A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...
A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...
Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and with the Reynolds number of 2.9 x 10"3 to ...
The main reasons of tube failures in steam generators (SG) are considered. 1.Stress corrosion craining which has 28% of SG (most of them have stainless steel tubes). 2. Corrosion loss of metal, which accounts for 24% of tubes (phosphate corrosion due to addition of PO into water). 3.Denting-peripheral pressing of tubes in the openings of the foundation plates by the corrosive products, which are formed on internal surface of drillings in the foundation plates made of carbon steel. 4.Separation of a plating layer on tube panels. 5.Dratting-corrosion. 6.Metal fatigue. A series of experiments were conducted to study the influence of material selection on tube reliability (stainless steel 304, inconel-600, mone-400, incalloy-800). The problem of increase of SG elements reliability is a complex one and can be solved by direct selection of material, proper control of ...
Construction of the French PWR nuclear program started in the early 70s, at the time a number of operating plants in the US were being affected by the first corrosion problems. Since, at that time, its construction program was in an early stage, FRAMATOME was able to make modifications on the first units to improve steam generator resistance to corrosion. For instance, full depth expansion of the tubes in the tube-sheet using an explosive process (Westex) was performed on Fessenheim 1 steam generators already installed on site. Later on, continuous operating experience was being obtained in the US, before startup of the French units. This allowed FRAMATOME to react rapidly and take immediate corrective actions at the design stage, during fabrication and sometimes even on site in order to mitigate the risk of corrosion in the steam generators. FRAMATOME is confident that the present design of its steam generator models, including a large number ...
The presentation summarises the highlights of experimental results obtained for VVER type horizontal steam generator heat transfer, primary side flow pattern, and mixing in the hot collector during secondary side boil-off with primary at single-phase natural circulation. The experiments were performed using the PACTEL facility with Large Diameter (LD) steam generator models, with collector instrumentation designed specifically for these tests. The key findings are as follows: (1) the primary to secondary heat transfer degrades as the secondary water inventory is depleted, following closely the wetted tube area; (2) a circulatory flow pattern exists in the tube bundle, resulting in reversed flow (from cold to the hot collector) in the lower part of the tube bundle, and continuous flow through the upper part, including the tubes that have already dried out; and (3) mixing of the hot leg flow entering the ...
A test methodology for measuring temperature, impedance, pH, and electrochemical potential distributions within a sludge-packed tube support plate crevice in a laboratory test is described. The method successfully showed that there were large concentration gradients between the tube and tube support plate sides of the crevice. The testing also showed that strong bases concentrated more effectively than strong acids, and that the crevice pH, when exposed to seawater-based solutions, increased with increasing superheat and decreasing bulk concentration. The large variations in the crevice chemistry observed under heat transfer were eliminated upon shutdown. These new test data suggest that it might be beneficial to evaluate the variation in the extent of stress corrosion cracking with tube support plate elevation found in some steam generators in light of local chemistry changes, as well as the variation ...
Development of a high performance air heater through use of an evacuated tube cover design is described. The cover design utilizes evacuated fluorescent light tubes laid parallel in a close packed array to form an inner transparent glazing over a conventional metal absorber plate with flow behind the plate. A tempered flat glass plate was used as an outer glazing. Both clear and infrared reflective (IR) tubes were investigated. Solar transmittance tests indicate that the clear tube array has a higher transmittance than two flat sheets of low-iron glass. The IR coating produced substantial transmittance loss. Thermal conductance tests indicate that the tubes behave similar to two flat glass sheets with a vacuum in between. The IR reflective coating was only marginally effective at reducing heat conductance. Final prototype designs are presented along with collector performance ...
Constant extension rate (CERT) tests were performed on Alloy 690 and Alloy 800 nuclear steam generator tubing specimens. For the Alloy 690 specimens, tests were performed in deaerated 10% sodium hydroxide solutions at 315 deg C with a +100 mV applied potential. For the Alloy 800 specimens, tests were performed in deaerated 5% sodium hydroxide solutions at 343 deg C with no applied potential. The test specimens were machined from tubing which was produced by different manufacturing processes and in different heat treated conditions. The Alloy 690 tubing was tested in six different thermomechanical conditions, while the Alloy 800 tubing was tested in four different thermomechanical conditions. The results from the test program include a complete microstructural examination using light-optical and scanning electron microscopy. The CERT test results (such as maximum stress achieved and crack morphology) are ...
A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table case. The intrinsic ...
A gas diffusion semiconductor electrode and solar cell and a process for gaseous fixation, such as nitrogen photoreduction, CO/sub 2/ photoreduction and fuel gas photo-oxidation are described. The gas diffusion photosensitive electrode has a central electrolyte porous matrix with an activated semiconductor material on one side adapted to be in contact with an electrolyte and a hydrophobic gas diffusion region on the opposite side adapted to be in contact with a supply of molecular gas.
A simple formulation is presented for torsion analysis of hollow tubes with polygonal shapes. Thicknesses of segments of cross section can be different. Governing equations in term of Prandtl's stress function are used to derive the formulas. The derived formulas are so simple that computations can be carried out with a pocket calculator. Several examples are presented to show the accuracy and efficiency of the formulation. The obtained results are verified by accurate finite element solutions. It will be seen that the derived formulas can be useful for analysis of thin-walled and moderately thick-walled hollow tubes.
Tendency of 12Kh18N10T steel tube samples to intergranular corrosion (IGC) is investigated by an express electrochemical method in the 10% solution of H_2SO_4+0.0025 g/l of KCNS. Tendency to IGC is mainly detected on the internal surface of tube samples. It is shown that the tendency to INC under plant conditions is caused by surface carburization under its incomplete purification from the graphite lubrication.
Nuclear grade production tubing of Alloy 600 was evaluated for stress corrosion cracking (SCC) susceptibility in high purity water at 365, 345, 325, and 290 C. Reverse tube U-bend specimens provided crack initiation data and constant extension rate tests were employed to determine the crack velocities experienced in th crack propagation stage. Initial results indicate that a linear extrapolation of data received from high temperature tests can be used to predict the service life of steam generator tubing that has been plastically deformed or is continually deforming by ''denting.''.
In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.
Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.
The author describes feasibility study on the scheme of disposing spent guide tubes at Daya Bay nuclear power plant, including scheme selection, packing cask design, disposal operation and technological process, budget estimation and safety evaluation. The research results show that the new scheme is feasible on technology, and reasonable on budget. If the scheme is adopted to dispose the spent guide tubes at Daya Bay nuclear power station, it can not only save large funds, but also accumulate experience on disposing non-compressible low and intermediate level solid radioactive wastes produced at nuclear power station for the country
We estimate the optimum electric field at the sheath edge and the minimum interval among the nanotubes to promote the growth of armchair-type nanotubes (metallic character) as a function of the tube length. On the basis of the electric charge distribution in a nanotube and the optimum electric filed E*_1 at the tip of a nanotube evaluated using the Hueckel-Poisson method, we calculate the structure of the electric field lines outside a nanotube in the sheath region. As the tube length increases, the E*_1 decreases. To maintain the chemical activity at the tip, the sheath electric field must be decreased. We show the decreasing rate of the sheath field to the tube length.
Constant property, laminar flow heat transfer in a semicircular tube with uniform wall temperature has been analyzed to define the lower bound of heat transfer augmentation in circular tubes with twisted-tape inserts. Two thermal boundary conditions, which correspond to the two extremes of the fin effect of twisted tapes encountered in practical applications, are considered. Numerical solutions, employing finite-difference formulations for the governing momentum and energy equations were carried out for the thermal entrance region and for fully developed flow.
This paper presents the results of the experimental investigation on heat transfer and fluid friction characteristics of a class of spiral spring coil used as a tube side forced convection heat transfer augmentation devices. Based on a lot of experimental data, the heat transfer correlation and fluid friction correlation revised by temperature were reached in terms of linear regression. At the same time, proper criteria were used to evaluate the economic performance of the spiral spring inserted tube according to the demand of practical application and some probing analysis were made.
The scenario of the development of a new procedure for cutting out the broken protective wells for thermocouples inside the deep holes in the tube plate in the moisture re-heater (MSR) at Daya Bay nuclear power station is presented. Focused in the innovation and improvement of the self-made tools, the new procedure produced an effective method to cut out swing long inserts stuck inside the deep holes. (authors)
An efficient method of hydrogen storage in nano-porous carbons is its reversible sorption by electrochemical decomposition of a KOH water solution according to the following equation: C + xH{sub 2}O + xe{sup -} {yields} (CH{sub x}) + xOH{sup -} where (CH{sub x}) stands for the hydrogen inserted into the nano-porous carbon during charging and oxidized during discharging. Although various carbon materials have been investigated as hydrogen adsorbents, the information about the storage mechanism as well as the nature of the hydrogen/carbon interaction is still not sufficient. In order to extend the understanding of the process, carbon samples charged electrochemically were investigated by temperature programmed desorption (TPD). The nature of the hydrogen/carbon interaction was studied by electrochemical analysis at different temperatures. The TPD experiments consist of heating the samples from room temperature to 950 C and of quantitative analysis by On-line mass ...
... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...
The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.
Objective: To explore the interventional method to treat biliary recurrent jaundice after T tube drainage in patients with malignant obstructive jaundice due to cholangiocarcinoma. Methods: 7 biliary metallic stents were placed in 7 patients with recurrent jaundice after T-tube drainage in cholangiocarcinoma cases. Results: Stent placement was once successful in all 7 cases with successful rate of 100%. For all cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that of preoperation together with subsidence of jaundice satisfactorily for 100% after the treatment. Conclusions: Percutaneous placement of biliary metallic stents was effective economic, minimal invasive and safe for palliation of biliary recurrent jaundice after T tube drainage in cholangiocarcinoma-induced obstructive jaundice
This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...
This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...
Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).
Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe ...
... learn more about the thermal stability of InNP2 Me, a sample contained in a previously evacuated tube was heated at 100°C for 13 days. Neither ...
... Pan Flu Preparedness YouTube is Your Friend Additional Resources ... Response Hurricane Readiness in High-Risk Areas: Survey Results Elements of ...
The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he ...
Turbine Afterword The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he envisioned...
The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.
The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)
The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)
A burner system particularly useful for downhole deployment includes a tubular combustion chamber unit housed within a tubular coolant jacket assembly. The combustion chamber unit includes a monolithic tube of refractory material whose inner surface defines the combustion zone. A metal reinforcing sleeve surrounds and extends the length of the refractory tube. The inner surface of the coolant jacket assembly and outer surface of the combustion chamber unit are dimensioned so that those surfaces are close to one another in standby condition so that the combustion chamber unit has limited freedom to expand with that expansion being stabilized by the coolant jacket assembly so that compression forces in the refractory tube do not exceed about one-half the safe compressive stress of the material; and the materials of the combustion chamber unit are selected to establish thermal gradient parameters across the combustion chamber ...
... Dialysis tubing. Cellulose casing of 1-1/8 inches flat width and an average pore diameter of 48 Angstrom units is used (12,000-14,000 mol wt exclusion). ...
The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...
In order to reduce the size and cost of heat exchangers, an air-side wavy fin-and-tube heat transfer surface with three-row tubes needs to be replaced by two-row tubes with some appropriate enhancing techniques. The major purpose of the present paper is to search for such new structure by numerical simulation. First, longitudinal vortex generators of Delta-winglet type are tried. The influence of number and of arrangement of the winglets on the performance of the heat transfer surface is studied in detail. The numerical results show that the fin with two winglets aligned spanwise in the front and rear of each tube (Fin W6) has higher heat transfer capability than other enhanced structures with vortex generators, but it still unable to meet the heat transfer requirement. Then a combination ...
... with dynamic gridding capability to account for material ablation, as well as the addition of energy sources and heat transfer augmentation due to ...
Sep 19, 2005 ... within a sealed tube to control the environment to which a sample mounts are better suited to handling the very small crystal is exposed. ...
The book tries about the International and national aspects, natural gas situation, production, consumption, prices, demand projection, energetic plans, norms and laws of the natural gas in Colombia
This document provides information on the supply and disposition of natural gas to a wide audience. The 1996 data are presented in a sequence that follows natural gas from it`s production to it`s end use.
The origin of natural gas in the Japanese oil and gas fields are geochemically studied. Samples are taken from structural natural gas, surface gas seepage, water-dissolved natural gas and coal-field gas of the Japan Sea coast area. The origins of primary hydrocarbons are classified into bacteria gas and thermogenic gas, the latter being subclassified into gas in oil production zone with the per million deviation of the carbon isotope (/sup 13/C/sup 1/) of methane less than -35 and those gases with maturity higher than this. Surface gas seepage is subjected to migration and bacterial oxidation. Coal gas is similar to oil gas. The CO/sub 2/ concentration is 0 - 2% and /sup 13/CO/sub 2/ deviations from -30 - +30. The origin can be barely ...
The circulating cooling water flowrate of GNPS and LNPS is totally about 190 m"3/s. Both stations are located on the western coast of semi-closed Daya Bay. A lot of studies concerning thermal impact of GNPS and LNPS have been carried out since 1987, including mathematical model, physical model, on-site survey and satellite remote sensing, etc. This paper describes the hydrological features of Daya Bay and discharge characteristics of circulating water of GNPS and LNPS, estimates the actual thermal impact of GNPS and LNPS, and indicates that it is advantageous for the dilution of circulating water while the two discharge channels of GNPS and LNPS are combined together towards east
In this paper as a result of the theoretical studies and a numerical simulation we presented the following main conclusions: (i) for humid air at increasing pressure of 1.0133 10"5 Pa until 5.0665 10"5 Pa ozone concentrations during 2 centre dot 10"-"3 s become higher in 22 times. This fact we clear with structure of ozone-production reactions. In this case the harmful NO_x concentrations are 2-3 order lower than ozone one; (ii) it is shown that nitrogen is useful to ozone production in the discharge; (iii) based on ion collection we cleared increasing ignition discharge voltage at growing ozone concentrations even with low ozone concentrations.
A large database (507 station-years) of daily suspended particulate matter (SPM) concentration and discharge data from 36 stations on river basins ranging from 600?km2 to 600,000?km2 in size (USA and Europe) was collected to assess the effects of SPM transport regime on bias and imprecision of flux estimates when using infrequent surveys and the discharge-weighted mean concentration method. By extracting individual SPM concentrations and corresponding discharge values from the database, sampling frequencies from 12 to 200 per year were simulated using Monte Carlo techniques. The resulting estimates of yearly SPM fluxes were compared to reference fluxes derived from the complete database. For each station and given frequency, bias was measured by the median of relative errors between estima...
An attempt is made to induce in mud crab (Scylla serrata) epileptiform activities that resemble the generalized epileptic seizures. Cerebral ganglion of crab was exposed in situ, to a convulsant drug pentylenetetrazole (PTZ) 100?mM, for induction of seizures. Also, crabs were pretreated with antiepileptic drug viz sodium valproate (120??mol/l) to inhibit epileptiform activities. The surface electrical discharges of cerebral ganglion were recorded using Unkelscope (MIT, USA) in control as well as experimental animals. The cerebral ganglion of crab showed a pattern of high cerebral electrical discharges after PTZ treatment compared to control. The sodium valproate promoted sedative action in control and prevented PTZ-mediated epileptiform discharges. Glutamate and GABA contents in cerebral g...
Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in ...
Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in ...
Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions and generally increases by 10 to 30 dB in ...
The closed-cycle hydrogen-oxygen PEM regenerative fuel cell (RFC) at Nasa Glenn Research Center has successfully demonstrated closed-cycle operation at rated power for multiple charge/discharge cycles. During the charge cycle the RFC has absorbed input electrical power simulating a solar day cycle ranging from zero to 15 kWe peak, and delivered steady 5 kWe output power for periods exceeding 8 h. Orderly transitions from charge to discharge mode, and return to charging after full discharge, have been accomplished without incident. The RFC is beginning to demonstrate its potential as an energy storage device for aerospace solar power systems such as solar electric aircraft, lunar and planetary surface installations - any airless environment where minimum system weight is critical. This hard...
New methods have been established to enhance the ozone production of the surface discharge arrangement. One method sets the discharge electrode a short distance away from the surface of the dielectric material, whilst another uses a special power supply system resulting in a superimposed discharge. According to the experiments, significant differences have been found in the ozone production capacity of the different arrangements. The characteristics of the electric field distribution of the designs have been calculated using the finite element method for the potential; and the Donor-Cell method for the space charge calculation, and the results have been analysed. A method of analysis has been established for the calculated field characteristics, which provides two index numbers. The reasons are highlighted for the differences in ozone production in relation to the index numbers obtained from the fields' distributions of the ...
Silicon thin film with thickness in range 1000-5300 A deposited on rough Cu foil by a radio frequency magnetron sputtering is used as anode materials for Li-ion rechargeable batteries. The SEM, XRD and TEM analysis reveals that the Si thin film has a floccular nano-sized multi-crystalline structure. Li ions insertion/extraction evaluation is performed mainly with constant current charge/discharge cycling and cyclic voltammetry (CV) at room temperature. The cycleability and reversible discharge capacity are found to depend on the film thickness, and thinner films give larger accommodation capacity. A 3120 A Si film provides a reversible specific capacity over 3500 mA hg{sup -1} with excellent cycleability under 0.5 C charge/discharge rate.
Many older homes are equipped with mercury-containing gas regulators that reduce the pressure of natural gas in the mains to the low pressure used in home gas piping. Removal of these regulators can...Full Text Available
Graphene nanosheets (GNSs) were synthesized and used as cathode active materials in a nonaqueous lithium-oxygen battery. The GNSs electrode delivered an extremely high discharge capacity in comparison to carbon powders, which is attributed to its unique morphology and structure. PMID:21779551
This report presents by state the status of awarded grants, requested grants, and the estimated time required to achieve required control of combined sewer overflow pollution. It also compares discharges of pollutants from treated municipal effluent with ...
Sewage waste disposal facilities in the Florida Keys include septic tanks and individual package plants in place of municipal collection facilities in most locations. In Key Largo, both facilities discharge...Full Text Available
The Nilsson Plate High Frequency Adaptation of the Static Electrification Monitor developed by Electric Research and Management, Inc. for EPRI has demonstrated that the Nilsson Plate can be utilized as a practical high frequency antenna to record partial discharge activity within a transformer. Tests in the ABB factory at Muncie, IN on a 650 MVA, 345/20.9 kV, three-phase unit step-up transformer for TU Electric showed the Nilsson plate detecting partial discharge activity. Although this test was the first attempt at using the Nilsson plate in this manner, and in spite of higher than expected electrical noise levels, the data demonstrated that partial discharges can be detected. The tests also demonstrated that corona activity external to the transformer was not recorded by the plate. Some development work needs to be completed to eliminate the noise source from other monitors on the Static Electrification monitor, and to ...
This manual provides information to assist in selection and designing control measures for reducing pollutant discharges from combined sewer overflows (CSOs). he manual will be useful for municipal public works staff, design engineers, and regulatory agency staff tasked with the ...
The barrier glow discharge between two planar electrodes, covered with dielectric, is studied under high-voltage pulsed power supply. Wide applications of such type of discharges, in particular, for ozone production, stimulated a number of investigations in this direction. In this work we investigated the dependence of ozone concentration on the duration and the rate of pulse rise of the applied voltage. The thyristor converter circuit with the shortening of input pulses on the base of the saturable throttle was used for the realization of this task. The output pulses with amplitude up to 15 kV, repetition frequency of 1 kHz, pulse duration of 0.3 #mu#s (or 7 #mu#s) and the rate of pulse rise of 0.1 #mu#s were generated with this scheme. Measurements of the ozone concentration produced in the air mixture have shown that its value increased by factor two with variation of the rate of pulse rise from 0.5 #mu#s to 0.1 #mu#s (for pulse duration of ...
The report summarizes the environmental significance of the priority pollutants being discharged from thirteen subcategories of the ore mining and dressing point source category. In addition, the impact of proposed effluent limitations guidelines is assessed from an environmental perspective.
MmMg{sub 12}-Ni amorphous or nanocrystalline composites (Mm: Ce-rich mischmetal) were prepared through the ball-milling method, and their electrochemical hydrogen storage performance was investigated and compared with that of ball-milled CeMg{sub 12}-Ni composites. It was found that the ball-milled MmMg{sub 12}-Ni composites had larger initial discharge capacities and better high rate dischargeability. Analysis of electrochemical impedance spectra (EIS) shows that the reaction resistance and hydrogen diffusion resistance of the ball-milled MmMg{sub 12}-Ni composites are lower as a result of the decrease in Ce content, and thus can contribute to the larger discharge capacity and better high rate dischargeability. Additionally, the cycle performance of the ball-milled MmMg{sub 12}-Ni composites is better than those of the ball-milled CeMg{sub 12}-Ni composites. This may be related to the formation of a Nd ...
The effect of atmospheric pressure on tracking resistance of organic insulating materials were investigated in the range of 500 to 1007 hPa. The tracking resistance for Polycarbonate (PC), Modified Polyphenylene Oxide (M-PPO) and Paper Base Phenolic Resin Laminate (PL) increase with the decrease in atmospheric pressure. The scintillating discharges on these samples surface lead to the ignition. The tracking failure on these results from the ignition on the surface. For Polybutylene Terephthalate (PBT) and Polyethylene Terephthalate (PET), the tracking resistance decrease with the decrease in atmospheric pressure. The discharges observed on the these surface are the glow-like. The discharge area spreads on the surface between the electrodes at the lower pressure. The failure on this group results from the carbonization by the discharges on the surface. However, the tracking resistance for Unsaturated ...
We investigated the effects of wastewater treatment plant (WWTP) discharge on the ecology of bacterial communities in the sediment of a small, low-gradient stream in South Australia. The quantification...Full Text Available
A numerical technique is developed for estimating water quality violation frequencies due to pollutant discharges from urban areas during combined sewer overflow events. The first four moments of in-stream pollutant concentration are found by integrating a pollutant loading - wat...
This document is a technical background document for proposed regulations to limit effluent discharges to waters of the United States and introductions of pollutants into publicly owned treatment works from facilities engaged in porcelain enameling. The p...
The stability of a solid ice cover subjected to rapidly varying water levels and discharge was investigated. The support from the bank limits the stress in the ice cover and consequently bank contact must be maintained to ensure ice cover stability. An analysis was required of the stability of ice hinges, a flexible connection between a solid ice cover and the riverbank. Phase II and phase III of the research involved a field study of the Peace River, investigating the evolution of ice hinges with water level variation, from initial ice cover cracking parallel to the banks, to a fully developed hinge. A test program of midwinter discharge variations was undertaken to gather specific data and measurements of ice hinge link length, ice thickness, hinge joint behavior, riverbank geometry, and response of ice hinging to water level variation. This volume of appendices to the study presents detailed observations and comments from field notes through ...
The objective of this retrospective field study was to associate the type and smell of discharge, the size of the uterus, the ovarian and treatment status, and the time to diagnosis of animals with...Full Text Available
The agglomerate for the element is made from activated charcoal powder, an electrically conducting additive and a neutral electrolyte. The activated charcoal makes up 30 to 50 percent of the weight of the agglomerate. It is a mixture of hydrophobized and unhydrophobized powder in a ratio of 85 to 70 to 15 to 30. The element has high discharge characteristics.