WorldWideScience
3

The new WHO classification of brain tumors. Radiological aspects of 4 new tumor entities; Die revidierte WHO-Klassifikation der Hirntumoren. Radiologische Aspekte unter besonderer Beruecksichtigung von vier neuen Tumorentitaeten  

Energy Technology Data Exchange (ETDEWEB)

Characterisation of the classification of brain tumours authorised by the WHO. Method of appraisal: This classification was revised and published in its second version. In the revision, some tumours were regrouped histogenetically and some tumour variants were added. Radiologically relevant changes of the classification include the differentiation of four new tumour entities that are easily distinguished by MR imaging. These four tumours belong to the group of childhood tumours or tumours occurring in early adulthood and are characterized by a good prognosis after extirpation. Results of appraisal: Central neurocytomas are small-cyst ventricular tumours associated with the foramen of Monroi and show moderate contrast enhancement. Infantile desmoplastic gangliogliomas/astrocytomas commonly consist of a solid tumour portion related to the leptomeninges with pronounced contrast enhancement and a typically very large cyst. Pleomorphic ...

1997-06-01

4

An Effective Method of Image Retrieval using Image Mining Techniques  

CERN Document Server

The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...

2010-01-01

5

Characteristics of common solid liver lesions and recommendations for diagnostic workup  

UK PubMed Central (United Kingdom)

Due to the widespread clinical use of imaging modalities such as ultrasonography, computed tomography and magnetic resonance imaging (MRI), previously unsuspected liver masses are increasingly being...Full Text Available

2009-07-14

6

Wake-Up Stroke: Clinical and Neuroimaging Characteristics  

UK PubMed Central (United Kingdom)

BackgroundApproximately 25% of ischemic stroke patients awaken with neurological deficits. In these patients, in whom the time from symptom onset is uncertain, brain imaging is a...Full Text Available

2010-03-01

7

Method for the reduction of image content redundancy in large image databases  

Energy Technology Data Exchange (ETDEWEB)

A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.

2010-03-02

8

Spectral characteristics of lignite open cast mining systems: a preliminary status  

Energy Technology Data Exchange (ETDEWEB)

The application of a Compact Airborne Spectrographic Imager to assessment and monitoring of lakes in a lignite open cast mining area in central Germany is described. The imager was used in combination with additional ground experiments, such as field spectroscopy and water sampling. The spectral characteristics of an instrument under development for monitoring geochemical and hydrological processes are presented. Summary form only.

1999-07-01

9

Principium research of real-time neutron radiography in No. 300 reactor  

International Nuclear Information System (INIS)

The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper

2002-12-01

10

An intracranial aspergilloma with low signal on T2-weighted images corresponding to iron accumulation  

Energy Technology Data Exchange (ETDEWEB)

We present a case of cerebral aspergillosis in an immunocompetent patient. The MRI signal characteristics were compared with the histologic findings. Irregular low-signal zones were demonstrated between the wall of the abscess and the central necrosis on T2-weighted images; the pathology specimen revealed concentrated iron in these transitional zones but no hemosiderin. Iron is an essential element for the growth of fungal hyphae. The low-signal zones may represent the areas where there was active proliferation of aspergillus, and the unique location of the low signal may be a helpful imaging characteristic for the diagnosis of an aspergillus abscess. (orig.)

2001-07-01

11

Aicardi syndrome: a case report and radiologic findings; Sindrome de Aicardi: relato de caso e achados radiologicos  

Energy Technology Data Exchange (ETDEWEB)

The authors report the findings of Aicardi syndrome, a disease of unknown etiology composed of multiple spasms, chorioretinal lacunae and agenesis of the corpus callosum. They present a case of Aicardi syndrome with characteristic clinical presentation and magnetic resonance imaging findings. The disease, despite being considered rare, has characteristic imaging findings. Over the past years magnetic resonance imaging has improved its ability in demonstrating other findings besides agenesis of the corpus callosum, making the radiologist's role very important in the diagnostic suspicion of this disease. (author)

2008-07-01

12

Improved quadrant anode image sensor with microchannel plates  

Energy Technology Data Exchange (ETDEWEB)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-15

13

An improved quadrant anode image sensor with microchannel plates  

International Nuclear Information System (INIS)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes. (orig.).

1987-11-01

14

An improved quadrant anode image sensor with microchannel plates  

Science.gov (United States)

We describe a position-sensitive event-counting microchannel plate detector with a quadrant anode readout system that combines the advantages of several centroid-finding readout techniques. The relative amount of charge collected by each quadrant of the anode mounted behind the output side of the microchannel plate is used to localize each event. The position-sensitive area is about 80% of the active microchannel plate surface. By changing a single voltage a remote-controlled image magnification can be achieved. Due to a correction function that minimizes image distortions the imaging characteristics of this low-cost readout system are similar to those of expensive resistive anodes.

1987-11-01

15

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

16

Evaluation of performance and characteristics of neutron radiography and standardization  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total macroscopic cross section, the ...

1995-02-01

17

New Biomarkers Probing Depth of Cell Senescence Assessed by Laser Scanning Cytometry  

UK PubMed Central (United Kingdom)

The imaging analytical capabilities of laser scanning cytometer (LSC) have been used to assess morphological features considered to be typical of the senescent phenotype. The characteristic “flattening”...Full Text Available

2010-11-01

18

Clinical Assessment of Mirror Artifacts in Spectral-Domain Optical Coherence Tomography  

UK PubMed Central (United Kingdom)

Purpose.To investigate the characteristics of a spectral-domain optical coherence tomography (SD-OCT) image phenomenon known as the mirror artifact, calculate its prevalence, analyze...Full Text Available

2010-07-01

19

A Hybrid Strategy of Offline Adaptive Planning and Online Image Guidance for Prostate Cancer Radiotherapy  

UK PubMed Central (United Kingdom)

The offline adaptive radiotherapy (ART) has been used to effectively correct and compensate the prostate motion and reduce the required margin. The efficacy depends on the characteristics of...Full Text Available

2010-04-21

20

Photoacoustic imaging using an ultrasonic Fresnel zone plate transducer  

International Nuclear Information System (INIS)

A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer ...

2008-05-07

21

Model of quantum noise of shadow radiation images  

International Nuclear Information System (INIS)

Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems

22

Imaging findings of central nervous system neuroepithelial cysts  

Energy Technology Data Exchange (ETDEWEB)

Neuroepithelial cysts are rare and mostly asymptomatic cerebrospinal fluid (CSF)-like cysts. We describe herein the imaging findings in five patients with neuroepithelial cysts. Two cases of proven and three of presumed neuroepithelial cysts are presented. Three of five are located in the thalamus, a location which is not characteristic for neuroepithelial cysts. In the case of incidental finding of asymptomatic neuroepithelial cyst, clinical and radiological follow-up is indicated and surgical intervention is not necessarily warranted. (orig.) With 5 figs., 6 refs.

1998-05-01

23

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

24

Pulmonary nodule detection of chest phantom with CRT images; Comparison with conventional radiography (film-screen system) and FCR hardcopy  

Energy Technology Data Exchange (ETDEWEB)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided ...

1989-08-01

25

Pulmonary nodule detection of chest phantom with CRT images  

International Nuclear Information System (INIS)

Conventional Radiography, Fuji Computed Radiography (FCR) hardcopy and CRT images were evaluated about the detectability of pulmonary nodule using the chest phantom. Conventional and digitized chest radiographs (FCR) were used, including 45 normal cases and 45 abnormal cases with a variety pulmonary nodule. Observer performance tests were conducted to compare the effects on diagnostic accuracy of Conventional Radiography, FCR hardcopy and CRT images, and diagnostic accuracy was determined with receiver operating characteristic (ROC) analysis. ROC study was performed in which six radiologists were asked to locate nodule on three modalities. Two CRT monitors were used to observed CRT images. The left side CRT monitor was divided into two parts and displayed two images which were done as same image processing as FCR hardcopy. The right side CRT monitor was divided ...

1989-01-01

26

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...

1987-12-01

27

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in ...

1987-01-01

28

Multidate image analysis of forest degradation in equatorial Africa  

Energy Technology Data Exchange (ETDEWEB)

A section of the northern margin of the Guineo-Congolian rain forest of the Central African Republic is studied to determine to what extent deforestation is evolving. Three sites are presented to highlight the diversity in local environmental settings at the northern margin of the closed equatorial rain forest: the contiguous equatorial rain forest, the boundary between the closed rain forest and the grasslands, and a predominantly secondary grassland environment. Proven image processing procedures for determining land cover and vegetation vigor were applied to Landsat MSS data to determine land cover characteristics and identify alterations in land cover that indicate potentially degraded forest environments. Land cover was independently assessed using spectral signatures determined from a statistical clustering routine. The images presented and image analyses contribute insights and information to an ...

1990-12-01

29

Copper-64 Radiopharmaceuticals for PET Imaging of Cancer: Advances in Preclinical and Clinical Research  

British Library Electronic Table of Contents (United Kingdom)

Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...

2009-01-01

30

Characteristics of meningioma scintigraphy with multiple brain imaging agents  

International Nuclear Information System (INIS)

Purpose: To clarify the characteristics of meningioma scintigraphy with multiple brain imaging agents and to evaluate their roles in diagnosis of meningiomas. Methods: Blood flow, "9"9"mTc-ECD, "9"9"mTc-DTPA, and/or "9"9"mTc-MIBI brain imagings were performed in 21 patients with meningiomas (3 malignant, 18 benign) proved by surgery and pathology. CT/MRI examinations were also made within one month. Characteristics of meningioma images were analyzed and uptake ratios were calculated. Results: In 16 of 20 patients, increased radioactivity during the arterial phase in the blood flow image was seen. Concave round or oval defects with smooth contour in the cerebral cortex were observed in 17 of 19 patients with "9"9"mTc-ECD, depression of frontoparietal cortex was found in one case and no abnormality in the other. A homogeneous accumulation of radioactivity in area ...

1998-08-01

31

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis; Determination of optimum conditions of image processing  

Energy Technology Data Exchange (ETDEWEB)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image ...

1993-06-01

32

Technetium complexes as potential brain imaging agents  

International Nuclear Information System (INIS)

Single photon tomography using lipophilic tracers provides tomographic representations of regional blood flow. To penetrate a healthy blood-brain barrier requires that radiotracers either are fat-soluble or have an affinity for one of the selective blood-brain barrier transport systems. In recent years there has been an increasing interest to explore the ideal physical characteristics of "9"9"mTc for diagnostic problems of brain diseases. The development of radiopharmaceuticals for brain imaging including the intensively studied "9"9"mTc-propyleneamineoxime derivatives is discussed. (author).

33

Late relapse of metastatic non-seminomatous testicular germ cell tumours  

Energy Technology Data Exchange (ETDEWEB)

Although the majority of men presenting with non-seminomatous germ cell tumours (NSGCT) are cured, late relapse (occurring more than 2 years after obtaining a complete response to treatment) is increasingly recognized. The typical patterns of disease spread have been well-documented, but the findings at late relapse are more variable and less well-described. We discuss the phenomenon of late relapse, the characteristics of teratoma differentiated (TD), and the issue of long-term imaging surveillance of patients with NSGCT. The potential sites of late relapse of NSGCT and the associated spectrum of imaging appearances are illustrated.

2006-11-15

34

Late relapse of metastatic non-seminomatous testicular germ cell tumours  

International Nuclear Information System (INIS)

Although the majority of men presenting with non-seminomatous germ cell tumours (NSGCT) are cured, late relapse (occurring more than 2 years after obtaining a complete response to treatment) is increasingly recognized. The typical patterns of disease spread have been well-documented, but the findings at late relapse are more variable and less well-described. We discuss the phenomenon of late relapse, the characteristics of teratoma differentiated (TD), and the issue of long-term imaging surveillance of patients with NSGCT. The potential sites of late relapse of NSGCT and the associated spectrum of imaging appearances are illustrated.

2006-11-01

35

Radioiodinated phenoxyacetic acid derivatives as potential brain imaging agents, 2; Structure-biodistribution relationship  

Energy Technology Data Exchange (ETDEWEB)

In developing new brain imaging agents for single photon emission computed tomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The alpha,alpha-dimethylester derivative, amide derivatives and diamine derivatives, which were stable to hydrolysis, showed low blood activity levels following intravenous administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging radiopharmaceuticals with ...

1989-09-01

36

Paroxysmal nocturnal hemoglobinuria: a case report of MR, CT findings  

Energy Technology Data Exchange (ETDEWEB)

Paroxysmal nocturnal hemoglobinuria (PNH) is a rare, acquired disease involving multiple hematopoietic cell lines. Characteristics of PNH are intrinsic hemolytic anemia, iron deficiency anemia and venous thrombosis. We report a case of PNH with characterostoc MR and CT findings. The signal intensity of renal cortex was lower than that of medulla on both T1-and T2-weighted MR imaging. On T2 weighted MR images, the liver showed very low signal intensity but the signal intensity of the spleen was normal. On precontrast CT the attenuation of renal cortex was higher than that of renal medulla and the attenuation of liver was higher than that of the spleen. These findings of MR imaging and CT were the result from the deposition of hemosiderin in the cells of proximal convoluted tubules and transfusional hemosiderosis of liver.

1995-10-15

37

Intracranial Dural Metastasis of Ewing's Sarcoma: a Case Report  

International Nuclear Information System (INIS)

Ewing's sarcoma is a malignant bone tumor that can occur anywhere in the body, but it is most commonly observed in the long bones of the arms and legs, the pelvis and in the chest. The predominant sites of metastasis include the lung (38%), bone (including the spine; 31%), and the bone marrow (11%). Metastasis of Ewing's sarcoma to the central nervous system (CNS) is relatively rare, and most of the previous reports have demonstrated involvement of the bony calvarium or brain parenchyma. We describe here the imaging findings of dural metastasis of Ewing's sarcoma, and these imaging findings have not been previously reported on in the medical literature. In conclusion, dural metastasis of Ewing's sarcoma is very rare and its imaging characteristics are similar to those of a primary tumor, which mimic the findings of a schwannoma or meningioma. Despite its rarity, secondary Ewing's sarcoma may be included ...

2008-02-01

38

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis  

International Nuclear Information System (INIS)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image ...

1993-01-01

39

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...

1991-11-01

40

Clinical evaluation of life size image of Fuji computed radiography for detection of diffuse interstitial lung diseases  

International Nuclear Information System (INIS)

To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 ...

1991-01-01

41

MR evaluation of rectal carcinoma: pelvic phased-array coil versus endorectal-pelvic phased-array coil  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy of MR imaging using an endorectal-pelvic and a pelvic phased-array coil for preoperative local staging of rectal carcinoma. To determine preoperative staging, 38 patients with rectal carcinoma underwent MR imaging. All patients were examined with both an endorectal-pelvic and a pelvic phased-array coil. All underwent surgery and staging was pathologically confirmed. Two radiologists blinded to pathologic stage analyzed perirectal invasion and perirectal node metastasis, and scored according to a four-point scale. Radiologic and pathologic findings were correlated. Receiver operating characteristic (ROC) analysis of Wilcoxon statistic (W values) was used to compare diagnostic accuracy between the two different MR methods. Interobserver variation was measured using {kappa} statistics. For perirectal invasion, T1WI endorectal-pelvic phased-array coil images (reader 1:0. 854, reader ...

1998-10-01

42

Nodular fasciitis: correlation of MRI findings and histopathology  

Energy Technology Data Exchange (ETDEWEB)

Objective: To compare the histopathology of nodular fasciitis (NF) with the magnetic resonance imaging (MRI) findings in order to evaluate the basis of the MR signal characteristics. Design and patients: Ten patients with NF, nine females and 1 male, with an age ranging from 13 to 58 years (mean 26.8 years) were studied. MRI findings, available in all 10 patients, were compared with the histopathology in nine patients, and an area-to-area comparative study of the whole specimen section histopathology and MRI was performed in two patients. Results: On the basis of an excisional biopsy or resection specimen, the nine lesions were classified into myxoid (n=4), cellular (n=3) and fibrous (n=2) subtypes. Four myxoid lesions with a subcutaneous location showed a homogeneous SI comparable with muscle on T1-weighted images, high SI on T2-weighted images, and had homogeneous enhancement. One cellular lesion ...

2002-03-01

43

Moxel: A molar tooth voxel model for dosimetric studies  

Energy Technology Data Exchange (ETDEWEB)

Stylized numerical models of the tooth are usually employed in qualification procedure related to Electronic Paramagnetic Resonance in long-term accidental contamination dose reconstruction. In this work a voxel model was developed from the microCT image data set of a human non contaminated molar tooth. A stylized model, reproducing the characteristics of the voxel model, was also created in order to investigate the level of accuracy that can be obtained in this kind of study.

2010-02-15

44

Clinical helical tomotherapy commissioning dosimetry  

International Nuclear Information System (INIS)

Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are unique to tomotherapy are highlighted. Many beam characteristics can be measured automatically by an included megavoltage computed tomography imaging system. This greatly improves data collection efficiency.

2003-12-01

45

Vibration signature analysis of AFM images  

Energy Technology Data Exchange (ETDEWEB)

Vibration signature analysis has been commonly used for the machine condition monitoring and the control of errors. However, it has been rarely employed for the analysis of the precision instruments such as an atomic force microscope (AFM). In this work, an AFM was used to collect vibration data from a sample positioning stage under different suspension and support conditions. Certain structural characteristics of the sample positioning stage show up as a result of the vibration signature analysis of the surface height images measured using an AFM. It is important to understand these vibration characteristics in order to reduce vibrational uncertainty, improve the damping and structural design, and to eliminate the imaging imperfections. The choice of method applied for vibration analysis may affect the results. Two methods, the data dependent systems (DDS) analysis and the Welch`s periodogram averaging ...

1995-12-31

46

Medical image transmission via communication satellite. Evaluation of bone scintigraphy  

International Nuclear Information System (INIS)

As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6#+-#2.6% ...

47

Neutron radiography with the cyclotron, 4  

International Nuclear Information System (INIS)

A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented ...

1986-01-01

49

Hemodynamic characteristics of early stage hepatocellular carcinoma; In vivo evaluation with vascular imagings  

Energy Technology Data Exchange (ETDEWEB)

Hemodynamic characteristics were studied by using in vivo vascular imaging techniques in 17 resected early stage hepatocellular carcinoma (e-HCC) by comparing them with 49 resected advanced HCCs (ad-HCC) less than 3 cm in diameter. In this study, e-HCC was defined as the nodule being uniformly composed of well-differentiated HCC or adenomatous hyperplastic nodule containing well-differentiated HCC foci within the nodule. In vivo vascular imaging techniques are as follows; US angiography with intraarterial CO{sub 2} microbubbles were performed to assess the tumor arterial vascularity, and CT during arterial portography (CTAP) was performed to assess the portal perfusion within the nodule. Of 17 e-HCC nodules 5 were hypervascular, 5 were isovascular, 4 were hypovascular, and 3 were vascular spot in hypovascular pattern in contrast to 49 ad-HCC nodules, 43 of which were hypervascular and 6 were isovascular. Of 14 e-HCCs, 9 ...

1992-04-01

50

Study on the characterization of the neutron radiography facility in HANARO for two-phase flow research  

Energy Technology Data Exchange (ETDEWEB)

For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.

2001-01-01

51

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. The theory and ...

2001-01-01

52

Refrigerator operating experience on whole body MRI magnet systems  

International Nuclear Information System (INIS)

Several refrigerators for liquid helium and liquid nitrogen systems have been integrated successfully into IGC manufactured whole body Magnetic Resonance Imaging (MRI) magnet systems. The refrigerators have been tested in systems with magnetic fields of 0.6T to 1.5T. Tests were performed to study the effectiveness of the refrigerators, the magnetic field effects on the refrigerators, the effect of the refrigerators on the field uniformity and magnetic resonance image quality. The interface between the refrigerator and the whole body MRI magnet system cryostat was specifically designed to allow retrofit to the existing IGC magnet systems, while ensuring good heat transfer characteristics and good vibration isolation from the cryostat. The interface between the refrigerator and the cryostat and the refrigerator test results are presented.

1985-08-01

53

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

54

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

55

Surface characteristics and overlaying properties of flat-pressed wood plastic composites  

British Library Electronic Table of Contents (United Kingdom)

This study evaluated surface characteristics and overlaying properties of wood plastic composite (WPC) panels made from dry-blended rubber wood fiber-polypropylene (PP) powder formulations using a conventional flat-press process under laboratory conditions. Three levels of rubberwood fibers (Hevea brasiliensis), 40%, 50%, and 60%, based on the composition by weight, were mixed with the PP powder without and with 3% (based on weight) maleic anhydride grafted PP (MAPP) as a coupling agent. Contact angle measurements on the WPC samples were performed using a goniometer connected with a digital camera which collected one image per second. Roughness measurements, average roughness (R a), mean peak-to-valley height (R z), and maximum roughness (R y), were taken from the sanded samples along and ...

2011-01-01

56

Flame propagation characteristics and flame structures of zirconium particle cloud in a small-scale chamber  

British Library Electronic Table of Contents (United Kingdom)

Flame propagating through zirconium particle cloud in a small-scale vertical rectangle chamber was investigated experimentally. In the experiments, the zirconium quoted 99% purity was used and the diameter of particles was distributed 1?22 ?m. The zirconium dust was dispersed into the chamber by air flow and ignited by an electrode spark. A high-speed video camera was used to record the images of the propagating flame. Micro-thermocouples, schlieren optical system and microscopic lens were used to obtain temperature profiles and flame structure, respectively. Based on the experimental results, flame propagation characteristics and flame structure of zirconium particle cloud were analyzed. The propagation velocity of the flame is quite slow in the initial 14 ms and then accelerates to maxim...

2010-01-01

57

Adrenal incidentaloma: Does an adequate workup rule out surprises?  

British Library Electronic Table of Contents (United Kingdom)

Background Adrenal incidentaloma remains a diagnostic challenge. Despite well-established management guidelines, the long-term results of following these guidelines are unknown. We sought to determine how accurately these guidelines identify functioning incidentalomas and how often these guidelines result in adrenalectomy for benign tumors. Methods We catalogued adrenal incidentalomas from a retrospective review of 500 consecutive adrenalectomies at a single institution. The outcome measures studied were patient demographics, preoperative biochemical analysis, imaging characteristics, tumor size, type of operation performed, and postoperative histologic diagnosis. Results Eighty-one of the 500 adrenalectomies performed were for incidentalomas. Size was the only significant characteristic t...

2010-01-01

58

Introducing DeBRa: a detailed breast model for radiological studies  

Energy Technology Data Exchange (ETDEWEB)

Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom ...

2009-07-21

59

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one ...

2003-03-15

60

Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries  

International Nuclear Information System (INIS)

The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one ...

2003-03-01

61

Analysis and Assessment of Land Use Change in Alexandria, Egypt Using Satellite Images, GIS, and Modelling Techniques  

International Nuclear Information System (INIS)

Alexandria is the second largest urban governorate in Egypt and has seen significant urban growth in its modern and contemporary history. This study investigates the urban growth phenomenon in Alexandria, Egypt, using the integration of remote sensing and GIS. The urban physical expansion and change were detected using Landsat satellite images. The satellite images of years 1984 and 1993 were first geo referenced, achieving a very small RMSE that provided high accuracy data for satellite image analysis. Then, the images were classified using a tailored classification scheme with accuracy of 93.82% and 95.27% for 1984 and 1993 images respectively. This high accuracy enabled detecting land use/land cover changes with high confidence using a post-classification comparison method. One of the most important findings here is the loss of cultivated land in favour of urban expansion. If the ...

62

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

63

Soft x-ray microradiography and lithograph using a laser produced plasma source. Final report  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-03-01

64

Soft x-ray microradiography and lithograph using a laser produced plasma source  

Energy Technology Data Exchange (ETDEWEB)

Considering the hardware characteristics of the laser-induced plasma X-ray source and the limitations of the conventional cone-beam reconstruction algorithm, a general cone-beam reconstruction algorithm has been developed at our laboratory, in which the motion locus of the X-ray source is an arbitrary curve corresponding to at least a 2{pi} continuous horizontal angular displacement in the coordinate system of the specimen. The preliminary simulation shows that the general cone-beam reconstruction algorithm consistently results in visually satisfactory images.

1992-01-01

65

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

66

Fabrication of 10nm diameter carbon nanopores  

Energy Technology Data Exchange (ETDEWEB)

The addition of carbon to samples, during imaging, presents a barrier to accurate TEM analysis, the controlled deposition of hydrocarbons by a focused electron beam can be a useful technique for local nanometer-scale sculpting of material. Here we use hydrocarbon deposition to form nanopores from larger focused ion beam (FIB) holes in silicon nitride membranes. Using this method, we close 100-200nm diameter holes to diameters of 10nm and below, with deposition rates of 0.6nm per minute. I-V characteristics of electrolytic flow through these nanopores agree quantitatively with a one dimensional model at all examined salt concentrations.

2008-09-25

67

CT-pathologic correlation of focal area of ground-glass attenuation (GGA) in the peripheral lung  

Energy Technology Data Exchange (ETDEWEB)

We compared the characteristics on thin-section CT images with the histological structure of thirty-four surgically resected peripheral lung lesions 30 mm or less in diameter with a greater than 50% area of GGA on thin-section CT. Pathologically, focal area of GGA corresponded to alveolar replacement growth of tumor or interstitial fibrotic thickening of inflammation. It is considered that determination of the GGA in small peripheral lung lesions on thin-section CT is useful for the diagnosis of early adenocarcinomas. (author)

2001-07-01

68

Representation of uncertainty in computer vision using fuzzy sets  

Energy Technology Data Exchange (ETDEWEB)

Uncertainty in computer vision can arise at various levels. It can occur in the low level in the raw sensor input, and extends all the way through intermediate and higher levels. Ideally, at any level where decisions are being made on the basis of previous processing steps, a computer vision system must have sufficient flexibility for representation of uncertainty in any of these levels. The input cue representation portion of a computer vision system should maintain the information content of the original input images, while at the same time allowing for uncertainty in the identification of attributes required by other parts of the system for decision making. Processes such as edge detection, segmentation, and shape matching yield results which could bias higher level decision making, unless some framework is defined for the representation of uncertainty in the context of fuzzy set theory where membership values associated with the fuzzy sets contain a consistent ...

1986-02-01

69

Remote sensing monitoring method of hyperspectral and high-resolution for underground coal bed combustion  

Energy Technology Data Exchange (ETDEWEB)

Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface ...

2007-10-15

70

Radioiodinated phenoxyacetic acid derivatives as potential brain imaging agents, 2  

International Nuclear Information System (INIS)

In developing new brain imaging agents for single photon emission computed tomography (SPECT), we synthesized eleven radioiodinated phenoxyacetic acid derivatives and investigated the relationship between the chemical structure and in vivo characteristics. Biodistribution studies in mice revealed high initial brain uptake for all the compounds. Blood radioactivity level depended markedly upon the chemical stability of the compound. The #alpha#,#alpha#-dimethylester derivative (1e), amide derivatives (2a-c) and diamine derivatives (3a, b, 4), which were stable to hydrolysis, showed low blood activity levels following i.v. administration. Disappearance of the ester and amide compounds from the brain was rapid. However, the diamine derivatives displayed improved retention in the brain. Compounds 3a and 4 possessed the best combination of high brain uptake and sufficient retention to be useful as potential brain imaging ...

71

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement ...

72

Development of gamma-emitting, receptor binding radiotracers for imaging the brain and pancreas  

Energy Technology Data Exchange (ETDEWEB)

This progress report covers period from Nov. 1, 1989 to Aug. 31, 1990. The long term objective was to develop receptor-binding radiotracers for SPECT or PET imaging of CNS or peripheral nervous system. The specific chemistry aims, as understood on the basis of past findings, were: to synthesize and develop a more polar analogs of 4IQNB, possessing similar binding characteristics but eliminated more rapidly from the surrounding tissues and the target organ, to design a method of introducing a technetium chelating group onto a molecule or cholinergic agent without drastic lowering of its apparent affinity, to synthesize and develop radiotracers based on m-AChR antagonists selective for one of the subtypes of the receptor. The chemistry service aims were to prepare and characterize (R,R)- and (R,S)-4IQNB and derivatives, to provide the triazene intermediate to other investigators, and to provide ({sup 123}I)4IQNB for in vivo ...

1990-01-01

73

Canon's flat-panel detector  

International Nuclear Information System (INIS)

We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system ...

2002-12-01

74

Canon's flat-panel detector  

Energy Technology Data Exchange (ETDEWEB)

We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of ...

2002-12-01

75

Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging  

International Nuclear Information System (INIS)

Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope ...

76

Three-Dimensional Wing Kinematics and Aerodynamic Characteristics of a Beetle in Free Flight  

Science.gov (United States)

Detailed three dimensional wing kinematics and aerodynamic characteristics are experimentally presented for the free flight of a beetle, Allomyrina dichotoma, which has a pair of elytra (fore wings) and hind wings. The kinematic parameters of the wing motion, such as the wing tip trajectory, angle of attack, torsion angle, and camber deformation, are obtained from a 3D reconstruction technique that involves the use of two or three synchronized high-speed cameras to digitize various points marked on the wings. Our data show outstanding characteristics of wing deformation and flexibility in the free flight of the beetle. To find out the mechanism of aerodynamic force, the leading edge vortex (LEV) and trailing edge vortex (TEV) on both elytron and hind wing were observed by using smoke wire visualization and digital particle image velocimetry (DPIV) technique. Qualitative smoke lines in the region of the most intent vortex ...

2010-11-01

77

Radiologic findings of extraosseous Ewing's sarcoma  

International Nuclear Information System (INIS)

The purpose of this study is to evaluate the radiologic findings of the extraosseous Ewing's sarcoma. Six patients with pathologically confirmed extraosseous Ewing's sarcoma were retrospectively reviewed. Patients included two men and four women with an average age of 21.5 years (age range 9-48 years). Plain radiographs (six patients), magnetic resonance (MR) images (five patients), computed tomographic (CT) scans (three patients) and whole body scintigraphy (two patients) were reviewed and analyzed. Images were evaluated with regard to lesion location, size, margin, muscle or bone involvement and intrinsic imaging characteristics on CT and MRI. The tumors were located in the thigh (three patients), back (two patients) and upper arm (one patient). The tumors ranged in size from 2.3 cm to 7.5 cm (mean, 5.2 cm), were mainly well circumscribed and showed no evidence of calcification prior to treatment. ...

2005-09-01

78

MR imaging study on external hydrocephalus in infants: extracerebral space developmental and pathological enlargement  

International Nuclear Information System (INIS)

Objective: To analyze the characteristics of external hydrocephalus in infancy with MR imaging, and to explore the cause of accumulation of extracerebral fluid and the relation with brain development. Methods: Conventional magnetic resonance T_1 weighted imaging (T_1WI) and T_2 weighted imaging (T_2WI) were performed in 46 infants aged 2 years or younger with external hydrocephalus (EH), and the results were analyzed. They were divided into 7 age groups. The width of extractable space was measured on T_2WI and compared with normal standard. Results: EH mainly resulted from infection, subdural hematoma or subarachnoid hemorrhage, HIE, which were 67.4% (31/46 cases) of the cases; EH with unknown cause were 26.1% (12/46 cases). EH was mainly located at the foreside of cerebral convexity, of which 80.4% (37/46 cases )was predominantly in the subarachnoid space, 8.7% (4/46 cases) in subdural space, 10.9% was ...

2006-05-01

79

Imaging of reflection seismic and radar wavefields: Monitoring of steam-heated oil reservoirs and characterization of nuclear waste repositories  

Energy Technology Data Exchange (ETDEWEB)

A new three-dimensional (3D) acoustic modelling method was developed using a first-order hyperbolic wave system which was solved with explicit finite dfferences. The numerical solution of the 3D wave system provides a useful method for simulating evolution of a pressure field corresponding to compressional type waves. Existing two-dimensional (2D) elastic modelling algorithms were modified and fine-tuned for computationally efficient and realistic wave propagation simulations in complex structures. An original formulation of the 3D reverse time migration method was developed which is very accurate, does not suffer from unwanted evenescent energy, can image dips beyond 90{degree}, and does not generate multiple energy. Two case studies were performed that involved steam stimulation projects in the Cold Lake deposit. Simulations were performed during different phases of the steam stimulation process to examine the relation between reservoir properties and conditions ...

1994-12-31

80

Size and morphology of heavy-duty vehicle particle emissions; Raskaan ajoneuvokannan hiukkaspaeaestoen koko ja morfologia - HD-PM  

Energy Technology Data Exchange (ETDEWEB)

Formation of particles from heavy duty diesel and CNG vehicles was studied in laboratory conditions. PM, nano and soot mode particle emissions formed from buses of Euro 2-5 -emission levels were studied in relation to age and type approval characteristics of the vehicle. Characteristic particle emission factors from city driving were obtained by driving the buses on VTT's heavy duty chassis dynamometer applying the transient Braunschweig city cycle. The vehicles were a representative set of Euro 2 to 3 emission categories, supplemented with Euro 4-5 (EEV) -targeted CRT, CNG and DPF cars. Particle number emissions from Euro 4 to 5 buses were 1/100-1/1000 and mass emissions 1/10-1/100 of those of the current fleet. Particle emission from natural gas buses and after an advanced CRT trap contained almost entirely liquid < 60 nm nano particles, which will make filter mass based PM control very challenging in the near future. One ...

2006-10-15

81

Optical Images Due to Lenses and Mirrors  

Science.gov (United States)

... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...

83

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

84

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame ...

2000-07-01

85

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a ...

2000-01-01

86

New technetium-99m radiopharmaceuticals for brain imaging  

International Nuclear Information System (INIS)

Radiopharmaceuticals for brain imaging are used for the detection of ischemia, tumours and dementia associatied with disorders of the blood flow in the brain. The current radiopharmaceuticals for brain imaging have various limitations: 2-(F-18)fluoro-2-deoxyglucose (F-18-FDG) has a very short half-life. The physical properties of di-#beta#-(piperidinoethyl)-(Se-75)selenide (Se-75-PIPSE) and di-#beta#-(morpholinoethyl)-(Se-75)-selenide (Se-75-MOSE) are not ideal. Thallium-201 diethyldithricarbamate (T1-201-DDC) has unfavourable nuclidic characteristics, limited availability, a long half-life and high cost. I-123 in N-isopropyl-p-iodoamphetamine (I-123-IMP) and N,N,N'-trimethyl-N'-(2-hydroxy-3-methyl-5-iodobenzyl)-1,3-propanediamine (I-123-HIPDM) are not freely available and are expensive. N-13-labelled ammonia has a very short half-life. Technetium-99m hexamethylpropyleneamineoxime (Tc-99m-HM-PAO) is unstable both in vitro ...

1988-08-01

87

A comparison of cathode ray tube (CRT) and computed radiography (CR) diagnosis in mammography  

International Nuclear Information System (INIS)

Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both ...

1999-11-01

88

Visualization and measurement of pressurized multiphase flow using neutron radiography of JRR-3M system  

Energy Technology Data Exchange (ETDEWEB)

Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by which the pressure in ...

1998-01-01

89

Robust line width estimation  

Energy Technology Data Exchange (ETDEWEB)

Fabrication of diffused titanium optical guides on a LiNbO/sub 3/ crystal substrate requires precise quality assurance. Light couplers in particular must be positioned within micron specifications. This requirement is the reason that the width of lines detected during microscopic inspection of the crystal is such an important parameter for quality evaluation. To assist in the inspection of these optical guides, a line width estimation program has been developed for an IBM PC based microscope inspection system. A digital image processing approach is used to develop an algorithm which can be tailored by the user for specific signal and noise characteristics. Default filter parameters, which can be updated and saved interactively by the user, are stored in a file on disk. The final program can be executed stand-alone or through a commercially available, menu-driven, image processing software package. Details concerning the ...

1986-07-01

90

Involuntary Mental Time Travel and Its Effect on Prospective Teachers' Situational Intrinsic Motivations  

Science.gov (United States)

Recent cognitive psychological research has argued that involuntary mental time travel is an important individual difference variable that has the potential to affect an individual's motivation. However, this issue has not been empirically investigated in educational settings such as teacher education. Therefore, this study aimed to explore the possible effect of involuntary mental time travel on prospective teachers' situational intrinsic motivations in the classrooms during the period of a class hour. A total of 274 prospective teachers voluntarily participated in the study. Results showed that involuntary mental time travel into the past and into the future occurred in the classrooms even during the period of a class hour. The characteristics of the prospective teachers' involuntary memories/future images were evident. Most importantly, results revealed that the teaching-related positive future images significantly and ...

2010-12-01

91

HST/ACS observations of shell galaxies: inner shells, shell colours and dust  

CERN Document Server

AIM:Learn more about the origin of shells and dust in early type galaxies. METHOD: V-I colours of shells and underlying galaxies are derived, using HST Advanced Camera for Surveys (ACS) data. A galaxy model is made locally in wedges and subtracted to determine shell profiles and colours. We applied Voronoi binning to our data to get smoothed colour maps of the galaxies. Comparison with N-body simulations from the literature gives more insight to the origin of the shell features. Shell positions and dust characteristics are inferred from model galaxy subtracted images. RESULT: The ACS images reveal shells well within the effective radius in some galaxies (at 1.7 kpc in the case of NGC 5982). In some cases, strong nuclear dust patches prevent detection of inner shells. Most shells have colours which are similar to the underlying galaxy. Some inner shells are redder than the galaxy. All six shell galaxies show out of dynamical ...

2007-01-01

92

Ganglioneuromas in childhood: MRI and CT characteristics  

International Nuclear Information System (INIS)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors ...

2000-05-01

93

Evaluation of computer-aided detection of lesions in mammograms obtained with a digital phase-contrast mammography system  

Energy Technology Data Exchange (ETDEWEB)

A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-{mu}m-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of ...

2009-12-15

94

Evaluation of FCR system by means of NEQ(u)  

Energy Technology Data Exchange (ETDEWEB)

A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We concluded that it is necessary to compare with the screen-film system in a frequency ...

1991-07-01

95

Evaluation of FCR system by means of NEQ(u)  

International Nuclear Information System (INIS)

A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We concluded that it is necessary to compare with the screen-film system in a frequency ...

1991-01-01

96

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of approx 1nA and a ...

2002-01-01

99

Java Image I/O for VICAR, PDS, and ISIS  

Science.gov (United States)

This library, written in Java, supports input and output of images and metadata (labels) in the

2011-01-01

100

Water management studies in PEM fuel cells, part IV: Effects of channel surface wettability, geometry and orientation on the two-phase flow in parallel gas channels  

British Library Electronic Table of Contents (United Kingdom)

In this study, the effects of channel surface wettability, cross-sectional geometry and orientation on the two-phase flow in parallel gas channels of proton exchange membrane fuel cells (PEMFCs) are investigated. Ex situ experiments were conducted in flow channels with three different surface wettability (hydrophilically coated, uncoated, and hydrophobically coated), three cross-sectional geometries (rectangular, sinusoidal and trapezoidal), and two orientations (vertical and horizontal). Flow pattern map, individual channel flow variation due to maldistribution, pressure drop and flow visualization images were used to analyze the two-phase flow characteristics. It is found that hydrophilically coated gas channels are advantageous over uncoated or slightly hydrophobic channels regarding un...

2011-01-01

101

Turbulent Flame Speed Characteristics Of High-Pressure, Lean Premixed Methane / Air Flames  

Energy Technology Data Exchange (ETDEWEB)

High-pressure, lean, premixed methane/air flames are investigated experimentally to determine turbulent flame speeds (s{sub T}). The results are based on the statistical analysis of single-shot OH-PLIF images. The influences of pressure (p = 5 - 14.4 bars) and equivalence ratio ( {phi} 0.43 - 0.56) on the turbulent flame speed are discussed. The analysis reveals that s{sub T} is independent of pressure and it depends strongly on equivalence ratio. The turbulent flame speed at {phi} = 0.56 is about 3 times higher than at {phi} = 0.43 because of the higher integral reaction rate caused by the higher fuel concentration and therefore higher adiabatic flame temperature. (author)

2005-03-01

102

The temporal evolution of coronal loops observed by GOES-SXI  

CERN Document Server

We study the temporal evolution of coronal loops using data from the Solar X-ray Imager (SXI) on board of GOES-12. This instrument allows us to follow in detail the full lifetime of coronal loops. The observed light curves suggest three somewhat distinct evolutionary phases: rise, main, and decay. The durations and characteristic timescales of these phases are much longer than a cooling time and indicate that the loop-averaged heating rate increases slowly, reaches a maintenance level, and then decreases slowly. This suggests that a single heating mechanism operates for the entire lifetime of the loop. For monolithic loops, the loop-averaged heating rate is the intrinsic energy release rate of the heating mechanism. For loops that are bundles of impulsively heated strands, it is an indication of the frequency of occurrence of individual heating events, or nanoflares. We show that the timescale of the loop-averaged heating rate is proportional ...

2006-01-01

103

The surface topography of the choroid plexus. Environmental, low and high vacuum scanning electron microscopy  

British Library Electronic Table of Contents (United Kingdom)

Environmental scanning electron microscopy (ESEM) allows the examination of hydrated and dried specimens without a conductive metal coating which could be advantageous in the imaging of biological and medical objects. The aim of this study was to assess the performance and benefits of wet-mode and low vacuum ESEM in comparison to high vacuum scanning electron microscopy (SEM) using the choroid plexus of chicken embryos as a model, an organ of the brain involved in the formation of cerebrospinal fluid in vertebrates. Specimens were fixed with or without heavy metals and examined directly or after critical point drying with or without metal coating. For wet mode ESEM freshly excised specimens without any pre-treatment were also examined. Conventional high vacuum SEM revealed the characterist...

2011-01-01

104

Photosensitivity and imaging characteristics of ion-implanted PLZT ceramics  

International Nuclear Information System (INIS)

We reported in previous papers that both the near-uv and the visible photosensitivities of ferroelectric-phase PLZT (lead lanthanum zirconate titanate) ceramics are increased by as much as four orders of magnitude by ion implantation or a combination of thermal diffusion of Al and ion implantation. New results are presented here on high-energy (1 MeV) implants of Al and Ni and coimplants of Al + Ne and Ni + Ne, and these results are compared with earlier 500 keV implants of Al and Cr and coimplants of Al + Ne and Cr + Ne as surface modification techniques for increasing the visible photosensitivity of PLZT. The important role of grain size in determining optimum contrast and resolution of stored optical information is described in terms of new experimental results.

1985-08-12

105

Performance of a low cost solar paraboloidal dish steam generating system  

Energy Technology Data Exchange (ETDEWEB)

This paper presents the design, development and performance characteristics of a low cost solar steam generating system which incorporates recent design and materials innovations of parabolic dish technology. The concentrator is a deep dish of rather imperfect optics, made of silvered polymer reflectors fitted in the aluminum frame of a satellite communication dish. Conventional cavity receivers tend to be inadequate for this concentrator. Semi-cavity and modified cavity receivers, thermally optimised, with the fuzzy focal image have, therefore, been investigated. Preliminary field measurements and cost, as well as performance analyses of the system, indicate a solar to steam conversion efficiency of 70-80% at 450{sup o}C and a collector system cost of Rs 8000-9000/m{sup 2} (1 US dollar = Rs, 40.0). (author)

2000-05-01

106

PIV measurements of flows around the wind turbines with a flanged-diffuser shroud  

British Library Electronic Table of Contents (United Kingdom)

The wind turbines with a flanged-diffuser shroud-so called ?wind lens turbine??-are developed as one of high performance wind turbines by Ohya et al. In order to investigate the flow characteristics and flow acceleration, the paper presents the flow velocity measurements of a long-type and a compact-type wind turbines with a flanged-diffuser shroud by particle image velocimetry. In the case of the long type wind turbine, the velocity vectors of the inner flow field of the diffuser for turbine blades rotating and no blades rotating are presented at Reynolds number, 0.9?105. Furthermore the flow fields between with and without rotating are compared. Through the PIV measurement results, one can realize that the turbine blades rotating affects as suppress the disturbance and the flow separatio...

2008-01-01

107

Morphological characteristics and medium-term evolution of the beaches between Ceuta and Cabo Negro (Morocco)  

British Library Electronic Table of Contents (United Kingdom)

This work presents the results of a combined study on the beach morphology and the evolution at short- and medium-term of the littoral between Ceuta and Cabo Negro (Morocco). It is an interesting sector showing a great increase of human occupation and coastal structures. The monitoring program allowed for the reconstruction of the beach morphological behavior and the seasonal changes. The studied beaches presented reflective profiles recording little seasonality, with the most notable morphological changes being strictly related to storms. Surf Similarity and Surf Scaling parameters highlighted the existence of intermediate and reflective beach states, characterized by plunging breakers. Aerial photographs and a satellite image have been geo-referenced and elaborated with GIS tools to reco...

2007-01-01

108

Large (≥2cm) non-hypervascular nodules depicted on MRI in the cirrhotic liver: fate and implications  

British Library Electronic Table of Contents (United Kingdom)

Aim To determine the fate and clinical implication of large (?2cm), non-hypervascular nodules depicted on magnetic resonance imaging (MRI) in the cirrhotic liver. Materials and methods In 21 patients with cirrhosis (14 hepatitis B, two ethanol abuse, four cryptogenic, one Wilson's disease), 25 large (?2cm in the longest dimension) non-hypervascular nodules were identified on dynamic MRI. The implications for diagnosis of the initial size, contour, and signal characteristics on MRI in addition to patients' age and cause of cirrhosis were assessed in our analysis. Results Twelve (75%) out of 16 lesions were malignant or potentially-malignant from 14 hepatitis B patients, while seven (78%) of the nine lesions from other patients were benign (p=0.016). The mean age of the patients who ha...

2008-01-01

109

Landscape pattern MACRS analysis and the optimal utilization of Shiyang River Basin based on RS and GIS approach  

British Library Electronic Table of Contents (United Kingdom)

Chose the arid interior district Shiyang River basin four issues of Landsat/TM images from 1986 to 2006 to visually interpret, and analyze the natural succession of ecological environment and the landscape pattern characteristic under the human activity interference. The results showed that in past 20years, the number of landscape patch has increased, but the average patch size was decreasing, which explained that the landscape fragmentation degree was increasing, the landscape integrity was declining. The edge density of landscape remained invariable basically, which explained its stability maintained good. The diversity and evenness index continually enhanced, the diversity increased from 0.73 in 1986 to 0.84 in 2006. The mean core patch area of study area reduced from134.47hm2 in 1994 t...

2009-01-01

110

High-energy x-ray microscopy techniques for laser-fusion plasma research at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Multi-kilo-electron-volt x-ray microscopy will be an important laser-produced plasma diagnostic at future megajoule facilities such as the National Ignition Facility (NIF). However, laser energies and plasma characteristics imply that x-ray microscopy will be more challenging at NIF than at existing facilities. We use analytical estimates and numerical ray tracing to investigate several instrumentation options in detail, and we conclude that near-normal-incidence single spherical or toroidal crystals may offer the best general solution for high-energy x-ray microscopy at NIF and similar large facilities. Apertured Kirkpatrick{endash}Baez microscopes using multilayer mirrors may also be good options, particularly for applications requiring one-dimensional imaging over narrow fields of view. {copyright} 1998 Optical Society of America

1998-04-01

111

Clinical and metabolic characteristics of polycystic ovary syndrome without polycystic ovary: a pilot study on Chinese women  

British Library Electronic Table of Contents (United Kingdom)

Objective To demonstrate clinical features of a patient subgroup presenting with polycystic ovary syndrome (PCOS) without polycystic ovary morphology. Design Retrospective study. Setting Hospital-based IVF center. Patient(s) In the present study, 876 PCOS patients were selected from women who visited the Reproductive Medicine Center at Shandong Provincial Hospital, Shandong University, between September 2004 and October 2006. Women with PCOS were divided into two groups based on ultrasound image: group A, PCOS patients with classic polycystic ovary (n = 800); group B, PCOS patients without polycystic ovary morphology (n = 76). The following available data were analyzed in the large cohort of women: body height, weight, waistline, hip circumference, hirsutism scores, family history, serum s...

2008-01-01

112

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

113

The Requirement for Sodium as a Micronutrient by Species Having the C4 Dicarboxylic Photosynthetic Pathway  

Science.gov (United States)

Six species having characteristics of plants with the C4 dicarboxylic photosynthetic pathway, Echinochloa utilis L. Ohwi et Yabuno (Japanese millet), Cynodon dactylon L. (Bermuda grass), Kyllinga brevifolia Rottb., Amaranthus tricolor L. cv. Early splendour, Kochia childsii Hort., and Portulaca grandiflora Hook (rose moss), responded decisively to 0.1 milliequivalent per liter NaCl supplied to their culture solutions initially containing less than 0.08 microequivalent per liter Na. Chlorosis and necrosis occurred in leaves of plants not receiving sodium. Portulaca failed to set flower in the sodium-deficient cultures. Under similar conditions Poa pratensis L. (Kentucky blue grass) having characteristics of the C3 photosynthetic pathway made normal growth and did not respond to the addition of sodium. It is concluded from these results and previously reported work that sodium is generally essential for species having the C4 pathway but not for ...

1972-01-01

114

In vitro and in vivo study of {sup 99m}Tc-MIBI encapsulated in PEG-liposomes: a promising radiotracer for tumour imaging  

Energy Technology Data Exchange (ETDEWEB)

Encapsulation of technetium-99m sestamibi ({sup 99m}Tc-MIBI) in polyethyleneglycol-liposomes ({sup 99m}Tc-MIBI-PEG-liposomes) could extend the duration of its circulation in blood and alter its biodistribution, enabling its concentration in tumours to be increased. An original method to encapsulate {sup 99m}Tc-MIBI in PEG-liposomes is described. The {sup 99m}Tc-MIBI-PEG-liposomes were compared with free {sup 99m}Tc-MIBI with respect to (a) tumour availability (b) ability to distinguish between chemotherapy-sensitive and -resistant cells and (c) uptake ratio in tumour imaging. PEG-liposomal systems composed of distearoylphosphatidylcholine/cholesterol/PEG{sub 2000}-distearoyl phosphatidylethanolamine and lissamine-rhodamine B-labelled liposomes were used. The encapsulation of {sup 99m}Tc-MIBI in liposomes was achieved using the K{sup +} diffusion potential method. We compared the uptake of free versus encapsulated {sup 99m}Tc-MIBI by sensitive and resistant ...

2003-04-01

115

64-slice multidetector coronary CT angiography: in vitro evaluation of 68 different stents  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to test a large sample of different coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in 64-slice multidetector-row computed tomography (MDCT) in vitro and to provide a catalogue of currently used coronary artery stents when imaged with state-of the-art MDCT. We examined 68 different coronary artery stents (57 stainless steel, four cobalt-chromium, one cobalt-alloy, two nitinol, four tantalum) in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70). Stents were imaged in axial orientation with standard parameters: 32x0.6 collimation, pitch 0.24, 680 mAs, 120 kV, rotation time 0.37 s. Four different image reconstructions were obtained with varying convolution kernels and section thicknesses: (1) soft, 0.6 mm, ...

2006-04-15

116

Research and Development Program in Reactor Diagnostics and Monitoring with Neutron Noise Methods. Stage 13. Final report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results obtained during Stage 13 of a long-term research and development program concerning the development of diagnostics and monitoring methods for nuclear reactors. A brief proposal for the continuation of this program in Stage 14 is also given at the end of the report. The program executed in Stage 13 consists of three parts and the work performed in each part is summarized below. 1. Study of criticality, neutron kinetics and neutron noise in molten salt reactors (MSR). Although the original goal of the investigations of the MSR in Stage 13 was to calculate the neutron noise induced by the fluctuations of the fuel temperature, the study, solution and interpretation of the static problem, as well as to define an approximate version of the point kinetic approximation was necessary to perform. As it turned out, these tasks in themselves were more involved, and also very edifying, to solve. Hence, in this report, we confine the study of the reactor physics of ...

2008-06-15

117

Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm (n=4), intramural bleeding (n=2) and type-B aortic dissection (n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can ...

2003-07-01

118

Performance study of teleradiology network systems with CRT monitors. ROC analysis of an observation study of simulated lung nodules  

International Nuclear Information System (INIS)

To evaluate the diagnostic performance of commercially available CRT monitors used in a teleradiology system by determining the rate of detection of simulated lung nodules. Three types of CRT monitors were tested in the observation study. They had matrix sizes of 1024 x 768 (16 inches, color), 1024 x 768 (20 inches, color) and 1600 x 1125 (24 inches, black and white). Twenty chest radiographs were obtained by Fuji computed radiography (FCR) of an anthropomorphic chest phantom with ten simulated nodules on its surface. These FCR films were digitized by a film digitizer with 125 DPI (1024 x 1024 matrix sizes) and 12 bit gray scales, and the image data were transferred from Shinshu University Hospital to other hospitals where interpretation was carried out by the radiologists. Ten radiologists of three hospitals were asked to interpret independently both the original FCR films and the images shown on the CRT monitors and to indicate the presence ...

119

Multitemporal analysis of satellite data and their use in the monitoring of the environmental impacts of open cast lignite mining areas in Eastern Germany  

Energy Technology Data Exchange (ETDEWEB)

The use and application of remote sensing data for monitoring the environmental impacts of open cast lignite mining in Eastern Germany is described. This investigation is based on the digital analysis of several Landsat-TM and ERS-1 data sets acquired from 1989 to 1994. The characteristics of the imagery enable quantitative analysis of different open cast mine features, such as waste, water bodies, change of land use, reclamation processes and estimation of vegetation cover in the affected areas. On the basis of the Maximum Likelihood Classification of Landsat Thematic Mapper (TM) data the open cast mining areas were separated into bare open cast areas and areas of less and dense vegetation. The bare open cast areas were classified with respect to type of different sediments and the vegetation was seperated into different classes according to the age of the vegetation and the density cover. Apart from these, water bodies within the mining areas were classified into ...

1998-08-01

120

Magnetic resonance imaging of cerebral anomalies in subjects with resistance to thyroid hormone  

Energy Technology Data Exchange (ETDEWEB)

Resistance to thyroid hormone (RTH) is an autosomal dominant disease caused by mutations in the human thyroid receptor beta gene on chromosome 3. Individuals with RTH have an increased incidence of attention deficit hyperactivity disorder (ADHD). The purpose of this study was to search for developmental brain malformations associated with RTH. Forty-three subjects (20 affected males [AM], 23 affected females [AF]) with resistance to thyroid hormone and 32 unaffected first degree relatives (18 unaffected males [UM], 14 unaffected females [UF]) underwent MRI brain scans with a volumetric acquisition that provided 90 contiguous 2 mm thick sagittal images. Films of six contiguous images beginning at a standard sagittal position lateral to the insula were analyzed by an investigator who was blind with respect to subject characteristics. The presence of extra or missing gyri in the parietal bank of the Sylvian fissure (multimodal ...

1995-06-19

121

Investigation of sulfonated aromatic compound (SAC) modification to nylon film. 2. Study of SAC sorption isotherm and atomic force microscopic characterization of nylon surfaces  

Energy Technology Data Exchange (ETDEWEB)

Nylon 6 and nylon 66 films have been treated with aqueous sulfonated aromatic compound (SAC) solutions at concentrations ranging from 0.005 to 1.0 wt%. SAC uptakes at different treatment concentrations were measured and found to follow a BET isotherm. The surface morphologies of nylon film samples, including the original and SAC-treated films, have been characterized by atomic force microscopy (AFM). For untreated nylon 6 and nylon 66 films, AFM images show a randomly distributed fibrillar surface structure. Characteristic widths of fibrils in the nylon 66 and 6 films were 150-225 and 75-150 nm, respectively. For SAC-treated nylon films, the AFM images revealed that the surfaces of the films became covered with nodule-like features having a diameter range of 25-60 nm. AFM analysis provides evidence that SAC treatment deposited a surface coating on nylon films. AFM images of SAC-treated nylon films ...

1995-08-01

122

View larger image for ISS022-E-26137 - Earth Sciences and Image ...  

Science.gov (United States)

The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...

123

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

124

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

125

Advances in Imaging of Vertebral and Spinal Cord Injury  

UK PubMed Central (United Kingdom)

Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available

2010-04-01

126

3 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...

127

(Hadamard transform imaging)  

Science.gov (United States)

This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)

1990-01-01

128
130

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

131
138

Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy  

UK PubMed Central (United Kingdom)

In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available

139

Image Engine: an object-oriented multimedia database for storing, retrieving and sharing medical images and text.  

UK PubMed Central (United Kingdom)

This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available

1993-01-01

147

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

148

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-15

149

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-01

150

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...

2010-01-01

151

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

152

Esters useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

1981-08-18

153

Esters useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

154

Amides useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula

1981-07-21

155

Amides useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.

156

Image-enhancement applications at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.

1982-06-01

157

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...

2007-04-15

158

Thermal infrared spectra of surface rocks. Comparison of in the laboratory, in situ, and remote sensing data; Chihyo ganseki no netsusekigaiiki bunko tokusei. Chijo sokutei data to remote sensing data no hikaku  

Energy Technology Data Exchange (ETDEWEB)

An ASTER (advanced spaceborne thermal emission and reflection radiometer) is one of the image sensors. It is to be installed in an earth survey polar orbit platform satellite, EOS-AM1, which is to be launched in 1998, and it is going to start its operation. Data observed by the thermal infrared remote sensing of ASTER include the spectral emissivity, and the spectral emission reflectivity which is expressed by the function of temperature. It is required to overcome technical problems how to extract the spectral emissivity from the observed data. The spectral emissivity extracted from the remote sensing data by the MMD method, measured for samples collected in Cuprite area, Nevada, and/or measured at sampled points were compared to each other and discussed. The hemisphere spectral reflectivity, which is indirect spectral emissivity, agreed well with the direct spectral emissivity. Data suggesting the establishment of Kirchhoff`s law were obtained even for the ...

1996-10-01

159

Seismic migration and absorbing boundaries with a one-way wave system for heterogeneous media  

Energy Technology Data Exchange (ETDEWEB)

A first-order one-way wave system has been created based on characteristic analysis of the acoustic wave system and optimization of the dispersion relation. The authors demonstrate that this system is equivalent to a third-order scalar partial-differential equation which, for a homogeneous medium, reduces to a form similar to the 45{degree} paraxial wave equation. This system describes accurately waves propagating in a 2D heterogeneous medium at angles up to 75{degree}. The one-way wave system representing downgoing waves is used for a modified reverse time migration method. As a wavefield extrapolator in migration, the downgoing wave system propagates the reflection events backwards to their reflectors without scattering at the discontinuities in the velocity model. Hence, images with amplitudes proportional to reflectivity can be obtained from this migration technique. They present examples of the application of the new migration method to ...

1996-07-01

160

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the package is based on a ...

1999-07-01

161

MRI in combined subacute degeneration of the spinal cord; MRT bei funikulaerer Myelose  

Energy Technology Data Exchange (ETDEWEB)

The MRI morphology in combined subacute degeneration has only rarely been reported. We describe two patients suffering from subacute combined degeneration of the spinal cord on the basis of a deficiency of vitamin B{sub 12}. In both patients characteristic hyperintense areas on T{sub 2}-weighted images in the posterior columns of the cervical and thoracic cord without contrast enhancement were demonstrated by MRI. (orig.) [Deutsch] Bisher liegen zur wenige Beschreibungen der MR-Morphologie bei funikulaerer Myelose vor. Wir beschreiben zwei Patienten mit den klinischen Zeichen einer funikulaeren Myelose auf der Basis eines Vitamin B{sub 12}-Mangels. Bei beiden konnten mit der MRT charakteristische Signalanhebungen im T{sub 2}-gewichteten Bild in den Hinterstraengen des zervikalen und thorakalen Rueckenmarks gezeigt werden. Eine Kontrastmittelaufnahme war nicht nachweisbar. (orig.)

1999-06-01

162

Low-frequency fields - sources and exposure; Niederfrequente Felder - Quellen und Exposition  

Energy Technology Data Exchange (ETDEWEB)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe) [Deutsch] Nach einer kurzen Diskussion der Begriffsdefinitionen und einer Einfuehrung in die Messtechnik werden die Charakteristika verschiedener niederfrequenter Felder und ihre Ursachen anhand typischer ...

1993-06-01

163

Intense luminescence from porous ZnSe layers  

International Nuclear Information System (INIS)

We report on the possibility to prepare ZnSe porous layers with different degrees of porosity by means of electrochemical methods. The prepared porous structures were characterized using scanning electron microscopy (SEM), photoluminescence (PL) and cathodoluminescence (CL) techniques. The PL of the as-grown material and porous layers measured at low temperatures (10 K) was found to be dominated by an emission band at 2.796 eV as well as a band at 2.700 eV with several phonon replicas. The analysis of the dependence of these bands upon the excitation power density and temperature suggests that free-to-bound and respectively donor-acceptor electron transitions are responsible for the emission bands involved. The comparison of SEM and CL images taken from the same porous regions demonstrated that cathodoluminescence intensity from layers with small characteristic sizes of the porous entities (around 50 nm) is weaker than that inherent in bulk ...

164

Electrical properties of inalp native oxides for metal-oxide-semiconductor device applications  

Science.gov (United States)

Data are presented on the insulating properties and capacitance-voltage (CV) characteristics of metal-oxide-semiconductor (MOS) device-thickness (below approx. 100 nm) native oxides formed by wet thermal oxidation of thin InAlP epilayers lattice matched to GaAs. Low leakage current densities of J=1.4 x 10-9 A/cm2 and J=8.7 x 10-11 A/cm2 are observed at an applied field of 1 MV/cm for MOS capacitors fabricated with 17 nm and 48 nm oxides, respectively. TEM images show that the In-rich interfacial particles which exist in 110 nm oxides are absent in 17 nm oxide films. Quasi-static capacitance-voltage measurements of MOS capacitors fabricated on both n-type and p-type GaAs show that the InAlP oxide-GaAs interface is sufficiently free of traps to support inversion, indicating an unpinned Fermi level. These data suggest that InAlP native oxides may be a viable insulator for GaAs MOS device applications.

2004-09-01

165

Effects of extreme pressure additive chemistry on rolling element bearing surface durability  

Energy Technology Data Exchange (ETDEWEB)

Lubricant additives have been known to affect rolling element bearing surface durability for many years. Tapered roller bearings were used in fatigue testing of lubricants formulated with gear oil type additive systems. These systems have sulfur- and phosphoruscontaining compounds used for gear protection as well as bearing lubrication. Several variations of a commercially available base additive formulation were tested having modified sulfur components. The variations represent a range of ''active'' extreme pressure (EP) chemistries. The bearing fatigue test results were compared with respect to EP formulation and test conditions. Inner ring near-surface material in selected test bearings was evaluated on two scales: the micrometer scale using optical metallography and the nanometer scale using transmission electron microscopy (TEM). Focused-ion beam (FIB) techniques were used for TEM specimen preparation. Imaging and chemical ...

2007-08-01

166

Effect of coal rank and mineral matter on gasification reactivity of coal char treated at high temperature; Netsushorishita sekitan char no gas ka tokusei ni taisuru tanshu oyobi kobutsushitsu no eikyo  

Energy Technology Data Exchange (ETDEWEB)

In the wide range from brown coal to anthracite, an investigation was made of effects of heat treatment on physical/chemical properties and of coal rank dependence. For the experiment, 12 kinds of coal samples were used, and for heat treatment, the fluidized bed heated by the electric furnace and the infrared-ray gold image furnace were used. To examine characteristics of the heat-treated coal char, conducted were oxygen gasification, TPD measurement, XRD measurement, alkali metal measurement, and pore distribution measurement. The following were obtained from the experiment. The gasification reaction rate of the char heat-treated in the temperature range between 900{degree}C to 1700{degree}C decreases with a rise of the temperature of heat treatment, and the degree of decrease in the rate depends on coal rank. The order of gasification rate between coal ranks depends on the temperature of heat treatment, and the lower the heat treatment ...

1996-10-28

167

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...

2006-12-01

168

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented ...

2009-12-01

169

Computed tomography (CT) in renal trauma  

International Nuclear Information System (INIS)

CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of and sometimes correctly diagnose vascular lesions, such as renal infarction, angiography remains the ...

1987-01-01

170

Assembly of Linear Nano-Chains from Iron Oxide Nanospheres with Asymmetric Surface Chemistry  

Science.gov (United States)

Besides the multifunctionality, another equally important aspect of nanoparticles is their engineerability to control the geometrical and chemical properties during fabrication. In this work, we exploited this aspect to define asymmetric surface chemistry of an iron oxide nanosphere by controlling the topology of ligand expression on its surface resulting in a particle with two faces, one displaying only amines and the other only thiols. Specifically, amine-functionalized iron oxide nanospheres were attached on a solid support via a crosslinker containing a disulfide bridge. Liberation of the nanosphere using thiolytic cleavage created thiols on the portion of the particle's surface that interacted with the solid support. Employing a solid-phase strategy and a step-by-step addition of particles, the two unique faces on the same nanosphere served as fittings to assemble them into linear nano-chains. Assembly of chains with various lengths and aspect ratios was controlled by the size and ...

2011-01-06

171

Artificial receptor for peptide recognition in protic media: The role of metal ion coordination  

International Nuclear Information System (INIS)

The production of molecularly imprinted polymers (MIPs) for the recognition of C-terminal cholecystokinin pentapeptide (CCK-5) in the presence of metal ion is reported. The MIPs were produced under the same molar ratio of template to monomers (acrylamide, N,N'-methylene bisacrylamide) in the presence or absence of nitrilotriacetic acid-nickel (Ni-NTA) complex. Scanning electron microscopy images of MIPs were obtained in an attempt to correlate the adsorption characteristics with polymer's morphology. Subsequently Ni2+ was removed and substituted by other divalent ions such as Mg2+, Fe2+, Zn2+, Co2+ and Cu2+. It was found that polymers containing the metal ion complex with the order Fe-NTA, Ni-NTA and Cu-NTA presented lower dissociation constant values than the rest thus exhibiting stronger guest binding activity. The percentage of theoretical maximum binding sites Bmax was almost the same for these ions, indicating that the ion-template ...

2008-08-25

172

Nonphotochemical Hole-Burning Imaging Studies of in vitro Carcinoma and Normal Cells Utilizing a Mitochondrial Specific Dye  

Energy Technology Data Exchange (ETDEWEB)

Low temperature Nonphotochemical Hole Burning (NPHB) Spectroscopy of the dye rhodamine 800 (MF680) was applied for the purpose of discerning differences between cultured normal and carcinoma ovarian surface epithelial (OSE) cells. Both the cell lines were developed and characterized at the Mayo Clinic (Rochester, MN), with the normal cell line having been transfected with a strain of temperature sensitive Simian Virus 40 Large T Antigen (SV40) for the purpose of extending the life of the cell culture without inducing permanent changes in the characteristics of the cell line. The cationic lipophilic fluorophore rhodamine 800 preferentially locates in in situ mitochondria due to the high lipid composition of mitochondria and the generation of a large negative membrane potential (relative to the cellular cytoplasm) for oxidative phosphorylation. Results presented for NPHB of MF680 located in the cells show significant differences between the two cell lines. The ...

2002-06-27

173

Nonphotochemical Hole-Burning Imaging Studies of In Vitro Carcinoma and Normal Cells Utilizing a Mitochondrial Specific Dye  

Energy Technology Data Exchange (ETDEWEB)

Low temperature Nonphotochemical Hole Burning (NPHB) Spectroscopy of the dye rhodamine 800 (MF680) was applied for the purpose of discerning differences between cultured normal and carcinoma ovarian surface epithelial (OSE) cells. Both the cell lines were developed and characterized at the Mayo Clinic (Rochester, MN), with the normal cell line having been transfected with a strain of temperature sensitive Simian Virus 40 Large T Antigen (SV40) for the purpose of extending the life of the cell culture without inducing permanent changes in the characteristics of the cell line. The cationic lipophilic fluorophore rhodamine 800 preferentially locates in in situ mitochondria due to the high lipid composition of mitochondria and the generation of a large negative membrane potential (relative to the cellular cytoplasm) for oxidative phosphorylation. Results presented for NPHB of MF680 located in the cells show significant differences between the two cell lines. The ...

2002-08-01

174

Rapid yield learning through optical defect and electrical test analysis  

Energy Technology Data Exchange (ETDEWEB)

As semiconductor device density and wafer area continue to increase, the volume of in-line and off-line data required to diagnose yield-limiting conditions is growing exponentially. To manage this data in the future, analysis tools will be required that can automatically reduce this data to useful information, e.g., by assisting the engineer in rapid root-cause diagnosis of defect generating mechanisms. In this paper, the authors describe a technology known as Spatial Signature Analysis (SSA) and its application to both optically-detected defect data as well as electrical test (e-test) bin data. The results of a validation study are summarized that demonstrate the effectiveness of the SSA approach on optical defect wafermaps through field-testing at three semiconductor manufacturing sites on ASIC, DRAM and SRAM products. This method has been extended to analyze and interpret electrical test data and to provide a pathway for correlation of this data with in-line optical measurements. ...

1998-02-01

175

Patterns of proliferation related to vasculature in human head-and-neck carcinomas before and after transplantation in nude mice  

International Nuclear Information System (INIS)

Purpose: The predictive potential of tumor cell kinetic parameters may be improved when they are studied in relation to other microenvironmental parameters. The purpose of this investigation was to quantitatively categorize human tumor samples according to proliferation patterns. Second, it was examined whether these characteristics are retained after xenotransplantation. Methods and Materials: Fifty tumor samples from head-and-neck cancer patients were immunohistochemically stained for Ki-67 and vessels. Also, parts of the samples were transplanted into nude mice. Tumors were categorized according to previously described patterns of proliferation. Vascular and proliferation patterns were analyzed using an image processing system. Results: The 50 tumors were categorized into four patterns of proliferation by visual assessment: marginal (6), intermediate (10), random (21), and mixed (12). One tumor could not be classified. These patterns were ...

2001-12-01

176

Comparison of gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for enhanced MR imaging of brain and spine tumours in children  

International Nuclear Information System (INIS)

Sixty-three subjects, aged 6 months to 16 years, who were enrolled in a prospective, fully blinded, randomized parallel-group phase III clinical trial, received 0.1 mmol/kg doses of either Gd-BOPTA (n=29) or Gd-DTPA (n=34). The MR images were acquired before and within 10 min of contrast agent injection. The primary objective was to compare the difference from pre-dose to post-dose lesion visualization between Gd-BOPTA and Gd-DTPA. Lesion visualization was determined as the sum of individual scores for three criteria of lesion morphological characteristics (lesion border delineation, internal morphology, and contrast enhancement), each assessed qualitatively using 4-point scales. Quantitative evaluation compared changes in lesion-to-background (LBR) and contrast-to-noise (CNR) ratios and per cent enhancement. Monitoring for adverse events and evaluation of vital signs and laboratory values was performed. Pre-dose to post-dose changes in lesion ...

2005-05-01

177

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features; Modificazioni anatomiche dopo chirurgia radicale e ricostruzione con lembi peduncolati o rivascolarizzati nei tumori cervico-facciali negli stadi avanzati: Aspetti con Tomografia Computerizzata e Risonanza Magnetica  

Energy Technology Data Exchange (ETDEWEB)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial flaps appeared as mostly fatty thickened ...

1997-04-01

178

Anatomical changes after radical surgery and reconstruction with pedunculated or revascularized flaps in advanced head and neck cancer: CT and MR features  

International Nuclear Information System (INIS)

January, 1992, to October, 1995, sixty-four patients with advanced head and neck cancer underwent head and neck reconstructive surgery using myocutaneous or revascularized flaps; in the same period, all patients were consecutively examined with CT and MRI. Myocutaneous flaps were used in 26 patients: 12 flaps were tubular and 14 linear. Revascularized flaps were used in 38 patients: to repair a large defect in 26 patients (14 latissimus dorsi flaps and 12 temporal muscle flaps) and to repair an oral damage in 12 patients (5 revascularized radial and 7 jejunal flaps). CT and MR images of myocutaneous flaps showed the flaps as fatty areas, repairing large surgical defects, hypodense at CT and hyperintense at MRI, with no post-contrast enhancement. The appearance of revascularized flaps at CT and MRI depends on the characteristics of the structure used to repair the surgical defect: jejunal and radial flaps appeared as mostly fatty thickened ...

1997-01-01

179

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-07-01

180

Radioisotope imaging of brain tumors in two rhesus monkeys. Final report  

Energy Technology Data Exchange (ETDEWEB)

Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.

1988-04-01

181

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

182

Fracture imaging with converted elastic waves  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

2001-05-29

183

[Retrieval of spectral characteristics of hyperspectral sensor and retrieval of reflectance spectra].  

Science.gov (United States)

On-orbit spectral calibration of hyperspectral imaging data is a key step for quantitatively analyzing them. Like the atmospheric correction, accurate spectral calibration is very necessary for improved studies of land or ocean surface properties. Based on the previous literatures, a new method which coupled an optimization algorithm was developed to simultaneously retrieve the central wavelength and the full width at half maximum (FWHM) of the hyperspectral sensor without needing the in situ reflectance spectra. Firstly, the Hyperion data set simulated using MODTRAN4 with the Hyperion spectral specification was used to test the new method, and the results indicated that the maximum error was less than 0.1 and 0.7 nm for central wavelength and FWHM respectively when the spectral shift is 5 nm. Then the algorithm was applied to the Hyperion data acquired on May 20, 2008 over Heihe River Basin and it was iteratively performed for each detector of the two ...

2010-10-01

184

Three-phase flow in heterogeneous wettability porous media; Deplacements triphasiques en milieux poreux de mouillabilite heterogene  

Energy Technology Data Exchange (ETDEWEB)

Better understanding and modelling of three-phase flow through porous media is of great interest, especially for improved oil recovery methods such as gas injection processes. Early theoretical and experimental studies have already demonstrated that the wettability characteristics of the solid surface and the spreading characteristics of the fluid system hold the key roles. This observation is confirmed by our theoretical results using DLP theory on the stability and the thickness of static oil films. In most of the works related to three-phase flow processes, homogeneous wettability is assumed. There exist only a few studies demonstrating the tremendous impact of the wettability heterogeneities on gas injection. The objective of the present work is twofold: to demonstrate the effect of small scale wettability heterogeneities on gas injection efficiency, and to develop a tool to predict this impact for various patterns and spatial ...

1998-11-26

185

Developments of PET radioligands for NMDA receptors  

International Nuclear Information System (INIS)

Aim: There has been a great demand for developments of the radioligands to visualize the N-methyl-D-aspartate (NMDA) receptors by PET/SPECT. We have recently synthesized two C-11 labeled antagonists for the glycine-binding site on NMDA receptors. The aim of this work is to examine for their in vitro and in vivo binding characteristics, and to evaluate their potentials as PET radioligands for the NMDA receptors. Materials and methods: Two C-11 labeled 4-hydroxy-2-quinolones (1 and 2) were synthesized by conventional methylation of the corresponding phenols with ["1"1C]methyl iodide. In vitro and ex vivo quantitative autoradiographs with imaging plate, as well as animal PET, were employed in order to evaluate their in vitro and in vivo binding to the NMDA receptors. Results: The compound 1 showed the specific binding to rat brain slices with higher localization in the hippocampus and cerebral cortex than in the cerebellum. Both glycine ...

2002-09-01

186

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...

1992-01-01

202

The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries  

UK PubMed Central (United Kingdom)

The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available

2010-01-01

203

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

204

Radionuclide imaging of the acutely painful scrotum  

International Nuclear Information System (INIS)

This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.

205

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

206

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

207

Nonnegative Factorization of Diffusion Tensor Images and Its Applications  

UK PubMed Central (United Kingdom)

This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available

2011-01-01

208

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

209

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

210

Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging  

UK PubMed Central (United Kingdom)

Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available

2010-09-01

211

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

212

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

213

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

214

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

215

Comprehensive Quantification of Signal-to-Noise Ratio and g-Factor for Image-Based and k-Space-Based Parallel Imaging Reconstructions  

UK PubMed Central (United Kingdom)

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available

2008-10-01

216

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...

2007-09-21

217

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

218

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-01-01

219

An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available

2010-07-01

220

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

221

Operational Characteristics of a Liquid Nitrogen Powered ...  

Science.gov (United States)

... Accession Number : ADA350829. Title : Operational Characteristics of a Liquid Nitrogen Powered Automobile. Descriptive Note : Master's thesis. ...

1998-08-04

222

Characteristics of the Mechanical Properties and the Fractures ...  

Science.gov (United States)

... Accession Number : ADA136144. Title : Characteristics of the Mechanical Properties and the Fractures of an Alpha Beta Titanium Alloy,. ...

1983-11-18

223

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

224

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

225

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

226

Typhoon Aere : Image of the Day - NASA Earth Observatory  

Science.gov (United States)

Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...

227

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

228

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

229

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

230

JHK and 3.3um PAH Imaging of the Starburst Ring in the Type I Seyfert Galaxy NGC 7469  

Science.gov (United States)

Imaging of NGC 7469 in the J, H, & K bands shows that the starburst 'ring' is a tight inner

1993-01-01

231

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

232

Imaging subsurface using cross-correlation  

Energy Technology Data Exchange (ETDEWEB)

This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.

1997-12-31

233

Image Analysis and Computer Vision: 1996.  

Science.gov (United States)

... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...

1997-01-01

234

Histopathological Image Analysis: A Review  

UK PubMed Central (United Kingdom)

Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available

2009-01-01

235

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a ...

2002-03-01

236

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...

2001-01-01

237

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...

2001-10-01

238

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...

239

Visible Earth: Typhoon Aere  

Science.gov (United States)

NASA's Visible Earth catalog of NASA images and animations of our home planet.

241

Theoretical study of subwavelength imaging by acoustic metamaterial slabs  

CERN Document Server

We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.

2009-01-01

245

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

250

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

252

Lead-203 for skeletal imaging  

International Nuclear Information System (INIS)

... biological variability body distribution kidneys labelled compounds lead 203

253

Knowledge-based image analysis: some aspects on the analysis of images using other types of information  

Energy Technology Data Exchange (ETDEWEB)

The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.

1982-01-01

255

Introduction to Three Dimensional Reconstruction of Brain C. T. Image  

International Nuclear Information System (INIS)

The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.

1986-11-01

263

Fundamental study on Fuji Computed Radiography (FCR) image  

International Nuclear Information System (INIS)

Japanese (Mar 1986). Japan Tomiyoshi, Tsukasa Kakoi, Iwao Fukushima,

1986-01-01

266

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

278

A submillimeter wavelength space-based imaging radar  

Science.gov (United States)

This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.

1988-05-01

280

In vitro MRI of brain development  

International Nuclear Information System (INIS)

In this review, we demonstrate the developmental appearance, structural features, and reorganization of transient cerebral zones and structures in the human fetal brain using a correlative histological and MRI analysis. The analysis of postmortem aldehyde-fixed specimens (age range: 10 postovulatory weeks to term) revealed that, at 10 postovulatory weeks, the cerebral wall already has a trilaminar appearance and consists of: (1) a ventricular zone of high cell-packing density; (2) an intermediate zone; (3) the cortical plate (in a stage of primary consolidation) with high MRI signal intensity. The anlage of the hippocampus is present as a prominent bulging in the thin limbic telencephalon. The early fetal telencephalon impar also contains the first commissural fibers and fornix bundles in the septal area. The ganglionic eminence is clearly visible as an expanded continuation of the proliferative ventricular zone. The basal ganglia showed an initial aggregation of cells. The most ...

2006-02-01

281

Characterization of [[sup 123]I]IDAM as a novel single-photon emission tomography tracer for serotonin transporters  

Energy Technology Data Exchange (ETDEWEB)

Development of selective serotonin transporter (SERT) tracers for single-photon emission tomography (SPET) is important for studying the underlying pharmacology and interaction of specific serotonin reuptake site inhibitors, commonly used antidepressants, at the SERT sites in the human brain. In search of a new tracer for imaging SERT, IDAM (5-iodo-2-[[2-2-[(dimethylamino)methyl]phenyl]thio]benzyl alcohol) was developed. In vitro characterization of IDAM was carried out with binding studies in cell lines and rat tissue homogenates. In vivo binding of [[sup 125]I]IDAM was evaluated in rats by comparing the uptakes in different brain regions through tissue dissections and ex vivo autoradiography. In vitro binding study showed that IDAM displayed an excellent affinity to SERT sites (K[sub i]=0.097 nM, using membrane preparations of LLC-PK[sub 1] cells expressing the specific transporter) and showed more than 1000-fold of selectivity for SERT over norepinehrine and ...

1999-08-01

282

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

283

Utilization of fractional Brownian motion in constrained least-squares restoration of medical images  

International Nuclear Information System (INIS)

Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.

284

Document image retrieval with morphology-based segmentation and features combination  

Science.gov (United States)

Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...

2011-01-01

285

Comparative evaluation of /sup 99m/Tc GH, /sup 99m/TcO_4, and /sup 99m/Tc DTPA as brain imaging agents  

International Nuclear Information System (INIS)

The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.

286

Subsurface imaging using the spectral polarization difference technique and NIR illumination  

Energy Technology Data Exchange (ETDEWEB)

A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.

1999-01-26

287

Cutaneous gallium uptake in patients with AIDS with mycobacterium avium-intracellulare septicemia  

International Nuclear Information System (INIS)

Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.

288

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity; Moderne bildgebende Methoden bei der Diagnostik von Tumoren des Oropharynx und der Mundhoehle  

Energy Technology Data Exchange (ETDEWEB)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement ...

1996-11-01

289

Diagnostic value of apparent diffusion coefficient value in prediction of grade for neuroepithelial tumors  

International Nuclear Information System (INIS)

Objective: To investigate the predictive value of ADC value in grading of neuroepithelial tumors. Methods: The clinical data and images of 70 patients with neuroepithelial tumors pathologically proven were collected and analyzed retrospectively. All the patients were classified into low (WHO I or II) and high (WHO III or IV) grade groups which included 40 and 30 cases respectively according to the 2007 WHO classification of tumours of the central nervous system. All the patients underwent plain and contrast-enhanced MR scan and DWI before surgery. The minimum ADC (MinADC) value was measured postoperatively on ADC maps. The Ki-67 labeling index (Ki-67 LI) of tumor tissue was determined by immunohistochemistry. MinADC values for two groups were analyzed using student t test, while the age and Ki-67 LI for the two groups was analyzed using Mann-Whitney test (P<0.05 considered to be significant). Also the MinADC value and Ki-67 LI were analyzed with Pearson ...

2009-11-01

290

Myocardial imaging in patients with Kawasaki disease. Exercise stress imaging and serial studies  

Energy Technology Data Exchange (ETDEWEB)

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...

1982-06-01

291

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.  

Science.gov (United States)

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...

2003-01-01

292

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...

2006-08-01

293

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

294

Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image  

Energy Technology Data Exchange (ETDEWEB)

In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...

1985-01-01

295

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...

1993-12-01

296

Direct digital radiography vs conventional radiography of thoracic spine: a comparative study  

International Nuclear Information System (INIS)

Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...

2005-09-01

297

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...

2008-12-15

298

Understanding and predicting soot generation in turbulent non-premixed jet flames.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the results of a project funded by DoD's Strategic Environmental Research and Development Program (SERDP) on the science behind development of predictive models for soot emission from gas turbine engines. Measurements of soot formation were performed in laminar flat premixed flames and turbulent non-premixed jet flames at 1 atm pressure and in turbulent liquid spray flames under representative conditions for takeoff in a gas turbine engine. The laminar flames and open jet flames used both ethylene and a prevaporized JP-8 surrogate fuel composed of n-dodecane and m-xylene. The pressurized turbulent jet flame measurements used the JP-8 surrogate fuel and compared its combustion and sooting characteristics to a world-average JP-8 fuel sample. The pressurized jet flame measurements demonstrated that the surrogate was representative of JP-8, with a somewhat higher tendency to soot formation. The premixed flame measurements revealed that ...

2010-10-01

299

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection rates were obtained for the three X-ray filter sets, although ...

1994-10-01

300

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection rates were obtained for the three X-ray filter sets, although ...

1994-01-01

301

Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol; Indicacion de las tecnicas de diagnostico por la imagen en la sospecha de apendicitis aguda: propuesta de protocolo diagnostico  

Energy Technology Data Exchange (ETDEWEB)

To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer ...

2001-07-01

302

Enzyme-induced growth of silver nanoparticles studied on single particle level  

Energy Technology Data Exchange (ETDEWEB)

Based on their interesting properties, metal nanoparticles show the potential as an analytical tool in electronic (Burmeister et al. 2004), optical (Yguerabide and Yguerabide 1998), and catalytic applications (Liu 2006). Their characteristics depend on the composition, shape, and size of the single particles. These various properties are utilized in many different approaches such as optics, magnetics (Lang et al. 2007), and laser technology (Csaki et al. 2007). We investigated an alternative method for the synthesis of nanoparticles. In this case, an enzyme, horseradish peroxidase, induces a silver deposition and replaces a metal nanoparticle as the reaction seed. Depending on the reaction time, we could obtain particles in a range of few nanometers up to more than 250 nm. For a better understanding of the enzymatic silver deposition process, the silver particles produced by this process were analyzed by SEM, TEM, and atomic force microscopy (AFM) on a single ...

2009-05-15

303

Durability of cement-based materials: modeling of the influence of physical and chemical equilibria on the microstructure and the residual mechanical properties; Durabilite des materiaux cimentaires: modelisation de l'influence des equilibres physico-chimiques sur la microstructure et les proprietes mecaniques residuelles  

Energy Technology Data Exchange (ETDEWEB)

A large part of mechanical and durability characteristics of cement-based materials comes from the performances of the hydrated cement, cohesive matrix surrounding the granular skeleton. Experimental studies, in situ or in laboratory, associated to models, have notably enhanced knowledge on the cement material and led to adapted formulations to specific applications or particularly aggressive environments. Nevertheless, these models, developed for precise cases, do not permit to specifically conclude for other experimental conclusions. To extend its applicability domain, we propose a new evolutive approach, based on reactive transport expressed at the microstructure scale of the cement. In a general point of view, the evolution of the solid compounds of the cement matrix, by dissolutions or precipitations, during chemical aggressions can be related to the pore solution evolution, and this one relied to the ionic exchanges with the external environment. By the ...

2004-09-15

304

Development of methodics for the characterization of the composition of the ion-collision-induced secondary-particle flux by comparison of the yield contributions of photoinduced ion formation processes; Entwicklung einer Methodik zur Charakterisierung der Zusammensetzung des ionenbeschussinduzierten Sekundaerteilchenflusses durch Vergleich der Ausbeuteanteile photoinduzierter Ionenbildungsprozesse  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work was to develop a method to distinguish between different ion formation processes and to determine the influence of these processes on the total number of detected monatomic ions of a certain element. A vector/matrix-formalism was developed, which describes the physical processes of sputtering, ion formation, mass separation and detection in laser-SNMS. In the framework of the method developed, based on this theoretic formalism, changes in the secondary flux contribution of the respective element were observed by comparing the detected monatomic ion yield obtained in specifically aligned (SIMS and) laser-SNMS experiments. The yields resulting from these experiments were used to calculate characteristic numbers to compare the flux composition from different surfaces. The potential of the method was demonstrated for the elements boron, iron and gadolinium by investigating the changes in the flux composition of secondary particles sputtered from ...

2008-10-13

305

Appendix W: deep sea biophysics (microbiology and amphiped studies)  

International Nuclear Information System (INIS)

CNPT-3 is the laboratory designation of a strain of bacteria that reproduces best at deep-sea pressures. It was isolated from a sample collected at a 5800 m depth of the Pacific Ocean. This isolation was achieved from a sample that had been retrieved without warning. This year we demonstrated that there are similarly behaving bacteria that can be isolated from samples even when retrieved with decompression. The purpose of this project was to define the temperatures and pressures over which CNPT-3 can exist and function. (1) At 2"0C CNPT-3 is eurybathic from about 1000 to 6500 m, as judged from an only slightly pressure dependent generation time. (2) CNPT-3 is unquestionably barophilic at 2"0C, with doubling times of 9 hours at 580 bars and over 18 hours at 1 bar. (3) At 10"0C, reproduction is adversely affected at 1 bar to the extent that CNPT-3 becomes obligately barophilic at 10"0C. Yet reproduction is enhanced above 280 bars and occurs with a regeneration time of 4 hours at 690 bars ...

1981-04-01

306

One-particle characteristics in problems with allowance for complex configurations  

Energy Technology Data Exchange (ETDEWEB)

A method for the determination of different ''bare'' characteristics of the one-particle motion and one-particle basis in magic nuclei is described. The method is based on separating out the mixing with phonons from the phenomenological one-particle characteristics. By means of a generalization of the procedure for localization of the mass operator, relations linking the bare and phenomenological characteristics are obtained. The radial dependence of these characteristics in finite nuclei and the influence of the quasiparticle--phonon interaction on the phenomenological characteristics are studied. Calculations are performed for the neutrons in /sup 208/Pb.

1986-09-01

307

Workability and Heat Treatment Characteristics of Beta ...  

Science.gov (United States)

... Accession Number : ADD135317. Title : Workability and Heat Treatment Characteristics of Beta Titanium Alloy, Ti-15V-3Cr-3Sn-3Al,. ...

1986-04-01

308

TECHNICAL REPORT - NASA Technical Reports Server  

Science.gov (United States)

VORTEX VALVE FLOW CHARACTERISTICS. 49. VENTED VORTEX VALVE. 50. VORTEX DIVERTER VALVE- ... 46 AND VORTEX MIXING VALVE FLOW CHARACTERISTICS ...

309

Social, Clinical and Microbiological Differential Characteristics of Tuberculosis among Immigrants in Spain  

UK PubMed Central (United Kingdom)

BackgroundTo identify the differential tuberculosis (TB) characteristics within the immigrant population with respect to natives in Spain.Methodology/Principal...Full Text Available

310

Pressure loss coefficients for staggered multiorifice/shield plates  

Science.gov (United States)

The hydraulic characteristics of flow control multiorifice plate assemblies designed for the FFTF reactor were investigated. The pressure drop flowrate characteristics determined in the test are presented. (JWR)

1973-10-01

311

Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability  

CERN Document Server

Industrial-process control valves Part2 : Flow capacity Section Four : Inherent flow characteristics and rangeability

1989-01-01

312

Clinical Characteristics and Outcomes of Cataract Surgery in Highly Myopic Koreans  

UK PubMed Central (United Kingdom)

PurposeTo evaluate the clinical characteristics and outcomes of cataract surgery in highly myopic Korean subjects.MethodsWe retrospectively reviewed...Full Text Available

2011-04-01

313

//s /~7 - NASA CR-  

Science.gov (United States)

Valve Flow Characteristics. 3-68. 3-40. Valve Operating Current Vs. Temperature ...... VALVE FLOW CHARACTERISTICS. Acceptance Test 4/29/74. SINs 002 & 004 ...

314

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

315

Tracheal images using energy subtraction Fuji computed radiography  

International Nuclear Information System (INIS)

Twenty patients with lesions in the trachea or bronchus underwent energy subtraction Fuji computed radiography (FCR). Images obtained were compared with those from conventional FCR (plain FCR). ''Very clear'' images (in which the contour of the trachea and bronchus could be clearly defined) were obtained in 12/22 (55 %) by energy subtraction FCR and in 3/22 (14 %) by plain FCR; ''clear'' images (in which the contour could be defined) in 9/22 (41 %) by energy subtraction FCR and in 18/22 (82 %) by plain FCR; and ''unclear'' images (in which the contour could not be defined) in 1/22 (5 %) by both methods. Energy subtraction FCR, as well as plain FCR, yielded high image quality for the trachea. Energy subtraction FCR was superior to plain films when tumors existed within the trachea. (Namekawa, K.).

1985-01-01

316

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

317

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

318

Parallel architecture for rapid image generation and analysis  

Energy Technology Data Exchange (ETDEWEB)

A multiprocessor architecture inspired by the Disney multiplane camera is proposed. For many applications, this approach produces a natural mapping of processors to objects in a scene. Such a mapping promotes parallelism and reduces the hidden-surface work with minimal interprocessor communication and low-overhead cost. Existing graphics architectures store the final picture as a monolithic entity. The architecture here stores each object's image separately. It assembles the final composite picture from component images only when the video display needs to be refreshed. This organization simplifies the work required to animate moving objects that occlude other objects. In addition, the architecture has multiple processors that generate the component images in parallel. This further shortens the time needed to create a composite picture. In addition to generating images for animation, the ...

1987-01-01

319

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

320

Magnetization transfer contrast effect on multislice fast spin echo  

Energy Technology Data Exchange (ETDEWEB)

Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).

1994-03-01

321

Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach  

British Library Electronic Table of Contents (United Kingdom)

This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...

2009-01-01

322

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

323

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more ...

2007-08-21

324

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of ...

2007-08-21

325

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best ...

1991-12-01

326

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical ...

1991-01-01

327

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-08-01

328

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-01-01

329

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

330

X-Ray Phase Imaging for Breast Cancer Detection  

Science.gov (United States)

... Accession Number : ADA535309. Title : X-Ray Phase Imaging for Breast Cancer Detection. Descriptive Note : Annual rept. 1 Sep 2009-31 Aug 2010 ...

2010-09-01

331

Volume 2- Technical Approach - IMAGE Science Center - NASA  

Science.gov (United States)

Power system analysis shows the output from the solar arrays varies as a function .... Each array corresponds to a raw image browse product, which is generated by .... low outgassing, ability to withstand long-term exposure to the space ...

332

Verification of MLC based real-time tumor tracking using an electronic portal imaging device  

UK PubMed Central (United Kingdom)

Purpose: The authors have developed a novel technique using an electronic portal imaging device (EPID) to verify the geometrical accuracy of delivery of dose-rate-regulated tracking (DRRT)....Full Text Available

2010-06-01

333

Technical note: A physical phantom for assessment of accuracy of deformable alignment algorithms  

International Nuclear Information System (INIS)

The purpose of this study was to investigate the feasibility of a simple deformable phantom as a QA tool for testing and validation of deformable image registration algorithms. A diagnostic thoracic imaging phantom with a deformable foam insert was used in this study. Small plastic markers were distributed through the foam to create a lattice with a measurable deformation as the ground truth data for all comparisons. The foam was compressed in the superior-inferior direction using a one-dimensional drive stage pushing a flat 'diaphragm' to create deformations similar to those from inhale and exhale states. Images were acquired at different compressions of the foam and the location of every marker was manually identified on each image volume to establish a known deformation field with a known accuracy. The markers were removed digitally from corresponding images prior to ...

2007-07-01

334

TLD assessment of mouse dosimetry during microCT imaging  

UK PubMed Central (United Kingdom)

Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high...Full Text Available

2008-09-01

335

Subject-specific, multiscale simulation of electrophysiology: a software pipeline for image-based models and application examples  

UK PubMed Central (United Kingdom)

Many simulation studies in biomedicine are based on a similar sequence of processing steps, starting from images and running through geometric model generation, assignment of tissue properties, numerical...Full Text Available

2009-06-13

336

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

337

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

Energy Technology Data Exchange (ETDEWEB)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...

1987-03-01

338

Single exposure energy subtraction chest radiography in the diagnosis of pulmonary cancer  

International Nuclear Information System (INIS)

A single exposure energy subtraction technique with a metal filter and an imaging plate for the Fuji Computed Radiography (FCR) system was developed for dual-energy subtraction radiography (DES) of the chest. By the use of this technique, 206 patients with suspected lung cancer were scanned in the clinical settings. The subtracted images in 200 patients, excluding six with poor image quality, were examined. Soft-tissue images (bone cancelled images) were useful in visualizing abnormality of the airway and nodules lying under the ribs; and bone images (soft-tissue cancelled images) in detecting rib metastases and the presence or absence of calcification in nodules. Additional information was acquired in 21 % (42/200). A single exposure is capable of neglecting motion artifacts. In addition, this technique may be of value in DES, which is ...

1987-01-01

339

Simple device for scanning image  

CERN Document Server

The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.

2002-01-01

340

Signal and imaging sciences workshop proceedings  

Energy Technology Data Exchange (ETDEWEB)

Papers are presented in the areas of: Medical Technologies; Non-Destructive Evaluation; Applications of Signal/Image Processing; Laser Guide Star and Adaptive Optics; Computational Electromagnetic, Acoustics and Optics; Micro-Impulse Radar Processing; Optical Applications; TANGO Space Shuttle.

1997-11-01

341

SEGMENTING CT PROSTATE IMAGES USING POPULATION AND PATIENT-SPECIFIC STATISTICS FOR RADIOTHERAPY  

UK PubMed Central (United Kingdom)

This paper presents a new deformable model using both population and patient-specific statistics to segment the prostate from CT images. There are two novelties in the proposed method. First,...Full Text Available

2009-08-07

342

Romantic and Sexual Relationships, Body Image, and Fertility in Adolescent and Young Adult Testicular Cancer Survivors: A Review of the Literature  

UK PubMed Central (United Kingdom)

This review presents a summary of existing knowledge regarding the impact of testicular cancer along four broad domains, including romantic and sexual relationships, body image, and fertility....Full Text Available

2010-08-01

343

Retinal Fundus Image Registration via Vascular Structure Graph Matching  

UK PubMed Central (United Kingdom)

Motivated by the observation that a retinal fundus image may contain some unique geometric structures within its vascular trees which can be utilized for feature matching, in this paper, we proposed...Full Text Available

2010-01-01

344

Real-Time Assessment of Cardiac Perfusion, Coronary Angiography, and Acute Intravascular Thrombi Using Dual-Channel Near-Infrared Fluorescence Imaging  

UK PubMed Central (United Kingdom)

ObjectivesWe have developed an image-guided surgery system based on invisible near-infrared (NIR) fluorescent light. Presently, the only clinically-available NIR...Full Text Available

2009-07-01

345

Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems  

UK PubMed Central (United Kingdom)

Currently several groups are actively researching the integration of a megavoltage teletherapy unit with magnetic resonance (MR) imaging for real-time image-guided radiotherapy. The use of a...Full Text Available

2010-02-21

346

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

347

Noise Characterization of Polycrystalline Silicon Thin Film Transistors for X-ray Imagers Based on Active Pixel Architectures  

UK PubMed Central (United Kingdom)

An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available

2008-01-01

348

New real-time MR image-guided surgical robotic system for minimally invasive precision surgery  

Energy Technology Data Exchange (ETDEWEB)

To investigate the usefulness of a newly developed magnetic resonance (MR) image-guided surgical robotic system for minimally invasive laparoscopic surgery. The system consists of MR image guidance [interactive scan control (ISC) imaging, three-dimensional (3-D) navigation, and preoperative planning], an MR-compatible operating table, and an MR-compatible master-slave surgical manipulator that can enter the MR gantry. Using this system, we performed in vivo experiments with MR image-guided laparoscopic puncture on three pigs. We used a mimic tumor made of agarose gel and with a diameter of approximately 2 cm. All procedures were successfully performed. The operator only advanced the probe along the guidance device of the manipulator, which was adjusted on the basis of the preoperative plan, and punctured the target while maintaining the operative field using robotic forceps. The position of the probe ...

2008-04-15

349

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

350

Multi-focal optical-resolution photoacoustic microscopy in vivo  

UK PubMed Central (United Kingdom)

Although ultrasound arrays were exploited in photoacoustic imaging to improve imaging speed, ultrasound-array-based optical-resolution photoacoustic microscopy (OR-PAM) has never been achieved...Full Text Available

2011-04-01

351

Monitoring of NK-Cell Immunotherapy using non-invasive Imaging Modalities  

UK PubMed Central (United Kingdom)

Cancer immunotherapies can be guided by cellular imaging techniques, which can identify the presence or absence of immune-cell accumulation in the tumor tissue in-vivo and in real time. This...Full Text Available

2010-08-01

352

Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To define a method for measurement of the cross sectional area and volume of the quadriceps femoris muscle using magnetic resonance imaging (MRI) in conjunction with stereology, and to compare...Full Text Available

1997-03-01

353

JAtlasView: a Java atlas-viewer for browsing biomedical 3D images and atlases  

UK PubMed Central (United Kingdom)

BackgroundMany three-dimensional (3D) images are routinely collected in biomedical research and a number of digital atlases with associated anatomical and other information have...Full Text Available

354

In vivo imaging of neutrotransmitter functions in brain, heart and tumors  

Energy Technology Data Exchange (ETDEWEB)

This volume contains the proceedings of a symposium entitled In Vivo Imaging of Neurotransmitter Function in Brain, Heart, and Tumors'' held August 24--25, 1990 in Montreal Canada. The six individual papers contained herein are separately abstracted and indexed for the database.

1991-01-01

355

Human Lymphatic Architecture and Dynamic Transport Imaged Using Near-infrared Fluorescence12  

UK PubMed Central (United Kingdom)

BACKGROUND: Although the importance of lymphatic function is well recognized, the lack of real-time imaging modalities limits our understanding of its role in many diseases. In a phase...Full Text Available

356

High Contrast Near-infrared Polarized Reflectance Images of Demineralization on Tooth Buccal and Occlusal Surfaces at ?=1310-nm  

UK PubMed Central (United Kingdom)

Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available

2009-03-01

357

Exploration of exposure dose optimization for pelvic examination in direct digital radiography with a phantom  

International Nuclear Information System (INIS)

Objective: To investigate the relationship between exposure dose and image quality for a direct digital radiography system and to determine the optimum exposure parameters for pelvic examination. Methods: A contrast-detail phantom CDRAD2.0 was exposed to different doses and the IQF of phantom images were calculated. The optimum exposure parameters were determined by ANOVA and SNK analysis. The image of an anthropomorphic phantom taken with optimized exposure parameters was verified using CEC image criteria. Results: The IQF of the images of CDRAD2.0 phantom was significantly different for different doses, as the exposure dose was greater than 0.61 mGy. The IQFs have no difference for different dose groups. The image quality between this optimized exposure dose and conventional exposure dose not was significantly different. Conclusion: The ...

2005-10-01

358

Evaluation of Tumor Micro-Environment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging  

UK PubMed Central (United Kingdom)

RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available

2011-01-01

359

Early detection of bone metastases of Ewing's sarcoma by magnetic resonance imaging  

International Nuclear Information System (INIS)

Bone metastases of an Ewing's sarcoma were detected by magnetic resonance imaging (MRI), when bone scan, CT and plain films were still normal. This is due to the ability of MRI to detect intramedullary metastases before involvement of the cortex. (Auth.).

360

Early Detection of Bronchial Lesions Using Lung Imaging Fluorescence Endoscope  

UK PubMed Central (United Kingdom)

The performance of the Lung Imaging Fluorescence Endoscope (LIFE) system was compared with conventional bronchoscopy in 158 patients: 68 patients with invasive cancer, 42 patients with abnormal sputum...Full Text Available

1999-01-01

361

Dual-channel imaging system for singlet oxygen and photosensitizer for PDT  

UK PubMed Central (United Kingdom)

A two-channel optical system has been developed to provide spatially resolved simultaneous imaging of singlet molecular oxygen (1O2) phosphorescence and photosensitizer (PS) fluorescence...Full Text Available

362

Doppler imaging using spectrally-encoded endoscopy  

UK PubMed Central (United Kingdom)

The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available

2008-09-15

363

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

Energy Technology Data Exchange (ETDEWEB)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-09-01

364

Digital image precessing for neutron television fluoroscopic system and its application to neutron computed tomography  

International Nuclear Information System (INIS)

The real-time neutron radiography system of the Kyoto University Reactor (KUR) has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuels and to investigation of moving objects. Compared with the image obtained by the direct film method, however, the image from the TV system is in low-contrast and poor-resolution. This paper presents some digital processing approaches to improve the image quality and the neutron TV system is successfully applied to neutron computed tomography (NCT). The frame summing technique is effective to increase the quality of the radiographic image. By using the NTV system in NCT, the projection data are able to be acquired in a single measurement as observing the projection image on a CRT monitor. Two weighting functions based on the Fourier-convolution algorithm are employed to obtain the ...

1984-01-01

365

Design and Implementation of an Open Source Indexing Solution for a Large Set of Radiological Reports and Images  

UK PubMed Central (United Kingdom)

This paper hopes to share the insights we experienced during designing, building, and running an indexing solution for a large set of radiological reports and images in a production environment for...Full Text Available

2007-11-01

366

Correspondence of Ultrasound Elasticity Imaging to Direct Mechanical Measurement in Aging DVT in Rats  

UK PubMed Central (United Kingdom)

Previous ultrasound elasticity imaging experiments supported a generally accepted concept that the hardness of deep venous thrombi increases with thrombus aging. Results also showed that this...Full Text Available

2005-10-01

367

Closing the loop in cortically-coupled computer vision: a brain-computer interface for searching image databases.  

Science.gov (United States)

We describe a closed-loop brain-computer interface that re-ranks an image database by iterating between user generated 'interest' scores and computer vision generated visual similarity measures. The interest scores are based on decoding the electroencephalographic (EEG) correlates of target detection, attentional shifts and self-monitoring processes, which result from the user paying attention to target images interspersed in rapid serial visual presentation (RSVP) sequences. The highest scored images are passed to a semi-supervised computer vision system that reorganizes the image database accordingly, using a graph-based representation that captures visual similarity between images. The system can either query the user for more information, by adaptively resampling the database to create additional RSVP sequences, or it can converge to a 'done' state. The done state includes a ...

2011-05-12

368

Challenges of functional imaging research of pain in children  

UK PubMed Central (United Kingdom)

Functional imaging has revolutionized the neurosciences. In the pain field it has dramatically altered our understanding of how the brain undergoes significant functional, anatomical and chemical changes...Full Text Available

369

Automated 3-D method for the correction of axial artifacts in spectral-domain optical coherence tomography images  

UK PubMed Central (United Kingdom)

The 3-D spectral-domain optical coherence tomography (SD-OCT) images of the retina often do not reflect the true shape of the retina and are distorted differently along the x and y...Full Text Available

370

Antisense imaging of gene expression in the brain in vivo  

UK PubMed Central (United Kingdom)

Antisense radiopharmaceuticals could be used to image gene expression in the brain in vivo, should these polar molecules be made transportable through the blood–brain barrier....Full Text Available

2000-12-19

371

A high-speed network for cardiac image review.  

UK PubMed Central (United Kingdom)

A high-speed fiber-based network for the transmission and display of digitized full-motion cardiac images has been developed. Based on Asynchronous Transfer Mode (ATM), the network is scaleable, meaning...Full Text Available

1994-01-01

372

A comparison with result of normalized image to different template image on statistical parametric mapping of ADHD children patients  

Energy Technology Data Exchange (ETDEWEB)

We studied 64 ADHD children patients group (4 {approx} 15 ys, mean age: 8 {+-} 2.6 ys. M/F: 52/12) and 12 normal group (6 {approx} 7 ys, mean age: 9.4 {+-} 3.4 ys, M/F: 8/4) of the brain had been used to analysis of blood flow between normal and ADHD group. For analysis of Children ADHD, we used 12 children's mean brain images and made Template image of SPM99 program. In crease of blood flow (P-value 0.05), the result of normalized images to Template image to offer from SPM99 program, showed significant cluster in inter-Hemispheric and occipital Lobe, in the case of normalized images to children template image, showed inter-hemispheric and parietal lobe.

2003-06-15

373

A Software System for Data Analysis in Automated DNA?Sequencing  

UK PubMed Central (United Kingdom)

Software for gel image analysis and base-calling in fluorescence-based sequencing consisting of two primary programs, BaseFinder and GelImager, is described. BaseFinder is a framework for trace processing,...Full Text Available

1998-06-01

374

A Comparison of intra-oral digital imaging modalities: Charged Couple Device versus Storage Phosphor Plate  

UK PubMed Central (United Kingdom)

BackgroundThis in vitro study was conducted to compare the accuracy of two digital image receptors in identifying the location of tip of a fine endodontic file and radiographic apex...Full Text Available

2010-11-01

375

metadata, images and captions. - The Gateway to Astronaut ...  

Science.gov (United States)

... the Zaire is not an efficient transportation link because of many rapids and falls to negotiate between Kinshasa and the port city of Matadi. ...

376

Visible Earth: Food Additives  

Science.gov (United States)

Feb 25, 2008 ... NASA's Visible Earth catalog of NASA images and animations of our home planet.

377

Using Acoustic Tomography to Monitor Deep Ocean Currents ...  

Science.gov (United States)

... 2009. Copyright belongs to the Marine Technology Society., The original document contains color images. 14. ABSTRACT ...

2010-06-01

378

Tolerance limits of X-ray image intensity  

International Nuclear Information System (INIS)

Evaluation of the tolerance limits of X-ray image density accepted by the radiologist shows that for different kinds of examinations, deviations of more than 50% from optimal density lead to images which cannot be used diagnostically. Within this range diagnostic accuracy shows a distinct maximum and diminishes to the limits by 20%. These figures are related to differences in the intensifying factor of screens, sensitivity of films, sensitometric parameters of film processing as well as the doses employed with automatic exposure control devices, measured in clinical conditions. Maximum permissible tolerance limits of the whole imaging system and of its constituents are discussed using the Gaussian law of error addition. (author).

379

Three-dimensional image display of brain tumor utilizing a modified voxel method  

Energy Technology Data Exchange (ETDEWEB)

The patch and voxel methods are representative examples of the ways in which multi-slice images may be displayed three-dimensionally by means of computer-graphics. Each of them have advantages and disadvantages and they are mutually complementary. We have developed algorithms for a modified voxel method which incorporates the advantages of the patch methods. We have applied this to the three-dimensional image display of brain tumor with excellent results. The three-dimensional reconstructions used for clinical application in this study were derived from X-ray CT images.

1988-08-01

382

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...

384

Radiology of facial injury  

Energy Technology Data Exchange (ETDEWEB)

The authors present a guide to the imaging of facial fractures. It is illustrated with conventional radiographs and computed tomograms; the magnetic resonance images primarily suggest the potential applications of this technique. This book provides a source of imaging information on facial trauma. A section on pertinent anatomy is followed by a systematic discussion of the common isolated and complex facial fractures. Perspectives are offered on some commonly seen but infrequently described relationships, such as the tripod-LeFort II association. Consideration is also given to related soft-tissue injuries. The book includes a brief chapter on the type and utility of supplementary imaging studies in the evaluation of those intracranial injuries that may occur concurrently.

1988-01-01

385

Radioiodine benzodiazepines as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1992-03-17

386

Radioiodine benzodiazepines as brain imaging agents  

International Nuclear Information System (INIS)

This patent describes a radioiodinated benzodiazepine derivative. It comprises a lower alkyl group with 1-4 C-atoms and a radioactive iodine.

1990-06-25

387

RAPID DAMAGE ASSESSMENT FROM HIGH RESOLUTION IMAGERY  

Energy Technology Data Exchange (ETDEWEB)

Disaster impact modeling and analysis uses huge volumes of image data that are produced immediately following a natural or an anthropogenic disaster event. Rapid damage assessment is the key to time critical decision support in disaster management to better utilize available response resources and accelerate recovery and relief efforts. But exploiting huge volumes of high resolution image data for identifying damaged areas with robust consistency in near real time is a challenging task. In this paper, we present an automated image analysis technique to identify areas of structural damage from high resolution optical satellite data using features based on image content.

2008-07-01

388

Prospects for lithium imaging using annular bright field scanning transmission electron microscopy: A theoretical study  

British Library Electronic Table of Contents (United Kingdom)

There is strong interest in lithium imaging, particularly because of its significance in battery materials. However, light atoms only scatter electrons weakly and atomic resolution direct imaging of lithium has proven difficult. This paper explores theoretically the conditions under which lithium columns can be expected to be directly visible using annular bright field scanning transmission electron microscopy. A detailed discussion is given of the controllable parameters and the conditions most favourable for lithium imaging.

2011-01-01

391

Phase imaging using laser-produced X-ray sources  

International Nuclear Information System (INIS)

A possible novel application of hard x-ray emitted during laser-plasma interaction was discussed. The authors established an Optical Transform Function to study the joint effect of the spectral distribution and temporal profile of the laser-produced x-ray on x-ray phase imaging. Though the laser-produced x-ray pulse duration is short and incoherent, the analysis confirms that the current x-ray phase imaging theory still holds for laser-produced x-ray phase imaging

2000-08-01

392

Particle-Sizing System for Scanning Electron Microscope ...  

Science.gov (United States)

... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...

1991-03-01

393

Non-traumatic thoracic emergencies: imaging and treatment of thoracic fluid collections (including pneumothorax)  

International Nuclear Information System (INIS)

Cross-sectional imaging has revolutionised the radiological diagnosis of pleural collections. Not only can the precise location and volume of a pleural effusion be established, but also features specific for the aetiology of the effusion can be demonstrated. Increasingly, radiologists are called upon to perform image-guided biopsies, aspirations and small bore chest drain placement, all of which have been shown to be safe and efficacious. Pneumothoraces occurring due to acute trauma and in an intensive care setting can also benefit from radiological input, both in terms of diagnosis and image-guided treatment. (orig.)

2002-08-01

394

Monitoring the movement of water influx subsidence in coal district by remote sensing - examples from Huainan coal district  

Energy Technology Data Exchange (ETDEWEB)

Multitemporal TM images are used to collect information about the extension and variation of water influx subsidence in coal district in order to provide a reference for the harnessing and utilization of water influx subsidence. The multitemporal TM images are used as a blended data group for the analysis of the principal components to reflect the expanding water influx subsidence in the past years. Because of the differences in the environment and imaging condition, 'unitary' order is used to enhance the 'coherence' and 'comparability' of the original TM images. 5 refs., 4 figs., 2 tabs.

2002-08-01

395

MER-DIMES : a planetary landing application of computer vision  

Science.gov (United States)

During the Mars Exploration Rovers (MER) landings, the Descent Image Motion Estimation System

2005-01-01

398

Incidental discovery of asplenia syndrome, with situs inversus and a normal heart by radionuclide biliary imaging. A case report  

International Nuclear Information System (INIS)

/sup 99m/Tc biliary imaging was performed on a 34-year-old woman who was being investigated for suspected cholelithiasis. A left-sided liver was detected. On subsequent radionuclide imaging, partial visceral situs inversus and asplenia were demonstrated. Extensive roentgenographic investigation, ECG, echocardiogram, and laparotomy confirmed the radionuclide findings. Asplenia syndrome may exist without cardiovascular abnormalities and thus be undiscovered. Radionuclide imaging is important in the diagnosis of this syndrome.

399

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

400

Imaging findings of abdominal peripheral primitive neuroectodermal tumor: report of four cases with pathological correlation  

British Library Electronic Table of Contents (United Kingdom)

Peripheral primitive neuroectodermal tumors (peripheral PNETs) are rare in the abdomen. We report the imaging findings of four peripheral PNETs arising in the abdomen. Three were ill-demarcated tumors and one was a well-demarcated tumor, with extensive local invasion and lymph node metastasis in two cases, respectively. The tumors are of inhomogeneous attenuation and heterogeneous enhancement after intravenous administration of contrast materials. Although their imaging manifestations cannot distinguish them from other sarcomas, recognition of these imaging features may be helpful in suggesting the possibility of peripheral PNETs in some cases.

2009-01-01

401

Imaging characterization of carbon nanotube tips modified using a focused ion beam  

International Nuclear Information System (INIS)

A carbon nanotube (CNT) tip, which assembled on the sharp end of a Si tip by dielectrophoresis, was structurally modified using focused ion beam (FIB). We described the imaging characterization of the FIB-modified CNT tip in noncontact AFM mode in terms of wear, deep trench accessibility, and imaging resolution. Compared to a conventional Si tip, the FIB-modified CNT tip was superior, especially for prolonged scanning over 10 h. We conclude that modified CNT tips have the potential to obtain high-quality images of nanoscale structures.

2007-06-15

402

Image Descriptors for Displays  

Science.gov (United States)

... 44 2. Luminance Power Spectral Density Measurements ..... 44 ... 50 4. Chrominance Power Spectral Density Measurements ..... 53 ...

1977-02-01

403

Iao: The New Adaptive Optics Visible Imaging and ...  

Science.gov (United States)

... is the sensor that converts incoming photons into a ... with CCD foundries to acquire such a sensor. ... 2007, Journal of Spacecraft and Rockets, 44, 910 ...

2008-09-01

404

Growth, Characterization and Device Development in ...  

Science.gov (United States)

... eV. In some instances the spontaneous radiation from a free electron laser system was employed to obtain images. The ...

1998-03-01

406

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

407

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

408

Development of ARIES Baker-Nunn camera to a wide-field Imaging Telescope with CCD  

CERN Document Server

ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.

2009-01-01

409

Detection and Diagnosis of Oral Neoplasia with an Optical ...  

Science.gov (United States)

... Thus, 0CM provides the potential to image epithelial tissue with the subcellular resolution needed to assess the pathologic state of tissue. ...

410

DVRPC 2010 Digital Orthoimagery - Mr.SID County Mosaics  

Science.gov (United States)

... image overlap between adjacent tiles. Orthoimagery processed by BAE Systems....

411

Computer vision approaches to medical image analysis. Revised papers  

Energy Technology Data Exchange (ETDEWEB)

This book constitutes the thoroughly refereed post proceedings of the international workshop Computer Vision Approaches to Medical Image Analysis, CVAMIA 2006, held in Graz, Austria in May 2006 as a satellite event of the 9th European Conference on Computer Vision, EECV 2006. The 10 revised full papers and 11 revised poster papers presented together with 1 invited talk were carefully reviewed and selected from 38 submissions. The papers are organized in topical sections on clinical applications, image registration, image segmentation and analysis, and the poster session. (orig.)

2006-07-01

412

Cerebral angiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).

1985-01-01

413

Burned Timber Canyon  

Science.gov (United States)

The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid....

414

An Integrated Approach to Intelligent Systems  

Science.gov (United States)

... order probabilistic modelling, multisensor monitoring of ... object recognition, image registration and point ... of the Berkeley Continuous Media Toolkit. ...

2002-01-01

416

A Computer Vision System forAnalyzing Images of Rough Hardwood Lumber  

Science.gov (United States)

... In this paper research aimed at creating a computer vision system to power such an optimal edging and ... ...

466

A Description of the Management Characteristics of ...  

Science.gov (United States)

... Anesthetists (CCNA), and complies with criteria for biennial recertification (Jordan, 1994). The terms CRNAs and nurse ...

1998-10-01

467

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-11-01

468

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

International Nuclear Information System (INIS)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-01-01

469

Two-phase fluid flow measurements in small diameter channels using real-time neutron radiography  

International Nuclear Information System (INIS)

A series of real-time, neutron radiography, experiments are ongoing at the Texas A and M Nuclear Science Center Reactor (NSCR). These tests determine the resolving capabilities for radiographic imaging of two phase water and air flow regimes through small diameter flow channels. Though both film and video radiographic imaging is available, the real-time video imaging was selected to capture the dynamic flow patterns with results that continue to improve. (author)

1994-04-05

470

Thallium-technetium subtraction parathyroid imaging in patients having previous parathyroid surgery  

International Nuclear Information System (INIS)

Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck ...

1985-06-02

471

Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy  

International Nuclear Information System (INIS)

Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.

472

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

473

Quantitative phase imaging using hard x-rays  

International Nuclear Information System (INIS)

The quantitative imaging of a phase object using 16 keV x-rays is reported. The theoretical basis of the techniques is presented along with its implementation using a synchrotron x-ray source. It is found that the phase image is in quantitative agreement with independent measurements of the object. 13 refs., 5 figs.

2009-02-01

474

Quality control in Nuclear Magnetic Resonance Imaging. Indications et strategies pour le controle de qualite en IRM  

Energy Technology Data Exchange (ETDEWEB)

In this article, the authors recall the factors apt to influence image quality in NMR Imaging and present the european works that have been developed in MRIQA to set 5 quality assurance tests: EUROSPIN 1 to 5.

1993-01-01

475

Proceedings: Image Understanding Workshop  

Energy Technology Data Exchange (ETDEWEB)

Sponsored by the Defense Advanced Research Projects Agency the Image Understanding Workshop is a forum for the presentation of new research in vision, image analysis, and geometric modeling. Leading scientists present overviews of projects underway at major universities and corporate research sites, as well as results of individual work. The 1987 volume contains 94 articles and technical reports in two volumes.

1987-01-01

476

Point/counterpoint: dose-related issues in cardiac CT imaging  

British Library Electronic Table of Contents (United Kingdom)

This manuscript reviews some of the more controversial dose-related issues in cardiac CT imaging. Discussion covers the relative merits of cardiac CT versus MR, advantages and concerns regarding gated versus nongated cardiac CT and advantages and concerns regarding the use of breast shields in girls undergoing cardiac CT imaging.

2011-01-01

477

PET and MR imaging in a neuro-Behcet syndrome  

Energy Technology Data Exchange (ETDEWEB)

Positron emission tomography (PET) and magnetic resonance imaging (MRI) studies were performed on a case of neuro-Behcet's syndrome. In accordance with the clinical signs, FDG PET (using /sup 18/F-labeled 2-F-2'-desoxyglucose) revealed disseminated storage defects in the cerebrum and cerebellum. Focal regions of enhanced signal intensity were demonstrated in the parietal white matter of the cerebrum in T2-weighted images and in the brain stem by MRI. (orig.).

1989-11-01

478

Neutron radiography with the cyclotron, 6  

International Nuclear Information System (INIS)

The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).

1988-01-01

479

Multiple imaging radiography at LNLS  

Energy Technology Data Exchange (ETDEWEB)

An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.

2008-01-11

480

Monte Carlo design calculations for a neutron imaging facility collimator  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.

1996-12-31

481

Monoclonal antibody imaging in malignant and benign gastrointestinal diseases  

International Nuclear Information System (INIS)

The "1"3"1I-labelled monoclonal antibodies 791T/36 and 79IT/36 Fab fragments have been evaluated in the imaging of patients with colorectal cancer, with benign colorectal tumours, and with malignant tumours of other parts of the gastrointestinal tract. The results of clinical imaging have been carefully correlated with clinical findings and direct measurement of the preferential uptake of antibody by the tumours. (UK).

482

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

483

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

484

Interventional MR imaging: Clinical results obtained with a 1.5 Tesla system  

International Nuclear Information System (INIS)

The clinical feasibility of using interventional examination techniques was tested with an equipment combining fluoroscopy and MR imaging. This hybrid system showed to be of advantage in a great number of interventional examinations. The 1.5 Tesla magnet proved to be superior to open MR scanning systems in terms of image quality and scanning times. (orig.).

485

Imaging Three Dimensional Two-Particle Correlations for Heavy-Ion Reaction Studies  

Energy Technology Data Exchange (ETDEWEB)

The authors report an extension of the source imaging method for analyzing three-dimensional sources from three-dimensional correlations. The technique consists of expanding the correlation data and the underlying source function in spherical harmonics and inverting the resulting system of one-dimensional integral equations. With this strategy, they can image the source function quickly, even with the extremely large data sets common in three-dimensional analyses.

2005-06-27

486

GaAs detector optimization for different medical imaging applications  

International Nuclear Information System (INIS)

We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)

1999-09-11

487

Evaluation of Dry Chemicals by Photoacoustic Imaging  

Science.gov (United States)

In this study, an apparatus suitable to photoacoustic (PA) imaging to measure blood-analysis and urinalysis is fabricated and its measurement scheme has been established for the first time. The PA imaging of urinalysis test strip, blood sugar test strip, and cholesterol test strip is performed. A calibration curve of PA measurement is obtained for a urine test strip. The detectivity is better than that obtained by an eye-measurement.

1992-10-01

488

Accurate positioning for head and neck cancer patients using 2D and 3D image guidance  

UK PubMed Central (United Kingdom)

Our goal is to determine an optimized image-guided setup by comparing setup errors determined by two-dimensional (2D) and three-dimensional (3D) image guidance for head and neck cancer (HNC)...Full Text Available

489

Ganglioneuromas in childhood: MRI and CT characteristics; Ganglioneurome im Kindesalter: CT- und MRT-Charakteristika  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub 1}-weighted scans the ...

2000-05-01

490

CuPt-type ordering of MOCVD In{sub 0.49}Al{sub 0.51}P.  

Science.gov (United States)

CuPt-type ordering in In{sub 0.49}Al{sub 0.51}P is studied by TEM. The lattice-matched film was grown by MOCVD on a GaAs substrate oriented 10{sup o} off (001) towards [110], at 650 C and 25 nm/min. TEM [110] and [1{bar 1}0] cross-sections (XS) were made by wedge polishing and 2 kV Ar ion milling. In CuPt-type ordering of In{sub 0.52}Ga{sub 0.48}P, alternating In-Ga-In-Ga {l_brace}111{r_brace} planes of group III atoms produce 1/2 {bar 1}11 and 1/2 1{bar 1}1 order spots in the 110 SADP, while the [1{bar 1}0] SADP shows no order spots [1-3]. A few studies have reported this type of order in In{sub 0.49}Al{sub 0.51}P [4]. The 004 BF image of the [1{bar 1}0] XS in Fig. 1 shows uneven light/dark contrast modulation due to phase separation often observed in In{sub 0.52}Ga{sub 0.48}P. There are also light/dark layers marked ML parallel to the film growth plane; such unintentional multilayers have also been observed [5] but their origin is not understood. Order lamellae ...

2002-03-14

491

Visualization of disturbed flow with spin-echo and cine MR imaging  

International Nuclear Information System (INIS)

MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.

492

VSP reverse-time migration  

Energy Technology Data Exchange (ETDEWEB)

VSP reverse-time migration is a well adaptable wave equation migration method. Its control equation not only describes all-direction propagation of seismic wave but also removes interbed multiples. Clearbout's image principle is generalized to determine image conditions, real VSP data are used to determine boundary condition, and two way reflection-free wave equation is solved by making reverse-time extrapolation. In each step of extrapolation, the migration value at relevant image point is obtained by using the image condition. The complete migration of a seismic section is achieved when reverse-time extrapolation reaches the minimum image time. In this paper it is proved theoretically and practically that this method is applicable to any velocity variation and makes the migrated section have both good resolution and high S/N ratio. Besides, this method results in high ...

1991-01-01

493

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect ...

2009-09-01

494

The VOISE Algorithm: a Versatile Tool for Automatic Segmentation of Astronomical Images  

CERN Document Server

The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean ...

2009-01-01

495

Synthesis and biodistribution of "9"9"mTc-peptides conjugated adenine as tumor imaging agents  

International Nuclear Information System (INIS)

Two peptide ligands conjugated adenine, [9-N-(tritylmercapto acetyl diglycyl aminoethyl) adenine, Tr-MAG_2-Ade] and [9-N-(tritylmercapto acetyl triglycyl aminoethyl) adenine, Tr-MAG3-Ade], are synthesized and labeled with "9"9"mTc by directly labeling method. The stability of "9"9"mTc-MAG_2- adenine and "9"9"mTc-MAG_3-adenine in vitro is measured. The uptake radios of tumor to muscle at 3h post-injection are 5.70 and 4.92, respectively. The biodistribution and scintigraphic imaging studies show that the two complexes have high localization in tumor and high contrasted tumor images can be obtained, which suggest their potential utility as tumor imaging agents. But the high radioactivity of abdomen could prevent the tumor imaging in this area. (author)

2007-07-01

496

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized ...

1983-11-01

497

PET and MRI in cardiac imaging: from validation studies to integrated applications  

International Nuclear Information System (INIS)

Positron emission tomography (PET) is the gold standard for non-invasive assessment of myocardial viability and allows accurate detection of coronary artery disease by assessment of myocardial perfusion. Magnetic resonance imaging (MRI) provides high resolution anatomical images that allow accurate evaluation of ventricular structure and function together with detection of myocardial infarction. Potential hybrid PET/MR tomography may potentially facilitate the combination of information from these imaging modalities in cardiology. Furthermore, the combination of anatomical MRI images with the high sensitivity of PET for detecting molecular targets may extent the application of these modalities to the characterization of atherosclerotic plaques and to the evaluation of angiogenetic or stem cell therapies, for example. This article reviews studies using MRI and PET in parallel to compare their performance ...

2009-03-01

498

Combined migration velocity model-building and its application in tunnel seismic prediction  

Science.gov (United States)

We propose a combined migration velocity analysis and imaging method based on Kirchhoff integral migration and reverse time migration, using the residual curvature analysis and layer stripping strategy to build the velocity model. This method improves the image resolution of Kirchhoff integral migration and reduces the computations of the reverse time migration. It combines the advantages of efficiency and accuracy of the two migration methods. Its application in tunnel seismic prediction shows good results. Numerical experiments show that the imaging results of reverse time migration are better than the imaging results of Kirchhoff integral migration in many aspects of tunnel prediction. Field data show that this method has efficient computations and can establish a reasonable velocity model and a high quality imaging section. Combination with geological information can make an ...

2010-09-01

499

Camera position estimation and feature extraction from an incomplete image of a landmark  

British Library Electronic Table of Contents (United Kingdom)

In the autonomous unmanned helicopter landing problem, the position of the unmanned helicopter relative to the landmark is very important. A camera carried on the unmanned helicopter can capture an image of the landmark. In earlier research, it was reported that the camera position could be estimated by features extracted from the landmark image. However, it is necessary that the landmark image should be complete, or with only slight deficiencies, in order for this estimation process to be possible. In this article, we report on an innovative design for an estimation made from a camera position giving an incomplete single image of the landmark. An adaptive neuro-fuzzy inference system (ANFIS) is used to construct the mapping relation between the features of complete and incomplete landmark...

2011-01-01

500

A Multi-Layered Image Cache for Scientific Visualization  

Energy Technology Data Exchange (ETDEWEB)

We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.

2003-06-26