WorldWideScience
1

Use of portable HPGE detector and multichannel analyzer for in-situ gamma spectrometry of soil  

International Nuclear Information System (INIS)

Measurement of fission and activation products in the soil or over a plane grass land of a nuclear power station environment is required to find out the long term changes. The inventory of radionuclides in the soil is routinely determined by soil sampling, processing and gamma spectrometry in the laboratory. The method although is proven and accurate is time consuming and largely dependent on homogenous distribution. Therefore, an alternative and rapid method of in-situ gamma spectrometry using portable devices was standardized to determine the concentration of radionuclides in soil, for regular environmental monitoring as well as during emergency condition. The paper presents the methodology, ready to use factors and compares the results of a few measurements made in the environment of Tarapur Atomic Power Station by both in-situ and laboratory methods. ...

2005-11-23

2

Investigation of W"1"7"7 decay scheme by #gamma##gamma#-coincidence method  

International Nuclear Information System (INIS)

... coincidence spectrometry decay excited states gamma spectra half-life

1973-01-29

3

Radon and radon daughter evaluation in a natural radioactivity survey indoors  

Energy Technology Data Exchange (ETDEWEB)

An indoor survey in order to estimate the population exposure in five towns of an Italian Region is presented. A particular methodology for the campaign was planned and is being applied. Gamma spectrometry of building materials, exposure rate measurements indoors and outdoors and radon concentration measurements indoors were taken with different techniques. A correlation was found between mean gamma exposure rate and mean radon concentration in the houses investigated. An evaluation of mean effective dose equivalents for the inhabitants of the five towns is reported.

1985-10-01

4

Three-dimensional data processing for time resolved gamma-ray spectrometry  

International Nuclear Information System (INIS)

A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method. (author)

5

#gamma#-#gamma# angular correlation for "1"0"1Tc transitions  

International Nuclear Information System (INIS)

... correlation beta-minus decay coincidence spectrometry experimental data

6

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 ...

1983-01-01

7

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 ...

7871-01-01

8

Decays of "8"8Kr and "8"8Rb  

International Nuclear Information System (INIS)

The #gamma# rays following the #beta# decays of "8"8Kr and "8"8Rb have been studied, using both large volume Ge(Li) detectors for singles and coincidence measurements and anti-Compton spectrometry for singles measurements. Level schemes for "8"8Rb and "8"8Sr were constructed from the data and 74 of 81 #gamma# rays observed in the decay of "8"8Kr were placed in the "8"8Rb level scheme with 23 excited states. For the decay of "8"8Rb, all of the observed 27 #gamma# rays have been placed in the (well known) level structure of "8"8Sr. Spin and parity assignments have been deduced from #beta#-decay logft values and #gamma#-ray transition patterns. Possible shell model interpretations are presented for the level schemes.

9

Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry  

International Nuclear Information System (INIS)

A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for ...

1977-11-01

10

Soil gamma ray spectrometry of the Buquira river basin, SP, Brazil; Gamametria de solos da bacia do rio Buquira, SP, Brazil  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactivity found in rocks and its evaluation been frequently used for studies of environmental geochemistry, particularly those of detection and control of pollutants and the consequent changes in environment after antropic interferences. In this work natural radioactivity in forty nine soil samples in the basin of Buquira river, at the Northeast region of Sao Paulo State, has been analysed and measured with a Ge-HP gamma ray spectrometer. A table with the most relevant results found in rocks is shown and discussed. (author)

2002-12-01

11

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

12

High resolution gamma-ray spectrometry of culverts containing transuranic waste at the Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.

1990-01-01

13

High resolution gamma-ray spectrometry of culverts containing transuranic waste at the Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.

1990-12-31

14

Studies on natural radioactivity of some egyptian building materials  

International Nuclear Information System (INIS)

Using high-resolution y-rays spectrometry, the natural radioactivity of 14 samples of natural and o manufactured Egyptian building materials have been investigated. The samples were collected from local market and construction sites. From the measured gamma-ray spectra, specific activities were determined. The radium equivalent activity in each sample was estimated. Radiological evaluations of these materials indicate that all materials meet the external gamma-ray dose limitation. Calculation of concentration indices by assuming a Markkanen room model is constructed from these materials, to find the excess gamma-ray dose taken over that received from the outdoors. The Austrian Standard ONORM S 5200 is used in testing the building materials.

2004-02-24

15

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for ...

16

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated ...

1985-03-01

17

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

18

Selective dissolution and surface enrichment of alloy components of passivated Fe 18Cr and Fe 18Cr3Mo single crystals  

International Nuclear Information System (INIS)

The possible surface enrichment of chromium and molybdenum during dissolution of Fe18Cr (110) and Fe18Cr3Mo (110) alloys at constant potentials in the passive region is elucidated by taking into account quantitative information on partial dissolution rates of alloy components as measured by #gamma#-spectrometry and on chemical composition of passivating films as measured by ESCA and AES. When combining results from all methods it is found that chromium under all conditions is enriched in the passivating films. An accumulation of chromium in the alloy is also indicated. For molybdenum, an enrichment in the passive film is observed at -0.2 V (SCE), whereas in the potential interval 0.1 - 0.9 V, the molybdenum enrichment as determined by ESCA and AES is hardly significant. On the other hand, #gamma#-spectrometry gives a clear indication of molybdenum enrichment in both potential. (author).

2008-12-30

19

Levels in "9"7Tc, "9"9Tc, "1"0"1Tc and "1"0"1Ru  

International Nuclear Information System (INIS)

... Thesis (Ph.D.). coincidence spectrometry excited states gamma spectra internal

20

Analysis of #alpha#-emitters in the VLSI packaging materials  

International Nuclear Information System (INIS)

The advance in the analysis of very small amount (<= 1#alpha#/cm"2h) of #alpha#-emitters in the cited materials is reviewed. The review, for which 75 references are listed, covers the period from January, 1978, to June, 1982. The use of #alpha#-ray counting, #alpha#-ray spectrometry, #gamma#-ray spectrometry, neutron activation analysis and mass spectrometry is discussed, and their relative merit and limitation are outlined. (J.P.N.).

21

Concentration of radiocaesium {sup 137}Cs and {sup 134}Cs in sediments of the Malaysian marine environment  

Energy Technology Data Exchange (ETDEWEB)

The concentrations of {sup 137}Cs and {sup 134}Cs in Malaysian marine sediments were measured by gamma-ray spectrometry with a high-purity germanium (HPGe) detector connected to a multichannel analyzer. In general, the {sup 137}Cs concentration in Malaysian marine sediments has been found to be very low and less than 5 Bq/kg dry weight with the exception of those from a few sampling locations. The concentration of {sup 134}Cs was found to be less than the minimum detectable activity for the measuring condition used. Data reported in this paper were found to be comparable with results from within the region and thus can be used as reference data for the country.

2007-12-15

22

Analytical validation of accelerator mass spectrometry for pharmaceutical development  

UK PubMed Central (United Kingdom)

The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of 14C/C ratio, independent of chemical separation procedures....Full Text Available

2010-03-01

23

Investigation of natural radionuclides in selected NORM-samples  

International Nuclear Information System (INIS)

A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different ...

2005-09-20

24

Evaluation of induced radioactivity in 10 MeV-electron irradiated spices, (1)  

International Nuclear Information System (INIS)

Black pepper, white pepper, red pepper, ginger and turmeric were irradiated with 10 MeV electrons from a linear accelerator to a dose of 100 kGy and radioactivity was measured in order to estimate induced radioactivity in the irradiated foods. Induced radioactivity could not be detected significantly by #gamma#-ray spectrometry in the irradiated samples except for spiked samples which contain some photonuclear target nuclides in the list of photonuclear reactions which could produce radioactivity below 10 MeV. From the amount of observed radioactivities of short-lived photonuclear products in the spiked samples and calculation of H_5_0 according to ICRP Publication 30, it was concluded that the induced radioactivity and its biological effects in the 10 MeV electron-irradiated natural samples were negligible in comparison with natural radioactivity from "4"0K contained in the samples. (author).

25

Chemical Analysis of Solid-State Irradiated Human Insulin  

British Library Electronic Table of Contents (United Kingdom)

Purpose To study the chemical modifications induced upon irradiation of solid human insulin at radiosterilization doses and investigate the influence of the absorbed dose on radiolysis. Materials and Methods Volatile radiolytic products were monitored by gas chromatography coupled with mass spectrometry (GC-MS) and non-volatile products by two different high performance liquid chromatography (HPLC) methods: the formation of higher molecular weight proteins was assessed by size exclusion liquid chromatography whereas assays for related compounds and chemical potency tests were carried out using reverse-phase HPLC-UV. Conformational changes were investigated by measurements of circular dichroism. Results After gamma irradiation at 10?kGy, the recovery of insulin was 96.8%; higher molecular w...

2006-01-01

26

Quantification of "2"3"5U and "2"3"8U activity concentrations for undeclared nuclear materials by a digital gamma-gamma coincidence spectroscopy  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium ...

2011-06-01

27

Laser monitoring of the size and polarization of the gamma beams of #gamma##gamma# and e#gamma# colliders  

International Nuclear Information System (INIS)

It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).

28

Age determination of plutonium material in nuclear forensics by thermal ionisation mass spectrometry  

International Nuclear Information System (INIS)

Age is a key parameter when deducing the history of plutonium material, i.e. the plutonium produced in the nuclear reactors. This is of vital importance, when a smuggled plutonium sample has been seized and the origin has to be determined. A methodology is described which allows accurately to determine the age of plutonium material by thermal ionisation mass spectrometry using independent parent/daughter relations. This has been demonstrated for Reference Materials of known ages as well as for real samples. The already established method using gamma spectrometry is compared to this. (orig.)

2000-02-01

29

Molar extinction coefficients of some biologically important substances  

International Nuclear Information System (INIS)

Reliable values of x-ray and gamma-ray attenuation coefficients of elements and compounds are required in spectrometry as well as in many other scientific, engineering and medical disciplines involving photon radiation

2002-11-15

30

Measuring the beam polarizations and the luminosity at photon-photon colliders  

Energy Technology Data Exchange (ETDEWEB)

We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)

1993-11-01

31

A database for QA/QC in neutron activation analysis and gamma-ray spectrometry  

International Nuclear Information System (INIS)

A database has been designed for storing, retrieving and analyzing information about samples, experimental conditions and results obtained by neutron activation analysis and gamma-ray spectrometry. It has been created using Microsoft ACCESS 2002 under a Windows operating system. The database has been designed not only for saving information but also for quality assurance and quality control purposes. The structure of the relational design has been discussed and demonstrated with a new graphical feature of ACCESS 2002 called PIVOTCHART. (author)

2007-04-01

32

Incineration of {sup 241}Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of the {sup 241}Am incineration in a high-intensity thermal neutron flux was carried out at the high-flux reactor of the Institut Laue-Langevin in Grenoble. The combination of nuclear {gamma}-ray spectroscopy and off-line mass spectrometry methods made possible the measurement of several parameters of the transmutation chain and the first experimental determination of the unknown {sup 242gs}Am thermal neutron capture cross section, which plays an essential role in the {sup 241}Am incineration process. During a 19 days irradiation in a thermal neutron flux of 5.6x10{sup 14} n/(s cm{sup 2}), (46{+-}5)% of the initial {sup 241}Am was transmuted by neutron capture of which (22{+-}8)% was incinerated by nuclear fission. A value of the thermal neutron cross section of {sup 242gs}Am(n,{gamma}) of (330{+-}50) barns was obtained. We show that this keeps the option open to incinerate {sup ...

2001-10-22

33

Instruments for X-ray fluorescence analysis and spectrometry  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.

34

Study on the angular. gamma gamma. -correlations for nuclei of Sr even-even isotopes  

Energy Technology Data Exchange (ETDEWEB)

The angular ..gamma gamma..-correlations for nuclei of Sr even-even isotopes with A=82, 84, 86, 88 were measured. Multipole structurs of ..gamma..-transtion series and th coefficients multipole mixing were determined.

1984-05-01

35

Study on the angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes  

International Nuclear Information System (INIS)

The angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes with a=8 82, 84, 86, 88 were measured. Multipole structurs of #gamma#-transtion series and th coefficients multipole mixing were determined.

1983-04-01

36

Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences  

Science.gov (United States)

The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)

1973-08-01

37

Measurement of the enrichment of uranium in the pipework of a gas centrifuge enrichment plant  

Energy Technology Data Exchange (ETDEWEB)

The US and UK have been separately working on the development of a NDA instrument to determine the enrichment of gaseous UF/sub 6/ at low pressures in cascade header pipework in line with the conclusions of the Hexapartite Safeguards Project viz. the instrument is capable of making a ''go/no go'' decision of whether the enrichment is less than/greater than 20%. Recently, there has been a series of very useful technical exchanges of ideas and information between the two countries. This has led to a technical formulation for such an instrumentation based on ..gamma..-ray spectrometry which, although plant-specific in certain features, nevertheless is based on the same physical principles. Experimental results from commercially operating enrichment plants are very encouraging and indicate that a complete measurement including set up time on the pipe should be attainable in about 30 minutes ...

1985-01-01

38

Individual monitoring of internal exposure to uranium oxides in two fuel fabrication plants. La surveillance individuelle de l'exposition interne aux oxydes d'uranium dans deux usines de fabrication du combustible  

Energy Technology Data Exchange (ETDEWEB)

Individual monitoring of personal exposure to inhalation of uranium oxides throughout the manufacture of fuel for pressurized water reactor (PWR) includes lung gamma-spectrometry, fecal analysis and urine analysis. Examination of the results shows the following: internal exposure is the consequence of repeated intake incidents as revealed by early peaks of urinary and particularly fecal elimination; a shift is often observed with the results of aerosol concentration measured through air collectors; the measured variations of uranium lung incorporations are relatively fast (apparent mean period 165 d). Correct evaluation of the effective dose equivalent from inhalation requires further information concerning the aerosol size distribution at work stations, the physico-chemical characteristics of the product leading to an estimate of its actual biological solubility, and the measurement of the fraction of ...

1989-01-01

39

Excitation functions for proton-induced reactions on natural hafnium: Production of {sup 177}Lu for medical use  

Energy Technology Data Exchange (ETDEWEB)

There is an increasing interest in using radioisotopes of rare earth elements for internal radiotherapy and for imaging in nuclear medicine. {sup 177}Lu is one of the promising radionuclides. This article reports on the first measurements of the excitation function for the production of {sup 177}Lu with proton-beam energies up to 17 MeV on natural hafnium targets. The experimental cross sections for the reaction {sup nat}Hf(p,x){sup 177}Lu were obtained by the activation of a stacked-foil target and subsequent gamma spectrometry. Theoretical cross sections were calculated up to 35 MeV with the EMPIRE nuclear reaction model code. The measured and calculated cross sections were used for deriving the thick-target yields and for estimating the production of other nuclides than {sup 177}Lu. Measured production cross sections of {sup 175,176,177,178}Ta on the same target are also ...

2009-11-15

40

Excitation functions for proton-induced reactions on natural hafnium: Production of "1"7"7Lu for medical use  

International Nuclear Information System (INIS)

There is an increasing interest in using radioisotopes of rare earth elements for internal radiotherapy and for imaging in nuclear medicine. "1"7"7Lu is one of the promising radionuclides. This article reports on the first measurements of the excitation function for the production of "1"7"7Lu with proton-beam energies up to 17 MeV on natural hafnium targets. The experimental cross sections for the reaction "n"a"tHf(p,x)"1"7"7Lu were obtained by the activation of a stacked-foil target and subsequent gamma spectrometry. Theoretical cross sections were calculated up to 35 MeV with the EMPIRE nuclear reaction model code. The measured and calculated cross sections were used for deriving the thick-target yields and for estimating the production of other nuclides than "1"7"7Lu. Measured production cross sections of "1"7"5","1"7"6","1"7"7","1"7"8Ta on the same target are also presented.

2009-11-01

41

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The ...

1998-06-01

42

Decoupling of uranium metal with borated plaster using /sup 252/Cf nose analysis methods  

Energy Technology Data Exchange (ETDEWEB)

The use of borated plaster to isolate uranium (93.2 wt % /sup 235/U) metal was studied in a series of subcritical experiments with uranium metal cylinders (7.0 in. diam, 2.0 in. thick) and slabs (approx.1.4 x approx.5.4 x approx.10.1 in. dimensions). In the cylindrical experiments, the thickness of borated plaster was varied up to 10 in. and the subcriticality measured using the /sup 252/Cf-source-driven neutron noise analysis method. In the experiments with the uranium slabs, an array of slabs 3 wide and 8 high was assembled in steps to demonstrate the subcriticality of this array with 3.75-in.-thick borated plaster as an isolating material between all uranium slabs. In the slab experiments, both noise analysis and source neutron multiplication measurements were performed. Before assembly of the slab array the presence of boron in the plaster was verified by neutron transmission and gamma-ray ...

1985-01-01

43

Cross-section measurements for (n, 2a) (n, p) and (n, #alpha#) reactions on strontium isotopes at the neutron energy about 14 MeV  

International Nuclear Information System (INIS)

Cross-sections for "8"4Sr(n, 2n)"8"3Sr, "8"6Sr(n, 2n)"8"5"mSr, "8"6Sr(n, 2n)"8"5Sr, "8"8Sr(n, 2n)"8"7"mSr, "8"4Sr(n, p)"8"4Rb, "8"6Sr(n, p)"8"6Rb, "8"8Sr(n, p)"8"8Rb and "8"8Sr(n, #alpha#)"8"5"mKr reactions have been measured at neutron energies from 13.5 to 14.6 MeV using activation technique and by means of #gamma#-ray spectrometry. The neutron flux was determined using the monitor reaction "9"3Nb(n, 2n)"9"2"mNb and the neutron energies were measured by the method of cross-section ratios for "9Zr(n, 2n)"8"9Zr to "9"3Nb (n, 2n)"9"2"mNb reactions. The results of present work are compared with data published previously.

2006-01-01

44

#gamma##gamma# Cross-sections and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We summarize the predictions of different models for total #gamma##gamma# cross-sections. The experimentally observed rise of #sigma#_#gamma#_#gamma# with s radical _#gamma#_#gamma#, faster than that for #sigma#_p_-_b_a_r_p, #sigma#_#gamma#_p is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of #sigma#_#gamma#_#gamma# with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range 300< s radical_#gamma#_#gamma# <500 GeV. We further show that the difference in ...

2001-10-11

45

Semihard production of tensor mesons in #gamma##gamma#-collisions and the perturbative Odderon  

International Nuclear Information System (INIS)

The cross sections of neutral tensor mesons T=a_2, f, f', ... production in the exclusive #gamma##gamma##->#TT' or semiexclusive #gamma##gamma##->#TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV"2 are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future #gamma##gamma#-colliders is discussed too. (orig.).

46

Study of iodine migration in zirconia using stable and radioactive ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The large uranium fission cross section leading to iodine and the behaviour of this element in the cladding tube during energy production and afterwards during waste storage is a crucial problem, especially for {sup 129}I which is a very long half-life isotope (T=1.59 x 10{sup 7} yr). Since a combined external and internal oxidation of the zircaloy cladding tube occurs during the reactor processing, iodine diffusion parameters in zirconia are needed. In order to obtain these data, stable iodine atoms were first introduced by ion implantation into zirconia with an energy of 200 keV and a dose equal to 8 x 10{sup 15} at cm{sup -2}. Diffusion profiles were measured using 3 MeV alpha-particle Rutherford backscattering spectrometry at each step of the annealing procedure between 700 C and 900 C. In such experiments a reduced iodine concentration was observed, which correlated to a diffusion-like process. Similar analysis has been performed using ...

1998-03-01

47

Gamma spectrometry calibrations with natural radioactive materials  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).

1996-02-01

48

Gamma spectrometry calibrations with natural radioactive materials  

International Nuclear Information System (INIS)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).

49

A review of 4 norm industries in Ireland  

Energy Technology Data Exchange (ETDEWEB)

Full text: This presentation will review the progress achieved so far by the Irish national regulatory agency, the Radiological Protection Institut e of Ireland (R.P.I.I.) in the investigation of work activities where the presence of natural radiation sources (NORM) could lead to a significant increase in exposure to workers or members of the public which cannot be disregarded from the radiation protection point of view. Since the coming into force in Ma y 2000 of the Radiological Protection Act, 1991 (Ionising Radiation) Order, 2000 (S.I. No. 125 of 2000) which implements the Eu B.S.S. Directive 96/29/EURATOM, four major NORM industries currently active in Ireland have been investigated. According to the literature, they are all considered liable to involve work practices resulting in exposure to NORM. They include: the gas extraction and production industry, the peat- and coal-firing power generation industry and the bauxite/alumina refining industry. For the gas industry, monitoring ...

2006-07-01

50

Standard deviation of measurement results in x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

The standard deviation of measurement results of a given element in XRF spectrometry depends on three factors: concentration and concentration region, atomic number and matrix. The effects of these factors were investigated by an XRF instrument type ARL 72.000 for aluminium metal, bauxite-red mud and aluminium using computerized data processing. A comparison of linear and nonlinear relation between concentration and the result of XRF analysis was made for the determination of standard deviation. (R.P.).

1984-11-13

51

Activation cross sections of deuteron-induced nuclear reactions on hafnium  

International Nuclear Information System (INIS)

Experimental excitation functions for deuteron-induced reactions up to 20 MeV on high purity natural hafnium were measured with the activation method using a stacked foil irradiation technique. Metallic hafnium foils with thickness of 10 #mu#m were stacked together with 50 #mu#m thick aluminium and 12 #mu#m thick titanium foils. The aluminium foils served as energy absorber while the titanium foils were used to monitor the energy and intensity of the bombarding deuteron beam. From a detailed remeasurement of the complete excitation function of the "n"a"tTi(d,x)"4"8V monitor reaction it was possible to adopt the proper incident energy and beam intensity by comparing the results with the recommended values. High resolution off-line gamma-ray spectrometry was applied to assess the activity of each foil. From the measured activity independent and/or cumulative elemental or isotopic cross section data for ...

2010-11-15

52

National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards  

International Nuclear Information System (INIS)

As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible spectral features of ...

2009-12-16

53

Isolation and determination of "9"0Sr, "2"2"6Ra, "2"2"8Ra and "2"1"0Pb in food  

International Nuclear Information System (INIS)

A procedure is described for the isolation and determination of "9"0Sr, "2"2"6Ra, "2"2"8Ra and "2"1"0Pb in food. These nuclides are highly radiotoxic, above all for babies and children. Samples are dry ashed, alkali metals are removed as carbonates. Separation from other matrix ions and separation of Ra, Sr and Pb can be achieved with a column of Sr-Spec, an immobilized crown ether. For activity measurements membrane filters with SrSO_4, Ba(Ra)SO_4 and PbS are prepared. Ra is determined by gamma-spectrometry, "9"0Sr and "2"1"0Pb are determined by low-level-betacounting. The determination limits are 10 mBq/kg for "9"0Sr and "2"1"0Pb and 50 mBq/kg for "2"2"6Ra and "2"2"8Ra. The procedure is useful for all kinds of foodstuff. (orig.).

54

Gamma-gamma collider based on Compton back-scattering  

International Nuclear Information System (INIS)

A #gamma##gamma# collider would extend and complement the physics capability of a linear collider; e.g. it would be suitable for direct measurement of the partial decay width of a Higgs boson into two gamma quanta. This paper discusses choice of laser parameters, luminosity optimization, electron and laser parameters for a gamma- gamma collider as a second interaction region for the Next Linear Collider, laser path, and the lasers. It is concluded that a gamma- gamma collider is technically feasible; however it will require a significant investment in preparatory R ampersand D.

1996-08-25

55

Estimation of annual effective dose due to natural radioactive elements in ingestion of foodstuffs in tin mining area of Jos-Plateau, Nigeria  

Energy Technology Data Exchange (ETDEWEB)

Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of {sup 40}K, {sup 238}U and {sup 232}Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of {sup 40}K, {sup 238}U and {sup 232}Th in local prepared diets ranged between 60 and 494 Bq kg{sup -1}, between BDL and 48 Bq kg{sup -1} and between BDL and 17 Bq kg{sup -1}, respectively. The internal effective dose to individuals from ...

2007-04-15

56

Estimation of annual effective dose due to natural radioactive elements in ingestion of foodstuffs in tin mining area of Jos-Plateau, Nigeria  

International Nuclear Information System (INIS)

Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of "4"0K, "2"3"8U and "2"3"2Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of "4"0K, "2"3"8U and "2"3"2Th in local prepared diets ranged between 60 and 494 Bq kg"-"1, between BDL and 48 Bq kg"-"1 and between BDL and 17 Bq kg"-"1, respectively. The internal effective dose to individuals from the consumption of the food ...

2007-04-01

57

Measurements of the CKM angle $\\gamma/\\phi_{3}$ at B-factories  

CERN Document Server

The CKM angle $\\gamma/\\phi_{3}$ had been measured by two B-factories, the PEPII collider for the BaBar experiment and the KEKB collider for the Belle experiments. The present paper reports recent progress in $\\gamma/\\phi_{3}$.

2011-01-01

58

Alpha particle induced fission of sup 209 Bi at 55. 7 and 58. 6 MeV  

Energy Technology Data Exchange (ETDEWEB)

The alpha particle induced fission of {sup 209}Bi has been investigated for E{sub {alpha}} = 55.7 and 58.6 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The mass distributions have been found to be broad with a peak near mass 104. The charge distribution has been studied at the same particle energies. The fractional cumulative yields of {sup 97}Zr, {sup 99}Mo, {sup 101}Mo, {sup 112}Pd and {sup 117m}Cd have been determined using gamma ray spectrometry. The width of charge distribution is broad. (orig.).

1991-01-01

59

Alpha particle induced fission of "2"0"9Bi at 55.7 and 58.6 MeV  

International Nuclear Information System (INIS)

The alpha particle induced fission of "2"0"9Bi has been investigated for E_#alpha# = 55.7 and 58.6 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The mass distributions have been found to be broad with a peak near mass 104. The charge distribution has been studied at the same particle energies. The fractional cumulative yields of "9"7Zr, "9"9Mo, "1"0"1Mo, "1"1"2Pd and "1"1"7"mCd have been determined using gamma ray spectrometry. The width of charge distribution is broad. (orig.).

60

Studying the triple-Higgs vertex in the process. gamma. gamma. yields HH at TeV energies  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process {gamma}{gamma}{yields}HH are calculated. It is shown that the cross section is measurable at TeV {gamma}{gamma} colliders and is marginally sensitive to the triple-Higgs variation. (orig.).

1992-06-04

61

Studying the triple-Higgs vertex in the process #gamma##gamma##->#HH at TeV energies  

International Nuclear Information System (INIS)

In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process #gamma##gamma##->#HH are calculated. It is shown that the cross section is measurable at TeV #gamma##gamma# colliders and is marginally sensitive to the triple-Higgs variation. (orig.).

62

DETERMINATION OF 237NP AND PU ISOTOPES IN LARGE SOIL SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY  

Energy Technology Data Exchange (ETDEWEB)

A new method for the determination of {sup 237}Np and Pu isotopes in large soil samples has been developed that provides enhanced uranium removal to facilitate assay by inductively coupled plasma mass spectrometry (ICP-MS). This method allows rapid preconcentration and separation of plutonium and neptunium in large soil samples for the measurement of {sup 237}Np and Pu isotopes by ICP-MS. {sup 238}U can interfere with {sup 239}Pu measurement by ICP-MS as {sup 238}UH{sup +} mass overlap and {sup 237}Np via {sup 238}U peak tailing. The method provides enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then transferring Pu to DGA resin for additional purification. The decontamination factor for removal of uranium from plutonium for this method is greater than 1 x 10{sup 6}. Alpha spectrometry can also be applied so that the shorter-lived {sup 238}Pu isotope can be ...

2010-07-26

63

Semihard production of tensor mesons in. gamma. gamma. -collisions and the perturbative Odderon  

Energy Technology Data Exchange (ETDEWEB)

The cross sections of neutral tensor mesons T=a{sub 2}, f, f', ... production in the exclusive {gamma}{gamma}{yields}TT' or semiexclusive {gamma}{gamma}{yields}TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV{sup 2} are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future {gamma}{gamma}-colliders is discussed too. (orig.).

1992-03-01

64

Radon exhalation from and diffusion in concrete  

International Nuclear Information System (INIS)

Cylindrical test pieces of concrete are used for measurements of "2"2"2Rn exhalation rates. Except one flat end surface of a test piece, other parts of its exteriority are covered with sealant. Radon atoms can escape only through its end surface from the interior into the outside air. This treatment makes the radon transport in the concrete one dimensional phenomena. The piece is put in an airtight container. Time variations of radon concentrations in the air of the container are measured with a plane multiwire-electrode ionization chamber. From this result, the radon areal exhalation rate is deduced for the piece. Exhalation rates are measured for four pieces with different length. Then, the diffusion coefficient is obtained for radon in the concrete as (5.0 #+-# 1.0) x 10"-"8m"2s"-"1 (a one-block method). A two-block method has been invented to obtain simultaneously values of three parameters: diffusion coefficient, ...

1990-12-01

65

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

66

Cation Involvement in Telomestatin Binding to G-Quadruplex DNA  

UK PubMed Central (United Kingdom)

The binding mode of telomestatin to G-quadruplex DNA has been investigated using electrospray mass spectrometry, by detecting the intact complexes formed in ammonium acetate. The mass measurements show...Full Text Available

67

Direct gamma-spectrometry of surface activity with IGC-30 HPGe detector  

International Nuclear Information System (INIS)

The IGC-30 HPGe detector with MCA 'CANBERRA-10 PLUS' allows to determine surface contamination of areas of any type with a minimum error in radius 8-10 m, at a 'uniform' contamination. A modification of the CANBERRA hardware and software is described allowing determination of both the activity of a possible 'radioactive spot' and the activity of the whole observed surface. (author).

1993-12-02

68

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant ...

2007-08-21

69

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. ...

2007-08-21

70

Fission yield measurements by inductively coupled plasma mass-spectrometry  

International Nuclear Information System (INIS)

Correct prediction of the fission products inventory in irradiated nuclear fuels is essential for accurate estimation of fuel burnup, establishing proper requirements for spent fuel transportation and storage, materials accountability and nuclear forensics. Such prediction is impossible without accurate knowledge of neutron induced fission yields. The uncertainty of the fission yields reported in the ENDF/B-VII.0 library is not uniform across all of the data and much of the improvement is desired for certain fissioning isotopes and fission products. We discuss our measurements of cumulative fission yields in nuclear fuels irradiated in thermal and fast reactor spectra using Inductively Coupled Plasma Mass Spectrometry. (author)

2009-11-01

71

Fission yield measurements by inductively coupled plasma mass-spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Correct prediction of the fission products inventory in irradiated nuclear fuels is essential for accurate estimation of fuel burnup, establishing proper requirements for spent fuel transportation and storage, materials accountability and nuclear forensics. Such prediction is impossible without accurate knowledge of neutron induced fission yields. The uncertainty of the fission yields reported in the ENDF/B-VII.0 library is not uniform across all of the data and much of the improvement is desired for certain fissioning isotopes and fission products. We discuss our measurements of cumulative fission yields in nuclear fuels irradiated in thermal and fast reactor spectra using Inductively Coupled Plasma Mass Spectrometry.

2009-01-01

72

Excitation function of the {sup 64}Ni({alpha},p){sup 67}Cu reaction for production of {sup 67}Cu  

Energy Technology Data Exchange (ETDEWEB)

The excitation function of the {sup 64}Ni({alpha},p){sup 67}Cu reaction was measured from threshold up to 24 MeV in order to investigate the possibility of production of the {beta}{sup -}-emitting therapeutic radioisotope {sup 67}Cu (T{sub 1/2}=61.9 h). Two stacks of thin metallic self-supporting foils of {sup 64}Ni (enrichment 77.8%) prepared by electrolytic deposition were irradiated by {alpha}-particle beams. The radioactivity was determined via HPGe detector {gamma}-ray spectrometry. Some {sup 67}Ga activity (which emits the same {gamma}-rays as {sup 67}Cu), formed via the {sup nat}Cu({alpha},x){sup 67}Ga process on trace copper impurity in the Ni foils, was also observed. Corrections were done for {sup 67}Ga activity contribution and for the {sup 67}Cu activity escape fraction from the thin Ni-foil. The maximum cross section of the {sup 64}Ni({alpha},p){sup 67}Cu reaction amounts to 34 mb at 22 ...

2004-01-01

73

On the decay of "2"0"3Bi  

International Nuclear Information System (INIS)

The radioactive decay of "2"0"3Bi is studied. A level scheme is proposed for "2"0"3Pb on the basis of #gamma#-ray and electron spectra and #gamma#-#gamma# coincidence measurements. The experimental data are compared with theoretical results obtained in a three quasiparticle approximation. (Auth.).

74

SUSY at e{gamma}/{gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the sparticle production processes e{gamma} {yields} e tilde(Z tilde){sub 1} and {gamma}{gamma} {yields} (f tilde)(f tilde and bar) at high energy e{gamma} and {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e{gamma} colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e{gamma} {yields} (e tilde)(Z tilde){sub 1}. We show that the standard background processes e{gamma} {yields} {nu}W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes ...

1994-04-01

75

SUSY at e#gamma#/#gamma##gamma# colliders  

International Nuclear Information System (INIS)

We investigate the sparticle production processes e#gamma# #-># e tilde(Z tilde)_1 and #gamma##gamma# #-># (f tilde)(f tilde and bar) at high energy e#gamma# and #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e#gamma# colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e#gamma# #-># (e tilde)(Z tilde)_1. We show that the standard background processes e#gamma# #-># #nu#W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e#gamma# #-># (e ...

1994-04-01

76

Rapid determination of "2"3"7Np and Pu isotopes in water by inductively-coupled plasma mass spectrometry and alpha spectrometry  

International Nuclear Information System (INIS)

A new method that allows rapid preconcentration and separation of plutonium and neptunium in water samples was developed for the measurement of "2"3"7Np and Pu isotopes by inductively-coupled plasma mass spectrometry (ICP-MS) and alpha spectrometry. "2"3"8U can interfere with "2"3"9Pu measurement by ICP-MS as "2"3"8UH"+ mass overlap and "2"3"7Np via peak tailing. The method provide enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then moving Pu to DGA resin for additional removal of uranium. The decontamination factor for uranium from Pu is almost 100,000 and the decontamination factor for U from Np is greater than 10,000. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration is performed using a streamlined calcium phosphate precipitation method. Purified solutions are split between ICP-MS ...

2011-01-01

77

RAPID DETERMINATION OF 237 NP AND PU ISOTOPES IN WATER BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY AND ALPHA SPECTROMETRY  

Energy Technology Data Exchange (ETDEWEB)

A new method that allows rapid preconcentration and separation of plutonium and neptunium in water samples was developed for the measurement of {sup 237}Np and Pu isotopes by inductively-coupled plasma mass spectrometry (ICP-MS) and alpha spectrometry; a hybrid approach. {sup 238}U can interfere with {sup 239}Pu measurement by ICP-MS as {sup 238}UH{sup +} mass overlap and {sup 237}Np via peak tailing. The method provide enhanced removal of uranium by separating Pu and Np initially on TEVA Resin, then moving Pu to DGA resin for additional removal of uranium. The decontamination factor for uranium from Pu is almost 100,000 and the decontamination factor for U from Np is greater than 10,000. This method uses stacked extraction chromatography cartridges and vacuum box technology to facilitate rapid separations. Preconcentration is performed using a streamlined calcium phosphate precipitation method. ...

2010-06-23

78

{gamma}{gamma} Cross-sections and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We summarize the predictions of different models for total {gamma}{gamma} cross-sections. The experimentally observed rise of {sigma}{sub {gamma}}{sub {gamma}} with s radical {sub {gamma}}{sub {gamma}}, faster than that for {sigma}{sub p-barp}, {sigma}{sub {gamma}}{sub p} is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of {sigma}{sub {gamma}}{sub {gamma}} with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for ...

2001-10-11

79

Measurement of the branching fractions for $J/\\psi\\to\\gamma\\pi^0$, $\\gamma\\eta$ and $\\gamma\\eta^{\\prime}$  

CERN Document Server

The decay modes $\\jpsi\\ar\\gamma\\pi^0, \\gamma\\eta$ and $\\gamma\\etap$ are analyzed using a data sample of 58 million $\\jpsi$ decays collected with the BESII detector at BEPC. The branching fractions are determined to be: $Br(\\jpsi\\ar\\gamma\\pi^0)=(3.13^{+0.65}_{-0.44})\\times10^{-5}$, $Br(\\jpsi\\ar\\gamma\\eta)=(11.23\\pm0.89)\\times10^{-4}$, and $Br(\\jpsi\\ar\\gamma\\etap)=(5.55\\pm0.44)\\times10^{-3}$, where the errors are combined statistical and systematic errors. The ratio of partial widths $\\Gamma(\\jpsi\\ar\\gamma\\etap)/\\Gamma(\\jpsi\\ar\\gamma\\eta)$ is measured to be $4.94\\pm0.40$, and the singlet-octet pseudoscalar mixing angle of $\\eta-\\etap$ system is determined to be $\\theta_{P}=(-22.08\\pm0.81)^{\\circ}$.

2006-01-01

80

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

81

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

82

Behavior of triterpenes from Maytenus aquifolium Martius ('espinheira santa') upon X- and gamma-rays irradiation  

International Nuclear Information System (INIS)

The behavior of the triterpenes friedelin and friedelan-3-ol, contained on the leaves of Maytenus aquifolium Martius (Celastraceae), upon several doses of X- and #gamma#-rays (10 to 100 kGy), was investigated by high resolution gas chromatography (HRGC) and high resolution gas chromatography -mass spectrometry (HRGC-MS). The friedelin content has not changed with #gamma#-irradiation, but the content of friedelan-3-ol decreased around 17% at doses of 10, 20 and 40 kGy and around 27% at doses of 60, 80 and 100 kGy. The levels of both triterpenes remained unchanged even at higher X-ray doses. Lupen-3-one was detected by HRGC-MS. (author).

83

Characterization of nuclear fuels by ICP mass-spectrometric techniques  

British Library Electronic Table of Contents (United Kingdom)

Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...

2008-01-01

84

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

Energy Technology Data Exchange (ETDEWEB)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

1999-05-01

85

Measurement of the fast neutron component in the beam of the NPL Thermal Neutron Column using a Bonner sphere spectrometer  

International Nuclear Information System (INIS)

Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)

87

A Bragg curve ionization chamber for acceleration mass spectrometry  

CERN Document Server

A Bragg curve ionization chamber for acceleration mass spectrometry

1985-01-01

88

Measurement of #gamma#-ray emission probabilities for "1"0"1Mo  

International Nuclear Information System (INIS)

"1"0"1Mo is one of the key nuclides in diagnosing fission burn-up. However, it's difficult to measure its nuclear decay data due to its short half-life. Present study concerns in the measurements of #gamma#-ray emission probabilities, P_#gamma#, of "1"0"1Mo and "1"0"1Tc using the balance of scheme method and the entire process recording. The P_#gamma# of "1"0"1Mo by the entire process recording is about 5% lower than that by using the balance of scheme method. The P_#gamma# of "1"0"1Tc using the two methods agree each other very well. So, it seems the #gamma#-ray emission probabilities as well as measurement method still need study further for "1"0"1Mo. (authors)

2006-07-01

89

Traces of evidence. Nuclear forensics and illicit trafficking  

International Nuclear Information System (INIS)

An IAEA databank lists a number of reported cases of illicitly trafficked nuclear or other radioactive materials. Apart from the traditional concern with nuclear proliferation, the post September 11th public is now wary of a possible attack by terrorists with a nuclear or radiation dispersion device (RDD). Until now, the seized quantities have not been sufficient to manufacture a nuclear explosive device, but they might be enough to construct an RDD. Recognizing the latent global challenge to public health and safety, the G8 States (Japan, USA, Germany, France, UK, Italy, Canada, and Russia) have called for 'joint international efforts to identify and suppress illicit supply' of, and demand for, nuclear material and to deter potential traffickers. One measure gaining in significance is to identify seized material and trace it back to its origin the objective of an emerging science known as nuclear forensics. Repeatedly nuclear or other radioactive material of ...

2003-06-01

90

Semihard production of neutral pseudoscalar and tensor mesons in photon-photon collisions  

Energy Technology Data Exchange (ETDEWEB)

We investigate the semihard production of neutral pseudoscalar and tensor mesons in high-energy [gamma][gamma] collisions (M=P=[pi][sup 0], [eta], [eta]' or M=T=a[sub 2], f[sub 2], f[sub 2]'). We deal with the exclusive [gamma][gamma][yields]MM' or semi-exclusive [gamma][gamma][yields]MX reactions (X is the hadron jet with not too large mass). The considered transfer momenta are small in comparison with the photon energies and they are large in comparison with the confinement scale. The amplitudes of these processes are determined by the odderon exchange, i.e. three-gluon exchange in the lowest order of perturbative QCD. The cross sections are calculated in this approximation. The possibility of measurements at LEP and at future [gamma][gamma] colliders is discussed. (orig.).

1992-12-21

91

Oxygen-16 induced fission of [sup 209]Bi at 89. 5 MeV  

Energy Technology Data Exchange (ETDEWEB)

Oxygen-16 induced fission studies of [sup 209]Bi have been carried out at particle energies of 89.5 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The yield distribution of fission products has been found to be broad (FWHM [approx equal] mass units) with a peak near mass [approx equal] 108. The charge distribution in the [sup 16]O ion induced fission of [sup 209]Bi has also been studied at particle energy of 89.5 MeV. The relative cumulative yields of [sup 92]Sr, [sup 97]Zr, [sup 99]Mo, [sup 101]Mo, [sup 112]Pd and [sup 117m]Cd have been determined using gamma ray spectrometry. The width of charge distribution has been found to be broad. (orig.)

1994-01-01

92

Oxygen-16 induced fission of "2"0"9Bi at 89.5 MeV  

International Nuclear Information System (INIS)

Oxygen-16 induced fission studies of "2"0"9Bi have been carried out at particle energies of 89.5 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The yield distribution of fission products has been found to be broad (FWHM #approx =# mass units) with a peak near mass #approx =# 108. The charge distribution in the "1"6O ion induced fission of "2"0"9Bi has also been studied at particle energy of 89.5 MeV. The relative cumulative yields of "9"2Sr, "9"7Zr, "9"9Mo, "1"0"1Mo, "1"1"2Pd and "1"1"7"mCd have been determined using gamma ray spectrometry. The width of charge distribution has been found to be broad. (orig.).

93

Oxygen-16 induced fission of "2"0"9Bi at 89.5 MeV  

International Nuclear Information System (INIS)

The "1"6O induced fission studies of "2"0"9Bi have been carried out at particle energies of 89.5 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The yield distribution of fission products has been found to be broad (FWHM=16) with a peak near mass 107. The charge distribution in the "1"6O particle induced fission of "2"0"9Bi has been studied at "1"6O particle of 89.5 MeV. The fractional cumulative yields of "9"2Y, "9"7Zr, "9"9Mo, "1"0"1Mo, "1"0"5Rh, "1"1"2Pd and "1"1"7"mCd have been determined using gamma ray spectrometry. (author). 7 refs., 2 tabs.

94

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

95

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

96

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

97

\\psi(2S) Decays into $\\J$ plus Two Photons  

CERN Document Server

Using $\\gamma \\gamma J/\\psi, J/\\psi \\ra e^+ e^-$ and $\\mu^+ \\mu^-$ events from a sample of $14.0\\times 10^6$ $\\psip$ decays collected with the BESII detector, the branching fractions for $\\psip\\ra \\pi^0\\J$, $\\eta\\J$, and $\\psi(2S)\\ar\\gamma\\chi_{c1},\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi$ are measured to be $B(\\psip\\ra \\pi^0\\J) = (1.43\\pm0.14\\pm0.13)\\times 10^{-3}$, $B(\\psip\\ra \\eta\\J) = (2.98\\pm0.09\\pm0.23)%$, $B(\\psi(2S)\\ar\\gamma\\chi_{c1}\\ar\\gamma\\gamma\\jpsi) = (2.81\\pm0.05\\pm 0.23)%$, and $B(\\psi(2S)\\ar\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi) = (1.62\\pm0.04\\pm 0.12)%$.

2004-01-01

98

Charge distribution in alpha particle induced fission of "2"0"9Bi (Preprint No. NC-06)  

International Nuclear Information System (INIS)

The charge distribution in the alpha particle induced fission of "2"0"9Bi has been studied at alpha particle energy of 55.7 MeV and 58.6 MeV. The fractional cumulative yields of "9"7Zr, "9"9Mo, "1"0"1Mo and "1"1"2Pd have been determined using gamma ray spectrometry. The charge distribution have been found to be broad. (author). 4 refs., 1 ta b.

1991-02-04

99

Radiation-induced damage to DNA; Les lesions radio-induites de l'ADN  

Energy Technology Data Exchange (ETDEWEB)

This short survey focuses on the main radiation-induced base lesions that have been identified within cellular DNA. For this purpose, sensitive assays that are aimed at measuring a few modifications per 10{sup 7} normal bases were set-up. In that respect high performance liquid chromatography - tandem mass spectrometry (CLHP-MS/MS) was found to be able to single out the formation of 9 oxidized nucleosides and two modified nucleo-bases out of the 70 oxidative base lesions that have been identified in model systems. As a striking result, it was found that in the DNA of {gamma}-irradiated human monocytes, the formamide-pyrimidine derivative of guanine is produced in a higher yield than the ubiquitous 8-oxo-7,8-dihydro-guanine damage, both arising from the same radical precursor. However, relatively high doses of ionizing radiation (> 20 Gy) have to be applied in order to detect an increase in the level of the damage. ...

2002-03-01

100

A measurement of the parity-violating gamma-ray asymmetry in the neutron-proton capture  

Energy Technology Data Exchange (ETDEWEB)

The {rvec n} + p {yields} d + {gamma} experiment under construction at LANSCE studies the weak interaction between neutrons and protons. The experiments will measure the directional dependence of the parity-violating {gamma}-ray asymmetry, A{sub {gamma}}, in the polarized cold neutron capture by para-hydrogen. The goal is to measure A{sub {gamma}} with uncertainty of 0.5 x 10{sup -8}, 10% of its predicted value. A{sub {gamma}} primarily isolates the {Delta}I = 1 component of the hadronic weak interaction and thus will determine the long-range weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. The experiment is carefully designed for the LANSCE pulsed spallation neutron source to achieve the proposed statistical precision and to control systematic errors. We discuss the experiment and its status.

2002-01-01

101

Studies on the separation of Ag(I) during the recovery of Pu by ammonium plutonium(III) oxalate precipitation methodology  

International Nuclear Information System (INIS)

Studies on the separation of Ag(I) during the recovery of Pu from analytical waste generated during potentiometric determination of Pu using AgO as oxidant, by precipitation of Pu as ammonium plutonium (III) oxalate have shown that most of the Ag(I) is separated during the reduction of Pu to Pu(III) state by ascorbic acid. A decontamination factor of 54 was obtained. Additional a decontamination factor of 5.8 was obtained during the precipitation of Pu as ammonium plutonium (III) oxalate. The Ag content was determined by gamma spectrometry, using "1"1"1Ag as a tracer (T_1_/_2 7.45 d, #gamma# 342.1 keV) and HPGe as detector. The studies indicate that Ag is preferentially separated almost quantitatively during the recovery of plutonium, when acidity adjustment is done with NaOH instead of NH_3. (author)

2007-02-14

102

Gamma spectrometric characterisation of industrially used African and Australian bauxites and their red mud tailings  

Energy Technology Data Exchange (ETDEWEB)

From their genesis by weathering and sedimentation, bauxites, the principal aluminium ores, contain appreciable amounts of uranium and thorium. High resolution gamma spectrometry with a high purity germanium detector was used for an analysis of four industrially used bauxites from Gondama, Sierra Leone; Boke, Guinea; Weipa, Queensland, Australia; Gove, Northern Territory, Australia. Significant differences in uranium to thorium ratios and in activities of the uranium and thorium daughters were observed for the four bauxites. It was found that the bauxite from Gondama, Sierra Leone has an activity of only 10% compared with the others. Red mud tailings from such a bauxite may well be used as an additive to bricks, which is now illegal for normal red mud from more active bauxites. (author).

1992-01-01

103

Gamma spectrometric characterisation of industrially used African and Australian bauxites and their red mud tailings  

International Nuclear Information System (INIS)

From their genesis by weathering and sedimentation, bauxites, the principal aluminium ores, contain appreciable amounts of uranium and thorium. High resolution gamma spectrometry with a high purity germanium detector was used for an analysis of four industrially used bauxites from Gondama, Sierra Leone; Boke, Guinea; Weipa, Queensland, Australia; Gove, Northern Territory, Australia. Significant differences in uranium to thorium ratios and in activities of the uranium and thorium daughters were observed for the four bauxites. It was found that the bauxite from Gondama, Sierra Leone has an activity of only 10% compared with the others. Red mud tailings from such a bauxite may well be used as an additive to bricks, which is now illegal for normal red mud from more active bauxites. (author).

104

Thermoelectrically cooled water trap  

Energy Technology Data Exchange (ETDEWEB)

A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.

2006-02-21

105

Development and validation of a reference measurement procedure for certification of phenytoin, phenobarbital, lamotrigine, and topiramate in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Phenytoin (PHT), phenobarbital (PHB), lamotrigine (LTG), and topiramate (TPM) are some of the most widely used antiepileptic drugs (AEDs). Monitoring of their concentrations in serum is important for the treatment of epilepsy. A reference measurement procedure (RMP) for certification of PHT, PHB, LTG, and TPM in serum has been developed and critically evaluated. Isotopically labeled compounds of PHT, PHB, LTG, and TPM are used as internal standards for the four AEDs. The four drugs and their respective labeled internal standards are simultaneously extracted from serum using solid-phase extraction prior to reversed-phase liquid chromatography?tandem mass spectrometry (LC-MS/MS). Chromatographic separation was performed using a C18 column. Electrospray ionization (ESI) in the positive ion mo...

2011-01-01

106

Detection of previous neutron irradiation and reprocessing of uranium materials for nuclear forensic purposes  

International Nuclear Information System (INIS)

The paper describes novel analytical methods developed for the detection of previous neutron irradiation and reprocessing of illicit nuclear materials, which is an important characteristic of nuclear materials of unknown origin in nuclear forensics. Alpha spectrometry and inductively coupled plasma sector-field mass spectrometry (ICP-SFMS) using solution nebulization and direct, quasi-non-destructive laser ablation as sample introduction were applied for the measurement of trace-level "2"3"2U, "2"3"6U and plutonium isotopes deriving from previous neutron irradiation of uranium-containing nuclear materials. The measured radionuclides and isotope ratios give important information on the raw material used for fuel production and enable confirm the supposed provenance of illicit nuclear material.

2009-04-01

107

Gamma heating in LMFBR media  

International Nuclear Information System (INIS)

State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method was developed to permit rapid, accurate ...

1976-01-01

108

Trace elements and radioactivity measurements in some terrestrial food crops in Jos-plateau, north central, Nigeria; Elements traces et mesures de la radioactivite dans quelques recoltes vivrieres terrestres du plateau de Jos dans le centre-nord du Nigeria  

Energy Technology Data Exchange (ETDEWEB)

Some crops of important nutritive requirements have been collected from farmlands located in Bitsichi an old tin mining town in north central region of Nigeria. The food crops were analyzed in order to determine trace element concentrations level using Neutron Activation Analysis (NAA). The activity concentrations due to natural radionuclides in the food samples and soil samples collected within the root zone of the crops were also determined using gamma-ray spectrometry (GRS). The NAA results obtained showed higher concentration of Potassium among the essential elements in all the crops. Calcium concentration in both maize and Guinea corn was below detection limit and also Zn in Green beans, sweet potato and cassava. The trace elements; Sc, Hf, Sm, and Th, were below detection limit in all the crops except in Green beans. Rubidium (Rb) and lanthanum (La) were below detection limits only in Cabbage. The activity concentrations of the natural ...

2007-01-15

109

Trace elements and radioactivity measurements in some terrestrial food crops in Jos-plateau, north central, Nigeria  

International Nuclear Information System (INIS)

Some crops of important nutritive requirements have been collected from farmlands located in Bitsichi an old tin mining town in north central region of Nigeria. The food crops were analyzed in order to determine trace element concentrations level using Neutron Activation Analysis (NAA). The activity concentrations due to natural radionuclides in the food samples and soil samples collected within the root zone of the crops were also determined using gamma-ray spectrometry (GRS). The NAA results obtained showed higher concentration of Potassium among the essential elements in all the crops. Calcium concentration in both maize and Guinea corn was below detection limit and also Zn in Green beans, sweet potato and cassava. The trace elements; Sc, Hf, Sm, and Th, were below detection limit in all the crops except in Green beans. Rubidium (Rb) and lanthanum (La) were below detection limits only in Cabbage. The activity concentrations of the natural ...

110

[sup 3]He([ital n],[gamma])[sup 4]He cross section and the photodisintegration of [sup 4]He  

Energy Technology Data Exchange (ETDEWEB)

The absolute cross section of the [sup 3]He([ital n],[gamma])[sup 4]He reaction was measured at five energies between [ital E][sub [ital n

1993-11-01

112

CP Violation with Bs -> J/Psi phi at the Tevatron  

CERN Document Server

Recent results using B_s -> J/Psi phi decays for measuring the CP violating phase, phi_s, and the decay width difference for the two mass eigenstates, Delta Gamma_s, are presented from the CDF and D0 experiments at the Fermilab Tevatron collider.

2011-01-01

113

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01

114

Production of scalar Higgs and pseudoscalar Higgs in multi-Higgs doublet models at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process {gamma}{gamma}{yields}tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future {gamma}{gamma} colliders for small values of tan {beta}. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)

2000-05-01

115

Production of scalar Higgs and pseudoscalar Higgs in multi-Higgs doublet models at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process #gamma##gamma##->#tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future #gamma##gamma# colliders for small values of tan #beta#. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)

2000-05-01

116

In-beam spectroscopy of nuclei  

International Nuclear Information System (INIS)

The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).

1982-01-01

117

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, ...

2010-01-01

118

FFTF reactor-characterization program: gamma-ray measurements and shield characterization  

Science.gov (United States)

A series of experiments is to be made during the acceptance test program of the Fast Flux Test Facility (FFTF) to measure the gamma ray characteristics of the Fast Test Reactor (FTR) and to establish the performance characteristics of the reactor shield. These measurements are a part of the FFTF Reactor Characterization Program (RCP). Detailed plans have been developed for these experiments. During the initial phase of the Characteristics Program, which will be carried out in the In-Reactor Thimble (IRT), both active and passive measurement methods will be employed to obtain as much information concerning the gamma ray environment as is practical. More limited active gamma ray measurements also will be made in the Vibration Open Test Assembly (VOTA).

119

Activities and activity ratios of U and Ra radioisotopes in drinking wells, springs and tap water samples in Morocco  

International Nuclear Information System (INIS)

Radiochemical results ("2"3"4U, "2"3"8U, "2"2"6Ra and "2"2"8Ra activities; "2"3"4U/"2"3"8U, "2"2"8Ra/"2"2"6Ra and "2"2"6Ra/"2"3"8U activity ratios) are reported for 31 drinking water samples collected from 8 wells, 12 hot mineral springs, 5 cold springs, and 6 tap water samples. Activities of the Ra isotopes were measured by gamma spectrometry using a low background and high efficiency well type germanium detector. The U isotopes were counted in an alpha spectrometer. The results show that "2"3"8U activity varies between 4.46 and about 308 mBq l"-"1 in wells, 0.59 and 17.88 mBq l"-"1 in hot springs, 2.19 and 3.21 mBq l"-"1 in cold springs, and between 2.5 and 15.70 mBq l"-"1 in tap water samples. "2"3"4U/"2"3"8U activity ratio is generally higher than 1 which is the equilibrium activity ratio value in closed systems. It varies in the ranges 0.79-2.11 in wells, 0.97-7.39 in hot springs, 2.53-8.30 in cold springs, and ...

120

Improved understanding of atmospheric organic aerosols via innovations in soft ionization aerosol mass spectrometry.  

Science.gov (United States)

Organic molecules are a significant and highly varied component of atmospheric aerosols. Measurement of aerosol composition and improvements in our understanding of the complex chemistry involved in their formation and aging are being aided by innovations in soft ionization aerosol MS. (To listen to a podcast about this feature, please go to the Analytical Chemistry multimedia page at pubs.acs.org/page/ancham/audio/index.html.). PMID:21275431

2011-01-24

121

Distribution of Indole-3-Acetic Acid and the Occurrence of Its Alkali-Labile Conjugates in the Extraxylary Region of Pinus sylvestris Stems 1  

UK PubMed Central (United Kingdom)

Free and conjugated indole-3-acetic acid (IAA) were measured by quantitative gas chromatography-selected ion monitoringmass spectrometry in the extraxylary region of the stem of large Pinus...Full Text Available

1990-08-01

122

Photoelectron resonance capture ionization mass spectrometry of fatty acids in olive oil  

British Library Electronic Table of Contents (United Kingdom)

Photoelectron resonance capture ionization (PERCI) mass spectrometry has been developed for the direct online analysis of organics, including lipids. Analysis is conducted without the need for sample preparation or chemical derivatization such as methylation, foregoing the use of harmful or toxic chemicals. PERCI is currently being adapted towards the analysis of edible oils. Herein, as a proof of principle of the simplicity and potential utility of this method towards the analysis of edible oils, we present the analysis of the prevalent fatty acids (FA) in Tuscan extra-virgin olive oil along with triolein and linolenic acid (LNA) standards. Ionization of olive oil results in little fragmentation of the prevalent FA, which are measured as their molecular ions, [FA-H]-. The relative concent...

2006-01-01

123

Gas chromatography - mass-spectrometry of volatiles released from plastics used as building materials  

Energy Technology Data Exchange (ETDEWEB)

The possibility of employing a number of adsorbents (polyphenylquinoxaline, Tenax GC, Carbopak C, graphitized thermal carbon black, silica gels modified with pyrocarbon or hexamethyldisilazane) for the trapping of organic traces from air has been investigated. Adsorption capacities of these adsorbents with respect to a number of volatiles released from certain plastics used as building material (polyvinylchloride, Relin, Acronal, etc.) have been measured. A number of the volatiles were identified by gas chromatography - mass-spectrometry after trapping on the adsorbents investigated. Chromatographic separation after trapping on the adsorbents was carried out on wall-coated open-tubular capillary columns as well as in capillary columns packed with graphitized thermal carbon black.

1983-10-01

124

Direct observation of polymerization in the oleic acid-ozone heterogeneous reaction system by photoelectron resonance capture ionization aerosol mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

High molecular weight products of the ozonolysis reaction of particle-phase 9-octadecenoic acid (oleic acid) have been studied by photoelectron resonance capture ionization (PERCI) mass spectrometry (MS). Oleic acid particles ( Formula Not Shown , Formula Not Shown ) were reacted with ozone (1.8x10-4atm) in a flow reactor at reaction times of 8 and 23s. Particles were sampled on-line with a differentially pumped particle inlet and chemically analyzed by PERCI-MS. PERCI is a soft ionization method that permits the direct measurement of relatively high molecular weight compounds, facilitating molecular identification. In addition to cyclic oxygenates, such as secondary ozonides and geminal diperoxides that were reported previously, we demonstrate the formation of polymers at the particle sur...

2006-01-01

125

Dating Studies of Elephant Tusks Using Accelerator Mass Spectrometry  

Energy Technology Data Exchange (ETDEWEB)

A new method for determining the year of birth, the year of death, and hence, the age at death, of post-bomb and recently deceased elephants has been developed. The technique is based on Accelerator Mass Spectrometry radiocarbon analyses of small-sized samples extracted from along the length of a ge-line of an elephant tusk. The measured radiocarbon concentrations in the samples from a tusk can be compared to the {sup 14}C atmospheric bomb-pulse curve to derive the growth years of the initial and final samples from the tusk. Initial data from the application of this method to two tusks will be presented. Potentially, the method may play a significant role in wildlife management practices of African national parks. Additionally, the method may contribute to the underpinnings of efforts to define new international trade regulations, which could, in effect, decrease poaching and the killing of very young animals.

2002-10-03

127

Matrix-assisted laser desorption fourier transform mass spectrometry for biological compounds  

Science.gov (United States)

The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by the matrix-assisted ...

1990-01-01

129

Measurements of radioactivity in Jamaican building materials and gamma dose equivalents in a prototype red mud house  

International Nuclear Information System (INIS)

Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.

130

Estimation of gamma-absorption method for measurement of layers thickness in multi-layers articles  

International Nuclear Information System (INIS)

Certain problems of gamma-absorption method of measuring the thickness of layers in multi-layer items are analyzed. Two examples of solving the above-mentioned problems have been considered. One of them deals with a two-layer item, its integral thickness being known or measured in advance, the second example is referred to a two-layer item with unknown integral value

131

Strengh functions of strontium 88 obtained from the analysis of the (#gamma#,n) reaction near the threshold  

International Nuclear Information System (INIS)

The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.

1987-09-14

132

Search for anisotropy in the L x-gamma angular correlations following the decay of "2"0"7Bi  

International Nuclear Information System (INIS)

An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).

133

IMEF gamma scanning system  

International Nuclear Information System (INIS)

The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

1989-09-10

134

Extraction of Kaon Formfactors from K->mu nu gamma Decay at ISTRA+ Setup  

CERN Document Server

The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).

2010-01-01

135

Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.

136

Effect of X- and gamma-rays on phenolic compounds from Maytenus aquifolium Martius  

International Nuclear Information System (INIS)

The effect of irradiation using several doses of X- and #gamma#-rays (10, 20, 40, 60, 80 and 100 kGy), upon total phenolic compounds contained in the leaves of Maytenus aquifolium Martius (Celastraceae) 'espinheira santa', was investigated. The content of phenolic compounds (measured by the Folin-Denis spectrophotometric method) was unaffected by X- or #gamma#-ray irradiation, at any dose. (author)

2005-06-01

137

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute ...

2001-05-01

138

Neutron and gamma-ray penetrations in thick iron  

Energy Technology Data Exchange (ETDEWEB)

Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron ...

1980-03-01

139

The supersymmetric quantum effects at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at {gamma}{gamma} colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R{sub p}-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)

2001-08-01

140

The supersymmetric quantum effects at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at #gamma##gamma# colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R_p-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)

2001-08-01

141

Production and evaluation of labeled bisphosphonates with 153Sm, 166Ho and 177Lu as therapeutic radiopharmaceuticals  

International Nuclear Information System (INIS)

Aim: Compounds such "9"9"mTc-MDP and "9"9"mTc-HEDP are used regularly in bone scintigraphy for metastasis detection. The therapeutics properties of beta emitter radionuclides like "1"5"3Sm, "1"6"6Ho and "1"7"7Lu has been widely reported in literature being "1"7"7Lu the less developed for medical applications. With the purpose of study different radiopharmaceuticals alternatives, for metastasis bone palliation, we have evaluated, on a comparative basis, the labeling of "1"5"3Sm-MDP, "1"5"3Sm-HEDP, "1"6"6Ho-MDP, "1"6"6Ho-HEDP, "1"7"7Lu-MDP and "1"7"7Lu-HEDP from the exhibited radionuclidic purity and biological distribution point of view. Material and Methods: The radionuclides were produced at La Reina Research Reactor, Chilean Nuclear Energy Commission. The radionuclidic purity was determined by gamma-Ray spectrometry. The labeling was accomplished with MDP (Plenum) and HEDP synthesized in-house. The in-vitro affinity of labeled compounds to ...

2002-09-01

142

Isolation and determination of {sup 90}Sr, {sup 226}Ra, {sup 228}Ra and {sup 210}Pb in food; Abtrennung und Bestimmung von {sup 90}Sr, {sup 226}Ra, {sup 228}Ra und {sup 210}Pb in Lebensmitteln mittels eines Strontium-spezifischen Extraktionsharzes  

Energy Technology Data Exchange (ETDEWEB)

A procedure is described for the isolation and determination of {sup 90}Sr, {sup 226}Ra, {sup 228}Ra and {sup 210}Pb in food. These nuclides are highly radiotoxic, above all for babies and children. Samples are dry ashed, alkali metals are removed as carbonates. Separation from other matrix ions and separation of Ra, Sr and Pb can be achieved with a column of Sr-Spec, an immobilized crown ether. For activity measurements membrane filters with SrSO{sub 4}, Ba(Ra)SO{sub 4} and PbS are prepared. Ra is determined by gamma-spectrometry, {sup 90}Sr and {sup 210}Pb are determined by low-level-betacounting. The determination limits are 10 mBq/kg for {sup 90}Sr and {sup 210}Pb and 50 mBq/kg for {sup 226}Ra and {sup 228}Ra. The procedure is useful for all kinds of foodstuff. (orig.) [Deutsch] Es wird ein Analysengang zur Abtrennung und Bestimmung von {sup 90}Sr, {sup 226}Ra, {sup 228}Ra und {sup 210}Pb in Lebensmitteln beschrieben. Ein Merkmal dieser ...

1996-12-31

143

Analysis of Elements in The Baltic Sea Sediment by Using Gamma Spectrometry  

International Nuclear Information System (INIS)

We have done analysis of elements in the Baltic sea sediment by using gamma spectrometry in neutron activation analysis Goal of the analysis is to determine the rate of morsel elements which is contained in the Baltic sea sediment. Sample of the Baltic sea Sediment (IAEA-SED-1), Standard of Reference Material (SRM) 1646 Estuarine Sediment and Standard Ce, Fe, Sc, and Co are put into vial of capsule rabbit, then irradiated together for 30 minutes in rabbit facility Multi Purpose Reactor at power of 25 MW and then cooled for one week. Next sample, standard, and SRM which have irradiated, each is cut for 30 minutes using gamma spectrometer. Result of analysis of rate of elements Ce, Fe, Sc and Co in the baltic sea sediment successively equal to 141.20 ppm, 5.91 %, 14.88 ppm, and 19.59 ppm. Result of analysis in SRM Estuarine sediment successively equal to 96.60 ppm, 3.21 %, 10.25 ppm, and 9.63 ppm. Result of this analysis if ...

2007-04-01

147

Higgs, SUSY and the standard model at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

In this report, I surveyed physics potential of the {gamma}{gamma} option of a linear e{sup +}e{sup -} collider with the following questions in mind: What new discovery can be expected at a {gamma}{gamma} collider in addition to what will be learned at its 'parent' e{sup +}e{sup -} linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e{sup -} beams, we find that a {gamma}{gamma} collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e{sup -}e{sup -} system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a {gamma}{gamma} collider. CP property ...

2001-10-11

148

Higgs, SUSY and the standard model at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

In this report, I surveyed physics potential of the #gamma##gamma# option of a linear e"+e"- collider with the following questions in mind: What new discovery can be expected at a #gamma##gamma# collider in addition to what will be learned at its 'parent' e"+e"- linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e"- beams, we find that a #gamma##gamma# collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e"-e"- system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a #gamma##gamma# collider. CP property of the scalar sector can be explored in detail by ...

2001-10-11

149

Measurement of the photon-proton total cross section at a center-of-mass energy of 209 GeV at HERA  

Energy Technology Data Exchange (ETDEWEB)

The photon-proton total cross section has been measured in the process e{sup +}p{yields}e{sup +}{gamma}p{yields}e{sup +}X with the ZEUS detector at HERA. Events were collected with photon virtuality Q{sup 2}<0.02 GeV{sup 2} and average {gamma}p center-of-mass energy W{sub {gamma}}{sub p}=209 GeV in a dedicated run, designed to control systematic effects, with an integrated luminosity of 49 nb{sup -1}. The measured total cross section is {sigma}{sub tot}{sup {gamma}}{sup p}=174{+-}1 (stat.){+-}13 (syst.) {mu}b. The energy dependence of the cross section is compatible with parameterizations of high-energy pp and pp-bar data.

2002-04-15

150

Study of some Ayurvedic Indian medicinal plants for the essential trace elemental contents by instrumental neutron activation analysis and atomic absorption spectroscopy techniques  

Energy Technology Data Exchange (ETDEWEB)

Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)

2009-07-01

151

LLX separation of carrier-free {sup 47}Sc, {sup 48}V and {sup 48,49,51}Cr produced in {alpha}-particle activated titanium with HDEHP  

Energy Technology Data Exchange (ETDEWEB)

A LLX procedure for carrier-free separation of the radioisotopes, {sup 47}Sc, {sup 48}V and {sup 48},{sup 49},{sup 51}Cr, the 40 MeV {alpha}-particle activation products of titanium has been developed. Sequential separations of the radionuclides produced in the titanium matrix through the nuclear reactions ({alpha}, {alpha}p{chi}n), ({alpha}, p{chi}n) and {alpha}, ({chi}n) have been performed through LLX from aqueous H{sub 2}SO{sub 4} and HClO{sub 4} acid media using the liquid cation exchanger, HDEHP, as an extractant. Purity of the carrier-free radiotracers at different stages of their separations has been verified by {gamma}-ray spectrometry. (author).

1996-01-01

152

Excitation functions and yields of the (d,p) reactions on natural molybdenum for deuteron energies less than 13 MeV  

International Nuclear Information System (INIS)

The excitation functions of the reactions "9"8Mo(d,p)"9"9Mo and "1"0"0Mo(d,p)"1"0"1Mo have been determined by irradiation of stacked foils with deuterons of energies less than 13 MeV and non-destructive determination of the absolute activity of the Mo radioisotopes by semiconductor #gamma#-ray spectrometry. From the excitation functions, the thick-target yields and the saturation production rates of "9"9Mo and "1"0"1Mo for deuteron energies of 13.0 MeV and 11.7 MeV have been calculated. Implications for the production of "9"9Mo for generators of sup(99m)Tc are discussed. (author).

153

Determination of macro, micro nutrient and trace element concentrations in Indian medicinal and vegetable leaves using instrumental neutron activation analysis  

Energy Technology Data Exchange (ETDEWEB)

Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.

1999-05-01

154

Carbon-12 induced fission of "2"0"9Bi at 84.2 MeV  

International Nuclear Information System (INIS)

The "1"2C induced fission of "2"0"9Bi at particle energy of 84.2 MeV has been studied using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The charge distribution has also been studied and the relative fractional cumulative yields of "9"2Y, "9"7Zr, "9"9Mo, "1"0"1Mo, "1"0"5Rh, "1"1"2Pd and "1"1"7"mCd determined. The yield distribution of fission products has been found to be broad (FWHM #approx =# 18) with a peak near mass #approx =# 105. (author). 7 refs., 2 tabs.

155

Availability of essential trace elements in Ayurvedic Indian medicinal herbs using instrumental neutron activation analysis  

Energy Technology Data Exchange (ETDEWEB)

Specific parts of several plants (fruits, leaves, stem, bark and roots) often used as medicines in the Indian Ayurvedic system have been analysed for 20 elements (As, Ba, Br, Ca, Cl, Co, Cr, Cu, Fe, K, Mn, Mo, Na, P, Rb, Sb, Sc, Se, Sr and Zn) by employing instrumental neutron activation analysis (INAA). The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted using high resolution gamma ray spectrometry. Most of the medicinal herbs have been found to be rich in one or more of the elements under study. (Author).

1997-01-01

156

Contamination by depleted uranium (Du) in South Serbia  

Energy Technology Data Exchange (ETDEWEB)

The paper present the results of the study on D.U. (depleted uranium) contamination in the environment and possible effects on animal healths in the region o f Bujanovac. Samples of soil, feed, leaves, grass, lichen, moss, honey and water were collected randomly in 2003/2004 in the vicinity of the target area (500-1000 m) and 5 km from the target area. Activity of the radionuclides ({sup 226}Ra, {sup 232}Th, {sup 40}K, {sup 210}Pb, {sup 238}U, {sup 235}U, {sup 137}Cs, {sup 7}Be) in soils, grass, lichen, moss and honey was determined on Hp Ge detector (Canberra, relative efficiency 23%) by standard gamma spectrometry. Total alpha and beta activity in water was determined on proportional alpha/beta counter (Canberra 2400, efficiency for alpha emitters 11%, efficiency for beta emitters 30%). Non significantly higher values of concentrations of {sup 226}Ra, {sup 232}Th, {sup 238}U and {sup 235}U were measured in the immediate ...

2006-07-01

157

Thyroidal uptake of iodine-123 in children using a gamma camera and computer  

Energy Technology Data Exchange (ETDEWEB)

The measurement of thyroidal uptake of radioiodine using a gamma camera and computer is described. In 12 children there was good agreement with simultaneous measurements using a probe, while in a further 14 patients the uptake values were consistent with the clinical diagnosis. The technique should be especially useful for infants and small children.

1985-10-01

158

Gamma absorption determination of concentration in a three-component mixture  

International Nuclear Information System (INIS)

A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.

159

Determining the upper limit of Gamma_{ee} for the Y(4260)  

CERN Document Server

By fitting the R values between 3.7 and 5.0 GeV measured by the BES collaboration, the upper limit of the electron width of the newly discovered resonance Y(4260) is determined to be 240 eV at 90% C.L., together with the BABAR measurement on the product of Gamma_{ee} and BR(Y(4260) --> pi+pi- J/psi), this implies a large decay width of Y(4260) --> pi+pi- J/psi final states.

2006-01-01

160

Design concept and testing of an in-bundle gamma densitometer for subchannel void fraction measurements in the THTF electrically heated rod bundle  

International Nuclear Information System (INIS)

A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.

161

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer ...

1997-05-01

162

Semileptonic b to u transition  

CERN Document Server

Experimental studies of charmless semileptonic B decays can be broadly categorized into inclusive and exclusive measurements depending on how the final states are treated. The inclusive method measures the decay rate $\\Gamma(B \\to X_u \\ell \

2007-01-01

163

Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. I. Test series through HARDTACK II, 1958  

Energy Technology Data Exchange (ETDEWEB)

In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite ...

1985-12-01

164

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning ...

2009-03-01

165

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning ...

2007-06-15

166

Forthcoming (n, #gamma#) measurements on the Fe and Ni isotopes at CERN n_TOF  

International Nuclear Information System (INIS)

An overview of the past, present and future research activities at the CERN neutron time of flight facility n_TOF is given, with special focus on the astrophysical aspects. During the first campaign (Phase I), neutron capture cross sections of relevance for several aspects of the s-process nucleosynthesis have been measured. A second campaign has recently started (Phase II), aiming at the study of the weak s-process component via accurate (n,#gamma#) measurements of the Fe and Ni isotopes. Some changes in the facility will allow us to perform these measurements with improved experimental conditions.

2010-01-01

167

RESUME-95: Results of an International Field Test of Mobile Equipment for Emergency Response  

DEFF Research Database (Denmark)

In 1995 the exercise RESUME-95 (Rapid Environmental Surveying Using Mobile Equipment) took place in Finland. Groups from 8 European countries joined the exercise. The methods used were airborne gamma-ray measurements, car-borne measurements and in situ stationary measurements. The results of the measurements are analyses aiming at disclosing similarities and differences between groups and measuring techniques.

1997-01-01

168

Study on the stability of the Maytenus aquifolium Martius chemical components submitted to ionizing radiation (X-ray and #gamma#)  

International Nuclear Information System (INIS)

The interest for medicinal plants has raised again in the last decades, after overcoming a declination period caused by the advances in the researches and development of the synthetic drugs industries. This growing interest has been stimulated mainly by searching cheap and accessible alternative therapies. However, in order to have natural products based treatment in an efficient and safety way, it is necessary to guarantee the plant authenticity, finding adulterations and to assure a low level of microbiological contaminations to avoid damages to consumer's health. The decontamination method should be chosen for eliminating or reduce the microorganisms level without loss of the plant active constituents that would destroy its therapeutic action. At the present work, the possibility of using #gamma# and X electromagnetic radiations to sterilize a Brazilian medicinal plant (Maytenus aquifolium Martius, Celastraceae), which shows anti-ulcer activity, was studied by ...

170

Soil heterogeneity effects on O2 distribution and CH4 emissions from wetlands: In situ and mesocosm studies with planar O2 optodes and membrane inlet mass spectrometry  

British Library Electronic Table of Contents (United Kingdom)

The importance of soil heterogeneity for methane emission from a wetland soil is assessed by in situ point measurements of depth-specific O2 and CH4 concentrations and simultaneous soil CH4 fluxes at contrasting water levels. Profile measurements, and associated assumptions in their interpretation, were validated in a controlled mesocosm drainage and saturation experiment applying planar O2 optodes and membrane inlet mass spectrometry. Results show that peat soil is heterogeneous containing dynamic macropore systems created by both macrofauna and flora, which facilitate preferential flow of water, O2 and CH4 and vary temporally with changes in the moisture regime. The O2 content above the water table after drainage varied horizontally from 0 to 100% air saturation within few mm. Oxic zones...

2010-01-01

171

Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning  

International Nuclear Information System (INIS)

The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).

172

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The ...

2007-03-15

173

Measurement of the triple gauge-boson couplings {gamma}WW and ZWW in ALEPH and at LEP; Mesure des couplages {gamma}WW et ZWW dans ALEPH et au LEP  

Energy Technology Data Exchange (ETDEWEB)

This document deals with the couplings between the W boson and Z and gamma particles. WWZ and WW{gamma} vertex are predicted by the electroweak theory based on the symmetry group SU(2){sub L}*U(1){sub Y}, their existence is confirmed by the measurement of the production cross-section of W pairs at LEP. The effective values of the couplings are modified by the introduction of standard model particle loops at the vertex level, the impact on the coupling value is assessed to reach 10{sup -3}. These loops can also include beyond-the-standard-model particles, their impact is in the magnitude order of 10{sup -3} for most models. The fully description of these loops requires the values of 14 complex parameters whose measurement will give information about the existence of new particles. Nevertheless the number of events at LEP is not sufficient to measure all the parameters simultaneously. ...

2005-03-15

174

Burnup determination of spent nuclear fuel in the pool  

Energy Technology Data Exchange (ETDEWEB)

A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in ...

1998-06-01

175

The use of lead isotopic abundances in trace uranium samples for nuclear forensics analysis  

International Nuclear Information System (INIS)

Secondary ion mass spectrometry (SIMS), secondary electron microscopy (SEM) and X-ray analysis have been applied to the measurement of U-bearing particles with the intent of gleaning information concerning their history and/or origin. The lead isotopic abundances are definitive indicators that U-bearing particles have come from an ore-body, even if they have undergone chemical processing. SEM images and X-ray analysis can add further information to the study that may allude to the extent of chemical processing. The presence of 'common' lead that does not exhibit a radiogenic signature is clear evidence of anthropogenic origin. (author)

2010-06-01

176

RBS Characterization of Yttrium Iron Garnet Thin Films  

International Nuclear Information System (INIS)

Magnetic materials such as yttrium iron garnet (YIG) are of great importance for its magneto-optic properties and for their potential applications in the domain of optical telecommunications. The deposition of thin films of YIG, on quartz or GGG (gadolinium gallium garnet) substrate, was performed using radio frequency non reactive magnetron sputtering, followed by high temperature annealing which is needed to enhance the crystallinity of the layers. Rutherford backscattering spectrometry RBS was used to determine the thickness and stoichiometry of the performed layers in order to investigate correlations between growth conditions and the quality of the final material. RBS measurements showed the influence of the deposition time and the temperature substrate on the film growth and its stoichiometry. (author)

2008-12-13

177

Post-mortem measurements of fuel retention at JET with MKII-SRP divertor  

International Nuclear Information System (INIS)

The deuterium inventory at JET after 2001-2004 operational campaign has been determined using nuclear reaction analysis (NRA) and secondary ion mass spectrometry (SIMS). A full poloidal set of divertor tiles and a set of outer poloidal limiter (OPL) tiles were analysed providing an estimation for the total deuterium retention of about 66 g. Deuterium is trapped mainly at the inner divertor on horizontal target tile and at the inner divertor louvre area where ?60% of the trapped D is found. The long-term D retention is ?4% of the total D input.

2009-06-15

178

Nuclear material accountability by isotope dilution mass spectrometry  

International Nuclear Information System (INIS)

This paper discusses the mass spectrometric system that has been developed at the ICPP (Idaho Chemical Processing Plant) to meet the multiple constraints of U accountability, high sample load, and plant process control. The measurement system must produce high-quality accountability results while maintaining high sample throughput and reasonable turnaround time. The mass spectrometric system that has evolved to meet these demands includes extensive operator training, routine quality control checks, and continuing review of performance. 7 refs.

1981-07-13

179

Multielement analysis of air samples  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A "2"3"8Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed. (author).

1981-01-01

180

Inf-convolution of g_\\Gamma-solution and its applications  

CERN Document Server

A risk-neutral method is always used to price and hedge contingent claims in complete market, but another method based on utility maximization or risk minimization is wildly used in more general case. One can find all kinds of special risk measure in literature. In this paper, instead of using market modified risk measure, we use a kind of risk measure induced by g_\\Gamma-solution or the minimal solution of a Constrained Backward Stochastic Differential Equation (CBSDE) directly when constraints on wealth and portfolio process comes to our consideration. Such g_\\Gamma-solution and the risk measure generated by it is well defined on appropriate space under suitable conditions. We adopt the inf-convolution of convex risk measures to solve some optimization problem. A dynamic version risk measures defined through ...

2011-01-01

181

Kaluza-Klein Effects on Higgs Physics in Universal Extra Dimensions  

Energy Technology Data Exchange (ETDEWEB)

We examine the virtual effects of Kaluza-Klein (KK) states on Higgs physics in universal extra dimension models. We study the partial widths {Lambda}{sub h{yields}gg}, {Lambda}{sub h{yields}{gamma}{gamma}}, and {Lambda}{sub h{yields}{gamma}Z}, which are relevant for Higgs production and detection in future collider experiments. These interactions occur at one loop in the Standard Model, as do the KK contributions. We find that the deviations induced by the KK exchanges can be significant; for one extra dimension, the gg {yields} h production rate is increased by 10% - 85% for the mass of the first KK state in the range 500 {approx}> m{sub 1} {approx}> 1500 GeV, a region untested by current direct search and precision measurement constraints. The h {yields} {gamma}{gamma} decay width is decreased by {approx}< 20% in the same mass range. For two or more universal extra dimensions the ...

2002-04-05

182

Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02  

Energy Technology Data Exchange (ETDEWEB)

Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from ...

2004-12-15

183

A Measurement of the Spatial Distribution of Diffuse TeV Gamma Ray Emission from the Galactic Plane with Milagro  

Energy Technology Data Exchange (ETDEWEB)

Diffuse {gamma}-ray emission produced by the interaction of cosmic-ray particles with matter and radiation in the Galaxy can be used to probe the distribution of cosmic rays and their sources in different regions of the Galaxy. With its large field of view and long observation time, the Milagro Gamma Ray Observatory is an ideal instrument for surveying large regions of the Northern Hemisphere sky and for detecting diffuse {gamma}-ray emission at very high energies. Here, the spatial distribution and the flux of the diffuse {gamma}-ray emission in the TeV energy range with a median energy of 15 TeV for Galactic longitudes between 30{sup o} and 110{sup o} and between 136{sup o} and 216{sup o} and for Galactic latitudes between -10{sup o} and 10{sup o} are determined. The measured fluxes are consistent with predictions of the GALPROP model everywhere except for the Cygnus region (l ...

2008-05-14

184

Characterization of an improved disposal site for low and intermediate level waste using Cs-137 deposition profiles  

International Nuclear Information System (INIS)

According to the present concept, the low and intermediate level wastes generated during the Cernavoda NPP operation will be disposed in a near surface repository. The Saligny site, placed in the NPP protected area, has been proposed for their disposal. Geologically, the main components of this site are the quaternary loess, the Precambrian and Pre-quaternary clays, the Eocene and Barremian limestone. Hydrologically, the site can be divided into a vadose zone down to 45-50 m and three distinct aquifers, two of them in the limestone beds and the third in the lenses of sand and limestone existing in the pre-quaternary clay layer. A large research program for site characterization was initiated in 1996. At present, the site characteristics requested for safety analysis have been experimentally measured on soil samples or calculated by different computer programs. Hundreds of experimental values of the density, porosity, hydraulic conductivity, soil-water retention, ...

2004-09-09

185

Tritium monitor with improved gamma-ray discrimination  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.

1985-01-01

186

Parity nonconservation in "2"0"7Pb  

International Nuclear Information System (INIS)

Two experiments are currently underway to measure the single-particle weak mixing matrix element for the 1064 KeV transition in "2"0"7Pb. One experiment measures the circular polarization of the 1064 KeV gamma ray emitted from an unpolarized source, while the other experiment measures the forward-backward asymmetry of gamma rays emitted from a polarized source. Analysis of the first set of polarized source data yields an upper limit of 46 eV for the single-particle weak mixing matrix element. copyright 1995 American Institute of Physics.

187

Choice of distance from radiation source to tested object for gamma-absorption density measurer in divergent pencil of ray  

International Nuclear Information System (INIS)

Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage

188

Power density distribution by gamma scanning of fuel rods measurement technique in RA-8 critical facility  

International Nuclear Information System (INIS)

Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)

1999-10-26

189

Investigation of the "1"0"1Mo level and gamma-decay scheme by thermal neutron capture in "1"0"0Mo  

International Nuclear Information System (INIS)

The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).

1975-03-01

190

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

191

Measurement of the parity violating asymmetry A{sub {gamma}} in n{yields}+p{yields}d+{gamma}  

Energy Technology Data Exchange (ETDEWEB)

The weak interaction between neutrons and protons has never been resolved experimentally. In analogy with the strong NN interaction, the weak NN interaction at low energy can be parametrized in terms of a meson exchange model with parity violating meson-nucleon couplings. Unlike the measured proton-proton weak interaction, the neutron-proton weak interaction is sensitive to the weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. This coupling, which is responsible for the longest-ranged part of the weak NN interaction and is therefore an essential part of any description of weak interactions in nuclei, remains undetermined despite many years of effort. A measurement of the gamma ray directional asymmetry A{sub {gamma}} in the capture of polarized neutrons by parahydrogen has been proposed at Los Alamos National Laboratory. The goal of this experiment is to determine A{sub ...

2000-02-11

192

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning ...

193

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning ...

2007-03-15

194

Production of three vector bosons in #gamma# #gamma# colliders  

International Nuclear Information System (INIS)

The production of three vector bosons in #gamma# #gamma# collisions studying the reactions #gamma# + #gamma# #-># W"+ + W"- + Z"0 and #gamma# + #gamma# #-># W"+ + W"- + #gamma#. 12 refs., 4 figs., 2 tabs.

195

Stabilization of measuring channel of reflective gamma thickness gage by light pulses from additional scintillator  

International Nuclear Information System (INIS)

Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.

196

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

197

Mass charge and angular momentum transfer in "1"0"6Cd + 255 MeV "5"4Fe collision studied by #gamma#-#gamma# coincidences  

International Nuclear Information System (INIS)

The distribution of mass, charge and angular momentum transfer among the products of 54-Fe (255 MeV) ions collisions with the 106 Cd target have been studied. The energy level schemes for 92-Mo, 60-Ni, 96-Ru and 56-Fe are presented. The production yields of different isotopes were also measured. 1 ref., 14 figs.

1991-12-01

198

Energy dependence of the yield of fission isomers in the /sup 241/Am(n,. gamma. ) and /sup 243/Am(n,. gamma. ) reactions  

Energy Technology Data Exchange (ETDEWEB)

Ratio of the fissile isomers and prompt fissions yields has been measured in processes of neutron capture by /sup 241/Am and /sup 243/Am nuclei in the neutron energy interval from 0.2 up to 1.3 MeV. The present data and the previous results suggest that the fission Am isomers are spin structure isomers rather than shape isomers.

1984-11-01

199

Decay scheme data for [sup 101]Mo and [sup 101]Tc  

Energy Technology Data Exchange (ETDEWEB)

New measurements of relative gamma-ray emission probabilities in the decay of [sup 101]Mo and [sup 101]Tc are reported. Previously published conversion-electron data have been used along with the gamma-ray data to formulate self-consistent decay schemes. (orig.)

1993-10-01

200

Decay scheme data for "1"0"1Mo and "1"0"1Tc  

International Nuclear Information System (INIS)

New measurements of relative gamma-ray emission probabilities in the decay of "1"0"1Mo and "1"0"1Tc are reported. Previously published conversion-electron data have been used along with the gamma-ray data to formulate self-consistent decay schemes. (orig.).

201

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

202

Evaluation of the cleanliness of ultrapure water by the analysis for metal concentration deposited on Si wafer surface using vapor phase decomposition/inductively coupled plasma mass spectrometry  

International Nuclear Information System (INIS)

Along with the shrinkage of LSI geometries, a higher quality of ultrapure water has been continuously required. Analytical technology for ultrapure water has also progressed before ultrapure water production technology improvements. In this study, we performed optimization of the analytical conditions for the direct analysis of acid droplets, and established an analytical technology for measurements of trace amounts of metallic impurities deposited on a wafer surface by means of Vapor Phase Decomposition (VPD)/Inductively Coupled Plasma Mass Spectrometry (ICP-MS). As a result, analytical technology for metallic elements of the 1x10"8 atoms/cm"2 level on wafer surface has been established. By applying analytical technology to the wafer that has been contacted with ultrapure water, a new evaluation technology for ultrapure water quality by means of wafer surface contamination has been established. We confirmed good correlations between metal ...

2010-07-01

203

Direct sampling ion trap mass spectrometry (DSITMS). Innovative technology summary report  

Energy Technology Data Exchange (ETDEWEB)

This report describes the cost, performance, and other key characteristics of an innovative technology for determining the presence or absence, and measuring the concentration, of volatile organic compounds (VOCs) and semi-volatile organic compounds (SVOCs) in groundwater and soil, and in gaseous remediation process streams at hazardous waste sites. This new technology is Direct Sampling Ion Trap Mass Spectrometry (DSITMS). DSITMS introduces sample materials directly into an ion trap mass spectrometer by means of a very simple interface, such as a capillary restrictor or a polymer membrane. There is typically very little, if any, sample preparation and no chromatographic separation of the sample constituents. This means that the response of the instrument to the analytes or contaminants in a sample is nearly instantaneous, and that analytical methods based on DSITMS are fast. Analyses are typically completed in less than five minutes, and the ...

1998-12-01

204

Advanced nanoscale separations and mass spectrometry for sensitive high-throughput proteomics  

Energy Technology Data Exchange (ETDEWEB)

We review recent development in separations and mass spectrometric instrumentation for sensitive and high-throughput proteomic analyses. These efforts have been primarily focused on the development of high-efficiency (separation peak capacity of ~103) nanoscale liquid chromatography (nanoLC; e.g., flow rates extending down to ~20 nL/min at optimal separation linear velocities through narrow packed capillaries) in combination with advanced mass spectrometry (MS), including high sensitivity and high resolution Fourier transform ion cyclotron resonance (FTICR) MS. This technology enables MS analysis of low nanogram-level proteomic samples (i.e., nanoscale proteomics) with individual protein identification sensitivity at the low zeptomole-level. The resultant protein measurement dynamic range can reach 106 for nanogram-sized proteomic samples, while more abundant proteins can be detected from complex sub-picogram size proteome samples. The average ...

2005-06-01

205

Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system  

Energy Technology Data Exchange (ETDEWEB)

The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional ...

2003-05-01

206

Polymers and paper as packaging materials of irradiated food  

International Nuclear Information System (INIS)

Effects of #gamma#-irradiation on synthetic polymers and paper used as packaging materials for irradiated food have been studied by NMR. Polystyrene, polybutadiene and some copolymers were studied before and after the #gamma#-irradiation treatment and in the presence or absence of antioxidants and stabilisers. In the absence of additives, the effect of #gamma#-irradiation on polystyrene is negligible even irradiating at high doses. In turn, the role of antioxidants and stabilisers is crucial in polybutadiene and butadiene-containing copolymers. Wood pulp paper was also studied by NMR. Preliminary measurements on #gamma#-irradiated wood pulp sheets show a shortening in the T_2 relaxation time component due to the bound water, i.e. some of the bound water is lost. (author)

2000-03-01

207

Neutron star evolution and emission  

Science.gov (United States)

This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.

1997-08-01

208

Levels in sup 152 Gd and sup 152 Sm populated by the decay of sup 152 Eu  

Energy Technology Data Exchange (ETDEWEB)

The energy level schemes of {sup 152}Gd and {sup 152}Sm have been established on the basis of single gamma-spectra, and gamma-gamma coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/beta{sup +} and beta{sup -} decays of {sup 152}Eu to {sup 152}Sm and {sup 152}Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).

1990-01-01

209

Levels in "1"5"2Gd and "1"5"2Sm populated by the decay of "1"5"2Eu  

International Nuclear Information System (INIS)

The energy level schemes of "1"5"2Gd and "1"5"2Sm have been established on the basis of single #gamma#-spectra, and #gamma#-#gamma# coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/#beta#"+ and #beta#"- decays of "1"5"2Eu to "1"5"2Sm and "1"5"2Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).

1990-01-01

210

Radon emanation and soil moisture effects on airborne gamma-ray measurements  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was ...

1997-09-01

211

Radon emanation and soil moisture effects on airborne gamma-ray measurements  

International Nuclear Information System (INIS)

A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was ...

212

Potential of AMS for Quantifying Long-Lived Reaction Products  

International Nuclear Information System (INIS)

Accelerator mass spectrometry (AMS) represents a powerful technique for the detection of long-lived radionuclides through ultra-low isotope ratio measurements. In many cases, counting atoms rather than decays yields much higher sensitivities. The potential of AMS will be demonstrated on typical radionuclides of interest with half-lives between some tens of years up to a hundred million years. The precise measurement of the 27Al(n,2n)26Al excitation function will be exemplified. Lack of information exists for a list of nuclides as pointed out by nuclear data requests. A brief overview on detection limits and some applications for selected long-lived radionuclides is given.

2005-05-24

213

Width of the 1.836-MeV level in "8"8Sr  

International Nuclear Information System (INIS)

Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2"+_1 level in "8"8Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.

214

Terminal-differential algorithm for identification of local non homogeneity in article  

International Nuclear Information System (INIS)

Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study

215

Single Higgs-boson production at a photon-photon collider: general 2HDM versus MSSM  

CERN Document Server

We revisit the production of a single Higgs boson from direct \\gamma \\gamma -scattering at a photon collider. We compute the total cross section \\sigma(\\gamma \\gamma \\to h) (for h=h0, H0, A0), and the strength of the effective g_{h \\gamma \\gamma} coupling normalized to the Standard Model (SM), for both the general Two-Higgs-Doublet Model (2HDM) and the Minimal Supersymmetric Standard Model (MSSM). In both cases the predicted production rates for the CP-even (odd) states render up to 10^4 (10^3) events per 500 \\invfb of integrated luminosity, in full consistency with all the theoretical and phenomenological constraints. Depending on the channel the maximum rates can be larger or smaller than the SM expectations, but in most of the parameter space they should be well measurable. We analyze how these departures depend on the dynamics ...

2011-01-01

216

Inventory determination of low and intermediate level radioactive waste of Paks Nuclear Power Plant origin  

International Nuclear Information System (INIS)

In the execution of disposal of low and intermediate level radioactive wastes, it is important to evaluate accurately the kind and quantity of each radionuclide in the wastes. For such an evaluation, correlation of non-gamma-emitting nuclides based on gamma-emitting nuclides is recommended and regarded as a partial method. This method necessitates a completion of a highly accurate and reliable nondestructive assay system of gamma-emitting nuclides for partical use. In 1992, in support of the new waste disposal program in Hungary, Paks NPP initiated a waste characterization program to determine the radiological properties of its rad wastes. A segmented gamma scanning system has been set up to measure the gamma-emitting nuclides in 2000 litre low level drums following in-drum compaction. In the framework of the program a radiochemical analysis sub-program was ...

217

Proton-neutron interaction in odd--odd indium nuclei  

International Nuclear Information System (INIS)

Low-lying nuclear energy levels in "1"1"0In and "1"1"2In were determined from de-excitation #gamma#-rays produced with "1"0"7Ag(#alpha#,n#gamma#)-"1"1"0In, "1"0"8Pd("6Li,4n#gamma#)"1"1"0In, "1"0"9Ag(#alpha#,n#gamma#)"1"1"2In and "1"1"0Pd("6Li,4n#gamma#)"1"1"2In reactions. In addition, the "1"1"4In energy level structure was investigated with the "1"1"0Pd("7Li,3n#gamma#)"1"1"4In reaction. Properties of de-excitation #gamma#-rays were determined from #gamma#-#gamma# coincidence, excitation, and angular distribution measurements conducted with Ge(Li) and Ge(intr.) #gamma#-ray detectors. A sequence of intraconnected levels in each of "1"1"0,"1"1"2,"1"1"4In were assigned to the (#pi#g"-"1/sub 9/2/, #nu#h/sub 11/2/) configuration. For the "1"1"0,"1"1"2,"1"1"4In energy level schemes a ...

1977-01-01

218

Proton-neutron interaction in odd--odd indium nuclei  

International Nuclear Information System (INIS)

An experimental study was performed in order to study the nuclear structure in odd--odd In isotopes. Low lying nuclear energy levels in "1"1"0In and "1"1"2In were determined from de-excitation #gamma#-rays produced with "1"0"7AG(#alpha#,n#gamma#)"1"1"0In, "1"0"8Pd("6Li,4n#gamma#)"1"1"0In, "1"0"9Ag(#alpha#,n#gamma#)"1"1"2In and "1"1"0Pd("6Li,4n#gamma#)"1"1"2In reactions. In addition, the "1"1"4In energy level structure was investigated with the "1"1"0Pd("7Li,3n#gamma#)"1"1"4In reaction. Properties of de-excitation #gamma#-rays were determined from #gamma#--#gamma# coincidence excitation and angular distribution measurements conducted with Ge(Li) and Ge(intr.) #gamma#-ray detectors. A sequence of intraconnected levels in each of "1"1"0 "1"1"2 "1"1"4In were assigned to the ...

1977-01-01

219

Observation of $X(3872)\\to J/\\psi \\gamma$ and search for $X(3872)\\to\\psi'\\gamma$ in B decays  

CERN Document Server

We report a study of $B\\to (J/\\psi \\gamma) K$ and $B\\to (\\psi' \\gamma)K$ decay modes using $772\\times 10^{6}$ $B\\bar{B}$ events collected at the \\Upsilon(4S)$ resonance with the Belle detector at the KEKB energy-asymmetric $e^+ e^-$ collider. We observe $X(3872) \\to J/\\psi \\gamma$ and report the first evidence for $\\chi_{c2} \\to J/\\psi \\gamma$ in $B\\to (X_{c\\bar{c}}\\gamma) K$ decays, while in a search for $X(3872) \\to \\psi' \\gamma$ no significant signal is found. We measure the branching fractions, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) \\mathcal{B}(X(3872) \\to J/\\psi\\gamma)$ $=$ $(1.78^{+0.48}_{-0.44}\\pm 0.12)\\times 10^{-6}$, $\\mathcal{B} (B^{\\pm} \\to\\chi_{c2} K^{\\pm})$$=$ $(1.11^{+0.36}_{-0.34} \\pm 0.09) \\times 10^{-5}$, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) ...

2011-01-01

220

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas ...

2007-09-21

221

CP property of the Higgs at the #gamma##gamma# colliders using tt-bar production  

International Nuclear Information System (INIS)

We present results of an investigation to study CP violation in the Higgs sector in tt-bar production at a #gamma##gamma#-collider, via the process #gamma##gamma# #-># #phi# #-># tt-bar where the #phi# is a scalar with indeterminate CP parity. The study is performed in a model independent way parametrising the CP violating couplings in terms of six form factors #left brace#R(S_#gamma#), T(S_#gamma#), R(P_#gamma#), T(P_#gamma#), S_t, P_t#right brace#. The CP violation is reflected in the polarisation asymmetry of the produced top quark. We use the angular distribution of the decay lepton from t/t-bar as a diagnostic of this polarisation asymmetry and hence of the CP mixing, after showing that the asymmetries in the angular distribution are independent of any CP violation in the tbW vertex. We construct combined asymmetries in the initial state lepton ...

2003-09-01

222

Simultaneous measurement of the neutron capture and fission yields of "2"3"3U  

International Nuclear Information System (INIS)

We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)

2007-04-22

223

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

224

Choice of energies in gamma-absorption method for layers thickness measuring of two-layers articles  

International Nuclear Information System (INIS)

Empirical formulae are proposed for the description of relation between optimum energies minimizing the mean-weighted error of gamma absorption measurement of the thickness of layers in two-layer products with the thickness of every layer from 30 up to 150 mm by carbon. Error of informational parameter approximation with the application of tables does not exceed 10% in case of non-accurate assessment of layers thickness not exceeding 2.5%. Generalized equation is derived which binds main parameters of the task and permits to choose optimum energies with the accuracy sufficient for practical purposes

225

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

226

Achievements in testing of the MGA and FRAM isotopic software codes under the DOE/NNSA-IRSN cooperation of gamma-ray isotopic measurement systems  

Energy Technology Data Exchange (ETDEWEB)

DOE/NNSA and IRSN collaborated on a study of gamma-ray instruments and analysis methods used to perform isotopic measurements of special nuclear materials. The two agencies agreed to collaborate on the project in response to inconsistencies that were found in the various versions of software and hardware used to determine the isotopic abundances of uranium and plutonium. IRSN used software developed internally to test the MGA and FRAM isotopic analysis codes for criteria used to stop data acquisition. The stop-criterion test revealed several unusual behaviors in both the MGA and FRAM software codes.

2009-01-01

227

Studies on energy level schemes of some nuclei by Gamma-ray spectroscopy  

International Nuclear Information System (INIS)

several authors tried to drive codes to construct nuclear level scheme of nuclei using a set of measured gamma -ray transitions and known energy levels, Ritz combination principle proved to be useful in constructing a more complete decay scheme. In this thesis the energy level schemes of some nuclei have been investigated by the measurements of the gamma - ray energies and use of Ritz combination code. The nuclei under investigation are "110m Ag (253 d)"110 Cd and "166m Ho (1200 yr) "166 E r. On the basis of the suggested level at 2249.02 keV by the Ritz code new positions of the two gamma-ray transitions at 677.5 and 706.6 KeV are found in decay scheme of "110m Ag. Also by this code, new position for the 994.84 KeV gamma-ray transition were established to depopulate the level at 1075.2 KeV.

1984-01-01

228

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The ...

1992-01-01

229

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The ...

1991-10-01

230

Some tests on measuring methods for indoor radon using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Two methods for measuring indoor radon concentrations using activated charcoal have been tested. The first method is the well-known technique with direct gamma-measurements on the exposed canister after the sampling period. The other method uses a thermoluminescence dosemeter placed in the charcoal canister, giving an integrated value of the radon concentration.

1985-10-01

231

Application of alpha-particle spectrometry in post-irradiation research and reprocessing  

Energy Technology Data Exchange (ETDEWEB)

Current applications of ..cap alpha..-particle spectrometry in post-irradiation research and reprocessing are reviewed. Implementation of procedures and techniques described in the literature to the particular samples at S.C.K./C.E.N. often results in a combined radiochemical method where ..cap alpha..-particle spectrometry is used to complement or enforce results obtained by other methods. Typical cases are reported and results obtained by different methods are compared to the results obtained by ..cap alpha..-particle spectrometry.

1984-04-01

232

A detailed analysis of the properties of radiolyzed proteinaceous amino acids  

International Nuclear Information System (INIS)

The thermal behaviour of 21 proteinaceous l-amino acids either as pristine samples and also as radiolyzed (3.2 MGy) samples was studied with the differential scanning calorimeter. The onset and peak melting point as well as the melting enthalpy of all samples before and after the radiation treatment was measured and reported. The residual amount of each amino acid survived to the radiation dose of 3.2 MGy (N_#gamma#) was measured from the melting enthalpies before and after radiolysis and hence the radiation resistance of each amino acid has been determined. The radiolysis causes a systematic reduction of the melting enthalpy and a shift of the onset and peak melting point to lower values. It is shown that N_#gamma# does not correlate with the melting points of the amino acids but shows a correlation with the entity of the shift of the melting point peaks occurred after radiolysis. Such correlation ...

2011-03-01

233

Kinetics of Pd/sub 2/Si layer growth measured by an x-ray diffraction technique  

Science.gov (United States)

An x-ray diffraction approach has been developed for determination of the kinetics of growth of Pd/sub 2/Si layers. Epitaxial Pd/sub 2/Si films were grown on Si(111) substrates over a temperature range of 160-222/sup 0/C by a solid-state reaction between the substrates and the Pd overlayers. The parabolic rate equation was verified and rate constants showed Arrhenius behavior with an activation energy E/sub a/ = 1.06 eV and prefactor k/sub 0/ = 7 x 10/sup -4/ cm/sup 2//s. The low value of E/sub a/ suggests a short-circuit diffusion mechanism. It is reasonable to expect that impurities and microstructure may play important roles in the growth process. Impurity levels in the specimens were evaluated by analytic techniques suited to thin-film study: Rutherford backscattering spectrometry, secondary ion mass spectrometry, and Auger electron spectrometry. No impurities were present at concentrations approaching 1 at. %. Some O, ...

1986-05-15

234

Determination of radon-222 concentration in inside environments of the Instituto de Engenharia Nuclear, Brazil; Determinacao da concentracao de radonio-222 nos ambientes internos das instalacoes do Instituto de Engenharia Nuclear  

Energy Technology Data Exchange (ETDEWEB)

The gotten concentrations of radon-222 in the installations of the IEN had been determined using the active and passive methods. The active method consisted on the use of the alpha spectrometry with a portable equipment Tracerlab Instruments WLM- Plus. In the determination for the passive method, one used detectors of nuclear strokes of type LEXAN. The raised values had been gotten in the wastes deposit and its annexes, room of the press and laboratory of wastes handling. It was observed, in this sector, an instantaneous measure of alpha spectrometry, concentrations around 1000 Bq.m-3, which had over all to the function of storage, the sector, a great volume of natural radioactive materials, especially of radium-226. This determination was carried through in an extreme situation of ventilation zero, where the gates had been kept closed during the execution of the same one. It was observed, however, a considerable fall, with ...

2000-07-01

237

Comparison of the e"+e"-, #gamma#e, #gamma##gamma# linear colliders  

International Nuclear Information System (INIS)

The possibility to transform the future linear e"+e"-colliders into the #gamma#e and #gamma##gamma# colliders with approximately the same energies and luminosities was shown earlier. Their properties are compared from the point of view of possible physical investigations on them. 10 refs.; 1 tab.

1992-06-02

238

$\\gamma/\\phi_3$ at hadron colliders  

CERN Document Server

$\\gamma/\\phi_3$ at hadron colliders

2011-01-01

239

Spatial distributions of {sup 137}Cs and {sup 239+240}Pu in surface seawater within the Exclusive Economic Zone of East Coast Peninsular Malaysia  

Energy Technology Data Exchange (ETDEWEB)

The studies of {sup 137}Cs and {sup 239+240}Pu distributions in surface seawater at South China Sea within the Exclusive Economic Zone (EEZ) of Peninsular Malaysia were carried out in June 2008. The analysis results will serve as additional information to the expanded baseline data for Malaysia's marine environment. Thirty locations from extended study area were identified in the EEZ from which large volumes of surface seawater samples were collected. Different co-precipitation techniques were employed to concentrate cesium and plutonium separately. A known amount of {sup 134}Cs and {sup 242}Pu tracers were used as yield determinant. The precipitate slurry was collected and oven dried at 60 {sup o}C for 1-2 days. Cesium precipitate was fine-ground and counted using gamma-ray spectrometry system at 661.62 keV, while plutonium was separated from other radionuclides using anion exchange, electrodeposited and counted using alpha ...

2010-09-15

240

Luminescence geochronology and evaluation of the environmental dose rate for the Neanderthal deposits at Vindija Cave (Northern Croatia)  

International Nuclear Information System (INIS)

Full text: Optically stimulated luminescence (OSL) dating of individual sand-sized grains of quartz has advanced significantly over the past decade opening up new vistas in luminescence geochronology. Today, single-grain OSL dating can be used to constrain the burial ages of many deposits, including fluvial sediments, glaciofluvial material and archaeological sediments. It also provides a means of examining the stratigraphic integrity of archaeological sites where sediment mixing might have occurred. An OSL age is calculated by dividing the burial dose (the dose absorbed by the grain since it was last exposed to sunlight) by the environmental dose rate (the rate of supply of ionizing radiation to the grain over the period of burial). To obtain reliable OSL ages, therefore, an accurate estimate of the dose rate is required for each sample. Here we describe our OSL dating campaign at Vindija Cave, a key archaeological site in central Europe that contains a 12 m-thick sequence of ...

2008-04-13

241

"1"5"8Tm and "1"5"6Tm decays  

International Nuclear Information System (INIS)

These experiments were performed on the Isocele separator, on-line with the Orsay synchrocyclotron; thulium isotopes were produced by bombarding natural erbium targets with 150nA beam of 157MeV protons. Two Ge(Li) detectors, with resolution of 2.3 and 2.5keV at 1332keV used for #gamma#-ray measurements; conversion electron spectra were measured using a Si(Li) detector. #gamma# spectra, #gamma#-#gamma# coincidence and conversion electron measurements were sufficient to build the flow energy level schemes of the transitional "1"5"8Er and "1"5"6Er nuclei. On both nuclei several quasi rotational bands have been identified. These results are compared with other even erbium isotopes and with the neighboring N=88 and 90 isotones. Comparisons with predictions issued from some classical models are also performed: "1"5"8Er appears as a deformed nucleus very similar to ...

1976-01-01

242

Sequential separation of carrier free {sup 52,56}Mn, {sup 55,56,58}Co and {sup 56,57}Ni from {alpha}-particle activated iron with triisooctylamine  

Energy Technology Data Exchange (ETDEWEB)

A radiochemical charged particle activation procedure for production and separation of carrier free {sup 52,56}Mn, {sup 55,56,58}Co and {sup 56,57}Ni has been developed. The radioisotopes produced on bombardment of an iron foil target with a 40 MeV {alpha}-particle beam through the nuclear reactions, Fe({alpha}, {alpha}pxn){sup 52,56}Mn, Fe({alpha}, pxn){sup 55,56,58}Co and Fe({alpha}, nx){sup 56,57}Ni, have been separated by LLX. The target element and the activation products have been sequentially separated from an HCl medium using diethylether and the liquid anion exchanger, TIOA, as extractants. Extent of separation and purity of the carrier free radiotracers at different stages of their LLX separation have been verified by taking recourse to {gamma}-ray spectrometry. (Author).

1996-04-01

243

Distribution of "2"3"0Th in milling wastes from the Zirovski vrh uranium mine (Slovenia), and its radioecological implications  

International Nuclear Information System (INIS)

Thorium-230, together with "2"3"8U and "2"2"6Ra, was determined (mainly by #gamma#-spectrometry) in samples from the waste piles at Borst and Jazbec in the vicinity of the former uranium mine at Zirovski vrh, Slovenia. Activity (and in the case of uranium, also mass) balances for these nuclides were constructed for the overall operation of the mine and yellow cake plant, using experimental data and known data on ore and uranium production, and nuclide emissions to the environment. All the "2"2"6Ra resulting from ore exploitation is presently contained in the Borst tailings pile. However, because of the very high content of "2"3"0Th in red mud deposited at Jazbec, where 60% of this nuclide is found, the majority of "2"2"6Ra will be found at the Jazbec pile in the future, due to its ingrowth from "2"3"0Th over the next few thousand years. (Author).

244

{sup 48}Ti(n,xnpa{gamma}) reaction cross sections using spallation neutrons for E{sub n} = 1 to 20 MeV  

Energy Technology Data Exchange (ETDEWEB)

{gamma}-ray excitation functions have been measured for the interaction of fast neutrons with {sup 48}Ti (neutron energy from 1 MeV to 250 MeV). The Los Alamos National Laboratory spallation neutron source, at the LANSCE/WNR facility, provided a ''white'' neutron beam which is produced by bombarding a natural W target with a pulsed proton beam. The prompt-reaction {gamma} rays were measured with the large-scale Compton-suppressed Ge spectrometer, GEANIE. Neutron energies were determined by the time-of-flight technique. Excitation functions were converted to partial {gamma}-ray cross sections, taking into account the dead-time correction, the target thickness, the detector efficiency, and neutron flux (monitored with an in-line fission chamber). The data analysis is presented here for neutron energies between 1 to 20 MeV. Partial ...

2005-01-06

245

Geologic and geomorphologic controls of the kaolin deposits of Campo Alegre basin (SC-Brazil); Controles geologicos e geomorfologicos dos depositos de caulim da Bacia de Campo Alegre, SC  

Energy Technology Data Exchange (ETDEWEB)

The most important kaolin deposits from Campo Alegre region (S C) were formed by the conjunction of at least one hydrothermal phase followed by many others weathering, supergenic, phases. Possibly deposits formed by only one of these processes exist, but these deposits shall be small and smaller than those mined today. Besides kaolinization, illitization/muscovitization and silicification, hydrothermalism also generated pyritized and propilitized zones, with quartz + chlorite. Together, hipogenic alterations related to kaolin deposits are very similar to alterations of high sulfidation epigenetic volcanogenic gold deposits. Most part of the biggest kaolin mines from the southern part of Campo Alegre Basin are distributed along a 13 Km long and 0,5 Km width bent zone that is parallel to structural alignments that point out the eastern Basin border. This zone was originated by deformation that has inclined and broken rocks, generating a fault system alongside and parallel to structural ...

2001-03-01

246

Origin of {gamma}-rays from young open clusters  

Energy Technology Data Exchange (ETDEWEB)

The young open cluster Berkeley 87 was predicted to be associated with the COS B {gamma}-ray source 2CG 075+00 on the basis of the experimental evidence of the presence of a shock front around the Wolf - Rayet star ST3 placed in the inner part of the cluster. The CGRO phase-1 data confirm this identification. Protons accelerated at the shock boundary can produce {pi} deg. via p-p interactions and then {gamma}-rays. With the measured flux F{sub {gamma}} (E > 100 MeV) {approx_equal} 9x10{sup -7} ph cm{sup -2} s{sup -1} and the power-law proton spectrum with spectral index {gamma} = 2, the cosmic-ray-energy-density in the inner part ({approx} 0.8 pc radius) of Berk 87 is about 100 times greater than that in the vicinity of the Earth. We have calculated {gamma}-ray spectra expected from the decay of {pi}{sup d}eg. produced in p-p interactions. The spectra ...

1996-08-01

247

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, ...

1988-09-01

248

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in ...

1988-01-01

249

{sup 3}H-tetracycline as a proxy for {sup 41}Ca for measuring dietary perturbations of bone resorption  

Energy Technology Data Exchange (ETDEWEB)

Our group is interested in evaluating early effects of dietary interventions on bone loss. Postmenopausal women lose bone following reduction in estrogen which leads to increased risk of fracture. Traditional means of monitoring bone loss and effectiveness of treatments include changes in bone density, which takes 6 months to years to observe effects, and changes in biochemical markers of bone turnover, which are highly variable and lack specificity. Prelabeling bone with {sup 41}Ca and measuring urinary {sup 41}Ca excretion with accelerator mass spectrometry provides a sensitive, specific, and rapid approach to evaluating effectiveness of treatment. To better understand {sup 41}Ca technology as a tool for measuring effective treatments on reducing bone resorption, we perturbed bone resorption by manipulating dietary calcium in rats. We used {sup 3}H-tetracycline ({sup 3}H-TC) as a proxy for {sup 41}Ca and found that a ...

2007-06-15

250

Application of a gamma spectroscopy system to the measurement of neutron cross sections necessary to the development of nuclear energy; Mise au point d'un systeme de spectroscopie pour mesurer des sections efficaces neutroniques applicables a un possible developpement du nucleaire comme source d'energie  

Energy Technology Data Exchange (ETDEWEB)

This work concerns the development of nuclear energy and nuclear waste management in particular. Two parts of this study can be distinguished. In the first part (theoretical), a thorium-plutonium fuel based on MOX and dedicated for PWR was investigated in order to transmute plutonium in a potentially low waste fuel cycle. It was shown that this type of fuel is not regenerative but could be used for a transition to the industrial thorium fuel cycle without building new reactors. Thanks to moderated neutron spectra and high loaded actinide mass in the core, U-233 is quickly created ({approx}300 kg/y) for a loss of about {approx}1200 kg of fissile plutonium. In the second part (experimental), we have developed and built a new reaction chamber to measure neutron cross sections of actinides by alpha-gamma spectroscopy. This experimental device (in principle transportable) was commissioned in the high flux reactor of ILL Grenoble. Neutron flux was ...

2002-09-01

251

TEM and ToF-SIMS studies on the corrosion behavior of vanadium and chromium containing WC-Co hard metals in alkaline solutions  

British Library Electronic Table of Contents (United Kingdom)

The corrosion behavior of hard metals with VC and Cr3C2 grain growth inhibitors was investigated in alkaline solutions by electrochemical methods. The two inhibitors have opposite effects on the corrosion behavior: Cr3C2 significantly improves the corrosion behavior, whereas VC-containing alloys show a poor resistance. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and analytical transmission electron microscopy (TEM) analyses of the distributions of Cr and V in the composite material, as well as in the surface layers formed during corrosion were employed to clarify the influence of these elements on the corrosion behavior. The measurements showed that VC is precipitated mostly along the WC/binder interface after the liquid-phase sintering process, while Cr3C2 is almost homogene...

2011-01-01

252

Photodegradation of flupentixol in aqueous solution under irradiation at 254nm: Identification of the photoproducts generated  

British Library Electronic Table of Contents (United Kingdom)

After irradiation at 254nm of aqueous solutions of the antipsychotic drug flupentixol, the structures of the photodegradation products were determined by ultra high performance liquid-chromatography linked to mass spectrometry. Fragmentation patterns of the parent ions were established on a hybrid linear ion trap-orbitrap mass spectrometer allowing accurate mass measurements of both parent and daughter ions. This allowed to propose plausible structures for the main photolysis products of flupentixol. A total of nine photoproducts were detected after irradiation of the drug. The main photoproduct is generated following the addition of a hydroxyl group on the double bond adjacent to the thioxanthene ring. Secondary photoproducts were also observed.

2010-01-01

253

Origin determination of plutonium material in nuclear forensics  

International Nuclear Information System (INIS)

Plutonium, seized from illicit trafficking in nuclear materials, can originate from several, distinct sources. The primary focus of nuclear-forensics investigations of confiscated Pu is to specify correctly its origin. Such specification is possible by means of accurate determination the Pu isotopic composition. Five Pu samples of different origins were analysed by thermal-ionisation mass spectrometry. The source (i.e., the type of production reactor) of each sample was determined by comparing the measured Pu isotopic composition with that calculated by one of two reactor-production computer codes, ORIGEN2 and SCALE. These results, in conjunction with the age determination of each sample, allow us to deduce the origin of each. (author)

2000-11-01

254

Myocardial pharmacokinetics of ebastine, a substrate for cytochrome P450 2J, in rat isolated heart  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND AND PURPOSE It is well established that cytochrome P450 2J (CYP2J) enzymes are expressed preferentially in the heart, and that ebastine is a substrate for CYP2J, but it is not known whether ebastine is metabolized in myocardium. Therefore, we investigated its pharmacokinetics in the rat isolated perfused heart. EXPERIMENTAL APPROACH Rat isolated hearts were perfused in the recirculating mode with ebastine for 130-min. The concentrations of ebastine and its metabolites, hydroxyebastine and carebastine, were measured using liquid chromatography with a tandem mass spectrometry. The data were analysed by a compartmental model. The time course of negative inotropic response was linked to ebastine concentration to determine the concentration-effect relationship. KEY RESULTS Ebastine w...

2011-01-01

255

Multielement analysis of air samples. Determination of iron, zinc, lead, and bromine content by the radionuclide X-ray fluorescence analysis  

Energy Technology Data Exchange (ETDEWEB)

Radionuclide X-ray fluorescence analysis for nondestructive determination of Fe, Zn, Pb, and Br in air samples collected on nitrocellulose membrane filter Synpor 4 is described. A /sup 238/Pu source for the excitation and a semiconductor Si/Li detector for the detection of characteristic and L-fluorescent radiation of the above elements were used. A correction method based upon the measurements of simple or multiple Compton scattering for compensation of varying mass per unit area values in sample deposits was theoretically proposed and experimentally tested. The results obtained both with and without the correction were compared and good agreement with those given by atomic absorption spectrometry was observed.

1981-01-01

256

Direct nano ESI time-of-flight mass spectrometric investigations on lanthanide BTP complexes in the extraction-relevant diluent 1-octanol  

Energy Technology Data Exchange (ETDEWEB)

The present work focuses on investigations of a highly selective ligand for Am(III)/Ln(III) separation: bis-triazinyl-pyridine (BTP). By means of nano-electro-spray mass spectrometry, complex formation of BTP with selected elements of the lanthanide series is investigated. We show that the diluent drastically influences complex speciation. Measurements obtained in the extraction-relevant diluent 1-octanol show the occurrence of Ln(BTP){sub i} (i 1-3) species in different relative abundances, depending on the lanthanide used. Here, the relative abundances of the Ln(BTP){sub 3} complexes correlate with the distribution ratios for extraction to the organic phase of the respective lanthanide. (authors)

2009-12-15

257

First Observation of Radiative B^0 -> \\phi K^0 \\gamma Decays and Measurements of Their Time-Dependent CP Violation  

CERN Document Server

We report the first observation of the radiative decay B^0 -> \\phi K^0 \\gamma using a data sample of 772 x 10^6 B B-bar pairs collected at the \\Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric-energy e^+e^- collider. We observe a signal of 37+/-8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is ${\\cal B}(B^0 -> \\phi K^0 \\gamma) = (2.74\\pm 0.60 \\pm 0.32) \\times 10^{-6}$, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP violation parameters: ${\\mathcal S}_{\\phi K_S^0 \\gamma} = +0.74^{+0.72}_{-1.05} (stat)^{+0.10}_{-0.24} (syst)$ and ${\\mathcal A}_{\\phi K_S^0 \\gamma} = +0.35 +/- 0.58 (stat)^{+0.23}_{-0.10} (syst)$. Furthermore, we measure ${\\mathcal ...

2011-01-01

258

Nuclear magnetic moment measurements through hyperfine interactions in highly stripped ions  

International Nuclear Information System (INIS)

Time-differential magnetic moment measurements on the first-excited Isup(#pi#)=2"+ states in "2"0Ne and "2"4Mg with mean lives of 1.0 and 2.1 ps, respectively are described. The lifetime of the latter state was determined simultaneously. A special detection geometry was designed to improve the experimental #gamma#-ray anisotropy measured with finite-size detectors. For "2"0Ne also a time-integral measurement with charge-state separation was performed. The necessary electronics circuitry built to perform these complicated measurements and the plunger assembly with laser interferometer are also described. A magnetic moment measurement of "2"2Ne(2_1"+) with tau=5.0 ps and transient field measurements at low and high recoil velocities are reported. A discussion of possible extensions of the techniques are given. (Auth.).

1975-09-15

259

Serum gamma-glutamyltransferase is associated with arterial stiffness in healthy individuals  

British Library Electronic Table of Contents (United Kingdom)

Summary Objective- Gamma-glutamyltransferase (GGT) has been reported to be useful in predicting cardiovascular disease. Arterial stiffness measured by brachial-ankle pulse wave velocity (baPWV) is not only a marker of vascular damage but a significant predictor of cardiovascular events. Gender difference has been reported in the association between GGT and baPWV. We assessed, therefore, the association between GGT and baPWV in a large population and determined whether there was gender difference. Design- This cross-sectional study was conducted at the Asan Medical Centre, Seoul, Republic of Korea. Subjects and measurements- Serum GGT, baPWV and conventional risk factors were measured in 10 988 apparently healthy subjects (7248 men, 3740 women) who participated in a routine health screening...

2011-01-01

260

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the ...

261

QCD corrections to top quark pair production in association with a photon at hadron colliders  

CERN Document Server

We compute QCD corrections to the production of a ttbar pair in association with a hard photon at the Tevatron and the LHC. This process allows a direct measurement of the top quark electromagnetic couplings that, at the moment, are only loosely constrained. We include top quark decays, treating them in the narrow width approximation, and retain spin correlations of final-state particles. Photon radiation off top quark decay products is included in our calculation and yields a significant contribution to the cross-section. We study next-to-leading order QCD corrections to the ppbar -> ttbar+gamma process at the Tevatron for the selection criteria used in a recent measurement by the CDF collaboration. We also discuss the impact of QCD corrections to the pp -> ttbar+gamma process on the measurement of the top quark electric charge at the 14 TeV LHC.

2011-01-01

262

Neutron capture cross sections for unstable nuclei in the mass 90 region derived from proton capture measurements. [Strength functions  

Science.gov (United States)

Experimental measurements were made of the production cross sections and energy distributions of gamma rays emitted when the stable targets /sup 88/Sr, /sup 89/Y and /sup 90/Zr are exposed to protons in the energy range 3 to 8 MeV. The data are being analyzed using a recent version of the Uhl statistical model code. One conclusion is that while the gamma-ray strength functions employed reproduce the proton capture cross sections, they do not achieve the same degree of hardness observed in the measured spectra. To do so, their lower energy regions must be modified; such changes, however, do not affect the capture cross sections. 7 references.

1978-09-01

263

Production of three vector bosons in {gamma} {gamma} colliders; Producao de tres bosons vetoriais em {gamma} {gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The production of three vector bosons in {gamma} {gamma} collisions studying the reactions {gamma} + {gamma} {yields} W{sup +} + W{sup -} + Z{sup 0} and {gamma} + {gamma} {yields} W{sup +} + W{sup -} + {gamma}. 12 refs., 4 figs., 2 tabs.

1994-12-31

264

Remote temperature inversion sensor  

International Nuclear Information System (INIS)

In conducting aircraft surveys for uranium, it is found that temperature inversions can give spurious results because they promote accumulation of radon gas in the atmosphere. The "2"1"4Bi (daughter product of radon) gamma-rays detected from the atmosphere-borne radon are difficult to separate from the "2"1"4Bi gamma-rays originating from the ground, and providing a signature for uranium deposits. The purpose of the present study was to examine the feasibility of making remote temperature soundings of the atmosphere below a low-flying aircraft (140 m or less above ground) by the inversion of radiance measurements taken in the 15-micron carbon dioxide absorption band. Such measurements would identify those temperature inversion conditions possibly leading to an unacceptably large background of gamma-rays from the atmospheric radon. Thus, the incidence of spurious aerial survey data ...

1977-01-01

265

Coupled neutron - #gamma#-ray diffraction: A method for accurate measurement of strains. Application to the study of the ferroelectric phase transition of KH_2PO_4  

International Nuclear Information System (INIS)

A method that employs simultaneous neutron and #gamma#-ray diffraction techniques is proposed for accurate measurements of strains with or without an applied electric field (0-100 kV m"-"1). Instead of an absolute determination of the position of the neutron Bragg peak, a relative measurement of the neutron and #gamma# peak positions is used and allows a determination of the lattice-parameter changes with an accuracy of within 2 x 10"-"6. This technique avoids systematic errors originating in sample rotations by taking advantage of a reference directly related to the crystal lattice. The method appears to be particularly important for crystals that exhibit structural phase transitions, as demonstrated by the measurement of the strain U_x_x in KH_2PO_4 crystals as a function of temperature and applied electric field. In this case the errors would amount to #+-#20%. The results ...

1987-12-01

266

Corrections for non-homogeneity of the sample in Moessbauer f-factor measurements  

Energy Technology Data Exchange (ETDEWEB)

We describe a procedure for correcting the systematic errors in the Moessbauer f-factor measurement due to non-homogeneous effective thickness of the sample. To be more precise, we show that, if the mass of the sample is determined by means of X- or {gamma}-ray absorption, it is possible to establish experimental conditions so that the error on f due to material non-homogeneity in the sample is minimized.

2002-06-01

267

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically ...

2008-05-22

268

A Simulation Study on a Radioactive Nuclide's Distribution within a Fuel rod by a Tomographic Gamma Scanning  

Energy Technology Data Exchange (ETDEWEB)

Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and ...

2006-07-01

269

Development of food preservation and processing techniques by radiation  

International Nuclear Information System (INIS)

Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as genotoxicity, acute ...

1988-04-18

270

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, ...

1983-01-01

271

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, ...

1983-01-01

272

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting ...

1983-01-01

273

Year-1 (heavy-ion) physics with CMS at the LHC  

International Nuclear Information System (INIS)

The plans for the CERN LHC heavy ion program in 2010 are for collisions of lead ions during the month of November at an energy about half of the final 5.5 TeV/nucleon. The advanced preparations are mostly for extrapolations of the measurements at the maximum energy previously available, Au + Au at 0.2 TeV/nucleon. Because of the large increase in energy, surprises can be expected. One new feature made possible by the increased energy and the excellent muon energy resolution of CMS will be the study of the yields of the excited states of the upsilon meson as a function of angle and centrality. Although the main emphasis will be on the QGP formed by the overlapping parts of the Pb ions, the spectator parts and the electromagnetic field outside of the ions, #gamma#-Pb and #gamma##gamma#, are also important.

2010-06-01

274

Studies of the low-lying levels in /sup 192/Pt and /sup 192/Os  

Energy Technology Data Exchange (ETDEWEB)

The energy level schemes of /sup 192/Os and /sup 192/Pt have been established on the basis of ..gamma..-..gamma.. coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and ..beta../sup -/ decays of /sup 192/Ir to /sup 192/Os and /sup 192/Pt, respectively. Thirteen new transitions and three new levels at 1146.95, 1237.35 and 1913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, ..cap alpha..(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition.

1985-02-01

275

Studies of the low-lying levels in "1"9"2Pt and "1"9"2Os  

International Nuclear Information System (INIS)

The energy level schemes of "1"9"2Os and "1"9"2Pt have been established on the basis of #gamma#-#gamma# coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and #beta#"- decays of "1"9"2Ir to "1"9"2Os and "1"9"2Pt, respectively. Thirteen new transitions and three new levels at 1,146.95, 1,237.35 and 1,913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, #alpha#(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition. (orig.).

1985-01-01

276

Recent results from BESIII  

CERN Document Server

Using about $226\\times 10^6$ $\\jpsi$ events and $106\\times 10^6$ $\\psi^{\\prime}$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider, the Dalitz plot of $\\etap \\to \\eta \\pi^+ \\pi^-$ decay is studied, the direct measurement of $a^{0}_{0}(980)-f_{0}(980)$ mixing is performed, $X(2120)$ and $X(2370)$ are observed in the $\\pi^+\\pi^-\\eta^\\prime$ invariant mass spectrum, $\\psi^{\\prime}\\to\\gamma\\pi^0$ and $\\psi^{\\prime}\\to\\gamma\\eta$ are observed for the first time, and the decays $\\chi_{cJ}\\to\\gamma V$ ($V=\\phi$, $\\rho^0$, $\\omega$) are studied.

2010-01-01

277

PHOTON-HADRON INTERACTIONS AT RHIC AND LHC ENERGIES.  

Energy Technology Data Exchange (ETDEWEB)

Heavy Ion Collisions at RHIC and LHC energies are potentially an interesting laboratory for the study of QED. In these collisions, a Heavy Ion in one beam sees a highly Lorentz contracted electric field due to an oncoming beam particle. The Electric field reaches a maximum value of E {approx_equal} {gamma}{sub eff} {center_dot} Z {center_dot} e/b{sup 2}, where the apparent Lorentz factor, {gamma}{sub eff} = 2 {center_dot} {gamma}{sub beam}{sup 2} - 1. The collision may be viewed in terms of a flux of photons colliding with a stationary ion target using the equivalent photon approximation, originally introduced by Fermi in 1924. We show that the cross section for Inelastic Electromagnetic Interactions of Heavy Ions are both calculable and have been measured in the first RHIC running period.

2002-03-01

278

Interpretation of gamma-scanning data from the ORR demonstration elements  

Energy Technology Data Exchange (ETDEWEB)

The HEU and LEU fuel elements used in the ORR whole-core demonstration were gamma-scanned to determine the axial distribution of the {sup 140}La and {sup 137}Cs activities. Analysis of this data is now complete. From the {sup 140}La activity distributions cycle-averaged powers were determined while the {sup 137}Cs data provided a measure of the final {sup 235}U burnup in the fuel elements. A method for calculating correction factors for activity gradients transverse to the fuel element axis is presented and is applied to the first mixed core used in the demonstration during the gradual transition to an all LEU core. Results based on the gamma-scanning of the LEU fuel followers are also presented. Improved burnup calculations against which the experimental results are to be compared are now in progress. 7 refs., 21 figs., 3 tabs.

1989-01-01

279

Transverse polarization of top quarks produced at a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

At future [gamma][gamma] colliders copious production of [ital t] [bar t] pairs is possible. This would allow for a detailed investigation of the interactions involving the top quark. We propose some correlations which are sensitive to [ital t] [bar t] final state interactions and we compute the QCD and standard model Higgs boson contributions to these correlations. A correlation resulting from the QCD induced transverse polarization of top quarks is found to be sizable and measurable at a high energy [ital e][sup +][ital e][sup [minus

1995-03-01

280

Transverse polarization of top quarks produced at a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

At future {gamma} {gamma} colliders a massive production of tt-bar pairs is possible. This would allow a detailed investigation of the interactions involving the top quark. The authors propose some correlations which are sensitive to tt-bar final state interactions and compute the QCD and standard model Higgs boson contributions to these correlation. QCD-induced transverse polarization of top quarks is found to be sizeable and measurable at a high-energy e{sup +} e{sup -} collider with an integrated luminosity of 10(fb){sup -1} which is converted into a photon collider by backscattering of laser photons. 16 refs.

1995-10-01

281

Transverse polarization of top quarks produced at a photon-photon collider  

International Nuclear Information System (INIS)

At future #gamma##gamma# colliders copious production of t bar t pairs is possible. This would allow for a detailed investigation of the interactions involving the top quark. We propose some correlations which are sensitive to t bar t final state interactions and we compute the QCD and standard model Higgs boson contributions to these correlations. A correlation resulting from the QCD induced transverse polarization of top quarks is found to be sizable and measurable at a high energy e"+e"- collider, which is operated as a photon collider through backscattering of laser photons, at an integrated luminosity of 10 fb"-"1.

282

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

283

Neutron activation analysis of trace elements in Japanese hormesis cosmetics  

International Nuclear Information System (INIS)

In Japan, cosmetics claiming hormesis effect are available through Internet. Although these cosmetics show the contents, they never mention the minor elements and radioactive sources. The existence of radioisotopes, however, was observed by measurements of the gamma-rays with a HPGe detector. In this study, in order to clarify the contents of trace elements, the hormesis cosmetics including radioactive sources were analyzed using INAA, PGAA and NAA with multiple gamma-ray detection (NAAMG). Nineteen elements were analyzed quantitatively in hormesis cosmetics by INAA, PGAA and NAAMG and 16 elements were detected qualitatively by SEM-EPMA. (author)

2008-12-01

284

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

285

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

286

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)

2002-01-01

287

Electron capture decay of sup 203 Pb  

Energy Technology Data Exchange (ETDEWEB)

Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).

1989-01-01

288

ESR spectra of radicals of gamma-irradiated wood and cellulose  

International Nuclear Information System (INIS)

Spectra of e.p.r. radicals in cellulose and timber gamma-irradiated at 77 and 300 K have been measured. Radiation yields and the kinetics of radicals accumulation have been studied. The effect of ionizing radiation on cellulose is the appearance of radicals resulting from rupture of C-H bonds in positions 1 and 4. Timber, additionally, forms ''lignin'' radicals. A mechanism of cellulose and timber radiolysis is suggested. ''Lignin''-type compounds present in timber protect polysaccharides from radiation-induced destruction.

289

$B \\to X_{s} \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ decays at LHCb  

CERN Document Server

\\lhcb is one of the four major experiments at the Large Hadron Collider (\\lhc) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavour hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiments. In this article, the \\lhcb prospects for such measurements with exclusive decays of the type $B \\to \\Xs \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ are presented.

2011-01-01

290

$B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ decays at LHCb  

CERN Document Server

LHC$b$ is one the four major experiments at the Large Hadron Collider (LHC) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavor hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiment. In this article, the LHC$b$ prospects for such measurement with exclusive decays of the type $B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ are presented.

2011-01-01

291

Application of BGO scintillators to absolute measurement of neutron capture cross sections between 0.01 eV and 10 eV  

Energy Technology Data Exchange (ETDEWEB)

Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, ...

1997-07-01

292

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range ...

2001-06-17

293

Neutron cross section measurements using the ORELA: "6"0Ni(n,x), "4"0Ca(n,x), "2"2Ne(n,#gamma#), "1"8"9Os(n,n'), /sup 186,187,188,189/Os(n,x), "1"8"9Os(n,#gamma#), /sup 148,149,150/Sm(n,#gamma#), "1"7"9Ta(n,#gamma#), /sup 86,87,88/Sr(n,x), "4"0Ar(n,x), the stable tellurium isotopes (n,#gamma#) and "2"0"5Tl(n,x). Progress report, September 1, 1984-August 31, 1985  

International Nuclear Information System (INIS)

The research performed during this reporting period (9/1/84 to 8/31/85) resulted in: (1) publication of three papers; (2) presentation of an invited paper to the conference on ''Neutron-Nucleus Collisions: A Probe of Nuclear Structure''; (3) presentation of three contributed papers at APS meetings; and (4) preparation of three manuscripts, two of which are in the process of internal review at the Oak Ridge National Laboratory and are included with this report, and the third is being typed as this report is being written. The publications and papers deal with topics in both nuclear structure and astrophysics. Our efforts to study the systematic behavior of the optical model potential in the energy region just above neutron binding has been made substantially more reliable with the publication of a paper which discusses the accuracy of the methods used to average the measured scattering matrix. In the area of stellar nucleosynthesis, comparison of our model ...

294

Production of intense negative ion beams in magnetically insulated diodes  

Energy Technology Data Exchange (ETDEWEB)

Production of intense negative ion beams in magnetically insulated diodes was studied in order to develop an understanding of this process by measuring the ion-beam parameters as a function of diode and cathode plasma conditions in different magnetically insulated diodes. A coral diode, a racetrack diode, and an annular diode were used. The UCI APEX pulse line, with a nominal output of 1MV, 140kA, was used under matched conditions with a pulse length of 50 nsec. Negative-ion intensity and divergence were measured with Faraday cups and CR-39 track detectors. Cathode plasma was produced by passive dielectric cathodes and later, by an independent plasma gun. Negative-ion currents had an intensity of a few A/cm{sup 2} with a divergence ranging between a few tenths milliradians for an active TiH{sub 2} plasma gun and 300 milliradians for a passive polyethelene cathode. Negative ions were usually emitted from a few hot spots on the cathode surface. ...

1988-01-01

295

Radionuclide contents in food products from domestic and imported sources in Nigeria  

Energy Technology Data Exchange (ETDEWEB)

Samples of some domestic and imported food products of nutritive importance to both the child population and the adult population in Nigeria were collected and analysed in order to determine their radionuclide contents. The samples were collected from open markets in major commercial cities in the country. Gamma-ray spectrometry was employed in the determination of the radionuclide contents in the products. The gamma-ray peaks observed with reliable regularity in all the samples analysed belong to naturally occurring radionuclides, namely {sup 226}Ra, {sup 228}Th and {sup 40}K. The activity concentrations of these radionuclides in both the domestic and imported products were observed to be not significantly different. Essentially radioactive elements such as {sup 137}Cs were not detected in any of the samples. The non-detection of {sup 137}Cs in the imported products may be attributed to the suitably modified agricultural ...

2008-09-01

296

Radionuclide contents in food products from domestic and imported sources in Nigeria  

International Nuclear Information System (INIS)

Samples of some domestic and imported food products of nutritive importance to both the child population and the adult population in Nigeria were collected and analysed in order to determine their radionuclide contents. The samples were collected from open markets in major commercial cities in the country. Gamma-ray spectrometry was employed in the determination of the radionuclide contents in the products. The gamma-ray peaks observed with reliable regularity in all the samples analysed belong to naturally occurring radionuclides, namely "2"2"6Ra, "2"2"8Th and "4"0K. The activity concentrations of these radionuclides in both the domestic and imported products were observed to be not significantly different. Essentially radioactive elements such as "1"3"7Cs were not detected in any of the samples. The non-detection of "1"3"7Cs in the imported products may be attributed to the suitably modified agricultural practices and ...

2008-09-01

297

Penning trap mass spectrometry of neutron-rich Fe and Co isotopes around N=40 with the LEBIT mass spectrometer  

International Nuclear Information System (INIS)

Penning trap mass spectrometry is presented as a complementary tool to nuclear spectroscopy experiments for the study of nuclear structure in the vicinity of N=40, Z=28. High-precision mass measurements of the "6"3"-"6"6Fe and "6"4"-"6"7Co isotopes have been carried out with the Low Energy Beam and Ion Trap (LEBIT) Penning trap mass spectrometer. The newly obtained mass values for "6"6Fe and "6"7Co are presented, together with the previously reported LEBIT mass measurements in this region. In the case of "6"5Fe the existence of a new isomer is reported, and an isomer recently discovered by decay spectroscopy in "6"7Co is confirmed. Relative mass uncertainties as low as 4x10"-"8 are obtained. All mass values are found to be in good agreement with previous experimental results with the exception of "6"4Co, where a 5#sigma# deviation is observed. Using these data the two neutron separation energies S_2_n are calculated. ...

2010-04-01

298

Measurement of 12(S)-hydroxy-5Z,8E,10E-heptadecatrienoic acid and its metabolite 12-oxo-5Z,8E,10E-heptadecatrienoic acid in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry  

International Nuclear Information System (INIS)

Thromboxane A2, the predominant product of arachidonic acid metabolism in the blood platelet, is a potent vasoconstrictor and platelet agonist. During its biosynthesis from cyclic endoperoxide, 12(S)-hydroxy-5Z,8E,10E-heptadecatrienoic acid (HHT) is formed in equal amounts. The further metabolism of HHT, catalyzed by 15-hydroxyprostaglandin dehydrogenase, leads to 12-oxo-5Z,8E,10E-heptadecatrienoic acid (Oxo-HT). Sample workup procedures are described which allow for the sensitive and reproducible determination of these two arachidonic acid metabolites in human plasma by gas chromatography-mass spectrometry in the presence of deuterated analogues as internal standards. HHT is derivatized to the pentafluorobenzyl ester tert-butyldimethylsilyl ether. In order to enable quantification of low concentrations of about 10 pg/ml in nonstimulated human plasma, the samples have to be purified by HPLC. Oxo-HT is derivatized to the pentafluorobenzyl ester, which is purified by ...

1990-01-01

299

Mapping neuropeptide expression by mass spectrometry in single dissected identified neurons from the dorsal ganglion of the nematode Ascaris suum  

UK PubMed Central (United Kingdom)

We have developed a method for dissecting single neurons from the nematode Ascaris suum, in order to determine their peptide content by mass spectrometry (MS). In this paper,...Full Text Available

2010-07-21

300

DNA sequencing using biotinylated dideoxynucleotides and mass spectrometry  

UK PubMed Central (United Kingdom)

Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MS) has been explored widely for DNA sequencing. The major requirement for this method is that the DNA sequencing fragments...Full Text Available

2001-11-01

301

Controlling Gas-Phase Reactions for Efficient Charge Reduction Electrospray Mass Spectrometry of Intact Proteins  

UK PubMed Central (United Kingdom)

Charge reduction electrospray mass spectrometry (CREMS) reduces the charge states of electrospray-generated ions, which concentrates the ions from a protein into fewer peaks spread over a larger...Full Text Available

2005-11-01

302

Excited leptons and quarks at #gamma##gamma#/#gamma#e colliders  

International Nuclear Information System (INIS)

We discuss the search of excited leptons and quarks with spin 1/2 at #gamma##gamma# and at #gamma#e colliders. We show that #gamma##gamma# colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l"*l#gamma# transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).

303

Yields of short-lived fission products produced following "2"3"5U(n_t_h,f)  

International Nuclear Information System (INIS)

Measurements of gamma-ray spectra, following the thermal neutron fission of "2"3"5U have been made using a high purity germanium detector at the University of Massachusetts Lowell (UML) Van de Graaff facility. The gamma spectra were measured at delay times ranging from 0.2 s to nearly 10000 s following the rapid transfer of the fission fragments with a helium-jet system. On the basis of the known gamma transitions, forty isotopes have been identified and studied. By measuring the relative intensities of these transitions, the relative yields of the various precursor nuclides have been calculated. The results are compared with the recommended values listed in the ENDF/B-VI fission product data base (for the lifetimes and the relative yields) and those published in the Nuclear Data Sheets (for the beta branching ratios). This information is particularly useful for ...

1998-08-01

304

Testing gravitational parity violation with coincident gravitational waves and short gamma-ray bursts  

CERN Document Server

Gravitational parity violation is a possibility motivated by particle physics, string theory and loop quantum gravity. One effect of it is amplitude birefringence of gravitational waves, whereby left and right circularly-polarized waves propagate at the same speed but with different amplitude evolution. Here we propose a test of this effect through coincident observations of gravitational waves and short gamma-ray bursts from binary mergers involving neutron stars. Such gravitational waves are highly left or right circularly-polarized due to the geometry of the merger. Using localization information from the gamma-ray burst, ground-based gravitational wave detectors can measure the distance to the source with reasonable accuracy. An electromagnetic determination of the redshift from an afterglow or host galaxy yields an independent measure of this distance. Gravitational parity violation would manifest ...

2010-01-01

305

Performance of the AMS-02 Experiment for High Energy Gamma Ray Astrophysics  

CERN Document Server

AMS is a particle detector designed to perform high precision measurements of the cosmic rays fluxes with the main goals of searching for anti-nuclei, as remnants of primordial anti-matter, and of measuring the faintest components of the cosmic flux, anti- protons, positrons and high energy photons. To fulfill the requirements of large acceptance, long exposure time and excellent particle identification needed to achieve the intended results, AMS will operate in space as an attached payload to the International Space Station (ISS), being the first full featured particle physics experiment to operate in the Earth orbit. The AMS-02 accurate measurements of cosmic-ray nuclei, protons, antiprotons, electrons and positrons will be completed by high energy gamma rays detection. The experiment will detect gamma-rays, either by reconstructing e+e? pairs generated by photons converted ...

2007-01-01

306

Modified Fragmentation Function in Heavy Ion Collisions at RHIC via Direct photon-Jet Measurements  

CERN Document Server

The presented results are the first measurements at RHIC for direct $\\gamma$-charged hadron azimuthal correlations in heavy ion collisions. We use these correlations to study the color charge density of the medium through the medium-induced modification of high-p$_T$ parton fragmentation. Azimuthal correlations of direct photons at high transverse energy (8 $<$ p$_T$ $<$ 16 GeV) with away-side charged hadrons of transverse momentum (3 $<$ p$_T$ $<$ 6 GeV/c) have been measured over a broad range of centrality for $Au+Au$ collisions and $p+p$ collisions at $\\sqrt{s_{NN}}$ = 200 GeV in the STAR experiment. A transverse shower shape analysis in the STAR Barrel Electromagnetic Calorimeter Shower Maximum Detector is used to discriminate between the direct photons and photons from the decays of high p$_T$ $\\pi^{0}$. The per-trigger away-side yield of direct $\\gamma$ is smaller than from ...

2008-01-01

307

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation ...

2005-01-01

308

The Italian survey as the basis of the national radon policy  

Energy Technology Data Exchange (ETDEWEB)

One of the most important goals of the Italian survey, initiated in 1989, was to promote ad hoc policies to reduce radon exposure of the population. In the survey a statistical representative sample of 5000 dwellings was chosen; two six-month measurements were made of the indoor radon concentration, in combination with one six-month measurement of gamma exposure. The results of the radon concentration measurements are reported here: they refer to 80% of the sample. The annual mean value was 81.5Bq.m{sup -3}, which is higher than that reported for other industrialised countries. (author).

1994-12-31

309

Radon measurements in dwellings using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.

1984-01-01

310

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

311

Measurement of the inclusive Z production cross section with the CMS detector  

CERN Document Server

First measurements of inclusive Z production cross sections in muon and electron decay channels at 7 TeV are presented for proton-proton collisions in the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). The comparison of the kinematic quantities as well as the studies of selection efficiencies demonstrate a good agreement between simulated events and current data. The measured inclusive cross section for Z($\\gamma^{*}$) production agrees with NNLO QCD cross section calculations and current parton distribution functions.

2010-01-01

312

Half-lives of the T{sub z}=1/2 series nuclei, {sup 81}Zr and {sup 85}Mo  

Energy Technology Data Exchange (ETDEWEB)

The nuclei {sup 81}Zr and {sup 85}Mo with T{sub z}=1/2 have been reinvestigated via their {beta}-delayed proton emissions with p-{gamma} coincidence measurement. The half-life of {sup 81}Zr has been measured to be 5.3{+-}0.5 s, which agrees with one of the two previous values. For {sup 85}Mo, the measured half-life is 3.2{+-}0.2 s, which revises the previous value. (orig.) With 3 figs., 12 refs.

1997-12-01

313

Half-lives of the T_z=1/2 series nuclei, "8"1Zr and "8"5Mo  

International Nuclear Information System (INIS)

The nuclei "8"1Zr and "8"5Mo with T_z=1/2 have been reinvestigated via their #beta#-delayed proton emissions with p-#gamma# coincidence measurement. The half-life of "8"1Zr has been measured to be 5.3#+-#0.5 s, which agrees with one of the two previous values. For "8"5Mo, the measured half-life is 3.2#+-#0.2 s, which revises the previous value. (orig.).

314

FFTF shield and gamma ray measurements  

Energy Technology Data Exchange (ETDEWEB)

Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.

1984-08-01

315

Decay of "1"0"1Mo and "1"0"1Tc  

International Nuclear Information System (INIS)

... beta decay coincidence spectrometry energy levels energy-level transitions

316

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming ...

2007-07-01

317

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that ...

2003-10-01

318

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

International Nuclear Information System (INIS)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection ...

2003-10-01

319

Quality control and evaluation for environmental radiological baseline study of Guangdong Daya Bay nuclear power station  

International Nuclear Information System (INIS)

The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.

320

Minimal Neutrino Beta Beam for Large theta_13  

CERN Document Server

We discuss the minimum requirements for a neutrino beta beam if theta_13 is discovered by an upcoming reactor experiment, such as Double Chooz or Daya Bay. We require that both neutrino mass hierarchy and leptonic CP violation can be measured to competitive precisions with a single-baseline experiment in the entire remaining theta_13 range. We find that for very high isotope production rates, such as they might be possible using a production ring, a (B,Li) beta beam with a gamma as low as 60 could already be sufficient to perform all of these measurements. If only the often used nominal source luminosities can be achieved, for example, a (Ne,He) beta beam from Fermilab to a possibly existing water Cherenkov detector at Homestake with gamma \\sim 190-350 (depending on the Double Chooz best-fit) could outperform practically any other beam technology including wide-band beam and neutrino factory.

2008-01-01

321

Measurement of induced radioactivity in materials found around a neutron generator  

Science.gov (United States)

The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)

1974-01-01

322

La{sup 3+} modified Al{sub 2}O{sub 3} as a support for CeO{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoelectron spectroscopy measurements indicate that the Ce{sup 3+} like fraction in {gamma}-Al{sub 2}O{sub 3} supported CeO{sub 2} can be decreased by the incorporation of La{sup 3+}. If La{sup 3+} is incorporated into the {gamma}-Al{sub 2}O{sub 3} before CeO{sub 2} is added, a higher CeO{sub 2} dispersion and a greater range of reversible reducibility of the CeO{sub 2} may also be obtained. These changes offer potential for improvement in the oxygen storage capacity provided by CeO{sub 2} in three-way catalysts. The actual effect of La{sup 3+} incorporation on the activity and durability of a Pt catalyst is assessed by a combination of temperature programmed reduction and flow reactor measurements.

1993-12-31

323

FFTF reactor characterization program  

International Nuclear Information System (INIS)

Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the reactor vessel and the concrete wall.

324

Environmental trace gas analysis by proton-transfer-reaction mass spectrometry (PTR-MS)  

International Nuclear Information System (INIS)

The work presented here demonstrates the ability of proton-transfer-reaction mass spectrometry (PTR-MS) to perform fast-response measurements of volatile organic compounds (VOCs) (including methanol, acetonitrile, acetaldehyde, acetone, PAN-type compounds, alpha- and beta-pinene, nopinone and pinonaldehyde) at the pptv level and its versatile applicability in the field of environmental trace gas analysis. Laboratory and field experiments including various calibration techniques and intercomparisons with other measurement techniques such as gas chromatography, atmospheric pressure chemical ionization and Fourier transformation infrared spectroscopy were performed providing a first characterization of the PTR-MS instrument performance (sensitivity, detection limit, precision, accuracy). Typically a detection limit (S/N=2) of 50 pptv for a 10 s signal integration time, a precision of 5 % and an accuracy in the range between 10 ...

325

Signatures of extra dimensions at e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The authors study the processes {gamma}e {r{underscore}arrow} {gamma}e and {gamma}{gamma} {r{underscore}arrow} {gamma}{gamma}, in the context of the proposal for Weak Scale Quantum Gravity (WSQG) with large extra dimensions. With an ultraviolet cutoff M{sub S} {approximately} 1 TeV for the effective gravity theory, the cross sections obtained for these processes at the Next Linear Collider (NLC), with the e{gamma} an {gamma}{gamma} options, deviate from the predictions of the Standard Model significantly. The results suggest that, for typical proposed NLC energies and luminosities, the predictions of WSQG can be tested in the range 1 TeV {approx{underscore}lt} M{sub S} {approx{underscore}lt} 10 TeV, making e{gamma} an {gamma}{gamma} colliders important tools for probing WSQG.

2000-01-26

326

Transmutation of technetium in the Petten HFR. A comparison of measurements and calculations  

Energy Technology Data Exchange (ETDEWEB)

Within the framework of the EFTTRA cooperation between CEA, ECN, EDF, FZK, IAM and ITU, six metallic {sup 99}Tc rods have been irradiated in the Petten HFR for 193 effective full power days. During this irradiation, more than 6% of the {sup 99}Tc has been transmuted to the stable {sup 100}Ru. At ECN, one of the six rods has been examined in the hot cell laboratory. The ruthenium concentration in the rod measured by Isotope Dilution Mass Spectrometry reaches 6.4% at 5 mm from the bottom of the rod and 6.0% at 5 mm from the top. Also the axial and radial distributions of the ruthenium have been measured by Electron Probe Micro Analysis. The ruthenium concentrations calculated by the three-dimensional Monte Carlo code KENO reach 6.1% at 5 mm from the bottom of the rod and 5.7% at 5 mm from the top. These values are in reasonable agreement with the measured ones. However, the calculated radial distribution ...

1996-10-01

327

The Galactic Center Region Gamma Ray Excess from A Supersymmetric Leptophilic Higgs Model  

CERN Document Server

In a recent paper by Hooper and Goodenough, data from the Fermi Gamma Ray Telescope was analyzed and an excess of gamma rays was found in the emission spectrum from the Galactic Center Region. Hooper and Goodenough show that the excess can be well explained by 7-10 GeV annihilating dark matter with a power law density profile if the dark matter annihilates predominantly to tau pairs. In this paper we present such a dark matter model by extending the MSSM to include four Higgs doublets and one scalar singlet. A Z2 symmetry is imposed that enforces a Yukawa structure so that the up quarks, down quarks, and leptons each receive mass from a distinct doublet. This leads to an enhanced coupling of scalars to leptons and allows the model to naturally achieve the required phenomenology in order to explain the gamma ray excess. Our model yields the correct dark matter thermal relic density and avoids collider bounds from ...

2011-01-01

328

T=(5/2) "2"7Na from "1"4C+"1"4C, and the N=16 shell gap  

International Nuclear Information System (INIS)

For the first time a comprehensive level and decay scheme has been obtained for a T=(5/2) nucleus in the s-d shell ("2"7Na) by using a radioactive beam and target. Particle-#gamma# and p-#gamma#-#gamma# coincidences were measured following the "1"4C("1"4C,p#gamma#)"2"7Na reaction at E_l_a_b=22 MeV. The results do not support an inversion of the 2s_1_/_2 and 1d_5_/_2 orbitals, as previously proposed for T_z#>=#3, but they do suggest an increased N=16 gap between the 2s_1_/_2 and 1d_3_/_2 orbitals due to the neutron excess. A consistent interpretation of the level scheme in terms of the s-d shell model using the USD Hamiltonian is possible below 4 MeV, but differences increase at higher excitation energies. Another interpretation is that the influences of both the p_1_/_2 and f_7_/_2 intruder orbitals increase simultaneously with increasing T, an effect not included in the USD Hamiltonian.

2002-05-01

329

Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions  

International Nuclear Information System (INIS)

The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical ...

330

Radiological assessment of terrestrial environment of facilities of G.I.P. CYCERON from Caen - year 2003; Bilan radiologique de l'environnement terrestre des installations du GIP CYCERON de Caen - annee 2003  

Energy Technology Data Exchange (ETDEWEB)

Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma ...

2004-07-01

331

Radiation damage and recovery in the light emittance efficiency and the attenuation length of barium fluoride scintillator  

International Nuclear Information System (INIS)

Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight ...

332

Diffuse $\\gamma$-rays and $\\bar{p}$ flux from dark matter annihilation -- a model for consistent results with EGRET and cosmic ray data  

CERN Document Server

In this work we develop a new propagation model for the Galactic cosmic rays based on the GALPROP code, including contributions from dark matter annihilation. The model predicts compatible Galactic diffuse $\\gamma$ ray spectra with EGRET data in all sky regions. It also gives consistent results of the diffuse $\\gamma$ ray longitude and latitude distributions. Further the results for B/C, $^{10}$Be/$^9$Be, proton, electron and antiproton spectra are also consistent with cosmic ray measurements. In the model we have taken a universal proton spectrum throughout the Galaxy without introducing large fluctuation for the proton energy loss is negligible. The dark matter annihilation signals are `boosted' after taking the contribution from subhalos into account. Another interesting feature of the model is that it gives better description of the diffuse $\\gamma$ rays when taking the source distribution ...

2007-01-01

333

Time-resolved reflectance studies of silicon during laser thermal processing of amorphous silicon gates on ultrathin gate oxides  

International Nuclear Information System (INIS)

In this paper, we report the systematic investigation on the melt characteristics of silicon during laser thermal processing (LTP) of amorphous silicon (a-Si) gates on ultrathin gate oxides. LTP is used to reduce the gate depletion effect in advanced semiconductor devices. The influence of implantation-induced damage and chemical inhomogeneities on the melt behavior of ion-implanted a-Si is studied using in situ time-resolved reflectance (TRR) measurements and ex situ secondary ion mass spectrometry. The results from TRR measurements indicate the presence of a buried melt for a-Si implanted with B"+ at a subamorphizing dose. In contrast, such a melt behavior is not observed during LTP of undoped a-Si and a-Si implanted with As"+ at an amorphizing dose. We attribute the marked difference in the melt characteristics to the competitive effects between compositional inhomogeneities and the extent of amorphization in the a-Si ...

2004-06-01

334

SIMS and XRD measurements for the critical review of carbon diffusivity derivation from hardness profiles  

Energy Technology Data Exchange (ETDEWEB)

Microhardness decarburization profiles are often used in the industry to estimate the carbon distribution in steels. For quantitative evaluation, an analysis based on diffusion theory must be performed, the fundamentals and mathematical basics of which are presented. If the relationship between hardness and carbon content is known, microhardness-distance curves of steels can be analyzed in this way. For martensitic grades, for instance, a linearized expression holds in the concentration range from 0.15 to 0.6 m.% C. Microhardness depth profiles of higher carbon steels and other microstructures, however, are also evaluated in the literature. The applicability of quantitative diffusion modeling is discussed in detail. Through hardenable rolling bearing steel 100Cr6 (1.3505, SAE 52100) serves as model material: carbon concentration-distance curves are measured with high accuracy by secondary ion mass spectrometry (SIMS) and compared with ...

2007-07-01

335

Role of accelerator mass spectrometry in biological dosimetry  

International Nuclear Information System (INIS)

Understanding risks from exposures to carcinogens and other chemicals depends upon measurement of their dose to target tissues and their reactivity with critical macromolecules. The authors have used AMS detection of radio-isotopes to assess doses and reactivities at low, environmentally relevant doses. Several biomedical investigations show the effectiveness of quantification of biologically important events at extremely high sensitivity with AMS. Specifically, they have measured the addition of environmental carcinogens such as 2-amino-3,8-dimethylimidazo[4,5-f]-quinoaxaline (MelQx), a chemical found in cooked food, to DNA at concentrations relevant to human exposure. Other low level detection problems in biology, such as immunoassay assessment of small environmental chemicals, is being developed with attomole sensitivity. AMS also aids the assessment of genotoxic risks from chemicals by quantifying the binding of labeled chemicals to DNA. ...

1992-04-05

336

Phosphate/UO{sub 2} interaction during in vitro dissolution of inhalable particles in a medium simulating the phagolysosomal compartment  

Energy Technology Data Exchange (ETDEWEB)

Qualitative and quantitative methods have been developed to relate phosphate/UO{sub 2} interactions and U dissolution, in vitro, in a medium containing 0 or 10 mM phosphate concentrations at pH 5. This was performed by Energy Dispersive X ray Spectrometry (EDS) at 200 kV on entire particles and by fluorimetric measurement. The U dissolution rate was larger in a medium without phosphate than in a medium containing 10 mM phosphate. During the first day, the initial U dissolution involved 80.55% and 91.13% of the powder in media with and without phosphate respectively. From 5 to 15 d after beginning the assay, the dissolution half-times were longer than 92 d and 22 d for media with and without phosphate. EDS analyses have shown a constant P/U X ray intensity ratio for reference U{sub 2}O(PO{sub 4}){sub 2} for the same range of particle diameter. A gradual increase of this ratio was measured for UO{sub 2} incubated in a 10 mM ...

1998-07-01

337

Influence of antioxidants on service life of high speed ball bearings lubrication; Einfluss von Antioxidantien auf die Schmierfettgebrauchsdauer in schnelllaufenden Waelzlagern  

Energy Technology Data Exchange (ETDEWEB)

Under severe operating conditions, such as starved lubrication, performance, service life, and reliability of rolling element bearings depend on the chemical and physical interactions between the contacting surfaces, the lubricant components, and the atmosphere. The IMKT{sup 1}, PI{sup 2}, and the imt{sup 3} have been cooperating on systematic investigations of interfacial interactions in high speed grease lubricated ball bearings. These include long time tests with complete bearings lubricated with greases of different composition under defined operating conditions, conducted at the IMKT, and chemical and physical characterizations of the running surfaces at the PI and imt. At the PI, in particular the chemical nature of the boundary layers has been investigated with time of flight secondary ion mass spectrometry (TOF-SIMS). The imt has been involved in the investigations by measuring the physical/mechanical properties of interacting surfaces ...

2004-07-01

338

Deposition of Cu film on SiO_2 using a partially ionized beam  

International Nuclear Information System (INIS)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO_2 substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio I(111)/I(200) reaches its maximum value indicating a strong left-angle 111 right-angle texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, compositional and ...

1990-01-01

339

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Energy Technology Data Exchange (ETDEWEB)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, ...

1990-05-01

340

Deposition of Cu film on SiO sub 2 using a partially ionized beam  

Science.gov (United States)

Ion bombardment during deposition can significantly modify the film properties. In the partially ionized beam deposition, ions derived from the depositing material, i.e., the self-ions, are used during deposition. Cu films were deposited on SiO{sub 2} substrates at room temperature using 1% Cu self-ions with an energy ranging between 0--4 keV. We studied the microstructures of the Cu films using x-ray diffraction and transmission electron microscopy, measured the impurity level inside the films using secondary ion mass spectrometry, and performed the resistivity measurements using a four point probe. The results indicate that there is an optimum ion energy around 2 keV at which, the integrated x-ray intensity ratio {ital I}(111)/{ital I}(200) reaches its maximum value indicating a strong {l angle}111{r angle} texture, while the impurity concentration and resisitivity are minimum. The correlation between the structural, ...

1990-05-01

341

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. ...

342

The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not been reported previously, whereas in the case of SEI glass, there exists a modest body of previous work on ...

1990-01-01

343

The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters  

International Nuclear Information System (INIS)

The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not been reported previously, whereas in the case of SEI glass, there exists a modest body of previous work on ...

344

Particle emission from low energy nuclear reactions in solids. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons or deuterons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Deuteron irradiation of TiD{sub 2} produced these observations: copious {approx}2.5 MeV neutrons and {approx}3 MeV protons from direct D-D reactions; gamma rays from p,{gamma} and n,{gamma} reactions; {approx}14 MeV protons from the secondary d({sup 3}He, p){alpha} reaction; and a signal between {approx}6-12 MeV that Kasagi et al. has tentatively identified as protons from the fusion of three deuterium nuclei. However, this signal has in it a strong interference signal from either neutrons or gamma rays that directly deposit energy in the detector. This interference spectra was measured by placing a thick absorber in front of the detector that stops up to 20 MeV protons, but not ...

2000-07-01

345

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons  

Energy Technology Data Exchange (ETDEWEB)

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical ...

2010-05-01

346

Quick separation of fission product molybdenum and gamma-rays of Mo-102  

International Nuclear Information System (INIS)

... electrophoresis fission products gamma radiation gamma spectra half-life

347

Probing of the Higgs-fermion coupling at. gamma. gamma. -colliders  

Energy Technology Data Exchange (ETDEWEB)

Three possibilities to observe the Higgs-top interaction at future {gamma}{gamma}-colliders are discussed: (a) associated Higss production via the {gamma}{gamma}{yields}tanti tH reaction, (b) Higgs obliged radiative correction to the {gamma}{gamma}{yields}tanti t channel, (c) Higgs resonance production via {gamma}{gamma}{yields}H{yields}ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at {gamma}{gamma}-colliders. (orig.).

1992-11-01

348

Probing of the Higgs-fermion coupling at #gamma##gamma#-colliders  

International Nuclear Information System (INIS)

Three possibilities to observe the Higgs-top interaction at future #gamma##gamma#-colliders are discussed: a) associated Higss production via the #gamma##gamma##->#tanti tH reaction, b) Higgs obliged radiative correction to the #gamma##gamma##->#tanti t channel, c) Higgs resonance production via #gamma##gamma##->#H#->#ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at #gamma##gamma#-colliders. (orig.).

349

Proceedings of the first meeting on e{gamma}/{gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The first meeting on e{gamma}/{gamma}{gamma} colliders was held on September 28 and 29, 1993, at the National Laboratory for High Energy Physics. After general remarks were delivered, lectures were given on QED in intense laser field, photon linear collider, laser focusing, luminosity distribution in the e{gamma}/{gamma}{gamma} colliders, QCD correction for {gamma}{gamma}{yields}H, radiation correction for e{gamma}/{nu}W process, SUSY particle production at the e{gamma} and {gamma} gamma colliders, formation of e{sup *} in e{gamma} collision, and general remarks on the theory. Discussion was carried out on `Where are we going from here?` In this book, the gists of the lectures are collected. (K.I.).

1994-01-01

350

Screening for congenital hypothyroidism in Lebanon - An example of newborn screening in absence of mandatory law  

International Nuclear Information System (INIS)

This paper presents a group's efforts to introduce national newborn screening in Lebanon. Tandem mass spectrometry (MS) technology offers the prospect of utilizing filter paper blood specimens to screen newborns for several metabolic disorders. In order to be cost-effective, it is necessary to have a mandatory newborn screening policy. At present such a policy is not available in Lebanon. A national screening survey for congenital hypothyroidism (CH) was carried out to assess the incidence of this anomaly in the Lebanese population. Such an initiative is essential as a first step for assessing the feasibility and cost of a national screening programme. Coated beads, blood spot standards for quality control and buffer solutions used for assays were prepared in-house to minimize costs. At first, samples of umbilical cord blood spots were assayed for TSH using IRMA technique. Those samples showing borderline or high values of TSH were then assayed for total T4 (TT4) ...

2004-10-01

351

Mass spectrometric characterization of elements and molecules in cell cultures and tissues  

Energy Technology Data Exchange (ETDEWEB)

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) and laser post-ionization secondary neutral mass spectrometry (laser-SNMS) have been used to image and quantify targeted compounds, intrinsic elements and molecules with subcellular resolution in single cells of both cell cultures and tissues. Special preparation procedures for analyzing cell cultures and tissue materials were developed. Cancer cells type MeWo, incubated with boronated compounds, were sandwiched between two substrates, cryofixed, freeze-fractured and freeze-dried. Also, after injection with boronated compounds, different types of mouse tissues were extracted, prepared on a special specimen carrier and plunged with high velocity into LN{sub 2}-cooled propane for cryofixation. After trimming, these tissue blocks were freeze-dried. The measurements of the K/Na ratio demonstrated that for both cell cultures and tissue materials the special preparation ...

2006-07-30

352

Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array  

Science.gov (United States)

The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a ...

2009-03-10

353

An aerial radiological survey of the Portsmouth Gaseous Diffusion Plant and surrounding area  

International Nuclear Information System (INIS)

An aerial radiological survey was conducted from August 10-16, 1993, over a 78-square-kilometer (30-square-mile) area of the Portsmouth Gaseous Diffusion Plant and surrounding area located near Portsmouth, Ohio. The survey was performed at a nominal altitude of 46 meters (150 feet) with a line spacing of 76 meters (250 feet). A contour map of the terrestrial gamma exposure rate extrapolated to 1 meter above ground level was prepared and overlaid on a set of United States Geological Survey topographic maps of the area and an aerial photograph of the plant. The terrestrial gamma exposure rates varied from about 7 to 14 microroentgens per hour at 1 meter above the ground. Protactinium-234m was observed at six sites within the boundaries of the plant. At a seventh site, only uranium-235 was observed. No other man-made, gamma ray-emitting radioactive material was present in a detectable quantity, either on or off the plant ...

2005-05-01

354

Uranium isotopic assay instrument  

International Nuclear Information System (INIS)

Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic fluorescence and ...

2006-10-16

355

The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core  

Energy Technology Data Exchange (ETDEWEB)

This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in ...

2006-07-15

356

Development of a Computer Program for the Integrated Control of the Fuel Homogeneity Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The computer program is developed based on Visual C++, which is equipped with a user-friendly interface of the input/output(I/O) and a display function for the measuring conditions. This program consists of three parts which are the port communication, PLC(Programmable Logic Controller) and the MCA(Multi Channel Analyzer) control parts. The communication type between the CPU of the PLC module box and the computer is selected as be the Rs-232 asynchronous type and the thread method is adapted in the development of the first part of the program. The PLC-related program has been developed so that the data communication between the PLC CPU and the computer could be harmonized with the unique commands which have already been defined in the PLC. The measuring space and time intervals, the start and end ROI(region of interest) values, and the allowable error limitation are input at each measurement in this program. Finally the ...

2005-11-15

357

Width of the 1. 836-MeV level in /sup 88/Sr  

Science.gov (United States)

Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2/sup +//sub 1/ level in /sup 88/Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.

1977-06-01

358

The triaxial motion in Mo isotopes  

Energy Technology Data Exchange (ETDEWEB)

The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of [sup 87]Mo are studied in detail and explained by the evolution of the [gamma]-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N [>=] 47 for the spherical shape of the Mo isotopes. (orig.)

1993-11-22

359

The triaxial motion in Mo isotopes  

International Nuclear Information System (INIS)

The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of "8"7Mo are studied in detail and explained by the evolution of the #gamma#-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N #>=# 47 for the spherical shape of the Mo isotopes. (orig.).

360

Tests for mutagencity of free radicals formed in irradiated sugars and amino acids  

International Nuclear Information System (INIS)

Radicals formed in gamma-irradiated crystals of galactose and glycine were found, upon dissolution, to cause mutagenesis of Salmonella typhimurium strains TA-98 and TA-100. Although the reproducibility of the results has not been adequately determined, they suggest the possibility of developing a test to measure the mutagenic-carcinogenic potential of radiation-induced free radicals with a microbial system.

1977-05-01

361

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

362

Radiation treatment of some poultry products  

International Nuclear Information System (INIS)

Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.

1988-09-26

363

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

364

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

365

Investigation of Moessbauer radiation diffraction on Fe/sub 3/BO/sub 6/ monocrystal. Nuclear transition interference  

Energy Technology Data Exchange (ETDEWEB)

Energy spectra of the Bragg reflection of the Moessbauer ..gamma..-radiation from the /sup 57/Fe/sub 3/BO/sub 6/ weakly ferromagnetic monocrystal are studied. A strong effect of the interference transitions in iron nuclei, being in non-equivalent positions, on the spectra form is revealed. The measurement results are compared with theoretical calculations.

1984-05-25

366

In-beam conversion electron spectroscopy using the SACRED array  

International Nuclear Information System (INIS)

Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.

367

Evaluation of radiation resistance of cable connector material  

Energy Technology Data Exchange (ETDEWEB)

Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.

2002-10-01

368

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

369

Anomalous solvent extraction behavior of astatine  

International Nuclear Information System (INIS)

We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).

370

Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors  

Energy Technology Data Exchange (ETDEWEB)

A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.)

1993-10-01

371

Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors  

International Nuclear Information System (INIS)

A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.).

372

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

Energy Technology Data Exchange (ETDEWEB)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. ...

2007-11-15

373

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

International Nuclear Information System (INIS)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate ...

2007-11-01

374

Modification of SGS system for application to various sized drums  

Energy Technology Data Exchange (ETDEWEB)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is ...

2005-11-15

375

Modification of SGS system for application to various sized drums  

International Nuclear Information System (INIS)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is ...

2005-11-01

376

Assay of the uranium and plutonium content in process residues and wastes using the correction for sample self attenuation in segmented gamma scanning system  

International Nuclear Information System (INIS)

A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurement results is also studied. The measurement results of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The uncertainty of measurement results for uranium and plutonium ...

1998-09-01

377

Application od scaling technique for estimation of radionuclide inventory in radioactive waste  

International Nuclear Information System (INIS)

Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and TRUs. The measurements ...

1996-09-16

378

The ''nuclear car wash'': a scanner to detect illicit special nuclear material in cargo containers  

International Nuclear Information System (INIS)

There is an urgent need to improve the reliability of screening cargo containers for illicit nuclear material that may be hidden there for terrorist purposes. A screening system is described for detection of fissionable material hidden in maritime cargo containers. The system makes use of a low intensity neutron beam for producing fission; and the detection of the abundant high-energy #gamma# rays emitted in the #beta#-decay of short-lived fission products and #beta#-delayed neutrons. The abundance of the delayed #gamma# rays is almost an order of magnitude larger than that of the delayed neutrons normally used to detect fission and they are emitted on about the same time scale as the delayed neutrons, i.e., #approx#1 min. The energy and temporal distributions of the delayed #gamma# rays provide a unique signature of fission. Because of their high energy, these delayed #gamma# rays penetrate loW--Z ...

2004-01-28

379

GaP Project: #gamma#p, #gamma#e, #gamma##gamma# colliders physical programs and CompHEP computer system  

International Nuclear Information System (INIS)

The Gamma Physics (GaP) program of physical phenomena investigation is proposed on #gamma#p, #gamma#e and #gamma##gamma# colliders at TeV energies. The program contains specialized software (CompHEP system) created for automation of particle interaction processes calculations in the framework of various gauge models. Preliminary physical results are presented (heavy quark production, W, Z production, supersymmetry etc.), and further software development is suggested. (R.P.) 22 refs., 8 figs., 4 tabs.

380

Solution of the orthopositronium lifetime puzzle  

CERN Document Server

The intrinsic decay rate of orthopositronium formed in SiO/sub 2/ powder is measured using the direct 2 gamma correction method such that the time dependence of the pick-off annihilation rate is precisely determined. The decay rate of orthopositronium is found to be 7.0396+or-0.0012(stat.)+or-0.0011(sys.)/ mu s/sup -1/, which is consistent with our previous measurements with about twice the accuracy. Results agree well with the O( alpha /sup 2/) QED prediction, and also with a result reported very recently using nanoporous film.

2004-01-01

381

Moessbauer diffraction measurements on polycrystalline bcc iron  

Energy Technology Data Exchange (ETDEWEB)

In the early days of Moessbauer spectroscopy, it was demonstrated that coherent scattering of photons emitted by a Moessbauer source can be observed. In spite of the fact that scattering experiments could give information not accessible by the absorption method, they are not widely used. The reasons for this are, on the one hand, experimental difficulties, and on the other hand, the form of the samples, which should be large single crystals in most cases. In this work, we present a Moessbauer diffraction measurement on polycrystalline bcc iron where these problems have been overcome. We demonstrate that using the kinematical theory of gamma-ray diffraction, useful information on the relative orientation of the crystallographic axis to the hyperfine field directions can be subtracted. (orig.)

1994-11-01

382

MCNP-DSP calculations of the {sup 252}Cf-source-driven noise analysis measurements of highly enriched uranium metal cylinders  

Energy Technology Data Exchange (ETDEWEB)

This paper presents calculations of the {sup 252}Cf-source-driven noise analysis measurements for subcritical highly enriched uranium metal cylinders using the Monte Carlo code MCNP-DSP. This code directly calculates the noise analysis data from the {sup 252}Cf- source-driven noise analysis method for both neutron and gamma ray detectors. Direct calculation of experimental observables by the Monte Carlo method allows for the benchmarking of the calculational model and the cross sections and for determining the bias in the calculation.

1995-07-01

383

Effect of substrate on the results of measuring coating thickness according to radiation scattered by substrate  

International Nuclear Information System (INIS)

The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.

384

The neutron capture cross sections of {sup 237}Np(n,{gamma}) and {sup 240}Pu(n,{gamma}) and its relevance in the transmutation of nuclear waste  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture cross sections of actinides are of great relevance for the Transmutation of Nuclear Waste in Accelerator Driven Systems (ADS) and Generation-IV reactors. The neutron capture cross sections of {sup 237}Np and {sup 240}Pu in the range of 1 eV to 2 keV were measured at the n-TOF facility with a Total Absorption Calorimeter. The data have been analyzed with the SAMMY code. The corresponding covariance matrices have been generated. The final cross sections are presented and compared to the previously existing ones.The n-TOF {sup 237}Np {sigma}(n,{gamma}) is in agreement with the evaluated data files below 300 eV and its is lower by 10 to 15% up to 2 keV. This discrepancy with the evaluated data files is also observed in the capture cross section derived from the transmission measurements of Gressier et al. In the case of the {sup 240}Pu {sigma}(n,{gamma}), the n-TOF ...

2008-07-01

385

A spatial sensitivity analysis technique for neutron and gamma-ray measurements  

International Nuclear Information System (INIS)

In the fields of medical imaging, geophysical well logging, and industrial radiography, it is often of interest to characterize the spatially distributed sensitivities of neutron and gamma-ray measurement devices to the physical properties of the materials being examined. For instance, one may wish to know how the count rate in a detector varies in response to small changes in the local density of the irradiated object as a function of position. Experimental determination of such sensitivity functions is often impractical. Consequently, we have developed a general three-dimensional Monte Carlo numerical technique that allows us to directly compute the differential sensitivity of an arbitrary integral response parameter, such as a time- or energy-discriminated count rate, with respect to the spatial distribution of macroscopic cross sections and sources in the irradiated medium. Sensitivities to object density, porosity, etc., can easily be ...

1992-09-08

386

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

Energy Technology Data Exchange (ETDEWEB)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of {sup 226}Ra and {sup 232}Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

1999-07-01

387

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

International Nuclear Information System (INIS)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of "2"2"6Ra and "2"3"2Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

388

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

389

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

391

Principles of photon colliders  

Energy Technology Data Exchange (ETDEWEB)

Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).

1995-02-01

392

Composite vector leptoquarks in e"+e-, #gamma#e, and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study the signals for composite vector leptoquarks in e"+e- colliders (CERN e"+e- collider LEP II, Next Linear Collider, and CERN Linear Collider) through their effects on the production of jet pairs, as well as their single and pair productions. We also analyze their production in #gamma#e and #gamma##gamma# collisions.

393

Advanced distillation curve measurements for corrosive fluids: Application to two crude oils  

Energy Technology Data Exchange (ETDEWEB)

We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. The modifications include a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis) and corrosivity assessment of each distillate fraction. The composition-explicit information is achieved with a new sampling approach that allows precise qualitative as well as quantitative analyses of each fraction, on the fly. We have applied the new method to a variety of fluids, including simple n-alkanes, rocket propellant, gasoline, jet fuels, and a hydrocarbon fluid made corrosive with dissolved hydrogen sulfide. In the current contribution, we present the application of the advanced distillation curve method to two samples of crude oil. A primary motivation behind the work is to precisely measure the distillation curves of these oils using our advanced distillation apparatus; ...

2008-10-15

394

Study of passive films formed on stainless steel surfaces, using Auger spectroscopy  

International Nuclear Information System (INIS)

This paper deals with the characterization of passive films formed on stainless steel (26% Cr and 0 to 3%Mo). The influence of the applied passivation potential and the effect of molybdenum additions to steel upon the composition profiles of passive films formed in an aqueous NaCl solution (3.5% at pH 2.5) are studied. The technique involved is Auger electron spectroscopy combined with ion sputtering. Some electrochemical techniques have been used in conjunction. A quantitative approach of the Auger spectra during the progressive removal of the passive film is described. The peak-to-peak height of the Auger lines are treated in order to yield the atomic fraction of the various elements present in a given subsurface layer. The analytical study of the film by electron spectroscopy indicates that molybdenum plays a part at the metal-oxide interface where this element acts on the chromium diffusion process. This phenomenon, which depends on the imposed potential, may lead to the formation ...

1975-01-01

395

Radiation-enhanced diffusion in amorphous Pd-Cu-Si  

Energy Technology Data Exchange (ETDEWEB)

Diffusion during He/sup +/, Ne/sup +/, and Xe/sup +/ irradiations of trace amounts of Au in melt-spun amorphous Pd/sub 78/Cu/sub 6/Si/sub 16/ has been experimentally investigated. Diffusion constants were measured by following the changes in ion-implanted Au profiles with Rutherford-backscattering spectrometry. Heat treatments and simultaneous irradiations were performed as a function of temperature (533--588 K), ion flux, and ion mass. Total integrated fluences being very small, ion-beam-mixing effects are negligible. More than an order of magnitude enhancement in the diffusion was observed because of irradiations. This enhancement saturates at higher fluxes, the level being independent of ion mass, i.e., independent of collision-cascade parameters. Except at higher temperatures, where the enhancement decreases, the temperature dependence of the diffusion-saturation level is similar to that of the diffusion without irradiation. The data ...

1988-11-01

396

Radiation-enhanced diffusion in amorphous Pd-Cu-Si  

International Nuclear Information System (INIS)

Diffusion during He"+, Ne"+, and Xe"+ irradiations of trace amounts of Au in melt-spun amorphous Pd/sub 78/Cu_6Si/sub 16/ has been experimentally investigated. Diffusion constants were measured by following the changes in ion-implanted Au profiles with Rutherford-backscattering spectrometry. Heat treatments and simultaneous irradiations were performed as a function of temperature (533--588 K), ion flux, and ion mass. Total integrated fluences being very small, ion-beam-mixing effects are negligible. More than an order of magnitude enhancement in the diffusion was observed because of irradiations. This enhancement saturates at higher fluxes, the level being independent of ion mass, i.e., independent of collision-cascade parameters. Except at higher temperatures, where the enhancement decreases, the temperature dependence of the diffusion-saturation level is similar to that of the diffusion without irradiation. The data suggest that vacancylike ...

397

Quantitation of acyl migration during lipase-catalyzed acidolysis, and of the regioisomers of structured triacylglycerols formed  

DEFF Research Database (Denmark)

Various MLM-type (M, medium-chain fatty acids; L, long-chain fatty acids) structured triacylglycerols were produced in pilot- or small-scale packed-bed reactors by lipase-catalyzed acidolysis. The incorporation and acyl migration of octanoic acid were measured by gas chromatography and Grignard degradation, and ranged from 39.0 to 48.7% and 0.6 to 9.3%, respectively. Quantitation of triacylglycerol molecular species was performed by ammonia negative ion chemical ionization (NICI) mass spectrometry (MS). The proportion of ACN (acyl carbon number) 34 species that contained one C-18 fatty acid and two C-8:0, in samples analyzed, varied from 12.5 to 23.2%. The selected regioisomers MLM and MML within the ACN 34 species group were quantified by NICI tandem MS (MS/MS) and were in the range of 97.1 to 98.4% and 1.6 to 2.9%, respectively. There was no correlation between the level of acyl migration during lipase-catalyzed esterification and the level ...

2001-01-01

398

Performance of the gas-jet transport system coupled to the RIKEN gas-filled recoil ion separator GARIS for the 238U (22Ne, 5n)255No reaction  

International Nuclear Information System (INIS)

The performance of the gas-jet transport system coupled to the RIKEN gas-filled recoil ion separator GARIS was investigated using 255No produced in the 238U(22Ne, 5n)255No reaction. Alpha particles of 255No separated with GARIS and transported by the gas-jet system were measured with a rotating wheel apparatus for ? spectrometry under low background condition. The high gas-jet efficiencies of about 75% were independent of the recoil ranges of 255No in the gas-jet chamber. The present results suggest that the GARIS/gas-jet system is a promising tool for the next-generation superheavy element chemistry: (1) the background radioactivities of unwanted reaction products are strongly suppressed, (2) the intense beam is absent in the gas-jet chamber and hence the high gas-jet efficiency is achieved, and (3) the beam-free condition also allows for investigations of new chemical systems. (author)

2008-08-01

399

Non-isothermal oxidation of ceramic nanocomposites using the example of Ti-Si-C-N powder: Kinetic analysis method  

Energy Technology Data Exchange (ETDEWEB)

A method of kinetic analysis applicable to non-isothermal oxidation processes of ceramic nanocomposites is presented using Ti-Si-C-N powder as the substrate. The nanoparticle size and phase composition were determined using high-resolution transmission electron microscopy and X-ray diffraction (XRD). Thermogravimetric measurements were carried out for powder samples in dry air in the temperature range 298-1770 K. The following heating rates were applied: 3, 5, 10, 20 K min{sup -1}. Mass spectrometry was used to analyze gaseous oxidation products and solid products were identified by the XRD technique. The Coats-Redfern equation was applied for the kinetic analysis. For each stage of the oxidation kinetic models, the best accuracy was achieved using a series of criteria, and then the A and E parameters of the Arrhenius equations were estimated. Both linear regression and artificial neural networks were applied in testing kinetic models.

2008-08-15

400

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope holds considerable promise for quality assurance because (1) a permanent record of ...

1978-01-01

401

Implantation damage and anomalous diffusion of implanted boron in silicon through SiO_2 films  

International Nuclear Information System (INIS)

Boron is implanted in crystalline silicon through oxide layers with different thicknesses. The implantation is carried out at various doses and energies of interest in ultra large scale integration (ULSI) application. Rapid thermal annealings (RTA) are used to obtain shallow junctions and electrical activation of the B atoms. However, transient enhanced diffusion induced by implantation damage can be observed. The boron concentration profiles before and after annealing are obtained with secondary ion mass spectrometry (SIMS). It is found that the diffusion transient in the tail region of the boron profile increases with decreasing oxide thickness. Even more, if the implantation damage concerns mostly the oxide, i.e. when the concentration peak is located in this oxide, the oxygen knocked into the silicon substrate could play this way an important role in restricting the boron diffusion, which is good to obtain very shallow junctions. On the other hand, for thinner ...

402

Implantation damage and anomalous diffusion of implanted boron in silicon through SiO[sub 2] films  

Energy Technology Data Exchange (ETDEWEB)

Boron is implanted in crystalline silicon through oxide layers with different thicknesses. The implantation is carried out at various doses and energies of interest in ultra large scale integration (ULSI) application. Rapid thermal annealings (RTA) are used to obtain shallow junctions and electrical activation of the B atoms. However, transient enhanced diffusion induced by implantation damage can be observed. The boron concentration profiles before and after annealing are obtained with secondary ion mass spectrometry (SIMS). It is found that the diffusion transient in the tail region of the boron profile increases with decreasing oxide thickness. Even more, if the implantation damage concerns mostly the oxide, i.e. when the concentration peak is located in this oxide, the oxygen knocked into the silicon substrate could play this way an important role in restricting the boron diffusion, which is good to obtain very shallow junctions. On the other hand, for thinner ...

1993-07-16

403

Guideline for sampling and analysis of 'tars' and particles in biomass producer gases  

Energy Technology Data Exchange (ETDEWEB)

The further development of a Guideline (formerly Protocol) for sampling and analysis of 'tars' from biomass producer gases is reported. This Guideline is being developed as a project within the European Fifth Framework Programme with additional partners from Switzerland and North-America. In this paper an outline and the principle of the Guideline are given. The Guideline is based on isokinetic sampling of particles and 'tar' from the main producer gas duct, particle filtration at high temperature, gas cooling in a liquid quench, 'tar' absorption in a solvent at low temperatures, an optional backup adsorber, and flow measurement and control. The Guideline gives a definition for 'Gravimetric tar' which is the 'tar' number to be determined by the Guideline. Also, the Guideline gives procedures for compound analysis by gas chromatography - mass spectrometry ...

2000-07-01

404

Enhanced MALDI-TOF MS Analysis of Phosphopeptides Using an Optimized DHAP/DAHC Matrix  

Science.gov (United States)

Selecting an appropriate matrix solution is one of the most effective means of increasing the ionization efficiency of phosphopeptides in matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). In this study, we systematically assessed matrix combinations of 2, 6-dihydroxyacetophenone (DHAP) and diammonium hydrogen citrate (DAHC), and demonstrated that the low ratio DHAP/DAHC matrix was more effective in enhancing the ionization of phosphopeptides. Low femtomole level of phosphopeptides from the tryptic digests of ?-casein and ?-casein was readily detected by MALDI-TOF-MS in both positive and negative ion mode without desalination or phosphopeptide enrichment. Compared with the DHB/PA matrix, the optimized DHAP/DAHC matrix yielded superior sample homogeneity and higher phosphopeptide measurement sensitivity, particularly when multiple phosphorylated peptides were assessed. Finally, the DHAP/DAHC matrix was ...

2010-01-01

405

Electron affinity of strontium  

Energy Technology Data Exchange (ETDEWEB)

We have observed a threshold in the electron photodetachment cross section of {sup 88}Sr{sup {minus}} ions at a photon energy {ital h}{nu}=1.820 eV and assign it to a {ital p}-wave transition from the 5{ital s}{sup 2}5{ital p}{sup 2}{ital P} ground state in Sr{sup {minus}} to the 5{ital s}5{ital p}{sup 3}{ital P} state in neutral Sr. The measurement was made with a new technique combining the tunable laser photodetachment threshold method with accelerator mass spectrometry. We determine for the first time the electron affinity of Sr to be 48{plus_minus}6 meV, much smaller than predicted in recent calculations. The {sup 2}{ital P}{sub 1/2}-{sup 2}{ital P}{sub 3/2} fine splitting of the Sr{sup {minus}} ground state is estimated to be 26{plus_minus}8 meV.

1995-07-17

406

Determination of trace elements in Syrian medicinal plants and their infusions by energy dispersive X-ray fluorescence and total reflection X-ray fluorescence spectrometry  

Energy Technology Data Exchange (ETDEWEB)

X-ray fluorescence (XRF) and total-reflection X-ray fluorescence (TXRF) techniques suited well for a multi-element determination of K, Ca, Mn, Fe, Cu, Zn, Rb, and Sr in some Syrian medicinal plant species. The accuracy and the precision of both techniques were verified by analyzing the Standard Reference Materials (SRM) peach-1547 and apple leaves-1515. A good agreement between the measured concentrations of the previously mentioned elements and the certified values were obtained with errors less than 10.7% for TXRF and 15.8% for XRF. The determination of Br was acceptable only by XRF with an error less than 24%. Furthermore, the XRF method showed a very good applicability for the determination of K, Ca, Mn, Fe, Cu, Zn, Rb, Sr, and Br in infusions of different Syrian medicinal plant species, namely anise (Anisum vulgare), licorice root (Glycyrrhiza glabra), and white wormwood (Artemisia herba-alba)

2009-07-15

407

Copper-65-absorption by men fed intrinsically and extrinsically labeled whole wheat bread  

International Nuclear Information System (INIS)

Six men were fed a diet composed of conventional foods with all bread as whole wheat bread. Intrinsically labeled "6"5Cu bread (containing 6.5 ppm Cu and 48 atom % "6"5Cu) was substituted for unlabeled bread for 3 days, and stools were collected for 24 days. Extrinsically labeled bread was then substituted for 3 days and another 24-day stool collection made. "6"5Cu excretion was measured by mass spectrometry. Mean Cu intake was 1.10 mg of Cu/day. Average Cu balance was /minus/0.06 /+-/ 0.08 mg/day. Average absorption of the intrinsic copper was 72.2 /+-/ 9.3% and of extrinsic Cu 64.2 /+-/ 5.8%. The ratio of extrinsic to intrinsic absorption was 0.906 /+-/ 0.164. Absorption of intrinsic and extrinsic tracers did not differ significantly (p > 0.05) by a paired t-test, and the ratio (E/I) was not significantly different from 1. Use of extrinsic Cu tracers to assess Cu absorption is supported by these results.

408

Studies on gamma irradiated medicinal plants and spices (1): Myristica argentea, Myristica fragrans, Coriandrum sativum and Foeniculum vulgare  

Energy Technology Data Exchange (ETDEWEB)

Medicinal plants i.e. dried seeds of myristica argentea, myristica fragrans, coriandrum sativum and foeniculum vulgare were stored for 0 and 6 months, with and without gamma irradiation at 5 kGy. No detectable changes were seen in infrared and UV spectra, GLC chromatograms and refraction indices of steam distilled, essential oils from the irradiated medicinal plants. The same results were also obtained from irradiated samples stored for 6 months at ambient conditions. Storage for 6 months caused significant changes in the gas liquid chromatograms and UV spectra of all samples compared to non-stored samples. The moisture content of all samples packed in polyethylene bags seems to be constant after 6 months of storage. No measurable changes were found in the amount of essential oil content caused by irradiation.

1981-10-01

409

Spatial distribution of IGC-30 Ge-detector's efficiency  

International Nuclear Information System (INIS)

The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).

1993-12-02

410

Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR  

International Nuclear Information System (INIS)

This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)

2006-11-13

411

Rare B decays  

Energy Technology Data Exchange (ETDEWEB)

The current status of rare B decays is reviewed based on recent observation of the penguin-diagram decay B {yields} K{sup *}{gamma} at CLEO. Rare B decays provide valuable information on the Standard Model parameters, and also could be a source of direct CP violation. It is emphasized that new physics beyond the Standard Model can appear in rare B decays, in some cases more drastically than in the CP Asymmetry of the B system. Inclusive measurement of the radiative transition b {yields} s{gamma} is promising. Hadronic penguin modes are very close to being observed at CLEO, and a discovery might be just around the corner. (author). 48 refs., 6 figs., 4 tabs.

1994-12-31

412

Radiosterilization of drugs in aqueous solutions may be achieved by the use of radioprotective excipients  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to assess the feasibility of radiosterilization of drugs aqueous solutions and to evaluate the effects of some additives, such as mannitol, nicotinamide and pyridoxine, which might protect the drug from degradation. Metoclopramide was selected as a model drug. The structures of the degradation products were determined to gain insight on the radiolysis mechanisms in aqueous solution in order to design strategies to lower the drug degradation.Metoclopramide hydrochloride aqueous solutions with and without excipients were irradiated either with gamma rays or high-energy electrons. HPLC-DAD was used to measure the loss of chemical potency and to quantify the degradation products which were also characterized by LC-APCI-MS-MS. Metoclopramide recovery for gamma and elec...

2008-01-01

413

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...

2006-10-29

414

Indirect Dark Matter Signals from EGRET and PAMELA compared  

CERN Document Server

Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. The excess of diffuse Galactic Gamma Rays from EGRET shows all the features expected from DMA. The new precise measurements of the antiproton and positron fractions from PAMELA are compared with the EGRET excess. It is shown that the charged particles are strongly dependent on the propagation model used. The usual propagation models with isotropic propagation models are incompatible with the recently observed convection in our Galaxy. Convection leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in the halo to outer space. It is shown that such anisotropic propagation models including convection prefer a contribution from DMA for the ...

2009-01-01

415

Fuel element powers, STVU masses, and burnups from gamma-scanning data: Preliminary analysis of irradiated ORR (Oak Ridge Research Reactor) LEU fuel elements  

Energy Technology Data Exchange (ETDEWEB)

Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.

1988-01-01

416

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

417

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

418

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

419

Effect of #gamma#-irradiation on commercial polypropylene based mono and multi-layered retortable food packaging materials  

International Nuclear Information System (INIS)

Irradiation processing of food in the prepackaged form may affect chemical and physical properties of the plastic packaging materials. The effect of #gamma#-irradiation doses (2.5-10.0 kGy) on polypropylene (PP)-based retortable food packaging materials, were investigated using Fourier transform infrared (FTIR) spectroscopic analysis, which revealed the changes happening to these materials after irradiation. The mechanical properties decreased with irradiation while oxygen transmission rate (OTR) was not affected significantly. Colour measurement indicated that Nylon 6 containing multilayer films became yellowish after irradiation. Thermal characterization revealed the changes in percentage crystallinity.

2007-07-01

420

Dislocation pinning in electron-irradiated copper as a function of electron energy and irradiation  

Science.gov (United States)

Dislocation priming measurements were performed in the kHz range in ASARCO copper. The samples and irradiation facilities are constructed so as to allow successive irradiation of samples both with electrons and gamma rays. The gamma rays were produced by stopping 2.8-MeV electrons in a gold target. The change of the type of irradiation could be achieved without any handling of the sample. Thus it is possible to detect rather small differences between the two types of irradiation. Recovery experiments at 400 deg K after 75 deg K irradiation and pinning rates during irradiation at 400 deg K and 75 deg K were made. (GE)

1973-01-01

421

Measurement and interpretation of delayed photoneutron effects in multizone criticals with partial D{sub 2}O moderation  

Energy Technology Data Exchange (ETDEWEB)

The effective fraction of delayed photoneutrons ({beta}{sup ph}) has been theoretically defined and experimentally determined in various different configurations of the LWR-PROTEUS critical facility. The peculiarity lies in the fact that the reactor has D{sub 2}O in only one of the four fuelled zones, thus D({gamma},n)H reactions take place mainly in this region. The work is divided into three parts. The first part is devoted to the description of the LWR-PROTEUS facility and to the measurements of {beta}{sup ph}. These experimental values are derived from standard inverse-kinetics analysis of neutron flux decay experiments for each of seven different configurations, with nine additional groups of neutron precursors to account for photoneutron effects. In the second part, the coupled neutron and gamma Boltzmann equations are reduced to exact point kinetics equations using the photon infinite-velocity approximation, and then ...

2003-11-01

422

Accelerator aspects of #gamma#-#gamma# colliders  

International Nuclear Information System (INIS)

There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

423

Studies on sup(99m)Tc-pertechnetate from the MEK solvent extraction generator  

International Nuclear Information System (INIS)

Analysis by gas chromatography-mass spectrometry and high performance liquid chromatography has revealed organic residues in sup(99m)Tc-pertechnetate obtained from "9"9Mo-molybdate by extraction, using the organic solvent methylethylketone (MEK). The organic residues have been identified as either (i) low molecular weight carbonyl compounds such as formaldehyde, acetaldehyde and acetone, presumably caused by the effects of #gamma#-radiation on MEK, or (ii) condensation products resulting from the action of strong alkali on MEK during the extraction process. The quantities of organic residues varied from batch to batch of extracted pertechnetate; up to 40 #mu# mL"-"1 was found. When these compounds were tested, in rats, by addition to a pyrophosphate bone-seeking radiopharmaceutical, the tissue distribution was not significantly different from that in the control, which contained no added compound. Assay for "9"9Tc in MEK-derived pertechnetate ...

424

Spectroscopic characterization of alkane radical cations: Pt. 1  

International Nuclear Information System (INIS)

Radical cations of various 3-methylalkanes (C_6-C_1_4) have been produced and stabilized by #gamma#-irradiation of the corresponding neutral compounds in saturated chlorofluorocarbon and perfluorocarbon matrices at 77 K. The perfluorocarbon matrices appeared more suitable for studies of the lighter radical cations, whereas the chlorofluorocarbon matrices were more suited for studies of the heavier radical cations; intermediary cations could be studied in both types of matrices. After irradiation, electronic absorptions associated with both the matrix and the alkane additive were observed. Pure spectra of the 3-methylalkane radical cations were obtained by difference spectrometry, after selective elimination of these cations by illumination. The electronic absorption spectra of the 3-methylalkane radical cations consist in all cases of a single broad absorption band. The spectral position of this band shifts to longer wavelengths with increasing ...

1989-01-01

425

Environmental radioactivity on Suape (PE) estuary: impact of the installation of an oil refinery  

Energy Technology Data Exchange (ETDEWEB)

Nowadays there is a growing interest in the study of natural radioactivity levels, mainly of radionuclides; {sup 238}U, {sup 226}Ra, {sup 232}Th, {sup 40}K, and {sup 210}Pb present in the environment. The environmental radioactivity control is very important to obtain information on exposure of humans and vegetables to potential sources on natural radioactive occurrences. Industrial processes involving mining and extraction and production of oil foster concentration of radionuclides, contributing to the occurrence of what is known as 'TENORM' - Technologically Enhanced Naturally Occurring Radioactive Material. This work aims to assess the environmental radiological impact on the estuarine area of the Industrial Park of SUAPE, due the installation of an oil refinery and the consequent introduction on the environment of natural radioactive materials from other regions in that area. The radioisotopes {sup 238}U, {sup 226}Ra, {sup 232}Th , {sup 40}K and {sup 210}Pb were ...

2009-07-01

426

Characterization and Source Term Assessments of Radioactive Particles from Marshall Islands Using Non-Destructive Analytical Techniques  

Energy Technology Data Exchange (ETDEWEB)

A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and ...

2005-06-11

427

Excited leptons and quarks at. gamma. gamma. /. gamma. e colliders  

Energy Technology Data Exchange (ETDEWEB)

We discuss the search of excited leptons and quarks with spin 1/2 at {gamma}{gamma} and at {gamma}e colliders. We show that {gamma}{gamma} colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l{sup *}l{gamma} transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).

1992-02-06

428

Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum  

CERN Document Server

Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.

2010-01-01

429

Measurement of level lifetimes in the ps range and model interpretations for neutron-rich A #approx =# 100 nuclei  

International Nuclear Information System (INIS)

The nuclear structure of A #propor to# 100 nuclei has been studied in the frame of this thesis with a recently developed #beta# - #gamma# - #gamma# triple coincidence fast timing technique and different models such as shell model, hydrodynamic model, Nilsson and particle-rotor models. This technique which allows the measurement of the level lifetimes in the ps range has been applied at JOSEF at the research reactor DIDO of KFA Juelich in studes of the short-lived neutron-rich nuclei in the A #approx =# 100 region. Lifetimes of level in "9"6,"9"8,"1"0"0 ZR, "9"9,"1"0"1-"1"0"4 Nb, "1"0"0-"1"0"5 Mo have been measured, which are in many cases completely new, and otherwise more precise than previously published data. From the lifetimes of the members of rotational bands, the size of the nuclear deformations has been deduced. (orig./HSI).

430

Measurement of "1"0"1Tc Half-Life  

International Nuclear Information System (INIS)

75 mg (NH_4)_6Mo_7O_24 #centre dot# 4H_2O solution was irradiated for 20 min in miniature neutron source reactor (MNSR) and cooled for 12 min. In the conditions of 0.8 mol/L HNO_3, phase ratio 1:1, the solution of "1"0"1Tc sample was extracted twice with #alpha#-benzoin oxime/ethyl acetate phase to remove "1"0"1Mo and a radiochemically pure and carrier-free "1"0"1Tc product was obtained. The half-life of "1"0"1Tc was accurately measured with a HPGe #gamma#-detector by following 306.8 keV #gamma#-ray about 150 min, and processed the data by three methods, R-value method, iterative method and translation method. Five parallel measurments gave a half-life (14.02 #+-# 0.01) min (n=5) for "1"0"1Tc. (authors)

2009-11-01

431

Limits on Anomalous Trilinear Gauge Couplings in Zgamma Events from ppbar Collisions at sqrt{s} = 1.96 TeV  

CERN Document Server

Using Zgamma candidate events collected by the CDF detector at the Tevatron Collider, we search for potential anomalous (non-standard-model) couplings between the Z boson and the photon. At the hard scatter energies typical of the Tevatron, standard model Zgamma couplings are too weak to be detected by current experiments; hence any evidence of couplings indicates new physics. Measurements are performed using data corresponding to an integrated luminosity of 4.9 /fb in the Z -> nunubar decay channel and 5.1 /fb in the Z -> l^+l^- (l=mu, e) decay channels. The combination of these measurements provides the most stringent limits to date on Zgamma trilinear gauge couplings. Using an energy scale of Lambda = 1.5 TeV to allow for a direct comparison with previous measurements, we find limits on the CP-conserving parameters that describe Zgamma couplings to be |h_3^{\\gamma,Z}| < 0.017 and ...

2011-01-01

432

Heat capacities between 1.5 and 16 K and superconductivity of V/H and Nb/H alloys  

International Nuclear Information System (INIS)

Molar heat capacities have been measured for VHsub(n) and NbHsub(n) with n up to 1.93 at temperatures between 1.5 and 16 K. The height of the peak in plots of the electronic specific heat, indicating superconductivity, diminishes with increasing hydrogen content in the #alpha# + #beta# two-phase region, and can be taken as a measure of the fractional amount of #alpha#-phase present (lever-rule). In NbHsub(n) accordingly, the two-phase region presumably extends up to n = approximately 0.9 at helium temperatures. No hydride phase, including VH_2 and NbH_2, showed superconductivity above 1.5 K. The measured #gamma#-coefficients of the V/H-alloys agree with APW band-structure calculations for V metal in the range 5 =< nsub(e) =< 7 of band electron concentration. They coincide with the #gamma#-coefficients of V/Cr-alloys reported in the literature. Hence VHsub(n) represents another ...

1977-05-01

433

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint ...

2009-06-07

434

Measurement of. beta. decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 less than or equal toA less than or equal to106 and A=109. Messung von Beta-Zellverfallsenergien kurzlebiger, neutronenreicher Atomkerne im Massenbereich 101 less than or equal toA less than or equal to106 und A=109  

Energy Technology Data Exchange (ETDEWEB)

Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values in keV). For the ...

1986-10-31

435

Measurement of #beta# decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 #<=# A #<=# 106 and A=109  

International Nuclear Information System (INIS)

Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma ...

436

The measurement of the fission product ratios, {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuel by gamma scanning method  

Energy Technology Data Exchange (ETDEWEB)

We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.

1997-10-01

437

The measurement of the fission product ratios, "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuel by gamma scanning method  

International Nuclear Information System (INIS)

We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.

1988-09-18

438

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light ...

1992-10-25

439

Measurement of $\\phi$(1020) meson leptonic width with CMD-2 detector at VEPP-2M Collider  

CERN Document Server

The $\\phi$(1020) meson leptonic width has been determined from the combined analysis of 4 major decay modes of the resonance ($\\phi\\to K^+ K^-,K^0_LK^0_S,\\pi^+\\pi^-\\pi^0,\\eta\\gamma$) studied with the CMD-2 detector at the VEPP-2M $e^+e^-$ collider. The following value has been obtained: $\\Gamma(\\phi\\to e^+e^-) = 1.235\\pm 0.006\\pm 0.022$ keV. The $\\phi(1020)$ meson parameters in four main decay channels have been also recalculated: $B(\\phi\\to K^+K^-) = 0.493\\pm 0.003\\pm 0.007$, $B(\\phi\\to K_LK_S) = 0.336\\pm 0.002\\pm 0.006$, $B(\\phi\\to\\pi^+\\pi^-\\pi^0) = 0.155\\pm 0.002\\pm 0.005$, $B(\\phi\\to\\eta\\gamma) = 0.0138\\pm 0.0002\\pm 0.0002$.

2010-01-01

440

Characterization of iron nitrides prepared by spark erosion, plasma nitriding, and plasma immersion ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The effect of the nitrogen uptake in {alpha}-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic {alpha}-Fe phase (50%). The 20% of specimen volume form {alpha}'-Fe and {alpha}''-Fe{sub 16}N{sub 2} phases. The last 30% occupy the {gamma}'-Fe{sub 4}N, ferro- and paramagnetic {epsilon} phases, and {gamma}-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into {alpha}-iron particles which results in the formation of paramagnetic {epsilon}({zeta})-Fe{sub 2}N phase. This phase ...

2001-09-01

441

Characterization of iron nitrides prepared by spark erosion, plasma nitriding, and plasma immersion ion implantation  

International Nuclear Information System (INIS)

The effect of the nitrogen uptake in #alpha#-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic #alpha#-Fe phase (50%). The 20% of specimen volume form #alpha#'-Fe and #alpha#''-Fe_1_6N_2 phases. The last 30% occupy the #gamma#'-Fe_4N, ferro- and paramagnetic #epsilon# phases, and #gamma#-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into #alpha#-iron particles which results in the formation of paramagnetic #epsilon#(#zeta#)-Fe_2N phase. This phase also dominates the surface of #alpha#-iron specimen ...

2001-09-01

442

Backward pion photoproduction  

Energy Technology Data Exchange (ETDEWEB)

We present a systematic analysis of backward pion photoproduction for the reactions {gamma}p{yields}{pi}{sup 0}p and {gamma}p{yields}{pi}{sup +}n. Regge phenomenology is applied at invariant collision energies above 3GeV in order to fix the reaction amplitude. A comparision with older data on {pi}{sup 0}- and {pi}{sup +}-photoproduction at {theta}=180 indicates that the high-energy limit as given by the Regge calculation could be reached possibly at energies of around {radical}(s){approx_equal}3 GeV. In the energy region of {radical}(s){<=}2.5 GeV, covered by the new measurements of {gamma}p{yields}{pi}{sup 0} p differential cross-sections at large angles at ELSA, JLab, and LEPS, we see no clear signal for a convergence towards the Regge results. The baryon trajectories obtained in our analysis are in good agreement with those given by the spectrum of excited baryons. (orig.)

2009-04-15

443

"Discrepant hardenings" in cosmic ray spectra: a first estimate of the effects on secondary antiproton and diffuse gamma-ray yields  

CERN Document Server

Recent data from CREAM seem to confirm early suggestions that primary cosmic ray spectra at few TeV/nucleon are harder than in the 10-100 GeV range. Also, helium and heavier nuclei spectra appear systematically harder than the proton fluxes at corresponding energies. We note here that if the measurements reflect intrinsic features in the interstellar fluxes, appreciable modifications are expected in the sub-TeV range for the secondary yields, such as antiprotons and diffuse gamma-rays. Presently, this effect represents a systematic error in the extraction of astrophysical parameters as well as for background estimates for indirect dark matter searches. We find that the spectral modifications are appreciable above 100 GeV, and can be responsible for ~30% effects for antiprotons at energies close to 1 TeV or for gamma's at energies close to 300 GeV, compared to currently considered predictions based on simple extrapolation of ...

2010-01-01

444

Advanced distillation curve measurement: Application to a bio-derived crude oil prepared from swine manure  

Energy Technology Data Exchange (ETDEWEB)

We have recently introduced several important improvements in the measurement of distillation curves for complex fluids. This new method is a significant improvement over current approaches, with features including a composition-explicit data channel for each distillate fraction (for both qualitative and quantitative analysis), trace chemical analysis of each distillate fraction, and a corrosivity assessment of each distillate fraction. In the present contribution, we present the application of the advanced distillation curve method to a bio-derived crude oil prepared from swine manure. One motivation behind the work was to precisely measure the distillation curve of the oil derived from swine manure with our advanced distillation apparatus and compare the bio-derived oil to traditional petroleum crude oils. Then, the information content of the bio-derived oil distillation was extended further with the composition-explicit data channel: gas ...

2008-11-15

445

Observation of eta_c(1S) and eta_c(2S) decays to K+ K- pi+ pi- pi0 in two-photon interactions  

CERN Document Server

We study the processes gamma gamma -> K^0_S K+/- pi-/+ and gamma gamma -> K+ K- pi+ pi- pi0 using a data sample of 519.2 fb-1 recorded by the BaBar detector at the PEP-II asymmetric-energy e+e- collider at center-of-mass energies near the Upsilon(nS) (n = 2,3,4) resonances. We observe the eta_c(1S), chi_c0(1P), chi_c2(1P), and eta_c(2S) resonances produced in two-photon interactions and decaying to K+ K- pi+ pi- pi0, with significances of 18.1, 5.7, 5.2, and 5.3 standard deviations (including systematic errors), respectively. We measure the eta_c(2S) mass and width in K^0_S K+/- pi-/+ decays, m(eta_c(2S))=3638.5 +/- 1.5 +/- 0.8 MeV/c^2 and Gamma(eta_c(2S)) = 13.4 +/- 4.6 +/- 3.2 MeV, where the first uncertainty is statistical and the second is systematic. We search for the Z(3930) resonance and find no significant signal. We also provide the two-photon ...

2011-01-01

446

Result analysis on the parameter test of radium specific activity calculation in the tailing of uranium mine No. 794  

International Nuclear Information System (INIS)

This paper first introduces the calculating method of radium specific activity to determine the radon emanation rate of tailing of uranium mine No. 794, the method needs two parameters: radon emanation coefficient and radon diffusion coefficient. According to the measured results of parameters and the contrast between radium specific activity of indoor chemical analysis of field sample and field gamma-ray spectra, the authors discuss the variation rules and characteristics of radon emanation coefficient and radon diffusion coefficient, and the best climate and seasons for measuring these parameters in northern China, and finally summarize the characteristics of this method through analyzing measured results. (authors)

2006-09-01

447

New neutron capture and total cross section measurements on {sup 88}Sr and their impact on s-process nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

The authors have made new and improved measurements of the neutron capture and total cross sections of {sup 88}Sr at the Oak Ridge Electron Linear Accelerator (ORELA). Improvements over previous measurements include a wider incident neutron energy range, the use of metallic rather than carbonate samples, better background subtraction, reduced sensitivity to sample-dependent backgrounds, and better pulse-height weighting functions. Because of its small cross section, the {sup 88}Sr(n,{gamma}) reaction is an important bottleneck during the s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. They describe the experimental procedures, compare the results to previous data, and discuss their astrophysical impact.

1998-11-01

448

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

449

Multiple ordered phases in the filled skutterudite compound PrOs4As12  

Energy Technology Data Exchange (ETDEWEB)

Magnetization, specific heat, and electrical resistivity measurements were made on single crystals of the filled skutterudite compound PrOs{sub 4}As{sub 12}. Specific heat measurements indicate an electronic specific heat coefficient {gamma} {approx} 50-200 mJ/mol K{sup 2} at temperatures 10 K {le} T {le} 18 K, and {approx} 1 J/mol K{sup 2} for t {le} 1.6 K. Magnetization, specific heat, and electrical resistivity measurements reveal the presence of two, or possibly three, ordered phases at temperatures below {approx} 2.3 K and in fields below {approx} 3 T. The low temperature phase displays antiferromagnetic characteristics, while the nature of the ordering in the other phase(s) has yet to be determined.

2006-03-20

450

Measurement of the total photoabsorption cross section on a proton in the energy range 600?1500 MeV at the GRAAL  

British Library Electronic Table of Contents (United Kingdom)

The total photoabsorption cross section on a free proton was measured at the GRAAL facility in the energy range E ? = 600?1500 MeV. The large-aperture LAGRAN?E detector and a liquid hydrogen target were used in the experiment performed with a back-scattered Compton gamma beam. To improve the accuracy, two alternative methods were employed. First, a subtraction method of using empty-target measurements allowed the cross section ? tot to be evaluated directly because of a low level of the electromagnetic background. Second, an algorithm for evaluating ? tot on the basis of summing the dominating partial cross sections was developed. Experimental results obtained for ? tot by the two methods are compared with existing data.

2008-01-01

451

First measurement of ADS parameters using B- -> D0K- decays in hadron collisions  

CERN Document Server

Measurements of branching fractions and CP-asymmetries of B^{-} \\rightarrow D^{0}K^{-} modes allow a theoretically-clean extraction of the CKM angle \\gamma. The method proposed by Atwood, Dunietz and Soni (ADS) makes use of a decay chain where color and Cabibbo suppression interfere, which produces large CP-violating asymmetries. The CDF experiment reports the first measurement at a hadron collider of branching fractions and CP-asymmetries of suppressed B^{-} \\rightarrow D^{0}h^{-} signals, where h is \\pi or K. Using 5.0 fb^{-1} of data we found a combined significance exceeding 5\\sigma and we determined the ADS parameters with accuracy comparable with B-factories.

2011-01-01

452

Development of a radon standard source  

Energy Technology Data Exchange (ETDEWEB)

The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density ...

2005-06-11

455

{sup 252}Cf-source-driven frequency analysis measurements with subcritical arrays of PWR fuel pins  

Energy Technology Data Exchange (ETDEWEB)

Experiments with fresh PWR fuel assemblies were performed to assess the {sup 252}Cf-source-driven frequency analysis method for measuring the subcriticality of spent fuel. The measurements at the Babcox and Wilcox Critical Experiments Facility mocked up between 17x17 fuel pins (single assembly) and a full array of 4961 fuel pins (about 17 fuel assemblies) in borated water with a fixed B concentration. For the full array, the B content of the water was varied from 1511 at delayed criticality to 4303 ppM. Measurements were done for various source-detector-fuel pin configurations; they showed high sensitivity of frequency analysis parameters to B content and fissile mass. Parameters such as auto and cross power spectral densities can be calculated directly by a more general model of the Monte Carlo code (MCNP-DSP). Calculation-measurement comparisons are presented. This model permits the validation of ...

1996-08-01

456

Use of a predictor for total body potassium content: application to nutrition and hypertension  

International Nuclear Information System (INIS)

Total body potassium (TBK), measured at different institutions, has no reference standard for comparison. A useful reference formula, however, based on body size and age, has been derived at the Brookhaven National Laboratory. This formula was used to help calibrate a simple whole body counter for measuring total potassium and applied to nutrition and hypertension studies. A sodium iodide detector was used for counting gamma rays emitted by potassium-40 to estimate TBK. The mean ratio (+/- S.D.) of adjusted TBK measurements to predicted values was 1.002 +/- 0.047. The ratio of lean body mass estimated by the TBK measurement to that derived from skin fold thickness was 1.069 +/- 0.056. In hypertensives on low dose thiazide, the ratio of TBK measurements to predicted values was 0.994 +/- 0.052. Thus, our TBK measurements were adjusted in close ...

457

Measurement of inelastic charmonium production at HERA  

Energy Technology Data Exchange (ETDEWEB)

This thesis presents measurements of inelastic photoproduction and electroproduction of J/{psi} mesons in ep scattering at HERA. The data was collected by the H1 detector during the HERA II running and corresponds to an integrated luminosity of L {approx} 166 pb{sup -1} in the photoproduction analysis and L {approx} 315 pb{sup -1} in the electroproduction analysis. In both analyses the elasticity of the J/{psi} meson is restricted to a medium range of 0.3 {<=} z {<=} 0.9. The kinematic range of the photoproduction analysis is defined by Q{sup 2} {approx} 0 GeV{sup 2}, 60 {<=}W{sub {gamma}}{sub p}{<=} 240 GeV and P{sub {tau}}{sub ,{psi}}{>=} 1 GeV{sup 2}, whereas the electroproduction analysis is restricted to 3.6 {<=} Q{sup 2} {<=} 100 GeV{sup 2}, 50 {<=}W{sub {gamma}}{sub p}{<=} 225 GeV, and P{sup *}{sub {tau}}{sub ,} {sub {psi}} {>=} 1 GeV. Here P{sup ...

2008-09-15

458

Beta-delayed proton emission: a new series of precursors, and the measurement of 10"-"1"6 s nuclear lifetimes  

International Nuclear Information System (INIS)

The results of investigation into a new series of Z-even nuclei - precursors of delayed protons (PDP) -"6"5Ge, "8"9Se, "9"3Kr, "8"1Zr, and "8"5Mo are presented. PDP were obtained by irradiation of targets in the following reactions: Zn(He, 2n) "6"5Ge, 22 MeV; "4"0Ca("3"2S, 2 pn) "1"9Se, 100 MeV; "6"0Ni ("1"60, 3 n), "7"3Kr, 75 MeV; "5"2Cr ("3"2S, 3n)"8"1Zr, 110 MeV; "5"6Fe("3"2S, 3n)"8"5Mo, 120 MeV. The targets (self-sustaining foils of thickness approximately 1.2 mg/cm"2) were placed at an angle of 15 deg to the direction of the ion beam. Upon irradiation targets were moved downwards into a measuring position. The spectra of protons, X and gamma-rays, and also the spectra of p - x, p-#gamma#, x - #gamma# coincidences accompanying the decay of "6"5Ge, "6"9Se,"7"3Kr and "8"1Zr, and "8"5Mo were measured. The measured half-lives are equal, to 31.5+-1.9, 27.3+-0.5, ...

459

Study of scalar leptons at the TESLA Photon Collider  

International Nuclear Information System (INIS)

In this thesis, the potential to discover supersymmetric signatures in both e"+e"- and #gamma##gamma# colliders evaluated with a Monte Carlo analysis, is discussed. The analysis was focused on the detection of muons, essentially. First, we study the detection of #mu#"+_R#mu#"-_R in e"-e"+ collisions, whose purpose is the measurement of the #mu#_R mass. It was found that an uncertainty of 0.11 GeV (stat) can be achieved. Under the assumption of the real conditions of the ILC photon collider, a study covering the detection of #mu#"+_R#mu#"-_R and #mu#"+_L#mu#"-_L pairs for #sq root#(s_e_"-_e_"+)=0.5 and 0.6 TeV was performed. According to the simulation, a statistical error for the branching ratios of #mu#"#+-#_L#->##chi#"0_1#mu#"#+-# of 0.98% and #mu#"#+-#_L#->##chi#"0_2#mu#"#+-# of 3.97% can be reached. In order to judge the Monte Carlo results, we have used a technique based on a multidimensional fit to evaluate the impact of the ...

460

High-efficiency Resonant rf Spin Rotator with Broad Phase Space Acceptance for Pulsed Polarized Cold Neutron Beams  

Energy Technology Data Exchange (ETDEWEB)

High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on adiabatic fast passage. We discuss the design of the spin rotator and describe two types of ...

2008-08-01

461

#sigma#_e_e_#gamma#_#gamma#"t"o"t at e"+e"- colliders  

International Nuclear Information System (INIS)

In this talk I briefly summarize different models for #sigma#_2_#gamma#"t"o"t (e"+e"-#->##gamma##gamma##->#hadrons) and contrast model predictions with the data. I will then discuss the capability of the future e"+e"- and #gamma##gamma# colliders to distinguish between various models and end with an outlook for future work.

2001-07-09

462

Chargino production at high energy {gamma}{gamma} colliders with polarized beams  

Energy Technology Data Exchange (ETDEWEB)

We investigate the chargino production process {gamma}{gamma} {yields} (W-tilde){sup +}(W-tilde){sup -} at high energy {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy {gamma} beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background {gamma}{gamma} {yields} W{sup +}W{sup -}. (author).

1995-05-01

463

Chargino production at high energy #gamma##gamma# colliders with polarized beams  

International Nuclear Information System (INIS)

We investigate the chargino production process #gamma##gamma# #-># (W-tilde)"+(W-tilde)"- at high energy #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy #gamma# beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background #gamma##gamma# #-># W"+W"-. (author).

1995-05-01

464

gamma. /sub 5/ in dimensional regularization  

Energy Technology Data Exchange (ETDEWEB)

By generalizing the algebra satisfied by the ..gamma../sub 5/ matrix, it is possible to give an extension of ..gamma../sub 5/ to d dimensions. We discuss the connection of this scheme to others.

1985-02-07

465

A study of palladium silicide formed by focused ion beam implantation of palladium ions  

Science.gov (United States)

The formation and properties of Pd{sub 2}Si formed by focused ion beam implantation of Pd ions into Si is presented in this thesis. An extensive microstructural study using transmission electron microscopy was undertaken and the as-implanted as well as annealed microstructure is shown. Results of other analysis techniques such as Rutherford back scattering and secondary ion mass spectrometry etc. are also presented. Kinetic information on the growth of Pd{sub 2}Si obtained by both microstructural and resistance measurements indicates that the activation energy for growth of the silicide is around 0.36 to 0.39 eV. This can be compared with the normally reported value of 1.5 eV for Pd{sub 2}Si formed by annealing thin film Pd on Si. The growth of the silicide was found to follow t{sup 1/2} kinetics. Microstructural observation of the as-implanted samples showed extensive in-situ formation of Pd{sub 2}Di and also surprisingly few defect ...

1989-01-01

466

A study of palladium silicide formed by focused ion beam implantation of palladium ions  

International Nuclear Information System (INIS)

The formation and properties of Pd_2Si formed by focused ion beam implantation of Pd ions into Si is presented in this thesis. An extensive microstructural study using transmission electron microscopy was undertaken and the as-implanted as well as annealed microstructure is shown. Results of other analysis techniques such as Rutherford back scattering and secondary ion mass spectrometry etc. are also presented. Kinetic information on the growth of Pd_2Si obtained by both microstructural and resistance measurements indicates that the activation energy for growth of the silicide is around 0.36 to 0.39 eV. This can be compared with the normally reported value of 1.5 eV for Pd_2Si formed by annealing thin film Pd on Si. The growth of the silicide was found to follow t"1"/"2 kinetics. Microstructural observation of the as-implanted samples showed extensive in-situ formation of Pd_2Di and also surprisingly few defect structures. A heat transfer model ...

467

Whole-body counting in the Marshall Islands  

Energy Technology Data Exchange (ETDEWEB)

In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 the Rongelap people have been self-exiled ...

1991-01-01

468

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

Energy Technology Data Exchange (ETDEWEB)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino ...

1993-12-31

469

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

International Nuclear Information System (INIS)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino ...

470

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation ...

1999-07-01

471

The lightest Higgs Boson of mSUGRA, mGMSB and mAMSB at Present and Future Colliders Observability and Precision Analyses  

CERN Document Server

We investigate the physics of the lightest CP-even MSSM Higgs boson at the Tevatron, the LHC, a linear e+e- collider, a gamma gamma collider and a mu+mu- collider. The analysis is performed in the three most prominent soft SUSY-breaking scenarios, mSUGRA, mGMSB and mAMSB. For all colliders the observability and parameter regions with suppressed production cross sections (compared to a SM Higgs boson with the same mass) are investigated. For the lepton and photon colliders the potential is analyzed of precision measurements of the branching ratios of the light CP-even Higgs boson for obtaining indirect bounds on the mass of the CP-odd Higgs boson and the high-energy parameters of the soft SUSY-breaking scenarios. In regions of the parameter space where the LHC can detect the heavy Higgs bosons, precision measurements of the properties of the light Higgs boson at the linear collider can provide valuable ...

2003-01-01

472

Radiochemical detector cross section sensitivity studies in the A approx. = 90 mass region  

Energy Technology Data Exchange (ETDEWEB)

The use of radiochemical detectors in the A approx. = 90 mass region to measure 14 MeV neutron fluences is investigated from the standpoint of cross section sensitivities. Specifically, /sup 90/Zr and /sup 89/Y neutron-induced cascades leading to the production of /sup 89/Zr, /sup 88/Zr, /sup 88/Y, and /sup 87/Y are studied in a one-energy-group approximation, and the sensitivities of the measured ratios R/sub Z/ = /sup 88/Zr//sup 89/Zr and R/sub Y/ = /sup 87/Y//sup 88/Y to the input cross sections are delineated. The most sensitive cross section in each cascade is the cross section that dominates the production of the final isotope in the chain. Only one of the isomeric levels in /sup 90/Zr contributes importantly to the Zr cascade. Burnback (n,..gamma..) and burnup (n,p) reactions are also considered. The (n,..gamma..) effects are small, but (n,p) effects can be substantial due to low energy ...

1984-04-05

473

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

474

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

475

Evidence of polarisation in the prompt gamma-ray emission from GRB 930131 and GRB 960924  

CERN Document Server

The true nature of the progenitor to GRBs remains elusive; one characteristic that would constrain our understanding of the GRB mechanism considerably is gamma-ray polarimetry measurements of the initial burst flux. We present a method that interprets the prompt GRB flux as it Compton scatters off the Earth's atmosphere, based on detailed modelling of both the Earth's atmosphere and the orbiting detectors. The BATSE mission aboard the \\textit{CGRO} monitored the whole sky in the 20 keV - 1 MeV energy band continuously from April 1991 until June 2000. We present the BATSE Albedo Polarimetry System (BAPS), and show that GRB 930131 and GRB 960924 provide evidence of polarisation in their prompt flux that is consistent with degrees of polarisation of $\\Pi>35$% and $\\Pi>50$% respectively. While the evidence of polarisation is strong, the method is unable to strongly constrain the degree of polarisation beyond a systematics based estimation. ...

2005-01-01

476

Environmental pollutant isotope measurements and natural radioactivity assessment for North Tushki area, south western desert, Egypt  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is ...

2002-09-01

477

Electronic structure and nesting-driven enhancement of the RKKY interaction at the magnetic ordering propagation vector in Gd_2PdSi_3 and Tb_2PdSi_3  

International Nuclear Information System (INIS)

We present first-time measurements of the Fermi surface and low-energy electronic structure of intermetallic compounds Gd_2PdSi_3 and Tb_2PdSi_3 by means of angle-resolved photoelectron spectroscopy (ARPES). We show that the Fermi surface in both compounds consists of an electron barrel at the #GAMMA# point surrounded by spindle-shaped electron pockets originating from the same band, with the band bottom of both features lying at 0.5 eV below the Fermi level. From the experimentally measured band structure, we estimate the momentum-dependent RKKY coupling strength and demonstrate that it is peaked at the 1/2#GAMMA# K wave vector. Comparison with neutron diffraction data from the same crystals shows perfect agreement of this vector with the propagation vector of the low-temperature in-plane magnetic order, thereby demonstrating the decisive role of the Fermi surface geometry in explaining the complex ...

2009-03-22

478

Determination of the surface properties calcite treated with stearic acid by Inverse Gas Chromatography  

Energy Technology Data Exchange (ETDEWEB)

The values of -{delta}G{sub A}{sup O} of n-alkanes on calcite are lower on the stearic acid treated calcite than on the untreated calcite. The value of -{delta}G{sub A}{sup O} of n-alkanes on calcite increase with increasing carbon numbers of n-alkanes. The values of -{delta}G{sub A}{sup O} measured on the treated calcite are significantly lower than those measured on the untreated calcite. The -{delta}G{sub A}{sup O} of n-alkanes on the treated calcite are close to the heat of liquefaction of n-alkanes. All the experimental values of -{delta}G{sub A}{sup O} of n-alkanes on calcite are larger than theoretical entropy decrease particularly for the higher molecular mass n-alkanes. Thus the important entropy decrease observed upon adsorption can not only be attributed to the loss of one degree of freedom of the adsorbed molecules. The values of {gamma}{sub S}{sup D} of the treated and untreated calcite decrease with increasing ...

1999-10-31

479

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. ...

1988-10-01

480

Sound absorption of tropical woods and their radiation-induced composites  

International Nuclear Information System (INIS)

This is a preliminary study on the sound absorption properties of two tropical hardwoods, Light Red Meranti and Ramin, and their wood-polymer composites. Sound absorption is measured using a standing wave apparatus. The samples are of one thickness (7 mm) and cut longitudinally. Wood-polymer composites are made by impregnating the samples with methyl methacrylate which is polymerized in situ through #gamma#-irradiation. Both woods and their composites are better sound absorbers at higher sound frequencies. With partial impregnation, the absorption coefficients are improved upon particularly in the region between 1-3 kHz. (author).

1988-01-01

481

Simulation of Pulsed Neutron Activation using a CFD code  

International Nuclear Information System (INIS)

Tests for the applicability of a CFD (Computational Fluid Dynamics) code for simulating activity transport in PNA (Pulsed Neutron Activation) fluid measurements have been performed. The CFD code was combined with a Monte Carlo code used for the calculation of the initial activity distribution. The results from the calculations show that it is possible to use CFD for calculation of the activity distribution in PNA. The mainly qualitative results in this work are encouraging and suggest further work. In the continuation of this work a response function for the gamma detector will be calculated so that a PNA time spectrum can be simulated. A more accurate comparison with experimental data can then be performed

2008-09-14

482

Si-JFET devices and related noise behavior under irradiation  

Energy Technology Data Exchange (ETDEWEB)

Monolithic N-channel junction field effect transistors (NJFETs) dc characteristics, small signal parameters and noise have been studied from 300 K down to cryogenic temperatures before and after irradiation with {sup 60}Co {gamma}-rays and fast neutrons (1 MeV). Radiation induced effects on dc parameters and noise are reviewed. Noise spectral density measurements performed at various temperatures have shown that the radiation induces a noise increase which is temperature and frequency dependent. (orig.). 14 refs.

1998-02-01

483

Revisiting light neutralino scenarios in the MSSM  

CERN Document Server

We revisit the case of a light neutralino LSP in the framework of the MSSM. We consider a model with eleven free parameters. We show that all scenarios where the annihilation of light neutralinos rely mainly on the exchange of a light pseudoscalar are excluded by direct detection searches and by Fermi measurements of the gamma-flux from dwarf spheroidal galaxies. On the other hand, we find scenarios with light sleptons that satisfy all collider and astroparticle physics constraints. In this case, the lower limit on the LSP mass is 12.6 GeV. We discuss how the parameter space of the model will be further probed by new physics searches at the LHC.

2011-01-01

484

Radiological hazards in uranium mines and a yellow-cake plant in Turkey  

Energy Technology Data Exchange (ETDEWEB)

Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.

1984-06-01

485

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented. (orig.).

1985-02-01

486

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented.

1985-02-01

487

Nuclear spectroscopy, ch. 8  

International Nuclear Information System (INIS)

Energy level schemes are derived from gamma spectroscopy of several medium-mass deformed nuclei by studying the decay or proton and #alpha# nuclear spectroscopic data. Some new isomeric studies are established among which is the 31 y "1"7"8Hf isomeric state for which Isup(#pi#), K was determined to be 16"+, 16. A four quasi-particle configuration was assigned to this state at 2447.5 +- 2.5 KeV. Atomic masses have been calculated from various measurements and, on the basis of mass formulae extrapolated to neighboring mass regions.

488

Measurement of the Matrix Element for the Decay $\\eta^{\\prime} \\to \\eta \\pi^+\\pi^-$  

CERN Document Server

The Dalitz plot of $\\eta^{\\prime} \\to \\eta \\pi^+ \\pi^-$ decay is studied using $(225.2\\pm2.8)\\times 10^6$ $\\jpsi$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider. With the largest sample of $\\eta^{\\prime}$ decays to date, the parameters of the Dalitz plot are determined in a generalized and a linear representation. Also the branching fraction of $\\jpsi \\to \\gamma \\eta^{\\prime}$ is determined to be $(4.84\\pm0.03\\pm0.24)\\times 10^{-3}$, where the first error is statistical and the second systematic.

2010-01-01

489

Level structure of the doubly-odd /sup 242/Am nucleus  

Energy Technology Data Exchange (ETDEWEB)

The level structure of the doubly-odd /sup 242/Am nucleus was investigated by means of thermal-neutron-capture gamma-ray and conversion electron spectroscopy. Pair, curved-crystal, and ..beta.. spectrometers were used. The data from these measurements, combined with previous direct reaction results, permit us to establish a detailed level scheme including six new well-developed bands. Our experimental results are interpreted in the framework of the Nilsson model. Precise Gallagher-Moszkowski splittings and Newby odd-even shifts extracted from the data are compared with theoretical calculations.

1988-06-01

490

Half Life of {sup 101}Mo and {sup 101}Tc {beta}{sup -}-decay  

Science.gov (United States)

In this work, the half-lives of the beta-unstable nuclei {sup 101}Mo and {sup 101}Tc were studied using neutron-irradiated samples of {sup 100}Mo to produce {sup 101}Mo which in its turn generates {sup 101}Tc by beta decay. The gamma activity of each sample was followed for 5 consecutive half-lives in steps of 5 minutes. A total of 22 sources were measured and checked for dead-time influence, and the half-lives were obtained by weighted average. The results are statistically incompatible with the tabulated values.

2009-06-03

491

Half Life of "1"0"1Mo and "1"0"1Tc #beta#"--decay  

International Nuclear Information System (INIS)

In this work, the half-lives of the beta-unstable nuclei "1"0"1Mo and "1"0"1Tc were studied using neutron-irradiated samples of "1"0"0Mo to produce "1"0"1Mo which in its turn generates "1"0"1Tc by beta decay. The gamma activity of each sample was followed for 5 consecutive half-lives in steps of 5 minutes. A total of 22 sources were measured and checked for dead-time influence, and the half-lives were obtained by weighted average. The results are statistically incompatible with the tabulated values.

2009-06-03

492

Forward Physics with the CMS experiment at the Large Hadron Collider  

CERN Document Server

multi-parton interactions and underlying event structure, $\\gamma$-mediated processes and luminosity determination, Monte Carlo tuning and even MSSM Higgs discovery in central exclusive production. In this article, the forward detector instrumentation around the CMS interaction point is described and the prospects for diffractive and forward physics using the CMS forward detectors are summarized. In addition, first observation of forward jets as well as early measurements of the forward energy flow in the pseudorapidity range $3.15

2010-01-01

493

A new method for sealing containers with liquid samples for radioactivity measurements  

International Nuclear Information System (INIS)

It is imperative to use a leak-proof container for counting liquid sample to prevent contamination of costly gamma detectors. A sealant that ensures no leak is reported. It is a vinyl adhesive sealant used for household purposes, marketed by Gloucester Co., Inc, Franklin, MA under the trade name of Phenoseal (translucent variety). This sealant was superior to other sealants studied because it cures quickly, peels off easily after counting, and contains no detectable radioactivity. This sealant has been thoroughly tested and successfully employed it in the routine analysis of environmental liquid samples. (author)

2002-08-01

494

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average ...

1992-11-12

495

Simultaneous Gas Chromatography-Mass Spectrometry Quantification of Endogenous [12C]- and Applied [13C]Indole-3yl-Acetic Acid Levels in Growing Maize Roots  

UK PubMed Central (United Kingdom)

The use of stable indole-3yl-acetic acid (IAA) labeled by 6 atoms of 13C allowed, after [13C]IAA treatment, simultaneous gas chromatography-mass spectrometry quantifications of...Full Text Available

1991-01-01

496

Large sample NAA facility at GRR-1 research reactor: Design and applications  

International Nuclear Information System (INIS)

Full text: A Large Sample Neutron Activation Analysis (LSNAA) facility is under development at GRR-1 research reactor, NCSR 'Demokritos'. The LSNAA facility design incorporates sample irradiation in the reactor's graphite thermal neutron column and subsequent measurement of the activity induced at a gamma spectroscopy system with gamma ray transmission measurement options included. Monte Carlo neutron and photon transport code MCNP-4C was used to model the facility. Appropriate correction factors accounting for neutron field perturbation during sample irradiation, high purity germanium detector efficiency for the volume source and gamma ray self-absorption within the sample itself were derived. The results of the computations were experimentally verified by activation foil measurements for a set of known materials and a range of sample sizes extending up to 10 ...

2003-06-09