WorldWideScience
1

None - TDGLOBAL - NASA  

Science.gov (United States)

vibration Isolation system for the camera. ... to further define the response of the camera vibration isolation system. These ...

2

Hybrid Camera Surveillance System Using Robust Human Detection  

Science.gov (United States)

We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.

2007-01-01

3

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The ...

2007-03-15

4

Real-time neutron radiography at the Iea-R1 m nuclear research reactor  

International Nuclear Information System (INIS)

A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, ...

2003-06-01

5

Thyroidal uptake of iodine-123 in children using a gamma camera and computer  

Energy Technology Data Exchange (ETDEWEB)

The measurement of thyroidal uptake of radioiodine using a gamma camera and computer is described. In 12 children there was good agreement with simultaneous measurements using a probe, while in a further 14 patients the uptake values were consistent with the clinical diagnosis. The technique should be especially useful for infants and small children.

1985-10-01

6

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

7

FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...  

Science.gov (United States)

was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...

8

A unified framework for capturing facial images in video surveillance systems using cooperative camera system  

Science.gov (United States)

Low resolution and un-sharp facial images are always captured from surveillance videos because of long human-camera distance and human movements. Previous works addressed this problem by using an active camera to capture close-up facial images without considering human movements and mechanical delays of the active camera. In this paper, we proposed a unified framework to capture facial images in video surveillance systems by using one static and active camera in a cooperative manner. Human faces are first located by a skin-color based real-time face detection algorithm. A stereo camera model is also employed to approximate human face location and his/her velocity with respect to the active camera. Given the mechanical delays of the active camera, the position of a target face with a given delay can be estimated using a ...

2008-04-01

9

Search for TeV Counterparts in $\\gamma$-Ray Bursts  

CERN Document Server

Based on BACODINE network notification the Whipple Observatory gamma-ray telescope has been used to search for the delayed TeV counterpart to BATSE-detected gamma-ray bursts. In the fast slew mode, any point in the sky can be reached within two minutes of the burst notification. The search strategy, necessary because of the uncertainty in burst position and limited FOV of the camera, is described.

1997-01-01

10

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is ...

2001-07-01

11

Camera position estimation and feature extraction from an incomplete image of a landmark  

British Library Electronic Table of Contents (United Kingdom)

In the autonomous unmanned helicopter landing problem, the position of the unmanned helicopter relative to the landmark is very important. A camera carried on the unmanned helicopter can capture an image of the landmark. In earlier research, it was reported that the camera position could be estimated by features extracted from the landmark image. However, it is necessary that the landmark image should be complete, or with only slight deficiencies, in order for this estimation process to be possible. In this article, we report on an innovative design for an estimation made from a camera position giving an incomplete single image of the landmark. An adaptive neuro-fuzzy inference system (ANFIS) is used to construct the mapping relation between the features of complete and incomplete landmark...

2011-01-01

12

Real-time neutron radiography at Texas A and M University  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide ...

1990-12-20

13

Real-time neutron radiography at Texas A and M University  

International Nuclear Information System (INIS)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide ...

1990-12-01

14

GaP Project: #gamma#p, #gamma#e, #gamma##gamma# colliders physical programs and CompHEP computer system  

International Nuclear Information System (INIS)

The Gamma Physics (GaP) program of physical phenomena investigation is proposed on #gamma#p, #gamma#e and #gamma##gamma# colliders at TeV energies. The program contains specialized software (CompHEP system) created for automation of particle interaction processes calculations in the framework of various gauge models. Preliminary physical results are presented (heavy quark production, W, Z production, supersymmetry etc.), and further software development is suggested. (R.P.) 22 refs., 8 figs., 4 tabs.

15

Preliminary Fabry Perot testing - 1986  

Science.gov (United States)

Fabry Perot interferometry is a method of determining instantaneous velocities of an object in motion. The interferometer system is composed of the Fabry Perot interferometer, a laser, an electronic streak camera, and several focusing lenses. The first tests discussed were done on exploding bridgewire devices. During these tests, several system parameters were changed. These changes did not seem to affect the data, which appeared to be consistent. The second tests performed focused on slapper-type devices. It was determined that sandblasted, vapor-deposited aluminum on the slapper material would be required to yield quality data. Streak camera failure prevented much data from being collected. An effort is being made to replace the current streak camera. After it is replaced, a Fabry Perot and velocity interferometry system for any reflector comparison will be ...

1987-04-30

16

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light ...

2000-07-01

17

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video ...

2000-01-01

18

Wildlife Monitoring Program Plan - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Wildlife Monitoring System Schematic .......................... 40 ...... sentinel species - healthy fish are placed in an environment of water (where they arc not .... The way ir! which data for the fnre mdor study groups will be gathered tor managciacilt ...... Earth Resources Aircraft Program (ERAP) Camera ...

19

Phantom simulation device for scintillation cameras  

Energy Technology Data Exchange (ETDEWEB)

A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.

1981-08-25

20

Inguino-scrotal hernia detection in the early phase of a bone scan  

International Nuclear Information System (INIS)

A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd

1999-11-01

21

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

22

Attention deficit hyperactivity disorder: binding of [{sup 99m}Tc]TRODAT-1 to the dopamine transporter before and after methylphenidate treatment  

Energy Technology Data Exchange (ETDEWEB)

Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gamma camera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with ...

2000-10-01

23

Versatile gamma scanning system  

International Nuclear Information System (INIS)

(Feb 1972). United States Swinth, KL Weber, JW San Francisco, Calif.

24

Measurements of nuclear emulsion tracks by means of a picture analysis system  

Energy Technology Data Exchange (ETDEWEB)

A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.

1986-01-01

25

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.

1986-01-15

26

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).

1986-01-01

29

Research on Dynamic Neutron Radiography in HANARO  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for ...

2005-07-01

30

Research on Dynamic Neutron Radiography in HANARO  

International Nuclear Information System (INIS)

Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for ...

2005-10-27

31

High intensity lasers for gamma-gamma colliders  

International Nuclear Information System (INIS)

Compton backscattering of laser photons near the interaction point of an e"+e"- or e"-e"- collider can be used to produce a #gamma#-#gamma# or #gamma#-e"- collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e"+e"- colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).

32

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

33

Technique for compressing light intensity ranges utilizing a specifically designed liquid crystal notch filter  

Energy Technology Data Exchange (ETDEWEB)

A pin hole camera assembly for use in viewing an object having a relatively large light intensity range, for example a crucible containing molten metal in an atomic vapor laser isotope separation (AVLIS) system is disclosed herein. The assembly includes means for optically compressing the light intensity range appearing at its input sufficient to make it receivable and decipherable by a standard video camera. To accomplish this, the assembly utilizes the combination of interference filter and a liquid crystal notch filter. The latter which preferably includes a cholesteric liquid crystal arrangement is configured to pass light at all wavelengths, except a relatively narrow wavelength band which defines the filter's notch, and includes means for causing the notch to vary to at least a limited extent with the intensity of light at its light incidence surface.

1988-01-01

34

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

35

Numerical simulation and experiment research of radiation performance in a dish solar collector system  

British Library Electronic Table of Contents (United Kingdom)

The Monte Carlo ray-tracing method is applied and coupled with optical properties to predict the radiation performance of solar concentrator/cavity receiver systems. Several different cavity geometries are compared on the radiation performance. A flux density distribution measurement system for dish parabolic concentrators is developed. The contours of the flux distribution for target placements at different distances from the dish vertex of a solar concentrator are taken by using an indirect method with a Lambert and a charge coupled device (CCD) camera. Further, the measured flux distributions are compared with a Monte Carlo-predicted distribution. The results can be a valuable reference for the design and assemblage of the solar collector system.

2010-01-01

36

Nuclear fuel assembly identification using computer vision  

Science.gov (United States)

This report describes an improved method of remotely identifying irradiated nuclear fuel assemblies. The method uses existing in-cell TV cameras to input an image of the notch-coded top of the fuel assemblies into a computer vision system, which then produces the identifying number for that assembly. This system replaces systems that use either a mechanical mechanism to feel the notches or use human operators to locate notches visually. The system was developed for identifying fuel assemblies from the Fast Flux Test Facility (FFTF) and the Clinch River Breeder Reactor, but could be used for other reactor assembly identification, as appropriate.

1985-11-01

37

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor  

International Nuclear Information System (INIS)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-01

38

Artificial intelligence: the future in nuclear plant maintenance  

Energy Technology Data Exchange (ETDEWEB)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-12-01

39

Artificial intelligence: the future in nuclear plant maintenance  

International Nuclear Information System (INIS)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-09-23

40

Application of remote sensing for coal waste embankment monitoring  

Energy Technology Data Exchange (ETDEWEB)

The Bureau of Mines has two projects in the remote sensing field as it pertains to mining. One of these is a completed contract that studied the use of aircraft mounted cameras and the results of photogrammetry. The second project is an ongoing contract to study the effectiveness of using an instrumentation system wired to remote data collection station to record embankment data. 6 refs.

1981-01-01

41

AERONAUTICAL ENGINEERING - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Topics addressed include future trends in IR sensors, IR observer performance modeling ... steer a sensor platform with a thermal camera or an air-to-air missile system. .... Skyship and Sentinel series airships. It also outlines the current .... A layout schematic of the UPS is given. AIAA. A93-55494 ...

42

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

43

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

44

The centers of early-type galaxies with HST; 2, empirical models and structural parameters  

CERN Document Server

We present a set of structural parameters for the central parts of 57 early-type galaxies observed with the Planetary Camera of the Hubble Space Telescope. These parameters are based on a new empirical law that successfully characterizes the centers of early type galaxies. This empirical law assumes that the surface brightness profile is a combination of two power laws with different slopes gamma and beta for the inner and outer regions. Conventional structural parameters such as core radius and central surface brightness are replaced by break radius r_b, where the transition between power-law slopes takes place, and surface brightness mu_b at that radius. An additional parameter alpha describes the sharpness of the break. The structural parameters are derived using a chi-squared minimization process applied to the mean surface brightness profiles. The resulting model profiles generally give very good agreement to the observed profiles out to ...

1996-01-01

45

Measurement of the branching fractions for $J/\\psi\\to\\gamma\\pi^0$, $\\gamma\\eta$ and $\\gamma\\eta^{\\prime}$  

CERN Document Server

The decay modes $\\jpsi\\ar\\gamma\\pi^0, \\gamma\\eta$ and $\\gamma\\etap$ are analyzed using a data sample of 58 million $\\jpsi$ decays collected with the BESII detector at BEPC. The branching fractions are determined to be: $Br(\\jpsi\\ar\\gamma\\pi^0)=(3.13^{+0.65}_{-0.44})\\times10^{-5}$, $Br(\\jpsi\\ar\\gamma\\eta)=(11.23\\pm0.89)\\times10^{-4}$, and $Br(\\jpsi\\ar\\gamma\\etap)=(5.55\\pm0.44)\\times10^{-3}$, where the errors are combined statistical and systematic errors. The ratio of partial widths $\\Gamma(\\jpsi\\ar\\gamma\\etap)/\\Gamma(\\jpsi\\ar\\gamma\\eta)$ is measured to be $4.94\\pm0.40$, and the singlet-octet pseudoscalar mixing angle of $\\eta-\\etap$ system is determined to be $\\theta_{P}=(-22.08\\pm0.81)^{\\circ}$.

2006-01-01

46

Grate monitoring systems, state of the art; Metoder foer rosteroevervakning, dagslaegesbestaemning  

Energy Technology Data Exchange (ETDEWEB)

During a number of years research and development projects have been made to present methods of monitoring the grate in a grate fired boiler. The monitoring is interesting in order to be able to increase efficiency, increase burn-out of ash, improve the status of emissions, improve transportation of ash and fuel through the furnace, reduce costs for operation and maintenance, handle greater loads etc. Improvement of the combustion has been concentrated to the development of the gas phase combustion. In the past few years the computer development has progressed rapidly and the use of optical monitoring methods have been made possible for monitoring grates. To analyse state of the art of optical grate monitoring systems three different methods have been used, literature search, inquiry where plant owners were asked if they have used grate monitoring systems and if so what experiences they have, and interviews with scientists and users. The ...

2001-01-01

47

On-line video image processing system for real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) ...

1983-09-15

48

An on-line video image processing system for real-time neutron radiography  

International Nuclear Information System (INIS)

The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) ...

1983-09-01

50

Albedo method applied to coupled neutron-gamma shielding radiations; Metodo do Albedo aplicado a blindagem de radiacoes neutron-gama acoplados  

Energy Technology Data Exchange (ETDEWEB)

The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)

2000-07-01

51

Albedo method applied to coupled neutron-gamma shielding radiations  

International Nuclear Information System (INIS)

The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)

2000-10-15

52

Application of neutron radiography to a diagnosis of refrigerator  

International Nuclear Information System (INIS)

A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).

1996-07-01

53

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material.

2000-03-01

54

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

International Nuclear Information System (INIS)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material

2000-03-01

55

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-08-01

56

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose ...

1994-01-01

57

Neutron radiography with the cyclotron, 4  

International Nuclear Information System (INIS)

A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented ...

1986-01-01

58

Design of a new serotonin receptor 5-HT_1_A imaging agent based on "9"9"mTc  

International Nuclear Information System (INIS)

Serotonin is one of the neurotransmitters found in the brain and mediates brain functions. It is very well known that serotonin related brain abnormalities are exerted mainly via serotonin receptors in a similar manner to other neurotransmitters found in the brain. Recently, it has also been found that serotonin is involved in Alzheimer's disease either directly or indirectly by its actions on serotonergic neurons. To understand and treat the diseases caused by abnormalities in the serotonergic system in the brain, it is certain that its mechanism of function has to be well investigated. So far several 5-HT receptors and receptor subtypes have been well characterized. Moreover, serotonin agonists and antagonists acting on specific receptors are chemically synthesized and are now available for the prevention or treatment of serotonergic related diseases. In recent years, a great demand for developing neuroimaging agents has emerged for the diagnosis of abnormal ...

2004-07-01

60

IMEF gamma scanning system  

International Nuclear Information System (INIS)

The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

1989-09-10

61

Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.

62

Calibration of Initial Measurements from the Full Aperture Backscatter system on NIF  

Energy Technology Data Exchange (ETDEWEB)

The Full Aperture Backscatter System (FABS) provides a measure of the spectral power, and integrated energy scattered by stimulated Brillouin (348-354 nm) and Raman (400 - 700 nm) scattering into the final focusing lens of the first four beams of the NIF laser. The system was designed to provide measurements at the highest expected fluences with: (1) spectral and temporal resolution, (2) beam aperture averaging, and (3) near-field imaging. This is accomplished with a strongly attenuating diffusive fiber coupler and streaked spectrometer and separate calibrated time integrated spectrometers, and imaging cameras. Measurement of the wavelength dependent sensitivity of the complete system is accomplished with a calibrated Xe lamp. Data from the calibration system is combined with experimental data to produce the power and energy measurements. Examples of measurements will be discussed.

2004-04-01

63

Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging  

Energy Technology Data Exchange (ETDEWEB)

{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space ...

2006-01-15

64

New approach for in vivo detection of insulitis in type I diabetes: activated lymphocyte targeting with "1"2"3I-labelled interleukin 2  

International Nuclear Information System (INIS)

Insulitis is considered the histopathological hallmark of type I diabetes. In the non-obese diabetic (NOD) mouse, diabetes has never been observed in the absence of insulitis. The in vivo detection of insulitis could be of relevance for early prediction of diabetes. As approximately 15% of islet-infiltrating lymphocytes express interleukin 2 receptors, the authors have labelled recombinant inter-leukin 2 with "1"2"3I and used this radiopharmaceutical to detect insulitis by gamma camera imaging. The authors studied 71 prediabetic NOD and 27 normal Balb/c mice. Labelled #alpha#-lactalbumin was used as the control protein. In the first set of experiments the tissue distribution of radiolabelled interleukin 2 in isolated organs from animals sacrificed at different time points was studied. Higher radioactivity was detected in the pancreas of NOD mice injected with labelled interleukin 2, as compared to NOD mice receiving labelled ...

1994-01-01

65

Three-frame Algorithm of Car Path Reconstruction from Airborne Traffic Data  

CERN Document Server

The airborne traffic monitoring system forms a novel technology of detecting vehicle motion. An optical digital camera located on an airborne platform produces a series of images which then are processed to recognized the fixed vehicles. In this way the video data are converted into the time sequence of frames containing the vehicle coordinates. In the present work a three-frame algorithm is developed to identify the succeeding vehicle positions. It is based on finding the neighboring points in the frame sequence characterized by minimal acceleration. To verify and optimize the developed algorithm a ``Virtual Road'' simulator was created. Finally available empirical data are analyzed using the created algorithm.

2007-01-01

66

PLZT electrooptic shutters: applications  

Science.gov (United States)

Advances in the development of several electrooptic shutter devices utilizing the quadratic electrooptic effect of lead lanthanum zirconate titanate (PLZT) ceramic wafers are described. Aperture sizes utilized in these PLZT devices ranged from 25 ..mu..m to 0.25 m. Practical applications of the shutters discussed in this paper include eye protection in military and industrial applications, a goggle-type device with dual synchronously operated PLZT shutters for use in a stereoscopic three-dimensional TV display, an electrically controlled variable density filter for use with vidicon tubes, a large-aperture photographic shutter for image motion compensation cameras, and a page composer for use in a holographic memory system.

1975-08-01

67

Neutron radiography with the cyclotron, 5  

International Nuclear Information System (INIS)

Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).

1987-01-01

68

Laser ray-tracing method for optical testing.  

Science.gov (United States)

We have developed a novel laser ray-tracing method to measure aberrations in optical systems. It consists of delivering narrow laser pencils (by a laser scanner), recording the spots that are formed on the image plane (with a CCD camera), and computing the position of each centroid. This approach could be considered an experimental (approximate) implementation of standard numerical ray tracing. Several tests and experiments, including a direct comparison with a Hartmann-Shack wave-front sensor, provided highly satisfactory results that confirmed the validity of the method and revealed potential advantages. PMID:18073906

1999-07-15

69

W, Z and H bosons in the three particle final states production at TeV energy #gamma#e and #gamma##gamma#colliders  

International Nuclear Information System (INIS)

The short review of complete tree level calculations for three particle final states production at the future e"+e"-, #gamma#e and #gamma##gamma# colliders is presented. The results obtained with the help of CompHEP system for total cross sections and other characteristics of processes in the energy range 0.1-2 TeV are summarized and their comparison with the results of different approaches is discussed. In particular we are interested in the processes of W, Z and H boson production. The reactions under consideration are especially interesting in connection with probing of new couplings, searching for new particle signals and as an important backgrounds to these experiments. The main subjects described are basic reactions rates (sections 2,3), Higgs production in #gamma#e collisions (section 4), the possibilities of testing some four vector bosons interaction vertices and Higgs-fermion coupling (section ...

1993-12-01

70

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized ...

1983-11-01

71

Neutron imaging system for neutron tomography, radiography, and beam diagnostics  

Energy Technology Data Exchange (ETDEWEB)

A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.

1995-12-31

72

Implantation of an electronic system for real time neutron graphic images acquisition at the IPEN/CNEN Argonaut reactor; Implantacao de um sistema eletronico para aquisicao de imagens neutrongraficas em tempo real no reator Argonauta do IEN/CNEN  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)

2004-04-15

74

Two-phase flow regime observations in a vertical hexagonal flow channel with and without a finned fuel bundle  

International Nuclear Information System (INIS)

Previous flow regime studies have been for horizontal, vertical, and inclined pipe flow. As such, only a few studies have been performed on bundle geometries. The present paper examines the flow regimes for a vertical hexagonal flow channel with and without a finned fuel bundle. This type of a 36 finned rod hexagonal fuel bundle in parallel hexagonal flow channels is used in a MAPLE (Multi- purpose Applied Physics Lattice Experimental) type nuclear reactor. An experiment apparatus was designed consisting of the flow channel, inlet plenum and an air-water separator. The inlet plenum is used to provide a uniform mixture of air and water before entering the hexagonal flow channel. A turbine flow meter is used to determine the water flow rate. The turbine flow meter is calibrated for a low flow range and limits the measurable flow to 50 l/min. Flow pattern observation is determined by a SONY video camera, Real-Time Neutron Radiography, pressure transducer and ...

1990-12-10

75

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport ...

2009-12-01

76

3-Dimensional Mapping of Corneal Topography and Thickness  

CERN Document Server

Optical sections of the cornea are obtained by illumination with a collimated beam expanded in a fan shape by a small rotary cylindrical lens. The light diffused from the cornea is observed by two cameras and processed in order to yield the surfaces' profiles. The optical system used to project a thin rotating line on the cornea consists of a white light source provided with optical fiber bundle output which is first conditioned by a set of lenses so that it would produce a spot on the cornea. A small cylinder lens is used to expand the beam in one direction so that a thin line illuminates the cornea, rather than a spot. The cylinder lens is provided with motor driven rotation about an axis normal to its own in order to rotate the line on the cornea such that the projected line scans the whole cornea; the illuminator is completed with a slit aperture. The cornea is not perfectly transparent, scattering some of the light that traverses it; this ...

2003-01-01

77

Real-time imaging for neutron radiography at KURRI  

International Nuclear Information System (INIS)

For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).

1987-07-01

78

A Multi-Layered Image Cache for Scientific Visualization  

Energy Technology Data Exchange (ETDEWEB)

We introduce a multi-layered image cache system that is designed to work with a pool of rendering engines to facilitate an interactive, frameless, asynchronous rendering environment. Our system decouples the rendering from the display of imagery. Therefore, it decouples render frequency and resolution from display frequency and resolution, and allows asynchronous transmission of imagery instead of the compute/send cycle of standard parallel systems. It also allows local, incremental refinement of imagery without requiring all imagery to be re-rendered. Images are placed in fixed position in camera (vs. world) space to eliminate occlusion artifacts. Display quality is improved by increasing the number of images. Interactivity is improved by decreasing the number of images.

2003-06-26

79

Development of ARIES Baker-Nunn camera to a wide-field Imaging Telescope with CCD  

CERN Document Server

ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.

2009-01-01

80

Gamma scanning of FBTR fuel pins  

International Nuclear Information System (INIS)

This paper presents the results obtained in the gamma scanning of two fuel pins from the bent subassembly of the fast breeder test reactor (FBTR) using a segmented gamma scanning system employing segment correlation developed for the assay of glove box solid waste. In addition to the actinide profiles, the paper also discusses the fission products and clad activation product profiles and tries to correlate the experimental values of the latter with computed values. (author). 4 refs., 1 fig., 1 tab.

84

High intensity lasers for gamma-gamma colliders  

Energy Technology Data Exchange (ETDEWEB)

Compton backscattering of laser photons near the interaction point of an e{sup +}e{sup -} or e{sup -}e{sup -} collider can be used to produce a {gamma}-{gamma} or {gamma}-e{sup -} collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e{sup +}e{sup -} colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).

1995-02-01

85

Gamma ray observations of the solar system  

Energy Technology Data Exchange (ETDEWEB)

Two general categories are discussed concerning the evolution of the solar system: the dualistic view, the planetesimal approach and the monistic view, the nebular hypothesis. The major points of each view are given and the models that are developed from these views are described. Possible applications of gamma ray astronomical observations to the question of the dynamic evolution of the solar system are discussed.

1981-01-01

86

Development and application of a gamma scanning system for LLW and MLW packages  

International Nuclear Information System (INIS)

The report describes the studies carried out to design a non-destructive system for the radiological characterization of packages containing LLW and MLW. This technique is applied for quantitative and qualitative gamma emitters determination in packages with homogeneous and heterogeneous matrices as well as the development of a maximum activity points location system. Development involves also the automatization for its industrial use.

1993-09-05

87

A coincidence long baseline celestial gamma-ray burst detection system  

International Nuclear Information System (INIS)

A time coincidence long baseline (250 km) cosmic ray detection system has been developed to search for bursts of high energy #gamma#-rays (E_0>= 10"1"3 eV) of extra-terrestrial origin. The system design incorporates the possibility of simultaneous observation over a variety of time scales between 1 #mu#s and 10 s. (Auth.).

90

A comparison of the X-ray properties of X Per and gamma Cas  

Energy Technology Data Exchange (ETDEWEB)

The X-ray properties of the main sequence Be stars conclude that they are a widely separated binary system containing an accreting neutron star.

1982-04-01

91

Higgs, SUSY and the standard model at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

In this report, I surveyed physics potential of the {gamma}{gamma} option of a linear e{sup +}e{sup -} collider with the following questions in mind: What new discovery can be expected at a {gamma}{gamma} collider in addition to what will be learned at its 'parent' e{sup +}e{sup -} linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e{sup -} beams, we find that a {gamma}{gamma} collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e{sup -}e{sup -} system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a {gamma}{gamma} ...

2001-10-11

92

Higgs, SUSY and the standard model at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

In this report, I surveyed physics potential of the #gamma##gamma# option of a linear e"+e"- collider with the following questions in mind: What new discovery can be expected at a #gamma##gamma# collider in addition to what will be learned at its 'parent' e"+e"- linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e"- beams, we find that a #gamma##gamma# collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e"-e"- system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a #gamma##gamma# collider. CP property of the scalar sector can be ...

2001-10-11

93

Determination of distal dose edge location by measuring right-angled prompt-gamma rays from a 38 MeV proton beam  

International Nuclear Information System (INIS)

In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas ...

2007-09-21

94

Spray, combustion, and heat transfer studies in a Ricardo hydra direct-injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

The spray and combustion development in a single-cylinder, direct-injection diesel engine equipped with optical access was examined using a number of complementary techniques. A laser imaging system, based around a pulsed copper-vapour laser synchronised to an intensified CCD camera, was used to obtain images of the four fuel sprays prior to combustion, and to determine the tip penetration of each spray as a function of crankangle. The surface heat flux to the wall of the piston bowl was measured by placing a fast-response thermocouple at the impingement point of one of the sprays, and a two-colour imaging system was used to obtain digital images of the flame temperature and equivalent soot distribution in the cylinder. (author)

1996-12-31

95

Recursive neural networks for processing graphs with labelled edges: theory and applications.  

Science.gov (United States)

In this paper, we introduce a new recursive neural network model able to process directed acyclic graphs with labelled edges. The model uses a state transition function which considers the edge labels and is independent both from the number and the order of the children of each node. The computational capabilities of the new recursive architecture are assessed. Moreover, in order to test the proposed architecture on a practical challenging application, the problem of object detection in images is also addressed. In fact, the localization of target objects is a preliminary step in any recognition system. The proposed technique is general and can be applied in different detection systems, since it does not exploit any a priori knowledge on the particular problem. Some experiments on face detection, carried out on scenes acquired by an indoor camera, are reported, showing very promising results. PMID:16181770

2005-09-21

96

Neutron radiography with the cyclotron, 5. Cyclotron-based real time neutron fluoroscopy system and its application for some industrial components  

Energy Technology Data Exchange (ETDEWEB)

Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.

1987-03-01

97

Infrared monitoring of the Doublet III beam armor plate  

Energy Technology Data Exchange (ETDEWEB)

An 80 keV, 3.6 MW neutral beam injection system has recently been installed on Doublet III, and the installation of a second system is scheduled within several months. Armor plate consisting of /approximately equals/100 graphite tiles (10 cm x 10 cm) coated with TiC has been plated over portions of the inner vacuum wall lying in the line of sight of the ion sources. In order to monitor the condition of the armor plate an infrared camera and a set of optical pyrometers have been installed alongside the beamline and view the armor plate through a CaF/sub 2/ window. The pyrometers measure the temperature of the armor plate associated with the maximum of the intensity distribution of each ion source.

1981-01-01

98

Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system  

Energy Technology Data Exchange (ETDEWEB)

The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide ...

2003-05-01

100

Moessbauer spectroscopy study of iron corrosion underneath painting system  

International Nuclear Information System (INIS)

The effect of pigments on the development of corrosion products between the painting system and metal surface when exposed to marine environments has been discussed. The pigments studied were: red mud zinc chromate, zinc chromate, red oxide zinc phosphate, manganese phosphate barium chromate and basic lead silico chromate. Moessbauer spectroscopy revealed that the upper rust layer in all the cases consisted of #gamma#-Fe_2O_3, #gamma#-FeOOH and #alpha#-FeOOH. The lower rust layer immediately in contact with the metal surface consisted of an asymmetrical doublet due to #gamma#-FeOOH. (Auth.).

101

The uterine blush. A potential false-positive in Meckel's scan interpretation  

Energy Technology Data Exchange (ETDEWEB)

To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative ...

1982-10-01

102

Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of [sup 99m]Tc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain ...

1993-10-01

103

Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of "9"9"mTc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain on ...

104

Quantitative bone scintigraphy in patients with osteoporosis  

International Nuclear Information System (INIS)

Quantitative bone scans were evaluated in 16 patients with osteoporosis and in a control group of 7 healthy subjects. Along with a detailed biochemical analysis of calcium-phosphorus metabolism and standartized reongenographs, a quantitative dynamic bone scintigraphy was performed according to the method proposed by the authors. The bone-accumulating factor K_b was determined on the base of mathematical analysis of the graph reflecting activity changes in bone tissue unit during the investigation, the blood-elimination factor K_h and kidney-elimination factor K_k. In addition the accumulation index AI (in %) was calculated as a relation between the activity in bone tissue unit, registered in 20 min interval, and the activity in soft tissues for the same time. Whereas the static gamma camera scintigraphy, made 3-4 hrs after injecting of the osteotrope radiopharmaceuticals, showed no specific changes in the patients examined, the method proposed ...

105

Quantitative bone scintigraphy and 24-hour whole-body counting of [sup 99m]Tc-methylene diphosphonate in patients with prostatic carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of [sup 99m]Tc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal ...

1992-10-01

106

Quantitative bone scintigraphy and 24-hour whole-body counting of "9"9"mTc-methylene diphosphonate in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of "9"9"mTc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal metastases. (orig.).

107

Quantitative assessment of bone scintigraphy in the hip joint disease  

International Nuclear Information System (INIS)

Quantitative assessment of bone scintigraphy was performed in fifty-six patients with hip joint disease including femoral neck fracture, aseptic necrosis of the femoral head, traumatic dislocation of the hip, Perthes disease, and transient synovitis of the hip. In the static study, bone scintigraphy was obtained 3 hours after injection of sup(99m)Tc-MDP by gamma camera equipped with a computer and uptake ratios were calculated. In the dynamic study, bone scintigraphy was performed in one, 3 and 5 hours after injection of radionuclide. Femoral head uptake ratio was markedly decreased in osteonecrosis following femoral neck fracture and characteristically increased in aseptic necrosis of the femoral head but prolonged retention of sup(99m)Tc-MDP could be observed. Uptake ratios of epiphysis were decreased in Perthes disease but normal in transient synovitis of the hip. Static and dynamic study of bone scintigraphy may be useful for early ...

108

Imaging of dialysis-related amyloid (AB-amyloid) deposits with sup 131 I-beta 2-microglobulin  

Energy Technology Data Exchange (ETDEWEB)

The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled beta 2-microglobulin is taken up by the ...

1990-12-01

109

Bone scintigraphy in fluoride treated osteoporosis  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. ...

1985-05-01

110

A finite element study of gamma ray transport  

Energy Technology Data Exchange (ETDEWEB)

A complete code based on the finite element method (FEM) is used to study the attenuation of gamma rays, of source energy 9 MeV, in simple homogeneous lead and water systems. The results are compared, in tables and graphs, with those produced by a Monte Carlo method of solution. In the comparison, particular attention is paid to the annihilation gamma rays generated by the pair production process, to energy deposition, and to the leakage spectra. A model, multilayer, slab shield, having a fission neutron source impinging on the left-hand face, is also solved by the FEM code, using data from a coupled neutron/gamma ray cross section library. The resulting neutron and gamma ray flux distributions, and the leakage spectra, are shown graphically. (author).

1990-01-01

111

Computer analysis and control for nondestructive gamma scanning of LMFBR fuel pins  

International Nuclear Information System (INIS)

A program to modernize existing computer control and data analysis in a precision gamma-scanning system is described. This involves interfacing a new computer-based multichannel analyzer to existing equipment through a CAMAC system with an intelligent crate controller and writing software for scan control and data reduction. Both hardware and software requirements are discussed. 6 figures.

112

MTF analysis of the MURR real-time neutron radiography facility  

International Nuclear Information System (INIS)

In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used ...

1982-04-01

113

CleverFarm - A SuperSCADA system for wind farms  

Energy Technology Data Exchange (ETDEWEB)

The CleverFarm project started out to build an integrated monitoring system for wind farms, where all information would be available and could be used across the wind farm for maintenance and component health assessments. This would enable wind farm operators to prioritise their efforts, since they have a good view of the farm status from home. A large emphasis was placed on the integration of condition monitoring approaches in the central system, enabling estimates of the remaining lifetime of components, especially in the nacelle. During the 3,5 years of the project, software and hardware was developed and installed in two wind farms in Denmark and Germany. The connected hardware included two different condition monitoring systems based on vibration sensors from Gram&Juhl and ISET, plus a camera system developed by Overspeed. Additionally, short-term predictions of the ...

2004-08-01

114

Activation cross sections of deuteron-induced nuclear reactions on hafnium  

International Nuclear Information System (INIS)

Experimental excitation functions for deuteron-induced reactions up to 20 MeV on high purity natural hafnium were measured with the activation method using a stacked foil irradiation technique. Metallic hafnium foils with thickness of 10 #mu#m were stacked together with 50 #mu#m thick aluminium and 12 #mu#m thick titanium foils. The aluminium foils served as energy absorber while the titanium foils were used to monitor the energy and intensity of the bombarding deuteron beam. From a detailed remeasurement of the complete excitation function of the "n"a"tTi(d,x)"4"8V monitor reaction it was possible to adopt the proper incident energy and beam intensity by comparing the results with the recommended values. High resolution off-line gamma-ray spectrometry was applied to assess the activity of each foil. From the measured activity independent and/or cumulative elemental or isotopic cross section data for production of Ta, Hf and Lu radioisotopes by (d,x) reactions were ...

2010-11-15

115

Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring  

International Nuclear Information System (INIS)

A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of ...

116

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the ...

117

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the ...

2007-03-15

118

DNA alterations detected in the progeny of paternally irradiated Japanese medaka fish (Oryzias latipes).  

UK PubMed Central (United Kingdom)

A nonmammalian test system for germ-cell mutagenesis has been developed by using the Japanese medaka fish. We describe a system for detecting DNA alterations in F1 progeny descended from the gamma-irradiated...Full Text Available

1995-01-03

119

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing excitation/detection ...

1993-12-01

120

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

121

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

122

Mismatch measurement and correction tools for the PS-SPS transfer of the 26GeV/C LHC beam  

CERN Document Server

TRANSVERSE EMITTANCE PRESERVATION IS A MAJOR CONCERN OF THE LHC INJECTOR CHAIN. MINIMISATION OF THE BLOW-UP DUE TO MISMATCH AT INJECTION INTO THE SPS IS THEREFORE MANDATORY. WHILE THE TRANSVERSE POSITIONN OF THE BEAM IN THE SPS INJECTION LINE IS MONITORED BUNCH BY BUNCH BY AN OTR (OPTICAL TRANSITION RADIATION) SCREEN AND A FAST CCD (CHARGED COUPLED DEVICE) CAMERA, THE PHASE SPACE MATCHING AT INJECTION IS MONITORED BY AN OTR BASED MISMATCH MONITOR IN THE SPS RING. ORTHOGONAL TUNING KNOBS WERE DEVELOPED TO TUNE INDEPENDENTLY TWISS PARAMETERS, DISPERSION AND DISPERSION DERIVATIVE. IN THIS PAPER WE DESCRIBE THE MISMATCH CORRECTION MECHANISM AS WELL AS THE TWO MONITORING SYSTEMS. WE REPORT ON FIRST MEASUREMENTS WHICH WERE CARRIED OUT DURING THE 1998 SPS RUN.

1999-01-01

123

Flame propagation characteristics and flame structures of zirconium particle cloud in a small-scale chamber  

British Library Electronic Table of Contents (United Kingdom)

Flame propagating through zirconium particle cloud in a small-scale vertical rectangle chamber was investigated experimentally. In the experiments, the zirconium quoted 99% purity was used and the diameter of particles was distributed 1?22 ?m. The zirconium dust was dispersed into the chamber by air flow and ignited by an electrode spark. A high-speed video camera was used to record the images of the propagating flame. Micro-thermocouples, schlieren optical system and microscopic lens were used to obtain temperature profiles and flame structure, respectively. Based on the experimental results, flame propagation characteristics and flame structure of zirconium particle cloud were analyzed. The propagation velocity of the flame is quite slow in the initial 14 ms and then accelerates to maxim...

2010-01-01

124

Field test studies of our infrared-based human temperature screening system embedded with a parallel measurement approach  

British Library Electronic Table of Contents (United Kingdom)

This paper introduces a parallel measurement approach for fast infrared-based human temperature screening suitable for use in a large public area. Our key idea is based on the combination of simple image processing algorithms, infrared technology, and human flow management. With this multidisciplinary concept, we arrange as many people as possible in a two-dimensional space in front of a thermal imaging camera and then highlight all human facial areas through simple image filtering, image morphological, and particle analysis processes. In this way, an individual's face in live thermal image can be located and the maximum facial skin temperature can be monitored and displayed. Our experiment shows a measured 1ms processing time in highlighting all human face areas. With a thermal imaging ca...

2009-01-01

125

Design and testing of fixed-wing MAVs  

British Library Electronic Table of Contents (United Kingdom)

Purpose - This study aims to design and test some fixed-wing micro aerial vehicles (MAV). Design/methodology/approach - The MAV wing planform in this study was designed based on previous results and the need to reduce the weight of the MAV. The MAV had a wing planform with a 6 percent Gottingen-329 camber airfoil, a 20 swept-back leading edge and a straight trailing edge. The fuselage was designed to contain a motor, an electronic control system and a video camera with a built-in transmitter. The battery was located outside the fuselage to trim the center of gravity and enable the battery to be changed easily when it has run out. Two exaggerated vertical stabilizers were installed to prevent the MAV from rolling. The materials, the power plant and the electronics used to fabricate the MAV ...

2007-01-01

126

TECAB - Totally Endoscopic Coronary Artery Bypass  

Medline Plus

... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...

127

Gamma-ray spectrometric analysis of nuclides formed in thorium by neutron irradiation  

International Nuclear Information System (INIS)

Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).

1985-02-01

128

Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning  

International Nuclear Information System (INIS)

The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).

129

Biological wound dressings sterilized with gamma radiation: Mexican clinical experience  

British Library Electronic Table of Contents (United Kingdom)

Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is "Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation". At present, more than 150 patients from 16 hosp...

2007-01-01

130

Rayleigh Laser Guide Star Systems UnISIS Bow Tie Shutter and CCD39 Wavefront Camera  

CERN Document Server

Laser guide star systems based on Rayleigh scattering require some means to deal with the flash of low altitude laser light that follows immediately after each laser pulse. These systems also need a fast shutter to isolate the high altitude portion of the focused laser beam to make it appear star-like to the wavefront sensor. We describe how these tasks are accomplished with UnISIS, the Rayleigh laser guided adaptive optics system at the Mt. Wilson Observatory 2.5-m telescope. We use several methods: a 10,000 RPM rotating disk, dichroics, a fast sweep and clear mode of the CCD readout electronics on a 10 $\\mu$s timescale, and a Pockel's cell shutter system. The Pockel's cell shutter would be conventional in design if the laser light were naturally polarized, but the UnISIS 351 nm laser is unpolarized. So we have designed and put into operation a dual Pockel's cell shutter in a unique bow tie ...

2002-01-01

131

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the ...

2010-01-01

132

Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02  

Energy Technology Data Exchange (ETDEWEB)

Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from ...

2004-12-15

133

Application of conventional laser technology to gamma-gamma colliders  

International Nuclear Information System (INIS)

A future e"-e"+ (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an #gamma#-#gamma# (gamma-gamma) or a e"--#gamma# collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e"-e"+ configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also address concerns ...

1994-03-28

134

Application of conventional laser technology to gamma-gamma colliders  

Energy Technology Data Exchange (ETDEWEB)

A future e{sup -}-e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup -}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup -}-e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5-15 kW from the laser which is beyond the current state of the art. In this paper, we address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. We also address ...

1995-02-01

135

Application of conventional laser technology to gamma-gamma colliders  

Energy Technology Data Exchange (ETDEWEB)

A future e{sup {minus}}e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup {minus}}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup {minus}}e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser ...

1995-02-01

136

Detection system characteristics using sup 252 Cf ionization chambers  

Energy Technology Data Exchange (ETDEWEB)

Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This ...

1990-01-01

137

The effects of applied magnetic fields on the {alpha}/{gamma} phase boundary in the Fe-Si system  

Energy Technology Data Exchange (ETDEWEB)

The CALPHAD (calculations of phase diagrams) method is used to examine the effects of applied magnetic fields on the {alpha}/{gamma} phase boundary in the Fe-Si system in the paramagnetic state. The reported susceptibility data for pure Fe is first re-evaluated. The contributions to the total Gibbs energy of the ferrite ({alpha}) and austenite ({gamma}) from the external fields are calculated based on the Curie-Weiss law and the re-evaluated susceptibility data. The Fe-Si phase diagram on the Fe-rich side as a function of applied field is calculated using the Thermo-Calc(TM) package. With increasing field strength, the {gamma} loop shrinks monotonically; that is, the {alpha}/{gamma}-Fe transition temperature increases while that for {gamma}/{delta}-Fe transition decreases, albeit more slowly. Finally, in conformance with the existing CALPHAD databank, ...

2006-07-21

138

Inventory determination of low and intermediate level radioactive waste of Paks Nuclear Power Plant origin  

International Nuclear Information System (INIS)

In the execution of disposal of low and intermediate level radioactive wastes, it is important to evaluate accurately the kind and quantity of each radionuclide in the wastes. For such an evaluation, correlation of non-gamma-emitting nuclides based on gamma-emitting nuclides is recommended and regarded as a partial method. This method necessitates a completion of a highly accurate and reliable nondestructive assay system of gamma-emitting nuclides for partical use. In 1992, in support of the new waste disposal program in Hungary, Paks NPP initiated a waste characterization program to determine the radiological properties of its rad wastes. A segmented gamma scanning system has been set up to measure the gamma-emitting nuclides in 2000 litre low level drums following in-drum compaction. In the framework of the program a radiochemical analysis ...

139

Production of three vector bosons in #gamma# #gamma# colliders  

International Nuclear Information System (INIS)

The production of three vector bosons in #gamma# #gamma# collisions studying the reactions #gamma# + #gamma# #-># W"+ + W"- + Z"0 and #gamma# + #gamma# #-># W"+ + W"- + #gamma#. 12 refs., 4 figs., 2 tabs.

140

Measuring q sub 0 using supernovae at z approx 0. 3  

Energy Technology Data Exchange (ETDEWEB)

The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this system should ...

1992-07-01

141

First Light for MIRSI  

Science.gov (United States)

We will present the first astronomical images taken with MIRSI (Mid-InfraRed Spectrometer and Imager). First light for MIRSI is scheduled for December 2001. MIRSI is a mid-infrared camera system recently completed at Boston University that has both spectroscopic and imaging capabilities. The camera utilizes a new 320x240 Si:As IBC array developed for ground-based astronomy by Raytheon/SBRC. MIRSI offers a large field of view (1.6 arcmin x 1.2 arcmin at the IRTF with a pixel scale of 0.3 arcsec), diffraction-limited spatial resolution, complete spectral coverage over the 8-14 micron and 17-26 micron atmospheric windows for both imaging (discrete filters and CVF) and spectroscopy (10 and 20 micron grisms), and high sensitivity (expected 1-sigma point source sensitivities of 5 and 20 mJy at 10 and 20 microns, respectively, for on-source integration time of 30 seconds). This system offers the unique ability ...

2001-12-01

142

Inactivation of aflatoxin B1 by using the synergistic effect of hydrogen peroxide and gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Inactivation of aflatoxin B1 was studied by using gamma radiation and hydrogen peroxide. A 100-krad dose of gamma radiation was sufficient to inactivate 50 micrograms of aflatoxin B1 in the presence of 5% hydrogen peroxide, and 400 krad was required for total degradation of 100 micrograms of aflatoxin in the same system. Degradation of aflatoxin B1 was confirmed by high-pressure liquid chromatographic and thin-layer chromatographic analysis. Ames microsomal mutagenicity test showed loss of aflatoxin activity. This method of detoxification also reduces the toxin levels effectively in artificially contaminated groundnuts.

1989-02-01

143

Flight Performance of the AKARI Cryogenic System  

CERN Document Server

We describe the flight performance of the cryogenic system of the infrared astronomical satellite AKARI, which was successfully launched on 2006 February 21 (UT). AKARI carries a 68.5 cm telescope together with two focal plane instruments, Infrared Cameras (IRC) and Far Infrared Surveyor (FIS), all of which are cooled down to cryogenic temperature to achieve superior sensitivity. The AKARI cryogenic system is a unique hybrid system, which consists of cryogen (liquid helium) and mechanical coolers (2-stage Stirling coolers). With the help of the mechanical coolers, 179 L (26.0 kg) of super-fluid liquid helium can keep the instruments cryogenically cooled for more than 500 days. The on-orbit performance of the AKARI cryogenics is consistent with the design and pre-flight test, and the boil-off gas flow rate is as small as 0.32 mg/s. We observed the increase of the major axis of the AKARI orbit, which can ...

2007-01-01

144

Laboratory robotics projects in the Analytical Development Division at the Savannah River Laboratory  

International Nuclear Information System (INIS)

To encourage the application of robotics technology for routine radiobench applications, a laboratory dedicated to the research and development of contained robotic systems is being constructed. The facility will have several robots located in laminar flow hoods, and the hoods are being designed to allow the possibility for multiple robots to work together. This paper presents both the design features of the hoods and the general layout of the laboratory, and also discusses an application of a robotic system for the routine nuclear counting of gamma tube samples. The gamma tube system is presently operating in one of the routine analysis laboratories. 5 figs.

145

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger neutron flux (7.3 x 10[sup 7] n/cm[sup 2]/s) ...

1992-01-01

146

Design concept and testing of an in-bundle gamma densitometer for subchannel void fraction measurements in the THTF electrically heated rod bundle  

International Nuclear Information System (INIS)

A design concept is presented for an in-bundle gamma densitometer system for measurement of subchannel average fluid density and void fraction in rod or tube bundles. This report describes (1) the application of the design concept to the Thermal-Hydraulic Test Facility (THTF) electrically heated rod bundle; and (2) results from tests conducted in the THTF.

147

Basic consideration on high power free-electron lasers  

Energy Technology Data Exchange (ETDEWEB)

An FEL amplifier to generate a laser power of the order of TW at 4 {mu}m wavelength is investigated for a {gamma}-{gamma} collider. A concept of an amplifier chain consisting of a phase-displacement deceleration FELs is proposed to increase the FEL efficiency and to mitigate the requirement for the beam energy spread. The feasibility of the driving linac for the FEL system is also discussed. ((orig.)).

1995-02-01

148

Basic consideration on high power free-electron lasers  

International Nuclear Information System (INIS)

An FEL amplifier to generate a laser power of the order of TW at 4 #mu#m wavelength is investigated for a #gamma#-#gamma# collider. A concept of an amplifier chain consisting of a phase-displacement deceleration FELs is proposed to increase the FEL efficiency and to mitigate the requirement for the beam energy spread. The feasibility of the driving linac for the FEL system is also discussed. ((orig.)).

149

Performance of a modified two-dimensional gamma scan system in spent fuel pin studies  

International Nuclear Information System (INIS)

This work assesses the performance of a modified two-dimensional gamma scan system in spent fuel pin studies. The techniques for a two-dimensional gamma scan studied have been developed at the Hot Cell of Institute of Nuclear Energy Research (INER). Samples are acquired from the spent fuel pin, TPC-SP-C1, which was irradiated in a commercial reactor core (the first of its kind in Taiwan) for 2 years and then deposited in a cooling pool for 10 years. The spent fuel pin was then transferred into INER for further examination. The gamma scanning system was driven by a step motor which had an accuracy within 0.1 mm in both X-Y directions. Data obtained from this system are presented in both an isotopic distribution and contour plot. Results in this study closely correspond to those in other investigations, thereby confirming the effectiveness of this modified ...

1999-11-01

150

Study of "1"0"1Mo decay  

International Nuclear Information System (INIS)

The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. From the coincidence data, the new decay scheme was constructed. The previously reported 104.70, 105.95 and 774.15 keV #gamma# rays were observed, and have been assigned to the decay scheme for the first time. A newly observed 1508.01 keV #gamma# ray has also been assigned to the scheme for the first time. The intensities of #beta#"- and the values of log ft to most levels were calculated

2000-04-01

151

Resonant CP violation in MSSM Higgs production and decay at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We study CP-violating phenomena in the production, mixing and decay of a coupled system of CP-violating neutral Higgs bosons at {gamma}{gamma} colliders, assuming a Minimal Supersymmetric Standard Model (MSSM) Higgs sector in which CP violation is radiatively induced by phases in the soft supersymmetry-breaking gaugino masses and third-generation trilinear squark couplings. We discuss CP asymmetries in the production and decays of {mu}{sup +}{mu}{sup -}, {tau}{sup +}{tau}{sup -}, b-bar b and t-bar t pairs. We find large asymmetries when two (or all three) neutral Higgs bosons are nearly degenerate with mass differences comparable to their decay widths, as happens naturally in the CP-violating MSSM for values of tan{beta}-bar 5 (30) and large (small) charged Higgs-boson masses.

2005-07-04

152

Resonant CP violation in MSSM Higgs production and decay at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study CP-violating phenomena in the production, mixing and decay of a coupled system of CP-violating neutral Higgs bosons at #gamma##gamma# colliders, assuming a Minimal Supersymmetric Standard Model (MSSM) Higgs sector in which CP violation is radiatively induced by phases in the soft supersymmetry-breaking gaugino masses and third-generation trilinear squark couplings. We discuss CP asymmetries in the production and decays of #mu#"+#mu#"-, #tau#"+#tau#"-, b-bar b and t-bar t pairs. We find large asymmetries when two (or all three) neutral Higgs bosons are nearly degenerate with mass differences comparable to their decay widths, as happens naturally in the CP-violating MSSM for values of tan#beta#-bar 5 (30) and large (small) charged Higgs-boson masses.

2005-07-04

153

Neutron star evolution and emission  

Science.gov (United States)

This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.

1997-08-01

154

Effect of alloying on the phase transformations and properties of a nickel alloy  

Energy Technology Data Exchange (ETDEWEB)

The phase transformations and properties of a precipitation-hardened Ni-Cr-based alloy are investigated as a function of C, B, Nb, and Cr contents. It is found that the primary role of Nb consists in the formation of an independent phase, delta-Ni3Nb, a part of a gamma/gamma-prime-delta eutectoid (for high C and B concentrations) and in stimulating the gamma-sigma reaction consecutively with the gamma double prime-delta reaction (for low C and B concentrations). In both cases, the long-term strength characteristics of the Nb-alloyed system are relatively low. The substitution of boron for carbon contributes to a reduction in the number of nucleation sites for topologically close-packed phases and to the formation of more stable (with respect to excess compounds) M3B2 and MB2 borides. The high-boron material exhibits better properties and phase stability under mechanical and thermal loading. 13 ...

1986-07-01

155

An MS-DOS-based program for analyzing plutonium gamma-ray spectra  

Energy Technology Data Exchange (ETDEWEB)

A plutonium gamma-ray analysis system that operates on MS-DOS-based computers has been developed for the International Atomic Energy Agency (IAEA) to perform in-field analysis of plutonium gamma-ray spectra for plutonium isotopics. The program titled IAEAPU consists of three separate applications: a data-transfer application for transferring spectral data from a CICERO multichannel analyzer to a binary data file, a data-analysis application to analyze plutonium gamma-ray spectra, for plutonium isotopic ratios and weight percents of total plutonium, and a data-quality assurance application to check spectral data for proper data-acquisition setup and performance. Volume 3 contains the software listings for these applications.

1989-09-07

156

A chirped-pulse regenerative-amplifier FEL for the gamma-gamma collider  

International Nuclear Information System (INIS)

During a Workshop on Gamma-Gamma Colliders in Lawrence Berkeley Laboratory, it was pointed out that an 1-#mu#m laser that can produce 1-J, 1-ps pulses at a few hundred hertz is required. With high-power scalability and ease of formatting, an FEL can be a promising candidate for such a laser. The authors propose an FEL scheme based on chirped-pulsed regenerative amplification to achieve this high peak-power laser. The 1-ps pulse of a solid-state laser will be stretched, amplified, and recompressed to achieve the high peak power. The system is relatively simple and consists of mostly components that have already been demonstrated. This paper will describe the proposal and the important issues of such a scheme.

1995-05-01

157

A chirped-pulse regenerative-amplifier FEL for the gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

During a Workshop on Gamma-Gamma Colliders in Lawrence Berkeley Laboratory, it was pointed out that an 1-{mu}m laser that can produce 1-J, 1-ps pulses at a few hundred hertz is required. With high-power scalability and ease of formatting, an FEL can be a promising candidate for such a laser. The authors propose an FEL scheme based on chirped-pulsed regenerative amplification to achieve this high peak-power laser. The 1-ps pulse of a solid-state laser will be stretched, amplified, and recompressed to achieve the high peak power. The system is relatively simple and consists of mostly components that have already been demonstrated. This paper will describe the proposal and the important issues of such a scheme.

1995-05-01

158

Measurement of gamma-ray detection efficiency in irradiated materials examination facility  

Energy Technology Data Exchange (ETDEWEB)

The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in ...

2001-05-01

161

Comparison of the e"+e"-, #gamma#e, #gamma##gamma# linear colliders  

International Nuclear Information System (INIS)

The possibility to transform the future linear e"+e"-colliders into the #gamma#e and #gamma##gamma# colliders with approximately the same energies and luminosities was shown earlier. Their properties are compared from the point of view of possible physical investigations on them. 10 refs.; 1 tab.

1992-06-02

162

$\\gamma/\\phi_3$ at hadron colliders  

CERN Document Server

$\\gamma/\\phi_3$ at hadron colliders

2011-01-01

163

Analysis of coupled neutron-gamma radiations by the multigroup Albedo method applied to multilayered slab shieldings  

International Nuclear Information System (INIS)

Full text: The principal nuclear design tools available to the shielding designer include diffusion approximation, transport theory, and Monte Carlo techniques. Full transport theory or Monte Carlo methods are routinely used for shielding analyses, where penetration investigations are more sensitive to directional aspects. However, the aim of this paper is to illustrate the coupled neutron-gamma Albedo method particularly as applied to problems of shielding analysis. The multigroup Albedo method is applied to coupled neutron-gamma radiations considering 'n' neutron energy groups and 'g' gamma energy groups to estimate the probabilities of transmission through, absorption in, and reflection from shieldings composed by multiple material layers, 'm' slabs, in which no fission occurs. In this study, these energy groups were selected in order to minimize upscattering effects of the radiation from lower energy groups to higher ...

164

Modular symmetry in parametrically excited quantum oscillators  

Energy Technology Data Exchange (ETDEWEB)

It is shown that when a quantum mechanical oscillator is parametrically excited there are special values of the parameters for which the system will pass periodically through a lattice of coherent states associated with the modular group [Gamma]. It is shown that these [Gamma] transits can be used to determine unknown parameters. A method is given for detecting the transits experimentally and is made possible by the existence of three families of states associated with modular forms that are orthogonal to the lattice. For isotropic states the three families occur in [ital D]-mode systems with [ital D][gt]10, 14, and 26.

1993-11-29

165

Development of the SRS environmental counting laboratory gamma spectroscopy system  

International Nuclear Information System (INIS)

The Savannah River Site (SRS), one of several U.S. Department of Energy (DOE) facilities, produces nuclear materials for national defense and for other government and civilian uses. SRS ceased production of defense materials in 1988, and the site's main activities now involve waste management and environmental restoration. These programs have generated extensive effluent monitoring and environmental surveillance programs for the Environmental Monitoring Section (EMS), which performs #approx#105,000 radiological analyses on 30,000 samples a year. Gamma spectroscopy is performed on an estimated 10,000 samples annually. This report describes a program to develop and improve the EMS system.

1996-06-16

166

Development and application of gamma scanning technology for on-line investigation of industrial process columns and vessels  

International Nuclear Information System (INIS)

Plant Assessment Technology (PAT) group, in association with Intelligent System (IS) Group and Engineering Services Department of Malaysian Institute for Nuclear Technology Research (MINT) has developed gamma scanning facilities for on-line investigation of industrial process columns and vessels. The technology, based on the principle of gamma-ray absorption, has been successfully applied for troubleshooting of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, case studies are also presented. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. ...

1998-10-30

167

A novel gamma scanning system for on-line diagnostic inspection of industrial process columns  

International Nuclear Information System (INIS)

A computerised gamma scanning facilities for on-line investigation of industrial process columns and vessels has been developed by the Malaysian Nuclear Agency (Nuclear Malaysia). The technology, based on the principle of gamma-ray absorption, has been successfully applied for real-time troubleshooting, process investigation and predictive maintenance of a number of distillation columns and process vessels in petroleum refineries, gas processing plants and chemical plants in the country and the surrounding region. This paper outlines basic characteristics of the system and describes the inspection procedures, and in addition, presents a number of case studies. The case studies are purposely chosen to illustrate the versatility of the technology, and furthermore to demonstrate the economic benefits which can be realised from the application of this technology. (Author)

168

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

Energy Technology Data Exchange (ETDEWEB)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the {sup 137}Cs-source with 10.4 GBq and {sup 60}Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form {sup 137} Cs 1173.23 and 1332.51 keV{sup 60} Co sources, and 14 peaks of {sup 134}Cs and {sup 154}Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that ...

2003-10-01

169

Absolute detection efficiency of radiation detecting system for gamma-ray from sources with high activity  

International Nuclear Information System (INIS)

In this experiment, we measured the detection efficiency of gamma-scanning system of Irradiated Materials Examination Facility (IMEF) in Korea Atomic Energy Research Institute(KAERI) for the spent PWR fuel and activity known sources with high activity. We measured the absolute detection efficiency of gamma scanning system of IMEF to the "1"3"7Cs-source with 10.4 GBq and "6"0Co source with 25.9 GBq High-activity sources as standard sources, and a fuel burned in the KORI -1 reactor of the Kori Nuclear power plant. In analyzing, we used three peeks those were the 661.64 keV peak form "1"3"7 Cs 1173.23 and 1332.51 keV"6"0 Co sources, and 14 peaks of "1"3"4Cs and "1"5"4Eu on the spent fuel gamma spectrum which are in the energy range from 500 to 1,600 keV. We find second order equations for detection efficiency by using our experimental results. The equation show that the detection ...

2003-10-01

170

A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath  

International Nuclear Information System (INIS)

The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in the heat transfer process. A physical ...

1985-10-01

171

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method; Analise das radiacoes neutron e gama acopladas, aplicada a blindagem com varias camadas pelo metodo multigrupo do albedo  

Energy Technology Data Exchange (ETDEWEB)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the ...

2002-07-01

172

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method  

International Nuclear Information System (INIS)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance resulting from the ...

2002-01-01

173

Production of three vector bosons in {gamma} {gamma} colliders; Producao de tres bosons vetoriais em {gamma} {gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The production of three vector bosons in {gamma} {gamma} collisions studying the reactions {gamma} + {gamma} {yields} W{sup +} + W{sup -} + Z{sup 0} and {gamma} + {gamma} {yields} W{sup +} + W{sup -} + {gamma}. 12 refs., 4 figs., 2 tabs.

1994-12-31

174

Burnup determination of spent nuclear fuel in the pool  

Energy Technology Data Exchange (ETDEWEB)

A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used ...

1998-06-01

175

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

176

The Effect of Experience on Male Courtship and Mating Behaviors in a Cellar Spider  

Science.gov (United States)

... video recorded in an isolated booth under a Panasonic WV-CP470 video camera located in an environmentally ... ...

177

Sun rises on station era - Johnson Space Center - NASA  

Science.gov (United States)

Dec 4, 1998 ... throwing a single switch to as complex as the Spartan deploy and retrieve. ...... The camera, called the Acousto-Optic ...

178

SD 571 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

monitoring of open pit mining operations. INTRODUCTION. Aerial photography has long been a useful tool for geologists. Cameras ...

179

Genesis : Search for Origins | JPL | NASA  

Science.gov (United States)

(telescopes, cameras, mirrors, solar cookers); Explain to students that the Genesis spacecraft has a concentrator that collects special types of atoms from ...

180

+ September 2006 - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Post-drive imaging included 360-degree view by the navigation camera and .... Sol 938: Opportunity completed another assessment of the clarity of the sky. ...

181

FFTF fission gas monitor computer system  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled test reactor located on the Hanford site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The fission gas monitor system makes extensive use of commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows one monitor to be taken out of service for periodic tests or ...

182

Development of food preservation and processing techniques by radiation  

International Nuclear Information System (INIS)

Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 kGy) in areas such as genotoxicity, acute ...

1988-04-18

183

Beta and gamma decay heat measurements between 0.1s - 50,000s for neturon fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Progress report, June 1, 1992--December 31, 1994  

Energy Technology Data Exchange (ETDEWEB)

In the investigations reported here, a helium-jet/tape-transport system was used for the rapid transfer of fission products to a low-background environment where their aggregate beta and gamma-ray spectra were measured as a function of delay time after neutron induced fission of {sup 235}U, {sup 238}U and {sup 239}Pu. Beta and gamma-ray energy distributions have been deduced for delay times as short as 0.2 s and extending out to 100,000s. Instrumentation development during the initial phase of the project included: (1) assembly and characterization of a NaI(Tl) spectrometer for determining aggregate gamma-ray energy distributions, (2) development and characterization of a beta spectrometer (having excellent gamma-ray rejection) for measuring aggregate beta-particle energy distributions, (3) assembly and characterization of a Compton-suppressed HPGe spectrometer for determining ...

1997-05-01

184

Video equipment of tele dosimetry and audio  

International Nuclear Information System (INIS)

To develop a work in an area with high radiation, it requires of a detailed knowledge of the surroundings work, a communication and effective vision, a near dosimetric control. In a work where the spaces variables and reduced accesses exist, noise that hinders the communication, defendant operative condition, radiation field and taking of decision, it is necessary to have tools that allow a total control of the environment to make opportune and effective decisions, there where the task is developed. Under this elementary concept, it was developed in the Laguna Verde Central a project that it allowed a mechanism, interactive of control in spaces complex; to see, to hear, to speak, to measure. This concept takes to the creation of an equipped system with closed circuit of television, wireless communication systems, tele dosimetry wireless systems, VHS and DVD recording equipment, uninterrupted energy units. The ...

2007-07-01

185

Short wave length and high qualification of free-electron laser  

International Nuclear Information System (INIS)

The oscillation experiment of free-electron laser (FEL) was carried at the wave length 488 nm. The space and time properties and power of FEL were investigated. The typical macropulse structure indicated the time interval 20 ms and the pulse width 2 to 3 ms. About 1 ns was necessary to build up FEL. The space distribution of FEL showed beautiful TEM_0_0 mode, TEM_0_1 and TEM_0_2 mode. On the basis of data, 39 #mu#W average power was calculated at 2.9 mA accumulated current per bunch by integrating each response of pixel of CCD camera. The peak power was 1.2 W. In the oscillator, FEL power was average 1.2 W, peak 38 kW. On the electron beam, the stability of head tail was controlled by 6-pole-Quadrupole-6-pole (SQS) system made by an experimental basis. We succeeded the single set test, setting up single set in the ring. The characteristic properties of electron beam evaporation mirror of photo oscillator were studied and then new type photo ...

1998-02-01

186

Seasonal characteristics of lightning channel and its relationship to transmission line faults; Kaminari hodenro no kisetsu tokusei to sodensen jiko no kankei  

Energy Technology Data Exchange (ETDEWEB)

In the Hokuriku area along the coast of the Japan Sea, thunderstorms often occurred not only in summer but also in winter, and this resulted in the shutdown of electricity supply or damage of equipment. This study was concerning the observation of the lightning channels in the Hokuriku area through a year by many still cameras equipped with liquid-crystal shutters. The following conclusions were obtained: Among 165 lightning incidents photographed during 2 years, there included 172 incidents of the falling thunderstorms and 23 incidents of simultaneously falling thunderstorms at multi-area. In the case of winter, frequency to occur simultaneously falling thunderstorms at multi-area was higher and the upward falling thunderstorms were more. There was a tendency that the duration time of the lightning current in winter was longer than in summer. In winter, frequency to occur the upward falling thunderstorms was higher, about 61% of the upward falling thunderstorms ...

1996-02-20

187

Medical image transmission via communication satellite. Evaluation of bone scintigraphy  

International Nuclear Information System (INIS)

As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6#+-#2.6% via satellite, and 93.2#+-#2.4% on the view ...

188

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...

2006-12-01

189

Detection of H2 Emission from Mira B in UV Spectra from the Hubble Space Telescope  

CERN Document Server

We present ultraviolet spectra of Mira's companion star from the Space Telescope Imaging Spectrograph (STIS) instrument on board the Hubble Space Telescope (HST). The companion is generally assumed to be a white dwarf surrounded by an accretion disk fed by Mira's wind, which dominates the UV emission from the system. The STIS UV spectrum is dominated by numerous, narrow H2 lines fluoresced by H I Ly-alpha, which were not detected in any of the numerous observations of Mira B by the International Ultraviolet Explorer (IUE). The high temperature lines detected by IUE (e.g., C IV 1550) still exist in the STIS spectrum but with dramatically lower fluxes. The continuum fluxes in the STIS spectra are also much lower, being more than an order of magnitude lower than ever observed by IUE, and also an order of magnitude lower than fluxes observed in more recent HST Faint Object Camera objective prism spectra from 1995. Thus, the accretion rate onto Mira ...

2001-01-01

190

A Survey of Local Group Galaxies Currently Forming Stars: \\\\II. UBVRI Photometry of Stars in Seven Dwarfs  

CERN Document Server

We have obtained UBVRI images with the Kitt Peak and Cerro Tololo 4-m telescopes and Mosaic cameras of seven dwarfs in (or near) the Local Group, all of which have known evidence of recent star formation: IC10, NGC 6822, WLM, Sextans B, Sextans A, Pegasus,and Phoenix. We construct color-magnitude diagrams (CMDs) of these systems, as well as neighboring regions that can be used to evaluate the degree of foreground contamination by stars in the Milky Way. Inter-comparison of these CMDs with those of M31, M33, the LMC, and the SMC permits us to determine improved reddening values for a typical OB star found within these galaxies. All of the CMDs reveal a strong or modest number of blue supergiants. All but Pegasus and Phoenix also show the clear presence of red supergiants in the CMD, although IC10 appears to be deficient in these objects given its large WR population. The bright stars of intermediate color in the CMD are badly contaminated by ...

2007-01-01

191

A Simulation Study on a Radioactive Nuclide's Distribution within a Fuel rod by a Tomographic Gamma Scanning  

Energy Technology Data Exchange (ETDEWEB)

Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and ...

2006-07-01

192

Biological wound dressings sterilized with gamma radiation: Mexican clinical experience  

International Nuclear Information System (INIS)

Biological wound dressings sterilized with gamma radiation, such as amnion and pig skin, are a reality in Mexico. These tissues are currently processed in the tissue bank and sterilized in the Gamma Industrial Irradiation Plant; both facilities belong to the Instituto Nacional de Investigaciones Nucleares (ININ) (National Institute of Nuclear Research). With the strong support of the International Atomic Energy Agency, the bank was established at the ININ and the Mexican Ministry of Health issued its sanitary license on July 7, 1999. The Quality Management System of the bank was certified by ISO 9001:2000 on August 1, 2003; the scope of the system is 'Research, Development and Processing of Biological Tissues Sterilized with Gamma Radiation'. At present, more than 150 patients from 16 hospitals have been successfully treated with these tissues. This paper presents a brief ...

2007-11-01

193

Studies of the low-lying levels in /sup 192/Pt and /sup 192/Os  

Energy Technology Data Exchange (ETDEWEB)

The energy level schemes of /sup 192/Os and /sup 192/Pt have been established on the basis of ..gamma..-..gamma.. coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and ..beta../sup -/ decays of /sup 192/Ir to /sup 192/Os and /sup 192/Pt, respectively. Thirteen new transitions and three new levels at 1146.95, 1237.35 and 1913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, ..cap alpha..(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition.

1985-02-01

194

Studies of the low-lying levels in "1"9"2Pt and "1"9"2Os  

International Nuclear Information System (INIS)

The energy level schemes of "1"9"2Os and "1"9"2Pt have been established on the basis of #gamma#-#gamma# coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and #beta#"- decays of "1"9"2Ir to "1"9"2Os and "1"9"2Pt, respectively. Thirteen new transitions and three new levels at 1,146.95, 1,237.35 and 1,913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, #alpha#(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition. (orig.).

1985-01-01

195

Lipid composition of liver microsomes and mitochondria after acute and chronic {gamma}-irradiation of rats  

Energy Technology Data Exchange (ETDEWEB)

Acute {gamma}-irradiation of rats at doses of 100 and 270 Gy stimulates lipid synthesis and changes the lipid composition of liver cell organelles. The content of cholesterol and cholesterol esters in microsomes increased at 100 Gy and decreased at 270 Gy, with total phospholipid content remaining unchanged. The lipid content in mitochondria decreased considerably 1 h after irradiation at 270 Gy. This change was significantly less pronounced 47 h later. Under chronic {gamma}-irradiation (0.129 Gy/day), cholesterol and cardiolipin in mitochondria increased. The changes in lipid content caused by acute irradiation are presumed to be related to activated synthesis of lipids in the liver. The modification of the lipid content of mitochondria observed in chronically irradiated rats may indicate that energy-metabolizing liver cell systems are involved in the adaptation to irradiation.

1994-07-01

196

Gamma irradiation induced damage creation on the cation distribution, structural and magnetic properties in Ni-Zn ferrite  

International Nuclear Information System (INIS)

Ferrite of system, namely Ni_1_-_xZn_xFe_2O_4 with x = (0.0, 0.2, 0.4, 0.6, 0.8, 1.0), have been prepared by solid state reaction to investigate the effect of gamma rays irradiations using Co"6"0 source on the cation distribution, structural and magnetic properties. The unirradiated and irradiated samples were then subjected to characterization techniques such as X-ray diffraction, magnetization and AC susceptibility. The results of these characterizations are found to be different for irradiated from that of the pristine sample. The modifications in respect of irradiated samples are explained in terms of the ion-induced disorder. The important result of #gamma#-irradiation on the cation distribution, structural and magnetic properties is the change of ratio Fe"2"+/Fe"3"+. Possible reasons on the results are proposed.

2010-09-01

197

Disordered bcc γ-phase to δ-phase transformation in Zr-rich U-Zr alloy  

British Library Electronic Table of Contents (United Kingdom)

The transformation mechanism of hexagonal delta phase from the disordered bcc gamma phase has not been reported before in the Zr-rich U-Zr alloy system. With the help of X-ray diffraction, transmission electron microscopy (TEM) and high-resolution TEM analyses it was shown that the gamma to delta conversion takes place by the lattice collapse mechanism of omega transformation. It was also ascertained that a higher aging temperature or time promotes the growth of all four variants of the delta phase within a parent gamma grain. In addition, ab initio electronic structure calculations showed that the bcc to hexagonal transformation, involving partial ordering of the parent bcc phase followed by (111) plane collapse, is energetically favorable.

2011-01-01

198

Synthesis and biodistribution of nitrido technetium-99m radiopharmaceuticals with dithiophosphinate ligands: a class of brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

The symmetrical complexes [{sup 99m}Tc][TcN(R{sub 2}PS{sub 2}){sub 2}] [R = CH{sub 3}, CH{sub 2}CH{sub 3}, CH{sub 2}CH{sub 2}CH{sub 3}, CH{sub 2}(CH{sub 3}){sub 2}], and the unsymmetrical complex [{sup 99m}Tc][TcN(Me{sub 2}PS{sub 2})(Et{sub 2}PS{sub 2})] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R{sub 2}PS{sub 2}]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding {sup 99}Tc-analogs prepared, at macroscopic level, by reacting the complex [{sup 99}TcNCl{sub 4}] [n-Bu{sub 4}N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two ...

1995-04-01

199

Synthesis and biodistribution of nitrido technetium-99m radiopharmaceuticals with dithiophosphinate ligands: a class of brain imaging agents  

International Nuclear Information System (INIS)

The symmetrical complexes ["9"9"mTc][TcN(R_2PS_2)_2] [R = CH_3, CH_2CH_3, CH_2CH_2CH_3, CH_2(CH_3)_2], and the unsymmetrical complex ["9"9"mTc][TcN(Me_2PS_2)(Et_2PS_2)] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R_2PS_2]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding "9"9Tc-analogs prepared, at macroscopic level, by reacting the complex ["9"9TcNCl_4] [n-Bu_4N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two dithiophosphinate ligands spanning the four positions on the basal plane through the four sulfur atoms of the >PS_2 group. ...

1995-04-01

200

Quantitative bone scintigraphy. A study in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed in patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months after operation. The count rate was recorded as serial gamma camera images over the lower thoracic and all lumbar vertebrae from 1 to 240 min and at 24 h after injection of "9"9"Tc"m-MDP. In almost all abnormal vertebrae an increased count rate was observed within one hour after injection. Most of the vertebrae which were considered normal at 4 h after injection, but had an increased 24h/4h ratio developed into abnormal vertebrae later in the study. The patients with normal bone scintigrams showed no change in "9"9Tc"m-MDP uptake during the study. The reproducibility of quantitative bone scintigraphy was found to be #+-# 7% (1 SD). In response to therapy, most of the patients with abnormal bone scintigrams showed an increase in count rate two weeks after operation followed by a decrease to the ...

1985-06-02

201

Optimizing the radiosensitive liquid-core microcapsules for the targeting of chemotherapeutic agents  

Energy Technology Data Exchange (ETDEWEB)

Microcapsules consisting of alginate and hyaluronic acid that can be decomposed by radiation are currently under development. In this study, the composition of the microcapsule material was optimized by changing the amounts of alginate and hyaluronic acid. Solutions of 0.025%, 0.05%, 0.1%, 0.2%, or 0.4% (wt./vol.) hyaluronic acid were mixed into a 0.2% alginate solution. To these mixtures, carboplatin (0.2 mmol) was added and the resulting material was used for the capsule preparation. The capsules were prepared by spraying the material into a CaCl{sub 2} solution (0.34 mol/l) using a microatomizer. These capsules were irradiated by a single dose of 2, 5, or 10 Gy {sup 60}Co {gamma}-ray radiation. Immediately after irradiation, the releasing of core content of microcapsule was determined, using a micro particle induced X-ray emission (PIXE) camera. The average diameter of the microcapsules was 22.3 {+-} 3.3 {mu}m, and that of the liquid core ...

2007-07-15

202

I-131 labelled peanut lectin renal kinetics in cis-platin induced tubular toxicity in dogs  

International Nuclear Information System (INIS)

Quantitative I-131 labelled Peanut lectin (I-131-PNA) renal clearance was determined in dogs before and after a 5 day single cycle cis-platinum chemotherapy regimen (0.5mg/Kg/day). Results were statistically compared with E.R.P.F. (I-131-Hippuran), G.F.R. (Tc-99m-DTPA), and serum biochemistry and correlated with histopathology. I-131-PNA clearance was significantly reduced in all dogs 5 days after cessation of cis-platinum treatment (mean #DELTA#S% = 71.3%) and similar reductions in the gamma camera derived renogram peak were demonstrated (mean #DELTA#S% = 65.8%). E.R.P.F. was noted to drop by a minor degree (mean #DELTA#S% = 20.9%) post treatment. G.F.R. was diminished (mean #DELTA#S% = 46.6%) and serum creatinine elevated (mean #DELTA#S% = 42.7%) in all dogs compared to their pretreatment values. Histopathology demonstrated variable degrees of tubular toxicity ranging from mild to severe. The degree of change of the I-131-PNA values was ...

1985-06-02

203

Autoradiographic analysis of radiolabeled anti-carcinoembryonic antigen monoclonal antibody CEA 102 in colorectal cancer using computed radiography  

Energy Technology Data Exchange (ETDEWEB)

Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with {sup 131}I-labeled intact CEA 102 or its F(ab'){sub 2}. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of {sup 131}I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted ...

1992-04-01

204

Autoradiographic analysis of radiolabeled anti-carcinoembryonic antigen monoclonal antibody CEA 102 in colorectal cancer using computed radiography  

International Nuclear Information System (INIS)

Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with "1"3"1I-labeled intact CEA 102 or its F(ab')_2. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of "1"3"1I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in ...

1992-01-01

205

166Ho-HA evaluation as therapeutic agent for rheumatoid arthritis treatment  

International Nuclear Information System (INIS)

Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This leads to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate "1"6"6Ho-Hydroxyapatite ("1"6"6 Ho-HA) as potential radiopharmaceutical for the symptomatic treatment of chronic and acute arthritis. Materials and Methods: Holmiun-166 was produced by irradiation of Ho_2O_3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthesized. Its labelling and quality controls follows the internationally accepted procedures. An antigen's arthritis was induced to eight New Zealand rabbits with the "1"6"6 Ho-HA radiochemical being administered thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon clinical improvement and ...

2002-09-01

206

Laser monitoring of the size and polarization of the gamma beams of #gamma##gamma# and e#gamma# colliders  

International Nuclear Information System (INIS)

It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).

207

Excited leptons and quarks at #gamma##gamma#/#gamma#e colliders  

International Nuclear Information System (INIS)

We discuss the search of excited leptons and quarks with spin 1/2 at #gamma##gamma# and at #gamma#e colliders. We show that #gamma##gamma# colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l"*l#gamma# transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).

208

Properties of the quadrupole glass phase in the presence of an external field gradient  

Energy Technology Data Exchange (ETDEWEB)

A model of a solid disordered ortho-parahydrogen mixture with infinite long-range interaction J/sub ij/ between orthomolecules distributed in accordance with a normal law with first moment J/sub 0/ is investigated. It is shown that the introduction of an external electric field gradient ..gamma.. can give rise to a phase transition to an orientational phase. The possible existence of an orientational glass phase is established. The influence of the degeneracy of the hydrogen orthomolecules on the low-temperature thermal properties of these systems is demonstrated, and a condition of stability of the replica-symmetric solution is established. At low temperatures, this solution is stable for a large value of ..gamma.. or J/sub 0/.nctio

1987-11-01

209

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a {sup 60}Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

210

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used.

2001-05-01

211

Gamma-radiation-induced wood-plastic composites from Syrian tree species  

International Nuclear Information System (INIS)

Wood-plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, using three monomer systems; acrylamide, butylmethacrylate, and styrene, with methanol as the swelling solvent. Polymerization was induced at various radiation doses (10, 20, and 30 kGy) at a dose rate of 3.5 kGy/h using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength have been measured. The polymer loading decreases approximately with increasing density of the wood species used. (author)

2002-01-01

212

Achievements in testing of the MGA and FRAM isotopic software codes under the DOE/NNSA-IRSN cooperation of gamma-ray isotopic measurement systems  

Energy Technology Data Exchange (ETDEWEB)

DOE/NNSA and IRSN collaborated on a study of gamma-ray instruments and analysis methods used to perform isotopic measurements of special nuclear materials. The two agencies agreed to collaborate on the project in response to inconsistencies that were found in the various versions of software and hardware used to determine the isotopic abundances of uranium and plutonium. IRSN used software developed internally to test the MGA and FRAM isotopic analysis codes for criteria used to stop data acquisition. The stop-criterion test revealed several unusual behaviors in both the MGA and FRAM software codes.

2009-01-01

213

A database for QA/QC in neutron activation analysis and gamma-ray spectrometry  

International Nuclear Information System (INIS)

A database has been designed for storing, retrieving and analyzing information about samples, experimental conditions and results obtained by neutron activation analysis and gamma-ray spectrometry. It has been created using Microsoft ACCESS 2002 under a Windows operating system. The database has been designed not only for saving information but also for quality assurance and quality control purposes. The structure of the relational design has been discussed and demonstrated with a new graphical feature of ACCESS 2002 called PIVOTCHART. (author)

2007-04-01

214

$B \\to X_{s} \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ decays at LHCb  

CERN Document Server

\\lhcb is one of the four major experiments at the Large Hadron Collider (\\lhc) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavour hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiments. In this article, the \\lhcb prospects for such measurements with exclusive decays of the type $B \\to \\Xs \\gamma$ and $B \\to X_{s} l^{+} l^{-}$ are presented.

2011-01-01

215

$B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ decays at LHCb  

CERN Document Server

LHC$b$ is one the four major experiments at the Large Hadron Collider (LHC) at CERN. It is custom built to look for CP violation and New Physics in rare decays of heavy flavor hadrons, like the B and D systems. Rare decays that occur via loop diagrams provide a way to probe New Physics at energy scales much higher than can be probed by direct production in experiment. In this article, the LHC$b$ prospects for such measurement with exclusive decays of the type $B \\to X_s\\gamma$ and $B\\to X_sl^+l^-$ are presented.

2011-01-01

216

WIDGET: System Performance and GRB Prompt Optical Observations  

CERN Document Server

The WIDeField telescope for Gamma-ray burst Early Timing (WIDGET) is used for a fully automated, ultra-wide-field survey aimed at detecting the prompt optical emission associated with Gamma-ray Bursts (GRBs). WIDGET surveys the HETE-2 and Swift/BAT pointing directions covering a total field of view of 62 degree x 62 degree every 10 secounds using an unfiltered system. This monitoring survey allows exploration of the optical emission before the gamma-ray trigger. The unfiltered magnitude is well converted to the SDSS r' system at a 0.1 mag level. Since 2004, WIDGET has made a total of ten simultaneous and one pre-trigger GRB observations. The efficiency of synchronized observation with HETE-2 is four times better than that of Swift. There has been no bright optical emission similar to that from GRB 080319B. The statistical analysis implies that GRB080319B is a rare event. This paper ...

2010-01-01

217

A mobile gamma scanning system for detecting radiation anomalies  

Energy Technology Data Exchange (ETDEWEB)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A /sup 226/Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

1983-09-01

218

A mobile gamma scanning system for detecting radiation anomalies  

International Nuclear Information System (INIS)

A mobile gamma-ray scanning system has been developed by Oak Ridge National Laboratory for use in the U.S. Department of Energy's remedial action survey programs. The unit consists of NaI(Tl) detectors housed in a specially equipped van. The system is operator controlled through an on-board minicomputer with data output provided on the computer video screen, strip chart recorders, and an on-line printer. Data storage is provided on floppy disk. Multichannel analysis capabilities are included for qualitative radionuclide identification. A "2"2"6Ra-specific algorithm is currently employed to identify locations containing residual radium-bearing materials.

219

A 40 GByte/s read-out system for GEM  

Energy Technology Data Exchange (ETDEWEB)

The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System.

1994-04-01

220

A Liquid Parahydrogen Target for the Measurement of a Parity-violating Gamma Asymmetry in Polarized Neutron Capture on Protons  

Energy Technology Data Exchange (ETDEWEB)

A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical ...

2010-05-01

221

Signatures of extra dimensions at e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The authors study the processes {gamma}e {r{underscore}arrow} {gamma}e and {gamma}{gamma} {r{underscore}arrow} {gamma}{gamma}, in the context of the proposal for Weak Scale Quantum Gravity (WSQG) with large extra dimensions. With an ultraviolet cutoff M{sub S} {approximately} 1 TeV for the effective gravity theory, the cross sections obtained for these processes at the Next Linear Collider (NLC), with the e{gamma} an {gamma}{gamma} options, deviate from the predictions of the Standard Model significantly. The results suggest that, for typical proposed NLC energies and luminosities, the predictions of WSQG can be tested in the range 1 TeV {approx{underscore}lt} M{sub S} {approx{underscore}lt} 10 TeV, making e{gamma} an {gamma}{gamma} colliders important tools for probing WSQG.

2000-01-26

222

#gamma##gamma# Cross-sections and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We summarize the predictions of different models for total #gamma##gamma# cross-sections. The experimentally observed rise of #sigma#_#gamma#_#gamma# with s radical _#gamma#_#gamma#, faster than that for #sigma#_p_-_b_a_r_p, #sigma#_#gamma#_p is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of #sigma#_#gamma#_#gamma# with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range 300< s radical_#gamma#_#gamma# <500 GeV. We further show that the difference in model predictions for ...

2001-10-11

223

Comparison and Physical Interpretation of MCNP and TART Neutron and Gamma Monte Carlo Shielding Calculations for a Heavy-Ion ICF System  

Energy Technology Data Exchange (ETDEWEB)

For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a ...

2002-07-01

224

Quick separation of fission product molybdenum and gamma-rays of Mo-102  

International Nuclear Information System (INIS)

... electrophoresis fission products gamma radiation gamma spectra half-life

225

Probing of the Higgs-fermion coupling at. gamma. gamma. -colliders  

Energy Technology Data Exchange (ETDEWEB)

Three possibilities to observe the Higgs-top interaction at future {gamma}{gamma}-colliders are discussed: (a) associated Higss production via the {gamma}{gamma}{yields}tanti tH reaction, (b) Higgs obliged radiative correction to the {gamma}{gamma}{yields}tanti t channel, (c) Higgs resonance production via {gamma}{gamma}{yields}H{yields}ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at {gamma}{gamma}-colliders. (orig.).

1992-11-01

226

Probing of the Higgs-fermion coupling at #gamma##gamma#-colliders  

International Nuclear Information System (INIS)

Three possibilities to observe the Higgs-top interaction at future #gamma##gamma#-colliders are discussed: a) associated Higss production via the #gamma##gamma##->#tanti tH reaction, b) Higgs obliged radiative correction to the #gamma##gamma##->#tanti t channel, c) Higgs resonance production via #gamma##gamma##->#H#->#ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at #gamma##gamma#-colliders. (orig.).

227

Investigation of W"1"7"7 decay scheme by #gamma##gamma#-coincidence method  

International Nuclear Information System (INIS)

... coincidence spectrometry decay excited states gamma spectra half-life

1973-01-29

228

A small size continuous run industrial gamma irradiator  

Energy Technology Data Exchange (ETDEWEB)

A new small size gamma irradiator is being set up at Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Brazil, with a revolutionary design. The developed technology for this facility consists of continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the shielding, avoiding the traditional maze configuration. Covering 76 m{sup 2} of floor area, the irradiator design is product overlap sources and the maximum capacity of Cobalt-60 wet sources is 37 PBq (1 MCi). The irradiator is being installed in a Governmental Institution and it will be used as a demonstration facility for manufacturers, who need an economic and logistic in-house irradiation system alternative. Also, it will be useful for supporting the local scientific community on development ...

2004-10-01

229

The ''nuclear car wash'': a scanner to detect illicit special nuclear material in cargo containers  

International Nuclear Information System (INIS)

There is an urgent need to improve the reliability of screening cargo containers for illicit nuclear material that may be hidden there for terrorist purposes. A screening system is described for detection of fissionable material hidden in maritime cargo containers. The system makes use of a low intensity neutron beam for producing fission; and the detection of the abundant high-energy #gamma# rays emitted in the #beta#-decay of short-lived fission products and #beta#-delayed neutrons. The abundance of the delayed #gamma# rays is almost an order of magnitude larger than that of the delayed neutrons normally used to detect fission and they are emitted on about the same time scale as the delayed neutrons, i.e., #approx#1 min. The energy and temporal distributions of the delayed #gamma# rays provide a unique signature of fission. Because of their high energy, these delayed ...

2004-01-28

230

Proceedings of the first meeting on e{gamma}/{gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The first meeting on e{gamma}/{gamma}{gamma} colliders was held on September 28 and 29, 1993, at the National Laboratory for High Energy Physics. After general remarks were delivered, lectures were given on QED in intense laser field, photon linear collider, laser focusing, luminosity distribution in the e{gamma}/{gamma}{gamma} colliders, QCD correction for {gamma}{gamma}{yields}H, radiation correction for e{gamma}/{nu}W process, SUSY particle production at the e{gamma} and {gamma} gamma colliders, formation of e{sup *} in e{gamma} collision, and general remarks on the theory. Discussion was carried out on `Where are we going from here?` In this book, the gists of the lectures are collected. (K.I.).

1994-01-01

231

The study of "1"0"1Mo decay  

International Nuclear Information System (INIS)

The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. According to the coincidence data, the decay scheme was modified. The positions of 221.80, 318.00, 377.90, 452.50, 515.42, 1011.05 and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95 and 774.15 keV gamma-rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52 and 1431.68 keV transitions have been reconfirmed, the 1508.01 keV gamma-ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#-intensities and the values of log ft of most levels were calculated. (author)

2000-09-01

232

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring ...

1988-09-01

233

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time ...

1988-01-01

234

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot ...

2007-07-01

235

Deliberate ignition of hydrogen-air-steam mixtures in condensing steam environments  

Energy Technology Data Exchange (ETDEWEB)

Large scale experiments were performed to determine the effectiveness of thermal glow plug igniters to burn hydrogen in a condensing steam environment due to the presence of water sprays. The experiments were designed to determine if a detonation or accelerated flame could occur in a hydrogen-air-steam mixture which was initially nonflammable due to steam dilution but was rendered flammable by rapid steam condensation due to water sprays. Eleven Hydrogen Igniter Tests were conducted in the test vessel. The vessel was instrumented with pressure transducers, thermocouple rakes, gas grab sample bottles, hydrogen microsensors, and cameras. The vessel contained two prototypic engineered systems: (1) a deliberate hydrogen ignition system and (2) a water spray system. Experiments were conducted under conditions scaled to be nearly prototypic of those expected in Advanced Light Water Reactors (such as the ...

1997-05-01

236

Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.

1996-12-31

237

Application of BGO scintillators to absolute measurement of neutron capture cross sections between 0.01 eV and 10 eV  

Energy Technology Data Exchange (ETDEWEB)

Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup ...

1997-07-01

238

Development of an irradiation system for a small size continuous run multipurpose gamma irradiator  

International Nuclear Information System (INIS)

The Radiation Technology Center from IPEN-CNEN/SP, Brazil, developed a revolutionary design and national technology, a small-sized continuous run and multipurpose industrial gamma irradiator, to be used as a demonstration facility for manufacturers and contract service companies, which need economical and logistical in-house irradiation system alternatives. Also, to be useful for supporting the local scientific community on development of products and process using gamma radiation, assisting the traditional and potential users on process validation, training and qualification of operators and radioprotection officers. The developed technology for this facility consists of a continuous tote box transport system, comprising a single concrete vault, where the automated transport system of products inside and outside of the irradiator utilizes a rotating door, integrated with the ...

239

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between ...

1999-07-01

240

RED NUGGETS AT z #approx# 1.5: COMPACT PASSIVE GALAXIES AND THE FORMATION OF THE KORMENDY RELATION  

International Nuclear Information System (INIS)

We present the results of Near-Infrared Camera and Multi-Object Spectrometer (NICMOS) imaging of a sample of 19 high-mass passively evolving galaxies with 1.2 < z < 2, taken primarily from the Gemini Deep Deep Survey (GDDS). Around 80% of galaxies in our GDDS sample have spectra dominated by stars with ages #approx#>1 Gyr. Our rest-frame R-band images show that most of these objects have compact regular morphologies which follow the classical R "1"/"4 law. These galaxies scatter along a tight sequence in the size versus surface brightness parameter space which defines the Kormendy relation. Around one-third (3/10) of the massive red objects in the GDDS sample are extraordinarily compact, with effective radii under 1 kpc. Our NICMOS observations allow the detection of such systems more robustly than is possible with optical (rest-frame UV) data, and while similar systems have been seen at z #approx#> 2, this is ...

2009-04-10

241

Large Scale Laser Two-Photon Polymerization Structuring for Fabrication of Artificial Polymeric Scaffolds for Regenerative Medicine  

Science.gov (United States)

We present a femtosecond Laser Two-Photon Polymerization (LTPP) system of large scale three-dimensional structuring for applications in tissue engineering. The direct laser writing system enables fabrication of artificial polymeric scaffolds over a large area (up to cm in lateral size) with sub-micrometer resolution which could find practical applications in biomedicine and surgery. Yb:KGW femtosecond laser oscillator (Pharos, Light Conversion. Co. Ltd.) is used as an irradiation source (75 fs, 515 nm (frequency doubled), 80 MHz). The sample is mounted on wide range linear motor driven stages having 10 nm sample positioning resolution (XY--ALS130-100, Z--ALS130-50, Aerotech, Inc.). These stages guarantee an overall travelling range of 100 mm into X and Y directions and 50 mm in Z direction and support the linear scanning speed up to 300 mm/s. By moving the sample three-dimensionally the position of laser focus in the photopolymer is changed and ...

2010-11-10

242

Study of the effect of gamma radiation on the molecule of tetracycline concerning its behavior as complexing and extracting agent; Estudo do efeito da radiacao gama sobre a molecula de tetraciclina relativamente ao seu comportamento como agente complexante e extrator  

Energy Technology Data Exchange (ETDEWEB)

Both solvent extraction and spectrophotometric techniques were used to show the alterations that gamma radiation causes in the behavior of tetracycline molecule as far as its extracting and complexing power are concerned. The effect of gamma radiation on the solid tetracycline molecule, benzyl alcohol and on the solution of both was examined in solvent extraction systems whose aqueous phases were made up by {sup 152} Eu-{sup 154}Eu radioactive tracer solutions and whose organic phases were constituted by tetracycline-benzyl alcohol solutions. Experiments were performed in order to determine whether or not the water used for the pre-saturation of benzyl alcohol would influence the radiolysis of tetracycline. Solvent extraction and spectrophotometry were the techniques used to obtain the necessary data. Absorption spectra of irradiated tetracycline benzyl alcohol solutions submitted to several gamma ...

1982-07-01

243

Electron acceleration in supernova remnants and diffuse gamma rays above 1 GeV  

DEFF Research Database (Denmark)

The recently observed X-ray synchrotron emission from four supernova remnants (SNRs) has strengthened the evidence that cosmic-ray electrons are accelerated in SNRs. We show that if this is indeed the case, the local electron spectrum will be strongly time-dependent, at least above roughly 30 GeV. The time dependence stems from the Poisson fluctuations in the number of SNRs within a certain volume and within a certain time interval. As far as cosmic-ray electrons are concerned, the Galaxy looks like actively bubbling Swiss cheese rather than a steady, homogeneously filled system. Our finding has important consequences for studies of the Galactic diffuse gamma-ray emission, for which a strong excess over model predictions above 1 GeV has recently been reported. While these models relied on an electron injection spectrum with index 2.4 (chosen to fit the local electron flux up to 1 TeV), we show that an electron injection index of around 2.0 ...

1998-01-01

245

Semihard production of tensor mesons in #gamma##gamma#-collisions and the perturbative Odderon  

International Nuclear Information System (INIS)

The cross sections of neutral tensor mesons T=a_2, f, f', ... production in the exclusive #gamma##gamma##->#TT' or semiexclusive #gamma##gamma##->#TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV"2 are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future #gamma##gamma#-colliders is discussed too. (orig.).

246

Principles of photon colliders  

Energy Technology Data Exchange (ETDEWEB)

Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).

1995-02-01

247

Composite vector leptoquarks in e"+e-, #gamma#e, and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study the signals for composite vector leptoquarks in e"+e- colliders (CERN e"+e- collider LEP II, Next Linear Collider, and CERN Linear Collider) through their effects on the production of jet pairs, as well as their single and pair productions. We also analyze their production in #gamma#e and #gamma##gamma# collisions.

248

Scaling of the distribution function and the critical exponents near the point of a marginal stability under the Vlasov-Poisson equations  

Energy Technology Data Exchange (ETDEWEB)

A model system, described by the consistent Vlasov-Poisson equations under periodical boundary conditions, has been studied numerically near the point of a marginal stability. The power laws, typical for a system, undergoing a second-order phase transition, hold in a vicinity of the critical point: (i) A {proportional_to} -{theta}{sup {beta}}, {beta}=1.907{+-}0.006 for {theta} {<=} 0, where A is the saturated amplitude of the marginally-stable mode; (ii) {chi} {proportional_to} {theta}{sup -{gamma}} as {theta} {yields} 0, {gamma}={gamma}{sub -}=1.020{+-}0.008 for {theta} < 0, and {gamma}={gamma}{sub +}=0.995{+-}0.020 for {theta} > 0, where {chi}={partial_derivative}A/{partial_derivative}F{sub 1} at F{sub 1} {yields} 0 is the susceptibility to external drive of the strain F{sub 1}; (iii) at {theta}=0 the system responds to external drive as A ...

2000-08-01

249

On-line dosimetry for BNCT at the MIT research reactor  

Science.gov (United States)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can ...

1996-12-31

250

On-line dosimetry for BNCT at the MIT research reactor  

International Nuclear Information System (INIS)

A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can ...

1996-11-10

251

Application of a gamma spectroscopy system to the measurement of neutron cross sections necessary to the development of nuclear energy; Mise au point d'un systeme de spectroscopie pour mesurer des sections efficaces neutroniques applicables a un possible developpement du nucleaire comme source d'energie  

Energy Technology Data Exchange (ETDEWEB)

This work concerns the development of nuclear energy and nuclear waste management in particular. Two parts of this study can be distinguished. In the first part (theoretical), a thorium-plutonium fuel based on MOX and dedicated for PWR was investigated in order to transmute plutonium in a potentially low waste fuel cycle. It was shown that this type of fuel is not regenerative but could be used for a transition to the industrial thorium fuel cycle without building new reactors. Thanks to moderated neutron spectra and high loaded actinide mass in the core, U-233 is quickly created ({approx}300 kg/y) for a loss of about {approx}1200 kg of fissile plutonium. In the second part (experimental), we have developed and built a new reaction chamber to measure neutron cross sections of actinides by alpha-gamma spectroscopy. This experimental device (in principle transportable) was commissioned in the high flux reactor of ILL Grenoble. Neutron flux was measured by ...

2002-09-01

252

Study on the angular. gamma gamma. -correlations for nuclei of Sr even-even isotopes  

Energy Technology Data Exchange (ETDEWEB)

The angular ..gamma gamma..-correlations for nuclei of Sr even-even isotopes with A=82, 84, 86, 88 were measured. Multipole structurs of ..gamma..-transtion series and th coefficients multipole mixing were determined.

1984-05-01

253

Study on the angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes  

International Nuclear Information System (INIS)

The angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes with a=8 82, 84, 86, 88 were measured. Multipole structurs of #gamma#-transtion series and th coefficients multipole mixing were determined.

1983-04-01

254

Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences  

Science.gov (United States)

The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)

1973-08-01

255

Accelerator aspects of #gamma#-#gamma# colliders  

International Nuclear Information System (INIS)

There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

256

Tests for mutagencity of free radicals formed in irradiated sugars and amino acids  

International Nuclear Information System (INIS)

Radicals formed in gamma-irradiated crystals of galactose and glycine were found, upon dissolution, to cause mutagenesis of Salmonella typhimurium strains TA-98 and TA-100. Although the reproducibility of the results has not been adequately determined, they suggest the possibility of developing a test to measure the mutagenic-carcinogenic potential of radiation-induced free radicals with a microbial system.

1977-05-01

257

Solution of Bohr's collective Hamiltonian for transitional odd-mass nuclei  

International Nuclear Information System (INIS)

A numerically feasible method, based on the use of deformed phonons, is developed for the diagonalization of the collective quadrupole Hamiltonian for a system with an odd particle coupled to an anharmonic even core. Examples: the transition from prolate to oblate via #gamma#-unstable shapes and furthermore the hsub(9/2) spectra of the nuclei "1"8"7Ir and "1"9"7Tl. (Auth.).

258

Power density distribution by gamma scanning of fuel rods measurement technique in RA-8 critical facility  

International Nuclear Information System (INIS)

Power density measurements in the critical facility RA-8 are presented. These measurements were the first systematic use of the reactor. A measurement system was designed, built and proved for this goal. Power profiles are showed and the results are compared with calculated values. (author)

1999-10-26

259

In-beam conversion electron spectroscopy using the SACRED array  

International Nuclear Information System (INIS)

Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.

260

Measuring the beam polarizations and the luminosity at photon-photon colliders  

Energy Technology Data Exchange (ETDEWEB)

We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)

1993-11-01

261

Excited leptons and quarks at. gamma. gamma. /. gamma. e colliders  

Energy Technology Data Exchange (ETDEWEB)

We discuss the search of excited leptons and quarks with spin 1/2 at {gamma}{gamma} and at {gamma}e colliders. We show that {gamma}{gamma} colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l{sup *}l{gamma} transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).

1992-02-06

262

Calibration curves of a PGNAA system for cement raw material analysis using the MCNP code  

Energy Technology Data Exchange (ETDEWEB)

In large samples, the {gamma}-ray count rate of a prompt gamma neutron activation analysis system is a multi-variable function of the elemental dry composition, density, water content and thickness of the material. The experimental calibration curves require tremendous laboratory work, using a great number of standards with well-known compositions. Although a Monte Carlo simulation study does not avoid the experimental calibration work, it reduces the number of experimental calibration standards. This paper is part of a feasibility study for a PGNAA system for on-line continuous characterisation of cement raw material conveyed on a belt (Oliveira, C., Salgado, J. and Carvalho, F. G. (1997) Optimisation of PGNAA instrument design for cement raw materials using the MCNP code. J. Radioanal. Nucl. Chem. 216(2), 191-198; Oliveira, C., Salgado, J., Goncalves, I. F., Carvalho, F. G. and Leitao, F. (1997a) A ...

1998-12-01

263

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis; Determination of optimum conditions of image processing  

Energy Technology Data Exchange (ETDEWEB)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, ...

1993-06-01

264

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis  

International Nuclear Information System (INIS)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, ...

1993-01-01

265

Modification of SGS system for application to various sized drums  

Energy Technology Data Exchange (ETDEWEB)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross {alpha} must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the ...

2005-11-15

266

Modification of SGS system for application to various sized drums  

International Nuclear Information System (INIS)

To dispose the radioactive waste drums, the waste form's integrity and the nuclides inventories must be assured according to the national and site waste acceptance criteria. Because they might be would gravely affected the performance objectives of disposal site. Our national regulation for the waste inventory related to 'Radioactive Waste Acceptance Criteria' requires that the activities of 13 nuclides and gross #alpha# must be measured and the 95 % of nuclides incorporated in the drum must be identified. It is very difficult to measure the radioactivity with accuracy from the regulated waste drum(200L), and have a large error in the analysis results. In present, there are two system, SGS (Segmented Gamma Scanning System) and TGS (Tomographic Gamma Scanning System) for the analysis of radionuclides from the waste drums. In general, it is known that the accuracy of TGS is below 20 % ...

2005-11-01

267

Demonstration and Optimization of a Drive Laser for an X-Band Photoinjector  

Energy Technology Data Exchange (ETDEWEB)

Recently, a drive laser for an S-band (2.86 GHz) rf photoinjector, designed to provide a pulse that has a flat temporal and spatial profile, has been built, commissioned, and put into service as part of the LLNL Compton-scattering monoenergetic {gamma}-ray source program. This laser is based on an all-fiber oscillator and front-end amplification system, and provides both the laser light to generate the electrons as well as the rf signal that is amplified to accelerate them. Now, a new 11.424 GHz photoinjector is being developed, which has required a revised design for the laser system. The higher frequency has placed more stringent requirements on the synchronization stability, delivered pulse length, and pulse rise times to maintain the desired emittance. Presented here are the overall design and measured performance of the current system and a discussion of what changes are being made to address ...

2009-04-17

268

Airborne lidar experiments at the Savannah River Plant, June 1985  

Energy Technology Data Exchange (ETDEWEB)

Results are presented from a series of studies conducted at the Department of Energy (DOE) Savannah River Plant (SRP) with the NASA Airborne Oceanographic Lidar (AOL). These studies included a topographic survey of a {approximately}1000 acre lake basin (presently designated L Lake) which had been excavated for use as a cooling pond for L Reactor; a study of the movement of discharged cooling water in Pond C and the warm arm of Par Pond using Rhodamine WT dye as a tag; initial baseline studies of the vegetation cover of the Steel Creek corridor (through which the outflow of L Lake is carried to the Savannah River); and a demonstration of potential forestry applications of the AOL. These investigations were conducted over a 3-day period in June 1985. The AOL is an advanced airborne laser system capable of making temporal or time history measurements of laser backscatter (bathymetry mode) or spectral measurements of laser induced fluorescence from waterborne ...

1987-09-01

269

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented. (orig.).

1985-02-01

270

Operation of a high temperature ion source at the helium-jet on-line isotope separator facility HELIOS  

Energy Technology Data Exchange (ETDEWEB)

The performance of a high temperature ion source coupled to a helium gas-jet transport system for an efficient mass separation of neutron-rich alkaline earth and lanthanide isotopes is reported and the results of overall efficiency measurements using different cluster materials in the gas-jet are given. A fast, microprocessor controlled tape transport system for ..gamma..-spectroscopic studies on short-lived isotopes is described. Some results on the decay of 3.8sub(-s) /sup 152/Pr are presented.

1985-02-01

271

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant ...

2007-08-21

272

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear power plant applications. ...

2007-08-21

273

Toward Dietary Assessment via Mobile Phone Video Cameras  

UK PubMed Central (United Kingdom)

Reliable dietary assessment is a challenging yet essential task for determining general health. Existing efforts are manual, require considerable effort, and are prone to underestimation and misrepresentation...Full Text Available

2010-01-01

274

Simple device for scanning image  

CERN Document Server

The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.

2002-01-01

275

Gendered Technoculture: Sex, Lies, Videotape & Cyberspace  

Science.gov (United States)

What happens in the matrix of gender, technology, representation, and culture? This class will explore the theoretical issues raised within this matrix. We will also make sense of the theories through practical experiences with technologies like computers and cameras.

2004-02-01

276

Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser  

International Nuclear Information System (INIS)

We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. ...

2008-04-01

277

32 CFR 813.4 - Combat camera operations.  

Science.gov (United States)

...COMCAM forces document Air Force and air component activities...supported unified command or joint task force commander, through the...Force COMCAM forces in a joint environment. If an...share of Unified Command headquarters COMCAM and visual...

2010-07-01

278

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity ...

2009-03-07

279

Study of seasonwise variations in the environmental gamma dose rates in Tarapur emergency planning zone (EPZ)  

International Nuclear Information System (INIS)

During the normal operation of a Nuclear Power Plant (NPP), radioactive releases into the atmosphere will be in small quantities. During major accidental situations, though the probability is extremely small, there may be significant release of radioactivity to the environment through the stack or at ground level. To study the external radiation exposure, if any, to the members of public due to releases during the normal operation of a nuclear power plant (NPP) and also to meet the requirement of emergency preparedness for the NPP site, continuous recording and analysis of environmental dose rate data is essential. This paper presents analysis of the gamma dose rates recorded by the Environmental Dose Logging Systems (EDLS) installed around the site during the last six years in the Emergency Planning Zone (EPZ) of Tarapur Atomic Power Station (TAPS). (author)

2005-11-23

280

Rare B decays  

Energy Technology Data Exchange (ETDEWEB)

The current status of rare B decays is reviewed based on recent observation of the penguin-diagram decay B {yields} K{sup *}{gamma} at CLEO. Rare B decays provide valuable information on the Standard Model parameters, and also could be a source of direct CP violation. It is emphasized that new physics beyond the Standard Model can appear in rare B decays, in some cases more drastically than in the CP Asymmetry of the B system. Inclusive measurement of the radiative transition b {yields} s{gamma} is promising. Hadronic penguin modes are very close to being observed at CLEO, and a discovery might be just around the corner. (author). 48 refs., 6 figs., 4 tabs.

1994-12-31

281

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the error propagation, ...

282

Instruments for X-ray fluorescence analysis and spectrometry  

International Nuclear Information System (INIS)

The radionuclide X-ray fluorescence analyzer consists of a source changer and a sample changer. "5"5Fe, "1"0"9Cd and "2"4"1Am are used as excitation sources. The radiation is detected with a semiconductor Si(Li) detector. The complete assembly of the apparatus consists of an imagine unit, a keyboard, a floppy disc drive, a printer, a console and a rack with analog and digital electronics. Its multichannel amplitude analyzer consists of power supplies, a high voltage supply, a linear amplifier, an analog-to-digital converter and a computer. The technical specifications are given. The control and data processing system is controlled with an MHB 8080A microprocessor. Software for semiconductor gamma spectrometry and for quantitative gamma spectrometry will be supplied with the equipment. (E.S.). 3 figs., 4 refs.

283

3D-nuclear heat generation in PCC-charcoal filter in TAPP-3 and 4  

International Nuclear Information System (INIS)

This paper deals with the calculations of 3D nuclear heat generation profile in the charcoal filter and subsequently the commencement time of Primary Containment Cleanup (PCC) system of 540MWe Pressurized Heavy Water Reactor (PHWR). Fuel failure is predicted due to overheating of the fuel under loss of Coolant Accident (LOCA) without Emergency Core Cooling System (LOCA without ECCS). Subsequently fission product gasses along with water vapours are released to Reactor Building (RB) atmosphere. Plate-out and water trapping mechanism stabilizes the concentration of significant fission products i.e. radioiodines in about 4 hours before being circulated through charcoal filters of Containment Cleanup system. After cleaning up the RB atmosphere, it is discharged to outside atmosphere through stack. The isotopes of radioiodine emit beta and gamma radiations. Gamma radiations are partly ...

2006-11-13

284

Preliminary Design of ARIES-Devasthal Faint Object Spectrograph and Camera  

CERN Document Server

We present here the preliminary design of ARIES-Devasthal Faint Object Spectrograph and Camera (ADFOSC), which is a multi-mode instrument for both imaging and spectroscopy. ADFOSC is the first-generation instrument to be mounted at the axial port of the Cassegrain focus on our new 3.6m optical telescope to be installed at Devasthal, Nainital. The main design goals of the instrument are : the instrument will have capability of broad- and narrow-band imaging, low-medium resolution spectroscopy, and imaging polarimetry. The operating wavelength range will be from 360 to 1000 nm and the instrument will have remote-control capability.

2009-01-01

285

Breast imaging with a dedicated PEM  

International Nuclear Information System (INIS)

During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.

2004-07-11

286

Yields of short-lived fission products produced following "2"3"5U(n_t_h,f)  

International Nuclear Information System (INIS)

Measurements of gamma-ray spectra, following the thermal neutron fission of "2"3"5U have been made using a high purity germanium detector at the University of Massachusetts Lowell (UML) Van de Graaff facility. The gamma spectra were measured at delay times ranging from 0.2 s to nearly 10000 s following the rapid transfer of the fission fragments with a helium-jet system. On the basis of the known gamma transitions, forty isotopes have been identified and studied. By measuring the relative intensities of these transitions, the relative yields of the various precursor nuclides have been calculated. The results are compared with the recommended values listed in the ENDF/B-VI fission product data base (for the lifetimes and the relative yields) and those published in the Nuclear Data Sheets (for the beta branching ratios). This information is particularly useful for the cases of short-lived fission products ...

1998-08-01

287

The measurement of the fission product ratios, {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuel by gamma scanning method  

Energy Technology Data Exchange (ETDEWEB)

We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.

1997-10-01

288

The measurement of the fission product ratios, "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuel by gamma scanning method  

International Nuclear Information System (INIS)

We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.

1988-09-18

289

The Hard X-ray Spectral Evolution in XRBs, AGNs and ULXs  

CERN Document Server

We explore the relationship between the hard X-ray photon index $\\Gamma$ and the Eddington ratio (\\xi=L_{X}(0.5-25 keV)/L_{Edd}) in six XRBs. We find that different XRBs follow different anti-correlations between $\\Gamma$ and $\\xi$ when $\\xi$ is less than a critical value, while they follow the same positive correlation when $\\xi$ is larger than the critical value. This anti-correlation and positive correlation are also found in LLAGNs and QSOs respectively, and the anti-correlation and positive correlation of different XRBs roughly converge to the same point ($\\log \\xi=-2.1, \\Gamma=1.5$), which may correspond to the accretion mode transition, since that the anti-correlation and positive correlation are consistent with the prediction of ADAFs and standard disk/corona system respectively. The traditional low/hard state are divided into two parts by the cross point $\\log \\xi\\sim-2.1$, i.e., ...

2008-01-01

290

Measurement of snow water storage in the Lake Saperior basin using aerial gamma-ray spectrometry  

International Nuclear Information System (INIS)

A pilot project was started in 1977 over the Lake Superior basin to measure water storage on the land area using aerial gamma-ray spectrometry to provide hydrologic information for forecasting inflow to the lake. Two airborne surveys were made, respectively in November 1977 and March 1978 which provided estimates of the increase in snow water equivalent between these surveys. The basin is located on the Canadian Shield and consequently, the gamma radiation count rate is quite variable. The airborne results are compared with ground measurements on selected flight lines and show generally good agreement. Two equipment calibrations in the Ottawa area provided inconsistent parameter values which are consequently also reflected in the results over the Lake Superior basin. The project has demonstrated to-date that the technique can be developed into an operational system for measuring snow cover water equivalent of this vast and ...

1977-11-01

291

#sigma#_e_e_#gamma#_#gamma#"t"o"t at e"+e"- colliders  

International Nuclear Information System (INIS)

In this talk I briefly summarize different models for #sigma#_2_#gamma#"t"o"t (e"+e"-#->##gamma##gamma##->#hadrons) and contrast model predictions with the data. I will then discuss the capability of the future e"+e"- and #gamma##gamma# colliders to distinguish between various models and end with an outlook for future work.

2001-07-09

292

Toxicological safety evaluation of biomolecules and materials transformed by gamma irradiation  

Energy Technology Data Exchange (ETDEWEB)

In the bacterial reversion assay with S. typhimurium TA98, TA100, TA1535 and TA1537, gamma irradiated hyaluronic acid (10 and 50 kGy) did not induce a significant increase in the number of revertant colonies in the presence of S9 metabolic activation system. In chromosomal aberration tests with CHO cells, gamma irradiated hyaluronic acid (10 and 50 kGy) did not result in an increase in the frequency of chromosomal aberrations. In vivo mouse micronucleus assay, gamma irradiated hyaluronic acid (10 and 50 kGy) did not show an increase in the frequency of polychromatic erythrocytes with micronuclei. These results indicate that hyaluronic acids irradiated at 10 and 50 kGy did not show any genotoxic effects under these experimental conditions. In order to evaluate their possible subacute toxicity, the male and female of ICR mouse were given to methanol extract of 50 kGy irradiated red ginseng and 20 kGy ...

2010-01-15

293

The neutron capture cross sections of {sup 237}Np(n,{gamma}) and {sup 240}Pu(n,{gamma}) and its relevance in the transmutation of nuclear waste  

Energy Technology Data Exchange (ETDEWEB)

Neutron capture cross sections of actinides are of great relevance for the Transmutation of Nuclear Waste in Accelerator Driven Systems (ADS) and Generation-IV reactors. The neutron capture cross sections of {sup 237}Np and {sup 240}Pu in the range of 1 eV to 2 keV were measured at the n-TOF facility with a Total Absorption Calorimeter. The data have been analyzed with the SAMMY code. The corresponding covariance matrices have been generated. The final cross sections are presented and compared to the previously existing ones.The n-TOF {sup 237}Np {sigma}(n,{gamma}) is in agreement with the evaluated data files below 300 eV and its is lower by 10 to 15% up to 2 keV. This discrepancy with the evaluated data files is also observed in the capture cross section derived from the transmission measurements of Gressier et al. In the case of the {sup 240}Pu {sigma}(n,{gamma}), the n-TOF {sigma}(n,{gamma}) agrees ...

2008-07-01

294

Decay of "1"0"1Mo and band structures of its daughter nuclide "1"0"1Tc in the projected shell model  

International Nuclear Information System (INIS)

The decay of molybdenum-101 has been investigated using the three-parameter (#gamma#-#gamma#-t) coincidence system of HPGe-HPGe detectors. According to the off-line analysis, the decay scheme was modified. The positions of 221.80, 318.00, 377.90; 452.50, 515.42, 1011.05, and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95, and 774.15 keV gamma rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52, and 1431.68 keV transitions have been reconfirmed, and the 1508.01 keV gamma ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#"- intensities and the values of log ft of most levels were calculated. Combining with the high-spin states observed by the in-beam #gamma#-ray spectroscopy of previous decay works, the structure of the excited ...

2006-01-01

295

Gamma-gamma collider based on Compton back-scattering  

International Nuclear Information System (INIS)

A #gamma##gamma# collider would extend and complement the physics capability of a linear collider; e.g. it would be suitable for direct measurement of the partial decay width of a Higgs boson into two gamma quanta. This paper discusses choice of laser parameters, luminosity optimization, electron and laser parameters for a gamma- gamma collider as a second interaction region for the Next Linear Collider, laser path, and the lasers. It is concluded that a gamma- gamma collider is technically feasible; however it will require a significant investment in preparatory R ampersand D.

1996-08-25

296

Chargino production at high energy {gamma}{gamma} colliders with polarized beams  

Energy Technology Data Exchange (ETDEWEB)

We investigate the chargino production process {gamma}{gamma} {yields} (W-tilde){sup +}(W-tilde){sup -} at high energy {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy {gamma} beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background {gamma}{gamma} {yields} W{sup +}W{sup -}. (author).

1995-05-01

297

Chargino production at high energy #gamma##gamma# colliders with polarized beams  

International Nuclear Information System (INIS)

We investigate the chargino production process #gamma##gamma# #-># (W-tilde)"+(W-tilde)"- at high energy #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy #gamma# beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background #gamma##gamma# #-># W"+W"-. (author).

1995-05-01

298

GAS EVOLUTION FROM INSULATING MATERIALS FOR SUPERCONDUCTING COIL OF ITER BY GAMMA RAY IRRADIATION AT LIQUID NITROGEN TEMPERATURE  

International Nuclear Information System (INIS)

A laminated material composed of glass cloth/polyimide film/epoxy resin will be used as an insulating material for superconducting coil of International Thermonuclear Experimental Reactor (ITER). In order to keep safe and stable operation of the superconducting coil system, it is indispensable to evaluate radiation resistance of the material, because the material is exposed to severe environments such as high radiation field and low temperature of 4 K. Especially, it is important to estimate the amount of gases evolved from the insulating material by irradiation, because the gases affect on the purifying system of liquid helium in the superconducting coil system. In this work, the gas evolution from the laminated material by gamma ray irradiation at liquid nitrogen temperature (77 K) was investigated, and the difference of gas evolution behavior due to difference of composition in the epoxy resin was ...

2008-03-03

299

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, ...

2009-06-07

300

A study on the radiation and environmental safety -Development of a real-time radiological dose assessment system-  

Energy Technology Data Exchange (ETDEWEB)

The real-time dose assessment system under development has been updated and the technology for tracer experiment has been established. The calculation of external gamma dose is the most difficult and time-consuming part of the dose calculations. The characteristics of external gamma exposure have been investigated and the method for reducing the calculation time has been devised. The internal exposure via the ingestion of the contaminated foodstuffs is one of the important pathways to the total radiological exposure. In the emergency, it is necessary to take an action such like food ban to protect the internal exposure. An algorithm for the interface between the real-time system and the food chain model has been provided. The second field tracer experiment over flat terrain has been carried out on a plain in Iksan city in Junrabook-Do. Sequential tracer sampler which can be sampled the tracer gas over ...

1995-07-01

301

Radwaste Drum Assay Technology by Segmented Gamma Scanning System  

Energy Technology Data Exchange (ETDEWEB)

Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated from nuclear power plants and other nuclear facilities prior to deliver to a disposal sites. Individual history records of the radioactive waste should be described the information about the activity of nuclides in the drum, total activity, weight, the type of waste. So a fully automated nuclide analysis assay system(non-destructive) of a radwaste drum was developed. For the nuclides that could not be analysed directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then the scaling factors were used to calculate the activities of {alpha} - and {beta}-emitters. This assay system divided a drum into 8 segments, a segment into 8 sectors to minimize analysis error, and used several methods(transmission ratio, differential ...

2009-01-15

302

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

Energy Technology Data Exchange (ETDEWEB)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.10{sup 11} n*cm{sup 2}/s. This facility will be based on a conical neutron collimator with ...

2009-07-01

303

Development of a neutron imaging facility at the CENM Al Maamora TRIGA  

International Nuclear Information System (INIS)

The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of the tangential channel is around 3.1011 n*cm2/s. This facility will be based on a conical neutron collimator with two ...

2009-06-07

304

gamma. /sub 5/ in dimensional regularization  

Energy Technology Data Exchange (ETDEWEB)

By generalizing the algebra satisfied by the ..gamma../sub 5/ matrix, it is possible to give an extension of ..gamma../sub 5/ to d dimensions. We discuss the connection of this scheme to others.

1985-02-07

305

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 {ell}/s (1 ft{sup 3}/min). The water flow rate was varied between 0 and 3.78 {ell}/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6} n/cm{sup 2}{center_dot}s{sup {minus}1} directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm (2-in.)-thick aluminum support plates placed on ...

1995-09-01

306

Void fraction measurements using neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. To simulate vapor conditions encountered in a fluid flow duct, an air-water flow system was constructed. Air was injected into the bottom of the duct at flow rates up to 0.47 I/s (1 cfm). The water flow rate was varied between 0--3.78 I/m (0--1 gpm). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10{sup 6}n/cm{sup 2}/s directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5 cm (2 in.) thick aluminum support plates placed on both sides of the duct wall. Image analysis techniques ...

1992-12-31

307

Void fraction measurements using neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography is being evaluated for studying the dynamic behavior of two-phase flow and for measuring void fraction in vertical and inclined water ducts. This technique provides a unique means of visualizing the behavior of fluid flow inside thick metal enclosures. An air-water flow system was constructed to simulate vapor conditions encountered in a fluid flow duct. Air was injected into the bottom of the duct at flow rates up to 0.47 ell/s (1 ft"3/min). The water flow rate was varied between 0 and 3.78 ell/min (0 to 1 gal/min). The experiments were performed at the Pennsylvania State University nuclear reactor facility using a real-time neutron radiography camera. With a thermal neutron flux on the order of 10"6 n/cm"2#centre dot#s"-"1 directed through the thin duct dimension, the dynamic behavior of the air bubbles was clearly visible through 5-cm (2-in.)-thick aluminum support plates placed on both sides of the duct wall. ...

1995-01-01

308

Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes  

International Nuclear Information System (INIS)

The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the ...

1982-06-25

309

Computer vision algorithms in DNA ploidy image analysis  

Science.gov (United States)

The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation approaches that emanate from the field of Mathematical Morphology, focusing on region-based watershed ...

2006-03-01

310

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...

2006-03-15

311

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

International Nuclear Information System (INIS)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are collected with a ...

2006-03-01

312

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section ...

1982-12-01

313

Radioprotection through cytokineliberation under N-actylcysteine; Radioprotektion durch Zytokinfreisetzung unter N-Acetylcystein  

Energy Technology Data Exchange (ETDEWEB)

Backgrund: Interleukin-1, tumornecrosisfactor-{alpha} and interferon-{gamma} endogenously provide protection of the hematopoietic system against radiation. Thiols have already been used successfully as radioprotective agents. In this study the effect von N-acetylcysteine (NAC) on the release of interleukin-1{alpha} and {beta} (IL-1), interleukin-2 (IL-2), interferon-{gamma} (IFN-{gamma}) and tumornecrosisfactor-{alpha} (TNF-{alpha}) was assessed in an in vitro assay. Patients and Methods: Whole blood samples from 8 healthy volunteers were stimulated with 7.5 {mu}m/ml PHA. NAC was added at concentrations of 0.6, 6, 12 and 24 mmol/l. Subsequently the samples were irradiated with a dose of 18 Gy according to preceding validation experiments. Results: IL-1{alpha}, IL-1{beta} and IL-2: In comparison to simulation and radiation alone the addition of 0.6 and 6 mmol/l with IL-2 also 12 mmol/l, NAC resulted in a ...

1996-02-01

314

Radiation technology, radiation technics and technological dosimetry in the Institute of Isotopes of the Hungarian Academy of Sciences. 1966-1981  

Energy Technology Data Exchange (ETDEWEB)

Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.

1982-01-01

315

Explosives detector  

Energy Technology Data Exchange (ETDEWEB)

An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, a neutron ...

1991-10-02

316

Integrated Safeguards proposal for Finland. Final report on Task FIN C 1264 of the Finnish Support Programme to IAEA Safeguards  

Energy Technology Data Exchange (ETDEWEB)

The IAEA has requested several member states to present their proposal of the application of the Integrated Safeguards (IS) system in their nuclear facilities. This report contains a IS proposal for Finland prepared under the Task FIN C 1264 of The Finnish Support Programme to IAEA Safeguards. The comprehensive safeguards system of the International Atomic Energy Agency (IAEA) has been one of the main tools in the fight against nuclear proliferation since the entry-into-force of the Nuclear Non-proliferation Treaty three decades ago. In the 1990s some of the inherent weaknesses of this so-called traditional safeguards system were revealed first in Iraq and then in North Korea. Therefore, the member states of the LAEA decided to give the Agency additional legal authority in order to make its control system more effective as well as more efficient than before. This was accomplished by the approval of the ...

2000-08-01

322

High energy photon-photon collisions  

International Nuclear Information System (INIS)

The collisions of high energy photons produced at an electron-positron collider provide a comprehensive laboratory for testing QCD, electroweak interactions, and extensions of the standard model. The luminosity and energy of the colliding photons produced by backscattering laser beams is expected to be comparable to that of the primary e"+e"- collisions. In this overview, we shall focus on tests of electroweak theory in photon-photon annihilation, particularly #gamma##gamma##->#W"+W"-, #gamma##gamma##->#Higgs bosons, and higher-order loop processes, such as #gamma##gamma##->##gamma##gamma#, Z#gamma# and ZZ. Since each photon can be resolved into a W"+W"- pair, high energy photon-photon collisions can also provide a remarkably background-free laboratory for studying WW collisions and annihilation. We also review high energy #gamma##gamma# tests of quantum chromodynamics, ...

323

Triple-vector-boson processes in [gamma][gamma] colliders  

Energy Technology Data Exchange (ETDEWEB)

We study the production of three gauge bosons ([ital W][sup +][ital W][sup [minus

1994-11-01

324

The interaction zone of a #gamma##gamma# collider at TESLA  

International Nuclear Information System (INIS)

German 2003 p. 24 Germany Klemz, G. Moenig, K. Sekaric, J. Stahl,

326

Semihard production of tensor mesons in. gamma. gamma. -collisions and the perturbative Odderon  

Energy Technology Data Exchange (ETDEWEB)

The cross sections of neutral tensor mesons T=a{sub 2}, f, f', ... production in the exclusive {gamma}{gamma}{yields}TT' or semiexclusive {gamma}{gamma}{yields}TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV{sup 2} are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future {gamma}{gamma}-colliders is discussed too. (orig.).

1992-03-01

327

Detection of the heavy Higgs boson at [gamma][gamma] colliders  

Energy Technology Data Exchange (ETDEWEB)

We consider the possibility of detecting a heavy Higgs boson ([ital m][sub [ital H

1993-07-01

328

#gamma#-#gamma# angular correlation for "1"0"1Tc transitions  

International Nuclear Information System (INIS)

... correlation beta-minus decay coincidence spectrometry experimental data

329

Using the alkoxomethod to obtain the oxide phases of Fe_2O_3-Y_2O_3 system  

International Nuclear Information System (INIS)

Production of Fe_2O_3, Y_2O_3, YFeO_3, Y_3Fe_5O_1_2 powders using the alkoxomethod - during hydrolysis by yttrium and iron alcohol solutions, is studied. It is stated that production of the powders of Y_2O_3-Fe_2O_3 system oxides using alkoxomethod permits to decrease essentially the reaction volumes, number of operations, their duration as compared to the cooxidation of oxide hydrates from inorganic salt aqueous solutions. During heat treatment of iron (3) alcohol hydrolysis products #gamma#-Fe_2O_3 is first crystallized by contrast to #alpha#-FeOOH, usually produced by deposition from solutions. Further heat treatment of #gamma#-Fe_2O_3 results in production of #alpha#-Fe_2O_3. Conditions for crystallization of Y_3Fe_5O_1_2 and YFeO_3 phases, prepared by both methods, and their crystallite mean sizes are close, but the powders obtained from alcohols are more homogeneous.

330

Improvement of wood quality used in Syria by irradiation polymerization  

International Nuclear Information System (INIS)

Wood plastic composites (WPC) have been prepared with five low-grade woods, native to Syria, and with Okoume (aucoumea klaineana pierre) imported to Syria in large quantities. Three monomer systems; acrylamide, butylmethacrylate, and styrene were used. polymerization was induced at various radiation doses (10, 20, and 30 kGy) to study the role of radiation doses using a "6"0Co gamma radiation source. Some physical properties of WPC, namely polymer loading and compression strength or tensile strength of the obtained wood polymer composites (WPC) were studied. The effect of the additives, sulfuric acid (H"+), N-vinyl pyrrolidone (NVP), trimethyolpropane triacrylate (TMPTA), urea (U), lithium nitrate (LiNo_3), copper sulfate (CuSO_4) and co-additives on monomer system polymerization were also investigated. Methanol, water and water/methanol mixtures were used as the swelling agents. In general, the use of additives and ...

2010-04-01

331

{gamma}{gamma} Cross-sections and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We summarize the predictions of different models for total {gamma}{gamma} cross-sections. The experimentally observed rise of {sigma}{sub {gamma}}{sub {gamma}} with s radical {sub {gamma}}{sub {gamma}}, faster than that for {sigma}{sub p-barp}, {sigma}{sub {gamma}}{sub p} is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of {sigma}{sub {gamma}}{sub {gamma}} with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range ...

2001-10-11

332

e#gamma# and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The results that can be expected by e#gamma# and #gamma##gamma# colliders in future are summarized. e#gamma# and #gamma##gamma# colliders have many fine possibilities, and are the economical selection for utilizing future e"+e"- colliders more effectively. e#gamma# and #gamma##gamma# colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e"+e"- collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e#gamma# and #gamma##gamma# colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e"+e"- accelerators. The production of #gamma#-beam is explained. As for the physics ...

1994-02-01

333

Top pair production in e+e- and {gamma}{gamma} processes  

Energy Technology Data Exchange (ETDEWEB)

We analyze spin correlations between top quark and anti-top quark produced at polarized e{sup +} e{sup -} and {gamma}{gamma} colliders. We consider a generic spin basis to find a strong spin correlation. Optimal spin decompositions for top quark pair are presented for e{sup +}e{sup -} and {gamma}{gamma} colliders. We show the cross- section in these bases and discuss the characteristics of results.

1998-02-01

334

Studying the triple-Higgs vertex in the process. gamma. gamma. yields HH at TeV energies  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process {gamma}{gamma}{yields}HH are calculated. It is shown that the cross section is measurable at TeV {gamma}{gamma} colliders and is marginally sensitive to the triple-Higgs variation. (orig.).

1992-06-04

335

Studying the triple-Higgs vertex in the process #gamma##gamma##->#HH at TeV energies  

International Nuclear Information System (INIS)

In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process #gamma##gamma##->#HH are calculated. It is shown that the cross section is measurable at TeV #gamma##gamma# colliders and is marginally sensitive to the triple-Higgs variation. (orig.).

336

New physics beyond the standard model at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The complementarity of e{sup +}e{sup -} and {gamma}{gamma} colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios, we concentrate in detail on signatures for Large Extra Dimensions via the process {gamma}{gamma}{yields}WW.

2001-10-11

337

New physics beyond the standard model at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The complementarity of e"+e"- and #gamma##gamma# colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios, we concentrate in detail on signatures for Large Extra Dimensions via the process #gamma##gamma##->#WW.

2001-10-11

338

New Physics Beyond the Standard Model at Gamma-Gamma Colliders  

Energy Technology Data Exchange (ETDEWEB)

The complementarity of e{sup +}e{sub {minus}} and gamma-gamma colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios the authors concentrate in detail on signatures for Large Extra Dimensions via the process gamma-gamma --> WW.

2000-08-07

339

Molecular recognition of nitrated fatty acids by PPAR[gamma  

Energy Technology Data Exchange (ETDEWEB)

Peroxisome proliferator activated receptor-{gamma} (PPAR{gamma}) regulates metabolic homeostasis and adipocyte differentiation, and it is activated by oxidized and nitrated fatty acids. Here we report the crystal structure of the PPAR{gamma} ligand binding domain bound to nitrated linoleic acid, a potent endogenous ligand of PPAR{gamma}. Structural and functional studies of receptor-ligand interactions reveal the molecular basis of PPAR{gamma} discrimination of various naturally occurring fatty acid derivatives.

2010-03-08

340

E{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The results that can be expected by e{gamma} and {gamma}{gamma} colliders in future are summarized. e{gamma} and {gamma}{gamma} colliders have many fine possibilities, and are the economical selection for utilizing future e{sup +}e{sup -} colliders more effectively. e{gamma} and {gamma}{gamma} colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e{sup +}e{sup -} collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e{gamma} and {gamma}{gamma} colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e{sup +}e{sup -} accelerators. The production of {gamma}-beam is ...

1994-02-01

341

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder positioned so that its ...

2003-03-04

342

Interim cryo-cooler/detector report  

Energy Technology Data Exchange (ETDEWEB)

This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system ...

1995-04-19

343

The design of an irradiator for the continuous processing of liquid latex  

International Nuclear Information System (INIS)

This paper presents anew design concept for a gamma irradiation plant for the continuous processing of pumpable liquids. Typical applications of such a plant include: the irradiation vulcanisation of natural latex rubber; disinfection of municipal sewage sludge for agricultural use; sterilisation of liquids in the pharmaceutical and cosmetics industries; industrial processing of bulk liquids The authors describe the design and operation of the latex irradiator now operating on a small production scale in Malaysia and proposed developments. The design allows irradiation processing to be carried out under an inert or other gaseous environment. State-of-the-art computer control system ensures the fully automatic processing operation needed by industrial computers.

1998-06-01

344

Study of d+#ALPHA# system in kinematically complete experiment at 27,2 MeV #alpha#-particle energy  

International Nuclear Information System (INIS)

The "2H(#alpha#,p#alpha#)n reaction was investigated in a kinematically complete experiment with a #alpha#-beam at energy 27.2 MeV.The "5He excited state was observed and its parameters were determinate.Coincidence spectra were fitted by contribution of sequential decay through the "5He ground and excited states.The best agreement with the data was obtained assuming the following "5He excited state parameters: E_a_n=2.8 MeV #GAMMA#=2.5 MeV.

345

Potential applications of /sup 242m/Am as a nuclear fuel  

Energy Technology Data Exchange (ETDEWEB)

The isomer /sup 242m/Am with a half-life of 141 yr. is obtained from a (n,..gamma..) capture reaction with /sup 241/Am. The latter is a decay product of /sup 241/Pu. The isomer /sup 242m/Am has the highest known thermal fission cross section. The cross sections of this isomer are evaluated. Unit cell calculations show that nuclear systems with /sup 242m/Am require less fuel by a factor of 2 to 100 compared to conventional fuels. These results indicate that potential applications of americium fuel exist, particularly for space reactors.

1988-07-01

346

FADC signal reconstruction for the MAGIC telescope  

Energy Technology Data Exchange (ETDEWEB)

Until April 2007 the Major Atmospheric Gamma ray Imaging Cherenkov (MAGIC) telescope used a 300 MSamples/s flash analog-to-digital converter (FADC) system to sample the shaped photomultiplier tube (PMT) signals produced by the captured Cherenkov photons of air showers. Different algorithms to reconstruct the signal from the read-out samples (extractors) have been implemented and are described and compared. Criteria based on the obtained charge and time resolution/bias are defined and used to judge the different extractors, by applying them to calibration, cosmic and pedestal signals. The achievable charge and time resolution have been derived as functions of the number of incident photo-electrons.

2008-09-11

347

Electrical conductivity of radiation-processed wood polymer composites  

International Nuclear Information System (INIS)

Two species of wood, viz. Haldu (Adina Cordifolia) and Jamun (Syzygium Cumini) were vacuum-impregnated with two styrene-based monomer systems and polymerized in situ with gamma radiation from a cobalt-60 source. The electrical conductivity of these specimens was determined at various polymer loadings under dry conditions, after wetting and after wet recovery as per ASTM standards. The water absorption characteristics are also presented. The results are discussed with special reference to the role of water. Potential applications are also discussed. 7 figures.

1978-01-01

348

SUSY at e{gamma}/{gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the sparticle production processes e{gamma} {yields} e tilde(Z tilde){sub 1} and {gamma}{gamma} {yields} (f tilde)(f tilde and bar) at high energy e{gamma} and {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e{gamma} colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e{gamma} {yields} (e tilde)(Z tilde){sub 1}. We show that the standard background processes e{gamma} {yields} {nu}W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e{gamma} {yields} (e ...

1994-04-01

349

SUSY at e#gamma#/#gamma##gamma# colliders  

International Nuclear Information System (INIS)

We investigate the sparticle production processes e#gamma# #-># e tilde(Z tilde)_1 and #gamma##gamma# #-># (f tilde)(f tilde and bar) at high energy e#gamma# and #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e#gamma# colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e#gamma# #-># (e tilde)(Z tilde)_1. We show that the standard background processes e#gamma# #-># #nu#W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e#gamma# #-># (e tilde)(Z tilde)_1 and ...

1994-04-01

350

Waste reduction by separation of contaminated soils during environmental restoration  

Energy Technology Data Exchange (ETDEWEB)

During cleanup of contaminated sites, Sandia National Laboratories, New Mexico (SNL/NM) frequently encounters soils with low-level radioactive contamination. The contamination is not uniformly distributed, but occurs within areas of clean soil. Because it is difficult to characterize heterogeneously contaminated soils in detail and to excavate such soils precisely using heavy equipment, it is common for large quantities of uncontaminated soil to be removed during excavation of contaminated sites. This practice results in the commingling and disposal of clean and contaminated material as low-level waste (LLW), or possibly low-level mixed waste (LLMW). Until recently, volume reduction of radioactively contaminated soil depended on manual screening and analysis of samples, which is a costly and impractical approach and does not uphold As Low As Reasonably Achievable (ALARA) principles. To reduce the amount of LLW and LLMW generated during the excavation process, SNL/NM is evaluating two ...

1998-06-01

351

Failed nuclear fuel rod analysis by gamma computed tomography  

International Nuclear Information System (INIS)

Fuel rod failures produce a release of fission products into primary coolant system. Since nuclear power plants have licensing limits for the release of volatile fission products to the environment (off-gas limits) detailed monitoring of the development of clad failure is necessary. In case of fuel rod failure a release of fission products into the primary coolant system arises. Fission gases accumulated in the free volume of a fuel rod escape through the clad defect. Water entering the fuel rod reacts with fission products, forming volatile chemical compounds. These may escape in a similar manner into the fission gases. Other compounds may dissolve and may be carried outside the fuel rod as dissolved species. Consequently, the distribution of these fission products, in the cross section of the fuel rod, is modified. An implementation of the maximum entropy gamma computed tomography technique is used to obtain such ...

352

Five-particle, shell-model calculation using a spin-dependent potential as applied to $sup 101$Tc and the nuclear decays of $sup 101$Mo, $sup 101$Tc, $sup 142$Xe, and $sup 142$Cs  

Science.gov (United States)

Thesis. Five-particle shell-model calculations, using a spin-dependent potential, were performed for the nucleus /sup 101/Tc. The effects of varying the single-particle energy differences and the strengths of the spin-dependent and pairing terms are discussed. The isobars /sup 101/Mo and /sup 101/Tc were chemically separated to enable the detailed study of their decay schemes. As a result, 184 gamma rays were observed in the decay of /sup 101/Mo, and 169 of them were assigned to 45 levels in /sup 101/Tc. In the decay of /sup 101/Tc, 27 gamma rays were observed, and 26 of them were assigned to 11 levels in /sup 101/Ru. In a study of the decays of /sup 142/Xe and /sup 142/Cs the TRI STAN on-line isotope separator was used to separate the 142 mass chain produced in /sup 235/U fission with /sup 142/2Xe as the emanating and accelerated nuclide. Isobaric separation of /sup 142/Xe and /sup 142/Cs was achieved with a ...

1974-03-01

353

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...

1989-08-15

354

Probing anomalous quartic couplings in e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We analyze the potential of the e{sup +}e{sup -} linear colliders, operating in the e{gamma} and {gamma}{gamma} modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2){sub L}(circle times)U(1){sub Y} chiral operators of order p{sup 4} that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e{gamma} and {gamma}{gamma} modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10{sup -2} at 90% C.L. Moreover, the information gathered in the e{gamma} mode can be used to reduce the ambiguities of the e{sup +}e{sup -} mode.

2001-10-01

355

Probing anomalous quartic couplings in e#gamma# and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We analyze the potential of the e"+e"- linear colliders, operating in the e#gamma# and #gamma##gamma# modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2)_L(circle times)U(1)_Y chiral operators of order p"4 that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e#gamma# and #gamma##gamma# modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10"-"2 at 90% C.L. Moreover, the information gathered in the e#gamma# mode can be used to reduce the ambiguities of the e"+e"- mode.

2001-10-01

356

The NIR Upgrade to the SALT Robert Stobie Spectrograph  

CERN Document Server

The near infrared (NIR) upgrade to the Robert Stobie Spectrograph (RSS) on the Southern African Large Telescope (SALT), RSS/NIR, extends the spectral coverage of all modes of the visible arm. The RSS/NIR is a low to medium resolution spectrograph with broadband imaging, spectropolarimetric, and Fabry-Perot imaging capabilities. The visible and NIR arms can be used simultaneously to extend spectral coverage from approximately 3200 A to 1.6 um. Both arms utilize high efficiency volume phase holographic gratings via articulating gratings and cameras. The NIR camera is designed around a 2048x2048 HAWAII-2RG detector housed in a cryogenic dewar. The Epps optical design of the camera consists of 6 spherical elements, providing sub-pixel rms image sizes of 7.5 +/- 1.0 um over all wavelengths and field angles. The exact long wavelength cutoff is yet to be determined in a detailed thermal analysis and will depend on the semi-warm ...

2006-01-01

357

Technique of moving picture overlapping for view simulation by means of the moving picture processing; Dogazo kaiseki ni motozuku keikan simulation no tame no dogazo goseiho  

Energy Technology Data Exchange (ETDEWEB)

This paper proposes a technique of moving picture overlapping for view simulation by means of the moving picture processing. The continuous pictures of actual natural view gotten from video and the pictures of building structure made by computer graphics (CG) were overlapped. The CG pictures of building structure model were made considering the camera parameters, such as position and direction of camera. In order to analyze the continuously changing camera parameters, optical flows were determined from the view video. Based on these results, the overlapping video was made, in which the building structure was incorporated into the actual view. Furthermore, the proposed technique of moving picture overlapping was applied to the view simulation of transmission line tower. Consequently, it was demonstrated that the overlapped moving pictures can provide information which can not be obtained from the still pictures. It was ...

1994-11-01

358

Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information  

International Nuclear Information System (INIS)

The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)

2010-11-01

359

Protoplanetary Disks of Binary Systems in Orion  

CERN Document Server

Dusty primordial disks surrounding young low-mass stars are revealing tracers of stellar and planetary formation. The evolution and lifetime of these disks define the boundary conditions of the mechanisms of planet formation. Stellar companions, however, can significantly change this evolution through their tidal interactions. Stellar evolution and planet formation in binaries have to respond to an environment of truncated, quickly disappearing disks--very different compared to an isolated star environment. In order to investigate details of the influence of binarity on circumstellar disk evolution, we obtained adaptive optics supported near-infrared imaging and spectroscopy of the individual components of 22 low-mass binaries in the well-known Orion Nebula Cluster. Brackett gamma emission, which we detect in several systems, is used as a tracer for the presence of an active accretion disk around each binary component. We find a low fraction of ...

2010-01-01

360

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

361

A radiation monitoring system for nuclear fusion devices  

International Nuclear Information System (INIS)

Fusion device produces high-level neutrons and #gamma#-rays, which would hazard the safety of the public and workers if the doses would be higher than the regulatory limits because of leakage from the bio-shielding and skyshine. It is essential to monitor the radiation doses in the workshop and the enumerative around fusion devices. A radiation monitoring system (RMS) for full (near and far) areas around a nuclear fusion device has been designed and developed, which can achieve the monitoring and controlling of radiation doses in the workshop area by using the Controller Area Network (CAN), in the institution area by using the Bluetooth Ad hoc network based on a new tree topology formation and routing protocol and in a long range environment by using the General Packet Radio Service (GPRS) network. (authors)

2005-12-01

362

Triple-vector-boson processes in #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study the production of three gauge bosons (W"+W"-Z"0 and W"+W"-#gamma#) at the next generation of linear e"+e"- colliders operating in the #gamma##gamma# mode. We analyze the total cross sections as well as several kinematical distributions of the final state particles. We find out that a linear e"+e"- machine operating in the #gamma##gamma# mode will produce 5--10 times more three-gauge-boson states compared to the standard e"+e"- mode at high energies.

363

Singlet scalars as Higgs imposters at the Large Hadron Collider  

CERN Document Server

An electroweak singlet scalar can couple to pairs of vector bosons through loop-induced dimension five operators. Compared to a Standard Model Higgs boson, the singlet decay widths in the diphotons and Z gamma channels are generically enhanced, while decays into massive final states like WW and ZZ are kinematically disfavored. The overall event rates into gamma gamma and Z gamma can exceed the Standard Model expectations by orders of magnitude. Such a singlet may appear as a resonant signal in the gamma gamma and Z gamma channels, even with a mass above the WW kinematic threshold.

2011-01-01

364

Probing anomalous top-quark couplings induced by dim.6 operators at photon colliders  

International Nuclear Information System (INIS)

Possible anomalous top-quark couplings induced by SU(2)xU(1) gauge-invariant dimension-6 effective operators were studied in the process of ttbar productions and decays at polarized #gamma##gamma# colliders. Two CP-violating asymmetries, a linear-polarization asymmetry and a circular-polarization asymmetry, were computed including both non-standard ttbar#gamma# and #gamma##gamma#H couplings. An optimal-observable analysis for the process #gamma##gamma##->#ttbar#->#l"#+-# was performed in order to estimate the precision for determination of all relevant non-standard couplings, including the anomalous tbW coupling.

2004-06-21

365

Corrosion resistance of #gamma#-solid solution and hardening #gamma#'-phase of nickel alloys in sodium sulfate and chloride melts  

International Nuclear Information System (INIS)

Corrosion testings of model alloys, corresponding by chemical composition to simple and complex-alloyed #gamma#- and #gamma#'-phases of nickel heat-resistant alloys are conducted in sodium sulfate and chloride melts. It is ascertained that heat resistant nickel alloys containing over 50 % of hardening #gamma#'-phase, are subject to disastrous sulfide corrosion (SC). Resistance against SC alloys containing below 50 % of #gamma#'-phase is determined by the resistance of #gamma#-solid solution. 10 refs., 3 figs., 2 tabs.

366

Time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

1992-01-01

367

Time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

1992-09-01

368

Study on the characterization of the neutron radiography facility in HANARO for two-phase flow research  

Energy Technology Data Exchange (ETDEWEB)

For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.

2001-01-01

369

Further time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 [mu]s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

1992-01-01

370

Further time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

1992-12-31

371

Target area chamber system design for the National Ignition Facility  

International Nuclear Information System (INIS)

The National Ignition Facility (NIF) is a proposed Department of Energy facility which will contribute to the resolution of important Defense Program and inertial fusion energy issues for energy production in the future. The NIF will consist of a laser system with 192 independent beamlets transported to a target chamber. The target chamber is a multi-purpose structure that provides the interface between the target and the laser optics. The chamber must be capable of achieving moderate vacuum levels in reasonable times; it must remain dimensionally stable within micron tolerances, provide support for the optics, diagnostics, and target positioner; it must minimize the debris from the x-ray and laser light environments; and it must be capable of supporting external neutron shielding. The chamber must also be fabricated from a low neutron activation material. The fusion reaction in the target gives off neutrons, x-ray and gamma rays. The x-rays ...

1994-06-19

372

Radon generation and transport in and around a gold mine tailings dam in South Africa  

Energy Technology Data Exchange (ETDEWEB)

Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the ...

2006-07-01

373

Light particle emission as a probe of the rotational degrees of freedom in deep-inelastic reactions  

International Nuclear Information System (INIS)

The emission of #alpha# particles in coincidence with the most deeply inelastic heavy-ion reactions has been studied for "1"8"1Ta + "1"6"5Ho at 1354 MeV laboratory energy and /sup nat/Ag + "8"4Kr at 664 MeV. #alpha# particle energy spectra and angular distributions, in coincidence with a projectile-like fragment, were acquired both in the reaction plane and out of the reaction plane at a fixed in-plane angle. The in-plane data for both systems are employed to show that the bulk of the #alpha# particles in coincidence with the deep-inelastic exit channel can be explained by evaporation from the fully accelerated fragments. Average velocity diagrams, #alpha#-particle energy spectra as a function of angle in several rest frames, and #alpha#-particle angular distributions are presented. The out-of-plane #alpha# particle angular distributions and the #gamma#-ray multiplicities are used to study the transfer and partitioning of angular momentum ...

374

Using Gamma-Ray Burst Prompt Emission to Probe Relativistic Shock Acceleration  

CERN Document Server

It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the significant range of spectral indices discerned in prompt burst ...

2010-01-01

375

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

Energy Technology Data Exchange (ETDEWEB)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino mass by nuclear ...

1993-12-31

376

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

International Nuclear Information System (INIS)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino mass by nuclear ...

377

Slide Rule for Rapid Response Estimation of Radiological Dose from Criticality Accidents  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a functional slide rule that provides a readily usable ?in-hand? method for estimating nuclear criticality accident information from sliding graphs, thereby permitting (1) the rapid estimation of pertinent criticality accident information without laborious or sophisticated calculations in a nuclear criticality emergency situation, (2) the appraisal of potential fission yields and external personnel radiation exposures for facility safety analyses, and (3) a technical basis for emergency preparedness and training programs at nonreactor nuclear facilities. The slide rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, distance from the fission source, and time-after criticality accidents for five different critical systems. Another sliding graph permits the estimation of critical solution fission yields based upon fissile material concentration, critical vessel ...

1999-09-20

378

Radiation processed sawdust-clay-plastic composite. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Wood sawdust has been applied to manufacture the sawdust-clay-plastic composite (SDCPC) by radiation process for the purpose of disposing large amount of wood sawdust waste material. The process comprises the impregnation of liquid vinyl monomers into the completely dried molded sawdust-clay specimens followed by exposure to Co-60 gamma-radiation to induce graft-copolymerization of the impregnated vinyl monomers onto the sawdust-clay matrix. The comonomer system of unsaturated polyester and vinyl compounds was found to be the ideal impregnating monomer for the preparation of the SDCPC from the viewpoint of the technological and economical advantages. The SDCPC material has a variety of the sawdust content which enables the composite to have wide range of mechanical properties, e.g., 410 to 1100 kg/cm/sup 2/ in compressive strength, 120 to 380 kg/cm/sup 2/ in tensile strength and 0.32 to 4.41 kg/mm/sup 2/ in static bending strength. The SDCPC ...

1983-01-01

379

Production of wood plastic properties using gamma radiation as a polimerization agent  

International Nuclear Information System (INIS)

The properties of wood plastic composites (WPC) based on Pinus Radiata D. Don impregnated with methylmethacrylate and subsequently polymerized with gamma radiation were studied. Different systems of impregnation were utilized, in order to obtain partial and shell loads. The minimum irradiation dose uses was 16 kGy. The following tests were made to the material: static bending, compression strenght parallel to grain, hardness, sheer strength, toughness, water absorption, dimensional stability and flame propagation index. To evaluate the testing, the results of the samples were separated according final density in the ranges: R_1 = 429-483 kg/m3 (without treatment); R_2 = 500-650 kg/m3 and R3 = 651-850 kg/m3. In general, the best results were obtained for samples of high density. The most important results were achieved for dimensional stability, water absorption and hardness. (Author).

1984-01-01

380

Organisms posses enzymes that function in the repair of DNA damaged by radiations, chemicals and metabolic events  

International Nuclear Information System (INIS)

This report briefly describes the studies on the mechanism of in vivo DNA repairing by the author in Research Reactor Institute, Kyoto Univ. for the past 30 years. First, the ability of UV radiation to induce transformation was investigated with viral DNA. The formation of thymine-thymine dimer was found harmful to organisms and such dimers were removable by UV-radiation at a low frequency. The mutability was determined in three different E.coli strains with mutator gene, mutT, mutS or mutL. The ability to excise 8-oxoguanin developed in primer DNA was deficient in mutT and miss-pairing left after DNA replication could not be recovered in mutL and mutS strains. Further, DNA repairing mechanism was investigated in other microorganisms; single-strand cleavage caused by exposure to BNCB radiation (boron-neutron-captured beam) could not be repaired in E. coli. Whereas for Deinococcus radiodurans, of which survival rate was not decreased by #gamma#-ray radiation at 5 ...

1998-01-01

381

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of experiments. Real time radio-imagers ({beta}-imager and {mu}-imager) are preferred to ...

2007-04-15

382

Evidence of polarisation in the prompt gamma-ray emission from GRB 930131 and GRB 960924  

CERN Document Server

The true nature of the progenitor to GRBs remains elusive; one characteristic that would constrain our understanding of the GRB mechanism considerably is gamma-ray polarimetry measurements of the initial burst flux. We present a method that interprets the prompt GRB flux as it Compton scatters off the Earth's atmosphere, based on detailed modelling of both the Earth's atmosphere and the orbiting detectors. The BATSE mission aboard the \\textit{CGRO} monitored the whole sky in the 20 keV - 1 MeV energy band continuously from April 1991 until June 2000. We present the BATSE Albedo Polarimetry System (BAPS), and show that GRB 930131 and GRB 960924 provide evidence of polarisation in their prompt flux that is consistent with degrees of polarisation of $\\Pi>35$% and $\\Pi>50$% respectively. While the evidence of polarisation is strong, the method is unable to strongly constrain the degree of polarisation beyond a systematics based estimation. ...

2005-01-01

383

Determination of americium in plutonium based nuclear fuel materials: An assessment of different methodologies  

International Nuclear Information System (INIS)

Determination of americium (Am) is one of the requirements of chemical quality assurance of plutonium (Pu) bearing fuel materials. Though many methods are published for determining Am at picogram to femtogram levels in environmental and biological matrices, yet a few of them are used routinely for Pu based nuclear fuel samples. This paper gives a brief summary of the different analytical methods available and presents results of our experiments on the determination of Am in Pu bearing fuels using gamma spectroscopy. The methods utilizing gamma emissions from "2"4"1Am and Pu isotopes are fast as they do not involve chemical separation of Pu and Am, do not require an accurate knowledge of the efficiency values of the detector systems and are not dependent on the availability of a radiometric standard for "2"4"1Am. In addition, for aged Pu samples containing large amounts of "2"4"1Am, there is no need for dilution and this ...

2010-11-15

384

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose Equivalent ...

1988-10-01

385

Assay of the uranium and plutonium content in process residues and wastes using the correction for sample self attenuation in segmented gamma scanning system  

International Nuclear Information System (INIS)

A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurement results is also studied. The measurement results of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The uncertainty of measurement results for uranium and plutonium content in process residues and wastes is 5% with 68.3% of confidence level

1998-09-01

386

#beta#-delayed proton decays near the proton drip line  

International Nuclear Information System (INIS)

In order to improve the measuring efficiency, a 'proton-gamma' coincidence technique in combination with a He-jet tape transport system was proposed and employed to identify the #beta#-delayed proton precursors. The study of #beta#-delayed proton decays near the proton drip line by using the 'proton-gamma' coincidence technique over the last 5 years at the Institute of Modern Physics, Lanzhou, China, was summarized. New #beta#-delayed proton precursors "1"2"1Ce, "1"2"5Nd, "1"2"8Pm, "1"2"9Sm, "1"3"5Gd, "1"3"7Gd, "1"3"9Dy, "1"4"2Ho, and "1"4"9Yb in the rare-earth region along a speculated proton drip line were synthesized and identified for the first time. The #beta#-delayed proton decays of "8"1Zr, "8"5Mo, "8"9Ru, and "9"3Pd in T_z=1/2 series as well as "9"2Rh in T_z=1 series were observed.

2002-04-02

387

Single dilepton production at e"+e"-, e#gamma#, and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We calculate the cross sections for the single production of doubly charged dileptons, both scalar and vector, at e"+e"-, e#gamma#, and #gamma##gamma# colliders at #sq root#s =500 GeV and 1 TeV. The e#gamma# mode is by far the most promising---dileptons whose coupling is as weak as #approx#10"-"4#alpha#_e_m can be observed, for masses virtually up to the kinematic limit. Dileptons of mass up to #sq root#s can also be seen in e"+e"- and #gamma##gamma# colliders, for couplings of order #alpha#_e_m. In all three colliders, most of the cross section comes from events in which the only particles detected are e"-e"- (or #mu#"-#mu#"- or #tau#"-#tau#"-), the decay products of the dilepton, yielding an unmistakable experimental signature.

388

Single charged top-pion production at next generation #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The future e"+e"- linear colliders can also operate in the e#gamma# or #gamma##gamma# modes. In the context of the top-color assisted technicolor (TC2) model, we study the single charged top-pion production process #gamma##gamma# #-># tb-bar#PI#_t"-. The results show that the production rates can reach the level of tens fb with reasonable parameter values. So one can expect that enough signals could be produced in future high-energy linear collider experiments. Furthermore, the flavor-changing (FC) decay mode #PI#_t"- #-># bc-bar is the best channel to detect the charged top pion due to the clean standard model background. With a large number of events and the clean background, the charged top pion should be observable at future linear colliders operating in #gamma##gamma# mode at the TeV energy scale

2008-09-01

389

Optimal beam polarizations for new-physics search through {gamma}{gamma}{yields}t t-bar {yields}lX/bX  

Energy Technology Data Exchange (ETDEWEB)

We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in {gamma}{gamma}{yields}t t-bar {yields}lX/bX for various beam polarizations in order to study possible anomalous t t-bar {gamma}, tbW and {gamma}{gamma}H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and {gamma}{gamma} colliders from the viewpoint of the anomalous-top-quark-coupling determination.

2005-11-15

390

Optimal beam polarizations for new-physics search through #gamma##gamma##->#t t-bar #->#lX/bX  

International Nuclear Information System (INIS)

We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in #gamma##gamma##->#t t-bar #->#lX/bX for various beam polarizations in order to study possible anomalous t t-bar #gamma#, tbW and #gamma##gamma#H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and #gamma##gamma# colliders from the viewpoint of the anomalous-top-quark-coupling determination.

2005-11-01

391

Atom-probe field-ion microscopy investigation of CMSX-4 Ni-base superalloy laser beam welds  

Energy Technology Data Exchange (ETDEWEB)

CMSX-4 superalloy laser beam welds were investigated by transmission electron microscopy and atom probe field-ion microscopy (APFIM). The weld microstructure consisted of fine (10- to 50-nm) irregularly shaped {gamma}` precipitates (0.65 to 0.75 volume fraction) within the {gamma} matrix. APFIM compositions of the {gamma} and {gamma}` phases were found to be different from those in the base metal. Concentration profiles across the {gamma} and {gamma}` phases showed extensive variations of Cr, Co and Al concentrations as a function of distance within the {gamma} phase. Calculated lattice misfits near the {gamma}/{gamma}` interface in the welds are positive values compared to the negative values for base metal. (orig.).

1996-09-01

392

Anomalous g_5"Z coupling at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study the constraints on the anomalous coupling g_5"Z that can be obtained from the analysis of the reaction #gamma##gamma##->#W"+W"-Z at future linear e"+e"- colliders. We find out that a 0.5 (1) TeV e"+e"- collider operating in the #gamma##gamma# mode can probe values of g_5"Z of the order of 0.15 (4.5x10"-"2) for an integrated luminosity of 10 fb"-"1. This shows that the ability to search for this anomalous interaction of the #gamma##gamma# mode is better than the one of the usual e"+e"- mode, and it is similar to the ability of the e#gamma# mode.

393

Target Diagnostic Instrument-Based Controls Framework for the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

NIF target diagnostics are being developed to observe and measure the extreme physics of targets irradiated by the 192-beam laser. The response time of target materials can be on the order of 100ps--the time it takes light to travel 3 cm--temperatures more than 100 times hotter than the surface of the sun, and pressures that exceed 109 atmospheres. Optical and x-ray diagnostics were developed and fielded to observe and record the results of the first 4-beam experiments at NIF. Hard and soft x-ray spectra were measured, and time-integrated and gated x-ray images of hydrodynamics experiments were recorded. Optical diagnostics recorded backscatter from the target, and VISAR laser velocimetry measurements were taken of laser-shocked target surfaces. Additional diagnostics are being developed and commissioned to observe and diagnose ignition implosions, including various neutron and activation diagnostics. NIF's diagnostics are being developed at LLNL and with collaborators at ...

2007-05-07

394

Accelerator aspects of {gamma}-{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

395

Gamma-ray pulse height spectrum analysis on systems with multiple Ge detectors using a spectrum summing  

Energy Technology Data Exchange (ETDEWEB)

A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for the total waste ...

1997-05-01

396

The scintigraphy of the brain: development, methods and present consequence  

International Nuclear Information System (INIS)

Brain scintiscanning which was first carried out exclusively 'statical' and only with test substances of limited quality has been replaced nowadays by 'dynamical' camera-sequency-scintiscanning with technetium. This brought considerable progress not only for identifying but also for the differential diagnosis of cerebro-organic processes. Development, methods, and integration of brain scintiscanning in a diagnostical conception are described briefly. (orig.).

397

Teleobservation in hostile environment  

International Nuclear Information System (INIS)

In order to meet the needs of remote servicing performed in nuclear power plants, in fuel reprocessing plants and in atomic research centers three companies: - STMI, subsidiary of CEA, EDF and SGN, specialized in decontamination and dismantling, - La Calhene, subsidiary of CEA and SGN, specialized in robotics, - Inspectronic, manufacturer of closed circuit television cameras, have combined to create the Visionic Society, the main objectives of which are observation by television and inspections in radioactive environment.

398

Solar Eclipse Images - SDAC Home Page - NASA  

Science.gov (United States)

Oct 24, 1995 ... The photos were made with a Nikon FE and a Sigma 400mm APO f/5.6 lens ... Note: The JPEG images to which the above links point contain subtle ... India on 1995 October 24 with a digital camera and Fe X 6374 ? filter, ...

399

CORONAL OBSERVATIONS OF CMEs Report of Working Group A  

Science.gov (United States)

imaging of the solar corona began in 1960 via a primitive pinhole camera on a ... IR wavelengths. Such data help us to study in detail the pre-eruptive ...... Schematic picture of flare loops, CME, and the current sheet between ..... As part of NASA's Living With a Star (LWS) program the planned Sentinel mission ...

400

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and the variations in ...

1984-06-05

401

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

402

\\psi(2S) Decays into $\\J$ plus Two Photons  

CERN Document Server

Using $\\gamma \\gamma J/\\psi, J/\\psi \\ra e^+ e^-$ and $\\mu^+ \\mu^-$ events from a sample of $14.0\\times 10^6$ $\\psip$ decays collected with the BESII detector, the branching fractions for $\\psip\\ra \\pi^0\\J$, $\\eta\\J$, and $\\psi(2S)\\ar\\gamma\\chi_{c1},\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi$ are measured to be $B(\\psip\\ra \\pi^0\\J) = (1.43\\pm0.14\\pm0.13)\\times 10^{-3}$, $B(\\psip\\ra \\eta\\J) = (2.98\\pm0.09\\pm0.23)%$, $B(\\psi(2S)\\ar\\gamma\\chi_{c1}\\ar\\gamma\\gamma\\jpsi) = (2.81\\pm0.05\\pm 0.23)%$, and $B(\\psi(2S)\\ar\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi) = (1.62\\pm0.04\\pm 0.12)%$.

2004-01-01

403

Role of interferon-gamma in interleukin 12-induced pathology in mice.  

UK PubMed Central (United Kingdom)

Interleukin 12 (IL-12) activates natural killer (NK) and T cells with the secondary synthesis and release of interferon-gamma (IFN-gamma) and other cytokines. IL-12-induced organ alterations are reported...Full Text Available

1995-12-01

404

Response of heifer mammary gland macrophages and neutrophils to interferon-gamma stimulation in vitro.  

UK PubMed Central (United Kingdom)

The phagocytic and killing abilities of heifer mammary gland macrophages (M phi) and neutrophils were evaluated after exposure to recombinant bovine interferon-gamma (rBoIFN-gamma) stimulation in vitro....Full Text Available

1993-07-01

405

On the decay of "2"0"3Bi  

International Nuclear Information System (INIS)

The radioactive decay of "2"0"3Bi is studied. A level scheme is proposed for "2"0"3Pb on the basis of #gamma#-ray and electron spectra and #gamma#-#gamma# coincidence measurements. The experimental data are compared with theoretical results obtained in a three quasiparticle approximation. (Auth.).

406

Measurements of the CKM angle $\\gamma/\\phi_{3}$ at B-factories  

CERN Document Server

The CKM angle $\\gamma/\\phi_{3}$ had been measured by two B-factories, the PEPII collider for the BaBar experiment and the KEKB collider for the Belle experiments. The present paper reports recent progress in $\\gamma/\\phi_{3}$.

2011-01-01

407

Isolation and characterization of a novel gamma-hexachlorocyclohexane-degrading bacterium.  

UK PubMed Central (United Kingdom)

The natural biotic capacity of soils to degrade gamma-hexachlorocyclohexane (gamma-HCH, lindane) was estimated using an enrichment technique based on the ability of soil bacteria to develop on synthetic...Full Text Available

1996-10-01

408

Cloning and sequencing of a dehalogenase gene encoding an enzyme with hydrolase activity involved in the degradation of gamma-hexachlorocyclohexane in Pseudomonas paucimobilis.  

UK PubMed Central (United Kingdom)

In Pseudomonas paucimobilis UT26, gamma-hexachlorocyclohexane (gamma-HCH) is converted by two steps of dehydrochlorination to a chemically unstable intermediate, 1,3,4,6-tetrachloro-1,4-cyclohexadiene...Full Text Available

1993-10-01

409

Pair production of charged top-pions in the $\\gamma\\gamma$ collisions at the ILC  

CERN Document Server

The top-color assisted technicolor (TC2) mode predicts the existence of a pair of charged top-pions $\\pi^{\\pm}_t$. In this paper, we study the production of the charged top-pions pair $\\pi^{\\pm}_t$ at next generation $\\gamma\\gamma$ colliders. The results show that the production rates can reach the level of $10^2$ fb with reasonable parameter space. With a large number of events and the clean background, the charged top-pion should be observable at the $\\gamma\\gamma$ colliders. Therefore, our studies can help us to search for charged top-pion, and furthermore, to test the TC2 model.

2011-01-01

410

Intermediate mass Higgs study at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

411

Intermediate mass Higgs study at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

412

Heavy quark production in $\\gamma\\gamma$ collisions a theoretical reappraisal  

CERN Document Server

Heavy quark production in $\\gamma\\gamma$ collisions is analyzed within the approach to hard collisions of photons recently proposed by the author. In this approach evaluating the cross section $\\sigma(\\gamma\\gamma\\to Q\\bar{Q})$ in the ``next-to-leading order of QCD'' requires the inclusion of direct photon contributions up to the order $\\alpha^2\\alpha_s^2$, whereas in the standard approach direct photon terms only up to the order $\\alpha^2\\alpha_s$ are taken into account. Phenomenological consequences of this difference are discussed.

2000-01-01

413

Understanding the peak asymmetry in alpha liquid scintillation with {beta}/{gamma} discrimination  

Energy Technology Data Exchange (ETDEWEB)

The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for odd-even nuclides, but ...

2000-07-01

414

Status of lead and bismuth for radioimmunoimaging and radioimmunotherapy  

International Nuclear Information System (INIS)

Tumor-targeted monoclonal antibodies (mAb) might be useful as diagnostic or therapeutic agents when linked to cytotoxic or imaging reagents. Our group is working to test this hypothesis by linking cytocidal and image-producing isotopes to mAb and testing the utility of the radioimmunoconjugates formed in animal model systems. Radioiodines were first employed for these purposes,but unfavorable nuclear properties (half-lives, #gamma#-ray and #beta#-particle energies) and chemical reactivity (deiodination in vivo) limit their utility. Labeling immunoproteins with metallic radionuclides offers more versatility in that the selection of potentially useful radiometals spans the periodic table.Of the metallic radionuclides with physical properties most suited for use with mAb in nuclear medicine, few are more available or desirable than those of bismuth ("2"1"2Bi) and lead ("2"0"3Pb, "2"1"2Pb), as listed in Table 1. "2"1"2Bi or "2"1"2Pb could serve as ...

1990-08-26

415

Role of CeO{sub 2} in Ni/CeO{sub 2}-Al{sub 2}O{sub 3} catalysts for carbon dioxide reforming of methane  

Energy Technology Data Exchange (ETDEWEB)

Ni catalysts supported on {gamma}-Al{sub 2}O{sub 3}, CeO{sub 2} and CeO{sub 2}-Al{sub 2}O{sub 3} systems were tested for catalytic CO{sub 2} reforming of methane into synthesis gas. Ni/CeO{sub 2}-Al{sub 2}O{sub 3} catalysts showed much better catalytic performance than either CeO{sub 2}- or {gamma}-Al{sub 2}O{sub 3}-supported Ni catalysts. CeO{sub 2} as a support for Ni catalysts produced a strong metal-support interaction (SMSI), which reduced the catalytic activity and carbon deposition. However, CeO{sub 2} had positive effect on catalytic activity, stability, and carbon suppression when used as a promoter in Ni/{gamma}-Al{sub 2}O{sub 3} catalysts for this reaction. A weight loading of 1-5wt% CeO{sub 2} was found to be the optimum. Ni catalysts with CeO{sub 2} promoters reduced the chemical interaction between nickel and support, resulting in an increase in reducibility and stronger dispersion of ...

1998-12-07

416

Large sample NAA facility at GRR-1 research reactor: Design and applications  

International Nuclear Information System (INIS)

Full text: A Large Sample Neutron Activation Analysis (LSNAA) facility is under development at GRR-1 research reactor, NCSR 'Demokritos'. The LSNAA facility design incorporates sample irradiation in the reactor's graphite thermal neutron column and subsequent measurement of the activity induced at a gamma spectroscopy system with gamma ray transmission measurement options included. Monte Carlo neutron and photon transport code MCNP-4C was used to model the facility. Appropriate correction factors accounting for neutron field perturbation during sample irradiation, high purity germanium detector efficiency for the volume source and gamma ray self-absorption within the sample itself were derived. The results of the computations were experimentally verified by activation foil measurements for a set of known materials and a range of sample sizes extending up to 10 litters. Moreover, the special issue of ...

2003-06-09

417

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation ...

1995-11-01

418

Semihard production of neutral pseudoscalar and tensor mesons in photon-photon collisions  

Energy Technology Data Exchange (ETDEWEB)

We investigate the semihard production of neutral pseudoscalar and tensor mesons in high-energy [gamma][gamma] collisions (M=P=[pi][sup 0], [eta], [eta]' or M=T=a[sub 2], f[sub 2], f[sub 2]'). We deal with the exclusive [gamma][gamma][yields]MM' or semi-exclusive [gamma][gamma][yields]MX reactions (X is the hadron jet with not too large mass). The considered transfer momenta are small in comparison with the photon energies and they are large in comparison with the confinement scale. The amplitudes of these processes are determined by the odderon exchange, i.e. three-gluon exchange in the lowest order of perturbative QCD. The cross sections are calculated in this approximation. The possibility of measurements at LEP and at future [gamma][gamma] colliders is discussed. (orig.).

1992-12-21

419

Radiation deamination of tetracycline. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.

1980-01-01

420

Production of doubly charged vector bilepton pairs at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The production of pairs of doubly charged vector bileptons is studied at future #gamma##gamma# colliders. The unpolarized cross section for the #gamma##gamma##->#Y"-"-Y"+"+ subprocess is analytically calculated and convoluted to predict the number of events in the complete e"+e"-#->##gamma##gamma##->#Y"-"-Y"+"+ process. The gauge or nongauge character of the vector bilepton Y"#+-#"#+-# is discussed. It is found that, as a consequence of its spectacular signature, as it decays dominantly into two identical charged leptons, and also due to its charge contents, which significantly enhance the cross section, the detection of this class of particles with mass in the sub-TeV region can be at the reach of these colliders. The model-independent nature of our results is stressed.

2006-05-01

421

On penetration effect in M1 component of 70.45 keV #gamma#-transition in "1"7"7Ta  

International Nuclear Information System (INIS)

... gamma radiation l conversion m conversion mev range 10-100 mixing ratio

1987-04-14

422

Il package software GESIS per la gestione di sistemi spettrometrici gamma  

CERN Document Server

Il package software GESIS per la gestione di sistemi spettrometrici gamma

1986-01-01

423

Gamma-spectroscopy of "6"4Mn_3_9 and "6"6Mn_4_1 decays  

International Nuclear Information System (INIS)

... v. 33(4). beta-minus decay de-excitation delayed gamma radiation iron 64

424

Gamma-absorption identification of substance  

International Nuclear Information System (INIS)

The possibility of gamma-absorption identification of the analyzed substance is considered. the basic provisions of the proposed method are concentrated on the example of carbohydrates and hydrocarbons. The above method is tested experimentally on polyethylenes and polystyrene

425

GAMMA SPECTRA AND PERIODS OF FOUR ODD-A ISOTOPES OF TUNGSTEN AND TANTALUM  

Science.gov (United States)

The gamma spectra and lifetimes of the Ta and W isotopes havimg mass numbers 173, 175, 177, and 179 are determined. (T.F.H.)

1963-06-01

426

Evaluation of surgical gamma probes for sentinel node localisation in cervical and vulvar cancer  

International Nuclear Information System (INIS)

Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and limitations should be ...

428

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

429

Comparison of the BUGLE-80 and SAILOR libraries for coupled neutron-gamma transport applications  

International Nuclear Information System (INIS)

The coupled neutron-gamma cross section libraries BUGLE-80 and SAILOR are compared, with focus on gamma production and transport and its sensitivity to the thermal component of the neutron flux. In addition, the importance of the prompt versus delayed components of the gamma source is addressed. Although BUGLE-80 shows some discrepancies in the core region, the two libraries demonstrate similar capability in the vicinity of the pressure vessel and beyond. The delayed fission product gammas from the core have little impact on the local gamma fluxes beyond the pressure vessel. Although thermal neutron capture is the dominant component of the gamma source, there is little sensitivity of the gamma source to uncertainties in the thermal neutron cross sections, due to compensating effects which tend to keep the thermal neutron capture rate ...

432

Status of the WAND (Waste Assay for Nonradioactive Disposal) project as of July 1997  

Energy Technology Data Exchange (ETDEWEB)

The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. ...

1998-03-01

433

FFTF [Fast Flux Test Facility] Fission Gas Monitor Computer System  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled, fast neutron test reactor located on the Hanford Site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The Fission Gas Monitor System (FGMS) integrates commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows either system A or B to be taken ...

434

Tissue equivalent proportional counter real time neutron monitor  

International Nuclear Information System (INIS)

The Tissue Equivalent Proportional Counter (TEPC) was developed to monitor low level neutron exposure rates at working stations in a nuclear fuel fabrication facility. It has proven capable of accurately measuring neutron dose rates at levels from 0.1 to 0.2 mrem/hr. It also calculates the Quality Factor which is of importance in locations where the neutron to gamma ratio may vary significantly and irregularily. The system described is computerized to monitor 100 work locations simulationeously and can be expanded to monitor 384 locations. Neutron dose is accumulated on a real time basis and after the proton drop point is established, dose rate can be read out at any time for the dose accumulated over a specified period of time. The current development program which provides reduced system maintenance, lower detection limits, and improved accuracy is discussed along with examples of measurement data and work experience with ...

1978-10-25

435

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average value of the void ...

1992-11-12

436

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter measurements. For neutron activation analysis and ...

1994-09-01

437

Impact of radiation measurements on hardening of TFTR diagnostics  

International Nuclear Information System (INIS)

Contrary to previous plans for the preparation of diagnostic systems for D-T break-even experiments in the Tokamak Fusion Test Reactor (TFTR), it now appears that a limited Q#approx#1 demonstration can be carried out without constructing a close-fitting igloo radiation shield around the tokamak. In order to assess the impact of D-T operation of TFTR without an igloo shield, particularly with regard to hardening of diagonstic systems, we have mapped neutron and gamma fluxes inside the test cell and test cell basement, using a variety of radiation measurements. The measurements are sufficiently detailed to resolve massive hardware components, such as neutral beams and shielded diagnostic systems, and can be used to predict local fluxes. By comparing the measurements with transport code calculations for the case of a bare tokamak, we conclude that the models have substantially overestimated fluxes both ...

438

Boron-Lined Neutron Detector Measurements  

Energy Technology Data Exchange (ETDEWEB)

Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed boron-lined proportional counter option. ...

2009-11-02

439

THE EVOLUTION OF LYMAN LIMIT ABSORPTION SYSTEMS TO REDSHIFT SIX  

International Nuclear Information System (INIS)

We have measured the redshift evolution of the density of Lyman limit systems (LLSs) in the intergalactic medium over the redshift range 0 < z < 6. We have used two new quasar samples to (1) improve coverage at z #approx# 1, with GALEX grism spectrograph observations of 50 quasars with 0.8 < z_e_m < 1.3, and (2) extend coverage to z #approx# 6, with Keck ESI spectra of 25 quasars with 4.17 < z_e_m < 5.99. Using these samples together with published data, we find that the number density of LLS per unit redshift, n(z), can be well fit by a simple evolution of the form n(z) = n_3_._5[(1 + z)/4.5]"#gamma# with n_3_._5 = 2.80 #+-# 0.33 and #gamma# = 1.94"+"0"."3"6_-_0_._3_2 for the entire range 0 < z < 6. We have also reanalyzed the evolution of damped Ly#alpha# systems (DLAs) in the redshift range 4 < z < 5 using our high-redshift quasar sample. We find a total of 17 DLAs and ...

2010-10-01

440

Development of a Computer Program for the Integrated Control of the Fuel Homogeneity Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The computer program is developed based on Visual C++, which is equipped with a user-friendly interface of the input/output(I/O) and a display function for the measuring conditions. This program consists of three parts which are the port communication, PLC(Programmable Logic Controller) and the MCA(Multi Channel Analyzer) control parts. The communication type between the CPU of the PLC module box and the computer is selected as be the Rs-232 asynchronous type and the thread method is adapted in the development of the first part of the program. The PLC-related program has been developed so that the data communication between the PLC CPU and the computer could be harmonized with the unique commands which have already been defined in the PLC. The measuring space and time intervals, the start and end ROI(region of interest) values, and the allowable error limitation are input at each measurement in this program. Finally the controlling MCA program has been developed by using ...

2005-11-15

441

Contribution \\`{a} l'etude des binaires des types F, G, K, M IX. HD 191588, nouvelle binaire spectroscopique \\`{a} raies simples de type RS Cvn, systeme triple  

CERN Document Server

An accident of misidentification has brought to light the interesting system HD 191588, a new RS CVn-type spectroscopic binary. A radial-velocity study of the primary star, the only seen component, carried out at the Observatoire de Haute-Provence with the Coravel instrument and subsequently at the Cambridge Observatories with a similar one, reveals two orbital motions: a short-period orbit (60 days) and a long-period one (about 4.5 years), so this star is a triple system. The following orbital elements are obtained: (1) for the long-period orbit P = 1667+/-17 days, T = 50901 +/-67 MJD, Gamma = +2.09 +/-0.07 km/s, K = 2.51 +/-0.13 km/s, e = 0.18 +/-0.04, omega = 228deg +/- 14 deg, a1 sin i = 56.7 +/- 3.0 Gm, f(m) = 0.0026 +/-0.0004 M_sun, and (2) for the short-period orbit P = 60.0269 +/-0.0016 days, T = 50482.6 +/-3.3 MJD, gamma is var., K = 24.03 +/- 0.09 km/s, e = 0.012 +/-0.004, omega = 233 deg ...

2003-01-01

442

Comparisons of Monte Carlo calculations with absorbed dose determinations in flat materials using high-current, energetic electron beams  

International Nuclear Information System (INIS)

International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex ...

2007-08-01

443

APSTNG: Neutron interrogation for detection of nuclear and CW weapons, explosives, and drugs  

Energy Technology Data Exchange (ETDEWEB)

A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image ...

1992-07-01

444

A comparison of tectonic and eustatic control on Maastrichtian depositional sequences, south-central Wyoming  

Energy Technology Data Exchange (ETDEWEB)

Timing and geometry of Maastrichtian third-order sequences and systems tracts of south-central Wyoming were mostly controlled by rapid basin subsidence resulting from thrust loading of foreland basin crust. The basement of the Red Desert/Washakie basin was affected by thrusting in the Sevier belt to the west and by thrusting along the edge of the Wind River Mountains and Granite Mountains. A transgressive systems tract consists of the youngest Ericson Formation above a regional unconformity, backstepping Almond Formation nearshore and nonmarine facies, and shelfal mudstones of the lower Lewis Shale. Regionally, the onset of transgression is younger from east to west, beginning at 71.5 Ma in eastern Wyoming and at 70.5-71 Ma in south-central Wyoming. The transgression culminated in a condensed shale section evident on gamma-ray logs that occurs throughout the basin. Above the gamma-ray zone, the ...

1990-05-01

445

Use of shell model calculations in R-matrix studies of neutron-induced reactions  

Energy Technology Data Exchange (ETDEWEB)

R-matrix analyses of neutron-induced reactions for many of the lightest p-shell nuclei are difficult due to a lack of distinct resonance structure in the reaction cross sections. Initial values for the required R-matrix parameters, E,sub(lambda) and ..gamma..sub(lambdac) for states in the compound system, can be obtained from shell model calculations. In the present work, the results of recent shell model calculations for the lithium isotopes have been used in R-matrix analyses of /sup 6/Li+n and /sup 7/Li+n reactions for E sub(n) < 8 MeV. Consequences of the shell model predictions for the level structure of /sup 7/Li and /sup 8/Li on the /sup 6/Li+n and /sup 7/Li+n reaction mechanisms and cross sections are discussed.

1986-01-01

446

Upper Limits from HESS Observations of AGN in 2005-2007  

CERN Document Server

Very high energy (VHE; >100 GeV) observations of a sample of selected active galactic nuclei (AGN) were performed between January 2005 and April 2007 with the High Energy Stereoscopic System (HESS), an array of imaging atmospheric-Cherenkov telescopes. Significant detections are reported elsewhere for many of these objects. Here, integral flux upper limits for twelve candidate very high energy (VHE; >100 GeV) gamma-ray emitters are presented. In addition, results from HESS observations of four known VHE-bright AGN are given although no significant signal is measured. For three of these AGN (1ES 1101-232, 1ES 1218+304, and Mkn 501) simultaneous data were taken with the Suzaku X-ray satellite.

2007-01-01

447

Study of some Ayurvedic Indian medicinal plants for the essential trace elemental contents by instrumental neutron activation analysis and atomic absorption spectroscopy techniques  

Energy Technology Data Exchange (ETDEWEB)

Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)

2009-07-01

448

Role of additives in wood plastic composite of water soluble monomer  

International Nuclear Information System (INIS)

Wood plastic composites are prepared under radiation of "6"0Co gamma source with simul, a low grade wood of Bangladesh using a water soluble monomer acrylamide (AM) mixed with a swelling solvent methanol, water or methanol/water (1:1) at different compositions in the presence of a number of additives and co-additives such as NVP (N-vinylpyrrolidone), TPGDA (tripropylene glycol diacrylate), TMPTA (trimethylol propane triacrylate), sulfuric acid, urea and copper sulfate. Polymer loading (PL) and tensile strength (TS) of the composites are measured. The role of these additives on the composites is also discussed. It is observed that nitrogen-atom containing-materials like urea, NVP and AM produce composites with the highest mechanical strength, and incorporation of copper into this system provides additional property of protection and preservation of the composites against attacks by insects and microbes. (author).

1994-01-01

449

Photon-induced L-shell x-ray intensity ratio for elements with 73 #<=# Z #<=#83 in the energy range 17 #<=# E #<=# 47 keV  

International Nuclear Information System (INIS)

The L-shell x-ray intensity ratios I(L_#beta#)/I(L_#alpha#) and I(L_#gamma#)/I(L_a_l_p_h_a) for elements with 73 #<=# Z #<=# 83 have been measured at photon incident energies of 17.8, 25.8 and 46.9 keV. The emitted x-rays were measured with a Si(Li) detector system. The results for Re, Pt and Tl are being reported for the first time. A comparison is made of the experimental results with the calculated values obtained by using the theoretical x-ray emission rates, subshell ionisation cross sections, subshell fluorescence yields and Coster-Kronig transition probabilities. The experimental results are in reasonable agreement with the theoretical values. (author).

1988-01-01

450

New thermal neutron imaging facility at the University of Texas reactor  

Energy Technology Data Exchange (ETDEWEB)

A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.

1999-09-01

451

Mechanical properties of Cu-Ni-Be system alloys  

International Nuclear Information System (INIS)

The effects of addition of 0.17wt%Zr, 0.1wt%Mg and 0.1wt%Co on the mechanical properties of a Cu-1.2wt%Ni-0.2wt%Be alloy have been investigated. Adding Zr, Co or Mg to the Cu-Ni-Be alloy brings about the improvement in strength and stress relaxation property. The Zr, Co or Mg addition decreases the inter-precipitate spacing of #gamma#'' precipitates, resulting in the increase in strength. The higher resistance to the stress relaxation of the Zr- or Co-added alloy is attributed to the lower density of mobile dislocations. The improvement of stress relaxation property by the Mg addition is explained by the viscous glide motion of dislocations dragging Mg atoms, in addition to the lower density of mobile dislocations.

2010-07-01

452

Magnetic properties of B and AB-spinels Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Ni, Mg) materials  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of diluted spinels Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) systems have been studied by mean field theory, probability law and high-temperature series expansions method in the range 0 {<=} x {<=} 1. The exchange interactions are calculated by the first and second theory, respectively. The magnetic phase diagrams of Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) are calculated by the high-temperature series expansions, combined with the Pade approximants method. The critical exponent associated with the magnetic susceptibility ({gamma}) is deduced.

2010-08-06

453

Irradiation of polyethylene in the presence of antioxidants  

International Nuclear Information System (INIS)

The radiation induced reactions in LDPE in the presence of phenolic type antioxidants have been studied. It was shown that various antioxidants can influence the polyethylene network formation and the radical yield in different ways. The dependence of network structure on absorbed doses was determined by gel analysis, hot-set test and extraction of antioxidants for samples irradiated with accelerated electrons. It was found that the antioxidants eluted from polyethylene in higher percentage influence polymer crosslinking to a smaller degree. The ESR studies of #gamma#-irradiated blends of polyethylene with antioxidant indicate the presence of alkyl and phenoxyl radicals. The role of antioxidant molecules on radiation induced reactions in polyethylene-antioxidant systems is considered. The correlation between the network structure and the type of additive in polyethylene is also discussed. (author).

454

IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4  

Science.gov (United States)

Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)

1961-01-01

455

Electronic properties of Nb_3Ge and Nb_3Al from self-consistent pseudopotentials. I. Band structure and density of states  

International Nuclear Information System (INIS)

The self-consistent-pseudopotential method is applied to the A-15 compounds Nb_3Ge and Nb_3Al. The Fermi energy is found to lie in a region of very flat bands having a bonding character along the Nb chains. Comparison with the band structures of the (nonexistent) A-15 materials Nb_3Nb and Nb_3/sup asterisk/ (chains only) suggest that the p states on the Ge and Al atoms are instrumental in determining the position of the Fermi level. There is little evidence for rigid-band behavior in the Nb_3Al/sub x/Ge/sub 1-x/ system. Studies of the effects of chain dimerization in Nb_3Ge suggest that states at R and M are more likely candidates to participate in structural transitions than states at GAMMA or X.

456

Determination of macro, micro nutrient and trace element concentrations in Indian medicinal and vegetable leaves using instrumental neutron activation analysis  

Energy Technology Data Exchange (ETDEWEB)

Leafy samples often used as medicine in the Indian Ayurvedic system and vegetables were analyzed for 20 elements (As, Ba, Br, Ca, Ce, Cr, Cs, Co, Eu, Fe, K, La, Na, Rb, Sb, Sc, Sm, Sr, Th, Zn) by employing Instrumental Neutron Activation Analysis (INAA). The samples were irradiated at the 100 kW TRIGA-MAINZ nuclear reactor and the induced activities were counted by gamma ray spectrometry using an efficiency calibrated high resolution High Purity Germanium (HPGe) detector. The concentration of the elements in the medicinal and vegetable leaves and their biological effects on human beings are discussed.

1999-05-01

457

Availability of essential trace elements in Ayurvedic Indian medicinal herbs using instrumental neutron activation analysis  

Energy Technology Data Exchange (ETDEWEB)

Specific parts of several plants (fruits, leaves, stem, bark and roots) often used as medicines in the Indian Ayurvedic system have been analysed for 20 elements (As, Ba, Br, Ca, Cl, Co, Cr, Cu, Fe, K, Mn, Mo, Na, P, Rb, Sb, Sc, Se, Sr and Zn) by employing instrumental neutron activation analysis (INAA). The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted using high resolution gamma ray spectrometry. Most of the medicinal herbs have been found to be rich in one or more of the elements under study. (Author).

1997-01-01

458

A PAC containing the human mitochondrial DNA polymerase gamma gene (POLG) maps to chromosome 15q25  

Energy Technology Data Exchange (ETDEWEB)

The human mitochondrial DNA (mtDNA) is a closed circular, 16,569-bp double-stranded DNA, encoding 13 genes whose protein products are subunits of the oxidative phosphorylation system required for synthesis of most of the ATP consumed by eukaryotic cells. Point mutations of the mtDNA that cause multi-tissue, loss-of-energy syndromes, called mitochondrial encephalomyopathies (e.g., MERRF and MELAS), have been identified. In addition, large-scale deletions of the human mtDNA have been identified and are the molecular bases for the neonatal and adolescent onset loss-of-energy syndromes Pearson and Kearns-Sayer, respectively. 5 refs., 1 fig.

1997-03-01

459

A Hypothesis: Supplementation with Mushroom-Derived Active Compound Modulates Immunity and Increases Survival in Response to Influenza Virus (H1N1) Infection.  

Science.gov (United States)

We hypothesize that the mushroom-derived active compound may be a potential strategy for increasing survival in response to influenza virus (H1N1) infection through the stimulation of host innate immune response. The validity of the hypothesis can be tested by immune response to influenza infection as seen through survival percentage, virus clearance, weight loss, natural killer cell cytotoxicity, Tumor Necrosis Factor-? (TNF-?) and Interferon-gamma (IFN-?) levels, lytic efficiency in the spleens of mice and inducible nitric oxide synthase mRNA expressions in RAW 264.7 murine macrophage cells. The hypothesis may improve people's quality of life, reduce the medical cost of our healthcare system and eliminate people's fears of influenza outbreak. PMID:21660092

2011-03-20

460

Quantification of "2"3"5U and "2"3"8U activity concentrations for undeclared nuclear materials by a digital gamma-gamma coincidence spectroscopy  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium enrichment ...

2011-06-01

461

Gamma heating in LMFBR media  

International Nuclear Information System (INIS)

State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method was developed to permit rapid, accurate ...

1976-01-01

462

Flow Vaporization of CO{sub 2} in Microchannel Tubes  

Energy Technology Data Exchange (ETDEWEB)

Carbon dioxide is receiving renewed interest as an efficient and environmentally safe refrigerant in a number of applications, including mobile air conditioning and heat pump systems, and hot water heat pumps. Compact heat exchangers for CO{sub 2} systems are designed with small-diameter tubing. The purpose of this study is therefore to provide a better basis for understanding and predicting heat transfer and pressure drop during flow vaporization of CO{sub 2} in microchannels. The ''unusual'' properties of carbon dioxide give heat transfer and two-phase flow characteristics that are very different from those of conventional refrigerants. Examples of these differences are the much higher pressure, the resulting high vapour density, a very low surface tension, and a low liquid viscosity. High pressure and low surface tension has a major effect on nucleate boiling characteristics, and earlier test data have ...

2002-07-01

466

Production of MSSM Higgs bosons in #gamma##gamma# collisions  

International Nuclear Information System (INIS)

The heavy Higgs bosons H,A of the minimal supersymmetric extension of the Standard Model can be produced as resonances in high-energy #gamma##gamma# colliders. Prospects of the search for these particles in bb-bar and neutralino-pair final states are studied in this report. Heavy Higgs bosons can be found with masses up to about 70-80% of the initial e"+e"- collider energy for moderate values of tan #beta#, i.e. in areas of the parameter space not accessible at other colliders.

2001-10-11

467

Production of MSSM Higgs bosons at future #gamma##gamma# colliders  

International Nuclear Information System (INIS)

Future #gamma##gamma# colliders allow the production of the heavy neutral MSSM Higgs bosons H and A as single resonances. The prospects of finding these particles in the bb-bar and the neutralino-pair final states have been analyzed. The H, A bosons can be discovered for medium values of tan #beta# with masses up to 70-80% of the initial e"#+-#e"- c.m. energy. This production mode thus covers parts of the supersymmetric parameter space that are not accessible at other colliders.

2001-07-09

468

Probing Neutron Star Evolution with Gamma Rays  

Science.gov (United States)

The research sponsored by this grant was conducted in two fields of high-energy astrophysics:

1996-01-01

469

POTENTIATION BY PENTOBARBITAL OF THE PROTECTIVE ...  

Science.gov (United States)

... Accession Number : AD0268549. Title : POTENTIATION BY PENTOBARBITAL OF THE PROTECTIVE EFFECT OF AET AGAINST GAMMA RAYS. ...

1961-10-01

470

New physics effects on Higgs production at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study heavy physics effects on the Higgs production in #gamma##gamma# fusion using the effective Lagrangian approach. We find that the effects coming from new physics may enhance the standard model predictions for the number of events expected in the final states b-barb, WW, and ZZ up to one order of magnitude, whereas the corresponding number of events for the final state t-bart may be enhanced up to two orders of magnitude.

1996-02-20

472

Heavy charged Higgs boson production at next generation {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the scope of all relevant production modes of charged Higgs bosons in the MSSM, with mass larger than the one of the top quark, at future Linear Colliders operating in {gamma}{gamma} mode at the TeV energy scale. Final states with one or two H{sup {+-}} bosons are considered, as produced by both tree- and loop-level interactions. (orig.)

2003-07-01

473

Heavy charged Higgs boson production at next generation #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We investigate the scope of all relevant production modes of charged Higgs bosons in the MSSM, with mass larger than the one of the top quark, at future Linear Colliders operating in #gamma##gamma# mode at the TeV energy scale. Final states with one or two H"#+-# bosons are considered, as produced by both tree- and loop-level interactions. (orig.)

2003-07-01

476

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

477

Gamma ray detecting device using dislocation-free crystal  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.

1991-04-30

478

Free radicals in lysozyme reacted with peroxidizing methyl linoleate  

International Nuclear Information System (INIS)

... electron spin resonance gamma radiation lipids lyophilization lysozyme radicals

479

Four-fermion production at {gamma}{gamma} colliders: 1. Lowest-order predictions and anomalous couplings  

Energy Technology Data Exchange (ETDEWEB)

We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes {gamma}{gamma}{yields}4f and {gamma}{gamma}{yields}4f{gamma} in the standard model and extensions thereof by an effective {gamma}{gamma}H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes {gamma}{gamma}{yields}4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size ...

2004-08-01

480

Four-fermion production at #gamma##gamma# colliders: 1. Lowest-order predictions and anomalous couplings  

International Nuclear Information System (INIS)

We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes #gamma##gamma##->#4f and #gamma##gamma##->#4f#gamma# in the standard model and extensions thereof by an effective #gamma##gamma#H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes #gamma##gamma##->#4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size of ...

2004-08-01

482

Diquarks in gamma-p Collisions at LHeC  

CERN Document Server

This note studies the single production of scalar or vector diquarks at the LHeC collider.

2011-01-01

483

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

484

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

486

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

487

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

488

Carbide transformations in a gamma/gamma-prime nickel alloy during prolonged aging  

Energy Technology Data Exchange (ETDEWEB)

Carbide reactions occurring in a precipitation-hardening gamma/gamma-prime Ni-Cr alloy during prolonged high-temperature aging are investigated experimentally. It is found that the decomposition of primary MC carbides, which is accompanied by the precipitation of M23C6 particles, may lead to void nucleation and growth. The effect of carbide transformations on the residual properties of the material at temperatures above the equicohesion temperature is observed at the late stages of aging only. 6 references.

1988-08-01

491

A novel application of the multi-group method: Coupled neutron-gamma-electron cross-section library  

Energy Technology Data Exchange (ETDEWEB)

A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.

2006-02-15

492

A novel application of the multi-group method: Coupled neutron-gamma-electron cross-section library  

International Nuclear Information System (INIS)

A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.

2006-02-01

493

A Leptonic-Hadronic Model for the Afterglow of Gamma-Ray ...  

Science.gov (United States)

... PHYSICS ATOMIC AND MOLECULAR PHYSICS AND SPECTROSCOPY NUCLEAR PHYSICS & ELEMENTARY PARTICLE PHYSICS. ...

2010-11-20

494

Probing anomalous top-quark couplings induced by dim.6 operators at photon colliders  

Energy Technology Data Exchange (ETDEWEB)

Possible anomalous top-quark couplings induced by SU(2)xU(1) gauge-invariant dimension-6 effective operators were studied in the process of ttbar productions and decays at polarized {gamma}{gamma} colliders. Two CP-violating asymmetries, a linear-polarization asymmetry and a circular-polarization asymmetry, were computed including both non-standard ttbar{gamma} and {gamma}{gamma}H couplings. An optimal-observable analysis for the process {gamma}{gamma}{yields}ttbar{yields}l{sup {+-}} was performed in order to estimate the precision for determination of all relevant non-standard couplings, including the anomalous tbW coupling.

2004-06-21

495

Physical problems in proceses accompanying the laser conversion e#->##gamma#  

International Nuclear Information System (INIS)

Physical processes in the region of laser conversion for the next Linear Colliders (NLC) are discussed. The main goal of this conversion is to obtain high-energy intense #gamma# beams for #gamma#e and #gamma##gamma# colliders. This conversion has important by-products: (i) one can observe here effect of nonlinear QED (in a strong external field)-production of e"+e"- pairs by a high-energy photon and emission of very high-energy photons by an electron; (ii) one can produce and observe here the invisible axion in colliding #gamma#_0e beams. The NQED effects also result in variation of the spectra of high-energy photons and an additional background. 12 refs., 12 figs., 1 tab.

496

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01

497

GAMMA GLOBULIN METABOLISM IN RABBITS DURING THE ANAMNESTIC RESPONSE.  

Science.gov (United States)

1. Gamma globulin metabolism and distribution were studied employing rabbit gamma globulin (RGG)I(131) 24 times in 13 control rabbits. Similar studies were performed before and during the ananmestic response in 4 rabbits previously sensitized with a polyvalent pneumococcal vaccine. 2. During the ananmestic response, gamma-globulin levels increased from 1.0 to 6.0 gm/100 ml, and the gamma-globulin pool increased from 0.7 to 4.7 gm/kg. There was no change in the intravascular-extravascular partition of gamma globulin. 3. Gamma globulin degradation increased from 0.06 to 0.33 gm/kg/day during the 28 days of the immunization period while gamma globulin synthesis increased even further to average 0.47 gm/kg/day. Following the attainment of elevated gamma globulin levels the fractional rate of RGG-I(131) turnover increased ...

1964-04-01