International Nuclear Information System (INIS)
The radioactive decay of "2"0"3Bi is studied. A level scheme is proposed for "2"0"3Pb on the basis of #gamma#-ray and electron spectra and #gamma#-#gamma# coincidence measurements. The experimental data are compared with theoretical results obtained in a three quasiparticle approximation. (Auth.).
Gamma-ray spectra from neutron capture on /sup 87/Sr
Energy Technology Data Exchange (ETDEWEB)
The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.
1981-07-01
#gamma##gamma# Cross-sections and #gamma##gamma# colliders
International Nuclear Information System (INIS)
We summarize the predictions of different models for total #gamma##gamma# cross-sections. The experimentally observed rise of #sigma#_#gamma#_#gamma# with s radical _#gamma#_#gamma#, faster than that for #sigma#_p_-_b_a_r_p, #sigma#_#gamma#_p is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of #sigma#_#gamma#_#gamma# with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range 300< s radical_#gamma#_#gamma# <500 GeV. We further show that the difference in ...
2001-10-11
Energy Technology Data Exchange (ETDEWEB)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a ...
1983-01-01
International Nuclear Information System (INIS)
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a ...
7871-01-01
In-beam spectroscopy of nuclei
International Nuclear Information System (INIS)
The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).
1982-01-01
Quick separation of fission product molybdenum and gamma-rays of Mo-102
International Nuclear Information System (INIS)
... electrophoresis fission products gamma radiation gamma spectra half-life
Investigation of W"1"7"7 decay scheme by #gamma##gamma#-coincidence method
International Nuclear Information System (INIS)
... coincidence spectrometry decay excited states gamma spectra half-life
1973-01-29
International Nuclear Information System (INIS)
The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.
1987-09-14
{gamma}{gamma} Cross-sections and {gamma}{gamma} colliders
Energy Technology Data Exchange (ETDEWEB)
We summarize the predictions of different models for total {gamma}{gamma} cross-sections. The experimentally observed rise of {sigma}{sub {gamma}}{sub {gamma}} with s radical {sub {gamma}}{sub {gamma}}, faster than that for {sigma}{sub p-barp}, {sigma}{sub {gamma}}{sub p} is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of {sigma}{sub {gamma}}{sub {gamma}} with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for ...
2001-10-11
Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction
Energy Technology Data Exchange (ETDEWEB)
Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.
1999-02-01
Energy Technology Data Exchange (ETDEWEB)
Energy spectra of the Bragg reflection of the Moessbauer ..gamma..-radiation from the /sup 57/Fe/sub 3/BO/sub 6/ weakly ferromagnetic monocrystal are studied. A strong effect of the interference transitions in iron nuclei, being in non-equivalent positions, on the spectra form is revealed. The measurement results are compared with theoretical calculations.
1984-05-25
GAMMA SPECTRA AND PERIODS OF FOUR ODD-A ISOTOPES OF TUNGSTEN AND TANTALUM
The gamma spectra and lifetimes of the Ta and W isotopes havimg mass numbers 173, 175, 177, and 179 are determined. (T.F.H.)
1963-06-01
ESR spectra of radicals of gamma-irradiated wood and cellulose
International Nuclear Information System (INIS)
Spectra of e.p.r. radicals in cellulose and timber gamma-irradiated at 77 and 300 K have been measured. Radiation yields and the kinetics of radicals accumulation have been studied. The effect of ionizing radiation on cellulose is the appearance of radicals resulting from rupture of C-H bonds in positions 1 and 4. Timber, additionally, forms ''lignin'' radicals. A mechanism of cellulose and timber radiolysis is suggested. ''Lignin''-type compounds present in timber protect polysaccharides from radiation-induced destruction.
Levels in sup 152 Gd and sup 152 Sm populated by the decay of sup 152 Eu
Energy Technology Data Exchange (ETDEWEB)
The energy level schemes of {sup 152}Gd and {sup 152}Sm have been established on the basis of single gamma-spectra, and gamma-gamma coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/beta{sup +} and beta{sup -} decays of {sup 152}Eu to {sup 152}Sm and {sup 152}Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).
1990-01-01
Levels in "1"5"2Gd and "1"5"2Sm populated by the decay of "1"5"2Eu
International Nuclear Information System (INIS)
The energy level schemes of "1"5"2Gd and "1"5"2Sm have been established on the basis of single #gamma#-spectra, and #gamma#-#gamma# coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/#beta#"+ and #beta#"- decays of "1"5"2Eu to "1"5"2Sm and "1"5"2Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a ...
1997-05-01
Origin of {gamma}-rays from young open clusters
Energy Technology Data Exchange (ETDEWEB)
The young open cluster Berkeley 87 was predicted to be associated with the COS B {gamma}-ray source 2CG 075+00 on the basis of the experimental evidence of the presence of a shock front around the Wolf - Rayet star ST3 placed in the inner part of the cluster. The CGRO phase-1 data confirm this identification. Protons accelerated at the shock boundary can produce {pi} deg. via p-p interactions and then {gamma}-rays. With the measured flux F{sub {gamma}} (E > 100 MeV) {approx_equal} 9x10{sup -7} ph cm{sup -2} s{sup -1} and the power-law proton spectrum with spectral index {gamma} = 2, the cosmic-ray-energy-density in the inner part ({approx} 0.8 pc radius) of Berk 87 is about 100 times greater than that in the vicinity of the Earth. We have calculated {gamma}-ray spectra expected from the decay of {pi}{sup d}eg. produced in p-p ...
1996-08-01
Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr
Energy Technology Data Exchange (ETDEWEB)
Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.
1985-01-15
Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr
International Nuclear Information System (INIS)
Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.
1984-09-10
FFTF reactor characterization program
International Nuclear Information System (INIS)
Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the ...
International Nuclear Information System (INIS)
These experiments were performed on the Isocele separator, on-line with the Orsay synchrocyclotron; thulium isotopes were produced by bombarding natural erbium targets with 150nA beam of 157MeV protons. Two Ge(Li) detectors, with resolution of 2.3 and 2.5keV at 1332keV used for #gamma#-ray measurements; conversion electron spectra were measured using a Si(Li) detector. #gamma# spectra, #gamma#-#gamma# coincidence and conversion electron measurements were sufficient to build the flow energy level schemes of the transitional "1"5"8Er and "1"5"6Er nuclei. On both nuclei several quasi rotational bands have been identified. These results are compared with other even erbium isotopes and with the neighboring N=88 and 90 isotones. Comparisons with predictions issued from some classical models are also performed: "1"5"8Er appears ...
1976-01-01
Infrared stimulated luminescence and phosphorescence spectra of irradiated feldspars
International Nuclear Information System (INIS)
A new high-sensitivity wide-bandwidth 1.25-5.5 eV (225-1000 nm) spectrometer has been constructed to measure luminescence emission spectra of minerals that are of interest for optical dating. Spectra of emission resulting from 1.43 eV (IR) excitation after #gamma#-irradiation are reported for 13 cut rock feldspars and 20 feldspar separates. Also reported are phosphorescence spectra following #gamma#-irradiation, and after 1.4 eV excitation. The main differences between the infrared stimulated luminescence spectra and the phosphorescence is the almost complete absence of the violet, 3.1 eV, and yellow-green, 2.2 eV, bands in the phosphorescence, and the presence of a green emission band centred at 2.7 eV in the phosphorescence following #gamma#-irradiation (but absent in the phosphorescence following 1.4 eV excitation). ...
2003-11-26
Energy Technology Data Exchange (ETDEWEB)
Medicinal plants i.e. dried seeds of myristica argentea, myristica fragrans, coriandrum sativum and foeniculum vulgare were stored for 0 and 6 months, with and without gamma irradiation at 5 kGy. No detectable changes were seen in infrared and UV spectra, GLC chromatograms and refraction indices of steam distilled, essential oils from the irradiated medicinal plants. The same results were also obtained from irradiated samples stored for 6 months at ambient conditions. Storage for 6 months caused significant changes in the gas liquid chromatograms and UV spectra of all samples compared to non-stored samples. The moisture content of all samples packed in polyethylene bags seems to be constant after 6 months of storage. No measurable changes were found in the amount of essential oil content caused by irradiation.
1981-10-01
Recent data from CREAM seem to confirm early suggestions that primary cosmic ray spectra at few TeV/nucleon are harder than in the 10-100 GeV range. Also, helium and heavier nuclei spectra appear systematically harder than the proton fluxes at corresponding energies. We note here that if the measurements reflect intrinsic features in the interstellar fluxes, appreciable modifications are expected in the sub-TeV range for the secondary yields, such as antiprotons and diffuse gamma-rays. Presently, this effect represents a systematic error in the extraction of astrophysical parameters as well as for background estimates for indirect dark matter searches. We find that the spectral modifications are appreciable above 100 GeV, and can be responsible for ~30% effects for antiprotons at energies close to 1 TeV or for gamma's at energies close to 300 GeV, compared to currently considered ...
2010-01-01
Development of a neutron/. gamma. ray radiation monitor
Energy Technology Data Exchange (ETDEWEB)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in ...
1983-01-01
Development of a neutron/#gamma# ray radiation monitor
International Nuclear Information System (INIS)
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the ...
1983-01-01
Development of a Neutron/gamma Ray Radiation Monitor.
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau ...
1983-01-01
Yields of short-lived fission products produced following "2"3"5U(n_t_h,f)
International Nuclear Information System (INIS)
Measurements of gamma-ray spectra, following the thermal neutron fission of "2"3"5U have been made using a high purity germanium detector at the University of Massachusetts Lowell (UML) Van de Graaff facility. The gamma spectra were measured at delay times ranging from 0.2 s to nearly 10000 s following the rapid transfer of the fission fragments with a helium-jet system. On the basis of the known gamma transitions, forty isotopes have been identified and studied. By measuring the relative intensities of these transitions, the relative yields of the various precursor nuclides have been calculated. The results are compared with the recommended values listed in the ENDF/B-VI fission product data base (for the lifetimes and the relative yields) and those published in the Nuclear Data Sheets (for the beta branching ratios). ...
1998-08-01
Neutron resonances in /sup 100/Mo and valence neutron capture
Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.
1979-07-01
In this work we develop a new propagation model for the Galactic cosmic rays based on the GALPROP code, including contributions from dark matter annihilation. The model predicts compatible Galactic diffuse $\\gamma$ ray spectra with EGRET data in all sky regions. It also gives consistent results of the diffuse $\\gamma$ ray longitude and latitude distributions. Further the results for B/C, $^{10}$Be/$^9$Be, proton, electron and antiproton spectra are also consistent with cosmic ray measurements. In the model we have taken a universal proton spectrum throughout the Galaxy without introducing large fluctuation for the proton energy loss is negligible. The dark matter annihilation signals are `boosted' after taking the contribution from subhalos into account. Another interesting feature of the model is that it gives better description of the diffuse $\\gamma$ rays ...
2007-01-01
Preparation of carrier-free yttrium-88 from strontium target by solvent extraction
International Nuclear Information System (INIS)
... carrier-free isotopes chemical preparation gamma spectra isotope production
International Nuclear Information System (INIS)
... activation analysis gamma spectra mev range molybdenum molybdenum ores
8"+ isomers in N=48 isotones and E2 polarization charges
International Nuclear Information System (INIS)
... charges energy levels gamma spectra half-life isomeric nuclei kev range
1972-05-01
Experimental measurements were made of the production cross sections and energy distributions of gamma rays emitted when the stable targets /sup 88/Sr, /sup 89/Y and /sup 90/Zr are exposed to protons in the energy range 3 to 8 MeV. The data are being analyzed using a recent version of the Uhl statistical model code. One conclusion is that while the gamma-ray strength functions employed reproduce the proton capture cross sections, they do not achieve the same degree of hardness observed in the measured spectra. To do so, their lower energy regions must be modified; such changes, however, do not affect the capture cross sections. 7 references.
1978-09-01
Studies on natural radioactivity of some egyptian building materials
International Nuclear Information System (INIS)
Using high-resolution y-rays spectrometry, the natural radioactivity of 14 samples of natural and o manufactured Egyptian building materials have been investigated. The samples were collected from local market and construction sites. From the measured gamma-ray spectra, specific activities were determined. The radium equivalent activity in each sample was estimated. Radiological evaluations of these materials indicate that all materials meet the external gamma-ray dose limitation. Calculation of concentration indices by assuming a Markkanen room model is constructed from these materials, to find the excess gamma-ray dose taken over that received from the outdoors. The Austrian Standard ONORM S 5200 is used in testing the building materials.
2004-02-24
Studies of the low-lying levels in /sup 192/Pt and /sup 192/Os
Energy Technology Data Exchange (ETDEWEB)
The energy level schemes of /sup 192/Os and /sup 192/Pt have been established on the basis of ..gamma..-..gamma.. coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and ..beta../sup -/ decays of /sup 192/Ir to /sup 192/Os and /sup 192/Pt, respectively. Thirteen new transitions and three new levels at 1146.95, 1237.35 and 1913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, ..cap alpha..(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition.
1985-02-01
Studies of the low-lying levels in "1"9"2Pt and "1"9"2Os
International Nuclear Information System (INIS)
The energy level schemes of "1"9"2Os and "1"9"2Pt have been established on the basis of #gamma#-#gamma# coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and #beta#"- decays of "1"9"2Ir to "1"9"2Os and "1"9"2Pt, respectively. Thirteen new transitions and three new levels at 1,146.95, 1,237.35 and 1,913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, #alpha#(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition. (orig.).
1985-01-01
Prompt fission neutron energy spectra induced by fast neutrons
International Nuclear Information System (INIS)
Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with ...
Energy Technology Data Exchange (ETDEWEB)
Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated ...
1985-03-01
Energy Technology Data Exchange (ETDEWEB)
This work concerns the development of nuclear energy and nuclear waste management in particular. Two parts of this study can be distinguished. In the first part (theoretical), a thorium-plutonium fuel based on MOX and dedicated for PWR was investigated in order to transmute plutonium in a potentially low waste fuel cycle. It was shown that this type of fuel is not regenerative but could be used for a transition to the industrial thorium fuel cycle without building new reactors. Thanks to moderated neutron spectra and high loaded actinide mass in the core, U-233 is quickly created ({approx}300 kg/y) for a loss of about {approx}1200 kg of fissile plutonium. In the second part (experimental), we have developed and built a new reaction chamber to measure neutron cross sections of actinides by alpha-gamma spectroscopy. This experimental device (in principle transportable) was commissioned in the high flux reactor of ILL ...
2002-09-01
CP property of the Higgs at the #gamma##gamma# colliders using tt-bar production
International Nuclear Information System (INIS)
We present results of an investigation to study CP violation in the Higgs sector in tt-bar production at a #gamma##gamma#-collider, via the process #gamma##gamma# #-># #phi# #-># tt-bar where the #phi# is a scalar with indeterminate CP parity. The study is performed in a model independent way parametrising the CP violating couplings in terms of six form factors #left brace#R(S_#gamma#), T(S_#gamma#), R(P_#gamma#), T(P_#gamma#), S_t, P_t#right brace#. The CP violation is reflected in the polarisation asymmetry of the produced top quark. We use the angular distribution of the decay lepton from t/t-bar as a diagnostic of this polarisation asymmetry and hence of the CP mixing, after showing that the asymmetries in the angular distribution are independent of any CP violation in the tbW vertex. We construct combined asymmetries in the initial state lepton ...
2003-09-01
International Nuclear Information System (INIS)
The results of investigation into a new series of Z-even nuclei - precursors of delayed protons (PDP) -"6"5Ge, "8"9Se, "9"3Kr, "8"1Zr, and "8"5Mo are presented. PDP were obtained by irradiation of targets in the following reactions: Zn(He, 2n) "6"5Ge, 22 MeV; "4"0Ca("3"2S, 2 pn) "1"9Se, 100 MeV; "6"0Ni ("1"60, 3 n), "7"3Kr, 75 MeV; "5"2Cr ("3"2S, 3n)"8"1Zr, 110 MeV; "5"6Fe("3"2S, 3n)"8"5Mo, 120 MeV. The targets (self-sustaining foils of thickness approximately 1.2 mg/cm"2) were placed at an angle of 15 deg to the direction of the ion beam. Upon irradiation targets were moved downwards into a measuring position. The spectra of protons, X and gamma-rays, and also the spectra of p - x, p-#gamma#, x - #gamma# coincidences accompanying the decay of "6"5Ge, "6"9Se,"7"3Kr and "8"1Zr, and "8"5Mo were measured. The measured ...
Particle emission from low energy nuclear reactions in solids. Preliminary results
Energy Technology Data Exchange (ETDEWEB)
TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons or deuterons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Deuteron irradiation of TiD{sub 2} produced these observations: copious {approx}2.5 MeV neutrons and {approx}3 MeV protons from direct D-D reactions; gamma rays from p,{gamma} and n,{gamma} reactions; {approx}14 MeV protons from the secondary d({sup 3}He, p){alpha} reaction; and a signal between {approx}6-12 MeV that Kasagi et al. has tentatively identified as protons from the fusion of three deuterium nuclei. However, this signal has in it a strong interference signal from either neutrons or gamma rays that directly deposit energy in the detector. This interference spectra was measured by placing a thick absorber in front of the detector that stops up to 20 MeV protons, but ...
2000-07-01
International Nuclear Information System (INIS)
It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).
Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions
International Nuclear Information System (INIS)
The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are ...
International Nuclear Information System (INIS)
This paper first introduces the calculating method of radium specific activity to determine the radon emanation rate of tailing of uranium mine No. 794, the method needs two parameters: radon emanation coefficient and radon diffusion coefficient. According to the measured results of parameters and the contrast between radium specific activity of indoor chemical analysis of field sample and field gamma-ray spectra, the authors discuss the variation rules and characteristics of radon emanation coefficient and radon diffusion coefficient, and the best climate and seasons for measuring these parameters in northern China, and finally summarize the characteristics of this method through analyzing measured results. (authors)
2006-09-01
Neutron resonances in "1"0"0Mo and valence neutron capture
International Nuclear Information System (INIS)
Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.
Measuring the beam polarizations and the luminosity at photon-photon colliders
Energy Technology Data Exchange (ETDEWEB)
We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)
1993-11-01
Energy Technology Data Exchange (ETDEWEB)
Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an ...
2006-07-01
Three-particle and anomalous excited states of "1"0"1Tc nucleus
International Nuclear Information System (INIS)
... energy levels excited states gamma spectra internal conversion li-drifted ge
1973-01-29
The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)
International Nuclear Information System (INIS)
The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories ...
2009-04-15
Strongly perturbed rotational bands in the "1"8"7Ir and "1"8"9Ir
International Nuclear Information System (INIS)
... alpha beams energy-level transitions gamma spectra iridium 187 iridium 189
1973-06-19
Levels in "9"7Tc, "9"9Tc, "1"0"1Tc and "1"0"1Ru
International Nuclear Information System (INIS)
... Thesis (Ph.D.). coincidence spectrometry excited states gamma spectra internal
Study on the angular. gamma gamma. -correlations for nuclei of Sr even-even isotopes
Energy Technology Data Exchange (ETDEWEB)
The angular ..gamma gamma..-correlations for nuclei of Sr even-even isotopes with A=82, 84, 86, 88 were measured. Multipole structurs of ..gamma..-transtion series and th coefficients multipole mixing were determined.
1984-05-01
Study on the angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes
International Nuclear Information System (INIS)
The angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes with a=8 82, 84, 86, 88 were measured. Multipole structurs of #gamma#-transtion series and th coefficients multipole mixing were determined.
1983-04-01
Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences
The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)
1973-08-01
Semihard production of tensor mesons in #gamma##gamma#-collisions and the perturbative Odderon
International Nuclear Information System (INIS)
The cross sections of neutral tensor mesons T=a_2, f, f', ... production in the exclusive #gamma##gamma##->#TT' or semiexclusive #gamma##gamma##->#TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV"2 are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future #gamma##gamma#-colliders is discussed too. (orig.).
A study of electrochemically-induced corrosion of low carbon steel in a medium modelling acid rain
Energy Technology Data Exchange (ETDEWEB)
Complementary electrochemical, spectrophotometric and electron microsopic investigations were made in addition to the conversion electron Moessbauer spectroscopic (CEMS) measurements to learn more about the mechanism of corrosion of low carbon steel samples in aqueous sulfate and sulfite containing sulfate solutions (pH 3.5, 6.5 and 8.5). Passivation of iron in pure sulfate solution was studied in detail in earlier papers. In the present work, we used a solution containing both sulfate and sulfite anions to obtain more information about the effect of acid rain on low carbon steel samples. The compositions and thicknesses of the passive films formed due to the electrochemical treatments were determined from the CEM spectra. [gamma]-FeOOH was found in each case on the surface of the samples; nevertheless, at pH 3.5 the sextet belonging to Fe[sub 3]C appears in the CEM spectra, and also FeSO[sub 4] . H[sub ...
1994-11-01
An MS-DOS-based program for analyzing plutonium gamma-ray spectra
Energy Technology Data Exchange (ETDEWEB)
A plutonium gamma-ray analysis system that operates on MS-DOS-based computers has been developed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra for plutonium isotopics. The program titled IAEAPU consists of three separate applications: a data-transfer application for transferring spectral data from a CICERO multichannel analyzer to a binary data file, a data-analysis application to analyze plutonium gamma-ray spectra, for plutonium isotopic ratios and weight percents of total plutonium, and a data-quality assurance application to check spectral data for proper data-acquisition setup and performance. Volume 3 contains the software listings for these applications.
1989-09-07
DOE personnel neutron dosimetry evaluation and upgrade program
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, ...
1988-10-01
Measurement of electron energy fluence spectra from electron beam therapy machines
Energy Technology Data Exchange (ETDEWEB)
A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung ...
1984-01-01
Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in {sup 66}Fe
The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for {sup 61}Mn up through {sup 69}Mn. The 14(4)-ms half life for {sup 69}Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of {sup 64,66}Mn to levels of {sup 64,66}Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes. {copyright} {ital 1998 American Institute of Physics.}
1998-12-01
Decay of very neutron-rich Mn nuclides and vanishing of the N=40 subshell closure in "6"6Fe
International Nuclear Information System (INIS)
The use of chemically selective laser ionization combined with beta-delayed neutron counting at ISOLDE has permitted identification and half-life measurements for "6"1Mn up through "6"9Mn. The 14(4)-ms half life for "6"9Mn is one of the shortest determined for any nuclide beyond the sd shell. Gamma-ray singles and coincidence spectra have been determined for the decays of "6"4","6"6Mn to levels of "6"4","6"6Fe, revealing strong deformation and vanishing of the N=40 subshell in the Fe isotopes.
1998-12-21
Neutron flux spectra in the FFTF In-Reactor Thimble
Energy Technology Data Exchange (ETDEWEB)
Neutron spectra measured in the FFTF In-Reactor Thimble (IRT) by proton recoil proportional counters, proton recoil emulsions, and passive dosimeters have been evaluated and compared with each other and with three-dimensionl diffusion theory calculated spectra for the purpose of validating the passive dosimeter spectrum adjustment technique. The least squares data adjustment code, FERRET, was used to combine measured reaction rates, calculated spectra, and dosimeter cross sections, resulting in adjusted spectra and cross sections with uncertainties and correlations that properly account for uncertainties and correlations on the input parameters.
1982-12-01
Method and system for detecting explosives
Energy Technology Data Exchange (ETDEWEB)
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
2009-03-10
Explosives detection system and method
Energy Technology Data Exchange (ETDEWEB)
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
2007-12-11
Electrochemical and conversion electron Moessbauer study of corrosion induced by acid rain
Energy Technology Data Exchange (ETDEWEB)
The passivation of low carbon steel was studied in aqueous solution of 0.5M Na[sub 2]SO[sub 4]+0.001M NaHSO[sub 3] (pH 3.5, 6.5 and 8.5) which can be considered as a model of acid rain. The used conversion electron Moessbauer spectroscopy (CEMS) with the complementary electrochemical investigations proved that the sulfite ions induce pitting corrosion at pH 3.5 and 6.5, while the measurements showed much weaker pitting at pH 8.5. The compositions and thicknesses of the passive films formed during the electrochemical treatments are determined from the CEM spectra. Only [gamma]-FeOOH was found on the surface of the samples at pH 6.5 and 8.5. Nevertheless, at pH 3.5 the sextet belonging to Fe[sub 3]C appears in the spectra, and also FeSO[sub 4].H[sub 2]O could be detected in low concentration. (orig.).
1993-04-01
Gamma-rays and neutrinos from the pulsar wind nebulae
Energy Technology Data Exchange (ETDEWEB)
We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few ...
2005-08-01
A finite element study of gamma ray transport
Energy Technology Data Exchange (ETDEWEB)
A complete code based on the finite element method (FEM) is used to study the attenuation of gamma rays, of source energy 9 MeV, in simple homogeneous lead and water systems. The results are compared, in tables and graphs, with those produced by a Monte Carlo method of solution. In the comparison, particular attention is paid to the annihilation gamma rays generated by the pair production process, to energy deposition, and to the leakage spectra. A model, multilayer, slab shield, having a fission neutron source impinging on the left-hand face, is also solved by the FEM code, using data from a coupled neutron/gamma ray cross section library. The resulting neutron and gamma ray flux distributions, and the leakage spectra, are shown graphically. (author).
1990-01-01
Gamma-gamma collider based on Compton back-scattering
International Nuclear Information System (INIS)
A #gamma##gamma# collider would extend and complement the physics capability of a linear collider; e.g. it would be suitable for direct measurement of the partial decay width of a Higgs boson into two gamma quanta. This paper discusses choice of laser parameters, luminosity optimization, electron and laser parameters for a gamma- gamma collider as a second interaction region for the Next Linear Collider, laser path, and the lasers. It is concluded that a gamma- gamma collider is technically feasible; however it will require a significant investment in preparatory R ampersand D.
1996-08-25
Measurements of the CKM angle $\\gamma/\\phi_{3}$ at B-factories
The CKM angle $\\gamma/\\phi_{3}$ had been measured by two B-factories, the PEPII collider for the BaBar experiment and the KEKB collider for the Belle experiments. The present paper reports recent progress in $\\gamma/\\phi_{3}$.
2011-01-01
Observation of two charged bottomonium-like resonances
We report the observation of two narrow structures at 10610MeV/c^2 and 10650MeV/c^2 in the pi^{\\pm}Upsilon(nS) (n=1,2,3) and pi^{\\pm}h_b(mP) (m=1,2) mass spectra that are produced in association with a single charged pion in Upsilon(5S) decays. The measured masses and widths of the two structures averaged over the five final states are M_1=10608.4\\pm2.0MeV/c^2, Gamma_1=15.6\\pm2.5MeV and M_2=10653.2\\pm1.5MeV/c^2, Gamma_2=14.4\\pm3.2MeV. Analysis favors quantum numbers of I^G(J^P)=1^+(1^+) for both states. The results are obtained with a 121.4fb^{-1} data sample collected with the Belle detector near the Upsilon(5S) resonance, at the KEKB asymmetric-energy e+e- collider.
2011-01-01
Physical problems in proceses accompanying the laser conversion e#->##gamma#
International Nuclear Information System (INIS)
Physical processes in the region of laser conversion for the next Linear Colliders (NLC) are discussed. The main goal of this conversion is to obtain high-energy intense #gamma# beams for #gamma#e and #gamma##gamma# colliders. This conversion has important by-products: (i) one can observe here effect of nonlinear QED (in a strong external field)-production of e"+e"- pairs by a high-energy photon and emission of very high-energy photons by an electron; (ii) one can produce and observe here the invisible axion in colliding #gamma#_0e beams. The NQED effects also result in variation of the spectra of high-energy photons and an additional background. 12 refs., 12 figs., 1 tab.
Energy Technology Data Exchange (ETDEWEB)
Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values in keV). For the ...
1986-10-31
International Nuclear Information System (INIS)
Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma ...
Studying the triple-Higgs vertex in the process. gamma. gamma. yields HH at TeV energies
Energy Technology Data Exchange (ETDEWEB)
In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process {gamma}{gamma}{yields}HH are calculated. It is shown that the cross section is measurable at TeV {gamma}{gamma} colliders and is marginally sensitive to the triple-Higgs variation. (orig.).
1992-06-04
Studying the triple-Higgs vertex in the process #gamma##gamma##->#HH at TeV energies
International Nuclear Information System (INIS)
In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process #gamma##gamma##->#HH are calculated. It is shown that the cross section is measurable at TeV #gamma##gamma# colliders and is marginally sensitive to the triple-Higgs variation. (orig.).
Calculated fluence spectra at neutron therapy facilities
International Nuclear Information System (INIS)
The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).
1995-11-13
Semihard production of tensor mesons in. gamma. gamma. -collisions and the perturbative Odderon
Energy Technology Data Exchange (ETDEWEB)
The cross sections of neutral tensor mesons T=a{sub 2}, f, f', ... production in the exclusive {gamma}{gamma}{yields}TT' or semiexclusive {gamma}{gamma}{yields}TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV{sup 2} are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future {gamma}{gamma}-colliders is discussed too. (orig.).
1992-03-01
Radon generation and transport in and around a gold mine tailings dam in South Africa
Energy Technology Data Exchange (ETDEWEB)
Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to ...
2006-07-01
Simulation of statistical {gamma}-spectra of highly excited rare earth nuclei
Energy Technology Data Exchange (ETDEWEB)
The statistical {gamma}-spectra of highly excited even-even rare earth nuclei are simulated applying appropriate level density and strength function to a given nucleus. Hindrance effects due to K-conservation are taken into account. Simulations are compared to experimental data from the {sup 163}Dy({sup 3}He,{alpha}){sup 162}Dy and {sup 173}Yb({sup 3}He,{alpha}){sup 172}Yb reactions. The influence of the K quantum number at higher energies is discussed. 21 refs., 7 figs., 2 tabs.
1997-05-01
Delayed-neutron energy spectra following thermal-neutron-induced fission of Pu-239
Energy Technology Data Exchange (ETDEWEB)
Delayed-neutron (DN) energy spectra following thermal neutron induced fission of /sup 239/Pu as a function of time after fission have been measured, using the beta-neutron time-of-flight (TOF) spectrometer at the University of Lowell. Thermal/epithermal neutrons were produced on the 5.5-MV Van de Graaff accelerator using the /sup 7/Li(p,n)/sup 7/Be reaction. Time spectra over the neutron energy range of 0.01-4.0 MeV were measured for seven different time intervals after fission, each interval containing varying contributions from the six delayed neutrons groups. The DN energy spectra following induced thermal fission of /sup 239/Pu are compared to those resulting from induced thermal fission of /sup 235/U for each of the seven delay time intervals. Decomposition of the measured spectra into six-group DN spectra was ...
1987-01-01
RF plasma nitriding of severely deformed iron-based alloys
International Nuclear Information System (INIS)
The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10"-"5 bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of #epsilon# and #gamma#' nitrides in the compound layer, with a preferential formation of #gamma#' at the expense of the ...
2003-05-15
SUSY at e{gamma}/{gamma}{gamma} colliders
Energy Technology Data Exchange (ETDEWEB)
We investigate the sparticle production processes e{gamma} {yields} e tilde(Z tilde){sub 1} and {gamma}{gamma} {yields} (f tilde)(f tilde and bar) at high energy e{gamma} and {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e{gamma} colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e{gamma} {yields} (e tilde)(Z tilde){sub 1}. We show that the standard background processes e{gamma} {yields} {nu}W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes ...
1994-04-01
SUSY at e#gamma#/#gamma##gamma# colliders
International Nuclear Information System (INIS)
We investigate the sparticle production processes e#gamma# #-># e tilde(Z tilde)_1 and #gamma##gamma# #-># (f tilde)(f tilde and bar) at high energy e#gamma# and #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e#gamma# colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e#gamma# #-># (e tilde)(Z tilde)_1. We show that the standard background processes e#gamma# #-># #nu#W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e#gamma# #-># (e ...
1994-04-01
Levels in "7"2Se observed via in-beam gamma-ray spectroscopy in the "5"8Ni("1"6O,2p) reaction
International Nuclear Information System (INIS)
Levels in "7"2Se were observed via in-beam gamma spectroscopy following the "5"8Ni("1"6O,2p) reaction. Spectra and partial energy level schemes are shown. (3 figures) (U.S.).
1975-05-01
Energy Technology Data Exchange (ETDEWEB)
A technique for measurement of the energy spectra of fission fragments is discussed. The fine structure found in the spectra of fragments from spontaneous fission of {sup 242}Cm and fast-neutron fission of {sup 242{ital m}}Am is analyzed. The quantitative parameters of the structure and their analogy with the characteristics of cold fission are discussed.
1989-05-01
Mass-energy spectra of fission fragments in the reaction {sup 242m}Am(n{sub th},f)
Energy Technology Data Exchange (ETDEWEB)
The mass-energy spectra of the fragments of thermal fission of {sup 242m}Am are measured using the time-of-flight technique. The resulting mass-yield curve and peak-to-valley ratio agree with radiochemical data. The parameters of the kinetic energy distribution of the fragments are determined for the first time. Data on the fine structure of mass spectra in the region of cold fragmentation are presented. 15 refs., 4 figs.
1994-12-01
Energy Technology Data Exchange (ETDEWEB)
The O({alpha}) electroweak radiative corrections to {gamma}{gamma}{yields}WW{yields}4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for {gamma}{gamma}{yields}4f+{gamma}. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer {gamma}{gamma} - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over ...
2005-09-01
International Nuclear Information System (INIS)
The O(#alpha#) electroweak radiative corrections to #gamma##gamma##->#WW#->#4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for #gamma##gamma##->#4f+#gamma#. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer #gamma##gamma# - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over ...
2005-09-01
The decay modes $\\jpsi\\ar\\gamma\\pi^0, \\gamma\\eta$ and $\\gamma\\etap$ are analyzed using a data sample of 58 million $\\jpsi$ decays collected with the BESII detector at BEPC. The branching fractions are determined to be: $Br(\\jpsi\\ar\\gamma\\pi^0)=(3.13^{+0.65}_{-0.44})\\times10^{-5}$, $Br(\\jpsi\\ar\\gamma\\eta)=(11.23\\pm0.89)\\times10^{-4}$, and $Br(\\jpsi\\ar\\gamma\\etap)=(5.55\\pm0.44)\\times10^{-3}$, where the errors are combined statistical and systematic errors. The ratio of partial widths $\\Gamma(\\jpsi\\ar\\gamma\\etap)/\\Gamma(\\jpsi\\ar\\gamma\\eta)$ is measured to be $4.94\\pm0.40$, and the singlet-octet pseudoscalar mixing angle of $\\eta-\\etap$ system is determined to be $\\theta_{P}=(-22.08\\pm0.81)^{\\circ}$.
2006-01-01
Development of a real-time, neutron and gamma dosimeter
Energy Technology Data Exchange (ETDEWEB)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-07-01
Development of a real-time, neutron and gamma dosimeter
International Nuclear Information System (INIS)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-06-10
Energy Technology Data Exchange (ETDEWEB)
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
2009-10-15
International Nuclear Information System (INIS)
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
2009-10-01
International Nuclear Information System (INIS)
An easy and simple method for gamma assay of large multi gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following tow simple well known facts: Large and small samples of the same homogenous material have identical activities; the self attenuation of gamma line decreases as its energy increases. The method was successfully applied to NORM (Naturally Occurring Radioactive Material) large samples. This method doesn't require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed. (author)
THE EVOLUTION OF LYMAN LIMIT ABSORPTION SYSTEMS TO REDSHIFT SIX
International Nuclear Information System (INIS)
We have measured the redshift evolution of the density of Lyman limit systems (LLSs) in the intergalactic medium over the redshift range 0 < z < 6. We have used two new quasar samples to (1) improve coverage at z #approx# 1, with GALEX grism spectrograph observations of 50 quasars with 0.8 < z_e_m < 1.3, and (2) extend coverage to z #approx# 6, with Keck ESI spectra of 25 quasars with 4.17 < z_e_m < 5.99. Using these samples together with published data, we find that the number density of LLS per unit redshift, n(z), can be well fit by a simple evolution of the form n(z) = n_3_._5[(1 + z)/4.5]"#gamma# with n_3_._5 = 2.80 #+-# 0.33 and #gamma# = 1.94"+"0"."3"6_-_0_._3_2 for the entire range 0 < z < 6. We have also reanalyzed the evolution of damped Ly#alpha# systems (DLAs) in the redshift range 4 < z < 5 using our high-redshift quasar sample. We find a total of 17 DLAs and ...
2010-10-01
Strong-interaction effect measurements in sigma hyperonic atoms of W and Pb
Energy Technology Data Exchange (ETDEWEB)
Strong-interaction effects have been observed in the x-ray spectra of atoms formed with [Sigma][sup [minus
1993-03-01
Spatially resolved IR absorption spectroscopy by optical Stark modulation
Energy Technology Data Exchange (ETDEWEB)
The first application of optical Stark modulation has been applied to measure spatially precise Stark-modulated IR absorption spectra in a flame.
1982-12-01
Measurement of fast fluctuations of radiation intensity in pulsed charged particle accelerators
International Nuclear Information System (INIS)
... beam monitoring betatrons delay circuits errors fluctuations gamma radiation
Status of measurements of fission neutron spectra of Minor Actinides
International Nuclear Information System (INIS)
The report considers experimental and theoretical works on studying the energy spectra of prompt neutrons emitted in spontaneous fission and neutron induced fission of Minor Actinides. It is noted that neutron spectra investigations were done for only a small number of such nuclei, most measurements, except those of Cf-252, having been carried out long ago by obsolete methods and imperfectapparatus. The works have no detailed description of experiments, analysis of errors, detailed numerical information about results of experiments. A conclusion is made that the available data do not come up to modern requirements. It is necessary to make new measurements of fission prompt neutron spectra of transuranium nuclides important for the objectives of working out a conception of minor actinides transmutation by means of special reactors. (author).
1997-03-01
Measurement of #gamma#-ray emission probabilities for "1"0"1Mo
International Nuclear Information System (INIS)
"1"0"1Mo is one of the key nuclides in diagnosing fission burn-up. However, it's difficult to measure its nuclear decay data due to its short half-life. Present study concerns in the measurements of #gamma#-ray emission probabilities, P_#gamma#, of "1"0"1Mo and "1"0"1Tc using the balance of scheme method and the entire process recording. The P_#gamma# of "1"0"1Mo by the entire process recording is about 5% lower than that by using the balance of scheme method. The P_#gamma# of "1"0"1Tc using the two methods agree each other very well. So, it seems the #gamma#-ray emission probabilities as well as measurement method still need study further for "1"0"1Mo. (authors)
2006-07-01
Delayed neutron energy spectra following fast fission of "2"3"8U
International Nuclear Information System (INIS)
Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron ...
Plasma diagnostics by spectra from LHD and atomic data
International Nuclear Information System (INIS)
We have observed EUV spectra from the Large Helical Device (LHD) at the National Institute for Fusion Science (NIFS). We measured spectra of impurity ions; carbon, iron, xenon, tin and tungsten ions. In some cases, the plasma evolution was stable and a steady discharge was obtained, but sometimes the plasma underwent radiation collapse and rapid cooling. For carbon and iron spectra, we studied plasma diagnostics by intensity ratios of spectral lines. For other spectra of higher Z element, xenon, tin and tungsten, we studied mainly on line identifications comparing with theoretical calculations and experimental data. Related atomic data for these researches will be also discussed. (author)
2009-04-01
International Nuclear Information System (INIS)
We measured neutron time-of-flight spectra from 90 MeV protons and 140 MeV alpha particles bombarding thin targets of Al, Ni, Zr, and Bi at laboratory angles between 20_0 and 135_0. The low-energy (5 to 45 MeV) portions of the spectra were measured with 5 cm diameter by 5 cm deep NE-213 counters at 1 m flight paths with n-#betta# pulse-shape discrimination. The high-energy (35 to 150 MeV) portions of the spectra were measured with 12.7 cm diameter by 10.2 cm deep NE-102 counters at flight paths of 2.0 to 5.0 m. The proton-induced measured neutron spectra reveal three distinct energy regions: a low-energy evaporation region, a high-energy region dominated by the quasifree scattering process, and an intermediate-energy region dominated by multistep, preequilibrium processes. In the latter two regions, the ...
EPR investigation of some irradiated traditional oriental spices
International Nuclear Information System (INIS)
The X-band EPR spectra of unirradiated and "6"0 Co gamma ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), saffron (Crocus sativus L., Iridaceae), and curry have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones, most probably due to the presence of semiquinones, previously reported to have paramagnetic properties. After gamma ray irradiation at absorbed dose up to 11.3 kGy we have noticed in all spices the presence of complex EPR spectra consisting of a superposition of at last two different paramagnetic species whose amplitude increase monotonously with the absorbed dose. A 100 deg. C isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that form the initial ...
2005-09-13
Electromagnetic interactions in the {Delta}-resonance region
Energy Technology Data Exchange (ETDEWEB)
Cross sections for some electro- and photoinduced spallation reactions on {sup 27}Al and {sup 51}V are measured in the energy region 130 MeV to 580 MeV with the activation method. Comparisons are made with calculations based on the Dalitz formalism for virtual photon spectra, and Monte Carlo calculations based on a cascade evaporation model, respectively. By use of Bremsstrahlung with end-point energies from threshold to 750 MeV, the yields for photo- production of{pi}{sup -}leading to ground and isomeric states in {sup 197}Hg are measured with the activation method. The activity from the Hg-isotopes were measured after a chemical separation of Hg from the target material. The yields and isomeric ratios are compared with impulse approximation calculations. For the photoproduction of {sup 195m}Hg and {sup 192}Hg from {sup 197}Au, the yields were measured. The experimental mean cross ...
1995-03-01
Gamma-ray spectrometric analysis of nuclides formed in thorium by neutron irradiation
International Nuclear Information System (INIS)
Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).
1985-02-01
Semihard production of neutral pseudoscalar and tensor mesons in photon-photon collisions
Energy Technology Data Exchange (ETDEWEB)
We investigate the semihard production of neutral pseudoscalar and tensor mesons in high-energy [gamma][gamma] collisions (M=P=[pi][sup 0], [eta], [eta]' or M=T=a[sub 2], f[sub 2], f[sub 2]'). We deal with the exclusive [gamma][gamma][yields]MM' or semi-exclusive [gamma][gamma][yields]MX reactions (X is the hadron jet with not too large mass). The considered transfer momenta are small in comparison with the photon energies and they are large in comparison with the confinement scale. The amplitudes of these processes are determined by the odderon exchange, i.e. three-gluon exchange in the lowest order of perturbative QCD. The cross sections are calculated in this approximation. The possibility of measurements at LEP and at future [gamma][gamma] colliders is discussed. (orig.).
1992-12-21
Detector questions for a gamma-gamma collider
Energy Technology Data Exchange (ETDEWEB)
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
1995-02-01
Detector questions for a gamma-gamma collider
International Nuclear Information System (INIS)
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
\\psi(2S) Decays into $\\J$ plus Two Photons
Using $\\gamma \\gamma J/\\psi, J/\\psi \\ra e^+ e^-$ and $\\mu^+ \\mu^-$ events from a sample of $14.0\\times 10^6$ $\\psip$ decays collected with the BESII detector, the branching fractions for $\\psip\\ra \\pi^0\\J$, $\\eta\\J$, and $\\psi(2S)\\ar\\gamma\\chi_{c1},\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi$ are measured to be $B(\\psip\\ra \\pi^0\\J) = (1.43\\pm0.14\\pm0.13)\\times 10^{-3}$, $B(\\psip\\ra \\eta\\J) = (2.98\\pm0.09\\pm0.23)%$, $B(\\psi(2S)\\ar\\gamma\\chi_{c1}\\ar\\gamma\\gamma\\jpsi) = (2.81\\pm0.05\\pm 0.23)%$, and $B(\\psi(2S)\\ar\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi) = (1.62\\pm0.04\\pm 0.12)%$.
2004-01-01
A measurement of the parity-violating gamma-ray asymmetry in the neutron-proton capture
Energy Technology Data Exchange (ETDEWEB)
The {rvec n} + p {yields} d + {gamma} experiment under construction at LANSCE studies the weak interaction between neutrons and protons. The experiments will measure the directional dependence of the parity-violating {gamma}-ray asymmetry, A{sub {gamma}}, in the polarized cold neutron capture by para-hydrogen. The goal is to measure A{sub {gamma}} with uncertainty of 0.5 x 10{sup -8}, 10% of its predicted value. A{sub {gamma}} primarily isolates the {Delta}I = 1 component of the hadronic weak interaction and thus will determine the long-range weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. The experiment is carefully designed for the LANSCE pulsed spallation neutron source to achieve the proposed statistical precision and to control systematic errors. We discuss the experiment and its status.
2002-01-01
Energy Technology Data Exchange (ETDEWEB)
Plutonium-containing compounds vary widely in isotopic content, and as a result, the dose as function of isotopic content also varies considerably. Determination of the dose from neutrons, decay and capture gammas from plutonium in the form of compounds thus requires that the spontaneous fission and ({alpha},n) source and spectra from each individual isotope be known. To facilitate dose calculations from plutonium-containing compounds, we have calculated the spontaneous fission and ({alpha},n) sources and spectra for 1 g of each of the plutonium isotopes in the form of either PuF{sub 4} or PuO{sub 2}. As {sup 241}Am is often a component in a mixture of plutonium isotopic compounds, the source and spectra from 1 g of {sup 241}Am mixed with PuF{sub 4} or PuO{sub 2} has also been determined. Using these results, the neutron source and spectra may be determined for any sample ...
1996-10-01
RF plasma nitriding of severely deformed iron-based alloys
Energy Technology Data Exchange (ETDEWEB)
The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10{sup -5} bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of {epsilon} and {gamma}' nitrides in the compound layer, with a preferential formation of {gamma}' at the ...
2003-05-15
Excitation function of "5"9 Co (n, 2n) "5"8 Co process in the energy range 13.9-14.7 MeV
International Nuclear Information System (INIS)
The objective of the study is to measure the neutron cross sections for the "5"9 Co (n, 2n) "5"8 Co reaction around the 14 MeV energy region. Neutron activation cross section for almost all the nuclei, mostly in the medium energy region e.g., 7 to 20 MeV are reported in literature. Neutron cross section data around 14 MeV is of immense importance for the design of D + T fusion reactors. The accuracy of the cross section data at this energy region is a requirement for correct prediction of reactor parameters e.g., tritium breeding, nuclear heating, induced activity, etc. In order to perform the experiment, the Co-sample sandwiched in Ni foils was irradiated employing the J-25 Neutron Generator at the AERE, Savar, Dhaka. After irradiation, the counting was done by the activation technique using a high resolution Hp Ge gamma ray spectrometer. The gamma ray spectra was analyzed in a Canberra series-40 ...
International Nuclear Information System (INIS)
State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method was developed to permit rapid, accurate ...
1976-01-01
Photoacoustic response to X-ray absorption in copper and brass
Energy Technology Data Exchange (ETDEWEB)
The X-ray photoacoustic spectra of copper and brass (64.7 wt.% Cu and 35.3 wt.% Zn) have been measured at XANES (X-ray absorption near-edge structure) regions using synchrotron radiation. These spectra were compared with optical density of X-ray spectra. It is shown that the information derived from XANES is also included in the X-ray photoacoustic spectrum which reflects the heat production processes in copper and brass. However, the results showed that the increases and changes of the photoacoustic signal were different from those of the X-ray absorption coefficient at XANES regions. (author).
1990-09-01
Direct interactions in neutron inelastic scattering spectra
International Nuclear Information System (INIS)
Inelastically scattered neutron spectra and angular distributions measured for a number of nuclei at the 9.1 and 14.4 MeV incident neutron energies are fitted well as a sum of neutron evaporation spectrum and the direct interaction part. For the last one the practical scheme of parametrization based on direct interaction theory is presented. The relative contribution of direct interactions in double differential cross sections and parameters of neutron evaporation spectra have been evaluated. All results have a simple physical interpretation and may be useful at interpolating of data in a wide energy interval.
1976-07-06
[sup 3]He([ital n],[gamma])[sup 4]He cross section and the photodisintegration of [sup 4]He
Energy Technology Data Exchange (ETDEWEB)
The absolute cross section of the [sup 3]He([ital n],[gamma])[sup 4]He reaction was measured at five energies between [ital E][sub [ital n
1993-11-01
CP Violation with Bs -> J/Psi phi at the Tevatron
Recent results using B_s -> J/Psi phi decays for measuring the CP violating phase, phi_s, and the decay width difference for the two mass eigenstates, Delta Gamma_s, are presented from the CDF and D0 experiments at the Fermilab Tevatron collider.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process {gamma}{gamma}{yields}tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future {gamma}{gamma} colliders for small values of tan {beta}. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)
2000-05-01
International Nuclear Information System (INIS)
We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process #gamma##gamma##->#tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future #gamma##gamma# colliders for small values of tan #beta#. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)
2000-05-01
NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture
Energy Technology Data Exchange (ETDEWEB)
The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, ...
2010-01-01
A calorimetric-time-of-flight (CTOF) technique was used for real-time, high-precision measurement of neutron spectrum at the angle of 175 degrees from the initial proton beam direction, which hits a face plane of a cylindrical iron target of 20 cm in diameter and 25 cm thick. A comparison was performed between the neutron spectra predicted by the MARS and the MCNPX code systems and measured by experiments for 0.4-, 0.6-, 0.8-, 1.0-, and 1.2-GeV protons.
2009-01-01
Unfolding of differential energy spectra in the MAGIC experiment
Energy Technology Data Exchange (ETDEWEB)
The paper describes the different methods, used in the MAGIC experiment, to unfold experimental energy distributions of cosmic ray particles ({gamma}-rays). Questions and problems related to the unfolding are discussed. Various procedures are proposed which can help to make the unfolding robust and reliable. The different methods and procedures are implemented in the MAGIC software and are used in most of the analyses.
2007-12-21
Solution of Bohr's collective Hamiltonian for transitional odd-mass nuclei
International Nuclear Information System (INIS)
A numerically feasible method, based on the use of deformed phonons, is developed for the diagonalization of the collective quadrupole Hamiltonian for a system with an odd particle coupled to an anharmonic even core. Examples: the transition from prolate to oblate via #gamma#-unstable shapes and furthermore the hsub(9/2) spectra of the nuclei "1"8"7Ir and "1"9"7Tl. (Auth.).
5f electron localization in UTX compounds
International Nuclear Information System (INIS)
Bulk electronic properties and photoelectron spectra of UNiAl and UPdSn are discussed in terms of varying degree of the localization of 5f states. For UPdSn with #gamma#=5 mJ/mol K"2, localized 5f states can be expected, but photoemission shows still the presence of 5f states at E_F. (orig.).
Soft X-ray spectra of amorphous hydrogenated silicon
Energy Technology Data Exchange (ETDEWEB)
The Si-L X-ray emission spectrum of amorphous hydrogenated silicon (a-Si:H) is presented and discussed. For a qualitative interpretation of the measured spectra cluster calculations of pure Si clusters (SiSi4) and Si clusters with hydrogen (SiSi3H) have been performed using a simplified LCAO-X scheme. In general the level shifts caused by introduction of hydrogen are small compared with the valence band width.
1985-06-01
International Nuclear Information System (INIS)
An original evaluating method of gain degradation has been found for neutron irradiated transistors. It establishes a correlation between degradation and the product of two coefficients: spectra factor and an electrical parameter which is measured or directly deduced from manufacturer's data. Equivalence for several type of spectra (fission, 14MeV and degradation sensitivity to electrical parameters values of individual components of a batch are obtained.
1974-06-01
On some problems caused by wavelet filtering in calculated spectra
Energy Technology Data Exchange (ETDEWEB)
It is shown that de-noising a measured time signal by wavelet technique produces a rather good result in time domain, while it has unwanted consequences in spectrum estimation. Therefore it can be used for reconstruction of the picture of the physical process, but it should be avoided, when the aim is to reveal eigenfrequencies or transient behaviour of the spectra.
1999-08-01
Cumulative kaon production by 10 GeV protons
International Nuclear Information System (INIS)
The K"+- and K"-meson cumulative production cross sections are measured at 119"0 in the laboratory system on nuclei Be, Al, Cu and Ta bombarded by 10 GeV protons. Spectra of the K"-mesons consisting of only sea quarks show universal features characteristic of the spectra of cumulative particles, which contain valence quarks. Evidence is obtained for the fact that the energy density in a flucton can exceed the mean nuclear density by an order of magnitude.
EPR investigation of some traditional oriental irradiated spices
International Nuclear Information System (INIS)
The 9.50 GHz electron paramagnetic resonance (EPR) spectra of unirradiated and "6"0Co #gamma#-ray irradiated cardamom (Elettaria cardamomum L. Maton, Zingiberaceae), ginger ((Zingiber officinale Rosc., Zingiberaceae), and saffron (Crocus sativus L., Iridaceae) have been investigated at room temperature. All unirradiated spices presented a weak resonance line with g-factors around free-electron ones. After #gamma#-ray irradiation at an absorbed dose of up to 11.3 kGy, the presence of EPR spectra whose amplitude increase monotonously with the absorbed dose has been noticed with all spices. A 100 "oC isothermal annealing of 11.3 kGy irradiated samples has shown a differential reduction of amplitude of various components that compose initial spectra, but even after 3.6 h of thermal treatment, the remaining amplitude represents no less then 30% of the initial ones. The same peculiarities ...
2007-06-01
Systematic view of optical absorption spectra in the actinide series
International Nuclear Information System (INIS)
In recent years sufficient new spectra of actinides in their numerous valence states have been measured to encourage a broader scale analysis effort than was attempted in the past. Theoretical modelling in terms of effective operators has also undergone development. Well established electronic structure parameters for the trivalent actinides are being used as a basis for estimating parameters in other valence states and relationships to atomic spectra are being extended. Recent contributions to our understanding of the spectra of 4+ actinides have been particularly revealing and supportive of a developing general effort to progress beyond a preoccupation with modelling structure to consideration of the much broader area of structure-bonding relationships. We summarize here both the developments in modelling electronic structure and the interpretation of apparent trends in bonding. 60 refs., 9 figs., 1 ...
1985-09-01
Systematic view of optical absorption spectra in the actinide series
Energy Technology Data Exchange (ETDEWEB)
In recent years sufficient new spectra of actinides in their numerous valence states have been measured to encourage a broader scale analysis effort than was attempted in the past. Theoretical modelling in terms of effective operators has also undergone development. Well established electronic structure parameters for the trivalent actinides are being used as a basis for estimating parameters in other valence states and relationships to atomic spectra are being extended. Recent contributions to our understanding of the spectra of 4+ actinides have been particularly revealing and supportive of a developing general effort to progress beyond a preoccupation with modelling structure to consideration of the much broader area of structure-bonding relationships. We summarize here both the developments in modelling electronic structure and the interpretation of apparent trends in bonding. 60 refs., 9 figs., 1 ...
1985-01-01
Characteristics of infrared-stimulated luminescence from a feldspar at low temperatures
International Nuclear Information System (INIS)
The characteristics of infrared-stimulated luminescence (IRSL) from a sample of potassium feldspar at low temperatures are presented. These studies extend the previous work from this laboratory on the optical bleaching characteristics and emission spectra of feldspars at room temperature and recent measurements of the stimulated spectrum for a sample of potassium feldspar at room temperature. Stimulation spectra have been measured at 290, 160 and 145 K. By fitting Gaussian functions to the spectra, the peak position is shown to shift to higher photon energies at lower temperatures and the full-width half-maximum of the peak to reduce with decreasing temperature. The variation of IRSL intensity with temperature for several stimulating wavelengths has been determined and the form of the IRSL decay curve measured at 290 and 160 K. No substantial differences were ...
1993-07-01
FFTF reactor-characterization program: gamma-ray measurements and shield characterization
A series of experiments is to be made during the acceptance test program of the Fast Flux Test Facility (FFTF) to measure the gamma ray characteristics of the Fast Test Reactor (FTR) and to establish the performance characteristics of the reactor shield. These measurements are a part of the FFTF Reactor Characterization Program (RCP). Detailed plans have been developed for these experiments. During the initial phase of the Characteristics Program, which will be carried out in the In-Reactor Thimble (IRT), both active and passive measurement methods will be employed to obtain as much information concerning the gamma ray environment as is practical. More limited active gamma ray measurements also will be made in the Vibration Open Test Assembly (VOTA).
Energy Technology Data Exchange (ETDEWEB)
The effects of group structures and weighting functions on neutron penetration through a thick Na-Fe geometry are studied. The recommended broad-group (61-neutron/23-gamma-ray) and few-group (22-neutron/10-gamma-ray) structures are tailored to the sodium and iron resonances, windows, and capture gamma-ray spectra. The best weighting functions are shown to be fine-group fluxes selected from a few key locations in the geometry. These group structures and weighting functions, relative to existing group structures and conventional weighting functions, improve the accuracy of the computed 61-neutron-group Bonner ball responses by up to one hundred percent and of the computed 22-neutron-group results by up to six hundred percent.
1987-01-01
Cross-section libraries and analysis of fast reactor benchmarks
International Nuclear Information System (INIS)
Using indigenously developed computer program, coupled neutron gamma multi-group libraries have been generated from MA TXS-NJOY files. The MATXS format contains all the details for each reaction. Temperature and dilution factor dependent cross-sections have been generated and used in discrete ordinates method for benchmark studies of fast critical experiments. We have analyzed criticality benchmarks, which includes CSEWG fast critical benchmarks, "2"3"3U and Pu spheres and enriched uranium spheres using 30-group neutron cross-sections. Neutron and gamma spectra for spheres with point neutron source at the center, are also calculated with 42-group coupled neutron gamma cross-sections. (author)
2005-11-01
Energy Technology Data Exchange (ETDEWEB)
Neutron time-of flight spectra were measured from 90 MeV protons and 140 MeV alpha-particle bombardment of Al, Ni, Zr, and Bi at laboratory angles between 20/sup 0/ and 130/sup 0/. The proton induced neutron spectra reveal three distinct energy regions; a low energy evaporation region, a high-energy region dominated by quasi-free scattering processes and an intermediate-energy region dominated by multi-step, pre-equilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-induced neutron spectra show these same distinct energy regions plus an exponential fall-off above the beam energy per nucleon. The high-energy portions of the forward-angle neutron and proton cross sections are in ratios consistent with the assumption that single nucleon-nucleon scattering dominates. For heavy-mass targets, the low-energy evaporation regions show neutron ...
1982-01-01
International Nuclear Information System (INIS)
Neutron time-of flight spectra were measured from 90 MeV protons and 140 MeV alpha-particle bombardment of Al, Ni, Zr, and Bi at laboratory angles between 20"0 and 130"0. The proton induced neutron spectra reveal three distinct energy regions; a low energy evaporation region, a high-energy region dominated by quasi-free scattering processes and an intermediate-energy region dominated by multi-step, pre-equilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-induced neutron spectra show these same distinct energy regions plus an exponential fall-off above the beam energy per nucleon. The high-energy portions of the forward-angle neutron and proton cross sections are in ratios consistent with the assumption that single nucleon-nucleon scattering dominates. For heavy-mass targets, the low-energy evaporation regions show neutron yields ...
Probes of Diffusive Shock Acceleration using Gamma-Ray Burst Prompt Emission
The principal paradigm for gamma-ray bursts (GRBs) suggests that the prompt transient gamma-ray signal arises from multiple shocks internal to the relativistic expansion. This paper explores how GRB prompt emission spectra can constrain electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The array of possible high-energy power-law indices in accelerated populations is highlighted, focusing on how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. When encompassing the MeV-band spectral break, fits to BATSE/EGRET burst data indicate that the preponderance of electrons responsible for the prompt emission reside in an intrinsically non-thermal population. This differs markedly from typical populations generated in acceleration simulations; potential resolutions of this ...
2009-01-01
International Nuclear Information System (INIS)
Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.
Estimation of gamma-absorption method for measurement of layers thickness in multi-layers articles
International Nuclear Information System (INIS)
Certain problems of gamma-absorption method of measuring the thickness of layers in multi-layer items are analyzed. Two examples of solving the above-mentioned problems have been considered. One of them deals with a two-layer item, its integral thickness being known or measured in advance, the second example is referred to a two-layer item with unknown integral value
Search for anisotropy in the L x-gamma angular correlations following the decay of "2"0"7Bi
International Nuclear Information System (INIS)
An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).
International Nuclear Information System (INIS)
The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.
1989-09-10
Extraction of Kaon Formfactors from K->mu nu gamma Decay at ISTRA+ Setup
The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).
2010-01-01
Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station
International Nuclear Information System (INIS)
This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.
Effect of X- and gamma-rays on phenolic compounds from Maytenus aquifolium Martius
International Nuclear Information System (INIS)
The effect of irradiation using several doses of X- and #gamma#-rays (10, 20, 40, 60, 80 and 100 kGy), upon total phenolic compounds contained in the leaves of Maytenus aquifolium Martius (Celastraceae) 'espinheira santa', was investigated. The content of phenolic compounds (measured by the Folin-Denis spectrophotometric method) was unaffected by X- or #gamma#-ray irradiation, at any dose. (author)
2005-06-01
Measurement of gamma-ray detection efficiency in irradiated materials examination facility
Energy Technology Data Exchange (ETDEWEB)
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute ...
2001-05-01
Neutron and gamma-ray penetrations in thick iron
Energy Technology Data Exchange (ETDEWEB)
Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron ...
1980-03-01
Energy Technology Data Exchange (ETDEWEB)
A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10/sup 0/ with primary energies between 200 eV and 15 keV. The energy resolution ..delta..E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H/sub 2//sup +/ and 4430 eV N/sub 2//sup +/ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths.
1984-03-01
International Nuclear Information System (INIS)
A time-of-flight mass spectrometer has been constructed to measure the energy spectra of particles scattered by 10"0 with primary energies between 200 eV and 15 keV. The energy resolution #DELTA#E/E of the system is between 0.1 and 0.4%. Energy spectra of scattered molecules and their dissociation products are shown for 570 eV H_2"+ and 4430 eV N_2"+ as projectiles. Electron capture into unbound states of the neutral molecule, with perhaps some contribution from mutual scattering within the molecule, appears to explain the observed dissociation product energy spectra peak widths. (orig.).
Atmospheric proton and deuterium energy spectra determination with the MASS2 experiment
Energy Technology Data Exchange (ETDEWEB)
The energy spectra of atmospheric-secondary protons and deuterium nuclei have been measured during the September 23, 1991, balloon flight of the NMSU/Wizard - MASS2 instrument. The apparatus was launched from Fort Sumner, New Mexico. The geomagnetic cutoff at the launch site is about 4.5 GV/c. The instrument was flown for 9.8 hours at an altitude of over 100,000 feet. Particles detected below the geomagnetic cutoff have been produced mainly by the interactions of the primary cosmic rays with the atmosphere. The measurement of cosmic ray energy spectra below the geomagnetic cutoff provide direct insights into the particle production mechanism and allows comparison to atmospheric cascade calculations.
1995-09-01
/sup 90,91/Zr (n,#alpha#) /sup 87,88/Sr reactions at 14.3 and 18.15 MeV incident neutron energy
International Nuclear Information System (INIS)
Measurements of alpha spectra in the (n, #alpha#) reactions induced on /sup 90,91/Zr at 14.3 and 18.15 MeV incident neutron energy are presented. A microscopic calculation of these spectra has been made using both pick-up and knock-on theories, and in both cases only one overall normalizing factor, which is the same for the two target nuclei and incident energies and all the considered transitions, appears as a free parameter in the calculation. Pick-up calculations provide a very satisfactory reproduction of the data. Knock-on calculations reproduce many qualitative features of the measured spectra, but do not allow a fully satisfactory reproduction of them. While the results obtained do not exclude knock-on contributions to these reactions, their presence is not established.
The supersymmetric quantum effects at {gamma}{gamma} colliders
Energy Technology Data Exchange (ETDEWEB)
We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at {gamma}{gamma} colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R{sub p}-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)
2001-08-01
The supersymmetric quantum effects at #gamma##gamma# colliders
International Nuclear Information System (INIS)
We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at #gamma##gamma# colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R_p-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)
2001-08-01
Energy Technology Data Exchange (ETDEWEB)
Both solvent extraction and spectrophotometric techniques were used to show the alterations that gamma radiation causes in the behavior of tetracycline molecule as far as its extracting and complexing power are concerned. The effect of gamma radiation on the solid tetracycline molecule, benzyl alcohol and on the solution of both was examined in solvent extraction systems whose aqueous phases were made up by {sup 152} Eu-{sup 154}Eu radioactive tracer solutions and whose organic phases were constituted by tetracycline-benzyl alcohol solutions. Experiments were performed in order to determine whether or not the water used for the pre-saturation of benzyl alcohol would influence the radiolysis of tetracycline. Solvent extraction and spectrophotometry were the techniques used to obtain the necessary data. Absorption spectra of irradiated tetracycline benzyl alcohol solutions submitted to several gamma ...
1982-07-01
The Use of Weighting in Periodicity Searches in All-Sky Monitor Data: Applications to the GLAST LAT
Energy Technology Data Exchange (ETDEWEB)
The light curves produced by all-sky monitors, such as the Rossi X-ray Timing Explorer All-Sky Monitor and the Swift Burst Alert Telescope (BAT), generally have non-uniform error bars. In searching for periodic modulation in this type of data using power spectra it can be important to use appropriate weighting of data points to achieve the best sensitivity. It was recently demonstrated that for Swift BAT data a simple weighting scheme can actually sometimes reduce the sensitivity of the power spectrum depending on source brightness. Instead, a modified weighting scheme, based on the Cochran semi-weighted mean, gives improved results independent of source brightness. We investigate the benefits of weighting power spectra in period searches using simulated GLAST LAT observations of {gamma}-ray binaries.
2009-06-25
High Magnetic Field NMR Studies of LiVGe$_2$O$_6$, a quasi 1-D Spin $S = 1$ System
We report $^{7}$Li pulsed NMR measurements in polycrystalline and single crystal samples of the quasi one-dimensional S=1 antiferromagnet LiVGe$_2$O$_6$, whose AF transition temperature is $T_{\\text{N}}\\simeq 24.5$ K. The field ($B_0$) and temperature ($T$) ranges covered were 9-44.5 T and 1.7-300 K respectively. The measurements included NMR spectra, the spin-lattice relaxation rate ($T_1^{-1}$), and the spin-phase relaxation rate ($T_2^{-1}$), often as a function of the orientation of the field relative to the crystal axes. The spectra indicate an AF magnetic structure consistent with that obtained from neutron diffraction measurements, but with the moments aligned parallel to the c-axis. The spectra also provide the $T$-dependence of the AF order parameter and show that the transition is either second order or weakly first order. Both the ...
2001-01-01
Higgs, SUSY and the standard model at {gamma}{gamma} colliders
Energy Technology Data Exchange (ETDEWEB)
In this report, I surveyed physics potential of the {gamma}{gamma} option of a linear e{sup +}e{sup -} collider with the following questions in mind: What new discovery can be expected at a {gamma}{gamma} collider in addition to what will be learned at its 'parent' e{sup +}e{sup -} linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e{sup -} beams, we find that a {gamma}{gamma} collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e{sup -}e{sup -} system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a {gamma}{gamma} collider. CP property ...
2001-10-11
Higgs, SUSY and the standard model at #gamma##gamma# colliders
International Nuclear Information System (INIS)
In this report, I surveyed physics potential of the #gamma##gamma# option of a linear e"+e"- collider with the following questions in mind: What new discovery can be expected at a #gamma##gamma# collider in addition to what will be learned at its 'parent' e"+e"- linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e"- beams, we find that a #gamma##gamma# collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e"-e"- system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a #gamma##gamma# collider. CP property of the scalar sector can be explored in detail by ...
2001-10-11
Measurement of the photon-proton total cross section at a center-of-mass energy of 209 GeV at HERA
Energy Technology Data Exchange (ETDEWEB)
The photon-proton total cross section has been measured in the process e{sup +}p{yields}e{sup +}{gamma}p{yields}e{sup +}X with the ZEUS detector at HERA. Events were collected with photon virtuality Q{sup 2}<0.02 GeV{sup 2} and average {gamma}p center-of-mass energy W{sub {gamma}}{sub p}=209 GeV in a dedicated run, designed to control systematic effects, with an integrated luminosity of 49 nb{sup -1}. The measured total cross section is {sigma}{sub tot}{sup {gamma}}{sup p}=174{+-}1 (stat.){+-}13 (syst.) {mu}b. The energy dependence of the cross section is compatible with parameterizations of high-energy pp and pp-bar data.
2002-04-15
International Nuclear Information System (INIS)
Theoretical interpretation of fast-charged-particle spectra, observed in the #alpha#-particle-induced reactions on the s-d shell nuclei (A = 24-28), in terms of the Intranuclear Cascade Model and the GDH exciton model (ALICE) is presented. The de-excitation of the excited residual nuclei is accounted for by the evaporation process. The theoretically predicted fast-proton and #alpha#' spectral shapes compare reasonably well with the corresponding measured spectra. However, the magnitude depends critically (as expected) on the reaction cross section employed by the model. As a first step to improve the model predictability of the reaction products, a closer look at the calculation of the #alpha#-particle reaction cross sections was undertaken. A microscopic approach using the optical theorem of Glauber's theory was employed to estimate the #alpha#-induced reaction cross sections for the light target nuclei under ...
Thyroidal uptake of iodine-123 in children using a gamma camera and computer
Energy Technology Data Exchange (ETDEWEB)
The measurement of thyroidal uptake of radioiodine using a gamma camera and computer is described. In 12 children there was good agreement with simultaneous measurements using a probe, while in a further 14 patients the uptake values were consistent with the clinical diagnosis. The technique should be especially useful for infants and small children.
1985-10-01
Radon and radon daughter evaluation in a natural radioactivity survey indoors
Energy Technology Data Exchange (ETDEWEB)
An indoor survey in order to estimate the population exposure in five towns of an Italian Region is presented. A particular methodology for the campaign was planned and is being applied. Gamma spectrometry of building materials, exposure rate measurements indoors and outdoors and radon concentration measurements indoors were taken with different techniques. A correlation was found between mean gamma exposure rate and mean radon concentration in the houses investigated. An evaluation of mean effective dose equivalents for the inhabitants of the five towns is reported.
1985-10-01
Gamma absorption determination of concentration in a three-component mixture
International Nuclear Information System (INIS)
A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.
Determining the upper limit of Gamma_{ee} for the Y(4260)
By fitting the R values between 3.7 and 5.0 GeV measured by the BES collaboration, the upper limit of the electron width of the newly discovered resonance Y(4260) is determined to be 240 eV at 90% C.L., together with the BABAR measurement on the product of Gamma_{ee} and BR(Y(4260) --> pi+pi- J/psi), this implies a large decay width of Y(4260) --> pi+pi- J/psi final states.
2006-01-01
International Nuclear Information System (INIS)
A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.
Semileptonic b to u transition
Experimental studies of charmless semileptonic B decays can be broadly categorized into inclusive and exclusive measurements depending on how the final states are treated. The inclusive method measures the decay rate $\\Gamma(B \\to X_u \\ell \
2007-01-01
Neutron induced reaction cross-sections of iron in the energy range 1 to 20 MeV: A work programme
International Nuclear Information System (INIS)
Iron is one of the main constituents of stainless steel which is used as a structural material in nuclear reactors. In fast and conceptual fusion and fusion-fission hybrid systems the primary energy range of neutron interaction lies between 1 and 20 MeV which opens up several reaction channels. The reaction cross-sections in this energy range are important for dosimetry, radiation damage, neutronics and safety studies of nuclear reactors. Keeping this in view Nuclear Data Section of the International Atomic Energy Agency has sponsored a Research Co-ordination Programme on Methods for the Calculation of Fast Neutron Nuclear Data for Structural Elements. Under this programme we propose to study (n,n'), (n,2n), (n,3n), (n,p), (n,np), (n,pn), (n,#alpha#), (n,n#alpha#), (n,#alpha#n) and (n,#gamma#) reaction cross-sections. Besides these, total, elastic and discrete level inelastic scattering cross-sections, angular distributions of neutron production cross-sections, ...
1988-01-01
FFTF operational results: startup to 100 MWd/kg
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a 400-MW(t) sodium-cooled fast reactor operating at the Hanford Engineering Development Laboratory in Richland, Washington, to conduct fuels and materials testing in support of the US liquid-metal fast breeder reactor program. Startup and initial power testing included a comprehensive series of nuclear and nonnuclear tests to verify the thermal and neutronic characteristics of the plant and to demonstrate its inherent safety features. Extensive reactor core characterization measurements were completed to provide the neutron and gamma spectra, fission rates, and other physics data needed to design and evaluate tests irradiated in the FFTF. A specially designed series of natural-circulation tests was performed to demonstrate the inherent safety features of the plant. Early in 1982 the FFTF began its first 100-d irradiation cycle. Since that time the plant has operated beyond expectations; ...
Energy Technology Data Exchange (ETDEWEB)
In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite ...
1985-12-01
Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel
International Nuclear Information System (INIS)
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning ...
2009-03-01
Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel
Energy Technology Data Exchange (ETDEWEB)
In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the gamma scanning ...
2007-06-15
Forthcoming (n, #gamma#) measurements on the Fe and Ni isotopes at CERN n_TOF
International Nuclear Information System (INIS)
An overview of the past, present and future research activities at the CERN neutron time of flight facility n_TOF is given, with special focus on the astrophysical aspects. During the first campaign (Phase I), neutron capture cross sections of relevance for several aspects of the s-process nucleosynthesis have been measured. A second campaign has recently started (Phase II), aiming at the study of the weak s-process component via accurate (n,#gamma#) measurements of the Fe and Ni isotopes. Some changes in the facility will allow us to perform these measurements with improved experimental conditions.
2010-01-01
RESUME-95: Results of an International Field Test of Mobile Equipment for Emergency Response
DEFF Research Database (Denmark)
In 1995 the exercise RESUME-95 (Rapid Environmental Surveying Using Mobile Equipment) took place in Finland. Groups from 8 European countries joined the exercise. The methods used were airborne gamma-ray measurements, car-borne measurements and in situ stationary measurements. The results of the measurements are analyses aiming at disclosing similarities and differences between groups and measuring techniques.
1997-01-01
Using Gamma-Ray Burst Prompt Emission to Probe Relativistic Shock Acceleration
It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the significant range of spectral ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
The X-ray spectra of {approx}200 AGN collected from Swift-BAT were analyzed to test the Unified Model for AGN. Specifically, the photon indices, high energy cutoffs, and reflection components of Sy1 and Sy2 were compared. Under the Unified Model, the photon indices and reflection components for Sy1 should be larger than Sy2 and the high energy cutoffs should be the same. Fitting a simple power law model to the sample spectra proved to be insufficient. The PEXRAV model fit the spectra of the Sy1 and Sy2 significantly better, indicating that a reflection component and/or high energy cutoff exists as the Unified Model expects. Using both the simple power law and PEXRAV models it was concluded that in the population studied, Sy1 had a larger photon index than Sy2, as expected by the Unified Model. For Sy1 and Sy2, the reflection components were found to be compatible, but given the large errors, this finding cannot be said to ...
2010-08-25
International Nuclear Information System (INIS)
InP-quantum dots (QDs) are promising sources of single-photons and as active laser medium, emitting in the red part of the visible spectrum and thus in the range of the highest sensitivity of current silicon detectors. The self assembled QDs were grown by metal organic vapor phase epitaxy and are embedded in between distributed Bragg reflectors (DBRs), afterwards the sample was processed by a Focused Ion Beam to fabricate micro-pillars. The DBRs and the high refractive index step between pillar and air results in a three dimensional mode confinement and highly directed emission and thus higher intensity. We have investigated the mode spectra by micro-photoluminescence measurements for different pillar diameters and compared the spectra with a theoretical model showing up good consistency. Q-factors up to 3600 were achieved.
2009-03-22
Moessbauer spectroscopic determination of chemical state of iron in bauxite
International Nuclear Information System (INIS)
The chemical state of iron contained in several kinds of bauxite, which are utilized as a raw material in the aluminum industry in Japan, were investigated by Moessbauer spectroscopy. The main compounds of iron were identified from the results, which showed variations of the Moessbauer absorption spectra with calcination and measuring temperature. Although the absorption intensities of the spectra differed significantly, major species identified were paramagnetic or superparamagnetic #alpha#-Fe_2O_3 in all of these bauxite samples. The superparamagnetic #alpha#-Fe_2O_3 was found mainly in the gibbsite-type bauxite, but not in the boehmite/gibbsite-type or the boehmite-type bauxite. The Moessbauer absorption spectra of red mud and its calcined products were also given. (author).
K-edge X-ray absorption spectra of argon in sputtered aluminum films
International Nuclear Information System (INIS)
We have measured K-edge X-ray absorption spectra of argon in sputtered aluminum films at a synchrotron radiation facility (the Photon Factory). We found that the energy and shape of white line change when the film is annealed at 500 C and the spectrum becomes resembling that of argon implanted in silicon. From the analyses of the X-ray absorption spectra and TEM observation we concluded that argon exists as very small atom clusters with a diameter less than 1 nm or exist as isolated atoms in the as-sputtered aluminum film, and that the size of the clusters become as big as 10 nm diameter when the film is heated. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)
1999-01-04
Study of d+#ALPHA# system in kinematically complete experiment at 27,2 MeV #alpha#-particle energy
International Nuclear Information System (INIS)
The "2H(#alpha#,p#alpha#)n reaction was investigated in a kinematically complete experiment with a #alpha#-beam at energy 27.2 MeV.The "5He excited state was observed and its parameters were determinate.Coincidence spectra were fitted by contribution of sequential decay through the "5He ground and excited states.The best agreement with the data was obtained assuming the following "5He excited state parameters: E_a_n=2.8 MeV #GAMMA#=2.5 MeV.
International Nuclear Information System (INIS)
The absorption, emission and magnetic circular dichroism spectra of the anionic complex (Cp_3Pr. NCS)"- were measured at room and low temperatures. On the basis of these spectra the electronic structure in the f-f range could be derived. The parameters of an empirical Hamiltonian were fitted to the experimentally determined crystal field splitting pattern. Compared with the previously examined neutral Cp_3 Pr.X complexes the quadratic crystal field parameter B_0"2 is considerably reduced.
International Nuclear Information System (INIS)
A few metal complexes of isatin-isonicotinoylhydrazone with Ni(II), Cr(III), Co(II), Cu(II), Zn(II) and Cd(II) have been prepared and characterized on the basis of elemental analyses, infrared and electronic spectra as well as "1H NMR spectra, conductivity and magnetic measurements. In view of the results obtained, it has been found that two molecules of isatin-isonicotinoylhydrazone are chelated to the central metal ion as bis-uninegative ONO tridentate ligand forming non-electrolytic octahedral metal complexes. (author)
1997-03-01
Spectra of positrons and electrons emitted in "8"8Y decay
International Nuclear Information System (INIS)
The "8"8Y decay has been studied with the aim to discover emission of monohromatic positrons (MP). The "8"8Sr(d,2N) reaction was used for production of "8"8Y (#beta#"+, Tsub(1/2)=106.6 days) nuclides. The prismatic beta spectrometer has been used to measure spectra of electrons and positrons. No MPs have been found. The resulting upper bound for their emission rate turned out to be lower than theoretically expected one.
Energy Technology Data Exchange (ETDEWEB)
In the reaction sup(nat)Ag + /sup 40/Ar (285 MeV) there have been measured the energy spectra of the isotopes of elements from H to Cl at an emission angle of 40/sup 0/, the energy spectra and angular distributions of /sup 1/H, /sup 2/H, /sup 3/H, and /sup 4/He, and the angular distributions of Li, Be, B, and C. The contribution from multinucleon transfer reactions to the formation of light charged particles is discussed.
1981-11-01
Energy Levels of Phosphorus, P I through P XV
Energy level data are given for the atom and all positive ions of phosphorus (Z = 15). These data have been critically compiled, mainly from published and unpublished material on measurements and analyses of the optical spectra. We have derived or recalculated the levels for a number of the ions. In addition to the level values in cm/sup -1/ and the parity, the J value and the configuration and term assignments are listed if known. Leading percentages from the calculated eigenvectors are tabulated or quoted wherever available. Ionization energies are given for all spectra.
1985-07-01
International Nuclear Information System (INIS)
The #gamma# rays following the #beta# decays of "8"8Kr and "8"8Rb have been studied, using both large volume Ge(Li) detectors for singles and coincidence measurements and anti-Compton spectrometry for singles measurements. Level schemes for "8"8Rb and "8"8Sr were constructed from the data and 74 of 81 #gamma# rays observed in the decay of "8"8Kr were placed in the "8"8Rb level scheme with 23 excited states. For the decay of "8"8Rb, all of the observed 27 #gamma# rays have been placed in the (well known) level structure of "8"8Sr. Spin and parity assignments have been deduced from #beta#-decay logft values and #gamma#-ray transition patterns. Possible shell model interpretations are presented for the level schemes.
Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning
International Nuclear Information System (INIS)
The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).
Study on dose distribution of therapeutic proton beams with prompt gamma measurement
Energy Technology Data Exchange (ETDEWEB)
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The ...
2007-03-15
Energy Technology Data Exchange (ETDEWEB)
This document deals with the couplings between the W boson and Z and gamma particles. WWZ and WW{gamma} vertex are predicted by the electroweak theory based on the symmetry group SU(2){sub L}*U(1){sub Y}, their existence is confirmed by the measurement of the production cross-section of W pairs at LEP. The effective values of the couplings are modified by the introduction of standard model particle loops at the vertex level, the impact on the coupling value is assessed to reach 10{sup -3}. These loops can also include beyond-the-standard-model particles, their impact is in the magnitude order of 10{sup -3} for most models. The fully description of these loops requires the values of 14 complex parameters whose measurement will give information about the existence of new particles. Nevertheless the number of events at LEP is not sufficient to measure all the parameters simultaneously. ...
2005-03-15
Burnup determination of spent nuclear fuel in the pool
Energy Technology Data Exchange (ETDEWEB)
A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in ...
1998-06-01
International Nuclear Information System (INIS)
For 12C 9Be interactions at a kinetic beam energy of 3.2 GeV per nucleon, the spectra of photons at laboratory angles in the range 55o-73o were measured off the kinematical region available to the interaction of single nucleons within colliding nuclei. The use of a fast trigger for selecting events involving the production of high-transverse-momentum photons made it possible to measure spectra off the kinematical boundary of four-nucleon interaction. It is shown that the proposed procedure is adequate to the problem of searches for and investigation of flucton-flucton interaction. In the kinematical region where flucton-flucton interaction can manifest itself, the cross sections in question are on the same order of magnitude as respective model predictions. In order to draw definitive conclusions on the role of flucton-flucton interaction, it is highly desirable to extend the angular range of the ...
2008-11-01
Inf-convolution of g_\\Gamma-solution and its applications
A risk-neutral method is always used to price and hedge contingent claims in complete market, but another method based on utility maximization or risk minimization is wildly used in more general case. One can find all kinds of special risk measure in literature. In this paper, instead of using market modified risk measure, we use a kind of risk measure induced by g_\\Gamma-solution or the minimal solution of a Constrained Backward Stochastic Differential Equation (CBSDE) directly when constraints on wealth and portfolio process comes to our consideration. Such g_\\Gamma-solution and the risk measure generated by it is well defined on appropriate space under suitable conditions. We adopt the inf-convolution of convex risk measures to solve some optimization problem. A dynamic version risk measures defined through ...
2011-01-01
Kaluza-Klein Effects on Higgs Physics in Universal Extra Dimensions
Energy Technology Data Exchange (ETDEWEB)
We examine the virtual effects of Kaluza-Klein (KK) states on Higgs physics in universal extra dimension models. We study the partial widths {Lambda}{sub h{yields}gg}, {Lambda}{sub h{yields}{gamma}{gamma}}, and {Lambda}{sub h{yields}{gamma}Z}, which are relevant for Higgs production and detection in future collider experiments. These interactions occur at one loop in the Standard Model, as do the KK contributions. We find that the deviations induced by the KK exchanges can be significant; for one extra dimension, the gg {yields} h production rate is increased by 10% - 85% for the mass of the first KK state in the range 500 {approx}> m{sub 1} {approx}> 1500 GeV, a region untested by current direct search and precision measurement constraints. The h {yields} {gamma}{gamma} decay width is decreased by {approx}< 20% in the same mass range. For two or more universal extra dimensions the ...
2002-04-05
Energy Technology Data Exchange (ETDEWEB)
Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from ...
2004-12-15
Energy Technology Data Exchange (ETDEWEB)
Diffuse {gamma}-ray emission produced by the interaction of cosmic-ray particles with matter and radiation in the Galaxy can be used to probe the distribution of cosmic rays and their sources in different regions of the Galaxy. With its large field of view and long observation time, the Milagro Gamma Ray Observatory is an ideal instrument for surveying large regions of the Northern Hemisphere sky and for detecting diffuse {gamma}-ray emission at very high energies. Here, the spatial distribution and the flux of the diffuse {gamma}-ray emission in the TeV energy range with a median energy of 15 TeV for Galactic longitudes between 30{sup o} and 110{sup o} and between 136{sup o} and 216{sup o} and for Galactic latitudes between -10{sup o} and 10{sup o} are determined. The measured fluxes are consistent with predictions of the GALPROP model everywhere except for the Cygnus region (l ...
2008-05-14
Tritium monitor with improved gamma-ray discrimination
Energy Technology Data Exchange (ETDEWEB)
Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.
1985-01-01
Parity nonconservation in "2"0"7Pb
International Nuclear Information System (INIS)
Two experiments are currently underway to measure the single-particle weak mixing matrix element for the 1064 KeV transition in "2"0"7Pb. One experiment measures the circular polarization of the 1064 KeV gamma ray emitted from an unpolarized source, while the other experiment measures the forward-backward asymmetry of gamma rays emitted from a polarized source. Analysis of the first set of polarized source data yields an upper limit of 46 eV for the single-particle weak mixing matrix element. copyright 1995 American Institute of Physics.
International Nuclear Information System (INIS)
Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage
International Nuclear Information System (INIS)
Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)
1999-10-26
Investigation of the "1"0"1Mo level and gamma-decay scheme by thermal neutron capture in "1"0"0Mo
International Nuclear Information System (INIS)
The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).
1975-03-01
Measurement of liquid nitrogen level by radiation
Energy Technology Data Exchange (ETDEWEB)
The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)
1995-07-01
Measurement of the parity violating asymmetry A{sub {gamma}} in n{yields}+p{yields}d+{gamma}
Energy Technology Data Exchange (ETDEWEB)
The weak interaction between neutrons and protons has never been resolved experimentally. In analogy with the strong NN interaction, the weak NN interaction at low energy can be parametrized in terms of a meson exchange model with parity violating meson-nucleon couplings. Unlike the measured proton-proton weak interaction, the neutron-proton weak interaction is sensitive to the weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. This coupling, which is responsible for the longest-ranged part of the weak NN interaction and is therefore an essential part of any description of weak interactions in nuclei, remains undetermined despite many years of effort. A measurement of the gamma ray directional asymmetry A{sub {gamma}} in the capture of polarized neutrons by parahydrogen has been proposed at Los Alamos National Laboratory. The goal of this experiment is to determine A{sub ...
2000-02-11
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
International Nuclear Information System (INIS)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning ...
Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel
Energy Technology Data Exchange (ETDEWEB)
In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the gamma-scanning ...
2007-03-15
Production of three vector bosons in #gamma# #gamma# colliders
International Nuclear Information System (INIS)
The production of three vector bosons in #gamma# #gamma# collisions studying the reactions #gamma# + #gamma# #-># W"+ + W"- + Z"0 and #gamma# + #gamma# #-># W"+ + W"- + #gamma#. 12 refs., 4 figs., 2 tabs.
International Nuclear Information System (INIS)
Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.
Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV
International Nuclear Information System (INIS)
The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.
International Nuclear Information System (INIS)
The distribution of mass, charge and angular momentum transfer among the products of 54-Fe (255 MeV) ions collisions with the 106 Cd target have been studied. The energy level schemes for 92-Mo, 60-Ni, 96-Ru and 56-Fe are presented. The production yields of different isotopes were also measured. 1 ref., 14 figs.
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
Ratio of the fissile isomers and prompt fissions yields has been measured in processes of neutron capture by /sup 241/Am and /sup 243/Am nuclei in the neutron energy interval from 0.2 up to 1.3 MeV. The present data and the previous results suggest that the fission Am isomers are spin structure isomers rather than shape isomers.
1984-11-01
Decay scheme data for [sup 101]Mo and [sup 101]Tc
Energy Technology Data Exchange (ETDEWEB)
New measurements of relative gamma-ray emission probabilities in the decay of [sup 101]Mo and [sup 101]Tc are reported. Previously published conversion-electron data have been used along with the gamma-ray data to formulate self-consistent decay schemes. (orig.)
1993-10-01
Decay scheme data for "1"0"1Mo and "1"0"1Tc
International Nuclear Information System (INIS)
New measurements of relative gamma-ray emission probabilities in the decay of "1"0"1Mo and "1"0"1Tc are reported. Previously published conversion-electron data have been used along with the gamma-ray data to formulate self-consistent decay schemes. (orig.).
An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy
Energy Technology Data Exchange (ETDEWEB)
An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).
1991-12-01
Electron acceleration in supernova remnants and diffuse gamma rays above 1 GeV
DEFF Research Database (Denmark)
The recently observed X-ray synchrotron emission from four supernova remnants (SNRs) has strengthened the evidence that cosmic-ray electrons are accelerated in SNRs. We show that if this is indeed the case, the local electron spectrum will be strongly time-dependent, at least above roughly 30 GeV. The time dependence stems from the Poisson fluctuations in the number of SNRs within a certain volume and within a certain time interval. As far as cosmic-ray electrons are concerned, the Galaxy looks like actively bubbling Swiss cheese rather than a steady, homogeneously filled system. Our finding has important consequences for studies of the Galactic diffuse gamma-ray emission, for which a strong excess over model predictions above 1 GeV has recently been reported. While these models relied on an electron injection spectrum with index 2.4 (chosen to fit the local electron flux up to 1 TeV), we show that an electron injection index of around 2.0 would (1) be consistent ...
1998-01-01
Aspects of two-photon physics at linear e"+e"- colliders
International Nuclear Information System (INIS)
We discuss various reactions at future e"+e"- and #gamma##gamma# colliders involving real (beamstrahlung or backscattered laser) or quasi-real (bremsstrahlung) photons in the initial state and hadrons in the final state. The production of two central jets with large transverse momentum p_T is described in some detail; we give distributions for the rapidity and p_T of the jets as well as the di-jet invariant mass, and discuss the relative importance of various initial state configurations and the uncertainties that arise from the at present rather poor knowledge of the parton content of the photon. We also present results for 'mono-jet' production where one jet goes down a beam pipe, for the production of charm, bottom and top quarks, and for single production of W and Z bosons. Where appropriate, the two-photon processes are compared with annihilation reactions leading to similar final states. We also argue that the behaviour of the total inelastic ...
Studies of basic parameters of electron-counting detection
International Nuclear Information System (INIS)
Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).
1990-05-21
Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system
Energy Technology Data Exchange (ETDEWEB)
The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional ...
2003-05-01
Polymers and paper as packaging materials of irradiated food
International Nuclear Information System (INIS)
Effects of #gamma#-irradiation on synthetic polymers and paper used as packaging materials for irradiated food have been studied by NMR. Polystyrene, polybutadiene and some copolymers were studied before and after the #gamma#-irradiation treatment and in the presence or absence of antioxidants and stabilisers. In the absence of additives, the effect of #gamma#-irradiation on polystyrene is negligible even irradiating at high doses. In turn, the role of antioxidants and stabilisers is crucial in polybutadiene and butadiene-containing copolymers. Wood pulp paper was also studied by NMR. Preliminary measurements on #gamma#-irradiated wood pulp sheets show a shortening in the T_2 relaxation time component due to the bound water, i.e. some of the bound water is lost. (author)
2000-03-01
Neutron star evolution and emission
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.
1997-08-01
Energy Technology Data Exchange (ETDEWEB)
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
1990-12-31
Radon emanation and soil moisture effects on airborne gamma-ray measurements
Energy Technology Data Exchange (ETDEWEB)
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was ...
1997-09-01
Radon emanation and soil moisture effects on airborne gamma-ray measurements
International Nuclear Information System (INIS)
A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was ...
Width of the 1.836-MeV level in "8"8Sr
International Nuclear Information System (INIS)
Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2"+_1 level in "8"8Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.
Terminal-differential algorithm for identification of local non homogeneity in article
International Nuclear Information System (INIS)
Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study
Single Higgs-boson production at a photon-photon collider: general 2HDM versus MSSM
We revisit the production of a single Higgs boson from direct \\gamma \\gamma -scattering at a photon collider. We compute the total cross section \\sigma(\\gamma \\gamma \\to h) (for h=h0, H0, A0), and the strength of the effective g_{h \\gamma \\gamma} coupling normalized to the Standard Model (SM), for both the general Two-Higgs-Doublet Model (2HDM) and the Minimal Supersymmetric Standard Model (MSSM). In both cases the predicted production rates for the CP-even (odd) states render up to 10^4 (10^3) events per 500 \\invfb of integrated luminosity, in full consistency with all the theoretical and phenomenological constraints. Depending on the channel the maximum rates can be larger or smaller than the SM expectations, but in most of the parameter space they should be well measurable. We analyze how these departures depend on the dynamics ...
2011-01-01
International Nuclear Information System (INIS)
In the execution of disposal of low and intermediate level radioactive wastes, it is important to evaluate accurately the kind and quantity of each radionuclide in the wastes. For such an evaluation, correlation of non-gamma-emitting nuclides based on gamma-emitting nuclides is recommended and regarded as a partial method. This method necessitates a completion of a highly accurate and reliable nondestructive assay system of gamma-emitting nuclides for partical use. In 1992, in support of the new waste disposal program in Hungary, Paks NPP initiated a waste characterization program to determine the radiological properties of its rad wastes. A segmented gamma scanning system has been set up to measure the gamma-emitting nuclides in 2000 litre low level drums following in-drum compaction. In the framework of the program a radiochemical analysis sub-program was ...
Proton-neutron interaction in odd--odd indium nuclei
International Nuclear Information System (INIS)
Low-lying nuclear energy levels in "1"1"0In and "1"1"2In were determined from de-excitation #gamma#-rays produced with "1"0"7Ag(#alpha#,n#gamma#)-"1"1"0In, "1"0"8Pd("6Li,4n#gamma#)"1"1"0In, "1"0"9Ag(#alpha#,n#gamma#)"1"1"2In and "1"1"0Pd("6Li,4n#gamma#)"1"1"2In reactions. In addition, the "1"1"4In energy level structure was investigated with the "1"1"0Pd("7Li,3n#gamma#)"1"1"4In reaction. Properties of de-excitation #gamma#-rays were determined from #gamma#-#gamma# coincidence, excitation, and angular distribution measurements conducted with Ge(Li) and Ge(intr.) #gamma#-ray detectors. A sequence of intraconnected levels in each of "1"1"0,"1"1"2,"1"1"4In were assigned to the (#pi#g"-"1/sub 9/2/, #nu#h/sub 11/2/) configuration. For the "1"1"0,"1"1"2,"1"1"4In energy level schemes a ...
1977-01-01
Proton-neutron interaction in odd--odd indium nuclei
International Nuclear Information System (INIS)
An experimental study was performed in order to study the nuclear structure in odd--odd In isotopes. Low lying nuclear energy levels in "1"1"0In and "1"1"2In were determined from de-excitation #gamma#-rays produced with "1"0"7AG(#alpha#,n#gamma#)"1"1"0In, "1"0"8Pd("6Li,4n#gamma#)"1"1"0In, "1"0"9Ag(#alpha#,n#gamma#)"1"1"2In and "1"1"0Pd("6Li,4n#gamma#)"1"1"2In reactions. In addition, the "1"1"4In energy level structure was investigated with the "1"1"0Pd("7Li,3n#gamma#)"1"1"4In reaction. Properties of de-excitation #gamma#-rays were determined from #gamma#--#gamma# coincidence excitation and angular distribution measurements conducted with Ge(Li) and Ge(intr.) #gamma#-ray detectors. A sequence of intraconnected levels in each of "1"1"0 "1"1"2 "1"1"4In were assigned to the ...
1977-01-01
Observation of $X(3872)\\to J/\\psi \\gamma$ and search for $X(3872)\\to\\psi'\\gamma$ in B decays
We report a study of $B\\to (J/\\psi \\gamma) K$ and $B\\to (\\psi' \\gamma)K$ decay modes using $772\\times 10^{6}$ $B\\bar{B}$ events collected at the \\Upsilon(4S)$ resonance with the Belle detector at the KEKB energy-asymmetric $e^+ e^-$ collider. We observe $X(3872) \\to J/\\psi \\gamma$ and report the first evidence for $\\chi_{c2} \\to J/\\psi \\gamma$ in $B\\to (X_{c\\bar{c}}\\gamma) K$ decays, while in a search for $X(3872) \\to \\psi' \\gamma$ no significant signal is found. We measure the branching fractions, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) \\mathcal{B}(X(3872) \\to J/\\psi\\gamma)$ $=$ $(1.78^{+0.48}_{-0.44}\\pm 0.12)\\times 10^{-6}$, $\\mathcal{B} (B^{\\pm} \\to\\chi_{c2} K^{\\pm})$$=$ $(1.11^{+0.36}_{-0.34} \\pm 0.09) \\times 10^{-5}$, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) ...
2011-01-01
International Nuclear Information System (INIS)
In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt gammas ...
2007-09-21
Simultaneous measurement of the neutron capture and fission yields of "2"3"3U
International Nuclear Information System (INIS)
We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)
2007-04-22
Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System
Energy Technology Data Exchange (ETDEWEB)
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
1999-06-01
Choice of energies in gamma-absorption method for layers thickness measuring of two-layers articles
International Nuclear Information System (INIS)
Empirical formulae are proposed for the description of relation between optimum energies minimizing the mean-weighted error of gamma absorption measurement of the thickness of layers in two-layer products with the thickness of every layer from 30 up to 150 mm by carbon. Error of informational parameter approximation with the application of tables does not exceed 10% in case of non-accurate assessment of layers thickness not exceeding 2.5%. Generalized equation is derived which binds main parameters of the task and permits to choose optimum energies with the accuracy sufficient for practical purposes
Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements
International Nuclear Information System (INIS)
A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.
1976-08-11
Energy Technology Data Exchange (ETDEWEB)
DOE/NNSA and IRSN collaborated on a study of gamma-ray instruments and analysis methods used to perform isotopic measurements of special nuclear materials. The two agencies agreed to collaborate on the project in response to inconsistencies that were found in the various versions of software and hardware used to determine the isotopic abundances of uranium and plutonium. IRSN used software developed internally to test the MGA and FRAM isotopic analysis codes for criteria used to stop data acquisition. The stop-criterion test revealed several unusual behaviors in both the MGA and FRAM software codes.
2009-01-01
Raman spectroscopic studies of carbon in extra-terrestrial materials
International Nuclear Information System (INIS)
The measurements obtained here indicate ways in which micro-Raman spectroscopy can be used to elucidate structural characteristics and distribution of carbon in meteorites and interplanetary dust particles (IDPs). Existing information about structurally significant aspects of Raman measurements of graphite is combined with structurally relevant findings from the present micro-Raman studies of carbons prepared by carbonization of polyvinylidine chloride (PVDC) at various temperatures and natural material, as well as several acid residues from the Allende and Murchison meteorites in order to establish new spectra-structure relationships. Structural features of many of the materials in this study have been measured by x ray analysis and electron microscopy: thus, their structural differences can be directly correlated with differences in the Raman spectra. The spectral parameters ...
1990-04-01
Studies on energy level schemes of some nuclei by Gamma-ray spectroscopy
International Nuclear Information System (INIS)
several authors tried to drive codes to construct nuclear level scheme of nuclei using a set of measured gamma -ray transitions and known energy levels, Ritz combination principle proved to be useful in constructing a more complete decay scheme. In this thesis the energy level schemes of some nuclei have been investigated by the measurements of the gamma - ray energies and use of Ritz combination code. The nuclei under investigation are "110m Ag (253 d)"110 Cd and "166m Ho (1200 yr) "166 E r. On the basis of the suggested level at 2249.02 keV by the Ritz code new positions of the two gamma-ray transitions at 677.5 and 706.6 KeV are found in decay scheme of "110m Ag. Also by this code, new position for the 994.84 KeV gamma-ray transition were established to depopulate the level at 1075.2 KeV.
1984-01-01
Neutron capture therapy beam on the LVR-15 reactor
Energy Technology Data Exchange (ETDEWEB)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The ...
1992-01-01
Neutron capture therapy beam on the LVR-15 reactor
International Nuclear Information System (INIS)
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The ...
1991-10-01
Some tests on measuring methods for indoor radon using activated charcoal
Energy Technology Data Exchange (ETDEWEB)
Two methods for measuring indoor radon concentrations using activated charcoal have been tested. The first method is the well-known technique with direct gamma-measurements on the exposed canister after the sampling period. The other method uses a thermoluminescence dosemeter placed in the charcoal canister, giving an integrated value of the radon concentration.
1985-10-01
Use of portable HPGE detector and multichannel analyzer for in-situ gamma spectrometry of soil
International Nuclear Information System (INIS)
Measurement of fission and activation products in the soil or over a plane grass land of a nuclear power station environment is required to find out the long term changes. The inventory of radionuclides in the soil is routinely determined by soil sampling, processing and gamma spectrometry in the laboratory. The method although is proven and accurate is time consuming and largely dependent on homogenous distribution. Therefore, an alternative and rapid method of in-situ gamma spectrometry using portable devices was standardized to determine the concentration of radionuclides in soil, for regular environmental monitoring as well as during emergency condition. The paper presents the methodology, ready to use factors and compares the results of a few measurements made in the environment of Tarapur Atomic Power Station by both in-situ and laboratory methods. (author)
2005-11-23
A detailed analysis of the properties of radiolyzed proteinaceous amino acids
International Nuclear Information System (INIS)
The thermal behaviour of 21 proteinaceous l-amino acids either as pristine samples and also as radiolyzed (3.2 MGy) samples was studied with the differential scanning calorimeter. The onset and peak melting point as well as the melting enthalpy of all samples before and after the radiation treatment was measured and reported. The residual amount of each amino acid survived to the radiation dose of 3.2 MGy (N_#gamma#) was measured from the melting enthalpies before and after radiolysis and hence the radiation resistance of each amino acid has been determined. The radiolysis causes a systematic reduction of the melting enthalpy and a shift of the onset and peak melting point to lower values. It is shown that N_#gamma# does not correlate with the melting points of the amino acids but shows a correlation with the entity of the shift of the melting point peaks occurred after radiolysis. Such correlation ...
2011-03-01
Light particle emission as a probe of the rotational degrees of freedom in deep-inelastic reactions
International Nuclear Information System (INIS)
The emission of #alpha# particles in coincidence with the most deeply inelastic heavy-ion reactions has been studied for "1"8"1Ta + "1"6"5Ho at 1354 MeV laboratory energy and /sup nat/Ag + "8"4Kr at 664 MeV. #alpha# particle energy spectra and angular distributions, in coincidence with a projectile-like fragment, were acquired both in the reaction plane and out of the reaction plane at a fixed in-plane angle. The in-plane data for both systems are employed to show that the bulk of the #alpha# particles in coincidence with the deep-inelastic exit channel can be explained by evaporation from the fully accelerated fragments. Average velocity diagrams, #alpha#-particle energy spectra as a function of angle in several rest frames, and #alpha#-particle angular distributions are presented. The out-of-plane #alpha# particle angular distributions and the #gamma#-ray multiplicities are used to study the transfer and partitioning of ...
EVIDENCE FOR EVOLUTION AMONG PRIMORDIAL DISKS IN THE 5 Myr OLD UPPER SCORPIUS OB ASSOCIATION
International Nuclear Information System (INIS)
Moderate-resolution, near-infrared spectra between 0.8 and 5.2 #mu#m were obtained for 12 late-type (K0-M3) disk-bearing members of the #approx#5 Myr old Upper Scorpius OB association using SpeX on the NASA Infrared Telescope Facility. For most sources, continuum excess emission first becomes apparent between #approx#2.2 and 4.5 #mu#m and is consistent with that produced by single-temperature blackbodies having characteristic temperatures ranging from #approx#500 to 1300 K. The near-infrared spectra for 5 of 12 Upper Scorpius sources exhibit Pa#gamma#, Pa#beta#, and Br#gamma# emission, indicators of disk accretion. Using a correlation between Pa#beta# and Br#gamma# emission line luminosity and accretion luminosity, mass accretion rates ( M-dot ) are derived for these sources that range from M-dot = 3.5x10"-"1"0 to 1.5 x 10"-"8 M_s_u_n yr"-"1. Merging the SpeX observations with ...
2010-11-01
Comparison of the e"+e"-, #gamma#e, #gamma##gamma# linear colliders
International Nuclear Information System (INIS)
The possibility to transform the future linear e"+e"-colliders into the #gamma#e and #gamma##gamma# colliders with approximately the same energies and luminosities was shown earlier. Their properties are compared from the point of view of possible physical investigations on them. 10 refs.; 1 tab.
1992-06-02
International Nuclear Information System (INIS)
We have studied in detail the gamma radiation induced changes in the electrical properties of the (TeO_2)_0_._9 (In_2O_3)_0 _._1 thin films of different thicknesses, prepared by thermal evaporation in vacuum. The current-voltage characteristics for the as-deposited and exposed thin films were analysed to obtain current versus dose plots at different applied voltages. These plots clearly show that the current increases quite linearly with the radiation dose over a wide range and that the range of doses is higher for the thicker films. Beyond certain dose (a quantity dependent on the film thickness), however, the current has been observed to decrease. In order to understand the dose dependence of the current, we analysed the optical absorption spectra for the as-deposited and exposed thin films to obtain the dose dependences of the optical bandgap and energy width of band tails of the localized states. The increase of the current with the ...
2011-02-01
The electron-phonon coupling constant in vanadium
International Nuclear Information System (INIS)
The electron-phonon coupling constant lambda has been calculated for vanadium. The electron energy bands and wave functions were obtained from a model augmented plane wave muffin-tin potential. The electron-phonon matrix elements were evaluated using the rigid-ion approximation and the measured phonon spectra. The results show that lambda is strongly affected by d-f scattering.
Energy Technology Data Exchange (ETDEWEB)
The PAMELA (a Payload for Antimatter-Matter Exploration and Light-nuclei Astrophysics) space mission has been launched on-board the Resurs-DK1 satellite on June 15{sup th} 2006 from the Baikonur cosmodrome, in Kazakhstan. PAMELA is a particle spectrometer designed to study charged particles in the cosmic radiation with special focus on the investigation of the nature of dark matter, by mean of the measure of the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved.
2009-03-15
Radial distribution functions of amorphous silicon
Energy Technology Data Exchange (ETDEWEB)
Substantial changes in the radial distribution function of amorphous Si films have been observed in neutron-diffraction studies. The spectra indicate changes in short-range order associated with an approx.11% modification in the bond-angle distribution width. The results allow the first direct comparison of structural and vibrational Raman probes of variations in local order in thin-film amorphous solids. Good agreement is obtained between the measured bond-angle variation and that based on Raman estimates.
1989-03-15
Neutron scattering studies in the actinide region. Progress report, August 1, 1992--July 31, 1993
Energy Technology Data Exchange (ETDEWEB)
This report discusses the following topics: Prompt fission neutron energy spectra for {sup 235}U and {sup 239}Pu; Two-parameter measurement of nuclear lifetimes; ``Black`` neutron detector; Data reduction techniques for neutron scattering experiments; Inelastic neutron scattering studies in {sup 197}Au; Elastic and inelastic scattering studies in {sup 239}Pu; and neutron induced defects in silicon dioxide MOS structures.
1993-09-01
27: Development of a convolution/superposition method for photon beams
International Nuclear Information System (INIS)
The implementation of the convolution/superposition method in real dose planning situations is considered. The modelling of photon spectra, the use of patient and treatment setup information, and the calculation of the photon energy released in a patient are detailed. A comparison is made between the approaches of calculating the relative dose directly and using a factor derived from measurements to correct the calculated relative dose. 13 refs.; 7 figs.
Energy Technology Data Exchange (ETDEWEB)
{gamma}-ray excitation functions have been measured for the interaction of fast neutrons with {sup 48}Ti (neutron energy from 1 MeV to 250 MeV). The Los Alamos National Laboratory spallation neutron source, at the LANSCE/WNR facility, provided a ''white'' neutron beam which is produced by bombarding a natural W target with a pulsed proton beam. The prompt-reaction {gamma} rays were measured with the large-scale Compton-suppressed Ge spectrometer, GEANIE. Neutron energies were determined by the time-of-flight technique. Excitation functions were converted to partial {gamma}-ray cross sections, taking into account the dead-time correction, the target thickness, the detector efficiency, and neutron flux (monitored with an in-line fission chamber). The data analysis is presented here for neutron energies between 1 to 20 MeV. Partial ...
2005-01-06
Transmission nuclear resonance fluorescence measurements of "2"3"8U in thick targets
International Nuclear Information System (INIS)
Transmission nuclear resonance fluorescence measurements were made on targets consisting of Pb and depleted U with total areal densities near 86g/cm"2. The "2"3"8U content in the targets varied from 0% to 8.5% (atom fraction). The experiment demonstrates the capability of using transmission measurements as a non-destructive technique to identify and quantify the presence of an isotope in samples with thicknesses comparable to the average thickness of a nuclear fuel assembly. The experimental data also appear to demonstrate the process of notch refilling with a predictable intensity. Comparison of measured spectra to previous backscatter "2"3"8U measurements indicates general agreement in observed excited states. Evidence of two new "2"3"8U excited states and possibly a third state have also been observed.
2011-05-15
Energy Technology Data Exchange (ETDEWEB)
As research for the chemical properties of lanthanide molecules in the dry system, electrochemical and ultraviolet-visible optical measurements on the chloride molten salt system have been conducted at Research Reactor Institute, Kyoto University. The reduction behavior of Ln(III)-Ln(0) and Ln(II) are measured on La, Ce, Pr, Nd, Sm, Gd, Tb, Dy, Ho, and Yb by the cyclic voltammetry. The molar absorption coefficients of the f-f transition are measured by the measurement of ultraviolet-visible absorption spectra on Pr, Nd, Ho and Gd. From the comparison of the optical data between wet and dry systems, the characteristics of photon absorption are discussed in the molten salt. (H. Katsuta)
2001-12-01
Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry
International Nuclear Information System (INIS)
A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring ...
1977-11-01
International Nuclear Information System (INIS)
Gamma ray spectra in the decay of 185Ta and 185mW have been studied with Ge (Li) detectors. The 185mW isomeric transition at 131.6 keV is shown to be of E3 multipolarity. A level scheme of 185W is proposed with the following energy levels (energies in keV, spin and K quantum numbers in brackets): 0 (3/2- 3/2), 23.5 (1/2- 1/2), 65.9 (5/2- 3/2), 93.5 (3/2- 1/2) (uncertain), 173.9 (7/2- 3/2), 188.1 (5/2- 1/2), 197.5 (11/2+ 11/2) , 243.5 (7/2- 7/2), and 390.8 (9/2- 7/2)
1996-03-04
Importance of level structure in nuclear reaction cross-section calculations. Revision 1
It is shown that level-density expressions cannot adequately represent or substitute for level structure information when making calculations of the Hauser-Feshbach type for cross sections or isomer-ratios for nuclei in the first few MeV above their ground state. It is stated that such discrete level information should include both experimentally confirmed and theoretically predicted levels. The utility of discrete level information to optimize level density calculations, to compute isomer ratios, in deriving dipole strength functions, and in the analysis of primary gamma ray spectra is emphasized, especially for nuclei far from the line of stability. 29 refs., 12 figs., 6 tabs. (DWL)
1985-11-07
Calculation of neutron and gamma-ray emission spectra produced by p +2''2'Al reactions
International Nuclear Information System (INIS)
As a contribution to the US/Japan cooperative program in fusion neutronics, we have prepared a library of multigroup neutron cross sections, scattering matrices, and covariances (uncertainties and their correlations). This 74-group library, called COVFILS-2, is being used at Los Alamos and at the University of California at Los Angeles in the sensitivity and uncertainty analysis of the Li_2O integral experiment recently performed at the Fast Neutron Source (FNS) in Japan. Another intended use of this library is in the estimation of the uncertainty in key performance parameters (such as breeding ratio) of conceptual fusion reactors. The 14 materials included in the first version of COVFILS-2 are H, "6Li, "7Li, Be, C, N, O, Na, Al, Si, Cr, Fe, Ni, and Pb.
1985-01-01
Assessment of GABARAP self-association by its diffusion properties
Energy Technology Data Exchange (ETDEWEB)
Gamma-aminobutyric acid type A receptor-associated protein (GABARAP) belongs to a family of small ubiquitin-like adaptor proteins implicated in intracellular vesicle trafficking and autophagy. We have used diffusion-ordered nuclear magnetic resonance spectroscopy to study the temperature and concentration dependence of the diffusion properties of GABARAP. Our data suggest the presence of distinct conformational states and provide support for self-association of GABARAP molecules. Assuming a monomer-dimer equilibrium, a temperature-dependent dissociation constant could be derived. Based on a temperature series of {sup 1}H{sup 15}N heteronuclear single quantum coherence nuclear magnetic resonance spectra, we propose residues potentially involved in GABARAP self-interaction. The possible biological significance of these observations is discussed with respect to alternative scenarios of oligomerization.
2010-09-15
Andreev reflection spectroscopy of MgB{sub 2} in the vortex state
Energy Technology Data Exchange (ETDEWEB)
Spectroscopy based on the Andreev reflection (AR) process at the interface between the normal metal tip and the superconductor has become one of the very successful methods for studies in novel exotic superconductors. The method is capable to address the size, symmetry as well as multiplicity of the superconducting order parameter. The method provided one of the first evidences of the two-gap superconductivity in MgB{sub 2} with a detailed temperature dependence of the both gaps. A theory treating the Andreev reflection spectroscopy in the mixed state is missing. We analyse the AR spectra of MgB{sub 2} in the mixed state via modelling the magnetic pair-breaking by the increasing spectral broadening parameter {gamma}. As a result a non-trivial pair breaking effect in the {pi}-band is found.
2004-05-01
International Nuclear Information System (INIS)
At atmospheric pressure and room temperature, dielectric barrier discharge induced plasma oxidation for achieving supported TiO2 photocatalysts derived from TiCl4 adsorbed onto ?-Al2O3 pellets was studied. The supported TiO2/?-Al2O3photocatalysts prepared by a cyclic 'adsorption-discharge' approach, without requirement of heat treatment, exhibit high activity in the photocatalytic degradation reaction of formaldehyde. The mass spectra and optical emission spectra during O2/Ar discharge for oxidizing the adsorbed-state TiCl4 were measured. The mechanism for the TiO2 formation from adsorbed-state TiCl4 by plasma oxidation was discussed.
2007-03-21
International Nuclear Information System (INIS)
The absorption and magnetic circular dichroism spectra of [N(n-Bu)_4]"+[(MeCp)_3PrCl]"- dissolved in 2-MeTHF were measured at room and at low temperatures. On the basis of these spectra the crystal field splitting pattern could be derived. The parameters of an empirical Hamiltonian were fitted to the energies of 42 levels to give an r.m.s. deviation of 23 cm"-"1. From the crystal field parameters obtained the crystal field strength of the ligand collective was estimated. Compared with neutral Cp_3Pr circle B complexes the crystal field strength of the anionic [(MeCp)_3PrCl]"- moiety is unusually low. (orig.)
1998-07-24
International Nuclear Information System (INIS)
The absorption spectra of an unoriented single crystal of the title compound (1) have been measured at room and at low temperatures. Assuming a similar sequence of crystal field (CF) levels as for the previously analyzed Nd[N(SiMe_3)_2]_3 (2) a truncated CF splitting pattern is derived from the spectra obtained. The parameters of an empirical Hamiltonian are fitted to the energies of 71 levels to give an r.m.s. deviation of 24.2 cm"-"1. The parameters obtained are compared with those of 2 and Nd[N(SiMe_3)_2]_3(CNC_6H_1_1)_2 (3). The observed trends of CF parameters are consistent with the results of simple model calculations in the framework of the angular overlap model. (orig.)
1998-07-24
Cosmological Information from Lensed CMB Power Spectra
Gravitational lensing distorts the cosmic microwave background (CMB) temperature and polarization fields and encodes valuable information on distances and growth rates at intermediate redshifts into the lensed power spectra. The non-Gaussian bandpower covariance induced by the lenses is negligible to l=2000 for all but the B polarization field where it increases the net variance by up to a factor of 10 and favors an observing strategy with 3 times more area than if it were Gaussian. To quantify the cosmological information, we introduce two lensing observables, characterizing nearly all of the information, which simplify the study of non-Gaussian impact, parameter degeneracies, dark energy models, and complementarity with other cosmological probes. Information on the intermediate redshift parameters rapidly becomes limited by constraints on the cold dark matter density and initial amplitude of fluctuations as observations improve. Extraction of this information ...
2006-01-01
International Nuclear Information System (INIS)
Comparisons of calculated neutron yield distributions from #alpha#-particle induced reactions on thick targets are made with measured data to analyze the initial reaction process in the framework of the exciton (hybrid) model code ALICE91 (M. Blann, Lawrence Livermore National Laboratory Report UCID 19614, 1982). We have considered two reaction mechanisms: dissolution of the #alpha# in the nuclear field, and preequilibrium processes initiated by #alpha#-nucleon collisions. Both these processes seem to contribute to the emitted neutron spectra in varying proportions depending on the incident #alpha# energy and possibly on the target nucleus. Contributions from other processes appear to be non-negligible.
2003-06-01
International Nuclear Information System (INIS)
The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.
Studies of a Poenitz-type black neutron detector as a neutron flux monitor
Energy Technology Data Exchange (ETDEWEB)
A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).
1997-04-01
Structural, Vibrational and Mechanical Studies of Hydroxyapatite produced by wet-chemical methods
Hydroxyapatite samples were produced by two different wet-chemical methods, and characterized by x-ray diffraction, infrared and compression strength measurements. The x-ray diffraction measurements were simulated using the Rietveld method, and structural data as lattice parameters and average crystallite size were obtained. The infrared spectra showed the presence of CO$_3^{2-}$ ions in all samples, indicating a contamination by these ions. By mixing samples produced by both methods, a bioceramic was obtained and, after sintering, samples with very high compression strengths (26--30 MPa) were obtained.
2004-01-01
Production of cumulative pions and kaons
International Nuclear Information System (INIS)
#pi#"#+-# and K"#+-# cumulative production in pA #-># #pi#"#+-#+x and pA #-># K"#+-#+x reactions at 10.14 GeV proton beam energy on nuclei (Be-Ta) was invesigated. Measurements were conducted using FAS-1 focusing hadron spectrometer. Invariant cross sections of #pi#"#+-# and K"#+-# cumulative production, values of ratio of this cross sections, dependences of production cross sections for pions and kaons on cumulative number and mass number of nucleus target, as well as on transverse momentum are measured. Difference of cumulative meson spectra occurring in different nuclei fragmentation is discussed in terms of flucton model. 17 refs.; 14 figs.
1988-06-14
Laser photoelectron spectroscopy of ions. Progress report, August 1, 1982-July 31, 1983
Energy Technology Data Exchange (ETDEWEB)
We have undertaken a program which measures the photoelectron spectra of negative-ion beams. This experiment has afforded us direct information about these ions and the corresponding neutral radicals. Several ions and numerous radicals are believed to be crucial intermediates in combustion processes and flame chemistry. We have fabricated a spectrometer which directly measures electron affinities (EA). Knowledge of the EA and gas-phase acidity of a radical has enabled us to deduce several radical heats of formation and bond strengths.
1983-03-01
Fission yield measurements by inductively coupled plasma mass-spectrometry
International Nuclear Information System (INIS)
Correct prediction of the fission products inventory in irradiated nuclear fuels is essential for accurate estimation of fuel burnup, establishing proper requirements for spent fuel transportation and storage, materials accountability and nuclear forensics. Such prediction is impossible without accurate knowledge of neutron induced fission yields. The uncertainty of the fission yields reported in the ENDF/B-VII.0 library is not uniform across all of the data and much of the improvement is desired for certain fissioning isotopes and fission products. We discuss our measurements of cumulative fission yields in nuclear fuels irradiated in thermal and fast reactor spectra using Inductively Coupled Plasma Mass Spectrometry. (author)
2009-11-01
Fission yield measurements by inductively coupled plasma mass-spectrometry
British Library Electronic Table of Contents (United Kingdom)
Correct prediction of the fission products inventory in irradiated nuclear fuels is essential for accurate estimation of fuel burnup, establishing proper requirements for spent fuel transportation and storage, materials accountability and nuclear forensics. Such prediction is impossible without accurate knowledge of neutron induced fission yields. The uncertainty of the fission yields reported in the ENDF/B-VII.0 library is not uniform across all of the data and much of the improvement is desired for certain fissioning isotopes and fission products. We discuss our measurements of cumulative fission yields in nuclear fuels irradiated in thermal and fast reactor spectra using Inductively Coupled Plasma Mass Spectrometry.
2009-01-01
Daya Bay reactor anti-neutrino experiment
International Nuclear Information System (INIS)
The Daya Bay Reactor Anti-Neutrino Experiment is a neutrino oscillation experiment designed to observe and measure the neutrino mixing angle ?13. The sensitivity goal is 0.01 in sin 22?13 at the 90% confidence level, a significant improvement over the current limit. This will be accomplished by measuring the relative rates and energy spectra of reactor electron antineutrinos with multiple detectors positioned at different baselines. Civil construction is currently under-way as detector designs and planning near completion. Commissioning activities should be completed by the end of 2010, followed by a three-year run.
2008-11-01
Real-time neutron radiography system performance - Measurements and methods
Energy Technology Data Exchange (ETDEWEB)
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, ...
1988-09-01
Real-time neutron radiography system performance - Measurements and methods
International Nuclear Information System (INIS)
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in ...
1988-01-01
Stereoscopic observations of a solar hard x-ray flare with Ulysses, PVO, GRO and Yohkoh spacecraft
Energy Technology Data Exchange (ETDEWEB)
Hard X-ray/gamma-ray spectrometers aboard two interplanetary spacecraft, Ulysses and Pioneer Venus Orbiter (PVO), and two near-Earth spacecraft, Yohkoh and Compton Gamma Ray Observatory (GRO/BATSE), are currently in operation. A unique set of circumstances have permitted the observation of the 15 November 1991 (2238 UT) flare by all the four instruments. This intense flare (GOES class X 1.5) was associated with the bright (3B) H-alpha flare located on the disk (S13, W19) in the active region 6919. At the time of the flare, the Ulysses and PVO spacecraft were located respectively 101[degree] and 52[degree] west of the Sun-Earth line. Thus the view angles for the PVO and Ulysses instruments were quite different from those of the near-Earth instruments on GRO and Yohkoh. The preliminary photon energy spectra observed by the four instruments at different times during the flare will be presented and their implications regarding ...
1992-01-01
Relationships between cosmic ray neutron flux and rain flows
International Nuclear Information System (INIS)
The registration of secondary cosmic ray neutrons is a convenient tool for the investigation of primary cosmic ray variations and for meteorological effects as well. At present a large network of neutron monitors exists, aiming at studies of cosmic ray variations which are related to interplanetary conditions and geomagnetic activity. At the same time cosmic ray variations may be related to some atmospheric processes. In this connection, using the data from two neutron monitors (a standard and a lead free one), a gamma detector from Moscow station and lead free neutron monitor at BEO Moussala, we studied the correlations between rain flows and neutron flux. In this study we used daily averages on the basis of 10 min data for the neutron flux, corrected for barometric pressure and data from local meteo-stations. The preliminary analysis indicates a correlation between rain flows and neutron flux in several cases. To explain observable correlations, calculations of ...
2008-09-01
FFTF fission gas monitor computer system
International Nuclear Information System (INIS)
The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or maintenance without interrupting the overall system functions. A built-in calibrated ...
We report the first observation of the radiative decay B^0 -> \\phi K^0 \\gamma using a data sample of 772 x 10^6 B B-bar pairs collected at the \\Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric-energy e^+e^- collider. We observe a signal of 37+/-8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is ${\\cal B}(B^0 -> \\phi K^0 \\gamma) = (2.74\\pm 0.60 \\pm 0.32) \\times 10^{-6}$, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP violation parameters: ${\\mathcal S}_{\\phi K_S^0 \\gamma} = +0.74^{+0.72}_{-1.05} (stat)^{+0.10}_{-0.24} (syst)$ and ${\\mathcal A}_{\\phi K_S^0 \\gamma} = +0.35 +/- 0.58 (stat)^{+0.23}_{-0.10} (syst)$. Furthermore, we measure ${\\mathcal ...
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Following the successful application of hydrostatic pressure in mechanistic investigations of organic reactions, chemists have launched a vigorous effort to apply this tool to substitution reactions of coordination compounds. The authors began to study pressure effects in the NMR spectra of keton-lanthanide combination with the hope that the increase shifts anticipated might enhance the utility of the method, perhaps even expand its applicability to new classes of compounds. 5-Phenyl- and 5-tert-butyladamantan-2-one, piperidine, tetrahydrofuran, and cyclopentanol exhibited pressure-reduced lanthanide-induced shifts with Eu(fod)/sub 3/; Yb(fob)/sub 3/ and the shielding reagent Pr(fod)/sub 3/ showed the same effect with adamantanone. Solvent variations (CD/sub 2/Cl/sub 2/, CCl/sub 4/) caused minor changes in the magnitude of these shifts but did not reverse any. With the objective of learning whether these effects are due to a suppressed equilibrium population or to ...
1987-11-11
Line intensity enhancements in stellar coronal X-ray spectra due to opacity effects
Context. The I(15.01 A)/I(16.78 A) emission line intensity ratio in Fe XVII has been reported to deviate from its theoretical value in solar and stellar X-ray spectra. This is attributed to opacity in the 15.01 A line, leading to a reduction in its intensity, and was interpreted in terms of a geometry in which the emitters and absorbers are spatially distinct. Aims. We study the I(15.01 A)/I(16.78 A) intensity ratio for the active cool dwarf EV Lac, in both flare and quiescent spectra. Methods. The observations were obtained with the Reflection Grating Spectrometer on the XMM-Newton satellite. The emission measure distribution versus temperature reconstruction technique is used for our analysis. Results. We find that the 15.01 A line exhibits a significant enhancement in intensity over the optically thin value. To our knowledge, this is the first time that such an enhancement has been detected on such a sound statistical ...
2008-01-01
Nuclear magnetic moment measurements through hyperfine interactions in highly stripped ions
International Nuclear Information System (INIS)
Time-differential magnetic moment measurements on the first-excited Isup(#pi#)=2"+ states in "2"0Ne and "2"4Mg with mean lives of 1.0 and 2.1 ps, respectively are described. The lifetime of the latter state was determined simultaneously. A special detection geometry was designed to improve the experimental #gamma#-ray anisotropy measured with finite-size detectors. For "2"0Ne also a time-integral measurement with charge-state separation was performed. The necessary electronics circuitry built to perform these complicated measurements and the plunger assembly with laser interferometer are also described. A magnetic moment measurement of "2"2Ne(2_1"+) with tau=5.0 ps and transient field measurements at low and high recoil velocities are reported. A discussion of possible extensions of the techniques are given. (Auth.).
1975-09-15
Serum gamma-glutamyltransferase is associated with arterial stiffness in healthy individuals
British Library Electronic Table of Contents (United Kingdom)
Summary Objective- Gamma-glutamyltransferase (GGT) has been reported to be useful in predicting cardiovascular disease. Arterial stiffness measured by brachial-ankle pulse wave velocity (baPWV) is not only a marker of vascular damage but a significant predictor of cardiovascular events. Gender difference has been reported in the association between GGT and baPWV. We assessed, therefore, the association between GGT and baPWV in a large population and determined whether there was gender difference. Design- This cross-sectional study was conducted at the Asan Medical Centre, Seoul, Republic of Korea. Subjects and measurements- Serum GGT, baPWV and conventional risk factors were measured in 10 988 apparently healthy subjects (7248 men, 3740 women) who participated in a routine health screening...
2011-01-01
Quantitative measurement of elements in a composite, using multienergy gamma-rays
International Nuclear Information System (INIS)
This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the ...
QCD corrections to top quark pair production in association with a photon at hadron colliders
We compute QCD corrections to the production of a ttbar pair in association with a hard photon at the Tevatron and the LHC. This process allows a direct measurement of the top quark electromagnetic couplings that, at the moment, are only loosely constrained. We include top quark decays, treating them in the narrow width approximation, and retain spin correlations of final-state particles. Photon radiation off top quark decay products is included in our calculation and yields a significant contribution to the cross-section. We study next-to-leading order QCD corrections to the ppbar -> ttbar+gamma process at the Tevatron for the selection criteria used in a recent measurement by the CDF collaboration. We also discuss the impact of QCD corrections to the pp -> ttbar+gamma process on the measurement of the top quark electric charge at the 14 TeV LHC.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
The production of three vector bosons in {gamma} {gamma} collisions studying the reactions {gamma} + {gamma} {yields} W{sup +} + W{sup -} + Z{sup 0} and {gamma} + {gamma} {yields} W{sup +} + W{sup -} + {gamma}. 12 refs., 4 figs., 2 tabs.
1994-12-31
International Nuclear Information System (INIS)
Neutron energy spectra were measured for two OSURR experimental facilities. The method of multiple foil activation was used with the SAND-II neutron spectrum unfolding code to obtain spectral data for the Central Irradiation Facility and Rabbit tube. Limited data was obtained for the thermal column using only gold foils. Calculations were made of the neutron environment in various locations using the MORSE code. A shift towards higher neutron energies was observed comparing results for LEU and HEU cores. A slight loss in total thermal neutron flux was measured for all positions. Calculational results show reasonable agreement with measured data.
1993-07-01
Remote temperature inversion sensor
International Nuclear Information System (INIS)
In conducting aircraft surveys for uranium, it is found that temperature inversions can give spurious results because they promote accumulation of radon gas in the atmosphere. The "2"1"4Bi (daughter product of radon) gamma-rays detected from the atmosphere-borne radon are difficult to separate from the "2"1"4Bi gamma-rays originating from the ground, and providing a signature for uranium deposits. The purpose of the present study was to examine the feasibility of making remote temperature soundings of the atmosphere below a low-flying aircraft (140 m or less above ground) by the inversion of radiance measurements taken in the 15-micron carbon dioxide absorption band. Such measurements would identify those temperature inversion conditions possibly leading to an unacceptably large background of gamma-rays from the atmospheric radon. Thus, the incidence of spurious aerial survey data ...
1977-01-01
International Nuclear Information System (INIS)
A method that employs simultaneous neutron and #gamma#-ray diffraction techniques is proposed for accurate measurements of strains with or without an applied electric field (0-100 kV m"-"1). Instead of an absolute determination of the position of the neutron Bragg peak, a relative measurement of the neutron and #gamma# peak positions is used and allows a determination of the lattice-parameter changes with an accuracy of within 2 x 10"-"6. This technique avoids systematic errors originating in sample rotations by taking advantage of a reference directly related to the crystal lattice. The method appears to be particularly important for crystals that exhibit structural phase transitions, as demonstrated by the measurement of the strain U_x_x in KH_2PO_4 crystals as a function of temperature and applied electric field. In this case the errors would amount to #+-#20%. The results ...
1987-12-01
Corrections for non-homogeneity of the sample in Moessbauer f-factor measurements
Energy Technology Data Exchange (ETDEWEB)
We describe a procedure for correcting the systematic errors in the Moessbauer f-factor measurement due to non-homogeneous effective thickness of the sample. To be more precise, we show that, if the mass of the sample is determined by means of X- or {gamma}-ray absorption, it is possible to establish experimental conditions so that the error on f due to material non-homogeneity in the sample is minimized.
2002-06-01
Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization
Energy Technology Data Exchange (ETDEWEB)
The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically ...
2008-05-22
Development of food preservation and processing techniques by radiation
International Nuclear Information System (INIS)
Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as genotoxicity, acute ...
1988-04-18
Year-1 (heavy-ion) physics with CMS at the LHC
International Nuclear Information System (INIS)
The plans for the CERN LHC heavy ion program in 2010 are for collisions of lead ions during the month of November at an energy about half of the final 5.5 TeV/nucleon. The advanced preparations are mostly for extrapolations of the measurements at the maximum energy previously available, Au + Au at 0.2 TeV/nucleon. Because of the large increase in energy, surprises can be expected. One new feature made possible by the increased energy and the excellent muon energy resolution of CMS will be the study of the yields of the excited states of the upsilon meson as a function of angle and centrality. Although the main emphasis will be on the QGP formed by the overlapping parts of the Pb ions, the spectator parts and the electromagnetic field outside of the ions, #gamma#-Pb and #gamma##gamma#, are also important.
2010-06-01
Using about $226\\times 10^6$ $\\jpsi$ events and $106\\times 10^6$ $\\psi^{\\prime}$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider, the Dalitz plot of $\\etap \\to \\eta \\pi^+ \\pi^-$ decay is studied, the direct measurement of $a^{0}_{0}(980)-f_{0}(980)$ mixing is performed, $X(2120)$ and $X(2370)$ are observed in the $\\pi^+\\pi^-\\eta^\\prime$ invariant mass spectrum, $\\psi^{\\prime}\\to\\gamma\\pi^0$ and $\\psi^{\\prime}\\to\\gamma\\eta$ are observed for the first time, and the decays $\\chi_{cJ}\\to\\gamma V$ ($V=\\phi$, $\\rho^0$, $\\omega$) are studied.
2010-01-01
PHOTON-HADRON INTERACTIONS AT RHIC AND LHC ENERGIES.
Energy Technology Data Exchange (ETDEWEB)
Heavy Ion Collisions at RHIC and LHC energies are potentially an interesting laboratory for the study of QED. In these collisions, a Heavy Ion in one beam sees a highly Lorentz contracted electric field due to an oncoming beam particle. The Electric field reaches a maximum value of E {approx_equal} {gamma}{sub eff} {center_dot} Z {center_dot} e/b{sup 2}, where the apparent Lorentz factor, {gamma}{sub eff} = 2 {center_dot} {gamma}{sub beam}{sup 2} - 1. The collision may be viewed in terms of a flux of photons colliding with a stationary ion target using the equivalent photon approximation, originally introduced by Fermi in 1924. We show that the cross section for Inelastic Electromagnetic Interactions of Heavy Ions are both calculable and have been measured in the first RHIC running period.
2002-03-01
Interpretation of gamma-scanning data from the ORR demonstration elements
Energy Technology Data Exchange (ETDEWEB)
The HEU and LEU fuel elements used in the ORR whole-core demonstration were gamma-scanned to determine the axial distribution of the {sup 140}La and {sup 137}Cs activities. Analysis of this data is now complete. From the {sup 140}La activity distributions cycle-averaged powers were determined while the {sup 137}Cs data provided a measure of the final {sup 235}U burnup in the fuel elements. A method for calculating correction factors for activity gradients transverse to the fuel element axis is presented and is applied to the first mixed core used in the demonstration during the gradual transition to an all LEU core. Results based on the gamma-scanning of the LEU fuel followers are also presented. Improved burnup calculations against which the experimental results are to be compared are now in progress. 7 refs., 21 figs., 3 tabs.
1989-01-01
Transverse polarization of top quarks produced at a photon-photon collider
Energy Technology Data Exchange (ETDEWEB)
At future [gamma][gamma] colliders copious production of [ital t] [bar t] pairs is possible. This would allow for a detailed investigation of the interactions involving the top quark. We propose some correlations which are sensitive to [ital t] [bar t] final state interactions and we compute the QCD and standard model Higgs boson contributions to these correlations. A correlation resulting from the QCD induced transverse polarization of top quarks is found to be sizable and measurable at a high energy [ital e][sup +][ital e][sup [minus
1995-03-01
Transverse polarization of top quarks produced at a photon-photon collider
Energy Technology Data Exchange (ETDEWEB)
At future {gamma} {gamma} colliders a massive production of tt-bar pairs is possible. This would allow a detailed investigation of the interactions involving the top quark. The authors propose some correlations which are sensitive to tt-bar final state interactions and compute the QCD and standard model Higgs boson contributions to these correlation. QCD-induced transverse polarization of top quarks is found to be sizeable and measurable at a high-energy e{sup +} e{sup -} collider with an integrated luminosity of 10(fb){sup -1} which is converted into a photon collider by backscattering of laser photons. 16 refs.
1995-10-01
Transverse polarization of top quarks produced at a photon-photon collider
International Nuclear Information System (INIS)
At future #gamma##gamma# colliders copious production of t bar t pairs is possible. This would allow for a detailed investigation of the interactions involving the top quark. We propose some correlations which are sensitive to t bar t final state interactions and we compute the QCD and standard model Higgs boson contributions to these correlations. A correlation resulting from the QCD induced transverse polarization of top quarks is found to be sizable and measurable at a high energy e"+e"- collider, which is operated as a photon collider through backscattering of laser photons, at an integrated luminosity of 10 fb"-"1.
Three-dimensional data processing for time resolved gamma-ray spectrometry
International Nuclear Information System (INIS)
A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method. (author)
Energy Technology Data Exchange (ETDEWEB)
Natural radioactivity found in rocks and its evaluation been frequently used for studies of environmental geochemistry, particularly those of detection and control of pollutants and the consequent changes in environment after antropic interferences. In this work natural radioactivity in forty nine soil samples in the basin of Buquira river, at the Northeast region of Sao Paulo State, has been analysed and measured with a Ge-HP gamma ray spectrometer. A table with the most relevant results found in rocks is shown and discussed. (author)
2002-12-01
Radiation hardness of plastic scintillating fiber
International Nuclear Information System (INIS)
We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).
Neutron activation analysis of trace elements in Japanese hormesis cosmetics
International Nuclear Information System (INIS)
In Japan, cosmetics claiming hormesis effect are available through Internet. Although these cosmetics show the contents, they never mention the minor elements and radioactive sources. The existence of radioisotopes, however, was observed by measurements of the gamma-rays with a HPGe detector. In this study, in order to clarify the contents of trace elements, the hormesis cosmetics including radioactive sources were analyzed using INAA, PGAA and NAA with multiple gamma-ray detection (NAAMG). Nineteen elements were analyzed quantitatively in hormesis cosmetics by INAA, PGAA and NAAMG and 16 elements were detected qualitatively by SEM-EPMA. (author)
2008-12-01
Gamma-radiation-induced wood-plastic composites from Syrian tree species
Energy Technology Data Exchange (ETDEWEB)
Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.
2001-05-01
Gamma-radiation-induced wood-plastic composites from Syrian tree species
International Nuclear Information System (INIS)
Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.
2001-05-01
Gamma-radiation-induced wood-plastic composites from Syrian tree species
International Nuclear Information System (INIS)
Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)
2002-01-01
Electron capture decay of sup 203 Pb
Energy Technology Data Exchange (ETDEWEB)
Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).
1989-01-01
Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide
British Library Electronic Table of Contents (United Kingdom)
Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...
2006-01-01
$B \\to X_{s} \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ decays at LHCb
\\lhcb is one of the four major experiments at the Large Hadron Collider (\\lhc) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavour hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiments. In this article, the \\lhcb prospects for such measurements with exclusive decays of the type $B \\to \\Xs \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ are presented.
2011-01-01
$B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ decays at LHCb
LHC$b$ is one the four major experiments at the Large Hadron Collider (LHC) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavor hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiment. In this article, the LHC$b$ prospects for such measurement with exclusive decays of the type $B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ are presented.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, ...
1997-07-01
International Nuclear Information System (INIS)
In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range ...
2001-06-17
International Nuclear Information System (INIS)
The research performed during this reporting period (9/1/84 to 8/31/85) resulted in: (1) publication of three papers; (2) presentation of an invited paper to the conference on ''Neutron-Nucleus Collisions: A Probe of Nuclear Structure''; (3) presentation of three contributed papers at APS meetings; and (4) preparation of three manuscripts, two of which are in the process of internal review at the Oak Ridge National Laboratory and are included with this report, and the third is being typed as this report is being written. The publications and papers deal with topics in both nuclear structure and astrophysics. Our efforts to study the systematic behavior of the optical model potential in the energy region just above neutron binding has been made substantially more reliable with the publication of a paper which discusses the accuracy of the methods used to average the measured scattering matrix. In the area of stellar nucleosynthesis, comparison of our model ...
Energy Technology Data Exchange (ETDEWEB)
A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste container. This is particularly true when the ...
1997-05-01
Energy Technology Data Exchange (ETDEWEB)
A study has been made of the reaction [sup 86]Kr + [sup 63]Cu at incident energies of 486, 550, 640, and 730 MeV. Measurements include cross sections, angular distributions, and energy spectra for light charged particles ([sup 1,2,3]H and [sup 4]He), intermediate mass fragments (IMF) (4 [le] Z [le] 17), and heavy fragments (Z [ge] 18). Coincidences between light charged particles and between particles and fragments have been measured to obtain cross sections, energy spectra, and angular distributions. Statistical model analysis of the energy spectra for [sup 1]H and [sup 4]He detected in coincidence with the fragments has allowed estimation of [sup 1]H and [sup 4]He multiplicities associated with the evaporation residues, fragments, and composite nuclei prior to scission. A comparison of cross sections, energy spectra, angular distributions, and particle ...
1992-01-01
Excited leptons and quarks at #gamma##gamma#/#gamma#e colliders
International Nuclear Information System (INIS)
We discuss the search of excited leptons and quarks with spin 1/2 at #gamma##gamma# and at #gamma#e colliders. We show that #gamma##gamma# colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l"*l#gamma# transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).
Gravitational parity violation is a possibility motivated by particle physics, string theory and loop quantum gravity. One effect of it is amplitude birefringence of gravitational waves, whereby left and right circularly-polarized waves propagate at the same speed but with different amplitude evolution. Here we propose a test of this effect through coincident observations of gravitational waves and short gamma-ray bursts from binary mergers involving neutron stars. Such gravitational waves are highly left or right circularly-polarized due to the geometry of the merger. Using localization information from the gamma-ray burst, ground-based gravitational wave detectors can measure the distance to the source with reasonable accuracy. An electromagnetic determination of the redshift from an afterglow or host galaxy yields an independent measure of this distance. Gravitational parity violation would manifest ...
2010-01-01
Performance of the AMS-02 Experiment for High Energy Gamma Ray Astrophysics
AMS is a particle detector designed to perform high precision measurements of the cosmic rays fluxes with the main goals of searching for anti-nuclei, as remnants of primordial anti-matter, and of measuring the faintest components of the cosmic flux, anti- protons, positrons and high energy photons. To fulfill the requirements of large acceptance, long exposure time and excellent particle identification needed to achieve the intended results, AMS will operate in space as an attached payload to the International Space Station (ISS), being the first full featured particle physics experiment to operate in the Earth orbit. The AMS-02 accurate measurements of cosmic-ray nuclei, protons, antiprotons, electrons and positrons will be completed by high energy gamma rays detection. The experiment will detect gamma-rays, either by reconstructing e+e? pairs generated by photons converted ...
2007-01-01
Modified Fragmentation Function in Heavy Ion Collisions at RHIC via Direct photon-Jet Measurements
The presented results are the first measurements at RHIC for direct $\\gamma$-charged hadron azimuthal correlations in heavy ion collisions. We use these correlations to study the color charge density of the medium through the medium-induced modification of high-p$_T$ parton fragmentation. Azimuthal correlations of direct photons at high transverse energy (8 $<$ p$_T$ $<$ 16 GeV) with away-side charged hadrons of transverse momentum (3 $<$ p$_T$ $<$ 6 GeV/c) have been measured over a broad range of centrality for $Au+Au$ collisions and $p+p$ collisions at $\\sqrt{s_{NN}}$ = 200 GeV in the STAR experiment. A transverse shower shape analysis in the STAR Barrel Electromagnetic Calorimeter Shower Maximum Detector is used to discriminate between the direct photons and photons from the decays of high p$_T$ $\\pi^{0}$. The per-trigger away-side yield of direct $\\gamma$ is smaller than from ...
2008-01-01
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation ...
2005-01-01
Implementation of FFT convolution and multigrid superposition models in the FOCUS RTP system
International Nuclear Information System (INIS)
In radiotherapy treatment planning, convolution/superposition algorithms currently represent the best practical approach for accurate photon dose calculation in heterogeneous tissues. In this work, the implementation, accuracy and performance of the FFT convolution (FFTC) and multigrid superposition (MGS) algorithms are presented. The FFTC and MGS models use the same 'TERMA' calculation and are commissioned using the same parameters. Both models use the same spectra, incorporate the same off-axis softening and base incident lateral fluence on the same measurements. In addition, corrections are explicitly applied to the polyenergetic and parallel kernel approximations, and electron contamination is modelled. Spectra generated by Monte Carlo (MC) modelling of treatment heads are used. Calculations using the MC spectra were in excellent agreement with measurements for many linear ...
2000-04-01
Energy Technology Data Exchange (ETDEWEB)
The study of audible noise from high voltage transmission lines and a high voltage transformer station was conducted in three parts. Part 1 consisted of long-term measurement and statistical analysis by computer reduction of audible noise as a result of corona discharge from high voltage transmission lines and the associated weather conditions which contribute to this noise. Recommendations are given concerning further computer programming in order to improve the statistical reliability of corona noise presence and reduce the degree of background noise contamination of the present results. Part 2 consisted of categorizing and cataloguing of corona noise spectra from long-term measurements on 550, 735 and 765 kV transmission lines and to provide a library of such sounds on magnetic tape to be used in the ongoing study of corona noise. Twenty-five different corona sound spectra have been identified and ...
1986-11-01
The Italian survey as the basis of the national radon policy
Energy Technology Data Exchange (ETDEWEB)
One of the most important goals of the Italian survey, initiated in 1989, was to promote ad hoc policies to reduce radon exposure of the population. In the survey a statistical representative sample of 5000 dwellings was chosen; two six-month measurements were made of the indoor radon concentration, in combination with one six-month measurement of gamma exposure. The results of the radon concentration measurements are reported here: they refer to 80% of the sample. The annual mean value was 81.5Bq.m{sup -3}, which is higher than that reported for other industrialised countries. (author).
1994-12-31
Radon measurements in dwellings using activated charcoal
Energy Technology Data Exchange (ETDEWEB)
In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.
1984-01-01
Measurement of the inclusive Z production cross section with the CMS detector
First measurements of inclusive Z production cross sections in muon and electron decay channels at 7 TeV are presented for proton-proton collisions in the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). The comparison of the kinematic quantities as well as the studies of selection efficiencies demonstrate a good agreement between simulated events and current data. The measured inclusive cross section for Z($\\gamma^{*}$) production agrees with NNLO QCD cross section calculations and current parton distribution functions.
2010-01-01
Half-lives of the T{sub z}=1/2 series nuclei, {sup 81}Zr and {sup 85}Mo
Energy Technology Data Exchange (ETDEWEB)
The nuclei {sup 81}Zr and {sup 85}Mo with T{sub z}=1/2 have been reinvestigated via their {beta}-delayed proton emissions with p-{gamma} coincidence measurement. The half-life of {sup 81}Zr has been measured to be 5.3{+-}0.5 s, which agrees with one of the two previous values. For {sup 85}Mo, the measured half-life is 3.2{+-}0.2 s, which revises the previous value. (orig.) With 3 figs., 12 refs.
1997-12-01
Half-lives of the T_z=1/2 series nuclei, "8"1Zr and "8"5Mo
International Nuclear Information System (INIS)
The nuclei "8"1Zr and "8"5Mo with T_z=1/2 have been reinvestigated via their #beta#-delayed proton emissions with p-#gamma# coincidence measurement. The half-life of "8"1Zr has been measured to be 5.3#+-#0.5 s, which agrees with one of the two previous values. For "8"5Mo, the measured half-life is 3.2#+-#0.2 s, which revises the previous value. (orig.).
FFTF shield and gamma ray measurements
Energy Technology Data Exchange (ETDEWEB)
Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.
1984-08-01
Energy Technology Data Exchange (ETDEWEB)
The feasibility of spectroscopic measurement of the velocity distribution of alpha particle using the ablation cloud of a lithium or boron pellet was tested in the DT experiment of TFTR. The measurement was performed using a 10-channel narrow-band filtered spectrometer in the wavelength covering the 3.5 MeV alpha particle Doppler broadening region of the He II 468.6 nm line and its vicinity. The spectra from a lithium pellet consists of the continuum bremsstrahlung background, lithium line emissions and possibly a 468.6 nm helium line. However, no clear evidence of alpha particles was observed, even when boron pellets were injected. (orig.) 4 refs.
1997-03-01
A combined interpretation of cosmic ray and antiproton high energy measurements
Energy Technology Data Exchange (ETDEWEB)
In the last months several ballon and satellite experiments improved significantly our knowledge of cosmic ray (CR) spectra at high energy. In particular CREAM allowed to measure B/C, C/O and N/O ratios up to 1 TeV/n and PAMELA the anti p/p ratio up to 100 GeV with unprecedented accuracy. These measurements offer a valuable probe of CR propagation properties. We performed a statistical analysis to test the compatibility of these results, as well as other most significant experimental data, with the predictions of a new numerical CR diffusion package (DRAGON). We found that above 1 GeV/n all data are consistent with a plain diffusion scenario and point to well defined ranges for the normalization and energy dependence of the diffusion coefficient. (orig.)
2009-09-15
Energy Technology Data Exchange (ETDEWEB)
The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming ...
2007-07-01
Energy Technology Data Exchange (ETDEWEB)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that ...
2003-10-01
International Nuclear Information System (INIS)
In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection ...
2003-10-01
International Nuclear Information System (INIS)
The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.
Minimal Neutrino Beta Beam for Large theta_13
We discuss the minimum requirements for a neutrino beta beam if theta_13 is discovered by an upcoming reactor experiment, such as Double Chooz or Daya Bay. We require that both neutrino mass hierarchy and leptonic CP violation can be measured to competitive precisions with a single-baseline experiment in the entire remaining theta_13 range. We find that for very high isotope production rates, such as they might be possible using a production ring, a (B,Li) beta beam with a gamma as low as 60 could already be sufficient to perform all of these measurements. If only the often used nominal source luminosities can be achieved, for example, a (Ne,He) beta beam from Fermilab to a possibly existing water Cherenkov detector at Homestake with gamma \\sim 190-350 (depending on the Double Chooz best-fit) could outperform practically any other beam technology including wide-band beam and neutrino factory.
2008-01-01
Measurement of induced radioactivity in materials found around a neutron generator
The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)
1974-01-01
Energy Technology Data Exchange (ETDEWEB)
The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.
1985-03-01
La{sup 3+} modified Al{sub 2}O{sub 3} as a support for CeO{sub 2}
Energy Technology Data Exchange (ETDEWEB)
X-ray photoelectron spectroscopy measurements indicate that the Ce{sup 3+} like fraction in {gamma}-Al{sub 2}O{sub 3} supported CeO{sub 2} can be decreased by the incorporation of La{sup 3+}. If La{sup 3+} is incorporated into the {gamma}-Al{sub 2}O{sub 3} before CeO{sub 2} is added, a higher CeO{sub 2} dispersion and a greater range of reversible reducibility of the CeO{sub 2} may also be obtained. These changes offer potential for improvement in the oxygen storage capacity provided by CeO{sub 2} in three-way catalysts. The actual effect of La{sup 3+} incorporation on the activity and durability of a Pt catalyst is assessed by a combination of temperature programmed reduction and flow reactor measurements.
1993-12-31
Energy Technology Data Exchange (ETDEWEB)
Proton and alpha particle spectral shapes and multiplicities have been measured in coincidence with evaporation residues from {sup 28}Si+{sup 165}Ho and {sup 16}O + {sup 197}Au, {sup 208}Pb fusion reactions. Our experiments used 145 to 220 MeV {sup 28}Si and 115 and 140 MeV {sup 16}O beams produced with the Stony Brook LINAC. ER`s were separated using an electrostatic deflector and detected with large area surface barrier detectors. Light charged particles were detected at forward and backward angles with fourteen single NaI detectors. In the context of the statistical model, charged particle spectra yield information about emission barriers and compound nucleus equilibrium level densities. These are significant ingredients in calculations determining fission timescales from other observables such as pre-scission neutron multiplicities or fusion-evaporation excitation functions. Results will also be compared to analyses of pre-scission charged ...
1993-10-01
The influence of salt aerosol on alpha radiation detection by WIPP continuous air monitors
Energy Technology Data Exchange (ETDEWEB)
Alpha continuous air monitors (CAMs) will be used at the Waste Isolation Pilot Plant (WIPP) to measure airborne transuranic radioactivity that might be present in air exhaust or in work-place areas. WIPP CAMs are important to health and safety because they are used to alert workers to airborne radioactivity, to actuate air-effluent filtration systems, and to detect airborne radioactivity so that the radioactivity can be confined in a limited area. In 1993, the Environmental Evaluation Group (EEG) reported that CAM operational performance was affected by salt aerosol, and subsequently, the WIPP CAM design and usage were modified. In this report, operational data and current theories on aerosol collection were reviewed to determine CAM quantitative performance limitations. Since 1993, the overall CAM performance appears to have improved, but anomalous alpha spectra are present when sampling-filter salt deposits are at normal to high levels. This ...
1996-01-01
Inclusive K{sup +}-meson production in proton-nucleus interactions
Energy Technology Data Exchange (ETDEWEB)
The production of K{sup +}-mesons in pA(A=D,C,Cu,Ag,Au) collisions has been investigated at the COoler SYnchrotron COSY-Juelich for beam energies T{sub p}=1.0-2.3 GeV. Double differential inclusive pC cross-sections at forward angles {theta}{sub K+}<12 as well as the target mass dependence of the K{sup +} momentum spectra have been measured with the ANKE spectrometer. Far below the free NNthreshold at T{sub NN}=1.58 GeV the spectra reveal a high degree of collectivity in the target nucleus. From the target mass dependence of the cross-sections at higher energies, the repulsive in-medium potential of the K{sup +}-mesons can be deduced. Using pNcross-section parameterisations from the literature and our measured pD data we derive a cross-section ratio {sigma}(pn{yields}K{sup +}X)/{sigma}(pp{yields}K{sup +}X) {proportional_to}(3-4). (orig.)
2004-11-01
Energy Technology Data Exchange (ETDEWEB)
The coherent interaction of femtosecond laser pulses and a thin CdSe sample is investigated both experimentally and theoretically. Observation of coherent phenomena in semiconductors is very rare because the incoherent processes occur in the femtosecond time domain in these materials. One example of such a phenomena is the so called optical Stark effect of exciton where a blue shift of the exciton resonance occurs as a result of pumping below the bandgap. The coherent effects involving band-to-band and also exciton transitions. Using femtosecond transmission measurements clear evidence was observed for coherent interference effects of the light field and the driven material polarization. These interferences manifest themselves as oscillatory structures in the differential transmission spectra. The oscillatory features are explained by comparison with a semiclassical theory. Examples of the computed results are presented for different time ...
1987-01-01
EPR and FT-IR spectroscopic studies of Bi2O3-B2O3-CuO glasses
International Nuclear Information System (INIS)
EPR and FT-IR absorption measurements have been performed for xCuO.(100-x)[2Bi2O3.B2O3] glass system, with 0?x?50 mol%. The mode in which the addition of the copper ions influences the structure of 2Bi2O3.B2O3 glass matrix was analyzed. The EPR absorption spectra revealed the presence in the glass structure of Cu2+ ions in axially distorted octahedral environments. EPR data pointed out the simultaneous presence of Cu2+ and Cu+ ionic species in the glasses with x?5 mol%. For x>10 mol%, the Cu2+ ions participate in the superexchange magnetic interactions, which increase with CuO content. The FT-IR spectra showed the presence of some bands that are assigned to vibrations of Bi-O bonds from BiO3 pyramidal and BiO6 octahedral units and B-O bonds from BO3 and BO4 units. The data obtained by these measurements reveal the structural changes in the 2Bi2O3.B2O3 glass matrix by controlled doping of CuO.
2008-10-01
Energy Technology Data Exchange (ETDEWEB)
The fluxes of atmospheric electrons, positrons, positive and negative muons and negative pions have been determined using the NMSU Wizard-MASS2 balloons-borne instrument. The instrument was launched from Fort Sumner, New Mexico, (geomagnetic cut-off about 4.5 GV/c) on september 23, 1991. The flight lasted 9.8 hours and remained above 100.000 ft. Muons and negative pions were observed and their momenta were determined. Since these particles are not a part of the primary component, the measurement of their fluxes provides information regarding production and propagation of secondary particles in the atmosphere. Similarly, observations of electrons and positrons well below the geomagnetic cut-off provides insight into electromagnetic cascade processes in the upper atmosphere. In addition, the determination of the energy spectra of rare particles such as positrons can be used for background subtraction for cosmic ray experiments gathering data ...
1995-09-01
British Library Electronic Table of Contents (United Kingdom)
We performed experimental studies on the convolution/superposition method reported in the former companion paper (Iwasaki in Radiol Phys Technol 4, 2011) using 10-MV X-ray beams from open-jaw-collimated fields. The method uses primary and scatter dose kernels formed for energy bins of X-ray spectra reconstructed as a function of off-axis distance. We made a comparison of calculations and measurements in water phantoms and thorax-like phantoms with respect to percentage depth dose curves, tissue???phantom ratio curves, and dose profiles. We made the dose calculation by taking into account the beam-hardening effect with depth and the off-axis radiation-softening effect. We found that the method could be used, in general, for performing accurate dose calculations.
2011-01-01
Signatures of extra dimensions at e{gamma} and {gamma}{gamma} colliders
Energy Technology Data Exchange (ETDEWEB)
The authors study the processes {gamma}e {r{underscore}arrow} {gamma}e and {gamma}{gamma} {r{underscore}arrow} {gamma}{gamma}, in the context of the proposal for Weak Scale Quantum Gravity (WSQG) with large extra dimensions. With an ultraviolet cutoff M{sub S} {approximately} 1 TeV for the effective gravity theory, the cross sections obtained for these processes at the Next Linear Collider (NLC), with the e{gamma} an {gamma}{gamma} options, deviate from the predictions of the Standard Model significantly. The results suggest that, for typical proposed NLC energies and luminosities, the predictions of WSQG can be tested in the range 1 TeV {approx{underscore}lt} M{sub S} {approx{underscore}lt} 10 TeV, making e{gamma} an {gamma}{gamma} colliders important tools for probing WSQG.
2000-01-26
The Galactic Center Region Gamma Ray Excess from A Supersymmetric Leptophilic Higgs Model
In a recent paper by Hooper and Goodenough, data from the Fermi Gamma Ray Telescope was analyzed and an excess of gamma rays was found in the emission spectrum from the Galactic Center Region. Hooper and Goodenough show that the excess can be well explained by 7-10 GeV annihilating dark matter with a power law density profile if the dark matter annihilates predominantly to tau pairs. In this paper we present such a dark matter model by extending the MSSM to include four Higgs doublets and one scalar singlet. A Z2 symmetry is imposed that enforces a Yukawa structure so that the up quarks, down quarks, and leptons each receive mass from a distinct doublet. This leads to an enhanced coupling of scalars to leptons and allows the model to naturally achieve the required phenomenology in order to explain the gamma ray excess. Our model yields the correct dark matter thermal relic density and avoids collider bounds from ...
2011-01-01
T=(5/2) "2"7Na from "1"4C+"1"4C, and the N=16 shell gap
International Nuclear Information System (INIS)
For the first time a comprehensive level and decay scheme has been obtained for a T=(5/2) nucleus in the s-d shell ("2"7Na) by using a radioactive beam and target. Particle-#gamma# and p-#gamma#-#gamma# coincidences were measured following the "1"4C("1"4C,p#gamma#)"2"7Na reaction at E_l_a_b=22 MeV. The results do not support an inversion of the 2s_1_/_2 and 1d_5_/_2 orbitals, as previously proposed for T_z#>=#3, but they do suggest an increased N=16 gap between the 2s_1_/_2 and 1d_3_/_2 orbitals due to the neutron excess. A consistent interpretation of the level scheme in terms of the s-d shell model using the USD Hamiltonian is possible below 4 MeV, but differences increase at higher excitation energies. Another interpretation is that the influences of both the p_1_/_2 and f_7_/_2 intruder orbitals increase simultaneously with increasing T, an effect not included in the USD Hamiltonian.
2002-05-01
Energy Technology Data Exchange (ETDEWEB)
Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma ...
2004-07-01
International Nuclear Information System (INIS)
Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight ...
International Nuclear Information System (INIS)
Phase transformations in TiD_#approx#_0_._7_5 subjected to high-pressure treatment were investigated by simultaneous real-time measurements of neutron diffraction and small-angle neutron scattering. The neutron spectra were taken on heating the samples in temperature ranges 100 to 300 K and 300 to 870 K. A sequence of structural transitions was observed, which involves 7 different phases and intermediate states with hcp, fcc, fco or bcc metal sublattices and hydrogen atoms. 30 refs., 9 figs., 1 tab.
1992-09-01
Real time neutron transmission investigation of the austenite-bainite transformation in grey iron
Energy Technology Data Exchange (ETDEWEB)
The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.))
1994-06-01
Real time neutron transmission investigation of the austenite-bainite transformation in grey iron
International Nuclear Information System (INIS)
The first successful application of a new method to investigate phase transformations in real time, like the decomposition of austenite into bainite in grey iron, is described. During the ongoing transformation, transmission spectra of thermal neutrons, which contain Bragg edges corresponding to the crystal structure of the transforming phases, are recorded. By evaluating the height of these Bragg edges, which is a measure of the volume fraction of the phase, at different transformation times, the transformation can be followed in-situ in a time resolved manner. The method is compared to other previously used methods (micrographs, dilatometry, diffraction techniques); also a summary and an outlook are given. ((orig.)).
1994-01-01
International Nuclear Information System (INIS)
Several new complexes of isomeric schiff bases derived from salicylaldehyde and o-hydroxybenzylamine/o-aminobenzyl-alcohol with Pr(III), Nd(III), Sm(III), Gd(III), Tb(III), and Dy(III) have been synthesized and characterized by elemental analysis, molar conductance, IR, electronic spectra and magnetic susceptibility measurements. The schiff bases behave as monobasic tridentate ONO donor and dibasic tridentate ONO donor ligands and form complexes of the type Ln(LH)L. (author). 12 refs.
1988-01-01
Ion beam crystallography of metal-silicon interfaces: Pd-Si(111)
Energy Technology Data Exchange (ETDEWEB)
The application of medium energy ion scattering in combination with channelling and blocking to the study of the initial stages of palladium silicide formation is discussed. After a brief description of the experimental arrangement and method, the effects on the Rutherford backscattering spectra of depositing small quantities of palladium on clean Si(111) are reported. The uniformity and thermal stability of thin palladium silicide films grown at room temperature were measured. Finally, channelling and blocking results were used to carry out a structural analysis of thin epitaxial Pd/sub 2/Si layers.
1982-07-09
Ion beam crystallography of metal-silicon interfaces: Pd-Si(111)
International Nuclear Information System (INIS)
The application of medium energy ion scattering in combination with channelling and blocking to the study of the initial stages of palladium silicide formation is discussed. After a brief description of the experimental arrangement and method, the effects on the Rutherford backscattering spectra of depositing small quantities of palladium on clean Si(111) are reported. The uniformity and thermal stability of thin palladium silicide films grown at room temperature were measured. Finally, channelling and blocking results were used to carry out a structural analysis of thin epitaxial Pd_2Si layers. (Auth.).
Interpretation of EXAFS data from laser shock compressed plasmas
Energy Technology Data Exchange (ETDEWEB)
Measurements on laser shock compressed aluminium using the EXAFS (Extended X-ray Absorption Fine Structure) technique on the Al K-edge are described. Two methods of analysis of this data were used for the determination of density: the standard EXAFS technique using Fourier transforms and curve fitting, and a method based on a bandstructure calculation of the absorption spectra as a function of compression. These two techniques give results which are in fairly good agreement with each other and also with a hydrodynamic simulation of the experiment. The ion correlation parameter is estimated and shows that two-sided laser irradiation of aluminium foils produces a dense plasma which is strongly coupled. (author).
1989-01-01
PAMELA is a space telescope orbiting around the Earth since June 2006. The scientific objectives addressed by the mission are the measurement of the antiprotons and positrons spectra in cosmic rays, the hunt for anti-nuclei as well as the determination of light nuclei fluxes from Hydrogen to Oxygen in a wide energy range and with very high statistics. In this paper the charge discrimination capabilities of the PAMELA Time-Of-Flight system for light nuclei, determined during a beam test calibration, will be presented.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
Alpha particles, tritons, deuterons and protons accompanying /sup 252/Cf fission were registered in coincidence with both fission fragments by means of a system containing two-dimensional position-sensitive silicon detectors. Angular distributions, kinetic energy spectra of light charged particles as well as mass distributions of fission fragments in coincidence with light charged particles were measured. The experimental results are compared with some theoretical models.
1985-06-03
3. Physical foundations and methodology of radionuclide X-ray fluorescence analysis
International Nuclear Information System (INIS)
The physical foundations are described of radionuclide X-ray fluorescence analysis (RXFA) and the table shows the values of K- and L-absorption thresholds and the K- and L-line energies of elements. The calculation of the intensity of characteristic radiation during RXFA proceeds from relations derived for conventional X-ray fluorescence analysis. The choice of the radionuclide source is ruled by the nature of the analysed substance and the used detection technique. The diagram shows the areas of radionuclide sources and the energy of the fluorescence radiation of elements. The table shows the spectra of radionuclide sources suitable for the purposes of RXFA measured by semiconductor Si(Li) and Ge(Li) detectors. (ES).
1983-12-01
The utility of recording Raman spectroscopy under liquid nitrogen, a technique we call Raman Under Nitrogen (RUN), is demonstrated for ferrocene, uranocene and thorocene. Using RUN, low temperature (liquid nitrogen cooled) Raman spectra for these compounds exhibit higher resolution than previous studies and new vibrational features are reported. The first Raman spectra of crystalline uranocene at 77 K are reported using excitation from argon (5145 ) and krypton (6764 ) ion lasers. The spectra obtained showed bands corresponding to vibrational transitions at 212, 236, 259, 379, 753, 897, 1500, and 3042 cm-1 , assigned to ring-metal-ring stretching, ring-metal tilting, out-of-plane CCC bending, in-plane CCC bending, ring-breathing, C-H bending, CC stretching and CH stretching, respectively. The assigned vibrational bands are compared to those of uranocene in THF and thorocene. All vibrational frequencies of the ligands, ...
2004-02-08
International Nuclear Information System (INIS)
The utility of recording Raman spectroscopy under liquid nitrogen, a technique we call Raman Under Nitrogen (RUN), is demonstrated for ferrocene, uranocene and thorocene. Using RUN, low temperature (liquid nitrogen cooled) Raman spectra for these compounds exhibit higher resolution than previous studies and new vibrational features are reported. The first Raman spectra of crystalline uranocene at 77 K are reported using excitation from argon (5145 ) and krypton (6764 ) ion lasers. The spectra obtained showed bands corresponding to vibrational transitions at 212, 236, 259, 379, 753, 897, 1500, and 3042 cm-1 , assigned to ring-metal-ring stretching, ring-metal tilting, out-of-plane CCC bending, in-plane CCC bending, ring-breathing, C-H bending, CC stretching and CH stretching, respectively. The assigned vibrational bands are compared to those of uranocene in THF and thorocene. All vibrational frequencies of the ligands, ...
2004-02-08
Energy Technology Data Exchange (ETDEWEB)
Point-contact (PC) investigations on the title compound in the normal and superconducting (SC) state (T{sub c}{approx_equal}10.6 K) are presented. The T-dependence of two SC gaps in TmNi{sub 2}B{sub 2}C determined by Andreev-reflection spectroscopy deviates from the BCS behavior in displaying a maximum at about T{sub c}/2. Additional evidence for the presence of a 2nd gap half as large as the main gap is given. For the first time ''reentrant'' features were found in the Andreev-reflection spectra measured in magnetic fields. The PC spectroscopy of the fermion-boson interaction in TmNi{sub 2}B{sub 2}C reveals a pronounced phonon maximum at 9.5 meV and a more smeared one around 15 meV, while at higher energies the PC spectra are almost featureless. Additionally, the intense peak slightly above 3 meV observed in the PC spectra of TmNi{sub 2}B{sub 2}C, is presumably ...
2009-07-01
Enhanced spectral discrimination through the exploitation of interface effects in photon dose data
International Nuclear Information System (INIS)
The convolution/superposition algorithm for computing dose from photon beams in radiation therapy planning requires knowledge of the energy spectrum. The algorithm can compute the dose for a polyenergetic beam as the weighted sum of the individual dose contributions from monoenergetic beams. In this study we exploit interface effects apparent in the dose distributions to discriminate among spectra of high energy photon beams. We have studied the sensitivity of the depth dose distribution to the energy components using a hypothetical beam for various field sizes and depths in water and water-lung-water media. Six theoretical spectra were simulated. We compared depth dose data from these spectra using three quantitative measures which are inherently free of normalization ambiguities: for homogeneous water, the ratio D_2_0/D_1_0 and a logarithmic derivative in the buildup region LD_b_u_i_l_d_-_u_p and for ...
2004-02-01
International Nuclear Information System (INIS)
Complete energy spectra and angular distributions of the light charged particles (A < or = 4) were measured for the bombardment of "2"7Al, "5"8Ni, "9"0Zr, "2"0"9Bi, and "2"3"2Th with 140 MeV #alpha# particles. The spectral shapes of a given emitted particle are very similar for all target nuclei except in the region of the evaporation peak. The slopes of the energy spectra in the forward direction become steeper as the mass of the observed particle decreases and vary very rapidly with angles. The experimental data can be characterized by compound nuclear evaporation processes at low energies, or at backward angles, and by direct reactions, nonequilibrium components and projectile breakup processes at high energies and forward angles. The breakup cross section for #alpha# particles is found to be appreciable. The total yield of light charged particles is approximately a factor approx. 2 to 3 larger than the total reaction ...
Safe detection of Co-60. New perspectives in contamination and clearance measurements
International Nuclear Information System (INIS)
Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. ...
The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters
Energy Technology Data Exchange (ETDEWEB)
The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not been reported previously, whereas in the case of SEI glass, there exists a modest body of previous work on ...
1990-01-01
The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters
International Nuclear Information System (INIS)
The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not been reported previously, whereas in the case of SEI glass, there exists a modest body of previous work on ...
Energy Technology Data Exchange (ETDEWEB)
A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical ...
2010-05-01
Probing of the Higgs-fermion coupling at. gamma. gamma. -colliders
Energy Technology Data Exchange (ETDEWEB)
Three possibilities to observe the Higgs-top interaction at future {gamma}{gamma}-colliders are discussed: (a) associated Higss production via the {gamma}{gamma}{yields}tanti tH reaction, (b) Higgs obliged radiative correction to the {gamma}{gamma}{yields}tanti t channel, (c) Higgs resonance production via {gamma}{gamma}{yields}H{yields}ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at {gamma}{gamma}-colliders. (orig.).
1992-11-01
Probing of the Higgs-fermion coupling at #gamma##gamma#-colliders
International Nuclear Information System (INIS)
Three possibilities to observe the Higgs-top interaction at future #gamma##gamma#-colliders are discussed: a) associated Higss production via the #gamma##gamma##->#tanti tH reaction, b) Higgs obliged radiative correction to the #gamma##gamma##->#tanti t channel, c) Higgs resonance production via #gamma##gamma##->#H#->#ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at #gamma##gamma#-colliders. (orig.).
Development of a phoswich detector to detect neutrons in the charged-particle mixed field
Energy Technology Data Exchange (ETDEWEB)
Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, ...
1997-07-01
Proceedings of the first meeting on e{gamma}/{gamma}{gamma} colliders
Energy Technology Data Exchange (ETDEWEB)
The first meeting on e{gamma}/{gamma}{gamma} colliders was held on September 28 and 29, 1993, at the National Laboratory for High Energy Physics. After general remarks were delivered, lectures were given on QED in intense laser field, photon linear collider, laser focusing, luminosity distribution in the e{gamma}/{gamma}{gamma} colliders, QCD correction for {gamma}{gamma}{yields}H, radiation correction for e{gamma}/{nu}W process, SUSY particle production at the e{gamma} and {gamma} gamma colliders, formation of e{sup *} in e{gamma} collision, and general remarks on the theory. Discussion was carried out on `Where are we going from here?` In this book, the gists of the lectures are collected. (K.I.).
1994-01-01
Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array
The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a ...
2009-03-10
An aerial radiological survey of the Portsmouth Gaseous Diffusion Plant and surrounding area
International Nuclear Information System (INIS)
An aerial radiological survey was conducted from August 10-16, 1993, over a 78-square-kilometer (30-square-mile) area of the Portsmouth Gaseous Diffusion Plant and surrounding area located near Portsmouth, Ohio. The survey was performed at a nominal altitude of 46 meters (150 feet) with a line spacing of 76 meters (250 feet). A contour map of the terrestrial gamma exposure rate extrapolated to 1 meter above ground level was prepared and overlaid on a set of United States Geological Survey topographic maps of the area and an aerial photograph of the plant. The terrestrial gamma exposure rates varied from about 7 to 14 microroentgens per hour at 1 meter above the ground. Protactinium-234m was observed at six sites within the boundaries of the plant. At a seventh site, only uranium-235 was observed. No other man-made, gamma ray-emitting radioactive material was present in a detectable quantity, either on or off the plant ...
2005-05-01
[Fast neutron cross section measurements]. Progress report
Energy Technology Data Exchange (ETDEWEB)
In this report, we outline the progress achieved in two distinct under the DOE-sponsored cross section project: the initial results obtained from the pulsed 14 MeV neutron facility, and a cooperative effort with Argonne National Laboratory in the measurement of fast neutron cross sections in yttrium. In the 14 MeV neutron laboratory, this year has seen the maturation of the project into one in which initial scattering measurements are now underway. We have improved the accelerator and ion source in several significant ways, so that neutron intensities have now been proven to be adequate for our series of elastic scattering angular distribution measurements outlined in our initial proposal of two years ago. We have successfully tested all components of the time-of-flight spectrometer and recorded initial neutron spectra from the ring targets that we have obtained for our first angular distribution ...
1991-12-31
The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core
Energy Technology Data Exchange (ETDEWEB)
This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in ...
2006-07-15
Energy Technology Data Exchange (ETDEWEB)
The computer program is developed based on Visual C++, which is equipped with a user-friendly interface of the input/output(I/O) and a display function for the measuring conditions. This program consists of three parts which are the port communication, PLC(Programmable Logic Controller) and the MCA(Multi Channel Analyzer) control parts. The communication type between the CPU of the PLC module box and the computer is selected as be the Rs-232 asynchronous type and the thread method is adapted in the development of the first part of the program. The PLC-related program has been developed so that the data communication between the PLC CPU and the computer could be harmonized with the unique commands which have already been defined in the PLC. The measuring space and time intervals, the start and end ROI(region of interest) values, and the allowable error limitation are input at each measurement in this program. Finally the ...
2005-11-15
Width of the 1. 836-MeV level in /sup 88/Sr
Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2/sup +//sub 1/ level in /sup 88/Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.
1977-06-01
The triaxial motion in Mo isotopes
Energy Technology Data Exchange (ETDEWEB)
The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of [sup 87]Mo are studied in detail and explained by the evolution of the [gamma]-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N [>=] 47 for the spherical shape of the Mo isotopes. (orig.)
1993-11-22
The triaxial motion in Mo isotopes
International Nuclear Information System (INIS)
The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of "8"7Mo are studied in detail and explained by the evolution of the #gamma#-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N #>=# 47 for the spherical shape of the Mo isotopes. (orig.).
Tests for mutagencity of free radicals formed in irradiated sugars and amino acids
International Nuclear Information System (INIS)
Radicals formed in gamma-irradiated crystals of galactose and glycine were found, upon dissolution, to cause mutagenesis of Salmonella typhimurium strains TA-98 and TA-100. Although the reproducibility of the results has not been adequately determined, they suggest the possibility of developing a test to measure the mutagenic-carcinogenic potential of radiation-induced free radicals with a microbial system.
1977-05-01
International Nuclear Information System (INIS)
The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.
Radiation treatment of some poultry products
International Nuclear Information System (INIS)
Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.
1988-09-26
International Nuclear Information System (INIS)
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.
2006-06-12
In-beam conversion electron spectroscopy using the SACRED array
International Nuclear Information System (INIS)
Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.
Evaluation of radiation resistance of cable connector material
Energy Technology Data Exchange (ETDEWEB)
Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.
2002-10-01
UK PubMed Central (United Kingdom)
The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available
1994-05-01
Anomalous solvent extraction behavior of astatine
International Nuclear Information System (INIS)
We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).
Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors
Energy Technology Data Exchange (ETDEWEB)
A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.)
1993-10-01
Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors
International Nuclear Information System (INIS)
A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.).
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
Energy Technology Data Exchange (ETDEWEB)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. ...
2007-11-15
A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia
International Nuclear Information System (INIS)
The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate ...
2007-11-01
Modification of SGS system for application to various sized drums
Energy Technology Data Exchange (ETDEWEB)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is ...
2005-11-15
Modification of SGS system for application to various sized drums
International Nuclear Information System (INIS)
To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % and that of SGS is ...
2005-11-01
International Nuclear Information System (INIS)
A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurement results is also studied. The measurement results of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The uncertainty of measurement results for uranium and plutonium ...
1998-09-01
Application od scaling technique for estimation of radionuclide inventory in radioactive waste
International Nuclear Information System (INIS)
Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and TRUs. The measurements ...
1996-09-16
British Library Electronic Table of Contents (United Kingdom)
Purpose Ultraviolet-B (UV-B) radiation can cause phototoxic macular injuries in young people who have been sunbathing but not sungazing and in welders. Welders have a reportedly increased risk of uveal melanoma. We analyze phakic and pseudophakic risks for solar and welding arc UV-B exposure. Design Optical radiation measurement, analysis, and perspective. Methods Spectral transmittances were measured for UV-transmitting, UV-blocking, and blue-blocking intraocular lenses (IOLs). The photoprotective performances of crystalline and intraocular lenses were analyzed using relevant epidemiologic and laboratory data and action spectra for acute retinal phototoxicity and melanoma photocarcinogenesis. Results Crystalline lens UV-B retinal protection is deficient in children and young adults, incre...
2010-01-01
Proton emission in reaction of 14.6 MeV neutrons with natural iron
Energy Technology Data Exchange (ETDEWEB)
The energy spectra and angular distributions of proton emission in a reaction of {sup nat}Fe(n,xp) at a neutron energy of 14.6 MeV are measured by the University of Science and Technology of China multitelescope system. The double-differential cross sections of 16 reaction angles from 25 to 164.5 deg are obtained in this measurement. The statistical errors are reduced largely because of the thick target used. The angular distributions show a slightly energy-dependent forward-backward asymmetry. The angle-integrated proton spectrum is compared with theoretical calculations and other results. The total proton-emission cross section is in fair agreement with the prediction and evaluation.
1996-01-01
Non-standard antineutrino interactions at Daya Bay
We study the prospects of pinning down the effects of non-standard antineutrino interactions in the source and in the detector at the Daya Bay neutrino facility. It is well known that if the non-standard interactions in the detection process are of the same type as those in the production, their net effect can be subsumed into a mere shift in the measured value of the leptonic mixing angle theta_13. Relaxing this assumption, the ratio of the antineutrino spectra measured by the Daya Bay far and near detectors is distorted in a characteristic way, and good fits based on the standard oscillation hypothesis are no longer viable. We show that, under certain conditions, three years of Daya Bay running can be sufficient to provide a clear hint of non-standard neutrino physics.
2011-01-01
Measurements of vibrational excitation of N_2, CO, and NO by low energy proton impact
International Nuclear Information System (INIS)
Differential scattering experiments are reported for proton impact on N_2, CO, and NO in the energy range E/sub lab/=30--80 eV. The measurements include the range of very small scattering angles around 0"0 as well as the rainbow region. The vibrationally resolved energy-loss spectra show a relatively low vibrational inelasticity for all three systems. Differential cross sections, transition probabilities, and the mean vibrational energy transfer are presented. Rotational excitation is indicated by the broadening of the energy-loss peaks which is most significant for H"+--NO. The small-angle scattering data for vibrational excitation in CO show good agreement with the impact parameter theory using the known long-range interactions for this system.
1979-07-01
Magnetic properties of ErPd_2Si_2 from magnetization Moessbauer and neutron diffraction measurements
International Nuclear Information System (INIS)
Magnetization, neutron diffraction and "1"6"6Er Moessbauer measurements on ErPd_2Si_2 are reported. Below 4.8 K ErPd_2Si_2 orders AF with complex modulated magnetic structures, where the Er moments are aligned along the c-axis. At 1.5 K a squared structure with #mu#_E_r #approx# 7.8(1)#mu#_B is found while a saturation Er moment of 8.2(2)#mu#_B is inferred from the hyperfine field data. The temperature dependence of the Moessbauer spectra in the paramagnetic region is explained in the framework of a relaxation model implying excited crystal field levels. Its analysis is used to estimate the B"m_n CEF parameters. (orig.).
The authors have studied (Al{sub x}Ga{sub 1{minus}x}){sub 0.5}In{sub 0.5}P doped with tellurium using deep level transient spectroscopy and associated electrical measurements. Several defect states are observed in the upper half of the band gap, that are believed to be intrinsic to the alloy system as well as related to the tellurium donors. Defects observed at measurement temperatures above 390 K exhibit a hysteretic behavior. The observed spectra depend on the biasing conditions applied to the Schottky diode during cooling. The hysteretic behavior suggests the existence of different defect configurations, which can be accessed under conditions of high temperatures and electrical stress, but remain stable below 300 K.
2000-02-01
Energy Technology Data Exchange (ETDEWEB)
The authors have studied (Al{sub x}Ga{sub 1{minus}x}){sub 0.5}In{sub 0.5}P doped with tellurium using deep level transient spectroscopy and associated electrical measurements. Several defect states are observed in the upper half of the band gap, that are believed to be intrinsic to the alloy system as well as related to the tellurium donors. Defects observed at measurement temperatures above 390 K exhibit a hysteretic behavior. The observed spectra depend on the biasing conditions applied to the Schottky diode during cooling. The hysteretic behavior suggests the existence of different defect configurations, which can be accessed under conditions of high temperatures and electrical stress, but remain stable below 300 K.
2000-02-01
A study of the B 24 - A 19 transition of benzene molecule in different matrices
International Nuclear Information System (INIS)
Ultraveiolet spectroscopy of molecules in vapour phase gives valuable information about electronic structure of free molecules. But in many cases vaipour phase investigations are not possible and in order to isolate molecules within solid lattice, we used cryogenic temperature and high vacuum technology to study absorption spectrum within the spectral range (230-270)nm of an isolated benzene molecule in Argon, Krpton, Nitrogen, Carbon and methane matrices. The spectra shifts were measured and calculated in the matrix environment for the electronnic transition (B 24--A 19) in benzene molecule using the matrices mentioned above. Molar extinction coefficients and oscillator strength were measured too. (7 tabs., 32 figs., 50 refs.).
1988-01-01
The ''nuclear car wash'': a scanner to detect illicit special nuclear material in cargo containers
International Nuclear Information System (INIS)
There is an urgent need to improve the reliability of screening cargo containers for illicit nuclear material that may be hidden there for terrorist purposes. A screening system is described for detection of fissionable material hidden in maritime cargo containers. The system makes use of a low intensity neutron beam for producing fission; and the detection of the abundant high-energy #gamma# rays emitted in the #beta#-decay of short-lived fission products and #beta#-delayed neutrons. The abundance of the delayed #gamma# rays is almost an order of magnitude larger than that of the delayed neutrons normally used to detect fission and they are emitted on about the same time scale as the delayed neutrons, i.e., #approx#1 min. The energy and temporal distributions of the delayed #gamma# rays provide a unique signature of fission. Because of their high energy, these delayed #gamma# rays penetrate loW--Z ...
2004-01-28
International Nuclear Information System (INIS)
The Gamma Physics (GaP) program of physical phenomena investigation is proposed on #gamma#p, #gamma#e and #gamma##gamma# colliders at TeV energies. The program contains specialized software (CompHEP system) created for automation of particle interaction processes calculations in the framework of various gauge models. Preliminary physical results are presented (heavy quark production, W, Z production, supersymmetry etc.), and further software development is suggested. (R.P.) 22 refs., 8 figs., 4 tabs.
Energy Technology Data Exchange (ETDEWEB)
A procedure and software have been developed to transform the area distribution of the residual surface heights available from the measurement with the Micromap interferometric microscope into a two-dimensional (2D) power spectral density (PSD) distribution of the surface height. The procedure incorporates correction of one of the spectral distortions of the PSD measurement. The distortion appears as a shape difference between the tangential and sagittal PSD spectra deduced from the 2D PSD distribution for an isotropic surface. A detailed investigation of the origin of the anisotropy was performed, and a mathematical model was developed and used to correct the distortion. The correction employs a modulation transfer function (MTF) of the detector deduced analytically based on an experimentally confirmed assumption about the origin of the anisotropy due to the asymmetry of the read-out process of the instrument's ...
2005-05-12
Variations in skin perfusion are easily detected by laser speckle contrast maps, but a robust interpretation of the information has been lacking. We show that multiple-exposure laser speckle methods produce the same spectral information as laser Doppler methods when applied to targets with embedded moving scatterers. This enables laser speckle measurements to be interpreted more quantitatively. We do this by using computer simulation of speckle data, and by experimental measurements on Brownian motion and skin perfusion using a laser Doppler system and a multiple-exposure laser speckle system. The power spectral density measurements of the light fluctuations derived using both techniques are exactly equivalent. Dermal perfusion can therefore be measured by laser Doppler or laser speckle contrast methods. In particular, multiexposure laser speckle can be rapidly processed to generate a full-field map of ...
2010-03-01
Solution of the orthopositronium lifetime puzzle
The intrinsic decay rate of orthopositronium formed in SiO/sub 2/ powder is measured using the direct 2 gamma correction method such that the time dependence of the pick-off annihilation rate is precisely determined. The decay rate of orthopositronium is found to be 7.0396+or-0.0012(stat.)+or-0.0011(sys.)/ mu s/sup -1/, which is consistent with our previous measurements with about twice the accuracy. Results agree well with the O( alpha /sup 2/) QED prediction, and also with a result reported very recently using nanoporous film.
2004-01-01
Moessbauer diffraction measurements on polycrystalline bcc iron
Energy Technology Data Exchange (ETDEWEB)
In the early days of Moessbauer spectroscopy, it was demonstrated that coherent scattering of photons emitted by a Moessbauer source can be observed. In spite of the fact that scattering experiments could give information not accessible by the absorption method, they are not widely used. The reasons for this are, on the one hand, experimental difficulties, and on the other hand, the form of the samples, which should be large single crystals in most cases. In this work, we present a Moessbauer diffraction measurement on polycrystalline bcc iron where these problems have been overcome. We demonstrate that using the kinematical theory of gamma-ray diffraction, useful information on the relative orientation of the crystallographic axis to the hyperfine field directions can be subtracted. (orig.)
1994-11-01
Energy Technology Data Exchange (ETDEWEB)
This paper presents calculations of the {sup 252}Cf-source-driven noise analysis measurements for subcritical highly enriched uranium metal cylinders using the Monte Carlo code MCNP-DSP. This code directly calculates the noise analysis data from the {sup 252}Cf- source-driven noise analysis method for both neutron and gamma ray detectors. Direct calculation of experimental observables by the Monte Carlo method allows for the benchmarking of the calculational model and the cross sections and for determining the bias in the calculation.
1995-07-01
International Nuclear Information System (INIS)
The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.
Energy Technology Data Exchange (ETDEWEB)
Neutron capture cross sections of actinides are of great relevance for the Transmutation of Nuclear Waste in Accelerator Driven Systems (ADS) and Generation-IV reactors. The neutron capture cross sections of {sup 237}Np and {sup 240}Pu in the range of 1 eV to 2 keV were measured at the n-TOF facility with a Total Absorption Calorimeter. The data have been analyzed with the SAMMY code. The corresponding covariance matrices have been generated. The final cross sections are presented and compared to the previously existing ones.The n-TOF {sup 237}Np {sigma}(n,{gamma}) is in agreement with the evaluated data files below 300 eV and its is lower by 10 to 15% up to 2 keV. This discrepancy with the evaluated data files is also observed in the capture cross section derived from the transmission measurements of Gressier et al. In the case of the {sup 240}Pu {sigma}(n,{gamma}), the n-TOF ...
2008-07-01
A spatial sensitivity analysis technique for neutron and gamma-ray measurements
International Nuclear Information System (INIS)
In the fields of medical imaging, geophysical well logging, and industrial radiography, it is often of interest to characterize the spatially distributed sensitivities of neutron and gamma-ray measurement devices to the physical properties of the materials being examined. For instance, one may wish to know how the count rate in a detector varies in response to small changes in the local density of the irradiated object as a function of position. Experimental determination of such sensitivity functions is often impractical. Consequently, we have developed a general three-dimensional Monte Carlo numerical technique that allows us to directly compute the differential sensitivity of an arbitrary integral response parameter, such as a time- or energy-discriminated count rate, with respect to the spatial distribution of macroscopic cross sections and sources in the irradiated medium. Sensitivities to object density, porosity, etc., can easily be ...
1992-09-08
International Nuclear Information System (INIS)
In the convolution/superposition algorithm, the energy spectrum should be modified to make the reconstructed dose distribution consistent with the measured dose distribution. The energy spectrum, which gives the best agreement, is not determined uniquely depending on the reconstruction procedure. In this report, the effects of the characteristics of the energy spectrum on the calculation accuracy are evaluated by comparing the percentage depth dose (PDD) and beam profiles for the reference energy spectrum with those calculated for the modified spectrum in order to optimize the energy spectrum modification procedure when 4 and 10 MV X-ray beams are used. Decreasing the number of energy bins brought a larger decrease rate in the computation accuracy than a decrease rate in computation time. Further, the decrease of the number of energy bins led to a change of the energy spectrum. The balance of the relative fluence weight in a each bin and its average energy, which ...
2003-06-01
Energy Technology Data Exchange (ETDEWEB)
ICP emission analyses are prone to errors due to changes in power level, nebulization rate, plasma temperature, and sample matrix. As a result, accurate analyses of complex samples often require frequent bracketing with matrix matched standards. Information needed to track and correct the matrix errors is contained in the emission spectrum. But most commercial software packages use only the analyte line emission to determine concentrations. Changes in plasma temperature and the nebulization rate are reflected by changes in the hydrogen line widths, the oxygen emission, and neutral ion line ratios. Argon and off-line emissions provide a measure to correct the power level and the background scattering occurring in the polychromator. The authors` studies indicated that changes in the intensity of the Ar 404.4 nm line readily flag most matrix and plasma condition modifications. Carbon lines can be used to monitor the impact of organics on the analyses and calcium and ...
1997-10-01
Energy Technology Data Exchange (ETDEWEB)
Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO[sub 2] absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the [ital P] branch of the fundamental absorption band (2150--1950 cm[sup [minus]1]) while the CO[sub 2] vibrational-rotational lines were from the far wing of the [ital R] branch of the [nu][sub 3] fundamental band (2395--2380 cm[sup [minus]1]). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO[sub 2]/N[sub 2] gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite ...
1994-11-01
International Nuclear Information System (INIS)
Fourier transform infrared absorption spectroscopy has been used for the determination of the line strengths of 41 CO and CO_2 absorption lines at temperatures between 295 and 1250 K. The CO vibrational-rotational lines were from the P branch of the fundamental absorption band (2150--1950 cm"-"1) while the CO_2 vibrational-rotational lines were from the far wing of the R branch of the #nu#_3 fundamental band (2395--2380 cm"-"1). The intensities of the lines were measured from absorption spectra recorded in a high-temperature gas cell containing known concentrations of CO/CO_2/N_2 gas mixtures at atmospheric pressure. Absorption spectra were recorded through the cell with the use of a moderate-resolution Fourier transform infrared spectrometer. The absorption spectra were mathematically corrected for distortions resulting from the finite resolution of the spectrometer and for peak overlap. Line strength ...
Energy Technology Data Exchange (ETDEWEB)
Spectroscopic constants and absolute intensities from more than 2150 transitions belonging to 52 bands of 7 isotopic species of carbon dioxide have been determined using a multispectrum nonlinear least-squares fitting technique. The spectral data (0.01 cm{sup -1} resolution) were obtained at room temperature and low pressure (<10 Torr) using the McMath-Pierce Fourier transform spectrometer of the National Solar Observatory on Kitt Peak, Arizona. A natural sample of carbon dioxide with absorption path lengths between 24 and 385m were used in recording the spectra. The first measurements have been made of the theoretically predicted 2v{sub 2}{sup 2} 2+v{sub 3} {open_quotes}forbidden{close_quotes} band of {sup 12}CO{sub 2}. Two bands which have not been predicted so far, one belonging to {sup 13}CO{sub 2} and the other to {sup 13}C{sup 16}O{sup 18}O, have been identified. The measured line intensities obtained for each band ...
1995-12-31
Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks
Energy Technology Data Exchange (ETDEWEB)
Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of {sup 226}Ra and {sup 232}Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)
1999-07-01
Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks
International Nuclear Information System (INIS)
Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of "2"2"6Ra and "2"3"2Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)
Measurement of radon daughter product burden by TLD dosemeters
International Nuclear Information System (INIS)
A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.
Energy Technology Data Exchange (ETDEWEB)
Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.
1998-01-01
Study of Bs-> \\phi l^+ l^-$ Decay in a Single Universal Extra Dimension
Utilizing form factors calculated within the light-cone sum rules, we have evaluated the decay branching ratios of $B_s\\to \\phi\\gamma$ and $B_s\\to \\phi \\ell^+\\ell^-$ in a single universal extra dimension model (UED), which is viewed as one of the alternative theories beyond the standard model (SM). For the decay $B_s \\to \\phi \\ell^+\\ell^-$, the dilepton invariant mass spectra, the forward-backward asymmetry, and double lepton polarization are also calculated. For each case, we compared the obtained results with predictions of the SM. In lower values of the compactification factor 1/R, the only parameter in this model, we see the considerable discrepancy between the UED and SM models. However, when 1/R increases, the results of UED tend to diminish and at $1/R = 1000 \\mathrm{GeV}$, two models have approximately the same predictions. Compared with data from CDF of $B_s \\to \\phi \\mu^+ \\mu^-$, the 1/R tends to be larger than $350 ...
2011-01-01
Sequence of Potentials Lying Between the U(5) and X(5) Symmetries
Starting from the original collective Hamiltonian of Bohr and separating the beta and gamma variables as in the X(5) model of Iachello, an exactly soluble model corresponding to a harmonic oscillator potential in the beta-variable (to be called X(5)-$\\beta^2$) is constructed. Furthermore, it is proved that the potentials of the form $\\beta^{2n}$ (with n being integer) provide a ``bridge'' between this new X(5)-$\\beta^2$ model (occuring for n=1) and the X(5) model (corresponding to an infinite well potential in the beta-variable, materialized for n going to infinity. Parameter-free (up to overall scale factors) predictions for spectra and B(E2) transition rates are given for the potentials $\\beta^2$, $\\beta^4$, $\\beta^6$, $\\beta^8$, corresponding to E(4)/E(2) ratios of 2.646, 2.769, 2.824, and 2.852 respectively, compared to the E(4)/E(2) ratios of 2.000 for U(5) and 2.904 for X(5). Hints about nuclei showing this behaviour, as well as ...
2004-01-01
Energy Technology Data Exchange (ETDEWEB)
Passive films formed on mild steel in aqueous 8.6 mM NaCl solutions (pH 8), containing either MoO{sub 4}{sup 2-} or NO{sub 2}{sup -}, have been studied with X-ray photoelectron spectroscopy. For either anion these films are {approx}5 nm deep, and the primary chemical state of iron is Fe{sup 3+}. Following exposure to MoO{sub 4}{sup 2-}, the film consists of a sub-layer ({approx}4.1 nm) composed largely of ferric oxide/hydroxide, overlaid by Fe{sub 2}(MoO{sub 4}){sub 3} ({approx}0.6 nm). As regards NO{sub 2}{sup -}, spectra are consistent with the film being closely related to {gamma}-Fe{sub 2}O{sub 3}. Furthermore, a reduction product of NO{sub 2}{sup -}, potentially N{sub 2}, is present, displaying a depth profile comparable to that of molybdate.
2010-02-15
International Nuclear Information System (INIS)
A tri-functional polyhedral oligomeric silsesquioxane (POSS) based silane precursor R_xR_yR_z(SiO_3_/_2)_n (x + y + z = n = 6, 8, 10, ...) bearing 3-(N-(3-triethoxysilylpropyl)ureido)propyl, isooctyl and perfluoropropyl groups was synthesized and investigated as corrosion protective coating for AA 2024 alloy. Infrared reflection-absorption (IR RA) combined with X-ray photoelectron spectroscopy and atomic force microscopy provided information about partial self-assembling of coatings having a fluorine enriched upper layer with a low surface energy (#gamma#"t"o"t = 12.37 mN/m). The structural changes that accompanied corrosion produced under chronocoulometrical conditions were assessed from ex-situ IR RA spectra. A new band at 1690-1700 cm"-"1 appeared above the corrosion potential, and was assigned to the formation of amidonium ions and consequent relaxation of urea-urea associations.
2010-03-01
The pp{yields}K{sup +}{sigma}{sup +}n cross-section from missing-mass spectra
Energy Technology Data Exchange (ETDEWEB)
We utilize existing inclusive data on K{sup +}-meson momentum spectra of the reaction pp{yields}K{sup +}X at T{sub p}=2.3-2.85 GeV to deduce total cross-sections for pp{yields}K{sup +}{sigma}{sup +}n. The method used to extract those cross-sections is explained and discussed in detail. Our result for T{sub p}=2.85 GeV is consistent with the data point from a direct measurement at the same beam energy. The cross-section obtained for T{sub p}=2.3 GeV is with 13.7{+-}2.3 {mu}b considerably smaller than the value found in a recent experiment by the COSY-11 Collaboration at a somewhat lower beam energy, indicating that the pp{yields}K{sup +}{sigma}{sup +}n reaction cross-section could exhibit a rather unusual energy dependence. (orig.)
2007-05-15
Two-component mixtures of dorzolamide hydrochloride and timolol maleate were assayed by first derivative and ratio derivative spectrophotometric methods. The first method, derivative spectrophotometry, by the zero-crossing measurements, was used due to the drugs closely overlapping absorption spectra. Linear calibration graphs of first derivative values at 250.3 nm for dorzolamide hydrochloride and 315.8 nm for timolol maleate. The second method, is based on ratio first derivative spectrophotometry, the amplitudes in the first derivative of the ratio spectra at 242.9 and at 223.5 nm were selected to determine dorzolamide and timolol maleate in the binary mixture. Calibration graphs were established for 8.0-30.0 microg ml(-1) for dorzolamide hydrochloride and 3.0-24.6 microg ml(-1) for timolol maleate in binary mixture. Good linearity, precision and selectivity were found, and the proposed methods were applied successfully ...
2002-04-15
Precise characterisation of nanochannels in track etched membranes by SAXS and SANS
Energy Technology Data Exchange (ETDEWEB)
Poster session: Abstract is full text. Track membranes are thin polymer foils irradiated by heavy ions. The defects created by the heavy ions are located along the ions trajectory, the track. It is possible to open channels by etching with a chemical agent. These channels are very uniform. Small Angle Scattering (of X rays and neutrons) give global information about the characteristics of the channel shape. As the nanochannels are strictly parallel, an excellent sample orientation is required to obtain interpretable spectra. Then shoulders due to the oscillations of the Bessel function (radial part of the channel shape Fourier transform) are easily seen in the scattered intensity in the PXY data treatment software of SAS spectra allow to determine the channel diameter with its dispersion law, to demonstrate the existence of a wall thickness with a linearly varying density, and to assess the roughness. PXY can also detect non cylindric shapes ...
2003-05-01
International Nuclear Information System (INIS)
We present an approach for fabrication of intentionally positioned epitaxial InAs QDs in a micron sized light emitting diode. For site-selective growth, a combination of molecular beam epitaxy (MBE) and focused ion beam (FIB) implantation technology in an all-ultra-high-vacuum (UHV) setup has been employed. Single dot occupancy of almost 55 % on FIB patterned nano-depressions was successfully achieved. Thereafter, carrier injection and subsequent radiative recombination from the positioned InAs/GaAs self-assembled QDs was investigated by embedding these QDs in the intrinsic part of a GaAs-based micron sized p-i-n junction device. Few or single dot are expected to be electrically addressed in these devices. We report results from electroluminescence (EL) measurement which proves the single dot characteristics of our device. The EL spectra consist of sharp emission lines and their dependence on injection current shows linear behavior for exciton ...
2010-03-21
Early forecast of radiation-hazardous solar cosmic ray fluxes on the neutron monitors data
The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on several hours (2-10) an appropriate maximum of ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
We have investigated CeTSi{sub 3} and CeTGe{sub 3} (T = Rh and Ir) by measuring the magnetic susceptibility, specific heat, electrical resistivity, the resonant inverse photoemission (RIPES) and M{sub IV,V} x-ray absorption spectra (XAS). The germanides showed a very weak Kondo effect, but the silicides exhibited a negatively large Weiss temperature (approx. = -130 K) and a lnT dependence of magnetic resistivity above 100 K, suggesting that they are a Kondo-lattice compound with a high Kondo temperature T{sub K} (approx. = 100 K). The Curie-Weiss law suggests that Ce atoms in these compounds remain close to 3+ down to about 150 K in spite of their high T{sub K}. In general, both RIPES and M{sub IV,V} XAS support their apparently stable valency. (author)
1999-02-28
Can magnetospheric electron temperature be inferred from whistler dispersion measurements
International Nuclear Information System (INIS)
An approximate expression for whistler-mode group velocity is obtained, taking into account the effects of electron temperature and anisotropy, density and ion effects, effects of oblique propagation and a non-dipolarity of the dayside magnetospheric magnetic field. This expression is applied to the propagation of whistlers between one hemisphere and the other. It is pointed out that at frequencies close to the upper cut-off of whistler spectra, perturbations to whistler group delay times due to temperature effects can be of the same order of magnitude as, or even higher than, the corresponding perturbations due to finite electron density and ion effects. A method of magnetospheric electron temperature diagnostics is proposed and applied to two whistlers recorded at Halley (L = 4.3). It is pointed out that the values of temperature obtained from the analysis of whistler spectra depend on the choice of model of electron density and temperature ...
Anisotropy in Magnetic Properties and Electronic Structure of Single Crystal LiFePO4
Energy Technology Data Exchange (ETDEWEB)
We report the experimental and theoretical results on the anisotropies in the magnetic properties and x-ray absorption spectra of single-crystal LiFePO4. A mean-field theory is developed to explain the observed strong anisotropies in Lande g-factor, paramagnetic Curie temperature, and effective moment for LiFePO4 single crystals. The values of the in-plane nearest- and next-nearest-neighbor spin exchange (J1 and J2), interplane spin exchange (J{perpendicular}), and single-ion anisotropy (D), obtained recently from neutron scattering measurements, are used for calculating the Curie temperatures with the formulas derived from the mean-field Hamiltonian. It is found that the calculated Curie temperatures match well with that obtained by fitting the magnetic susceptibility curves to the modified Curie-Weiss law. For the polarized Fe K-edge x-ray absorption spectra of single-crystal LiFePO4, a different feature assignment for ...
2008-01-01
Advanced nuclear data for radiation-damage calculations
Energy Technology Data Exchange (ETDEWEB)
Accurate calculations of atomic displacement damage in materials exposed to neutrons require detailed spectra for primary recoil nuclei. Such data are not available from direct experimental measurements. Moreover, they cannot always be computed accurately starting from evaluated nuclear data libraries such as ENDF/B-V that were developed primarily for neutron transport applications, because these libraries lack detailed energy-and-angle distributions for outgoing charged particles. Fortunately, a new generation of nuclear model codes is now available that can be used to fill in the missing spectra. One example is the preequilibrium statistical-model code GNASH. For heating and damage applications, a supplementary code called RECOIL has been developed. RECOIL uses detailed reaction data from GNASH, together with angular distributions based on Kalbach-Mann systematics to compute the energy and angle distributions of recoil ...
1983-01-01
A comparison of two operational wave assimilation methods
A comparison is carried out between two operational wave forecasting/assimilation models for the North Sea, with the emphasis on the assimilation schemes. One model is the WAM model, in combination with an optimal interpolation method (OIP). The other model, DASWAM, consists of the third generation wave model PHIDIAS in combination with an approximate implementation of the adjoint method. In an experiment over the period February 19 - March 30, 1993, the models are driven by the same wind field (HIRLAM analysis winds), and the same observation data set is assimilated. This set consists of a) spectra from three pitch-and-roll buoys and b) Synthetic Aperture Radar (SAR) spectra from the ERS-1 satellite. Three analysis/forecast runs are performed: one without assimilation, one with assimilation of buoy measurements only, and one with all data assimilated. For validation, observations from four buoys, altimeter data from ERS-1 ...
1997-01-01
Energy Technology Data Exchange (ETDEWEB)
Temperature and concentration profiles of CO in a laminar, axisymmetric, premixed methane-air Bunsen flame are measured using line-of-sight diode laser absorption spectroscopy and computer tomographic (CT) reconstruction. Absorption spectra for P(20) (v=2<-1) and P(27) (v=1<-0) vibrotational transitions of CO were measured at 21 evenly spaced positions over a 1.33 cm span for a 1.3 cm radius flame. CT reconstruction algorithm was based on Fourier convolution. The tomographically reconstructed normalized transmission profiles derived from absorption spectra, in conjunction with a quantum mechanical model for vibrotational behavior of CO, yielded both temperature and concentration profiles. The Bunsen flame had 3 distinct zones: an inner rich-premixed flame zone, an outer non-premixed flame zone and an unburnt core region. The reconstructed temperature profile showed that the core region temperature ...
1993-12-01
International Nuclear Information System (INIS)
We report on the ultraviolet laser absorption spectroscopy of atomic Gd at 394-554 nm where two transition lines are place very closely by using a frequency-doubled beam of external-cavity diode laser (ECDL). One is from 999.121 to 26337.071 cm-1 and the other from 0 to 25337.755 cm-1. If two transition lines are placed closely within a continuous fine tuning range, the real-time measurement of the atomic excitation temperature is possible without any significant time consumption because at least two transition lines originating from different low-lying energy levels need to be investigated for the Boltzmann-plot. Since the spectral difference between the two transitions is only about 0.195 cm-1 (5.85 GHz), it is possible to record both the absorption spectra simultaneously as shown in Fig. 1. But the transition probabilities (or oscillator strengths) of these lines have not been measured accurately yet to the best of our ...
2003-11-07
Magnetic properties of laminated perovskite-like ferroelectromagnetics
International Nuclear Information System (INIS)
Magnetic properties of layer ferromagnets against the thickness are investigated. Two new compounds served for studies: Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1. The Moessbauer effect and the magnetic susceptibility measurements were applied in the experiment. The Faraday method was used in magnetic measurements in fields from 1 to 9,5 kOe. The results of Moessbauer measurements show that temperature dependence of the spectra is typical for compounds with superparamagnetic properties. The magnetic fields Hsub(n) on Fe"5"7 nuclei in Bisub(6)Tisub(2)Nbsub(0,5)Fesub(2,5)Osub(18) and Bi_7Ti_3Fe_3O_2_1 are similar and equal to 520+-10 kOe. Therefore it may be concluded that relaxation times of nuclear spins in these compounds are equal or close to each other. The lines of quadrupole splitting appear in spectra together at 20 K. The results of magnetic ...
1975-01-01
Principles of photon colliders
Energy Technology Data Exchange (ETDEWEB)
Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).
1995-02-01
Composite vector leptoquarks in e"+e-, #gamma#e, and #gamma##gamma# colliders
International Nuclear Information System (INIS)
We study the signals for composite vector leptoquarks in e"+e- colliders (CERN e"+e- collider LEP II, Next Linear Collider, and CERN Linear Collider) through their effects on the production of jet pairs, as well as their single and pair productions. We also analyze their production in #gamma#e and #gamma##gamma# collisions.
Spectroscopic characterization of alkane radical cations: Pt. 1
International Nuclear Information System (INIS)
Radical cations of various 3-methylalkanes (C_6-C_1_4) have been produced and stabilized by #gamma#-irradiation of the corresponding neutral compounds in saturated chlorofluorocarbon and perfluorocarbon matrices at 77 K. The perfluorocarbon matrices appeared more suitable for studies of the lighter radical cations, whereas the chlorofluorocarbon matrices were more suited for studies of the heavier radical cations; intermediary cations could be studied in both types of matrices. After irradiation, electronic absorptions associated with both the matrix and the alkane additive were observed. Pure spectra of the 3-methylalkane radical cations were obtained by difference spectrometry, after selective elimination of these cations by illumination. The electronic absorption spectra of the 3-methylalkane radical cations consist in all cases of a single broad absorption band. The spectral position of this band shifts to longer ...
1989-01-01
Energy Technology Data Exchange (ETDEWEB)
RangerMaster{trademark} is the embedded firmware for Quantrad Sensor`s integrated nuclear instrument package, the Ranger{trademark}. The Ranger{trademark}, which is both a gamma-ray and neutron detection system, was originally developed at Los Alamos National Laboratory for in situ surveys at the Plutonium Facility to confirm the presence of nuclear materials. The new RangerMaster{trademark} software expands the library of isotopes and simplifies the operation of the instrument by providing an easy mode suitable for untrained operators. The expanded library of the Ranger{trademark} now includes medical isotopes {sup 99}Tc, {sup 201}Tl, {sup 111}In, {sup 67}Ga, {sup 133}Xe, {sup 103}Pa, and {sup 131}I; industrial isotopes {sup 241}Am, {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 40}K, {sup 60}Co, {sup 232}Th, {sup 226}Ra, and {sup 207}Bi; and nuclear materials {sup 235}U, {sup 238}U, {sup 233}U, and {sup 239}Pu. To accomplish isotopic identification, a simulated ...
1998-12-31
Energy Technology Data Exchange (ETDEWEB)
The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22[sup o]C. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm[sup -1] (amide I), 1200-1300 cm[sup -1] (amide III) and 550-1030 cm[sup -1] (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm[sup -1] are tyrosines and cysteines. The radiation-induced changes in the secondary structure were ...
1993-03-01
International Nuclear Information System (INIS)
The purified integral membrane protein, band 3, from human erythrocytes was inserted into egg lecithin liposomes. The insertion of band 3 was determined from thermal transition data from the analysis of the C-H stretching region bands recorded at temperatures from 25 to -22"oC. Raman spectra show that band 3 considerably broadens and lowers the thermal transition of egg lecithin liposomes, suggesting the insertion of band 3. The band 3-inserted liposomes were irradiated with gamma-rays (40 Gy) and the radiation target groups were determined by the analysis of the structural sensitive Raman bands in the 1600-1700 cm"-"1 (amide I), 1200-1300 cm"-"1 (amide III) and 550-1030 cm"-"1 (side chain amino groups) regions. The radiation-sensitive groups as identified from Raman spectra in the region 550-1030 cm"-"1 are tyrosines and cysteines. The radiation-induced changes in the secondary structure were determined from amide I and ...
Energy Technology Data Exchange (ETDEWEB)
Changes in the phosphate metabolism of the transplanted SCCVII (squamous cell carcinoma VII) tumor were studied before and after irradiation using in vivo [sup 31]P-magnetic resonance spectroscopy (MRS). Phosphocreatine (PCr), [gamma]-, [alpha]-, [beta]-ATP, inorganic phosphate (Pi), phosphomonoester (PME), and phosphodiester (PDE) were detected in [sup 31]P-MR spectra of tumor tissues. The curve fitting method was employed for calculating each peak of [sup 31]P-MR spectra (PCr, [beta]-ATP, Pi, PME, PDE). The values of PCr, PCr/Pi, [beta]-ATP/Pi and pH decreased in proportion to the growth of tumor, whereas that of Pi, PME and PDE increased. But the changes of [beta]-ATP were minimal in degree. Based on the fact that the ratio of PCr/Pi highly correlated with tumor volume and showed the most remarkable change among various parameters, it might be the useful index for the tumor growth. Because the phospholipid metabolite PME ...
1992-03-01
Spatial distribution of IGC-30 Ge-detector's efficiency
International Nuclear Information System (INIS)
The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).
1993-12-02
Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR
International Nuclear Information System (INIS)
This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
The current status of rare B decays is reviewed based on recent observation of the penguin-diagram decay B {yields} K{sup *}{gamma} at CLEO. Rare B decays provide valuable information on the Standard Model parameters, and also could be a source of direct CP violation. It is emphasized that new physics beyond the Standard Model can appear in rare B decays, in some cases more drastically than in the CP Asymmetry of the B system. Inclusive measurement of the radiative transition b {yields} s{gamma} is promising. Hadronic penguin modes are very close to being observed at CLEO, and a discovery might be just around the corner. (author). 48 refs., 6 figs., 4 tabs.
1994-12-31
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to assess the feasibility of radiosterilization of drugs aqueous solutions and to evaluate the effects of some additives, such as mannitol, nicotinamide and pyridoxine, which might protect the drug from degradation. Metoclopramide was selected as a model drug. The structures of the degradation products were determined to gain insight on the radiolysis mechanisms in aqueous solution in order to design strategies to lower the drug degradation.Metoclopramide hydrochloride aqueous solutions with and without excipients were irradiated either with gamma rays or high-energy electrons. HPLC-DAD was used to measure the loss of chemical potency and to quantify the degradation products which were also characterized by LC-APCI-MS-MS. Metoclopramide recovery for gamma and elec...
2008-01-01
PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.
Energy Technology Data Exchange (ETDEWEB)
We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...
2006-10-29
Indirect Dark Matter Signals from EGRET and PAMELA compared
Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. The excess of diffuse Galactic Gamma Rays from EGRET shows all the features expected from DMA. The new precise measurements of the antiproton and positron fractions from PAMELA are compared with the EGRET excess. It is shown that the charged particles are strongly dependent on the propagation model used. The usual propagation models with isotropic propagation models are incompatible with the recently observed convection in our Galaxy. Convection leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in the halo to outer space. It is shown that such anisotropic propagation models including convection prefer a contribution from DMA for the ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.
1988-01-01
Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report
Energy Technology Data Exchange (ETDEWEB)
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
2003-04-08
International Nuclear Information System (INIS)
Irradiation processing of food in the prepackaged form may affect chemical and physical properties of the plastic packaging materials. The effect of #gamma#-irradiation doses (2.5-10.0 kGy) on polypropylene (PP)-based retortable food packaging materials, were investigated using Fourier transform infrared (FTIR) spectroscopic analysis, which revealed the changes happening to these materials after irradiation. The mechanical properties decreased with irradiation while oxygen transmission rate (OTR) was not affected significantly. Colour measurement indicated that Nylon 6 containing multilayer films became yellowish after irradiation. Thermal characterization revealed the changes in percentage crystallinity.
2007-07-01
Dislocation pinning in electron-irradiated copper as a function of electron energy and irradiation
Dislocation priming measurements were performed in the kHz range in ASARCO copper. The samples and irradiation facilities are constructed so as to allow successive irradiation of samples both with electrons and gamma rays. The gamma rays were produced by stopping 2.8-MeV electrons in a gold target. The change of the type of irradiation could be achieved without any handling of the sample. Thus it is possible to detect rather small differences between the two types of irradiation. Recovery experiments at 400 deg K after 75 deg K irradiation and pinning rates during irradiation at 400 deg K and 75 deg K were made. (GE)
1973-01-01
Energy Technology Data Exchange (ETDEWEB)
The effective fraction of delayed photoneutrons ({beta}{sup ph}) has been theoretically defined and experimentally determined in various different configurations of the LWR-PROTEUS critical facility. The peculiarity lies in the fact that the reactor has D{sub 2}O in only one of the four fuelled zones, thus D({gamma},n)H reactions take place mainly in this region. The work is divided into three parts. The first part is devoted to the description of the LWR-PROTEUS facility and to the measurements of {beta}{sup ph}. These experimental values are derived from standard inverse-kinetics analysis of neutron flux decay experiments for each of seven different configurations, with nine additional groups of neutron precursors to account for photoneutron effects. In the second part, the coupled neutron and gamma Boltzmann equations are reduced to exact point kinetics equations using the photon infinite-velocity approximation, and then ...
2003-11-01
Experience and recent developments in nuclear forensics at the Institute of Isotopes
International Nuclear Information System (INIS)
Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental ...
Accelerator aspects of #gamma#-#gamma# colliders
International Nuclear Information System (INIS)
There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.
2000-11-21
Excited leptons and quarks at. gamma. gamma. /. gamma. e colliders
Energy Technology Data Exchange (ETDEWEB)
We discuss the search of excited leptons and quarks with spin 1/2 at {gamma}{gamma} and at {gamma}e colliders. We show that {gamma}{gamma} colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l{sup *}l{gamma} transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).
1992-02-06
Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.
2010-01-01
International Nuclear Information System (INIS)
The nuclear structure of A #propor to# 100 nuclei has been studied in the frame of this thesis with a recently developed #beta# - #gamma# - #gamma# triple coincidence fast timing technique and different models such as shell model, hydrodynamic model, Nilsson and particle-rotor models. This technique which allows the measurement of the level lifetimes in the ps range has been applied at JOSEF at the research reactor DIDO of KFA Juelich in studes of the short-lived neutron-rich nuclei in the A #approx =# 100 region. Lifetimes of level in "9"6,"9"8,"1"0"0 ZR, "9"9,"1"0"1-"1"0"4 Nb, "1"0"0-"1"0"5 Mo have been measured, which are in many cases completely new, and otherwise more precise than previously published data. From the lifetimes of the members of rotational bands, the size of the nuclear deformations has been deduced. (orig./HSI).
Measurement of "1"0"1Tc Half-Life
International Nuclear Information System (INIS)
75 mg (NH_4)_6Mo_7O_24 #centre dot# 4H_2O solution was irradiated for 20 min in miniature neutron source reactor (MNSR) and cooled for 12 min. In the conditions of 0.8 mol/L HNO_3, phase ratio 1:1, the solution of "1"0"1Tc sample was extracted twice with #alpha#-benzoin oxime/ethyl acetate phase to remove "1"0"1Mo and a radiochemically pure and carrier-free "1"0"1Tc product was obtained. The half-life of "1"0"1Tc was accurately measured with a HPGe #gamma#-detector by following 306.8 keV #gamma#-ray about 150 min, and processed the data by three methods, R-value method, iterative method and translation method. Five parallel measurments gave a half-life (14.02 #+-# 0.01) min (n=5) for "1"0"1Tc. (authors)
2009-11-01
Using Zgamma candidate events collected by the CDF detector at the Tevatron Collider, we search for potential anomalous (non-standard-model) couplings between the Z boson and the photon. At the hard scatter energies typical of the Tevatron, standard model Zgamma couplings are too weak to be detected by current experiments; hence any evidence of couplings indicates new physics. Measurements are performed using data corresponding to an integrated luminosity of 4.9 /fb in the Z -> nunubar decay channel and 5.1 /fb in the Z -> l^+l^- (l=mu, e) decay channels. The combination of these measurements provides the most stringent limits to date on Zgamma trilinear gauge couplings. Using an energy scale of Lambda = 1.5 TeV to allow for a direct comparison with previous measurements, we find limits on the CP-conserving parameters that describe Zgamma couplings to be |h_3^{\\gamma,Z}| < 0.017 and ...
2011-01-01
Heat capacities between 1.5 and 16 K and superconductivity of V/H and Nb/H alloys
International Nuclear Information System (INIS)
Molar heat capacities have been measured for VHsub(n) and NbHsub(n) with n up to 1.93 at temperatures between 1.5 and 16 K. The height of the peak in plots of the electronic specific heat, indicating superconductivity, diminishes with increasing hydrogen content in the #alpha# + #beta# two-phase region, and can be taken as a measure of the fractional amount of #alpha#-phase present (lever-rule). In NbHsub(n) accordingly, the two-phase region presumably extends up to n = approximately 0.9 at helium temperatures. No hydride phase, including VH_2 and NbH_2, showed superconductivity above 1.5 K. The measured #gamma#-coefficients of the V/H-alloys agree with APW band-structure calculations for V metal in the range 5 =< nsub(e) =< 7 of band electron concentration. They coincide with the #gamma#-coefficients of V/Cr-alloys reported in the literature. Hence VHsub(n) represents another ...
1977-05-01
International Nuclear Information System (INIS)
CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint ...
2009-06-07
Compressed-shell integrity measurements in spherical implosion experiments
International Nuclear Information System (INIS)
The shell integrity near peak compression of spherical implosions using the 60-beam, 30-kJ UV OMEGA laser system [Opt. Commun. 133, 495 (1997)] has been measured. Hot core emission backlights a shell with a thin titanium-doped layer that is imaged at x-ray photon energies above and below the titanium K edge. The x-ray intensity ratio between the two images is related to perturbations in the cold, or absorbing, part of the shell. The measured cold-shell areal-density modulations, integrated over the time of peak compression, are of the order of 25% to 50% with nonuniformity spectra peaked at spatial wavelengths of 30 to 50 #mu#m and with the smallest detectable nonuniformity features extending down to spatial wavelengths of 12 to 15 #mu#m. Hot-shell areal-density modulations of the emitting part of the shell (inner edge) are of the order of 13% to 20%. The measured shell modulations are in agreement with ...
2001-06-01
Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices
International Nuclear Information System (INIS)
Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some ...
2005-10-23
Energy Technology Data Exchange (ETDEWEB)
With an objective to detect gas leaking from an underground gas pipeline, discussions have been given on a method which utilizes acoustic characteristics of leakage. On leaking sound generated from damaged portions, the form of damaging was hypothesized as pinholes, and spectra of leaking sounds from holes with different diameters were measured. The dominant frequency decreases as the hole diameter increases, while it is in a region of relatively high frequency of 1 kHz or higher. However, detection from the ground surface was impossible when cover soil has thickness from 0.5 to 1.5 m. In an experiment to measure leaking sound inside the pipe, pressure in the pipe was adjusted to 0.02 atm which is a standard pressure for a low-pressure pipe, and the sound was measured when the hole diameters were varied. In any of the results obtained by varying the hole diameter, spectra having the ...
1997-05-27
Energy Technology Data Exchange (ETDEWEB)
We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.
1997-10-01
International Nuclear Information System (INIS)
We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.
1988-09-18
Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation
International Nuclear Information System (INIS)
In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light ...
1992-10-25
Measurement of $\\phi$(1020) meson leptonic width with CMD-2 detector at VEPP-2M Collider
The $\\phi$(1020) meson leptonic width has been determined from the combined analysis of 4 major decay modes of the resonance ($\\phi\\to K^+ K^-,K^0_LK^0_S,\\pi^+\\pi^-\\pi^0,\\eta\\gamma$) studied with the CMD-2 detector at the VEPP-2M $e^+e^-$ collider. The following value has been obtained: $\\Gamma(\\phi\\to e^+e^-) = 1.235\\pm 0.006\\pm 0.022$ keV. The $\\phi(1020)$ meson parameters in four main decay channels have been also recalculated: $B(\\phi\\to K^+K^-) = 0.493\\pm 0.003\\pm 0.007$, $B(\\phi\\to K_LK_S) = 0.336\\pm 0.002\\pm 0.006$, $B(\\phi\\to\\pi^+\\pi^-\\pi^0) = 0.155\\pm 0.002\\pm 0.005$, $B(\\phi\\to\\eta\\gamma) = 0.0138\\pm 0.0002\\pm 0.0002$.
2010-01-01
Investigation of natural radionuclides in selected NORM-samples
International Nuclear Information System (INIS)
A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different densities, and the analysis ...
2005-09-20
Energy Technology Data Exchange (ETDEWEB)
The effect of the nitrogen uptake in {alpha}-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic {alpha}-Fe phase (50%). The 20% of specimen volume form {alpha}'-Fe and {alpha}''-Fe{sub 16}N{sub 2} phases. The last 30% occupy the {gamma}'-Fe{sub 4}N, ferro- and paramagnetic {epsilon} phases, and {gamma}-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into {alpha}-iron particles which results in the formation of paramagnetic {epsilon}({zeta})-Fe{sub 2}N phase. This phase ...
2001-09-01
International Nuclear Information System (INIS)
The effect of the nitrogen uptake in #alpha#-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic #alpha#-Fe phase (50%). The 20% of specimen volume form #alpha#'-Fe and #alpha#''-Fe_1_6N_2 phases. The last 30% occupy the #gamma#'-Fe_4N, ferro- and paramagnetic #epsilon# phases, and #gamma#-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into #alpha#-iron particles which results in the formation of paramagnetic #epsilon#(#zeta#)-Fe_2N phase. This phase also dominates the surface of #alpha#-iron specimen ...
2001-09-01
Energy Technology Data Exchange (ETDEWEB)
We present a systematic analysis of backward pion photoproduction for the reactions {gamma}p{yields}{pi}{sup 0}p and {gamma}p{yields}{pi}{sup +}n. Regge phenomenology is applied at invariant collision energies above 3GeV in order to fix the reaction amplitude. A comparision with older data on {pi}{sup 0}- and {pi}{sup +}-photoproduction at {theta}=180 indicates that the high-energy limit as given by the Regge calculation could be reached possibly at energies of around {radical}(s){approx_equal}3 GeV. In the energy region of {radical}(s){<=}2.5 GeV, covered by the new measurements of {gamma}p{yields}{pi}{sup 0} p differential cross-sections at large angles at ELSA, JLab, and LEPS, we see no clear signal for a convergence towards the Regge results. The baryon trajectories obtained in our analysis are in good agreement with those given by the spectrum of excited baryons. (orig.)
2009-04-15
K-matix theory in relation to MQDT and applications to atomic spectra
Energy Technology Data Exchange (ETDEWEB)
A summary of the basic principles of K-matrix theory and examples of its applications to atomic spectra are discussed. (AIP)
1990-04-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.