The effect of phosphonate anion (PHOS) on the corrosion of ordinary steel in simulated cooling water has been studied using weight loss, polarization curves and electrochemical impedance spectroscopy measurements. PHOS was studied in the concentration range from 7.5x10^-^5 to 10^-^3M. The results obtained reveal that PHOS perform excellently as corrosion inhibitor for ordinary steel in simulated cooling water. The inhibition efficiency of PHOS was increased with increasing both its concentration and water circulation velocity. These two factors seem to promote the adsorption of phosphorus and oxygen ions on the metal surface, leading to the formation of a protective layer with a greater charge transfer resistance and lower permeability. The inhibition efficiency decreased slightly with tem...
The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.
Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.
Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from ...
The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.
Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).
The mechanism of the IndolPhos-Rh-catalyzed asymmetric hydrogenation of prochiral olefins has been investigated by means of X-ray crystal structure determination, kinetic measurements, high-pressure NMR spectroscopy, and DFT calculations. The mechanistic study indicates that the reaction follows an unsaturate/dihydride mechanism according to Michaelis-Menten kinetics. A large value of KM (KM=5.01+-0.16 M) is obtained, which indicates that the Rh-solvate complex is the catalyst resting state, which has been observed by high-pressure NMR spectroscopy. DFT calculations on the substrate-catalyst complexes, which are undetectable by experimental means, suggest that the major substrate-catalyst complex leads to the product. Such a mechanism is in accordance with previous studies on the mechanism...
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The ...
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The ...
In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe ...
The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are ...
Naturally occurring radioactive materials (NORM) in seven new type wall materials were surveyed. The radioactivity was determined with HPGe-#gamma# spectrometer. The red mud has the highest radioactivity concentration, followed by slag building blocks, fly-ash building blocks (bricks), gangue bricks and light weight board materials, gypsum blocks. Fly-ash and slag contain higher NORM, which contributes the major part of the radioactivity in new wall materials. (authors)
The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.
Natural radioactivity found in rocks and its evaluation been frequently used for studies of environmental geochemistry, particularly those of detection and control of pollutants and the consequent changes in environment after antropic interferences. In this work natural radioactivity in forty nine soil samples in the basin of Buquira river, at the Northeast region of Sao Paulo State, has been analysed and measured with a Ge-HP gamma ray spectrometer. A table with the most relevant results found in rocks is shown and discussed. (author)
A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built ...
The neutron-rich Fe isotopes from A=61 to 66 were studied through multinucleon transfer reactions by bombarding a "2"3"8U target with a 400 MeV "6"4Ni beam. Unambiguous identification of prompt #gamma# rays belonging to each nucleus was achieved using coincidence relationships with the ions detected in a high-acceptance magnetic spectrometer. The new data extend our knowledge of the level structure of Fe isotopes, which is discussed in terms of the systematics of the region and compared with large-scale shell-model calculations.
The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.
The level structure of the doubly-odd /sup 242/Am nucleus was investigated by means of thermal-neutron-capture gamma-ray and conversion electron spectroscopy. Pair, curved-crystal, and ..beta.. spectrometers were used. The data from these measurements, combined with previous direct reaction results, permit us to establish a detailed level scheme including six new well-developed bands. Our experimental results are interpreted in the framework of the Nilsson model. Precise Gallagher-Moszkowski splittings and Newby odd-even shifts extracted from the data are compared with theoretical calculations.
Prospective presentation is given for the experimental program of the KLOE-2 Collaboration, to be performed using the DA$\\Phi$NE $e^+e^-$ collider upgraded in luminosity. Data with the total luminosity of 25 fb$^{-1}$ are aimed to be collected in 3 years. Major modifications of the accelerator and the spectrometer are described. The KLOE-2 physics program contains: CKM unitarity and lepton universality tests, $\\gamma\\gamma$ physics, search for quantum decoherence and testing CPT conservation, low-energy QCD, rare kaon decays, physics of $\\eta$ and $\\eta^\\prime$, structure of low-mass scalars, contribution of vacuum polarization to $(g-2)_{\\mu}$, possible search for WIMP dark matter. In this paper only selected physics subjects are reported.
Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. Several signatures, ranging from the positron excess, as observed by HEAT, AMS-01 and PAMELA, the gamma ray excess, as observed by the EGRET spectrometer, the WMAP-haze, and constraints from antiprotons, as observed by CAPRICE, BESS and PAMELA, have been discussed in the literature. Unfortunately, the different signatures all lead to different WIMP masses, indicating that at least some of these interpretations are likely to be incorrect. Here we review them and discuss their relative merits and uncertainties. New x-ray data from ROSAT suggests non-negligible convection in our Galaxy, which leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in ...
High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gammaspectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise ...
{gamma}-ray excitation functions have been measured for the interaction of fast neutrons with {sup 48}Ti (neutron energy from 1 MeV to 250 MeV). The Los Alamos National Laboratory spallation neutron source, at the LANSCE/WNR facility, provided a ''white'' neutron beam which is produced by bombarding a natural W target with a pulsed proton beam. The prompt-reaction {gamma} rays were measured with the large-scale Compton-suppressed Ge spectrometer, GEANIE. Neutron energies were determined by the time-of-flight technique. Excitation functions were converted to partial {gamma}-ray cross sections, taking into account the dead-time correction, the target thickness, the detector efficiency, and neutron flux (monitored with an in-line fission chamber). The data analysis is presented here for neutron energies between 1 to 20 MeV. Partial {gamma}-ray cross ...
When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of research was opened. As the combination of a lead-moderated spectrometer and an electron beam type accelerator, the Kyoto University ...
The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for ...
The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and ...
The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a {sup 238}U target with a beam of {sup 70}Zn at an energy of E{sub lab}=460 MeV. Prompt {gamma} rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.
The neutron-rich Mn isotopes from A=59 to 63 have been studied through multi-nucleon transfer reactions by bombarding a "2"3"8U target with a beam of "7"0Zn at an energy of E_l_a_b=460 MeV. Prompt #gamma# rays measured by the CLARA array have been identified unambiguously for each nucleus, using coincidence relationships with ions detected in the high-acceptance magnetic spectrometer PRISMA. The new data extends the knowledge of the low-lying level structure of Mn isotopes, which is discussed in terms of the systematics of the region. Results are compared with large-scale shell-model calculations using different effective interactions and valence spaces.
An instrumental neutron activation technique of determining molybdenum in ores is based on measuring gamma-activity of the "9"9Mo isotope with the use of planar and coaxial semiconductor spectrometers. A lot consisting of 50 portions, 0.5 g each, is being irradiated for 10 hours by a flow of neutrons with the density of 10"1"2 n/cm"2xsec. On the lot being allowed to stay for 3-4 days, its activity is measured during 1-5 minutes. Monoethalons based upon phenol-formaldehyde resin are used as standards. The sensitivity of the technique is 10"-"4%, reproducibility error being not higher than 10%, efficiency up to 50 portions for a working shift.
Hard X-ray/gamma-ray spectrometers aboard two interplanetary spacecraft, Ulysses and Pioneer Venus Orbiter (PVO), and two near-Earth spacecraft, Yohkoh and Compton Gamma Ray Observatory (GRO/BATSE), are currently in operation. A unique set of circumstances have permitted the observation of the 15 November 1991 (2238 UT) flare by all the four instruments. This intense flare (GOES class X 1.5) was associated with the bright (3B) H-alpha flare located on the disk (S13, W19) in the active region 6919. At the time of the flare, the Ulysses and PVO spacecraft were located respectively 101[degree] and 52[degree] west of the Sun-Earth line. Thus the view angles for the PVO and Ulysses instruments were quite different from those of the near-Earth instruments on GRO and Yohkoh. The preliminary photon energy spectra observed by the four instruments at different times during the flare will be presented and their implications regarding ...
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...
In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. ...
A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is ...
The INTEGRAL/SPI spectrometer was designed to observe the sky in the energy band of 20 keV to 8 MeV. The specificity of instrument SPI rests on the excellent spectral resolution (2.3 keV with 1 MeV) of its detecting plan, composed of 19 cooled germanium crystals; covering an effective area of 508 cm{sup 2}. The use of a coded mask, located at 1.7 m above the detection plan ensures to it a resolving power of 2.5 degrees. The aim of this thesis, begun before the INTEGRAL launch, is made up of two parts. The first part relates to the analysis of the spectrometer calibration data. The objective was to measure and check the performances of the telescope, in particular to validate simulations of the INTEGRAL/SPI instrument response. This objective was successfully achieved. This analysis also highlights the presence of a significant instrumental background noise. Whereas, the second part concentrates on the data analysis of the Vela region ...
A new high-sensitivity wide-bandwidth 1.25-5.5 eV (225-1000 nm) spectrometer has been constructed to measure luminescence emission spectra of minerals that are of interest for optical dating. Spectra of emission resulting from 1.43 eV (IR) excitation after #gamma#-irradiation are reported for 13 cut rock feldspars and 20 feldspar separates. Also reported are phosphorescence spectra following #gamma#-irradiation, and after 1.4 eV excitation. The main differences between the infrared stimulated luminescence spectra and the phosphorescence is the almost complete absence of the violet, 3.1 eV, and yellow-green, 2.2 eV, bands in the phosphorescence, and the presence of a green emission band centred at 2.7 eV in the phosphorescence following #gamma#-irradiation (but absent in the phosphorescence following 1.4 eV excitation). The red, 1.7 eV, band is present in all the phosphorescence spectra but is not always ...
We have done analysis of elements in the Baltic sea sediment by using gamma spectrometry in neutron activation analysis Goal of the analysis is to determine the rate of morsel elements which is contained in the Baltic sea sediment. Sample of the Baltic sea Sediment (IAEA-SED-1), Standard of Reference Material (SRM) 1646 Estuarine Sediment and Standard Ce, Fe, Sc, and Co are put into vial of capsule rabbit, then irradiated together for 30 minutes in rabbit facility Multi Purpose Reactor at power of 25 MW and then cooled for one week. Next sample, standard, and SRM which have irradiated, each is cut for 30 minutes using gammaspectrometer. Result of analysis of rate of elements Ce, Fe, Sc and Co in the baltic sea sediment successively equal to 141.20 ppm, 5.91 %, 14.88 ppm, and 19.59 ppm. Result of analysis in SRM Estuarine sediment successively equal to 96.60 ppm, 3.21 %, 10.25 ppm, and 9.63 ppm. Result of this analysis if ...
This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in different countries. ...
Using a Q3D magnetic spectrometer the elastic and inelastic scattering of /sup 12/C on /sup 88/Sr and the neutron pick-up (/sup 12/C, /sup 13/C) has been studied. The spin alignment of the inelastically excited 2/sup +/ state of /sup 12/C (4.43 MeV) has been deduced from the line shapes broadened by the ..gamma..-decay in flight. Thus for each m-substate a full angular distribution was obtained. The m = 1 substate shows a shifted interference minimum, which is explained by the different strength of the Coulomb and nuclear amplitudes in the m-substates. The analysis of the data on elastic scattering, inelastic scattering, alignment and the neutron transfer can be described consistently with one choice of the optical model parameters.
The possibility to transform the future linear e"+e"-colliders into the #gamma#e and #gamma##gamma# colliders with approximately the same energies and luminosities was shown earlier. Their properties are compared from the point of view of possible physical investigations on them. 10 refs.; 1 tab.
Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and...Full Text Available
An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available
... comparative analysis is made of the sensitivity of two types of spectrometers: instruments employing coherent spontaneous radiation, and classical ...
Exploratory experiments of laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft were conducted. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. The corresponding mechanisms were discussed in detail. Results showed that the laser-welded seam had non-equilibrium solidified microstructures consisting of FeCr{sub 0.29}Ni{sub 0.16}C{sub 0.06} austenite solid solution dendrites as the dominant and some fine and dispersed Ni{sub 3}Al {gamma}' phase and Laves particles as well as little amount of MC short stick or particle-like carbides distributed in the interdendritic regions. The average microhardness of the welded seam was relatively uniform and lower than that of the base metal ...
Exploratory experiments of laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft were conducted. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. The corresponding mechanisms were discussed in detail. Results showed that the laser-welded seam had non-equilibrium solidified microstructures consisting of FeCr_0_._2_9Ni_0_._1_6C_0_._0_6 austenite solid solution dendrites as the dominant and some fine and dispersed Ni_3Al #gamma#' phase and Laves particles as well as little amount of MC short stick or particle-like carbides distributed in the interdendritic regions. The average microhardness of the welded seam was relatively uniform and lower than that of the base metal due to partial ...
The objective of the study is to measure the neutron cross sections for the "5"9 Co (n, 2n) "5"8 Co reaction around the 14 MeV energy region. Neutron activation cross section for almost all the nuclei, mostly in the medium energy region e.g., 7 to 20 MeV are reported in literature. Neutron cross section data around 14 MeV is of immense importance for the design of D + T fusion reactors. The accuracy of the cross section data at this energy region is a requirement for correct prediction of reactor parameters e.g., tritium breeding, nuclear heating, induced activity, etc. In order to perform the experiment, the Co-sample sandwiched in Ni foils was irradiated employing the J-25 Neutron Generator at the AERE, Savar, Dhaka. After irradiation, the counting was done by the activation technique using a high resolution Hp Ge gamma ray spectrometer. The gamma ray spectra was analyzed in a Canberra series-40 Multi-channel Analyzer. ...
Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of {gamma}-FeCr{sub 0.29}Ni{sub 0.16}C{sub 0.06} austenite solid solution ...
Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of #gamma#-FeCr_0_._2_9Ni_0_._1_6C_0_._0_6 austenite solid solution ...
Sodium is one of the most essential elements needed for metabolic processes amongst human beings. It is consumed in the form of sodium chloride but it is also present in edible plant leaves. Sodium is mostly analyzed by flame photometric method, a destructive and time consuming technique. Sodium has been determined in some green leave vegetables samples-palak, radish, khatta palak (ambat chuka), chaulai leaves, chauli bean covers and its seeds by instrumental neutron activation analysis. The method involves irradiation of samples with thermal neutrons from "2"4"1Am-Be source and counting "2"4Na activity (half life 15 hr) from the reaction "2"3Na(n,#gamma#) "2"4Na. Activity due to 1.37 MeV photopeak was counted with a NaI(Tl) crystal coupled to gamma ray spectrometer. Green leaves of the vegetables were thoroughly washed, dried at constant temperature and powdered. Bowen's Kale powder was used as standard for measuring ...
Decay processes of H{sub 2}{sup -} anions in {gamma}-rays-irradiated solid parahydrogen were studied by using ESR spectrometer. The following interesting results were obtained. First, the initial amount of ortho-H{sub 2}{sup -} anions in the {gamma}-irradiated solid parahydrogen was three times as large as those of para-H{sub 2}{sup -} anions. Second, the amount of para-H{sub 2}{sup -} anions decreases faster than that of ortho-H{sub 2}{sup -} anions upon storage of the irradiated samples at 4.2 K. Third, the decay rate of H{sub 2}{sup -} anions is accelerated by the addition of D{sub 2} molecules. Forth, H{sub 2}{sup -} anions at 2.2 K decay faster than at 4.2 K. According to the parity conservation rule in a homonuclear diatomic molecule, the energy of ortho-H{sub 2}{sup -} anions at the ground state is lower than that of para-H{sub 2}{sup -} anions, whereas that of ortho-H{sub 2} molecules is higher than that of ...
The physical layout of the Time-Of-Flight spectrometer at the new spallation source SINQ is presented. The concept shows up a hybrid-TOF combining a Fermi-chopper with a crystal monochromator. The demand of a versatile and flexible instrument for several applications is taken into account by the option of switching from time-focusing to monochromatic focusing mode such that the spectrometer can be optimised for both quasielastic and inelastic scattering applications. (author) 5 figs., 2 tabs., 16 refs.
A laser spectrometer for the ethylenediaminetetra-acetic acid (EDTA) titration of magnesium or calcium ions that is designed around a handheld laser pointer as the source and a photoresistor as the detector is developed. Findings show that the use of the spectrometer reduces the degree of uncertainty and error in one part of the EDTA titrations, however overall standard deviations depend on the skill of the student and their willingness to be careful and precise.
Complete text of publication follows. Baikal is an ancient unique lake. The sweet water of Baikal is crystal clean; it concentrates oxygen and contains scarce silicon. This feature is provoked very particular interest for scientists and poses some awkward questions concerning the preservation of Baikal's ecosystem. A profound investigation of fish otholiths, animal teeth, sponges, valves of mollusks and diatom algae provides chronological information, possibility to reconstruct the events proceeding in the environment based on variations of their chemical composition. Because these study objects are small-sized, and some of them are micron-size, application of the electron-probe microanalysis turns to be quite productive. The goal of this study is to disclose performance capabilities of this method while investigating the Baikal flora and fauna. Investigations were performed by devices JCXA-733 and JXA-8200 using the electron microscope and x-ray microprobe modes. Measurements of ...
The decays of Ta/sup 177/ and Lu/sup 177/ to levels in vestigated with beta spectrometers, NaI(Tl) gammaspectrometers, and fast coincidence and angular correlation techniques. Energy levels in Hf/sup 177/ were characterized according to their energy (kev), the Nilsson asymptotic quantum numbers (Nn/sub 2/ LAMBDA ), the total angular momentum and its component along the symmetry axis (I,K), and the parity ( pi ) as follows: 0STA5I4 7/2, 7/2-!; 112.97STA514 9/2, 7/ 2-!; 249.7STA5I4 11/2, 7/1-!; 32l.34STA624 9/2, 9/2+1; 447.9STA624 11/2, 585.8STA642 7/2, 3/2+1; 509.0STA5I2 5/2, 5/1-1; 605.5STA512 7/2, 5/2-!; 746.04STA633 7/2, 7/2+1; 848.2STA 633 9/2, 7/2+1; and 1058.38STA503 7/2, 7/2-!. The levels at 447.9, 488.8, and 585.8 kev are tentative. The spins and parities were uniquely determined by angular correlation and internal conversion data for the levels at 746.0 and 848.2 kev, asof the levels at 0, ...
It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).
We discuss the search of excited leptons and quarks with spin 1/2 at #gamma##gamma# and at #gamma#e colliders. We show that #gamma##gamma# colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l"*l#gamma# transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).
The authors study the processes {gamma}e {r{underscore}arrow} {gamma}e and {gamma}{gamma} {r{underscore}arrow} {gamma}{gamma}, in the context of the proposal for Weak Scale Quantum Gravity (WSQG) with large extra dimensions. With an ultraviolet cutoff M{sub S} {approximately} 1 TeV for the effective gravity theory, the cross sections obtained for these processes at the Next Linear Collider (NLC), with the e{gamma} an {gamma}{gamma} options, deviate from the predictions of the Standard Model significantly. The results suggest that, for typical proposed NLC energies and luminosities, the predictions of WSQG can be tested in the range 1 TeV {approx{underscore}lt} M{sub S} {approx{underscore}lt} 10 TeV, making e{gamma} an {gamma}{gamma} colliders important tools for probing WSQG.
We summarize the predictions of different models for total #gamma##gamma# cross-sections. The experimentally observed rise of #sigma#_#gamma#_#gamma# with s radical _#gamma#_#gamma#, faster than that for #sigma#_p_-_b_a_r_p, #sigma#_#gamma#_p is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of #sigma#_#gamma#_#gamma# with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range 300< s radical_#gamma#_#gamma# <500 GeV. We further show that the difference in model predictions for ...
Three possibilities to observe the Higgs-top interaction at future {gamma}{gamma}-colliders are discussed: (a) associated Higss production via the {gamma}{gamma}{yields}tanti tH reaction, (b) Higgs obliged radiative correction to the {gamma}{gamma}{yields}tanti t channel, (c) Higgs resonance production via {gamma}{gamma}{yields}H{yields}ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at {gamma}{gamma}-colliders. (orig.).
Three possibilities to observe the Higgs-top interaction at future #gamma##gamma#-colliders are discussed: a) associated Higss production via the #gamma##gamma##->#tanti tH reaction, b) Higgs obliged radiative correction to the #gamma##gamma##->#tanti t channel, c) Higgs resonance production via #gamma##gamma##->#H#->#ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at #gamma##gamma#-colliders. (orig.).
The first meeting on e{gamma}/{gamma}{gamma} colliders was held on September 28 and 29, 1993, at the National Laboratory for High Energy Physics. After general remarks were delivered, lectures were given on QED in intense laser field, photon linear collider, laser focusing, luminosity distribution in the e{gamma}/{gamma}{gamma} colliders, QCD correction for {gamma}{gamma}{yields}H, radiation correction for e{gamma}/{nu}W process, SUSY particle production at the e{gamma} and {gamma} gamma colliders, formation of e{sup *} in e{gamma} collision, and general remarks on the theory. Discussion was carried out on `Where are we going from here?` In this book, the gists of the lectures are collected. (K.I.).
M shell x-ray production cross sections in thick targets of Pb, Th and U by K x-rays of Rb, Nb and Mo respectively have been measured. As the incident K x-ray energies are above the L_3 edge but below L_2 edge energies of the respective target elements under reference, the M x-rays are produced not only due to direct interaction of incident photons with M shell electrons but also due to the shift of the L_3 subshell vacancies to the M shell. The experiment has been performed using a double reflection geometrical setup with a 1 Curie"2"4"1Am gamma ray source and a Si (Li) x-ray spectrometer. The measured values have been compared with those calculated using known values of M and L_3 subshell photoionisation cross sections and fluorescence yields etc., wherever possible. The component of the percentage contribution due to shift of L_3 subshell vacancies to M shell to the total M shell x-ray emission were evaluated and it is seen that the shift of ...
A considerable fraction of radioactivity entering the environment from different nuclear events is associated with particles. The impact of these events can only be fully assessed where there is some knowledge about the mobility of particle bound radionuclides entering the environment. The behavior of particulate radionuclides is dependent on several factors, including the physical, chemical and redox state of the environment, the characteristics of the particles (e.g., the chemical composition, crystallinity and particle size) and on the oxidative state of radionuclides contained in the particles. Six plutonium-containing particles stemming from Runit Island soil (Marshall Islands) were characterized using non-destructive analytical and microanalytical methods. By determining the activity of {sup 239,240}Pu and {sup 241}Am isotopes from their gamma peaks structural information related to Pu matrix was obtained, and the source term was revealed. Composition and ...
We describe the PBAR balloon-borne magnet spectrometer flown on August 13-14, 1987 to measure the abundance of cosmic ray antiprotons in the energy interval 100-1580 MeV at the top of the atmosphere. The limits first reported have been improved to an overall limit of anti p/p<2.0x10{sup -5} (85% CL). We summarize the overall design and performance of the PBAR spectrometer, which had the unique ability to establish the mass of each singly charged cosmic ray, as well as to reject spurious antimatter candidates caused by hard scatterings within the instrument. (orig.).
The driving system of a Moessbauer spectrometer is described. The system comprises a minivibrator, a digital generator of the reference velocity signal, and circuits for controlling the vibrator. The reference velocity signal is stored by the control computer in an intermediate storage. The feedback in the control circuits includes correction for nonlinearity of the driving facility. A Moessbauer spectrometer which is equipped with this driving system exhibits a velocity scale nonlinearity below 0.1%. The resonance line width for sodium nitroprusside is 0.27 #+-# 0.01 mm/s. (author). 6 figs., 8 refs.
The Gamma Physics (GaP) program of physical phenomena investigation is proposed on #gamma#p, #gamma#e and #gamma##gamma# colliders at TeV energies. The program contains specialized software (CompHEP system) created for automation of particle interaction processes calculations in the framework of various gauge models. Preliminary physical results are presented (heavy quark production, W, Z production, supersymmetry etc.), and further software development is suggested. (R.P.) 22 refs., 8 figs., 4 tabs.
instrument is shown in Figure 4-9 The incoming radiation is focused onto ...... An early rocket-borne ultraviolet spectrometer of the Ebert type by ...
A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.
Jan 22, 2011 ... dc.description.abstract, The progress in the development of a surface analysis tool based on the excitation of characteristic luminescence ...
The cross sections of neutral tensor mesons T=a_2, f, f', ... production in the exclusive #gamma##gamma##->#TT' or semiexclusive #gamma##gamma##->#TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV"2 are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future #gamma##gamma#-colliders is discussed too. (orig.).
Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).
We study the signals for composite vector leptoquarks in e"+e- colliders (CERN e"+e- collider LEP II, Next Linear Collider, and CERN Linear Collider) through their effects on the production of jet pairs, as well as their single and pair productions. We also analyze their production in #gamma#e and #gamma##gamma# collisions.
The angular ..gammagamma..-correlations for nuclei of Sr even-even isotopes with A=82, 84, 86, 88 were measured. Multipole structurs of ..gamma..-transtion series and th coefficients multipole mixing were determined.
The angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes with a=8 82, 84, 86, 88 were measured. Multipole structurs of #gamma#-transtion series and th coefficients multipole mixing were determined.
The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)
There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.
We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)
We discuss the search of excited leptons and quarks with spin 1/2 at {gamma}{gamma} and at {gamma}e colliders. We show that {gamma}{gamma} colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l{sup *}l{gamma} transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.
A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).
This paper describes a method for preparing the sample handling and inlet system of a mass spectrometer for analysis of a subsequent sample following analysis of a previous sample comprising the flushing of the system interior with supercritical CO{sub 2} and venting the interior. The method eliminates the effect of system ``memory`` on the subsequent analysis, especially following persistent samples such as xenon and krypton.
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))
We describe a new concept for a MEMS-based active spatial filter for astronomical spectroscopy. The goal of this device is to allow the use of a diffraction-limited spectrometer on a seeing limited observation at improved throughput over a comparable seeing-limited spectrometer, thus reducing the size and cost of the spectrometer by a factor proportional to r0/D (For the case of a 10 meter telescope this size reduction will be approximately a factor of 25 to 50). We use a fiber-based integral field unit (IFU) that incorporates an active MEMS mirror array to feed an astronomical spectrograph. A fast camera is used in parallel to sense speckle images at a spatial resolution of lambda/D and at a temporal frequency greater than that of atmospheric fluctuations. The MEMS mirror-array is used as an active shutter to feed speckle images above a preset intensity threshold to the spectrometer, thereby increasing ...
In this talk I briefly summarize different models for #sigma#_2_#gamma#"t"o"t (e"+e"-#->##gamma##gamma##->#hadrons) and contrast model predictions with the data. I will then discuss the capability of the future e"+e"- and #gamma##gamma# colliders to distinguish between various models and end with an outlook for future work.
A #gamma##gamma# collider would extend and complement the physics capability of a linear collider; e.g. it would be suitable for direct measurement of the partial decay width of a Higgs boson into two gamma quanta. This paper discusses choice of laser parameters, luminosity optimization, electron and laser parameters for a gamma- gamma collider as a second interaction region for the Next Linear Collider, laser path, and the lasers. It is concluded that a gamma- gamma collider is technically feasible; however it will require a significant investment in preparatory R ampersand D.
We investigate the chargino production process {gamma}{gamma} {yields} (W-tilde){sup +}(W-tilde){sup -} at high energy {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy {gamma} beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background {gamma}{gamma} {yields} W{sup +}W{sup -}. (author).
We investigate the chargino production process #gamma##gamma# #-># (W-tilde)"+(W-tilde)"- at high energy #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy #gamma# beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background #gamma##gamma# #-># W"+W"-. (author).
By generalizing the algebra satisfied by the ..gamma../sub 5/ matrix, it is possible to give an extension of ..gamma../sub 5/ to d dimensions. We discuss the connection of this scheme to others.
Due to legal restrictions, the German hard coal mining company Deutsche Steinkohle AG (DSK) is obliged to conduct a monitoring on surface changes (subsidence) caused by mining activity (e.g. topographic surface, groundwater, water, flora and fauna, soil). To fulfill legal demands and to do this effectively, process chains by use of Photogrammetry, Remote Sensing and Geo-Informationssystems (GIS) have been established. Photogrammetric methods are used to generate high resolution Digital Elevation Models (DEM) from which in combination with subsidence data geometrical changes at the topographic surface are deduced. The potential use of active sensors (Laser Scanning and Synthetic Aperture Radar Systems) to deduct DEM has been investigated. The applicability of SAR satellite data to detect and observe subsidence and resulting movements - point wise or with spatial extent - using differential SAR Interferometry (dInSAR) as well as persistent scatterer technology (here: the use of the ...
Radiochemical results ("2"3"4U, "2"3"8U, "2"2"6Ra and "2"2"8Ra activities; "2"3"4U/"2"3"8U, "2"2"8Ra/"2"2"6Ra and "2"2"6Ra/"2"3"8U activity ratios) are reported for 31 drinking water samples collected from 8 wells, 12 hot mineral springs, 5 cold springs, and 6 tap water samples. Activities of the Ra isotopes were measured by gamma spectrometry using a low background and high efficiency well type germanium detector. The U isotopes were counted in an alpha spectrometer. The results show that "2"3"8U activity varies between 4.46 and about 308 mBq l"-"1 in wells, 0.59 and 17.88 mBq l"-"1 in hot springs, 2.19 and 3.21 mBq l"-"1 in cold springs, and between 2.5 and 15.70 mBq l"-"1 in tap water samples. "2"3"4U/"2"3"8U activity ratio is generally higher than 1 which is the equilibrium activity ratio value in closed systems. It varies in the ranges 0.79-2.11 in wells, 0.97-7.39 in hot springs, 2.53-8.30 in cold springs, and 1.14-3.35 in tap water. ...
The object and the purpose of the present work was to develop, to assemble and to start running a new TOF (time of flight) mass spectrometer for imaging SNMS analytic which is optimized for the analysis of highly molecular secondary ions. The most important purpose was the characterization of the TOF mass spectrometer. The obtained mass spectra of indium, tantalum and silver clusters reflect the excellent properties of the TOF mass spectrometer for the detection of large clusters with good detection efficiency up to masses of 16000 amu. The possibility of the deflection of selected saturated atom and cluster peaks serves for further improvement of the detection efficiency for large molecules. The accessible mass resolution was determined to be of the order of m/{delta}m=1000 in the high mass region. Numerous measurements were carried out to characterize the useful yield of this spectrometer. For a best ...
Measurements using radioactive targets are important for the determination of key reaction path ways associated with the synthesis of the elements in nuclear astrophysics (sprocess), advanced fuel cycle initiative (transmutation of radioactive waste), and stockpile stewardship. High precision capture cross-section measurements are needed to interpret observations, predict elemental or isotopical ratios, and unobserved abundances. There are two new detector systems that are presently being commissioned at Los Alamos National Laboratory for very precise measurements of (n,{gamma}) and (n,f) cross-sections using small quantities of radioactive samples. DANCE (Detector for Advanced Neutron-Capture Experiments), a 4 {pi} gamma array made up of 160 BaF{sub 2} detectors, is designed to measure neutron capture cross-sections of unstable nuclei in the low-energy range (thermal to {approx}500 keV). The high granularity and high detection efficiency of ...
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
The International Linear Collider (ILC) and other proposed high energy e{sup +}e{sup -} machines aim to measure with unprecedented precision Standard Model quantities and new, not yet discovered phenomena. One of the main requirements for achieving this goal is a measurement of the incident beam energy with an uncertainty close to 10{sup -4}. This article presents the analysis of data from a prototype energy spectrometer commissioned in 2006-2007 in SLAC's End Station A beamline. The prototype was a 4-magnet chicane equipped with beam position monitors measuring small changes of the beam orbit through the chicane at different beam energies. A single bunch energy resolution close to 5 {center_dot} 10{sup -4} was measured, which is satisfactory for most scenarios. We also report on the operational experience with the chicane-based spectrometer and suggest ways of improving its performance.
The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...
Making use of a lead slowing-down spectrometer coupled to a 46 MeV electron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeV electron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)
Overtone absorption lines of "1"2C"1"6O_2 have been examined by using a tunable diode laser (TDL) spectrometer in the region around 12770cm"-"1. The spectrometer sources are commercially available double heterostructure InGaAlAs TDLs operating in the 'free-running' mode, which allowed the detection of the line positions within 0.01cm"-"1. The observed carbon dioxide absorption lines belong to the #nu#_1+5#nu#_3 ro-vibrational band with rotational quantum number J up to 48. The minimum absorbance detected by the spectrometer (#approx#5x10"-"6) permitted to observe the weakest lines having the absorption cross section of the order of #approx#1x10"-"2"7cm"2/molecule.
An apparatus for measuring the overall decontamination factors of first and second filters located in a plenum. The first filter separates the plenum's upstream and intermediate chambers. The second filter separates the plenum's intermediate and downstream chambers. The apparatus comprises an aerosol generator that generates a challenge aerosol. An upstream collector collects unfiltered aerosol which is piped to first and second dilution stages and then to a laser aerosol spectrometer. An intermediate collector collects challenge aerosol that penetrates the first filter. The filtered aerosol is piped to the first dilution stage, diluted, and then piped to the laser aerosol spectrometer which detects single particles. A downstream collector collects challenge aerosol that penetrates both filters. The twice-filtered aerosol is piped to the aerosol spectrometer. A pump and several valves control the movement ...
This chapter consists of some points including an introduction, the basic parts of mass spectroscope device, sample introduction into the inductively coupled plasma, pneumatic nebuliser, ultrasonic nebuliser, dry gas cloud system, laser ablation unit, inductively coupled plasma-ion source, extraction of ions from ion source, mass analysis, quad-polar mass spectrometer, dual assembly mass spectrometer, mass spectrometer by calculation of time of flight, ion interferences and the ability of resolution, ion counter, working conditions of inductively coupled plasma mass spectroscope device, efficiency of ion transportation in an inductively coupled plasma mass spectroscope device and applications of analysis using mass spectroscope of induced plasma including nuclear, industrial, geological, environmental and archaeological applications, measurement of isotopes ratio and applications in tracing crimes.
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
The collisions of high energy photons produced at an electron-positron collider provide a comprehensive laboratory for testing QCD, electroweak interactions, and extensions of the standard model. The luminosity and energy of the colliding photons produced by backscattering laser beams is expected to be comparable to that of the primary e"+e"- collisions. In this overview, we shall focus on tests of electroweak theory in photon-photon annihilation, particularly #gamma##gamma##->#W"+W"-, #gamma##gamma##->#Higgs bosons, and higher-order loop processes, such as #gamma##gamma##->##gamma##gamma#, Z#gamma# and ZZ. Since each photon can be resolved into a W"+W"- pair, high energy photon-photon collisions can also provide a remarkably background-free laboratory for studying WW collisions and annihilation. We also review high energy #gamma##gamma# tests of quantum chromodynamics, ...
The cross sections of neutral tensor mesons T=a{sub 2}, f, f', ... production in the exclusive {gamma}{gamma}{yields}TT' or semiexclusive {gamma}{gamma}{yields}TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV{sup 2} are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future {gamma}{gamma}-colliders is discussed too. (orig.).
We summarize the predictions of different models for total {gamma}{gamma} cross-sections. The experimentally observed rise of {sigma}{sub {gamma}}{sub {gamma}} with s radical {sub {gamma}}{sub {gamma}}, faster than that for {sigma}{sub p-barp}, {sigma}{sub {gamma}}{sub p} is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of {sigma}{sub {gamma}}{sub {gamma}} with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range ...
The results that can be expected by e#gamma# and #gamma##gamma# colliders in future are summarized. e#gamma# and #gamma##gamma# colliders have many fine possibilities, and are the economical selection for utilizing future e"+e"- colliders more effectively. e#gamma# and #gamma##gamma# colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e"+e"- collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e#gamma# and #gamma##gamma# colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e"+e"- accelerators. The production of #gamma#-beam is explained. As for the physics ...
We analyze spin correlations between top quark and anti-top quark produced at polarized e{sup +} e{sup -} and {gamma}{gamma} colliders. We consider a generic spin basis to find a strong spin correlation. Optimal spin decompositions for top quark pair are presented for e{sup +}e{sup -} and {gamma}{gamma} colliders. We show the cross- section in these bases and discuss the characteristics of results.
In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process {gamma}{gamma}{yields}HH are calculated. It is shown that the cross section is measurable at TeV {gamma}{gamma} colliders and is marginally sensitive to the triple-Higgs variation. (orig.).
In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process #gamma##gamma##->#HH are calculated. It is shown that the cross section is measurable at TeV #gamma##gamma# colliders and is marginally sensitive to the triple-Higgs variation. (orig.).
The complementarity of e{sup +}e{sup -} and {gamma}{gamma} colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios, we concentrate in detail on signatures for Large Extra Dimensions via the process {gamma}{gamma}{yields}WW.
The complementarity of e"+e"- and #gamma##gamma# colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios, we concentrate in detail on signatures for Large Extra Dimensions via the process #gamma##gamma##->#WW.
The complementarity of e{sup +}e{sub {minus}} and gamma-gamma colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios the authors concentrate in detail on signatures for Large Extra Dimensions via the process gamma-gamma --> WW.
Peroxisome proliferator activated receptor-{gamma} (PPAR{gamma}) regulates metabolic homeostasis and adipocyte differentiation, and it is activated by oxidized and nitrated fatty acids. Here we report the crystal structure of the PPAR{gamma} ligand binding domain bound to nitrated linoleic acid, a potent endogenous ligand of PPAR{gamma}. Structural and functional studies of receptor-ligand interactions reveal the molecular basis of PPAR{gamma} discrimination of various naturally occurring fatty acid derivatives.
The results that can be expected by e{gamma} and {gamma}{gamma} colliders in future are summarized. e{gamma} and {gamma}{gamma} colliders have many fine possibilities, and are the economical selection for utilizing future e{sup +}e{sup -} colliders more effectively. e{gamma} and {gamma}{gamma} colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e{sup +}e{sup -} collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e{gamma} and {gamma}{gamma} colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e{sup +}e{sup -} accelerators. The production of {gamma}-beam is ...
We investigate the sparticle production processes e{gamma} {yields} e tilde(Z tilde){sub 1} and {gamma}{gamma} {yields} (f tilde)(f tilde and bar) at high energy e{gamma} and {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e{gamma} colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e{gamma} {yields} (e tilde)(Z tilde){sub 1}. We show that the standard background processes e{gamma} {yields} {nu}W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e{gamma} {yields} (e ...
We investigate the sparticle production processes e#gamma# #-># e tilde(Z tilde)_1 and #gamma##gamma# #-># (f tilde)(f tilde and bar) at high energy e#gamma# and #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e#gamma# colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e#gamma# #-># (e tilde)(Z tilde)_1. We show that the standard background processes e#gamma# #-># #nu#W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e#gamma# #-># (e tilde)(Z tilde)_1 and ...
A curved crystal X-ray spectrographs of reflection type spherical geometry was required based on the Johann scheme. Due to their high efficiency and resolution, X-ray spectrographs of focusing spectrograph spatial resolution are suitable for detecting weak X-ray spectra in spectrometers for laser fusion research. Spherically bent mica crystal with a radius of curvature of 380 mm was used in the spectrometer. The Bragg angle of the crystal analyzer was 51 degree. The image plate was employed to obtain high spatial resolution and a narrow spectral band width, with an effective area of 30 mm x 80 mm. The designed optical path of the X-ray spectrometer beam was 980 mm long from the source to the crystal and the detector. The first experiment was carried out at the 20 J energy laser facility of Research Center of Laser Fusion, China Academy of Engineering Physics. X-ray spectra in an absolute intensity scale were obtained from ...
MIL-STD-129. N. 5/15/97. Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 ...
Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1 D. Notice 1. 12/15/99. 05/10/ 02 ...
This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The ...
This patent describes an expert overseer for the operation and real-time management of a mass spectrometer and associated laboratory equipment. The overseer is a computer-based expert diagnostic system implemented on a computer separate from the dedicated computer used to control the mass spectrometer and produce the analysis results. An interface links the overseer to components of the mass spectrometer, components of the laboratory support system, and the dedicated control computer. Periodically, the overseer polls these devices and as well as itself. These data are fed into an expert portion of the system for real-time evaluation. A knowledge base used for the evaluation includes both heuristic rules and precise operation parameters. The overseer also compares current readings to a long-term database to detect any developing trends using a combination of statistical and heuristic rules to evaluate the results. The ...
Feb 19, 2009 ... Standard Practice for Military Marking. MIL-STD-130. K. 1/15/00. Identification Marking of U.S. Military Property. MIL-STD-2073-1. D. Notice 1 ...
A new method of random data analysis has been developed with special implications for membrane noise. The integral spectrometer uses overlapping broad-band filters of simple design, whose bandwidth...Full Text Available
A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. We have constructed and tested several versions of the BCS. The results are described.
The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.
A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.
Secondary-electron emission (SEE) spectra have been obtained with the Scanning Probe Energy Loss Spectrometer at a tip-sample distance of only 50 nm. Such short working distances are required for the best theoretical spatial resolution (<10 nm). The SEE spectra of graphite, obtained as a function of tip bias voltage, are shown to correspond to unoccupied states in the electronic band structure. The SEE spectra of thin gold films demonstrate the capability of identifying (carbonaceous) surface contamination with this technique.
A conical Bragg-curve spectrometer (BCS) has been constructed. The outer case was a molded plastic cone. Printed circuit techniques were used to form an insert with inscribed equipotentials to approximate a 1/r/sup 2/ electric field shape. The charge and energy resolution were measured for elastically scattered beams of 206 MeV /sup 28/Si, 413 and 378 MeV /sup 56/Fe, and 670 MeV /sup 86/Kr ions. Performance of this detector, particularly its charge resolution, is discussed with respect to variation in solid angle.
This standard describes the procedure and equipment for in-place testing of HEPA filter systems by the single-particle, particle-size (SPPS) spectrometer method. This method provides the capability for evaluating the effectiveness (i.e., decontamination factor or DF) of systems consisting of one or more stages of HEPA filters against submicrometer aerosols in discrete particle-size ranges. It is particularly useful for testing of multi-stage HEPA filter installations and for testing of very large (50,000 cfm installed capacity) single-stage systems where it is desired to minimize the quantity of challenge aerosol required.
We operate a new NEC 250kV single-stage accelerator mass spectrometer (SSAMS) next to our established 5MV tandem. This permits good comparison of 14C-AMS and challenges SSAMS performance. Initial SSAMS ion-optical deficiencies have been addressed by shimming the injection magnet and 3permil 14C/13C measurement with background limited by sample chemistry is routine. Higher-precision analysis is also achievable. A problematic measurement interference remains, however. The small spectrometer was procured to add measurement capacity, and for experiments with positive ions, but is now the preferred instrument for both convenience and measurement quality.
Energy and angular double-differential cross-section (DDX) data of fragment production reactions by neutrons or protons are very scarce due to experimental difficulties of fragment detection. We adopted a Bragg curve spectrometer (BCS), which is a gridded-ionization chamber that can identify fragments on the basis of the Bragg peak value. We have been developing the BCS for neutron and proton-induced reactions applying the digital waveform analysis technique to obtain better ability of particle discrimination than the analog electronic circuit. (T. Tanaka)
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
We analyze the potential of the e{sup +}e{sup -} linear colliders, operating in the e{gamma} and {gamma}{gamma} modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2){sub L}(circle times)U(1){sub Y} chiral operators of order p{sup 4} that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e{gamma} and {gamma}{gamma} modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10{sup -2} at 90% C.L. Moreover, the information gathered in the e{gamma} mode can be used to reduce the ambiguities of the e{sup +}e{sup -} mode.
We analyze the potential of the e"+e"- linear colliders, operating in the e#gamma# and #gamma##gamma# modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2)_L(circle times)U(1)_Y chiral operators of order p"4 that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e#gamma# and #gamma##gamma# modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10"-"2 at 90% C.L. Moreover, the information gathered in the e#gamma# mode can be used to reduce the ambiguities of the e"+e"- mode.
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated ...
We study the production of three gauge bosons (W"+W"-Z"0 and W"+W"-#gamma#) at the next generation of linear e"+e"- colliders operating in the #gamma##gamma# mode. We analyze the total cross sections as well as several kinematical distributions of the final state particles. We find out that a linear e"+e"- machine operating in the #gamma##gamma# mode will produce 5--10 times more three-gauge-boson states compared to the standard e"+e"- mode at high energies.
An electroweak singlet scalar can couple to pairs of vector bosons through loop-induced dimension five operators. Compared to a Standard Model Higgs boson, the singlet decay widths in the diphotons and Z gamma channels are generically enhanced, while decays into massive final states like WW and ZZ are kinematically disfavored. The overall event rates into gammagamma and Z gamma can exceed the Standard Model expectations by orders of magnitude. Such a singlet may appear as a resonant signal in the gammagamma and Z gamma channels, even with a mass above the WW kinematic threshold.
Possible anomalous top-quark couplings induced by SU(2)xU(1) gauge-invariant dimension-6 effective operators were studied in the process of ttbar productions and decays at polarized #gamma##gamma# colliders. Two CP-violating asymmetries, a linear-polarization asymmetry and a circular-polarization asymmetry, were computed including both non-standard ttbar#gamma# and #gamma##gamma#H couplings. An optimal-observable analysis for the process #gamma##gamma##->#ttbar#->#l"#+-# was performed in order to estimate the precision for determination of all relevant non-standard couplings, including the anomalous tbW coupling.
Corrosion testings of model alloys, corresponding by chemical composition to simple and complex-alloyed #gamma#- and #gamma#'-phases of nickel heat-resistant alloys are conducted in sodium sulfate and chloride melts. It is ascertained that heat resistant nickel alloys containing over 50 % of hardening #gamma#'-phase, are subject to disastrous sulfide corrosion (SC). Resistance against SC alloys containing below 50 % of #gamma#'-phase is determined by the resistance of #gamma#-solid solution. 10 refs., 3 figs., 2 tabs.
The decay modes $\\jpsi\\ar\\gamma\\pi^0, \\gamma\\eta$ and $\\gamma\\etap$ are analyzed using a data sample of 58 million $\\jpsi$ decays collected with the BESII detector at BEPC. The branching fractions are determined to be: $Br(\\jpsi\\ar\\gamma\\pi^0)=(3.13^{+0.65}_{-0.44})\\times10^{-5}$, $Br(\\jpsi\\ar\\gamma\\eta)=(11.23\\pm0.89)\\times10^{-4}$, and $Br(\\jpsi\\ar\\gamma\\etap)=(5.55\\pm0.44)\\times10^{-3}$, where the errors are combined statistical and systematic errors. The ratio of partial widths $\\Gamma(\\jpsi\\ar\\gamma\\etap)/\\Gamma(\\jpsi\\ar\\gamma\\eta)$ is measured to be $4.94\\pm0.40$, and the singlet-octet pseudoscalar mixing angle of $\\eta-\\etap$ system is determined to be $\\theta_{P}=(-22.08\\pm0.81)^{\\circ}$.
We calculate the cross sections for the single production of doubly charged dileptons, both scalar and vector, at e"+e"-, e#gamma#, and #gamma##gamma# colliders at #sq root#s =500 GeV and 1 TeV. The e#gamma# mode is by far the most promising---dileptons whose coupling is as weak as #approx#10"-"4#alpha#_e_m can be observed, for masses virtually up to the kinematic limit. Dileptons of mass up to #sq root#s can also be seen in e"+e"- and #gamma##gamma# colliders, for couplings of order #alpha#_e_m. In all three colliders, most of the cross section comes from events in which the only particles detected are e"-e"- (or #mu#"-#mu#"- or #tau#"-#tau#"-), the decay products of the dilepton, yielding an unmistakable experimental signature.
The future e"+e"- linear colliders can also operate in the e#gamma# or #gamma##gamma# modes. In the context of the top-color assisted technicolor (TC2) model, we study the single charged top-pion production process #gamma##gamma# #-># tb-bar#PI#_t"-. The results show that the production rates can reach the level of tens fb with reasonable parameter values. So one can expect that enough signals could be produced in future high-energy linear collider experiments. Furthermore, the flavor-changing (FC) decay mode #PI#_t"- #-># bc-bar is the best channel to detect the charged top pion due to the clean standard model background. With a large number of events and the clean background, the charged top pion should be observable at future linear colliders operating in #gamma##gamma# mode at the TeV energy scale
We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in {gamma}{gamma}{yields}t t-bar {yields}lX/bX for various beam polarizations in order to study possible anomalous t t-bar {gamma}, tbW and {gamma}{gamma}H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and {gamma}{gamma} colliders from the viewpoint of the anomalous-top-quark-coupling determination.
We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in #gamma##gamma##->#t t-bar #->#lX/bX for various beam polarizations in order to study possible anomalous t t-bar #gamma#, tbW and #gamma##gamma#H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and #gamma##gamma# colliders from the viewpoint of the anomalous-top-quark-coupling determination.
CMSX-4 superalloy laser beam welds were investigated by transmission electron microscopy and atom probe field-ion microscopy (APFIM). The weld microstructure consisted of fine (10- to 50-nm) irregularly shaped {gamma}` precipitates (0.65 to 0.75 volume fraction) within the {gamma} matrix. APFIM compositions of the {gamma} and {gamma}` phases were found to be different from those in the base metal. Concentration profiles across the {gamma} and {gamma}` phases showed extensive variations of Cr, Co and Al concentrations as a function of distance within the {gamma} phase. Calculated lattice misfits near the {gamma}/{gamma}` interface in the welds are positive values compared to the negative values for base metal. (orig.).
We study the constraints on the anomalous coupling g_5"Z that can be obtained from the analysis of the reaction #gamma##gamma##->#W"+W"-Z at future linear e"+e"- colliders. We find out that a 0.5 (1) TeV e"+e"- collider operating in the #gamma##gamma# mode can probe values of g_5"Z of the order of 0.15 (4.5x10"-"2) for an integrated luminosity of 10 fb"-"1. This shows that the ability to search for this anomalous interaction of the #gamma##gamma# mode is better than the one of the usual e"+e"- mode, and it is similar to the ability of the e#gamma# mode.
There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.
Using $\\gamma \\gamma J/\\psi, J/\\psi \\ra e^+ e^-$ and $\\mu^+ \\mu^-$ events from a sample of $14.0\\times 10^6$ $\\psip$ decays collected with the BESII detector, the branching fractions for $\\psip\\ra \\pi^0\\J$, $\\eta\\J$, and $\\psi(2S)\\ar\\gamma\\chi_{c1},\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi$ are measured to be $B(\\psip\\ra \\pi^0\\J) = (1.43\\pm0.14\\pm0.13)\\times 10^{-3}$, $B(\\psip\\ra \\eta\\J) = (2.98\\pm0.09\\pm0.23)%$, $B(\\psi(2S)\\ar\\gamma\\chi_{c1}\\ar\\gamma\\gamma\\jpsi) = (2.81\\pm0.05\\pm 0.23)%$, and $B(\\psi(2S)\\ar\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi) = (1.62\\pm0.04\\pm 0.12)%$.
Interleukin 12 (IL-12) activates natural killer (NK) and T cells with the secondary synthesis and release of interferon-gamma (IFN-gamma) and other cytokines. IL-12-induced organ alterations are reported...Full Text Available
The phagocytic and killing abilities of heifer mammary gland macrophages (M phi) and neutrophils were evaluated after exposure to recombinant bovine interferon-gamma (rBoIFN-gamma) stimulation in vitro....Full Text Available
The radioactive decay of "2"0"3Bi is studied. A level scheme is proposed for "2"0"3Pb on the basis of #gamma#-ray and electron spectra and #gamma#-#gamma# coincidence measurements. The experimental data are compared with theoretical results obtained in a three quasiparticle approximation. (Auth.).
The CKM angle $\\gamma/\\phi_{3}$ had been measured by two B-factories, the PEPII collider for the BaBar experiment and the KEKB collider for the Belle experiments. The present paper reports recent progress in $\\gamma/\\phi_{3}$.
The natural biotic capacity of soils to degrade gamma-hexachlorocyclohexane (gamma-HCH, lindane) was estimated using an enrichment technique based on the ability of soil bacteria to develop on synthetic...Full Text Available
In Pseudomonas paucimobilis UT26, gamma-hexachlorocyclohexane (gamma-HCH) is converted by two steps of dehydrochlorination to a chemically unstable intermediate, 1,3,4,6-tetrachloro-1,4-cyclohexadiene...Full Text Available
The top-color assisted technicolor (TC2) mode predicts the existence of a pair of charged top-pions $\\pi^{\\pm}_t$. In this paper, we study the production of the charged top-pions pair $\\pi^{\\pm}_t$ at next generation $\\gamma\\gamma$ colliders. The results show that the production rates can reach the level of $10^2$ fb with reasonable parameter space. With a large number of events and the clean background, the charged top-pion should be observable at the $\\gamma\\gamma$ colliders. Therefore, our studies can help us to search for charged top-pion, and furthermore, to test the TC2 model.
We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).
We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).
Compton backscattering of laser photons near the interaction point of an e"+e"- or e"-e"- collider can be used to produce a #gamma#-#gamma# or #gamma#-e"- collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e"+e"- colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
Heavy quark production in $\\gamma\\gamma$ collisions is analyzed within the approach to hard collisions of photons recently proposed by the author. In this approach evaluating the cross section $\\sigma(\\gamma\\gamma\\to Q\\bar{Q})$ in the ``next-to-leading order of QCD'' requires the inclusion of direct photon contributions up to the order $\\alpha^2\\alpha_s^2$, whereas in the standard approach direct photon terms only up to the order $\\alpha^2\\alpha_s$ are taken into account. Phenomenological consequences of this difference are discussed.
We investigate the semihard production of neutral pseudoscalar and tensor mesons in high-energy [gamma][gamma] collisions (M=P=[pi][sup 0], [eta], [eta]' or M=T=a[sub 2], f[sub 2], f[sub 2]'). We deal with the exclusive [gamma][gamma][yields]MM' or semi-exclusive [gamma][gamma][yields]MX reactions (X is the hadron jet with not too large mass). The considered transfer momenta are small in comparison with the photon energies and they are large in comparison with the confinement scale. The amplitudes of these processes are determined by the odderon exchange, i.e. three-gluon exchange in the lowest order of perturbative QCD. The cross sections are calculated in this approximation. The possibility of measurements at LEP and at future [gamma][gamma] colliders is discussed. (orig.).
The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.
The production of pairs of doubly charged vector bileptons is studied at future #gamma##gamma# colliders. The unpolarized cross section for the #gamma##gamma##->#Y"-"-Y"+"+ subprocess is analytically calculated and convoluted to predict the number of events in the complete e"+e"-#->##gamma##gamma##->#Y"-"-Y"+"+ process. The gauge or nongauge character of the vector bilepton Y"#+-#"#+-# is discussed. It is found that, as a consequence of its spectacular signature, as it decays dominantly into two identical charged leptons, and also due to its charge contents, which significantly enhance the cross section, the detection of this class of particles with mass in the sub-TeV region can be at the reach of these colliders. The model-independent nature of our results is stressed.
The possibility of gamma-absorption identification of the analyzed substance is considered. the basic provisions of the proposed method are concentrated on the example of carbohydrates and hydrocarbons. The above method is tested experimentally on polyethylenes and polystyrene
Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and limitations should be ...
The coupled neutron-gamma cross section libraries BUGLE-80 and SAILOR are compared, with focus on gamma production and transport and its sensitivity to the thermal component of the neutron flux. In addition, the importance of the prompt versus delayed components of the gamma source is addressed. Although BUGLE-80 shows some discrepancies in the core region, the two libraries demonstrate similar capability in the vicinity of the pressure vessel and beyond. The delayed fission product gammas from the core have little impact on the local gamma fluxes beyond the pressure vessel. Although thermal neutron capture is the dominant component of the gamma source, there is little sensitivity of the gamma source to uncertainties in the thermal neutron cross sections, due to compensating effects which tend to keep the thermal neutron capture rate ...
We have developed a photon accumulated laser mass spectrometer that enables us to identify isomers of polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran. This system is comprised of a high temperature (230 deg. C) pulsed gas injector (PGI), multimirror multipath system (MMS), and the conventional time-of-flight mass spectrometer. The PGI induces the formation of a choked supersonic jet gas pulse that cools down to a temperature to restrain fragmentation and reduces vibrational and rotational thermal noises. The results suggest that the excited lifetime numbers and fragment dynamics of these species change completely with jet cooling of molecules. The MMS enhances the soft ionization efficiency (by a factor of 1000 over a single path system) through photon accumulation by extending the irradiation duration (to about 40 ns) and volume, and it further minimizes fragmentation by carefully controlling the laser intensity distribution ...
AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been ...
The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm iron design has been selected and analyzed. These low current densities are ...
The Alice experiment is one of the four main LHC (Large Hadron Collider) experiments. It is dedicated to the study of a new state of matter: the quark gluon plasma, where quarks and gluons are no longer confined within hadrons. In this document, the physics issues that led to the construction of Alice dimuon spectrometer, are described. Then, the research and development on the dimuon spectrometer is presented. The different absorbers are described and experimental tests used to determine their dimensions are presented. The dimuon trigger built using the RPC (Resistive Plate Chamber) streamer mode is then described along with the associated beam and cosmic tests and results. Finally, the tracking system is described in detail and more particularly all its electronics and the first station. The physics constraints on the expected performances of all these systems are clearly defined. (author)
The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment ...
State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method was developed to permit rapid, accurate ...
By means of neutron diffraction, using the standard polycrystalline sample of Al{sub 2}O{sub 3}, measurements on three (of four spectrometers) already installed in the front of horizontal channels of MARIA reactor have been performed. Basing on these experiments as well as on activation measurements carried out earlier, the fluxes of monoenergetic neutrons have been estimated. These experiments allowed to determine (for a given geometry and kind of monochromators chosen) the resolution efficiency of instruments and high order contamination in the reflected beam. With the help of polycrystalline vanadium and TbBr{sub 3} sample, the possibility of studies using the inelastic scattering process have been tested. (author) 7 refs, 15 figs, 7 tabs
A diffuse-reflectance capability for the Fourier transform infrared spectrometer at the Y-12 Plant Laboratory has been implemented. A sample cell with a 25 to 400/sup 0/C temperature-controlled sample stage and an ultrahigh-vacuum-to-atmospheric pressure gas-handling capability has been developed. Absorbance of light from the spectrometer beam, resulting from the beam being scattered from a powder sample, can be measured. This capability of detecting molecular species on and in powders is to be used to study chemisorption on actinide and rare-earth metals, alloys, and compounds. Cell design is described along with experiments demonstrating its performance in detecting moisture absorption on uranium oxide, moisture and carbon dioxide absorption on the lithium hydride/hydroxide system, and carbon dioxide absorption on potassium borohydride. 13 figures.
The Bragg Curve Spectrometer (BCS) is an ionization chamber long enough to stop particles of interest. Particles enter through the cathode window and leave an ionization track parallel to the electric field. The ionization electrons drift through a Frisch grid and are collected on an anode. The anode current, as a function of time, is proportional to the specific ionization along the track. The preamp output is split and used as input for two amplifiers, one with a long integration time constant for energy measurement, and one with a short time constant to pick off the maximum ionization or Bragg peak. The Bragg peak, which is proportional to the nuclear charge, is used for particle identification. Several versions of the BCS have been constructed and tested. Test results, detector characteristics and some design problems are discussed.
Analytical methods developed to sample and characterize ambient organic aerosols often face the trade-off between long sampling times and the loss of detailed information regarding specific chemical species present. In the work presented here, high-time resolution ambient measurements (3.5 minutes) are achieved by using the Photoionization Aerosol Mass Spectrometer (PIAMS) in conjunction with the mini-Versatile Aerosol Concentration Enrichment System (m-VACES). Aerosol sampling took place for one week at State of Delaware Air Quality Monitoring Site in Wilmington, Delaware in June 2006. The soft, universal ionization scheme of PIAMS allows for identification of various chemical compounds by a signature ion, often the molecular ion. Meteorological data was used to link some species, such as...
The authors have measured the relaxation time of hot electrons in short pulse laser-solid interactions using a picosecond time-resolved x-ray spectrometer and a time-integrated electron spectrometer. Employing laser intensities of 10{sup 17}, 10{sup 18}, and 10{sup 19} W/cm{sup 2}, they find increased laser coupling to hot electrons as the laser intensity becomes relativistic and thermalization of hot electrons at timescales on the order of 10 ps at all laser intensities. They propose a simple model based on collisional coupling and plasma expansion to describe the rapid relaxation of hot electrons. The agreement between the resulting K{sub {alpha}} time-history from this model with the experiments is best at highest laser intensity and less satisfactory at the two lower laser intensities.
The Formula Not Shown system of Formula Not Shown was first observed in auroral emissions by Meinel in 1950. Although the Formula Not Shown band system has been reinvestigated since this first spectral study, no laboratory spectrum of the (2,1) vibronic band has been obtained. We have recently built a continuous-wave cavity ringdown spectrometer, and as a first test of this spectrometer we observed the (2,1) band of Formula Not Shown in a positive column discharge cell. Many lines of the first positive band system of Formula Not Shown were also identified during the process of assigning this spectrum. The relative intensities of the Formula Not Shown and Formula Not Shown bands were found to change with discharge cell pressure, and so each spectral region was observed at two pressures to a...
The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.
A prism spectrometer has been developed to operate in the VUV wavelength range from 120 to 200 nm. It can be used as a pre- disperser in conjunction with a Fabry-Perot based gas refractometer. This instrument has also been used to measure the refractive index of the liquid radiator C/sub 6/F/sub 14/ in various spectral lines. This radiator is used in the RICH detectors of the DELPHI experiment and has been proposed for ALICE, and LHCb experiments. The spectral resolution of the system is improved as the wavelength decreases and the data are consistent with a wavelength accuracy about 0.4 nm at 140 nm. The results for the dispersion curve of the above liquid are presented. (17 refs).
The heavy Higgs bosons H,A of the minimal supersymmetric extension of the Standard Model can be produced as resonances in high-energy #gamma##gamma# colliders. Prospects of the search for these particles in bb-bar and neutralino-pair final states are studied in this report. Heavy Higgs bosons can be found with masses up to about 70-80% of the initial e"+e"- collider energy for moderate values of tan #beta#, i.e. in areas of the parameter space not accessible at other colliders.
Future #gamma##gamma# colliders allow the production of the heavy neutral MSSM Higgs bosons H and A as single resonances. The prospects of finding these particles in the bb-bar and the neutralino-pair final states have been analyzed. The H, A bosons can be discovered for medium values of tan #beta# with masses up to 70-80% of the initial e"#+-#e"- c.m. energy. This production mode thus covers parts of the supersymmetric parameter space that are not accessible at other colliders.
We study heavy physics effects on the Higgs production in #gamma##gamma# fusion using the effective Lagrangian approach. We find that the effects coming from new physics may enhance the standard model predictions for the number of events expected in the final states b-barb, WW, and ZZ up to one order of magnitude, whereas the corresponding number of events for the final state t-bart may be enhanced up to two orders of magnitude.
We investigate the scope of all relevant production modes of charged Higgs bosons in the MSSM, with mass larger than the one of the top quark, at future Linear Colliders operating in {gamma}{gamma} mode at the TeV energy scale. Final states with one or two H{sup {+-}} bosons are considered, as produced by both tree- and loop-level interactions. (orig.)
We investigate the scope of all relevant production modes of charged Higgs bosons in the MSSM, with mass larger than the one of the top quark, at future Linear Colliders operating in #gamma##gamma# mode at the TeV energy scale. Final states with one or two H"#+-# bosons are considered, as produced by both tree- and loop-level interactions. (orig.)
This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.
We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes {gamma}{gamma}{yields}4f and {gamma}{gamma}{yields}4f{gamma} in the standard model and extensions thereof by an effective {gamma}{gamma}H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes {gamma}{gamma}{yields}4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size ...
We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes #gamma##gamma##->#4f and #gamma##gamma##->#4f#gamma# in the standard model and extensions thereof by an effective #gamma##gamma#H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes #gamma##gamma##->#4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size of ...
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
Carbide reactions occurring in a precipitation-hardening gamma/gamma-prime Ni-Cr alloy during prolonged high-temperature aging are investigated experimentally. It is found that the decomposition of primary MC carbides, which is accompanied by the precipitation of M23C6 particles, may lead to void nucleation and growth. The effect of carbide transformations on the residual properties of the material at temperatures above the equicohesion temperature is observed at the late stages of aging only. 6 references.
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
Possible anomalous top-quark couplings induced by SU(2)xU(1) gauge-invariant dimension-6 effective operators were studied in the process of ttbar productions and decays at polarized {gamma}{gamma} colliders. Two CP-violating asymmetries, a linear-polarization asymmetry and a circular-polarization asymmetry, were computed including both non-standard ttbar{gamma} and {gamma}{gamma}H couplings. An optimal-observable analysis for the process {gamma}{gamma}{yields}ttbar{yields}l{sup {+-}} was performed in order to estimate the precision for determination of all relevant non-standard couplings, including the anomalous tbW coupling.
Physical processes in the region of laser conversion for the next Linear Colliders (NLC) are discussed. The main goal of this conversion is to obtain high-energy intense #gamma# beams for #gamma#e and #gamma##gamma# colliders. This conversion has important by-products: (i) one can observe here effect of nonlinear QED (in a strong external field)-production of e"+e"- pairs by a high-energy photon and emission of very high-energy photons by an electron; (ii) one can produce and observe here the invisible axion in colliding #gamma#_0e beams. The NQED effects also result in variation of the spectra of high-energy photons and an additional background. 12 refs., 12 figs., 1 tab.
The short review of complete tree level calculations for three particle final states production at the future e"+e"-, #gamma#e and #gamma##gamma# colliders is presented. The results obtained with the help of CompHEP system for total cross sections and other characteristics of processes in the energy range 0.1-2 TeV are summarized and their comparison with the results of different approaches is discussed. In particular we are interested in the processes of W, Z and H boson production. The reactions under consideration are especially interesting in connection with probing of new couplings, searching for new particle signals and as an important backgrounds to these experiments. The main subjects described are basic reactions rates (sections 2,3), Higgs production in #gamma#e collisions (section 4), the possibilities of testing some four vector bosons interaction vertices and Higgs-fermion coupling (section 5), the process of ...
We consider single production of leptoquarks (LQ's) at e"+e- and #gamma##gamma# colliders, for two values of the center-of-mass energy: #sq root#s =500 GeV and 1 TeV. We find that LQ's which couple within the first generation are observable for LQ masses almost up to the kinematic limit, both at e"+e- and #gamma##gamma# colliders, for an LQ coupling strength equal to #alpha#_e_m. The cross sections for single production of second- and third-generation LQ's at e"+e- colliders are too small to be observable. In #gamma##gamma# collisions, on the other hand, second-generation LQ's with masses much larger than #sq root#s /2 can be detected. However, third-generation LQ's can be seen at #gamma##gamma# colliders only for masses at most #approx# #sq root#s /2, making their observation more probable via the pair production mechanism.
1. Gamma globulin metabolism and distribution were studied employing rabbit gamma globulin (RGG)I(131) 24 times in 13 control rabbits. Similar studies were performed before and during the ananmestic response in 4 rabbits previously sensitized with a polyvalent pneumococcal vaccine. 2. During the ananmestic response, gamma-globulin levels increased from 1.0 to 6.0 gm/100 ml, and the gamma-globulin pool increased from 0.7 to 4.7 gm/kg. There was no change in the intravascular-extravascular partition of gamma globulin. 3. Gamma globulin degradation increased from 0.06 to 0.33 gm/kg/day during the 28 days of the immunization period while gamma globulin synthesis increased even further to average 0.47 gm/kg/day. Following the attainment of elevated gamma globulin levels the fractional rate of RGG-I(131) turnover increased ...
We consider the possibility of detecting a heavy Higgs boson (m_H>2m_Z) in proposed #gamma##gamma# colliders through the semileptonic mode #gamma##gamma##->#H#->#ZZ#->#q bar ql"+l-. We show that due to the nonmonochromatic nature of the photon beams produced by the laser-backscattering method, the resultant cross section for Higgs production is much smaller than the on-resonance cross section, and generally decreases with increasing collider energy. Although continuum ZZ production is expected to be negligible, we demonstrate the presence of, and calculate sizable backgrounds from, #gamma##gamma##->#l"+l-Z,q bar qZ, with Z#->#q bar q,l"+l-, respectively, and #gamma##gamma##->#t bar t#->#b bar bl"+l-#nu# bar #nu#. This channel may be used to detect a Higgs boson of mass m_H up to around 350 GeV at a 0.5 TeV e"+e- collider, assuming a nominal yearly luminosity of 10--20 fb"-"1.
We investigate the effect of anomalous gamma-W-W couplings in e-gamma --> nu W through the angular and energy spectrum of the secondary leptons. Within the narrow-width approximation, a semi-analytical study of the secondary lepton energy-angle double distribution is considered. Utility of observables derived from this is demonstrated by considering the anomalous coupling, delta-kappa-gamma. Results of our investigation for typical ILC machine considered at Ecm = 300-1000 GeV re-affirms potential of this collider as a precision machine.
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
The notion of intuitionistic fuzzy set was introduced by Atanassov as a generalization of the notion of fuzzy set. In this paper we apply this concept of Atanassov to ideals, prime ideals and semiprime ideals of gamma semigroups in order to obtain some characterization theorems. We also introduce the notion of Atanassov's intuitionistic fuzzy ideal extension in a gamma semigroup and investigate some of their important properties. A regular gamma semigroup has been characterized in terms of Atanasov's intutionistic fuzzy ideal. Characterization of prime ideal of a gamma semigroup has also been obtained in terms of Atanassov's intutionistic fuzzy ideal extension.
The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.
The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)
In embodiments, spectroscopic monitor monitors modulated light signals to detect low levels of contaminants and other compounds in the presence of background interference. The monitor uses a spectrometer that includes a transmissive modulator capable of causing different frequency ranges to move onto and off of the detector. The different ranges can include those with the desired signal and those selected to subtract background contributions from those with the desired signal. Embodiments of the system are particularly useful for monitoring metal concentrations in combustion effluent.
An irradiation head with sample holders is described and measurement geometry is reported. Measurements were made for optimizing the distance between the source and the sample and for optimizing the sample diameter. The optimal distance between the source and the sample does not depend on the collimator diameter. The sample diameter should not exceed 30 - 35 mm. Sensitivity and detection limits were determined for Zn, Pb and Br and calibration curves were plotted. (M.D.) 6 figs., 2 tabs., 4 refs.
A large double-focusing mass spectrometer was used to obtain new values for the masses of Sr/sup 86/, Sr/sup 88/, and Zr/sup 90/. Mass differences calculated from these values are found to be in better agreement with nuclear transmutation information than were previous mass spectroscopically derived values. (auth)
We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.
The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.
The lowest excited level in Ni-like ions, 3d{sup 9}4s {sup 3}D{sub 3}, decays only via a magnetic octupole (M3) decay. They present calculated values of transition wavelengths and rates for ions with 30 {le} Z {le} 100. They have observed this line in Xe{sup 26+}, using the Livermore EBIT-I electron beam ion trap and a microcalorimeter, as well as a high-resolution flat-field grating spectrometer.
Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)
Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)
Results are described of the study of the analytical applicability of a highly efficient ion source developed for a mass spectrometer. Its ionizer is in the form of a partially closed cavity with a small aperture for leading out ions, heated to a high temperature. The new ion source increases the sensitivity of the apparatus in operations with transuranium elements by almost two orders of magnitude. It is possible to perform isotopic analyses with a high salt content in the sample, and to study the characteristics of nuclear fuel, even without chemical separation of the sample elements.
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A /sup 241/Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer.
Fe, Mn, Ni, V, Ti and Mo were determined in aerosols from manual arc welding. Samples of welding aerosols were trapped on a Synpor 4 filter. The amount of determined elements in aerosols was detected using the method of radionuclide X-ray fluorescence analysis. A "2"4"1Am annular source was used as the source of excitation radiation and radiation was processed using a Si(Li) spectrometer. (E.S.).
The results of Sandia National Laboratories' participation in the NASA Planetary Definition and Design Program are summarized. Areas reported include the characterization of large area cadmium zinc telluride spectrometers and the application of simulation techniques to the prediction of device performance. Also investigated was the response of mercuric iodide devices in the region from 1 to 100 KeV. A literature study to determine the status or radiation damage measurements in room temperature semiconductor devices is also reported.
A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.
A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.
A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.
We have undertaken a study of ion mobility resolution in a miniature ion mobility spectrometer with a drift channel 1.7 mm in diameter and 35 mm in length. The device attained a maximum resolution of 14 in separating ions of NO, O{sub 2}, and methyl iodine. The ions were generated by pulses from a frequency-quadrupled Nd:YAG laser. Broadening due to Coulomb repulsion was modeled theoretically and shown experimentally to have a major effect on the resolution of the miniature device.
Characterization and optimization of electron-beam parameters are important aspects of optimizing free-electron laser (FEL) performance. The visible spontaneous emission ({lambda}{approximately}650 nm) from the 5-meter long undulator of the Boeing FEL experiment can be characterized in sufficient detail with a streak/spectrometer to deduce time-resolved electron-beam spatial position and profile, micropulse duration, and energy. 7 refs., 13 figs., 2 tabs.
A novel approach is presented to extract relevant parameters associated with the energy loss of ejectiles from nuclear reactions obtained by digitizing the signals of a Bragg curve spectrometer. New and more powerful computational paradigms allow a more thorough pulse-shape analysis. This is fulfilled using a back-propagation artificial neural network as a pattern identifier. The known problem of over-training is discussed.
A Software for the Neutron Scattering time-of-flight Spectrometer with 64 independent coded inputs is preset. It performs data acquirement and management. The work platform of the software is the Windows 98 and programmed with Visual Basic 6.0. It supports 64 x 1024 channel analyzer computer system. The friendly interface, convenient operation and high reliability are advantages of the Software
The absolute absorption of ozone in the midinfrared has been measured relative to 253.7-nm ultraviolet absorption to an accuracy of 1% using a Bruker Fourier transform spectrometer. These new results agree with previous measurements by diode laser measurements after the latter are corrected for more recent infrared calculations and ultraviolet cross sections. They also agree with a determination based on refractive index measurements in the infrared. 16 refs., 4 figs., 3 tabs.
The future e{sup +}e{sup -} linear colliders can also operate in the e{gamma} or {gamma}{gamma} modes. In the context of the top-color assisted technicolor (TC2) model, we study the single charged top-pion production process {gamma}{gamma} {yields} tb-bar{pi}{sub t}{sup -}. The results show that the production rates can reach the level of tens fb with reasonable parameter values. So one can expect that enough signals could be produced in future high-energy linear collider experiments. Furthermore, the flavor-changing (FC) decay mode {pi}{sub t}{sup -} {yields} bc-bar is the best channel to detect the charged top pion due to the clean standard model background. With a large number of events and the clean background, the charged top pion should be observable at future linear colliders operating in {gamma}{gamma} mode at the TeV energy scale.
The O({alpha}) electroweak radiative corrections to {gamma}{gamma}{yields}WW{yields}4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for {gamma}{gamma}{yields}4f+{gamma}. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer {gamma}{gamma} - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over ...
The O(#alpha#) electroweak radiative corrections to #gamma##gamma##->#WW#->#4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for #gamma##gamma##->#4f+#gamma#. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer #gamma##gamma# - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over ...
We study the constraints on the anomalous coupling {ital g}{sub 5}{sup {ital Z}} that can be obtained from the analysis of the reaction {gamma}{gamma}{r_arrow}{ital W}{sup +}{ital W}{sup {minus}}{ital Z} at future linear {ital e}{sup +}{ital e}{sup {minus}} colliders. We find out that a 0.5 (1) TeV {ital e}{sup +}{ital e}{sup {minus}} collider operating in the {gamma}{gamma} mode can probe values of {ital g}{sub 5}{sup {ital Z}} of the order of 0.15 (4.5{times}10{sup {minus}2}) for an integrated luminosity of 10 fb{sup {minus}1}. This shows that the ability to search for this anomalous interaction of the {gamma}{gamma} mode is better than the one of the usual {ital e}{sup +}{ital e}{sup {minus}} mode, and it is similar to the ability of the {ital e}{gamma} mode.
In this report, I surveyed physics potential of the {gamma}{gamma} option of a linear e{sup +}e{sup -} collider with the following questions in mind: What new discovery can be expected at a {gamma}{gamma} collider in addition to what will be learned at its 'parent' e{sup +}e{sup -} linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e{sup -} beams, we find that a {gamma}{gamma} collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e{sup -}e{sup -} system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a {gamma}{gamma} collider. CP property ...
In this report, I surveyed physics potential of the #gamma##gamma# option of a linear e"+e"- collider with the following questions in mind: What new discovery can be expected at a #gamma##gamma# collider in addition to what will be learned at its 'parent' e"+e"- linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e"- beams, we find that a #gamma##gamma# collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e"-e"- system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a #gamma##gamma# collider. CP property of the scalar sector can be explored in detail by ...
The energy and intensity of gamma rays as seen in thermal neutron capture are presented. Only those (n,..cap alpha..), E = thermal, reactions for which the residual nucleus mass number is greater than or equal to 45 are included. These correspond to evaluations published in Nuclear Data Sheets. The publication source data are contained in the Evaluated Nuclear Structure Data File (ENSDF). The data presented here do not involve any additional evaluation. Appendix I lists all the residual nuclides for which the data are included here. Appendix II gives a cumulated index to A-chain evaluations including the year of publication. The capture gamma ray data are given in two tables - the Table 1 is the list of all gamma rays seen in (n,..gamma..) reaction given in the order of increasing energy; the Table II lists the gamma rays according to the nuclide.
We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process {gamma}{gamma}{yields}tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future {gamma}{gamma} colliders for small values of tan {beta}. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)
We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process #gamma##gamma##->#tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future #gamma##gamma# colliders for small values of tan #beta#. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)
"1"0"1Mo is one of the key nuclides in diagnosing fission burn-up. However, it's difficult to measure its nuclear decay data due to its short half-life. Present study concerns in the measurements of #gamma#-ray emission probabilities, P_#gamma#, of "1"0"1Mo and "1"0"1Tc using the balance of scheme method and the entire process recording. The P_#gamma# of "1"0"1Mo by the entire process recording is about 5% lower than that by using the balance of scheme method. The P_#gamma# of "1"0"1Tc using the two methods agree each other very well. So, it seems the #gamma#-ray emission probabilities as well as measurement method still need study further for "1"0"1Mo. (authors)
The resonant scattering of bremsstrahlung #gamma#-rays by a SrCO_3 target has been studied for #gamma#-ray energies of 5-11 MeV. Six #gamma#-transitions of energies between 6-8 MeV, which indicate six resonant states in "8"8Sr, were observed. The relative intensities of the resonantly scattered #gamma#-rays at 125 and 150"0 were found to be compatible only with the assignment of spin 1 to the six states. Radiative widths of the resonant states were deduced. The possibility that these states are components of the giant M1 resonance in "8"8Sr is discussed. (orig.).
The {rvec n} + p {yields} d + {gamma} experiment under construction at LANSCE studies the weak interaction between neutrons and protons. The experiments will measure the directional dependence of the parity-violating {gamma}-ray asymmetry, A{sub {gamma}}, in the polarized cold neutron capture by para-hydrogen. The goal is to measure A{sub {gamma}} with uncertainty of 0.5 x 10{sup -8}, 10% of its predicted value. A{sub {gamma}} primarily isolates the {Delta}I = 1 component of the hadronic weak interaction and thus will determine the long-range weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. The experiment is carefully designed for the LANSCE pulsed spallation neutron source to achieve the proposed statistical precision and to control systematic errors. We discuss the experiment and its status.
One of the main challenges for a high energy {gamma}{gamma} collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).
One of the main challenges for a high energy #gamma##gamma# collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).
Higgs mediated flavor violating electromagnetic interactions, induced at the one-loop level by a nondiagonal Hf_if_j vertex, with f_i and f_j charged leptons or quarks, are studied within the context of a completely general effective Yukawa sector that comprises SU_L(2)xU_Y(1)-invariant operators of up to dimension-six. Exact formulae for the one-loop #gamma#f_if_j and #gamma##gamma#f_if_j couplings are presented and their related processes used to study the phenomena of Higgs mediated lepton flavor violation. The experimental limit on the #mu##->#e#gamma# decay is used to derive a bound on the branching ratio of the #mu##->#e#gamma##gamma# transition, which is 6 orders of magnitude stronger than the current experimental limit. Previous results on the #tau##->##mu##gamma# and #tau##->##mu##gamma##gamma# decays are reproduced. The possibility of ...
This talk summarizes recent progress in top quark physics studies for high energy linear electron-positron colliders as presented at the LCWS2000 Workshop at Fermilab. New results were presented for top pair production at threshold and in the continuum, as well as for top production at #gamma##gamma# colliders.
The present status of theoretical description of deep-inelastic lepton-nucleon as well as large angle Bhabha scattering with account for radiative corrections in the leading and next-to-leading approximations are reviewed. Also considered is a build-up principle and physical programme of the photon-photon colliders
We study double Higgs boson production at future linear colliders while paying special attention to the option of high-energy and high-luminosity photon beams. The main purpose is to examine the feasibility of e"+e"-, #gamma#e, and #gamma##gamma# colliders in order to establish bounds on the value of triple Higgs coupling, which could be crucial for understanding a spontaneous breaking mechanism. We consider mainly those cases of light and intermediate Higgs bosons, including an analysis of the electroweak backgrounds. The mass range M_H#approx#M_Z is discussed separately. It is shown that for a light Higgs boson the H"3 coupling can be visible, even at a future linear e"+e"- collider at 500 GeV. For an intermediate Higgs boson, a collider with TeV energies is suitable for investigations. We estimate the bounds on the anomalous H"3 coupling which can be experimentally established at future linear colliders. copyright 1996 The American Physical ...
I review the physic prospects for high energy photon photon colliders, emphasizing results presented at the LBL GammaGamma Collider Workshop. Advantages and difficulties are reported for studies of QCD, the electroweak gauge sector, supersymmetry, and electroweak symmetry breaking.
I review the physics prospects for high energy photon photon colliders, emphasizing results presented at the LBL GammaGamma Collider Workshop. Advantages and difficulties are reported for studies of QCD, the electroweak gauge sector, supersymmetry, and electroweak symmetry breaking. ((orig.)).
I review the physic prospects for high energy photon photon colliders, emphasizing results presented at the LBL GammaGamma Collider Workshop. Advantages and difficulties are reported for studies of QCD, the electroweak gauge sector, supersymmetry, and electroweak symmetry breaking.
I review the physics prospects for high energy photon photon colliders, emphasizing results presented at the LBL GammaGamma Collider Workshop. Advantages and difficulties are reported for studies of QCD, the electroweak gauge sector, supersymmetry, and electroweak symmetry breaking. ((orig.)).
We summarize some initial results in our investigation of the nuclear physics issues of gamma-ray lasers. We describe what is known thus far from existing experimental data and illustrate how theoretical models may be employed for systematic searches of candidate nuclei.
We summarize some initial results in our investigation of the nuclear physics issues of gamma-ray lasers. We describe what is known thus far from existing experimental data and illustrate how theoretical models may be employed for systematic searches of candidate nuclei.
Detailed level and decay schemes and the experimental reaction and decay data on which they are based are presented for nuclei with mass number A = 242; the experimental data are evaluated. Adopted values for level and ..gamma..-ray energies, ..gamma..-intensities, as well as other nuclear properties are given.
Detailed level and decay schemes and the experimental reaction and decay data on which they are based are presented for nuclei with mass number A = 242; the experimental data are evaluated. Adopted values for level and #gamma#-ray energies, #gamma#-intensities, as well as other nuclear properties are given.
Given an invariant gauge potential and a periodic scalar potential \\tilde{V} on a Riemannian manifold \\tilde{M} with a discrete symmetry group \\Gamma, consider a \\Gamma-periodic quantum Hamiltonian \\tilde{H}=-\\tilde{\\Delta}_{B}+\\tilde{V} where \\tilde{\\Delta}_{B} is the Bochner Laplacian. Both the gauge group and the symmetry group \\Gamma can be noncommutative, and the gauge field need not vanish. On the other hand, \\Gamma is supposed to be of type I. To any unitary representation \\Lambda of \\Gamma one relates a Hamiltonian H^{\\Lambda}=-\\Delta_{B}^{\\Lambda}+V on M=\\tilde{M}/\\Gamma where V is the projection of \\tilde{V} to M. We describe a construction of the Bloch decomposition of \\tilde{H} into a direct integral whose components are H^{\\Lambda}, with \\Lambda running over the dual space \\hat{\\Gamma}. The evolution ...
We present the complete next-to-leading order (NLO) QCD corrections to the top quark associated with $\\gamma$ production induced by model-independent $tq\\gamma$ and $tqg$ flavor-changing neutral-current (FCNC) couplings at hadron colliders, respectively. We also consider the mixing effects between the $tq\\gamma$ and $tqg$ FCNC couplings for this process. Our results show that, for the $tq\\gamma$ couplings, the NLO QCD corrections can enhance the total cross sections by about 50% and 40% at the Tevatron and LHC, respectively. Including the contributions from the $tq\\gamma$, $tqg$ FCNC couplings and their mixing effects, the NLO QCD corrections can enhance the total cross sections by about 50% for the $tu\\gamma$ and $tug$ FCNC couplings, and by about the 80% for the $tc\\gamma$ and $tcg$ FCNC couplings at the LHC, respectively. Moreover, ...
The NS together with a gamma ray sensor make up the Gamma- Ray and ... A simplified view of the interactions between incoming cosmic rays and the .... held in Huntsville, Alabama, at the U.S. Space and Rocket Center on January 2830. ...
Evidence is presented for a distinctive type of hippocampal synaptic modification [previously described for a molluscan gamma-aminobutyric acid (GABA) synapse after paired pre- and postsynaptic excitation]:...Full Text Available
In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite exposure,'' ...
We give a summary of the discussions in Working Group V of the CKM2010 workshop dealing with determinations of the angle gamma of the unitarity triangle of the Cabibbo-Kobayashi-Maskawa matrix from B-meson decays into charmed final states.
The motivation, feasibility and potential for two unconventional collider concepts - the Gamma-Gamma Collider and the Muon Collider - are described. The importance of the development of associated technologies such as high average power, high repetition rate lasers and ultrafast phase-space techniques are outlined.
The dielectrical properties of organosilicon sealants have been studied in the wide range of temperatures in the low and radio frequencies range. The effect of thermal treatment and #gamma#-irradiation on these properties is discussed.
Massive particle candidates for dark matter provide a potentially observable signature by virtue of their annihilations in the galactic halo at a known but model-dependent rate. Possible signatures are described, including cosmic ray antiproton and gamma-ray production. (orig.).
Neutron diffraction was used to monitor elastic strains during in situ tension testing of a directionally solidified (DS) superalloy at 900 deg. C. Changes in misfit and thermal expansion coefficients of individual phases were obtained. In the {gamma} phase, it is demonstrated that elastic strains saturate at 350 MPa, which is well below the yield strength of the alloy. This is interpreted as the onset of dislocation glide through less stressed vertical channels. The critical resolved shear stress (CRSS) of {gamma} is found to be 143 {+-} 11 MPa, in agreement with a calculated CRSS that is dominated by Orowan bowing of dislocations through nanoscale-wide {gamma} channels. This provides confirmation of Orowan bowing in plasticity/creep of the {gamma} phase. Implications of CRSS and misfit in a 'threshold stress' for creep and rafting are discussed. The CRSS of ...
Recent results using B_s -> J/Psi phi decays for measuring the CP violating phase, phi_s, and the decay width difference for the two mass eigenstates, Delta Gamma_s, are presented from the CDF and D0 experiments at the Fermilab Tevatron collider.
In nuclear fuel with a burn-up of 33 kg/t U and 52 kg/t U 15 transuranium nuclides /sup 237/Np to /sup 246/Cm have been determined by alpha and gamma spectroscopy after radiochemical separation.
Gamma interferon (IFN-γ) and the cellular responses induced by it are essential for controlling mycobacterial infections. Most patients bearing an IFN-γ receptor ligand-binding chain...Full Text Available
We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at {gamma}{gamma} colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R{sub p}-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)
We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at #gamma##gamma# colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R_p-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)
In view of the interest in the use of gamma irradiation to extend the storage life of pre-packaged foods a report is made on the effects of gamma radiation on the migration of Irganox 1076 and Irganox 1010, antioxidants present in food packaging plastics, into synthetic triglyceride fatty-food simulant HB307 and iso-octane. The extent of migration was assayed by h.p.l.c. techniques. Migration into HB307 and iso-octane decreased steadily as irradiation progressed suggesting that gamma irradiation of packaging materials helps to prevent the contamination of food by antioxidants in the packaging. (U.K.).
Some aspects of metrological provision of X-ray radiometric analyzers for mineral raw composition and gamma-gamma-logging equipment are considered. Standard samples (SS) based on the phenol-formaldehyde resin with the introduced quantities calculated of element compositions in the form of oxides and salts are described. Principles of metrological provision developed are used when carrying out state acceptance tests of X-ray radiometric analyzer RAL-M-102 ''Ehkran'' and gamma-gamma-logging equipmnt RSK-102. Economic benefit from introduction of an SS set is #approx# 60-100 thousand roubles per year.
We consider the impact of a 4th generation on Higgs to $\\gamma\\gamma$ and $WW,ZZ$ signals and demonstrate that the Tevatron and LHC have essentially eliminated the possibility of a 4th generation if the Higgs is SM-like and has mass below 200 GeV. We also show that the absence of enhanced Higgs signals in current data sets in the $\\gamma\\gamma$ and $WW,ZZ$ final states can strongly constrain (almost eliminate) the possibility of a 4th generation in two-Higgs-doublet models of type II (in the MSSM).
We have studied the signals for a heavy Higgs boson in the processes {gamma}{gamma}{yields}WWWW, and {gamma}{gamma}{yields}WWZZ at a photon linear collider. The results are based on the first complete tree-level calculation for these reactions. We show that, with a forward ``spectator`` W tag, and a central ``spectator`` W veto to suppress backgrounds from transverse W, Z production, the invariant mass spectrum of central WW, ZZ pairs is sensitive to Higgs bosons with a mass up to 1 TeV in a 2-TeV linear collider. ((orig.)).
The heavy Higgs bosons H,A of the minimal supersymmetric extension of the Standard Model can be produced as resonances in high-energy {gamma}{gamma} colliders. Prospects of the search for these particles in bb-bar and neutralino-pair final states are studied in this report. Heavy Higgs bosons can be found with masses up to about 70-80% of the initial e{sup +}e{sup -} collider energy for moderate values of tan {beta}, i.e. in areas of the parameter space not accessible at other colliders.
We study heavy physics effects on the Higgs production in {gamma}{gamma} fusion using the effective Lagrangian approach. We find that the effects coming from new physics may enhance the standard model predictions for the number of events expected in the final states {bar {ital b}}{ital b}, {ital WW}, and {ital ZZ} up to one order of magnitude, whereas the corresponding number of events for the final state {bar {ital t}}{ital t} may be enhanced up to two orders of magnitude. {copyright} {ital 1996 American Institute of Physics.}
We study heavy physics effects on the Higgs production in #gamma##gamma# fusion using the effective Lagrangian approach. We find that the effects coming from new physics may enhance the standard model predictions for the number of events expected in the final states bar bb, WW, and ZZ up to one order of magnitude, whereas the corresponding number of events for the final state bar tt may be enhanced up to two orders of magnitude. copyright 1996 American Institute of Physics.
The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).
Most general tbW couplings were investigated in the process {gamma}{gamma} {yields} tt-bar {yields} l{sup {+-}}X for unpolarized photon beams. The double angular and energy distribution of the lepton was calculated and an optimal-observable analysis on it was carried out for the SM tt-bar production mechanism. It was also shown that the leptonic angular distribution is insensitive to non-standard tbW vertex. That means that observation of non-standard effects indicates existence of some new physics in the production part.
Most general tbW couplings were investigated in the process #gamma##gamma# #-># tt-bar #-># l"#+-#X for unpolarized photon beams. The double angular and energy distribution of the lepton was calculated and an optimal-observable analysis on it was carried out for the SM tt-bar production mechanism. It was also shown that the leptonic angular distribution is insensitive to non-standard tbW vertex. That means that observation of non-standard effects indicates existence of some new physics in the production part.
Samples of vynil-benzene and vinyl acetate were irradiated with gamma rays from a sup(60)Co source. Viscosity analysis performed by using the method of Stokes showed an increase in the viscosity of the materials up to the total solidification for increased doses of gamma rays. This result characterized the formation of macromolecules of two thermal plastics, the poly (vinyl-benzene) and the poly (vinyl acetate). (author).
The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.
An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).
Based on BACODINE network notification the Whipple Observatory gamma-ray telescope has been used to search for the delayed TeV counterpart to BATSE-detected gamma-ray bursts. In the fast slew mode, any point in the sky can be reached within two minutes of the burst notification. The search strategy, necessary because of the uncertainty in burst position and limited FOV of the camera, is described.
The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.
The beams in electron linear colliders can be converted to nearly monochromatic photon beams by means of Compton backscattering of laser photons. The electron beams must then be diverted from the interaction point by some means, the best of which seems to be a plasma lens. This paper describes the constraints on the plasma lens in this application and shows how the ablation of solid hydrogen pellets might be able to produce plasmas to satisfy these constraints. ((orig.)).
It seems to be very natural that whole program for constructing and exploring of linear colliders (including photon colliders as the substantial part) should be divided by stages according to the increasing beam energy. We discuss the main stages of this program and the set of physical problems for each stage photon colliders. ((orig.))
It seems to be very natural that whole program for constructing and exploring of linear colliders (including photon colliders as the substantial part) should be divided by stages according to the increasing beam energy. We discuss the main stages of this program and the set of physical problems for each stage photon colliders. ((orig.)).
We discuss the main stages of a physical program for photon linear colliders. We consider the problems in electroweak theory, hadron physics, QCD, and nonlinear QED, as well as new particles and interactions, etc. The discussed stages constitute the parts of an entire ambitious program for linear colliders. ((orig.)).
E-beam and gamma products from the radiolysis of aqueous solutions of (+-)-metoprolol tartrate, saturated in nitrogen, are analyzed by HPLC with on-line mass and UV detectors. The structures of 10 radiolytic products common to e-beam and gamma irradiations are elucidated by comparing their fragmentation pattern to that of (+-)-metoprolol. Two of the radiolytic products are also metabolites. Different routes for the formation of the radiolytic products are proposed.
The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.
This paper presents the results obtained in the gamma scanning of two fuel pins from the bent subassembly of the fast breeder test reactor (FBTR) using a segmented gamma scanning system employing segment correlation developed for the assay of glove box solid waste. In addition to the actinide profiles, the paper also discusses the fission products and clad activation product profiles and tries to correlate the experimental values of the latter with computed values. (author). 4 refs., 1 fig., 1 tab.
The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).
This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.
Effects of gamma irradiation on the physiological effectiveness of Korean medicinal herbs were investigated. The physiological effectiveness including antioxidant and anticomplement function, nitrite scavenging and electron donating ability of Korean medicinal herbs by gamma irradiation at 10 kGy did not differ from that of the nonirradiated control.
Effects of gamma irradiation on hygienic quality and extraction yields in twenty-one kinds of Korean medicinal herbs were investigated. Gamma irradiation at 5-10 kGy inactivated contaminating microorganisms. The total extraction yield in fifteen kinds of the investigated medicinal herbs increased by 5-25% by a dose of 10 kGy. (author)
The effect of irradiation using several doses of X- and #gamma#-rays (10, 20, 40, 60, 80 and 100 kGy), upon total phenolic compounds contained in the leaves of Maytenus aquifolium Martius (Celastraceae) 'espinheira santa', was investigated. The content of phenolic compounds (measured by the Folin-Denis spectrophotometric method) was unaffected by X- or #gamma#-ray irradiation, at any dose. (author)
The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting #gamma#-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision.
The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting {gamma}-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision. ((orig.)).
The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting #gamma#-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision. ((orig.)).
In Pseudomonas paucimobilis UT26, gamma-hexachlorocyclohexane (gamma-HCH) is converted to 2,5-dichloro-2,5-cyclohexadiene-1,4-diol (2,5-DDOL), which is then metabolized to 2,5-dichlorohydroquinone....Full Text Available
The availability of rice, gamma -irradiated up to 4.6 x 10/sup 4/ and 3.5 x 10/sup 5/r for koji was studied. The enzyme activities of koji of the steamed samples were stronger than the unirradiated rice in amylase and protease. The sensory test on the once-steamed irradiated rice was almost the same as the twice-steamed unirradiated rice. (OID)
In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.
For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO{sub 4}. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm{sup -2}. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g{sup -1}, respectively. The better electrochemical property should be ascribed to the better crystallized ...
For the first time, rheological phase method, a simple and effective route, is applied to synthesize novel cathode material LiCoPO4. X-ray diffraction spectrometer (XRD), X-ray photoelectron spectrometer (XPS), transmission electron microscope (TEM) and electrochemical impedance spectroscopy (EIS) are taken to investigate this material, respectively. XRD figure shows that the rheological sample is better crystallized than the solid-state one. XPS result of the rheological sample exhibits that the valence of Co is 2+. TEM images show that better dispersed particles with smaller size can be formed by rheological method comparing to the solid-state route. Charge-discharge test is carried out in the range of 3.0-5.0 V at 0.2 mA cm-2. The initial discharge capacity for rheological phase and solid-state powder is 71.5 and 30.9 mAh g-1, respectively. The better electrochemical property should be ascribed to the better crystallized rheological phase ...
Non-destructive methods of diagnosis for detecting cable degradation by aging are being studied recently for improvement of electric wires and cables. This study examines degradation behaviors of cable sheath and insulation by combined accelerated aging tests applying thermal and radiation stresses simultaneously using a typical low voltage cable. According to experiments, elongation of cross-linked polyethylene insulation deteriorated at a faster rate than PVC sheath did under low doses below 50 Gy/h. Therefore, measurements using a time domain dielectric spectrometer (TDS) were carried out for the purpose of developing a method of degradation diagnosis of insulation. It was found that values of tan#delta# measured at very low frequencies below 0.1 Hz increase in pace with degradation of insulation reflecting the level of degradation more effectively than those measured at frequencies around the commercial frequency. In order to consider causes of the increases of ...
Neutron elastic and inelastic scattering cross sections of _2_3_8U and _2_3_2Th have been measured at the University of Lowell for states below 1.8 MeV. A time-of-flight (TOF) spectrometer was used. The disc-shaped scatterer was oriented to optimize energy resolutions for 200-to-500-keV neutrons. Neutrons were obtained via the _7Li(p,n)_7Be reaction. Targets were prepared by in-situ evaporation of Li onto a Ta backing. During the evaporation, the target thickness was monitored using a 5-m-flight-path TOF spectrometer; a typical target had a neutron thickness from 8 to 10 keV for Esub(p) = 2.25.MeV. Spectra were analyzed using the unfolding code TINA; standard peak shapes were obtained from codes LAGUE and LAPA. Results obtained will be presented.
The recent development of matrix-assisted UV laser desorption (LD) mass spectrometry has made possible the ionization and detection of extremely large molecules (with molecular weights exceeding 100,000 Daltons). This technique has generated enormous interest in the biological community for the direct examination of large peptides and oligonucleotides. Although this matrix-assisted ionization method has been developed and used almost exclusively with time-of-flight (TOF) mass spectrometers, research is currently in progress to demonstrate this technique with trapped ion mass spectrometers, such as Fourier transform ion cyclotron resonance mass spectrometry (FTMS). The potential capabilities of FTMS for wide mass range, high resolution measurement, and ion trapping experiments suggest that this instrumental technique should be useful for the detailed structural characterization of large ions generated by the matrix-assisted technique. We have ...
High-throughput synthesis and screening methods have been developed for the discovery of highly active catalysts for the control of emissions from stationary and mobile sources. Low temperature CO oxidation, CO methanation, NOx abatement and the destruction of Volatile Organic Compounds (VOCs) will be discussed. The discovery libraries for primary screening consisted of both 11x11 and 16x16 catalyst arrays on 3 inch and 4 inch quartz wafers, respectively. Catalysts were prepared by robotic liquid dispensing techniques and screened for catalytic activity in Symyx's Scanning Mass Spectrometer. The screening protocols encompassed mixed metal oxides, perovskites and supported base and noble metals. Active hits were further optimized in focus libraries using shallower compositional gradients. The ScanMS is a fast serial screening tool that uses flat wafer catalyst surfaces, local laser heating, a scanning/sniffing nozzle and a quadrupolar mass ...
The symmetric noncoplanar (e,2e) cross sections (momentum profiles) of H_2 and D_2 for the transitions to the 2p#sigma#_u and 2s#sigma#_g excited ion states have been measured, relative to the ground-state ion transition, using a high-sensitivity multichannel momentum-dispersive electron momentum spectrometer (EMS) at an impact energy of 1200 eV. Newly calculated plane-wave impulse approximation (PWIA) cross sections, based on a full-configuration-interaction H_2 wave function, are compared to the experimental results. These calculations are in better agreement with the experimental results for the transition to the 2s#sigma#_g ion state than the earlier theoretical work of Liu and Smith, Jr. [Phys. Rev. A 31, 3003 (1985)] which has been found to be in error. Nevertheless, significant discrepancies between the relative experimental and theoretical cross sections are observed for the transitions to excited ion states, suggesting a failure of the PWIA description of ...
We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of [Delta][epsilon] = 1.3 [mu]eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T[sub m] (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T[sub m]. Quasielastic broadening in the spectrum at Q = 0.082 A[sup -1] is observed only above 210degC, which is 75degC higher than the T[sub m]. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 [mu]eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).
We have recently developed a high resolution quasielastic neutron scattering spectrometer LAM-80ET by applying mica crystals as analyzers and achieved a resolution of #DELTA##epsilon# = 1.3 #mu#eV using the 002 reflection. Single chain dynamics of polyethylene has been investigated below and above the melting temperature T_m (=135degC) to show the feasibility of the mica 002 reflection as the analyzer. It was found that elastic scattering intensity from polyethylene decreases very steeply around the T_m. Quasielastic broadening in the spectrum at Q = 0.082 A"-"1 is observed only above 210degC, which is 75degC higher than the T_m. From the analysis of the spectra by a curve-fitting method, the width of the quasielastic component was evaluated to be 1.8 #mu#eV at 250degC and the activation energy of the width to be 34 kJ/mol. (author).
An energy analyzer has been constructed and operated in UHV for the purpose of analyzing the energy of neutral atoms scattered from solid surfaces. The analyzer consists of a LiF single crystal located at an angle close to the normal to the sample crystal so that the diffraction pattern obtained by scanning the LiF crystal yields the energy of the scattered atoms. Two designs which have been used are described. The temperature of both sample and analyzer crystal is near 20 K and once cleaned they can be maintained in the state of initial preparation for many weeks. The sample was a (001) Cu surface in this case. Such an energy analyzer can only be used, in most cases, for He atom scattering although Ne atoms could be used if the scattered intensities were adequate. The detector developed in this study is able to detect about 2 x 10"5 atoms/s. The resolution of the spectrometer depends on the incident energy of the atom and is about 1 meV at an incident energy of 23 ...
Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative ...
The BESS detector is a new type of balloon-borne spectrometer which utilizes various technologies recently developed for collider experiments. The principal scientific objectives include a measurement of cosmic-ray antiproton spectrum, search for anti-nuclei in cosmic radiation, and precise measurements of cosmic-ray primaries. A thin superconducting solenoidal coil produces a uniform magnetic field of 1 T. Cylindrical drift chambers are located inside and outside the coil and perform continuous tracking. The momentum resolution is 0.5% at 1 GeV/c. i.e., the maximum detectable rigidity is 200 GV. Scintillation counter hodoscopes, placed above and below the solenoid, provide timing and dE/dx measurements and trigger generation. The timing resolution is 80 ps/counter. This cylindrical configuration achieves a large geometrical acceptance of 0.35 m{sup 2} sr which is essential to detect rare cosmic-ray particles. In order to cope with high trigger rate and large data ...
DescriptionChamber studies have shown that biogenic organic compounds, including isoprene, are capable of producing secondary organic aerosol in significant quantities. This is surprising as isoprene and its photo-oxidation products have relatively high vapour pressures. However, it is very important as isoprene has the largest global emissions flux of any biogenic hydrocarbon, most of which is in the tropics. Despite this, secondary organic aerosol has been poorly studied in tropical regions with only [continued...
The penetration depth and concentration distribution for vanadium ions with low energy implanted into the dry peanut seeds is determined by scanning electron microscope and X-ray energy dispersion spectrometer. The results show that the depth-concentration distribution is a Gaussian distribution with a long tail and the maximum penetration depth is about 13.6 #mu#m for V"+ with 200 keV in cotyledon of the peanut. The experimental result of the implanted V"+ range in the peanut seeds is compared with the calculating value of the TRIM95
The "8"8Y decay has been studied with the aim to discover emission of monohromatic positrons (MP). The "8"8Sr(d,2N) reaction was used for production of "8"8Y (#beta#"+, Tsub(1/2)=106.6 days) nuclides. The prismatic beta spectrometer has been used to measure spectra of electrons and positrons. No MPs have been found. The resulting upper bound for their emission rate turned out to be lower than theoretically expected one.
The CP violating processes J/psi-->K_S K_S and psi(2S)-->K_S K_S are searched for using samples of 58 million J/psi and 14 million psi(2S) events collected with the Beijing Spectrometer at the Beijing Electron Positron Collider. No signal is observed, and upper limits on the decay branching ratios are determined to be BR(J/psi-->K_S K_S) K_S K_S) < 4.6x10^{-6} at the 95% confidence level.
When in resonance, Raman scattering exhibits strong enhancement ranging from four to six orders of magnitude. This physical phenomenon has been applied to remote sensing of the Earth`s atmosphere. With a 16 inch Cassegrain telescope and spectrometer/ CCD-detector system, 70-150 ppm-m of SO{sub 2} in the atmosphere has been detected at a distance of 0.5 kilometer. This system can be used to detect/monitor chemical effluence in the atmosphere by their unique Raman fingerprints. Experimental result together with detailed resonance Raman and atmospheric laser propagation effects will be discussed.
The refractive index of novel organosilica (nano/micro)material is determined using two methods. The first method is based on analysis of optical extinction efficiency of organosilica beads versus wavelength, which is obtained by a standard laboratory spectrometer. The second method relies on the measurable trapping potential of these beads in the focused light beam (laser tweezers). Polystyrene beads were used to test these methods, and the determined dispersion curves of refractive index values have been found accurate. The refractive index of organosilica beads has been determined to range from 1.60-1.51 over the wavelength range of 300-1100 nm.
Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).
The RSS collaboration has measured the spin structure functions of the proton and the deuteron at Jefferson Lab using the Hall C HMS spectrometer, a polarized electron beam and a polarized solid target. The asymmetries A and A were measured in the region of the nucleon resonances (0.82 GeV < W < 1.98 GeV) at an average four momentum transfer of Q2 = 1.3 GeV2. The extracted spin structure functions and their kinematic dependence will make a significant contribution in the study of higher-twist effects and polarized duality tests. A description of the experiment and the latest findings of the analysis will be presented.
#pi#"#+-# and K"#+-# cumulative production in pA #-># #pi#"#+-#+x and pA #-># K"#+-#+x reactions at 10.14 GeV proton beam energy on nuclei (Be-Ta) was invesigated. Measurements were conducted using FAS-1 focusing hadron spectrometer. Invariant cross sections of #pi#"#+-# and K"#+-# cumulative production, values of ratio of this cross sections, dependences of production cross sections for pions and kaons on cumulative number and mass number of nucleus target, as well as on transverse momentum are measured. Difference of cumulative meson spectra occurring in different nuclei fragmentation is discussed in terms of flucton model. 17 refs.; 14 figs.
The processes psi'-->p pbar pi^0 and psi'-->p pbar eta are studied using a sample of 14 million psi' decays collected with the Beijing Spectrometer at the Beijing Electron-Positron Collider. The branching fraction of psi'-->p pbar pi^0 is measured with improved precision as (13.2\\pm 1.0\\pm 1.5)\\times 10^{-5}, and psi'-->p pbar eta is observed for the first time with a branching fraction of (5.8\\pm 1.1\\pm 0.7)\\times 10^{-5}, where the first errors are statistical and the second ones are systematic.
The first measurement of the pn{yields}d{omega} total cross-section has been achieved at mean excess energies Q{approx}28 and 57 MeV by using a deuterium cluster-jet target. The momentum of the fast deuteron was measured in the ANKE spectrometer at COSY-Juelich and that of the slow ''spectator'' proton (p{sub sp}) from the pd{yields}p{sub sp}d{omega} reaction in a silicon telescope placed close to the target. The cross-sections lie above those measured for pp{yields}pp{omega} but seem to be below theoretical predictions. (orig.)
An accelerator experiment was performed using a low-energy antiproton beam to measure antiproton detection efficiency of BESS, a balloon-borne spectrometer with a superconducting solenoid. Measured efficiencies showed good agreement with calculated ones derived from the BESS Monte Carlo simulation based on GEANT/GHEISHA. With detailed verification of the BESS simulation, the relative systematic error of detection efficiency derived from the BESS simulation has been determined to be {+-}5%, compared with the previous estimation of {+-}15% which was the dominant uncertainty for measurements of cosmic-ray antiproton flux.
The BESS-Polar spectrometer had its first successful balloon flight over Antarctica in December 2004. During the 8.5-day long-duration flight, almost 0.9 billion events were recorded and 1,520 antiprotons were detected in the energy range 0.1-4.2 GeV. In this paper, we report the antiproton spectrum obtained, discuss the origin of cosmic-ray antiprotons, and use antiprotons to probe the effect of charge sign dependent drift in the solar modulation.
The mass and energy distributions for low-energy p- and alpha-particle induced fission of "1"8"7","1"8"8Ir and "1"9"5Au and "3He-induced fission of sufficiently heated "1"8"8Ir and "1"9"4Au have been measured with use of fast spectrometer of complementary fragments. From Au to Ir, the shape of the mass distributions undergoes substantial changes related to specific dependence of the saddle shell corrections on A and Z fissioning nuclei. The results are compared with theoretical predictions.
We have undertaken a program which measures the photoelectron spectra of negative-ion beams. This experiment has afforded us direct information about these ions and the corresponding neutral radicals. Several ions and numerous radicals are believed to be crucial intermediates in combustion processes and flame chemistry. We have fabricated a spectrometer which directly measures electron affinities (EA). Knowledge of the EA and gas-phase acidity of a radical has enabled us to deduce several radical heats of formation and bond strengths.
The branching ratio of J/psi-->K_S K_L is measured with improved precision to be B(J/psi-->K_S K_L) = (1.82\\pm 0.04\\pm 0.13)\\times 10^{-4}. using J/psi data collected with the Beijing Spectrometer (BESII) at the Beijing Electron-Positron Collider. This result is used to test the perturbative QCD ``12%'' rule between psi(2S) and J/psi decays and to investigate the relative phase between the three-gluon and one-photon annihilation amplitudes in J/psi decays.
The failure took place on a welded elbow pipe which exhibited a catastrophic transverse rupture. The failure was located on the welding HAZ region, parallel to the welding path. Branching cracks were detected at the edge of the rupture area. Deposits of corrosion products were also spotted. The optical microscope analysis showed the presence of transgranular failures which were related to the stress corrosion cracking (SCC) and were predominantly caused by the welding residual stress. The significant difference in hardness between the welded area and the pipe confirmed the findings. Moreover, the failure was also caused by the low Mo content in the stainless steel pipe which was detected by means of spark emission spectrometer. (orig.)
The hot uniform aluminium plasma was produced by irradiating thin aluminium dotted foil smoothly with the 9th 0.53 ?m laser on Shenguang II laser facility. The emitted spectrum was measured from the front and tangential direction of the target with two crystal spectrometers, and the quantitative spectrum from the front of the target was obtained. The state of laser- produced plasma was simulated with the radiation hydrodynamics code MULTI-1D, and the emitted spectrum was calculated with the spectrum code of Collision-Radiation model under the simulated plasma state. The experimental spectrum accords with the simulated one. (authors)
Neutron deficient nuclei with mass numbers A {approx} 90 and 40 {<=} Z {<=} 44 have been studied making use of the Osiris and Nordball spectrometers. The high spin states of these nuclei and their electromagnetic decay properties are compared to shell model calculations based on the core {sup 88}Sr and using different parametrizations of the residual interaction. The dependence of the mean square deviations of experimental and theoretical level energies, branching ratios, and transition probabilities on the neutron numbers N = 46-50 and the validity of seniority as a good quantum number are discussed. (orig.).
A novel way to extract relevant parameters associated with the outgoing ions from nuclear reactions, obtained by digitizing the signals provided by a Bragg curve spectrometer (BCS) is presented. This allowed the implementation of a more thorough pulse-shape analysis. Due to the complexity of this task, it was required to take advantage of new and more powerful computational paradigms. This was fulfilled using a back-propagation artificial neural network (ANN) as a pattern identifier. Over training of ANNs is a common problem during the training stage. In the performance of the ANN there is a compromise between its size and the size of the training set. Here, this effect will be illustrated in relation to the problem of Bragg Curve (BC) identification. (Author)
The validity of the Big Bang theory is evaluated. The basis of the Big Band theory and the supercluster observations of Tully, which conflict with the Big Band theory, are discussed. Various explanations for the existence of supercluster observations are proposed. The cosmic background explorer (COBE) is being utilized to detect energetic processes. The COBE contains a far IR absolute spectrometer, a differential microwave radiometer, and a diffuse IR background experiment. The hypothesis of the evolution of the universe of Hannes Alfven, which emphasizes the importance of electricity and magnetism, is presented and research illustrating the importance of electric currents and magnetic fields in space is examined.
We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.
The authors have performed a preliminary design for a persistent GHz NMR magnet at 23.5 T and 1.8 K operating conditions. In this paper the authors shall address the issues of realistic conductor selection, the coil design, the magnetic and mechanical analysis of the coil, and the required field uniformity. In addition, they shall describe the GHz magnet cryostat with a practical 1.8 K J-T refrigerator system. Finally vibration isolation system and field shield design and its associated field harmonics will be analyzed.
We compute the limiting distribution, as n approaches infinity, of the number of cycles of length between gamma n and delta n in a permutation of [n] chosen uniformly at random, for constants gamma, delta such that 1/(k+1) <= gamma < delta <= 1/k for some integer k. This distribution is supported on {0, 1, ... k} and has 0th, 1st, ..., kth moments equal to those of a Poisson distribution with parameter log (delta/gamma). For more general choices of gamma, delta we show that such a limiting distribution exists, which can be given explicitly in terms of certain integrals over intersections of hypercubes with half-spaces; these integrals are analytically intractable but a recurrence specifying them can be given. The results herein provide a basis of comparison for similar statistics on restricted classes of permutations.
The authors describe a new method which makes it possible to determine the radial distribution of the diffuse component of galactic gamma rays outside the solar circle. They use the observation that a good correlation exists between gamma-ray intensities and total column densities of the local interstellar gas and that the fractional column density of H_2<0.1 HI outside the solar circle. Thus the gamma-ray intensities are shown to be proportional to N(HI). The authors use the kinematics of the HI to determine the distances from which various fractions of the emission originate in the second and third galactic quadrants. Preliminary results of our analysis show that a significant flux of gamma rays originates from distances as large as 18 kpc from the galactic centre. (Auth.).
Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.
Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.
Compton backscattering of laser photons near the interaction point of an e{sup +}e{sup -} or e{sup -}e{sup -} collider can be used to produce a {gamma}-{gamma} or {gamma}-e{sup -} collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e{sup +}e{sup -} colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab ...
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper ...
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
An easy and simple method for gamma assay of large multi gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following tow simple well known facts: Large and small samples of the same homogenous material have identical activities; the self attenuation of gamma line decreases as its energy increases. The method was successfully applied to NORM (Naturally Occurring Radioactive Material) large samples. This method doesn't require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed. (author)
{gamma}-Butyrolactone-based electrolytes have been used as the operating electrolytes for aluminum electrolytic capacitors. The chemical stability of these electrolytes at elevated temperatures has been examined by monitoring the decrease in their electrolytic conductivities. The deteriorated electrolytes were analyzed by gas and liquid chromatography and the conductivity decrease was directly correlated with the loss of acid components. In quaternary ammonium hydrogen maleate/{gamma}-butyrolactone electrolytes, the maleate anion decomposed by decarboxylation resulting in a complex polymer containing polyester and polyacrylate structures. Quaternary ammonium benzoate/{gamma}-butyrolactone electrolytes decomposed by SN2 reactions giving alkyl benzoates and trialkylamines. The deterioration of the carboxylate salt/{gamma}-butyrolactone electrolytes was accelerated by electrolysis. (orig.)
A complete code based on the finite element method (FEM) is used to study the attenuation of gamma rays, of source energy 9 MeV, in simple homogeneous lead and water systems. The results are compared, in tables and graphs, with those produced by a Monte Carlo method of solution. In the comparison, particular attention is paid to the annihilation gamma rays generated by the pair production process, to energy deposition, and to the leakage spectra. A model, multilayer, slab shield, having a fission neutron source impinging on the left-hand face, is also solved by the FEM code, using data from a coupled neutron/gamma ray cross section library. The resulting neutron and gamma ray flux distributions, and the leakage spectra, are shown graphically. (author).
Methods currently being used or developed for the elemental analysis of materials are chemical analysis, non-destructive inspection and calorimetry. The chemical analysis, which removes high-level radioactive elements through chemical treatments and then performs the quantitative analysis using the ICP-MS(Inductively Coupled Plasma - Mass Spectrometer) or the ID-MS(Isotope Dilution Mass Spectrometer), is recognized the most accurate. However, it requires a long, complex pre-treatment process in which a mass spectrometer could be contaminated. To solve this problem, a new method, which can be performed with high-level radioactivity and at high temperature, was desired. Such a method should also have the same accuracy as the chemical analysis, with a less possibility for instruments to be contaminated. In addition, as interests in the environment and the life quality are increased, a detailed analysis on the environmental ...
Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the analysis of CH{sub 2}, ...
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma ...
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma ...
The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from ...
The thiazolidinedione (TZD) or glitazone class of peroxisome proliferator-activated-#gamma# (PPAR-#gamma#) ligands not only induce adipocyte differentiation and increase insulin sensitivity, but also exert growth inhibitory effects on several carcinoma cell lines in vitro as well as in vivo. In the current study the in vitro effect of four PPAR-#gamma# agonists (ciglitazone, pioglitazone, troglitazone, rosiglitazone) on the cell growth of seven human neuroblastoma cell lines (Kelly, LAN-1, LAN-5, LS, IMR-32, SK-N-SH, SH-SY5Y) was investigated. Growth rates were assessed by a colorimetric XTT-based assay kit. Expression of PPAR-#gamma# protein was examined by immunohistochemistry and Western blot analysis. All glitazones inhibited in vitro growth and viability of the human neuroblastoma cell lines in a dose-dependent manner showing considerable effects only at high concentrations (10 #mu#M and 100 ...
We examine the virtual effects of Kaluza-Klein (KK) states on Higgs physics in universal extra dimension models. We study the partial widths {Lambda}{sub h{yields}gg}, {Lambda}{sub h{yields}{gamma}{gamma}}, and {Lambda}{sub h{yields}{gamma}Z}, which are relevant for Higgs production and detection in future collider experiments. These interactions occur at one loop in the Standard Model, as do the KK contributions. We find that the deviations induced by the KK exchanges can be significant; for one extra dimension, the gg {yields} h production rate is increased by 10% - 85% for the mass of the first KK state in the range 500 {approx}> m{sub 1} {approx}> 1500 GeV, a region untested by current direct search and precision measurement constraints. The h {yields} {gamma}{gamma} decay width is decreased by {approx}< 20% in the same mass range. For two or more universal extra dimensions the results are cutoff ...
2009 has been an extraordinary year for gamma-ray pulsar astronomy and 2010 promises to be equally good. Not only have we registered an extraordinary increase in the number of pulsars detected in gamma rays, but we have also witnessed the birth of new sub-families: first of all, the radio-quiet gamma pulsars and later an ever growing number of millisecond pulsars, a real surprise. We started with a sample of 7 gamma-ray emitting neutron stars (6 radio pulsars and Geminga) and now the Fermi-LAT harvest encompasses 24 "Geminga-like" new gamma-ray pulsars, a dozen millisecond pulsars and about thirty radio pulsars. Moreover, radio searches targeted to LAT unidentified sources yielded 18 new radio millisecond pulsars, several of which have been already detected also in gamma rays. Thus, currently the family of gamma-ray emitting neutron stars ...
In the decoupling limit M_A_"0"2>>M_Z"2, the heavy CP-even, CP-odd, and charged Higgs boson masses are nearly degenerate, sin(#beta#-#alpha#) approaches 1, and the lightest CP-even Higgs boson almost displays the same properties as the standard model Higgs boson. But the top and bottom squark sectors can change this pattern through radiative corrections. We find that there are parameter regions at small and moderate tan #beta# in the minimal supersymmetry standard model under experimental constraints of (g-2)_#mu#, b#->#s#gamma#, and lower bounds of Higgs boson and sparticle masses, where sin"2(#beta#-#alpha#) is damped (say below 0.8), which has a significant effect on Higgs couplings g_h_"0_V_V(V=W"#+-#,Z"0) and g_h_"0_#gamma#_#gamma#. We discuss its impact on the lightest CP-even Higgs boson production at #gamma##gamma# colliders.
A future e"-e"+ (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an #gamma#-#gamma# (gamma-gamma) or a e"--#gamma# collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e"-e"+ configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also address concerns ...
A future e{sup -}-e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup -}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup -}-e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5-15 kW from the laser which is beyond the current state of the art. In this paper, we address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. We also address ...
A future e{sup {minus}}e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup {minus}}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup {minus}}e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser ...
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma ...
The functional interaction between the peroxisome proliferator-activated receptor {gamma} (PPAR{gamma}) and its coactivator PGC-1{alpha} is crucial for the normal physiology of PPAR{gamma} and its pharmacological response to antidiabetic treatment with rosiglitazone. Here we report the crystal structure of the PPAR{gamma} ligand-binding domain bound to rosiglitazone and to a large PGC-1{alpha} fragment that contains two LXXLL-related motifs. The structure reveals critical contacts mediated through the first LXXLL motif of PGC-1{alpha} and the PPAR{gamma} coactivator binding site. Through a combination of biochemical and structural studies, we demonstrate that the first LXXLL motif is the most potent among all nuclear receptor coactivator motifs tested, and only this motif of the two LXXLL-related motifs in PGC-1{alpha} is capable of binding to PPAR{gamma}. Our ...
Low-lying nuclear energy levels in "1"1"0In and "1"1"2In were determined from de-excitation #gamma#-rays produced with "1"0"7Ag(#alpha#,n#gamma#)-"1"1"0In, "1"0"8Pd("6Li,4n#gamma#)"1"1"0In, "1"0"9Ag(#alpha#,n#gamma#)"1"1"2In and "1"1"0Pd("6Li,4n#gamma#)"1"1"2In reactions. In addition, the "1"1"4In energy level structure was investigated with the "1"1"0Pd("7Li,3n#gamma#)"1"1"4In reaction. Properties of de-excitation #gamma#-rays were determined from #gamma#-#gamma# coincidence, excitation, and angular distribution measurements conducted with Ge(Li) and Ge(intr.) #gamma#-ray detectors. A sequence of intraconnected levels in each of "1"1"0,"1"1"2,"1"1"4In were assigned to the (#pi#g"-"1/sub 9/2/, #nu#h/sub 11/2/) configuration. For the "1"1"0,"1"1"2,"1"1"4In energy level schemes a model calculation has ...
An experimental study was performed in order to study the nuclear structure in odd--odd In isotopes. Low lying nuclear energy levels in "1"1"0In and "1"1"2In were determined from de-excitation #gamma#-rays produced with "1"0"7AG(#alpha#,n#gamma#)"1"1"0In, "1"0"8Pd("6Li,4n#gamma#)"1"1"0In, "1"0"9Ag(#alpha#,n#gamma#)"1"1"2In and "1"1"0Pd("6Li,4n#gamma#)"1"1"2In reactions. In addition, the "1"1"4In energy level structure was investigated with the "1"1"0Pd("7Li,3n#gamma#)"1"1"4In reaction. Properties of de-excitation #gamma#-rays were determined from #gamma#--#gamma# coincidence excitation and angular distribution measurements conducted with Ge(Li) and Ge(intr.) #gamma#-ray detectors. A sequence of intraconnected levels in each of "1"1"0 "1"1"2 "1"1"4In were assigned to the (#pi#"-"1/sub 9/2/, #nu#h/sub ...
We report a study of $B\\to (J/\\psi \\gamma) K$ and $B\\to (\\psi' \\gamma)K$ decay modes using $772\\times 10^{6}$ $B\\bar{B}$ events collected at the \\Upsilon(4S)$ resonance with the Belle detector at the KEKB energy-asymmetric $e^+ e^-$ collider. We observe $X(3872) \\to J/\\psi \\gamma$ and report the first evidence for $\\chi_{c2} \\to J/\\psi \\gamma$ in $B\\to (X_{c\\bar{c}}\\gamma) K$ decays, while in a search for $X(3872) \\to \\psi' \\gamma$ no significant signal is found. We measure the branching fractions, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) \\mathcal{B}(X(3872) \\to J/\\psi\\gamma)$ $=$ $(1.78^{+0.48}_{-0.44}\\pm 0.12)\\times 10^{-6}$, $\\mathcal{B} (B^{\\pm} \\to\\chi_{c2} K^{\\pm})$$=$ $(1.11^{+0.36}_{-0.34} \\pm 0.09) \\times 10^{-5}$, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) \\mathcal{B}(X(3872) \\to ...
In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas ...
We present results of an investigation to study CP violation in the Higgs sector in tt-bar production at a #gamma##gamma#-collider, via the process #gamma##gamma# #-># #phi# #-># tt-bar where the #phi# is a scalar with indeterminate CP parity. The study is performed in a model independent way parametrising the CP violating couplings in terms of six form factors #left brace#R(S_#gamma#), T(S_#gamma#), R(P_#gamma#), T(P_#gamma#), S_t, P_t#right brace#. The CP violation is reflected in the polarisation asymmetry of the produced top quark. We use the angular distribution of the decay lepton from t/t-bar as a diagnostic of this polarisation asymmetry and hence of the CP mixing, after showing that the asymmetries in the angular distribution are independent of any CP violation in the tbW vertex. We construct combined asymmetries in the initial state lepton ...
The CALPHAD (calculations of phase diagrams) method is used to examine the effects of applied magnetic fields on the {alpha}/{gamma} phase boundary in the Fe-Si system in the paramagnetic state. The reported susceptibility data for pure Fe is first re-evaluated. The contributions to the total Gibbs energy of the ferrite ({alpha}) and austenite ({gamma}) from the external fields are calculated based on the Curie-Weiss law and the re-evaluated susceptibility data. The Fe-Si phase diagram on the Fe-rich side as a function of applied field is calculated using the Thermo-Calc(TM) package. With increasing field strength, the {gamma} loop shrinks monotonically; that is, the {alpha}/{gamma}-Fe transition temperature increases while that for {gamma}/{delta}-Fe transition decreases, albeit more slowly. Finally, in conformance with the existing CALPHAD databank, Redlich-Kister polynomials are ...
The "7Be(#alpha#,#gamma#)"1"1C and "7Li(#alpha#,#gamma#)"1"1B reactions are investigated in the three-cluster Generator Coordinate Method. The microscopic wave functions are described from #alpha# and "3He ("3H) clusters, with two coupling modes: #alpha#+"7Be ("7Li) and "3He ("3H)+"8Be. Different internal states of "7Be ("7Li) and "8Be are taken into account. The model is tested on "1"1C and "1"1B spectroscopic properties, which agree fairly well with experiment. We suggest that, in both nuclei, the (3)/(2)"- and (5)/(2)"- states located close to the #alpha#+"7Be ("7Li) threshold, are intruder states. The "7Be(#alpha#,#gamma#)"1"1C and "7Li(#alpha#,#gamma#)"1"1B reaction rates are calculated for temperatures up to 10"9 K. A strong enhancement is found with respect to the reaction rates currently used in astrophysical calculations. ((orig.)).
We revisit the production of a single Higgs boson from direct \\gamma \\gamma -scattering at a photon collider. We compute the total cross section \\sigma(\\gamma \\gamma \\to h) (for h=h0, H0, A0), and the strength of the effective g_{h \\gamma \\gamma} coupling normalized to the Standard Model (SM), for both the general Two-Higgs-Doublet Model (2HDM) and the Minimal Supersymmetric Standard Model (MSSM). In both cases the predicted production rates for the CP-even (odd) states render up to 10^4 (10^3) events per 500 \\invfb of integrated luminosity, in full consistency with all the theoretical and phenomenological constraints. Depending on the channel the maximum rates can be larger or smaller than the SM expectations, but in most of the parameter space they should be well measurable. We analyze how these departures depend on the dynamics underlying each of the ...
We study double Higgs boson production at future linear colliders while paying special attention to the option of high-energy and high-luminosity photon beams. The main purpose is to examine the feasibility of {ital e}{sup +}{ital e}{sup {minus}}, {gamma}{ital e}, and {gamma}{gamma} colliders in order to establish bounds on the value of triple Higgs coupling, which could be crucial for understanding a spontaneous breaking mechanism. We consider mainly those cases of light and intermediate Higgs bosons, including an analysis of the electroweak backgrounds. The mass range {ital M}{sub {ital H}}{approximately}{ital M}{sub {ital Z}} is discussed separately. It is shown that for a light Higgs boson the {ital H}{sup 3} coupling can be visible, even at a future linear {ital e}{sup +}{ital e}{sup {minus}} collider at 500 GeV. For an intermediate Higgs boson, a collider with TeV energies is suitable for investigations. We estimate the bounds on the ...
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.
The next-to-leading-order (NLO) cross section for the production of heavy quarks at large transverse momenta #gamma##gamma# collision is calculated with perturbative fragmentation functions (PFF). This approach allows for a resummation of terms #propor to# #alpha#_sln(p"2/m"2) which arise in NLO from collinear emission of gluons by a heavy quark at large p or from almost collinear branching of photons or gluons into heavy-quark pairs. It is presented single-inclusive distributions in p and rapidity including direct and resolved photons for #gamma##gamma# production of heavy quarks at e"+e"-colliders and at high-energy #gamma##gamma# colliders. The results are compared with fixed- order calculation for m finite including QDC radiative corrections. The two approaches differ in the definitions and relative contributions of the direct and resolved terms, but essentially agree in their sum. The resummation of the ...
In the execution of disposal of low and intermediate level radioactive wastes, it is important to evaluate accurately the kind and quantity of each radionuclide in the wastes. For such an evaluation, correlation of non-gamma-emitting nuclides based on gamma-emitting nuclides is recommended and regarded as a partial method. This method necessitates a completion of a highly accurate and reliable nondestructive assay system of gamma-emitting nuclides for partical use. In 1992, in support of the new waste disposal program in Hungary, Paks NPP initiated a waste characterization program to determine the radiological properties of its rad wastes. A segmented gamma scanning system has been set up to measure the gamma-emitting nuclides in 2000 litre low level drums following in-drum compaction. In the framework of the program a radiochemical analysis sub-program was stated to determine the ...
Complete factorization scheme analysis of $F_2^{\\gamma}(x,Q^2)$ in the next--to--leading order QCD is performed. It is shown that the presence of the inhomogenous term in the evolution equations for parton distribution functions of the photon implies qualitative change in the way factorization mechanism works in photon--hadron and photon--photon collisions as compared to hadron--hadron ones. The incompletness of the existing NLO analyses of $F_2^{\\gamma}(x,Q^2)$ is pointed out and its origins traced back to the misinterpretation of the behaviour of $q^{\\gamma}(x,M)$ as a function of in the LO photonic coefficient function $C_{\\gamma}^{(0)}(x)$ is given and smooth transition between the properties of virtual and real photon discussed. A simple way of avoiding the problems with the term $\\ln(1-x)$ appearing in the standard expression for $C_{\\gamma}^{(0)}(x)$ in the case of the ...
Some models for quantum gravity (QG) violate Lorentz invariance and predict an energy dependence of the speed of light, leading to a dispersion of high-energy gamma-ray signals that travel over cosmological distances. Limits on the dispersion from short-duration substructures observed in gamma-rays emitted by gamma-ray bursts (GRBs) at cosmological distances have provided interesting bounds on Lorentz invariance violation (LIV). Recent observations of unprecedentedly fast flares in the very-high energy gamma-ray emission of the active galactic nuclei (AGNs) Mkn 501 in 2005 and PKS 2155-304 in 2006 resulted in the most constraining limits on LIV from light-travel observations, approaching the Planck mass scale, at which QG effects are assumed to become important. I review the current status of LIV searches using GRBs and AGN flare events, and discuss limitations of light-travel time analyses and ...
Diffuse {gamma}-ray emission produced by the interaction of cosmic-ray particles with matter and radiation in the Galaxy can be used to probe the distribution of cosmic rays and their sources in different regions of the Galaxy. With its large field of view and long observation time, the Milagro Gamma Ray Observatory is an ideal instrument for surveying large regions of the Northern Hemisphere sky and for detecting diffuse {gamma}-ray emission at very high energies. Here, the spatial distribution and the flux of the diffuse {gamma}-ray emission in the TeV energy range with a median energy of 15 TeV for Galactic longitudes between 30{sup o} and 110{sup o} and between 136{sup o} and 216{sup o} and for Galactic latitudes between -10{sup o} and 10{sup o} are determined. The measured fluxes are consistent with predictions of the GALPROP model everywhere except for the Cygnus region (l {element_of} [65{sup o}, ...
Thermal analysis testing revealed slight weight changes, which were a function of gamma irradiation, in a highly reduced Defense Waste Processing Facility (DWPF) simulated waste glass. Transmission electron microscopy (TEM) was performed on this glass to determine if the weight change corresponded to microstructural variations. TEM analyses showed that no microstructural changes were attributable to gamma irradiation. Exposure of the samples to the electron beam in the TEM did cause changes in the glass microstructures in some cases. These changes were likely due to localized heating of the glass due to interactions with the transmitted electrons.
We analyse data on forward {eta} -meson photoproduction off a proton target and extract the {eta}{yields}{gamma}{gamma} decay width utilizing the Primakoff effect. The hadronic amplitude that enters into our analysis is strongly constrained because it is fixed from a global fit to available {gamma}p{yields}p{eta} data for differential cross-sections and polarizations. We compare our results with present information on the two-photon {eta} -decay from the literature. We provide predictions for future PrimEx experiments at Jefferson Laboratory in order to motivate further studies. (orig.)
When polarized electrons traverse a region where the laser light is focused their polarization varies even if their energy and direction of motion are not changed. This effect is due to interference of the incoming electron wave and an electron wave scattered at zero angle. Equations are obtained which determine the variation of the electron-density matrix, and their solutions are given. The change in the electron polarization depends not only on the Compton cross section but on the real part of the forward Compton amplitude as well. It should be taken into account, for example, in simulations of the e{yields}{gamma} conversion for future {gamma}{gamma} colliders. (orig.). 16 refs.
When polarized electrons traverse a region where the laser light is focused their polarization varies even if their energy and direction of motion are not changed. This effect is due to interference of the incoming electron wave and an electron wave scattered at zero angle. Equations are obtained which determine the variation of the electron-density matrix, and their solutions are given. The change in the electron polarization depends not only on the Compton cross section but on the real part of the forward Compton amplitude as well. It should be taken into account, for example, in simulations of the e#->##gamma# conversion for future #gamma##gamma# colliders. (orig.).
The effect of pigments on the development of corrosion products between the painting system and metal surface when exposed to marine environments has been discussed. The pigments studied were: red mud zinc chromate, zinc chromate, red oxide zinc phosphate, manganese phosphate barium chromate and basic lead silico chromate. Moessbauer spectroscopy revealed that the upper rust layer in all the cases consisted of #gamma#-Fe_2O_3, #gamma#-FeOOH and #alpha#-FeOOH. The lower rust layer immediately in contact with the metal surface consisted of an asymmetrical doublet due to #gamma#-FeOOH. (Auth.).
The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).
Inactivation of aflatoxin B1 was studied by using gamma radiation and hydrogen peroxide. A 100-krad dose of gamma radiation was sufficient to inactivate 50 micrograms of aflatoxin B1 in the presence of 5% hydrogen peroxide, and 400 krad was required for total degradation of 100 micrograms of aflatoxin in the same system. Degradation of aflatoxin B1 was confirmed by high-pressure liquid chromatographic and thin-layer chromatographic analysis. Ames microsomal mutagenicity test showed loss of aflatoxin activity. This method of detoxification also reduces the toxin levels effectively in artificially contaminated groundnuts.
The paper describes an application of the tree classification method Random Forest (RF), as used in the analysis of data from the ground-based gamma telescope MAGIC. In such telescopes, cosmic gamma-rays are observed and have to be discriminated against a dominating background of hadronic cosmic-ray particles. We describe the application of RF for this gamma/hadron separation. The RF method often shows superior performance in comparison with traditional semi-empirical techniques. Critical issues of the method and its implementation are discussed. An application of the RF method for estimation of a continuous parameter from related variables, rather than discrete classes, is also discussed.
The use of uranium mill tailings in the foundations of dwellings has resulted in indoor radon progeny concentrations and gamma exposures in excess of levels presently allowed for the general public. An account is given of the applications of an epoxy coating on the indoor faces of the concrete foundations of three buildings in Grand Junction, Colorado. Epoxy barriers were shown to be effective for preventing radon influx into structures. Gamma exposure rates must be analyzed to ensure that buildup behind the barrier will not introduce an unacceptable gamma exposure level. The use of a sealant is especially economical in situations where structural integrity may be jeopardized by physical removal of uranium mill tailings. (author).
The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories covering both borehole logging and on-line analysis on conveyor belt ...
The reaction {gamma}d{yields}{pi}{sup +}nn is calculated up to order {chi}{sup 5/2} in chiral perturbation theory, where {chi} denotes the ratio of the pion to the nucleon mass. Special emphasis is put on the role of nucleon recoil corrections that are the source of contributions with fractional power in {chi}. Using the known near-threshold production amplitude for {gamma}p{yields}{pi}{sup +}n as the only input, the total cross-section for {gamma}d{yields}{pi}{sup +}nn is described very well. A conservative estimate suggests that the theoretical uncertainty for the transition operator amounts to 3% for the computed amplitude near threshold. (orig.)
Effects of #gamma#-irradiation on synthetic polymers and paper used as packaging materials for irradiated food have been studied by NMR. Polystyrene, polybutadiene and some copolymers were studied before and after the #gamma#-irradiation treatment and in the presence or absence of antioxidants and stabilisers. In the absence of additives, the effect of #gamma#-irradiation on polystyrene is negligible even irradiating at high doses. In turn, the role of antioxidants and stabilisers is crucial in polybutadiene and butadiene-containing copolymers. Wood pulp paper was also studied by NMR. Preliminary measurements on #gamma#-irradiated wood pulp sheets show a shortening in the T_2 relaxation time component due to the bound water, i.e. some of the bound water is lost. (author)
The energy level schemes of tin isotopes produced in the heavy ion reactions are presented. The using of #gamma# spectroscopy technique is also described. 4 refs, 12 figs.
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.
The energy level schemes of {sup 152}Gd and {sup 152}Sm have been established on the basis of single gamma-spectra, and gamma-gamma coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/beta{sup +} and beta{sup -} decays of {sup 152}Eu to {sup 152}Sm and {sup 152}Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).
The energy level schemes of "1"5"2Gd and "1"5"2Sm have been established on the basis of single #gamma#-spectra, and #gamma#-#gamma# coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/#beta#"+ and #beta#"- decays of "1"5"2Eu to "1"5"2Sm and "1"5"2Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).
Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).
An application that provides a flexible and easy to use interface to the GAMMA spectral simulation package is described that is targeted at investigations using in vivo MR spectroscopic methods....Full Text Available
The phase transformations and properties of a precipitation-hardened Ni-Cr-based alloy are investigated as a function of C, B, Nb, and Cr contents. It is found that the primary role of Nb consists in the formation of an independent phase, delta-Ni3Nb, a part of a gamma/gamma-prime-delta eutectoid (for high C and B concentrations) and in stimulating the gamma-sigma reaction consecutively with the gamma double prime-delta reaction (for low C and B concentrations). In both cases, the long-term strength characteristics of the Nb-alloyed system are relatively low. The substitution of boron for carbon contributes to a reduction in the number of nucleation sites for topologically close-packed phases and to the formation of more stable (with respect to excess compounds) M3B2 and MB2 borides. The high-boron material exhibits better properties and phase stability under mechanical and thermal loading. 13 references.
Pro-inflammatory cytokines may directly influence the viability and metabolic function of colonic epithelial cells (CEC) as an early event in the development of inflammatory bowel disease. We report here that TNF-alpha+IFN-gamma induced a synergistic, concentration-dependent decline in butyrate oxidation, an essential energy supply, in HT-29 and DLD-1 cells. TNF-alpha+IFN-gamma induced a parallel profound decline in cell viability in HT-29 cells, but not in DLD-1 cells, where impairment of butyrate oxidation seemed to precede later occurrence of cell damage. TNF-alpha+INF-gamma induced CEC damage was independent on NO formation and involved the IFN-gamma signalling pathway as well as induction of apoptosis. If cytokines have similar effects in vivo, these may lead to energy deficiency and thus contribute to CEC damage and disturbance of the epithelial integrity.
Recently, foods are often exposed to radiation under packed states with various wrapping materials. In this study, the effects of #gamma#-ray radiation were investigated on the additives in wrapping materials on the market. 10 - 50 kGy #gamma# radiation was irradiated to samples under sealed condition in a glass-ware. Polyethylene bag and wrapping film, polypropylene wrapping film, cup and sheet, and polystyrene cup were used as samples. And the additives in these materials were analyzed by GC/MS to evaluate the radiation effects on them. The irradiation was found to induce rapid degradation of antioxidants, especially, Irgafos 168. Some fatty acid amides used as a lubricant and a plasticizer, DBP were also reduced, but not aliphatic hydrocarbons. However, all polystyrene products used in this study included no additives. The contents of styrene dimer and trimer in those wrapping materials were not changed by ...
The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).
A plutonium gamma-ray analysis system that operates on MS-DOS-based computers has been developed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra for plutonium isotopics. The program titled IAEAPU consists of three separate applications: a data-transfer application for transferring spectral data from a CICERO multichannel analyzer to a binary data file, a data-analysis application to analyze plutonium gamma-ray spectra, for plutonium isotopic ratios and weight percents of total plutonium, and a data-quality assurance application to check spectral data for proper data-acquisition setup and performance. Volume 3 contains the software listings for these applications.