This paper describes the design, operation, and performance of an HVAC system installed as part of a project to demonstrate energy efficiency and environmental responsibility in commercial buildings. The systems installed in the 2180 m{sup 2} office building provide superior air quality and thermal comfort while requiring only half the electrical energy of conventional systems primarily because of the hydronic heating and cooling system. Gas use for the building is higher than expected because of longer operating hours and poor performance of the boiler/absorption chiller.
In order to promote the use of natural gas air-conditioning systems in the tertiary sector, Gaz de France (the French gas utility) in association with Electricite de France (EdF) and the French chamber of council engineers (CICF) have created the Acerclim organization which aims at certifying the quality of the design, realization and exploitation of air processing and air-conditioning installations according to the ISO 9001 criteria. This article describes this quality procedure named 'CHSB Air'. (J.S.)
Petroleum is the unchallenged energy market leader in West Germany,having a share of 42%; natural gas accounts for 16-17%. West Germany imports 29% of its natural gas from the Soviet Union, 28% from the Netherlands, 14% from Norway, and 1% from Denmark. In West Germany many-branched natural gas distribution system is operated, equipped with a.o. 21 installations for underground storage which results in a great flexibility of the system. Because of the preferential treatment given to the use of coal as fuel for power plants the share of natural gas has decreased to the present 6% in the last ten years. In the indutrial sector the share is 18%. Strict air pollution abatement measures ('TA-Luft') favour the use of natural gas. However, duty has been levied on the use of natural gas per January 1st, 1989. For space heating of ...
Sep 21, 2006 ... NASA has selected Air Products and Chemicals, Inc., Allentown, Pa., to design, furnish and install a plant to produce liquid nitrogen for ...
At the 7th Healthy Buildings Conference, which was held in Singapore, 7-11 December 2003, more than 500 articles to improve public health and productivity of workers in buildings and the performance of installations. Special attention is paid to indoor air quality and thermal comfort in relation to energy efficiency. [Dutch] Op de laatste Healthy Buildings conferentie, december 2003 in Singapore, werden meer dan 500 artikelen gepresenteerd over het creeren van gezonde, productiviteit verhogende gebouwen en installaties. Deze keer lag de nadruk op binnenluchtkwaliteit en thermisch binnenklimaat, onder andere op het aspect energiezuinigheid. Opvallend was ook de aandacht die de problemen met binnenluchtkwaliteit in ontwikkelingslanden kreeg.
Concerning the above, it is discussed whether such a system is feasible in Japan. A zinc/air cell system requires some special plants for zinc regeneration, etc. It is necessary to build a zinc refining plant and to install dozens of electrode replacing facilities in an area dozens of kilometers in diameter with the plant at the center. For such a system to be functional, there have to be several tens of thousands of automobile users in a limited area. In Japan, so large a number will not be found anywhere even if the appeal is directed to those in the postal service and electric utilities. There will be no economic success in Japan, different from in Germany. As for the economic comparison between a zinc/air cell system and natural gas system, the two will be equivalent to each other as far as the use of the quick filling stations for the natural gas automobiles remains as it is. When the number in ...
In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.
In the construction work for the Unit No.5 Turbine Building at Hamaoka Nuclear Power Station, the collaboration work for the planning and the coordination of the building construction and the machinery installation was carried out utilizing three-dimensional computer aided design (3D CAD) information. It was the first time in Japan for a building constructor and a plant manufacturer to work together, exchanging 3D CAD data of the whole building and adjusting the construction schedule. It was made possible to confirm the correspondence concerning the planning of both companies from the primary stage of the project by the total process simulation and to adjust on-going work precisely by the partial process simulation.
Twenty years after its building, the tertiary sector of La Defense district near Paris has been rehabilitated. The main reason is not only the age and wear of materials but the heating costs, the fire protection regulations, the search for a better air quality and air renewing with less dusts, smells and noise and a controlled moisture. This paper describes first the original installation of the Monge CB 6 office building and then the renovated installation: the central hot and cold air-treatment plant, the variable flow ventilation system, the air extraction and supply system threw the roofs and the pressure and thermal regulation of the installation. (J.S.)
The largest solar heating and cooling system undertaken to date is now operating at the George A. Towns Elementary School in Atlanta, Georgia. It is expected to provide more than 60 percent of the building's heating and cooling requirements, using commercially available components and techniques. The Towns project is a United States Energy Research and Development Administration-sponsored experiment. The principal components of the solar heating and cooling system designed for the school--the solar collector array, the existing gas-fired boiler, the absorption chiller, and hot and cold water underground tanks to provide thermal storage--are described. To derive maximum benefit from the experiment, the system is fully instrumented for accurate measurement of performance. Environmental data, including insolation and ambient temperture, humidity, and wind conditions will be recorded. The inlet temperatures, outlet temperatures, and the ...
An uncomfortable thermal climate, draft complaints and a bad airquality are often related to the climate installation. To avoid badfunctioning of the system a number of preconditions has to be fulfilledwith regard to design, planning and execution, adjustments, completion,control, maintenance and management of the installations. First threetypes of health problems in buildings are shortly discussed: buildingrelated illness, sick building syndrome and building or installationrelated complaints. Then some functions of the climate installationsare described: air filtration, filter classes and filter quality, aswell as investment costs for better filters. Next the causes for thecomplaints are dealt with: air conditioning, ventilation, air quality,and temperatures. Subsequently health affecting aspects in relation tothe climate systems are discussed: outdoor air pollution,microorganisms, ...
The guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to quality assurance requirements for installation, inspection, and testing of mechanical equipment and systems for water-cooled and high-temperature gas-cooled nuclear power plants.
The purpose of this project was to build a long-range, parallel hybrid gas/electric vehicle capable of driving beyond the communter capabilities of series hybrid vehicles. It was envisioned that since the gas engine would be able to independently propel t...
Tohoku Electric Power Co., Ltd., is now building an LNG-fired No. 4 System (combined cycle of 1.61-million kW) for its Higashi Niigata Thermoelectric Power Station sited in the Niigata East Harbor industrial zone. This is a unit that aims at a thermal efficiency of 50% first in the world by using high-efficiency gas turbines, etc. After the completion of the No. 4 System, the station (No. 1 Machine, No. 2 Machine; No. 3 System, No. 4 System; Harbor No. 1 Machine, Harbor No. 2 Machine) will be generating a total power of 4.6kW, providing the company with its maximum power source which ranks among the largest-grade thermoelectric power stations in this country. Since the construction work was started in April, 1996, approximately 40% had been completed as of March-end, 1997, including foundations for the power station main building, stack, etc. The power station main building uses a raft foundation while ...
The fastest rate of growth in the space conditioning market has been attributed to the application of geothermal heat pumps to the industrial and commercial markets. The author reviews and provides examples of the three most popular components of a large geothermal heat pump system: geothermal earth coupling, heat pumps and heat exchangers, and building side terminals. These components are applied to three example geothermal installations: a library, an office building, and a school. Examples of energy use before and after the installation of a geothermal space conditioning system are summarized. General design and cost guidelines and comments on the use of geothermal heat pump in these and similar applications are discussed.
The risk perception of the public consists of two components: the objectively factual component and the subjectively irrational component. The two strategies adopted by the German gas supply industry are the internal and the external communication strategy. Concepts and measures of accident precaution, registration and analysis of accident data (installation and operating errors, defects on flue systems, pipelines and valves, subsequent installation of gas appliances) are discussed. (R.P.)
National Power is building its first gas turbine combined cycle power station at Killingholme, situated to the south of the River Humber in the East of England. NEI ABB Gas Turbines Limited was awarded the turnkey contract in July 1990 to build a nominal 650 MW combined cycle power station based around three Asea Brown Boveri GT13E gas turbines. The project is outlined in this article. The plant is due for completion in July 1993. (author)
More than sixty base-isolated buildings have been built in Japan. A number of base-isolation systems were considered in our research, which was intended to establish the effectiveness of base-isolation systems. We conducted research on silicone rubber bearings. Generally, silicone rubber is durable and its characteristics are not dependent on the temperature within the relevant design range. The first part of the report covers material and elements testing. After the bearings were installed in the building, we performed forced vibration tests in both the horizontal and vertical directions. These test results form the next section. After several experiments, we carried out earthquake observations. We report on the effectiveness of the system in reducing response acceleration during a small displacement. This system was installed in the building in March 1992
This report gives the results of a survey of operational flue gas desulfurization (FGD) systems on coal-fired utility boilers in the United States. The FGD systems installed on Units 1 and 2 at the Bruce Mansfield Station of the Pennsylvania Power Company...
The report, generated by a computerized data base system, presents a survey of operational and planned domestic utility flue gas desulfurization (FGD) systems, operational domestic particle scrubbers, and Japanese coal-fired utility FGD installations. It ...
The report discusses the capabilities of equipment vendors to supply and install the quantity of flue gas desulfurization systems required to meet alternative standards for coal-fired steam generators. It analyzes limiting factors affecting supply capabilities (such as the availa...
At the St. Joe Minerals Corp.'s zinc smelter powerplant, an SO2 emission control program evolved into a cooperative program with the Bureau of Mines for installation and initial operation of a citrate process flue gas desulfurization demonstration plant. ...
The ALICE experimental area management team faces various challenges when it comes to sharing scarce resources, indispensable to any efficient installation in a category one worksite. Space, cranes, jigs, and personnel with key competences have to be carefully allocated to activities so as to avoid slowing down work progress. To this intent, a resource loaded planning has been developed that allows highlighting coactivities and prioritizing critical tasks. It uses the built-in capabilities of Microsoft Project. The use of this scheduling tool leads to a more efficient use of time and a safer work environment. The installation sequence resulting from this schedule is presented in this paper. The first part of the sequence focuses on the revision of the coils in the SX2 building. The dipole has then to be installed in the RB26 side of the UX25 cavern. This complex and resource intensive activity has to be ...
This guidebook concerns the design of air-conditioning and air-treatment installations in recent and old buildings. The design of indoor atmosphere treatment systems is based on a rigorous and safe methodology. The following aspects are reviewed: situation of ambient air treatment, different aspects of a project, humid-air technique, principles of air treatment, basic conditions for a successful project, determination of enthalpy and hydric loads of rooms, design of ambient treatment systems, cold water production using a thermodynamical system, aeraulics, hydraulics, acoustics, logics of operation, forecasting of energy consumptions, global management of air-conditioning installations, ambient air-treatment systems. (J.S.)
On nuclear power stations with high temperature reactors and helium turbine cycles (HTR-single circuits) the residual heat from the energy conversion process in the primary and intermediate coolers is removed from cycled gas, helium. Water, which is circulated for safety reasons through a closed circuit, is used for cooling. The primary and intermediate coolers as well as other cooling equipment of the power plant are installed within the reactor building. The heat from the helium turbine cycle is removed to the environment most effectively by natural draught cooling towers. In this way a net plant efficiency of about 40% is attainable. The low quantities of residual heat thereby produced and the high (in comparison with power stations with steam turbine cycles) cooling agent pressure and cooling water reheat pressure in the circulating coolers enable an economically favourable design of the overall 'cold end' to be ...
Indoor air exposures to gaseous contaminants originating in soil can cause large human health risks. To predict and control these exposures, the mechanisms that affect vapor transport in near-surface soils need to be understood. In particular, radon exposure is a concern since average indoor radon concentrations lead to much higher risks than are generally accepted for exposure to other environmental contaminants. This dissertation examines an important component of the indoor radon problem: the impacts of wind on soil-gas and radon transport and entry into buildings. The research includes experimental and modeling studies of wind`s interactions with a building`s superstructure and the resulting soil-gas and radon flows in the surrounding soil. In addition to exploring the effects of steady winds, a novel modeling technique is developed to examine the impacts of fluctuating winds on ...
There is increasing pressure to operate laboratory facilities in environmentally and financially sustainable ways. A key factor in achieving this goal is careful consideration of how energy is used by the buildings' ventilation system, both for conditioning air supplied to the laboratories and the energy used moving air through the building. Traditionally, laboratory energy use is treated as an engineering concern within the scope of the building's overall design and operation. However, this approach limits the involvement of key stakeholders in many important decisions and can lead to unexpected safety concerns for the laboratory's users. We believe that a broad view of the parties affected by a laboratory building's operations is necessary to avoid having the various stakeholders working...
This article discusses the use of five-core cables to provide utility customers with the best possible prerequisites for trouble-free operation of electrical installations and equipment. The TN-S system in buildings and the new TN-S-five-core house-connection cable for connections between the mains distribution point and buildings is introduced. The long-term target of providing TN-S-systems in power distribution even as far as the local transformer is also discussed. The advantages of the system are discussed and various configurations for different types of supply are described.
The U.S. Trade and Development Program (TDP) had received a request from the Hungarian Electricity Board (MVMT) for assistance in support of a feasibility study program to: (1) install new generation capability based on gas/oil fired combined cycle power plants, and (2) retrofit/refurbish a number of aging coal and oil fired steam plants. A Definitional Mission (DM) recommends that TDP fund the requested feasibility studies for new gas/oil fired combined cycle capabilities discussed in the Terms of Reference (TOR). Hungary will need to install significant new power capacity between now and the end of the century. Gas/oil fired combined cycle plants present probably the only option to install capacity rapidly. There is an opportunity for U.S. firms to supply technology and services with respect to these advanced power generation technologies.
In the first part of the nineties many office buildings were equipped with indoor climate installations which do not meet present standards. Several options are available to improve such installations for ventilation capacity, cooling capacity, thermal comfort and air quality. One of the options concern the installation of an air conditioner in combination with heat recovery. In this article attention is paid to the renovation of the air conditioning system in the Printer house, an office building in Zwolle, Netherlands. [Dutch] Begin jaren negentig zijn veel kantoorpanden gebouwd waarvan de klimaatinstallatie tegenwoordig niet meer voldoet. De ventilatiecapaciteit is ontoereikend en koeling is mondjesmaat aanwezig, of slechts als topkoeling. Het comfort en de luchtkwaliteit zijn dan ook onder de maat. Er zijn verschillende mogelijkheden om dit te verbeteren. Plaatsing van een ...
Prepared to make housing project managers, maintenance engineering staff, and designers and architects of HUD - assisted and HUD - insured housing projects and mobile home parks aware of their responsibilities under the Natural Gas Pipeline Safety Act, this handbook provides technical guidance for the reduction of gas leaks and the handling of gas leak incidents in residential areas. The hazards of natural gas, concern over gas safety in residential areas, applicable codes and standards, and sources of information and help are reviewed, along with maintenance and engineering considerations relating to gas pipe failures, the detection of gas leaks, appliance servicing, and pipe installation, repair, and replacement. Housing management considerations are also examined, with attention to recordkeeping and reporting, ...
The Cooling and Ventilation Group has started the LHC construction work in September 1999 and will get into full activity when LEP will be stopped and dismantled: in total 12 major contracts for an amount of about 120 MCHF will be established to build the needed installations for the LHC. The author will report on the current works that are in progress on the different LEP Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work, completed in the new surface buildings in Points 18, is currently held in Points 4 and 5. Point 1 will follow in the near future. The work for the Cooling plants comprehend the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, the buried pipes in Points 1 and 4. For all of these activities, an updated report of the progress of the work, of the planning and of the expenses is given. ...
This paper describes a Honshu-Shikoku linking transmission cable building plan and its technical features. The Chugoku District and the Shikoku District are supplied with power currently by the Chugoku-Shikoku trunk line of 220,000 volts. To cope with the anticipated power shortage, a plan was established to install power cables for 500,000 volts on the Honshu-Shikoku connecting bridge. The plan calls far an installation length of 127.4 km and a transmission capacity of 1.2 million kW per line. The cable installation on the Seto Bridge was completed already, the construction is now in the peak period for building steel towers on the land sections, and laying overhead cables and underground cables. Commencement of the operation is scheduled 1994 on one liner, and 2000 on two lines. The technical features include the Japan's first large-capacity, long-distance underground ...
The purpose of this study is to identify the radiative heat transfer augmentation by a coaxial cylinder introduced in the infinite cylindrical pipe enclosing a participating gas. The gas is either a mixture of water vapor and carbon dioxide or gray. The gas is assumed to be homogeneous at a constant temperature, and has a refractive index of unity. All of the surfaces are opaque and gray, diffusely emitting and reflecting at a constant temperature. The effect of system diameter, diameter ratio, wall emittances, gas and surface temperatures, mixture component on heat transfer augmentation are studied by using the zone method with participating gas radiative properties evaluated from the weighted sum of gray gases model. From the radiative equilibrium condition, the installed wall temperature is formulated and calculated by the iteration method. If the medium is a ...
The study discussed relates to the design and development of a process consisting of combining a reversible geothermal heat pump with thermal solar collectors for building heating and cooling and the production of domestic hot water. The proposed process, called GEOSOL, has been installed in a 180 m{sup 2} private residence in 2004. This installation is the subject of long-term experimental follow-up to analyse the energy-related behavior of the installation at all times of the year. In addition, different configurations of this combined system (geothermal heat pump and thermal solar collectors) have been defined and will be simulated numerically using TRNSYS software. A comparative analysis of these different alternative versions will be conducted to determine the best configuration(s) of the GEOSOL process in terms of energy, economical and environmental performances. (author)
This brochure describes the strategy employed by the administration of Malaspina University--College in Nanaimo, British Columbia, to implement energy-efficient plans and integrating systems and plans that would allow the institution to consume less energy, fewer resources and improve the health and well-being of its students and staff. An assessment study to identify the most problematic areas, and to develop a prioritizing strategy for their replacement was the first step, followed by rigorous adherence to a 10- year cyclical replacement schedule. The program includes replacement of rooftop ventilation units, installation of high-performance glazing units to replace single-glazed windows, implementation of an Energy Management System to monitor heating, ventilating and air conditioning systems, and a Power Smart New Building Design and Building Improvements Program. The combined cost avoidance associated with these ...
This picture shows one of the 2 new cavities installed in 1978-1979. The main RF-system of the SPS comprises four cavities: two of 20 m length and two of 16.5 m length. They are all installed in one long straight section (LSS 3). These cavities are of the travelling-wave type operating at a centre frequency of 200.2 MHz. They are wideband, filling time about 700 ns and untuned. The power amplifiers, using tetrodes are installed in a surface building 200 m from the cavities. Initially only two cavities were installed, a third cavity was installed in 1978 and a forth one in 1979. The number of power amplifiers was also increased: to the first 2 MW plant a second 2 MW plant was added and by end 1979 there were 8 500 kW units combined in pairs to feed each of the 4 cavities with up to about 1 MW RF power, resulting in a total accelerating voltage of about 8 MV. See ...
Appendices to this summary consist of twelve individual status reports that will be available through the National Technical Information Service (NTIS) in the United States and of course limited copies will be available through NATO. The twelve report titles which are appendices to the summary are: (A) Status Report on the Limestone/Sludge Flue Gas Desulfurization Process; (B) Status Report on the Lime/Sludge Flue Gas Desulfurization Process; (C) Status Report on the Double Alkali/Sludge Flue Gas Desulfurization Process; (D) Status Report on the Sea Water Scrubbing Flue Gas Desulfurization Process; (E) Status Report on the Limestone/Gypsum Flue Gas Desulfurization Process; (F) Status Report on the Lime/Gypsum Flue Gas Desulfurization Process; (G) Status Report on the Double Alkali/Gypsum Flue Gas Desulfurization Process; (H) Status Report on ...
retirement of the Dean H. Mitchell Station Installation of three new flue gas desulfurization systems (FGD) at Schahfer 14, Schahfer 15, and Michigan City 12 Upgrades to...
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
This 2001 edition of the guide to UK renewable energy companies examines the geothermal heat pump sector, and discusses the technology involved, installations of geothermal heat pumps, the activity in the UK market with increased interest in UK geothermal heat pump products from abroad, and developments in the building sector. The UK government's increased support for the industry including its sponsorship of the Affordable Warmth programme, and the future potential of ground source systems are discussed.
This article described a full-scale green renovation project undertaken by a construction management firm in Newton, Massachusetts. Chapman Construction and Design began renovating its own office building in late 2007 and completed it in September 2008. The firm set out to achieve LEED Platinum certification from the United States Green Building Council. The project involved energy saving modifications to its mechanical systems; replacing plumbing fixtures with high efficiency alternatives to reduce water consumption by at least 40 per cent; installing skylights and additional windows to allow more natural light into the interior space; salvaging doors, lighting, metal studs and masonry whenever possible; and using sustainable products such as recyclable carpets, tiles and low-VOC paint. The main feature of the renovation was a new 47 kW (DC) photovoltaic (PV) solar power array installed on the rooftop. ...
The results have been presented of DC polarization and exposure investigations of alloy steels used as construction materials in flue gas desulphurization installations. on the base of analysis of composition of investigated steels and results of polarization studies, conditions have been discussed in which the pitting resistance equivalent (PRE) should be used. Among tested steels the significantly highest resistance to pitting corrosion is exhibited by 654SMO steel, classified as the super austenitic grade. (author). 14 refs, 3 figs, 2 tabs.
This paper summarizes the investigation of horizontal direction drilling and the subsequent experimental installation of a natural gas network in a suburb of Paris, France. Three aspects of drilling were studied prior to implementation: (1) reliability of the technique and quality of pipelaying to ensure long-term supply main operation; (2) ability to assess the successfulness of the work by assessing preliminary conditions; and (3) economonic viability. Measurement of tensile stress on polyethylene pipe during pulling and comparative accelerated aging tests on scratched pipe were performed. In the implementation phase, 300 meters of pipe were laid daily, by using three machines simultaneously, at a cost comparable to that of conventional techniques.
The basic principle of the green building philosophy is to design buildings that consider environmental performance. Residential and commercial buildings in Canada consume about 30 per cent of the total secondary energy use and are responsible for approximately 29 per cent of carbon dioxide equivalent greenhouse gas emissions and many other wastes. An optimization model was developed which minimizes life cycle cost and life cycle environmental impact. The model distinguishes different energy sources and incorporates their impacts, such as resource depletion, global warming and acidification. The model also considers design variables such as window type, orientation, building orientation, window-to-wall ratio, wall type and roof type. The model can be used to identify optimum green building designs for given conditions. The model uses expanded cumulative exergy ...
Often oil/gas and other hydrocarbons discovered and produced offshore are transported to onshore facilities via submarine pipelines. The route of such pipelines traverses through coastal/shore approach regions. For a rational/economic design, safe installation and subsequent operation it is of utmost importance to review, evaluate and finalize various environmental hazard such as winds, waves, currents, seabed topography, seabed and sub-bottom soils, seabed erosion and soil accretion. This paper addresses the above described environmental hazards, their assessment and techniques to prepare design parameters which must be used for stability analysis, installation methods, long term operation and maintenance for the shore approaches. Additionally, various proven pipeline installation and stabilization techniques for the shore approach region are detailed. As case histories, three approaches ...
The main objective of the present study is twofold: (i) to analyze thermal loads of the geothermally and passively heated solar greenhouses; and (ii) to investigate wind energy utilization in greenhouse heating which is modeled as a hybrid solar assisted geothermal heat pump and a small wind turbine system which is separately installed in the Solar Energy Institute of Ege University, Izmir, Turkey. The study shows 3.13% of the total yearly electricity energy consumption of the modeled system (3568 kWh) or 12.53% of the total yearly electricity energy consumptions of secondary water pumping, brine pumping, and fan coil (892 kWh) can be met by using small wind turbine system (SWTS) theoretically. According to this result, modeled passive solar pre heating technique and combined with geothermal heat pump system (GHPS) and SWTS can be economically preferable to the conventional space heating/cooling systems used in agricultural and residential ...
JRR-3 is a research reactor of 10 MWt output, which attained the criticality in 1962. All the design, manufacture, installation and others of this reactor were carried out by Japanese technologies, except the fuel and heavy water as the moderator and coolant, therefore it is nicknamed Home-made No.1 Reactor. Recently, due to the change in the state of utilizing research reactors and the rise of quality in the utilization, JRR-3 has become to be unable to meet sufficiently the needs of users. The plan of reconstructing the JRR-3 was considered under such situation, and in order to reuse the reactor building, the reactor proper is removed, and an entirely new, high performance, versatile reactor is to be constructed. In this paper, as to the removal works of the JRR-3 reactor proper, the method of execution, design, the execution of works and so on are outlined. The removal works of the reactor facilities were started in February, 1986. The ...
The assets that Citizen Potawatomi Nation holds were evaluated to help define the strengths and weaknesses to be used in pursuing economic prosperity. With this baseline assessment, a Planning Team will create a vision for the tribe to integrate into long-term energy and business strategies. Identification of energy efficiency devices, systems and technologies was made, and an estimation of cost benefits of the more promising ideas is submitted for possible inclusion into the final energy plan. Multiple energy resources and sources were identified and their attributes were assessed to determine the appropriateness of each. Methods of saving energy were evaluated and reported on and potential revenue-generating sources that specifically fit the tribe were identified and reported. A primary goal is to create long-term energy strategies to explore development of tribal utility options and analyze renewable energy and energy efficiency options. Associated goals are to consider exploring ...
Petropavlovsk-Kamchatky (P-K) city in Kamchatka, Russia is operating hot-water district heating using heavy oil boilers and waste hot water of thermal power plants as heat sources. Feasibility study was made on district heating using natural geothermal hot water and/or geothermal heat pump systems as heat sources of hot water supply for reduction of greenhouse effect gas emission. Among 3 areas including geothermal hot water, use of hot water in K area was impossible because of lower temperature and less spring water. Use of hot water in P and UP areas was impossible as primary hot water because of temperature drop to 64 degrees C during hot water supply toward P-K city. The building heating operation test was carried out using the geothermal heat pump system installed in a newly drilled heat exchange well of 100m deep. As a result, sufficient heat recovery was achieved for heating. If all of 49 boiler houses for heating ...
This paper is a quarterly report describing the use of a new soil gas collection device which allows the collection of soil gas in the field for later analysis in the laboratory. It describes the installation of this sampling device and the procedure for setting the probe, extraction of soil gas beneath the surface, and sealing of the soil gas for transport. The sites used for initial testing was the top of Yucca Mountain and Crystal Spring in Ash Meadows National Wildlife Refuge. The results from this initial test showed no volatile matter present in the soil at these locations.
Southern California Gas Co.`s (SoCalGas) Energy Resource Center (ERC) in Downey, Calif. is a 45,000 ft{sup 2} (4,181 m{sup 21}) conference and education center created to help energy decision-makers find the most energy-efficient, cost-effective and environment-sensitive solutions to their energy requirements. The center has 36,000 ft{sup 2} (3,344 m{sup 2}) of remodeled space and 9,000 ft{sup 2} (836 m{sup 2}) of new space, all designed to showcase the latest energy-efficient and environment-sensitive technologies. The building is one of the 25 buildings in the US to be designated as Energy Star Showcase buildings by the US Environmental Protection Agency.
The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))
Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma ...
The purpose of this solar energy project was to design, manufacture, install, maintain and evaluate solar heating systems in order to stimulate community acceptance of the practicality of solar applications, reduce non-renewable energy resource consumption, and decrease residential expenditures for energy. The project also provided skill training and experience for CETA employees in the design, manufacture, and installation of solar energy equipment systems. CDC's contract had four separate solar energy projects; namely: Domestic Water Heating Systems for four Single-Family Homes; Domestic Water Heating for an industrial building; Domestic Water Heating for a (4) unit apartment complex (includes (12) supplemental space heating units); and Integral Passive Water Heaters and Energy Conservation Devices for (8) one bedroom homes. CDC staff designed all solar systems and CETA trainees (County and City vocational ...
Rotex Inc. has designed and manufactured industrial sifting equipment since 1844. This site (an existing industrial facility) encompasses approximately 140,000 ft[sup 2] (13,006 m[sup 2]) of offices, R D shops, assembly and storage areas, as well as a large welding shop that was the main focus of this project. This facility consists of three separate buildings that are all connected and open to one another. The original building dates from 1908. The newest addition (32,400 ft[sup 2]; 3,010 m[sup 2]) was added in 1977, and is referred to as the 77 Building. This building was initially equipped with oil fired heating equipment due to the moratorium on new gas sales that was in effect at that time. This project was driven by the client's need to remove underground oil storage tanks to comply with environmental standards. This article describes the 77 ...
To realise the Dutch objectives of energy saving and emission reductions in the built environment, the use of 'Low Valued Energy' will be necessary in the future. Low Valued Energy is available from residual, ambient heat and renewable sources. Using Low Valued Energy for space heating in commercial and residential buildings requires adjusting the design of the installations, i.e. lowering the design supply temperature of the heating system from 90C to 55C or less. Appropriate heat distribution systems, e.g. floor or wall heating and radiators, have a life cycle of 40 to 50 years. The application (on a large scale in buildings), however, requires an enormous change in the installation and building branch. To enable the application of low temperature sources in the future, the building and installation designs should be ...
Sensors installed at a telephone office building in Neenah, WI, continuously monitor 24 parameters related to the operation of the building's heating, ventilating, and air conditioning (HVAC) system. This data is stored in a dedicated minicomputer and can be retrieved, in various formats, for subsequent analyses. For more than a year, we have measured indoor and outdoor concentrations of both fine and coarse airborne particles, their chemical constituents, and volatile organic compounds at this same location. Using this data, we have examined the composition of the indoor air as it correlates to the composition of the outdoor air and the various HVAC operating parameters. The steady-state indoor concentrations of the particles, particulate constituents, and organic vapors can be explained in the context of a mass balance model. This model can also be used to calculate the rate at which selected chemicals are ...
Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the ...
An assessment study of the sea water scrubbing process for flue gas desulfurization has been made by SINTEF. This project has been financially supported by the Royal Ministry of Environment of Norway. The study is based on three FGD-units which are installed at three oil-fired, industrial boilers respectively with a maximum continuous heat input of 130 MW (27 MW + 2x51.5 MW) corresponding to approximately 50 MWE (10 MWE + 2x20 MWE) generating capacity for a power plant having a net efficiency of 38%.
Korea Electric Power Corporation (Kepco) of South Korea has awarded Asea Brown Boveri Switzerland, a member of the ABB Group, a contract to supply the main equipment for two gas-fired combined-cycle power stations. News of the contract followed an announcement last year that Kepco will build a series of gas-fired power stations in the early 1990s to supply electricity to new housing and commercial areas being built in the Seoul-Incheon connurbation. (author).
Full text: Chemical-technology approaches allowing to intensification the prevention processes of gas hydrates formation at motion of gas-liquid stream of natural gas in system natural gas well - gas wire have been worked up. Technological regimes of treatment of gas stream have been determined. Linear correlation dependences inhibitor electrolytes contained hydrated ions with different ion radii and charges of subgroups of alkali elements with one - type electron configuration were obtained. Important physico-chemical parameters of electrolytes have been determined: activity; coefficients of activity, viscosity, diffusion; density; heat capacity; heat conductivity; surface tension and freezing-point. The features of continuous influence of inhibitory factors on process of gas flow at low temperatures and relatively high pressure differences ...
This study is one element of a larger engineering study effort by WHC to examine the feasibility of irradiated fuel and sludge consolidation in the KW Basin in response to TPA Milestone (target date) M-34-00-T03. The study concludes that up to 11,500 fuel storage canisters could be accommodated in the KW Basin with modifications. These modifications would include provisions for multi-tiered canister storage involving the fabrication and installation of new storage racks and installation of additional decay heat removal systems for control of basin water temperature. The ability of existing systems to control radionuclide concentrations in the basin water is examined. The study discusses requirements for spent nuclear fuel inventory given the proposed multi-tiered storage arrangement, the impact of the consolidated mass on the KW Basin structure, and criticality issues associated with multi-tiered storage.
This research report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that examined the feasibility of setting up 'MINERGIE' low-energy-consumption module standards for the production of heat in small residential buildings. The aims of the standards and the basic idea behind the MINERGIE-modules are discussed. The concepts of the modules for heat pumps and wood-fired heating systems and their combination with solar installations are examined, as are their areas of application. The requirements placed on the modules are listed. System concepts, including simple schematics for typical installations, are presented for wood-log, wood-chippings and pellets-fired systems as well as for ground-loop and air-water heat pump systems as well as their solar-aided counterparts. The results of cost-benefit analyses are presented and questions regarding system guarantee and liability are ...
The superconducting magnets and associated cryogenic components in A-sector represent the initial phase of installation of the Fermilab superconducting accelerator, designed to accelerate proton beams to energies of 1 TeV. Installation of the magnets, comprising one-eighth of the ring, was completed in December, 1981. Cooldown and power tests took place in the first half of 1982, concurrent with main ring use for 400 GeV high energy physics. The tests described in this paper involved 151 cryogenic components in the tunnel: 94 dipoles, 24 quadrupoles, 25 spool pieces, 3 feed cans, 4 turn-around boxes and 1 bypass. Refrigeration was supplied by three satellite refrigerators, the Central Helium Liquefier, and two compressor buildings. The magnets were powered by a single power supply.
Good indoor air quality and thermal comfort, as well as low energy consumption, were achieved in an environment friendly experimental METOP-office building in Espoo, Finland. The consumption of heating and cooling energy was minimized by installation of energy-efficient windows, good CFC-free thermal insulation of the building envelope, the individually-controlled ventilation and room temperatures, heat recovery and energy-storing structures. According to the study carried out in 1990-1993, the heating energy was 13 kWh/m{sup 3}, 60% lower than the average consumption. The index of the satisfaction of thermal comfort was over 90%. Concentrations of all the measured indoor air pollutants were low. Ventilation rates could be chosen in each office room from 10 to 40 dm{sup 3}/s. The noise level of the ventilation system was low and the lighting level was pleasant. (author)
This article comments on the fact that there are only 17 energy-from-waste installations in operation in the U.S. and in this respect it lags behind other industrialized nations. Explanations for this gap include the relatively inexpensive garbage disposal as landfill, operating difficulties of some early plants and the high cost of building such facilities. There has been a recent push to build resource-recovery plants and it is believed that chemical companies will probably buy energy products from such plants. Hooker Chemical Co's new energy-from-waste plant at Niagra Falls, N.Y. is described, other companies involved in resource-recovery projects are mentioned, and it is hoped that more companies will invest in such plants.
Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...
This is the first of a series of monthly reports summarizing the status of the work of the National Accelerator Laboratory. This first report will cover developments since the publication of the Design Report in January. Authorization hearings were held before the Joint Committee on Atomic Energy on February 21, 1968. Dr. Wilson described the plans and designs of the Laboratory. The present plan of the Laboratory is that the Village of Weston will be utilized for office, laboratory, and shop space during construction. The Laboratory business office is already occupying several houses. The linac section is occupying three houses for offices and construction of an 8,000 sq ft laboratory building for linac work is almost complete. Another house is being used and a 4,500 sq ft inflatable building is being constructed for model-magnet and vacuum testing. Other temporary buildings will be constructed for use by other sections. We ...
Due to the general market conditions, the construction of steam turbines was greatly reduced in 1987. As in 1986, it came to a downward movement. This situation will heighten in the coming years. The exploitation of devices, which are available by way of the development of EDP in computation, construction, production and operation, leads to considerable improvements. These improvements can only be employed gradually, due to the reduction in production. However, technological progress can be used economically in part in the restoration of old installations. Here turbine construction, the thermodynamical interpretation of gas and steam turbines, developments in the field of conduction technology, piping and materials are described. Also improvements in operation security and operation supervision of the installations is treated, as well as service and maintenance of the plants. (BR) With 131 refs.
Many rural industries generate amounts of biomass waste, such as rice husks, sawdust, wood chips, nutshells and plant stalks that represent a substantial energy resource. However, most often these biomass wastes are not utilized and are dumped or burned in the open. This paper will show the whole project cycle of an installation and commissioning of a thermal configuration of a BG-Systems in Indonesia. These projects highlight the economic, operational and environmental benefits of the BG-Systems. BG-Systems are small fixed-bed downdraft gasifier systems being marketed by BG Technologies that convert biomass into a producer gas that is essentially free of tars and can be used reliably in a diesel engine or thermal combustor. (author)
One year of research on validating the performance of the Cable Monitoring and Rating System (CMARS) is reported. The performance testing was conducted on underground 230-kV and 345-kV pipe type cable circuits owned by the New Jersey Public Service Electric and Gas Co. Laser temperature monitoring systems and a data acquisition system were installed. Software installation and development is discussed. The CMARS testing program is described. (LCL)
A survey has been made in relation with the improvement project intended of energy conservation, and reduction of global warming gas emission at the Bobovdol thermal power plant located in the suburb of Sofia, the capital of the Republic of Bulgaria. The existing Bobovdol power plant having a total capacity of 630 MW with three generators is a coal burning thermal power plant having been used already for 23 to 27 years, hence over-aged. The survey has discussed an improvement project of scrap-and-build type to make the plant a high-efficiency gas combined cycle power plant using gas turbines. The project calls for building 210-MW gas combined power generation facilities having 70-MW gas turbines, one each in three stages in 2007, 2012 and 2017. As a result of the discussions, the fuel consumption reducing rate was found to reach 37.99%, ...
This paper describes the field performance of air conditioning with an energy pile system, which was applied to the pile foundations of an actual building for the purpose of reducing the cost of the underground heat exchanger. First, the building for both office and residential use, for which a space heating and cooling system using friction piles was installed, was built in Sapporo in December 2000. Second, three tests were carried out to specify the design of a heat exchanger inside the pile, and a U-tube type underground heat exchanger was adopted from the viewpoint of energy efficiency and installation costs. Long-term space heating operation measurements indicated that the seasonal average temperatures of brine returning from the underground and pile surfaces were 2.4 and 6.7 deg C, respectively. The average coefficient of performance for space heating was quite high at 3.9, and the seasonal ...
The High Exposure Facility is a collimated high-level gamma irradiator that is located in the basement of the 318 building. It was custom developed by PNNL back in 1982 to meet the needs for high range radiological instrument calibrations and dosimeter irradiations. At the time no commercially available product existed that could create exposure rates up to 20,000 R/h. This document is intended to pass on the design criteria that was employed to create this unique facility, while maintaining compliance with ANSI N543-1974, "General Safety Standard for Installations Using Non-Medical X-Ray and Sealed Gamma-Ray Sources, Energies up to 10 MeV."
Gas transmission pipelines are susceptible to both internal (gas side) and external (soil side) corrosion attack. Internal corrosion is caused by the presence of salt laden moisture, CO{sub 2}, H{sub 2}S, and perhaps O{sub 2} in the natural gas. Internal corrosion usually manifests itself as general corrosion. However, the presence of chlorides in entrained water also can lead to pitting corrosion damage. The electrochemical noise technique can differentiate general from localized corrosion and provide estimates of corrosion rates without external perturbation of the corroding system. It is increasingly being applied to field and industrial installations for in situ corrosion monitoring. It has been used here to determine its suitability for monitoring internal and external corrosion damage on gas transmission pipelines. Corrosion measurements were made in three types of ...
A self contained continuous power generation system as described at INTELEC 1979, was successfully commissioned and put into service in a major communications centre at Cardiff in Wales. The objective was to provide all telecommunications equipment and electrical building engineering services from a dual fuel enginegenerating plant, and to recover waste heat energy to heat or cool the building. The plant, which is fully automatic, comprises five 1300kW engines using natural gas or diesel oil, and associated waste heat boiler and chiller systems. This paper reviews the functioning of the plant during its first three years of operation.
The purpose of this project was to build a long-range, parallel hybrid gas/electric vehicle capable of driving beyond the communter capabilities of series hybrid vehicles. It was envisioned that since the gas engine would be able to independently propel the car when needed and that the electric motor would be capable of doing the same, then you have a very desirable situation where this car can operate much more cheaply on electricity for the short distance runs under approximately 60 miles and also be able to propel the vehicle via the gas engine on the long-distance trips. During the time the car would be operating in the gas engine mode, it would be also recharging the 16 deep cycle batteries via the electric motor now being used as a generator. Then, even on long-distance trips, the electric motor could be used, after having been fully or partially recharged, to even further ...
Asphalt emulsions were evaluated as a means to immobilize radiological contaminants deposited on urban surfaces after a dirty bomb attack. Contaminated surfaces would be sprayed with thin coatings of asphalt emulsion to encapsulate the radioactive particles until the site can be safely remediated. This research investigated applications of an asphalt emulsion (Topein C, Encapco Technologies, LLC, Napa, CA) to treat (zero-valent) iron, lead, and uranium powders on various building material surfaces. Initial studies found that some of the building materials (limestone, concrete, and metal) reacted with the emulsion producing gas bubbles, which formed 0.001 to 1 cm vesicles in the cured asphalt emulsion. These vesicles, however, did not expose the building material surface, and the reaction a...
This final report for the Swiss Federal Office of Energy (SFOE) examines a project that aimed to define standard solutions for use in buildings built to meet Minergie low energy consumption standards. These standard solutions are to provide a way of meeting Minergie standards in an easy way and thus further the use of the standard and also assure quality at the same time. The report describes how the solutions were developed on the basis of a selection of existing Minergie buildings. For various combinations of heating systems - wood, wood/solar, heat pumps (brine-water and air-water), gas/solar and oil/solar - the appropriate U-values for various building elements are listed. The resulting Minergie forms and guides are listed.
The Y2K problem may impact on nuclear installations in a number of ways because embedded systems are used in nuclear routine operation, monitoring and control system. The very simplest embedded systems are capable of performing only a single function or set of functions to meet a single predetermined purpose. In more complex systems the functioning of the embedded system is determined by an application program that enables the embedded system to be used for a particular purpose in a specific application. The simplest devices consist of a single microprocessor which may itself be packaged with other chips in a hybrid system or Application Specific Integrated Circuit (ASIC). Its input comes from a detector or sensor and its output goes to a switch or activator which may start or stop the operation of a positioning motors or, by operating a valve, may control the flow of cooling system to reactor core. Embedded systems in our organization are also be found in Batan ...
Looking at some of the national and international developments in hydrogen technology it becomes clear which important contributions the hydrogen technology oriented activities of the EU have helped to prepare and trigger: (a) Transport Energy Strategy (TES): This initiative of 7 major German automobile and mineral oilcompanies is aimed at an industrial consensus on one or two gasoline alternative fuels, which are to be presented to the German Ministry of Transport. An intermediate trend is that hydrogen may become the fuel of choice. (b) BMW: The Bayerischen Motorenwerke have already very early exposed themselves to the vehicle and component development of hydrogen as a vehicle fuel, focussing on a strategy from CNG to LNG and LH{sub 2}. (c) Opel and GM: Opel has recently announced they have chosen hydrogen as the primary long term fuel for their fuel cell vehicles to be commercialized starting in 2004. (d) CFCP: The California Fuel Cell Partnership with partners from industry and ...
Preliminary results from a large-scale testbed of advanced lighting control technologies at the Phillip Burton Federal Building at 450 Golden Gate Ave. in San Francisco are presented. The first year objective of this project is to determine the sustainable energy savings and cost-effectiveness of different lighting control technologies compared to a portion of the building where only minimal controls are installed. The paper presents the analyzed results from six months of tests focused on accurately characterizing the energy savings potential of one type of daylight-linked lighting controls compared to the lighting in similar open-planned areas without dimming controls. After analyzing a half year;s data, we determined that the annual energy savings for this type of daylight- linked controls was 41% and 30% for the outer rows of lights on the South and North sides of the building, respectively. The ...
The European demonstration project Hip Hip (house integrated photovoltaic high-tech in public) led the French photovoltaic market to reach a level comparable to those of the other European countries in terms of relevance of implemented solutions and costs. This document presents the best realizations and the experience gained through the Hip Hip project. Its aim is to convince the designers and managers of building projects of the advantages of photovoltaic installations integrated to the structure and connected to the power distribution grid: 1 - presentation of the technology; 2 - status of the Hip Hip demonstration project (goals, results: main innovations and impact on the French market); 3 - different possibilities of integration to the building structure; 4 - examples of projects realized in France in the framework of the Hip Hip project: integration in glass roof, frontage, added elements, fitting on roofs. (J.S.)
A solar-powered adsorption air-conditioning system was designed and installed in the green building of Shanghai Research Institute of Building Science. The system contained 150 m{sup 2} solar collectors and two adsorption chillers with nominal refrigeration capacity of 8.5 kW. Based on performance characteristics of the adsorption chiller, the operation mode of the solar-powered air-conditioning system was optimized by maintaining a phase shift of 540 s between the two adsorption chillers. Thereafter, the whole system realized stable operation by the balance of heat consumption and refrigeration output. From June to August of 2005, the solar-powered air-conditioning system continuously ran between 9:00 and 17:00. The operation performance of the system under representative working condition showed that the average refrigeration output of the solar-powered air-conditioning system was 15.3 kW during an 8 h operation and the ...
Tarapur Atomic Power Station Unit-4 was made critical on 6th March 2005. Since radiation field builds up with the power level due to formation of fission products and activation products in different systems. Radiation dose rates were recorded from different areas using Area Radiation Monitors (ARMs) installed at different areas. These monitors are connected to Radiation Data Acquisition System (RADAS). The trend of radiation field build-up was also analyzed by making survey of different plant areas at various power levels and comparison was made with RADAS readings. The results obtained were compared with 220 MWe dose rates. This study discusses about the dose rates observed at accessible area, shut down accessible area and hotspots observed during the early stage of operation of the reactor. The attempt was also made to find the contributing factors of the high dose rates. It was found that the finding of the study was ...
This report presented some quick facts about oil and gas pipelines in Turkey and presented opportunities for trade. The key players and customers in the oil and gas sector were described along with an export check list. Turkey is looking into becoming an energy bridge between oil and gas producing countries in the Middle East, Central Asia and Europe. The oil and gas sectors are dominated by the Turkish Petroleum Corporation, a public enterprise dealing with exploration and production, and the State Pipeline Corporation which deals with energy transmission. They are also the key buyers of oil and gas equipment in Turkey. There are several pipelines connecting countries bordering the Caspian Sea. Opportunities exist in the areas of engineering consulting as well as contracting services for oil and gas pipeline transmission and distribution. Other opportunities ...
The possibility of employing a number of adsorbents (polyphenylquinoxaline, Tenax GC, Carbopak C, graphitized thermal carbon black, silica gels modified with pyrocarbon or hexamethyldisilazane) for the trapping of organic traces from air has been investigated. Adsorption capacities of these adsorbents with respect to a number of volatiles released from certain plastics used as building material (polyvinylchloride, Relin, Acronal, etc.) have been measured. A number of the volatiles were identified by gas chromatography - mass-spectrometry after trapping on the adsorbents investigated. Chromatographic separation after trapping on the adsorbents was carried out on wall-coated open-tubular capillary columns as well as in capillary columns packed with graphitized thermal carbon black.
This article reports on the world's first gas turbine to top 40% thermal efficiency in simple cycle and is now operating commercially as part of a natural-gas-fired combined-cycle cogeneration (CC) plant serving the Ottawa Health Sciences Center, Ottawa, Ont, Canada. Owned and operated by TransAlta Energy Corp, Calgary, Alta, the CC plant supplies steam and hot and chilled water to the health center and another thermal user while the electricity is sold to Ontario Hydro. Part of the project included the conversion of 15-psig steam-carrying equipment to hot-water service. Commercial success of this installation heralds a new era in the application of efficient gas turbines for power generation.
As part of three ongoing research projects, the Gas Research Institute (GRI) is studying the natural gas industry`s impacts on wetlands and how to manage operations so that impacts can be minimized or eliminated. The objective of the first project is to gain a better understanding of the causes and processes of wetland loss in the Louisiana deltaic plain and what role gas pipeline canals play in wetland loss. On the basis of information gathered from the first projects, management and mitigation implications for pipeline construction and maintenance will be evaluated. The objective of the second project is to assess the floral and faunal communities on existing rights-of-way (ROWs) that pass through numerous types of wetlands across the United States. The emphasis of the project is on pipelines that were installed within the past five years. The objective of the third project is to evaluate the ...
This paper consists of two parts. Part 1 deals with the thermodynamic and thermoeconomic methodology of a trigeneration (TRIGEN) system with a rated output of 6.5 MW gas-diesel engine while the application of the methodology is presented in Part 2. The system has been installed in the Eskisehir Industry Estate Zone in Turkey. Thermodynamic methodology includes the relations and performance parameters for energy and exergy analysis, while thermoeconomic methodology covers the cost balance relations, cost of products and thermodynamic inefficiencies, relative cost difference and exergoeconomic factor. (author)
There is very little quantitative documentation of actual improvements resulting from the installation of new general ventilation systems in industrial settings. Therefore the performance of the common mixing design principle was compared to the displacement design principle by means of an intervention study in a workshop (V = 12,000 m[sup 3]), where thermoplastics were moulded. An experimental signal-response tracer gas technique was used. In terms of supplying fresh air to the zone of occupancy the displacement system was better than the mixing system by a factor of 2. In terms of the exposure level to a simulated contaminant (tracer gas) the displacement system was better by a factor 1.5-18. (author)
This paper gives details of the development of the Wartsila 32DF duel-fuel lean-burn engine that can burn liquid or gaseous fuels, and reports on the installation of four of the engines in Turkey. The combustion process, and the design of the gas admission, pilot fuel, cylinder control, air-fuel control, and engine control and monitoring systems are described. The advantages of the engine are discussed.
Biogas-Compost Technology is being experimented in several research centers in Burkina Faso. This technology is about putting up prototypes in order to allow the use of fermentation products. Research on how to operate such technology, no matter small irrigation or domestic energy, has enabled the evaluation of the biogas-compost production and consumption. The implementation of such technology has made possible the agronomic valorization of fermentation residues, the improvement of the process of gas production, and the decrease of installation costs.
General trends of developing hydrogen power engineering and technology in Ukraine are considered. Based on a general level of power consumption and real opportunities for hydrogen production, a conclusion is derived that there are possibilities in the near future to partially replace conventional hydrocarbon fuels by hydrogen. Besides, developed technologies for burning hydrogenous gases and hydrogen-fuel systems when applied to transport installations allow one to improve essentially their power and ecological characteristics. 5 refs.
This paper presents a technical feasibility study project for the large scale rooftop photovoltaics (PV) grid connected system at Charoenphol-Rama I green building super store of TESCO LOTUS (TL) in Thailand. The objective of this project is (i) to study the technical feasibility of installation 350 kWp PV systems on the top of the roof in this site (ii) and to determine the energy produce from this system. The technical factors are examined using a computerized PVS 2000 simulation and assessment tool. This super store building located in Bangkok, with latitude 14 N, longitude 100 E and the building direction is 16 from North direction. The building roof area is 14,000 m2; with 3 degree face East and 3 degree face West pitch. Average daily solar energy in this area is approximately 5.0 kWh. The study team for this project consists of educational institution as School of Renewable ...
Using an economic perspective, it is possible to make a case for green buildings and green development practices by placing emphasis on Energy Efficiency and Environmental Design. Several case studies have demonstrated that green buildings save money through reduced consumption of natural resources, electricity and gas both at the building site and at the source of energy. Sound environmental practices and energy efficiency measures improve the environmental conditions throughout the state by reducing power plant emissions and reducing operations and maintenance budgets in the state. The author presented a case study where a green development project was guided and monitored using the Environmental Performance Rating System called Leadership in Energy and Environmental Design (LEED), version 2.0. The work was registered to achieve LEED certification. A brief study on current construction related costs ...
Papers are presented under 38 symposia. Subjects included reinforced concrete, protective coatings and linings, cathodic/anodic protection, chemical cleaning of boilers, managing corrosion with plastics, water treatment, HRSG boiler tube failure analysis, corrosion in oil and gas production, corrosion in petroleum refining and gas, processing, pipelines and tanks, high temperature materials, chemical process industry, aerospace equipment, materials technology developments for incinerators and waste fuel-fired processors, materials and corrosion in fossil-fuels conversion and combustion, corrosion in nuclear systems, marine corrosion, building systems, corrosion mechanisms, corrosion inhibitors and corrosion monitoring and measurement.
... Carbon capture and storage Waste Prevention and Recycling EU clean air strategy Environmental liability: Applying the 'polluter pays' principle What goes around ...comes around: Recycling and climate change Behind closed doors: Air quality in buildings Keeping cool with refrigerants: The F-gas review Regions fighting climate ...
Amidst the explosion of greenfield natural gas-fired combined-cycle plant development, opportunities still exist for valuable plant repowering and retrofits by taking advantages of unique technical and market conditions. One of the projects discussed is the rebuilding of the coal-fired Hawthorne unit 5 damaged by a boiler explosion. 3 tabs., 5 photos.
This paper describes the safety gas management system utilizing public telephone cables. Buyo Gas Co., Ltd. has installed about 100 governors for exclusive-use or use in the districts to control the gas supply to the consumers. A gas safety management system has been developed. This system consists of a pressure sensor, the terminals of gas leak alarms, and their masters. The features lie in that the system can utilize public cables, is operative at interruption of power service, can correspond to emergency situations, serves to save the cost, and can display the data constantly. For electric facilities in a governor room and the NTT cable service work, sufficient agreement with the possessor is required. In the case of non-utility electric facilities, some restrictions are imposed on the cable work for laying from privately-owned transformers, etc. Insurance ...
Externally Fired Combined Cycles (EFCCs) can increase the amount of electricity produced from ash bearing fuels up to 40%, with overall powerplant efficiencies in excess of 45%. Achieving such high efficiencies requires high temperature-high pressure air heaters capable of driving modern gas turbines from gas streams containing the products of coal combustion. A pilot plant has been constructed in Kennebunk, Maine to provide proof of concept and evaluation of system components. Tests using pulverized Western Pennsylvania bituminous coal have been carried out since April, 1995. The ceramic air heater extracts energy from the products of coal combustion to power a gas turbine. This air heater has operated at gas inlet temperatures over 1,095 C and pressures over 7.0 atm without damage to the ceramic tube string components. Stable gas turbine operation has been achieved with energy ...
Oil and gas production and processing operations sometimes cause naturally occurring radioactive materials (NORM) to accumulate at elevated concentrations in by-product waste streams. The sources of most of the radioactivity are isotopes of "2"3"8U and "2"3"2Th series, which are naturally present in the subsurface formations from which oil and gas are produced. NORM waste may cause problems in the operations of installations by plugging perforations, clogging tubular and valves then restricting flow. Therefore, plants or equipment have to be refurbished and decontaminated before reuse to avoid radioactive waste or surface contaminated object. There are two options for safe disposal of scale and sludge produced from NORM Descaling Facility : 1- Injection into an abandoned production well. 2- The construction of a near surface depository. These options are assumed to be environmental friendly disposal options. (author)
A negative public reaction is expected to oppose plans of the British energy industry to take valuable sites for industrial and commercial projects on the ground that government demand forecasts are too high and that they downplay conservation. The United Kingdom (UK) Department of Energy points out that public inquiry always accompanies energy installations and defends the projections made by producers even though each study emphasizes the demand for its own form of energy. At issue are plans to open 150 opencast coal mines a year to compensate for diminishing oil and gas supplies, onshore drilling by oil and gas exploration teams on nearly 50,000 km/sup 2/, and sites required for onshore pipelines, synthetic natural gas facilities, pumped storage plants, and nuclear power stations and waste management. The sites under discussion raise aesthetic and ecological concerns. (DCK)
This publication contains the Ordinance on Heating Costs, the Ordinance on Heating Installations, and the 1st Federal Ordinance on Emission Control (BImSchV) concerning Small-Scale Furnaces, in each case with notes and explanations. All these ordinances aim at reducing energy consumption in connection with heating; the 1st BImSchV also at air pollution abatement by lowering the permissible limiting values for soot and flue gas. The three ordinances also apply to housing property. (HSCH).
The regular occurrence of large-scale earthquakes in Japan necessitates the use of earthquake disaster prevention systems that focus on gathering damage information on gas supply facilities immediately after an earthquake strikes and minimizing the damage. This paper discussed the development of an earthquake damage estimation system for city gas pipelines that can show damage information in real-time by using earthquake records obtained from densely deployed earthquake observation networks and the most advanced telecommunication and information technologies. The paper summarized the earthquake damage estimation system (EDES) and Toho Gas disaster prevention measures. Specific topics that were discussed included the Toho Gas supply method; earthquake countermeasures; construction of computer systems; normal and emergency operation of EDES; and verification of functions in actual earthquakes. It was ...
The main objective of the present study is to investigate Turkey's natural gas (NG) demand and supplies by giving the structure of the Turkish gas industry, NG pricing policy, and NG agreements. Turkey began to import NG from Russia in 1987 under a contract that provided for the delivery of 6 billion cubic meters annually (Bcma) for 25 years. The first contract, signed in 1988, stipulates delivery of 2 Bcma over a 20-yr period. The build-up of the Turkish gas market started by introducing gas in power generation in 1987 and in fertilizer production in 1988. Later contracts provide for total imports of 4 Bcma from the late 1990s. NG sales started at 0.5 Bcm in 1987 and reached to around 16 Bcm in 2001. Turkish NG demand is projected to increase extremely rapidly in coming years, with the prime consumers expected to be NG-fired electric power plants and industrial users. (author)
There are several concerns which bring to consider natural gas as a viable alternative to liquid fuels in transport. First, natural gas allows the curbing of global pollution in this steadily growing industry. Indeed, decoupling greenhouse gas emissions from transport growth has become a major issue in tackling climate change. Second, a more extensive use of natural gas would relieve city air quality, which is presently at levels harmful of human health. Nonetheless, this is just one side of the coin. The other side entails building a refuelling station network, and this carries financial requirements. The financing fraction holds a pivotal role in deciding whether natural gas for automotive purposes is an efficient solution. The final aim of this work is, therefore, to compare the natural gas advantages, stemming from avoided global and ...
In front of the risks linked with the increase of the greenhouse gas emissions in the atmosphere, the decision makers must take into consideration first, the scientific advice of climatic change experts, and second, the considerable inertia of the climatic system. Thus, any action implemented so far will have an impact all along the 21. century and later whatever the future human activities. The aim of this memento is to sensibilize the decision makers about the possible consequences of their choice in terms of volume of greenhouse gases and of medium- and long-term evolution: 1 - stakes, role of local decision-makers (greenhouse effect and climatic change, France's international commitment, stakes, liabilities of local decision makers, decentralization laws, local plans of fight against greenhouse effect, public information and dialogue); 2 - urbanism and transports (urban displacements, alternatives to individual cars, collective transportation systems, ...
There is a renewed interest in straight wing vertical axis wind turbines (SW-VAWT) which are usually installed on the roofs of high buildings in cities, urban areas and high mountain areas for independent electric power supply. SW-VAWTs have the advantages of simple design and low cost, as well as wind direction independence compared to the horizontal system. However, when SW-VAWTs are installed in cold regions, ice, snow and other attachments can affect its performance. In this study, clay was attached to the leading edge of the blade surface to determine how the performance of SW-VAWTs are affected by the mechanism of icing. Wind tunnel tests were used to study the rotational performance and power performance of the turbine blades. Icing prevention was also investigated. The attachment of clay on the leading edge of blade surface made the rotational performance of the SW-VAWT worse. The attachment of clay on the leading ...
Norway is a member of Annex 29, 'Ground-Source Heat Pump Systems Overcoming Technical and Market Barriers' (2004-2006), organized under the umbrella of the International Energy Agency (IEA) and the IEA Heat Pump Programme (HPP). The 7 participating countries are Austria (Operating Agent), Canada, Japan, Norway, Spain, Sweden and the USA. The Norwegian participation is financed by ENOVA SF, and SINTEF Energy Research is responsible for planning and carrying out the Norwegian activities. This report provides a status for ground-source heat pump (GSHP) systems in Norway with regard to state-of-the-art technology, installation examples, geological data, costs and market opportunities. A Norwegian Internet home page for ground-source heat pump systems (www.energy.sintef.no/prosjekt/Annex29) is also presented. GSHP systems in Norway are classified as direct systems (groundwater and soil/ground) and indirect closed-loop systems (vertical-rock and horizontal-soil/ground). ...
A glovebox was designed, fabricated, and mocked-up for the WIPP Gas Generation Experiments (GGE) being conducted at ANL-W. GGE will determine the gas generation rates from materials in contact handled transuranic waste at likely long term repository temperature and pressure conditions. Since the customer`s schedule did not permit time for performing R&D of the support systems, designing the glovebox, and fabricating the glovebox in a serial fashion, a parallel approach was undertaken. As R&D of the sampling system and other support systems was initiated, a specification was written concurrently for contracting a manufacturer to design and build the glovebox and support equipment. The contractor understood that the R&D being performed at ANL-W would add additional functional requirements to the glovebox design. Initially, the contractor had sufficient information to design the glovebox shell. Once the shell ...
A lower energy efficiency standard for buildings (EPC) can have a negative impact on thermal comfort and indoor air quality. Cooperation and integrated design are preconditions for a correct use, installation and maintenance of heating and ventilation systems in buildings. [Dutch] Er komt steeds meer kritiek op de wijze waarop in ons land woningen en gebouwen worden gebouwd. Op dit moment is het vooral woonhuisventilatie waar veel om te doen is. Van beleidsmakers tot aannemers en van Consumentenbond tot gezondheidsdiensten; iedereen vraagt zich af of we met vergaande isolatie onze woningen en gebouwen nog wel leefbaar houden. In dit artikel wordt een pleidooi gehouden voor onderlinge samenwerking en integraal ontwerp als randvoorwaarden voor een goede toepassing, installatie en onderhoud van verwarmings- en ventilatiesystemen in gebouwen.
Recent developments in heat pump technology have made geothermal-based heat exchange systems particularly well-suited for the heating and cooling needs of buildings even in cold climates. The principles of geothermally-coupled heat pump heating and cooling systems were presented. Results of an in-situ study conducted by Hydro-Quebec on the efficiency of the geothermal heat pump system installed at the Saint-Hyacinthe professional school were summarized. This investigation was meant to be a case study of the applicability of these new technologies to the needs of the Quebec market. After the first year of service, the Saint-Hyacinthe system clearly demonstrated its cost effectiveness over conventional systems. It was predicted that geothermal heat pump systems will gain in popularity in Quebec because they can fully meet the heating and cooling needs of public buildings at considerable cost reductions, besides offering ...
In this paper, we define, design and test a radiation tolerant autonomous monitoring tool for nuclear embedded applications. The goal of the instrumentation system was to record the values of some parameters such as dose, temperature or vibrations appearing inside the containment building of nuclear power plants. The knowledge of these parameters will be a good help for predictive maintenance of the power plant components. For the design of the monitoring tool, we rely on commercial-off-the-shelf (COTS) low power electronic components to use battery-supplied power. A large amount of components starting from discrete transistors or logic units to memories and micro-controllers was associated to define and design a prototype. We then confirm the environment conditions tolerance estimated to up to 2 kGy of total dose and 80 C for temperature by on-line irradiation experiments for individual components and functions and prototypes. Two different sets of about 60 ...
The demand for high-quality fibres and shives from hemp and flax as an alternative raw material for the automotive and building industry is increasing. Fibres are used primarily for composite reinforcement instead of synthetic fibres. Shives are used for animal bedding, but processing trials in wood industry for the production of low weight particle boards from shives are also very promising. Fibre producers require experience in cultivation and harvesting as well as modern processing technologies in order to supply flax fibres or shives at competitive prices under the changing conditions of international raw material markets. A complete processing line has been developed, installed and tested at the Leibniz Institute for Agricultural Engineering (ATB) to study all the processing stages of fibre production. The new ATB line can produce high quality fibres and shives from retted and unretted hemp, flax and oilseed flax straw without technical ...
This report addresses a Los Alamos National Laboratory (LANL) proposal to build a pulsed neutron source for simulating nuclear-weapons effects. A point design for the pulsed neutron facility was initiated early in FY94 after hosting a Defense Nuclear Agency (DNA) panel review and after subsequently visiting several potential clients and users. The technical and facility designs contained herein fulfill the Statement of Work (SOW) agreed upon by LANL and DNA. However, our point designs and parametric studies identify a unique, cost-effective, above-ground capability for neutron nuclear-weapons-effects studies at threat levels. This capability builds on existing capital installations and infrastructure at LANL. We believe that it is appropriate for us, together with the DNA, to return to the user community and ask for their comments and critiques. We also realize that the requirements of last year have changed significantly. ...
The first U.S. demonstration of the NGK sodium/sulfur battery technology was launched in August 2002 when a prototype system was installed at a commercial office building in Gahanna, Ohio. American Electric Power served as the host utility that provided the office space and technical support throughout the project. The system was used to both reduce demand peaks (peak-shaving operation) and to mitigate grid power disturbances (power quality operation) at the demonstration site. This report documents the results of the demonstration, provides an economic analysis of a commercial sodium/sulfur battery energy storage system at a typical site, and describes a side-by-side demonstration of the capabilities of the sodium/sulfur battery system, a lead-acid battery system, and a flywheel-based energy storage system in a power quality application.
A compact and supersensitive device that can rapidly detect minute trace vapors from concealed explosives has been developed by scientists at Oak Ridge National Laboratory (ORNL). The new explosives sensor can detect and chemically identify organic nitrogen-oxygen compounds which are the building blocks of explosives such as TNT, plastiques, and nitroglycerine. The device could be used to scan persons entering airport terminals, nuclear power plants, defense installations, or other sensitive locations, providing greater security against potential terrorism. This device works on a glow discharge principle, and is more specifically called an ''Atmospheric Sampling Glow Discharge Ionization'' (ASGDI) source. The new detector is a highly automated, miniaturized version of research mass spectrometers widely used to trace constituents of chemical mixtures. Detail of this device's construction and ...
After the LEP dismantling Phase the Cooling and Ventilation Group has started the LHC construction work. Year 2001 through to 2004 will certainly be the most important period of activity for the CV group in the erection phase The author will report on the current works that are in progress on the different LHC Points distinguishing between the Ventilation and the Water Cooling installations. The Ventilation work completed in the new surface buildings in Points 1, 4,5,6 and 8. The work for the Cooling plants comprehend to the pumping stations, the cooling towers and the chilled water production stations in Points 1 and 5, For all of these activities, an updated report of the progress the work, the planning and of the expenses are given. Finally, a brief overview of the future activities is presented.
The Hawaii Demand-Side Management Resource Assessment was the fourth of seven projects in the Hawaii Energy Strategy (HES) program. HES was designed by the Department of Business, Economic Development, and Tourism (DBEDT) to produce an integrated energy strategy for the State of Hawaii. The purpose of Project 4 was to develop a comprehensive assessment of Hawaii`s demand-side management (DSM) resources. To meet this objective, the project was divided into two phases. The first phase included development of a DSM technology database and the identification of Hawaii commercial building characteristics through on-site audits. These Phase 1 products were then used in Phase 2 to identify expected energy impacts from DSM measures in typical residential and commercial buildings in Hawaii. The building energy simulation model DOE-2.1E was utilized to identify the DSM energy impacts. More detailed information on the typical ...
The data center in this study had a total floor area of 8,580 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 440 racks, and was located in a 208,240 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but served by the main building chiller plant and make-up air system. Additionally, it was served by a single electrical supply with no provision for backup power. The data center operated on a 24 hour per day, year-round cycle, and users had all hour full access to the data center facility. The study found that data center computer load accounted for 23% of the overall building electrical load, while the total power consumption attributable to the data center including allocated cooling load and ...
Long term indoor radon gas measurements using a passive monitor are now being conducted in the basement HVAC machine rooms of about fifty commercial buildings, which are built in the Tokyo and Nagoya metropolitan area. Ventilation rates are also measured during the monitoring period. The earliest results show that the highest concentration was about twice of the EPA Standards and was obtained at Nagoya in autumn and no clear seasonal change was seen in radon concentration so far, and that the correlation between radon concentration and inverse number of ventilation rate was positive but not high. (orig.). (2 refs., 4 figs., 2 tabs.).
The Nuclear Safety Commission acknowledged the policy of the Agency of Natural Resources and Energy to cope with these important matters on August 8, 1984. The main contents of the investigation and deliberation were as follows, As to the prevention of the occurrence of fires, the prevention of the leak and spread of inflammable liquid and gas, the installation of protective relays and so on, the use of incombustible materials and aseismatic design and the installation of lightning arresters. As to the detection of fires and fire fighting, the proper selection and arrangement of fire detectors and extinguishers, the extinguishers which do not harm the safety function of structures and equipment, and the extinguishers which are not affected by natural phenomena. As to the reduction of the effect of fires, the proper installation of fire walls and extinguishers, and the high temperature shut off of ...
Slowly, scientists come to realize that there are huge quantities of natural methan hydrates and their interest is awakened. Important questions in this connection are their possible use as future energy sources, the consequences of using methan hydrates on the climate, their integration into the carbon cycle, the cementation of the continental slopes by gas hydrates and their stability and their role in some geological-biological-geochemical processes, especially in the marine area. Towards the end of the 20th century, the basic problems and applied problem scenarios, e.g. the foundation of production platforms dor petroleum and natural gas in gas-hydrate-containing sediments, was the reason for Japan, Canada, USA, China, Germany and India to install national research programmes of various sorts in order to deal with the problems of gas hydrates. Also international programmes like ...
The outlook for natural gas (from both supply and price perspectives) has improved dramatically since the late 1970s, and significant advances have been made in electrical generation technologies which use gas. For example, gas-fired combined-cycle turbine units have become even more efficient and reliable. These units can be installed quickly (12 to 24 months versus 8 to 15 years for coal and nuclear units), and they may be brought on-line in small incremental blocks. This modular construction feature offers greater flexibility to utility planners, and the relatively low capital cost of combined-cycle units reduces financial uncertainties. The purpose of this chapter is to compare two electric power generating options, a new coal-fired powerplant and a new natural gas fired combined-cycle unit, from both economic and environmental perspectives. The comparison is based on a 240 ...
During the operation of the Fast Flux Test Facility (FFTF), radioactive gases, primarily xenon and krypton, will be produced which will require processing and storing. Two systems have been installed in the FFTF for handling these gases: (1) one to handle, primarily, the reactor cover gas system, and (2) a second to handle the cells and cover gas systems, other than the reactor, whose atmosphere may become contaminated. The system that processes the reactor cover gas, which is argon, is called the Radioactive Argon Processing System (RAPS). The effluent argon from RAPS will normally be sufficiently decontaminated to allow its reuse as the reactor cover gas. If the radioactive level in the RAPS becomes too high, the exhaust stream will be diverted to the Cell Atmosphere Processing System (CAPS), a system which can function as a backup to RAPS. The design and operation of the RAPS and ...
At the Tokai Research Establishment of Japan Atomic Energy Research Institute, the radioactive solid waste incineration unit with a capacity of 100 kg/h was installed in 1979, since then the unit has been routinly operated. An off-gas cleaning system of the unit consists mainly of a primary and secondary ceramic filters, a heat resistant HEPA filter and a scrubber. A series of hot test was carried out to examine the docontamination performance for radionuclides in the off-gas cleaning system. In the test, simulated wastes contaminated with a known quantity of radionuclides were burned in the unit, and radioactive concentrations in the off-gas were measured. And then, the following data were obtained: a retention factor of radionuclides in a furnace and a decontamination factor for radionuclides in each of off-gas cleaning components. And also overall decontamination factors, defined ...
Modern combined cycle power plants with natural gas as the only fuel reach efficiencies of up to 58% for electric power generation. Nevertheless the reserves of natural gas are more limited compared to the reserves of coal. Therefore possibilities should be investigated to use coal for such plants also. One concept, that combines the use of coal in a combined cycle application with high efficiencies is examined in this paper. According to this concept the exhaust gas of the gas turbine (vitiated air) is the combustion air for the pulverised coal combustion, that takes place in the bottoming steam generator. Due to the low oxygen content of the vitiated air the burnout of the coal may be incomplete. In order to avoid the incomplete combustion of the coal and the resulting decrease of the efficiency of the plant and possible emission problems, a catalyst, that converts carbon monoxide and unburnt carbon ...
This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per kilowatt, which run a few hours a day on gas or ...
This paper reports on pumped storage plants which have become an effective way for some utility companies that derive power from hydroelectric facilities to economically store baseload energy during off-peak hours for use during peak hourly demands. According to the Electric Power Research Institute (EPRI) in Palo Alto, Calif., 36 of these plants provide approximately 20 gigawatts, or about 3 percent of U.S. generating capacity. During peak-demand periods, utilities are often stretched beyond their capacity to provide power and must therefore purchase it from neighboring utilities. Building new baseload power plants, typically nuclear or coal-fired facilities that run 24 hours per day seven days a week, is expensive, about $1500 per kilowatt, according to Robert Schainker, program manager for energy storage at the EPRI. Schainker the that building peaking plants at $400 per kilowatt, which run a few hours a day on gas or ...
Soil gas, soil, and water were assessed for organic and inorganic constituents at the former 19th Street landfill at Fort Gordon, Georgia, from February to September 2010. Passive soil-gas samplers were analyzed to evaluate organic constituents in the hyporheic zone and flood plain of a creek and soil gas within the estimated boundaries of the former landfill. Soil and water samples were analyzed to evaluate inorganic constituents in soil samples, and organic and inorganic constituents in the surface water of a creek adjacent to the landfill, respectively. This assessment was conducted to provide environmental constituent data to Fort Gordon pursuant to requirements of the Resource Conservation and Recovery Act Part B Hazardous Waste Permit process. The passive soil-gas samplers deployed in the water-saturated hyporheic zone and flood plain of the creek adjacent to the former landfill indicated the ...
This report describes selective catalytic reduction (SCR) technologies which offer an economical and effective means of reducing nitrogen oxide emissions from electricity generation facilities and reviews the feasibility and cost effectiveness of employing this technology on electricity generating facilities in Ontario. Based on experiences in the United States, in British Columbia, and internationally in Japan and Germany, the indication is that the technology for the installation of SCR systems on new gas-fired combined cycle power plants and existing coal-fired power plants has grown enormously during the past decade, and has been established as the control technology of choice for nitrogen oxide emissions. It is widely acknowledged to reduce power plant nitrogen oxide emissions, and do so at a very reasonable incremental cost. It is estimated that the annualized cost of installing and operating a SCR at a large ...
The Fast Flux Test Facility (FFTF) is a 400-MWt, sodium-cooled reactor located on the Hanford Site near Richland, Washington, USA. The FFTF is owned by the U.S. Department of Energy and is operated by the Westinghouse Hanford Company. The FFTF was designed to test fuels and materials for use in liquid metal reactors. Since initial operation in 1982, anticipated breaches of experimental fuel pins have released fission products, including cesium, into the primary sodium. Because of its high volatility, cesium vaporizes into the cover gas space, where it condenses on components and equipment and is transported into the cover gas outlet. Because of the long half-life of "1"3"7Cs, these deposits result in long-term, local radiation levels that make contact maintenance difficult. Thus, a cesium trap was installed in FFTF to reduce the cesium level in the sodium. The trap could also permit a Run Beyond Cladding Breach (RBCB) ...
Hazardous UV-radiation and short-wavelength visible (blue) light is emitted by the high temperature plasma above the welding-keyhole. Ozone and NO_x is produced due to UV-induced photodissociation of oxygen and high temperature gas-phase reactions. Spectral measurements of the plasma emission show that the allowed dose for UV-radiation and blue light exposure per work day can be exceeded in as short as a few seconds. Similarly, measurements and models of the ozone and NO_x concentration show that the maximum workplace concentrations might be reached quickly if no appropriate exhaust and filter system is installed. (author)
This is the first report about a relevant and compiled information on the Mexican Energy Sector. It was realized in one volume by the University Energy Program of the National Autonomous University of Mexico and it comprises information for the period 1996-1997. In the chapter 1 there are presented the numbers of hydrocarbon reserves. Chapter 2 treats about production, events and its results. Likewise chapter 3 shows information about the typical Installations for petroleum, gas and electricity including through of the nuclear energy. In the chapter 4, named Energy Consumption, is presented a National energy balance for 1996 and, finally there are a sections about the prices, the rates and a glossary to facilitate its understanding. (Author)
The development of the Aasgard field complex off mid Norway represents one of the largest technical and economic challenges yet faced by the Norwegian offshore industry. The article deals briefly with this development. The project comprises a floating production, storage and offloading (FPSO) vessel for the oil production, and a large semisubmersible for the gas phase. More than 60 subsea completed wells for production and injection on 15 seabed templates are planned, with some 300 km of seabed pipelines also to be installed on the field which will produce for 30 years. The total investment will be NOK 31 billion. 1 fig.
The data center in this study had a total floor area of 3,024 square feet (ft{sup 2}) with one-foot raised-floors. It was a rack lab with 147 racks, and was located in a 96,000 ft{sup 2} multi-story office building in San Jose, California. Since the data center was used only for testing equipment, it was not configured as a critical facility in terms of electrical and cooling supply. It did not have a dedicated chiller system but was served by the main building chiller plant and make-up air system. Additionally it was served by only a single electrical supply with no provision for backup power in the event of a power outage. The Data Center operated on a 24 hour per day, year-round cycle, and users had full-hour access to the data center facility. The study found that data center computer load accounted for 15% of the overall building electrical load, while the total power consumption attributable to the data center ...
An emergency shutdown system for high-temperature gas-cooled pebble-bed reactors is proposed in addition to the common absorber rod shutdown system. This system is based on the strongly absorbing effect of small boronated graphite spheres (called KLAK), which trickle in case of emergency by gravity from the top reflector into the reactor core. The inner reflector of the Siemens-Argonaut reactor was substituted by an assembly of spherical Arbeitsgemeinschaft Versuchsreaktor fuel elements, and the shutdown effect was examined by installing well-defined KLAK nests inside this assembly. The purpose was to develop and prove a calculational procedure for determining criticality values for assemblies of large fuel spheres and small absorbing spheres.
Fires and explosions have been identified as major potential hazards for Oil and Gas Floating Production Storage Offloading (FPSO) installations and pose risk to personnel, assets, and the environment. Current fire and explosion assessment (FEA) tools require physical effect modeling software and follows standards from API, ISO, and engineering practices. However, the tools are not specific to any particular system such as an FPSO, and do not provide comprehensive guidance for safety engineers to perform FEA. This paper discusses the development of a screening and comparison tool for FEA on FPSOs and the incorporation of an expert system into the tool. The results are computerized using MS Excel/VBA to provide a structured and comprehensive assessment on each equipment and module handling ...
The report gives background design data for a specific copper smelter. The data is sufficiently detailed to allow air pollution control system engineering studies to be conducted. These studies will be concerned primarily with lean SO/sub 2/ streams that currently are not being captured. Physical layout of the smelter and the surrounding area is presented, along with existing control equipment. Ductwork that would be considered for future system tie-in is defined. Emissions from operating equipment, gas flow rates, temperatures, sulfur balance, and a process flow sheet are included. Utilities, stack dimensions, footing requirements, and solid waste handling are defined. Available area for new control equipment, gas characteristic variation, and potential new control equipment installation problems are discussed. Portions of this document are not fully legible. (GRA)
The report gives background design data for a specific copper smelter. The data is sufficiently detailed to allow air pollution control system engineering studies to be conducted. These studies will be concerned primarily with lean SO/sub 2/ streams that currently are not being captured. Physical layout of the smelter and the surrounding area is presented, along with existing control equipment. Ductwork that would be considered for future system tie-in is defined. Emissions from operating equipment, gas flow rates, temperatures, sulfur balance, and a process flow sheet are included. Utilities, stack dimensions, footing requirements, and solid waste handling are defined. Available area for new control equipment, gas characteristic variation, and potential new control equipment installation problems are discussed. (GRA)
An incinerator for the treatment of low-level radioactive solid wastes was installed in Tokai Research Establishment, JAERI, 1966. The incinerator was equipped with a scrubber, cyclone, electrostatic precipitator and HEPA filter. The retention factor (R.F.) of the furnace as well as the decontamination factors (D.F.) of each dust collector were measured using "3"2P as a tracer under various conditions. It was found that the overall D.F. of the incinerator was improved by the increase of the temperature in the furnace, decrease of the off gas flowrate, increase of the charged voltage of the electrostatic precipitator and by the increase of the liquid gas ratio of the scrubber. The overall D.F. of the incinerator (including the R.F. in the furnace) on the standard operating conditions was 9.1x10"6. (auth.).
This final report for the Swiss Federal Office of Energy (SFOE) reports on work done in the area of gasification of biomass. The use of dung, manure and sewage sludge as sources of energy is described and discussed. Hydrothermal gasification is proposed as an alternative to conventional gas-phase processes. The aim of the project in this respect is discussed. Here, a catalytic process that demonstrates the gasification of wet biomass to synthetic natural gas (SNG) in a continuously operating plant on a laboratory scale is being looked at. Difficulties encountered in preliminary tests are discussed. Long-term catalyst stability and the installations for the demonstration of the process are discussed, and gasification tests with ethanol are commented on.
After a long period of stagnation in the UK, Europe and the USA, there is now a real expectation that new nuclear plants will be under construction shortly. Several factors have contributed to this change of position in the UK: the growing realisation that effective action is needed to offset greenhouse gas emissions; higher prices for fossil fuels; increasing reliance on overseas supplies of oil and gas; the limitations of wind and wave power and distribution; security of supply; the gradual realisation in the deregulated electricity generation market that nuclear power is competitive and the pending closure of most of the UK's nuclear fleet within less than 15 years. All these factors have led to a reversal of the UK Government's attitude to nuclear power, which has now ruled in favour of allowing a new generation of nuclear plants being built. This paper summarises some of the arguments that have led to this decision and the ramifications of ...
Deregulation and restructuring changes in the electric power industry have provided opportunities to build new power plants. These power plants, however, will not enjoy long-term power purchase agreements with the utilities they serve, but will have to respond to the market. This is where the term `merchant plant` originates. Calpine Corp. presented its reasons for believing that now is the best time to be building new merchant plants based on modern natural gas-fired, combined-cycle power plants. Among those reasons are: (1) construction of new nuclear power plants has been rejected by people on both sides of the border, (2) attempts to promote alternative energy sources such as solar, wind and biomass have not added significant generation capacity and are not likely to do so in the near future because of their high cost, and (3) coal-fired plants are also facing environmental challenges. For all these reasons, modern ...
Economics may one day dictate that it makes sense to replace oil or natural gas with coal in boilers that were originally designed to burn oil or gas. In recognition of this future possibility, Pittsburgh Energy Technical Center (PETC) has supported a program led by ABB Power Plant Laboratories in cooperation with the Energy and Fuels Research Center of Penn State University to develop the High Efficiency Advanced Coal Combustor (HEACC). The objective of the program is to demonstrate the technical and economic feasibility of retrofitting a gas/oil designed boiler to burn micronized coal. In support of the overall objective the following specific areas were targeted: a coal handling/preparation system that can meet the technical requirements for retrofitting microfine coal on a boiler designed for burning oil or natural gas; maintaining boiler thermal performance in accordance with specifications when ...
Describes the wastes produced and the waste disposal methods used at BEWAG power plants. Wastes covered include fly ash, fluidized bed ash, gypsum from flue gas desulfurization and evaporation residues. Disposal methods include using ashes and gypsum to make building materials. Despite many years of experience in the utilization and disposal of residues from coal-fired power stations BEWAG have not encountered any disposal problems. 5 tabs.
This is a report on modification of a locomotive diesel engine to a dual-fuel engine to determine if the dual fuel engine in railway service will provide high performance, lower fuel and maintenance costs. After the locomotive was modified and the new governor and linkage were installed by General Motors at the BN's Northtown Diesel Shop near Minneapolis, the locomotive went through startup procedures. General Motors participated in startup. Some calibration, adjustments and minor piping changes were required but in general the problems encountered in startups were quite insignificant. The locomotive was connected to the load box (static test) during startup and at 720 RPM exceeded the required output for this test as established by the parties. Operation on straight oil over the range from idle through No. 8 throttle notch and on dual fuel from No. 5 through No. 8 throttle notch was smooth as was the transfer from oil to gas and from ...
Work on this coke oven gas cleaning demonstration project (CCT-II) this quarter has been focused on Phase IIB tasks, and include engineering, procurement, construction, and training. Additionally, plans for changes in the operating schedule of the coke plant that affect the demonstration project are described. Engineering efforts are nearly complete. Remaining to be finalized is an assessment of electrical heat tracing/insulation needs for pipe lines, assessment of fire protection requirements, and instrument modifications. Procurement of all major equipment items is complete, except for possible additions to fire fighting capabilities. Major focus is on expediting pipe and structural steel to the project site. Civil construction is complete except for minor pads and bases as required for pipe supports, etc. Erection of the hydrogen sulfide and ammonia scrubber vessels is complete. Installation of scrubber vessel internals is underway. A ...
As part of three ongoing research projects, the Gas Research Institute (GRI) is studying the natural gas industry's impacts on wetlands and how to manage operations so that impacts can be minimized or eliminated. The objective of the first project is to gain a better understanding of the causes and processes of wetland loss in the Louisiana deltaic plain and what role gas pipeline canals play in wetland loss. On the basis of information gathered from the first projects, management and mitigation implications for pipeline construction and maintenance will be evaluated. The objective of the second project is to assess the floral and faunal communities on existing rights-of-way (ROWs) that pass through numerous types of wetlands across the United States. The emphasis of the project is on pipelines that were installed within the past five years. The objective of the third project is to evaluate the ...
One way to intensify heat and mass transfer processes in column-type equipment is through use of contact devices with directional gas phase injection into a liquid. Making the perforations at an angle to the tray plane permits a rise in the permissible gas velocity in the column, since inertial force adds to gravity during separation. Different arrangements of the jet-forming elements relative to one another and to partitions and baffle-type contacts installed on the trays can improve phase contact conditions and intensify heat and mass transfer. Design of jet-type trays for a specific purpose requires that the influence of jet-forming, element design parameters on at least the fluid dynamic situation on the tray be known. In this work, the authors evaluate the influence of tab bend-up angle on jet tray working characteristics. These investigations demonstrate that the jet inclination angle (the angle of maximum ...
Modern combined cycle power plants with natural gas as the only fuel reach efficiencies of up to 55% for electric power generation. Nevertheless the reserve of natural gas is more limited compared to the reserve of coal. Therefore possibilities should be investigated to use coal for such plants also. One concept, that combines the use of coal in a combined cycle application with high efficiencies is examined in this paper. According to this concept the exhaust gas of the gas turbine (vitiated air) is the combustion air for the pulverized coal combustion, that takes place in the bottoming steam generator. Due to the low oxygen content of the vitiated air the burnout of the coal may be incomplete. In order to avoid the incomplete combustion of the coal and the resulting decrease of the efficiency of the plant and possible emission problems, a catalyst, that converts carbon monoxide and unburnt carbon to ...
The TRIGA-SPEC experiment has been installed recently at the research reactor TRIGA Mainz. Ground state properties like masses, charge radii, spins, and moments of short-lived nuclides can be determined with very-high precision using the Penning trap mass spectrometer TRIGA-TRAP, and the collinear laser spectroscopy setup TRIGA-LASER. Short-lived neutron-rich radionuclides in the mass range 80 < A < 140 are produced by thermal neutron induced fission of e.g. U-235, Pu-239 or Cf-249, respectively. For the extraction and ionization of the fission products a gas-jet system is coupled to a 2.45-GHz ECR ion source for the production of singly charged ions. The gas-jet has been tested on-line and fission products have been extracted. First off-line tests of the ion source have been performed successfully with argon gas. The results of the commissioning test of the ion source and the on-line coupling of ...
This final report for the Swiss Federal Office of Energy (SFOE) presents the results of a project that involves the building of a joint biogas plant serving 60 farmers and industrial companies with an annual processing capacity of 45,000 tons. The plant is to produce biogas to be fed into the gas mains and will not only reduce nutrient loading in a region with an extensive livestock industry but also reduce carbon dioxide emissions by using the gas as a motor fuel. The importance of the project with respect to both the environment and energy policy-making is discussed and the costs involved are examined. Details are presented on the technology used and on the material flows involved. Figures are quoted on energy production. The various biogenic substrates used, such as food wastes, waste oils, cereal wastes and used mushroom substrates, are discussed, as is the use of the solid and liquid outputs of the digester in farming ...
Natural fractures and in situ stresses commonly dictate subsurface reservoir permeability and permeability anisotropy, as well as the effectiveness of stimulation techniques in low-permeability, natural gas reservoirs. This paper offers an initial prediction for the orientations of the fracture and stress systems in the tight gas reservoirs of the Frontier Formation, in the Green River basin of southwestern Wyoming. It builds on a previous report that addressed fractures and stresses in the western part of the basin and on ideas developed for the rest of the basin, using the principle that thrust faults are capable of affecting the stress magnitudes and orientations in little-deformed strata several hundreds of kilometers in front of a thrust. The prediction of subsurface stresses and natural fracture orientations is an undertaking that requires the willingness to revise models as definitive data are acquired during ...
In the green building of Shanghai Research Institute of Building Science, the evacuated tubular solar collectors with a total area of 150 m{sup 2} were installed to provide heating for the covered area of 460 m{sup 2}. The floor heating coil pipes were made of high-quality pure copper with the dimension of {phi} 12 x 0.7 mm. Under typical weather condition of Shanghai, the average heating capacity was 25.04 kW during the working hours from 9:00 to 17:00, which was sufficient to keep indoor thermal environment. The average electric COP of the floor heating system was 19.76 during the system operation. Compared with the widely used air-source heat pump heating systems with the electric COP of 3.5 in Shanghai, the solar-powered floor heating system shows great potential in energy conservation in winter. With respect to the whole heating period, the solar fraction was 56%. According to the performance analysis of the system ...
The increasing diffusion of small-scale energy systems within the distributed generation (DG) paradigm is raising the need for studying the environmental impact due to the different DG solutions in order to assess their sustainability. Addressing the environmental impact calls for building specific models for studying both local and global emissions. In this framework, the adoption of natural gas-fueled DG cogeneration technologies may provide, as a consequence of cogeneration enhanced overall energy efficiency and of natural gas relatively low carbon content, a significant reduction of global impact in terms of CO2 emissions with respect to the separate production of electricity and heat. However, a comprehensive evaluation of the DG alternatives should take into account as well the impact due to the presence of plants spread over the territory that could increase the local pollution, in particular due to CO and NOx, and ...
It is an object of the present invention to provide an improved installation having a pressurized fluid circuit incorporating fluidic brakes for restricting fluid flow through a breach of the installation. (author).
This paper describes a gas transmission pipeline company with dissimilar local control and Supervisory Control and Data Acquisition (SCADA) systems that had formed over time, and the solution that was put into place to consolidate those systems. Great Lakes Gas Transmission Company (GLGT) had historically operated the pipeline from four geographically different locations with a combination of various local man-machine interface (MMI) control systems and an aging SCADA system. As new control systems were installed at compressor and meter stations, local and corporate data acquisition needs changed. It became apparent that the existing SCADA system which telemetered a minimal set of control data could no longer support growth requirements. The decision was made to replace the old SCADA system with a new open state-of-the-art architecture. As a result of competitive bidding, the Valmet OASyS (Open Architecture SyStem) was ...
The purpose of the project is to further develop a Danish natural gas reformer system including optimisation of subsystems and the overall system consisting of a natural gas reformer and fuel cell CHP generator. This will contribute to the evaluation of to what extend Denmark shall develop small reformer units for PEM fuel Cells. In the project a reformer system with a high degree of automatic control has been build that fulfils the CHP requirements to operation time, dynamics etc. This work, with a FP05 reformer unit, has given valuable results concerning the possibilities and limitations of the reformer technology for CHP usage. It is important that the reformer and fuel cell units are designed with matching yields to optimise efficiency, turn-down start-up time etc. The burner that delivers heat for the steam reaction shall be able to use natural gas as fuel. This gives the possibility of using ...
A hydrogen peroxide injection system was designed and installed in the stack of a 5,274 million J/hr industrial pilot plant scale combustion chamber using natural gas as fuel. The concentration of peroxide in the gas stream was precisely controlled by continuous injection using an electromagnetic dosage pump, the liquid 50% peroxide solution was finely dispersed into the gases by a water cooled custom designed delivery system with a spray nozzle at the tip. Residence times between 0.1 and 1.8 seconds and concentrations of H{sub 2}O{sub 2} between 280 ppm and 4,000 ppm were used during the test runs. CEMS for total hydrocarbons, carbon monoxide, nitrogen oxides, as well as an ultrasonic gas flow monitor were used to measure the effect of hydrogen peroxide in reducing the emissions of these pollutants. Destruction removal efficiencies between 25% and 100% were observed for hydrocarbons, and concentrations ...
After a lot of efforts to develop a spark-ignition type dual-fuel engine which can separately use both gas and liquid fuels, a dual-fuel engine which uses ethanol as a liquid fuel has been developed. In this paper, a 13A/LPG dual-fuel engine which uses LPG as an emergency fuel is also introduced. During the development of a dual-fuel engine using city gas (13A)/liquid fuel such 4 kinds of liquid fuel as kerosene, gasoline, ethanol and isobutanol have been examined. As a result of testing, it was proved that ethanol is preferable and a 13A/ethanol DF engine can be used as a generator of different outputs, 100KW for normal service and 70KW for emergency service, without any problems in practical use. On the other hand, a city gas (13A)/LPG dual-fuel engine requires the modification of the fuel feed system and the installation of a ignition device which can change the ignition timing by means of the fuel ...
Calls for containers to transport compressed natural gas, and a ship or barge to house some 200 employees in the Terra Nova offshore oilfield while the oil field's floating production, storage and offloading (FPSO) system is undergoing a major overhaul, are attracting attention on Canada's east coast offshore oilpatch. The FPSO is located offshore, 350 km east of St. John's, Newfoundland. Petro-Canada, operators of the FPSO anticipate that by having all required personnel nearby, the total shutdown time for the overhaul could be minimized. The CNG container was designed by Trans Ocean Gas Inc. in response to an invitation by Husky Oil and Petro-Canada, the White Rose field partners. Trans Ocean Gas strongly believes that CNG will become the technology of choice for getting natural gas ashore and to markets from stranded hydrocarbon pools in Atlantic Canada and the rest of the ...
... 2010-10-01 2010-10-01 false Battery installations. 120.354 Section 120...Sources and Distribution Systems § 120.354 Battery installations. (a) Large batteries. Each large battery installation...
Ways of reducing the excessive energy consumption in the Polish sugar industry are examined. The three main areas where energy reduction measures might be taken are: reducing the process heat demand which arises from the need to evaporate excess water from the juice supplied to the crystallisers; improving the effectiveness of the thermal system by moving from the present four-effect evaporation to five-effect evaporation and using crystallisation vapours for juice heating; replacing old steam boilers with more efficient units. Most Polish sugar factories are relatively small, however, and the energy saving measures, all of which require the installation of more modern equipment, are not economically feasible in the short term. Moreover, the stringent limits on atmospheric emissions which come into effect in 1998 will require factories to use low-sulphur coal and install costly glue-gas cleaning equipment. With limited ...
The build-up of frost on unit cooler surfaces, if not periodically cleared, will eventually cause impairment of the unit's performance, eventually rendering it useless. Thus it is necessary, in spaces below freezing, to provide an external supply of heat to warm the unit sufficiently to melt the frost and remove it. In large central-plant-type systems the most common method employed for supplying heat is from the high-pressure side of the refrigeration system, referred to as hot gas defrost. Although the heat thus captured for use in melting frost would otherwise be rejected external to the system, the defrosting process is not free of cost. There are significant losses associated with the process the magnitude of which have not heretofore been fully identified. This paper looks at the heat and mass transfer and fluid flow mechanisms involved in the hot gas defrost process in large commercial freezers. It suggests ...
Work of the Geothermal Heat Pump Consortium (GHPC), a joint program of the US Department of Energy, the US Environmental Protection Agency, the US electric utilities and industry was described. The consortium was established to improve energy efficiency and reduce CO{sub 2} emissions by moving ground source and groundwater source heat pumps from niche products to ten percent of the new and retrofit HVAC market in less than a decade. The GHPC program focuses on : (1) reducing first costs through technology innovation and innovative financing, (2) strengthening the infrastructure though education, training and work codes and regulations, and (3) building confidence in the technology through demonstrations of cost-effectiveness, low maintenance efforts and through marketing programs. Results of the first two years of operations were described. Results indicate that the objectives are being achieved, the number of installations is increasing and a ...
Three aspects of the research project ``Surface physics with cold and ultracold neutron reflectometry`` were stressed during the present first year: (1) Setup of the reflectometer facility at the research reactor of the Rhode Island Nuclear Science Center. The installation provides a narrow ``pencil beam`` analyzed by time of flight using a chopper system. Following beam characterization and a test measurement of the total cross section of copper single crystal first reflectivity measurements are currently performed using a supermirror. (2) Design stud for the ultracold neutron imaging system, with involvement of the relevant industry. Bids are available for several components indicating that it will be very difficult to build the entire system unless further funds become available. (3) Analysis of features of neutron reflection from surfaces with special emphasis on the effect of surface roughness both on the specular beam and the diffusely ...
Three aspects of the research project Surface physics with cold and ultracold neutron reflectometry'' were stressed during the present first year: (1) Setup of the reflectometer facility at the research reactor of the Rhode Island Nuclear Science Center. The installation provides a narrow pencil beam'' analyzed by time of flight using a chopper system. Following beam characterization and a test measurement of the total cross section of copper single crystal first reflectivity measurements are currently performed using a supermirror. (2) Design stud for the ultracold neutron imaging system, with involvement of the relevant industry. Bids are available for several components indicating that it will be very difficult to build the entire system unless further funds become available. (3) Analysis of features of neutron reflection from surfaces with special emphasis on the effect of surface roughness both on the ...
The Baird and McGuire site is a former chemical manufacturing facility in northwest Holbrook, Massachusetts, approximately 14 miles south of Boston. From 1912 to 1983 the company operated a chemical manufacturing and batching facility on the property. Manufactured products included herbicides, pesticides, disinfectants, soaps, floor waxes and solvents. Waste disposal methods at the site included direct discharge into the soil, nearby brook and wetlands, and a former gravel pit (now covered) in the eastern portion of the site. EPA conducted a removal action at the site in 1983 after a waste lagoon overflowed spreading contaminants into the Cochato River. The company ceased operating shortly thereafter. A second removal action was conducted in 1985, following the discovery of dioxin in site soils. EPA also conducted an Initial Remedial Measure at the site from 1985 through 1987 which involved constructing a new water main to direct water away from the site, removing ...
H Power Enterprises of Canada was founded in 1997; currently, it has 40 employees and expect to grow to about 50 by mid-2000. The company is engaged in fuel cell technology development , manufacturing and marketing. The company has the advantage that its technology has been proven, products are already commercialized, and strategic alliances are already in place to make an assault on the market. The concept of proton exchange membrane fuel cell technology is explained in terms of efficiency, response time, power density, stack manufacturing cost, maintenance cost, stack life and compatible thermal loads. Individual products, their energy and operating efficiency, potential applications and potential markets are reviewed. It is estimated that for stationary fuel cells the market will be worth $ 30 billion by 2030. In the United States alone, remote residential cogeneration sites are estimated at 500,000. The estimates for uses in transportation is estimated at $ 1 billion/year by 2002 ...
This is the final report of a two-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). This project has examined the fundamental chemistry of plutonium that affects the integration of hydrothermal technology into nuclear materials processing operations. Chemical reactions in high temperature water allow new avenues for waste treatment and radionuclide separation.Successful implementation of hydrothermal technology offers the potential to effective treat many types of radioactive waste, reduce the storage hazards and disposal costs, and minimize the generation of secondary waste streams. The focus has been on the chemistry of plutonium(VI) in solution with carbonate since these are expected to be important species in the effluent from hydrothermal oxidation of Pu-containing organic wastes. The authors investigated the structure, solubility, and stability of the key plutonium complexes. Installation and ...
Industrial facilities offer a wide variety of design challenges to engineers, including the mechanical engineers who design the HVAC, the process, exhaust, and other required mechanical systems; the mechanical contractors who install and maintain the systems (and who also may do design work); and the owners` engineers who are responsible for the day-to-day operation of their facilities. Along with the responsibility to see that all systems function as intended is the responsibility to ensure that all worker health concerns are addressed. These include heat stress avoidance and the proper control of harmful substances. The services of industrial hygienists may be required to ensure this. These may be independent consultants or the staff members of mechanical design firms. In addition, it is not unusual for major corporations that own manufacturing plants to have staff industrial hygienists. The accompanying sidebar presents a checklist of items to be considered when ...
A solar-driven 10-ton LiBr/H2O single-effect absorption cooling system has been designed and installed at the School of Renewable Energy Technology (SERT), Phitsanulok, Thailand. Construction took place in 2005, after which this system became fully operational and has been supplying cooling for our main testing buildings air-conditioning. Data on the systems operation were collected during 2006 and analyzed to find the extent to which solar energy replaced conventional energy sources. Here, we present these data and show that the 72m2 evacuated tube solar collector delivered a yearly average solar fraction of 81%, while the remaining 19% of thermal energy required by the chiller was supplied by a LPG-fired backup heating unit. We also show that the economics of this cooling system are domi...
Ground-source heat pump systems (GSHPSs), also referred to as geothermal heat pump systems (GHPSs), have been widely used in residential and commercial buildings for years due to their outstanding energy utilization efficiencies. In this study, an energy and exergy modeling of solar assisted ground-source heat pump systems for residential applications is presented for system analysis and performance evaluation. In this regard, the performance of a solar assisted ground-source heat pump heating system, installed in Solar Energy Institute of Ege University, Izmir, Turkey, is evaluated based on the actual operational data to show how energy and exergy efficiencies values change with the system. The average heating coefficient of performances (as energy efficiencies) of the solar assisted ground-source heat pump (GSHP) unit and the overall system are obtained to be 2.64 and 2.38, respectively. The average exergy efficiency of the system is ...
The paper describes the work underway to adapt a former US Navy diesel electric drive ship as a 2.4 Megawatt fuel cell powered, US Coast Guard operated, demonstrator. The Project will design the new configuration, and then remove the four 600 kW diesel electric generators and auxiliaries. It will design, build and install fourteen or more nominal 180 kW diesel fueled molten carbonate internal reforming direct fuel cells (DFCs). The USCG cutter VINDICATOR has been chosen. The adaptation will be carried out at the USCG shipyard at Curtis Bay, MD. A multi-agency (state and federal) cooperative project is now underway. The USCG prime contractor, AEL, is performing the work under a Phase III Small Business Innovation Research (SBIR) award. This follows their successful completion of Phases I and II under contract to the US Naval Sea Systems (NAVSEA) from 1989 through 1993 which successfully demonstrated the feasibility of diesel fueled DFCs. The ...
In order to effectively recover uranium, rotation speed of solid cathode was examined, and effect of uranium concentration and current density on electrodeposition were confirmed. And the potentiostatic and galvanostatic electrorefining experiments were conducted. Element used in the experiments were Zr, Nd, La chlorides. The reduction potentials of chlorides metals on liquid Cd cathode were measured by cyclic voltammetry experiments. The electrowinning experiments were performed in order to recover small amounts of uranium in salt. Experimental set-up for the batch type reductive extraction experiments were developed and installed. On the base of experimental results of batch type, multi-stage extraction equipment was set-up, and optimum number of stage and recover yield were measured. In the oxidative extraction study is examine selective separation behavior of the rare earth metals from alloy composed of actinide and lanthanide metals to determine the effective ...
The CleverFarm project started out to build an integrated monitoring system for wind farms, where all information would be available and could be used across the wind farm for maintenance and component health assessments. This would enable wind farm operators to prioritise their efforts, since they have a good view of the farm status from home. A large emphasis was placed on the integration of condition monitoring approaches in the central system, enabling estimates of the remaining lifetime of components, especially in the nacelle. During the 3,5 years of the project, software and hardware was developed and installed in two wind farms in Denmark and Germany. The connected hardware included two different condition monitoring systems based on vibration sensors from Gram&Juhl and ISET, plus a camera system developed by Overspeed. Additionally, short-term predictions of the wind farm output were delivered by DMI and Risoes Prediktor system ...
Modernisation of older office buildings commonly includes installation of air conditioning systems as good air quality and thermal comfort will improve the staff`s efficiency at work. However, what about tenants who want their own, individually controlled single-storey air conditioning plang? And what about retrofitting further storeys with single-storey air conditioning? An exemplary solution to this problem was found in Hamburg. (orig.) [Deutsch] Bei der Sanierung aelterer Buero- und Geschaeftshaeuser werden die Raeume immer haeufiger mit Klimaanlagen ausgestattet. Ein Grund fuer den Trend zur Klimatisierung: Gute Luftqualitaet und angenehme Temperaturen erhoehen die Leistungsfaehigkeit des Menschen. Was aber, wenn ein Mieter fuer seine Bueroetage eine eigene, individuell steuerbare Klimaanlage wuenscht? Und was passiert, wenn andere Bueroetagen mit weiteren Klimaanlagen nachgeruestet werden? In Hamburg wurde dieses Problem auf beispielhafte ...
Total EU (and Norway) emissions of CO_2 from thermal power generation were some 950 million tonnes in 1990, the Kyoto agreement reference level. An ongoing research project, the GESTCO project, will provide the first documentation that, for the emission sources within the selected key areas, sufficient geological storage capacity is available for at least 30 years and possibly much longer. Cost of energy will obviously increase, but it is anticipated that electricity production cost price will be comparable to that of renewables. It would further have major implications for the European power generating industry which today is totally dominated by fossil fuel combustion with enormous emissions problems. The identification and siting of subsurface CO_2 storage capability can be expected to have considerable effect on the planning for and future siting of fossil fuel plants. In Norway there are plans to build several major, coastally sited, natural ...
Full text: During JET operations, tritium contaminated waste is generated principally but not exclusively from 'intervention' work and from removing or replacing redundant items. It is essential for JET and for any future fusion plant to have available a route for managing each waste stream however large or small, both during operation and decommissioning of the plant. The long term outcome is to have for each tritiated waste stream from JET a route for its management leading to its eventual disposal or recycling (and thus to be available for similar waste streams which will be produced by ITER operations). Since several years SCK#centre dot#CEN has been developing techniques for the treatment of tritiated waste. Amongst them, technologies for water detritiation, for the treatment of tritiated organic liquids and for the decontamination of several types of solid tritiated waste. Our R and D focuses on the development of a system to decontaminate surface contaminated metals, concrete ...
The proceedings include the following lectures: Facing the challenges - new structures for electricity production. Renewable energies in Europe - chances and challenges. Nuclear outlook in the UK. Sustainable energy for Europe. Requirements of the market and the grid operator at the electricity production companies. Perspectives for the future energy production. Pumped storage plants - status and perspectives. Nuclear power/renewable energies -partners or opponents? New fossil fired power stations in Europe - status and perspectives. Nuclear energy: outlook for new build and lifetime extension in Europe. Biomass in the future European energy market - experiences for dong energy. Meeting the EU 20:20 renewable energy targets: the offshore challenges. DESERTEC: sustainable electricity for Europe, Middle East and North Africa. New power plants in Europe - a challenge for project and quality management. Consideration of safely in new build ...
A statistical survey is conducted of air pollution in the city of Rome (Italy) due to conventional building space heating systems burning fossil fuels. The survey identifies the annual consumption of the different fuels and the relative amounts of the various pollutants released into the atmosphere by the heating plants, e.g., sulfur and nitrogen oxides, carbon monoxide, etc. Comparisons are then made between the ratios of urban heating plant air pollutants produced per tonne of fuel employed and those for ENEL (Italian National Electricity Board) coal, oil and natural gas fired power plants, in order to demonstrate the better environmental performances of the utility operated energy plants. The building space heating system energy consumption and pollution data are then used in a cost benefit analysis favouring the retrofitting of conventional heating systems with heat pump systems to obtain substantial reductions in ...
The effect of liquefied natural gas on pollutant emissions was evaluated experimentally with used and new appliances in the laboratory and with appliances installed in residences, targeting information gaps from previous studies. Burner selection targeted available technologies that are projected to comprise the majority of installed appliances over the next decade. Experiments were conducted on 13 cooktop sets, 12 ovens, 5 broiler burners, 5 storage water heaters, 4 forced air furnaces, 1 wall furnace, and 6 tankless water heaters. Air-free concentrations and fuel-based emission factors were determined for carbon monoxide, nitrogen oxides, nitrogen dioxide, and the number of (predominantly ultrafine) particles over complete burns?including transient effects (device warm-up and intermittent firing of burners) following ignition--and during more stable end-of-burn conditions. Formaldehyde was measured over multi-burn cycles. ...
Contents: Introduction; Design Criteria for a Green Building; Comparison of Energy Efficiency Measures; Whole House Energy Efficiency; Built Examples of Energy Efficient Houses; and Product Energy of Building Elements.
This paper reviews three key initiatives undertaken in the historical city of Oxford to bring about reductions in energy-related CO_2 emissions on a city-wide scale. The author has been part of all the three initiatives. In 2002, a collaborative partnership between academia, industry and city council started the Oxford Solar Initiative (OSI) which uses a community-based approach to help households and organisations in Oxford, financially and technically, to install solar energy systems and energy efficiency measures in buildings. So far OSI has facilitated the installation of 80 active solar systems, over 450 energy efficiency measures and 3,000 low energy bulbs. The scientific basis of OSI is a GIS-based DECoRuM model which estimates and maps baseline energy use and CO_2 emissions on a house-by house level, identifies 'pollution' hotspots, predicts the potential for reductions in CO_2 emissions and monitors reductions ...
The Dalia field is located 210 km north west of Luanda (Angola), about 140 km from shore in 1400 meter water-depth. It was the second major discovery out of 15 made in the block 17 operated by Total. The Dalia Umbilical, Flow lines and Risers EPCI Contract was awarded in 2003. The sea-line network to connect and control the 71 wells and 9 manifolds consist of the following: 40 km of insulated pipe in pipe (12 inches into 17 inches) production flow lines; 45 km of 12 inches water and gas injection lines; 6 off 1.7 km flexible water and gas injection risers; 8 off 1.65 km flexible Integrated Production Bundle (IPB) risers; 75 km of control umbilicals. The flow assurance and associated insulation requirement of the production transport system was one of the main challenges of the project. With a crude temperature of 45 deg C at the wellhead and the required minimum temperature of 35 deg C on arrival at the FPSO, this problem was complex. ...
During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 MV. (author)
This paper considers the technical progress in offshore pipeline construction with limitation to some general subjects covering pipeline design, installation and start-up. In future the use of limit state pipeline design philosophy, may be implemented as an alternative to the stress based design commonly used to day giving a potential for further optimisation of the pipeline design and consequently reduction of the initial investment. Comprehensive research and development efforts in Norway in the second half of the 1970`s, made it technically feasible to cross the deep water Norwegian Trench in the 1980`s. In addition, the development of several offshore pipeline systems until to day including gas distribution systems to the European continent, have brought Norway to the forefront of technical expertise
A series of tests was recently completed at the 400-MW (thermal) Fast Flux Test Facility (FFTF) to further demonstrate the passive safety characteristics of liquid-metal-cooled fast reactors. Earlier FFTF testing of decay heat removal by sodium natural circulation was reported in 1981. The main purpose of the 1986 test series was to demonstrate passive reactor shutdown during a loss-of-flow event when several inherent shutdown devices called gas expansion modules (GEMs) were installed in the reactor. However, these tests also provide further data on the natural circulation performance of the primary system, in particular the reactor core, and thus add to the data base available for checking the validity of available analytical tools.
Adding capacity to coal-fired plants in small increments of an overall integrated program may be the solution to the 10-year lead time required for the construction of a new plant. A preliminary study evaluates the technical and economic feasibility of a modular natural gas and coal-fired combined-cycle power plant which can be installed in three distinct phases. The plant sizes are suitable for large industrial and utility applications. The Modular Block Power Plant (MBPP) concept offers the advantages of phase construction, lower capital cost, lower cost electricity, lower air emissions, lower water requirements, and reduced solid waste discharge. Other advantages include part load availability, reduced coal inventory requirements, and easier plant siting. 11 figures, 4 tables.
The phased field development of the Lion and Panthere fields, offshore the Ivory Coast, includes a small floating production, storage, and offloading (FPSO) tanker with minimal processing capability as an early oil production system (EPS). For the long-term production scheme, the FPSO will be replaced by a converted jack up mobile offshore production system (MOPS) with full process equipment. The development also includes guyed-caisson well platforms, pipeline export for natural gas to fuel an onshore power plant, and a floating storage and offloading (FSO) tanker for oil export. Pipeline export for oil is a future possibility. This array of innovative strategies and techniques seldom has been brought together in a single project. The paper describes the development plan, early oil, jack up MOPS, and transport and installation.
A 1 MWe power plant using waste wood fuel is to be installed at a US Marine Corps base, which will supply all wood from a landfill site. The core energy conversion technology is a down-draft gasifier supplying approximately 150 Btu/scf gas to both spark ignition and diesel dual-fuel engine-generator sets. Features of the plant design include: (1) grinding wood fuel from a wide range of waste resources, (2) specialized screening for fines removal, (3) complete tar and other waste product control without landfill disposal, and (4) use of process heat for bulk fuel drying, gasifier air pre-heating, and wastewater evaporation.
In seeking ways to reduce emissions from two-stroke locomotive type engines, the Navy has evaluated dual-fuel conversions operating on a compression ignition cycle, using up to 94% natural gas and 6% diesel pilot fuel. The Navy has conducted an evaluation and test program under the direction of Dr. Normnn L. Helgeson, at the Naval Facilities Engineering Service Center in Port Hueneme, California. Of the Navy`s many diesel engines, those installed in its MUSE (mobile utility support equipment) units for temporary electrical power were the first Navy off-road engines to be affected by emissions regulations. Most of the units are powered by the EMD 645 engine, and when burning diesel fuel do not meet the emission requirements in many areas of the country. This paper discusses the changes and results of the conversion and shakedown tests.
The thermal analysis of a turbine stack discharging exhaust gases to the atmosphere is presented. The examined turbine stack belongs to a gas lift plant for oil extraction located in the Gulf area. The analysis has been performed because an overheating of the anchor flange/bolts and of the concrete foundation occurred and caused small cracks in the upper layer of the foundation. A qualitative thermal analysis of the stack has pointed out that the main cause of the overheating was the thermal radiation in the air-filled region underneath the stack bottom plate. Detailed calculations performed by using a CFD code (Fluent ver. 6.0.12), cross-checked with measurements taken from site, have shown that a significant reduction of the heat flux to the foundation could be obtained by filling the above mentioned air region with an insulating material. The benefits of this solution are prevailing over those achievable with the installation of external ...
Abstract Steam generation is an integral part of most chemical process plants; however, the steam plant often is or can be overlooked in the area of hazard analysis. The reasons for this oversight are obvious: steam generation is considered to be an old and well-understood process, and steam boiler systems are often not considered to pose the same hazards as other plant units. However, modern steam boiler systems are fueled with natural gas, pulverized coal, and/or fuel oil; each of which poses significant fire and explosion hazards. For example, a moderately sized chemical plant's boiler house may have two or three boilers operating at 240 MMBTU/hr, with each using approximately 11 ton/hr of subbituminous pulverized coal feed. Chemical plants rely on equipment design and installation, mai...
This is a build-and-scrap-and-build job, in which a new No. 1 generator is constructed while the existing plant stays in operation in the same site. Since interference between the new and the existing systems are unavoidable in such work, protection is sufficiently provided and measurements are frequently performed when the work comes to involve important structures positioned close to each other, such as the existing No. 1 and No. 2 OF (oil-filled) cables transmitting power from the existing power plant to Minami-Yokohama Substation of Tokyo Electric Power Co., Ltd., and the newly planned discharge channel or the existing covered sewerage and the newly planned discharge outlet. Now that the newly planned discharge channel intercepts the OF cables at three places and is installed to pass under the existing cable duct, it once happened that the duct supporting piles were severed for the cables to suspend in the air though temporarily. During ...
The Conference on Building Design and Architecture organized by Swedish Council for Building Research Contents included articles on building physics, thermal-climate technology, and building location and planning.
A research report presents the basic data required when designing a building with minimal environmental impacts. Topics covered include the energy consumption of building elements during their lifetime, the environmental implications linked to the extraction and processing of building material and the energy consumed in buildings by the occupants. (UK)
Within the framework of efforts to optimize state-of-the-art waste disposal methods, this research project makes a theoretical analysis of the propagation behaviour of pollutants from landfills and waste incineration plants into the immediate vicinity of such plants. In order to judge the propagation of pollutants near the above-mentioned waste disposal facilities, a calculation program was developed within the framework of this research project which permits simulation of the propagation of such emissions in a three-dimensional space by application of an Eulerian grid model. It is capable of realistically representing fluid flow conditions and pollutant concentrations for certain points of times within the complex building patterns of such plants, for randomly chosen atmospheric conditions. (orig.)
We suggest and study designed defects in an otherwise periodic potential modulation of a two-dimensional electron gas as an alternative approach to electron spin based quantum information processing in the solid-state using conventional gate-defined quantum dots. We calculate the band structure and density of states for a periodic potential modulation, referred to as an antidot lattice, and find that localized states appear, when designed defects are introduced in the lattice. Such defect states may form the building blocks for quantum computing in a large antidot lattice, allowing for coherent electron transport between distant defect states in the lattice, and for a tunnel coupling of neighboring defect states with corresponding electrostatically controllable exchange coupling between different electron spins.
This paper presents a mathematical model for simultaneous heat and moisture transfer under freezing-thawing in porous hygroscopic material. Even below O{sup o}C, unfrozen liquid water exists in the material which plays an important role in the processes. The model takes into account the existence of unfrozen liquid water. The system is treated as a three-(gas, liquid and solid) phase system of water. Moisture chemical potential is used as a moisture potential. Under freezing, moisture chemical potential is a unique function of local temperature. So, during freezing, two unknown variables to be solved are solid water content and moisture potential or temperature. A simple example of simulation for freezing processes is shown. (author)
This paper explores the potential of solid oxide fuel cells (SOFCS) as 3--10 kW auxiliary power units for trucks and military vehicles operating on diesel fuel. It discusses the requirements and specifications for such units, and the advantages, challenges, and development issues for SOFCS used in this application. Based on system design and analysis, such systems should achieve efficiencies approaching 40% (lower heating value), with a relatively simple system configuration. The major components of such a system are the fuel cell stack, a catalytic autothermal reformer, and a spent gas burner/air preheater. Building an SOFC-based auxiliary power unit is not straightforward, however, and the tasks needed to develop a 3--10 kW brassboard demonstration unit are outlined.
Back in 1985 it was the European Commission's intention to demonstrate on rather large scale the provision of clean and renewable energy with hydrogen as energy vector and fuel. The cheapest and technologically available form of renewable electricity, the primary energy for electrolytic hydrogen, is hydropower. Most of the hydroenergy sources are oversea's. The World's topologically and technically exploitable hydroenergy potential is estimated to be in the order of 20.10{sup 3} TWh/y, i.e. 0.0057% of the hydraulic cycle energy. Today's hydroelectricity generation is {approx}2500 TWh/y i.e. {approx}21% of the World's electricity generation. Quebec's installed hydroelectricity is 33.5 GW, its residual potential is 50 GW or 190 TWh/y and 285 TWh/y, respectively (load factor 0.65). The construction of hydropower installation is rather clean. The construction of La Grande at James Bay with an ...
The present project examined the operating characteristics and application possibilities of a new, compact combined heating and electricity generating unit with a thermal output of 14,5 kW and a generating capacity of 5,5 kW. Such a module was installed in a plant in Arlesheim (Canton of Basel-Country) and subject to performance measurements. The small heating and generating plant is designed for cyclic operation (without heat storage) and is very compact and low in cost. The heating and generating unit conforms to all Swiss regulations relating to electrical installations and air pollution control. The NO{sub x} emissions of the unit (400 mg/m{sup 3} in steady state operation) are above the limits of LRV 92 (80 mg/m{sup 3}), but the regulation does not apply for units in this power range. The electricity generation costs are approximately CHF 0.16/kWh. It therefore makes sense to install the module in regions with average ...
An outline of Manitoba Hydro's Earth Power program was presented. Details of the heat pump market in Manitoba were provided, including details of residential and commercial sales. Total residential heat pump sales amounted to 577 units in 2004, equivalent to over $11.2 million in sales. Commercial installations amounted to approximately $12.7 million. An outline of industry players was presented. The goals of Manitoba Hydro were outlined in relation to geothermal energy and the Power Smart program. Their objectives included increasing awareness of geothermal energy, making heat pumps more accessible, and improving industry infrastructure. Other objectives included educating the public about life-cycle cost implications, residential loans and commercial incentives. To date, the residential power loan has provided financing to over 300 Manitoba home owners for installations, with electrical savings of over 1.34 Gwh and natural ...
Within the United Kingdom, the regulatory body having responsibility for the licensing of nuclear installations is the Health and Safety Executive (HSE). The Nuclear Installations Inspectorate (NII) is that part of HSE which administers this function. Discussions on the applicability of quality assurance (QA) to licensed sites began in 1974, and an internal report was published in 1975. In parallel with work going on at the International Atomic Energy Agency (IAEA) to prepare Quality Assurance for Safety in Nuclear Power Plants: A Code of Practice, Safety Series No. 50-C-QA, NII published a second report in 1978 entitled A Guide to the Quality Assurance Programme for Nuclear Power Plants. In 1980, the construction of advanced gas cooled reactors at Heysham 2 and at Torness was licensed, and a condition was attached to the licences requiring the licensees to submit their QA arrangements to the NII for approval. The ...
An effective procedure for removing _3H, Xe and Kr from irradiated fuels was demonstrated using Shippingport UO"2 fuel. The release characteristics of _3H, Kr, Xe, and I from irradiated nuclear fuel have been determined as a function of temperature and gaseous environment. Vacuum outgassing and a flowing gas stream have been used to vary the gaseous environment. Vacuum outgassing released about 99% of the _3H and 20% of both Kr and Xe within a 3 h at 1500_0C. Similar results were obtained using a carrier gas of He containing 6% H"2. However, a carrier gas containing only He resulted in the release of approximately 80% of the _3H and 99% of both Kr and Xe. These results indicate that the release of these volatile fission products from irradiated nuclear fuel is a function of the chemical composition of the gaseous environment. The rate of tritium release increased with increasing temperature (1100 to 1500_0C) and with the ...
This report presents the work performed at the Institute of Gas Technology (IGT) during the second program quarter from October 1, 1993 to December 31, 1993, under Department of Energy (DOE) Contract No. DE-AC22-93PC92114. This program has co-ordinated funding for Task 1 from IGT`s Sustaining Membership Program (SMP), while DOE is funding Tasks 2--8. Progress in all tasks are reported. The overall objective of this research project is to develop a catalytic process to convert natural gas to liquid transportation fuels. The process consists of two steps that each utilize catalysts and sulfur containing intermediates: (1) to convert natural gas to CS{sub 2} and (2) to convert CS{sub 2} to gasoline range liquids. Experimental data will be generated to demonstrate the potential of catalysts and the overall process. During this quarter, progress in the following areas has been made. An existing unit at IGT was modified to ...
Oregon State University (OSU) and the Pacific Northwest National Laboratory (PNNL) were funded by the U.S. Department of Energy to conduct research focused on resolving the key technical issues that limited the deployment of efficient and extremely compact microtechnology based heat actuated absorption heat pumps and gas absorbers. Success in demonstrating these technologies will reduce the main barriers to the deployment of a technology that can significantly reduce energy consumption in the building, automotive and industrial sectors while providing a technology that can improve our ability to sequester CO{sub 2}. The proposed research cost $939,477. $539,477 of the proposed amount funded research conducted at OSU while the balance ($400,000) was used at PNNL. The project lasted 42 months and started in April 2001. Recent developments at the Pacific Northwest National Laboratory and Oregon State University suggest that the performance of ...
CRE is the French commission for energy regulation. CRE's remit is to assist in ensuring the proper operation of the electricity and natural gas markets for the benefit of the end-user. In particular, CRE ensures that the conditions of access to electricity and natural gas transmission and distribution systems do not hinder the development of competition. It monitors, for the electricity and natural gas sectors, all transactions made between suppliers, traders and producers, all transactions made on the organised markets and cross-border trading. It ensures that suppliers, traders and producers propose offers that are consistent with their financial and technical constraints. It monitors the implementation of and compliance with regulations giving consumers the right to choose their supplier in a competitive market, and allowing new suppliers to enter the market. This document is the 2008 activity report of CRE. ...
The nuclear power industry has experienced four carbon based adsorbent fires in its history, one was of the Monticello Standby Gas Treatment System and other three were in various off-gas delay beds. Although, some of the latter may not be classified as a full fledged fires. There were a number of experiments performed relating to igniting carbon beds and experiments relating to attempts at extinguishing set fires reported in the literature. Review of these experiments indicates that fire resulting from decay heat of adsorbed radioactive iodine is not justified even under the somewhat unrealistic source terms still in effect. At the same time the non-nuclear chemical industry application of carbon base adsorbents for solvent recovery has resulted in numerous fires and significant property losses. Fire control systems installed in nuclear air cleaning systems in the US consists of water deluge. Accidental initiation of these ...
The present article describes the features of the fully-fired combined cycles and the outline of the plant. Hitachi has optimized fully-fired combined cycle systems by executing a heat recovery type combined cycle. For the fully-fired combined cycles, it is possible to raise plant efficiency through the selection of adequate gas turbine types and cycles. It is possible to apply existing boiler facilities, fuel combustion systems, and stacks. It is possible to execute civil and architectural works on existing plants in-service as well as modification works during routine inspections. The NOx increment by gas turbine unit installations can be reduced by denitration plant modifications. Examples of the fully-fired combined cycles under planning are also introduced. Furthermore, the relational technique and operational characteristics are mentioned, as for combustion characteristics under low oxygen concentration in the wind ...
The recent attempt to degassify a self contained liquid filled (SCLF) cable in Ontario Hydro is described. In September 1989, there was a high pressure alarm on one phase of a SCLF 115 kV cable circuit. The direct buried cable circuit is about 1,890 m long with two joints and was installed in 1968. Oil samples from the cable had 10 to 12% gas content with high levels of hydrogen, methane, and ethane, and very low levels of carbon monoxide, carbon dioxide, and acetylene. From these results it was concluded that the gas was generated by low energy electrical discharges and the paper insulation was not degraded. Various utilities and cable manufacturers were contacted to find if they had experienced similar problems. The cable duct oil was flushed and gasified and the successive oil samples were analyzed in order to locate the gassing site. The joints were examined and oil samples were taken through holes drilled in the cable ...
A generalized approach to the analysis of the effects of transmission line faults on natural gas transmission pipelines has been developed and is presented in this report. A state of the art user-friendly computational tool has been developed and verified for the analysis of interference between electrical power lines and nearby buried or above-ground pipelines. This computer program, ECCAPP, is distinguished by its ability to model and analyze accurately complex, realistic interactions between pipelines and power lines, using easily obtained input data. The final report consists of three volumes. An independent fourth volume was also developed to simplify the installation of the ECCAPP software. This report, volume 1, contains the theory upon which the ECCAPP computer program is based. A parametric analysis and graphical charts have been formulated using ECCAPP to permit estimates to be made in the field or during preliminary analyses for ...
A cooling system was developed which could be used even in such areas where the maximum and minimum temperatures of a day might differ widely. The system features in that a latent heat storage unit is connected to the natural circulation cooling unit consisting of 2 heat exchangers where condensed gas (refrigerant) which performs gas-liquid change has been sealed, enabling to cool objects night and day without the requirement for any power source. Electronic equipment was installed in an insulated shelter. Lauric acid and refrigerant R-22 were used as the latent heat storage medium and the heat transport medium respectively. Natural convection heat transfer performance of the outside surfaces of the condenser and the evaporator and the transient behavior of the system during the melting and solidification periods of the latent heat storage medium were tested. As a result of a 48 hour simulation experiment with load ...
To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact ...
The DOETRAN model is a DSM database manager, developed to act as an intermediary between the whole building energy simulation model, DOE-2, and the DBEDT DSM Forecasting Model. DOETRAN accepts output data from DOE-2 and TRANslates that into the format required by the forecasting model. DOETRAN operates in the Windows environment and was developed using the relational database management software, Paradox 5.0 for Windows. It is not necessary to have any knowledge of Paradox to use DOETRAN. DOETRAN utilizes the powerful database manager capabilities of Paradox through a series of customized user-friendly windows displaying buttons and menus with simple and clear functions. The DOETRAN model performs three basic functions, with an optional fourth. The first function is to configure the user`s computer for DOETRAN. The second function is to import DOE-2 files with energy and loadshape data for each building type. The third main function is to then ...
France has committed herself to keep in 2010 the same levels of greenhouse gas emissions as those of 1990, i.e. 144 millions of tons of carbon equivalent (MtCe). However, taking into account the existing pollution abatement measures and the measurements performed so far, the greenhouse gases level should reach 160 MtCe in 2010. Therefore, the inter-ministry commission on greenhouse effect decided on November 27, 1998 to elaborate a new national plan of fight against greenhouse effect. The elaboration of the new plan has fallen under the responsibility of the inter-ministry mission of greenhouse effect (MIES). The new plan was presented by the prime minister, L. Jospin, on January 19, 2000. This document summarises the content of the new plan: architecture (modalities of elaboration, content), measures for the reduction of greenhouse gas emissions (industry, transportation sector, buildings, agriculture-forestry, wastes ...
This book describes one approach to building and operating biogas systems. The biogas systems include raw material preparation, digesters, separate gas storage tanks, use of the gas to run engines, and the use of the sludge as fertilizer. Chapters included are: (1) "Introduction"; (2) "Biogas Systems are Small Factories"; (3) "The Raw Materials of Biogas Digestion"; (4) "The Daily Operation of a Biogas Factory"; (5) "The Once a Year Cleaning of the Digester"; (6) "Tanks and Pipes: Storing and Moving Biogas"; (7) "The Factory's Products: Biogas"; (8) "The Factory's Products: Biofertilizer"; (9) "The ABCs of Safety"; and (10) "Conclusion: Profiting from an Appropriate Technology." Many diagrams are provided throughout this handbook. New ideas, composting, bioinsecticides, ferrocement, facts and figures, sources and resources, feasibility studies, problem solving, and vocabulary are presented in the appendices. (YP)
This paper evaluates a new power tower concept that offers significant benefits for commercialization of power tower technology. The concept uses a molten nitrate salt centralreceiver plant to supply heat, in the form of combustion air preheat, to a conventional combined-cycle power plant. The evaluation focused on first commercial plants, examined three plant capacities (31, 100, and 300 MWe), and compared these plants with a solar-only 100-MWe plant and with gas-only combined-cycle plants in the same three capacities. Results of the analysis point to several benefits relative to the solar-only plant including low energy cost for first plants, low capital cost for first plants, reduced risk with respect to business uncertainties, and the potential for new markets. In addition, the concept appears to have minimal technology development requirements. Significantly, the results show that it is possible to build a first plant with this concept ...
The most significant lessons provided by these developments at SASOL are the importance of long-range planning and the need for establishing a commercialized technology base in synfuels. These are necessary to reduce our dependence on foreign energy sources and can be accomplished with suitable cooperation between government and private industry and between agencies within the government. The Fischer-Tropsch process is not the only method for producing gasoline from coal, but so far it is the only one commercially proven. Another process, which produces gasoline from methanol, has been considered for commercialization. The government of New Zealand decided in December 1979 to build a commercial-size plant using its abundant natural gas as the feedstock in a natural gas to methanol to gasoline process. Because methanol can also be produced from gasified coal, this process may be an attractive option for the production of ...
The most significant lessons provided by these developments at SASOL are the importance of long-range planning and the need for establishing a commercialized technology base in synfuels. These are necessary to reduce our dependence on foreign energy sources and can be accomplished with suitable cooperation between government and private industry and between agencies within the government. The Fischer-Tropsch process is not the only method for producing gasoline from coal, but so far it is the only one commercially proven. Another process, which produces gasoline from methanol, has been considered for commercialization. The government of New Zealand decided in December 1979 to build a commercial-size plant using its abundant natural gas as the feedstock in a natural gas to methanol to gasoline process. Because methanol can also be produced from gasified coal, this process may be an attractive option for the production of ...
... 2010-10-01 2010-10-01 false Battery installation. 393.30 Section 393.30...Devices, and Electrical Wiring § 393.30 Battery installation. Every storage battery on every vehicle, unless located in...
TransCanada Pipelines Limited submitted an application to the National Energy Board for new facilities to increase natural gas deliveries to its domestic and export markets. The proposed facilities consist of 1,590 km of pipeline, 21 new compressor units and two new compressor stations. The total cost of the facilities was estimated at $2,408 million. The Board considered at the hearing 15 applications made pursuant to Part IV of the National Energy Board Act for gas exports at existing delivery points at Emerson and Niagra Falls as well as at proposed new delivery points at Chippawa and Iroquois, Ontario. Twelve of these applications were filed in support of TransCanada's facilities application. Five applications were also filed pursuant to section 71 of the National Energy Board Act for orders requiring TransCanada to receive, transport and deliver natural gas offered by the applicants and to provide adequate and ...
This fourteenth quarterly technical progress report of the MHD Integrated Topping Cycle Project presents the accomplishments during the period November 1, 1990 to January 31, 1991. Testing of the High Pressure Cooling Subsystem electrical isolator was completed. The PEEK material successfully passed the high temperature, high pressure duration tests (50 hours). The Combustion Subsystem drawings were CADAM released. The procurement process is in progress. An equipment specification and RFP were prepared for the new Low Pressure Cooling System (LPCS) and released for quotation. Work has been conducted on confirmation tests leading to final gas-side designs and studies to assist in channel fabrication.The final cathode gas-side design and the proposed gas-side designs of the anode and sidewall are presented. Anode confirmation tests and related analyses of anode wear mechanisms used in the selection of the proposed anode ...
This fourteenth quarterly technical progress report of the MHD Integrated Topping Cycle Project presents the accomplishments during the period November 1, 1990 to January 31, 1991. Testing of the High Pressure Cooling Subsystem electrical isolator was completed. The PEEK material successfully passed the high temperature, high pressure duration tests (50 hours). The Combustion Subsystem drawings were CADAM released. The procurement process is in progress. An equipment specification and RFP were prepared for the new Low Pressure Cooling System (LPCS) and released for quotation. Work has been conducted on confirmation tests leading to final gas-side designs and studies to assist in channel fabrication.The final cathode gas-side design and the proposed gas-side designs of the anode and sidewall are presented. Anode confirmation tests and related analyses of anode wear mechanisms used in the selection of the proposed anode ...
The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, 3, 4, a series of leak detection capability tests was ...
The Conference on Building Design and Architecture organized by Swedish Council for Building Research Contents included articles on building physics, thermal-climate technology, indoor-air-quality technology, construction materials, quality assurance, and building policy and regulation.
USGS scientists Laura Clor and Tim Moloney installing a temperature sensor under a public boardwalk in Norris Geyser Basin, Yellowstone National Park....
A survey is given on the results in hand on the natural radioactivity of building materials. It is shown that only a small percentage of building materials has an increased content of radioactive materials. The results are compared with approximate values given in a Russian publication. (orig./AK).
;Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.
The development of comfort in buildings throughout the centuries was influenced by the demand for progress, wealth and innovation in various respects. At present, it seems that progress may only be possible by taking into account the environment and creat...
Contents: Energy Use; Building Fabric Performance; Ventilation and Infiltration; Passive Solar Design; Heating Systems and Controls; Hot and Cold Water Provision; and Lighting and Electrical Appliances.
The State Energy Conservation Office has executed its first Fuel Cell Project which was awarded under a Department of Energy competitive grant process. The Texas LPG Fuel Processor Development and Fuel Cell Demonstration Program is a broad-based public/private partnership led by the Texas State Energy Conservation Office (SECO). Partners include the Alternative Fuels Research and Education Division (AFRED) of the Railroad Commission of Texas; Plug Power, Inc., Latham, NY, UOP/HyRadix, Des Plaines, IL; Southwest Research Institute (SwRI), San Antonio, TX; the Texas Natural Resource Conservation Commission (TNRCC), and the Texas Department of Transportation (TxDOT). The team proposes to mount a development and demonstration program to field-test and evaluate markets for HyRadix?s LPG fuel processor system integrated into Plug Power?s residential-scale GenSys 5C (5 kW) PEM fuel cell system in a variety of building types and conditions of service. The ...
Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only generate electricity and industrial boiler systems that only produce steam or hot water for process ...
This book contains the results of an architectural evaluation of building examples with integrated photovoltaic. Danish Building and Urban Research and Danish Technological Institute conducted the work within the framework of Solar Energy Centre Denmark. Seven examples are selected to inspire Danish architects and building owners to use PV in the building environment. The examples come from Denmark and countries (the Netherlands and Germany) with similar building traditions, climate and solar conditions. All the examples demonstrate architectural concepts that integrate photovoltaic as a natural part of the building envelope. (BA)
as manufacturing plants and laboratories, including the Chemical Laboratory at the House of David in Benton Harbor, Michigan. Built in America: Historic BuildingBuildings Survey/...
The photovoltaic (PV) industry is rapidly beginning to recognize the market potential of the buildings sector. New PV-for-buildings products have recently become commercially available, and numerous products that are under development will be introduced within the next 5 years. To ensure that these new products will be adopted and used in common building practices, the PV industry should recognize and address important buildings industry issues. These issues include building codes and standards, after-market servicing, education, and warranties and insurance policies. Photovoltaic systems are also still very expensive. The simplest method for increasing their value for a building is to decrease the building's electrical loads through energy efficiency and conservation. Meeting these goals can only be accomplished through ...
Research highlights: #-># The building occupancy affecting the cooling load prediction is studied. #-># PENN model is adopted in this study for predicting the building cooling load. #-># Statistical approach is adopted to result a less prejudice prediction performance. #-># Results show that occupancy data can significantly improve the prediction. -- Abstract: Building cooling load prediction is one of the key factors in the success of energy-saving measures. Many computational models available in the industry today have been developed from either forward or inverse modeling approaches. However, most of these models require extensive computer resources and involve lengthy computation. This paper discusses the use of data-driven intelligent approaches, a probabilistic entropy-based neural (PENN) model to predict the cooling load of a building. Although it is common knowledge that the presence ...
The paper is Part 2 of the study on the thermodynamic and thermoeconomic analyses of trigeneration system with a gas-diesel engine. In Part 1, thermodynamic and thermoeconomic methodologies for such a comprehensive analysis were provided, while this paper applies the developed methodology to an actual TRIGEN system with a rated output of 6.5 MW gas-diesel engine installed in the Eskisehir Industry Estate Zone, Turkey. Energy and exergy efficiencies, equivalent electrical efficiency, the Public Utility Regulatory Policies Act (PURPA) efficiency, fuel energy saving ratio, fuel exergy saving ratio and other thermodynamic performance parameters are determined for the TRIGEN system. The efficiencies of energy, exergy, PURPA and equivalent electrical efficiency of the entire system are found to be 58.97%, 36.13%, 45.7% and 48.53%, respectively. For the whole system and its components, exergetic cost allocations and various ...
The paper is Part 2 of the study on the thermodynamic and thermoeconomic analyses of trigeneration system with a gas-diesel engine. In Part 1, thermodynamic and thermoeconomic methodologies for such a comprehensive analysis were provided, while this paper applies the developed methodology to an actual TRIGEN system with a rated output of 6.5 MW gas-diesel engine installed in the Eskisehir Industry Estate Zone, Turkey. Energy and exergy efficiencies, equivalent electrical efficiency, the Public Utility Regulatory Policies Act (PURPA) efficiency, fuel energy saving ratio, fuel exergy saving ratio and other thermodynamic performance parameters are determined for the TRIGEN system. The efficiencies of energy, exergy, PURPA and equivalent electrical efficiency of the entire system are found to be 58.97%, 36.13%, 45.7% and 48.53%, respectively. For the whole system and its components, exergetic cost allocations and various ...
This paper describes a risk based approach and inspection planning as part of the Pipeline Integrity Management (PIM) system for the 95.5 km long 18'' GASVOL gas pipeline in the South eastern region of Brazil transporting circa 5 000 000 m3 dry gas per day. Pipeline systems can be subject to several degradation mechanisms and inspection and monitoring are used to ensure system integrity. Modern pipeline regulations and codes are normally based on a core safety or risk philosophy. The detailed design requirements presented in design codes are practical interpretations established so as to fulfill these core objectives. A given pipeline, designed, constructed and installed according to a pipeline code is therefore the realization of a structure, which, along its whole length, meets the applicable safety objectives of that code. The main objective of Pipeline Integrity Management (PIM) is to control and ...
The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.88 ...
An integrated multiwell floating production, storage, and offloading (FPSO) facility was successfully installed at the Tazerka field offshore Tunisia in 1982. Because there is good reason to believe that the installation techniques developed for the Tazerka FPSO can be applied to even larger systems in deeper waters, this paper presents the design and step-by-step installation procedures developed at Tazerka.
Heat pumps can be installed indoors or outdoors. H. Klein investigates which site would be preferable for a one-family house. Advantages and disadvantages with regard to necessary space, noise, maintenance and repair are discussed; heat losses in both cases of installations are dealt with. Mathematic calculation shows that indoor installation is safer and more adequate in terms of energy savings.
Three simulated low-level reactor wastes were dried using a spray dryer-baghouse system. The three aqueous feedstocks were sodium sulfate waste characteristic of a BWR, boric acid waste characteristic of a PWR, and a waste mixture of ion exchange resins and filter aid. These slurries were spiked with nonradioactive iron, cobalt, and manganese (representing corrosion products) and nonradioactive cesium and iodine (representing fission products). The throughput for the 2.1-m-diameter spray dryer and baghouse system was 160-180 kg/h, which is comparable to the requirements for a full-scale commercial installation. A free-flowing, dry product was produced in all of the tests. The volume reduction factor ranged from 2.5 to 5.8; the baghouse decontamination factor was typically in the range of 10"3 to 10"4. Using an overall system decontamination factor of 10"6, the activity of the off-gas was calculated to be one to two orders of magnitude less than ...
Within the framework of a Dutch research program on the environmental effects of coal combustion 15 measuring campaigns were carried out in the eighties. All the relevant ingoing and outgoing flows of electric power plants were sampled and the heavy metals composition was determined. An overview is given of these fifteen measuring campaigns. It is concluded that between 99.7% and 99.9% of the fly ash can be separated by electrofilters. The removal of solid elements is higher than 99%, except for those elements, which are enriched in the fly ash, f.e. Cd and Se (>90% removal is possible). Additional separation of the emissions of fly ash and elements in the fly ash takes place in a flue gas desulfurization (FGD) installation. Some elements are emitted as gaseous wastes. After the electrofilter Cl, F and I can be found for almost 100%, Br and Hg for 50% on average, and only small amounts of As and Se in the gaseous phase. In a wet FGD unit ...
This is Volume 3 in a series of documents on energy efficiency of consumer products. This volume discusses energy efficiency of water heaters. Water heaters are defined by NAECA as products that utilize oil, gas, or electricity to heat potable water for use outside the heater upon demand. These are major appliances, which use a large portion (18% on average) of total energy consumed per household (1). They differ from most other appliances in that they are usually installed in obscure locations as part of the plumbing and are ignored until they fail. Residential water heaters are capable of heating water up to 180{degrees}F, although the setpoints are usually set lower.
This report presents a reassessment of the design of Resistive Cryogenic Cable Systems with regard to dielectric material selection, thermal insulation selection, conductor design, and refrigeration subsystem design. An algorithm using test data generated as part of the program and available from the literature was developed and used to assess the driving parameters for system cost analysis. The results of this cost sensitivity analysis are presented. An electric utility, Public Service Electric and Gas of New Jersey (PSE and G), performed an economic viability evaluation comparing two selected Resistive Cryogenic Cable Systems to a conventional cable system (high pressure oil-filled). The comparison was made for a 35-mile network application on the PSE and G transmission system scheduled to be placed in service in 1995. Consideration was given to equipment capital, installation, and operating costs. It was concluded that a Multilayer Vacuum ...
When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University lead slowing-down ...
Considerations were given on typical applications of nylon resin parts to automotive use and their future trends through news topics. GF strengthened nylon resin is used in cylinder head covers substituting aluminum because of advantages in nylon resin of weight reducibility, vibration suppressibility, and noise shielding capability. Radiator tank uses N66GF 30% strengthened nylon in more than 60% of bonnet type passenger cars. Nylon resin is used most in harness connectors installed in locations that require heat resistance. External car parts such as bumpers, fenders, and wheel caps use to some extent nylon resin in the form of strengthened and up-graded polymer alloy. BMW in Germany used in its high-class production cars intake manifolds made of GF strengthened Nylon 66. The majority of engine{prime}s gas intake system parts has been replaced with Nylon blow-formed parts. The resin industry is aiming at developing Nylon resin with aromatic ...
Currently, high temperature filter systems are in the demonstration phase with the first commercial scale hot filter systems being installed on integrated gasification combined cycle (IGCC) and pressurized fluid bed combustion cycle (PBFC) systems (70 MW). They are dependent on the development of durable and economic high temperature filter systems. These filters are mostly ceramic tubes or candles. Ceramic filter durability has not been high. Failure is usually attributed to mechanical or thermal shock: they can also undergo significant changes due to service conditions. The overall objective of this project is to commercialize weldable, crack resistant filters which will provide several years service in advanced power processes. The specific objectives of this project are to develop corrosion resistant alloys and manufacturing processes to make Iron Aluminide filter media, and to use a ``short term`` exposure apparatus supported by other tests to identify the ...
The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration Facility and during a summer and a winter period following the successful startup and Operational phase of the completed Facility. Supplemental Monitoring includes ...
The EMP consists of a Compliance Monitoring Sampling Program and a Supplemental monitoring Sampling Program. The Compliance Monitoring Sampling Program will be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Project and during a summer and a winter period following the successful Startup and Operational phase of the completed Project. compliance monitoring consist of conducting all the sampling and observation programs associated with existing required Federal, State, and Local Regulations, Permits and Orders. These include air, water, and waste monitoring and OSHA and NESHAP monitoring. The Supplemental Monitoring Program will also be conducted during a summer and a winter Baseline periods during the Pre-Construction/Construction phases of the Demonstration Facility and during a summer and a winter period following the successful startup and Operational phase of the completed Facility. Supplemental Monitoring includes ...
A modified boundary element approach was used to analyze the response of offshore piles subjected to external soil movements. The computer model employed to solve the pile-soil problem was able to model pile head and tip loading, and loading caused by lateral movement of soil. A nonlinear pile-soil interface element with the ability to represent a hardening or softening plastic response prior to reaching an ultimate state was incorporated. With the program, 4 failure modes can be determined: flow of the soil slide past an intact stationary pile; rotation of the pile with the soil at failure along the full pile length; translation of the pile with the sliding soil, resulting in failure of the supporting soil; and the long-pile mode, in which the maximum bending moment in the pile reaches the yield moment of the pile before complete development of the other 3 modes. Theoretical solutions for a realistic hypothetical offshore pile subjected to submarine slides are presented and discussed. ...
On 24th of July 2007 Westinghouse Electric Co. signed landmark contracts with China's State Nuclear Power Technology Corporation (SNPTC), to provide four AP1000 nuclear power plants in China. The AP1000 is a two-loop 1117 MWe Pressurized Water Reactor (PWR). It is based on proven technology, but with an emphasis on safety features that rely on natural driving forces, such as pressurized gas, gravity flow, natural circulation flow and convection. Ansaldo Nucleare has provided a significant support to the passive plant technology development and, starting from 2000, is cooperating with Westinghouse to development of the AP1000 Plant. In the frame of the AP1000 Chinese agreement, Ansaldo Nucleare, in Joint Venture with Mangiarotti Nuclear, has signed a contract with Westinghouse for the design and the supply of innovative components to be installed in the first AP1000 unit to be constructed at the Sanmen site. The contract includes: the design of ...
Liquid sodium is used as coolant in Fast Breeder Reactors (FBR). There is a likelyhood of sodium spillage in ambient air in the Steam Generator Building (SGB) of the FBR plant. Due to high chemical reactivity with oxygen, especially at temperatures greater than 573 K, it catches fire very easily. In order to carryout safety related experimental studies for different modes of sodium fires and to develop suitable mathematical models for the assessment of their consequences, an experimental facility (SFEF, Sodium Fire Experimental Facility) is being setup a IGCAR, Kalpakkam. The SFEF is having a 540 m"3 volume experimental hall. Stainless steel linear will be provided on the inside surfaces of experimental hall walls, ceiling and floor. Analysis has been carried out for enclosed sodium pool fire scenarios in SFEF by using sodium pool fire code SOFIRE II, which estimates the thermal transients like pressure rise, gas temperature rise, cell wall ...
Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would have to be removed from the pit by means other than the available liquid waste connection. Remote ...
The aim of the study was to establish by means of a measuring programme how much energy for space heating can be saved by the installed hybrid system. Further, experience with the systems was to be gathered under practical use conditions. As user behaviour can influence space heating energy consumption to an extent having several times the effect of the contribution of the hybrid system, a fact that is also reported in literature, it is not sufficient to measure only space heating energy consumption. So, a unit in one of the terraced houses was scrupulously measured. In the three other terraced houses, only space heating energy consumption was measured.- This final report contains not only a description of the concepts of the buildings and hybrid system but also the energy consumptions measured, and detailed analyses of the budgets. (orig./AKF) [Deutsch] Mit Hilfe eines Messprogrammes sollte ermittelt werden, welche Heizwaermeeinsparung durch ...
Amorphous metals have an atomic structure resembling that of glass, and have high strength, toughness, and excellent magnetic properties for transformer applications. This type of metal has the potential to reduce the core losses of electromagnetic apparatus by 70-75% compared to the best grain-oriented silicon iron currently used. If all 4 million distribution transformers now in service in Canada were replaced by the more efficient amorphous units, it is estimated that over 5.25 billion kWh of energy could be saved annually. The experience of the General Electric (GE) Company and other researchers with operation of amorphous transformers is described. GE first tried operating amorphous metal transformers on a utility distribution system in April 1982. The shell-type cruciform design showed stable, low-loss performance over eight years of service. GE and the Electric Power Research Institute cooperated on manufacturing and installing 25 amorphous units at ...
MOX fuel for FBR is allowed to contain impurities within several thousand ppm, which means less than 1000 of decontamination factor (DF) in reprocessing is enough for Pu and U recycle use. The Advanced Fuel Recycle proposed by PNC is on this basis. The concept consists of innovations on both MOX fuel fabrication and aqueous reprocessing technologies based on the Purex process and it is believed that successful optimization of fuel cycle interface condition is the key issue to realize the concept. The lower DF such as 1000 can be easily obtained by the simplified Purex flowsheet which has no purification steps. However, new subject arises in MOX fuel fabrication, that is, fabrication is conducted in the shielding cell using equipment which is maintained remotely. A simplified fabrication technology becomes essential to establish the remote maintenance system and is one of the critical path for achieving the Advanced Fuel Recycle. The PNC`s proposal on the advanced fuel recycle concept ...
The MTX experiment was proposed in 1986 to apply high frequency microwaves generated by a free-electron laser (FEL) to electron cyclotron resonance heating (ECRH) in a high field, high density tokamak. As the absorption of microwaves at the electron cyclotron resonance requires high frequencies, the opportunity of applying a free-electron laser has appeal as the device is not limited to frequencies in the microwave or long millimeter wavelength regions, in contrast to many other sources. In addition, the FEL is inherently a high power source of microwaves, which would permit single units of 10 MW or more, optimum for reactors. Finally, it was recognized early in the study of the application of the FEL based on the induction linear accelerator, that the nonlinear effects associated with the intense pulses of microwaves naturally generated would offer several unique opportunities to apply ECRH to current drive, MHD control, and other plasma effects. It was consequently decided to adapt ...
This study of the hydrogeology of Chicken Creek Canyon wasconducted by the Environmental Restoration Program (ERP) at LawrenceBerkeley National Laboratory (LBNL). This canyon extends downhill fromBuilding 31 at LBNL to Centennial Road below. The leading edge of agroundwater tritium plume at LBNL is located at the top of the canyon.Tritium activities measured in this portion of the plume during thisstudy were approximately 3,000 picocuries/liter (pCi/L), which issignificantly less than the maximum contaminant level (MCL) for drinkingwaterof 20,000 pCi/L established by the Environmental ProtectionAgency.There are three main pathways for tritium migration beyond theLaboratory s boundary: air, surface water and groundwater flow. Thepurpose of this report is to evaluate the groundwater pathway.Hydrogeologic investigation commenced with review of historicalgeotechnical reports including 35 bore logs and 27 test pit/trench logsas well as existing ERP information from 9 ...
The low budgets of local governments and Federal States in Germany as well as lack of financial means of renters delaying thorough modernisation of existing heating systems in residential and public buildings, novel heat supply and related customer services are emerging on the market. Heat supply companies and housing construction associations increasingly use modern electronics and telecommunication systems for heating system upgrading and reliable operation and maintenance. This option holds an enormous potential of saving money today and in the future. Installation of remote control and maintenance systems and the related telephone-based services offer fast repair and other services via electronic telecommunications systems, thus saving money and manpower for the repair services of heat suppliers or plumbers, or financial losses due to rents being docked for broken down heating systems. Such remote control and maintenance systems however ...
The Materials & Fuel Complex (MFC) facilities 799 Sodium Processing Facility (a single building consisting of two areas: the Sodium Process Area (SPA) and the Carbonate Process Area (CPA), 799A Caustic Storage Area, and 770C Nuclear Calibration Laboratory have been declared excess to future Department of Energy mission requirements. Transfer of these facilities from Nuclear Energy to Environmental Management, and an associated schedule for doing so, have been agreed upon by the two offices. The prerequisites for this transfer to occur are the removal of nonexcess materials and chemical inventory, deinventory of the calibration source in MFC-770C, and the rerouting and/or isolation of utility and service systems. This report provides a description of the current physical condition and any hazards (material, chemical, nuclear or occupational) that may be associated with past operations of these facilities. This information will document conditions at time of ...
Growing public and political interests towards incorporating passive safety features in nuclear installations, let Siempelkamp in late 1987 propose a solution consisting of a prestressed cast-iron pressure vessel and a passive heat removal system, integrated in the reactor cell surrounding the vessel. This solution combines the inherent safety of a prestressed metallic pressure vessel with the advantages of a passive heat removal system and thus constitutes a major step towards the goal of further reducing potential residual risks. The design had to meet the boundary conditions for reactor core and reactor building of the modular 200 MWth pebble bed reactor of Siemens/-KWU. The engineering design showed that many input parameters needed for the finite-element-analysis of the overall structure required a verification by measurements in a well scaled test setup. This was especially required for the heat transfer from the liner of the prestressed ...
The advantages offered by green roofs range from improvement in architectural and landscape aesthetics to reductions in building energy costs. Seattle Public Utilities (SPU) is encouraging sustainable community development through new policies and regulations that promote green roof installation on public and commercial rooftops in Seattle's urban center. An understanding of climate-specific green roof performance is required in order to develop an accurate representation of the stormwater benefits of green roofs. This paper explored the relative importance of green roofs in storm water management and low impact development (LID) in various areas of Seattle. It also examined the relative effectiveness and applicability of green roofs under various conditions and in various parts of the city compared to other LID strategies such as Seattle's natural drainage systems (NDS) designs, swales and ponds, rain gardens, rainwater ...
In this paper an analysis will be performed to assess the economical competitiveness of Nuclear Power against other base load technologies. There are several plans to build more nuclear power plants in western countries; these plans are result among other things of the fossil fuel high prices and the concern for the global warming. France started the construction of one EPR at Flamanville in 2007 and at the end of 2008 there were 17 applications before NRC for construction and operation licenses (COL) to build as much as 26 new reactor units in USA, among the designs selected are the US-EPR, APWR, ESBWR, ABWR and AP1000. Currently, there is a lot of uncertainty about what is the overnight cost for a new generation III nuclear power plant and the vendors are not providing too much information. However, it is expected that under the new economy conditions the overnight cost will be between 2500 and 3500 USD/kW, the output electricity power of the ...
The research project's objective is to create a decision help for owners of residential buildings for several families regarding the renewal of decentralized heating and warm water preparation systems in the flats. The focus lies on a comparison of the costs of typical systems on the basis of a full cost calculation. This is done by taking into consideration the intentions of residential building companies like the reduction of additional costs to be paid by the tenants (both for social reasons and to make the flats easier to rent), low investment costs, low maintenance costs, energy saving, tenants' claims for comfort and acceptance by the tenants, economical reasons, especially regarding flats fully amortized (activation in the balance sheet). In addition to the quantitative comparison, the advantages and disadvantages of the different systems were also compared to one another from the qualitative point of view. [German] ...
This report summarizes preliminary 2-D reactive-transport simulations on the injection, storage and transport of supercritical CO{sub 2} in dolostone formations in the Ordos Basin in China. The purpose of the simulations was to evaluate the role that basin heterogeneity, permeability, CO{sub 2} flux, and geochemical reactions between the carbonate geology and the CO{sub 2} equilibrated brines have on the evolution of porosity and permeability in the storage reservoir. The 2-D simulation of CO{sub 2} injection at 10{sup 3} ton/year corresponds to CO{sub 2} injection at a rate of 3 x 10{sup 5} ton/year in a 3-D, low permeable rock. An average permeability of 10 md was used in the simulation and reflects the upper range of permeability reported for the Ordos Basin Majiagou Group. Transport and distribution of CO{sub 2} between in the gas, aqueous, and solid phases were followed during a 10-year injection phase and a 10-year post injection phase. Our results show that ...
Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to more fundamental studies of radon transport. To ascertain that results obtained with these models are of good quality, it is necessary that such models are tested. This document reports on a benchmark test organized by the EU project ERRICCA: European Research into Radon in Construction Concerted Action. The test comprises the following cases: 1) Steady-state diffusive radon profiles in dry and wet soils, 2) steady-state entry of soil gas and radon into a house, 3) time-dependent radon exhalation from a building-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive transport of radon, flux ...
A community greenhouse gas emission and energy inventory is an important tool to help local governments plan, implement and monitor climate change mitigation strategies and sustainable energy systems. Inventories can also facilitate a number of other local priorities such as air quality management; integrated land-use and transportation planning; infrastructure optimization and planning; and community economic development planning. The British Columbia government's community energy and emissions inventory initiative (CEEI) intends to collect and centralize high-quality geocoded data to generate high-value community inventories for the province's 185 local governments. This report presented strategic guidance for a comprehensive community emissions inventory system based on a high level review of international best practices. The report described the project objective and scope; guiding principles; research methodology; and inventory limitations. The report provided ...
Boxy and peanut-shaped bulges are seen in about half of edge-on disc galaxies. Comparisons of the photometry and major-axis gas and stellar kinematics of these bulges to simulations of bar formation and evolution indicate that they are bars viewed in projection. If the properties of boxy bulges can be entirely explained by assuming they are bars, then this may imply that their hosts are pure disc galaxies with no classical bulge. A handful of these bulges, including that of the Milky Way, have been observed to rotate cylindrically, i.e. with a mean stellar velocity independent of height above the disc. In order to assess whether such behaviour is ubiquitous in boxy bulges, and whether a pure disc interpretation is consistent with their stellar populations, we have analysed the stellar kinematics and populations of the boxy or peanut-shaped bulges in a sample of five edge-on galaxies. We placed slits along the major axis of each galaxy and at three offset but ...
The solar thermal production of zinc is considered for the conversion of solar energy into storable and transportable chemical fuels. The ultimate objective is to develop a technically and economically viable technology that can produce solar zinc. The program strategy for achieving such a goal involves research on two paths: a direct path via the solar thermal splitting of ZnO in the absence of fossil fuels, and an indirect path via the solar carbothermal/CH{sub 4}-thermal reduction of Zn O, with fossil fuels (coke or natural gas) as chemical reducing agents. Both paths make use of concentrated solar energy for high-temperature process heat. The direct path brings us to the complete substitution of fossil fuels with solar fuels for a sustainable energy supply system. The indirect path creates a link between today`s fossil-fuel-based technology and tomorrow`s solar chemical technology and builds bridges between present and future energy ...
The objective of this contract is to design and build a small, lightweight, stand-alone thermophotovoltaic electric generator, capable of at least 100 Watts useful output for charging 24V batteries. The prototype generator built consists of a pre-mixed burner, a cylindrical selective emitter mantle surrounded by six silicon photovoltaic concentrator arrays. The arrays are cooled with forced-air heat exchangers using self-powered fans. The generator, operated at 117,00 W (40,000 BTU/hr) of fuel input rate, produces 122 W of electrical power at 1.0% of efficiency. The cooling and pre-mix fans consume 35 W of electrical power resulting in a net 85 Watts of electrical output for charging batteries. The generator`s output is capable of continuous charging five 12/24V batteries over 10 hours with a 9.07 Kg (20 lbs.) of propane gas.
After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m"-"3, standard deviation of 44.0 Bq m"-"3 and geometric mean of 60.1 Bq m"-"3, for the radon concentration range from 23 to 186 Bq m"-"3. The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m"-"3, was in accordance with the theoretical log-normal distribution which was shown with #chi#"2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon measurement in the soil gas using radon emanators with the LR-115 film that ...
In China, the conventional utilization of oil shale is concentrated mainly on retorting oil shale to produce shale oil and fuel gas, and burning oil shale to generate electricity. The growth of petroleum price, and the development in heavy industry, make these conventional utilization facilities become unavailable on the energy market. In this paper, a new comprehensive utilization system is recommended for the future use of Huadian oil shale, based on the current status of energy and the characteristics of oil shale. The system involves three subsystems: retort subsystem, where coarse oil shale (8-80 mm) is retorted to shale oil, hydrocarbon gases and oil shale semicoke; combustion subsystem, where the mixture fuel of oil-shale semicoke and fine oil shale (0-8 mm) is fed to a circulating fluidized bed (CFB) furnace to burn, in order to generate high-pressure steam which is used to supply heat and generate electricity via a traditional steam-electric power mode; ...
The purpose of this study is to evaluate the potential benefits of applying multiseam [well] completion (MSC) technology to the massive stack of low-rank coals in the Powder River Basin. As part of this, the study objectives are: Estimate how much additional CBM resource would become accessible and technically recoverable--compared to the current practice of drilling one well to drain a single coal seam; Determine whether there are economic benefits associated with MSC technology utilization (assuming its widespread, successful application) and if so, quantify the gains; Briefly examine why past attempts by Powder River Basin CBM operators to use MSC technology have been relatively unsuccessful; Provide the underpinnings to a decision whether a MSC technology development and/or demonstration effort is warranted by DOE. To a great extent, this assessment builds on the previously published study (DOE, 2002), which contains many of the key references that underlie ...
Pacific Gas & Electric Co.`s (PG&E`s) Delta district, approximately 45 miles northeast of the San Francisco Bay Area, is a fast growing residential community with peak demand occurring between 6 and 7 PM in hot summer weekdays. In the early 1990s, PG&E`s system planners projected a need to build a new substation in 1996 to meet the local peak electricity demand. In 1991, as part of a new distribution planning and capital investment process, PG&E launched its innovative Model Energy Community (MEC or Delta) program to test whether the inclusion of new, experimental rates and geographically-targeted cost-effective energy-efficiency measures could reduce the local peak demand and therefore defer major substation and T&D capital investment. Two new residential TOU rates were designed and implemented in PG&E`s Delta area between 1991 and 1993. This paper discusses the market assessment activities and results for these rates, ...
The feasibility of developing a fusion power monitor based on a fluid activation detector is considered here. The activation fluid may be either a liquid or a gas and its composition can be selected from a number of candidate materials to provide desired activation and decay characterisitcs. Performance calculations indicate that ordinary water would be a nearly ideal activation fluid. The "1"6O(n,p)"1"6N reaction has a threshold at about 10 MeV and a cross section energy dependence giving it a predominant response for unmoderated D-T fusion neutrons. Adequate activation can be obtained at moderate flow rates for remote counting away from the high radiation area of the reactor. The 7.16 sec half-life of "1"6N is ideal for remote counting with subsequent decay in a small hold-up tank to eliminate activity build-up in the recycled water.
Low pressure silane plasmas are known for their ability to synthesize silicon nanoparticles via gas phase nucleation. While in the past this particle formation has often been considered from the viewpoint of a contamination problem in semiconductor processing, we here describe a silane low pressure plasma that enables the synthesis of highly oriented, cubic-shaped silicon nanocrystals with a rather monodisperse size distribution. These silicon nanocubes have successfully been used in the manufacture of single nanoparticle vertical transistors. We discuss the advantages of this new paradigm of building nanoelectronic devices. The plasma synthesis process is characterized in more detail than in prior work. The particle nucleation, growth and shape evolution are studied. Results indicate that the process provides two spatially distinct zones: a diffuse plasma for particle growth and a constricted plasma zone for particle annealing. Measurements of ...
This is the third of a series of research reports which builds on the previous contents which dealt with energy efficiency techniques and minimizing the environmental effects of building materials. It presents some specifications for house types and gives built examples of energy efficient homes in Europe. (UK)
A research report describes the energy efficiency techniques to be employed in designing a building which is ``green``. Topics covered include building fabric performance, ventilation and infiltration, passive solar design, heating systems and controls, hot and cold water provision, lighting and electrical appliances. (UK)
The development of comfort in buildings throughout the centuries was influenced by the demand for progress, wealth and innovation in various respects. At present, it seems that progress may only be possible by taking into account the environment and creating methods of reducing further damage to the environment. The innovative feature of future progress my be reducing the impact on the environment from human and building activities by using appropriate technology. As it is impossible to build without any impact on the environment and this is likely to be so in the future, the objective is and will be to find solutions for buildings which are more compatible with the environment. The objective is to demonstrate that it is viable to design buildings with minimized impact on the environment, while still maintaining appropriate comfort levels.
This bibliography contains citations concerning the control and mitigation of radon pollution in homes and commercial buildings. Citations cover radon transport studies in buildings and soils, remedial action proposals on contaminated buildings, soil venting, building ventilation, sealants, filtration systems, water degassing, reduction of radon sources in building materials, and evaluation of existing radon mitigation programs including their cost effectiveness. Analysis and detection of radon and radon toxicity are covered in separate published bibliographies. (Contains 129 citations fully indexed and including a title list.).
The US Department of Energy Office of Building Technology, State and Community Programs sponsored EcoTecture Solutions, Inc. (dba Sustainable Living Alliance {trademark}) in producing two home tours showcasing energy- and resource-efficient buildings in Austin, Texas, held on October 16, 1999, and Albuquerque, New Mexico, held on May 20, 2000. Lists are given of the notable building technologies, passive solar design features, and energy- and water-efficient technologies and design employed in the houses. There were over 1200 visitors to the 22 residential and 3 commercial buildings included in the tour.
Most important radionuclides naturally appearing in minerals used to form building materials are described. The frequently met ranges of concentrations of these radionuclides in the building materials composed from natural products as well as from power-plant wastes and metallurgic plant wastes are discussed and propositions concerning the limitation of presence of radioactive nuclides in the building materials are given, with special concern paid to materials for dwelling and public utility buildings. The elaborated technique of measuring potassium 40, radium 226 and thorium 228 concentrations is presented. Data on the organization of controlling-and-measuring laboratories in this field are given. (author).
Purpose of this assessment for this town in the Slovak Republic is to develop information on the building sector energy efficiency and improvement potential for use by town management to support decisions on providing energy services to Handlova citizens. Objectives were to characterize baseline space and water heat energy use and efficiency improvement potential in the residential and nonresidential building sectors. Intention was to identify major areas of efficiency improvement potential and cost-effectiveness. Four levels of energy and fuel prices were used. A significant efficiency resource exists in the space and water heating end uses in these building sectors; it amounts to 42% of the total building sector space and water heat energy consumption.
Testing of barrier properties of insulating materials against radon is usually based on the measurement of the radon diffusion coefficient. Presented report summarizes results of radon diffusion coefficients measurements in more than 120 insulating materials obtained throughout Europe. All measurements were performed by the Czech Technical University, Faculty of Civil Engineering in cooperation with the Radiation Protection Institute. We have found out that great differences exist in diffusion properties, because the diffusion coefficients vary within eight orders from 10"-"1"5 m"2/s to 10"-"8 m"2/s. For each material category of different chemical composition statistical evaluation of results is presented. Possibilities of usage of the radon diffusion coefficient for the design of radon resisting membranes are discussed. Based on the experience from the Czech Republic the paper is trying to show that controlling applicability of membranes by setting of the upper limit for the radon ...
Among the items of the Sunshine Project in fiscal 1981 for development of a solvent extraction and liquefaction plant, this paper describes the achievements in developing secondary hydrogenation. A small continuous hydrogenation device equipped with three reaction columns that can be filled with catalyst of 50 cc, and a dedicated testing room were designed, and orders were placed with manufacturers. The fabrication, assembly, delivery, installation, piping and wiring were all completed. The device passed a completion inspection based on the high-pressure gas safety assurance law in December 1981. After leakage due to gas and material oil was checked, a trial operation was performed, and verified of normal operation. A screening test was carried out on three kinds of commercially available and prototype catalysts before testing the SRC containing material for studying the secondary hydrogenation. The circulating solvent ...
A generalized approach to the analysis of the effects of transmission line faults on natural gas transmission pipelines has been developed and is presented in this report. A state of the art user-friendly computational tool has been developed and verified for the analysis of interference between electrical power lines and nearby buried or above-ground pipelines. This computer program, ECCAPP, is distinguished by its ability to model and analyze accurately complex, realistic interactions between pipelines and power lines, using easily obtained input data. The final report consists of three volumes. An independent fourth volume was also developed to simplify the installation of the ECCAPP software. Volume 1 contains the theory upon which the ECCAPP computer program is based. A parametric analysis and graphical charts have been formulated using ECCAPP to permit estimates to be made in the field or during preliminary analyses for situations that ...
The main businesses of the Aker Group were outlined. The Aker Group has an operating revenue of 51.7 billion with operational experience in deepwater floaters, subsea infrastructure, onshore oil and gas plants, fixed offshore platforms, petrochemical refining, power generation, pulping, and mining. The company plans and executes capital projects, provides technology solutions and life-cycle operations, service and maintenance. The Aker Group owns 50 per cent of the Aker Kvaener offshore drilling rig located in the North Sea. This presentation outlined the challenges of working in a harsh environment. The area is characterized by a short productive season, low temperatures and limited sunlight. The direct environmental issues include spills and the impact of oil and gas infrastructure. Indirect issues include lowering the entry barriers for other kinds of resource exploitation. Other challenges of field development in Arctic areas include ice ...
The gotten concentrations of radon-222 in the installations of the IEN had been determined using the active and passive methods. The active method consisted on the use of the alpha spectrometry with a portable equipment Tracerlab Instruments WLM- Plus. In the determination for the passive method, one used detectors of nuclear strokes of type LEXAN. The raised values had been gotten in the wastes deposit and its annexes, room of the press and laboratory of wastes handling. It was observed, in this sector, an instantaneous measure of alpha spectrometry, concentrations around 1000 Bq.m-3, which had over all to the function of storage, the sector, a great volume of natural radioactive materials, especially of radium-226. This determination was carried through in an extreme situation of ventilation zero, where the gates had been kept closed during the execution of the same one. It was observed, however, a considerable fall, with values ten times inferior, after to ...
The core bypass flow in a prismatic very high temperature gas-cooled reactor (VHTR) is one of the important design considerations which impacts considerably on the integrity of reactor core internals including operating fuels. The interstitial gaps are an inherent presence in the reactor core because of tolerances in manufacturing the blocks and the inexact nature of their installation. Furthermore, the geometry of the graphite blocks changes over the lifetime of the reactor because of thermal expansion and irradiation damage. The occurrence of hot spots in the core and lower plenum and hot streaking in the lower plenum (regions of very hot gas flow) will be affected by the bypass flow. In the present study, three-dimensional computational fluid dynamic (CFD) calculations of a typical prismatic VHTR are conducted to understand better the bypass flow phenomenon and establish the evaluation method in the reactor core using ...
This official IEA report is a deliverable of IEA SHC Task 21/IEA BCS Annex 29: Daylight in Buildings. The Task focuses on daylighting systems and strategies which can be applied in new and existing buildings with a high potential electricity saving potential such as offices, schools, commercial, and institutional buildings. The daylighting performance of these strategies and systems is tested in laboratory facilities, through modeling, and in real case study buildings. This paper provides methods and procedures to evaluate the daylighting performance of real buildings. Annex 29 case studies located in Europe, North America, and Australia. It is a deliverable of Subtask D research projects. The main objective of Subtask D, as stated in the Implementing Agreement of Task 21/Annex 29, is `to demonstrate the viability of daylighting buildings in various world ...
Researches and production of radio-isotopes, radio-pharmaceuticals and cold kits are carried out in the Radio-isotope Production Facility (RIPF). Four concrete hot cells in Bank-1 are to produce the Ir-192 source for NDT. Eleven lead hot cells in Bank-2 are to produce Ho-166, Cr-51, P-32/33, Tc-99m, Lu-177, Sr-90/Y-90 and W-188/Re-188 for research purpose. Six lead hot cells in Bank-3 are used for the production of I-131 for diagnosis and therapy of cancer in the hospital. A hot cell in Bank-3 is also utilized for the research of I-125 and Br-82. Four lead hot cells in Bank-4 are utilized for the production of Mo-99/Tc-99m generators since 2005. The major systems including the Heat and Ventilated Air Conditioning (HVAC) system and the air cleaning system such as charcoal and HEPA filter trains to filter the radioactive contaminants are in operation. So are the systems such as power supply and distribution system, UPS, fire protection system, liquid radioactive waste collection systems. ...
Heat pumps for residential space heating become an increasingly important alternative to the conventional heating system like gas or oil burner. They offer the opportunity to reduce CO{sub 2} emission associated with heating residential homes in Germany. High compressors efficiency and a wide operating map are required so that an economically viable heat pumps is achieved which meets the operational conditions for present and future heating systems. The design parameter of existing heating systems require relatively high condensing temperatures which can be achieved with dedicated compressor designs. The design of Scroll compressors specially adapted to these heat pumps is shown and their operation is explained. (orig.) [German] Waermepumpen fuer die Wohnraumheizung gewinnen an Bedeutung als Alternative zur konventionellen Gas- oder Oelheizung. Sie bieten die Moeglichkeit, die mit der Gebaeudeheizung verbundene Emission von Kohlendioxid in ...
Nanometre-sized materials, like nanowires, nanoparticles or nanobelts, are gaining huge interest as building blocks of modern electronic nanodevices. Their fabrication feasibility has been demonstrated in the last years, and different routes are already well established in order to synthesize these materials. However, the assessment of their electrical properties is still a challenging issue, due to the difficulty to perform a precise nanolithography process allowing the access to such small structures. The fabrication of metallic contacts with precision in the nanometre range is necessary, as well as achieving a flexible system that allows to contact individual structures. Such a system could be a dual-beam Focused Ion Beam instrument, which combines Scanning Electron Microscopy (SEM) and Focused Ion Beam (FIB) in one machine, able to assist deposition of materials with nanometre precision. In this work, the methodology of fabrication of metallic nanocontacts to ...
Nanometre-sized materials, like nanowires, nanoparticles or nanobelts, are gaining huge interest as building blocks of modern electronic nanodevices. Their fabrication feasibility has been demonstrated in the last years, and different routes are already well established in order to synthesize these materials. However, the assessment of their electrical properties is still a challenging issue, due to the difficulty to perform a precise nanolithography process allowing the access to such small structures. The fabrication of metallic contacts with precision in the nanometre range is necessary, as well as achieving a flexible system that allows to contact individual structures. Such a system could be a dual-beam Focused Ion Beam instrument, which combines Scanning Electron Microscopy (SEM) and Focused Ion Beam (FIB) in one machine, able to assist deposition of materials with nanometre precision. In this work, the methodology of fabrication of metallic nanocontacts to ...
Progress reports are presented for the following two areas: catalytic cracking studies with water-wet silica-alumina catalysts; and Fischer-Tropsch reactor studies where similarities and differences between fixed bed and slurry type reactors are investigated and further experiments conducted to measure mass transfer coefficients and reaction kinetics which are to be used in a model slurry reactor. The following are some of the conclusions. (1) The premise that the presence of liquid water might increase catalytic cracking activity was found to be invalid. It was demonstrated that cracking can occur at previously unobserved low temperatures (though at low conversions) and that an anomaly exists in that one of the catalysts tested shows an entirely different cracking behavior and probably follows a different cracking mechanism. (2) the diameter of a fixed-bed Fischer-Tropsch reactor critically affected the resistance of the reactor to plugging caused by the build up ...
The following paragraphs summarize the progress of each research project funded under the WVU Cooperative Agreement during the third quarter of 1997 (July - September 1997). The projects are arranged according to their 1997 WVU task number. WVU Focus Area 1.0: Subsurface Contaminants, Containment and Remediation Task No. 1.1: Project discontinued. Task No. 1.2: Development of Standard Test Protocols and Barrier Design Models for Desiccation Barriers (K. Amininan & S. Ameri): A number of experiments were preformed this period to evaluate the ability of the dried sand-packs to act as a barrier to liquids. Water infiltration tests were done with a constant head, dispersing 80 ml of water, and by adding water in small increments. Results indicate that when the water is spilled over the sand-pack, it has the tendency to channel through the sand-pack, significantly reducing the capacity of the dried zone to retain liquid contaminants. This appears to be largely influenced by particle ...
A number of buildings dating from the 1950s and 1960s were retrofitted with thermal insulation in order to cut energy consumption. This took place within the building competition 'Therma' nitrated by the Federal Ministry of Regional Planning, Building and Town Planning in 1974. Result at that time were so encouraging that now, 15 years later the results were checked again with special attention to the long-term performance of the thermal insulation measures. Laboratory tests prove that the building materials are still in good condition and that humidity has not increased with age. Cracks in the surface plaster of the compound insulation systems occurred at different frequencies and intensities and usually caused by thermal tensions. (BWI).
In accordance with federal legislation, the U.S. Department of Energy (DOE) has conducted a project to demonstrate use of its Energy Conservation Voluntary Performance Standards for Commercial and Multi-Family High-Rise Residential Buildings; Mandatory for New Federal Buildings; Interim Rule (referred to in this report as DOE-1993). A key requisite of the legislation requires DOE to develop commercial building energy standards that are cost effective. During the demonstration project, DOE specifically addressed this issue by assessing the impacts of the standards on (1) construction costs, (2) builders (and especially small builders) of multi-family, high-rise buildings, and (3) the ability of low-to moderate-income persons to purchase or rent units in such buildings. This document reports on this project.
A survey was conducted to determine the sources of buildings energy conservation case studies and educational aids available in Canada. In total 785 consultants, educational institutions, building developers, manufacturers and government agencies were contacted. The results of this survey provide an indication of those agencies in Canada most actively involved with energy conservation in buildings, a listing of those agencies in Canada having case study information and/or educational aids materials available related to energy conservation in buildings, and a broad description of the subject area of the case studies and educational aids listed. The results of this study are intended to provide a source listing of energy conservation case studies and educational aids to the Buildings Energy Technology Transfer Program lead agencies and others conducting similar studies in the ...
Requirements for the installation, inspection, and testing that assure the quality of important components of a nuclear power plant during construction are presented.
Proposal for the award of a contract, without competitive tendering, for the replacement of lift machine room equipment and the installation of remote monitoring systems
The goal of this research project was to determine the eff ects of geometric and mechanical parameters characterizing the soil-structure interaction developed in a buried pipe installation. Parameters such as pipe ring stiff ness, bedding thickness, trenc...
The installation procedure, the fabrication, fitting up, positioning, adjustment and welding of piping, examinations, hydrostatics testing and insulation of piping for reactor primary circuit piping of Daya Bay Nuclear power Plant are briefly described.
Biomass is one of the main natural resources in Sweden. The present low-CO{sub 2} emission characteristics of the Swedish electricity production system (hydro and nuclear) can be retained only by expansion of biofuel applications for energy purposes. Domestic Swedish biomass resources are vast and renewable, but not infinite. They must be utilized as efficiently as possible, in order to make sure that they meet the conditions for sustainability in the future. Application of efficient power generation cycles at low costs is essential for meeting this challenge. This applies also to municipal solid waste incineration with energy extraction, which should be preferred to its dumping in landfills. Hybrid dual-fuel combined cycle units are a simple and affordable way to increase the electric efficiency of biofuel energy utilization, without big investments, uncertainties or loss of reliability arising from complicated technologies. Configurations of such power cycles are very flexible and ...
The invention relates to a method for purifying a gas mixture containing at least one undesirable gas compound utilizing certain sulfonamide or sulfamide solvents.
The purpose of this invention is to assure operating reliability of a Mandrel head in tubes of various diameters. This goal is achieved in that it is equipped with movable expanding sectors, which are installed on a rigid conical plunger dye. It is also equipped with spring-loaded conical slides blocks which are installed on a shaft. The upper ends of the sectors of the sectorial head are attached by hinges to a rigid cone shaped plunger dye. The lower ends are installed with the possibility of interacting with the slide blocks.
The successful installation of the Europipe 16/11E Riser jacket in July 1994 and the coming installation of Sleipner T jacket in spring 1996 proves that suction installed skirted plate foundations (buckets), may not only be a competitive alternative to piles, but also a complementary foundation solution both for noncohesive and cohesive soils. This paper presents the background for the design analyses of the Europipe 16/11E and Sleipner T foundations in terms of the performed field and model tests, as well as the theoretical models and practical analysis tools utilized for design.
The dwelling is equipped with solar collectors which heat the air circulating in the cavity walls and the space beneath the floors. The thermal aspects of such a building are described. Heat balance, losses, heating by the sun in different seasons are described. Different measures taken to reduce the energy losses are described.
A nation-wide survey of natural radioactivity in building materials was conducted during 1982-1984. Samples including industrial wastes, by-products and common building materials were collected from main building material manufactories in 29 provinces except Taiwan. The results of exposure rates, specific activities and release rate for "2"2"2Rn are presented. The specific activities of common materials are listed in declining order as follows: clay bricks > common concrete and sandstones > limes and ordinary cement. The highest level was found in breeze bricks made of stone coal, phosphogypsum and red mud with high intrinsic radioactivity. Therefore, these raw materials should be strictly controlled in manufacturing building materials. The measurement results also showed that the typical specific activities of common building materials in our country were "2"2"6Ra 50 Bq/kg, ...
The following subjects are dealt with: physics of indoor air flow, flow in individual rooms, exchange of air and pollution between individual building zones and with the outside world, thermal coupling with the building shell, thermal comfort and air quality, evaluation of the ventilation. figs., tabs., refs.
Based on a generalized theory of perturbations and on non-linear programming an approach to the quantitative determination of necessary accuracies for nuclear data is described. It is used to calculate transactinide isotope build-up in reactors.
First, attention is paid to the development and use of new construction techniques, including the use of new building materials, e.g. synthetic materials and the so-called steel frame method. Next, the reduction of the energy consumption during the service life of a house is discussed. The reduction can be realized by means of passive methods, e.g. improved windows, thermal insulation and design, or by means of active methods, e.g. electric load monitoring. The information in this article mainly concerns the housing construction in the USA and Canada. The purpose of this article to contribute to the discussion in the Netherlands on innovation in the building technology, e.g. formulated in the report `Bouwvisie 2010` (Vision on Buildings for the year 2010) of the Dutch Advisory Board Technology Policy for the Building Industry (ARTB, abbreviated in Dutch) and the building technology ...
situ by isolating portions of the building envelope and performing tests .MAXIMUM ALLOWED LOAD ...and shall identify commissioning team members who will perform testing and prepare documentation.The commissioning agent may be
Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the bauxite/alumina refining industry. For the ...
An intemted approach to building a networking infrastructure is an absolute necessiry for meeting the multidisciplinary science networking requirements of ...
The risk analysis was carried out in consideration of conditions prevailing at the Kalkar site analogous to the investigations in phase A of DRS (German Reactor Study). Earthquake design loads include the probabilities of upper deviations of the site intensities to be expected. The calculations of dynamic loads for select buildings are made using models and computational methods. Component analyses were performed analogous to DRS for the supports of large components, supports of the roof construction of the reactor building taking into account support reserves due to plastic work capacity, wall disks in steam generator buildings and switchboard plant buildings. (DG).
The operation of buildings can be temporarily modified to use much less electricity. These actions may be necessary during regional electricity shortages lasting anywhere from days to months. The electricity conservation measures typically involve a combination of technical modifications, temporary changes in occupant behavior, and greatly increased vigilance. At the same time, attempts to drastically reduce a building's electricity use may have unexpected consequences affecting energy use, the indoor environment, and the performance of building materials and equipment. Electricity shortfalls such as those described in this paper may occur more often as a result of climate change and liberalized electricity markets. (author)
Ontologies ? a form of structured and logically related knowledge or classification hierarchy embedded in a computer system ? are regarded by many scientists as having enormous promise for the consistent use and re-use of data. To realise this promise, however, is not straightforward. In this paper, based on ethnographic observation, we argue that the challenges for ontology building are ?social? as much as they are technical. By this we mean the routine work undertaken in the building process and the problems and difficulties entailed can be understood in terms of the practices of knowledge workers and the practical nature of ?sorting things out?. Getting a better sense of how, in practise, this work gets done gives a sense of the main challenges of building successful ontologies and how ...
Many non-domestic buildings, built recently in the UK, use natural means to provide ventilation for indoor air quality and thermal comfort. This paper presents monitoring results obtained from such a purpose built naturally ventilated educational building. Its performance during the summer is discussed based on monitored results. Using thermal and ventilation modelling, the paper also discusses the optimisation of the building's summer performance. Recommendations on the selection of appropriate ventilation strategies in relation to the prevailing external conditions are derived and the appropriateness of the control methods is discussed. (author)
During its jubilee, the French building technical and scientific centre (CSTB) has organized a colloquium about the future tendencies of buildings evolution in the 20 forthcoming years: autonomy in energy production and wastes or effluents management, reduction of water consumption and management of water, hot water production and space heating, bio-sensors for the management of indoor air-quality, control of noise environment using active acoustic systems etc.. (J.S.)
In the discussion of environmental architecture, we are conjoining two disciplines, the subject of architecture and that of ecology. At their best, green buildings are examples of applied ecology, where designers understand the constitution, organization, and structure of ecosystems, and the impacts of architecture are considered from an environmental perspective. By utilizing the concepts, methods, and language of ecology, designers can create architecture that intentionally engages the natural systems of a site. The establishment of assessment criteria implies the definition of building design criteria. If we establish criteria that are based on our best scientific understanding of environmental capacity, we will begin to develop a building stock that is sustainable. To do this we must quantify the link between the resulting environmental impacts and their cause in building production and use. This is ...
The preliminary results of a feasibility study of nighttime and/or daytime accelerated ventilation for reducing or even avoiding air conditioning energy consumption in commercial buildings, is presented. The first part of the study is based on computerized simulations and in-situ experimentations which are described. The second part is aimed at determining technological limitations to the various components and optimizing building environmental quality in terms of energy conservation, acoustics and air quality
In this study, a probabilistic seismic risk analysis of the Wolsung NPP containment building was performed by a seismic hazard analysis and a seismic fragility analysis based on the nonlinear dynamic time-history analyses. The conventional seismic fragility analysis of the safety related structures in a NPP have been performed by using the linear elastic analysis results. The probabilistic seismic risk of the containment building was 5.19e-8.
In this study, a probabilistic seismic risk analysis of the Wolsung NPP containment building was performed by a seismic hazard analysis and a seismic fragility analysis based on the nonlinear dynamic time-history analyses. The conventional seismic fragility analysis of the safety related structures in a NPP have been performed by using the linear elastic analysis results. The probabilistic seismic risk of the containment building was 5.19e-8.
This report provides a detailed description of, and the baseline assumptions and simulation results for, the building prototype simulations conducted for the building types designated in the Work Plan for Demand-side Management Assessment of Hawaii`s Demand-Side Resources (HES-4, Phase 2). This report represents the second revision to the initial building prototype description report provided to DBEDT early in the project. Modifications and revisions to the prototypes, based on further calibration efforts and on comments received from DBEDT Staff have been incorporated into this final version. These baseline prototypes form the basis upon which the DSM measure impact estimates and the DSM measure data base were developed for this project. This report presents detailed information for each of the 17 different building prototypes developed for use with the DOE-21E program (23 ...
The present study answers at the request of the Inspection of the classified installations to see the operator of the G.I.P. Cyceron setting up a plan of environmental radiological surveillance around its installations and including, at a minimal level, the following data: Measures of radioactivity on representative biological indicators and measures of dose rate in the environment close to installations in functioning. Further to the radiological assessment of the terrestrial environment of the G.I.P. Cyceron installations realized at the end of 2003, within the framework of a project of the installations extension, the A.C.R.O. was again required for the implementation of this radiological surveillance for year 2005. The first purpose is to supply elements of appreciation about the impact of these installations on environment and persons. This evaluation ...
A publication on Norwegian gas and gas export. The content is wide spread from use of gas in daily life via sub sea pipeline repair systems to an overview over tomorrows gas fields. (AG)
This paper seeks to challenge the traditional way in which we assess the value of green buildings in terms of their environmental friendliness, energy efficiency and whole life cost. In the UK, quantity surveyors (or cost consultants) have a perception that more energy efficient and environmentally friendly buildings cost between 5% and 15% more to build from the outset. This common assumption is not backed up by recent research and should be questioned. Construction professionals need to be informed of the whole life cost and environmental impact of buildings so that they can encourage key stakeholders to make more sustainable choices. These emerging issues together with practical tools are considered with case studies from recent projects. (Author)
Today's building industry is promoting the use of renewable sources of energy to heat, cool, and illuminate commercial buildings. Societies such as the International Solar Energy Society sponsor conferences such as this one to share knowledge and experience in the area of solar energy. However, the technologies presented here assume a need for heating, cooling or illumination. A simple technique is presented for determining the actual heating, cooling, and lighting requirements for commercial buildings, and for reducing those requirements through proper building design before applying solar technologies. The energy nomographs are a graphic energy design tool developed to aid designers in making cost effective decisions about energy alternatives early in the design process. Reducing loads at this point can help reduce the expense of a passive or active solar system which is usually sized to meet ...
This book brings together the 103 presentations given at the 2. conference of the international institute of refrigeration (IIF/IIR) about air conditioning in high rise office buildings. The main themes are: design of air conditioning equipment for high buildings; air quality and thermal comfort inside these buildings; constraints and possible improvements of the refrigeration equipment used; energy conservation; fire protection and smokes detection. All themes are presented both on the technical and economical points of view and concern more particularly the buildings of Chinese cities. This publication is available both on the book and CD-Rom forms. (J.S.)
This report describes work carried out in the context of TurboTech Interim for the development of a system for monitoring stationary gas turbines for approaching the stability limit of the compressor. The requirements for the system components were defined and the suitability of different types and positions of pressure sensors were examined and evaluated. It was found very early in the work that, due to the complexity of the object being monitored, one would not succeed in finding a simple criterion for monitoring the pump limit. Rather, apart from the selection of suitable sensors and optimum positions, one must analyse the present signals in different ways and create a decision matrix from this. Existing work on this subject is mostly concerned with the phenomena in the context of experiments on experimental compressors or is not suitable for the requirements of stationary industrial gas turbines. The project is being carried out in the ...
Green building (GB) is part of the concept of promoting sustainability. Although GB and the concept of sustainability are well studied for environmental concerns, their business rationale and related social concerns have not been fully explored or widely accepted by the parties involved in the building sector. In this study, the situation of GB market in relation to the general building market is reviewed and the business rationales of stakeholders to invest in the GB market have been investigated from the perspective of building designers. In addition, the factors that enhance the popularity of GB have been explored and the obstacles that hinder its market have been examined. The data are collected by a questionnaire survey covering building designers in Hong Kong and Singapore, the cities that are categorized as economically developed cities in Asia. After data analysis of the ...
Because there are more than 101 million residential households in the United States today, it is not surprising that existing residential buildings represent an extremely large source of potential energy savings. Because thousands of these homes are renovated each year, Building America is investigating the best ways to make existing homes more energy-efficient, based on lessons learned from research in new homes. The Building America program is aiming for a 20%-30% reduction in energy use in existing homes by 2020. The strategy for the existing homes project of Building America is to establish technology pathways that reduce energy consumption cost-effectively in American homes. The existing buildings project focuses on finding ways to adapt the results from the new homes research to retrofit applications in existing homes. Research activities include a combination of computer ...
In this work a flat receiver of self construction is shown with relatively low cost and easy manufacture, but with a thermal efficiency superior to 40% for applications at temperatures less than 60 degrees Celsius, that allows satisfying international standards in this respect. The heater has been matter of study in open courses distributed in the Universidad Autonoma de la Ciudad de Mexico (UACM) oriented to that the participants construct their own system, in addition to its installation and tests. The obtained results have been excellent. The massive use of efficient solar receivers of self-construction can truly help to the decreasing of the gas discharges of greenhouse effect. [Spanish] En este trabajo se presenta un captador plano de auto construccion con relativamente bajo costo y facil manufactura, pero con un rendimiento termico superior a 40% para aplicaciones a temperatura menos de 60 grados centigrados que le permite satisfacer ...
The liquefaction reaction system of an NEDOL process coal liquefaction 1t/d PSU was opened and checked to investigate the cause of the rise of differential pressure between liquefaction reactors of the PSU. The liquefaction test at a coal concentration of 50 wt% using Tanito Harum coal was conducted, and it was found that the differential pressure between reactors was on the increase. By the two-phase flow pressure loss method, deposition thickness of deposit in pipelines was estimated at 4.4mm at the time of end operation, which agreed with a measuring value obtained from a {gamma} ray. The rise of differential pressure was caused by deposit formation in pipelines connecting reactors. The main component of the deposit is calcite (CaCO3 60-70%) and is the same as the usual one. It is also the same type as the deposit on the reactor wall. Ca in coal ash is concerned with this. To withdraw solid matters deposited in the reactor, there are installed pipelines for the ...
A home-made 3.1 kWh wind turbine that is promising to be the hottest new wind product to appear for home/farm users in some time, is described. The turbine is installed near a farm house in the high wind area of Mount Forest, Ontario. The turbine is hooked up to a four kilowatt Trace inverter charger which is coupled through a DC disconnect and C-60 charge controller to two sets of solar panels (seven panels of 120 W each by Solarex SX 120, and five panels by Sharp, each providing 1600 watt of solar power). The wind turbine and the solar panels, assisted by two 65-year old refurbished wind turbines, one bank of Gel Cell batteries, and an Onan 5 kW gas generator supply the electrical requirements of a seven member family in a 3400 square foot house. The new turbine is mounted on an 80-foot tower, has three eight foot Kevlar blades that produce a 17 foot overall sweep. The turbine weighs 615 lbs., produces 3.1 kW of pure power at just 310 rpms at ...
Experimental studies on the heat transfer and fluid dynamics of a high heat flux fuel rod for a very high temperature reactor (VHTR) were performed using a single channel test rig of a fuel stack test section (T{sub 1-s}) installed in a helium engineering demonstration loop (HENDEL). The fuel rod has been developed in order to enhance the turbulent heat transfer coefficient than that of the standard fuel rod obtained by the previous experiment. Two-dimensional square ribs were settled on the outer surface of the fuel rod axially to improve the heat transfer. The configuration of a square rib is 0.5 mm in width(w), 0.5 mm in height(h) and 5 mm in pitch(p): p/h=10. The experiment were carried out under the helium gas conditions of high temperature and pressure simulated the VHTR operation. For the turbulent region of Reynolds number 2,500{approx}8,000 of the VHTR core flow condition, it was found that the heat transfer coefficient of the fuel rod ...
Experimental studies on the heat transfer and fluid dynamics of a high heat flux fuel rod for a very high temperature reactor (VHTR) were performed using a single channel test rig of a fuel stack test section (T_1_-_s) installed in a helium engineering demonstration loop (HENDEL). The fuel rod has been developed in order to enhance the turbulent heat transfer coefficient than that of the standard fuel rod obtained by the previous experiment. Two-dimensional square ribs were settled on the outer surface of the fuel rod axially to improve the heat transfer. The configuration of a square rib is 0.5 mm in width(w), 0.5 mm in height(h) and 5 mm in pitch(p): p/h=10. The experiment were carried out under the helium gas conditions of high temperature and pressure simulated the VHTR operation. For the turbulent region of Reynolds number 2,500#approx#8,000 of the VHTR core flow condition, it was found that the heat transfer coefficient of the fuel rod ...
A study of advancements in power plant designs for use at geothermal resources in the low to moderate (300 to 400F) temperature range is reported. In 3 case studies, the benefits of R and D to achieve these advancements are evaluated in terms of expected increases in installed geothermal generating capacity over the next 2 decades. A parametric sensitivity study is discussed which analyzes differential power development for combinations of power plant efficiency and capitol cost. Affordable tradeoffs between plant performance and capital costs are illustrated. The independent review and analysis of the expected costs of construction, operation and maintenance of the Heber Binary Cycle Geothermal Power Demonstration Plant are described. Included in this assessment is an analysis of each of the major cost components of the project, including (1) construction cost, (2) well field development costs, (3) fluid purchase costs, and (4) well field and power plant operation ...
Radiation sterilization has several merits that it is a positively effective sterilization method, it can be used to sterilize low heat-resistant containers and high gas barrier films, and there is no possibility of residual chemicals being left in the packages. It has been commercially used in 'Bag in a Box' and some food containers. The #gamma# ray and an electron beam are commonly used in radiation sterilization. The #gamma# ray can sterilize large size containers and containers with complex shapes or sealed containers due to its strong transmission capability. However, since the equipment tends to be large and expensive, it is generally used in off production lines. On the other hand, it is possible to install and electron beam system on food production lines since the food can be processed in a short time due to its high beam coefficient and its ease of maintenance, even though an electron beam has limited usage such as sterilizing ...
The core bypass flow in a prismatic very high temperature reactor (VHTR) is an important design consideration and can have considerable impact on the condition of reactor core internals including fuels. The interstitial gaps are an inherent presence in the reactor core because of tolerances in manufacturing the blocks and the inexact nature of their installation. Furthermore, the geometry of the graphite blocks changes over the lifetime of the reactor because of thermal expansion and irradiation damage. The occurrence of hot spots in the core and lower plenum and hot streaking in the lower plenum (regions of very hot gas flow) are affected by bypass flow. In the present study, three-dimensional computational fluid dynamic (CFD) calculations of a typical prismatic VHTR are conducted to better understand bypass flow phenomena and establish an evaluation method for the reactor core using the commercial CFD code FLUENT. Parametric calculations ...
A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were investigated in detail. Furthermore, the design conception and basic performance of the pilot plant regarding pollution control and corrosion prevention were determined, based ...
Washboard (WB) modes (Smeulders P et al 1999 Plasma Phys. Control. Fusion 41 1303) are a very common edge instability regularly observed in the H-mode regime in JET. They are detected as (normally several) bands of continuously fluctuating magnetic activity rotating in the direction of the electron diamagnetic drift with typical frequencies in the range of 10-90 kHz. The time evolution of the WB mode frequency is found to follow qualitatively the evolution of the electron temperature measured near the pedestal top, probably due to the strong diamagnetic drift associated with the large pedestal gradients. Evidence for their involvement in the pedestal and ELM dynamics will be presented. Increasing WB mode amplitude is correlated with an increase in the time between consecutive type-I ELMs. In situations in which a sudden increase (decrease) of WB mode activity is observed, the build-up of the pedestal temperature (and, linked to this, also of the pedestal pressure) ...
An overview is presented of the US heating and space conditioning market, with specific emphasis on the type of fuel used. The author highlights he drive of electric utilities to increase their penetration in the space heating markets, and showed how geothermal heat pumps (GHPs) were recognized by utilities as an electrotechnology for all seasons; beneficial for customers, electric utilities and the environment. Then he focused on the utility driven National Earth Comfort Program (officially Geothermal Heat Pump Technology Demonstration and Market Mobilization Program) is a collaborative effort with the US Department of Energy and other public and private sector organizations. It will be implemented by the Geothermal Heat Pump Consortium, Inc. (GHPC), and is designed for the utility industry`s Climate Challenge under the President`s Climate Change Action Plan. The program has a budget of 100 million US$ until the year 2000. Program goals include: reduce annual greenhouse ...
Vacuum glazing consists of an evacuated space between two sheets of glass. Vacuum glazing has a large effect on energy savings in houses and buildings. Vacuum glazing can achieve higher insulating performance than conventional insulated glazing. Nippon Sheet Glass has successfully developed conventional vacuum glazing. In this study we investigated an advanced form of vacuum glazing. Its thermal insulation ability is equivalent to 100 mm thick glass wool thermal insulation. This vacuum glazing contained a SnO_2:F low emissivity surface. The influence of the residual gas in a vacuum space on heat flow is important to performance. For long-term thermal stability, it is very important to maintain vacuum stability. To understand this better, we studied the behavior of outgassing from the inside glass surfaces exposed to an external energy source. We have studied the behavior of outgassing from a glass surface using a Nd:YAG laser (operated at 355 ...
This publication describes the modification of the road traffic exhaust emission calculation model LIISA and presents the new calculation results. The model has already established its position as the most important inventory tool for regional road traffic emissions in Finland. The LIISA model calculates road traffic emissions as a whole. The system comprises of three separate models: 1. a model for calculating automobile emissions for the years 2001-2021, 2. a model for calculating emissions backwards for the years 1980-2000, 3. a model for calculating the emissions of motorcycles and mopeds. All three parts have been modified. The LIISA model is one of the submodels of the comprehensive LIPASTO calculation system developed at VTT Building and Transport. The LIPASTO model is an inventory tool for emissions regarding all traffic modes in Finland. The LIPASTO with its submodels will be updated yearly with new mileage and vehicle data. The models itself and their ...
In August 1989, representatives from the Alberta Oil Sands Technology and Research Authority (AOSTRA) were the guests of the USSR Interbranch Scientific Technological Complex, Oil Recovery Institute (MNTK) in an extensive visit to heavy oil and gas fields and to various research institutes. Observations made during this tour concerning developments in the USSR heavy oil/bitumen industry, enhanced oil recovery, research programs, proposals for joint ventures, and technological developments are reported. It is noted that oil production in the USSR seems to have peaked and is in a state of decline, indicating the vital importance of enhanced recovery projects in reversing this trend. The areas visited included the Yarega field, where underground thermal recovery methods are used; the Sakhalin Island area, where successful thermal methods are used and where the USSR's largest offshore drilling rig is located; the Krasnodar/Black Sea area, where MNTK's ...
Nowadays there is a lot of welding processes giving an answer to the great diversity of joints to realize and to the characteristics of the metals employed. The first chapter describes the different power sources used in welding. After that, a more detailed explanation of arc welding is given. Finally we present the design of a welding test bed. One can, of course, use an empirical approach to optimize a process. Nevertheless there are advantages in choosing an analytical approach since we can expect significant progress in the understanding of the dynamical interactions in the arc. That's why we present in the second chapter the theoretical knowledge concerning the behaviour of the molten metal transferred during Gas Metal Arc Welding. This work involves as well an experimental aspect required for the elaboration of the databases used to build the model. The recordings were made at CTAS on a test bed equipped with an acquisition ...
This paper presents efforts to date and prospective goals towards development of a modelling and analysis framework which is comprehensive enough to address the global climate crisis, and detailed enough to provide policymakers with concrete targets and achievable outcomes. In terms of energy efficiency policy, this requires coverage of the entire world, with emphasis on countries and regions with large and/or rapidly growing energy-related emissions, and analysis at the 'technology' level-building end use, transport mode or industrial process. These elements have not been fully addressed by existing modelling efforts, which usually take either a top-down approach, or concentrate on a few fully industrialized countries where energy demand is well-understood. Inclusion of details such as appliance ownership rates, use patterns and efficiency levels throughout the world allows for a deeper understanding of the demand for energy today and, more ...
The objective of this paper is to present a theoretical evaluation of soil and house related factors that may affect the transport of radon from the soil into houses. A two-dimensional mathematical model was used to simulate the diffusive and convective transport of radon into the house through idealized openings in the understructure. With the help of model predictions we tried to find out whether diffusion or convection predominates and under which circumstances. Radon transport through cracks in the house understructure is influenced mainly by the soil permeability, radon concentration at the soil-crack interface, the total area of cracks and the pressure difference across cracks. Because of its large range of variability, the soil permeability appears to have the greatest effect on the radon transport through cracks. At permeabilities below 1x10"-"1"2 m"2 diffusive transport predominates and is almost invariable with the soil permeability. For permeabilities between 1x10"-"1"2 m"2 ...
The Early Palaeozoic Warburton Basin underlies the gas and oil producing Cooper and Eromanga Basins. Postdepositional tectonism created high potential fracture porosities, complicating the stratigraphy and making reservoir prediction difficult. Sequence stratigraphy integrating core, cuttings, well-log, seismic and biostratigraphic data has recognized a carbonate-dominated to mixed carbonate/siliciclastic supersequence comprising several depositional sequences. Biostratigraphy based on trilobites and conodonts ensures reliable well and seismic correlations across structurally complex areas. Lithofacies interpretation indicates sedimentary environments ranging from carbonate inner shelf, peritidal, shelf edge, deep outer shelf and slope to basin. Log facies show gradually upward shallowing trends or abrupt changes indicating possible sequence boundaries. With essential depositional models and sequence analysis from well data, seismic facies suggest general ...
Full text: In heavy-water-moderated power reactors, tritium is primarily produced by neutron capture in deuterium nuclei in the moderator and coolant. For CANDU 6 reactors, the estimated steady-state values are #approx# 3 TBq#centre dot#kg"-"1 D_2O in the moderator and #approx# 74 GBq#centre dot#kg"-"1 D_2O in the coolant. Tritium removal is one option available to reactor operators for use in their heavy water and tritium management strategies. The WTRF is designed to remove tritium from tritiated heavy water in each of the four CANDU units at the Wolsung Site, to immobilize the tritium and to store it on site. The detritiation process is based on three steps: the first one (front-end) involves the transfer of tritium from heavy water to deuterium gas; the second one (enrichment) concentrates the tritium in a cryogenic distillation system to produce essentially pure D_2 and T_2 streams; and in the third step the tritium is packaged for long-term storage. The WTRF ...
A gas diffusion semiconductor electrode and solar cell and a process for gaseous fixation, such as nitrogen photoreduction, CO/sub 2/ photoreduction and fuel gas photo-oxidation are described. The gas diffusion photosensitive electrode has a central electrolyte porous matrix with an activated semiconductor material on one side adapted to be in contact with an electrolyte and a hydrophobic gas diffusion region on the opposite side adapted to be in contact with a supply of molecular gas.
This thesis examines the costs and benefits of energy management in office buildings and investigates the relationships between operating costs, space lease contracts, and building value. Energy management be building owners and managers begins with monitoring and analysing building energy, use and continues by reducing energy consumption through operating procedure changes, equipment replacement and control personnel training and continued monitoring. The cost to complete energy management projects in 12 British Columbia office buildings is analyzed. The average before-tax internal rate of return for the 12 energy management programs was 22.1% on total expenditures of Canadian $1.2 million. Nine of the buildings are owned and occupied by the provincial government, and the return on investment directly benefits the public. However, in the three prvately owned ...
PEFP(Proton Engineering Frontier Project) is developing beamlines for various application fields by using the high current 100MeV proton linear accelerator. Beamlines were characterized and categorized by the beam energy, average currents, and irradiation conditions. Among these beamlines the TR104 is designed for the basic science and the research of the aerospace. Before the construction and installation of beamlines, we try to practice and prepare the detail process of installation by the precedent study of TR104 beamline in KAERI site. By this work installation process was checked and confirmed for the same condition of the PEFP site
The book tries about the International and national aspects, natural gas situation, production, consumption, prices, demand projection, energetic plans, norms and laws of the natural gas in Colombia
This document provides information on the supply and disposition of natural gas to a wide audience. The 1996 data are presented in a sequence that follows natural gas from it`s production to it`s end use.
The installation and performance of a water source heat pump in Minnesota are discussed. The operating cost was found to be higher than expected. (MHR)
This invention pertains to a light weight underground pipe or cable installing device adapted for use in a narrow and deep operating trench. More particularly this underground pipe installing device employs a pair of laterally movable gates positioned adjacent the bottom of the operating trench where the earth is more solid to securely clamp the device in the operating trench to enable it to withstand the forces exerted as the actuating rod is forced through the earth from the so-called operating trench to the target trench. To accommodate the laterally movable gates positioned adjacent the bottom of the narrow pipe installing device, a pair of top operated double-acting rod clamping jaws, operated by a hydraulic cylinder positioned above the actuating rod are employed.
... A second hydrometeor sampler (MRI Model 1220 ... The cloud particle probe normally installed in ... to the northeast showed no significant movement. ...
The optimization of the safety characteristics of electrical installations in industrial plants with explosion or fire hazards can be obtained only through a careful interdisciplinary study and analysis carried out at the onset of the plant project design phase. The least complex and costly and safest solutions are those which are born from plant designs which take into account the typology of the industrial process or technology, or which incorporate pollution abatement measures and adequate safety measures for the electrical installations. This paper provides examples to illustrate how the global plant economy is fundamentally dependant upon a multi-disciplinary initial effort in design analyses. Comments are made relevant to the adequacy of the safety requirements established by existing and planned Italian norms in dealing with safety and fire protection for high-tech industrial plant electrical installations.
A high-average power (kW) infrared (IR) free-electron laser (FEL) is currently being commissioned for the Jefferson Laboratory FEL User Facility. The IR FEL is driven by a unique superconducting rf linac which is recirculated to recover electron beam power that is not radiated in the FEL. The design and installation of the vacuum system for the FEL involved particular attention to minimizing particulate contamination which could cause problems with the superconducting acceleration cavities and the high power FEL optics. Particulate contamination levels of all vacuum components were monitored during the cleaning process using laser scattering. Cleaning, transport, and installation procedures were developed to minimize the contamination of the complete system. We will summarize a data base we compiled of particulate contamination levels of the various components installed in the FEL vacuum system.
...been a world leader in the design, manufacture and installation of high quality precision-engineered systems for water and wastewater treatment fo Create Free Account ...
...been a world leader in the design, manufacture and installation of high quality precision-engineered systems for water and wastewater treatment fo Bulletins Environmental Expert ...
2011 Department of Energy Investments in Carbon Capture Technologies 2010 Smart Meter Installations DOE Recovery Field Projects and State Memos Advanced Vehicle...
The deliveration by the Nuclear Safety Commission was commenced on the alteration in reactor installation, as it had been inquired by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc. (J.P.N.).
The deliberation by the Nuclear Safety Commission was initiated on the alteration in reactor installation, as was required by the Ministry of International Trade and Industry. The alteration is the additional installation of the reactor No. 2 in the Sendai Nuclear Power Station, Kyushu Electric Power Co., Inc. It is a PWR power plant with thermal output of about 2,660 MW (electric output of 890 MW), to be installed, adjoining to the reactor No. 1 of the same type and capacity under construction. In the examination by MITI, it was confirmed that the technological capabilities for its construction and operation and the radiation protection measures in power generation are both sufficient. The contents of the examination include the siting conditions, the location and construction of reactor facilities, etc.
Eight units (low-power model Z-12's) were purchased, all for installation at continuously- operating stations in the Los Angeles prototype Dense GPS ...
The origin of natural gas in the Japanese oil and gas fields are geochemically studied. Samples are taken from structural natural gas, surface gas seepage, water-dissolved natural gas and coal-field gas of the Japan Sea coast area. The origins of primary hydrocarbons are classified into bacteria gas and thermogenic gas, the latter being subclassified into gas in oil production zone with the per million deviation of the carbon isotope (/sup 13/C/sup 1/) of methane less than -35 and those gases with maturity higher than this. Surface gas seepage is subjected to migration and bacterial oxidation. Coal gas is similar to oil gas. The CO/sub 2/ concentration is 0 - 2% and /sup 13/CO/sub 2/ deviations from -30 - +30. The origin can be barely ...
This final report for the Swiss Federal Office of Energy (SFOE) is one of a series of reports concerning municipal development in various cities in Switzerland. The four city districts involved include Basel (Gundeldinger Feld), Lausanne (Bellevaux), Lucerne (Basel-/Bernstrasse) and Zurich (Werdwies). This paper takes a look at aspects of building ecology. In the four areas, the following building types and projects were examined with respect to their ecology: Basel: conversion of commercial premises to a community centre, Lausanne and Lucerne: Enhancement of residential areas, Zurich: a new residential building. Criteria examined include general building ecology, building materials, raw materials, toxic substances, recycling, maintenance and deconstruction, energy for heating and hot water, grey energy, electricity, ground usage, water, wastes and public infrastructure. Knowledge ...
Full text. This research assesses models for new nuclear build in European Union (EU) member states to find the most stable form. The countries examined in this study are the United Kingdom and Romania. The results attest that due to various historical, political, competition, and electricity market structural conditions Romania and the United Kingdom have emerged with different models for new build nuclear projects. This paper begins with an assessment of the effects on the nuclear sector from energy, environmental and competition legislation in the EU. Then the political and economic climate of the aforementioned EU member states is completed. Following this an overview of the market structure of the electricity sector in those respective countries is conducted. Then the key research on the models and the phases of new nuclear build are explored. The research concludes each model has transcended from different political ...
The new guidelines for indoor air hygiene in school buildings are intended as a response to current requirements in school practice. The recommendations aim to help to avoid mistakes in modernising school buildings and to provide hygiene-specific support in planning of new school buildings. The guidelines are laid out as follows: (a) In the general section the targets of the guidelines and the target groups are addressed. The current indoor hygiene situation in German schools is described, followed by the parameters with regard to peripheral issues which will not be dealt with further; (b) Part A deals with the hygiene requirements in the practical running of schools. Besides general requirements for maintenance and operation the important issues of cleaning and ventilation are considered, as well as minor building works; (c) Part B provides an overview of important chemical and biological contaminants ...
In this paper, the authors describe the characteristics of design seismic input motions and recently observed seismic records of base isolated buildings in Japan. First, we describe some seismic design spectra for building structures which were adopted. Then we show response spectra and energy spectra of observed records obtained during two recent major earthquakes (The 1995 Hyogo-ken Nanbu Earthquake and the 2003 Tokachi-oki Earthquake), which demonstrate the effectiveness of base isolation against large amplitude earthquake ground motion. We also introduce the responses of base isolated buildings during some earthquakes including the Tokachi-oki Earthquake. These data were gathered through questionnaires sent to many engineers who had conducted response observations of base isolated buildings. Last, an example of a base isolated building on soft ground is shown. We point out the ...
A study was conducted to predict indoor ventilation, smoke movement and fire propagation in a new building currently under construction at the Ecole Polytechnique de Montreal. It was conducted in response to concerns regarding the impact that air quality, in normal operation conditions, and smoke concentration, in the event of a fire, may have on occupants of a building. A detailed three-dimensional model of the new building was constructed using the NURBS-based modeler, Rhino. Simulations of fire propagation and airflow ventilation were performed in different areas of the building. The flow pattern data was analyzed using the computational fluid dynamics (CFD) program called FLUENT. It predicted air flow conditions and estimated the mean age of air (MAA) in the room. Real-world geometries, such as diffuser inlets, have a significant impact on overall fluid flow behaviour and are necessary for this type ...
The behaviour of the packaging materials under radiation field has a great importance in radiation processing, because, in most cases, they are finally responsible for the preservation of the beneficent changes achieved in irradiated products. For example, in radiation sterilisation and food irradiation, the packages must preserve the sterilisation, respectively the sanitisation. They must preserve also the physical barrier feature. The radiation effects on plastics were extensively studied in the last decades for nuclear industry and more recently for radiation processing. The two major effects of nuclear radiation on polymeric materials are the degradation and cross-linking. The degradation consists in breaking of macromolecules after interaction with nuclear particles, amplified by the free radicals which persist long periods, especially in crystalline polymers. Oxygen could penetrate the sample and interact with free radicals so that the degradation process continues after the ...
When completed, Lawrence Livermore National Laboratory's (LLNL) National Ignition Facility (NIF) will be the world's largest laser with experimental capabilities applicable to stockpile stewardship, energy research, science and astrophysics. As construction of the conventional facilities nears completion, operations supporting the installation of specialized laser equipment have come online. Playing a critical role in the precision cleaning of mechanical parts from the NIF beamline are three pieces of aqueous cleaning equipment. Housed in the Optics Assembly Building (OAB), adjacent to NIF's laser bay, are the large mechanical parts gross cleaner (LMPGC), the large mechanical parts precision cleaner (LMPPC), and the small mechanical parts gross and precision cleaner (SMPGPC). These aqueous units, designed and built by Sonic Systems, Inc., of Newtown, Pennsylvania, not only accommodate parts that vary greatly in size, ...
A.C.R.O. (Association pour le Controle de la Radioactivite dans l Ouest) is a French non governmental organisation that operates a laboratory for radioactivity analysis. It was created in 1986 as a response to people demands for information and reliable, independent testing. The organisation mainly carries out missions of information and training for its correspondents and more generally for a wide audience, particularly for people who worry about problems of environment, health, management of radioactive waste and emissions. Thanks to its structure, it enables citizens to involve themselves together with scientists so as to gain access to information that was hither to reserved to specialists. The organisation can vouchsafe its independence from the diversity of its members and volunteers, as well as from the diversity of its money resources. Besides its headquarters situated on the city of Caen area (Normandy), three branches situated in North Normandy, in Touraine and North Cotentin ...
Forced vibration experiment has been conducted for the reactor building of Sendai Unit 1 nuclear power plant. The beam vibrational behaviors of the outer shielding building and the internal concrete structure have been observed by using a 50 tf vibration for low frequency region, and a 10 tf vibration for high frequency region, respectively. The outline of the experimental methods, the data handling system and the major results of experiment are described. The experimental results were simulated by an analytical model. The proper vibrational frequency and the vibration modes obtained by the analysis were compared with those obtained by the experiment. By these comparisons, the adequacy of the analytical method employed for the design was confirmed.
This Addendum to the Facility Safety Plan (FSP) 360 Complex describes the safety requirements for the safe conduct of all biohazardous research operations in all buildings within the 360 complex program areas. These requirements include all the responsibilities and authorities of building personnel, operational hazards, and environmental concerns and their controls. In addition, this Addendum prescribes facility-specific training requirements and emergency controls, as well as maintenance and quality assurance requirements for ES&H-related building systems.
This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.
This document provides guidance for modeling and inspecting energy-efficient property in commercial buildings for certification of the energy and power cost savings related to Section 179D of the Internal Revenue Code enacted in Section 1331 of the 2005 Energy Policy Act and noted in Internal Revenue Service Notice 2006-52. Specifically, Section 179D provides federal tax deductions for energy-efficient property related to a commercial building's envelope; interior lighting; heating, ventilating, and air conditioning; and service hot water systems.
This conference is composed of 21 communications and 21 posters in the domain of building ventilation and indoor air quality; the main themes are: indoor air quality assessment and optimization; performance enhancement and optimization of ventilation systems and equipment; ventilation systems for renovated and rehabilitated buildings; French and European regulations, standardizations and certifications; experimental and numerical simulation studies concerning ventilation systems, air flow, temperature distribution, air quality, thermal comfort and ventilation-induced acoustic levels
It is important to accurately estimate the effects of strong earthquake motions on the basemat uplift behavior and structural responses for the seismic design of nuclear power plant buildings. In this paper, an analysis model which describes the soil part using the 3 dimensional FEM was proposed to be used when the ground contact ratio is low, and the validity of this model was confirmed. Furthermore, investigations using the model were carried out where the attaching force under the basemat was taken into account, in order to more realistically estimate the basemat uplift behavior. The effects in the case of the building being embedded were also investigated.
It is important to accurately estimate the effects of strong earthquake motions on the basemat uplift behavior and structural responses for the seismic design of nuclear power plant buildings. In this paper, an analysis model which describes the soil part using the 3 dimensional FEM was proposed to be used when the ground contact ratio is low, and the validity of this model was confirmed. Furthermore, investigations using the model were carried out where the attaching force under the basemat was taken into account, in order to more realistically estimate the basemat uplift behavior. The effects in the case of the building being embedded were also investigated.
Many older homes are equipped with mercury-containing gas regulators that reduce the pressure of natural gas in the mains to the low pressure used in home gas piping. Removal of these regulators can...Full Text Available
There are no 'intelligent' buildings but only 'intelligently controlled' buildings. Intelligent control requires communication between technical facilities, which in turn requires building automation and system integration. [German] Es gibt keine ''intelligenten'', sondern nur ''intelligent betriebene'' Gebaeude. Mit dieser Feststellung ist die Vorbedingung festgelegt, dass Gebaeude ein gewerkeuebergreifendes System benoetigen, das die Komponenten miteinander kommunizieren laesst. Dafuer eignet sich die Gebaeudeautomation. Damit diese ihre Aufgaben erfuellen kann, bedarf es der Systemintegration. (orig.)
Background:To encourage evidence-based practice, an Annals of Internal Medicine editorial called for a new professional on clinical teams: an informationist trained...Full Text Available
The Army Reactor Area (ARA) II was constructed in the late 1950s as a test site for the Stationary Low Power Reactor No. 1 (SL-1). The SL-1 was a prototype power and heat source developed for use at remote military bases using a direct cycle, boiling water, natural circulation reactor designed to operate at a thermal power of 3,000 kW. The ARA II compound encompassed 3 acres and was comprised of (a) the SL-1 Reactor Building, (b) eight support facilities, (c) 50,000-gallon raw water storage tank, (d) electrical substation, (e) aboveground 1,400-gallon heating oil tank, (f) underground 1,000-gallon hazardous waste storage tank, and (g) belowground power, sewer, and water systems. The reactor building was a cylindrical, aboveground facility, 39 ft in diameter and 48 ft high. The lower portion of the building contained the reactor pressure vessel surrounded by gravel shielding. Above the pressure vessel, in the center portion ...
This program deals with solid waste disposal with topics/services covering: Reusable Building Materials and Large Household Items Exchange, Beneficial Use Determination, Biosolids, Certification, Compost Facil...
This paper describes the results of a French-Lebanese scientific cooperation, between 2001 and 2005, about 'Rational use of energy in the residential buildings in Lebanon and adaptation of an energy certification procedure'. The aim of this project is to promote the energy efficiency in the existing residential buildings in Lebanon, using an energy certification procedure, and to evaluate the energy certification foresight with prospective methods. The paper first describes an energy investigation in Lebanese residential buildings, and the energy certification procedure. It presents the foresight methodology implemented to identify the key variables and the actors. Finally, the paper exposes the morphological method which allows to elaborate three scenarios of energy performance certification. These scenarios are presented in order to provide a decision making for the actors of the Lebanese energy policy.
... Those functions are fundamental routines to build a power model for more complex circuits or functional blocks. ... 21 of 54 6. Memory Power Model ...
A brief article considers the possible result of the enquiry into Nirex`s plan to build an underground rock laboratory at Sellafield in relation to radioactive waste disposal in the UK. (UK).
Apr 21, 2011 ... The system of lipid peroxidation reacts regularly to adverse effects and results in enhancement of lipid peroxidation and build-up of LPO ...
For an air conditioned building, the major electricity consumption is by the heating, and air conditioning (HVAC) system. As energy saving strategies may be in conflict with the criteria of indoor air quality and thermal comfort, a concept of the building environmental performance model (BEPM) has been developed to optimize energy consumption in HVAC systems without any deterioration of the indoor air quality and thermal comfort. The BEPM is divided into two main modules: the adaptive comfort temperature (ACT) module and the new demand control ventilation (nDCV) module. This study aims to enhance and prompt the conventional operation of the air side systems by incorporating temperature reset with the adaptive comfort temperature control and the new demand control ventilation system in high rise buildings in Hong Kong. A new example weather year (1991) was established as a reference to compute the energy use of HVAC systems ...
The activities and the policy in the Netherlands regarding the development of the title systems since 1990 are briefly outlined, focusing on the use of PV-systems in buildings. 5 figs., 1 tab.
Capturing the Daylight Dividend conducted activities to build market demand for daylight as a means of improving indoor environmental quality, overcoming technological barriers to effective daylighting, and informing and assisting state and regional market transformation and resource acquisition program implementation efforts. The program clarified the benefits of daylight by examining whole building systems energy interactions between windows, lighting, heating, and air conditioning in daylit buildings, and daylighting's effect on the human circadian system and productivity. The project undertook work to advance photosensors, dimming systems, and ballasts, and provided technical training in specifying and operating daylighting controls in buildings. Future daylighting work is recommended in metric development, technology development, testing, training, education, and outreach.
Apicomplexans are pathogens responsible for malaria, toxoplasmosis, and crytposporidiosis in humans, and a wide range of livestock diseases. These unicellular eukaryotes are stealthy invaders, sheltering...Full Text Available
The overall aim is to develope programme modules for a Danish integrated computer system for projecting buildings and to ensure that Danish programmes are compatible with international systems. The programmes to be integrated here were AutoCAD and SCRIBE-Models and the simulation programme tsbi3 for the calculation of indoor climate conditions, power demand and energy consumption in buildings. For the calculation of humidity and temperature conditions in constructions a certain amount of integration is carried out with the MATCH programme (Moisture And Temperature calculations for Constructions of Hygroscopic materials). The activities embodied in the pilot projects are described in this working report in addition to individual computer programmes and prototypes, and examples and diagrams are presented. The programmes described deal with handling design elements in relation to AutoCAD designs, and the formatting of a ...
The widespread use of building materials with relatively high radium concentrations may increase population exposure. A method is presented for measuring effective diffusion coefficients and exhalation rates of radon from such materials. Equations for use in the experimental determination of these values are obtained theoretically. The experimental set-up consists of a container which is hermetically sealed to a slab of the building material. Nitrogen is blown through the container and then through an ionization chamber which is connected to an electrometer and X-Y plotter, and the radon concentration is measured continuously. Exhalation rates of radon from some major building materials measured by this method will be used as reference levels. The method can also be used to determine other properties such as porosity. (author).
Buildings Energy-Efficient Research Laboratories Energy Efficiency in Federal Facilities Energy Efficiency Standards Group Energy Efficient Windows Collaborative Energy &...
Sewage gas or biogas as a product of anaerobic digestion contains methane and carbon dioxide as its main components. Biogas is scrubbed off carbon dioxide in absorption columns and purified to natural-gas quality. The purified gas then is piped to the gas pressure control station and fed into the public network. Description of process and plant is given.
The effect of atmospheric radioactive emissions from United Kingdom nuclear installations on acid deposition is assessed. Nitrogen oxide and ozone production resulting from and associated with discharges of airborne radioactivity, comparison with conventional emissions, and the direct effects of radioactive emissions on trees, are all discussed. (UK).
A solar unit is described which contains a cavity radiation receiver, parabolic-cylindrical concentrator, and reflector arranged between the radiation receiver and the concentrator symmetrically in relation to the optical plane of the latter. In order to expand the range of use, it contains a pair of flat mirrors with 2 working surfaces installed at an angle and symmetrically to the optical plane of the parabolic cylindrical concentrator between them and the reflector, while the latter is made in the form of 2 flat mirrors installed at an angle on the cavity radiation receiver.
A slurry intake device is proposed which contains an inlet sleeve, housing with grating installed with the discharge end in the zone of the slurry outlet, and hinged deflector. In order to conserve the clay mud, it is equipped with a tie rod and two-arm lever which is kinematically linked to the deflector and the grating. It is installed by hinges in relation to the housing and the latter is attached by hinges to the inlet sleeve. The deflector is arranged in the zone of slurry outlet. The device is distinguished by the fact that the deflector is equipped with a cantilever on which a fixable weight is attached.
Nexans has developed a new type of high voltage sea cable with metal barrier for dynamic application, suited for floating installations such as vessels, floating wind turbines or floating platforms. A brief presentation of the cable's design (ml)
This book brings recommendations and information on the choice and the operating of heating systems and domestic hot water production in order to better choose the house, to better use the heating and to preserve the environment. General notions on the different heating systems and their operating on the renewable energies used and the heating emitters offer advices for the purchase of a house. (A.L.B.)
A possibility of short-lived isotopes production in inter-tank section between the first and the second drift tube tanks (20.45 MeV) in INR linac is considered. At the initial stage the main efforts are concentrated on production of fluorine-18 used for positron emission tomography. The results of beam forming calculations, target heating calculations, equipment activation calculations as well as installation configuration and design are presented.
The focus of general public concern on the environment results in the use of underground lines being considered since they offer alternative or interesting complementary solutions for the bulk transmission of electrical energy. This leads to the installation of underground cables in some areas, where overhead lines would automatically have been considered in the past.
A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.
Application, design, and installation of the cable line in steel pipe with oil under pressure for 500 kV is considered. The cable construction and design specifications are presented. Manpower requirements for the installation of the cable, extending from the hydrogenerators to the outdoor switchgears or to the change point where they are connected to overhead power lines, are discussed and data provided.
A string sieve is proposed which includes a frame, a sifting surface made of string, a device for attaching the strings made in the form of rollers installed in staggered order and a tensing device attached to traverses. To improve the effectiveness of sifting by self cleaning of the sifting surface during operation, the rollers are installed on the traverses by means of a unit of hinges, whose elastic elements are made with varying rigidity.
A model designed to evaluate the cost-effectiveness of the use of robotics and remote tooling in achieving reduction of occupational exposure at nuclear installations is presented. The operational cost saving of implementing dose reduction action is introduced as a key parameter. Through specific example, a partial demonstration of the model is given. (author).
Installation of the electrical equipment at the Barstow Solar Pilot Plant is the concern of this construction package. Technical specifications for power and instrument cables, meteorological instruments, and control cables are defined. The documentation requirements are briefly discussed.
We report the performance of a micro gas turbine on biomass producer gas and mixtures of biomass producer gas with natural gas. The micro gas turbine delivers full power on gas mixtures with a heating value of at least 15 MJ/Nm{sup 3}. For gas of lower heating value, the maximum fuel gas flow limits the attainable power. The lower limit for stable operation is about 8 MJ/Nm{sup 3}. The gross efficiency of the micro gas turbine depends on output power but not on the gas heating value, within our measurement accuracy. Above 70% of full power, emissions of CO and NO are 40 and 10 times lower than those of a gas engine of similar size. At part load below 70% of full power, the micro gas turbine burner switches to a different operating mode ...
This Health and Safety (HSE) document offers technical information on the design of foundations for supports in offshore installations, and relates particularly to the North Sea. It is based largely on guidance offered earlier in Section 20 of the Fourth Edition of the Health and Safety Executive's 'Offshore Installations; Guidance on Design, Construction and Certification', which was withdrawn in 1998. The document contains a general section on foundations and the rest of the document comprises sections on: (a) piled foundations (planning, problems, pile make-up, steel stresses, design of pile foundations, axial pile capacity, factors of safety for piled foundations, load-deflection of piles, and piles for tethered buoyant structures); (b) foundations for gravity structures (foundation types, loads and reactions during installation, operating loads and reactions, foundation problems, cyclic load ...
The paper gives an overview on the technologies and applications of automatic wood furnaces. The combustion systems are defined by the flow condition: With increasing gas velocity, fixed bed, stationary fluidized bed (SFB), circulating fluidized bed (CFB), and entrained flow reactors are distinguished. The furnace design and typical applications are described. Further, a comparison is presented which gives data of the typical size range and fuel types for the different combustion systems. The most common fixed bed reactors are under-stoker and grate furnaces. While under-stoker furnaces are applied in the size range from 20 kW to 2.5 MW, grate furnaces cover the size range from a few 100 kW up to more than 50 MW. Under-stoker furnaces are well suited for wood fuel with low ash content, moderate water content and limited fuel size. Grate furnaces are also suited for fuel with high ash and water content and large fuel sizes. Hence grate furnaces are nowadays most ...
The most effective way to generate electricity out of biomass is the gasification and the use of the gas in a gas engine. The conversion of the organic carbon with the gasification of biomass is higher than 95 %. Depending on the gasification concept, the efficiency of gasifiers is found between 70 and 90 %. If the pyrolysis gas is used in a gas engine, an electric efficiency of about 26 % referring to the primary amount of energy can be obtained. With efficient gas cleaning (cleaning for tar and dust), pyrolysis gas is well qualified for engine combustion. Through modern state of engine controlling there are ways to have complete control of the fluctuations in the gas composition. Furthermore, the minor calorific value of offered wood gas poses no problem for turbo charged lean-burn gas engines. ...
This patent describes an electrodeless lamp. It comprises: a microwave cavity; a source of microwaves in communication with the cavity; a lamp envelope containing a plasma-forming medium mounted within the microwave cavity; a gas manifold for feeding gas to at least one gas passageway for directing a stream of gas to the outer surface of the envelope; a gas leak passageway leading from the gas manifold; a conductive mesh assembly for retaining microwaves within the cavity and permitting light to be emitted from the cavity. The assembly including gas flow blocking means for preventing the flow of gas through the gas leak passageway when the screen is in place in the lamp; and means for shutting off the source of microwaves when the gas pressure in the manifold drops below a ...
The method and results are presented of measurements of the coefficients of "2"2"2Rn emanation from samples of fly- ashes and slag and other commonly used building materials. A chamber was used for electrostatic collection of "2"2"2Rn decay products. The coefficients of emanation ranged from 0.2% (fly- ashes) to 21.3% (phosphogipsum from phosphorit). (author).
Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)
This paper deals with the control of an electromechanical valves engine. The control uses neural networks in order to build a non-linear model of engine filing which depends on the driven inlets. The aim is to build this real-time model and to integrate this model to a control system which performs an iterative inversion. (J.S.)
Performance predictions have been made for attached-sunspace types of passively solar heated buildings. The predictions are based on hour-by-hour computer simulations using computer models developed in the framework of PASOLE, the Los Alamos Scientific Laboratory (LASL) passive solar energy simulation program. The models have been validated by detailed comparison with actual hourly temperature measurements taken in attached-sunspace test rooms at LASL.
Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.
Information technology plays an important role in medicine because of the advanced decision support systems (DSS) it can provide. We provide an overview of the building blocks necessary for a medical decision support system and introduce seven research articles in this special issue that describe the development and evaluation of individual medical DSS building blocks or complete medical DSS.
This case study illustrates how an existing building can be transformed into a sustainable, green facility through teamwork. This multi-purpose building comprises office space, combustion testing facilities, and microwave communications center. The paper discusses internal systems design, indoor air quality, commissioning, economics, operations and maintenance, and monitoring.
... Social Capital Social capital describes circumstances in which individuals and organisations can use membership in groups and networks to secure benefits. Connections within and between networks reinforce the belief that these social networks have a value and can be used as a platform for further social progress. In this light, natural capital and social capital are closely related, and policies that build or destroy one often build ...
The special geodetic problems encountered during the construction of the Paks nuclear power plants are treated. The main building with its hermetically connected components including the reactor, the steam generators, the circulation pumps etc. impose special requirements on the control net of datum points. The geodesy tasks solved during the construction of the main building are presented in details.
The primary purpose of the Rocky Flats Field Office of the US Department of Energy is to decommission the entire plant. In an effort to improve the basis and the accuracy of the future decommissioning cost, Rocky Flats has developed a powerful but easy-to-use tool to determine budget cost estimates to characterize, decontaminate, and demolish all its buildings. The parametric cost-estimating tool is called the Facilities Disposition Cost Model (FDCM).
Since many years, people take care of hazardous consequences of a non controlled economic growth and the sustainable development concept gains on one. This situation leads to consequences in the building industry and in the energy policy: buildings insulation in consideration, demand of consultants. In this framework, the partnership between Gaz De France and CICF has to be built. (A.L.B.)
This document deals with energy management in buildings. It presents the conditions for a good implementation of energy management. These conditions include the total involvement of the management and the training of the staff. The structure of this implementation is presented together with the tools for an efficient energy management. Eventually, information on air quality and comfort in buildings is provided, as well as the management of complaints linked to them. (TEC). 1 tab.
Geothermal heat pump systems necessitate a comprehensive approach to geology and building facilities in order to be energetically useful and efficient. Cooperation with geothermal experts should be sought at an early projecting stage in order to obtain reliable data. Geothermal data and the technical facilities of the building must be matched for the project to be both effective and efficient. (orig.)
The Fast Flux Test Facility (FFTF) bottom-loading transfer cask (BLTC) system is designed to provide ex-vessel fuel transfers of irradiated reactor components between the reactor containment building and the LMFBR shipping cask in the reactor service building. This system is being procured from National Lead Industries, Wilmington, Delaware, under management of Aerojet Manufacturing Company.