WorldWideScience
1

Characterisation of polynuclear aromatic sulfur-heterocycles in a coal extract by GC/MS  

Energy Technology Data Exchange (ETDEWEB)

Polynuclear aromatic sulphur heterocycles (PASHs) were isolated from a coal extract by two-step separation method using silica gel column chromatography and ligand exchanges thin layer chromatography (PdCl{sub 2}/SiO{sub 2}). The subfraction was examined by capillary column gas chromatography with flame ionization detector and flame photometric detector and gas chromatography - mass spectrometry. Identification was accomplished by comparison of chromatographic retention indices and mass spectra of compounds with those reported in the literature. It was found that the principal structures of the sulphur-containing fraction of Guiding coal extract have 3-4 aromatic rings. Dibenzothiophene, C{sub 1} - C{sub 3} alkylated dibenzothiophenes, benzonaphthothiophene and its alkylated derivatives were the main compounds. Only a ...

1994-06-01

2

Determination of the minor disinfection by-products formed in the water plant of Sant Joan Despi (Barcelona, Spain); Determinacion de los subproductos de desinfeccion minoritarios formados en la planta de Sant Joan Despi (Barcelona)  

Energy Technology Data Exchange (ETDEWEB)

Chlorine is widely used in drinking water disinfection due to be a powerful and not expense disinfection. Although the benefits of disinfection, the formation of stable disinfection by-products of the health concern, is the result of the interaction of aqueous chlorine with natural organic matter presents in water. Disinfection by-products generated in major concentration are trihalomethane and haloacetic acids. Disinfection by-products generated in minor concentration are haloacetonitriles, haloketones,chloral hydrate and chloropicrin and some new groups such as cyanogen halides and trihaloacetaldydes. In this work two analytical methods.: headspace/gas chromatography/electron capture detector and liquid-liquid microextraction/gas chromatography/electron capture detector are studied and compared to determine the minor by-products and to establish finally, a ...

1997-09-01

3

Guideline for sampling and analysis of 'tars' and particles in biomass producer gases  

Energy Technology Data Exchange (ETDEWEB)

The further development of a Guideline (formerly Protocol) for sampling and analysis of 'tars' from biomass producer gases is reported. This Guideline is being developed as a project within the European Fifth Framework Programme with additional partners from Switzerland and North-America. In this paper an outline and the principle of the Guideline are given. The Guideline is based on isokinetic sampling of particles and 'tar' from the main producer gas duct, particle filtration at high temperature, gas cooling in a liquid quench, 'tar' absorption in a solvent at low temperatures, an optional backup adsorber, and flow measurement and control. The Guideline gives a definition for 'Gravimetric tar' which is the 'tar' number to be determined by the Guideline. Also, the Guideline gives procedures for compound analysis by gas ...

2000-07-01

4

Effect of different formulations on tebuconazole residues in stone fruits  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND: The correlation between pesticide residue levels and formulation of an active substance is often not considered, even if it is reasonable to expect some differences arising from behaviour during dilution and spraying, from adhesion to plant and from degradation. An experimental study to investigate the magnitude of tebuconazole residues as a function of different tebuconazole formulated products was carried out in Italy. The fungicide was applied as wettable powder (WP) and water-dispersible granule (WG) formulations to peach, plum, apricot and nectarine orchards, on four different sites. The fruit samples gained from the field trials were quantitatively analysed by gas chromatography with a nitrogen phosphorus detector (GC/NPD) for tebuconazole residues. RESULTS: Tebuconazole ...

2009-01-01

5

Sampling and chemical analysis of smoke gas components from the SP Industry Calorimeter  

Energy Technology Data Exchange (ETDEWEB)

This report describes the sampling and chemical analyses of smoke gas components for combustion performed in the SP Industry Calorimeter, where continuous measurements of oxygen, carbon dioxide and carbon monoxide are an integrated part of the Calorimeter system. On-line measurements of nitrogen oxides and total amounts of unburnt hydrocarbons were performed. Hydrogen cyanide, hydrogen chloride and ammonia in the smoke were sampled and absorbed in impinger bottles and subsequently analyzed using wet chemical techniques. An adsorbent sampling system was designed to allow the identification and quantitative analysis of individual organic compounds in the smoke. Gas chromatography was utilized with a mass spectrometric detector for the identification and a FID for quantification of the total amounts as well as individual components. A procedure for cleaning the smoke gas duct in ...

1995-12-31

6

[Determination of sulfite in flue gas desulfurization with seawater by ion chromatography].  

Science.gov (United States)

The technology for flue gas desulfurization (FGD) with seawater is widely adopted by coal-fired power plants in coastal areas. SO2 in the flue gas is absorbed by alkaline seawater and transfered in aqueous phase as sulfite (SO3(2-)), and most SO3(2-) is transformed to sulfate (SO4(2-)) after an aeration process. The remaining SO3(2-) in the seawater discharged to sea area may be harmful to marine organism because of its biological toxicity, thus it is necessary to determine the concentration of SO3(2-) in the seawater for desulfurization. In this study, the method of determination of SO3(2-) in the seawater by ion chromatography was investigated. The separation was achieved on an IonPac AS14A column with 14 mmol/L NaOH-12 mmol/L Na2 CO3 solution as the mobile phase at a flow rate of 1.2 mL/min, and the detection was performed by a pulsed amperometric detector. Formaldehyde was added as a protective ...

2009-11-01

7

Determination of alcohols, esters and organic acids in irradiated sweet potato wine by capillary gas chromatography  

International Nuclear Information System (INIS)

This paper presents the analytical results of alcohols, esters and organic acids in sweet potato wine irradiated by #gamma#-rays. (author).

8

Detection and Identification of Bacteria by Gas Chromatography1  

UK PubMed Central (United Kingdom)

Ether extracts of cultures of 29 strains representing 6 species of Bacillus, and of individual strains of Escherichia coli, Aerobacter aerogenes, and Pseudomonas...Full Text Available

1966-07-01

9

Simultaneous Gas Chromatography-Mass Spectrometry Quantification of Endogenous [12C]- and Applied [13C]Indole-3yl-Acetic Acid Levels in Growing Maize Roots  

UK PubMed Central (United Kingdom)

The use of stable indole-3yl-acetic acid (IAA) labeled by 6 atoms of 13C allowed, after [13C]IAA treatment, simultaneous gas chromatography-mass spectrometry quantifications of...Full Text Available

1991-01-01

10

Persistence of terbufos and its metabolites in soil and maize  

International Nuclear Information System (INIS)

Degradation of "1"4C terbufos was studied under greenhouse conditions. A mixture of "1"4C labelled compound (2.48 x 10"4 Bq of O-ethyl-1- "1"4C) und unlabelled compound (0.09 g of the granule formulation Counter 10 G) was applied to pots containing 750 g of sandy loam clay Ultisol soil with 4.9% organic matter and a cation exchange capacity of 7.6. Two treatments were established, one where maize (cultivar Cristiani) was grown and the other without plants. The soil and plants were extracted at 0, 4, 8, 16, 32 and 64 days and analyzed by a liquid scintillation counter, gas chromatography-flame photometric detector (GC-FPD) and autoradiography. The total "1"4C compounds extracted on day 64 were 31 #+-# 5.6% of the radioactivity applied in the treatments with plants and 46.1 #+-# 1.1% without plants. From the autoradiography results it can be concluded that all times the compounds identified by this technique were terbufos, ...

1996-07-01

11

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

12

Quality engineering and control semiannual progress report November and December 1976 and January--April 1977  

International Nuclear Information System (INIS)

Research and development activities are reported on absorption spectroscopy, calorimetry, electrolysis, emission spectroscopy, fluorimetry gas chromatography, infrared spectroscopy, liquid chromatography, liquid scintillation counting, mass spectroscopy, microscopy, radiometric analysis, and thermal analysis. A group of miscellaneous projects are also described.

13

The thermodynamic characteristics of retention of tricyclo[5.2.1.02,6]decane isomer molecules on different sorbents in gas chromatography  

British Library Electronic Table of Contents (United Kingdom)

The thermodynamic characteristics of sorption of the isomeric tricyclo[5.2.1.02.6]decane (tetrahydrodicyclopentadiene, TDCPD) molecules were for the first time determined experimentally and by molecular statistical methods under the conditions of gas-adsorption chromatography on graphitized thermal carbon black and gas-liquid chromatography on stationary liquid phases of different polarities (Apiezon L and Carbowax 20M). The effects of the chemical nature of sorbents on the retention of the TDCPD isomers are considered. A procedure for calculating the thermodynamic characteristics of adsorption of molecules with a complex structure is suggested within the framework of the atom-atom approximation of the semiempirical molecular statistical theory of adsorption for the example of isostructura...

2008-01-01

14

Separation of 18a(H)-, 18b(H)-oleanane and lupane by comprehensive two-dimensional gas chromatography  

British Library Electronic Table of Contents (United Kingdom)

18a(H)-, 18b(H)-oleanane and lupane are angiosperm-derived biomarkers that are used as age indicators for the Late Cretaceous onwards when the first proliferation of angiosperms occurred. In addition, the 18a(H)-/18b(H)-oleanane ratio is employed as a thermal maturity parameter of crude oil. However, evidence has shown that accurate quantification of these compounds has been impeded by inadequate chromatographic separation by traditional one-dimensional gas chromatography. In this study, we present the separation of 18a(H)-, 18b(H)-oleanane and lupane with comprehensive two-dimensional gas chromatography (GCxGC). Furthermore, it was observed that 18b(H)-oleanane elutes earlier than 18a(H)-oleanane in second dimension (polarity) which we attribute to steric hindrance effects. Two GC conditi...

2011-01-01

15

Radial distribution of bonded fission gas in mixed carbide fuel pins  

International Nuclear Information System (INIS)

The fission gas xenon bonded in bubbles, in pore, and in the lattice of mixed carbide fuels is measured by electron-probe microanalysis. Radial xenon distribution and release curves are determined and are calibrated by gas chromatography of the bonded fission gas and by burnup analysis in the respective pin sections of the irradiation experiments FR2 6A and 6C, Mol 11/K 2, and DFR 330/1. The results are correlated to the microstructure of the fuel, bonding medium, temperature, and burnup. (Auth.).

1979-01-01

16

The conversion of DDT to DDE by some anophelines  

UK PubMed Central (United Kingdom)

The metabolism of DDT has been followed in pure lines of laboratory-reared resistant and susceptible anophelines using gas-liquid chromatography. Relatively large amounts of DDE were formed in...Full Text Available

1964-01-01

17

Stable-Carbon-Isotope Composition of Fatty Acids in Hydrothermal Vent Mussels Containing Methanotrophic and Thiotrophic Bacterial Endosymbionts  

UK PubMed Central (United Kingdom)

Fatty acid biomarker analysis coupled with gas chromatography-isotope ratio mass spectrometry was used to confirm the presence of methanotrophic and thiotrophic bacterial endosymbionts in the tissues...Full Text Available

1998-01-01

18

Nitric Oxide and Nitrous Oxide Production by Soybean and Winged Bean during the in Vivo Nitrate Reductase Assay 1  

UK PubMed Central (United Kingdom)

This study was conducted to determine by gas chromatography (GC) and mass spectrometry (MS) the identity and the quantity of volatile N products produced during the helium-purged in vivo...Full Text Available

1986-11-01

19

Legionella tucsonensis sp. nov. isolated from a renal transplant recipient.  

UK PubMed Central (United Kingdom)

A Legionella-like organism (strain 1087-AZ-H) was isolated from a pleural-fluid specimen from a renal transplant patient undergoing immunosuppressive therapy. Growth characteristics and gas-liquid chromatography...Full Text Available

1989-08-01

20

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

21

Chemical Analysis of Solid-State Irradiated Human Insulin  

British Library Electronic Table of Contents (United Kingdom)

Purpose To study the chemical modifications induced upon irradiation of solid human insulin at radiosterilization doses and investigate the influence of the absorbed dose on radiolysis. Materials and Methods Volatile radiolytic products were monitored by gas chromatography coupled with mass spectrometry (GC-MS) and non-volatile products by two different high performance liquid chromatography (HPLC) methods: the formation of higher molecular weight proteins was assessed by size exclusion liquid chromatography whereas assays for related compounds and chemical potency tests were carried out using reverse-phase HPLC-UV. Conformational changes were investigated by measurements of circular dichroism. Results After gamma irradiation at 10?kGy, the recovery of insulin was 96.8%; higher molecular w...

2006-01-01

22

Decontamination of the chemical warfare agent simulant dimethyl methylphosphonate by means of large-area low-temperature atmospheric pressure plasma  

British Library Electronic Table of Contents (United Kingdom)

Dimethyl methylphosphonate (DMMP), a chemical simulant of the nerve gas GB, was decontaminated with a nonthermal atmospheric pressure plasma. The decontamination efficiency was measured qualitatively by means of Fourier transform spectroscopy and quantitatively by means of gas chromatography. With helium gas only, 10g/m2 of DMMP on an aluminum surface was 99.9% decontaminated in 2min, furthermore, with the addition of 5% of oxygen gas, it was 99.99% decontaminated in 10min. Given the low input power (<100W) and temperature (<75degreeC), this plasma is eligible for nondestructive decontamination of almost all material surfaces.

2009-01-01

23

Analysis of organic sulfur and nitrogen in coal via tandem degradation methods. Technical report, 1 December 1992--28 February 1993  

Energy Technology Data Exchange (ETDEWEB)

N/C and S/C ratios show only minor differences between asphaltenes and coal on this basis, the asphaltenes continue to appear to be good surrogates for the characterization of organic acid rain precursors in coal. Alkylmethoxythiophene carboxylic acids (ATCA) are detected in all dichromate oxidation products analyzed to date. Relative concentrations of ATCA compounds are directly proportional to the sample`s bulk organic sulfur contents. Concentrations of ATCA compounds in oxidation products decrease upon repeated oxidation. This may indicate that the thiophenic groups tend to be located in external positions on the coal macromolecular structure and a high proportion of them can be stripped away with only one mild oxidation step. If true, this may make industrial-scale removal of organic sulfur easier than expected. Using analytical micropyrolysis-gas chromatography with a sulfur-selective flame photometric detector, it is ...

1993-05-01

24

Fundamental understanding of aging processes Review of the workshop results  

CERN Document Server

A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.

2003-01-01

25

The thermodynamic characteristics of retention of tricyclo[5.2.1.02,6]decane isomer molecules on different sorbents in gas chromatography  

Science.gov (United States)

The thermodynamic characteristics of sorption of the isomeric tricyclo[5.2.1.02.6]decane (tetrahydrodicyclopentadiene, TDCPD) molecules were for the first time determined experimentally and by molecular statistical methods under the conditions of gas-adsorption chromatography on graphitized thermal carbon black and gas-liquid chromatography on stationary liquid phases of different polarities (Apiezon L and Carbowax 20M). The effects of the chemical nature of sorbents on the retention of the TDCPD isomers are considered. A procedure for calculating the thermodynamic characteristics of adsorption of molecules with a complex structure is suggested within the framework of the atom-atom approximation of the semiempirical molecular statistical theory of adsorption for the example of isostructural norbornane molecules. The procedure involves simultaneous variation of geometric parameters and refinement of the ...

2008-07-01

26

Novel remote sensing gas outburst detector  

Energy Technology Data Exchange (ETDEWEB)

The possibility has been explored of using a laser scattering technique to detect the imminent onset of rock activity associated with gas outbursts. The instrument described in this paper provides a sensitive, remote and rapid means of passively monitoring micro-seismic activity at the exposed face.

1984-08-01

27

A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))

1994-09-01

28

Henry`s law gas-solid chromatography and correlations of virial coefficients for hydrocarbons, chlorofluorocarbons, ethers, and sulfur hexafluoride adsorbed onto carbon  

Energy Technology Data Exchange (ETDEWEB)

Gas-solid chromatography was used to determine the Henry`s law second gas-solid virial coefficients within the temperature range of 314--615 K for ethane, propane, butane, isobutane, pentane, hexane, heptane, chloromethane, dichloromethane, trichloromethane, tetrachloromethane, trichlorofluoromethane (Freon 11), chlorodifluoromethane (Freon 22), dichlorodifluoromethane (Freon 12), methyl ether, ethyl ether, and sulfur hexafluoride with Carbopack B, a microporous carbon adsorbent. The temperature dependence of the second gas-solid virial coefficients of these adsorbates was used in conjunction with analyses based on a graphical method, a single-surface numeric integration method, a single-surface analytic expression method, and a two-surface analytic expression method to determine the gas-solid interaction energies and other parameters. The interaction energies were correlated with a ...

1995-07-01

29

Synthesis of novel tellurium containing analogues of choline and acetylcholine and their quantitation by pyrolysis-gas chromatography-mass spectrometry.  

Science.gov (United States)

Methods for the synthesis and quantitation of the novel choline analogues, telluronium choline and acetyltelluronium choline, are described. An assay procedure utilizing pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS) with cold trapping was developed with [2H4]telluronium choline and [2H4]acetyltelluronium choline as internal standards. The telluronium compounds were ion-pair extracted from tissue with dipicrylamine, washed with 2-butanone, and pyrolyzed prior to GC-MS analysis. The compounds were monitored using selected ion monitoring at m/z 232 and m/z 190 for acetyltelluronium and telluronium choline, respectively, and at m/z 236 and m/z 194 for the analogous deuterated internal standards. The assay was linear over a range of 20 pmol-20 nmol of compound taken through the assay. PMID:8130881

1993-12-31

30

Metabolite profiling of sucrose effect on the metabolism of Melissa officinalis by gas chromatography-mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

The effect of sugar on plant metabolism, which is known to be similar to hormone-like signaling, was metabolomically studied using Melissa officinalis (lemon balm). The metabolite profiles of M. officinalis treated with sucrose were analyzed by gas chromatography-mass spectrometry (GC-MS) and principal component analysis (PCA). A total of 64 metabolites from various chemical classes including alcohols, amines, amino acids, fatty acids, inorganic acids, organic acids, phosphates, and sugars were identified by GC-MS. Three groups treated with different sucrose concentrations were clearly separated by PCA of their metabolite profiles, indicating changes in the levels of many metabolites depending on the sucrose concentration. Metabolite profiling revealed that treatment with a higher sucrose ...

2011-01-01

31

Gas chromatography - mass-spectrometry of volatiles released from plastics used as building materials  

Energy Technology Data Exchange (ETDEWEB)

The possibility of employing a number of adsorbents (polyphenylquinoxaline, Tenax GC, Carbopak C, graphitized thermal carbon black, silica gels modified with pyrocarbon or hexamethyldisilazane) for the trapping of organic traces from air has been investigated. Adsorption capacities of these adsorbents with respect to a number of volatiles released from certain plastics used as building material (polyvinylchloride, Relin, Acronal, etc.) have been measured. A number of the volatiles were identified by gas chromatography - mass-spectrometry after trapping on the adsorbents investigated. Chromatographic separation after trapping on the adsorbents was carried out on wall-coated open-tubular capillary columns as well as in capillary columns packed with graphitized thermal carbon black.

1983-10-01

32

Behavior of triterpenes from Maytenus aquifolium Martius ('espinheira santa') upon X- and gamma-rays irradiation  

International Nuclear Information System (INIS)

The behavior of the triterpenes friedelin and friedelan-3-ol, contained on the leaves of Maytenus aquifolium Martius (Celastraceae), upon several doses of X- and #gamma#-rays (10 to 100 kGy), was investigated by high resolution gas chromatography (HRGC) and high resolution gas chromatography -mass spectrometry (HRGC-MS). The friedelin content has not changed with #gamma#-irradiation, but the content of friedelan-3-ol decreased around 17% at doses of 10, 20 and 40 kGy and around 27% at doses of 60, 80 and 100 kGy. The levels of both triterpenes remained unchanged even at higher X-ray doses. Lupen-3-one was detected by HRGC-MS. (author).

33

A novel graphene nanosheets coated stainless steel fiber for microwave assisted headspace solid phase microextraction of organochlorine pesticides in aqueous samples followed by gas chromatography with electron capture detection  

British Library Electronic Table of Contents (United Kingdom)

In this study, a novel graphene nanosheets (GNSs) coated solid phase microextraction (SPME) fiber was prepared by immobilizing microwave synthesized GNSs on a stainless steel wire. Microwave synthesized GNSs were verified by X-ray diffraction, field emission-scanning electron microscopy (FE-SEM) and transmission electron microscope (TEM). GNS-SPME fiber was characterized using FE-SEM and the results showed the GNS coating was homogeneous, porous, and highly adherent to the surface of the stainless steel fiber. The performance and feasibility of the GNS-SPME fiber was evaluated under one-step microwave assisted (MA) headspace (HS) SPME followed by gas chromatography with electron capture detection for five organochlorine pesticides (OCPs) in aqueous samples. Parameters influencing the extra...

2011-01-01

34

Post-column reaction detector for platinum(II) antieoplastic agents  

Energy Technology Data Exchange (ETDEWEB)

The development and evaluation of a post-column reaction detector sensitive to platinum(II) complexes is presented in which sodium bisulfite is used as the derivatizing agent with potassium dichromate as an activating agent. The influences of mobile phase changes (i.e., pH, organic modifiers, electrolytes), oxygen, metal ions, and order of reagent addition on reaction kinetics and product yield are defined and used in optimization of detector response. Detection at lambda/sub max/ 290 nm results in an on-line post-column sensitivity of 40-60 ng/mL for selected cis-dichloroplatinum complexes and a sensitivity of 300-1200 ng/mL for four (substituted)-malonato-platinum complexes. The reaction detector is used to monitor the kinetics of aquation of cisplatin (CDDP) and to quantitate CDDP degradation in plasma. As the sensitivity for CDDP in plasma is comparable to that achieved from high pressure liquid ...

1984-03-01

35

Rayleigh Scattering in Rare Gas Liquids  

CERN Document Server

The Rayleigh scattering length has been calculated for rare-gas liquids in the ultraviolet for the frequencies at which they luminesce. The calculations are based on the measured dielectric constants in the gas phase, except in the case of xenon for which measurements are available in the liquid. The scattering length mayplace constraints on the design of some large-scale detectors, using uv luminescence, being proposed to observe solar neutrinos and dark matter. Rayleigh scattering in mixtures of rare-gas mixtures is also discussed.

2002-01-01

36

Quantitation of Indoleacetic Acid Conjugates in Bean Seeds by Direct Tissue Hydrolysis 1  

UK PubMed Central (United Kingdom)

Gas chromatography-selected ion monitoring-mass spectral analysis using [13C6]indole-3-acetic acid (IAA) as an internal standard provides an effective means for quantitation of...Full Text Available

1989-06-01

37

Quality engineering and control. Annual progress report, January-December 1981  

International Nuclear Information System (INIS)

Brief summaries are given of research carried out in the following areas: absorption spectroscopy of titanium, niobium, and molybdenum in uranium alloys; atomic absorption spectroscopy of selenium in stainless steel, computer program improvements for spectrophotometer control, and detection of beryllium in stack gases; electrolysis for inactivation of bacteria in cooling-tower water; improved solvent analysis by gas chromatography; sequential radionuclide separation for various sample matrices; progress on an electron microprobe analyzer; and miscellaneous projects.

38

Distribution of Indole-3-Acetic Acid and the Occurrence of Its Alkali-Labile Conjugates in the Extraxylary Region of Pinus sylvestris Stems 1  

UK PubMed Central (United Kingdom)

Free and conjugated indole-3-acetic acid (IAA) were measured by quantitative gas chromatography-selected ion monitoringmass spectrometry in the extraxylary region of the stem of large Pinus...Full Text Available

1990-08-01

39

The mass dependence of the signal peak height of a Bragg-curve ionization chamber  

International Nuclear Information System (INIS)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).

40

Mass dependence of the signal peak height of a Bragg-curve ionization chamber  

Energy Technology Data Exchange (ETDEWEB)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.

1985-01-01

41

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

42

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

43

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and ...

1991-09-01

44

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and ...

45

Structure-retention correlations of hydrocarbons in gas-liquid and gas-solid chromatography. Cycloalkenes and cycloalkadienes  

Energy Technology Data Exchange (ETDEWEB)

The retention indices of cycloalkenes and cycloalkadienes with C/sub 6/-C/sub 13/ rings are determined by gas-liquid chromatography (GLC) on glass capillary columns coated with OV-1 and Ucon LB 550X and by gas-solid chromatrography (GSC) on a microcolumn packed with uncoated graphitized thermal carbon black (GTCB). Structure-retention correlations are derived on using index differences such as H/sup OV/, H/sup GTCB/ and ..delta..I values, considering the differences in the stereochemistry of these compounds. It is shown that the combined application of index increments obtained in GLC and GSC provides more detaled structure informations. The value of the retention index units agree with the most stable conformations of the alicyclic compounds. The high value for the energy equivalent to an index unit (..delta..G/sub I.U./ = 4.18 kJ/mol) confirms that graphitized thermal carbon black causes much stronger dispersive ...

1987-08-01

46

Monitoring amino acids, organic acids, and ripening changes in Cheddar cheese using Fourier-transform infrared spectroscopy  

British Library Electronic Table of Contents (United Kingdom)

Fourier-transform infrared (FTIR) spectroscopy was used to monitor amino acids, organic acids, and changes during ripening. Twelve Cheddar cheese samples were ripened for 73 days and samples were drawn periodically. Water-soluble fractions of samples were analyzed by gas chromatography (20 amino acids), liquid chromatography (three organic acids), and FTIR spectroscopy (4000-700 cm-1). Spectra were correlated with chromatographic data and ripening events and analyzed by multivariate statistics to develop prediction and classification models. Most models showed a good fit (correlation coefficient > or =0.89) and could predict the levels of amino acids and organic acids and age of the cheese in less than 20 min. Lactic acid, leucine, glutamic acid, asparagine, phenylalanine, and valine were ...

2011-01-01

47

Identifying fade mechanisms in high-power lithium-ion cells.  

Energy Technology Data Exchange (ETDEWEB)

Hybrid electric vehicles (HEV) need long-lived high-power batteries as energy storage devices. Batteries based on lithium-ion technology can meet the high-power goals but have been unable to meet HEV calendar-life requirements. As part of the US Department of Energy's Advanced Technology Development (ATD) Program, diagnostic studies are being conducted on 18650-type lithium-ion cells that were subjected to accelerated aging tests at temperatures ranging from 40 to 70 C. This article summarizes data obtained by gas chromatography, liquid chromatography, electron microscopy, X-ray spectroscopy and electrochemical techniques, and identifies cell components that are responsible for the observed impedance rise and power fade.

2004-01-01

48

A nontoxic antitumour compound from the leaves of Bauhinia scandens characterized as 1-O-alkyl glycerol by gas-liquid chromatography and evaluation of its antitumour property by Brine Shrimp bioassay  

British Library Electronic Table of Contents (United Kingdom)

This is a report of extraction and identification of 1-O-alkyl glycerol present in the dried leaves of Bauhinia scandens. Fifty percent aqueous ethanolic extract of the plant at room temperature was fractionated over petroleum ether and diethyl ether. The diethyl ether soluble fraction showed positive bioactivity in Brine Shrimp bioassay. Isolation and purification of the active principle was subsequently done from diethyl ether fraction. The diethyl ether fraction was separated into acidic and neutral part. The acid free fraction was screened to be positive in Brine Shrimp bioassay. The NMR spectra (in CDCl3) indicated the probability of its lipoidal nature. The total lipid fraction was resolved into neutral, glyco, and phospho-lipids by column chromatography. Only the neutral fraction sh...

2008-01-01

49

Indoor and outdoor Radon concentration measurements in Sivas, Turkey, in comparison with geological setting  

British Library Electronic Table of Contents (United Kingdom)

Indoor and soil gas Radon (222Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor 222Rn gas concentration values. In the second stage, soil gas 222Rn measurements were performed using an alphameter near the selected h...

2010-01-01

50

Confirmatory analysis method for zeranol, its metabolites and related mycotoxins in urine by liquid chromatography-negative ion electrospray tandem mass spectrometry  

Energy Technology Data Exchange (ETDEWEB)

The determination of the banned anabolic substance zeranol and the metabolites taleranol and zearalanone in bovine urine is complicated by the occurrence of the structurally-related mycotoxin zearalenone and the corresponding {alpha}- and {beta}-zearalenol metabolites which possess similar estrogenic properties. A liquid chromatography-negative ion electrospray tandem mass spectrometric method is presented for the confirmatory analysis of all six resorcylic acid lactones ('zeranols') in urine samples using deuterium-labelled internal standards. The method was validated as a confirmatory method for bovine urine samples according to new draft EU guidelines and showed good precision and linearity, and CC{alpha} and CC{beta} values of 0.02-0.30 and <1.0 ng ml{sup -1}, respectively. The applicability was demonstrated by comparing the results of an incurred sample with previous results on the same sample obtained by gas ...

2002-11-25

51

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

52

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

53

A gas chromatographic analysis of phosphine in biological material in a case of suicide  

British Library Electronic Table of Contents (United Kingdom)

In a suicide committed using aluminium phosphide (AlP) the liberated toxic phosphine gas was detected in post-mortem specimens using a headspace gas chromatographic procedure with a nitrogen-phosphorous detector (HS-GC/NPD). At autopsy a direct sampling into airtight headspace vials for a later analysis is recommended. AlP has to be considered a potent pesticide and its use and availability should be restricted as much as possible.

2008-01-01

54

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

55

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

56

First tests of "bulk" MICROMEGAS with resistive cathode mesh  

CERN Document Server

We present the first results from tests of a MICROMEGAS detector manufactured using the so-called "bulk" technology and having a resistive cathode mesh instead of the conventional metallic one. This detector operates as usual MICROMEGAS, but in the case of sparks, which may appear at high gas gains, the resistive mesh reduces their current and makes the sparks harmless. This approach could be complementary to the ongoing efforts of various groups to develop spark-protected MICROMEGAS with resistive anode planes.

2010-01-01

57

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

58

MAGIC - Multi Anode Gas Ionization Chamber  

Energy Technology Data Exchange (ETDEWEB)

A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))

1994-12-01

59

The composition-explicit distillation curve technique: Relating chemical analysis and physical properties of complex fluids.  

Science.gov (United States)

The analysis of complex fluids such as crude oils, fuels, vegetable oils and mixed waste streams poses significant challenges arising primarily from the multiplicity of components, the different properties of the components (polarity, polarizability, etc.) and matrix properties. We have recently introduced an analytical strategy that simplifies many of these analyses, and provides the added potential of linking compositional information with physical property information. This aspect can be used to facilitate equation of state development for the complex fluids. In addition to chemical characterization, the approach provides the ability to calculate thermodynamic properties for such complex heterogeneous streams. The technique is based on the advanced distillation curve (ADC) metrology, which separates a complex fluid by distillation into fractions that are sampled, and for which thermodynamically consistent temperatures are measured at atmospheric pressure. The collected sample ...

2009-11-17

60

Gas sensor arrays (electronic noses) and their combination with trap techniques  

Energy Technology Data Exchange (ETDEWEB)

In the food, chemical and safety industry there is a demand for gas detectors for process control applications, like quality control of food or leakage control in chemical plants. Gas sensor array systems have the potential to be used in this areas, with the advantage of being also affordable systems compared to other systems like gaschromatographs (GC) or infrared detectors (NIR, FTIR). One of the main drawbacks of the gas sensors is their response to non interesting ambient factors like temperature, pressure and humidity. Metal oxide sensors (MOS) have a low ambient temperature and pressure dependency. Some of them (SnO + dopands) have some sensitivity to humidity. In many cases the response of the sensors is often non-linear, which implies a concentration dependant pattern of the samples. (orig.)

2001-07-01

62

Chromatography Equipment on Environmental Expert  

Wastenet

...for free Subscribe your products Categories All Categories Monitoring & Testing ChromatographyDelete Category Filter anion exchange chromatography biogas chromatographs chromatographic media chromatographic separations chromatographs chromatography ...

63

Intercomparison of Retrospective Radon Detectors  

Energy Technology Data Exchange (ETDEWEB)

We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated ...

1998-11-01

64

Low-temperature oxidative degradation of PBX 9501 and its components determined via molecular weight analysis of the Poly[ester urethane] binder  

British Library Electronic Table of Contents (United Kingdom)

The results of following the oxidative degradation of a plastic-bonded explosive (PBX 9501) are reported. Into over 1100 sealed containers were placed samples of PBX 9501 and combinations of its components and aged at relatively low temperatures to induce oxidative degradation of the samples. One of the components of the explosive is a poly(ester urethane) polymer and the oxidative degradation of the samples were following by measuring the molecular weight change of the polymer by gel permeation chromatography (coupled with both differential refractive index and multiangle laser light scattering detectors). Multiple temperatures between 40 and 64 degreeC were used to accelerate the aging of the samples. Interesting induction period behavior, along with both molecular weight increasing (cro...

2009-01-01

65

Study on the stability of the Maytenus aquifolium Martius chemical components submitted to ionizing radiation (X-ray and #gamma#)  

International Nuclear Information System (INIS)

The interest for medicinal plants has raised again in the last decades, after overcoming a declination period caused by the advances in the researches and development of the synthetic drugs industries. This growing interest has been stimulated mainly by searching cheap and accessible alternative therapies. However, in order to have natural products based treatment in an efficient and safety way, it is necessary to guarantee the plant authenticity, finding adulterations and to assure a low level of microbiological contaminations to avoid damages to consumer's health. The decontamination method should be chosen for eliminating or reduce the microorganisms level without loss of the plant active constituents that would destroy its therapeutic action. At the present work, the possibility of using #gamma# and X electromagnetic radiations to sterilize a Brazilian medicinal plant (Maytenus aquifolium Martius, Celastraceae), which shows anti-ulcer activity, was studied by accomplishing its ...

66

Optimization of equilibrium headspace analysis of volatile flavor compounds of malaysian soursop (Annona muricata): Comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC-TOFMS)  

British Library Electronic Table of Contents (United Kingdom)

Headspace solid-phase microextraction (HS-SPME) coupled to comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry (GCxGC-TOFMS) was applied for equilibrium headspace analysis of Malaysian soursop (Annona muricata) volatile flavor compounds. A two-level fractional factorial design (25-1) was used to determine the effect of SPME variables, namely, SPME fibers, adsorption temperature, extraction time, amount of salt, sample amount and sample concentration on the extraction efficiency of volatile flavor compounds. A total of 37 volatile compounds were identified, comprising 21 esters, 6 alcohols, 3 terpenes, 2 acids, 2 ketones, 2 aldehydes and an aromatic with different hydrophobicities (log P) ranging between -0.14 and 4.83. Extraction using 10g of diluted (5% w/w) ...

2011-01-01

67

Analysis of Automotive Paints using Pyrolysis-Gas Chromatography  

Energy Technology Data Exchange (ETDEWEB)

The automotive paints could be generally differentiated by color, layer sequence and chemistry of the paint layers comprising each of the topcoat and the primer system. The successful identification of hit-and-run a and traffic accidental vehicles from evidential paint fragments is greatly facilitated with a comprehensive laboratory collection of reference paint samples and the technique for direct analysis without sample preparation. The Pyrolysis-Gas Chromatography(PGC) is a precise and reliable method for performing both quantitative and qualitative analysis of polymeric materials and forensic samples. Our Forensic Laboratory is conducting the examination and identification of 73 reference paint samples; 4 colors of each domestic automotive make that is poplar in Korea, by Curie Point Pyrolyzer(JHP-3) and GC with capillary column(ultra alloy-5). This method can be used not only to compare paint traces with their suspected sources, but also ...

2000-02-01

68

Adsorption properties of. cap alpha. -modification of boron nitride  

Science.gov (United States)

The adsorption properties of four samples of ..cap alpha..-BN were studied by means of gas chromatography. The particles of ..cap alpha..-BN particles, according to data obtained by electron microscopy, have the shape of thin platelets. A sample of ..cap alpha..-BN prepared from magnesium polyboride was found to be the most nearly homogeneous adsorbent. For a number of n-alkanes, benzene, and alkylbenzenes, data have been obtained on the retention volumes (Henry constants) and the differential heats of adsorption for surface coverages approaching zero. These thermodynamic data on the adsorption showed that ..cap alpha..-BN, like graphitized thermal carbon black, is a nonspecific adsorbent.

1986-11-01

69

Anode wire ageing in proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

Experimental results of ageing effects in proportional counters are presented. The measurements were carried out for 158 ZEUS-BAC gas system monitoring counters. Deterioration of the pulse height distribution in azimuth and along the anode wire are presented. The influence of water admixture on counting gas is also described. (orig.).

1997-06-21

70

Indoor and outdoor Radon concentration measurements in Sivas, Turkey, in comparison with geological setting  

Energy Technology Data Exchange (ETDEWEB)

Indoor and soil gas Radon ({sup 222}Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor {sup 222}Rn gas concentration values. In the second stage, soil gas {sup 222}Rn measurements were performed using an alphameter near the selected houses for the indoor measurements. Although {sup 222}Rn ...

2010-11-15

71

Thermoelectrically cooled water trap  

Energy Technology Data Exchange (ETDEWEB)

A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.

2006-02-21

72

Effect of ionizing radiation on the properties of PLA packaging materials  

International Nuclear Information System (INIS)

Poly(lactic acid) (PLA) is attractive as a substitute for classical polymer packaging material due to its biodegradability and sufficient mechanical and barrier properties. Presented research was focused on the changes of basic mechanical parameters after ionizing irradiation performed with doses in the range of 2.5-25 kGy, commonly used in radiation sterilization and preservation of foods. Two commercial available PLA packaging films were tested. The influence of radiation dose on the mechanical properties - tensile strength and elongation were determined using standardized methods. Radiation resistance of PLA is sufficient for packaging applications. The investigations of gas products of radiolysis of PLA have been made by gas chromatography after electron beam (EB) irradiations. (authors)

73

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of ...

2009-11-02

74

Monitoring of the insecticide trichlorfon by phosphorus-31 nuclear magnetic resonance ({sup 31}P NMR) spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

Trichlorfon is an organophosphorus insecticide, which is extensively being used for protection of fruit crops. Trichlorfon is a thermal labile compound, which cannot be easily determined by gas chromatography (GC) and has no suitable group for sensitive detection by high performance liquid chromatography (HPLC). In this study, a {sup 31}P nuclear magnetic resonance ({sup 31}P NMR) has been described for monitoring of trichlorfon without any separation step. The quantitative works of {sup 31}P NMR spectroscopy has been performed in the presence of an internal standard (hexamethylphosphoramide). Limit of detection (LOD) for this method has been found to be 55 mg L{sup -1}, without any sample preparation, and the linear working range was 150-5500 mg L{sup -1}. Relative standard deviation (R.S.D.%) of the method for three replicates within and between days was obtained {<=}9%. The average recovery efficiency was ...

2006-08-25

75

Quantitation of Antibiotics by High-Pressure Liquid Chromatography: Cephalothin  

UK PubMed Central (United Kingdom)

A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available

1978-02-01

76

Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies  

International Nuclear Information System (INIS)

A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 refs., 2 figs.

77

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; ...

1982-12-01

78

Plasma chemistry in wire chambers  

Energy Technology Data Exchange (ETDEWEB)

The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of ...

1990-05-01

79

Direct combustion of olive cake using fluidized bed combustor  

Energy Technology Data Exchange (ETDEWEB)

A fluidized bed combustor of 0.146 m diameter and 1 m length was fabricated from stainless steel to burn olive cake. Initially, and in order to obtain fluidization, the system was operated under cold conditions using a sand with particle size in the range of 500 to 710 microns. The continuous combustion experiments were carried out under controlled conditions, such that the effects of bed temperature, olive cake feed rate, fluidization velocity, and particle size on combustion efficiency and flue gas composition were investigated. It was found that the combustion efficiency decreases with the bed temperature, fluidization velocity, and the feed rate, while it increases with the particle size used. Further, the gas products analysis carried out using a gas chromatography analyzer have shown a nonmeasured amount of SO2, and small amounts of CO. Finally, the temperature distribution along the bed indicated ...

1999-04-15

80

Conversion of char nitrogen to N2 under incomplete combustion conditions; Fukanzen nensho jokenka ni okeru char chuchisso no N2 eno tenka  

Energy Technology Data Exchange (ETDEWEB)

The effect of combustion conditions on conversion of char nitrogen to N2 was studied in the combustion experiment of char obtained by pyrolysis of coal. Char specimen was prepared by holding ZN coal of Chinese lignite in Ar atmosphere at 1123K for one hour. A batch scale quartz-made fluidized bed reactor was used for combustion experiment. After the specimen was fluidized in reaction gas, it was rapidly heated to start combustion reaction. CO, CO2 and N2 in produced gases were online measured by gas chromatography (GC). As the experimental result, under the incomplete combustion condition where a large amount of CO was produced by consuming almost all of O2, no NOx and N2O produced from char were found, and almost all of N-containing gas was N2. At the final stage of combustion, pyridinic-N disappeared completely, and pyrrolic-N decreased, while O-containing nitrogen complexes became a main component. ...

1996-10-28

81

Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia  

Energy Technology Data Exchange (ETDEWEB)

Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification ...

2006-07-01

82

Use of Multiwalled Carbon Nanotubes as a SPE Adsorbent for Analysis of Carfentrazone-Ethyl in Water  

British Library Electronic Table of Contents (United Kingdom)

Solid-phase extraction and gas chromatography with electron-capture detection has been used for sensitive, simple, and reliable analysis of carfentrazone-ethyl residues in water. Carfentrazone-ethyl was enriched by use of multiwalled carbon nanotubes (MWCNT), a new adsorptive material. Several conditions affecting recovery of the analyte, for example polarity and volume of eluents, pH of water samples, and sample volume, were studied. Recovery from fortified samples, linear range, and limit of detection were evaluated. The results showed that MWCNT are an efficient SPE adsorbent for preconcentration of carfentrazone-ethyl in water. Under the optimized SPE conditions, recovery of carfentrazone-ethyl from fortified water was 81.49?91.08%, with RSD from 1.66 to 8.21%. The limits of detection ...

2009-01-01

83

Safety testing of 18650-style Li-Ion cells  

Energy Technology Data Exchange (ETDEWEB)

To address lithium-ion cell safety issues in demanding power applications, electrical and thermal abuse tests were performed on 18650 sized cells. Video and electrically monitored abuse tests in air included short circuit, forced overcharge, forced reversal, and controlled overheating (thermal) modes. Controlled overheating tests to 200 C were performed in a sealed chamber under a helium atmosphere and the gases released from the cell during thermal runaway were analyzed at regular intervals using gas chromatography and mass spectrometry. In addition to alkane and alkene solvent breakdown fragments, significant H{sub 2} was detected and evidence that HF was evolved was also found.

2000-06-08

84

Potential migration of organic pollutants in pipes of polyethylene. Study in pipelines of distribution net of drinkable water; Migracion potential de contaminantes organicos en tubos de polietileno. Estudio en tuberias de red de distribuciond e agua potable  

Energy Technology Data Exchange (ETDEWEB)

Polyethylene pipes and connections are being widely used in treated water distribution services. Migration of low molecular weight compounds from the polyethylene into the water can change its final quality. This paper is about the concentrations and identification of the migration compounds found in treated water after staying in contact with low and high-density polyethylene. Identification and quantification were carried out using CLSA (Closed Loop Stripping Analysis) extraction technique and gas chromatography coupled to mass spectrometry (HRGC/HRMS). (Author) 12 refs.

2002-07-01

85

Molecular statistical calculation of thermodynamic characteristics of adsorption of O-, S-, and Se-containing heteroadamantanes on graphitized thermal carbon black  

British Library Electronic Table of Contents (United Kingdom)

The thermodynamic characteristics of adsorption (TCA) on the basal face of graphite have been calculated in terms of the semiempirical molecular statistical theory of adsorption for molecules of O-, S-, and Se-containing heteroadamantanes of different structure and isostructural cyclohexane derivatives. The influence of the nature, number, and position of heteroatoms in the adamantane framework on the TCA values was studied in detail, which made it possible to predict the retention of the compounds considered on the surface of graphitized thermal carbon black under the conditions of equilibrium gas adsorption chromatography. The introduction of each subsequent heteroatom into a polyheteroadamantane molecule makes a non-additive contribution to the TCA values. The contributions of various f...

2010-01-01

86

Investigation of the aroma impact volatiles in Turkish pine honey samples produced in Marmaris, Data and Fethiye regions by SPME/GC/MS technique  

British Library Electronic Table of Contents (United Kingdom)

Summary The aroma impact volatiles of twenty-four pine honey samples produced in Marmaris, Data and Fethiye regions of Turkey were evaluated by solid phase micro extraction/gas chromatography/mass spectrometry (MS) technique and the results were evaluated by using the analysis of variance and Duncan tests. A total of eight common volatiles nonanal, nonanol, decanal, octanal, 16-oxosalutaridine, dodecanal, nonadecane and pentadecane were detected in three regions. The total area of the common volatiles were 73.01%, 78.10% and 73.91% in Marmaris, Data, and Fethiye regions, respectively. There were not significant differences (P-<-0.05) between the common volatiles detected in pine honey samples from three different regions. The major contributers to the pine honey aroma seems to be nonanal (...

2011-01-01

87

Fragranced consumer products: Chemicals emitted, ingredients unlisted  

British Library Electronic Table of Contents (United Kingdom)

Fragranced consumer products are pervasive in society. Relatively little is known about the composition of these products, due to lack of prior study, complexity of formulations, and limitations and protections on ingredient disclosure in the U.S. We investigated volatile organic compounds (VOCs) emitted from 25 common fragranced consumer products-laundry products, personal care products, cleaning supplies, and air fresheners-using headspace analysis with gas chromatography/mass spectrometry (GC/MS). Our analysis found 133 different VOCs emitted from the 25 products, with an average of 17 VOCs per product. Of these 133 VOCs, 24 are classified as toxic or hazardous under U.S. federal laws, and each product emitted at least one of these compounds. For ''green'' products, emissions of these c...

2011-01-01

88

Flame retardancy of polybutylene terephthalate blended with various oxides  

British Library Electronic Table of Contents (United Kingdom)

The flame retardancy of polybutylene terephthalate (PBT) was studied focusing on the effect of various oxides. Thermo-gravimetric analysis, pyrolysis/gas chromatography/mass spectrometry, and elemental analysis (EA) were used to analyze the flame retardancy, which were observed through the UL-test and a cone calorimeter. Many oxides influenced the flame retardancy and some of them could suppress the flammability of PBT. In particular, the blended-PBTs with ZnO and V2O5 accelerated the degradation and the edges of oxygen consumption were shorter than neat-PBT although the flammability became poorer. The quantitative analysis of the scission products and the results of EA showed that hydrolysis, successive dehydration, and other various reactions changed the scission route to generate less f...

2008-01-01

89

Drug detection in breath: effects of pulmonary blood flow and cardiac output on propofol exhalation  

British Library Electronic Table of Contents (United Kingdom)

Breath analysis could offer a non-invasive means of intravenous drug monitoring if robust correlations between drug concentrations in breath and blood can be established. In this study, propofol blood and breath concentrations were determined in an animal model under varying physiological conditions. Propofol concentrations in breath were determined by means of two independently calibrated analytical methods: continuous, real-time proton transfer reaction mass spectrometry (PTR-MS) and discontinuous solid-phase micro-extraction coupled with gas chromatography mass spectrometry (SPME-GC-MS). Blood concentrations were determined by means of SPME-GC-MS. Effects of changes in pulmonary blood flow resulting in a decreased cardiac output (CO) and effects of dobutamine administration resulting in...

2011-01-01

90

Degradation of antibiotics in water by non-thermal plasma treatment.  

Science.gov (United States)

The decomposition of three ?-lactam antibiotics (amoxicillin, oxacillin and ampicillin) in aqueous solution was investigated using a dielectric barrier discharge (DBD) in coaxial configuration. Solutions of concentration 100 mg/L were made to flow as a film over the surface of the inner electrode of the plasma reactor, so the discharge was generated at the gas-liquid interface. The electrical discharge was operated in pulsed regime, at room temperature and atmospheric pressure, in oxygen. Amoxicillin was degraded after 10 min plasma treatment, while the other two antibiotics required about 30 min for decomposition. The evolution of the degradation process was continuously followed using liquid chromatography-mass spectrometry (LC-MS), total organic carbon (TOC) and chemical oxygen demand (COD) analyses. PMID:21514950

2011-04-06

91

Chemically authentic surrogate mixture model for the thermophysical properties of a coal-derived liquid fuel  

Energy Technology Data Exchange (ETDEWEB)

We developed a surrogate mixture model to represent the physical properties of a coal-derived liquid fuel using only information obtained from a gas chromatography-mass spectrometry analysis of the fuel and a recently developed 'advanced distillation curve'. We then predicted the density, speed of sound, and viscosity of the fuel and compared them to limited experimental data. The surrogate contains five components (n-propylcyclohexane, trans-decalin, {alpha}-methyldecalin, bicyclohexane, and n-hexadecane), yet comparisons to limited experimental data demonstrate that the model is able to represent the density, sound speed, and viscosity to within 1, 4, and 5%, respectively. 102 refs., 2 figs., 5 tabs.

2008-09-15

92

Chemical stability of {gamma}-butyrolactone-based electrolytes for aluminium electrolytic capacitors  

Energy Technology Data Exchange (ETDEWEB)

{gamma}-Butyrolactone-based electrolytes have been used as the operating electrolytes for aluminum electrolytic capacitors. The chemical stability of these electrolytes at elevated temperatures has been examined by monitoring the decrease in their electrolytic conductivities. The deteriorated electrolytes were analyzed by gas and liquid chromatography and the conductivity decrease was directly correlated with the loss of acid components. In quaternary ammonium hydrogen maleate/{gamma}-butyrolactone electrolytes, the maleate anion decomposed by decarboxylation resulting in a complex polymer containing polyester and polyacrylate structures. Quaternary ammonium benzoate/{gamma}-butyrolactone electrolytes decomposed by SN2 reactions giving alkyl benzoates and trialkylamines. The deterioration of the carboxylate salt/{gamma}-butyrolactone electrolytes was accelerated by electrolysis. (orig.)

1996-06-01

93

Biosorption and biodegradation interactions - a study on lindane  

Energy Technology Data Exchange (ETDEWEB)

The kinetics of biosorption and desorption of lindane by live activated sludge and the fungus R. arrhizus was studies. The results from the use of live activated sludge suggest that besides biosorption, other lindane removal mechanisms acted in parallel. Most probably, biodegradation. A relationship between biodegradation and bisorption-desorption was established. Mass spectroscopy and gas chromatography studies suggested the presence of lindane biodegradation by products. Lindane accumulated by the live activated sludge could be desorbed while being biodegraded at the same time. Values for lindane biokinetic constants were estimated. Biosorption of lindane by live R. arrhizus is a rapid and reversible process with no indication of biodegradation. Values for the lindane biotransformation kinetic coefficients were estimated. (orig.).

1991-03-01

94

A Comparative Study of Hydrodistillation and Hydrodistillation?Solvent Microextraction Methods for Identification of Volatile Components of Echinophora cinerea  

British Library Electronic Table of Contents (United Kingdom)

A recently developed hydrodistillation?solvent microextraction (HD?SME) method coupled to gas chromatography?mass spectrometry (GC?MS) was applied to the analysis of volatile components of aerial parts of Echinophora cinerea (Boiss). By the use of a simplex optimization method, the effects of extraction time, sample weight and microdrop volume on the extraction efficiency of the method were optimized. In the optimized conditions, 3??L of n-heptadecane was suspended in the headspace of 6?g of hydrodistillating sample, using a microsyringe. After 7?min, the solvent was retracted back into the syringe and directly injected into the GC?MS injection port. The HD?SME method was compared to a conventional hydrodistillation technique. In general, the extraction with HD?SME was relatively faster an...

2009-01-01

95

Determination of Cinchona alkaloids and Vitamin B_6 by high-performance liquid chromatography with fluorescence detection  

International Nuclear Information System (INIS)

A simple and specific method has been developed for the simultaneous determination of the four major Cinchona alkaloids and their dihydroderivatives and pyridoxine hydrochloride (Vitamin B_6) by high-performance liquid chromatography (HPLC) with fluorescence detection (#lambda#_e_m=420 nm with #lambda#_e_x=330 nm). The chromatographic separation was performed on a Phenomenex Prodigy ODS column (5 #mu#m, 250 mmx3.2 mm i.d.), recommended for basic compounds, under isocratic reversed-phase conditions. The method allowed a good peak shape and an effective resolution of the tested compounds. The extraction of alkaloids from the Cinchona succirubra bark was carried out in mild and fast conditions (ambient temperature, 20 min) by ultrasonication. The procedure showed to be advantageous respect to a reference method, which involved Soxhlet extraction. The results were compared statistically by means of the Student's t-test and the variance ratio F-test; no significant ...

2004-06-04

96

Determination of carboxylic acids in oxidised engine oils by liquid chromatography with cemiluminiscence detection  

Energy Technology Data Exchange (ETDEWEB)

A procedure for the determination of carboxylic acids (benzoic and C{sub 8}-C{sub 16} aliphatic acids) in oxidised engine oils is described. It is based on a simple and selective derivatisation of the acids with a fluorescent label 9-anthracene-methanol followed by reverse-phase separation on an ODS column with a water-acetonitrile-tetrahydrofuran (20:40:40 by volume) mobile phase and post-column reaction with bis(2,4-dinitrophenyl) oxalate and hydrogen peroxide. The chemiluminiscence emission from the reaction was monitored using a lamina flow-through detector. Analysis of oxidised oils showed that although there was quenching of chemiluminiscence emission by the oil matrix, the acids could be determined over the range 0-0.4% (m/v) in the oil with a detection limit of 0.013% (m/v) (130 pmol on-column with a 20 {mu}l injection) for lauric acid. 8 figs., 2 tabs., 17 refs.

1992-09-01

97

Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron ...

2010-09-07

98

Extreme Ultraviolet Emission from Abell 4059  

CERN Document Server

We present the results of a search for Extreme Ultraviolet emission in A4059, a cluster with an X-ray emitting cluster gas. Our analysis of Extreme Ultraviolet Explorer (EUVE) Deep Survey observations of this cluster shows that it is associated with diffuse EUV emission. Outside the central 2 arcmin radius the entire EUV emission detected is explained by the low energy tail of the X-ray emitting gas. Within the central 2 arcmin region of the cluster we find a deficit of EUV emission compared to that expected from the X-ray gas. This flux deficit is discussed in the context of the cluster's cooling flow. The results derived for A4059 are compared to EUVE results obtained for other clusters such as Coma, Virgo, A1795, and A2199. As part of the study we have carried out a detailed investigation of the stability of the EUVE Deep Survey detector background. Based on long integrations of blank sky over 27 ...

2000-01-01

99

Method for determining hydrogen mobility as a function of temperature in superconducting niobium cavities  

Energy Technology Data Exchange (ETDEWEB)

A method for determining the mobility of hydrogen as a function of temperature in superconducting niobium cavities comprising: 1) heating a cavity under test to remove free hydrogen; 2) introducing hydrogen-3 gas into the cavity; 3) cooling the cavity to allow absorption of hydrogen-3; and 4) measuring the amount of hydrogen-3 by: a) cooling the cavity to about 4.degree. K while flowing a known and regulated amount of inert carrier gas such as argon or helium into the cavity; b) allowing the cavity to warm at a stable rate from 4.degree. K to room temperature as it leaves the chamber; and c) directing the exit gas to an ion chamber radiation detector.

2008-03-11

100

Headspace gas chromatographic method for determination of methyl bromide in food ingredients  

Energy Technology Data Exchange (ETDEWEB)

A headspace gas chromatographic (GC) method, which can be automated, has been developed for determination of methyl bromide. This method has been applied to wheat, flour, cocoa, and peanuts. Samples to be analyzed are placed in headspace sample vials, water is added, and the vials are sealed with Teflon-lined septa. After an appropriate equilibration time at 32 degrees C, the samples are analyzed within 10 h. A sample of the headspace is withdrawn and analyzed on a gas chromatograph equipped with an electron capture detector (ECD). Methyl bromide levels were quantitated by comparison of peak area with a standard. The standard was generated by adding a known amount of methyl bromide to a portion of the matrix being analyzed and which was known to be methyl bromide free. The detection limit of the method was 0.4 ppb. The coefficient of variation (CV) was 6.5% for wheat, 8.3% for flour, 3.3% for cocoa, and 11.6% for peanuts.

1985-11-01

101

Resolution studies of a GEM-based TPC  

Energy Technology Data Exchange (ETDEWEB)

Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons ...

2006-12-15

102

Measurement of 12(S)-hydroxy-5Z,8E,10E-heptadecatrienoic acid and its metabolite 12-oxo-5Z,8E,10E-heptadecatrienoic acid in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry  

International Nuclear Information System (INIS)

Thromboxane A2, the predominant product of arachidonic acid metabolism in the blood platelet, is a potent vasoconstrictor and platelet agonist. During its biosynthesis from cyclic endoperoxide, 12(S)-hydroxy-5Z,8E,10E-heptadecatrienoic acid (HHT) is formed in equal amounts. The further metabolism of HHT, catalyzed by 15-hydroxyprostaglandin dehydrogenase, leads to 12-oxo-5Z,8E,10E-heptadecatrienoic acid (Oxo-HT). Sample workup procedures are described which allow for the sensitive and reproducible determination of these two arachidonic acid metabolites in human plasma by gas chromatography-mass spectrometry in the presence of deuterated analogues as internal standards. HHT is derivatized to the pentafluorobenzyl ester tert-butyldimethylsilyl ether. In order to enable quantification of low concentrations of about 10 pg/ml in nonstimulated human plasma, the samples have to be purified by HPLC. Oxo-HT is derivatized to the pentafluorobenzyl ester, ...

1990-01-01

103

Advanced distillation curve measurements for corrosive fluids: Application to two crude oils  

Energy Technology Data Exchange (ETDEWEB)

We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. The modifications include a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis) and corrosivity assessment of each distillate fraction. The composition-explicit information is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. We have applied the new method to a variety of fluids, including simple n-alkanes, rocket propellant, gasoline, jet fuels, and a hydrocarbon fluid made corrosive with dissolved hydrogen sulfide. In the current contribution, we present the application of the advanced distillation curve method to two samples of crude oil. A primary motivation behind the work is to precisely measure the distillation curves of these oils using our advanced distillation apparatus; these low uncertainty measurements of true ...

2008-10-15

104

Advanced distillation curve measurement: Application to a bio-derived crude oil prepared from swine manure  

Energy Technology Data Exchange (ETDEWEB)

We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. This new method is a significant improvement over current approaches, with features including a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis), trace chemical analysis of each distillate fraction, and a corrosivity assessment of each distillate fraction. In the present contribution, we present the application of the advanced distillation curve method to a bio-derived crude oil prepared from swine manure. One motivation behind the work was to precisely measure the distillation curve of the oil derived from swine manure with our advanced distillation apparatus and compare the bio-derived oil to traditional petroleum crude oils. Then, the information content of the bio-derived oil distillation was extended further with the composition-explicit data channel: gas ...

2008-11-15

105

Performance of a Bragg curve detector for heavy ion identification  

Energy Technology Data Exchange (ETDEWEB)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.

1982-12-15

106

Performance of a Bragg curve detector for heavy ion identification  

International Nuclear Information System (INIS)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).

107

Measurement of dose distributions of linear energy transfer in matter irradiated by fast neutrons  

Energy Technology Data Exchange (ETDEWEB)

A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.

1990-01-01

108

Determination of radon and thoron permeability through some plastics by track technique  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

1986-01-01

112

Light liquid hydrocarbons from the catalytic pyrolysis of sewage sludge lipid  

Energy Technology Data Exchange (ETDEWEB)

The lipid obtained by the toluene extraction of a dried raw Atlanta sewage sludge by the Soxhlet method, was pyrolyzed over activated alumina at atmospheric pressure. A range of weight hourly space velocities (WHSV) from 0.22-1.60/h and a range of temperatures from 400-480[degree]C were selected. A 70 wt % yield of light liquid hydrocarbons was obtained at a WHSV of 0.46/h and 450[degree]C. The sulfur and nitrogen contents of the pyrolysis products were much lower than products from direct liquefaction of sludge. Infrared spectra and [sup 13]C nuclear magnetic resonance confirmed the absence of carbonyl groups in the products. Gas chromatography showed a uniform hydrocarbon chain length distribution across the C[sub 7] to C[sub 17] mass range. The gas product consisted mainly of carbon dioxide and hydrocarbons. Lauric acid was used as a model to study the decarboxylation. The effects of catalyst loading and catalyst ...

1993-01-01

113

Spectrochemical analysis using infrared multichannel detectors  

CERN Document Server

Spectrochemical analysis using infrared multichannel detectors

2007-01-01

114

CZT Detector and HXI Development at CASS/UCSD  

CERN Document Server

CZT Detector and HXI Development at CASS/UCSD

2006-01-01

115

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)  

CERN Document Server

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)

2011-01-01

116

Design, construction and testing of a radon experimental chamber; Diseno, construccion y pruebas de una camara experimental de radon  

Energy Technology Data Exchange (ETDEWEB)

To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact ...

1991-10-15

117

Microcantilever detector for explosives  

Energy Technology Data Exchange (ETDEWEB)

Methods and apparatus for detecting the presence of explosives by analyzing a vapor sample from the suspect vicinity utilize at least one microcantilever. Explosive gas molecules which have been adsorbed onto the microcantilever are subsequently heated to cause combustion. Heat, along with momentum transfer from combustion, causes bending and a transient resonance response of the microcantilever which may be detected by a laser diode which is focused on the microcantilever and a photodetector which detects deflection of the reflected laser beam caused by heat-induced deflection and resonance response of the microcantilever. 2 figs.

1999-06-29

118

FFTF core and primary sodium circuit instrumentation  

International Nuclear Information System (INIS)

Plans, engineering parameters, and some test results for several FFTF core and primary sodium circuit instrument systems are presented. The systems discussed include temperature, flow, pressure, leak detectors, level sensors, fuel failure monitoring, sodium impurity analysis and cover gas monitors. Since many of these instruments are similar to those used in other fast reactors around the world, only a brief description is presented for these systems. Results of recent demonstration tests of the FFTF Under-Sodium Viewing and Ranging system are also presented. (U.K.).

119

Studies on sup(99m)Tc-pertechnetate from the MEK solvent extraction generator  

International Nuclear Information System (INIS)

Analysis by gas chromatography-mass spectrometry and high performance liquid chromatography has revealed organic residues in sup(99m)Tc-pertechnetate obtained from "9"9Mo-molybdate by extraction, using the organic solvent methylethylketone (MEK). The organic residues have been identified as either (i) low molecular weight carbonyl compounds such as formaldehyde, acetaldehyde and acetone, presumably caused by the effects of #gamma#-radiation on MEK, or (ii) condensation products resulting from the action of strong alkali on MEK during the extraction process. The quantities of organic residues varied from batch to batch of extracted pertechnetate; up to 40 #mu# mL"-"1 was found. When these compounds were tested, in rats, by addition to a pyrophosphate bone-seeking radiopharmaceutical, the tissue distribution was not significantly different from that in the control, which contained no added compound. Assay for "9"9Tc in ...

120

Contributions of pesticide residue chemistry to improving food and environmental safety: past and present accomplishments and future challenges.  

Science.gov (United States)

The principles of modern pesticide residue chemistry were articulated in the 1950s. Early authors pointed out the advantages of systematizing and standardizing analytical methods for pesticides so that they could be widely practiced and the results could be reproduced from one laboratory to the next. The availability of improved methods has led to a much more complete understanding of pesticide behavior and fate in foods and the environment. Using methods based largely upon gas chromatography (GC) and high-performance liquid chromatography (HPLC) coupled increasingly with mass spectrometry (MS) and MS(n) as the detection tool, residues can be measured at parts per billion levels and below in a variety of food and environmental matrices. Development of efficient extraction and cleanup methods, techniques such as ELISA, efficient sample preparation techniques such as QuEChERS, and automated laboratory and field ...

2011-04-07

121

Methods and results for calibration and track separation of a GEM based TPC using an UV-laser  

Energy Technology Data Exchange (ETDEWEB)

In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high precision. To guarantee this high precision the detectors have to ...

2008-12-15

122

Studies of basic parameters of electron-counting detection  

International Nuclear Information System (INIS)

Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).

1990-05-21

123

Theoretical study of lithium isotope separation by displacement chromatography  

Energy Technology Data Exchange (ETDEWEB)

Lithium isotope separation by displacement chromatography is studied using fundamental principles; the equations are derived assuming theoretical stages in lithium adsorption bands. The concentration profiles in the band are calculated numerically under unsteady state.

1982-01-01

124

Methylprednisolone acetate induced release of cartilage proteoglycans: determination by high performance liquid chromatography.  

UK PubMed Central (United Kingdom)

A high performance liquid chromatography (HPLC) procedure suitable for the simultaneous determination of the molecular size and concentration of macromolecular hyaluronate and proteoglycans in synovial...Full Text Available

1992-02-01

125

Determination of Salirasib (S-trans, trans-farnesylthiosalicylic acid) in human plasma using liquid chromatography-tandem mass spectrometry  

UK PubMed Central (United Kingdom)

A liquid chromatography/tandem mass spectrometric (LC/MS/MS) assay was developed for the quantitative determination of salirasib (S-trans, trans-farnesylthiosalicylic acid,...Full Text Available

2008-06-15

126

Detection and Identification of Ciprofloxacin-Resistant Yersinia pestis by Denaturing High-Performance Liquid Chromatography  

UK PubMed Central (United Kingdom)

Denaturing high-performance liquid chromatography (DHPLC) has been used extensively to detect genetic variation. We used this method to detect and identify Yersinia pestis KIM5 ciprofloxacin-resistant...Full Text Available

2003-07-01

127

Characterization of a pigment-dispersing hormone in eyestalks of the fiddler crab Uca pugilator  

UK PubMed Central (United Kingdom)

A pigment-dispersing hormone (PDH) from eyestalks of the fiddler crab Uca pugilator has been purified by gel filtration, ion-exchange chromatography, partition chromatography, and reversed-phase...Full Text Available

1985-08-01

128

Anion-exchange extraction of cephapirin, cefotaxime, and cefoxitin from serum for liquid chromatography.  

UK PubMed Central (United Kingdom)

An anion-exchange column technique for extraction of antibiotics from serum proteins has been developed for use in the assay of cephapirin, cefotaxime, and cefoxitin by high-pressure liquid chromatography....Full Text Available

1982-04-01

129

Gasoline from natural gas by sulfur processing. Quarterly technical progress report No. 2, October 1, 1993--December 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

This report presents the work performed at the Institute of Gas Technology (IGT) during the second program quarter from October 1, 1993 to December 31, 1993, under Department of Energy (DOE) Contract No. DE-AC22-93PC92114. This program has co-ordinated funding for Task 1 from IGT`s Sustaining Membership Program (SMP), while DOE is funding Tasks 2--8. Progress in all tasks are reported. The overall objective of this research project is to develop a catalytic process to convert natural gas to liquid transportation fuels. The process consists of two steps that each utilize catalysts and sulfur containing intermediates: (1) to convert natural gas to CS{sub 2} and (2) to convert CS{sub 2} to gasoline range liquids. Experimental data will be generated to demonstrate the potential of catalysts and the overall process. During this quarter, progress in the following areas has been made. An existing unit at IGT was modified to ...

1994-02-01

130

Non-thermal atmospheric pressure HF plasma source: generation of nitric oxide and ozone for bio-medical applications  

International Nuclear Information System (INIS)

A new miniature high-frequency (HF) plasma source intended for bio-medical applications is studied using nitrogen/oxygen mixture at atmospheric pressure. This plasma source can be used as an element of a plasma source array for applications in dermatology and surgery. Nitric oxide and ozone which are produced in this plasma source are well-known agents for proliferation of the cells, inhalation therapy for newborn infants, disinfection of wounds and blood ozonation. Using optical emission spectroscopy, microphotography and numerical simulation, the gas temperature in the active plasma region and plasma parameters (electron density and electron distribution function) are determined for varied nitrogen/oxygen flows. The influence of the gas flows on the plasma conditions is studied. Ozone and nitric oxide concentrations in the effluent of the plasma source are measured using absorption spectroscopy and electro-chemical ...

2010-01-01

131

Volatile Organic Compound Formation in Waste Composting Processes  

Environmental Research Database

Objectives~%~ To quantify the volatile organic compound (VOC) emissions arising from the composting of a range of municipal and~%~ industrial wastes.~%~~%~ To relate the VOC emissions to the material being processed and the process conditions.~%~~%~ To confirm the findings of the above activites by monitoring full-scale composting operations.~%~~%~ To develop predictive models of VOC emissions in relation to waste feedstock and process conditions.~%~~%~ To produce guidance for plant designers, operators a [continued...]DescriptionA recent study of three composting plants undertaken for the Environment Agency has confirmed earlier work suggesting that waste composting can be a source of volatile organic compound (VOC) emissions. However, these experiments were restricted to garden and kitchen waste composting schemes and it was not possible to measure the effect that the process conditions had on the VOC emissions. ...

2005-01-30

132

Survey for N-nitroso compounds at B. F. Goodrich, Woodburn, Indiana, December 12, 1979. Industrywide survey. [N-nitrosomorpholine and N-nitrosodimethylamine  

Energy Technology Data Exchange (ETDEWEB)

Worker exposures to N-nitroso compounds were evaluated at B.F. Goodrich Company, Woodburn, Indiana on December 12, 1979. Personal and area air samples were collected and analyzed by gas-chromatography and thermal-energy-analysis methods. All of the samples contained N-nitrosomorpholine (NMOR) and five samples also contained N-nitrosodimethylamine (NDMA). The amount of NMOR ranged from 0.85 to 3.7 micrograms per cubic meter (micrograms/cu m) for area air samples and 0.63 to 1.8 micrograms/cu m for personal samples. NDMA concentrations ranged from undetectable to 1.8 microgram/cu m for area samples and undetectable to 0.09 micrograms/cu m for personal samples. The authors note that no exposure standards exist for NDMA or NMOR but both are listed as potential human carcinogens. They suggest that the B.F. Goodrich Company characterize nitrosamine exposures at this facility.

1980-02-28

133

Quantitation of acyl migration during lipase-catalyzed acidolysis, and of the regioisomers of structured triacylglycerols formed  

DEFF Research Database (Denmark)

Various MLM-type (M, medium-chain fatty acids; L, long-chain fatty acids) structured triacylglycerols were produced in pilot- or small-scale packed-bed reactors by lipase-catalyzed acidolysis. The incorporation and acyl migration of octanoic acid were measured by gas chromatography and Grignard degradation, and ranged from 39.0 to 48.7% and 0.6 to 9.3%, respectively. Quantitation of triacylglycerol molecular species was performed by ammonia negative ion chemical ionization (NICI) mass spectrometry (MS). The proportion of ACN (acyl carbon number) 34 species that contained one C-18 fatty acid and two C-8:0, in samples analyzed, varied from 12.5 to 23.2%. The selected regioisomers MLM and MML within the ACN 34 species group were quantified by NICI tandem MS (MS/MS) and were in the range of 97.1 to 98.4% and 1.6 to 2.9%, respectively. There was no correlation between the level of acyl migration during lipase-catalyzed esterification and the level ...

2001-01-01

134

Preliminary studies on the detection of irradiated prawns using 2-alkylcyclobutanones  

Energy Technology Data Exchange (ETDEWEB)

The use of ionising radiation for the preservation of food has been under investigation for many years but has yet to receive worldwide acceptance. Although irradiation can be carefully controlled, it is generally accepted that the development of a test or tests for the detection of irradiated food would enhance consumer confidence and might help to enforce labelling regulations. The 2-alkylcyclobutanones are reported to be the only cyclic compounds formed as the products of the radiolysis of saturated and unsaturated triglycerides. The synthesis of 2-dodecylcyclobutanone (DCB) and 2-tetradecylcyclobutanone (TCB), which are formed from palmitic and stearic acid respectively following irradiation, has been carried out and using irradiated chicken meat as the model for a high-lipid containing food, both cyclobutanones have been extracted with hexane and then identified using gas chromatography/mass spectrometry (GC/MS). DCB and TCB have been ...

1996-12-31

135

Immobilization of stationary phases onto chromatographic supports by gamma radiation  

International Nuclear Information System (INIS)

Cobalt-60 gamma radiation has been found to be an effective means of immobilizing stationary phases onto gas and liquid chromatographic supports. The ability of a phase to crosslink was determined to be highly dependent on its chemical structure. Gamma radiation was employed to immobilize Se-30, a methylsilicone, and 216 PS onto Chromosorb WHP for packed column chromatography. The resultant columns exhibited increased thermal stability and a high degree of efficiency. Several blended phases containing varying ratios of Se-30:216 PS were also immobilized onto chromatographic packings. This work was further extended to the immobilization of Se-30 and 216 PS onto fused silica capillaries via gamma radiation. Columns exhibited excellent efficiency and improved thermal stability. An investigation into the role of immobilization of polymeric phases for HPLC was undertaken. Results indicate that gamma radiation can immobilzied polyoctadecylsiloxane ...

136

Evaluation of chicken manure, kenaf, and phanerochaete chrysosporium (white rot fungus) as enhancers of polychlorinated biphenyl biodegradation  

Energy Technology Data Exchange (ETDEWEB)

In this 150-day study, chicken manure, kenaf, and white rot fungus were added to soil microcosms in an attempt to enhance the degradation of polychlorinated biphenyls. The soil was contaminated with commercial PCB mixtures. Dishes were ammended with 5% dry weight chicken manure, 1% dry weight kenaf, and 1% dry weight kenaf plus Phanerochaete chrysosporium inoculant. PCB concentrations were determined at 30 day intervals by soxhlet extraction and gas chromatography analyses. Preliminary results of microbial populations and PCB degradation are presented. At 90 days, the microcosms amended with chicken manure had significantly higher populations of bacteria, fungi, and actinomycetes. However, at 120 days, these soils underwent great reductions in actinomycete and bacterial populations. Through 60 days, the concentration of the PCBs Aroclor 1242 and 1248 had its greatest reduction in the kenaf amended soils. The concentration of Aroclor 1260 either ...

1995-12-31

137

Elimination of organics chemicals in aqueous solutions by gamma radiation processing  

International Nuclear Information System (INIS)

The objective this work was to evaluate the gamma radiation processing for elimination of organic contaminants on industrial wastewater. Standard samples with 17 hydrocarbons (acetophenone, anisole, benzene, chlorobenzene, cyclohexanone, N, N-dimethylaniline, phenol, naphtalene, 1-chloronaphtalene, n-octadecane, p-nitrotoluene, toluene, tetrachloroethane, tetramethylbenzene, n-undecane, m-xylene and o-xylene) was preparated in hexane with total concentration of 1 #mu# g/ #mu# l which was analyzed by gas chromatography. Other sample with the same concentration of these hydrocarbons in acetone was used to contaminate water samples, which were irradiated with gamma radiation from Co-60 between doses 5.0 to 20.0 KGy and dose rate of 1.162 KGy/h. The activity of source was 1470 Ci. Percents destruction of hydrocarbons were: 79.76 % to 5.0 KGy, 85.97 % to 7.5 KGy, 86.24 % to 10.0 KGy, 86.72 % to 12.5 KGy, 88.92 % to 15.0 KGy, 91.74 % to 17.5 KGy and ...

1992-08-16

138

Effects of ionizing radiation on properties of monolayer and multilayer flexible food packaging materials  

International Nuclear Information System (INIS)

Volatile compounds produced in flexible food packaging materials (LDPE, EVAc, PET/PE/EVOH/PE) during electron beam irradiation were isolated by purge and trap technique and identified by combined gas chromatography-mass spectrometry (GC/MS), after thermal desorption and concentration. For comparison purposes non-irradiated films were also studied. Film samples were irradiated at low (5 kGy, corresponding to cold pasteurization), intermediate (20 kGy, corresponding to cold sterilization) and high (100 kGy) doses. It was observed that a number of volatile compounds are produced after irradiation in all cases. Furthermore the amounts of all volatile compounds increase with increasing irradiation dose. Both primary (methyl-derivatives etc.) as well as secondary i.e. oxidation products (ketones, aldehydes, alcohols, carboxylic acids etc.) are produced upon irradiation. These products may affect organoleptic properties and thus shelf-life of ...

1999-05-01

139

Determination of the surface properties calcite treated with stearic acid by Inverse Gas Chromatography  

Energy Technology Data Exchange (ETDEWEB)

The values of -{delta}G{sub A}{sup O} of n-alkanes on calcite are lower on the stearic acid treated calcite than on the untreated calcite. The value of -{delta}G{sub A}{sup O} of n-alkanes on calcite increase with increasing carbon numbers of n-alkanes. The values of -{delta}G{sub A}{sup O} measured on the treated calcite are significantly lower than those measured on the untreated calcite. The -{delta}G{sub A}{sup O} of n-alkanes on the treated calcite are close to the heat of liquefaction of n-alkanes. All the experimental values of -{delta}G{sub A}{sup O} of n-alkanes on calcite are larger than theoretical entropy decrease particularly for the higher molecular mass n-alkanes. Thus the important entropy decrease observed upon adsorption can not only be attributed to the loss of one degree of freedom of the adsorbed molecules. The values of {gamma}{sub S}{sup D} of the treated and untreated calcite decrease with increasing temperature. {gamma}{sub S}{sup D} for the treated calcite is ...

1999-10-31

140

Determination of microsomal lauric acid hydroxylase activity by HPLC with flow-through radiochemical quantitation  

International Nuclear Information System (INIS)

An assay for the microsomal hydroxylation of lauric acid (LA), based on HPLC with flow-through radiochemical detection, has been developed. Conditions were optimized for resolution and quantitation of three microsomal metabolites of "1"4C-LA, one of which has not been reported previously as a metabolite of LA in mammalian microsomal incubations. These products, 12-(omega)-hydroxy-LA, 11-(omega-1)-hydroxy-LA, and a novel metabolite, 10-(omega-2)-hydroxy-LA, were isolated by HPLC and identified by gas chromatography/mass spectrometry. In the presence of NADPH, the formation of all three metabolites was linear with time and microsomal protein concentration. Hydrogen peroxide also supported the microsomal metabolism of LA, although the ratio of metabolites was substantially different than that produced by NADPH-supported microsomes. Several biochemical probes (metyrapone, #alpha#-naphthoflavone, 2-diethylaminoethyl-2,2-diphenylvalerate ...

141

Black tide from the Bay of Campeche. [June 3, 1976 blowout  

Energy Technology Data Exchange (ETDEWEB)

The ruptured offshore oil well 80 miles from Mexican town of Ciudad del Carmen, which poured 8000 barrels of light oil a day into the Gulf of Mexico, provided marine scientists with the opportunity to monitor the spill and see what happens to petroleum hydrocarbons in sea water. Scientists followed changes in viscosity, surface tension, and buoyancy of individual oil globs as they moved through the water and interacted with the surface slick. Using gas chromatography and mass spectroscopy, chemists are gaining an understanding of the unique characteristics of the oil. Computer-generated models projected the slick's movement in the Gulf in response to wind and wave pressures, but the sophisticated system did not give an accurate daily prediction. Immediate damage to fish, turtles, and sea birds was documented by tagging. Long-term effects will take longer to ascertain since 25 years is generally required to flush oil out of sediments. ...

1980-01-24

142

Bioremediation process in impacted area of petroleum activities; Processos de biorremediacao em areas influenciadas por atividades petroliferas  

Energy Technology Data Exchange (ETDEWEB)

The present work's objective is to test sampling methodologies applied on the bioremediation processes in situ, involving the establishment of sample replicates, specific laboratory procedures and its results, inedited on the referred technique. Agricultural fertilizers were used, NPK and OSMOCOTE, as biostimulants on mangroves substrates affected by petroleum activities. The tested methodology used on the experiment was based on the monitoring of this technology in aquarium with water from Sao Paulo's river and sediment contaminated by oil, realized in three steps (first pre-test, second pre-test and third pre-test) that happened between the months of August and November of 2007. The physical-chemical parameters were measured with portable devices carefully calibrated and the oil analyzed with gas chromatography. The saturated hydrocarbons (n-alkenes) had an increase on the concentrations for some aquariums and these found ...

2008-07-01

143

Antioxidant properties of natural substances in irradiated fresh poultry  

Energy Technology Data Exchange (ETDEWEB)

This study was undertaken to determine if a combined treatment (marinating in natural plant extracts or vacuum) with irradiation could have a synergistic effect, in order to prevent the lipid oxidation resulting in the development of undesirable flavours. The fresh chicken legs were irradiated at 0,3 and 5 kGy. The fatty acids composition of lipids was identified using gas liquid chromatography. The effect of irradiation treatment combined with a pre-treatment on the fatty acids composition was followed. The day after irradiation, ten panallists were asked to evaluate, using the instruction scaling, the overall appearance, the odor, the flavor and the overall acceptability of the samples. The major fatty acids identified in lipids were oleic acid, palmitic acid, palmitoleic acid and stearic acid. Pre-treatments have a significant effect on linoleic acid (C18:2) and higher fatty acids. The unsaturated fatty acids derived from phospholipids ...

1998-06-01

144

Accumulation levels and characteristics of some pesticides in human adipose tissue samples from Southeast China  

British Library Electronic Table of Contents (United Kingdom)

This paper presents a comprehensive study of pesticide levels and bio-accumulation characteristics in human adipose tissues among residents of Southeast China. A large number of adipose samples (n=633) were selected for 58 pesticides and were analyzed by high sensitive Gas Chromatography-Tandem Mass Spectrometry (GC-MS/MS). The results showed that POPs pesticides were frequently detected, including 2,4prime-DDD, 2,4prime-DDE, 2,4prime-DDT, 4,4prime-DDD, 4,4prime-DDE, 4,4prime-DDT, a-HCH, b-HCH, g-HCH, d-HCH, hexachlorobenzene (HCB), and mirex. Other detected pesticide species were dicofol, methamidophos and chlordimeform, which have rarely been reported. Comparing to different countries, the concentrations of total DDT and HCH in these three Chinese southeastern sites were in the middle ra...

2011-01-01

145

A new porous-layer activated-charcoal-coated fused silica fiber: application for determination of BTEX compounds in water samples using headspace solid-phase microextraction and capillary gas chromatography  

Energy Technology Data Exchange (ETDEWEB)

Extra-fine powdered activated charcoal has been used as stationary phase (coating layer) in solid-phase microextraction (SPME). The efficiency and reliability of the prepared device have been investigated for the extraction of some volatile organic compounds such as benzene, toluene, ethylbenzene and xylene isomers (BTEX) from the headspace of water samples. Monitoring of the extracted compounds and further quantitative analysis of the real samples have been performed by capillary GC-FID. Effects of several factors such as temperature, addition of salt, and stirring speed on extraction efficiency and exposure time have been studied. Under optimum conditions, extraction recoveries for these compounds from 50 mL water were >95%. The calibration graphs were linear in the range 5 to 10{sup 4} pg mL{sup -1} and the detection limit for each BTEX compound was 1.5-2 pg mL{sup -1}. The results obtained by use of this porous layer activated charcoal (PLAC)-coated fiber have also been compared ...

1997-12-31

146

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm without implementing vacuum ...

1995-10-01

147

Type tests to the automatic thermoluminescent dosimetry system acquired by the CPHR for personal dosimetry; Pruebas tipo al sistema de dosimetria termoluminiscente automatico adquirido por el CPHR para dosimetria personal  

Energy Technology Data Exchange (ETDEWEB)

The CPHR individual monitoring service acquired an automatic RADOS TLD system to improve its capacities to satisfy the increasing needs of their national customers. The TLD system consists of: two automatic TLD reader, model DOSACUS, a TLD irradiator and personal dosimeters card including slide and holders. The dosimeters were composed by this personal dosimeters card and LiF:Mg,Cu,P (model GR-200) detectors. These readers provide to detectors a constant temperature readout cycle using hot nitrogen gas. In order to evaluate the performance characteristics of the system, different performance tests recommended by the IEC 1066 standard were carried out. Important dosimetric characteristics evaluated were batch homogeneity, reproducibility, detection threshold, energy dependence, residual signal and fading. The results of the tests showed good performance characteristics of the system. (Author)

2006-07-01

148

Position sensitive and Bragg curve spectroscopy detector system  

Energy Technology Data Exchange (ETDEWEB)

A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/..delta..Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/..delta..Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane coordinate within +-0.5 mm.

1984-08-01

149

Position sensitive and Bragg curve spectroscopy detector system  

International Nuclear Information System (INIS)

A heavy ion gas detector system consisting of a Bragg-curve spectroscopy ionization chamber for particle identification and a multiwire proportional chamber as position sensitive fast trigger device is described. The Bragg IC has been tested with several beams up to Z=36 to investigate some aspects of the BCS method. Results are reported on energy resolution and linearity, Z resolving power and mass sensitivity. The energy resolution is well below 1%. The Bragg-peak amplitude is fairly independent of the energy in a wide energy range and single elements are identified up to Z=38 with a resolving power Z/#DELTA#Zproportional50-80. Isotope identification by range measurement is limited by the straggling in the ionization process and the mass resolving power is M/#DELTA#Mproportional20-26 for S and Si isotopes. The MWPC allows subnanosecond time resolution and position identification along the in-plane coordinate within +-0.5 mm. (orig.).

150
151

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

157

Small world when building a particle detector prototype, the devil is in the tiny details  

CERN Multimedia

Small world when building a particle detector prototype, the devil is in the tiny details

2004-01-01

158

Photodiode Scintillation Detector for Anti-Coincidence Shielding  

Science.gov (United States)

Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...

159

Development of a method for xenon determination in the microstructure of high burn-up nuclear fuel[Dissertation 17527  

Energy Technology Data Exchange (ETDEWEB)

In nuclear fuel, in approximately one quarter of the fissions, one of the two formed fission products is gaseous. These are mainly the noble gases xenon and krypton with isotopes of xenon contributing up to 90% of the product gases. These noble fission gases do not combine with other species, and have a low solubility in the normally used uranium oxide matrix. They can be dissolved in the fuel matrix or precipitate in nanometer-sized bubbles within the fuel grain, in micrometer-sized bubbles at the grain boundaries, and a fraction also precipitates in fuel pores, coming from fuel fabrication. A fraction of the gas can also be released into the plenum of the fuel rod. With increasing fission, and therefore burn-up, the ceramic fuel material experiences a transformation of its structure in the 'cooler' rim region of the fuel. A subdivision occurs of the original fuel grains of few microns size into thousands of small grains of sub-micron sizes. ...

2008-07-01

160

Radon concentration measurements in bituminous coal mines  

Energy Technology Data Exchange (ETDEWEB)

Radon measurements were carried out in Kozlu, Karadon and Uzulmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) in the study area. The radon concentration measurements were performed on a total of 42 points in those three mines. The annual exposure, the annual effective dose and lifetime fatality risk, which are the important parameters for the health of workers, were estimated based on chronic occupational exposure to the radon gas, which is calculated using UNCEAR-2000 and ICRP-65 models. The radon concentrations at several coal production faces are higher than the action level of 1000 Bq m{sup -3}. It is suggested that the ventilation rates should be rearranged to reduce the radon concentration.

2005-07-01

161

Radon as a tracer of fluids motion in karstic aquifers; Le radon: traceur des circulations fluides dans les aquiferes karstiques  

Energy Technology Data Exchange (ETDEWEB)

Radon ({sup 222}Rn) is a naturally occurring radioactive gas and can be used as a tracer in hydrogeologic studies. Radon concentration measurements have been achieved in ground-air and in groundwater by means of nuclear track detectors to estimate long-term variations. Continuous measurements have been conducted using an electronic automatic probe, to evaluate short-term variations. The results obtained from bore-holes show a good correlation between the aquifer`s structural characteristics and the radon concentrations. The continuous measurements specify rainfall influence. (author). 10 refs., 7 figs., 2 tabs.

1995-04-01

162

Furnace for rapid change of temperature for neutron diffraction  

International Nuclear Information System (INIS)

A new furnace for neutron diffraction experiments is capable of heating and cooling a sample very rapidly. The rapid heating is done by two circular infrared lamps placed over and under a sample, whose radiation is roughly focused on the sample by a reflector. The rapid cooling is done by high-pressure gas blows against the sample from two circular nozzles which are also placed over and under the sample. This system enables us to obtain the heating rate of over 1000"0C/min and cooling rate of -500"0C/min for an alloy of 10 mm diameter and 30 mm length. The performance is sufficient to carry out some kinetics measurements in real-time neutron diffraction by the use of a position-sensitive detector. This kind of experiment is demonstrated by the observation of the relaxation process of order--disorder transitions in CuZn and Ni_3Mn alloys.

163

Bragg curve spectroscopy of fission fragments by using parallel plate avalanche counters  

Energy Technology Data Exchange (ETDEWEB)

By using a charge-sensitive preamplifier and methods of energy spectroscopy we investigated the response of a parallel plate avalanche counter in order to scan the Bragg curve. The detector was operated in butane, pentane and heptane which also served as stopping gases. In this paper, we report on results obtained with fission fragments from a /sup 252/Cf source. We achieved a separation of the light and heavy fragment groups in the interval of gas absorber thickness from about 500 ..mu..g cm/sup 2/ to 1.5 mg cm/sup 2/. The best energy loss resolution was achieved with pentane at E/papprox.=70 V cm/sup 1/ Torr/sup 1/ resulting in delta..delta..E/..delta..Eapprox.=13%. The corresponding shape of the ..delta..E spectrum reproduces correctly the nuclear charge distribution of the fragments. (orig.).

1985-07-01

164

A VUV prism spectrometer for RICH radiator refractometry  

CERN Document Server

A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).

2000-01-01

165

Purification and analysis of RNA polymerase II transcription factors by using wheat germ agglutinin affinity chromatography.  

Science.gov (United States)

We recently found that many RNA polymerase II transcription factors are modified with N-acetylglucosamine residues. These sugar moieties confer upon transcription factors an ability to bind the lectin wheat germ agglutinin. We have taken advantage of this interaction to devise a purification procedure for the "GC-box" binding transcription factor Sp1. Crude nuclear extracts are first subjected to wheat germ agglutinin affinity chromatography and then subjected to sequence-specific DNA affinity chromatography. The Sp1 protein purified by this procedure is at least 95% pure, and the overall recovery is greater than 80%. In addition to yielding larger quantities of Sp1 than conventional schemes, the new purification procedure is also simpler and more rapid. We show that wheat germ agglutinin affinity chromatography can also be used to purify the glycosylated forms of the CCAAT-binding transcription factor. Thus, wheat germ ...

1989-03-01

166

Radon generation and transport in and around a gold mine tailings dam in South Africa  

Energy Technology Data Exchange (ETDEWEB)

Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the M.E.D.U.S.A. system. Radon soil ...

2006-07-01

167

Dynamic behaviors of sulfur evolved in the gas phase from pyrolysis of six Chinese coals  

Energy Technology Data Exchange (ETDEWEB)

Dynamic behaviors of gaseous sulfur-containing compounds evolved from pyrolysis of six Chinese coals were studied in the temperature range of up to 800{sup o}C under N{sub 2} and H{sub 2}. The released amount of total sulfur-containing gases was traced by an online flame photometric detector (FPD). Simultaneously, the changes of different sulfur forms, including H{sub 2}S, SO{sub 2}, COS and CS{sub 2}, also were investigated using an online mass spectrometer (MS). FPD results show that the effect of H{sub 2} on gaseous sulfur evolved is complex, which promoted certain peak and suppresses other peaks. Based on the data from MS, it is suggested that a series of competitive reactions between active sulfur and other active matters during pyrolysis may impact on the sulfur form in gas phase. Interactions between active sulfur-containing intermediates and the coal matrix are attributed to be the main factor determining the dynamic behavior.

2006-07-01

168

Determination of radon-222 concentration in inside environments of the Instituto de Engenharia Nuclear, Brazil; Determinacao da concentracao de radonio-222 nos ambientes internos das instalacoes do Instituto de Engenharia Nuclear  

Energy Technology Data Exchange (ETDEWEB)

The gotten concentrations of radon-222 in the installations of the IEN had been determined using the active and passive methods. The active method consisted on the use of the alpha spectrometry with a portable equipment Tracerlab Instruments WLM- Plus. In the determination for the passive method, one used detectors of nuclear strokes of type LEXAN. The raised values had been gotten in the wastes deposit and its annexes, room of the press and laboratory of wastes handling. It was observed, in this sector, an instantaneous measure of alpha spectrometry, concentrations around 1000 Bq.m-3, which had over all to the function of storage, the sector, a great volume of natural radioactive materials, especially of radium-226. This determination was carried through in an extreme situation of ventilation zero, where the gates had been kept closed during the execution of the same one. It was observed, however, a considerable fall, with values ten times inferior, after to ...

2000-07-01

169

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

170

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

171

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

172

Effect of resin size on HETP in separation of isotopes by chromatography  

Energy Technology Data Exchange (ETDEWEB)

In this report, the quantitative relation between the height equivalent to a theoretical plate (HETP) and the size of ion exchange resin is studied by enriching lithium isotopes with high pressure ion exchange displacement chromatography. The dependence of HETP on the size of the resin can be expressed as H = C x (anti r)sup( ) in which = 2.4 and it is found that Snyder's equation is suitable for such a system of isotope separation as may be explained by the simple displacement mechanism.

1985-02-01

173

Comparison Between Active and Passive Techniques for Radon Gas and Working Level measurements, El-Allouga Mine, Sinai, Egypt  

International Nuclear Information System (INIS)

Two different techniques were used for measuring Rn-gas concentrations and Working Level (WL) in U-exploration galleries at El-Allouga Mine, Sinai, Egypt. The active techniques used EDA(RDA-200) with calibrated Lucas cell and Tri-Met-372 instruments and passive techniques used four different types of SSNTD. Twenty eight (28) stations inside the studied tunnels were located covering the different environmental conditions. The measurements were carried out during summer time, in the ventilated sector (16 stations), the average tunnel air temperature was 24.4 #+-# 2.2 degree C and relative humidity 38%. In the non-ventilated sector (12 stations), the average tunnel air temperature was 22.2#+-#0.4 degree C and relative humidity 70%. The Rn-gas concentrations using EDA(RDA-200) and calibrated Lucas cell, in the ventilated sector averaged 11.966 p Ci/l, while in the non-ventilated stations averaged 786.21 p Ci/l. Also for the Tisvoglu method, the ...

2007-04-22

174

The greenhouse gases N{sub 2}O, CH{sub 4} and CO{sub 2} in coniferous forest soils as influenced by nitrogen input, acidity, moisture and temperature; Drivhusgassene N{sub 2}O, CH{sub 4} og CO{sub 2} i barskogsjord under paavirking av N-tilfoersel, surhet, fuktighet og temperatur  

Energy Technology Data Exchange (ETDEWEB)

The thesis relates to an investigation done on greenhouse gases in coniferous forest soils. The production of nitrous oxide (N{sub 2}O) and carbon dioxide (CO{sub 2}), and the consumption of methane (CH{sub 4}) in a temperate forest soil were studied by a rapid and sensitive gas chromatographic (GC) method for analysing all three greenhouse gases at or below ambient levels. Gas fluxes were measured in soil incubation and lysimeter experiments. 15 soil samples were taken at random within a 100 m{sup 2} area in a Norway spruce forest stand (Picea abies). The fluxes of N{sub 2}O, CH{sub 4} and CO{sub 2} were measured under standardized laboratory incubation conditions to investigate spatial variability in relation to other factors such as nitrogen (N) mineralization rate, nitrification rate, organic carbon (OC), total N and pH. The effects of temperature, soil moisture content, and ammonium addition were also studied in an incubation experiment. A ...

1994-07-01

175

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

Energy Technology Data Exchange (ETDEWEB)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. Gamma dose rate varies from 92 to 316nGyh{sup -1}, ...

2007-11-15

176

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

International Nuclear Information System (INIS)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate varies from 92 to 316nGyh"-"1, with an average of 132nGyh"-"1. ...

2007-11-01

177

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

178

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.

2008-10-01

179

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

180

First results from the Lund NMP particle detector system  

International Nuclear Information System (INIS)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-06-15

181

First results from the Lund NMP particle detector system  

British Library Electronic Table of Contents (United Kingdom)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-01-01

182

Toxicity of ultraviolet-irradiated halothane in mice  

Energy Technology Data Exchange (ETDEWEB)

One such agent is the widely used anesthetic, halothane. To study the toxicity of u.v. decomposed halothane, mice were exposed to anesthetic concentrations (1.3%) of non- and u.v.-irradiated halothane in oxygen for 90 min. Halothane sleeping times increased from 14.3 min to 72.5 min. Microsomal mixed function oxidase activity decreased, as shown by prolonged pentobarbital sleeping times 1 day after exposure to halothane and irradiated halothane (54.6 min and 149.1 min, respectively, as compared to a 34.6-min control). Quantitative and qualitative differences were found in the amount of (/sup 14/C)-pentobarbital metabolites excreted by u.v. irradiated halothane-exposed mice compared to either oxygen or non-irradiated halothane-exposed groups. In addition, serum glutamic-oxalacetic transaminase (SGOT) of irradiated halothane-exposed mice increased to 233% of the control values, and serum glutamic-pyruvic transaminase (SGPT) were 377% of control values. No significant changes in SGOT or ...

1982-01-01

183

Separation of recycling and reserve synaptic vesicles from cholinergic nerve terminals of the myenteric plexus of guinea pig ileum.  

Science.gov (United States)

Acetylcholine-rich synaptic vesicles were isolated from myenteric plexus-longitudinal muscle strips derived from the guinea pig ileum by the method of Dowe, Kilbinger, and Whittaker [J. Neurochem. 35, 993-1003 (1980)] using either unstimulated preparations or preparations field-stimulated at 1 Hz for 10 min using pulses of 1 ms duration and 10 V . cm-1 intensity. The organ bath contained either tetradeuterated (d4) choline (50 microM) or [3H]acetate (2 muCi . ml-1); d4 acetylcholine was measured by gas chromatography-mass spectrometry. As with Torpedo electromotor cholinergic vesicle preparations made under similar conditions the distribution of newly synthesized (d4 or [3H]) acetylcholine in the zonal gradient from stimulated preparations was not identical with that of endogenous (d0, [1H]) acetylcholine, but corresponded to a subpopulation of denser vesicles (equivalent to the VP2 fraction from Torpedo) that had preferentially taken up newly ...

1985-01-01

184

Monitoring, sampling and analysis of fine particulates -- Results and experiences from DOE's Federal Energy Technology Center  

Energy Technology Data Exchange (ETDEWEB)

The overall goal of the DOE fine particulate program is to ensure that the best science and technology is available for any regulatory decision-making related to the health and environmental impacts of ambient fine particulate matter and regional haze. Interest primarily lies in the particulate fraction having aerodynamic diameters of 2.5 microns and less (PM2.5). Particulates of this size are the focus of the newly established National Ambient Air Quality Standards. As such, the Federal Energy Technology Center (FETC) is establishing a fine particulate sampling station at the Center's Pittsburgh site located in South Park Township, PA. This sampling station is one of a group of stations scattered throughout Pennsylvania, West Virginia, and Ohio that constitute the Upper Ohio River Valley Project. The station is equipped with a full complement of fine particulate and gaseous monitors including the following: (1) R and P Sequential FRM sampler, (2) Grimm PM2.5 continuous ...

1999-07-01

185

Development on the technologies for tritium removal processes  

Energy Technology Data Exchange (ETDEWEB)

While tritium exposure to the site-workers in Wolsung NPP is upto about 40 % of the total personnel exposure, Korea Institute of Nuclear Safety has asked tritium removal facility, as one of the requirements for post reactor construction, after operation of four CANDU reactors in Wolsung site. For the purpose of essential removal of tritium from the heavy water system of the heavy water reactors, an experiment of Ar-N{sub 2} cryogenic distillation tower was carried out as a preliminary study for development of liquid-phase catalytic exchange - cryogenic hydrogen distillation process. The steady-state reached after 50 minutes under 90 K in the Ar-N{sub 2} distillation column (inner diameter 20 mm, height 500 mm) packed with Dixon ring ({phi} 3 mm x H 3 mm), and the ratios of Ar-concentration at the top and at the bottom measured by gas chromatography within {+-}1 % relative error was approximately 93 : 3. This value was distillation performances ...

1994-12-01

186

Development on the cryogenic hydrogen isotopes distillation process technology for tritium removal (Final report)  

Energy Technology Data Exchange (ETDEWEB)

While tritium exposure to the site-workers in Wolsung NPP is up to about 40% of the total personnel exposure, Ministry of Science and Technology has asked tritium removal facility for requirement of post heavy-water reactor construction. For the purpose of essential removal of tritium from the Wolsung heavy-water reactor system, a preliminary study on the cryogenic Ar-N{sub 2} and H{sub 2}-D{sub 2} distillation process for development of liquid-phase catalytic exchange cryogenic hydrogen distillation process technology. The Ar-N{sub 2} distillation column showed good performance with approximately 97% of final Ar concentration, and a computer simulation code was modified using these data. A simulation code developed for cryogenic hydrogen isotopes (H{sub 2}, HD, D{sub 2}, HT, DT, T{sub 2}) distillation column showed good performance after comparison with the result of a JAERI code, and a H{sub 2}-D{sub 2} distillation column was made. Gas ...

1995-12-01

187

Development of a stable cobalt-ruthenium Fischer-Tropsch catalyst. Technical progress report No. 12, July 1, 1992--September 30, 1992  

Energy Technology Data Exchange (ETDEWEB)

The fixed bed pilot plant, the catalyst testing procedure, and the calculations for conversion and selectivities were previously described in the technical progress report covering the period of 3/16/88 to 6/16/88 for Contract DE-AC22-87PC79812. Conversions and hydrocarbon selectivities were calculated using data from an on-line gas chromatography (GC) analyzer. Alcohol selectivities were calculated using data from an on-line boiling point GC analyzer which analyzed the liquid product. The catalysts were prepared via the steps of impregnation, calcination, and reduction on a special Y-zeolite-derived support. The impregnation step consisted of evaporation of metal salts on to the support from an aqueous solution. For one catalyst (No. 6531-188) the metal salts were evaporated on to the support from a reverse micelle solution containing the metal salts. All the catalysts were calcined for four hours at 450{degree}C. The calcined catalysts were ...

1992-12-31

188

Cysteinyl peptides of rabbit muscle pyruvate kinase labeled by the affinity label 8-((4-bromo-2,3-dioxobutyl)thio)adenosine 5 prime -triphosphate  

Energy Technology Data Exchange (ETDEWEB)

The affinity label 8-((4-bromo-2,3-dioxobutyl)thio)adenosine 5{prime}-triphosphate (8-BDB-TA-5{prime}-TP) reacts covalently with rabbit muscle pyruvate kinase, incorporating 2 mol of reagent/mol of enzyme subunit upon complete inactivation. Protection against inactivation is provided by phosphoenolpyruvate, K{sup +}, and Mn{sup 2+} and only 1 mol of reagent/mol of subunit is incorporated. The authors have now identified the resultant modified residues. After reaction with 8-BDB-TA-5{prime}-TP at pH 7.0, modified enzyme was incubated with ({sup 3}H)NaBH{sub 4} to reduce the carbonyl groups of enzyme-bound 8-BDB-TA-5{prime}-TP and to introduce a radioactive tracer into the modified residues. Following carboxymethylation and digestion with trypsin, the radioactive peptides were separated on a phenylboronate agarose column followed by reverse-phase high-performance liquid chromatography in 0.1% trifluoroacetic acid with an acetonitrile gradient. ...

1990-03-13

189

Chemistry of transuranium elements and compounds  

International Nuclear Information System (INIS)

Studies are made in this program to enhance our understanding of the role of 5f electrons in chemical bonding. Most of our studies on the macroscopic scale emphasize certain isotopes available from the National Transplutonium Production Program centered at HFIR/TRU -namely, _9_6"2"4"8Cm, _9_7"2"4"9Bk, _9_8"2"4"9Cf, _9_9"2"5"3Es, and _9_9"2"5"4Es. Particular classes of compounds, such as hydrides, chalcogenides, and pnictides are often selected for study on the basis of their utility in bringing out significant chemical differences between the lanthanides and the actinides. High temperature/high pressure experiments on actinide metals and compounds reveal characteristics about the degree of 5f electron localization as a function of atomic number in the series. Magnetic properties of metals and compounds are investigated using ultra-sensitive methods and hydration numbers of ions in solution are investigated by neutron scattering at HFIR. As a result of a recently renewed ...

1986-05-01

190

An in vitro model to test relative antioxidant potential: Ultraviolet-induced lipid peroxidation in liposomes  

International Nuclear Information System (INIS)

Since antioxidants have been shown to play a major role in preventing some of the effects of aging and photoaging in skin, it is important to study this phenomenon in a controlled manner. This was accomplished by developing a simple and reliable in vitro technique to assay antioxidant efficacy. Inhibition of peroxidation by antioxidants was used as a measure of relative antioxidant potential. Liposomes, high in polyunsaturated fatty acids (PUFA), were dispersed in buffer and irradiated with ultraviolet (UV) light. Irradiated liposomes exhibited a significantly higher amount of hydroperoxides than liposomes containing antioxidants in a dose- and concentration-dependent manner. Lipid peroxidation was determined spectrophotometrically by an increase in thiobarbituric acid reacting substances. To further substantiate the production of lipid peroxides, gas chromatography was used to measure a decrease in PUFA substrate. In order of decreasing ...

191

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

192

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector  

CERN Document Server

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector

1993-01-01

193

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

194

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The ...

2003-03-04

195

AIRBORNE, OPTICAL REMOTE SENSING OF METHANE AND ETHANE FOR NATURAL GAS PIPELINE LEAK DETECTION  

Energy Technology Data Exchange (ETDEWEB)

Ophir Corporation was awarded a contract by the U. S. Department of Energy, National Energy Technology Laboratory under the Project Title ''Airborne, Optical Remote Sensing of Methane and Ethane for Natural Gas Pipeline Leak Detection'' on October 14, 2002. This second six-month technical report summarizes the progress made towards defining, designing, and developing the hardware and software segments of the airborne, optical remote methane and ethane sensor. The most challenging task to date has been to identify a vendor capable of designing and developing a light source with the appropriate output wavelength and power. This report will document the work that has been done to identify design requirements, and potential vendors for the light source. Significant progress has also been made in characterizing the amount of light return available from a remote target at various distances from the light source. A great deal of time ...

2003-11-12

196

Separation of lead-203 from cyclotron-bombarded thallium targets by ion-exchange chromatography  

Energy Technology Data Exchange (ETDEWEB)

A simple method is presented for the separation of lead-203 from copper-backed thallium cyclotron targets. The procedure involves cation-exchange chromatography in hydrochloric acid and hydrochloric acid-acetone mixtures. Further purification involves anion-exchange chromatography in nitric acid-hydrobromic acid mixtures. A cation-exchange column containing 3.0 g of resin can handle as much as 15 g of thallium and 160 mg of copper. An anion-exchange column containing 3.0 g of resin can separate lead from up to 200 mg of thallium and 10 mg of copper. Separations are extremely sharp and less than 0.1 ..mu..g of thallium and less than 0.1 ..mu..g of copper remain in the lead-203 fraction.

1982-07-01

197

Separation of lead-203 from cyclotron-bombarded thallium targets by ion-exchange chromatography  

International Nuclear Information System (INIS)

A simple method is presented for the separation of lead-203 from copper-backed thallium cyclotron targets. The procedure involves cation-exchange chromatography in hydrochloric acid and hydrochloric acid-acetone mixtures. Further purification involves anion-exchange chromatography in nitric acid-hydrobromic acid mixtures. A cation-exchange column containing 3.0 g of resin can handle as much as 15 g of thallium and 160 mg of copper. An anion-exchange column containing 3.0 g of resin can separate lead from up to 200 mg of thallium and 10 mg of copper. Separations are extremely sharp and less than 0.1 #mu#g of thallium and less than 0.1 #mu#g of copper remain in the lead-203 fraction. (author).

198

Irradiation of human insulin in aqueous solution, first step towards radiosterilization  

British Library Electronic Table of Contents (United Kingdom)

The degradation of irradiated human insulin in aqueous solutions was investigated in order to protect the protein against ionizing radiation. The influence of the drug concentration, excipients and irradiation temperature were studied.Aqueous solutions at pH 2 were irradiated by gamma rays or by accelerated electrons. Two different high-performance liquid chromatography (HPLC) methods were used: reverse-phase high-performance liquid chromatography (RP-HPLC)/UV and size exclusion liquid chromatography (SEC/UV) to investigate both the fragmentation and the formation of higher molecular weight proteins.In solution without excipients irradiated at ambient temperature at 10kGy, the loss of human insulin is almost complete. Addition of radio-protecting excipients (free radicals scavengers) and c...

2007-01-01

199

A novel method of single step hydrophobic interaction chromatography for the purification of phycocyanin from Phormidium fragile and its characterization for antioxidant property  

British Library Electronic Table of Contents (United Kingdom)

Phycocyanin - a major phycobiliprotein constitutively produced by many cyanobacteria hold several promising applications in diagnostics, biomedical research, and therapeutics. This paper discusses a novel rapid method for the purification of cyanobacterial phycocyanin (C-PC) from Phormidium fragile using hydrophobic interaction chromatography. The protein was extracted and concentrated by grinding under liquid nitrogen and ammonium sulfate fractionation. C-PC was purified by single step hydrophobic interaction chromatography. Purified phycocyanin showed absorbance maximum (lmax) at 624nm. The criterion of purity (R) achieved was 4.52. Phycocyanin to phycoerythrin and phycocyanin to allophycocyanin purity ratio were 3.85 and 7.49, respectively. The purified protein showed a pI of 5.2 and ha...

2008-01-01

200

A high-performance liquid chromatography-based radiometric assay for sucrose-phosphate synthase and other UDP-glucose requiring enzymes  

Energy Technology Data Exchange (ETDEWEB)

A method for product analysis that eliminates a problematic step in the radiometric sucrose-phosphate synthase assay is described. The method uses chromatography on a boronate-derivatized high-performance liquid chromatography column to separate the labeled product, (14C)sucrose phosphate, from unreacted uridine 5{prime}-diphosphate-(14C)glucose (UDP-Glc). Direct separation of these compounds eliminates the need for treatment of the reaction mixtures with alkaline phosphatase, thereby avoiding the problem of high background caused by contaminating phosphodiesterase activity in alkaline phosphatase preparations. The method presented in this paper can be applied to many UDP-Glc requiring enzymes; here the authors show its use for determining the activities of sucrose-phosphate synthase, sucrose synthase, and uridine diphosphate-glucose pyrophosphorylase in plant extracts.

1991-05-01

201

Gas chromatographic detection of organometallic compounds by reactive-flow photometry  

International Nuclear Information System (INIS)

The response of the reactive flow detector (RFD) toward organometallic compounds of several transition metals has been explored, and several of its strong elemental responses have been characterized in detail. The RFDs minimum detectable flow (measured in picograms of metal per second at S/N_p_-_t_-_p=2) is 0.1 for ruthenium, 3 for chromium, 10 for manganese, 5 for nickel, 15 for iron, and 2 for osmium. Typically, the linearity of response spans four orders of magnitude, with atomic selectivity of metal versus carbon ranging from 2 to 3 orders. Response quenching by co-eluting hydrocarbons is not observed. As a demonstration experiment, the common analysis of methylcyclopentadienyl manganese tricarbonyl (MMT) in gasoline is carried out on an RFD system modified for dual-channel operation. The results show that dual-channel operation of the RFD can increase the native elemental selectivity of manganese over carbon by a factor of 100, in accordance with earlier ...

2002-02-03

202

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

203

Use of signal delay of one of detectors in two-channel radiometric flaw detector  

International Nuclear Information System (INIS)

A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.

204

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

209

Developments and tests of double-sided silicon strip detectors and read-out electronics for the Internal Tracking System of ALICE at LHC  

CERN Document Server

The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.

1999-01-01

210

Application of Pd silicide in the process of silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.

1990-04-01

211

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

212

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

213

Influence of Dopants on Characteristics of X-Ray Detectors Fabricated from Indium-, Gallium-, and Chlorine-Doped Cadmium Telluride Single Crystals  

Science.gov (United States)

Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.

1995-08-01

214

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this ...

2011-02-01

215

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

216

Radon Mapping of the Osijek Town  

International Nuclear Information System (INIS)

After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m"-"3, standard deviation of 44.0 Bq m"-"3 and geometric mean of 60.1 Bq m"-"3, for the radon concentration range from 23 to 186 Bq m"-"3. The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m"-"3, was in accordance with the theoretical log-normal distribution which was shown with #chi#"2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon measurement in the soil gas using radon emanators with ...

1998-11-11

217

On important matters (fire protection) related to No. 3 plant in the Hamaoka Nuclear Power Station, Chubu Electric Power Co., Inc., No. 2 plant in the Tsuruga Power Station, Japan Atomic Power Co., and No. 2 plant in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc  

International Nuclear Information System (INIS)

The Nuclear Safety Commission acknowledged the policy of the Agency of Natural Resources and Energy to cope with these important matters on August 8, 1984. The main contents of the investigation and deliberation were as follows, As to the prevention of the occurrence of fires, the prevention of the leak and spread of inflammable liquid and gas, the installation of protective relays and so on, the use of incombustible materials and aseismatic design and the installation of lightning arresters. As to the detection of fires and fire fighting, the proper selection and arrangement of fire detectors and extinguishers, the extinguishers which do not harm the safety function of structures and equipment, and the extinguishers which are not affected by natural phenomena. As to the reduction of the effect of fires, the proper installation of fire walls and extinguishers, and the high temperature shut off of nuclear reactors which is never hampered by any ...

1985-01-01

218

Nitrous oxide in coastal waters  

Energy Technology Data Exchange (ETDEWEB)

Measurements of dissolved and atmospheric nitrous oxide (N{sub 2}O) are presented for three coastal environments: (1) the central North Sea, (2) the German Bight, and (3) the Gironde estuary. The contribution of coastal regions to the oceanic emissions of atmospheric N{sub 2}O were also determined. N{sub 2}O was measured with a gas chromatograph equipped with an electron capture detector and analyzed. The surface waters of the central North Sea and the German bight were found to be near equilibrium with the overlying atmosphere, while the mean saturation in the Gironde estuary was 132%. Mean saturations in coastal regions without estuaries or upwelling phenomena were only slightly higher than in the open ocean. When estuaries and regions with upwelling are included, however, approximately 60% of the oceanic N{sub 2}O flux is attributable to coastal regions. A review of published data indicated that previous studies have seriously underestimated ...

1996-03-01

219

Method for controlling the liquid level of a steam generator for a sodium-cooled fast breeder reactor  

International Nuclear Information System (INIS)

Object: To control the average liquid level of each steam generator at a constant level irrespective of the flow rate of sodium thereby to decrease change in the retained amount of sodium and at the same time to improve the load response characteristic. Construction: A method for decreasing to as large an extent as possible a change in the amount of sodium retained in a steam generator due to change in the flow rate, which comprises the steps of detecting the main recirculating flow rate of liquid sodium by the use of a sodium flow rate detector, amplifying the detected flow rate signal depending upon the ratio between the flow rates respectively in a super-heater and a re-heater (distribution ratio), delivering the amplified signal to a function generator which generates a liquid level setting signal for maintaining the respective average liquid levels of the super-heater and the re-heater at constant levels irrespective of the flow rates, and delivering the ...

220

Interactions of Jet Fuels with Nitrile O-Rings: Petroleum-Derived versus Synthetic Fuels  

Energy Technology Data Exchange (ETDEWEB)

A transition from petroleum~derived jet fuels to blends with Fischer-Tropsch (F~T) fuels, and ultimately fully synthetic hydro-isomerized F-T fuels has raised concern about the fate of plasticizers in nitrile-butadiene rubber a-rings that are contacted by the fuels as this transition occurs. The partitioning of plasticizers and fuel molecules between nitrile a-rings and petroleum-derived, synthetic, and additized-synthetic jet fuels has been measured. Thermal desorption of o-rings soaked in the various jet fuels followed by gas chromatographic analysis with a mass spectrometric detector showed many of the plasticizer and stabilizer compounds were removed from the o-rings regardless of the contact fuel. Fuel molecules were observed to migrate into the o-rings for the petroleum-derived fuel as did both the fuel and additive for a synthetic F-T jet fuel additized with benzyl alcohol, but less for the unadditized synthetic fuel. The specific ...

2009-01-01

221

Development and manufacture of tritium-in-air monitors for Indian PHWRs  

International Nuclear Information System (INIS)

Tritium, a beta emitting gas at room temperature causes a biological hazard in the locations where it is present beyond acceptable limits. The hazard can be due to inhalation, and absorption by skin. Hence is the necessity of Tritium monitoring instruments/systems for ensuring safety in the PHWRs and the nuclear research plants and laboratories. It is desirable that the instruments address satisfactorily to certain factors like the following: (i) Wide range of Tritium concentrations - 1 to 104 DAC ( Derived Air Concentration) (ii) On-line monitoring features (iii) Small response time (On-spot instantaneous measurements) (iv) Portability (v) Mitigation of memory effects. This paper presents an overview of the Online Tritium in Air Monitoring Systems manufactured by ECIL for Pressurised Heavy Water Reactors at Tarapur, Kaiga, and Rawatbhata. Significant aspects of design, function, testing, limitations of the detectors and electronics and the ...

2009-10-01

222

Detection system characteristics using sup 252 Cf ionization chambers  

Energy Technology Data Exchange (ETDEWEB)

Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This paper illustrates the use of this type of source to determine ...

1990-01-01

223

Conceptual fusion power monitor based on the "1"6O(n,p)"1"6N reaction  

International Nuclear Information System (INIS)

The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.

1981-07-01

224

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

225

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

226

Core simulations using actual detector readings for a Canada deuterium uranium reactor  

Science.gov (United States)

This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.

1991-02-01

227

Stable Isotope-Coded Quaternization for Comparative Quantification of Estrogen Metabolites by High-Performance Liquid Chromatography-Electrospray Ionization Mass Spectrometry  

UK PubMed Central (United Kingdom)

A fast and sensitive LC-ESI-MS method is described for the comparative quantification of 16 estrogen metabolites based on the derivatization of estrogens with a novel derivatizing reagent, N-methyl-nicotinic...Full Text Available

2008-07-15

228

Quantification and deconvolution of asymmetric LC-MS peaks using the bi-Gaussian mixture model and statistical model selection  

UK PubMed Central (United Kingdom)

BackgroundLiquid chromatography-mass spectrometry (LC-MS) is one of the major techniques for the quantification of metabolites in complex biological samples. Peak modeling is one...Full Text Available

229

Partial purification and some properties of a cholinesterase from bush bean (Phaseolus vulgaris L.) roots.  

UK PubMed Central (United Kingdom)

A cholinesterase was partially purified from bush bean (Phaseolus vulgaris L.) roots by using acridinium-based ligand affinity chromatography. The procedure gave a 78-fold increase in specific activity,...Full Text Available

1978-12-01

230

Online quasi-continuous measurement of organic acids in the atmosphere  

Energy Technology Data Exchange (ETDEWEB)

The concentration of some organic acids in the atmosphere was determined using a wet effluent diffusion denuder-aerosol collector coupled with Ion Chromatography. Three organic acids and four inorganic anions were identified and quantified in the air sample, taken from the backyard of PSI. (author)

2002-03-01

231

Mycolic Acid Analysis by High-Performance Liquid Chromatography for Identification of Mycobacterium Species  

UK PubMed Central (United Kingdom)

Mycobacterium tuberculosis is the etiologic agent of tuberculosis and can be accurately detected by laboratories using commercial genetic tests. Nontuberculosis mycobacteria (NTM) causing other mycobacterioses...Full Text Available

2001-10-01

232

Location of an epitopic site on epiglycanin by molecular immunoelectron microscopy.  

UK PubMed Central (United Kingdom)

Antibodies of the IgM type present in rabbit anti-epiglycanin antiserum were purified by (NH4)2SO4 precipitation and by ion-exchange, affinity and gel-filtration chromatography. After papain treatment...Full Text Available

1985-04-01

233

Isozymes of the Glycolytic Enzymes in Endosperm from Developing Castor Oil Seeds 1  

UK PubMed Central (United Kingdom)

Ion filtration chromatography on diethylaminoethyl-Sephadex A-25 has been used to separate two isozymes each of triose phosphate isomerase, glyceraldehyde 3-phosphate dehydrogenase, glycerate 3-phosphate...Full Text Available

1982-04-01

234

Isolation, Purification, and Characterization of an Endogenous Root-promoting Factor Obtained from Basal Sections of Pear Hardwood Cuttings  

UK PubMed Central (United Kingdom)

Basal segments taken from Old Home and Bartlett pear hardwood cuttings collected at intervals during the rooting period in September were extracted with ethanol and fractionated by paper chromatography...Full Text Available

1967-04-01

235

Immunoreactive properties of anti-thyroglobulin autoantibodies isolated by affinity chromatography from human thyroiditis serum.  

UK PubMed Central (United Kingdom)

A Sepharose-coupled 19S human thyroglobulin has been used as an immunoadsorbent to isolate anti-thyroglobulin autoantibodies and to evaluate the antigen-antibody interactions. With the system proposed...Full Text Available

1978-02-01

236

High affinity of lead for fetal haemoglobin.  

UK PubMed Central (United Kingdom)

In-vitro experiments using 203Pb were performed to identify lead-binding components in human haemoglobin. Sephadex A-50 ion-exchange chromatography of haemolysate showed that different types of haemoglobin...Full Text Available

1980-08-01

237

Genetics of the mammalian phenylalanine hydroxylase system. Studies of human liver phenylalanine hydroxylase subunit structure and of mutations in phenylketonuria.  

UK PubMed Central (United Kingdom)

Phenylalanine hydroxylase was purified from crude extracts of human livers which show enzyme activity by usine two different methods: (a) affinity chromatography and (b) immunoprecipitation with an...Full Text Available

1979-08-01

238

Disulfide Bonds and the Quaternary Structure of Factor VIII/von Willebrand Factor  

UK PubMed Central (United Kingdom)

Human Factor VIII/von Willebrand factor, purified by calcium citrate-cellulose chromatography and 4% agarose gel filtration was subjected to sodium dodecyl sulfate gel electrophoresis on gels containing...Full Text Available

1978-09-01

239

Development and validation of a high performance liquid chromatography method for the simultaneous determination of aspirin and folic acid from nano-particulate systems  

UK PubMed Central (United Kingdom)

Attention has shifted from the treatment of colorectal cancer (CRC) to chemoprevention using aspirin and folic acid as agents capable of preventing the onset of colon cancer. However, no sensitive...Full Text Available

2010-09-01

240

Detection of Norspermidine and Norspermine in Medicago sativa L. (Alfalfa) 1  

UK PubMed Central (United Kingdom)

Shoot meristem tissues of alfalfa, Medicago sativa L., were found by high performance liquid chromatography analyses to contain the uncommon polyamines, norspermidine and norspermine....Full Text Available

1989-02-01

241

Characterization of group A streptococcal T-12 protein purified by ion-exchange column chromatography.  

UK PubMed Central (United Kingdom)

The aim of the present study was to describe the physicochemical characteristics of streptococcal T antigen. T protein isolated from Streptococcus pyogenes type 12 (R53/1077, Colindale) and purified...Full Text Available

1978-09-01

242

Cerebrospinal Fluid Steroidomics: Are Bioactive Bile Acids Present in Brain?*  

UK PubMed Central (United Kingdom)

In this study we have profiled the free sterol content of cerebrospinal fluid by a combination of charge tagging and liquid chromatography-tandem mass spectrometry. Surprisingly, the most abundant cholesterol...Full Text Available

2010-02-12

243

BIOASSAY AND CHEMICAL ANALYSIS FOR HAZARDOUS MATERIALS IN RESIDUAL OILS. VOLUME 2. APPENDICES  

Science.gov (United States)

The report gives results of an examination, including mutagenic screening, of the chemical composition of residual fuel oils and their column chromatography pre-fractions. A degree of correlation between composition and mutagenicity has been achieved. Radionuclide data has been o...

244

Anti-beta-endorphin immunoglobulin G in humans.  

UK PubMed Central (United Kingdom)

Human IgG specific for beta-endorphin was identified by enzyme-linked immunoabsorbent assay and isolated by affinity chromatography. From a sample of 27 subjects, three individuals with major depression...Full Text Available

1986-11-01

245

Amino acid analysis at the picomole level. Application to the C-terminal sequence analysis of polypeptides.  

UK PubMed Central (United Kingdom)

Amino acids labelled with dimethylaminoazobenzenesulphonyl chloride can be separated by reversed-phase high-pressure liquid chromatography and detected in the visible region (436 nm). All 19 naturally...Full Text Available

1981-12-01

246

Adenosine 5?-triphosphate sulphurylase from Saccharomyces cerevisiae  

UK PubMed Central (United Kingdom)

1. ATP sulphurylase from Saccharomyces cerevisiae was purified 140-fold by using heat treatment, DEAE-cellulose chromatography and Sepharose 6B gel filtration. 2. The enzyme was stable...Full Text Available

1973-07-01

247

Environmental trace gas analysis by proton-transfer-reaction mass spectrometry (PTR-MS)  

International Nuclear Information System (INIS)

The work presented here demonstrates the ability of proton-transfer-reaction mass spectrometry (PTR-MS) to perform fast-response measurements of volatile organic compounds (VOCs) (including methanol, acetonitrile, acetaldehyde, acetone, PAN-type compounds, alpha- and beta-pinene, nopinone and pinonaldehyde) at the pptv level and its versatile applicability in the field of environmental trace gas analysis. Laboratory and field experiments including various calibration techniques and intercomparisons with other measurement techniques such as gas chromatography, atmospheric pressure chemical ionization and Fourier transformation infrared spectroscopy were performed providing a first characterization of the PTR-MS instrument performance (sensitivity, detection limit, precision, accuracy). Typically a detection limit (S/N=2) of 50 pptv for a 10 s signal integration time, a precision of 5 % and an accuracy in the range between 10 ...

248

Effects of temperature and the use of macroreticular resins in lithium isotope separation by displacement chromatography  

Energy Technology Data Exchange (ETDEWEB)

The effects of temperature and the use of macroreticular resins were studied in lithium isotope separation by an ion-exchange method. The isotope separation factors obtained decreased by increasing the temperature, and the factors for macroreticular resins were identical with those for the usual gel-type resins. However, the performance of isotope separation per unit band length in displacement chromatography was found to be improved by increasing the temperature and using macroreticular resins, because accelerating the interphase mass transfer caused the reduction of HETP (Height Equivalent to a Theoretical Plate).

1983-01-01

249

Quantum entanglement, recoherence and information flow in an accelerated detector - quantum field system: Implications for black hole information issue  

CERN Document Server

We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the detector never ...

2007-01-01

250

Geochemical and petrographic properties of some Spitsbergen coals and dispersed organic matter  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the characteristics of selected parameters of organic matter of the Tertiary coal samples and organic matter of Carboniferous rock samples from the Spitsbergen. The coal samples were taken from Central Coal Basin (the Longyearbyen region) and from the Forlandsundet Basin (Oscar II Land, the Kaffioyra region). Samples of dispersed organic matter were collected from Suffolk Pynten and Sergeijevfjellet area in Sorkapp Land. The optical properties of coal samples are different from properties of dispersed organic matter. Macerals of vitrinite group dominate in all of the samples. The average content of vitrinite group macerals is much lower in dipersed organic matter samples than it is in coals. The average content of liptinite group macerals is a little lower, and inertinite group macerals is much higher. The average content of mineral matter is higher in organic matter samples than in coal samples. The average value of vitrinite reflectance and standard deviation of ...

2004-02-20

251

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

252

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

253

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate ...

1988-12-01

254

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

255

Detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is ...

1991-03-13

256

Conventional detectors for a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).

1995-02-01

257

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

259

Method of purifying a gas mixture containing undesirable gas compounds  

Energy Technology Data Exchange (ETDEWEB)

The invention relates to a method for purifying a gas mixture containing at least one undesirable gas compound utilizing certain sulfonamide or sulfamide solvents.

1985-03-12

261

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

262

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

263

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

264

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

265

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

266

GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector  

Science.gov (United States)

We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon

2007-01-01

267

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

269

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

270

Advances in imaging THGEM-based detectors  

International Nuclear Information System (INIS)

We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.

2007-03-01

271

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

272

A review of 4 norm industries in Ireland  

Energy Technology Data Exchange (ETDEWEB)

Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the bauxite/alumina refining industry. For the ...

2006-07-01

273

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

274

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

275

Position detector design using an electrostatic application of ANSYS[sup TM  

Energy Technology Data Exchange (ETDEWEB)

The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.

1994-10-10

276

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

277

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

278

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

279

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

280

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

281

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum ...

2004-12-07

282

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the ...

2009-07-23

283

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

284

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

285

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

286

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

287

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

288

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

289

A Detector for 2-D Neutron Imaging for the Spallation Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)

2006-07-01

290

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

291

Ideal gas of tachyons  

Energy Technology Data Exchange (ETDEWEB)

In this paper we consider properties of the ideal gas of classical (nonquantum) tachyons.

1983-10-15

292

CONVERTING WASTE  

Wastenet

condenser, gas refiner, oil (gas) storage tank and dual fuel engine

294

Neutron detector counting capabilities for /sup 10/B-lined and /sup 235/U fission chambers in high gamma-ray fluxes  

Energy Technology Data Exchange (ETDEWEB)

This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...

1985-03-01

295

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...

1992-10-01

296

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background reduction through ...

2004-01-01

297

Gasmap 2006. Bringing Norwegian gas to Europe; En publikasjon om norsk gass og gasseksport  

Energy Technology Data Exchange (ETDEWEB)

A publication on Norwegian gas and gas export. The content is wide spread from use of gas in daily life via sub sea pipeline repair systems to an overview over tomorrows gas fields. (AG)

2006-06-15

298

The isolation of "1"3"9Ce after production by a proton-induced nuclear reaction on praseodymium  

International Nuclear Information System (INIS)

A method, based on anion exchange chromatography, is presented for the isolation of "1"3"9Ce after production by a proton-induced nuclear reaction on a thick praseodymium target. After bombardment the target is dissolved in nitric acid and "1"3"9Ce oxidised to the Ce(IV) oxidation state with bromic acid. "1"3"9Ce is then separated form the praseodymium by anion exchange chromatography on a Ag MP-1 resin column in a nitric acid - bromic acid mixture. "1"3"9Ce is sorbed onto the resin column and praseodymium eluted with the acid mixture. The bromic acid is washed out of the column with nitric acid and "1"3"9Ce finally eluted with dilute nitric acid containing sulphur dioxide.

2001-02-17

299

Separation of /sup 203/Pb by ion-exchange chromatography on Chelex 100 after production of /sup 203/Pb by the Pb(p,xn)/sup 203/Bi/sup EC. beta. +/ -> /sup 203/Pb nuclear reaction  

Energy Technology Data Exchange (ETDEWEB)

Bismuth radioisotopes, produced by 50-MeV proton bombardment of a lead target in a cyclotron, are separated from the lead target material by ion-exchange chromatography on a column containing 5.0 ml of Chelex 100. After a decay period of 24 hr, the /sup 203/Pb formed in situ is eluted from the column and then separated from /sup 200/Tl and /sup 201/Tl on a second ion-exchange column containing 0.5 ml of Chelex 100. Separations are sharp and carrier-free /sup 203/Pb is obtained.

1989-04-01

300

Rapid determination of granisetron in human plasma by liquid chromatography coupled to tandem mass spectrometry and its application to bioequivalence study  

British Library Electronic Table of Contents (United Kingdom)

A simple, sensitive and rapid method for analysis of granisetron in human plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and validated to satisfy FDA guidelines for bioanalytical methods. The analyte and internal standard (IS) were isolated from 100ml plasma samples by liquid-liquid extraction (LLE). A Varian 1200l tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 313.4/138 for granisetron and m/z 270/201 for the IS used for quantitation. The assay exhibited a linear dynamic range of 0.02-20ng/ml for granisetron in human plasma. The lower limit of quantification (LLOQ) was 0.02ng/ml with a relative standard deviati...

2006-01-01

301

Industrial application of green chromatography-I. Separation and analysis of niacinamide in skincare creams using pure water as the mobile phase  

British Library Electronic Table of Contents (United Kingdom)

In this work, chromatographic separation of niacin and niacinamide using pure water as the sole component in the mobile phase has been investigated. The separation and analysis of niacinamide have been optimized using three columns at different temperatures and various flow rates. Our results clearly demonstrate that separation and analysis of niacinamide from skincare products can be achieved using pure water as the eluent at 60^oC on a Waters XTerra MS C18 column, a Waters XBridge C18 column, or at 80^oC on a Hamilton PRP-1 column. The separation efficiency, quantification quality, and analysis time of this new method are at least comparable with those of the traditional HPLC methods. Compared with traditional HPLC, the major advantage of this newly developed green chromatography techniq...

2011-01-01

302

Fractionation of isotopes of alkali metals and alkaline earth metals in ion exchange chromatography  

International Nuclear Information System (INIS)

Fractionation of isotopes of the alkali metals and the alkaline earth metals in ion exchange chromatography of their chlorides was studied. The heavier isotopes of potassium and rubidium were found to be preferentially fractionated into the ion exchanger phase while the lighter isotopes of lithium, magnesium, calcium and strontium were enriched in the exchanger phase. This can be interpreted as a resultant of the relative significance of isotope effect upon dehydration and isotope effect accompanying the phase change of the hydrated metal ion. Found was no evidence of anomalous isotope effect attributable to the odd-even difference in mass number of isotopes. Based on the spectroscopic and solution chemical data (experimental and theoretical), the isotopic reduced partition function ratios of the hydrated alkaline metal ions and stretching force constants of metal ion-hydrating water bonds were estimated. (author).

303

Development and validation of a reference measurement procedure for certification of phenytoin, phenobarbital, lamotrigine, and topiramate in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Phenytoin (PHT), phenobarbital (PHB), lamotrigine (LTG), and topiramate (TPM) are some of the most widely used antiepileptic drugs (AEDs). Monitoring of their concentrations in serum is important for the treatment of epilepsy. A reference measurement procedure (RMP) for certification of PHT, PHB, LTG, and TPM in serum has been developed and critically evaluated. Isotopically labeled compounds of PHT, PHB, LTG, and TPM are used as internal standards for the four AEDs. The four drugs and their respective labeled internal standards are simultaneously extracted from serum using solid-phase extraction prior to reversed-phase liquid chromatography?tandem mass spectrometry (LC-MS/MS). Chromatographic separation was performed using a C18 column. Electrospray ionization (ESI) in the positive ion mo...

2011-01-01

304

Determination of low-molecular-weight organic acids and inorganic anions by gradient elution chromatography  

Energy Technology Data Exchange (ETDEWEB)

Conditions of the separation and detection of organic and inorganic anions by gradient ion chromatography and suppressed conductivity detection were studied, and the procedure of gradient elution was optimized. A detection limit of 1 x 10{sup -3} {mu}g x L{sup -1} was obtained using the pre-concentrated column and most relative standard deviations obtained in the determination of seven organic and inorganic anions were below 5%. This method was proved to be simple, rapid and accurate for the separation and determination of low-molecular-weight organic acids and inorganic anions and could be applied in the analysis of the samples from water and steam systems of thermal power plants with satisfactory results. (orig.)

2007-03-15

305

Detection of glycoproteins in the Acanthamoeba plasma membrane  

International Nuclear Information System (INIS)

In the present study the authors have shown that glycoproteins are present in the plasma membrane of Acanthamoeba castellanii by utilizing different radioactive labeling techniques. Plasma membrane proteins in the amoeba were iodinated by "1"2"5I-lactoperoxidase labeling and the solubilized radiolabeled glycoproteins were separated by lectin-Sepharose affinity chromatography followed by polyacrylamide gel electrophoresis. The periodate/NaB"3H_4 and galactose oxidase/NaB"3H_4 labeling techniques were used for labeling of surface carbohydrates in the amoeba. Several surface-labeled glycoproteins were observed in addition to a diffusely labeled region with M_r of 55,000-75,000 seen on electrophoresis, which could represent glycolipids. The presence of glycoproteins in the plasma membrane of Acanthamoeba castellanii was confirmed by metabolic labeling with ["3"5S]methionine followed by lectin-Sepharose affinity chromatography and polyacrylamide gel ...

306

Detection of 36 antibiotics in coastal waters using high performance liquid chromatography-tandem mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Among pharmaceuticals and personal care products released into the aquatic environment, antibiotics are of particular concern, because of their ubiquity and health effects. Although scientists have recently paid more attention to the threat of antibiotics to coastal ecosystems, researchers have often focused on relatively few antibiotics, because of the absence of suitable analytical methods. We have therefore developed a method for the rapid detection of 36 antibiotic residues in coastal waters, including tetracyclines (TCs), sulfanilamides (SAs), and quinolones (QLs). The method consists of solid-phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis, using electrospray ionization (ESI) in positive mode. The SPE was performed with Oasis HLB and Oasi...

2011-01-01

307

Analysis of organic acids in the pyrohydrolysis distillate of (U,Pu) mixed carbide fuel by ion chromatography  

International Nuclear Information System (INIS)

The study reports the identification of different organic acids that are formed during the pyrohydrolysis of mixed carbide of uranium and plutonium using ion chromatography (IC). The identification of organic acids present in the pyrohydrolysis distillate is required to carry out interference free analysis of Cl and F. The study describes three stage isocratic separations with NaOH eluents having concentrations 2 mM, 10 mM and 50 mM respectively in order to separate and identify both aliphatic and aromatic acids. The present investigation identified formic, acetic, propionic, butyric, tartaric and oxalic acids in the distillate, however, aromatic acids could not be identified. (author)

2011-02-22

308

A liquid chromatography?fluorimetric method for the in vitro estimation of the skin penetration of disodium phenyldibenzimidazole tetrasulfonate from sunscreen formulations through human skin  

British Library Electronic Table of Contents (United Kingdom)

Disodium phenyldibenzimidazole tetrasulfonate (PDT) is a new organic UV filter with hydrophilic properties used in modern sunscreen spray formulations. The aim of this work was to develop and validate an analytical method that can be used to study skin absorption of PDT from sunscreens. Results obtained in vitro for human skin showed a low level of absorption. The proposed in vitro method employs a diffusion cell. Sunscreen lotion was applied onto pretreated human skin, which was then placed in the cell. PDT was collected in a receptor liquid, the surface of which was in contact with the skin. The solutions obtained were diluted appropriately and analyzed by liquid chromatography without any interference. The analytical features of chromatographic determination with fluorimetic detection w...

2006-01-01

309

A model for the devolatilization of a coal particle sufficiently large to be controlled by heat transfer  

Energy Technology Data Exchange (ETDEWEB)

This study follows previous experimental work showing that the shrinking-core model applies to the pyrolysis (i.e., heating in the absence of oxygen) of particles (diam.{approx}14 mm) of a bituminous coal or a lignite in a fluidized bed at 700-950 {sup o}C. These experimental facts are in accord with the production of volatile matter being endothermic and not thermoneutral, as often assumed. Also, the rate at which volatile matter is produced in the presence of oxygen (i.e., devolatilization) or in its absence (pyrolysis) is demonstrated here to be controlled not at all by mass transfer, but by heat conduction to a moving reaction front inside a coal particle, provided its diameter exceeds {approx}3 mm. The resulting steady-state model of devolatilization indicates that six dimensionless groups are required to describe the rate of(I)coal->char+volatile matter for a nonfragmenting and nonswelling coal. This reaction occurs for a total time of c{sub 1}r{sub 0}+c{sub 2}r{sub 0}{sup ...

2006-08-15

310

Yield-increasing additives in kraft pulping: Effect on carbohydrate retention, composition and handsheet properties  

Energy Technology Data Exchange (ETDEWEB)

In this thesis, increased hemicellulose retention during kraft pulping has been studied. The work has been divided into three parts: i) Development of an accessible and reliable method for determination of carbohydrate composition of kraft pulps ii) Investigation of the composition and molecular mass distributions of the carbohydrates in kraft pulps with increased hemicellulose content iii) Investigation of the effect of increased hemicellulose content on the sheet properties of kraft pulps with increased hemicellulose content. A method for carbohydrate determination was developed. In this method, enzymes are used to hydrolyse the pulp into monosaccharides. A relatively mild acid hydrolysis is performed prior to detection on an HPLC with an RI-detector. The pulp is not derivatized and no pre-treatment (mechanical or chemical) is needed to determine the carbohydrate composition using the method developed here. Peak deconvolution software is used to improve the ...

2008-07-01

311

Precise measurements of alpha particle counting efficiencies and mean ranges  

International Nuclear Information System (INIS)

Precise measurements of alpha particle counting efficiencies have been made using isotropic, infinitely thin alpha emitting sources placed in direct contact with a thin, end-window, gas flow proportional detector. Except for alpha particle absorption in the window material, this geometry approaches 2#pi#, such that the only other variation in the response of the counter is from the random decay of the source. The data are fitted to the expected linear function of count rate versus window thickness and the resulting fitting parameters are used to calculate the counting efficiencies for a given thickness of window material. Counting efficiencies for 5.31, 6.06, and 8,78 MeV alpha particles have been determined from sources of "2"1"0Po and the progeny of "2"1"2Pb. For the particular counter used, the counting efficiencies in counts per alpha and their respective relative standard deviations were 0.401 #+-# 0.12%, 0.418 #+-# 0.41%, and 0.455 #+-# ...

1978-12-01

312

Long pulse chemical laser. Final technical report  

Energy Technology Data Exchange (ETDEWEB)

This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation Facility. A Boeing IRAD funded theoretical study ...

1989-02-01

313

Gas fixation solar cell using gas diffusion semiconductor electrode  

Energy Technology Data Exchange (ETDEWEB)

A gas diffusion semiconductor electrode and solar cell and a process for gaseous fixation, such as nitrogen photoreduction, CO/sub 2/ photoreduction and fuel gas photo-oxidation are described. The gas diffusion photosensitive electrode has a central electrolyte porous matrix with an activated semiconductor material on one side adapted to be in contact with an electrolyte and a hydrophobic gas diffusion region on the opposite side adapted to be in contact with a supply of molecular gas.

1980-12-23

314

Separation of Pu-238 and Pu-242 from irradiated Am-241  

International Nuclear Information System (INIS)

... americium 241 americium 242 daughter products ion exchange chromatography isotope ratio neutron beams plutonium 238 plutonium 242 ... Authors Watanabe, Kenju; Sagawa, Chiaki; Ueno, Kaoru (Japan Atomic Energy Research Inst., Tokai, Ibaraki. Tokai Research Establishment)

315

Rhizobium fredii and Rhizobium meliloti produce 3-deoxy-D-manno-2-octulosonic acid-containing polysaccharides that are structurally analogous to group II K antigens (capsular polysaccharides) found in Escherichia coli.  

UK PubMed Central (United Kingdom)

The polysaccharide components from cultured cells of Rhizobium fredii USDA205 and Rhizobium meliloti AK631 were extracted with hot phenol-water and separated by repetitive gel filtration chromatography....Full Text Available

1993-06-01

316

Method for detecting and diagnosing disease caused by pathological protein aggregation  

Energy Technology Data Exchange (ETDEWEB)

A method is provided for detecting pathological macromolecules in a patient. The method is comprised of the following: obtaining body fluid from the patient; pretreating the body fluid; subjecting the pretreated body fluid to size-exclusion chromatography to create an excluded fluid; and analyzing the excluded fluid to detect macromolecules having a predetermined molecular weight. The method also allows for comparing elution spectra with reference spectra of suspect pathologic proteins.

2000-05-16

317

Metabolism and Binding of 14C-Maleic Hydrazide 1  

UK PubMed Central (United Kingdom)

Maleic hydrazide (MH) is taken up by corn and pea seedling roots and bound to some material which is insoluble in 80% ethanol or 5% trichloroacetic acid. 14C-MH is stable metabolically; chromatography...Full Text Available

1970-01-01

318

Lipophilic technetium complexes. Technetium chelates of some O, N, S donor Schiff bases  

Energy Technology Data Exchange (ETDEWEB)

Dianionic tridentate, O, N, S, Schiff bases derived from salicylaldehyde and 2-mercapto-amines react with Tc(V) gluconate to form radiochemically pure neutral Tc chelates. The existence of lipophilic Tc complexes could be proved by high voltage electrophoresis, thin layer chromatography and octanol/water partition coefficients. 11 refs.

1984-04-02

319

Lipophilic technetium complexes. Technetium chelates of some O, N, S donor Schiff bases  

International Nuclear Information System (INIS)

Dianionic tridentate, O, N, S Schiff bases derived from salicylaldehyde and 2-mercapto-amines react with Tc(V) gluconate to form radiochemically pure neutral Tc chelates. The existence of lipophilic Tc complexes could be proved by high voltage electrophoresis, thin layer chromatography and octanol/water partition coefficients. (author).

1984-04-01

320

Investigation of Symphytum cordatum alkaloids by liquid-liquid partitioning, thin-layer chromatography and liquid chromatography-ion-trap mass spectrometry  

Energy Technology Data Exchange (ETDEWEB)

From the alkalised crude extract of Symphytum cordatum (L.) W.K. roots, pyrrolizidine alkaloids (PAs) were extracted as free tertiary bases and polar N-oxides in a merely one-step liquid-liquid partitioning (LLP) in separation funnel and subsequently pre-fractionated by preparative multiple-development (MD) thin-layer chromatography (TLC) on silica gel plates. In this way three alkaloid fractions of different polarities and retention on silica gel plates were obtained as: the most polar N-oxides of the highest retention, the tertiary bases of medium retention, and diesterified N-oxides of the lowest retention. The former fraction was reduced into free bases by sodium hydrosulfite and purified by LLP on Extrelut-NT3 cartridge. It was further analysed together with the two other fractions by high-performance liquid chromatography (HPLC)-ion-trap mass spectrometry with atmospheric pressure chemical ionization (APCI) interface on XTerra C{sub 18} ...

2006-05-04

321

Determination of Carbaryl residues in soybean and peanut plants  

International Nuclear Information System (INIS)

Carbaryl is one of the insecticides used in large quantities in Indonesia. It is effective against soybean and peanut plant insects. The residues in the plants are determined by Colorimetry at the residues level up to 5 ppm and by thin layer chromatography at level up to 0,1 ppm. Both methods use coupling reaction between hydrolysis product of Carbaryl and diazo reagent to produce colour. (author).

1976-01-01

322

Comparison of ion chromatography and titrimetry for determination of sulfur in fuel oils  

Energy Technology Data Exchange (ETDEWEB)

A comparison was made of Parr bomb ion chromatographic and titrimetric methods to determine sulfur in fuel oils. The two methods are comparable in precision and accuracy. When rapid sulfur determination in a number of samples is desired, the titrimetry method appears to be an appropriate choice between the two methods. l3 tables.

1982-12-01

323

Characterization of hyaluronate binding proteins isolated from 3T3 and murine sarcoma virus transformed 3T3 cells  

Energy Technology Data Exchange (ETDEWEB)

A hyaluronic acid binding fraction was purified from the supernatant media of both 3T3 and murine sarcoma virus (MSV) transformed 3T3 cultures by hyaluronate and immunoaffinity chromatography. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis resolved the hyaluronate affinity-purified fraction into three major protein bands of estimated molecular weight (M/sub r,e/) 70K, 66K, and 56K which contained hyaluronate binding activity and which were termed hyaluronate binding proteins (HABP). Hyaluronate affinity chromatography combined with immunoaffinity chromatography, using antibody directed against the larger HABP, allowed a 20-fold purification of HABP. Fractions isolated from 3T3 supernatant medium also contained additional binding molecules in the molecular weight range of 20K. This material was present in vanishingly small amounts and was not detected with a silver stain or with (/sup 35/S)methionine label. The ...

1987-06-02

324

Characterization of DTPA complexes and conjugated antibodies of astatine  

International Nuclear Information System (INIS)

The complex formation of astatine(I) cation with diethylene triamine pentaacetic acid (DTPA) and characterization of the complexes were investigated by electromigration in free electrolytes and by gel-chromatography on Sephadex G 25. The conjugation procedure for the production of At-DTPA conjugated polyclonal antibodies is described. (author) 15 refs.; 2 figs.

325

Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector  

Energy Technology Data Exchange (ETDEWEB)

The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with ...

2006-07-01

326

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics ...

2000-01-01

327

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...

1997-02-01

328

Electronics for the Si detectors in APEX  

Energy Technology Data Exchange (ETDEWEB)

APEX (ATLAS Positron EXperiment), a collaborative effort of ANL, FSU, MSU/NSCL, Princeton, Queen`s, Rochester, Washington and Yale, is an experiment to study positron and electron production in very heavy ion collisions. The electrons and positrons are detected with two detector arrays, each consisting of 216 1 mm thick Si PIN diodes, and their energy and time-of-flight are measured. The number of detectors and limited space made it necessary to develop a system that could efficiently process and transfer signals from the detectors to the charge sensing ADC`s and data readout electronics as well as monitor the condition of the detectors. The discussion will cover the electronics designed for the Si detectors, including the charge amplifier, ``Mother board`` for the charge amplifiers, 8 channel Shaper, 16 channel Constant Fraction Discriminator (CFD), 16 channel Peak-to-FERA (PTF) ...

1994-07-01

329

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. Studies of the ...

330

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties ...

2007-06-11

331

The chain of the natural gas in Colombia  

International Nuclear Information System (INIS)

The book tries about the International and national aspects, natural gas situation, production, consumption, prices, demand projection, energetic plans, norms and laws of the natural gas in Colombia

2007-01-01

332

Overview of estimations of natural gas in small fields  

International Nuclear Information System (INIS)

An overview is given the expected amount of natural gas that can be produced from small gas fields in the Netherlands in the next 20 years.

2005-01-01

333

Natural gas annual 1996  

Energy Technology Data Exchange (ETDEWEB)

This document provides information on the supply and disposition of natural gas to a wide audience. The 1996 data are presented in a sequence that follows natural gas from it`s production to it`s end use.

1997-09-01

334

The hunt for ?13 at the Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.

2010-03-30

335

The cross-coupled interferometer for gravitational wave detection  

International Nuclear Information System (INIS)

The cross-coupled interferometer is a new design for interferometric gravitational wave detectors. Similar to the baseline gravitational wave detectors proposed for Advanced LIGO, it uses long-arm cavities in which the signal is generated. The signal fields are then extracted from the arm cavities with an additional cavity behind the long-arm cavities. The tuning of this signal extraction cavity and the parallel tuning of the signal recycling mirror can be used to optimize the peak frequency and the bandwidth of the detector independently. If we replace the signal recycling mirror by a small cavity, it is possible to amplify signals in two different frequency bands.

2002-04-07

336

Tests with superconducting re-entrant cavities for transducer applications in gravitational wave detectors  

International Nuclear Information System (INIS)

We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.

2004-03-07

337

Sudbury neutrino detector  

International Nuclear Information System (INIS)

The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.

338

Studies of a Poenitz-type black neutron detector as a neutron flux monitor  

Energy Technology Data Exchange (ETDEWEB)

A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).

1997-04-01

339

Silicon Detector Letter of Intent  

Energy Technology Data Exchange (ETDEWEB)

This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.

2010-05-26

340

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

341

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

342

A PDA-Based ECG Beat Detector for Home Cardiac Care.  

Science.gov (United States)

Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192

2005-01-01

343

Geochemical study on origin of natural gases in Japanese oil and gas fields  

Energy Technology Data Exchange (ETDEWEB)

The origin of natural gas in the Japanese oil and gas fields are geochemically studied. Samples are taken from structural natural gas, surface gas seepage, water-dissolved natural gas and coal-field gas of the Japan Sea coast area. The origins of primary hydrocarbons are classified into bacteria gas and thermogenic gas, the latter being subclassified into gas in oil production zone with the per million deviation of the carbon isotope (/sup 13/C/sup 1/) of methane less than -35 and those gases with maturity higher than this. Surface gas seepage is subjected to migration and bacterial oxidation. Coal gas is similar to oil gas. The CO/sub 2/ concentration is 0 - 2% and /sup 13/CO/sub 2/ deviations from -30 - +30. The origin can be barely ...

1988-05-01

344

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

345

The CDF intermediate silicon layers detector  

Energy Technology Data Exchange (ETDEWEB)

The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.

1999-11-01

346

The Brazilian Bragg curve detector built for AMS studies  

Energy Technology Data Exchange (ETDEWEB)

A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.

2000-10-01

347

Studies of relativistic heavy ion collisions at the AGS (Experiment 814)  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)

1990-01-01

348

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. ...

2001-01-01

349

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

350

Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information  

International Nuclear Information System (INIS)

The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)

2010-11-01

351

Radon concentration measurements by means of nuclear tracks detector with image analysis  

International Nuclear Information System (INIS)

English 1998 p. 124 Poland Antanasijevic, R. Vukovic, J. Novakovic, V. Tasic,

1998-09-15

352

Photoconductive ultraviolet detectors based on ZnO films  

British Library Electronic Table of Contents (United Kingdom)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...

2006-01-01

353

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

354

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...

2006-10-29

355

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

356

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

357

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through ...

1992-01-01

358

Linewidth-broadened Fabry-Perot cavities within future gravitational wave detectors  

International Nuclear Information System (INIS)

The bandwidth of LIGO-like terrestrial interferometric gravitational wave detectors is set by the pole of the Fabry-Perot cavities within the arms of the Michelson interferometer. This constraint arises because the gain of gravitational wave-induced signal sidebands is limited to frequencies within the linewidth of the cavities. The nature of standard Fabry-Perot cavities is such that one cannot independently adjust for increased gain without suffering a loss of bandwidth. If these quantities could be decoupled, the resulting improvement in bandwidth may lead to viable high frequency detectors. A pair of anti-parallel diffraction gratings within a Fabry-Perot cavity can increase the bandwidth of a LIGO-scale detector by a factor of #approx#1000.

2004-03-07

359

LAMBDA - IRAS Faint Source Survey Plates - LAMBDA - NASA  

Science.gov (United States)

Apr 18, 2008 ... The FSS was produced by point-source filtering the individual detector data ... a 1-sigma noise map; and a coverage map giving the count of ...

360

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in ...

2006-11-13

361

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

362

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-15

363

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-01

364

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

365

DESIGN, IMPLEMENTATION AND TESTING OF ... - LAMBDA - NASA  

Science.gov (United States)

FIG. 4. Power Spectral Density of the MAP W11 radiometer. The red and black traces are the power spectral density measurements of the two detectors on the ...

366

Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid  

CERN Document Server

In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.

1993-01-01

367

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

Energy Technology Data Exchange (ETDEWEB)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

1993-12-31

368

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

International Nuclear Information System (INIS)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

371

Annihilation of antiprotons in light nuclei  

CERN Document Server

CR-39 detectors have been exposed to a 5.9-MeV antiproton beam using the low energy antiproton ring (LEAR) facility at CERN. At this energy, tracks of antiprotons appear in a CR-39 detector after 135 min of etching in 6 M NaOH at 70C. Fluence of the antiproton beam has been determined using track density. We have also found tracks in the etched CR-39 detector at different depths (250-500 mum). These tracks have resulted from the annihilation of antiprotons with the constituents (H, C and O) of the CR-39 detector. The goal of the experiment is to develop a simple and low-cost method to study properties of antiparticles and those formed after annihilation of these particles with the target matter.

2006-01-01

372

AeroSpace Information for a Changing World - NASA Technical ...  

Science.gov (United States)

Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...

373
374

A Quantum-Enhanced Prototype Gravitational-Wave Detector  

CERN Document Server

The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point fluctuations of the electromagnetic field, which constrain the precision with which optical signals can be measured. In the world of precision measurement, laser-interferometric gravitational wave (GW) detectors are the most sensitive position meters ever operated, capable of measuring distance changes on the order of 10^-18 m RMS over kilometer separations caused by GWs from astronomical sources. The sensitivity of currently operational and future GW detectors is limited by quantum optical noise. Here we demonstrate a 44% improvement in displacement sensitivity of a prototype GW detector with suspended quasi-free mirrors at frequencies where the sensitivity is shot-noise-limited, by ...

2008-01-01

375

8 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

feature similar to the face detection in Intel's OpenCV library, implement it in Matlab code, and test the performance of the new ROI detector against the ...

378

Residential Mercury Spills from Gas Regulators  

UK PubMed Central (United Kingdom)

Many older homes are equipped with mercury-containing gas regulators that reduce the pressure of natural gas in the mains to the low pressure used in home gas piping. Removal of these regulators can...Full Text Available

2006-06-01

382

ON-LINE MONITORING OF FLUE GAS DESULFURIZATION ...  

Science.gov (United States)

... Title : ON-LINE MONITORING OF FLUE GAS DESULFURIZATION SCRUBBER CORROSION WITH ELECTROCHEMICAL TECHNIQUES. ...

1986-11-01

383

Flue Gas Desulfurization and Low Btu Gasification - A ...  

Science.gov (United States)

... Accession Number : ADD419503. Title : Flue Gas Desulfurization and Low Btu Gasification - A Comparison Appendix G. ...

1975-05-01

384

Flue Gas Desulfurization and Its Alternatives: The State of the ...  

Science.gov (United States)

... Accession Number : ADD419981. Title : Flue Gas Desulfurization and Its Alternatives: The State of the Art,. Corporate Author ...

1974-11-01

386

Plant for processing sewage gas to natural-gas quality  

Energy Technology Data Exchange (ETDEWEB)

Sewage gas or biogas as a product of anaerobic digestion contains methane and carbon dioxide as its main components. Biogas is scrubbed off carbon dioxide in absorption columns and purified to natural-gas quality. The purified gas then is piped to the gas pressure control station and fed into the public network. Description of process and plant is given.

1983-09-01

387

Micro gas turbine operation with biomass producer gas  

Energy Technology Data Exchange (ETDEWEB)

We report the performance of a micro gas turbine on biomass producer gas and mixtures of biomass producer gas with natural gas. The micro gas turbine delivers full power on gas mixtures with a heating value of at least 15 MJ/Nm{sup 3}. For gas of lower heating value, the maximum fuel gas flow limits the attainable power. The lower limit for stable operation is about 8 MJ/Nm{sup 3}. The gross efficiency of the micro gas turbine depends on output power but not on the gas heating value, within our measurement accuracy. Above 70% of full power, emissions of CO and NO are 40 and 10 times lower than those of a gas engine of similar size. At part load below 70% of full power, the micro gas turbine burner switches to a different operating mode ...

2007-08-15

388

Study on reactivity measurement by the Feynman-#alpha# method  

International Nuclear Information System (INIS)

The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).

1996-09-01

389

Si(111)/Gd: A fast and high-resolution thermal neutron detector  

Energy Technology Data Exchange (ETDEWEB)

Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.

1998-07-01

390

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

391

Research in experimental elementary particle physics. A proposal to the U.S. Department of Energy  

Energy Technology Data Exchange (ETDEWEB)

We report on the activities of the High Energy Physics Group at the University of Texas at Arlington for the period 1994-95. We propose the continuation of the research program for 1996-98 with strong participation in the detector upgrade and physics analysis work for the D0 Experiment at Fermilab, prototyping and pre-production studies for the muon and calorimeter systems for the ATLAS Experiment at CERN, and detector development and simulation studies for the PP2PP Experiment at Brookhaven.

1995-04-13

392

Radon concentration measurements in the soil  

International Nuclear Information System (INIS)

Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)

393

Proposed high-resolution vertex detector using superconductive thin strips  

Energy Technology Data Exchange (ETDEWEB)

The possibility of fabricating a superconductive vertex detector is discussed on the basis of a preliminary experiment. The experiment has shown that an indium strip 15 mm long, 20 ..mu..m wide and 0.1 ..mu..m thick is changed from the superconductive state to the normal state when struck by a single 5.4 MeV alpha particle.

1984-06-01

394

Performance of the transition radiation detector in D{Phi}  

Energy Technology Data Exchange (ETDEWEB)

The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.

1994-12-31

395

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

396

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

397

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

398

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

399

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

400

Medical explorations by radioisotopes in Lebanon  

International Nuclear Information System (INIS)

This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.

401

Interaction region layout of the VLEPP based photon linear collider with ultimate luminosity  

Energy Technology Data Exchange (ETDEWEB)

In the present paper, a possible interaction region layout of the VLEPP based Photon Linear Collider (PLC) with ultimate luminosity is discussed. In order to remove spent electron beams, the crab-crossing scheme is used. The detector is protected from produced pairs and secondary particles by means of the detector magnetic field and a shielding mask. ((orig.)).

1995-02-01

402

Gamma ray detecting device using dislocation-free crystal  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.

1991-04-30

403

GaAs detector optimization for different medical imaging applications  

International Nuclear Information System (INIS)

We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)

1999-09-11

404

Explosives detection: the problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.

1984-01-01

405

Direct gamma-spectrometry of surface activity with IGC-30 HPGe detector  

International Nuclear Information System (INIS)

The IGC-30 HPGe detector with MCA 'CANBERRA-10 PLUS' allows to determine surface contamination of areas of any type with a minimum error in radius 8-10 m, at a 'uniform' contamination. A modification of the CANBERRA hardware and software is described allowing determination of both the activity of a possible 'radioactive spot' and the activity of the whole observed surface. (author).

1993-12-02

406

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

407

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

408

Determination of reactor kinetic parameters in a two-core reactor  

Energy Technology Data Exchange (ETDEWEB)

The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.

1982-01-01

409

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

410

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

411

Detection device for high explosives  

Energy Technology Data Exchange (ETDEWEB)

A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

1992-01-01

412

Ceramic inspection system  

Science.gov (United States)

A system for inspecting a ceramic component. The ceramic component is positioned on a first rotary table. The first rotary table rotates the ceramic component. Light is directed toward the first rotary table and the rotating ceramic component. A detector is located on a second rotary table. The second rotary table is operably connected to the first rotary table and the rotating ceramic component. The second rotary table is used to move the detector at an angle to the first rotary table and the rotating ceramic component.

2006-05-16

413

CPA simulator: A software tool to simulate nuclear front-end circuit response  

International Nuclear Information System (INIS)

A computer program 'CPA simulator' has been designed to simulate the response parameters of a typical charge preamplifier (CPA) used in nuclear front-end electronics. The response parameters are studied considering three common connection methods between the detector and the CPA. The simulator predicts and illustrates the role and influence of the different components of the CPA and detector circuits.

2010-12-21

414

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and ...

1984-06-05

415

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

416

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side ...

2005-11-23

417

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

418

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation ...

1995-11-01

419

A solution for solid state detector and preamplifier protection, during HV application and removal transition periods  

International Nuclear Information System (INIS)

Surface barrier detectors may be damaged, because of microplasma breakdown, in rapid application of bias voltage. The high performance FETs of very low noise preamplifiers may also be damaged by rapid changes of the bias voltage. The electronic device described permits the gradual application and removal of the bias voltage, without any influence on the power supply specification. (Auth.).

420

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

421

Use of the WNR spallation neutron source at LAMPF to determine the absolute efficiency of a neutron scintillation detector  

Energy Technology Data Exchange (ETDEWEB)

Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.

1994-06-01

422

Recent Progress in CdTe and CdZnTe Detectors  

CERN Document Server

Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these ...

2001-01-01

423

GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy  

Energy Technology Data Exchange (ETDEWEB)

High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing layer only. Extended ...

2004-12-21

424

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an ...

2002-01-01

425

Design and implementation of the BESIII detector-control system  

Energy Technology Data Exchange (ETDEWEB)

In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has ...

2008-07-21

426

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. ...

2005-10-23

427

Engine use of producer gas, experiences and requirements  

Energy Technology Data Exchange (ETDEWEB)

The most effective way to generate electricity out of biomass is the gasification and the use of the gas in a gas engine. The conversion of the organic carbon with the gasification of biomass is higher than 95 %. Depending on the gasification concept, the efficiency of gasifiers is found between 70 and 90 %. If the pyrolysis gas is used in a gas engine, an electric efficiency of about 26 % referring to the primary amount of energy can be obtained. With efficient gas cleaning (cleaning for tar and dust), pyrolysis gas is well qualified for engine combustion. Through modern state of engine controlling there are ways to have complete control of the fluctuations in the gas composition. Furthermore, the minor calorific value of offered wood gas poses no problem for turbo charged lean-burn gas engines. ...

1999-07-01

428

Electrodeless lamp energized by microwave energy  

Energy Technology Data Exchange (ETDEWEB)

This patent describes an electrodeless lamp. It comprises: a microwave cavity; a source of microwaves in communication with the cavity; a lamp envelope containing a plasma-forming medium mounted within the microwave cavity; a gas manifold for feeding gas to at least one gas passageway for directing a stream of gas to the outer surface of the envelope; a gas leak passageway leading from the gas manifold; a conductive mesh assembly for retaining microwaves within the cavity and permitting light to be emitted from the cavity. The assembly including gas flow blocking means for preventing the flow of gas through the gas leak passageway when the screen is in place in the lamp; and means for shutting off the source of microwaves when the gas pressure in the manifold drops below a ...

1990-01-16

429

Flue gas desulfurization pilot study. phase i. survey of major installations. report no. 95. summary of survey reports on flue gas desulfurization processes  

Science.gov (United States)

Appendices to this summary consist of twelve individual status reports that will be available through the National Technical Information Service (NTIS) in the United States and of course limited copies will be available through NATO. The twelve report titles which are appendices to the summary are: (A) Status Report on the Limestone/Sludge Flue Gas Desulfurization Process; (B) Status Report on the Lime/Sludge Flue Gas Desulfurization Process; (C) Status Report on the Double Alkali/Sludge Flue Gas Desulfurization Process; (D) Status Report on the Sea Water Scrubbing Flue Gas Desulfurization Process; (E) Status Report on the Limestone/Gypsum Flue Gas Desulfurization Process; (F) Status Report on the Lime/Gypsum Flue Gas Desulfurization Process; (G) Status Report on the Double Alkali/Gypsum Flue Gas Desulfurization Process; (H) Status Report on ...

1979-01-01

430

Use of countercurrent liquid chromatography for the preconcentration and separation of inorganic compounds: group extraction of Zr, Hf, Nb, and Ta for their subsequent determination by inductively coupled plasma atomic emission spectroscopy  

International Nuclear Information System (INIS)

The possibility of the group preconcentration of Zr(4), Hf(4), Nb(5), and Ta(5) countercurrent liquid chromatography using extraction systems based on di-2-ethylhexylphosphoric acid N-benzoyl-N-phenylhydroxylamine, and tetraoctylethylenediamine (TOEDA) is studied. A method have been proposed for the group extraction of Zr(4), Hf(4), Nb(5), and Ta(5) from solution of geological samples. At the stage of the preconcentration of Zr(40, Hf(4), Nb(5) and Ta(5) with a 0.1 M solution of TOEDA in chloroform from mixture of oxalic (0.01 M) and hydrochloric (0.1 M) acids, matrix components are eluted with a flow of the mobile phase, Then, upon changing the eluent (2.0 M HCl), the four elements mentioned above are extracted to a small (7-8 mL) eluate fraction. The results of determining Zr, Hf, Nb, and Ta by inductively coupled plasma atomic emission spectrometry in the international standard reference material Granite GM after their preconcentration in the system with TOEDA ...

1997-11-01

431

The growth factor from plerocercoids of Spirometra mansonoides is both a growth hormone agonist and a cysteine proteinase.  

Science.gov (United States)

Plerocercoids of the tapeworm Spirometra mansonoides produce a substance that stimulates growth of experimental hosts. We report purification of plerocercoid growth factor (PGF) to homogeneity by a process involving isolation and solubilization of plerocercoid membranes, isoelectric point selection by chromatofocusing chromatography or preparative isoelectric focusing, and anion-exchange chromatography. A radioreceptor assay (RRA) for human growth hormone (hGH) was used to detect PGF and purity of the 27.5-kDa protein was judged by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Proteolytic activity was detected in the 27.5-kDa protein by gelatin substrate PAGE. Characterization of PGF as a neutral cysteine proteinase was based on substrate and inhibitor specificities and dependence on pH and thiol-containing reagents. The association of hGH agonist and proteinase activities was shown by comparing RRA and hydrolytic ...

1996-04-01

432

Separation of Minor Actinides and Lanthanides with Carbon Nano-materials  

Energy Technology Data Exchange (ETDEWEB)

Recently we have found that carbon nano-materials have ability to recognize softer actinides(III). In this presentation, separation of americium(III) from lanthanides(III) by chromatography with carbon nano-materials, such as carbon nano-tubes and graphite, has been investigated by batch adsorption experiments and chromatography. The separation factor (SF) between americium(III) and lanthanide(III) was about 2 in the range of pH from 1 to 4 by using carbon nano-tube, graphite and activated charcoal. The separation factor depended on the diameter of carbon nano-tubes. Smaller one, 3-20 nm diameter, showed the best selectivity for americium(III), which separation factor was about 2.0, although larger one, 40-70 nm, showed almost no selectivity. The same behavior has been observed by using graphite powder and activated charcoal although acid- or alkali pretreated activated charcoal which generally has acidic functional group on the edge of carbon ...

2009-06-15

433

Labelling of bleomycin with cobalt-57, indium-111, technetium-99m, mercury-197, lead-203, and copper-67  

International Nuclear Information System (INIS)

The radiochemical purity of the cobalt-57 complex of bleomycin could be enhanced by adjusting the pH of the final product to a value between 5 and 6. This radiopharmaceutical appeared to have better tumor visualizing properties compared to the not neutralized preparation. The clinical use of the cobalt-57 bleomycin complex is however limited by the long physical half-life of the label, causing a risk of radioactive contamination. It appeared to be possible to label bleomycin with radioactive cations ("1"1"1In"3"+, sup(99m)Tc"4"+, "1"9"7Hg"2"+ and "6"7Cu"2"+) having suitable gamma ray energies and short half-lifes. These bleomycin complexes showed a high radiochemical purity judged by their behaviour on thin layer chromatography, paper chromatography, and electrophoresis, but their application as tumor visualizing radiopharmaceutical turned out to be disappointing compared with cobalt-57 bleomycin. (orig.).

434

Determination of 40 synthetic food colors in drinks and candies by high-performance liquid chromatography using a short column with photodiode array detection  

British Library Electronic Table of Contents (United Kingdom)

Forty synthetic food colors were determined in drinks and candies by reversed-phase high-performance liquid chromatography with photodiode array detection. The following food colors were analyzed within 19min using a short analytical column (50mmx4.6mm i.d., 1.8mm) at 50degreeC with gradient elution: Ponceau 6R, Tartrazine, Fast yellow AB, Amaranth, Indigotine, Naphthol yellow S, Chrysoine, Ponceau 4R, Sunset yellow FCF, Red 10B, Orange G, Acid violet 7, Brilliant black PN, Allura red AC, Yellow 2G, Red 2G, Uranine, Fast red E, Green S, Ponceau 2R, Azorubine, Orange I, Quinoline yellow, Martius yellow, Ponceau SX, Ponceau 3R, Fast green FCF, Eosine, Brilliant blue FCF, Orange II, Orange RN, Acid blue 1, Erythrosine, Amido black 10B, Acid red 52, Patent blue V, Acid green 9, Phloxine B, Ben...

2008-01-01

435

Analysis of pesticides in dried hops by liquid chromatography-tandem mass spectrometry.  

Science.gov (United States)

An analytical method was developed for the determination of eleven agrochemicals [abamectin (as B1a), bifenazate, bifenthrin, carfentrazone-ethyl, cymoxanil, hexythiazox, imidacloprid, mefenoxam, pymetrozine, quinoxyfen, and trifloxystrobin] in dried hops. The method utilized polymeric and NH2 solid phase extraction (SPE) column cleanups and liquid chromatography with mass spectrometry (LC-MS/MS). Method validation and concurrent recoveries from untreated dried hops ranged from 71 to 126% for all compounds over three levels of fortification (0.10, 1.0, and 10.0 ppm). Commercially grown hop samples collected from several field sites had detectable residues of bifenazate, bifenthrin, hexythiazox, and quinoxyfen. The control sample used was free of contamination below the 0.050 ppm level for all agrochemicals of interest. The limit of quantitation and limit of detection for all compounds were 0.10 and 0.050 ppm, respectively. PMID:18593182

2008-07-02

436

Analysis of S-adenosylmethionine and related sulfur metabolites in bacterial isolates of Pseudomonas aeruginosa (BAA-47) by liquid chromatography/electrospray ionization coupled to a hybrid linear quadrupole ion trap and Fourier transform ion cyclotron resonance mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

A comprehensive and highly selective method for detecting in bacterial supernatants a modified sulfur nucleoside, S-adenosyl-L-methionine (SAM), and its metabolites, i.e., S-adenosylhomocysteine (SAH), adenosine (Ado), 5prime-deoxy-5prime-methylthioadenosine (MTA), adenine (Ade), S-adenosyl-methioninamine (dcSAM), homocysteine (Hcy) and methionine (Met), was developed. The method is based on reversed-phase liquid chromatography with positive electrospray ionization (ESI+) coupled to a hybrid linear quadrupole ion trap (LTQ) and 7-T Fourier transform ion cyclotron resonance mass spectrometry (FTICRMS). A gradient elution was employed with a binary solvent of 0.05 M ammonium formate at pH 4 and acetonitrile. The assay involves a simultaneous cleanup of cell-free bacterial broths by solid-pha...

2009-01-01

437

The nature of gas hydrates  

Energy Technology Data Exchange (ETDEWEB)

Gas hydrates have impacted the oil and gas industry since 1934, when they were first found to plug pipelines. Today we know that in deep oceans and in permafrost, very substantial gas reserves are present in hydrated form. Concerns are being raised about in situ dissociation for both energy and greenhouse implications upon methane release. In Japan work is underway to consider the storage of carbon dioxide, concentrated in clathrates. This talk will deal with some basic questions. Why should we be interested in gas hydrates? What are gas hydrates? How do gas hydrates form? How might hydrates impact on the energy/environmental picture?

1995-12-31

438

Gaseous dielectrics V  

Energy Technology Data Exchange (ETDEWEB)

This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmission lines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.

1987-01-01

439

Validation of radioimmunoassays for eicosanoids  

International Nuclear Information System (INIS)

The authors discuss radioimmunoassays (RIAs) for eicosanoids widely used in the field of experimental, clinical and pharmacological research. The main drawback of RIAs is the possibility of low specificity. This was clearly demonstrated during the controversy on plasma levels of 6-keto-PGF_1 #alpha#, the stable hydrolysis product of PGI_2. When extensive purification including reverse phase high pressure liquid chromatography (rp-HPLC) was performed prior to the RIA for 6-keto-PGF_1 #alpha# the levels were at least one order of magnitude less than previously claimed, and did not support the so-called circulating hormone hypothesis.

440

Transient impurity transport by automated ion chromatography  

International Nuclear Information System (INIS)

An ion chromatograph has been modified to automatically sample ten liquid water streams from the secondary side of three pressurized water reactors, Calvert Cliffs, Unit One, Rancho Seco and McGuire, Unit 1. Sampling and measurement is semicontinuous with a cycle time of approximately five hours for 10 locations with sensitivities in the range of 0.1 to 0.5 ppb. The efficiency of the condensate polishing system and subsequent transport of sodium, chloride, and sulfate around the system can be readily followed. Sulfate has been shown to have unusual volatility into the steam phase from the steam generator as well as a tendency to pass through the condensate polisher.

1985-03-01

441

Separation of lithium isotope by NTOE compound  

International Nuclear Information System (INIS)

Separation of lithium isotope by NTOE compound was carried out with 0.01M HCl solution. The ion exchange capacity of NTOE was 0.8 meq/g. The separation factor, #alpha#=("7Li/"6Li)_s_o_l_i_d/("7Li/"6Li)_l_i_q_u_i_d was 1.0242 by the elution chromatography. The lighter isotope, "6Li was concentrated in the liquid phase, while the heavior isotope, "7Li was enriched in the solid phase. (author).

442

Recovery of radioactive thallium isotopes from lead and bismuth targets irradiated by 1-GeV protons  

Energy Technology Data Exchange (ETDEWEB)

A simple highly efficient procedure has been developed for recovery of thallium radioisotopes from lead and bismuth targets irradiated by 1-GeV protons. The procedure is based on the use of extraction chromatography. The cross-sections have been determined for formation of {sup 200}Pb, {sup 201}Pb, {sup 202m}Pb, and {sup 203}Pb radioisotopes in targets from lead with natural isotopic composition, irradiated by 1-GeV protons.

1995-03-01

443

Recovery of radioactive thallium isotopes from lead and bismuth targets irradiated by 1-GeV protons  

International Nuclear Information System (INIS)

A simple highly efficient procedure has been developed for recovery of thallium radioisotopes from lead and bismuth targets irradiated by 1-GeV protons. The procedure is based on the use of extraction chromatography. The cross-sections have been determined for formation of "2"0"0Pb, "2"0"1Pb, "2"0"2"mPb, and "2"0"3Pb radioisotopes in targets from lead with natural isotopic composition, irradiated by 1-GeV protons.

444

Quality engineering and control. Semiannual progress report, May-October 1979  

International Nuclear Information System (INIS)

The following are reported: colorimetric determination of Ti in Cr, decontamination of metals by anodic dissolution, computer code for x-ray peak identification, gel-permeation chromatography of CoRezyn 1664 polyester resin, infrared monitoring of gases and vapors, particle size analysis of dusts, nondestructive analysis of Oralloy for removable alpha contamination, dissolution (digestion) of high-fired oxides, assay of U in a Pu-U alloy, measurement of oxide thickness on Pu metal by x-ray diffraction, analysis of precipitated Pu peroxide, differentiation of Dowex SBR and 11 resins, and determination of Pu solubility in simulated lung fluid.

445

Measurements for microamounts of SO_4"2"-, Br"-, I"- ions in the carnallite  

International Nuclear Information System (INIS)

The variations of measurements were estimated for microamounts SO_4"2"-, Br"-, I"- ions in samples of carnallite by ionchromatography method. The composition of carbonate eluent was verified. The investigated minima were about 0,004 %, 0,001 %, 0,01 % for SO_4"2"-, Br"-, I"- completively correspondingly. It was shown that the limit of ion-chromatography measurement would be decreased when Br"- and I"- ions were concentrated by extraction before. Besides the determination of I"- ion in carnallite was preformed by potentiometry with I"--ionselective electrode. 6 refs.; 3 tabs.

1995-01-01

446

Mass fragmentographic determination of polymethylnaphthalene and polymethylphenanthrene in a crude oil and in marine organisms  

Energy Technology Data Exchange (ETDEWEB)

The investigation of the petroleum contamination in marine organisms requires the trace level quantitative determination of indicative substances to be identified by a fingerprint of petroleum. Polymethylnaphthalene (PMN) and polymethylphenanthrene (PMP) were chosen because of their simple separation from a crude oil by means of an activated charcoal chromatography, their relatively high existence in aromatic compounds, and their persistence relative to other petroleum components in the tissue of oil contaminated marine organisms. The purpose of this paper is to present an activated charcoal chromatographic separation procedure of PMN and PMP in a crude oil and a trace level quantitative analytical method of them in marine organisms by mass fragmentography (MF).

1980-09-01

447

LC-MS characterization of metoclopramide photolysis products  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to investigate the photodegradation of the antiemetic drug metoclopramide. Metoclopramide aqueous solutions were photoirradiated at 254nm under argon atmosphere. Irradiated metoclopramide solutions were analyzed by high performance liquid chromatography-ion trap mass spectrometry in order to characterize photolysis products. Rapid decrease in metoclopramide purity, following first-order kinetic, was observed following irradiation. The structures of 18 photolysis products were tentatively identified based on their mass spectra and fragmentation. The main degradation mechanism was scission of the chlorine which could be followed by polymerization of the resulting products since dimeric and trimeric products were observed.

2009-01-01

448

Isolation and amino acid sequence of a short-chain neurotoxin from an Australian elapid snake, Pseudechis australis.  

Science.gov (United States)

A short-chain neurotoxin Pseudechis australis a (toxin Pa a) was isolated from the venom of an Australian elapid snake Pseudechis australis (king brown snake) by sequential chromatography on CM-cellulose, Sephadex G-50 and CM-cellulose columns. Toxin Pa a has an LD50 (intravenous) value of 76 micrograms/kg body wt. in mice and consists of 62 amino acid residues. The amino acid sequence of Pa a shows considerable homology with those of short-chain neurotoxins of elapid snakes, especially of true sea snakes. PMID:4091794

1985-12-01

449

Cooperative research in coal liquefaction infratechnology and generic technology development: Quarterly report, May 1, 1988--July 31, 1988  

Science.gov (United States)

Results of research programs in coal liquefaction are presented. Areas of research include: desulfurization by bioprocessing; characterization of coal liquefaction processes by XAFS spectroscopy; coprocessing of coal with heavy oil and petroleum residuals; liquefaction research in pyrolysis, catalysis and coal dissolution; novel catalysts; data base development; resource evaluation; depolymerization; solvent extraction and chromatography; correlations of liquefaction yields and coal structure. Individual projects are processed separately for the data bases. (CBS)

1988-01-01

450

Chromatographic separation of lithium isotopes by hydrous manganese(IV) oxide  

Energy Technology Data Exchange (ETDEWEB)

Separation of lithium isotopes was investigated by chemical ion exchange with a hydrous manganese(IV) oxide ion exchanger using an elution chromatography. The capacity of manganese(IV) oxide ion exchanger was 0.5 meq/g. The heavier lithium isotope was enriched in the solution phase, while the lighter isotope was enriched in the ion exchanger phase. The separation factor was determined according to the method of Glueckauf from the elution curve and isotopic assays. The separation factor of {sup 6}Li{sup +} -{sup 7}Li{sup +} isotope pair fractionation was 1.018.

2001-06-01

451

An investigation of the retention of some radioelements on natural fibers  

International Nuclear Information System (INIS)

The retention of radio-Eu, Go, Cs and Sr, at the tracer level, on raw fibers produced from hemp, linen and Jute plants was investigated. The study was conducted from different media including: sea and tap waters, sodium chloride and nitric acid solutions of different Ph. The percentage retention and elution, on prolonged contact, varied from one element to another depending on conditions. Extraction chromatography columns, using these fibers as supporting material were also experimented. Results were discussed together with possible applications. 7 tabs.

452

A one-pot radiosynthesis of ["1"2"5I]iodoazido photoaffinity labels  

International Nuclear Information System (INIS)

A useful method for preparing radioiodinated photoaffinity labels from alkyl anilines which offer significant advantages over present methods is described. The one-pot synthesis gives good radiochemical yields (40-64%) of pure, high specific activity (350-1500 mCi/#mu#mol) "1"2"4I labelled iodaryl azides while minimising manipulation of radioactive materials. Purification of the ["1"2"5I]iodoazido photoaffinity labels is achieved by high performance liquid chromatography. (author).

453

A one-pot radiosynthesis of ( sup 125 I)iodoazido photoaffinity labels  

Energy Technology Data Exchange (ETDEWEB)

A useful method for preparing radioiodinated photoaffinity labels from alkyl anilines which offer significant advantages over present methods is described. The one-pot synthesis gives good radiochemical yields (40-64%) of pure, high specific activity (350-1500 mCi/{mu}mol) {sup 124}I labelled iodaryl azides while minimising manipulation of radioactive materials. Purification of the ({sup 125}I)iodoazido photoaffinity labels is achieved by high performance liquid chromatography. (author).

1989-11-01

454

Well log evaluation of natural gas hydrates  

Energy Technology Data Exchange (ETDEWEB)

Gas hydrates are crystalline substances composed of water and gas, in which a solid-water-lattice accommodates gas molecules in a cage-like structure. Gas hydrates are globally widespread in permafrost regions and beneath the sea in sediment of outer continental margins. While methane, propane, and other gases can be included in the clathrate structure, methane hydrates appear to be the most common in nature. The amount of methane sequestered in gas hydrates is probably enormous, but estimates are speculative and range over three orders of magnitude from about 100,000 to 270,000,000 trillion cubic feet. The amount of gas in the hydrate reservoirs of the world greedy exceeds the volume of known conventional gas reserves. Gas hydrates also represent a significant drilling and production hazard. A fundamental question ...

1992-10-01

455

Well log evaluation of natural gas hydrates  

Energy Technology Data Exchange (ETDEWEB)

Gas hydrates are crystalline substances composed of water and gas, in which a solid-water-lattice accommodates gas molecules in a cage-like structure. Gas hydrates are globally widespread in permafrost regions and beneath the sea in sediment of outer continental margins. While methane, propane, and other gases can be included in the clathrate structure, methane hydrates appear to be the most common in nature. The amount of methane sequestered in gas hydrates is probably enormous, but estimates are speculative and range over three orders of magnitude from about 100,000 to 270,000,000 trillion cubic feet. The amount of gas in the hydrate reservoirs of the world greedy exceeds the volume of known conventional gas reserves. Gas hydrates also represent a significant drilling and production hazard. A fundamental question ...

1992-10-01

456

Micro Gas Turbine Operation with Biomass Producer Gas and Mixtures of Biomass Producer Gas and Natural Gas  

Energy Technology Data Exchange (ETDEWEB)

We report the performance of a commercial recuperated micro gas turbine on biomass producer gas and mixtures of biomass producer gas with natural gas. The biomass producer gas, obtained by gasification at 850{sup o}C with air at atmospheric pressure, contains about 7% H2, 17% CO, 15% CO2, 4% CH4, 2% other hydrocarbons, 2% H2O, and a balance of N2 and Ar from air. It has a net heating value of about 6 MJ/(Nm{sup 3}). The micro gas turbine delivers full power (30 kW{sub e}) on gas mixtures with a net heating value of at least 15 MJ/(Nm{sup 3}). For gas of lower heating value, the maximum fuel gas flow allowed by the fuel control unit limits the attainable power. At reduced power, the lower limit for stable operation is a net heating value of about 8 MJ/(Nm{sup 3}). The gross efficiency of the micro ...

2007-08-15

457

Use of receptor affinity chromatography in purification of the growth hormone-like factor produced by plerocercoids of the tapeworm Spirometra mansonoides.  

Science.gov (United States)

The plerocercoid stage of the tapeworm Spirometra mansonoides produces a functional analog of human growth hormone (hGH). Among the similarities between plerocercoid growth factor (PGF) and hGH is competition for the same receptors on rabbit liver membranes. To take advantage of this characteristic in a purification scheme for PGF, rabbit liver microsomes were solubilized in Triton X-100 and the hGH receptors were purified over an hGH affinity column. The purified receptors from six rabbit livers were coupled to Affi-Gel-10 to create a receptor affinity column which was used to purify PGF. Chromatography of crude PGF over the receptor column resulted in a 1044 fold increase in specific activity. SDS-PAGE in the presence of 2-mercaptoethanol showed that the affinity-purified PGF contained three protein bands with apparent Mrs of 27.5 K, 22 K, and 16.7 K. Injections of the partially-purified PGF into hypophysectomized rats produced a dose-dependent growth response ...

1988-01-01

458

One-step purification of Taq DNA polymerase using nucleotide-mimetic affinity chromatography.  

Science.gov (United States)

The thermostable Thermus aquaticus DNA polymerase (Taq Pol) has been the key factor in transforming the initial PCR method into one with huge impact in molecular biology and biotechnology. Therefore, the development of effective affinity adsorbents for the purification of Taq Pol, as well as other DNA polymerases, attracts the attention of the enzyme manufacturers and the research laboratories. In this report we describe a simple protocol for the purification of Taq Pol from E. coli lysates, leading to enzymes of high specific activity and purity. The protocol is based on a single affinity chromatography step, featuring an immobilized ligand selected from a structure-biased combinatorial library of dNTP-mimetic synthetic ligands. The ligand library was screened for its ability to bind and purify Taq Pol from E. coli lysates. One immobilized ligand (mABSGu) of the general formula X-Trz-Y, bearing 9-aminoethylguanine (AEGu) and aniline-2-sulfonic acid (mABS) linked ...

2007-01-01

459

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for ...

1997-05-01

460

A large surface neutron and photon detector for civil security applications  

Energy Technology Data Exchange (ETDEWEB)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...

2010-05-21

461

A large surface neutron and photon detector for civil security applications  

International Nuclear Information System (INIS)

The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...

2010-05-11

462

The natural gas industry - a survey; Erdgaswirtschaft - Eine Branche im Ueberblick  

Energy Technology Data Exchange (ETDEWEB)

The situation of natural gas in the Federal Republic of Germany is described, with particular emphasis on the advantages and consequences of natural gas supply. The brochure discusses the role of natural gas on the energy market, the reliability of natural gas supply, the environmental impacts, the energy-saving effect of natural gas, natural gas prices, the competitive strength of the German gas industry, and the long-term reliability of natural gas supply. (orig.) [German] Die Situation des Erdgases in der Bundesrepublik Deutschland wird beschrieben, wobei die wichtigsten Vorteile und Auswirkungen der Erdgasversorgung besonders hervorgehoben werden. Es geht um die Stellung des Erdgases im Energiemarkt, die Sicherheit der Energieversorgung, Umweltschutz, Energieeinsparung durch Erdgaseinsatz, Erdgaspreise, ...

2000-09-01

463

Study on low calorific gas combustion. Part 1  

Energy Technology Data Exchange (ETDEWEB)

Effects of combustion conditions on the critical calorific value of flame blowout were reported for low calorific gas on the assumption of using coal derived gaseous fuel. Further, calculations of adiabatic flame temperature by using chemical equilibrium calculation were conducted in order to get a possibility of increasing exit gas temperature of gas turbine combustor to 1,300 C for low calorific value gas fuel. As a result, effects of (1) fuel composition, (2) preheating fuel temperature, (3) calorific value, and (4) combustion air velocity and fuel nozzle diameter, on the critical calorific values of flame blowout were clarified. In increasing exit gas temperature of gas turbine combustor to 1,300 C when using low calorific value gas fuel, it is essential to get an advanced cooling technology for the gas turbine ...

1986-01-01

464

The origin of natural gas and the hydrocarbon charging history of the Yulin gas field in the Ordos Basin, China  

Energy Technology Data Exchange (ETDEWEB)

The genetic type, source and charging history of natural gas in the Yulin gas field in the Ordos Basin have been studied by combining the carbon isotopic composition of natural gas and geochemical characteristics of light hydrocarbons with carbon isotope fractionation model results and fluid inclusion analysis. The carbon isotopic composition of methane and ethane in the Yulin gas field is relatively enriched in {sup 13}C with {delta}{sup 13}C{sub 1} values ranging from - 35.3 permille to - 29.8 permille (average value = - 32.4 permille) and {delta}{sup 13}C{sub 2} ranging from - 26.3 permille to - 23.5 permille (average value = - 24.8 permille). The C{sub 7} light hydrocarbons are predominated by methylcyclohexane, accounting for 65.8% to 80.9% (average value = 71.6%), which is characteristic of coal-derived gas. Furthermore, the gas geochemistry indicates ...

2010-04-01

465

Study on the natural gas utilization in the ceramic industry; Estudo sobre a utilizacao do gas natural na industria ceramica  

Energy Technology Data Exchange (ETDEWEB)

The production, principal applications, characteristics and properties, advantages of the gas natural is showed. A sectorial overview of the ceramic industry and the utilization of the natural gas in the ceramic industry is presented. The expectations are systematized and the impact of the natural gas utilization in the ceramic industry is evaluated. Some conclusions are withdrawn and recommendations suggested.

1998-07-01

466

Combined gas/steam turbine process. Kombinierter Gas/Dampfturbinen-Prozess  

Energy Technology Data Exchange (ETDEWEB)

A combined gas/steam turbine process includes a high-pressure furnace and a high pressure gasification unit with a mounted upstream of a combustion chamber there is a gas turbine with a waste heat system. Combustion heat which is not needed to heat the flue gas to combustion temperature is released from the furnace and transferred to ths combustion air going into the combustion chamber.

1991-01-31

467

Charts estimate gas-turbine site performance  

Energy Technology Data Exchange (ETDEWEB)

Nomographs have been developed to simplify site performance estimates for various types of gas turbine engines used for industrial applications. The nomographs can provide valuable data for engineers to use for an initial appraisal of projects where gas turbines are to be considered. General guidelines for the selection of gas turbines are also discussed. In particular, site conditions that influence the performance of gas turbines are described.

1988-05-09

468

Bring money and natural gas; Part 5: The activities of Dutch companies in the East European natural gas market. Geld en gas meebrengen; Deel 5: Nederlandse bedrijven actief op de Oosteuropese gasmarkt  

Energy Technology Data Exchange (ETDEWEB)

The budding natural gas markets in East Europe attract a great deal of interest from natural gas industries in the Western countries. Dutch companies, institutions and the government, too, are active in this market. So far the results have not been spectacular. An analysis is made of the present situation and the Dutch approach

1993-09-01

469

Use of primary electron counting for detection of ultrasoft x-rays with a low-pressure multistep gaseous detector  

International Nuclear Information System (INIS)

The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.

470

Ultraviolet detectors based on ZnO films by thermal oxidation of Zn metallic films  

British Library Electronic Table of Contents (United Kingdom)

Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.

2008-01-01

471

Superconducting strip detectors as position sensitive particle detectors  

Energy Technology Data Exchange (ETDEWEB)

The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)

1994-02-01

472

Status of combined point source search with neutrino telescopes IceCube and AMANDA  

Energy Technology Data Exchange (ETDEWEB)

In this talk, we summarize recent results obtained from the combined neutrino telescopes IceCube and AMANDA. The combined approach, including data taken from both detectors simultaneously, is compared to other analyses that are using IceCube only data. The main benefit of the combined detector is its improved performance at low energies, meaning energies below 1 TeV (close to the energy threshold of the detector). The discussion is focused on the search for extra-terrestrial neutrinos from candidate sources in our Galaxy. Using appropriate cuts, the sensitivity can be optimized for soft spectra neutrino sources. With the resulting data sample, several studies are performed: an unbinned Galactic Plane Scan and a Cygnus region analysis: the Multi Point Source analysis. The current status of these analyses is presented.

2010-07-01

473

Spatial distribution of IGC-30 Ge-detector's efficiency  

International Nuclear Information System (INIS)

The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).

1993-12-02

474

Some considerations about future interferometric GW detectors  

International Nuclear Information System (INIS)

The two most important issues in designing future gravitational wave interferometric detectors are, in our opinion, thermal and optical noise. In this paper we discuss some approaches for reducing these noises. About thermal noise we show a possible cryogenic solution. About optical noise (namely, the combined effect of shot noise and radiation pressure noise) we show that it is possible to apply a recently proposed reduction strategy based on a 'quantum feedback' (Courty et al 2003 Phys. Rev. Lett. 90 083601; Courty et al 2003 Preprint gr-qc/0301068) to a full Fabry-Perot cavity. This can be seen as a further step towards the practical realization of a detector which is able to evade the standard quantum limit.

2004-03-07

475

Quartz fiber calorimetry and calorimeters  

CERN Document Server

Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward calorimeters.

2004-01-01

476

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

477

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

478

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.

479

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

480

Magnetic beam position monitor  

Energy Technology Data Exchange (ETDEWEB)

Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for ...

1995-12-31

481

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

482

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

483

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

484

High Energy Neutrino Telescopes  

CERN Document Server

This paper presents a review of the history, motivation and current status of high energy neutrino telescopes. Many years after these detectors were first conceived, the operation of kilometer-cubed scale detectors is finally on the horizon at both the South Pole and in the Mediterranean Sea. These new detectors will perhaps provide us the first view of high energy astrophysical objects with a new messenger particle and provide us with our first real glimpse of the distant universe at energies above those accessible by gamma-ray instruments. Some of the topics that can be addressed by these new instruments include the origin of cosmic rays, the nature of dark matter, and the mechanisms at work in high energy astrophysical objects such as gamma-ray bursts, active galactic nuclei, pulsar wind nebula and supernova remnants.

2008-01-01

485

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

486

Cooling device for impurity removal device in thermonuclear devices  

International Nuclear Information System (INIS)

Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).

1983-08-26

487

Aging measurements of a TMAE-based photon detector for the HERA-B RICH  

CERN Document Server

We report on aging measurements of a photon detector candidate for the HERA-B RICH. The prototype, a proportional wire chamber operated with TMAE, was mounted on an argon filled test-beam RICH and was aged by UV light at rates we expect in HERA-B. We monitored gain and current continuously, and checked the chamber with Cherenkov photons at regular intervals. The number of detected photons/track (projected to 2.75 m C sub 4 F sub 1 sub 0 in HERA-B) dropped from 26 to 11 after two days of aging - well below the 20 required for pi/K separation. Based on these results, HERA-B decided to use multi-anode PMTs as photon detectors in the RICH.

1999-01-01

488

Absolute subcriticality measurement without calibration and detection efficiency dependence by the /sup 252/Cf source-driven noise method  

Energy Technology Data Exchange (ETDEWEB)

The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.

1984-01-01

489

A planar circular detector based on multiple point chemi- or bio-luminescent source within a coaxial cylindrical reactor  

British Library Electronic Table of Contents (United Kingdom)

An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...

2009-01-01

490

Plan a perfect power plant  

Energy Technology Data Exchange (ETDEWEB)

This article puts the case for coal fired combined cycle gas turbine (CCGT) power plants. The need to gasify the coal for the CCGT, use of fluidised bed combustors or gasification systems, the difference in prices of coal and natural gas, and coal and natural gas reserves are discussed. (UK)

1995-04-01

491

Natural gas market review 2006 - towards a global gas market  

International Nuclear Information System (INIS)

Natural gas is essential to the world economy. Gas now accounts for almost a quarter of OECD primary energy requirements and is expected to become the second most important fuel in the world in the next decade. Industrial and residential consumers increasingly rely on natural gas to keep their houses warm, their lights on and their factories running. Meanwhile the gas industry itself has entered a new phase. Where gas used to be restricted to regional markets, it is now increasingly traded on a global scale. While gas production and transport requires long-term investment, now it is optimised on a short-term basis. Demand continues to grow, but local gas production has become much more expensive. How should we react? How will demand be satisfied? What changes are required to promote flexibility and trade? What are the implications for ...

492

Incorporate the latest FGD trends into mist-eliminator design. [Flue gas desulfurization  

Science.gov (United States)

Mist eliminators for flue gas desulphurisation units remove liquid droplets entrained in the flue gas leaving the SO/sub 2/-absorber vessels. The commercial designs currently available are described.

1984-03-01

493

Hybrid Gas/Electric Vehicle.  

Science.gov (United States)

The purpose of this project was to build a long-range, parallel hybrid gas/electric vehicle capable of driving beyond the communter capabilities of series hybrid vehicles. It was envisioned that since the gas engine would be able to independently propel t...

1985-01-01

494

Glass Furnace Combustion and Melting Research Facility.  

Energy Technology Data Exchange (ETDEWEB)

The need for a Combustion and Melting Research Facility focused on the solution of glass manufacturing problems common to all segments of the glass industry was given high priority in the earliest version of the Glass Industry Technology Roadmap (Eisenhauer et al., 1997). Visteon Glass Systems and, later, PPG Industries proposed to meet this requirement, in partnership with the DOE/OIT Glass Program and Sandia National Laboratories, by designing and building a research furnace equipped with state-of-the-art diagnostics in the DOE Combustion Research Facility located at the Sandia site in Livermore, CA. Input on the configuration and objectives of the facility was sought from the entire industry by a variety of routes: (1) through a survey distributed to industry leaders by GMIC, (2) by conducting an open workshop following the OIT Glass Industry Project Review in September 1999, (3) from discussions with numerous glass engineers, scientists, and executives, and (4) during visits to ...

2004-08-01

495

Radon in unconventional natural gas from Gulf Coast geopressured-geothermal reservoirs  

International Nuclear Information System (INIS)

Radon-222 has been measured in natural gas produced from experimental geopressured-geothermal test wells. Comparison with published data suggests that while radon activity of this unconventional natural gas resource is higher than conventional gas produced in the gulf coast, it is within the range found for conventional gas produced throughout the US. A method of predicting the likely radon activity of this unconventional gas is described on the basis of the data presented, methane solubility, and known or assumed reservoir conditions of temperature, fluid pressure, and formation water salinity.

496

Search for free quarks at PEP  

Energy Technology Data Exchange (ETDEWEB)

The results of a search for fractionally charged particles produced in e/sup +/e/sup -/ annihilation at 29 GeV/c/sup 2/ are discussed. Results from cosmic-ray searches for fractionally charged particles, tachyons, and massive particles using the same detector are also presented.

1982-01-01

497

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the ...

1999-07-01

498

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

Energy Technology Data Exchange (ETDEWEB)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

499

Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures  

International Nuclear Information System (INIS)

AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...

2002-04-01

500

Black holes as detectors of tachyons  

International Nuclear Information System (INIS)

Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).