WorldWideScience
1

IMEF gamma scanning system  

International Nuclear Information System (INIS)

The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

1989-09-10

2

Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning  

International Nuclear Information System (INIS)

The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).

3

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also ...

4

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also ...

2007-03-15

5

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the ...

2009-03-01

6

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the ...

2007-06-15

7

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the ...

2001-05-01

8

Interpretation of gamma-scanning data from the ORR demonstration elements  

Energy Technology Data Exchange (ETDEWEB)

The HEU and LEU fuel elements used in the ORR whole-core demonstration were gamma-scanned to determine the axial distribution of the {sup 140}La and {sup 137}Cs activities. Analysis of this data is now complete. From the {sup 140}La activity distributions cycle-averaged powers were determined while the {sup 137}Cs data provided a measure of the final {sup 235}U burnup in the fuel elements. A method for calculating correction factors for activity gradients transverse to the fuel element axis is presented and is applied to the first mixed core used in the demonstration during the gradual transition to an all LEU core. Results based on the gamma-scanning of the LEU fuel followers are also presented. Improved burnup calculations against which the experimental results are to be compared are now in progress. 7 refs., 21 figs., 3 tabs.

1989-01-01

9

A Simulation Study on a Radioactive Nuclide's Distribution within a Fuel rod by a Tomographic Gamma Scanning  

Energy Technology Data Exchange (ETDEWEB)

Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising ...

2006-07-01

10

Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system  

Energy Technology Data Exchange (ETDEWEB)

The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide ...

2003-05-01

11

Power density distribution by gamma scanning of fuel rods measurement technique in RA-8 critical facility  

International Nuclear Information System (INIS)

Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)

1999-10-26

12

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, ...

2007-07-01

13

Versatile gamma scanning system  

International Nuclear Information System (INIS)

(Feb 1972). United States Swinth, KL Weber, JW San Francisco, Calif.

14

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center ...

2007-03-15

15

Burnup determination of spent nuclear fuel in the pool  

Energy Technology Data Exchange (ETDEWEB)

A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device ...

1998-06-01

16

Fuel element powers, STVU masses, and burnups from gamma-scanning data: Preliminary analysis of irradiated ORR (Oak Ridge Research Reactor) LEU fuel elements  

Energy Technology Data Exchange (ETDEWEB)

Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.

1988-01-01

17

The measurement of the fission product ratios, {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuel by gamma scanning method  

Energy Technology Data Exchange (ETDEWEB)

We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.

1997-10-01

18

The measurement of the fission product ratios, "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuel by gamma scanning method  

International Nuclear Information System (INIS)

We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.

1988-09-18

19

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of ...

2007-09-21

20

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. ...

2003-10-01

21

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

International Nuclear Information System (INIS)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show ...

2003-10-01

23

Gamma scanning of FBTR fuel pins  

International Nuclear Information System (INIS)

This paper presents the results obtained in the gamma scanning of two fuel pins from the bent subassembly of the fast breeder test reactor (FBTR) using a segmented gamma scanning system employing segment correlation developed for the assay of glove box solid waste. In addition to the actinide profiles, the paper also discusses the fission products and clad activation product profiles and tries to correlate the experimental values of the latter with computed values. (author). 4 refs., 1 fig., 1 tab.

24

Inventory determination of low and intermediate level radioactive waste of Paks Nuclear Power Plant origin  

International Nuclear Information System (INIS)

In the execution of disposal of low and intermediate level radioactive wastes, it is important to evaluate accurately the kind and quantity of each radionuclide in the wastes. For such an evaluation, correlation of non-gamma-emitting nuclides based on gamma-emitting nuclides is recommended and regarded as a partial method. This method necessitates a completion of a highly accurate and reliable nondestructive assay system of gamma-emitting nuclides for partical use. In 1992, in support of the new waste disposal program in Hungary, Paks NPP initiated a waste characterization program to determine the radiological properties of its rad wastes. A segmented gamma scanning system has been set up to measure the gamma-emitting nuclides in 2000 litre low level drums following in-drum compaction. In the framework of the program a radiochemical analysis ...

25

Modification of SGS system for application to various sized drums  

Energy Technology Data Exchange (ETDEWEB)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it ...

2005-11-15

26

Modification of SGS system for application to various sized drums  

International Nuclear Information System (INIS)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy ...

2005-11-01

27

Remote temperature inversion sensor  

International Nuclear Information System (INIS)

In conducting aircraft surveys for uranium, it is found that temperature inversions can give spurious results because they promote accumulation of radon gas in the atmosphere. The "2"1"4Bi (daughter product of radon) gamma-rays detected from the atmosphere-borne radon are difficult to separate from the "2"1"4Bi gamma-rays originating from the ground, and providing a signature for uranium deposits. The purpose of the present study was to examine the feasibility of making remote temperature soundings of the atmosphere below a low-flying aircraft (140 m or less above ground) by the inversion of radiance measurements taken in the 15-micron carbon dioxide absorption band. Such measurements would identify those temperature inversion conditions possibly leading to an unacceptably large background of gamma-rays from the atmospheric radon. Thus, the incidence of spurious aerial survey data ...

1977-01-01

28

Laser monitoring of the size and polarization of the gamma beams of #gamma##gamma# and e#gamma# colliders  

International Nuclear Information System (INIS)

It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).

29

A detailed analysis of the properties of radiolyzed proteinaceous amino acids  

International Nuclear Information System (INIS)

The thermal behaviour of 21 proteinaceous l-amino acids either as pristine samples and also as radiolyzed (3.2 MGy) samples was studied with the differential scanning calorimeter. The onset and peak melting point as well as the melting enthalpy of all samples before and after the radiation treatment was measured and reported. The residual amount of each amino acid survived to the radiation dose of 3.2 MGy (N_#gamma#) was measured from the melting enthalpies before and after radiolysis and hence the radiation resistance of each amino acid has been determined. The radiolysis causes a systematic reduction of the melting enthalpy and a shift of the onset and peak melting point to lower values. It is shown that N_#gamma# does not correlate with the melting points of the amino acids but shows a correlation with the entity of the shift of the melting point peaks occurred after radiolysis. ...

2011-03-01

30

Computer analysis and control for nondestructive gamma scanning of LMFBR fuel pins  

International Nuclear Information System (INIS)

A program to modernize existing computer control and data analysis in a precision gamma-scanning system is described. This involves interfacing a new computer-based multichannel analyzer to existing equipment through a CAMAC system with an intelligent crate controller and writing software for scan control and data reduction. Both hardware and software requirements are discussed. 6 figures.

31

Measuring the beam polarizations and the luminosity at photon-photon colliders  

Energy Technology Data Exchange (ETDEWEB)

We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)

1993-11-01

33

Reconstruction of the activity of point sources for the accurate characterization of nuclear waste drums by segmented gamma scanning  

International Nuclear Information System (INIS)

This work improves the reliability and accuracy in the reconstruction of the total isotope activity content in heterogeneous nuclear waste drums containing point sources. The method is based on #chi#"2-fits of the angular dependent count rate distribution measured during a drum rotation in segmented gamma scanning. A new description of the analytical calculation of the angular count rate distribution is introduced based on a more precise model of the collimated detector. The new description is validated and compared to the old description using MCNP5 simulations of angular dependent count rate distributions of Co-60 and Cs-137 point sources. It is shown that the new model describes the angular dependent count rate distribution significantly more accurate compared to the old model. Hence, the reconstruction of the activity is more accurate and the errors are considerably reduced that lead to more reliable results. ...

2011-06-01

35

Study on the angular. gamma gamma. -correlations for nuclei of Sr even-even isotopes  

Energy Technology Data Exchange (ETDEWEB)

The angular ..gamma gamma..-correlations for nuclei of Sr even-even isotopes with A=82, 84, 86, 88 were measured. Multipole structurs of ..gamma..-transtion series and th coefficients multipole mixing were determined.

1984-05-01

36

Study on the angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes  

International Nuclear Information System (INIS)

The angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes with a=8 82, 84, 86, 88 were measured. Multipole structurs of #gamma#-transtion series and th coefficients multipole mixing were determined.

1983-04-01

37

Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences  

Science.gov (United States)

The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)

1973-08-01

38

Assay of the uranium and plutonium content in process residues and wastes using the correction for sample self attenuation in segmented gamma scanning system  

International Nuclear Information System (INIS)

A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurement results is also studied. The measurement results of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The uncertainty of measurement results for uranium and plutonium ...

1998-09-01

39

Application od scaling technique for estimation of radionuclide inventory in radioactive waste  

International Nuclear Information System (INIS)

Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and TRUs. The measurements ...

1996-09-16

40

#gamma##gamma# Cross-sections and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We summarize the predictions of different models for total #gamma##gamma# cross-sections. The experimentally observed rise of #sigma#_#gamma#_#gamma# with s radical _#gamma#_#gamma#, faster than that for #sigma#_p_-_b_a_r_p, #sigma#_#gamma#_p is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of #sigma#_#gamma#_#gamma# with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range 300< s radical_#gamma#_#gamma# <500 GeV. We further show that the difference in ...

2001-10-11

41

Semihard production of tensor mesons in #gamma##gamma#-collisions and the perturbative Odderon  

International Nuclear Information System (INIS)

The cross sections of neutral tensor mesons T=a_2, f, f', ... production in the exclusive #gamma##gamma##->#TT' or semiexclusive #gamma##gamma##->#TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV"2 are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future #gamma##gamma#-colliders is discussed too. (orig.).

42

Radwaste Drum Assay Technology by Segmented Gamma Scanning System  

Energy Technology Data Exchange (ETDEWEB)

Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated from nuclear power plants and other nuclear facilities prior to deliver to a disposal sites. Individual history records of the radioactive waste should be described the information about the activity of nuclides in the drum, total activity, weight, the type of waste. So a fully automated nuclide analysis assay system(non-destructive) of a radwaste drum was developed. For the nuclides that could not be analysed directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then the scaling factors were used to calculate the activities of {alpha} - and {beta}-emitters. This assay system divided a drum into 8 segments, a segment into 8 sectors to minimize analysis error, and used several methods(transmission ratio, differential peak absorption, mean density ...

2009-01-15

43

Hanaro fuel gamma scanning  

Energy Technology Data Exchange (ETDEWEB)

One bundle of Hanaro fuel irradiated up to 50%-burnup and cooled for 6 months was transported to IMEF for PIE, which has 6 elements. At first we measured the longitudinal distribution and the rotational distribution of several dominant peaks intensities from the bundle. After dismantling of the bundle we measured the longitudinal distribution of {sup 137}Cs and {sup 134}Cs peaks in each fuel element to see the burn-up feature. And finally we found out the relative number distribution of {sup 137}Cs and {sup 134}Cs for each detection point, which would be used for burn-up calculation. The relative detection efficiency of the scanning system was obtained experimentally by using the {sup 134}Cs peaks. We also checked up the azimuthal difference of peak intensity for each element, which are resulted about 2% of difference. These data will be used for the further analysis of Hanaro fuel performance evaluation. (author)

1999-09-01

44

Inguino-scrotal hernia detection in the early phase of a bone scan  

International Nuclear Information System (INIS)

A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd

1999-11-01

45

Transuranic separation using organophophorus extractants adsorbed onto superparamagnetic carriers.  

Energy Technology Data Exchange (ETDEWEB)

Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the ...

1998-10-07

46

CANDU 6 fuel behaviour in power ramp conditions  

International Nuclear Information System (INIS)

The facilities in the Institute for Nuclear Research at Pitesti allow the testing, handling and examination of nuclear fuel and irradiated materials. The most important facilities are the TRIGA Steady State Research and Material Test Reactor and the Post-Irradiation Examination Laboratory (PIEL). The purpose of this work is to determine by post-irradiation examination, the behavior of CANDU fuel, irradiated in 14 MW TRIGA reactor. The fuel was irradiated in power ramp conditions. The results of post-irradiation examination are: - Visual inspection and photography of the outer appearance of sheath; - Profilometry (diameter, bending, ovality) and length measuring; - Determination of axial and radial distribution of the fusion products activity by gamma scanning and tomography; - Microstructural characterization by metallographic and ceramographic analyzes; - Mechanical properties determination. The data obtained from the ...

2009-10-12

47

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear ...

2007-08-21

48

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear ...

2007-08-21

49

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for ...

50

Gamma-gamma collider based on Compton back-scattering  

International Nuclear Information System (INIS)

A #gamma##gamma# collider would extend and complement the physics capability of a linear collider; e.g. it would be suitable for direct measurement of the partial decay width of a Higgs boson into two gamma quanta. This paper discusses choice of laser parameters, luminosity optimization, electron and laser parameters for a gamma- gamma collider as a second interaction region for the Next Linear Collider, laser path, and the lasers. It is concluded that a gamma- gamma collider is technically feasible; however it will require a significant investment in preparatory R ampersand D.

1996-08-25

51

Measurements of the CKM angle $\\gamma/\\phi_{3}$ at B-factories  

CERN Document Server

The CKM angle $\\gamma/\\phi_{3}$ had been measured by two B-factories, the PEPII collider for the BaBar experiment and the KEKB collider for the Belle experiments. The present paper reports recent progress in $\\gamma/\\phi_{3}$.

2011-01-01

52

Studying the triple-Higgs vertex in the process. gamma. gamma. yields HH at TeV energies  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process {gamma}{gamma}{yields}HH are calculated. It is shown that the cross section is measurable at TeV {gamma}{gamma} colliders and is marginally sensitive to the triple-Higgs variation. (orig.).

1992-06-04

53

Studying the triple-Higgs vertex in the process #gamma##gamma##->#HH at TeV energies  

International Nuclear Information System (INIS)

In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process #gamma##gamma##->#HH are calculated. It is shown that the cross section is measurable at TeV #gamma##gamma# colliders and is marginally sensitive to the triple-Higgs variation. (orig.).

54

Semihard production of tensor mesons in. gamma. gamma. -collisions and the perturbative Odderon  

Energy Technology Data Exchange (ETDEWEB)

The cross sections of neutral tensor mesons T=a{sub 2}, f, f', ... production in the exclusive {gamma}{gamma}{yields}TT' or semiexclusive {gamma}{gamma}{yields}TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV{sup 2} are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future {gamma}{gamma}-colliders is discussed too. (orig.).

1992-03-01

55

Performance of a modified two-dimensional gamma scan system in spent fuel pin studies  

International Nuclear Information System (INIS)

This work assesses the performance of a modified two-dimensional gamma scan system in spent fuel pin studies. The techniques for a two-dimensional gamma scan studied have been developed at the Hot Cell of Institute of Nuclear Energy Research (INER). Samples are acquired from the spent fuel pin, TPC-SP-C1, which was irradiated in a commercial reactor core (the first of its kind in Taiwan) for 2 years and then deposited in a cooling pool for 10 years. The spent fuel pin was then transferred into INER for further examination. The gamma scanning system was driven by a step motor which had an accuracy within 0.1 mm in both X-Y directions. Data obtained from this system are presented in both an isotopic distribution and contour plot. Results in this study closely correspond to those in other investigations, thereby confirming the effectiveness of this modified system. ...

1999-11-01

56

On the decay of "2"0"3Bi  

International Nuclear Information System (INIS)

The radioactive decay of "2"0"3Bi is studied. A level scheme is proposed for "2"0"3Pb on the basis of #gamma#-ray and electron spectra and #gamma#-#gamma# coincidence measurements. The experimental data are compared with theoretical results obtained in a three quasiparticle approximation. (Auth.).

57

RF plasma nitriding of severely deformed iron-based alloys  

International Nuclear Information System (INIS)

The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10"-"5 bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of #epsilon# and #gamma#' nitrides in the compound layer, with a preferential formation of #gamma#' at the expense of the ...

2003-05-15

58

SUSY at e{gamma}/{gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the sparticle production processes e{gamma} {yields} e tilde(Z tilde){sub 1} and {gamma}{gamma} {yields} (f tilde)(f tilde and bar) at high energy e{gamma} and {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e{gamma} colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e{gamma} {yields} (e tilde)(Z tilde){sub 1}. We show that the standard background processes e{gamma} {yields} {nu}W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes ...

1994-04-01

59

SUSY at e#gamma#/#gamma##gamma# colliders  

International Nuclear Information System (INIS)

We investigate the sparticle production processes e#gamma# #-># e tilde(Z tilde)_1 and #gamma##gamma# #-># (f tilde)(f tilde and bar) at high energy e#gamma# and #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e#gamma# colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e#gamma# #-># (e tilde)(Z tilde)_1. We show that the standard background processes e#gamma# #-># #nu#W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e#gamma# #-># (e ...

1994-04-01

60

{gamma}{gamma} Cross-sections and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We summarize the predictions of different models for total {gamma}{gamma} cross-sections. The experimentally observed rise of {sigma}{sub {gamma}}{sub {gamma}} with s radical {sub {gamma}}{sub {gamma}}, faster than that for {sigma}{sub p-barp}, {sigma}{sub {gamma}}{sub p} is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of {sigma}{sub {gamma}}{sub {gamma}} with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for ...

2001-10-11

61

Development and application of a gamma scanning system for LLW and MLW packages  

International Nuclear Information System (INIS)

The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.

1993-09-05

62

Measurement of the branching fractions for $J/\\psi\\to\\gamma\\pi^0$, $\\gamma\\eta$ and $\\gamma\\eta^{\\prime}$  

CERN Document Server

The decay modes $\\jpsi\\ar\\gamma\\pi^0, \\gamma\\eta$ and $\\gamma\\etap$ are analyzed using a data sample of 58 million $\\jpsi$ decays collected with the BESII detector at BEPC. The branching fractions are determined to be: $Br(\\jpsi\\ar\\gamma\\pi^0)=(3.13^{+0.65}_{-0.44})\\times10^{-5}$, $Br(\\jpsi\\ar\\gamma\\eta)=(11.23\\pm0.89)\\times10^{-4}$, and $Br(\\jpsi\\ar\\gamma\\etap)=(5.55\\pm0.44)\\times10^{-3}$, where the errors are combined statistical and systematic errors. The ratio of partial widths $\\Gamma(\\jpsi\\ar\\gamma\\etap)/\\Gamma(\\jpsi\\ar\\gamma\\eta)$ is measured to be $4.94\\pm0.40$, and the singlet-octet pseudoscalar mixing angle of $\\eta-\\etap$ system is determined to be $\\theta_{P}=(-22.08\\pm0.81)^{\\circ}$.

2006-01-01

63

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

64

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

65

Development and application of gamma scanning technology for on-line investigation of industrial process columns and vessels  

International Nuclear Information System (INIS)

Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (author)

1998-10-30

66

A novel gamma scanning system for on-line diagnostic inspection of industrial process columns  

International Nuclear Information System (INIS)

A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)

67

High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry  

CERN Document Server

In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers ...

2004-01-01

69

Irradiation characteristics examination technology development of irradiated nuclear material and high burn-up fuels  

Energy Technology Data Exchange (ETDEWEB)

The research and development for the first year of the project are performed through specialization of researchers, information from aborad and international cooperation, securement of advanced nuclear technology, development and installation of test equipment, application of external man-power, establishment of advanced test techniques, and certified test method. 1. Absolute efficiency measurement examination technology development of gamma scanning system 2. Sample preparation technology development of SEM and EPMA for micro-structural observation and chemical composition analysis 3. Irradiated high burn-up nuclear fuel transportation and test for PWR 4. Development of hot cell examination techniques and equipment 5. Acquirement of KOLAS system. In addition to the project, the following activities are carried out as follows; - PIE of Hanaro fuel(KH99H-001) - PIE of U-Mo advanced nuclear fuel irradiated at Hanaro - PIE of ...

2002-12-01

70

Measurement of #gamma#-ray emission probabilities for "1"0"1Mo  

International Nuclear Information System (INIS)

"1"0"1Mo is one of the key nuclides in diagnosing fission burn-up. However, it's difficult to measure its nuclear decay data due to its short half-life. Present study concerns in the measurements of #gamma#-ray emission probabilities, P_#gamma#, of "1"0"1Mo and "1"0"1Tc using the balance of scheme method and the entire process recording. The P_#gamma# of "1"0"1Mo by the entire process recording is about 5% lower than that by using the balance of scheme method. The P_#gamma# of "1"0"1Tc using the two methods agree each other very well. So, it seems the #gamma#-ray emission probabilities as well as measurement method still need study further for "1"0"1Mo. (authors)

2006-07-01

71

Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring  

International Nuclear Information System (INIS)

A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.

72

Semihard production of neutral pseudoscalar and tensor mesons in photon-photon collisions  

Energy Technology Data Exchange (ETDEWEB)

We investigate the semihard production of neutral pseudoscalar and tensor mesons in high-energy [gamma][gamma] collisions (M=P=[pi][sup 0], [eta], [eta]' or M=T=a[sub 2], f[sub 2], f[sub 2]'). We deal with the exclusive [gamma][gamma][yields]MM' or semi-exclusive [gamma][gamma][yields]MX reactions (X is the hadron jet with not too large mass). The considered transfer momenta are small in comparison with the photon energies and they are large in comparison with the confinement scale. The amplitudes of these processes are determined by the odderon exchange, i.e. three-gluon exchange in the lowest order of perturbative QCD. The cross sections are calculated in this approximation. The possibility of measurements at LEP and at future [gamma][gamma] colliders is discussed. (orig.).

1992-12-21

73

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

74

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

75

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

76

\\psi(2S) Decays into $\\J$ plus Two Photons  

CERN Document Server

Using $\\gamma \\gamma J/\\psi, J/\\psi \\ra e^+ e^-$ and $\\mu^+ \\mu^-$ events from a sample of $14.0\\times 10^6$ $\\psip$ decays collected with the BESII detector, the branching fractions for $\\psip\\ra \\pi^0\\J$, $\\eta\\J$, and $\\psi(2S)\\ar\\gamma\\chi_{c1},\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi$ are measured to be $B(\\psip\\ra \\pi^0\\J) = (1.43\\pm0.14\\pm0.13)\\times 10^{-3}$, $B(\\psip\\ra \\eta\\J) = (2.98\\pm0.09\\pm0.23)%$, $B(\\psi(2S)\\ar\\gamma\\chi_{c1}\\ar\\gamma\\gamma\\jpsi) = (2.81\\pm0.05\\pm 0.23)%$, and $B(\\psi(2S)\\ar\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi) = (1.62\\pm0.04\\pm 0.12)%$.

2004-01-01

77

A measurement of the parity-violating gamma-ray asymmetry in the neutron-proton capture  

Energy Technology Data Exchange (ETDEWEB)

The {rvec n} + p {yields} d + {gamma} experiment under construction at LANSCE studies the weak interaction between neutrons and protons. The experiments will measure the directional dependence of the parity-violating {gamma}-ray asymmetry, A{sub {gamma}}, in the polarized cold neutron capture by para-hydrogen. The goal is to measure A{sub {gamma}} with uncertainty of 0.5 x 10{sup -8}, 10% of its predicted value. A{sub {gamma}} primarily isolates the {Delta}I = 1 component of the hadronic weak interaction and thus will determine the long-range weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. The experiment is carefully designed for the LANSCE pulsed spallation neutron source to achieve the proposed statistical precision and to control systematic errors. We discuss the experiment and its status.

2002-01-01

78

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

79

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

80

RF plasma nitriding of severely deformed iron-based alloys  

Energy Technology Data Exchange (ETDEWEB)

The effect of severe plastic deformation by cold high pressure torsion (HPT) on radio frequency (RF) plasma nitriding of pure iron, as well as St2K50 and X5CrNi1810 steels was investigated. Nitriding was carried out for 3 h in a nitrogen atmosphere at a pressure of 10{sup -5} bar and temperatures of 350 and 400 deg. C. Nitrided specimens were analysed by scanning electron microscopy (SEM), X-ray diffraction and micro hardness measurements. It was found that HPT enhances the effect of nitriding leading almost to doubling of the thickness of the nitrided layer for pure iron and the high alloyed steel. The largest increase in hardness was observed when HPT was combined with RF plasma nitriding at 350 deg. C. In the case of pure iron, the X-ray diffraction spectra showed the formation of {epsilon} and {gamma}' nitrides in the compound layer, with a preferential formation of {gamma}' at the ...

2003-05-15

81

Gamma heating in LMFBR media  

International Nuclear Information System (INIS)

State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method was developed to permit rapid, accurate ...

1976-01-01

82

[sup 3]He([ital n],[gamma])[sup 4]He cross section and the photodisintegration of [sup 4]He  

Energy Technology Data Exchange (ETDEWEB)

The absolute cross section of the [sup 3]He([ital n],[gamma])[sup 4]He reaction was measured at five energies between [ital E][sub [ital n

1993-11-01

84

CP Violation with Bs -> J/Psi phi at the Tevatron  

CERN Document Server

Recent results using B_s -> J/Psi phi decays for measuring the CP violating phase, phi_s, and the decay width difference for the two mass eigenstates, Delta Gamma_s, are presented from the CDF and D0 experiments at the Fermilab Tevatron collider.

2011-01-01

85

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01

86

Production of scalar Higgs and pseudoscalar Higgs in multi-Higgs doublet models at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process {gamma}{gamma}{yields}tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future {gamma}{gamma} colliders for small values of tan {beta}. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)

2000-05-01

87

Production of scalar Higgs and pseudoscalar Higgs in multi-Higgs doublet models at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process #gamma##gamma##->#tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future #gamma##gamma# colliders for small values of tan #beta#. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)

2000-05-01

88

In-beam spectroscopy of nuclei  

International Nuclear Information System (INIS)

The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).

1982-01-01

89

The value of computed tomography in the diagnosis of grating scapula  

Energy Technology Data Exchange (ETDEWEB)

Snapping or grating scapula is a condition of the shoulder girdle in which the patient complains of pain and an audible snapping sound which may be associated with pain. We evaluated the diagnostic value of the computed tomography (CT) scans using the clinical diagnosis of a grating scapula as the gold standard. This retrospective study reports the sensitivity, specificity, likelihood ratio and receiver operator characteristic curve for the CT scans and the k value as a measure of the interobserver agreement. None of the parameters validated the examination. We therefore concluded that CT scans are inappropriate for differentiation between a grating scapula and a normally functioning shoulder except in cases where bony abnormalities are present. (orig.)

1994-07-01

90

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, ...

2010-01-01

91

Is energy imparted a good measure of the radiation risk associated with CT examinations  

International Nuclear Information System (INIS)

The dose distribution in a Rando phantom has been measured for typical EMI 5005 CT scans of the head, chest, abdomen and pelvis. These dose distributions have been used to generate quantitative estimates of the somatic and genetic radiation risks associated with these CT examinations and also to measure the total energy imparted during each scan. A comparison has been made between the radiation risk estimates and the energy imparted measurements. The energy imparted measurements are not a good indicator of the somatic and/or genetic risks when one type of CT scan is compared with another. However, for a given type of scan, the energy imparted may be a reasonable indicator of the relative somatic risks associated with different CT examinations. Considerable care should be taken when interpreting and using any ...

92

FFTF reactor-characterization program: gamma-ray measurements and shield characterization  

Science.gov (United States)

A series of experiments is to be made during the acceptance test program of the Fast Flux Test Facility (FFTF) to measure the gamma ray characteristics of the Fast Test Reactor (FTR) and to establish the performance characteristics of the reactor shield. These measurements are a part of the FFTF Reactor Characterization Program (RCP). Detailed plans have been developed for these experiments. During the initial phase of the Characteristics Program, which will be carried out in the In-Reactor Thimble (IRT), both active and passive measurement methods will be employed to obtain as much information concerning the gamma ray environment as is practical. More limited active gamma ray measurements also will be made in the Vibration Open Test Assembly (VOTA).

93

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 ...

1983-01-01

94

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 ...

7871-01-01

95

Measurements of radioactivity in Jamaican building materials and gamma dose equivalents in a prototype red mud house  

International Nuclear Information System (INIS)

Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.

96

Estimation of gamma-absorption method for measurement of layers thickness in multi-layers articles  

International Nuclear Information System (INIS)

Certain problems of gamma-absorption method of measuring the thickness of layers in multi-layer items are analyzed. Two examples of solving the above-mentioned problems have been considered. One of them deals with a two-layer item, its integral thickness being known or measured in advance, the second example is referred to a two-layer item with unknown integral value

97

Strengh functions of strontium 88 obtained from the analysis of the (#gamma#,n) reaction near the threshold  

International Nuclear Information System (INIS)

The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.

1987-09-14

98

Search for anisotropy in the L x-gamma angular correlations following the decay of "2"0"7Bi  

International Nuclear Information System (INIS)

An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).

99

Extraction of Kaon Formfactors from K->mu nu gamma Decay at ISTRA+ Setup  

CERN Document Server

The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).

2010-01-01

100

Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.

101

Effect of X- and gamma-rays on phenolic compounds from Maytenus aquifolium Martius  

International Nuclear Information System (INIS)

The effect of irradiation using several doses of X- and #gamma#-rays (10, 20, 40, 60, 80 and 100 kGy), upon total phenolic compounds contained in the leaves of Maytenus aquifolium Martius (Celastraceae) 'espinheira santa', was investigated. The content of phenolic compounds (measured by the Folin-Denis spectrophotometric method) was unaffected by X- or #gamma#-ray irradiation, at any dose. (author)

2005-06-01

102

Neutron and gamma-ray penetrations in thick iron  

Energy Technology Data Exchange (ETDEWEB)

Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron ...

1980-03-01

103

The supersymmetric quantum effects at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at {gamma}{gamma} colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R{sub p}-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)

2001-08-01

104

The supersymmetric quantum effects at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at #gamma##gamma# colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R_p-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)

2001-08-01

105

Spacecraft and Instruments - NASA  

Science.gov (United States)

Aerosol Polarimetry Sensor (APS) + Continuous along-track scanning ... side of the spacecraft and faces outward, measures the intensity of incoming solar ... on a larger rocket, and faced slightly different conditions in spaceinto Glory wasn't ...

106

Determination of Thermal Properties and Morphology of Eucalyptus Wood Residue Filled High Density Polyethylene Composites  

UK PubMed Central (United Kingdom)

Thermal behaviors of eucalyptus wood residue (EWR) filled recycled high density polyethylene (HDPE) composites have been measured applying the thermogravimetric analysis (TGA) and differential scanning...Full Text Available

110

Higgs, SUSY and the standard model at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

In this report, I surveyed physics potential of the {gamma}{gamma} option of a linear e{sup +}e{sup -} collider with the following questions in mind: What new discovery can be expected at a {gamma}{gamma} collider in addition to what will be learned at its 'parent' e{sup +}e{sup -} linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e{sup -} beams, we find that a {gamma}{gamma} collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e{sup -}e{sup -} system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a {gamma}{gamma} collider. CP property ...

2001-10-11

111

Higgs, SUSY and the standard model at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

In this report, I surveyed physics potential of the #gamma##gamma# option of a linear e"+e"- collider with the following questions in mind: What new discovery can be expected at a #gamma##gamma# collider in addition to what will be learned at its 'parent' e"+e"- linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e"- beams, we find that a #gamma##gamma# collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e"-e"- system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a #gamma##gamma# collider. CP property of the scalar sector can be explored in detail by ...

2001-10-11

112

Measurement of the photon-proton total cross section at a center-of-mass energy of 209 GeV at HERA  

Energy Technology Data Exchange (ETDEWEB)

The photon-proton total cross section has been measured in the process e{sup +}p{yields}e{sup +}{gamma}p{yields}e{sup +}X with the ZEUS detector at HERA. Events were collected with photon virtuality Q{sup 2}<0.02 GeV{sup 2} and average {gamma}p center-of-mass energy W{sub {gamma}}{sub p}=209 GeV in a dedicated run, designed to control systematic effects, with an integrated luminosity of 49 nb{sup -1}. The measured total cross section is {sigma}{sub tot}{sup {gamma}}{sup p}=174{+-}1 (stat.){+-}13 (syst.) {mu}b. The energy dependence of the cross section is compatible with parameterizations of high-energy pp and pp-bar data.

2002-04-15

113

Thyroidal uptake of iodine-123 in children using a gamma camera and computer  

Energy Technology Data Exchange (ETDEWEB)

The measurement of thyroidal uptake of radioiodine using a gamma camera and computer is described. In 12 children there was good agreement with simultaneous measurements using a probe, while in a further 14 patients the uptake values were consistent with the clinical diagnosis. The technique should be especially useful for infants and small children.

1985-10-01

114

Radon and radon daughter evaluation in a natural radioactivity survey indoors  

Energy Technology Data Exchange (ETDEWEB)

An indoor survey in order to estimate the population exposure in five towns of an Italian Region is presented. A particular methodology for the campaign was planned and is being applied. Gamma spectrometry of building materials, exposure rate measurements indoors and outdoors and radon concentration measurements indoors were taken with different techniques. A correlation was found between mean gamma exposure rate and mean radon concentration in the houses investigated. An evaluation of mean effective dose equivalents for the inhabitants of the five towns is reported.

1985-10-01

115

Gamma absorption determination of concentration in a three-component mixture  

International Nuclear Information System (INIS)

A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.

116

Determining the upper limit of Gamma_{ee} for the Y(4260)  

CERN Document Server

By fitting the R values between 3.7 and 5.0 GeV measured by the BES collaboration, the upper limit of the electron width of the newly discovered resonance Y(4260) is determined to be 240 eV at 90% C.L., together with the BABAR measurement on the product of Gamma_{ee} and BR(Y(4260) --> pi+pi- J/psi), this implies a large decay width of Y(4260) --> pi+pi- J/psi final states.

2006-01-01

117

Design concept and testing of an in-bundle gamma densitometer for subchannel void fraction measurements in the THTF electrically heated rod bundle  

International Nuclear Information System (INIS)

A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.

118

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer ...

1997-05-01

119

Semileptonic b to u transition  

CERN Document Server

Experimental studies of charmless semileptonic B decays can be broadly categorized into inclusive and exclusive measurements depending on how the final states are treated. The inclusive method measures the decay rate $\\Gamma(B \\to X_u \\ell \

2007-01-01

120

Historical estimates of external gamma exposure and collective external gamma exposure from testing at the Nevada Test Site. I. Test series through HARDTACK II, 1958  

Energy Technology Data Exchange (ETDEWEB)

In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite ...

1985-12-01

121

Forthcoming (n, #gamma#) measurements on the Fe and Ni isotopes at CERN n_TOF  

International Nuclear Information System (INIS)

An overview of the past, present and future research activities at the CERN neutron time of flight facility n_TOF is given, with special focus on the astrophysical aspects. During the first campaign (Phase I), neutron capture cross sections of relevance for several aspects of the s-process nucleosynthesis have been measured. A second campaign has recently started (Phase II), aiming at the study of the weak s-process component via accurate (n,#gamma#) measurements of the Fe and Ni isotopes. Some changes in the facility will allow us to perform these measurements with improved experimental conditions.

2010-01-01

122

Attention deficit hyperactivity disorder: binding of [{sup 99m}Tc]TRODAT-1 to the dopamine transporter before and after methylphenidate treatment  

Energy Technology Data Exchange (ETDEWEB)

Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gamma camera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with ...

2000-10-01

123

Microstructural evaluation of as-solidified and heat-treated [gamma]-TiAl based powders  

Energy Technology Data Exchange (ETDEWEB)

Powders with nominal compositions (in atomic percent) Ti-48Al and Ti-48Al-2Nb-2Cr were prepared by the plasma rotating electrode process (PREP) and gas atomization (GA) techniques. As-solidified and heat-treated (1000degC per 3 h) powder samples were examined by metallography, scanning electron microscopy, X-ray diffraction and transmission electron microscopy. The microstructures of the powders were characterized as a function of atomization technique, alloy content, powder particle size (solidification rate) and thermal history. All of the as-solidified powders were comprised of disordered [alpha], and ordered [alpha][sub 2]-Ti[sub 3]Al and [gamma]-TiAl. For both alloys, a larger volume fraction of [alpha] and [alpha][sub 2] was observed in the PREP powders relative to GA powders of comparable size. Additionally, for both alloys and both atomization techniques, the volume fraction of [alpha][sub 2] was observed to increase with decreasing ...

1992-05-15

124

RESUME-95: Results of an International Field Test of Mobile Equipment for Emergency Response  

DEFF Research Database (Denmark)

In 1995 the exercise RESUME-95 (Rapid Environmental Surveying Using Mobile Equipment) took place in Finland. Groups from 8 European countries joined the exercise. The methods used were airborne gamma-ray measurements, car-borne measurements and in situ stationary measurements. The results of the measurements are analyses aiming at disclosing similarities and differences between groups and measuring techniques.

1997-01-01

125

PROBING NEAR-SURFACE ATMOSPHERIC TURBULENCE WITH LIDAR MEASUREMENTS AND HIGH-RESOLUTION HYDRODYNAMIC MODELS  

Energy Technology Data Exchange (ETDEWEB)

As lidar technology is able to provide fast data collection at a resolution of meters in an atmospheric volume, it is imperative to promote a modeling counterpart of the lidar capability. This paper describes an integrated capability based on data from a scanning water vapor lidar and a high-resolution hydrodynamic model (HIGRAD) equipped with a visualization routine (VIEWER) that simulates the lidar scanning. The purpose is to better understand the spatial and temporal representativeness of the lidar measurements and, in turn, to extend their utility in studying turbulence fields in the atmospheric boundary layer. Raman lidar water vapor data collected over the Pacific warm pool and the simulations with the HIGRAD code are used for identifying the underlying physics and potential aliasing effects of spatially resolved lidar measurements. This capability also helps improve the trade-off between ...

2000-11-01

126

Neutron intensity measurements of BWR spent fuels  

International Nuclear Information System (INIS)

A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)

2000-03-01

127

Beam Profile Measurement and its Application to Calculate Beam Emittance Using Wire Scanner for the PEFP 20MeV linac  

International Nuclear Information System (INIS)

A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed

2010-10-01

128

Nondestructive techniques for the control of conditioned radioactive wastes  

International Nuclear Information System (INIS)

The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.

2005-09-01

130

Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube  

International Nuclear Information System (INIS)

This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR ...

1985-04-25

131

Decays of "8"8Kr and "8"8Rb  

International Nuclear Information System (INIS)

The #gamma# rays following the #beta# decays of "8"8Kr and "8"8Rb have been studied, using both large volume Ge(Li) detectors for singles and coincidence measurements and anti-Compton spectrometry for singles measurements. Level schemes for "8"8Rb and "8"8Sr were constructed from the data and 74 of 81 #gamma# rays observed in the decay of "8"8Kr were placed in the "8"8Rb level scheme with 23 excited states. For the decay of "8"8Rb, all of the observed 27 #gamma# rays have been placed in the (well known) level structure of "8"8Sr. Spin and parity assignments have been deduced from #beta#-decay logft values and #gamma#-ray transition patterns. Possible shell model interpretations are presented for the level schemes.

132

The uterine blush. A potential false-positive in Meckel's scan interpretation  

Energy Technology Data Exchange (ETDEWEB)

To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative ...

1982-10-01

133

Imaging of dialysis-related amyloid (AB-amyloid) deposits with sup 131 I-beta 2-microglobulin  

Energy Technology Data Exchange (ETDEWEB)

The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that ...

1990-12-01

134

Measurement of the triple gauge-boson couplings {gamma}WW and ZWW in ALEPH and at LEP; Mesure des couplages {gamma}WW et ZWW dans ALEPH et au LEP  

Energy Technology Data Exchange (ETDEWEB)

This document deals with the couplings between the W boson and Z and gamma particles. WWZ and WW{gamma} vertex are predicted by the electroweak theory based on the symmetry group SU(2){sub L}*U(1){sub Y}, their existence is confirmed by the measurement of the production cross-section of W pairs at LEP. The effective values of the couplings are modified by the introduction of standard model particle loops at the vertex level, the impact on the coupling value is assessed to reach 10{sup -3}. These loops can also include beyond-the-standard-model particles, their impact is in the magnitude order of 10{sup -3} for most models. The fully description of these loops requires the values of 14 complex parameters whose measurement will give information about the existence of new particles. Nevertheless the number of events at LEP is not sufficient to measure all the parameters simultaneously. ...

2005-03-15

135

Inf-convolution of g_\\Gamma-solution and its applications  

CERN Document Server

A risk-neutral method is always used to price and hedge contingent claims in complete market, but another method based on utility maximization or risk minimization is wildly used in more general case. One can find all kinds of special risk measure in literature. In this paper, instead of using market modified risk measure, we use a kind of risk measure induced by g_\\Gamma-solution or the minimal solution of a Constrained Backward Stochastic Differential Equation (CBSDE) directly when constraints on wealth and portfolio process comes to our consideration. Such g_\\Gamma-solution and the risk measure generated by it is well defined on appropriate space under suitable conditions. We adopt the inf-convolution of convex risk measures to solve some optimization problem. A dynamic version risk measures defined through ...

2011-01-01

136

Kaluza-Klein Effects on Higgs Physics in Universal Extra Dimensions  

Energy Technology Data Exchange (ETDEWEB)

We examine the virtual effects of Kaluza-Klein (KK) states on Higgs physics in universal extra dimension models. We study the partial widths {Lambda}{sub h{yields}gg}, {Lambda}{sub h{yields}{gamma}{gamma}}, and {Lambda}{sub h{yields}{gamma}Z}, which are relevant for Higgs production and detection in future collider experiments. These interactions occur at one loop in the Standard Model, as do the KK contributions. We find that the deviations induced by the KK exchanges can be significant; for one extra dimension, the gg {yields} h production rate is increased by 10% - 85% for the mass of the first KK state in the range 500 {approx}> m{sub 1} {approx}> 1500 GeV, a region untested by current direct search and precision measurement constraints. The h {yields} {gamma}{gamma} decay width is decreased by {approx}< 20% in the same mass range. For two or more universal extra dimensions the ...

2002-04-05

137

Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02  

Energy Technology Data Exchange (ETDEWEB)

Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from ...

2004-12-15

138

A Measurement of the Spatial Distribution of Diffuse TeV Gamma Ray Emission from the Galactic Plane with Milagro  

Energy Technology Data Exchange (ETDEWEB)

Diffuse {gamma}-ray emission produced by the interaction of cosmic-ray particles with matter and radiation in the Galaxy can be used to probe the distribution of cosmic rays and their sources in different regions of the Galaxy. With its large field of view and long observation time, the Milagro Gamma Ray Observatory is an ideal instrument for surveying large regions of the Northern Hemisphere sky and for detecting diffuse {gamma}-ray emission at very high energies. Here, the spatial distribution and the flux of the diffuse {gamma}-ray emission in the TeV energy range with a median energy of 15 TeV for Galactic longitudes between 30{sup o} and 110{sup o} and between 136{sup o} and 216{sup o} and for Galactic latitudes between -10{sup o} and 10{sup o} are determined. The measured fluxes are consistent with predictions of the GALPROP model everywhere except for the Cygnus region (l ...

2008-05-14

139

Tritium monitor with improved gamma-ray discrimination  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.

1985-01-01

140

Parity nonconservation in "2"0"7Pb  

International Nuclear Information System (INIS)

Two experiments are currently underway to measure the single-particle weak mixing matrix element for the 1064 KeV transition in "2"0"7Pb. One experiment measures the circular polarization of the 1064 KeV gamma ray emitted from an unpolarized source, while the other experiment measures the forward-backward asymmetry of gamma rays emitted from a polarized source. Analysis of the first set of polarized source data yields an upper limit of 46 eV for the single-particle weak mixing matrix element. copyright 1995 American Institute of Physics.

141

Choice of distance from radiation source to tested object for gamma-absorption density measurer in divergent pencil of ray  

International Nuclear Information System (INIS)

Formulae are derived for estimation of the effect of gamma beam divergence on the value of systematic and statistical components of the errors of density measurement in production of structural materials and products also in the process of exploitation of building structures and constructions. Engineering technique for choice of the distance between radiation source and object under test is developed for absorption radioisotope densimeter operating by the scheme of geometry of divergent beam with amplitude compensation of backscattered radiation effect. The assessment of radioisotope densimeter efficiency providing the error of density measurement prescribed at design stage

142

Precise measurement of a focused ion beam profile  

Energy Technology Data Exchange (ETDEWEB)

The profile of focused boron ion beam (FIB) from a liquid metal ion source was determined by MOS device characteristics and resist exposure experiments. A focused boron ion beam was line-scanned into the middle of the channel region along the source to drain direction of a MOSFET, and the effective channel width is determined from electrical measurements. PMMA resist was also exposed by a line-scanned boron FIB and the developed contour was observed by a SEM. The profile of the focused boron ion beam with a diameter of around 0.2 ..mu..m was determined by these two methods and it was found to have about a 1 ..mu..m wide tail at around three orders of magnitude below the peak current density region. The profile difference between the two measurements are attributed to the boron diffusion in silicon by subsequent heat-treatments during device fabrication.

1987-06-01

143

Estimated fetal radiation dose from multislice CT studies  

International Nuclear Information System (INIS)

It is often necessary to estimate the dose of radiation to a fetus from a series of CT scans. To assist in making this process easier and more accurate, we measured fetal doses in an adult anthropomorphic phantom for four CT scanners: Picker 1200, Siemens DRH, GE 9800, and GE 8800. Measurements were made at four kilovoltages (100, 120, 130, and 140 kVp), for 2-, 5-, 8-, and 10-mm thicknesses, for two scanning angles (360 degrees and 398 degrees) and for two patient orientations (prone and supine). The fetal-dose estimates are based on the CT dose index measured by using a pencil ionization chamber at the center position of a 16-cm-diameter cylindrical phantom. Comparison with data from other investigators shows reasonable agreement when phantom differences, X-ray tube output, and equipment calibration are considered.

144

Investigation of the "1"0"1Mo level and gamma-decay scheme by thermal neutron capture in "1"0"0Mo  

International Nuclear Information System (INIS)

The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).

1975-03-01

145

Influence of the micro-addition of Mo on glass forming ability and corrosion resistance of Cu-based bulk metallic glasses  

International Nuclear Information System (INIS)

(Cu_4_7Zr_1_1Ti_3_4Ni_8)_1_0_0_-_xMo _x bulk metallic glasses (BMGs) with x = 0, 1 and 2 at.% and a bulk metallic glass matrix composite with x = 5 at.% were successfully prepared by water-cooled copper mold casting. The effect of the addition of a small amount of Mo on the glass forming ability (GFA), thermal properties of the base alloy (i.e. x = 0) were investigated by X-ray diffraction (XRD), differential scanning calorimetry (DSC) and differential thermal analyzer (DTA). It is found that the addition of appropriate amount of Mo can enhance the GFA of the Cu-based BMG, as indicated by the increase in the reduced glass transition temperature T _r_g (=T _g/T _l) and the parameter #gamma# (=T _x/(T _g + T _l)) with the increase of Mo. On the other hand, the corrosion resistance of the Cu-based BMGs with different Mo contents was examined by electrochemical polarization and weight loss measurement in 1 mol/L H_2SO_4 and 1 ...

2006-05-05

146

Temperature measurements via narrow line laser absorption of carbon dioxide  

Energy Technology Data Exchange (ETDEWEB)

Theoretical development for temperature measurements via narrow line, infrared absorption of carbon dioxide (CO{sub 2}) is presented. The proposed technique is based on rapid-scanning of two adjacent absorption line shapes. Spectroscopic considerations for sensitivity to temperature measurements are discussed. Several line pairs are evaluated, and the R(58) and R(60) transitions of the (00{sup 0}1){l_arrow}(00{sup 0}0) band are suggested for use in high temperature measurements for combustion systems.

1996-12-31

147

Scanning Electron Microscope Examination of Cotton Linters ...  

Science.gov (United States)

... TECHNICAL REPORT ARBRL-TR-02476 SCANNING ELECTRON MICROSCOPE ... SCANNING ELECTRON MICROSCOPE EXAMINATION OF ...

1983-03-01

148

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

149

Measurement of the parity violating asymmetry A{sub {gamma}} in n{yields}+p{yields}d+{gamma}  

Energy Technology Data Exchange (ETDEWEB)

The weak interaction between neutrons and protons has never been resolved experimentally. In analogy with the strong NN interaction, the weak NN interaction at low energy can be parametrized in terms of a meson exchange model with parity violating meson-nucleon couplings. Unlike the measured proton-proton weak interaction, the neutron-proton weak interaction is sensitive to the weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. This coupling, which is responsible for the longest-ranged part of the weak NN interaction and is therefore an essential part of any description of weak interactions in nuclei, remains undetermined despite many years of effort. A measurement of the gamma ray directional asymmetry A{sub {gamma}} in the capture of polarized neutrons by parahydrogen has been proposed at Los Alamos National Laboratory. The goal of this experiment is to determine A{sub ...

2000-02-11

150

Production of three vector bosons in #gamma# #gamma# colliders  

International Nuclear Information System (INIS)

The production of three vector bosons in #gamma# #gamma# collisions studying the reactions #gamma# + #gamma# #-># W"+ + W"- + Z"0 and #gamma# + #gamma# #-># W"+ + W"- + #gamma#. 12 refs., 4 figs., 2 tabs.

151

Stabilization of measuring channel of reflective gamma thickness gage by light pulses from additional scintillator  

International Nuclear Information System (INIS)

Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.

152

Penetration effect in the M1 component of "1"7"7Ta #gamma#-transition with energy of 70.45 keV  

International Nuclear Information System (INIS)

The magnetic #beta#-spectrometer of the #pi# #sq root#2 type with 0.07% pulse resolution is used to measure the intensities of interval conversion electrons on L- and M-subshells of 70.45 keV "1"7"7 Ta gamma-transition. The results are analyzed and the values of mixing parameter #sigma#(E2/M1) and penetration parameter #lambda# are obtained.

153

Mass charge and angular momentum transfer in "1"0"6Cd + 255 MeV "5"4Fe collision studied by #gamma#-#gamma# coincidences  

International Nuclear Information System (INIS)

The distribution of mass, charge and angular momentum transfer among the products of 54-Fe (255 MeV) ions collisions with the 106 Cd target have been studied. The energy level schemes for 92-Mo, 60-Ni, 96-Ru and 56-Fe are presented. The production yields of different isotopes were also measured. 1 ref., 14 figs.

1991-12-01

154

Energy dependence of the yield of fission isomers in the /sup 241/Am(n,. gamma. ) and /sup 243/Am(n,. gamma. ) reactions  

Energy Technology Data Exchange (ETDEWEB)

Ratio of the fissile isomers and prompt fissions yields has been measured in processes of neutron capture by /sup 241/Am and /sup 243/Am nuclei in the neutron energy interval from 0.2 up to 1.3 MeV. The present data and the previous results suggest that the fission Am isomers are spin structure isomers rather than shape isomers.

1984-11-01

155

Decay scheme data for [sup 101]Mo and [sup 101]Tc  

Energy Technology Data Exchange (ETDEWEB)

New measurements of relative gamma-ray emission probabilities in the decay of [sup 101]Mo and [sup 101]Tc are reported. Previously published conversion-electron data have been used along with the gamma-ray data to formulate self-consistent decay schemes. (orig.)

1993-10-01

156

Decay scheme data for "1"0"1Mo and "1"0"1Tc  

International Nuclear Information System (INIS)

New measurements of relative gamma-ray emission probabilities in the decay of "1"0"1Mo and "1"0"1Tc are reported. Previously published conversion-electron data have been used along with the gamma-ray data to formulate self-consistent decay schemes. (orig.).

157

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

158

Can simulation measurements be used to predict the irradiated lung volume in the tangential fields in patients treated for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

A simple method of estimating the amount of lung irradiated in patients with breast cancer would be of use in minimizing lung complications. To determine whether simple measurements taken at the time of simulation can be used to predict the lung volume in the radiation field, we performed CT scans as part of treatment planning in 40 cases undergoing radiotherapy for breast cancer. Parameters measured from simulator films included: (a) the perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall at the center of the field (CLD); (b) the maximum perpendicular distance from the posterior tangential field edge to the posterior part of the anterior chest wall (MLD); and (c) the length of lung (L) as measured at the posterior tangential field edge on the simulator film. CT scans of the chest were performed with the patient in the ...

1990-01-01

159

Polymers and paper as packaging materials of irradiated food  

International Nuclear Information System (INIS)

Effects of #gamma#-irradiation on synthetic polymers and paper used as packaging materials for irradiated food have been studied by NMR. Polystyrene, polybutadiene and some copolymers were studied before and after the #gamma#-irradiation treatment and in the presence or absence of antioxidants and stabilisers. In the absence of additives, the effect of #gamma#-irradiation on polystyrene is negligible even irradiating at high doses. In turn, the role of antioxidants and stabilisers is crucial in polybutadiene and butadiene-containing copolymers. Wood pulp paper was also studied by NMR. Preliminary measurements on #gamma#-irradiated wood pulp sheets show a shortening in the T_2 relaxation time component due to the bound water, i.e. some of the bound water is lost. (author)

2000-03-01

160

Neutron star evolution and emission  

Science.gov (United States)

This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.

1997-08-01

161

Levels in sup 152 Gd and sup 152 Sm populated by the decay of sup 152 Eu  

Energy Technology Data Exchange (ETDEWEB)

The energy level schemes of {sup 152}Gd and {sup 152}Sm have been established on the basis of single gamma-spectra, and gamma-gamma coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/beta{sup +} and beta{sup -} decays of {sup 152}Eu to {sup 152}Sm and {sup 152}Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).

1990-01-01

162

Levels in "1"5"2Gd and "1"5"2Sm populated by the decay of "1"5"2Eu  

International Nuclear Information System (INIS)

The energy level schemes of "1"5"2Gd and "1"5"2Sm have been established on the basis of single #gamma#-spectra, and #gamma#-#gamma# coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/#beta#"+ and #beta#"- decays of "1"5"2Eu to "1"5"2Sm and "1"5"2Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).

1990-01-01

163

High resolution gamma-ray spectrometry of culverts containing transuranic waste at the Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.

1990-01-01

164

High resolution gamma-ray spectrometry of culverts containing transuranic waste at the Savannah River Site  

Energy Technology Data Exchange (ETDEWEB)

A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.

1990-12-31

165

Radon emanation and soil moisture effects on airborne gamma-ray measurements  

Energy Technology Data Exchange (ETDEWEB)

A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was ...

1997-09-01

166

Radon emanation and soil moisture effects on airborne gamma-ray measurements  

International Nuclear Information System (INIS)

A theoretical model is developed to explain variations in airborne gamma-ray measurements over a calibration range near Ottawa, Ontario. The gamma-ray flux from potassium and the thorium decay series showed an expected decrease with increasing soil moisture. However, the gamma-ray flux from the uranium decay series was highest in the spring when the ground was water-saturated and even covered with snow. These results are explained through the build-up of radon and its associated gamma-ray-emitting decay products in the clay soil of the calibration range with increasing soil moisture. Similar results were found from airborne measurements over other clay soils. However, measurements over sandy soils showed that the count rates from all three radio elements increased with decreasing soil moisture. This difference between soil types was ...

167

Width of the 1.836-MeV level in "8"8Sr  

International Nuclear Information System (INIS)

Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2"+_1 level in "8"8Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.

168

Terminal-differential algorithm for identification of local non homogeneity in article  

International Nuclear Information System (INIS)

Terminal-differential algorithm for identification of local nonhomogeneities in items under control is developed on the basis of measurements of X-ray or gamma-radiation weakening. The algorithm may be applied by developing radiation schemes of nondestructive control, identifying inadmissible inclusions in the object under study

169

Estimation of dry rubber content in natural rubber latex by differential scanning calorimetry  

British Library Electronic Table of Contents (United Kingdom)

Differential Scanning Calorimetry (DSC) is employed to study the changes in enthalpy of natural rubber latex samples when heated under a controlled temperature program. It is found that the mass normalized areas of the DSC curves between room temperature and 170??C for different latex samples are inversely proportional to the dry rubber content (DRC) of the samples, measured following the weighing and drying method. The changes in total enthalpy of the samples in this temperature range are interpreted as due to the variations in the quantity of water present in the samples. The measurements have been repeated by diluting selected samples with known quantities of water, and it is found that the normalized areas of the DSC curves are directly proportional to the amount of water added to the ...

2010-01-01

170

Chemical, electrical and electrochemical characterization of hybrid organic/inorganic polypyrrole/PW12O40^3^- coating deposited on polyester fabrics  

British Library Electronic Table of Contents (United Kingdom)

A study of the stability of conducting fabrics of polyester (PES) coated with polypyrrole/PW12O40^3^- (organic/inorganic hybrid material) in different pH solutions (1, 7, 13) has been done. Washing tests were also done in views of its possible application in electronic textiles such as antistatic clothing. X-ray photoelectron spectroscopy (XPS) studies have been done to quantify the amount of counter ion that remains in the polymer matrix and determine the doping ratio (N^+/N) after the different tests. Scanning electron microscopy (SEM) was also used to observe morphological differences after the different tests. Surface resistivity changes were measured by means of electrochemical impedance spectroscopy (EIS). Scanning electrochemical microscopy (SECM) was employed to measure changes in ...

2011-01-01

171

Single Higgs-boson production at a photon-photon collider: general 2HDM versus MSSM  

CERN Document Server

We revisit the production of a single Higgs boson from direct \\gamma \\gamma -scattering at a photon collider. We compute the total cross section \\sigma(\\gamma \\gamma \\to h) (for h=h0, H0, A0), and the strength of the effective g_{h \\gamma \\gamma} coupling normalized to the Standard Model (SM), for both the general Two-Higgs-Doublet Model (2HDM) and the Minimal Supersymmetric Standard Model (MSSM). In both cases the predicted production rates for the CP-even (odd) states render up to 10^4 (10^3) events per 500 \\invfb of integrated luminosity, in full consistency with all the theoretical and phenomenological constraints. Depending on the channel the maximum rates can be larger or smaller than the SM expectations, but in most of the parameter space they should be well measurable. We analyze how these departures depend on the dynamics ...

2011-01-01

172

Proton-neutron interaction in odd--odd indium nuclei  

International Nuclear Information System (INIS)

Low-lying nuclear energy levels in "1"1"0In and "1"1"2In were determined from de-excitation #gamma#-rays produced with "1"0"7Ag(#alpha#,n#gamma#)-"1"1"0In, "1"0"8Pd("6Li,4n#gamma#)"1"1"0In, "1"0"9Ag(#alpha#,n#gamma#)"1"1"2In and "1"1"0Pd("6Li,4n#gamma#)"1"1"2In reactions. In addition, the "1"1"4In energy level structure was investigated with the "1"1"0Pd("7Li,3n#gamma#)"1"1"4In reaction. Properties of de-excitation #gamma#-rays were determined from #gamma#-#gamma# coincidence, excitation, and angular distribution measurements conducted with Ge(Li) and Ge(intr.) #gamma#-ray detectors. A sequence of intraconnected levels in each of "1"1"0,"1"1"2,"1"1"4In were assigned to the (#pi#g"-"1/sub 9/2/, #nu#h/sub 11/2/) configuration. For the "1"1"0,"1"1"2,"1"1"4In energy level schemes a ...

1977-01-01

173

Proton-neutron interaction in odd--odd indium nuclei  

International Nuclear Information System (INIS)

An experimental study was performed in order to study the nuclear structure in odd--odd In isotopes. Low lying nuclear energy levels in "1"1"0In and "1"1"2In were determined from de-excitation #gamma#-rays produced with "1"0"7AG(#alpha#,n#gamma#)"1"1"0In, "1"0"8Pd("6Li,4n#gamma#)"1"1"0In, "1"0"9Ag(#alpha#,n#gamma#)"1"1"2In and "1"1"0Pd("6Li,4n#gamma#)"1"1"2In reactions. In addition, the "1"1"4In energy level structure was investigated with the "1"1"0Pd("7Li,3n#gamma#)"1"1"4In reaction. Properties of de-excitation #gamma#-rays were determined from #gamma#--#gamma# coincidence excitation and angular distribution measurements conducted with Ge(Li) and Ge(intr.) #gamma#-ray detectors. A sequence of intraconnected levels in each of "1"1"0 "1"1"2 "1"1"4In were assigned to the ...

1977-01-01

174

Observation of $X(3872)\\to J/\\psi \\gamma$ and search for $X(3872)\\to\\psi'\\gamma$ in B decays  

CERN Document Server

We report a study of $B\\to (J/\\psi \\gamma) K$ and $B\\to (\\psi' \\gamma)K$ decay modes using $772\\times 10^{6}$ $B\\bar{B}$ events collected at the \\Upsilon(4S)$ resonance with the Belle detector at the KEKB energy-asymmetric $e^+ e^-$ collider. We observe $X(3872) \\to J/\\psi \\gamma$ and report the first evidence for $\\chi_{c2} \\to J/\\psi \\gamma$ in $B\\to (X_{c\\bar{c}}\\gamma) K$ decays, while in a search for $X(3872) \\to \\psi' \\gamma$ no significant signal is found. We measure the branching fractions, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) \\mathcal{B}(X(3872) \\to J/\\psi\\gamma)$ $=$ $(1.78^{+0.48}_{-0.44}\\pm 0.12)\\times 10^{-6}$, $\\mathcal{B} (B^{\\pm} \\to\\chi_{c2} K^{\\pm})$$=$ $(1.11^{+0.36}_{-0.34} \\pm 0.09) \\times 10^{-5}$, $\\mathcal{B}(B^{\\pm} \\to X(3872) K^{\\pm}) ...

2011-01-01

175

CP property of the Higgs at the #gamma##gamma# colliders using tt-bar production  

International Nuclear Information System (INIS)

We present results of an investigation to study CP violation in the Higgs sector in tt-bar production at a #gamma##gamma#-collider, via the process #gamma##gamma# #-># #phi# #-># tt-bar where the #phi# is a scalar with indeterminate CP parity. The study is performed in a model independent way parametrising the CP violating couplings in terms of six form factors #left brace#R(S_#gamma#), T(S_#gamma#), R(P_#gamma#), T(P_#gamma#), S_t, P_t#right brace#. The CP violation is reflected in the polarisation asymmetry of the produced top quark. We use the angular distribution of the decay lepton from t/t-bar as a diagnostic of this polarisation asymmetry and hence of the CP mixing, after showing that the asymmetries in the angular distribution are independent of any CP violation in the tbW vertex. We construct combined asymmetries in the initial state lepton ...

2003-09-01

176

Simultaneous measurement of the neutron capture and fission yields of "2"3"3U  

International Nuclear Information System (INIS)

We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)

2007-04-22

177

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

178

Choice of energies in gamma-absorption method for layers thickness measuring of two-layers articles  

International Nuclear Information System (INIS)

Empirical formulae are proposed for the description of relation between optimum energies minimizing the mean-weighted error of gamma absorption measurement of the thickness of layers in two-layer products with the thickness of every layer from 30 up to 150 mm by carbon. Error of informational parameter approximation with the application of tables does not exceed 10% in case of non-accurate assessment of layers thickness not exceeding 2.5%. Generalized equation is derived which binds main parameters of the task and permits to choose optimum energies with the accuracy sufficient for practical purposes

179

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

180

Achievements in testing of the MGA and FRAM isotopic software codes under the DOE/NNSA-IRSN cooperation of gamma-ray isotopic measurement systems  

Energy Technology Data Exchange (ETDEWEB)

DOE/NNSA and IRSN collaborated on a study of gamma-ray instruments and analysis methods used to perform isotopic measurements of special nuclear materials. The two agencies agreed to collaborate on the project in response to inconsistencies that were found in the various versions of software and hardware used to determine the isotopic abundances of uranium and plutonium. IRSN used software developed internally to test the MGA and FRAM isotopic analysis codes for criteria used to stop data acquisition. The stop-criterion test revealed several unusual behaviors in both the MGA and FRAM software codes.

2009-01-01

181

Studies on energy level schemes of some nuclei by Gamma-ray spectroscopy  

International Nuclear Information System (INIS)

several authors tried to drive codes to construct nuclear level scheme of nuclei using a set of measured gamma -ray transitions and known energy levels, Ritz combination principle proved to be useful in constructing a more complete decay scheme. In this thesis the energy level schemes of some nuclei have been investigated by the measurements of the gamma - ray energies and use of Ritz combination code. The nuclei under investigation are "110m Ag (253 d)"110 Cd and "166m Ho (1200 yr) "166 E r. On the basis of the suggested level at 2249.02 keV by the Ritz code new positions of the two gamma-ray transitions at 677.5 and 706.6 KeV are found in decay scheme of "110m Ag. Also by this code, new position for the 994.84 KeV gamma-ray transition were established to depopulate the level at 1075.2 KeV.

1984-01-01

182

Neutron capture therapy beam on the LVR-15 reactor  

Energy Technology Data Exchange (ETDEWEB)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The ...

1992-01-01

183

Neutron capture therapy beam on the LVR-15 reactor  

International Nuclear Information System (INIS)

Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The ...

1991-10-01

184

Single parameter analysis of hysteretic magnetic flux trapping in high T{sub c} superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high {Tc} superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-10-01

185

Single parameter analysis of hysteretic magnetic flux trapping in high T_c superconductor ribbon  

International Nuclear Information System (INIS)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high T_c superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-07-19

186

Single parameter analysis of hysteretic magnetic flux trapping in high T[sub c] superconductor ribbon  

Energy Technology Data Exchange (ETDEWEB)

This paper described the application of an AC surface probe, similar to presently used eddy current probes, to the measurement of DC transport critical currents and critical state dissipation in high [Tc] superconductors. It has been shown that the probe can provide quantitative measurement of the full field penetration in superconducting samples by measuring the response of AC induced screening currents for superconducting materials in the form of tapes with overlayers of silver. In this manner, the AC probe can be used to replace the contact DC probe for determining critical currents in a noncontacting and local manner suitable for scanning over or along the sample.

1992-01-01

187

Some tests on measuring methods for indoor radon using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Two methods for measuring indoor radon concentrations using activated charcoal have been tested. The first method is the well-known technique with direct gamma-measurements on the exposed canister after the sampling period. The other method uses a thermoluminescence dosemeter placed in the charcoal canister, giving an integrated value of the radon concentration.

1985-10-01

188

Use of portable HPGE detector and multichannel analyzer for in-situ gamma spectrometry of soil  

International Nuclear Information System (INIS)

Measurement of fission and activation products in the soil or over a plane grass land of a nuclear power station environment is required to find out the long term changes. The inventory of radionuclides in the soil is routinely determined by soil sampling, processing and gamma spectrometry in the laboratory. The method although is proven and accurate is time consuming and largely dependent on homogenous distribution. Therefore, an alternative and rapid method of in-situ gamma spectrometry using portable devices was standardized to determine the concentration of radionuclides in soil, for regular environmental monitoring as well as during emergency condition. The paper presents the methodology, ready to use factors and compares the results of a few measurements made in the environment of Tarapur Atomic Power Station by both in-situ and laboratory methods. (author)

2005-11-23

189

3-dimensional observations of atmospheric variables during the field campaign COPS  

Energy Technology Data Exchange (ETDEWEB)

The Convective and Orographically-induced Precipitation Study (COPS) has the aim to advance the quality of forecasts of orographically-induced precipitation in complex terrain. COPS is a Research and Development Project of the World Weather Research Program and considered to be one of the largest field campaigns on quantitative precipitation forecasting that has been performed so far. A network of state-of-the-art active and passive remote sensing systems was combined with in total 10 airborne platforms, Meteosat rapid scans and dense networks of standard meteorological instruments during the three months long field phase (June-August, 2007) in south-western Germany/eastern France to observe atmospheric variables in the three spatial dimensions and in time. By the University of Hohenheim, two novel ground-based mobile scanning lidar systems were deployed: a scanning rotational Raman lidar which provides combined ...

2008-05-01

192

Comparison of the e"+e"-, #gamma#e, #gamma##gamma# linear colliders  

International Nuclear Information System (INIS)

The possibility to transform the future linear e"+e"-colliders into the #gamma#e and #gamma##gamma# colliders with approximately the same energies and luminosities was shown earlier. Their properties are compared from the point of view of possible physical investigations on them. 10 refs.; 1 tab.

1992-06-02

193

$\\gamma/\\phi_3$ at hadron colliders  

CERN Document Server

$\\gamma/\\phi_3$ at hadron colliders

2011-01-01

194

"1"5"8Tm and "1"5"6Tm decays  

International Nuclear Information System (INIS)

These experiments were performed on the Isocele separator, on-line with the Orsay synchrocyclotron; thulium isotopes were produced by bombarding natural erbium targets with 150nA beam of 157MeV protons. Two Ge(Li) detectors, with resolution of 2.3 and 2.5keV at 1332keV used for #gamma#-ray measurements; conversion electron spectra were measured using a Si(Li) detector. #gamma# spectra, #gamma#-#gamma# coincidence and conversion electron measurements were sufficient to build the flow energy level schemes of the transitional "1"5"8Er and "1"5"6Er nuclei. On both nuclei several quasi rotational bands have been identified. These results are compared with other even erbium isotopes and with the neighboring N=88 and 90 isotones. Comparisons with predictions issued from some classical models are also performed: "1"5"8Er appears as a deformed nucleus very similar to ...

1976-01-01

195

{sup 48}Ti(n,xnpa{gamma}) reaction cross sections using spallation neutrons for E{sub n} = 1 to 20 MeV  

Energy Technology Data Exchange (ETDEWEB)

{gamma}-ray excitation functions have been measured for the interaction of fast neutrons with {sup 48}Ti (neutron energy from 1 MeV to 250 MeV). The Los Alamos National Laboratory spallation neutron source, at the LANSCE/WNR facility, provided a ''white'' neutron beam which is produced by bombarding a natural W target with a pulsed proton beam. The prompt-reaction {gamma} rays were measured with the large-scale Compton-suppressed Ge spectrometer, GEANIE. Neutron energies were determined by the time-of-flight technique. Excitation functions were converted to partial {gamma}-ray cross sections, taking into account the dead-time correction, the target thickness, the detector efficiency, and neutron flux (monitored with an in-line fission chamber). The data analysis is presented here for neutron energies between 1 to 20 MeV. Partial ...

2005-01-06

196

Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry  

International Nuclear Information System (INIS)

A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring ...

1977-11-01

197

Origin of {gamma}-rays from young open clusters  

Energy Technology Data Exchange (ETDEWEB)

The young open cluster Berkeley 87 was predicted to be associated with the COS B {gamma}-ray source 2CG 075+00 on the basis of the experimental evidence of the presence of a shock front around the Wolf - Rayet star ST3 placed in the inner part of the cluster. The CGRO phase-1 data confirm this identification. Protons accelerated at the shock boundary can produce {pi} deg. via p-p interactions and then {gamma}-rays. With the measured flux F{sub {gamma}} (E > 100 MeV) {approx_equal} 9x10{sup -7} ph cm{sup -2} s{sup -1} and the power-law proton spectrum with spectral index {gamma} = 2, the cosmic-ray-energy-density in the inner part ({approx} 0.8 pc radius) of Berk 87 is about 100 times greater than that in the vicinity of the Earth. We have calculated {gamma}-ray spectra expected from the decay of {pi}{sup d}eg. produced in p-p interactions. The spectra ...

1996-08-01

198

Molecules with polymerizable ligands as precursors to porous doped materials  

Energy Technology Data Exchange (ETDEWEB)

Titanium and aluminum alkoxide derivatives with polymerizable ligands such as 2-(methacryloyloxy)ethylacetoacetate (HAAEMA), oleic acid and geraniol (HOGE) have been obtained. The various compounds have been characterized by FT-IR and NMR {sup 1}H. Copolymerization with styrene and divinylbenzene affords porous doped organic materials which have been characterized by scanning electron microscopy (SEM), elemental analysis, density measurements.

1996-12-31

199

Dielectric barrier discharge using corona-modified silicone rubber  

Science.gov (United States)

Results from scanning electron microscopy, Fourier transform infrared spectroscopy and the measurement of thermally stimulated current show that a high density of the physical defects and the chemical defects are introduced into the surface of the silicone rubber plates after they are treated by corona discharge plasma. These defects behave electrically as shallow electron traps, leading to the formation of a uniform discharge in air at higher pressure when the corona-modified silicone rubber is used in dielectric barrier discharge.

2008-10-01

200

Automated bead-positioning system for measuring impedances of R-F cavity modes  

Energy Technology Data Exchange (ETDEWEB)

We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper.

1993-05-01

201

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, ...

1988-09-01

202

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in ...

1988-01-01

203

Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium  

International Nuclear Information System (INIS)

This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K_2YF_5_:Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with "1"3"7Cs gamma rays as well as with "9"0Sr/"9"0Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)

2011-02-01

204

Microstructural characterization of plasma nitrided austenitic stainless steel  

Energy Technology Data Exchange (ETDEWEB)

The microstructure of the layers produced by plasma nitriding austenitic stainless steel at different treatment temperatures (400 and 500 C) were studied by transmission electron microscopy (TEM) together with X-ray diffraction (XRD) and scanning electron microscopy (SEM). The results show that the microstructures were composed of 'expanded austenite' ({gamma}{sub N}) and {alpha}(ferrite)+CrN following plasma nitriding at lower and higher treatment temperatures, respectively. The former contains stacking faults and deformed twin substructures, while the latter is made up of colonies displaying a lamellar structure. Kurdjumov-Sachs or Nishiyama-Wassermann orientation relationships between the {alpha} and CrN layer were observed. (orig.)

2000-10-23

205

Application of a gamma spectroscopy system to the measurement of neutron cross sections necessary to the development of nuclear energy; Mise au point d'un systeme de spectroscopie pour mesurer des sections efficaces neutroniques applicables a un possible developpement du nucleaire comme source d'energie  

Energy Technology Data Exchange (ETDEWEB)

This work concerns the development of nuclear energy and nuclear waste management in particular. Two parts of this study can be distinguished. In the first part (theoretical), a thorium-plutonium fuel based on MOX and dedicated for PWR was investigated in order to transmute plutonium in a potentially low waste fuel cycle. It was shown that this type of fuel is not regenerative but could be used for a transition to the industrial thorium fuel cycle without building new reactors. Thanks to moderated neutron spectra and high loaded actinide mass in the core, U-233 is quickly created ({approx}300 kg/y) for a loss of about {approx}1200 kg of fissile plutonium. In the second part (experimental), we have developed and built a new reaction chamber to measure neutron cross sections of actinides by alpha-gamma spectroscopy. This experimental device (in principle transportable) was commissioned in the high flux reactor of ILL Grenoble. Neutron flux was ...

2002-09-01

206

First Observation of Radiative B^0 -> \\phi K^0 \\gamma Decays and Measurements of Their Time-Dependent CP Violation  

CERN Document Server

We report the first observation of the radiative decay B^0 -> \\phi K^0 \\gamma using a data sample of 772 x 10^6 B B-bar pairs collected at the \\Upsilon(4S) resonance with the Belle detector at the KEKB asymmetric-energy e^+e^- collider. We observe a signal of 37+/-8 events with a significance of 5.4 standard deviations including systematic uncertainties. The measured branching fraction is ${\\cal B}(B^0 -> \\phi K^0 \\gamma) = (2.74\\pm 0.60 \\pm 0.32) \\times 10^{-6}$, where the uncertainties are statistical and systematic, respectively. We also report the first measurements of time-dependent CP violation parameters: ${\\mathcal S}_{\\phi K_S^0 \\gamma} = +0.74^{+0.72}_{-1.05} (stat)^{+0.10}_{-0.24} (syst)$ and ${\\mathcal A}_{\\phi K_S^0 \\gamma} = +0.35 +/- 0.58 (stat)^{+0.23}_{-0.10} (syst)$. Furthermore, we measure ${\\mathcal ...

2011-01-01

207

Environmental, scanning electron and optical microscope image analysis software for determining volume and occupied area of solid-state fermentation fungal cultures  

British Library Electronic Table of Contents (United Kingdom)

Abstract Here we propose a software for the estimation of the occupied area and volume of fungal cultures. This software was developed using a Matlab platform and allows analysis of high-definition images from optical, electronic or atomic force microscopes. In a first step, a single hypha grown on potato dextrose agar was monitored using optical microscopy to estimate the change in occupied area and volume. Weight measurements were carried out to compare them with the estimated volume, revealing a slight difference of less than 1.5%. Similarly, samples from two different solid-state fermentation cultures were analyzed using images from a scanning electron microscope (SEM) and an environmental SEM (ESEM). Occupied area and volume were calculated for both samples, and the results obtained w...

2011-01-01

208

Heat capacity measurement of some breeder materials  

International Nuclear Information System (INIS)

Isobaric molar heat capacities of powder and microsphere form of Li2TiO3 (s) and powder form of LiAlO2 (s) and Li2ZrO3 (s) were measured using a heat flux type differential scanning calorimeter in the temperature range 320 - 870 K. Specific heat capacities of LiAlO2 (s) was found to be much larger compared to those of Li2TiO3 (s) and Li2ZrO3 (s). (author)

2009-01-07

209

Nuclear magnetic moment measurements through hyperfine interactions in highly stripped ions  

International Nuclear Information System (INIS)

Time-differential magnetic moment measurements on the first-excited Isup(#pi#)=2"+ states in "2"0Ne and "2"4Mg with mean lives of 1.0 and 2.1 ps, respectively are described. The lifetime of the latter state was determined simultaneously. A special detection geometry was designed to improve the experimental #gamma#-ray anisotropy measured with finite-size detectors. For "2"0Ne also a time-integral measurement with charge-state separation was performed. The necessary electronics circuitry built to perform these complicated measurements and the plunger assembly with laser interferometer are also described. A magnetic moment measurement of "2"2Ne(2_1"+) with tau=5.0 ps and transient field measurements at low and high recoil velocities are reported. A discussion of possible extensions of the techniques are given. (Auth.).

1975-09-15

210

Serum gamma-glutamyltransferase is associated with arterial stiffness in healthy individuals  

British Library Electronic Table of Contents (United Kingdom)

Summary Objective- Gamma-glutamyltransferase (GGT) has been reported to be useful in predicting cardiovascular disease. Arterial stiffness measured by brachial-ankle pulse wave velocity (baPWV) is not only a marker of vascular damage but a significant predictor of cardiovascular events. Gender difference has been reported in the association between GGT and baPWV. We assessed, therefore, the association between GGT and baPWV in a large population and determined whether there was gender difference. Design- This cross-sectional study was conducted at the Asan Medical Centre, Seoul, Republic of Korea. Subjects and measurements- Serum GGT, baPWV and conventional risk factors were measured in 10 988 apparently healthy subjects (7248 men, 3740 women) who participated in a routine health screening...

2011-01-01

211

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the ...

212

QCD corrections to top quark pair production in association with a photon at hadron colliders  

CERN Document Server

We compute QCD corrections to the production of a ttbar pair in association with a hard photon at the Tevatron and the LHC. This process allows a direct measurement of the top quark electromagnetic couplings that, at the moment, are only loosely constrained. We include top quark decays, treating them in the narrow width approximation, and retain spin correlations of final-state particles. Photon radiation off top quark decay products is included in our calculation and yields a significant contribution to the cross-section. We study next-to-leading order QCD corrections to the ppbar -> ttbar+gamma process at the Tevatron for the selection criteria used in a recent measurement by the CDF collaboration. We also discuss the impact of QCD corrections to the pp -> ttbar+gamma process on the measurement of the top quark electric charge at the 14 TeV LHC.

2011-01-01

213

Neutron capture cross sections for unstable nuclei in the mass 90 region derived from proton capture measurements. [Strength functions  

Science.gov (United States)

Experimental measurements were made of the production cross sections and energy distributions of gamma rays emitted when the stable targets /sup 88/Sr, /sup 89/Y and /sup 90/Zr are exposed to protons in the energy range 3 to 8 MeV. The data are being analyzed using a recent version of the Uhl statistical model code. One conclusion is that while the gamma-ray strength functions employed reproduce the proton capture cross sections, they do not achieve the same degree of hardness observed in the measured spectra. To do so, their lower energy regions must be modified; such changes, however, do not affect the capture cross sections. 7 references.

1978-09-01

214

Production of three vector bosons in {gamma} {gamma} colliders; Producao de tres bosons vetoriais em {gamma} {gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The production of three vector bosons in {gamma} {gamma} collisions studying the reactions {gamma} + {gamma} {yields} W{sup +} + W{sup -} + Z{sup 0} and {gamma} + {gamma} {yields} W{sup +} + W{sup -} + {gamma}. 12 refs., 4 figs., 2 tabs.

1994-12-31

215

Coupled neutron - #gamma#-ray diffraction: A method for accurate measurement of strains. Application to the study of the ferroelectric phase transition of KH_2PO_4  

International Nuclear Information System (INIS)

A method that employs simultaneous neutron and #gamma#-ray diffraction techniques is proposed for accurate measurements of strains with or without an applied electric field (0-100 kV m"-"1). Instead of an absolute determination of the position of the neutron Bragg peak, a relative measurement of the neutron and #gamma# peak positions is used and allows a determination of the lattice-parameter changes with an accuracy of within 2 x 10"-"6. This technique avoids systematic errors originating in sample rotations by taking advantage of a reference directly related to the crystal lattice. The method appears to be particularly important for crystals that exhibit structural phase transitions, as demonstrated by the measurement of the strain U_x_x in KH_2PO_4 crystals as a function of temperature and applied electric field. In this case the errors would amount to #+-#20%. The results ...

1987-12-01

216

Corrections for non-homogeneity of the sample in Moessbauer f-factor measurements  

Energy Technology Data Exchange (ETDEWEB)

We describe a procedure for correcting the systematic errors in the Moessbauer f-factor measurement due to non-homogeneous effective thickness of the sample. To be more precise, we show that, if the mass of the sample is determined by means of X- or {gamma}-ray absorption, it is possible to establish experimental conditions so that the error on f due to material non-homogeneity in the sample is minimized.

2002-06-01

217

Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically ...

2008-05-22

218

Development of food preservation and processing techniques by radiation  

International Nuclear Information System (INIS)

Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as genotoxicity, acute ...

1988-04-18

219

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, ...

1983-01-01

220

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the knee response, ...

1983-01-01

221

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee response, correcting ...

1983-01-01

222

Year-1 (heavy-ion) physics with CMS at the LHC  

International Nuclear Information System (INIS)

The plans for the CERN LHC heavy ion program in 2010 are for collisions of lead ions during the month of November at an energy about half of the final 5.5 TeV/nucleon. The advanced preparations are mostly for extrapolations of the measurements at the maximum energy previously available, Au + Au at 0.2 TeV/nucleon. Because of the large increase in energy, surprises can be expected. One new feature made possible by the increased energy and the excellent muon energy resolution of CMS will be the study of the yields of the excited states of the upsilon meson as a function of angle and centrality. Although the main emphasis will be on the QGP formed by the overlapping parts of the Pb ions, the spectator parts and the electromagnetic field outside of the ions, #gamma#-Pb and #gamma##gamma#, are also important.

2010-06-01

223

Studies on natural radioactivity of some egyptian building materials  

International Nuclear Information System (INIS)

Using high-resolution y-rays spectrometry, the natural radioactivity of 14 samples of natural and o manufactured Egyptian building materials have been investigated. The samples were collected from local market and construction sites. From the measured gamma-ray spectra, specific activities were determined. The radium equivalent activity in each sample was estimated. Radiological evaluations of these materials indicate that all materials meet the external gamma-ray dose limitation. Calculation of concentration indices by assuming a Markkanen room model is constructed from these materials, to find the excess gamma-ray dose taken over that received from the outdoors. The Austrian Standard ONORM S 5200 is used in testing the building materials.

2004-02-24

224

Studies of the low-lying levels in /sup 192/Pt and /sup 192/Os  

Energy Technology Data Exchange (ETDEWEB)

The energy level schemes of /sup 192/Os and /sup 192/Pt have been established on the basis of ..gamma..-..gamma.. coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and ..beta../sup -/ decays of /sup 192/Ir to /sup 192/Os and /sup 192/Pt, respectively. Thirteen new transitions and three new levels at 1146.95, 1237.35 and 1913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, ..cap alpha..(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition.

1985-02-01

225

Studies of the low-lying levels in "1"9"2Pt and "1"9"2Os  

International Nuclear Information System (INIS)

The energy level schemes of "1"9"2Os and "1"9"2Pt have been established on the basis of #gamma#-#gamma# coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and #beta#"- decays of "1"9"2Ir to "1"9"2Os and "1"9"2Pt, respectively. Thirteen new transitions and three new levels at 1,146.95, 1,237.35 and 1,913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, #alpha#(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition. (orig.).

1985-01-01

226

Recent results from BESIII  

CERN Document Server

Using about $226\\times 10^6$ $\\jpsi$ events and $106\\times 10^6$ $\\psi^{\\prime}$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider, the Dalitz plot of $\\etap \\to \\eta \\pi^+ \\pi^-$ decay is studied, the direct measurement of $a^{0}_{0}(980)-f_{0}(980)$ mixing is performed, $X(2120)$ and $X(2370)$ are observed in the $\\pi^+\\pi^-\\eta^\\prime$ invariant mass spectrum, $\\psi^{\\prime}\\to\\gamma\\pi^0$ and $\\psi^{\\prime}\\to\\gamma\\eta$ are observed for the first time, and the decays $\\chi_{cJ}\\to\\gamma V$ ($V=\\phi$, $\\rho^0$, $\\omega$) are studied.

2010-01-01

227

PHOTON-HADRON INTERACTIONS AT RHIC AND LHC ENERGIES.  

Energy Technology Data Exchange (ETDEWEB)

Heavy Ion Collisions at RHIC and LHC energies are potentially an interesting laboratory for the study of QED. In these collisions, a Heavy Ion in one beam sees a highly Lorentz contracted electric field due to an oncoming beam particle. The Electric field reaches a maximum value of E {approx_equal} {gamma}{sub eff} {center_dot} Z {center_dot} e/b{sup 2}, where the apparent Lorentz factor, {gamma}{sub eff} = 2 {center_dot} {gamma}{sub beam}{sup 2} - 1. The collision may be viewed in terms of a flux of photons colliding with a stationary ion target using the equivalent photon approximation, originally introduced by Fermi in 1924. We show that the cross section for Inelastic Electromagnetic Interactions of Heavy Ions are both calculable and have been measured in the first RHIC running period.

2002-03-01

228

Transverse polarization of top quarks produced at a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

At future [gamma][gamma] colliders copious production of [ital t] [bar t] pairs is possible. This would allow for a detailed investigation of the interactions involving the top quark. We propose some correlations which are sensitive to [ital t] [bar t] final state interactions and we compute the QCD and standard model Higgs boson contributions to these correlations. A correlation resulting from the QCD induced transverse polarization of top quarks is found to be sizable and measurable at a high energy [ital e][sup +][ital e][sup [minus

1995-03-01

229

Transverse polarization of top quarks produced at a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

At future {gamma} {gamma} colliders a massive production of tt-bar pairs is possible. This would allow a detailed investigation of the interactions involving the top quark. The authors propose some correlations which are sensitive to tt-bar final state interactions and compute the QCD and standard model Higgs boson contributions to these correlation. QCD-induced transverse polarization of top quarks is found to be sizeable and measurable at a high-energy e{sup +} e{sup -} collider with an integrated luminosity of 10(fb){sup -1} which is converted into a photon collider by backscattering of laser photons. 16 refs.

1995-10-01

230

Transverse polarization of top quarks produced at a photon-photon collider  

International Nuclear Information System (INIS)

At future #gamma##gamma# colliders copious production of t bar t pairs is possible. This would allow for a detailed investigation of the interactions involving the top quark. We propose some correlations which are sensitive to t bar t final state interactions and we compute the QCD and standard model Higgs boson contributions to these correlations. A correlation resulting from the QCD induced transverse polarization of top quarks is found to be sizable and measurable at a high energy e"+e"- collider, which is operated as a photon collider through backscattering of laser photons, at an integrated luminosity of 10 fb"-"1.

231

Three-dimensional data processing for time resolved gamma-ray spectrometry  

International Nuclear Information System (INIS)

A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method. (author)

232

Soil gamma ray spectrometry of the Buquira river basin, SP, Brazil; Gamametria de solos da bacia do rio Buquira, SP, Brazil  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactivity found in rocks and its evaluation been frequently used for studies of environmental geochemistry, particularly those of detection and control of pollutants and the consequent changes in environment after antropic interferences. In this work natural radioactivity in forty nine soil samples in the basin of Buquira river, at the Northeast region of Sao Paulo State, has been analysed and measured with a Ge-HP gamma ray spectrometer. A table with the most relevant results found in rocks is shown and discussed. (author)

2002-12-01

233

Radiation hardness of plastic scintillating fiber  

International Nuclear Information System (INIS)

We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).

234

Neutron activation analysis of trace elements in Japanese hormesis cosmetics  

International Nuclear Information System (INIS)

In Japan, cosmetics claiming hormesis effect are available through Internet. Although these cosmetics show the contents, they never mention the minor elements and radioactive sources. The existence of radioisotopes, however, was observed by measurements of the gamma-rays with a HPGe detector. In this study, in order to clarify the contents of trace elements, the hormesis cosmetics including radioactive sources were analyzed using INAA, PGAA and NAA with multiple gamma-ray detection (NAAMG). Nineteen elements were analyzed quantitatively in hormesis cosmetics by INAA, PGAA and NAAMG and 16 elements were detected qualitatively by SEM-EPMA. (author)

2008-12-01

235

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

236

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

237

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)

2002-01-01

238

Electron capture decay of sup 203 Pb  

Energy Technology Data Exchange (ETDEWEB)

Intensities of {gamma}-transitions emerging from the EC decay of {sup 203}Pb were measured precisely. The obtained relative {gamma}-intensities are 100%(279.2keV), 4.14+-0.08%(401.3keV) and 0.932+-0.022%(680.5keV). The 279.2 and 680.5keV level feeding {beta}-branching ratios were deduced to be 95.3+-0.1 and 4.7+-0.1% respectively. {sup 203}Pb is suggested for calibration purposes. (author).

1989-01-01

239

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

240

ESR spectra of radicals of gamma-irradiated wood and cellulose  

International Nuclear Information System (INIS)

Spectra of e.p.r. radicals in cellulose and timber gamma-irradiated at 77 and 300 K have been measured. Radiation yields and the kinetics of radicals accumulation have been studied. The effect of ionizing radiation on cellulose is the appearance of radicals resulting from rupture of C-H bonds in positions 1 and 4. Timber, additionally, forms ''lignin'' radicals. A mechanism of cellulose and timber radiolysis is suggested. ''Lignin''-type compounds present in timber protect polysaccharides from radiation-induced destruction.

241

$B \\to X_{s} \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ decays at LHCb  

CERN Document Server

\\lhcb is one of the four major experiments at the Large Hadron Collider (\\lhc) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavour hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiments. In this article, the \\lhcb prospects for such measurements with exclusive decays of the type $B \\to \\Xs \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ are presented.

2011-01-01

242

$B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ decays at LHCb  

CERN Document Server

LHC$b$ is one the four major experiments at the Large Hadron Collider (LHC) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavor hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiment. In this article, the LHC$b$ prospects for such measurement with exclusive decays of the type $B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ are presented.

2011-01-01

243

Optimization of X-ray energy resolution from a horizontally focused single-crystal monochromator  

Energy Technology Data Exchange (ETDEWEB)

A method has been developed to optimize the energy resolution of a horizontally focusing monochromator. The method consists of determining the optimum radius of curvature of the cylindrically bent monochromator crystal by minimizing the total diffracted X-ray flux measured through an X-ray absorption foil. When measured at an absorption edge a global minimum can be identified, which corresponds to the minimum energy band accepted along the entire length of the crystal. Experimental verification of this method has been validated by comparing X-ray fluorescent scans taken for a series of crystal curvatures and by directly measuring the X-ray beam profiles at the corresponding points. The actual optical configuration and asymmetric-cut parameter of the focusing monochromator on beamline X4C at the National Synchrotron Light Source are modeled and ray tracing simulations of the optical system are compared ...

2009-02-11

244

Assessment of MCNP-4B code using measurement data of Wolsung nuclear power plant 2  

International Nuclear Information System (INIS)

The benchmark calculations have been performed for MCNP-4B code using the measurement data of Wolsong nuclear power plant 2. In this study, the benchmark calculations have been performed for the criticality, boron worth, reactivity device worth, reactivity coefficient, and flux scan. Cross-section libraries were newly generated from ENDF/B-VI release 3 through NJOY97.114 data processing system and a three-dimensional full core model was developed for MCNP calculation. The simulation results have shown that the criticality is estimated within 4 mkn and the estimated reactivity worth of the control devices are generally consistent with the measurement data. In certain cases, the simulation results have shown large discrepancies against the measurement data, which will be sturdied further in the near future.

2001-05-01

245

Application of BGO scintillators to absolute measurement of neutron capture cross sections between 0.01 eV and 10 eV  

Energy Technology Data Exchange (ETDEWEB)

Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, ...

1997-07-01

246

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range ...

2001-06-17

247

Neutron cross section measurements using the ORELA: "6"0Ni(n,x), "4"0Ca(n,x), "2"2Ne(n,#gamma#), "1"8"9Os(n,n'), /sup 186,187,188,189/Os(n,x), "1"8"9Os(n,#gamma#), /sup 148,149,150/Sm(n,#gamma#), "1"7"9Ta(n,#gamma#), /sup 86,87,88/Sr(n,x), "4"0Ar(n,x), the stable tellurium isotopes (n,#gamma#) and "2"0"5Tl(n,x). Progress report, September 1, 1984-August 31, 1985  

International Nuclear Information System (INIS)

The research performed during this reporting period (9/1/84 to 8/31/85) resulted in: (1) publication of three papers; (2) presentation of an invited paper to the conference on ''Neutron-Nucleus Collisions: A Probe of Nuclear Structure''; (3) presentation of three contributed papers at APS meetings; and (4) preparation of three manuscripts, two of which are in the process of internal review at the Oak Ridge National Laboratory and are included with this report, and the third is being typed as this report is being written. The publications and papers deal with topics in both nuclear structure and astrophysics. Our efforts to study the systematic behavior of the optical model potential in the energy region just above neutron binding has been made substantially more reliable with the publication of a paper which discusses the accuracy of the methods used to average the measured scattering matrix. In the area of stellar nucleosynthesis, comparison of our model ...

248

Data of spleen-scintiscanning after splenectomy  

International Nuclear Information System (INIS)

In 65 adult rabbits of both sexes (2.5 to 6 kg) the following salvaging procedures were performed after simulated trauma: (1) Continuous suture line; (2) closure with fibrin sealant after temporary clamping; (3) hemisplenectomy with omental wrap; (4) suture fixation of fragments and slices of spleen tissue to the peritoneum; (5) suture fixation of spleen fragments to the omentum; (6) extraperitoneal subcutaneous transposition of spleen cubes. In addition, the likelihood of spontaneous splenosis was examined in a preliminary study involving 5 animals by introducing unattached spleen meal and fragments. Scanning was repeated 4 to 12 weeks postoperatively. The functional competence of minor parenchymal islands was also investigated with well counter measurements of organ and muscle tissue homogenates. Spontaneous splenosis after abdominal injuries was not found to be the rule. Salvaging procedures at the natural vascular hilus by sutures, fibrin ...

249

Excited leptons and quarks at #gamma##gamma#/#gamma#e colliders  

International Nuclear Information System (INIS)

We discuss the search of excited leptons and quarks with spin 1/2 at #gamma##gamma# and at #gamma#e colliders. We show that #gamma##gamma# colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l"*l#gamma# transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).

250

Yields of short-lived fission products produced following "2"3"5U(n_t_h,f)  

International Nuclear Information System (INIS)

Measurements of gamma-ray spectra, following the thermal neutron fission of "2"3"5U have been made using a high purity germanium detector at the University of Massachusetts Lowell (UML) Van de Graaff facility. The gamma spectra were measured at delay times ranging from 0.2 s to nearly 10000 s following the rapid transfer of the fission fragments with a helium-jet system. On the basis of the known gamma transitions, forty isotopes have been identified and studied. By measuring the relative intensities of these transitions, the relative yields of the various precursor nuclides have been calculated. The results are compared with the recommended values listed in the ENDF/B-VI fission product data base (for the lifetimes and the relative yields) and those published in the Nuclear Data Sheets (for the beta branching ratios). This information is particularly useful for ...

1998-08-01

251

Testing gravitational parity violation with coincident gravitational waves and short gamma-ray bursts  

CERN Document Server

Gravitational parity violation is a possibility motivated by particle physics, string theory and loop quantum gravity. One effect of it is amplitude birefringence of gravitational waves, whereby left and right circularly-polarized waves propagate at the same speed but with different amplitude evolution. Here we propose a test of this effect through coincident observations of gravitational waves and short gamma-ray bursts from binary mergers involving neutron stars. Such gravitational waves are highly left or right circularly-polarized due to the geometry of the merger. Using localization information from the gamma-ray burst, ground-based gravitational wave detectors can measure the distance to the source with reasonable accuracy. An electromagnetic determination of the redshift from an afterglow or host galaxy yields an independent measure of this distance. Gravitational parity violation would manifest ...

2010-01-01

252

Performance of the AMS-02 Experiment for High Energy Gamma Ray Astrophysics  

CERN Document Server

AMS is a particle detector designed to perform high precision measurements of the cosmic rays fluxes with the main goals of searching for anti-nuclei, as remnants of primordial anti-matter, and of measuring the faintest components of the cosmic flux, anti- protons, positrons and high energy photons. To fulfill the requirements of large acceptance, long exposure time and excellent particle identification needed to achieve the intended results, AMS will operate in space as an attached payload to the International Space Station (ISS), being the first full featured particle physics experiment to operate in the Earth orbit. The AMS-02 accurate measurements of cosmic-ray nuclei, protons, antiprotons, electrons and positrons will be completed by high energy gamma rays detection. The experiment will detect gamma-rays, either by reconstructing e+e? pairs generated by photons converted ...

2007-01-01

253

Modified Fragmentation Function in Heavy Ion Collisions at RHIC via Direct photon-Jet Measurements  

CERN Document Server

The presented results are the first measurements at RHIC for direct $\\gamma$-charged hadron azimuthal correlations in heavy ion collisions. We use these correlations to study the color charge density of the medium through the medium-induced modification of high-p$_T$ parton fragmentation. Azimuthal correlations of direct photons at high transverse energy (8 $<$ p$_T$ $<$ 16 GeV) with away-side charged hadrons of transverse momentum (3 $<$ p$_T$ $<$ 6 GeV/c) have been measured over a broad range of centrality for $Au+Au$ collisions and $p+p$ collisions at $\\sqrt{s_{NN}}$ = 200 GeV in the STAR experiment. A transverse shower shape analysis in the STAR Barrel Electromagnetic Calorimeter Shower Maximum Detector is used to discriminate between the direct photons and photons from the decays of high p$_T$ $\\pi^{0}$. The per-trigger away-side yield of direct $\\gamma$ is smaller than from ...

2008-01-01

254

Beam Test of a Prototype Detector Array for the PoGO Astronomical Hard X-Ray/Soft Gamma-Ray Polarimeter  

CERN Document Server

Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation ...

2005-01-01

255

The Italian survey as the basis of the national radon policy  

Energy Technology Data Exchange (ETDEWEB)

One of the most important goals of the Italian survey, initiated in 1989, was to promote ad hoc policies to reduce radon exposure of the population. In the survey a statistical representative sample of 5000 dwellings was chosen; two six-month measurements were made of the indoor radon concentration, in combination with one six-month measurement of gamma exposure. The results of the radon concentration measurements are reported here: they refer to 80% of the sample. The annual mean value was 81.5Bq.m{sup -3}, which is higher than that reported for other industrialised countries. (author).

1994-12-31

256

Radon measurements in dwellings using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.

1984-01-01

257

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

258

Measurement of the inclusive Z production cross section with the CMS detector  

CERN Document Server

First measurements of inclusive Z production cross sections in muon and electron decay channels at 7 TeV are presented for proton-proton collisions in the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). The comparison of the kinematic quantities as well as the studies of selection efficiencies demonstrate a good agreement between simulated events and current data. The measured inclusive cross section for Z($\\gamma^{*}$) production agrees with NNLO QCD cross section calculations and current parton distribution functions.

2010-01-01

259

Half-lives of the T{sub z}=1/2 series nuclei, {sup 81}Zr and {sup 85}Mo  

Energy Technology Data Exchange (ETDEWEB)

The nuclei {sup 81}Zr and {sup 85}Mo with T{sub z}=1/2 have been reinvestigated via their {beta}-delayed proton emissions with p-{gamma} coincidence measurement. The half-life of {sup 81}Zr has been measured to be 5.3{+-}0.5 s, which agrees with one of the two previous values. For {sup 85}Mo, the measured half-life is 3.2{+-}0.2 s, which revises the previous value. (orig.) With 3 figs., 12 refs.

1997-12-01

260

Half-lives of the T_z=1/2 series nuclei, "8"1Zr and "8"5Mo  

International Nuclear Information System (INIS)

The nuclei "8"1Zr and "8"5Mo with T_z=1/2 have been reinvestigated via their #beta#-delayed proton emissions with p-#gamma# coincidence measurement. The half-life of "8"1Zr has been measured to be 5.3#+-#0.5 s, which agrees with one of the two previous values. For "8"5Mo, the measured half-life is 3.2#+-#0.2 s, which revises the previous value. (orig.).

261

FFTF shield and gamma ray measurements  

Energy Technology Data Exchange (ETDEWEB)

Shield measurements and four cycles of operating experience have shown the design and construction of radiation shields for the Fast Flux Test Facility (FFTF) reactor and plant to be satisfactory. A number of minor shield deficiencies were found and corrected. Most of these were associated with interfaces between components, each of which was satisfactory by itself. Preliminary evaluation of the shield measurements indicates satisfactory agreement with design calculations. Operator doses to date have been quite small, especially when compared to light water reactor experience.

1984-08-01

265

Particle-Sizing System for Scanning Electron Microscope ...  

Science.gov (United States)

... THESIS PARTICLE-SIZING SYSTEM FOR SCANNING ELECTRON MICROSCOPE IMAGES OF SOLID-PROPELLANT COMBUSTION EXHAUST ...

1991-03-01

266

A bright field scanning transmission electron microscope (STEM ...  

Science.gov (United States)

A bright field scanning transmission electron microscope (STEM) micrograph showing a Wassonite grain in dark contrast. ...

267

Quality control and evaluation for environmental radiological baseline study of Guangdong Daya Bay nuclear power station  

International Nuclear Information System (INIS)

The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.

268

Minimal Neutrino Beta Beam for Large theta_13  

CERN Document Server

We discuss the minimum requirements for a neutrino beta beam if theta_13 is discovered by an upcoming reactor experiment, such as Double Chooz or Daya Bay. We require that both neutrino mass hierarchy and leptonic CP violation can be measured to competitive precisions with a single-baseline experiment in the entire remaining theta_13 range. We find that for very high isotope production rates, such as they might be possible using a production ring, a (B,Li) beta beam with a gamma as low as 60 could already be sufficient to perform all of these measurements. If only the often used nominal source luminosities can be achieved, for example, a (Ne,He) beta beam from Fermilab to a possibly existing water Cherenkov detector at Homestake with gamma \\sim 190-350 (depending on the Double Chooz best-fit) could outperform practically any other beam technology including wide-band beam and neutrino factory.

2008-01-01

269

Measurement of induced radioactivity in materials found around a neutron generator  

Science.gov (United States)

The induced radioactivity in the construction materials of a Cockcroft-- Walton type neutron generator was measured. Major activation products (/sup 24/ Na, /sup 28/Al, /sup 56/Mn, /sup 64/Cu, /sup 65/Ni, /sup 69m/Zn, /sup 88/Rb /sup 91/Sr /sup 101/Mo, /sup 187/W/ and resulting doses are tabulated. Results show that the highest gamma activities would be observed in the fluorescent bulbs, copper pipe, aluminum lattice rod, and the aluminum pipe clamp. Thermoluminescent dosimeter readings yield the highest doses for the copper pipe tee, copper pipe, and aluminum lattice rod. Results of measuremerts of the neutron and gamma dose profiles of the facility are shown. However the indication is clearly that the tritium target, compared to other components, is the major source of radiation both during and after shutdown. (UK)

1974-01-01

270

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.

1985-03-01

271

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

272

La{sup 3+} modified Al{sub 2}O{sub 3} as a support for CeO{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

X-ray photoelectron spectroscopy measurements indicate that the Ce{sup 3+} like fraction in {gamma}-Al{sub 2}O{sub 3} supported CeO{sub 2} can be decreased by the incorporation of La{sup 3+}. If La{sup 3+} is incorporated into the {gamma}-Al{sub 2}O{sub 3} before CeO{sub 2} is added, a higher CeO{sub 2} dispersion and a greater range of reversible reducibility of the CeO{sub 2} may also be obtained. These changes offer potential for improvement in the oxygen storage capacity provided by CeO{sub 2} in three-way catalysts. The actual effect of La{sup 3+} incorporation on the activity and durability of a Pt catalyst is assessed by a combination of temperature programmed reduction and flow reactor measurements.

1993-12-31

273

FFTF reactor characterization program  

International Nuclear Information System (INIS)

Preparations are under way for the initial startup and testing of the Fast Flux Test Facility (FFTF). The FFTF Reactor Characterization Program is that part of the startup test plan that deals with the determination of the neutron, gamma ray and thermal hydraulic characteristics of the reactor. This program encompasses measurements and calculations of: neutron spectra, flux and fluence; gamma-ray spectra, dose and heating; fission rate distributions; capture rate distributions; other reaction rates of interest; fission product yields; and thermal hydraulic data. Measurements of these parameters will be made in the reactor core and reflectors, will extend vertically downward to the vicinity of the core support structure and upward to the top of the sodium pool, and will extend radially outward to include in-vessel fuel storage locations and the cavity between the reactor vessel and the concrete wall.

274

Signatures of extra dimensions at e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The authors study the processes {gamma}e {r{underscore}arrow} {gamma}e and {gamma}{gamma} {r{underscore}arrow} {gamma}{gamma}, in the context of the proposal for Weak Scale Quantum Gravity (WSQG) with large extra dimensions. With an ultraviolet cutoff M{sub S} {approximately} 1 TeV for the effective gravity theory, the cross sections obtained for these processes at the Next Linear Collider (NLC), with the e{gamma} an {gamma}{gamma} options, deviate from the predictions of the Standard Model significantly. The results suggest that, for typical proposed NLC energies and luminosities, the predictions of WSQG can be tested in the range 1 TeV {approx{underscore}lt} M{sub S} {approx{underscore}lt} 10 TeV, making e{gamma} an {gamma}{gamma} colliders important tools for probing WSQG.

2000-01-26

275

Range-resolved gas concentration measurements using tunable semiconductor lasers  

British Library Electronic Table of Contents (United Kingdom)

A method for range-resolved gas sensing using path-integrated optical systems is presented. The method involves dividing an absorption path into several measurement segments and extracting the gas concentration in each segment from two path-integrated measurements. We implemented the method with tunable lasers (a 1389-nm VCSEL and a 10.9-?m pulsed quantum cascade laser) and a group of retro reflectors (RRs) distributed along absorption paths. Using a rotating mirror with the VCSEL configuration, we could scan a group of seven tape RRs spaced by 10?cm in ??9?ms to extract an H2O concentration profile. Reduced H2O concentrations were recorded in the segments purged with dry air. Hollow corner cube RRs were used in the quantum cascade laser configuration at distances up to 1.1?km from the las...

2008-01-01

276

Laser beam apparatus and method for analyzing solar cells  

Energy Technology Data Exchange (ETDEWEB)

A laser beam apparatus and method for analyzing, inter alia, the current versus voltage curve at the point of illumination on a solar cell and the open circuit voltage of a solar cell. The apparatus incorporates a lock-in amplifier, and a laser beam light chopper which permits the measurement of the AC current of the solar cell at an applied DC voltage at the position on the solar cell where the cell is illuminated and a feedback scheme which permits the direct scanning measurements of the open circuit voltage. The accuracy of the measurement is a function of the intensity and wavelength of the laser light with respect to the intensity and wavelength distribution of sunlight and the percentage the dark current is at the open circuit voltage to the short circuit current of the solar cell.

1980-01-01

277

Experimental investigation and modelling of heat capacity, heat of fusion and melting interval of rocks  

Energy Technology Data Exchange (ETDEWEB)

The heat capacity and heat of fusion were measured for a number of minerals using differential scanning calorimetry (DSC). The DSC measurements showed that the heat of fusion for the minerals is very low compared to the heat of fusion for pure crystalline phases reported elsewhere. A model for the melting behaviour of mineral materials in terms of melting interval, heat capacities and heat of fusion has been developed. The only model input is the chemical composition of the mineral material. The model was developed to be implemented in a detailed model of a cupola furnace, thus the focus for the development was not only precision but also to obtain a model that was continuous and differentiable. The model is based on several different submodels that each covers a part of the heating and melting of rocks. Each submodel is based on large amounts of empirical data. Comparison of the model and the DSC ...

2003-11-28

278

The Galactic Center Region Gamma Ray Excess from A Supersymmetric Leptophilic Higgs Model  

CERN Document Server

In a recent paper by Hooper and Goodenough, data from the Fermi Gamma Ray Telescope was analyzed and an excess of gamma rays was found in the emission spectrum from the Galactic Center Region. Hooper and Goodenough show that the excess can be well explained by 7-10 GeV annihilating dark matter with a power law density profile if the dark matter annihilates predominantly to tau pairs. In this paper we present such a dark matter model by extending the MSSM to include four Higgs doublets and one scalar singlet. A Z2 symmetry is imposed that enforces a Yukawa structure so that the up quarks, down quarks, and leptons each receive mass from a distinct doublet. This leads to an enhanced coupling of scalars to leptons and allows the model to naturally achieve the required phenomenology in order to explain the gamma ray excess. Our model yields the correct dark matter thermal relic density and avoids collider bounds from ...

2011-01-01

279

T=(5/2) "2"7Na from "1"4C+"1"4C, and the N=16 shell gap  

International Nuclear Information System (INIS)

For the first time a comprehensive level and decay scheme has been obtained for a T=(5/2) nucleus in the s-d shell ("2"7Na) by using a radioactive beam and target. Particle-#gamma# and p-#gamma#-#gamma# coincidences were measured following the "1"4C("1"4C,p#gamma#)"2"7Na reaction at E_l_a_b=22 MeV. The results do not support an inversion of the 2s_1_/_2 and 1d_5_/_2 orbitals, as previously proposed for T_z#>=#3, but they do suggest an increased N=16 gap between the 2s_1_/_2 and 1d_3_/_2 orbitals due to the neutron excess. A consistent interpretation of the level scheme in terms of the s-d shell model using the USD Hamiltonian is possible below 4 MeV, but differences increase at higher excitation energies. Another interpretation is that the influences of both the p_1_/_2 and f_7_/_2 intruder orbitals increase simultaneously with increasing T, an effect not included in the USD Hamiltonian.

2002-05-01

280

Spectroscopy of "8"8Sr with the "8"7Sr(n,#gamma#) and "8"7Sr(d,p) reactions  

International Nuclear Information System (INIS)

The #gamma#-ray spectrum emitted after thermal neutron capture in "8"7Sr was studied at the ILL high flux reactor with pair- and intrinsic Ge-spectrometers. 661 transitions were assigned to the reaction "8"7Sr(n,#gamma#)"8"8Sr and 205 of them were placed into a "8"8Sr level scheme of 47 levels. This represents 88% of the observed intensity. The level energies were determined with a precision of better than 22 ppm; the neutron binding energy was determined as 11 112.69 (22) keV. To aid the analysis high resolution particle spectra of the reaction "8"7Sr(d,p)"8"8Sr were measured at 20 MeV deuteron energy with the Munich Q3D spectrometer. 85 states were observed with this reaction. The data helped to establish newly found levels and to differentiate between primary and secondary transitions in the (n,#gamma#) data. The observed level densities and primary transition strengths are compared with statistical ...

281

Radiological assessment of terrestrial environment of facilities of G.I.P. CYCERON from Caen - year 2003; Bilan radiologique de l'environnement terrestre des installations du GIP CYCERON de Caen - annee 2003  

Energy Technology Data Exchange (ETDEWEB)

Concerning the gamma emitters, the only analysis on soils put in evidence the presence of cesium-137 ({sup 137}Cs), that does not come from the cyclotron functioning but from past man action as the Chernobylsk accident and the nuclear weapon tests in atmosphere. Independently of the functioning of the installation, we observe an increase of the ambient gamma radiation only near radioactive waste storage. It results of the storage of the former cyclotron elements. The induced increase is moderated because at 5 meters the values do not exceed the background noise. In relation with the functioning of the installation an increase of the ambient gamma radiation is noticed. Two causes are to considered: the release of radionuclides in atmosphere with gaseous effluents and the radiance of radiation sources inside the building. After the stopping of the installation (48 h at least), no increase of gamma ...

2004-07-01

282

Radiation damage and recovery in the light emittance efficiency and the attenuation length of barium fluoride scintillator  

International Nuclear Information System (INIS)

Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight ...

283

Diffuse $\\gamma$-rays and $\\bar{p}$ flux from dark matter annihilation -- a model for consistent results with EGRET and cosmic ray data  

CERN Document Server

In this work we develop a new propagation model for the Galactic cosmic rays based on the GALPROP code, including contributions from dark matter annihilation. The model predicts compatible Galactic diffuse $\\gamma$ ray spectra with EGRET data in all sky regions. It also gives consistent results of the diffuse $\\gamma$ ray longitude and latitude distributions. Further the results for B/C, $^{10}$Be/$^9$Be, proton, electron and antiproton spectra are also consistent with cosmic ray measurements. In the model we have taken a universal proton spectrum throughout the Galaxy without introducing large fluctuation for the proton energy loss is negligible. The dark matter annihilation signals are `boosted' after taking the contribution from subhalos into account. Another interesting feature of the model is that it gives better description of the diffuse $\\gamma$ rays when taking the source distribution ...

2007-01-01

284

The result of Alanine/ESR dosimetry at Wolsung unit 1  

International Nuclear Information System (INIS)

It needs accurate estimation of radiation level for verifying machinery and cable in Nuclear Power Plant. Therefore, in this study, we used ESR(Electron Spin Resonance) system for estimate dose of Alanine dosimeter. Alanine/ESR dosimetry, already known as a dosimetric method in medical and industrial field, was applied to estimate dose quantity at cable locations within a nuclear power plant as a part of equipment qualification program. Alanine/ESR dosimetry of absorbed dose range is 1 - 100 KGy. The alanine dosimeter is not significantly affected by temperature and fading is limited to 1% per year. The alanine dosimeters were fixed on the targeted cable or nearest position to measure dose quantity to get accurate value. Alanine dosimeters were scanned by commercially used two different ESR systems, e-scan and EMX series for alanine dosimeters. To estimate more accurate dose, two environmental correction factors, ...

2008-10-01

285

Scintiscanning with aerosols of "9"9Tc"m DTPA in the diagnostic strategy for pneumocystosis in aids patients  

International Nuclear Information System (INIS)

Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of lymphocytic alveolitis. An examination with normal ...

1988-08-15

286

Optimal alignment of mirror based pentaprisms for scanning deflectometric devices  

Science.gov (United States)

In the recent work [Proc. of SPIE 7801, 7801-2/1-12 (2010), Opt. Eng. 50(5) (2011), in press], we have reported on improvement of the Developmental Long Trace Profiler (DLTP), a slope measuring profiler available at the Advanced Light Source Optical Metrology Laboratory, achieved by replacing the bulk pentaprism with a mirror based pentaprism (MBPP). An original experimental procedure for optimal mutual alignment of the MBPP mirrors has been suggested and verified with numerical ray tracing simulations. It has been experimentally shown that the optimally aligned MBPP allows the elimination of systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of the bulk pentaprism. In the present article, we provide the analytical derivation and verification of easily executed optimal alignment algorithms for two different designs of mirror based pentaprisms. We also provide an analytical description for the mechanism for reduction ...

2011-03-04

287

Monte-Carlo simulations of 2-MeV #alpha#-particle channeling in Si_1_-_xSn_x alloy  

International Nuclear Information System (INIS)

Monte-Carlo simulations of 2-MeV #alpha#-particle channeling in Si_1_-_xSn_x alloys with 0#<=#x#<=#1 have been performed. The simulations are compared with measured channeling-angular scans for strained Si_0_._9_5Sn_0_._0_5 layers grown by molecular beam epitaxy (MBE). Agreement between simulated and measured angular scans can only be achieved if we assume a deviation of the crystal structure from the ideal one. This deviation can be attributed to a mosaic structure in the films and to an atomic-scale distortion of the crystal lattice due to an expected difference in the bond lengths between the Si-Si, Si-Sn and Sn-Sn atoms (such a difference in bond lengths has been observed in the epitaxial Si_1_-_xGe_x system). The contributions from both of these imperfections are estimated and discussed.

2000-04-01

288

Combined Scanning Electron Microscope and Micro-InfraRed measurements on Interplanetary Dust Particles  

CERN Document Server

Laboratory characterization of Interplanetary Dust Particles (IDPs) collected in the lower stratosphere represents a concrete analysis of cosmic dust properties which played a fundamental role in the origin and evolution of Solar System. The IDPs were characterized by Field Emission Scanning Electron Microscope (FESEM) analyses and by InfraRed (IR) micro-spectroscopy. We present the FESEM images of six IDPs: three smooth grains, two porous and one a compact sphere. We also show the results of micro-IR transmission measurements on four IDPs that allowed us to identify their spectral class according to the criteria defined by Sandford and Walker. Only three of the analyzed particles show IR transmission spectra with a dominant "silicate absorption feature" so that they could be assigned to the three IR spectral classes: one has been classified as "amorphous olivine", one appears to be a mixture of "olivines" and "pyroxenes" and one belongs to the ...

2007-01-01

289

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. ...

290

The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters  

Energy Technology Data Exchange (ETDEWEB)

The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not been reported previously, whereas in the case of SEI glass, there exists a modest body of previous work on ...

1990-01-01

291

The thermal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent glass dosimeters  

International Nuclear Information System (INIS)

The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not been reported previously, whereas in the case of SEI glass, there exists a modest body of previous work on ...

292

Particle emission from low energy nuclear reactions in solids. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons or deuterons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Deuteron irradiation of TiD{sub 2} produced these observations: copious {approx}2.5 MeV neutrons and {approx}3 MeV protons from direct D-D reactions; gamma rays from p,{gamma} and n,{gamma} reactions; {approx}14 MeV protons from the secondary d({sup 3}He, p){alpha} reaction; and a signal between {approx}6-12 MeV that Kasagi et al. has tentatively identified as protons from the fusion of three deuterium nuclei. However, this signal has in it a strong interference signal from either neutrons or gamma rays that directly deposit energy in the detector. This interference spectra was measured by placing a thick absorber in front of the detector that stops up to 20 MeV protons, but not ...

2000-07-01

293

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons  

Energy Technology Data Exchange (ETDEWEB)

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical ...

2010-05-01

294

Quick separation of fission product molybdenum and gamma-rays of Mo-102  

International Nuclear Information System (INIS)

... electrophoresis fission products gamma radiation gamma spectra half-life

295

Probing of the Higgs-fermion coupling at. gamma. gamma. -colliders  

Energy Technology Data Exchange (ETDEWEB)

Three possibilities to observe the Higgs-top interaction at future {gamma}{gamma}-colliders are discussed: (a) associated Higss production via the {gamma}{gamma}{yields}tanti tH reaction, (b) Higgs obliged radiative correction to the {gamma}{gamma}{yields}tanti t channel, (c) Higgs resonance production via {gamma}{gamma}{yields}H{yields}ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at {gamma}{gamma}-colliders. (orig.).

1992-11-01

296

Probing of the Higgs-fermion coupling at #gamma##gamma#-colliders  

International Nuclear Information System (INIS)

Three possibilities to observe the Higgs-top interaction at future #gamma##gamma#-colliders are discussed: a) associated Higss production via the #gamma##gamma##->#tanti tH reaction, b) Higgs obliged radiative correction to the #gamma##gamma##->#tanti t channel, c) Higgs resonance production via #gamma##gamma##->#H#->#ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at #gamma##gamma#-colliders. (orig.).

297

Investigation of W"1"7"7 decay scheme by #gamma##gamma#-coincidence method  

International Nuclear Information System (INIS)

... coincidence spectrometry decay excited states gamma spectra half-life

1973-01-29

298

Thermodynamics of potassium diclofenac salt aqueous solutions at various temperatures  

British Library Electronic Table of Contents (United Kingdom)

Solution and dilution enthalpies of aqueous solutions of potassium diclofenac salt (K_DC) were measured by an isoperibolic calorimeter at 298.15 and 318.5?K. Heat capacities of the solutions with concentrations 0.002?0.09?mol?kg?1 were obtained at the temperature interval of 288.15?318.15?K using a scanning adiabatic microcalorimeter. The virial coefficients were derived from Pitzer?s model, and the excess thermodynamic functions of both the solvent and the solute of the solution were calculated. The concentration and temperature dependencies of thermodynamic characteristics of the solution were analyzed and discussed.

2011-01-01

299

Precipitation, phase transformation, and enhanced diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

This paper describes Z-contrast scanning transmission electron microscopy used to study the connection between dopant precipitation and phase transformation in high dose In"+ and Sb"+ implanted Si. In the case of In, the observations confirm a heterogeneous nucleation model. Images of the precursor precipitates give the first measurement of the diffusion coefficient in amorphous Si, with an enhancement of 10"7 over tracer crystalline values. With Sb"+ implants enhanced homogeneous nucleation is observed. The connection between these results and the transient enhanced diffusion observed in crystallized Si is discussed.

300

Pitting corrosion of nickel base alloys in halide media  

International Nuclear Information System (INIS)

A computerized corrosion measuring system (EG and G model 350 A) was used to study the influence of Cr, Mo, Ti, Nb and W on the pitting corrosion of nickel base alloys in 3% NaCl at 90"0C. The electrochemical parameters under investigation are the corrosion potential E_c_o_r_r, pitting potential E_p and protection potential E_p_p. The corrosion behaviour of nickel base alloys were studied by using pitting scan and potentiostatic techniques. Values of corrosion potential, pitting potential and protection potential were used for a ranking of alloys for corrosion resistance.

1988-03-06

301

Nanocrystallization of the amorphous Fe_1_4Ni_4_0Zr_7B_1_2 alloys studied by the Moessbauer spectroscopy  

International Nuclear Information System (INIS)

Formation of the soft magnetic nanostructure in amorphous Fe_1_4Ni_4_0Zr_7B_1_2 alloy due to heat treatment is studied by the Moessbauer, differential scanning calorimetry, and X-ray diffraction techniques. Annealing at temperatures 520-580 "oC leads to the formation of extremely soft nanocrystalline alloy as revealed by the rf-Moessbauer measurements. The superparamagnetic behaviour was observed for the alloy annealed at 620-640 "oC. At higher annealing temperatures good soft magnetic properties deteriorate. (author)

2001-09-23

302

Influence of microalloying on the corrosion resistance of steel in saturated calcium hydroxide  

International Nuclear Information System (INIS)

The influence of microalloying vanadium or titanium on improving the corrosion resistance of mild steel in saturated calcium hydroxide solution was investigated. Potential-time, potentiodynamic polarization, and impedance measurement techniques were employed. The corrosion products have been examined by infrared and X-ray diffraction analysis and by scanning electron microscopy. It has been shown that the grain refining, due to microalloying, plays an important role in enhancing the corrosion resistance of steel. Scales of calcite and iron oxides on top of a protective oxide are formed on the investigated steels.

303

An integrated approach to the modelling of hydrogen assisted failure in 316L steel  

International Nuclear Information System (INIS)

An integrated approach to the modelling of hydrogen assisted failure in 316L steel is presented. The approach includes experimental, fractographic, numerical and theoretical analysis of the phenomenon. The physical adequacy of the mechanical models of hydrogen embrittlement (notch extension model and notch cracking model) is discussed by comparing the virtual damage depth (theoretical) predicted by the models with the embrittled zone (microphysical) measured in the fractographic analysis by scanning electron microscopy. In addition, a numerical modelling of hydrogen diffusion is performed, concluding that bulk diffusion is not important in hydrogen embrittlement of 316L steel, so that hydrogen transport accelerated by the microdamage itself should be taken into account. (orig.)

1998-09-01

304

A correlation between electrochemical parameters and stress corrosion cracking of alloy 600 in high temperature caustic solution  

International Nuclear Information System (INIS)

The properties of the passive films formed on Alloy 600 at different applied potentials in 10% NaOH solution at 315 .deg. C was studied using in situ AC impedance and polarization measurements. The results were correlated with the stress corrosion cracking (SCC) behavior obtained from the C-ring tests in the same conditions. The change of the semiconductive property and the peak of relaxation time were observed at 0.2 V where the SCC rate showed a maximum. These results were also consistent with the prediction parameter for SCC obtained from fast and slow polarization scans.

2001-10-01

305

A Virtual Young's Double Slit Experiment for Hard X-ray Photons  

CERN Document Server

We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.

2009-01-01

306

Proceedings of the first meeting on e{gamma}/{gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The first meeting on e{gamma}/{gamma}{gamma} colliders was held on September 28 and 29, 1993, at the National Laboratory for High Energy Physics. After general remarks were delivered, lectures were given on QED in intense laser field, photon linear collider, laser focusing, luminosity distribution in the e{gamma}/{gamma}{gamma} colliders, QCD correction for {gamma}{gamma}{yields}H, radiation correction for e{gamma}/{nu}W process, SUSY particle production at the e{gamma} and {gamma} gamma colliders, formation of e{sup *} in e{gamma} collision, and general remarks on the theory. Discussion was carried out on `Where are we going from here?` In this book, the gists of the lectures are collected. (K.I.).

1994-01-01

307

Failed nuclear fuel rod analysis by gamma computed tomography  

International Nuclear Information System (INIS)

Fuel rod failures produce a release of fission products into primary coolant system. Since nuclear power plants have licensing limits for the release of volatile fission products to the environment (off-gas limits) detailed monitoring of the development of clad failure is necessary. In case of fuel rod failure a release of fission products into the primary coolant system arises. Fission gases accumulated in the free volume of a fuel rod escape through the clad defect. Water entering the fuel rod reacts with fission products, forming volatile chemical compounds. These may escape in a similar manner into the fission gases. Other compounds may dissolve and may be carried outside the fuel rod as dissolved species. Consequently, the distribution of these fission products, in the cross section of the fuel rod, is modified. An implementation of the maximum entropy gamma computed tomography technique is used to obtain such distributions in the area of the fuel rod ...

308

Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array  

Science.gov (United States)

The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a ...

2009-03-10

309

An aerial radiological survey of the Portsmouth Gaseous Diffusion Plant and surrounding area  

International Nuclear Information System (INIS)

An aerial radiological survey was conducted from August 10-16, 1993, over a 78-square-kilometer (30-square-mile) area of the Portsmouth Gaseous Diffusion Plant and surrounding area located near Portsmouth, Ohio. The survey was performed at a nominal altitude of 46 meters (150 feet) with a line spacing of 76 meters (250 feet). A contour map of the terrestrial gamma exposure rate extrapolated to 1 meter above ground level was prepared and overlaid on a set of United States Geological Survey topographic maps of the area and an aerial photograph of the plant. The terrestrial gamma exposure rates varied from about 7 to 14 microroentgens per hour at 1 meter above the ground. Protactinium-234m was observed at six sites within the boundaries of the plant. At a seventh site, only uranium-235 was observed. No other man-made, gamma ray-emitting radioactive material was present in a detectable quantity, either on or off the plant ...

2005-05-01

310

The Preliminary GAMMA Code Thermal hydraulic Analysis for the Steady State of HTR-10 Initial Core  

Energy Technology Data Exchange (ETDEWEB)

This report describes the preliminary thermalhydraulic analysis of HTR-10 steady state full power initial core to provide a benchmark calculation of VHTGR(Very High-Temperature Gas-Cooled Reactors) safety analysis code of GAMMA(GAs Multicomponent Mixture Analysis). The input data of GAMMA code are produced for the models of fluid block, wall block, radiation heat transfer and each component material properties in HTR-10 reactor. The temperature and flow distributions of HTR-10 steady state 10 MW{sub th} full power initial core are calculated by GAMMA code with boundary conditions of total reactor inlet flow rate of 4.32 kg/s, inlet temperature of 250 .deg. C, inlet pressure of 3 MPa, outlet pressure of 2.992 MPa and the fixed temperature at RCCS water cooling tube of 50 .deg C. The calculation results are compared with the measured solid material temperatures at 22 fixed instrumentation positions in ...

2006-07-15

311

Development of a Computer Program for the Integrated Control of the Fuel Homogeneity Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The computer program is developed based on Visual C++, which is equipped with a user-friendly interface of the input/output(I/O) and a display function for the measuring conditions. This program consists of three parts which are the port communication, PLC(Programmable Logic Controller) and the MCA(Multi Channel Analyzer) control parts. The communication type between the CPU of the PLC module box and the computer is selected as be the Rs-232 asynchronous type and the thread method is adapted in the development of the first part of the program. The PLC-related program has been developed so that the data communication between the PLC CPU and the computer could be harmonized with the unique commands which have already been defined in the PLC. The measuring space and time intervals, the start and end ROI(region of interest) values, and the allowable error limitation are input at each measurement in this program. Finally the ...

2005-11-15

312

Width of the 1. 836-MeV level in /sup 88/Sr  

Science.gov (United States)

Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2/sup +//sub 1/ level in /sup 88/Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.

1977-06-01

313

The triaxial motion in Mo isotopes  

Energy Technology Data Exchange (ETDEWEB)

The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of [sup 87]Mo are studied in detail and explained by the evolution of the [gamma]-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N [>=] 47 for the spherical shape of the Mo isotopes. (orig.)

1993-11-22

314

The triaxial motion in Mo isotopes  

International Nuclear Information System (INIS)

The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of "8"7Mo are studied in detail and explained by the evolution of the #gamma#-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N #>=# 47 for the spherical shape of the Mo isotopes. (orig.).

315

Tests for mutagencity of free radicals formed in irradiated sugars and amino acids  

International Nuclear Information System (INIS)

Radicals formed in gamma-irradiated crystals of galactose and glycine were found, upon dissolution, to cause mutagenesis of Salmonella typhimurium strains TA-98 and TA-100. Although the reproducibility of the results has not been adequately determined, they suggest the possibility of developing a test to measure the mutagenic-carcinogenic potential of radiation-induced free radicals with a microbial system.

1977-05-01

316

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

317

Radiation treatment of some poultry products  

International Nuclear Information System (INIS)

Practical procedures were developed for large-scale microbial decontamination of dry egg powder and gelatine with gamma radiation ("6"0Co). The formation and lifes of free organic radicals in these materials were examined by ESR measurements of powder samples. The concentration of these radicals was studied in dependence on the time of storage. Secondary oxidation of egg fats by air oxygen was investigated. Sensoric tests of irradiated gelatine, both in powder and hydrogel form, were performed. (author). 4 figs., 2 tabs., 2 refs.

1988-09-26

318

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

319

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

320

Investigation of Moessbauer radiation diffraction on Fe/sub 3/BO/sub 6/ monocrystal. Nuclear transition interference  

Energy Technology Data Exchange (ETDEWEB)

Energy spectra of the Bragg reflection of the Moessbauer ..gamma..-radiation from the /sup 57/Fe/sub 3/BO/sub 6/ weakly ferromagnetic monocrystal are studied. A strong effect of the interference transitions in iron nuclei, being in non-equivalent positions, on the spectra form is revealed. The measurement results are compared with theoretical calculations.

1984-05-25

321

In-beam conversion electron spectroscopy using the SACRED array  

International Nuclear Information System (INIS)

Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.

322

Evaluation of radiation resistance of cable connector material  

Energy Technology Data Exchange (ETDEWEB)

Radiation degradation of polycarbonate (PC) and polybutylene terephthalate (PBT) used as cable connector was evaluated using DSC, TGA, and mechanical properties. Glass transition temperature, melting temperature, 5% weight loss temperature, elongation at break, and tensile strength measurements were carried out for each of {gamma}-ray irradiated samples. In the results of those analyses, PC has radiation resistance better than PBT as a cable connector material.

2002-10-01

323

Changes in the profile structure of the sarcoplasmic reticulum membrane induced by phosphorylation of the Ca2+ ATPase enzyme in the presence of terbium: a time-resolved x-ray diffraction study.  

UK PubMed Central (United Kingdom)

The design of the time-resolved x-ray diffraction experiments reported in this and an accompanying paper was based on direct measurements of enzyme phosphorylation using [gamma-32P]ATP that were employed...Full Text Available

1994-05-01

324

Anomalous solvent extraction behavior of astatine  

International Nuclear Information System (INIS)

We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).

325

Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors  

Energy Technology Data Exchange (ETDEWEB)

A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.)

1993-10-01

326

Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors  

International Nuclear Information System (INIS)

A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.).

327

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

Energy Technology Data Exchange (ETDEWEB)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides {sup 226}Ra, {sup 228}Th and {sup 40}K. Radon concentrations were found to range from 1270 to 155000Bqm{sup -3} with an average of 33765Bqm{sup -3} and a median value of 12626Bqm{sup -3}. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm{sup -3} and 3.5Bqm{sup -3}, respectively. ...

2007-11-15

328

A campaign of discrete radon concentration measurements in soil of Niska Banja town, Serbia  

International Nuclear Information System (INIS)

The first radon soil gas survey in Serbia, using passive detectors (SSNTD, CR-39), was carried out in June 2005 at field sites in Niska Banja town. The aim of the survey was to identify risk zones characterised by high levels of this radioactive gas. Radon measurements were made at the depth of 50 cm, in the ground according to a systematic grid pattern. Furthermore, at all 48 measurement points, the surface gamma dose rates in the air was also measured at the same locations and soil samples were collected for gamma spectrometric analysis for the radionuclides "2"2"6Ra, "2"2"8Th and "4"0K. Radon concentrations were found to range from 1270 to 155000Bqm"-"3 with an average of 33765Bqm"-"3 and a median value of 12626Bqm"-"3. The geometrical mean value and geometrical standard deviation were calculated as 16160Bqm"-"3 and 3.5Bqm"-"3, respectively. Gamma dose rate ...

2007-11-01

329

The ''nuclear car wash'': a scanner to detect illicit special nuclear material in cargo containers  

International Nuclear Information System (INIS)

There is an urgent need to improve the reliability of screening cargo containers for illicit nuclear material that may be hidden there for terrorist purposes. A screening system is described for detection of fissionable material hidden in maritime cargo containers. The system makes use of a low intensity neutron beam for producing fission; and the detection of the abundant high-energy #gamma# rays emitted in the #beta#-decay of short-lived fission products and #beta#-delayed neutrons. The abundance of the delayed #gamma# rays is almost an order of magnitude larger than that of the delayed neutrons normally used to detect fission and they are emitted on about the same time scale as the delayed neutrons, i.e., #approx#1 min. The energy and temporal distributions of the delayed #gamma# rays provide a unique signature of fission. Because of their high energy, these delayed #gamma# rays penetrate loW--Z ...

2004-01-28

330

GaP Project: #gamma#p, #gamma#e, #gamma##gamma# colliders physical programs and CompHEP computer system  

International Nuclear Information System (INIS)

The Gamma Physics (GaP) program of physical phenomena investigation is proposed on #gamma#p, #gamma#e and #gamma##gamma# colliders at TeV energies. The program contains specialized software (CompHEP system) created for automation of particle interaction processes calculations in the framework of various gauge models. Preliminary physical results are presented (heavy quark production, W, Z production, supersymmetry etc.), and further software development is suggested. (R.P.) 22 refs., 8 figs., 4 tabs.

331

Solution of the orthopositronium lifetime puzzle  

CERN Document Server

The intrinsic decay rate of orthopositronium formed in SiO/sub 2/ powder is measured using the direct 2 gamma correction method such that the time dependence of the pick-off annihilation rate is precisely determined. The decay rate of orthopositronium is found to be 7.0396+or-0.0012(stat.)+or-0.0011(sys.)/ mu s/sup -1/, which is consistent with our previous measurements with about twice the accuracy. Results agree well with the O( alpha /sup 2/) QED prediction, and also with a result reported very recently using nanoporous film.

2004-01-01

332

Moessbauer diffraction measurements on polycrystalline bcc iron  

Energy Technology Data Exchange (ETDEWEB)

In the early days of Moessbauer spectroscopy, it was demonstrated that coherent scattering of photons emitted by a Moessbauer source can be observed. In spite of the fact that scattering experiments could give information not accessible by the absorption method, they are not widely used. The reasons for this are, on the one hand, experimental difficulties, and on the other hand, the form of the samples, which should be large single crystals in most cases. In this work, we present a Moessbauer diffraction measurement on polycrystalline bcc iron where these problems have been overcome. We demonstrate that using the kinematical theory of gamma-ray diffraction, useful information on the relative orientation of the crystallographic axis to the hyperfine field directions can be subtracted. (orig.)

1994-11-01

333

MCNP-DSP calculations of the {sup 252}Cf-source-driven noise analysis measurements of highly enriched uranium metal cylinders  

Energy Technology Data Exchange (ETDEWEB)

This paper presents calculations of the {sup 252}Cf-source-driven noise analysis measurements for subcritical highly enriched uranium metal cylinders using the Monte Carlo code MCNP-DSP. This code directly calculates the noise analysis data from the {sup 252}Cf- source-driven noise analysis method for both neutron and gamma ray detectors. Direct calculation of experimental observables by the Monte Carlo method allows for the benchmarking of the calculational model and the cross sections and for determining the bias in the calculation.

1995-07-01

334

Effect of substrate on the results of measuring coating thickness according to radiation scattered by substrate  

International Nuclear Information System (INIS)

The effect of a substrate on the results of measuring tantalum coating thickness in two-layer compositions according to gamma radiation scattered by the substrate is studied. It is shown that by means of an albedo-radiometer realizing the physical model absorber-scatterer one can determine the thickness (application uniformity) of tantalum coatings up to 150-300 #mu#m depending on the substrate material (plexiglas, aluminium, iron, copper). In case of testing coatings on substrates of alloys and high-alloy steels in order to ensure high accuracy of measrurement it is expedient with the above albedo-radiometer to determine the value of the backscattered radiation flux for the substrate before coating application.

335

The neutron capture cross sections of {sup 237}Np(n,{gamma}) and {sup 240}Pu(n,{gamma}) and its relevance in the transmutation of nuclear waste  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture cross sections of actinides are of great relevance for the Transmutation of Nuclear Waste in Accelerator Driven Systems (ADS) and Generation-IV reactors. The neutron capture cross sections of {sup 237}Np and {sup 240}Pu in the range of 1 eV to 2 keV were measured at the n-TOF facility with a Total Absorption Calorimeter. The data have been analyzed with the SAMMY code. The corresponding covariance matrices have been generated. The final cross sections are presented and compared to the previously existing ones.The n-TOF {sup 237}Np {sigma}(n,{gamma}) is in agreement with the evaluated data files below 300 eV and its is lower by 10 to 15% up to 2 keV. This discrepancy with the evaluated data files is also observed in the capture cross section derived from the transmission measurements of Gressier et al. In the case of the {sup 240}Pu {sigma}(n,{gamma}), the n-TOF ...

2008-07-01

336

A spatial sensitivity analysis technique for neutron and gamma-ray measurements  

International Nuclear Information System (INIS)

In the fields of medical imaging, geophysical well logging, and industrial radiography, it is often of interest to characterize the spatially distributed sensitivities of neutron and gamma-ray measurement devices to the physical properties of the materials being examined. For instance, one may wish to know how the count rate in a detector varies in response to small changes in the local density of the irradiated object as a function of position. Experimental determination of such sensitivity functions is often impractical. Consequently, we have developed a general three-dimensional Monte Carlo numerical technique that allows us to directly compute the differential sensitivity of an arbitrary integral response parameter, such as a time- or energy-discriminated count rate, with respect to the spatial distribution of macroscopic cross sections and sources in the irradiated medium. Sensitivities to object density, porosity, etc., can easily be ...

1992-09-08

337

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

Energy Technology Data Exchange (ETDEWEB)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of {sup 226}Ra and {sup 232}Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

1999-07-01

338

Radon Levels and Related Doses in a Prototype Jamaican House Constructed with Bauxite Waste Blocks  

International Nuclear Information System (INIS)

Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of "2"2"6Ra and "2"3"2Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)

339

Measurement of radon daughter product burden by TLD dosemeters  

International Nuclear Information System (INIS)

A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.

340

Concentrations of radon and decay products in various underground mines in western Turkey and total effective dose equivalents  

Energy Technology Data Exchange (ETDEWEB)

Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.

1998-01-01

341

Application of low-dose radiation protocols in survey CT scans  

International Nuclear Information System (INIS)

Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were ...

2009-08-01

342

Water-repellency and antibacterial activities of plasma-treated cleavable silicone surfactants on nylon fabrics  

British Library Electronic Table of Contents (United Kingdom)

In this paper we describe how cleavable surfactants decompose into water-insoluble silanols and two water-soluble products when subjected to vacuum plasma treatment. We used Raman spectroscopic analysis to confirm these structural changes, and we performed contact angle measurements and employed scanning electron microscopy to observe the surface morphologies of these compounds. Our contact angle measurements confirm that the products had degraded on nylon fabrics during argon gas plasma treatment. All of the PEG-silicone polyesters displayed excellent water-repellency; PEG6000-silicone exhibited the largest contact angle (130?) and, hence, the greatest water-repellency. Our results indicate that the silanols that form upon plasma treatment may be useful in coatings applications. We also f...

2006-01-01

343

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.

344

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

345

Investigating the effect of an arterial hypertension drug on the structural properties of plasma protein  

British Library Electronic Table of Contents (United Kingdom)

Propanolol is a betablocker drug used in the treatment of arterial hypertension related diseases. In order to achieve an optimal performance of this drug it is important to consider the possible interactions of propanolol with plasma proteins. In this work, we have used several experimental techniques to characterise the effect of addition of the betablocker propanolol on the properties of bovine plasma fibrinogen (FB). Differential scanning calorimeter (DSC), circular dichroism (CD), dynamic light scattering (DLS), surface tension techniques and atomic force microscopy (AFM) measurements have been combined to carry out a detailed physicochemical and surface characterization of the mixed system. As a result, DSC measurements show that propranolol can play two opposite roles, either acting ...

2011-01-01

346

Electrochemical deposition of indium sulfide thin films using two-step pulse biasing  

British Library Electronic Table of Contents (United Kingdom)

Indium sulfide thin films were deposited onto indium-tin-oxide coated glass substrate by electrochemical deposition from an aqueous solution containing In2 (SO4) 3 and Na2S2O3. The deposition conditions were optimized on the basis of data obtained by scanning electron microscope, Auger electron spectroscopy and optical transmission measurements. Furthermore, the photosensitivity of the films was observed by means of photoelectrochemical measurements, which confirmed that the indium sulfide showed n-type conduction. The X-ray diffraction and Raman studies revealed that the as-grown films were amorphous or nanocrystalline in nature and became polycrystalline In2S3 after annealing.

2008-01-01

347

Circumsolar radiation telescope  

Energy Technology Data Exchange (ETDEWEB)

A circumsolar telescope for determining the flux of energy from the sun and from the circumsolar region as a function of angle, wavelength, and atmospheric conditions is presented. The telescope system consists of a specially designed scanning telescope, an electronic control and recording system and some auxiliary equipment. The detector is a pyroelectric crystal, a type of thermal detector, thus the fundamental measurement is relatively wavelength insensitive. The telescope is designed to provide data for all weather conditions during which a concentrating solar energy system would be operating. Analyses show that for a clear blue sky, the amount of radiation coming directly from the sun, while for a sky with thin clouds or haze, the circumsolar radiation is some 25% of the direct solar radiation. Under such conditions a measure of the circumsolar radiation is necessary for an accurate prediction of the performance of a ...

1980-01-01

348

ESR/Alanine dosimetry on Wolsung Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...

2007-07-01

349

ESR/Alanine dosimetry on Wolsung Unit 1  

International Nuclear Information System (INIS)

Alanine/EPR Dosimetry system is classified as a reference-standard dosimeter which used to calibrate radiation environments and to calibrate routine dosimeters in absorbed dose range of 1 to 105 Gy. Characteristics of Alanine/EPR dosimetry system are better suitable than routinely used personnel dosimeters for the long term radiation measurement in harsh condition of Nuclear power plant : This system is not significantly affected by temperature and humidity and also has low fading rate. About 1 year ago, Alanine and Lithium compound dosimeters were installed at Wolsung unit 1 for the environment monitoring as a part of equipment qualification program. 35 positions which are most severe and representative cable positions were chosen for radiation and temperature monitoring. The recovered alanine dosimeter in the period of maintenance was measured by E-scan alanine analyzer system, Meanwhile measurement ...

2007-05-10

351

Principles of photon colliders  

Energy Technology Data Exchange (ETDEWEB)

Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).

1995-02-01

352

Composite vector leptoquarks in e"+e-, #gamma#e, and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study the signals for composite vector leptoquarks in e"+e- colliders (CERN e"+e- collider LEP II, Next Linear Collider, and CERN Linear Collider) through their effects on the production of jet pairs, as well as their single and pair productions. We also analyze their production in #gamma#e and #gamma##gamma# collisions.

353

Quantitative bone scintigraphy in patients with osteoporosis  

International Nuclear Information System (INIS)

Quantitative bone scans were evaluated in 16 patients with osteoporosis and in a control group of 7 healthy subjects. Along with a detailed biochemical analysis of calcium-phosphorus metabolism and standartized reongenographs, a quantitative dynamic bone scintigraphy was performed according to the method proposed by the authors. The bone-accumulating factor K_b was determined on the base of mathematical analysis of the graph reflecting activity changes in bone tissue unit during the investigation, the blood-elimination factor K_h and kidney-elimination factor K_k. In addition the accumulation index AI (in %) was calculated as a relation between the activity in bone tissue unit, registered in 20 min interval, and the activity in soft tissues for the same time. Whereas the static gamma camera scintigraphy, made 3-4 hrs after injecting of the osteotrope radiopharmaceuticals, showed no specific changes in the patients examined, the method proposed ...

354

Preservation of beech and spruce wood by allyl alcohol-based copolymers  

International Nuclear Information System (INIS)

Allyl alcohol (AA), acrylonitrile (AN), methyl methacrylate (MMA), monomers and monomer mixtures AA+AN, AA+MMA were used to conserve and consolidate Beech and Spruce. After impregnation, copolymerisation and polymerisation were accomplished by gamma irradiation. The fine structure of wood+polymer(copolymer) composites was investigated by Scanning Electron Microscopy (SEM). It was observed that copolymer obtained from AA+MMA monomer mixture showed the optimum compatibility. The compressional strength and Brinell Hardness Numbers determined for untreated and treated wood samples indicated that the mechanical strength of wood+copolymer composites was increased. It was found that the mechanical strength of the wood samples containing the AA+MMA copolymer was higher than the others. In the presence of P(AA/MMA), at highest conversion, the compressive strength perpendicular to the fibres in Beech and Spruce increased approximately 100 times. The ...

1999-06-01

355

Physico Mechanical Properties of Irradiated Waste Rubber Cement Mortar  

International Nuclear Information System (INIS)

In the present study a partial replacement of aggregate with two different ratios of waste rubber (5%, 10%) with the addition of a constant ratio of rice husk ash (RHA), 5% was carried out. The hardened cement mortar used the optimum water of consistency. The specimens were molded into 1 inch cubic moulds .The specimens were first cured for 24 hours, at 100% relative humidity and then cured under tap water for 3, 7 and 28 days followed by irradiation at different doses of gamma irradiation namely 5 and 10 kGy. The physico-chemical and mechanical properties such as compressive strength, total porosity and bulk density were studied for the three types of specimens. The results showed that the values of the compressive strength, bulk density and chemically combined water of the blended cement mortar paste (OPC-RHA) increase ,while blended cement mortar paste with 5% RHA and 5, 10% waste rubber decrease. The results were confirmed by scanning ...

356

Pharmacokinetic and dosimetric characteristics of some thallium isotopes  

International Nuclear Information System (INIS)

Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the dose from lead-201 and lead-203 may be ignored. Doses from thallium-199 preparation ...

357

Is there an enhancement of muons at sea level from transient events?  

CERN Document Server

In a recent study of a search for enhancements from the galactic center with muons at sea level using the TUPI muon telescope, we have found several ground level enhancements (GLEs) as very sharp peaks above the count rate background. This paper reports a consistent analysis of two GLEs observed in December 2003 and detected after an up-grade of the data acquisition system, which includes a noise filter and which allows us to verify that the GLEs are not mere background fluctuations. The main target of this study is a search for the origin of the GLEs. The results show that one of them has a strong correlation with a solar flare, while the other has an unknown origin, because there is neither a satellite report of a solar flare, nor prompt X-ray emission, and nor a excess of nuclei during the raster scan where the GLE was observed. Even so, two possibilities are analyzed: the solar flare hypothesis and the gamma ray burst (GRB) hypothesis. We ...

2004-01-01

358

Irradiation behavior of FBTR mixed carbide fuel at various burn-ups  

International Nuclear Information System (INIS)

The fast breeder test reactor at Kalpakkam has completed nearly 25 years of operation and is now operating at 18 MWt capacity with 46 fuel subassemblies (FSA) in the core consisting of 27 Mark-I (70% PuC + 30% UC), 13 Mark-II (55% PuC + 45% UC) and 6 MOX (44% PuO_2 + 56% UO_2) and one test PFBR FSA. Post Irradiation Examination (PIE) campaigns on FSAs at different burnup levels has provided valuable information about the irradiation behavior of the carbide fuel. This paper gives a summary of the irradiation performance of the carbide fuel evaluated through some of the investigations such as neutron radiography, x-radiography, gamma scanning, fission gas analysis and ceramography. Burnup of the carbide fuel could be enhanced from the initial design burnup limit of 50 GWd/t to 165 GWd/through systematic PIE. (author)

2010-10-01

359

IAEA RESEARCH CONTRACTS SECOND ANNUAL REPORT. Technical Reports Series No. 9  

Science.gov (United States)

Summaries are presented for those research contracts which expired between December 31, 1960 and December 31, 1981. Topics covered include: factors controlling distribution of fission products in biosphere, non-destructive methods of evaluating the U/sup 235/ and Pu content of irradiated fuel elements, studies of contamination in local marine resources, tracer studies of anemia, non-destructive analysis of irradiated fuel elements using a flux integrating monitor, mechanism of proteolysis of I/sup 131/-labeled fibrinogen, radiosensitivity of spermatogonia of Drosophila melel elements by gamma scanning, uptake and loss of radioactive material by marine bacteria, factors which influence the movement of radioactive strontium from soils to plants, biological concentration of fission products in mollusks from water, decay scheme of Tl/sup 210/, calcium balance in metabolic bone disease, development of radioactive drugs ...

1962-01-01

360

Characterization of spent fuel approved testing material: ATM-106  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to date are described for Approved Testing Material (ATM)-106 spent fuel from Assembly BT03 of pressurized-water reactor Calvert Cliffs No. 1. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well- characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCWRM) program. ATM-106 consists of 20 full-length irradiated fuel rods with rod-average burnups of about 3700 GJ/kgM (43 MWd/kgM) and expected fission gas release of /approximately/10%. Characterization data include (1) as-fabricated fuel design, irradiation history, and subsequent storage and handling; (2) isotopic gamma scans; (3) fission gas analyses; (4) ceramography of the fuel and metallography of the cladding; (5) calculated nuclide ...

1988-10-01

361

Characterization of spent fuel approved testing material: ATM-103  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to date are described for Approved Testing Material (ATM)-103, which is spent fuel from Assembly D101 of pressurized-water reactor Calvert Cliffs, No. 1. This report is one in a series being written by the Materials Characterization Center (MCC) at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US nuclear waste repository program. ATM-103 consists of 176 full-length irradiated fuel rods with rod-average burnups of about 2600 GJ/kgM (30 MWd/kgM) and less than 1% fission gas release. Characterization data include 1) as-fabricated fuel design, irradiation history, and subsequent storage and handling; 2) isotopic gamma scans; 3) fission gas analyses; 4) ceramography of the fuel and metallography of the cladding; 5) special fuels studies involving analytical transmission electron microscopy ...

1988-04-01

362

Characterization of spent fuel approved testing material--ATM-104  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to date are described for Approved Testing Material 104 (ATM-104), which is spent fuel from Assembly DO47 of the Calvert Cliffs Nuclear Power Plant (Unit 1), a pressurized-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-104 consists of 128 full-length irradiated fuel rods with rod-average burnups of about 42 MWd/kgM and expected fission gas release of about 1%. A variety of analyses were performed to investigate cladding characteristics, radionuclide inventory, and redistribution of fission products. Characterization data include (1) fabricated fuel design, irradiation history, and subsequent storage and handling history; (2) isotopic ...

1991-12-01

363

Characterization of spent fuel approved testing material---ATM-105  

Energy Technology Data Exchange (ETDEWEB)

The characterization data obtained to data are described for Approved Testing Material 105 (ATM-105), which is spent fuel from Bundles CZ346 and CZ348 of the Cooper Nuclear Power Plant, a boiling-water reactor. This report is one in a series being prepared by the Materials Characterization Center at Pacific Northwest Laboratory (PNL) on spent fuel ATMs. The ATMs are receiving extensive examinations to provide a source of well-characterized spent fuel for testing in the US Department of Energy Office of Civilian Radioactive Waste Management (OCRWM) Program. ATM-105 consists of 88 full-length irradiated fuel rods with rod-average burnups of about 2400 GJ/kgM (28 MWd/kgM) and expected fission gas release of about 1%. Characterization data include (1) descriptions of as-fabricated fuel design, irradiation history, and subsequent storage and handling; (2) isotopic gamma scans; (3) fission gas analyses; (4) ceramography of the fuel and metallography ...

1991-12-01

364

Studies on gamma irradiated medicinal plants and spices (1): Myristica argentea, Myristica fragrans, Coriandrum sativum and Foeniculum vulgare  

Energy Technology Data Exchange (ETDEWEB)

Medicinal plants i.e. dried seeds of myristica argentea, myristica fragrans, coriandrum sativum and foeniculum vulgare were stored for 0 and 6 months, with and without gamma irradiation at 5 kGy. No detectable changes were seen in infrared and UV spectra, GLC chromatograms and refraction indices of steam distilled, essential oils from the irradiated medicinal plants. The same results were also obtained from irradiated samples stored for 6 months at ambient conditions. Storage for 6 months caused significant changes in the gas liquid chromatograms and UV spectra of all samples compared to non-stored samples. The moisture content of all samples packed in polyethylene bags seems to be constant after 6 months of storage. No measurable changes were found in the amount of essential oil content caused by irradiation.

1981-10-01

365

Spatial distribution of IGC-30 Ge-detector's efficiency  

International Nuclear Information System (INIS)

The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).

1993-12-02

366

Shielding augmentation for HFU penetration in calandria vault of 540 MWe PHWR  

International Nuclear Information System (INIS)

This paper consists the radiation streaming analysis of Horizontal Flux Unit (HFU) penetrations in Calandria Vault of 540 MWe PHWR. There are total 7 HFU penetrations on west wall of calandria vault. As these penetrations are in accessible area, a detailed analysis has been carried out to find the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out Using the computer code MCNP and DOT-III. Based on the predictions at HFU penetrations, shielding arrangement was recommended. Neutron and gamma dose rate higher than estimated were observed at TAPS-4. This was because of installed shield not being similar to recommended one due to site conditions. Subsequently semi-empirical calculations using measured data were carried out by MCNP to further augment the existing shield taking into consideration the space limitations at site. (author)

2006-11-13

367

Rare B decays  

Energy Technology Data Exchange (ETDEWEB)

The current status of rare B decays is reviewed based on recent observation of the penguin-diagram decay B {yields} K{sup *}{gamma} at CLEO. Rare B decays provide valuable information on the Standard Model parameters, and also could be a source of direct CP violation. It is emphasized that new physics beyond the Standard Model can appear in rare B decays, in some cases more drastically than in the CP Asymmetry of the B system. Inclusive measurement of the radiative transition b {yields} s{gamma} is promising. Hadronic penguin modes are very close to being observed at CLEO, and a discovery might be just around the corner. (author). 48 refs., 6 figs., 4 tabs.

1994-12-31

368

Radiosterilization of drugs in aqueous solutions may be achieved by the use of radioprotective excipients  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to assess the feasibility of radiosterilization of drugs aqueous solutions and to evaluate the effects of some additives, such as mannitol, nicotinamide and pyridoxine, which might protect the drug from degradation. Metoclopramide was selected as a model drug. The structures of the degradation products were determined to gain insight on the radiolysis mechanisms in aqueous solution in order to design strategies to lower the drug degradation.Metoclopramide hydrochloride aqueous solutions with and without excipients were irradiated either with gamma rays or high-energy electrons. HPLC-DAD was used to measure the loss of chemical potency and to quantify the degradation products which were also characterized by LC-APCI-MS-MS. Metoclopramide recovery for gamma and elec...

2008-01-01

369

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...

2006-10-29

370

Indirect Dark Matter Signals from EGRET and PAMELA compared  

CERN Document Server

Dark Matter annihilation (DMA) may yield an excess of gamma rays and antimatter particles, like antiprotons and positrons, above the background from cosmic ray interactions. The excess of diffuse Galactic Gamma Rays from EGRET shows all the features expected from DMA. The new precise measurements of the antiproton and positron fractions from PAMELA are compared with the EGRET excess. It is shown that the charged particles are strongly dependent on the propagation model used. The usual propagation models with isotropic propagation models are incompatible with the recently observed convection in our Galaxy. Convection leads to an order of magnitude uncertainty in the yield of charged particles from DMA, since even a rather small convection will let drift the charged particles in the halo to outer space. It is shown that such anisotropic propagation models including convection prefer a contribution from DMA for the ...

2009-01-01

371

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture ..gamma..-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1985-01-15

372

Evidence for valence transitions in neutron capture gamma-ray spectra in /sup 88/Sr  

International Nuclear Information System (INIS)

Neutron capture #gamma#-ray spectra have been measured at 11 average neutron energies from 10 to 530 keV in /sup 88/Sr using a 20 x 15 cm NaI detector with time-of-flight discrimination of background events. The partial radiation widths and the calculated partial valence widths are compared for the strong p-wave resonances at 287 and 321 keV and found to be highly correlated. At these energies, the spectra are dominated by strong transitions to low-lying single particle states, in confirmation of the role of valence capture in the 3p region. However, the data do not support this mechanism at <508> keV.

1984-09-10

373

Electronics Personal Dosemeter (EPD-N) Test and Evaluation Report  

Energy Technology Data Exchange (ETDEWEB)

Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.

2003-04-08

374

Effect of #gamma#-irradiation on commercial polypropylene based mono and multi-layered retortable food packaging materials  

International Nuclear Information System (INIS)

Irradiation processing of food in the prepackaged form may affect chemical and physical properties of the plastic packaging materials. The effect of #gamma#-irradiation doses (2.5-10.0 kGy) on polypropylene (PP)-based retortable food packaging materials, were investigated using Fourier transform infrared (FTIR) spectroscopic analysis, which revealed the changes happening to these materials after irradiation. The mechanical properties decreased with irradiation while oxygen transmission rate (OTR) was not affected significantly. Colour measurement indicated that Nylon 6 containing multilayer films became yellowish after irradiation. Thermal characterization revealed the changes in percentage crystallinity.

2007-07-01

375

Dislocation pinning in electron-irradiated copper as a function of electron energy and irradiation  

Science.gov (United States)

Dislocation priming measurements were performed in the kHz range in ASARCO copper. The samples and irradiation facilities are constructed so as to allow successive irradiation of samples both with electrons and gamma rays. The gamma rays were produced by stopping 2.8-MeV electrons in a gold target. The change of the type of irradiation could be achieved without any handling of the sample. Thus it is possible to detect rather small differences between the two types of irradiation. Recovery experiments at 400 deg K after 75 deg K irradiation and pinning rates during irradiation at 400 deg K and 75 deg K were made. (GE)

1973-01-01

376

Microscopic properties of passive films on Ti and Zr from optical, electrochemical and SXM-measurements  

International Nuclear Information System (INIS)

A combined application of several microtechniques is presented and discussed with the Ti/TiO_2 and Zr/ZrO_2-systems as an example. All measurements were carried out on single grains of technical materials in order to detect and quantify the effect of substrate microstructure on the properties of anodic passive films formed potentiodynamically in 0.5 M H_2SO_4 (dU/dt = 20 mVs"-"1). Anisotropy-micro-ellipsometry (AME) was employed to determine the crystallographic orientation of the substrate grains along with passive film thickness and crystallinity in dependence on the anodization potential. Both the isotropic (amorphous) TiO_2- and the anisotropic (crystalline) ZrO_2-films exhibit a systematic dependence of film thickness on the grain orientation. Local LASER-scanning photocurrent measurements (#lambda#=257 nm) on the same grains likewise show a heterogeneity of the photoelectrochemical reactivity in all cases. This is ...

1998-03-01

377

Study of porous silicon morphologies for electron transport  

International Nuclear Information System (INIS)

Field emitter devices are being developed for the gigatron, a high-efficiency, high frequency and high power microwave source. One approach being investigated is porous silicon, where a dense matrix of nanoscopic pores are galvanically etched into a silicon surface. In the present paper pore morphologies were used to characterize these materials. Using of Scanning Electron Microscope (SEM) and Transmission Electron Microscope (TEM) images of both N-type and P-type porous layers, it is found that pores propagate along the <100> crystallographic direction, perpendicular to the surface of (100) silicon. Distinct morphologies were observed systematically near the surface, in the main bulk and near the bottom of N-type (100) silicon lift-off samples. It is seen that the pores are not cylindrical but exhibit more or less approximately square cross sections. X-ray diffraction spectra and electron diffraction patterns verified that bulk porous silicon is still a ...

1993-05-17

378

Evaluation of heterogeneity in thickness of passive films on pure iron by scanning electrochemical microscopy  

Energy Technology Data Exchange (ETDEWEB)

Scanning electrochemical microscopy (SECM) was applied to evaluate the heterogeneity of a passive film formed on a pure iron electrode in deaerated pH 8.4 borate solution. A probe current image of SECM was measured with a tip-generation/sub-strate-collection (TO/SC) mode in deaerated pH 8.4 borate solution containing 0.03 moldm{sup -3} Fe(CN){sub 6}{sup 4-} as a mediator. The difference in thickness of passive films formed on two iron plates at different potentials could be evaluated from the probe current image. The probe current image of the passivated iron surface with distinctive crystal grains was composed of the patch patterns, the shapes of which coincided completely with the shapes of the substrate crystal grains. The probe current flowed above the grain surface oriented to {l_brace}100{r_brace} plane was less than that above the grain surface oriented to {l_brace}110{r_brace} or {l_brace}111{r_brace} plane. The grain orientation ...

1999-04-01

379

Measurement and interpretation of delayed photoneutron effects in multizone criticals with partial D{sub 2}O moderation  

Energy Technology Data Exchange (ETDEWEB)

The effective fraction of delayed photoneutrons ({beta}{sup ph}) has been theoretically defined and experimentally determined in various different configurations of the LWR-PROTEUS critical facility. The peculiarity lies in the fact that the reactor has D{sub 2}O in only one of the four fuelled zones, thus D({gamma},n)H reactions take place mainly in this region. The work is divided into three parts. The first part is devoted to the description of the LWR-PROTEUS facility and to the measurements of {beta}{sup ph}. These experimental values are derived from standard inverse-kinetics analysis of neutron flux decay experiments for each of seven different configurations, with nine additional groups of neutron precursors to account for photoneutron effects. In the second part, the coupled neutron and gamma Boltzmann equations are reduced to exact point kinetics equations using the photon infinite-velocity approximation, and then ...

2003-11-01

380

Accelerator aspects of #gamma#-#gamma# colliders  

International Nuclear Information System (INIS)

There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

381

Excited leptons and quarks at. gamma. gamma. /. gamma. e colliders  

Energy Technology Data Exchange (ETDEWEB)

We discuss the search of excited leptons and quarks with spin 1/2 at {gamma}{gamma} and at {gamma}e colliders. We show that {gamma}{gamma} colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l{sup *}l{gamma} transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).

1992-02-06

382

Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum  

CERN Document Server

Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.

2010-01-01

383

Measurement of level lifetimes in the ps range and model interpretations for neutron-rich A #approx =# 100 nuclei  

International Nuclear Information System (INIS)

The nuclear structure of A #propor to# 100 nuclei has been studied in the frame of this thesis with a recently developed #beta# - #gamma# - #gamma# triple coincidence fast timing technique and different models such as shell model, hydrodynamic model, Nilsson and particle-rotor models. This technique which allows the measurement of the level lifetimes in the ps range has been applied at JOSEF at the research reactor DIDO of KFA Juelich in studes of the short-lived neutron-rich nuclei in the A #approx =# 100 region. Lifetimes of level in "9"6,"9"8,"1"0"0 ZR, "9"9,"1"0"1-"1"0"4 Nb, "1"0"0-"1"0"5 Mo have been measured, which are in many cases completely new, and otherwise more precise than previously published data. From the lifetimes of the members of rotational bands, the size of the nuclear deformations has been deduced. (orig./HSI).

384

Measurement of "1"0"1Tc Half-Life  

International Nuclear Information System (INIS)

75 mg (NH_4)_6Mo_7O_24 #centre dot# 4H_2O solution was irradiated for 20 min in miniature neutron source reactor (MNSR) and cooled for 12 min. In the conditions of 0.8 mol/L HNO_3, phase ratio 1:1, the solution of "1"0"1Tc sample was extracted twice with #alpha#-benzoin oxime/ethyl acetate phase to remove "1"0"1Mo and a radiochemically pure and carrier-free "1"0"1Tc product was obtained. The half-life of "1"0"1Tc was accurately measured with a HPGe #gamma#-detector by following 306.8 keV #gamma#-ray about 150 min, and processed the data by three methods, R-value method, iterative method and translation method. Five parallel measurments gave a half-life (14.02 #+-# 0.01) min (n=5) for "1"0"1Tc. (authors)

2009-11-01

385

Limits on Anomalous Trilinear Gauge Couplings in Zgamma Events from ppbar Collisions at sqrt{s} = 1.96 TeV  

CERN Document Server

Using Zgamma candidate events collected by the CDF detector at the Tevatron Collider, we search for potential anomalous (non-standard-model) couplings between the Z boson and the photon. At the hard scatter energies typical of the Tevatron, standard model Zgamma couplings are too weak to be detected by current experiments; hence any evidence of couplings indicates new physics. Measurements are performed using data corresponding to an integrated luminosity of 4.9 /fb in the Z -> nunubar decay channel and 5.1 /fb in the Z -> l^+l^- (l=mu, e) decay channels. The combination of these measurements provides the most stringent limits to date on Zgamma trilinear gauge couplings. Using an energy scale of Lambda = 1.5 TeV to allow for a direct comparison with previous measurements, we find limits on the CP-conserving parameters that describe Zgamma couplings to be |h_3^{\\gamma,Z}| < 0.017 and ...

2011-01-01

386

Heat capacities between 1.5 and 16 K and superconductivity of V/H and Nb/H alloys  

International Nuclear Information System (INIS)

Molar heat capacities have been measured for VHsub(n) and NbHsub(n) with n up to 1.93 at temperatures between 1.5 and 16 K. The height of the peak in plots of the electronic specific heat, indicating superconductivity, diminishes with increasing hydrogen content in the #alpha# + #beta# two-phase region, and can be taken as a measure of the fractional amount of #alpha#-phase present (lever-rule). In NbHsub(n) accordingly, the two-phase region presumably extends up to n = approximately 0.9 at helium temperatures. No hydride phase, including VH_2 and NbH_2, showed superconductivity above 1.5 K. The measured #gamma#-coefficients of the V/H-alloys agree with APW band-structure calculations for V metal in the range 5 =< nsub(e) =< 7 of band electron concentration. They coincide with the #gamma#-coefficients of V/Cr-alloys reported in the literature. Hence VHsub(n) represents another ...

1977-05-01

387

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint ...

2009-06-07

388

Measurement of. beta. decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 less than or equal toA less than or equal to106 and A=109. Messung von Beta-Zellverfallsenergien kurzlebiger, neutronenreicher Atomkerne im Massenbereich 101 less than or equal toA less than or equal to106 und A=109  

Energy Technology Data Exchange (ETDEWEB)

Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values in keV). For the ...

1986-10-31

389

Measurement of #beta# decay energies of short-lived neutron-rich atomic nuclei in the mass range 101 #<=# A #<=# 106 and A=109  

International Nuclear Information System (INIS)

Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma ...

390

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light ...

1992-10-25

391

Measurement of $\\phi$(1020) meson leptonic width with CMD-2 detector at VEPP-2M Collider  

CERN Document Server

The $\\phi$(1020) meson leptonic width has been determined from the combined analysis of 4 major decay modes of the resonance ($\\phi\\to K^+ K^-,K^0_LK^0_S,\\pi^+\\pi^-\\pi^0,\\eta\\gamma$) studied with the CMD-2 detector at the VEPP-2M $e^+e^-$ collider. The following value has been obtained: $\\Gamma(\\phi\\to e^+e^-) = 1.235\\pm 0.006\\pm 0.022$ keV. The $\\phi(1020)$ meson parameters in four main decay channels have been also recalculated: $B(\\phi\\to K^+K^-) = 0.493\\pm 0.003\\pm 0.007$, $B(\\phi\\to K_LK_S) = 0.336\\pm 0.002\\pm 0.006$, $B(\\phi\\to\\pi^+\\pi^-\\pi^0) = 0.155\\pm 0.002\\pm 0.005$, $B(\\phi\\to\\eta\\gamma) = 0.0138\\pm 0.0002\\pm 0.0002$.

2010-01-01

392

Investigation of natural radionuclides in selected NORM-samples  

International Nuclear Information System (INIS)

A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, e.g. different densities, and the analysis ...

2005-09-20

393

Characterization of iron nitrides prepared by spark erosion, plasma nitriding, and plasma immersion ion implantation  

Energy Technology Data Exchange (ETDEWEB)

The effect of the nitrogen uptake in {alpha}-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic {alpha}-Fe phase (50%). The 20% of specimen volume form {alpha}'-Fe and {alpha}''-Fe{sub 16}N{sub 2} phases. The last 30% occupy the {gamma}'-Fe{sub 4}N, ferro- and paramagnetic {epsilon} phases, and {gamma}-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into {alpha}-iron particles which results in the formation of paramagnetic {epsilon}({zeta})-Fe{sub 2}N phase. This phase ...

2001-09-01

394

Characterization of iron nitrides prepared by spark erosion, plasma nitriding, and plasma immersion ion implantation  

International Nuclear Information System (INIS)

The effect of the nitrogen uptake in #alpha#-iron upon spark erosion in gaseous and liquid ammonia, plasma nitriding, and plasma immersion ion implantation is studied. The resulting phases and hyperfine parameters, measured by the Moessbauer spectroscopy, are discussed from the point of view of initial conditions of their preparation and subsequent heat and/or mechanical treatment. Spark erosion in the ammonia gas produces fine particles with the dominating ferromagnetic #alpha#-Fe phase (50%). The 20% of specimen volume form #alpha#'-Fe and #alpha#''-Fe_1_6N_2 phases. The last 30% occupy the #gamma#'-Fe_4N, ferro- and paramagnetic #epsilon# phases, and #gamma#-Fe(N). Nitriding in the liquid ammonia allows to incorporate the higher content of nitrogen into #alpha#-iron particles which results in the formation of paramagnetic #epsilon#(#zeta#)-Fe_2N phase. This phase also dominates the surface of #alpha#-iron specimen ...

2001-09-01

395

Backward pion photoproduction  

Energy Technology Data Exchange (ETDEWEB)

We present a systematic analysis of backward pion photoproduction for the reactions {gamma}p{yields}{pi}{sup 0}p and {gamma}p{yields}{pi}{sup +}n. Regge phenomenology is applied at invariant collision energies above 3GeV in order to fix the reaction amplitude. A comparision with older data on {pi}{sup 0}- and {pi}{sup +}-photoproduction at {theta}=180 indicates that the high-energy limit as given by the Regge calculation could be reached possibly at energies of around {radical}(s){approx_equal}3 GeV. In the energy region of {radical}(s){<=}2.5 GeV, covered by the new measurements of {gamma}p{yields}{pi}{sup 0} p differential cross-sections at large angles at ELSA, JLab, and LEPS, we see no clear signal for a convergence towards the Regge results. The baryon trajectories obtained in our analysis are in good agreement with those given by the spectrum of excited baryons. (orig.)

2009-04-15

396

"Discrepant hardenings" in cosmic ray spectra: a first estimate of the effects on secondary antiproton and diffuse gamma-ray yields  

CERN Document Server

Recent data from CREAM seem to confirm early suggestions that primary cosmic ray spectra at few TeV/nucleon are harder than in the 10-100 GeV range. Also, helium and heavier nuclei spectra appear systematically harder than the proton fluxes at corresponding energies. We note here that if the measurements reflect intrinsic features in the interstellar fluxes, appreciable modifications are expected in the sub-TeV range for the secondary yields, such as antiprotons and diffuse gamma-rays. Presently, this effect represents a systematic error in the extraction of astrophysical parameters as well as for background estimates for indirect dark matter searches. We find that the spectral modifications are appreciable above 100 GeV, and can be responsible for ~30% effects for antiprotons at energies close to 1 TeV or for gamma's at energies close to 300 GeV, compared to currently considered predictions based on simple extrapolation of ...

2010-01-01

397

Optimizing the acquisition time profile for a planar integral measurement system with a spinning slat collimator  

International Nuclear Information System (INIS)

This article considers a hypothetical imaging device with a spinning slat collimator that measures parallel-planar-integral data from an object. This device rotates around the object 180 deg. and stops at N positions uniformly distributed over this 180 deg. . At each stop, the device spins on its own axis 180 deg. and acquires measurements at M positions uniformly distributed over this 180 deg. . For a fixed total imaging time, an optimal distribution of the scanning time among the data measurement locations is searched by a nonlinear programming method: Nelder-Mead's simplex method. The optimal dwell time is approximately proportional to the weighting factor in the backprojector of the reconstruction algorithm. By using an optimal dwell-time profile, the reconstruction signal-to-noise ratio has a gain of 23%-24% for the filtered backprojection algorithm and a gain of 10%-18% for the iterative ...

2005-09-01

398

Cold SQUIDs and hot samples  

Energy Technology Data Exchange (ETDEWEB)

Low transition temperature (low-{Tc}) and high-{Tc} Superconducting QUantum Interference Devices (SQUIDs) have been used to perform high-resolution magnetic measurements on samples whose temperatures are much higher than the operating temperatures of the devices. Part 1 of this work focuses on measurements of the rigidity of flux vortices in high-{Tc} superconductors using two low-{Tc} SQUIDs, one on either side of a thermally-insulated sample. The correlation between the signals of the SQUIDs is a direct measure of the extent of correlation between the movements of opposite ends of vortices. These measurements were conducted under the previously-unexplored experimental conditions of nominally-zero applied magnetic field, such that vortex-vortex interactions were unimportant, and with zero external current. At specific temperatures, the authors observed highly-correlated noise sources, suggesting that ...

1997-05-01

399

Motion compensation with a scanned ion beam: a technical feasibility study  

UK PubMed Central (United Kingdom)

BackgroundIntrafractional motion results in local over- and under-dosage in particle therapy with a scanned beam. Scanned beam delivery offers the possibility to compensate target...Full Text Available

400

Vector Velocity Imaging Using Cross-Correlation and Virtual Sources  

DEFF Research Database (Denmark)

Previous investigations have shown promising results in using the directional cross-correlation method to estimate velocity vectors. The velocity vector estimate provides information on both velocity direction and magnitude. The direction is estimated by beamforming signals along directions in the range $[0^{\\circ}; 180^{\\circ}[$ and identifying the direction that produces the largest correlation across emissions. An estimate of the velocity magnitude is obtained from the spatial shift between signals beamformed along the estimated direction. This paper expands these investigations to include estimations of the vector velocities of a larger region by combining the estimations along several scan lines. In combination with a B-mode image, the vector velocities are displayed as an image of the investigated region with a color indicating the magnitude, and arrows showing the direction of the flow. Using the RASMUS experimental ultrasound scanner, ...

2006-01-01

401

Critical current measurements of high Tc superconductors in a scanning low temperature cryostat  

Energy Technology Data Exchange (ETDEWEB)

Maintaining uniformity of properties over long distances is one of the fabrication problems encountered with the new high {Tc} superconductors. Uniform properties are crucial in long tapes or wires with high critical current since local nonuniformities can limit the current carrying capacity of the whole piece. Transport critical currents in high {Tc} superconductors are conventionally measured with the contact 4-point probe DC current-voltage technique. This technique requires contact with the sample and and spatially averages over the region between the two voltage contacts. Two techniques have been used to infer the critical state model. The first uses the net magnetization of a suitably shaped sample in an external magnetic field. The second combines a DC magnetic field with AC induced currents to infer spatial flux profiles. The AC magnetization technique offers an advantage in that it is noncontacting; however, it also averages the ...

1991-01-01

402

Observation of eta_c(1S) and eta_c(2S) decays to K+ K- pi+ pi- pi0 in two-photon interactions  

CERN Document Server

We study the processes gamma gamma -> K^0_S K+/- pi-/+ and gamma gamma -> K+ K- pi+ pi- pi0 using a data sample of 519.2 fb-1 recorded by the BaBar detector at the PEP-II asymmetric-energy e+e- collider at center-of-mass energies near the Upsilon(nS) (n = 2,3,4) resonances. We observe the eta_c(1S), chi_c0(1P), chi_c2(1P), and eta_c(2S) resonances produced in two-photon interactions and decaying to K+ K- pi+ pi- pi0, with significances of 18.1, 5.7, 5.2, and 5.3 standard deviations (including systematic errors), respectively. We measure the eta_c(2S) mass and width in K^0_S K+/- pi-/+ decays, m(eta_c(2S))=3638.5 +/- 1.5 +/- 0.8 MeV/c^2 and Gamma(eta_c(2S)) = 13.4 +/- 4.6 +/- 3.2 MeV, where the first uncertainty is statistical and the second is systematic. We search for the Z(3930) resonance and find no significant signal. We also provide the two-photon ...

2011-01-01

403

Result analysis on the parameter test of radium specific activity calculation in the tailing of uranium mine No. 794  

International Nuclear Information System (INIS)

This paper first introduces the calculating method of radium specific activity to determine the radon emanation rate of tailing of uranium mine No. 794, the method needs two parameters: radon emanation coefficient and radon diffusion coefficient. According to the measured results of parameters and the contrast between radium specific activity of indoor chemical analysis of field sample and field gamma-ray spectra, the authors discuss the variation rules and characteristics of radon emanation coefficient and radon diffusion coefficient, and the best climate and seasons for measuring these parameters in northern China, and finally summarize the characteristics of this method through analyzing measured results. (authors)

2006-09-01

404

New neutron capture and total cross section measurements on {sup 88}Sr and their impact on s-process nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

The authors have made new and improved measurements of the neutron capture and total cross sections of {sup 88}Sr at the Oak Ridge Electron Linear Accelerator (ORELA). Improvements over previous measurements include a wider incident neutron energy range, the use of metallic rather than carbonate samples, better background subtraction, reduced sensitivity to sample-dependent backgrounds, and better pulse-height weighting functions. Because of its small cross section, the {sup 88}Sr(n,{gamma}) reaction is an important bottleneck during the s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. They describe the experimental procedures, compare the results to previous data, and discuss their astrophysical impact.

1998-11-01

405

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

406

Multiple ordered phases in the filled skutterudite compound PrOs4As12  

Energy Technology Data Exchange (ETDEWEB)

Magnetization, specific heat, and electrical resistivity measurements were made on single crystals of the filled skutterudite compound PrOs{sub 4}As{sub 12}. Specific heat measurements indicate an electronic specific heat coefficient {gamma} {approx} 50-200 mJ/mol K{sup 2} at temperatures 10 K {le} T {le} 18 K, and {approx} 1 J/mol K{sup 2} for t {le} 1.6 K. Magnetization, specific heat, and electrical resistivity measurements reveal the presence of two, or possibly three, ordered phases at temperatures below {approx} 2.3 K and in fields below {approx} 3 T. The low temperature phase displays antiferromagnetic characteristics, while the nature of the ordering in the other phase(s) has yet to be determined.

2006-03-20

407

Measurement of the total photoabsorption cross section on a proton in the energy range 600?1500 MeV at the GRAAL  

British Library Electronic Table of Contents (United Kingdom)

The total photoabsorption cross section on a free proton was measured at the GRAAL facility in the energy range E ? = 600?1500 MeV. The large-aperture LAGRAN?E detector and a liquid hydrogen target were used in the experiment performed with a back-scattered Compton gamma beam. To improve the accuracy, two alternative methods were employed. First, a subtraction method of using empty-target measurements allowed the cross section ? tot to be evaluated directly because of a low level of the electromagnetic background. Second, an algorithm for evaluating ? tot on the basis of summing the dominating partial cross sections was developed. Experimental results obtained for ? tot by the two methods are compared with existing data.

2008-01-01

408

First measurement of ADS parameters using B- -> D0K- decays in hadron collisions  

CERN Document Server

Measurements of branching fractions and CP-asymmetries of B^{-} \\rightarrow D^{0}K^{-} modes allow a theoretically-clean extraction of the CKM angle \\gamma. The method proposed by Atwood, Dunietz and Soni (ADS) makes use of a decay chain where color and Cabibbo suppression interfere, which produces large CP-violating asymmetries. The CDF experiment reports the first measurement at a hadron collider of branching fractions and CP-asymmetries of suppressed B^{-} \\rightarrow D^{0}h^{-} signals, where h is \\pi or K. Using 5.0 fb^{-1} of data we found a combined significance exceeding 5\\sigma and we determined the ADS parameters with accuracy comparable with B-factories.

2011-01-01

409

Development of a radon standard source  

Energy Technology Data Exchange (ETDEWEB)

The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density ...

2005-06-11

410

Research on laser welding of cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft  

Energy Technology Data Exchange (ETDEWEB)

Exploratory experiments of laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft were conducted. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. The corresponding mechanisms were discussed in detail. Results showed that the laser-welded seam had non-equilibrium solidified microstructures consisting of FeCr{sub 0.29}Ni{sub 0.16}C{sub 0.06} austenite solid solution dendrites as the dominant and some fine and dispersed Ni{sub 3}Al {gamma}' phase and Laves particles as well as little amount of MC short stick or particle-like carbides distributed in the interdendritic regions. The average microhardness of the welded seam was relatively uniform and lower than that of the base metal ...

2008-04-03

411

Research on laser welding of cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft  

International Nuclear Information System (INIS)

Exploratory experiments of laser welding cast Ni-based superalloy K418 turbo disk and alloy steel 42CrMo shaft were conducted. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM), X-ray diffraction (XRD), energy-dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. The corresponding mechanisms were discussed in detail. Results showed that the laser-welded seam had non-equilibrium solidified microstructures consisting of FeCr_0_._2_9Ni_0_._1_6C_0_._0_6 austenite solid solution dendrites as the dominant and some fine and dispersed Ni_3Al #gamma#' phase and Laves particles as well as little amount of MC short stick or particle-like carbides distributed in the interdendritic regions. The average microhardness of the welded seam was relatively uniform and lower than that of the base metal due to partial ...

2008-04-03

412

Dissimilar autogenous full penetration welding of superalloy K418 and 42CrMo steel by a high power CW Nd:YAG laser  

Energy Technology Data Exchange (ETDEWEB)

Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of {gamma}-FeCr{sub 0.29}Ni{sub 0.16}C{sub 0.06} austenite solid solution ...

2007-06-30

413

Dissimilar autogenous full penetration welding of superalloy K418 and 42CrMo steel by a high power CW Nd:YAG laser  

International Nuclear Information System (INIS)

Experiments of autogenous laser full penetration welding between dissimilar cast Ni-based superalloy K418 and alloy steel 42CrMo flat plates with 3.5 mm thickness were conducted using a 3 kW continuous wave (CW) Nd:YAG laser. The influences of laser welding velocity, flow rate of side-blow shielding gas, defocusing distance were investigated. Microstructure of the welded seam was characterized by optical microscopy (OM), scanning electron microscopy (SEM) and X-ray diffraction (XRD) and energy dispersive spectrometer (EDS). Mechanical properties of the welded seam were evaluated by microhardness and tensile strength testing. Results show that high quality full penetration laser-welded joint can be obtained by optimizing the welding velocity, flow rate of shielding gas and defocusing distance. The laser-welded seam have non-equilibrium solidified microstructures consisting of #gamma#-FeCr_0_._2_9Ni_0_._1_6C_0_._0_6 austenite solid solution ...

2007-06-30

415

Development of New Ground Inspection Techniques for the ...  

Science.gov (United States)

Integration of Eddy Current probes with MAUS scanning system has been demonstrated to produce scan rates of 36 sqft/hour. System will be designed to ...

416

Bone scanning in Ewing's sarcoma  

International Nuclear Information System (INIS)

In eight patients with Ewing's sarcoma bone scans were performed using "9"9"mTc-MDP. This procedure rendered possible the diagnosis of clinically or radiologically silent metastases. (orig.).

417

Acquisition of a High Resolution Field Emission Scanning Electron Microscope for the Analysis of Returned Samples  

Science.gov (United States)

This grant furnished funds to purchase a state-of-the-art scanning electron microscope (SEM) to

2003-01-01

418

{sup 252}Cf-source-driven frequency analysis measurements with subcritical arrays of PWR fuel pins  

Energy Technology Data Exchange (ETDEWEB)

Experiments with fresh PWR fuel assemblies were performed to assess the {sup 252}Cf-source-driven frequency analysis method for measuring the subcriticality of spent fuel. The measurements at the Babcox and Wilcox Critical Experiments Facility mocked up between 17x17 fuel pins (single assembly) and a full array of 4961 fuel pins (about 17 fuel assemblies) in borated water with a fixed B concentration. For the full array, the B content of the water was varied from 1511 at delayed criticality to 4303 ppM. Measurements were done for various source-detector-fuel pin configurations; they showed high sensitivity of frequency analysis parameters to B content and fissile mass. Parameters such as auto and cross power spectral densities can be calculated directly by a more general model of the Monte Carlo code (MCNP-DSP). Calculation-measurement comparisons are presented. This model permits the validation of ...

1996-08-01

419

Use of a predictor for total body potassium content: application to nutrition and hypertension  

International Nuclear Information System (INIS)

Total body potassium (TBK), measured at different institutions, has no reference standard for comparison. A useful reference formula, however, based on body size and age, has been derived at the Brookhaven National Laboratory. This formula was used to help calibrate a simple whole body counter for measuring total potassium and applied to nutrition and hypertension studies. A sodium iodide detector was used for counting gamma rays emitted by potassium-40 to estimate TBK. The mean ratio (+/- S.D.) of adjusted TBK measurements to predicted values was 1.002 +/- 0.047. The ratio of lean body mass estimated by the TBK measurement to that derived from skin fold thickness was 1.069 +/- 0.056. In hypertensives on low dose thiazide, the ratio of TBK measurements to predicted values was 0.994 +/- 0.052. Thus, our TBK measurements were adjusted in close ...

420

Measurement of inelastic charmonium production at HERA  

Energy Technology Data Exchange (ETDEWEB)

This thesis presents measurements of inelastic photoproduction and electroproduction of J/{psi} mesons in ep scattering at HERA. The data was collected by the H1 detector during the HERA II running and corresponds to an integrated luminosity of L {approx} 166 pb{sup -1} in the photoproduction analysis and L {approx} 315 pb{sup -1} in the electroproduction analysis. In both analyses the elasticity of the J/{psi} meson is restricted to a medium range of 0.3 {<=} z {<=} 0.9. The kinematic range of the photoproduction analysis is defined by Q{sup 2} {approx} 0 GeV{sup 2}, 60 {<=}W{sub {gamma}}{sub p}{<=} 240 GeV and P{sub {tau}}{sub ,{psi}}{>=} 1 GeV{sup 2}, whereas the electroproduction analysis is restricted to 3.6 {<=} Q{sup 2} {<=} 100 GeV{sup 2}, 50 {<=}W{sub {gamma}}{sub p}{<=} 225 GeV, and P{sup *}{sub {tau}}{sub ,} {sub {psi}} {>=} 1 GeV. Here P{sup ...

2008-09-15

421

Beta-delayed proton emission: a new series of precursors, and the measurement of 10"-"1"6 s nuclear lifetimes  

International Nuclear Information System (INIS)

The results of investigation into a new series of Z-even nuclei - precursors of delayed protons (PDP) -"6"5Ge, "8"9Se, "9"3Kr, "8"1Zr, and "8"5Mo are presented. PDP were obtained by irradiation of targets in the following reactions: Zn(He, 2n) "6"5Ge, 22 MeV; "4"0Ca("3"2S, 2 pn) "1"9Se, 100 MeV; "6"0Ni ("1"60, 3 n), "7"3Kr, 75 MeV; "5"2Cr ("3"2S, 3n)"8"1Zr, 110 MeV; "5"6Fe("3"2S, 3n)"8"5Mo, 120 MeV. The targets (self-sustaining foils of thickness approximately 1.2 mg/cm"2) were placed at an angle of 15 deg to the direction of the ion beam. Upon irradiation targets were moved downwards into a measuring position. The spectra of protons, X and gamma-rays, and also the spectra of p - x, p-#gamma#, x - #gamma# coincidences accompanying the decay of "6"5Ge, "6"9Se,"7"3Kr and "8"1Zr, and "8"5Mo were measured. The measured half-lives are equal, to 31.5+-1.9, 27.3+-0.5, ...

422

Study of scalar leptons at the TESLA Photon Collider  

International Nuclear Information System (INIS)

In this thesis, the potential to discover supersymmetric signatures in both e"+e"- and #gamma##gamma# colliders evaluated with a Monte Carlo analysis, is discussed. The analysis was focused on the detection of muons, essentially. First, we study the detection of #mu#"+_R#mu#"-_R in e"-e"+ collisions, whose purpose is the measurement of the #mu#_R mass. It was found that an uncertainty of 0.11 GeV (stat) can be achieved. Under the assumption of the real conditions of the ILC photon collider, a study covering the detection of #mu#"+_R#mu#"-_R and #mu#"+_L#mu#"-_L pairs for #sq root#(s_e_"-_e_"+)=0.5 and 0.6 TeV was performed. According to the simulation, a statistical error for the branching ratios of #mu#"#+-#_L#->##chi#"0_1#mu#"#+-# of 0.98% and #mu#"#+-#_L#->##chi#"0_2#mu#"#+-# of 3.97% can be reached. In order to judge the Monte Carlo results, we have used a technique based on a multidimensional fit to evaluate the impact of the ...

423

High-efficiency Resonant rf Spin Rotator with Broad Phase Space Acceptance for Pulsed Polarized Cold Neutron Beams  

Energy Technology Data Exchange (ETDEWEB)

High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on adiabatic fast passage. We discuss the design of the spin rotator and describe two types of ...

2008-08-01

424

#sigma#_e_e_#gamma#_#gamma#"t"o"t at e"+e"- colliders  

International Nuclear Information System (INIS)

In this talk I briefly summarize different models for #sigma#_2_#gamma#"t"o"t (e"+e"-#->##gamma##gamma##->#hadrons) and contrast model predictions with the data. I will then discuss the capability of the future e"+e"- and #gamma##gamma# colliders to distinguish between various models and end with an outlook for future work.

2001-07-09

425

In situ scanning tunneling microscope study of the passivation of Cu(111)  

Energy Technology Data Exchange (ETDEWEB)

In situ scanning tunneling microscopy has been used to study the nucleation and growth mechanisms and the structure of passive films formed on Cu(111) surfaces in 0.1 M borate buffer solution (pH 9.3). A surface topography characterized by terraces with monoatomic steps is obtained after potentiodynamic reduction down to {minus}1.12 V/standard hydrogen electrode (SHE), of the electropolished surface exposed to air. The formation of a single Cu{sub 2}O passive layer at 0.03 V/SHE proceeds first by a roughening of the steps assigned to a locally blocked step flow process due to a competition between dissolution and preferential nucleation of the oxide at the steps. The observed oxide nuclei are 2--3 nm wide and about one atomic plane high. This process leads to the complete coverage of the terraces by a grain-like structure of the oxide film. The initial terrace topography is completely altered. Thickening of this oxide layer leads to unstable ...

1999-02-01

426

Chargino production at high energy {gamma}{gamma} colliders with polarized beams  

Energy Technology Data Exchange (ETDEWEB)

We investigate the chargino production process {gamma}{gamma} {yields} (W-tilde){sup +}(W-tilde){sup -} at high energy {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy {gamma} beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background {gamma}{gamma} {yields} W{sup +}W{sup -}. (author).

1995-05-01

427

Chargino production at high energy #gamma##gamma# colliders with polarized beams  

International Nuclear Information System (INIS)

We investigate the chargino production process #gamma##gamma# #-># (W-tilde)"+(W-tilde)"- at high energy #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy #gamma# beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background #gamma##gamma# #-># W"+W"-. (author).

1995-05-01

428

gamma. /sub 5/ in dimensional regularization  

Energy Technology Data Exchange (ETDEWEB)

By generalizing the algebra satisfied by the ..gamma../sub 5/ matrix, it is possible to give an extension of ..gamma../sub 5/ to d dimensions. We discuss the connection of this scheme to others.

1985-02-07

429

Whole-body counting in the Marshall Islands  

Energy Technology Data Exchange (ETDEWEB)

In 1978 the Marshall Islands Radiological Safety Program was organized to perform radiation measurements and assess radiation doses for the people of the Bikini, Enewetak, Rongelap and Utirik Atolls. One of the major field components of this program is whole- body counting (WBC). WBC is used to monitor the quantity of gamma- emitting radionuclides present in individuals. A primary objective of the program was to establish {sup 137}Cesium body contents among the Enewetak, Rongelap and Utirik populations. {sup 137}Cs was the only gamma-emitting fission radionuclide detected in the 1,967 persons monitored. {sup 137}Cs body burdens tended to increase with age for both sexes, and were higher in males. The average {sup 137}Cs dose Annual Effective Dose for the three populations was as follows: For Enewetak, the dose was 22{+-}4 {mu}Sv. For Utirik, the dose was 33{+-} 3 {mu}Sv. Since 1985 the Rongelap people have been self-exiled ...

1991-01-01

430

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

Energy Technology Data Exchange (ETDEWEB)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino ...

1993-12-31

431

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

International Nuclear Information System (INIS)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino ...

432

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation ...

1999-07-01

433

The lightest Higgs Boson of mSUGRA, mGMSB and mAMSB at Present and Future Colliders Observability and Precision Analyses  

CERN Document Server

We investigate the physics of the lightest CP-even MSSM Higgs boson at the Tevatron, the LHC, a linear e+e- collider, a gamma gamma collider and a mu+mu- collider. The analysis is performed in the three most prominent soft SUSY-breaking scenarios, mSUGRA, mGMSB and mAMSB. For all colliders the observability and parameter regions with suppressed production cross sections (compared to a SM Higgs boson with the same mass) are investigated. For the lepton and photon colliders the potential is analyzed of precision measurements of the branching ratios of the light CP-even Higgs boson for obtaining indirect bounds on the mass of the CP-odd Higgs boson and the high-energy parameters of the soft SUSY-breaking scenarios. In regions of the parameter space where the LHC can detect the heavy Higgs bosons, precision measurements of the properties of the light Higgs boson at the linear collider can provide valuable ...

2003-01-01

434

Selective dissolution and surface enrichment of alloy components of passivated Fe 18Cr and Fe 18Cr3Mo single crystals  

International Nuclear Information System (INIS)

The possible surface enrichment of chromium and molybdenum during dissolution of Fe18Cr (110) and Fe18Cr3Mo (110) alloys at constant potentials in the passive region is elucidated by taking into account quantitative information on partial dissolution rates of alloy components as measured by #gamma#-spectrometry and on chemical composition of passivating films as measured by ESCA and AES. When combining results from all methods it is found that chromium under all conditions is enriched in the passivating films. An accumulation of chromium in the alloy is also indicated. For molybdenum, an enrichment in the passive film is observed at -0.2 V (SCE), whereas in the potential interval 0.1 - 0.9 V, the molybdenum enrichment as determined by ESCA and AES is hardly significant. On the other hand, #gamma#-spectrometry gives a clear indication of molybdenum enrichment in both potential. (author).

2008-12-30

435

Radiochemical detector cross section sensitivity studies in the A approx. = 90 mass region  

Energy Technology Data Exchange (ETDEWEB)

The use of radiochemical detectors in the A approx. = 90 mass region to measure 14 MeV neutron fluences is investigated from the standpoint of cross section sensitivities. Specifically, /sup 90/Zr and /sup 89/Y neutron-induced cascades leading to the production of /sup 89/Zr, /sup 88/Zr, /sup 88/Y, and /sup 87/Y are studied in a one-energy-group approximation, and the sensitivities of the measured ratios R/sub Z/ = /sup 88/Zr//sup 89/Zr and R/sub Y/ = /sup 87/Y//sup 88/Y to the input cross sections are delineated. The most sensitive cross section in each cascade is the cross section that dominates the production of the final isotope in the chain. Only one of the isomeric levels in /sup 90/Zr contributes importantly to the Zr cascade. Burnback (n,..gamma..) and burnup (n,p) reactions are also considered. The (n,..gamma..) effects are small, but (n,p) effects can be substantial due to low energy ...

1984-04-05

436

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

437

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

438

Evidence of polarisation in the prompt gamma-ray emission from GRB 930131 and GRB 960924  

CERN Document Server

The true nature of the progenitor to GRBs remains elusive; one characteristic that would constrain our understanding of the GRB mechanism considerably is gamma-ray polarimetry measurements of the initial burst flux. We present a method that interprets the prompt GRB flux as it Compton scatters off the Earth's atmosphere, based on detailed modelling of both the Earth's atmosphere and the orbiting detectors. The BATSE mission aboard the \\textit{CGRO} monitored the whole sky in the 20 keV - 1 MeV energy band continuously from April 1991 until June 2000. We present the BATSE Albedo Polarimetry System (BAPS), and show that GRB 930131 and GRB 960924 provide evidence of polarisation in their prompt flux that is consistent with degrees of polarisation of $\\Pi>35$% and $\\Pi>50$% respectively. While the evidence of polarisation is strong, the method is unable to strongly constrain the degree of polarisation beyond a systematics based estimation. ...

2005-01-01

439

Environmental pollutant isotope measurements and natural radioactivity assessment for North Tushki area, south western desert, Egypt  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials under certain conditions can reach hazardous radiological levels. The natural radionuclide ({sup 238}U, {sup 232}Th, {sup 40}K) contents of rock samples at various locations in the North Tushki area were investigated using gamma-spectrometric analysis. Estimates of the measured radionuclide content have been made for the absorbed dose rate of gamma radiation. The equivalent radium (R{sub eq}) and the external hazard index (H{sub ex}) which resulted from the natural radionuclides in soil are also calculated and tabulated. The studied samples have been collected from various rock exposures in the North Tushki area. The distribution of major oxides, U and Th were studied. It is found that the enrichment and depletion of the major oxides are mainly due to the effect of hydrothermal alteration, which caused mobility of some major oxides, which increases some elements and decreases others. It is ...

2002-09-01

440

Electronic structure and nesting-driven enhancement of the RKKY interaction at the magnetic ordering propagation vector in Gd_2PdSi_3 and Tb_2PdSi_3  

International Nuclear Information System (INIS)

We present first-time measurements of the Fermi surface and low-energy electronic structure of intermetallic compounds Gd_2PdSi_3 and Tb_2PdSi_3 by means of angle-resolved photoelectron spectroscopy (ARPES). We show that the Fermi surface in both compounds consists of an electron barrel at the #GAMMA# point surrounded by spindle-shaped electron pockets originating from the same band, with the band bottom of both features lying at 0.5 eV below the Fermi level. From the experimentally measured band structure, we estimate the momentum-dependent RKKY coupling strength and demonstrate that it is peaked at the 1/2#GAMMA# K wave vector. Comparison with neutron diffraction data from the same crystals shows perfect agreement of this vector with the propagation vector of the low-temperature in-plane magnetic order, thereby demonstrating the decisive role of the Fermi surface geometry in explaining the complex ...

2009-03-22

441

Determination of the surface properties calcite treated with stearic acid by Inverse Gas Chromatography  

Energy Technology Data Exchange (ETDEWEB)

The values of -{delta}G{sub A}{sup O} of n-alkanes on calcite are lower on the stearic acid treated calcite than on the untreated calcite. The value of -{delta}G{sub A}{sup O} of n-alkanes on calcite increase with increasing carbon numbers of n-alkanes. The values of -{delta}G{sub A}{sup O} measured on the treated calcite are significantly lower than those measured on the untreated calcite. The -{delta}G{sub A}{sup O} of n-alkanes on the treated calcite are close to the heat of liquefaction of n-alkanes. All the experimental values of -{delta}G{sub A}{sup O} of n-alkanes on calcite are larger than theoretical entropy decrease particularly for the higher molecular mass n-alkanes. Thus the important entropy decrease observed upon adsorption can not only be attributed to the loss of one degree of freedom of the adsorbed molecules. The values of {gamma}{sub S}{sup D} of the treated and untreated calcite decrease with increasing ...

1999-10-31

442

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. ...

1988-10-01

443

X-ray Microdiffraction and Strain Gradient Crystal Plasticity Studies of Geometrically Necessary Dislocations Near a Ni Bicrystal Grain Boundary  

Energy Technology Data Exchange (ETDEWEB)

We compare experimental measurements of inhomogeneous plastic deformation in a Ni bicrystal with crystal-plasticity simulations. Polychromatic X-ray microdiffraction, orientation imaging microscopy and scanning electron microscopy, were used to characterize the geometrically necessary dislocation distribution of the bicrystal after uniaxial tensile deformation. Changes in the local crystallographic orientations within the sample reflect its plastic response during the tensile test. Elastic strain in both grains increases near the grain boundary. Finite element simulations were used to understand the influence of initial grain orientation and structural inhomogeneities on the geometrically-necessary dislocations arrangement and distribution and to understand the underlying materials physics.

2009-01-01

444

The formation and removal characteristics of aerosols in ammonia-based wet flue gas desulfurization  

British Library Electronic Table of Contents (United Kingdom)

The characteristics of aerosol generation were studied experimentally in an ammonia-based wet flue gas desulfurization process. Particle size distributions and concentrations, morphologies and compositions before and after desulfurization were measured using an electrical low pressure impactor and scanning electron microscopy, respectively. The results show that aerosols can be generated between ammonia and sulfur dioxide resulting in gas-phase reaction and the aerosol concentration at the outlet of scrubber is significantly higher than at the inlet. Before desulfurization the particles are primarily silica-alumina minerals including O, Al, Si and C, while after ammonia-based desulfurization aerosol particles have smooth surfaces with regular structures, such as cubic and prismatic crystal...

2011-01-01

445

Synthesis and enhanced light absorption of alumina matrix nanocomposites containing multilayer oxide nanorods and silver nanoparticles  

British Library Electronic Table of Contents (United Kingdom)

In this paper, multilayer oxide nanorods were deposited in the nanopores of anodic aluminum oxide (AAO) via solution infiltration followed by heat treatment. The nanorods have a core-shell structure. First, the shell (nanotube) with the thickness of about 40nm was made of TiO"2 through the hydrolysis of (NH"4)"2TiF"6. Second, silver nanoparticles with the diameter of about 3nm were added into the TiO"2 layer through thermal decomposition of AgNO"3 at elevated temperatures. Then, cylindrical cores (nanorods) of CoO and ZnO with 200nm diameter were prepared, respectively. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to characterize the structure and composition of the nanorods. UV-vis light absorption measurements in the wavelength range from 350 to...

2011-01-01

446

Synthesis and characterization of myristic acid capped silver nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

Reduction of silver myristate (AgMy) under mild thermal reaction conditions in a dipolar aprotic solvent i.e. N, N-dimethylformamide (DMF) has been carried out. UV-visible absorption measurements of dried and re-dispersible brown flocculants showed broad features of surface plasmon resonance (SPR) due to silver nanoparticles. The freshly isolated particles showed absorption bands at 414 and 485 nm, respectively, due to inter-particle coupling or clustering of silver ions and silver atoms. X-ray diffraction (XRD) pattern of fcc zero-valent silver resulted in crystallite size of about 10 nm. Scanning electron microscopy (SEM) revealed formation of rod shaped silver with increasing reaction temperature. Thermal analysis (TGA) showed about 10% weight loss due to organic capping.

2008-08-15

447

Synthesis and characterization of Fe3O4Gg nanocomposites and their antibacterial performance  

British Library Electronic Table of Contents (United Kingdom)

We synthesized Fe3O4Gg nanocomposites through a combination of solvothermal, hydrothermal, and chemical redox reactions. Characterization of the resulting samples by X-ray diffraction, Fourier-transform infrared spectroscopy, field-emission scanning and transmission electron microscopy, and magnetic measurement is reported. Compared to Fe3O4g nanocomposites, the Fe3O4Gg nanocomposites showed enhanced antibacterial activity. The Fe3O4Gg nanocomposites were able to almost entirely prevent growth of Escherichia coli when the concentration of Ag nanoparticles was 10mg/mL. Antibacterial activity of the Fe3O4Gg nanocomposites was maintained for more than 40h at 37^oC. The intermediate carbon layer not only protects magnetic core, but also improves the dispersion and antibacterial activity of the...

2011-01-01

448

Study of surface segregation of Si on palladium silicide using Auger electron spectroscopy  

International Nuclear Information System (INIS)

The transformation of Pd/Si to Pd_2Si/Si is studied using Auger electron spectroscopy over a wide temperature range of 370-1020 K. The Pd film gets totally converted to Pd_2Si upon annealing at 520 K, and beyond 570 K, Si starts segregating on the surface of silicide. It is found that the presence of surface oxygen influences the segregation of Si. The time evolution study of Si segregation reveals that segregation kinetics is very fast and the segregated Si concentration increases as the temperature is increased. Scanning electron microscopy measurements show that Pd_2Si is formed in the form of islands, which grow as the annealing temperature is increased.

2004-11-21

449

SSRM characterisation of FIB induced damage in silicon  

International Nuclear Information System (INIS)

Scanning spreading resistance microscopy (SSRM) has been applied to study focused ion beam (FIB) induced damage in silicon in dependence on ion irradiation doses from 10"1"2 cm"-"2 to 2#centre dot#10"1"6 cm"-"2. Starting from the lowest dose, SSRM detects increasing spreading resistance (SR) with increasing dose. For doses from 2#centre dot#10"1"3 cm"-"2 to 4#centre dot#10"1"4 cm"-"2, a slight decrease of SR is measured whereas for higher doses SR again slightly increases. The results are explained by physical effects like decreased carrier mobility due to increased scattering, amorphisation of silicon and precipitation of implanted Ga ions. The results clearly prove that SSRM is well suited for the fast detection of ion beam induced damage with high lateral resolution.

2008-03-01

450

Real time automatic discriminating of ultrasonic flaws  

International Nuclear Information System (INIS)

This paper is concerned with the real time automatic discriminating of flaws from two categories; i. cracks (planar defect) and ii. Non-cracks (volumetric defect such as cluster porosity and slag) using pulse-echo ultrasound. The raw ultrasonic flaws signal were collected from a computerized robotic plane scanning system over the whole of each reflector as the primary source of data. The signal is then filtered and the analysis in both time and frequency domain were executed to obtain the selected feature. The real time feature analysis techniques measured the number of peaks, maximum index, pulse duration, rise time and fall time. The obtained features could be used to distinguish between quantitatively classified flaws by using various tools in artificial intelligence such as neural networks. The proposed algorithm and complete system were implemented in a computer software developed using Microsoft Visual BASIC 6.0 (author)

2009-07-20

451

Preparation and characterization of nano hydroxyapatite/polymeric composites materials. Part I  

British Library Electronic Table of Contents (United Kingdom)

The present study is focused on preparation of nano composite materials and the effect of citric acid on their different properties. The formation of nano HA and its interaction with chitosan (C), gelatin (G) polymers and citric acid (CA) materials were studied. The Fourier Transformed Infrared Spectroscopy (FT-IR), X-ray diffraction (XRD), thermo-gravimetric analysis (TGA), transmission electron microscope (TEM), and scanning electron microscope (SEM) were used to characterize these composite materials. The compressive strength (CS) was also measured to know the reinforcement of the prepared composites. The results show that carboxylic and amino groups play crucial role for HA formation on chitosan-gelatin polymeric matrix in the presence of citric acid (CA). The formation of nano HA part...

2011-01-01

452

Plasma nitriding of microalloyed steel  

Energy Technology Data Exchange (ETDEWEB)

Microalloyed or high strength low alloy (HSLA) steels are carbon-manganese steels containing small amounts of Nb, V or Ti. The excellent mechanical properties of these alloys, particularly high yield strength, usually obviate the need for expensive quench and tempering operations. Furthermore, the presence of a significant amount of nitride-forming elements in some microalloyed steels has generated interest in the applicability of these alloys as a new generation of nitriding steels. In this paper, a study of the plasma nitriding behaviour of a commercially available microalloyed steel MAXIMA{sup TM} is reported. A comparison is made with a traditional quenched and tempered nitriding steel (En19), plasma nitrided under similar conditions. Optical and scanning electron microscopy in conjunction with microhardness measurements and X-ray diffraction were utilized to characterize the nitrided surfaces. The observed differences in the thickness and ...

1995-03-01

453

On plasma nitriding of steels  

Energy Technology Data Exchange (ETDEWEB)

With the aim of optimizing the nitriding process, experimental studies of the plasma nitriding of four selected steels were carried out, using a d.c. glow discharge. The process parameters were varied systematically. By means of transmission and scanning electron microscopy and X-ray diffraction, the microstructures, including the thicknesses of the compound zones and the diffusion zones of the nitrided steels, were obtained. Using cross-sectional samples and a micro-Vickers indenter, hardness depth profiles were also obtained. From the time and temperature dependences of the hardness profiles, effective diffusion constants and corresponding activation enthalpies were obtained. Furthermore, in an attempt to shed some light on the atomistic nitriding mechanisms, the glow discharges were studied by measuring energy spectra of the energetic ions hitting the cathode (the steel test specimens). It was shown that an increase of the mean energy of the ...

2000-02-01

454

New starches: Physicochemical properties of sweetsop (Annona squamosa) and soursop (Anonna muricata) starches  

British Library Electronic Table of Contents (United Kingdom)

Starch from the fruits of sweetsop (Anonna squamosa) and soursop (Anonna muricata) were isolated and purified and the fat, ash, phosphorus and protein contents measured. The amount of amylose present was determined spectrophotometrically and found to be very similar (19%) for both starches. Scanning electron microscopy showed very small indented and spherical granules from both with an average granule size of 4.84mm and 4.72mm, respectively. The physicochemical properties, namely the swelling power, solubility, pasting characteristics, paste clarity and freeze-thaw stability were studied to assess the functionality of the starch pastes as hydrocolloids. The sweetsop starch showed higher swelling power and solubility compared to soursop starch and had a lower gelatinization temperature indi...

2009-01-01

455

Morphology and properties of silane-modified montmorillonite clays and clay/PBT composites  

British Library Electronic Table of Contents (United Kingdom)

Commercially available organoclay (Closite 30B) was modified by using 3-aminopropyltriethoxysilane (APS) via a silylation reaction. Sodium clay (Closite Na) was treated by APS directly as a control. Such modified clays were further melt-compounded with polybutylene terephthalate (PBT). The morphology and properties of the modified organoclays were characterized with X-ray diffraction (XRD), transmission electrical microscopy (TEM), Infra-red spectroscopy, contact angle measurement, and thermogravimetric analysis (TGA). The effects of modified clays on the crystallization behavior of PBT were characterized by differential scanning calorimetry. The basal spacing of Closite Na was enlarged from 1.01 to 1.41 nm after APS treatment, indicating that the APS was intercalated into the clay interga...

2008-01-01

456

Investigation into some tribological properties of plasma nitrided hot-worked tool steel AISI H11  

Energy Technology Data Exchange (ETDEWEB)

Interest in the tribological properties of plasma nitriding has increased substantially over the past years because plasma nitriding provides a high nitride depth and improved hard facing. The present study examines the tribological properties of AISI H11 plasma nitrided, hot-worked steel. Different nitriding temperatures and durations were considered. Characterization of the composite structures was investigated with wear tests, x-ray diffraction (XRD) analysis, scanning electron microscopy (SEM), and microhardness tests. The depth profile of the nitrided zone was measured using the nuclear reaction analysis (NRA) technique. Plasma nitriding affected the microhardness, wear properties, and morphology considerably. Increase in process temperature increased the nitride zone depth.

1996-04-01

457

Environmentally conscious sintered glass-ceramics  

Energy Technology Data Exchange (ETDEWEB)

Sintered glass-ceramics have been produced using municipal incinerator solid residues and glass cullet or an inert waste, from feldspars processing, as sintering aids. The capability of three different mixtures, either previously vitrified or not, to be sintered was investigated by means of linear shrinkage, water absorption and bulk density measurements, and by X-ray diffraction analysis and scanning electron microscopy observations. Particular attention has been addressed to the study of particle size effect on the sintering process. The conclusions that can be drawn from the experimental study are that the preliminary vitrification step is essential in order to obtain a dense sintered glass-ceramic product in the 850-1050 C temperature range developing silicate crystalline phases. The optimal powder particle size that confers a good densification degree was found to be < 45 {mu}m. (orig.)

2002-07-01

458

Enhancement of convective heat transfer by using microencapsulated PCM slurry  

Energy Technology Data Exchange (ETDEWEB)

As a method to make use of a high latent heat of a liquid-solid phase change material in a confined convective heat transfer, a phase change material, lauric acid, was encapsulated in a tiny hollow sphere, and mixed with water, forming a slurry of microencapsulated phase-change material (MCPCM slurry). Four different sizes (200, 100, 50, and 25 {mu}m ID) of MCPCMs were tested in this study. Thermal characteristics of the pure lauric acid and lauric acid MCPCMs were tested by a differential scanning calorimeter. Viscosity of the slurries of water and the capsules was measured by a rotating viscometer. The slurries were also tested in a convective-heat-transfer-test apparatus. (author). 11 refs., 5 figs., 1 tab.

1998-11-01

459

Electrochemical method for the synthesis of silver nanoparticles  

Energy Technology Data Exchange (ETDEWEB)

The article deals with a novel electrochemical method of preparing long-lived silver nanoparticles suspended in aqueous solution as well as silver powders. The method does not involve the use of any chemical stabilising agents. The morphology of the silver nanoparticles obtained was studied using transmission electron microscopy, scanning electron microscopy, atomic force microscopy and dynamic light scattering measurements. Silver nanoparticles suspended in water solution that were produced by the present technique are nearly spherical and their size distribution lies in the range of 2 to 20 nm, the average size being about 7 nm. Silver nanoparticles synthesised by the proposed method were sufficiently stable for more than 7 years even under ambient conditions. Silver crystal growth on the surface of the cathode in the electrochemical process used was shown to result in micron-sized structures consisting of agglomerated silver nanoparticles ...

2009-07-15

460

Electrical properties and x-ray diffraction of wood and wood plastic composite (WPC)  

Energy Technology Data Exchange (ETDEWEB)

Wood plastic composite (WPC) of kadom, simul, mango and debdaro were prepared with two monomers methylmethacrylate (MMA) and butylmethacrylate (BMA) using high energy ionizing radiation. X-ray diffraction and scanning electron microscope (SEM) studies reveal that significant grafting occurred with wood fiber. Electric properties like resistivity and dielectric constant of both wood and WPC were measured under different moisture contents and relative humidities. The resistivities of wood decreased dramatically with increase of moisture content, but those of WPC decreased very slowly with moisture content. The dielectric constant of wood increased significantly with moisture content but no significant difference was observed in the case of WPC within the range of moisture contents studied. The dielectric constants of untreated wood also increased with their densities. (author).

1991-01-01

461

Effects of coolant chemistry on corrosion of 3003 aluminum alloy in automotive cooling system  

British Library Electronic Table of Contents (United Kingdom)

In this work, effects of coolant chemistry, including concentrations of chloride ions and ethylene glycol and addition of various ions, on corrosion of 3003 Al alloy were investigated by electrochemical impedance spectroscopy measurements and scanning electron microscopy characterization. In chloride-free, ethylene glycol-water solution, a layer of Al-alcohol film is proposed to form on the electrode surface. With the increase of ethylene glycol concentration, more Al-alcohol film is formed, resulting in the increase in film resistance and charge-transfer resistance. In the presence of Cl- ions, they would be involved in the film formation, decreasing the stability of the film. In 50% ethylene glycol-water solution, the threshold value of Cl- concentration for pitting initiation is within ...

2010-01-01

462

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

463

Computational mouse atlases and their application to automatic assessment of craniofacial dysmorphology caused by the Crouzon mutation Fgfr2C342Y  

British Library Electronic Table of Contents (United Kingdom)

Abstract Crouzon syndrome is characterized by premature fusion of sutures and synchondroses. Recently, the first mouse model of the syndrome was generated, having the mutation Cys342Tyr in Fgfr2c, equivalent to the most common human Crouzon/Pfeiffer syndrome mutation. In this study, a set of micro-computed tomography (CT) scannings of the skulls of wild-type mice and Crouzon mice were analysed with respect to the dysmorphology caused by Crouzon syndrome. A computational craniofacial atlas was built automatically from the set of wild-type mouse micro-CT volumes using (1) affine and (2) non-rigid image registration. Subsequently, the atlas was deformed to match each subject from the two groups of mice. The accuracy of these registrations was measured by a comparison of manually placed landma...

2007-01-01

464

Analysis of the different slip systems activated by tension in a #alpha#/#beta# titanium alloy in relation with local crystallographic orientation  

International Nuclear Information System (INIS)

The gliding modes of a duplex Ti-6Al-4V titanium alloy were investigated through in situ (scanning electron microscopy) tensile tests. A method based on electron back-scattering diffraction (EBSD) measurements was used to identify activated slip systems. The approach applied to a large number of grains allowed a statistical analysis of the nature (basal, prismatic, pyramidal) and distribution of the slip systems according to the crystallographic texture. A discussion concerning the pertinence of Schmid's law to explain the occurrence and succession of slip events is then proposed. The domain in favor of each type of slip system is finally presented by using inverse pole figures mapped with Schmid's factor iso-curves.

2005-02-01

465

Structural changes in amorphous Pd_8_0Si_2_0 and Pd_7_7_._5 Cu_6 Si_1_6_._5 alloys caused by neutron irradiation  

International Nuclear Information System (INIS)

The present work is to study effects of neutron irradiation on the structure of amorphous Pb_8_0 Si_2_0 and Pd_7_7_._5 Cu_6 Si_1_6_._5 alloys by using X-ray diffraction techniques. differential scanning calorimertry (DSC) and internal friction measurements. The irradiation will produce obvious changes in the pair correlation function g(r) and radial distribution function RDF (r). The increase of crystallization temperature (Tx) and enthalpy of two specimens were found by DSC measurements after irradiation. The results of internal friction measurement show that the internal friction of the irradiated Pd_8_0Si_2_0 alloy is higher than that of the unirradiated in the temperature range of T

466

Properties of superconducting Cu-rich composites containing V_3Si or V_3Ga  

International Nuclear Information System (INIS)

Superconducting Cu-rich composites containing the A-15 compounds V_3Si or V_3Ga were made by the ''Tsuei'' process (melting into ingots followed by cold working and heat treatment). Superconducting transition temperatures of the composites were measured. X-ray diffraction analyses were performed. Microstructures were studied using both the optical metallograph and the scanning electron microscope. For some composites containing V_3Ga, the critical current densities as functions of transverse magnetic field up to 60 kG, and as functions of temperature from 4.2 to 12"0K were measured. It was found that the Tsuei process does not work for the composites containing V_3Si, but works satisfactorily for V_3Ga; reasons are discussed. Relations between measured properties and various metallurgical factors such as alloy compositions, cross-section reduction ratios, and heat treatment are discussed. The mechanism ...

467

Sound absorption of tropical woods and their radiation-induced composites  

International Nuclear Information System (INIS)

This is a preliminary study on the sound absorption properties of two tropical hardwoods, Light Red Meranti and Ramin, and their wood-polymer composites. Sound absorption is measured using a standing wave apparatus. The samples are of one thickness (7 mm) and cut longitudinally. Wood-polymer composites are made by impregnating the samples with methyl methacrylate which is polymerized in situ through #gamma#-irradiation. Both woods and their composites are better sound absorbers at higher sound frequencies. With partial impregnation, the absorption coefficients are improved upon particularly in the region between 1-3 kHz. (author).

1988-01-01

468

Simulation of Pulsed Neutron Activation using a CFD code  

International Nuclear Information System (INIS)

Tests for the applicability of a CFD (Computational Fluid Dynamics) code for simulating activity transport in PNA (Pulsed Neutron Activation) fluid measurements have been performed. The CFD code was combined with a Monte Carlo code used for the calculation of the initial activity distribution. The results from the calculations show that it is possible to use CFD for calculation of the activity distribution in PNA. The mainly qualitative results in this work are encouraging and suggest further work. In the continuation of this work a response function for the gamma detector will be calculated so that a PNA time spectrum can be simulated. A more accurate comparison with experimental data can then be performed

2008-09-14

469

Si-JFET devices and related noise behavior under irradiation  

Energy Technology Data Exchange (ETDEWEB)

Monolithic N-channel junction field effect transistors (NJFETs) dc characteristics, small signal parameters and noise have been studied from 300 K down to cryogenic temperatures before and after irradiation with {sup 60}Co {gamma}-rays and fast neutrons (1 MeV). Radiation induced effects on dc parameters and noise are reviewed. Noise spectral density measurements performed at various temperatures have shown that the radiation induces a noise increase which is temperature and frequency dependent. (orig.). 14 refs.

1998-02-01

470

Revisiting light neutralino scenarios in the MSSM  

CERN Document Server

We revisit the case of a light neutralino LSP in the framework of the MSSM. We consider a model with eleven free parameters. We show that all scenarios where the annihilation of light neutralinos rely mainly on the exchange of a light pseudoscalar are excluded by direct detection searches and by Fermi measurements of the gamma-flux from dwarf spheroidal galaxies. On the other hand, we find scenarios with light sleptons that satisfy all collider and astroparticle physics constraints. In this case, the lower limit on the LSP mass is 12.6 GeV. We discuss how the parameter space of the model will be further probed by new physics searches at the LHC.

2011-01-01

471

Radiological hazards in uranium mines and a yellow-cake plant in Turkey  

Energy Technology Data Exchange (ETDEWEB)

Radiological hazard in uranium mining and milling operations are primarily due to exposure to external beta and gamma radiation as well as to airborne radionuclides which consist of radon and its short-lived daughter products. In May 1981 a radiological survey programme was performed in order to make a general assessment of the radiation hazards associated with the uranium mines and the Uranium Pilot Plant operated by the M.T.A. Institute in the Koprubasi district of the Manisa province. In this paper a preliminary radiological risk evaluation attempt is presented based on the radiation and radioactivity measurements performed in this district in May 1981.

1984-06-01

472

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented. (orig.).

1985-02-01

473

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented.

1985-02-01

474

Nuclear spectroscopy, ch. 8  

International Nuclear Information System (INIS)

Energy level schemes are derived from gamma spectroscopy of several medium-mass deformed nuclei by studying the decay or proton and #alpha# nuclear spectroscopic data. Some new isomeric studies are established among which is the 31 y "1"7"8Hf isomeric state for which Isup(#pi#), K was determined to be 16"+, 16. A four quasi-particle configuration was assigned to this state at 2447.5 +- 2.5 KeV. Atomic masses have been calculated from various measurements and, on the basis of mass formulae extrapolated to neighboring mass regions.

475

Measurement of the Matrix Element for the Decay $\\eta^{\\prime} \\to \\eta \\pi^+\\pi^-$  

CERN Document Server

The Dalitz plot of $\\eta^{\\prime} \\to \\eta \\pi^+ \\pi^-$ decay is studied using $(225.2\\pm2.8)\\times 10^6$ $\\jpsi$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider. With the largest sample of $\\eta^{\\prime}$ decays to date, the parameters of the Dalitz plot are determined in a generalized and a linear representation. Also the branching fraction of $\\jpsi \\to \\gamma \\eta^{\\prime}$ is determined to be $(4.84\\pm0.03\\pm0.24)\\times 10^{-3}$, where the first error is statistical and the second systematic.

2010-01-01

476

Level structure of the doubly-odd /sup 242/Am nucleus  

Energy Technology Data Exchange (ETDEWEB)

The level structure of the doubly-odd /sup 242/Am nucleus was investigated by means of thermal-neutron-capture gamma-ray and conversion electron spectroscopy. Pair, curved-crystal, and ..beta.. spectrometers were used. The data from these measurements, combined with previous direct reaction results, permit us to establish a detailed level scheme including six new well-developed bands. Our experimental results are interpreted in the framework of the Nilsson model. Precise Gallagher-Moszkowski splittings and Newby odd-even shifts extracted from the data are compared with theoretical calculations.

1988-06-01

477

Half Life of {sup 101}Mo and {sup 101}Tc {beta}{sup -}-decay  

Science.gov (United States)

In this work, the half-lives of the beta-unstable nuclei {sup 101}Mo and {sup 101}Tc were studied using neutron-irradiated samples of {sup 100}Mo to produce {sup 101}Mo which in its turn generates {sup 101}Tc by beta decay. The gamma activity of each sample was followed for 5 consecutive half-lives in steps of 5 minutes. A total of 22 sources were measured and checked for dead-time influence, and the half-lives were obtained by weighted average. The results are statistically incompatible with the tabulated values.

2009-06-03

478

Half Life of "1"0"1Mo and "1"0"1Tc #beta#"--decay  

International Nuclear Information System (INIS)

In this work, the half-lives of the beta-unstable nuclei "1"0"1Mo and "1"0"1Tc were studied using neutron-irradiated samples of "1"0"0Mo to produce "1"0"1Mo which in its turn generates "1"0"1Tc by beta decay. The gamma activity of each sample was followed for 5 consecutive half-lives in steps of 5 minutes. A total of 22 sources were measured and checked for dead-time influence, and the half-lives were obtained by weighted average. The results are statistically incompatible with the tabulated values.

2009-06-03

479

Forward Physics with the CMS experiment at the Large Hadron Collider  

CERN Document Server

multi-parton interactions and underlying event structure, $\\gamma$-mediated processes and luminosity determination, Monte Carlo tuning and even MSSM Higgs discovery in central exclusive production. In this article, the forward detector instrumentation around the CMS interaction point is described and the prospects for diffractive and forward physics using the CMS forward detectors are summarized. In addition, first observation of forward jets as well as early measurements of the forward energy flow in the pseudorapidity range $3.15

2010-01-01

480

A new method for sealing containers with liquid samples for radioactivity measurements  

International Nuclear Information System (INIS)

It is imperative to use a leak-proof container for counting liquid sample to prevent contamination of costly gamma detectors. A sealant that ensures no leak is reported. It is a vinyl adhesive sealant used for household purposes, marketed by Gloucester Co., Inc, Franklin, MA under the trade name of Phenoseal (translucent variety). This sealant was superior to other sealants studied because it cures quickly, peels off easily after counting, and contains no detectable radioactivity. This sealant has been thoroughly tested and successfully employed it in the routine analysis of environmental liquid samples. (author)

2002-08-01

481

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average ...

1992-11-12

482

Stellar (n,#gamma#) cross sections of p-process isotopes. II. "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg  

International Nuclear Information System (INIS)

The neutron-capture cross sections of "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg have been measured by means of the activation technique. The samples were irradiated in a quasistellar neutron spectrum of kT=25 keV, which was produced at the Karlsruhe 3.7-MV Van de Graaff accelerator via the "7Li(p,n)"7Be reaction. Systematic uncertainties were investigated in repeated activations with different samples and by variation of the experimental parameters, that is, irradiation times, neutron fluxes, and #gamma#-ray counting conditions. The measured data were converted into Maxwellian-averaged cross sections at kT=30 keV, yielding 1214#+-#61, 624#+-#54, 590#+-#43, 511#+-#46, and 201#+-#11 mb for "1"6"8Yb, "1"8"0W, "1"8"4Os, "1"9"0Pt, and "1"9"6Hg, respectively. The present results either represent first experimental data ("1"6"8Yb, "1"8"4Os, and "1"9"6Hg) or could be determined with significantly reduced uncertainties ...

2010-09-01

483

Radon generation and transport in and around a gold mine tailings dam in South Africa  

Energy Technology Data Exchange (ETDEWEB)

Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the ...

2006-07-01

484

Large sample NAA facility at GRR-1 research reactor: Design and applications  

International Nuclear Information System (INIS)

Full text: A Large Sample Neutron Activation Analysis (LSNAA) facility is under development at GRR-1 research reactor, NCSR 'Demokritos'. The LSNAA facility design incorporates sample irradiation in the reactor's graphite thermal neutron column and subsequent measurement of the activity induced at a gamma spectroscopy system with gamma ray transmission measurement options included. Monte Carlo neutron and photon transport code MCNP-4C was used to model the facility. Appropriate correction factors accounting for neutron field perturbation during sample irradiation, high purity germanium detector efficiency for the volume source and gamma ray self-absorption within the sample itself were derived. The results of the computations were experimentally verified by activation foil measurements for a set of known materials and a range of sample sizes extending up to 10 ...

2003-06-09

485

Isobaric analog resonances in "8"9Y  

International Nuclear Information System (INIS)

Three resonances at the proton energies 7.0, 7.08, and 7.53 MeV on the target "8"8Sr were chosen to investigate the possibility of determining the amplitudes of the weak coupling experimentally. The corresponding "8"9Sr levels under investigation were 1.93 MeV ("5/_2"+), 2.00 MeV ("3/_2"+), and 2.46 MeV ("3/_2"+). Angular distributions were measured on resonance at 7.0, 7.08, and 7.53 MeV from proton inelastic scattering to the 1.84 MeV (2"+) state of "8"8Sr for differential cross section, analyzing power, spin-flip probability, and spin-flip asymmetry. A polarized beam of protons was used to obtain the analyzing power. The spin-flip probability was obtained from the coincidence of the prompt gamma rays from the (p,p'#gamma#) reaction with the scattered protons. With the polarized beam, the gamma coincidence technique was further used to obtain a spin-flip asymmetry measurement. ...

488

Is there still a place for bone scanning in Ewing's sarcoma: concise communication  

International Nuclear Information System (INIS)

In this retrospective study, 28 cases of Ewing's sarcoma are reviewed for the onset of metastasis. Bone scans demonstrated bone metastasis in three out of 28 patients at presentation. Of the 22 patients free of metastases at presentation, ten subsequently developed bone metastases. In six of these patients, the bone scan was the earliest demonstrator of metastatic disease. Bone scans are recommended at presentation and periodically during follow-up.

491

Ectopic Ureter  

Science.gov (United States)

... such as renal flow scan or a formal kidney X-ray, called an intravenous pyelogram ( IVP ), may help ...

498

Uranium isotopic assay instrument  

International Nuclear Information System (INIS)

Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic ...

2006-10-16