A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
Possibility for using a sodium iodide scintillator as a reference signal source is considered. Experimental data on studying the performance of a gamma thickness gage with an additional scintillator are given. Results of experimental investigations of a thickness gage dummy proved practical expediency of the principle being considered. It is established, in particular, that the device is ready to operate without warm-up with a constant sensitivity, the deviation not exceeding 0.5%, in the ambient temperature range of 15-25 deg C.
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, ...
The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame ...
We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the ...
The measurement of thyroidal uptake of radioiodine using a gammacamera and computer is described. In 12 children there was good agreement with simultaneous measurements using a probe, while in a further 14 patients the uptake values were consistent with the clinical diagnosis. The technique should be especially useful for infants and small children.
Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by ...
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual ...
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
Based on BACODINE network notification the Whipple Observatory gamma-ray telescope has been used to search for the delayed TeV counterpart to BATSE-detected gamma-ray bursts. In the fast slew mode, any point in the sky can be reached within two minutes of the burst notification. The search strategy, necessary because of the uncertainty in burst position and limited FOV of the camera, is described.
A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between ...
The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium ...
Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of ...
Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability ...
The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport ...
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability ...
We discuss optimal detection of fast radio transients from astrophysical objects while taking into account the effects of propagation through intervening ionized media, including dispersion, scattering and scintillation.Our analysis applies to the giant-pulse phenomenon exhibited by some pulsars, for which we show examples, and to radio pulses from other astrophysical sources, such as prompt radio emission from gamma-ray burst sources and modulated signals from extra-terrestrial civilizations.
Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).
The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)
The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of LAAPDs in energy ...
A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gammacamera. Copyright (1999) Blackwell Science Pty Ltd
In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light ...
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: ...
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: ...
The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the ...
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma ...
In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five ...
The proposed portable device is suitable for radon surveys in water-bearing strata. It allows a complete transfer in activated charcoal canisters of radon dissolved in water collected with a 0.61 bottle. The detection is performed in laboratory with a low background {gamma}-ray spectrometer utilizing 3{sup x}3{sup N}aI({tau}I) scintillator only after about ten hours. This time is necessary to let radon be uniformly distributed within the activated charcoal.
Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...
The peak evaluation in alpha liquid scintillation is known to be easy, mostly due to the gaussian shape of the peaks. However, we often observed a high-energy tail in addition to a pure gaussian function. This effect is only detectable with a high resolution {alpha} liquid scintillation spectrometer such as the PERALS trademark system. Indeed, its intrinsic resolution (180 keV for a 4 MeV {alpha} particle) is better than that obtained for conventional LSC spectrometers. The peak asymmetry was quantified using the Fisher's coefficient {gamma}{sub 1} (symmetry factor). We show that the main effect responsible for the asymmetry is internal conversion. Indeed, most of the even-even nuclides have low {alpha} intensity transitions leading to excited levels of their daughter nuclides. The internal conversion is almost equal to 100% and consequently produces a sum peak at higher energy. No generalization is possible for ...
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal ...
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal ...
A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS method): A simple ...
Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup 198}Au reaction cross ...
In clinical applications, it is very important to accurately determine the range of a proton beam in a patient. Recently, a prototype prompt-gamma scanning system, called a prompt-gamma scanner (PGS), has been constructed at Hanyang University in Korea with the collaboration of the Korean national cancer center (NCC), based on a series of Monte Carlo simulations. The PGS system is composed of a prompt-gamma collimator, a CsI(Tl) scintillation detector, a multi-channel analyzer (MCA), a precision movement system, and an integrated readout system. The prompt-gamma collimator is designed to effectively shield high-energy neutrons from the proton beam passage and subsequent capture gammas. The PGS system can be used to scan the distribution of the prompt gammas in the patient from the proton beam passage. The distribution of the prompt ...
This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ...
The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the ...
Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee ...
The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). ...
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its ...
We present a set of structural parameters for the central parts of 57 early-type galaxies observed with the Planetary Camera of the Hubble Space Telescope. These parameters are based on a new empirical law that successfully characterizes the centers of early type galaxies. This empirical law assumes that the surface brightness profile is a combination of two power laws with different slopes gamma and beta for the inner and outer regions. Conventional structural parameters such as core radius and central surface brightness are replaced by break radius r_b, where the transition between power-law slopes takes place, and surface brightness mu_b at that radius. An additional parameter alpha describes the sharpness of the break. The structural parameters are derived using a chi-squared minimization process applied to the mean surface brightness profiles. The resulting model profiles generally give very good agreement to the observed profiles out to ...
A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average value is 0:70 +- ...
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
Polymeric coated ferromagnetic carriers with an absorbed layer of octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide (CMPO) diluted by tributyl phosphate (TBP) are being evaluated for application in the separation and the recovery of low concentrations of americium, plutonium, and uranium from nuclear waste solutions. Due to their chemical nature, these extractants selectively complex americium and plutonium contaminants onto the particles and the complexed particles can be recovered from the solution using a magnet. Physical and chemical characterization of the extractant-absorbed particles were performed by gamma and liquid scintillation counting, scanning electron microscopic (SEM) micrograph, and other physical measurements. Plutonium, americium, and uranium separations have been performed at various HNO{sub 3} and HCl concentrations. Parameters were studied to determine the limitations and capacity of the process. The status of the ...
There is an urgent need to improve the reliability of screening cargo containers for illicit nuclear material that may be hidden there for terrorist purposes. A screening system is described for detection of fissionable material hidden in maritime cargo containers. The system makes use of a low intensity neutron beam for producing fission; and the detection of the abundant high-energy #gamma# rays emitted in the #beta#-decay of short-lived fission products and #beta#-delayed neutrons. The abundance of the delayed #gamma# rays is almost an order of magnitude larger than that of the delayed neutrons normally used to detect fission and they are emitted on about the same time scale as the delayed neutrons, i.e., #approx#1 min. The energy and temporal distributions of the delayed #gamma# rays provide a unique signature of fission. Because of their high energy, these delayed #gamma# rays penetrate loW--Z ...
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gammacamera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material.
Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gammacamera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in a larger clinical material
The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillationcamera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the ...
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hip areas were made with a scintillationcamera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the ...
In this study the distribution of sup(99m)Tc-diphosphonate and tetracycline and histological examination were also investigated in femoral heads obtained during replacement surgery. One hundred patients received scintigraphic examinations immediately after the occurrence of injury and every month thereafter. Ten mCi of sup(99m)Tc-diphosphonate was injected intravenously. Three hours later, detailed scintigrams of the bilateral hips areas were made with a scintillationcamera connected to a computer. The uptake of sup(99m)Tc-diphosphonate in the fracture was expressed as a ratio of the counts recorded in one area to those recorded in the other area. A peak value in count ratio was recorded in all patients 4 to 6 weeks after fractures. One hundred patients were classified into a normal healing group and a delayed or non-union group. Namely, sup(99m)Tc-diphosphonate uptake was significantly higher in the delayed or non-union group than in the ...
{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gammacamera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space ...
Insulitis is considered the histopathological hallmark of type I diabetes. In the non-obese diabetic (NOD) mouse, diabetes has never been observed in the absence of insulitis. The in vivo detection of insulitis could be of relevance for early prediction of diabetes. As approximately 15% of islet-infiltrating lymphocytes express interleukin 2 receptors, the authors have labelled recombinant inter-leukin 2 with "1"2"3I and used this radiopharmaceutical to detect insulitis by gammacamera imaging. The authors studied 71 prediabetic NOD and 27 normal Balb/c mice. Labelled #alpha#-lactalbumin was used as the control protein. In the first set of experiments the tissue distribution of radiolabelled interleukin 2 in isolated organs from animals sacrificed at different time points was studied. Higher radioactivity was detected in the pancreas of NOD mice injected with labelled interleukin 2, as compared to NOD mice receiving labelled ...
We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.
ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons and gamma rays are resolved in both time ...
This project was supported through ERDA to demonstrate that the temporal distribution of tritium can be documented by the analysis of bound hydrogen in annual tree-ring samples. The project focuses on two sample locations at the Savannah River Site (SRS), a nuclear material production facility located in Aiken, SC. The SRS provided samples of cross-sections from a single tree that were to be pooled together for analysis. Annual tree-rings were identified in each cross-section sample and separated for the period 1954 to 1993. These annual samples were ground and chemically treated to separate the hollocellulose fraction of the wood, then subsequently combusted and the resulting water counting using low-level liquid scintillation counting equipment. Additionally, the ground annual tree-rings were gamma-counted to determine any temporal variation in radionuclide activity and analyzed with x-ray fluorescence to find any temporal variation in ...
We monitored PSR B0329+54 for one year using the Nanshan 25-m radio telescope, the scintillation velocity V ISS shows evidence of systematic variation with the day of the year. States of interstellar medium (ISM) are discussed.
The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify ...
The ability of the Packard 2000 CA/LL liquid scintillation counter to reduce background count rates relies on pulse shape/duration analysis in which short duration organic scintillation events are discriminated from longer duration non-quenchable background events. A consequence of this is a loss in the counting efficiency. The results of this investigation indicate that much of the lost efficiency can be regained by sharpening the true #beta#"- pulse widths via the use of different scintillant combinations and by certain counter modifications. (author).
Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the ...
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the ...
Q/sub ..beta..-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 less than or equal toA less than or equal to106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q/sub ..beta..-values between 2 and 8 MeV show errors of about 1.5% (with the exception of /sup 103/Zr and /sup 105/Nb resp. and /sup 103/Tc for which larger errors result due to statistical resp. systematic reasons): /sup 101/Zr 5500+-70, /sup 101/Nb 4580+-45, /sup 102/Zr 4670+-40, /sup 102/Nb 7230+-70, /sup 103/Zr 6790+-240, /sup 103/ 5740+-70, /sup 103/Mo 3575+-80, /sup 103/Tc 2585+-70, /sup 104/Nb 8250+-130, /sup 104/Mo 2180+-40, /sup 104/Tc 5520+-100, /sup 105/Nb 6570+-150, /sup 105/Mo 4885+-80, /sup 105/Tc 3750+-60, /sup 106/Mo 3515+-45, /sup 106/Tc 6540+-70, /sup 109/Ru 4150+-80, /sup 109/Rh 2550+-50 (all values in keV). For the measurement of ...
Q_#beta#-values are determined for 18 nuclei (Zr-, Nb-, Mo-, Tc-, Ru- and Rh-nuclides) with mass numbers 101 #<=# A #<=# 106 and A=109 from measurements of beta decay energies which were carried out at the LOHENGRIN mass separator at the Institut Laue-Langevin in Grenoble (France). The given Q_#beta#-values between 2 and 8 MeV show errors of about 1.5% (with the exception of "1"0"3Zr and "1"0"5Nb resp. and "1"0"3Tc for which larger errors result due to statistical resp. systematic reasons): "1"0"1Zr 5500#+-#70, "1"0"1Nb 4580#+-#45, "1"0"2Zr 4670#+-#40, "1"0"2Nb 7230#+-#70, "1"0"3Zr 6790#+-#240, "1"0"3 5740#+-#70, "1"0"3Mo 3575#+-#80, "1"0"3Tc 2585#+-#70, "1"0"4Nb 8250#+-#130, "1"0"4Mo 2180#+-#40, "1"0"4Tc 5520#+-#100, "1"0"5Nb 6570#+-#150, "1"0"5Mo 4885#+-#80, "1"0"5Tc 3750#+-#60, "1"0"6Mo 3515#+-#45, "1"0"6Tc 6540#+-#70, "1"0"9Ru 4150#+-#80, "1"0"9Rh 2550#+-#50 (all values in keV). For the measurement of beta-gamma coincidences a #DELTA#E/E-plastic ...
To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gammacamera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative ...
Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gammacamera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of [sup 99m]Tc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain ...
Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gammacamera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of "9"9"mTc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain on ...
Quantitative bone scans were evaluated in 16 patients with osteoporosis and in a control group of 7 healthy subjects. Along with a detailed biochemical analysis of calcium-phosphorus metabolism and standartized reongenographs, a quantitative dynamic bone scintigraphy was performed according to the method proposed by the authors. The bone-accumulating factor K_b was determined on the base of mathematical analysis of the graph reflecting activity changes in bone tissue unit during the investigation, the blood-elimination factor K_h and kidney-elimination factor K_k. In addition the accumulation index AI (in %) was calculated as a relation between the activity in bone tissue unit, registered in 20 min interval, and the activity in soft tissues for the same time. Whereas the static gammacamera scintigraphy, made 3-4 hrs after injecting of the osteotrope radiopharmaceuticals, showed no specific changes in the patients examined, the method proposed ...
Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of [sup 99m]Tc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gammacamera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal ...
Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of "9"9"mTc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gammacamera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal metastases. (orig.).
Quantitative assessment of bone scintigraphy was performed in fifty-six patients with hip joint disease including femoral neck fracture, aseptic necrosis of the femoral head, traumatic dislocation of the hip, Perthes disease, and transient synovitis of the hip. In the static study, bone scintigraphy was obtained 3 hours after injection of sup(99m)Tc-MDP by gammacamera equipped with a computer and uptake ratios were calculated. In the dynamic study, bone scintigraphy was performed in one, 3 and 5 hours after injection of radionuclide. Femoral head uptake ratio was markedly decreased in osteonecrosis following femoral neck fracture and characteristically increased in aseptic necrosis of the femoral head but prolonged retention of sup(99m)Tc-MDP could be observed. Uptake ratios of epiphysis were decreased in Perthes disease but normal in transient synovitis of the hip. Static and dynamic study of bone scintigraphy may be useful for early ...
The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled beta 2-microglobulin is taken up by the ...
Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gammacamera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. ...
A study of the influence of the concentration of secondary addition, high concentrations of primary dopant, diffusion enhancer and stabilizer on radiation hardness is presented. It is concluded that the diffusion enhancing technique is the most powerful method for improving radiation hardness. A new polystyrene scintillator which contains 2% pT, 0.02% POPOP, 20% diffusion enhancer and 0.02% stabilizer gave 91% of initial light output immediately after 3 Mrad irradiation in air. Data are presented that show that scintillator prepared from commercial polymer is more radiation-hard and has greater light output than scintillator prepared from monomer. It is assumed that this difference is due to different molecular weight distributions. Some protocols for acceleration of aging (yellowing and crazing) are presented. It is shown that one of the main reasons for aging of plastic scintillators is residual ...
Experimental excitation functions for deuteron-induced reactions up to 20 MeV on high purity natural hafnium were measured with the activation method using a stacked foil irradiation technique. Metallic hafnium foils with thickness of 10 #mu#m were stacked together with 50 #mu#m thick aluminium and 12 #mu#m thick titanium foils. The aluminium foils served as energy absorber while the titanium foils were used to monitor the energy and intensity of the bombarding deuteron beam. From a detailed remeasurement of the complete excitation function of the "n"a"tTi(d,x)"4"8V monitor reaction it was possible to adopt the proper incident energy and beam intensity by comparing the results with the recommended values. High resolution off-line gamma-ray spectrometry was applied to assess the activity of each foil. From the measured activity independent and/or cumulative elemental or isotopic cross section data for production of Ta, Hf and Lu radioisotopes by (d,x) reactions were ...
... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...
The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing corrections, respectively. Here, we introduce a ...
Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...
Low resolution and un-sharp facial images are always captured from surveillance videos because of long human-camera distance and human movements. Previous works addressed this problem by using an active camera to capture close-up facial images without considering human movements and mechanical delays of the active camera. In this paper, we proposed a unified framework to capture facial images in video surveillance systems by using one static and active camera in a cooperative manner. Human faces are first located by a skin-color based real-time face detection algorithm. A stereo camera model is also employed to approximate human face location and his/her velocity with respect to the active camera. Given the mechanical delays of the active camera, the position of a target face with a given delay can be estimated using a ...
Scintillation light in liquid xenon excited by 100 MeV/n Al ions was detected with a home-made silicon photodiode. The diameter of the photodiode was 2 inch. The effective quantum efficiency was observed to be 22% for the wavelength of liquid xenon scintillation light (170 nm), while the effective quantum efficiency for 5.486 MeV alpha-particle excitation was 44%. An energy resolution of 0.5% rms was achieved for the energy deposition of 2.5 GeV in liquid xenon using a fast preamplifier ({approx equal} 20 ns). (orig.).
The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.
The DNA Wideband satellite experiment provided extensive data on scintillation produced in high-altitude structured plasmas. A computer program, WBMOD, is being developed to summarize those data in an applications-oriented way. The program contains the phase-screen scattering theory of Rino and a morphological description of ionospheric irregularities (thus far only at auroral latitudes) based on Wideband observations. It permits a user to compute scintillation indices for both phase and intensity as a function of system operating parameters and solar-ionospheric disturbance level. Correction is made for multiple scatter, and the user may choose either one-way (communication) or two-way (radar) propagation.
The possibility to transform the future linear e"+e"-colliders into the #gamma#e and #gamma##gamma# colliders with approximately the same energies and luminosities was shown earlier. Their properties are compared from the point of view of possible physical investigations on them. 10 refs.; 1 tab.
... Zinn, J., Hoerlin, H., and Petschek, AG, "The Motion of Bomb Debris Follow- ing the Starfish Test," Radiation Trapped in the Earth's Magnetic Field ...
The WAND (Waste Assay for Nonradioactive Disposal) system can scan thought-to-be-clean, low-density waste (mostly paper and plastics) to determine whether the levels of any contaminant radioactivity are low enough to justify their disposal in normal public landfills or similar facilities. Such a screening would allow probably at least half of the large volume of low-density waste now buried at high cost in LANL`s Rad Waste Landfill (Area G at Technical Area 54) to be disposed of elsewhere at a much lower cost. The WAND System consists of a well-shielded bank of six 5-in.-diam. phoswich scintillation detectors; a mechanical conveyor system that carries a 12-in.-wide layer of either shredded material or packets of paper sheets beneath the bank of detectors; the electronics needed to process the outputs of the detectors; and a small computer to control the whole system and to perform the data analysis. WAND system minimum detectable activities (MDAs) for point sources ...
Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin liquid scintillator with good time resolution capabilities. Neutron energies were determined by time-of-flight techniques with pulse-shape ...
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional counters, 2) Boron-lined proportional counters, 3) Lithium-loaded glass ...
A gel-type "9"9Mo-"9"9"mTc generator using Titanium-Molybdate target (TiMo-target) as column packing was developed in Radioisotope Department, the Dalat Nuclear Research Institute [1]. The concentration of trace elements in TiMo-target and radionuclidic purity in "9"9"mTc solution eluted from this type of generator were studied for quality control purpose. The monostandard method in neutron activation analysis has been applied to determine the concentration of trace impurities in titanium-molybdate target. For neutron activation analysis, TiMo samples were irradiated in the different channels of nuclear reactor IVV-9 at a neutron flux of maximum 2.1 x 10"1"3 n.cm"-"2s"-"1. The following chemical element impurities were determined: Na, W, Co, Fe, Zn, Ag, Sb and Cr. The gamma ray emitted nuclides found in "9"9"mTc solution eluted from our "9"9"mTc generator were the following: "6"5Zn, "6"0Co, "1"1"0"mAg, "5"9Fe, "5"1Cr, "2"4Na, "8"2Br and "9"9Mo. "9"9Mo was found ...
Carbon-14 was analysed by direct absorption of carbon dioxide on the mixture of organic amine compound and scintillation cocktail then counted by low level liquid scintillation counter. This method can be applied for radiocarbon dating. In this study, the effects of carbon dioxide absorption, and counting efficiency were investigated using various commercial available cocktail. It was found that permafluor V and Ready Gel showed the highest carbon dioxide absorption whereas the Permafluor V showed the highest counting efficiency
A microemulsion comprised of water, Brij 78, pentanol and styrene into which PPO and bis-MSB had been dissolved was prepared. Polymerization of the styrene resulted in a suspension of fluor-containing polystyrene nanoparticles (<100 nm). After a concentration step, the aqueous nanosuspension was able to detect {sup 14}C with counting efficiencies over 50% of those of a commercially available scintillation cocktail. Monte Carlo calculations demonstrated that the size and concentration of the nanoparticles were appropriate for optimum detection efficiency.
Radiowave scintillation in the presence of ionospheric disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report describes development of a model characterizing the plasma density irregularities that produce scintillation in the naturally disturbed mid-latitude F layer. The model will be incorporated into Program WBMOD, which includes subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. Earlier versions of WBMOD, were based on extensive analysis of scintillation data collected in the auroral and equatorial zones in Wideband Satellite Mission. The model described herein is based on similarly extensive analysis of Wideband data from one mid latitude station and of data collected from HiLat satellite at another mid latitude station. The model describes irregularities at an effective ...
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation detector and to ...
Lithium carbonate pellets are frequently used for estimation of tritium production rate in irradiated samples in fusion blanket neutronics experiment and the activity is measured by liquid scintillation counting technique. In this measurement, it is essential to solve the lithium carbonate pellet as much as possible and to mix the pellet solution into scintillation cocktail homogeneously at stable condition. For this purpose, a novel binary-acid method has been developed to solve lithium carbonate and to mix the pellet solution into scintillation cocktail. High solubility is attained by adopting two acids, HNO_3 and CH_3COOH, and a good compatibility of the pellet solution with scintillator is obtained by emulsion cocktail resulting in high counting efficiency. Defining a product of dissolved mass and counting efficiency as a Figure of Merit (FOM), the present method has higher FOM value than the ...
Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...
(telescopes, cameras, mirrors, solar cookers); Explain to students that the Genesis spacecraft has a concentrator that collects special types of atoms from ...
was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...
In the autonomous unmanned helicopter landing problem, the position of the unmanned helicopter relative to the landmark is very important. A camera carried on the unmanned helicopter can capture an image of the landmark. In earlier research, it was reported that the camera position could be estimated by features extracted from the landmark image. However, it is necessary that the landmark image should be complete, or with only slight deficiencies, in order for this estimation process to be possible. In this article, we report on an innovative design for an estimation made from a camera position giving an incomplete single image of the landmark. An adaptive neuro-fuzzy inference system (ANFIS) is used to construct the mapping relation between the features of complete and incomplete landmark...
Post-drive imaging included 360-degree view by the navigation camera and .... Sol 938: Opportunity completed another assessment of the clarity of the sky. ...
The symmetrical complexes [{sup 99m}Tc][TcN(R{sub 2}PS{sub 2}){sub 2}] [R = CH{sub 3}, CH{sub 2}CH{sub 3}, CH{sub 2}CH{sub 2}CH{sub 3}, CH{sub 2}(CH{sub 3}){sub 2}], and the unsymmetrical complex [{sup 99m}Tc][TcN(Me{sub 2}PS{sub 2})(Et{sub 2}PS{sub 2})] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R{sub 2}PS{sub 2}]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding {sup 99}Tc-analogs prepared, at macroscopic level, by reacting the complex [{sup 99}TcNCl{sub 4}] [n-Bu{sub 4}N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two ...
The symmetrical complexes ["9"9"mTc][TcN(R_2PS_2)_2] [R = CH_3, CH_2CH_3, CH_2CH_2CH_3, CH_2(CH_3)_2], and the unsymmetrical complex ["9"9"mTc][TcN(Me_2PS_2)(Et_2PS_2)] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R_2PS_2]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding "9"9Tc-analogs prepared, at macroscopic level, by reacting the complex ["9"9TcNCl_4] [n-Bu_4N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two dithiophosphinate ligands spanning the four positions on the basal plane through the four sulfur atoms of the >PS_2 group. ...
Quantitative bone scintigraphy was performed in patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months after operation. The count rate was recorded as serial gammacamera images over the lower thoracic and all lumbar vertebrae from 1 to 240 min and at 24 h after injection of "9"9"Tc"m-MDP. In almost all abnormal vertebrae an increased count rate was observed within one hour after injection. Most of the vertebrae which were considered normal at 4 h after injection, but had an increased 24h/4h ratio developed into abnormal vertebrae later in the study. The patients with normal bone scintigrams showed no change in "9"9Tc"m-MDP uptake during the study. The reproducibility of quantitative bone scintigraphy was found to be #+-# 7% (1 SD). In response to therapy, most of the patients with abnormal bone scintigrams showed an increase in count rate two weeks after operation followed by a decrease to the ...
Microcapsules consisting of alginate and hyaluronic acid that can be decomposed by radiation are currently under development. In this study, the composition of the microcapsule material was optimized by changing the amounts of alginate and hyaluronic acid. Solutions of 0.025%, 0.05%, 0.1%, 0.2%, or 0.4% (wt./vol.) hyaluronic acid were mixed into a 0.2% alginate solution. To these mixtures, carboplatin (0.2 mmol) was added and the resulting material was used for the capsule preparation. The capsules were prepared by spraying the material into a CaCl{sub 2} solution (0.34 mol/l) using a microatomizer. These capsules were irradiated by a single dose of 2, 5, or 10 Gy {sup 60}Co {gamma}-ray radiation. Immediately after irradiation, the releasing of core content of microcapsule was determined, using a micro particle induced X-ray emission (PIXE) camera. The average diameter of the microcapsules was 22.3 {+-} 3.3 {mu}m, and that of the liquid core ...
Quantitative I-131 labelled Peanut lectin (I-131-PNA) renal clearance was determined in dogs before and after a 5 day single cycle cis-platinum chemotherapy regimen (0.5mg/Kg/day). Results were statistically compared with E.R.P.F. (I-131-Hippuran), G.F.R. (Tc-99m-DTPA), and serum biochemistry and correlated with histopathology. I-131-PNA clearance was significantly reduced in all dogs 5 days after cessation of cis-platinum treatment (mean #DELTA#S% = 71.3%) and similar reductions in the gammacamera derived renogram peak were demonstrated (mean #DELTA#S% = 65.8%). E.R.P.F. was noted to drop by a minor degree (mean #DELTA#S% = 20.9%) post treatment. G.F.R. was diminished (mean #DELTA#S% = 46.6%) and serum creatinine elevated (mean #DELTA#S% = 42.7%) in all dogs compared to their pretreatment values. Histopathology demonstrated variable degrees of tubular toxicity ranging from mild to severe. The degree of change of the I-131-PNA values was ...
Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with {sup 131}I-labeled intact CEA 102 or its F(ab'){sub 2}. Primary tumor and liver metastases were successfully detected by external scanning with a gammacamera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of {sup 131}I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted ...
Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with "1"3"1I-labeled intact CEA 102 or its F(ab')_2. Primary tumor and liver metastases were successfully detected by external scanning with a gammacamera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of "1"3"1I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in ...
Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gammacamera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with the cerebellum used ...
Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This leads to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate "1"6"6Ho-Hydroxyapatite ("1"6"6 Ho-HA) as potential radiopharmaceutical for the symptomatic treatment of chronic and acute arthritis. Materials and Methods: Holmiun-166 was produced by irradiation of Ho_2O_3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthesized. Its labelling and quality controls follows the internationally accepted procedures. An antigen's arthritis was induced to eight New Zealand rabbits with the "1"6"6 Ho-HA radiochemical being administered thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon clinical improvement and ...
It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).
We discuss the search of excited leptons and quarks with spin 1/2 at #gamma##gamma# and at #gamma#e colliders. We show that #gamma##gamma# colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l"*l#gamma# transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).
For several decades most of the efforts to develop new scintillator materials have concentrated on high-light-yield inorganic single-crystals while polycrystalline ceramic scintillators, since their inception in the early 1980 s, have received relatively little attention. Nevertheless, transparent ceramics offer a promising approach to the fabrication of relatively inexpensive scintillators via a simple mechanical compaction and annealing process that eliminates single-crystal growth. Until recently, commonly accepted concepts restricted the polycrystalline ceramic approach to materials exhibiting a cubic crystal structure. Here, we report our results on the development of two novel ceramic scintillators based on the non-cubic crystalline materials: Lu SiO:Ce (LSO:Ce) and LaBr:Ce. While no evidence for texturing has been found in their ceramic microstructures, our LSO:Ce ceramics exhibit a surprisingly ...
An analysis was perfonned on the mid-latitude scintillation and coherence frequency bandwidth (Fcoh) using transionospheric VHF signal data. The data include 1062 events spanning from November 1997 to June 2002. Each event records FORTE satellite received VHF signals from LAPP located at Los Alamos, New Mexico. Fcohs were derived to study scintillation characteristics on diurnal and seasonal variations, as well as changes due to solar and geomagnetic activities. Comparisons to the VHFIUHF coherence frequency bandwidth studies previously reported at equatorial and mid-latitude regions are made using a 4th power frequency dependence relationship. Furthennore, a wideband ionospheric scintillation model, WBMOD, was used to estimate Fcohs and compared with our VHF Fcoh values. Our analysis indicates mid-latitude scintillation characteristics that are not previously revealed. At the VHF bottom frequency range ...
The authors study the processes {gamma}e {r{underscore}arrow} {gamma}e and {gamma}{gamma} {r{underscore}arrow} {gamma}{gamma}, in the context of the proposal for Weak Scale Quantum Gravity (WSQG) with large extra dimensions. With an ultraviolet cutoff M{sub S} {approximately} 1 TeV for the effective gravity theory, the cross sections obtained for these processes at the Next Linear Collider (NLC), with the e{gamma} an {gamma}{gamma} options, deviate from the predictions of the Standard Model significantly. The results suggest that, for typical proposed NLC energies and luminosities, the predictions of WSQG can be tested in the range 1 TeV {approx{underscore}lt} M{sub S} {approx{underscore}lt} 10 TeV, making e{gamma} an {gamma}{gamma} colliders important tools for probing WSQG.
We summarize the predictions of different models for total #gamma##gamma# cross-sections. The experimentally observed rise of #sigma#_#gamma#_#gamma# with s radical _#gamma#_#gamma#, faster than that for #sigma#_p_-_b_a_r_p, #sigma#_#gamma#_p is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of #sigma#_#gamma#_#gamma# with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range 300< s radical_#gamma#_#gamma# <500 GeV. We further show that the difference in model predictions for ...
Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alpha source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from ...
Methods for improving the sensitivity of scintillation cells for radon concentration measurements were studied with emphasis on improving light collection efficiency. This allows the length and hence the volume of the cell to be increased. Variables studied were choice of scintillator material, its method of application and thickness, length of cell, cell material, type and configuration of reflectors, choice of photomultipliers, and factors affecting background. Response from various areas of the cell surface was studied with an alphy source and with radon filling. Coating the window with phosphor was found to be counter-productive. The optimum results obtained were with the inside of the cell (other than the window) covered with a thick layer of ZnS(Ag), or with a thick layer of reflective material coated with a thin layer of phosphor. With it, a 10 cm diameter plexiglass cell can be extended to at least 50 cm length without difficulty from ...
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained experimentally.
Three possibilities to observe the Higgs-top interaction at future {gamma}{gamma}-colliders are discussed: (a) associated Higss production via the {gamma}{gamma}{yields}tanti tH reaction, (b) Higgs obliged radiative correction to the {gamma}{gamma}{yields}tanti t channel, (c) Higgs resonance production via {gamma}{gamma}{yields}H{yields}ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at {gamma}{gamma}-colliders. (orig.).
Three possibilities to observe the Higgs-top interaction at future #gamma##gamma#-colliders are discussed: a) associated Higss production via the #gamma##gamma##->#tanti tH reaction, b) Higgs obliged radiative correction to the #gamma##gamma##->#tanti t channel, c) Higgs resonance production via #gamma##gamma##->#H#->#ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at #gamma##gamma#-colliders. (orig.).
The first meeting on e{gamma}/{gamma}{gamma} colliders was held on September 28 and 29, 1993, at the National Laboratory for High Energy Physics. After general remarks were delivered, lectures were given on QED in intense laser field, photon linear collider, laser focusing, luminosity distribution in the e{gamma}/{gamma}{gamma} colliders, QCD correction for {gamma}{gamma}{yields}H, radiation correction for e{gamma}/{nu}W process, SUSY particle production at the e{gamma} and {gamma} gamma colliders, formation of e{sup *} in e{gamma} collision, and general remarks on the theory. Discussion was carried out on `Where are we going from here?` In this book, the gists of the lectures are collected. (K.I.).
Methylation of RNA by methyltransferases is a phylogenetically ubiquitous post-transcriptional modification that occurs most extensively in transfer RNA (tRNA) and ribosomal RNA (rRNA). Biochemical...Full Text Available
The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).
(I)Results are given for photoproduction of the D{sup *} at 103 GeV. Clean signals are seen for the decay D{sup *{+-}} {yields} {pi}{sup {+-}}D{sup 0} with the D{sup 0} decaying into both K{sup {-+}}{pi}{sup {+-}} and K{sup {-+}}{pi}{sup {+-}}{pi}{sup 0}. Analysis of the Dalitz plot for the K{pi}{pi} mode gives branching fractions (BFs) for K{sup {minus}}{rho}{sup +}, K{sup *{minus}}{pi}{sup +}, and {anti K}{sup *0}{pi}{sup 0} final states. The BF for D{sup 0} {yields} K{sup {minus}}{rho}{sup +}, much lower than a previous result, is in approximate agreement with the value expected for an l=1/2 final state. (II)Inelastic and elastic J/{psi} photoproduction on H is investigated at 103 GeV. The inelastic cross section with E{sub {psi}}/E{sub {gamma}} {lt} 0.9 is significantly lower than the corresponding result for muoproduction on Fe targets, but consistent with second-order perturbative QCD calculation. The mean p{sub +} of inelastic events is larger than that of ...
Single crystals of GdCl_3 doped with different concentrations of Ce"3"+ have been grown using the Bridgman-Stockbarger technique and their luminescence and scintillation properties were investigated. The luminescence spectrum of GdCl_3:Ce"3"+ is complex and consists of two bands with maxima at 350 nm and 370 nm. The maximal light yield in GdCl_3:Ce"3"+ was observed at #approx#1 mol% of Ce"3"+ (more than 38 000 ph/MeV).
LUCIFER (Low-background Underground Cryogenic Installation For Elusive Rates) is a new project for the study of neutrinoless Double Beta Decay, based on the technology of scintillating bolometers. These devices promise a very efficient rejection of the alpha background, opening the way to a virtual background-free experiment if candidates with a transition energy higher than 2615 keV are investigated. The baseline candidate for LUCIFER is 82Se. This isotope will be embedded in ZnSe crystals grown with enriched selenium and operated as scintillating bolometers in a low-radioactivity underground dilution refrigerator. In this paper, the LUCIFER concept will be introduced. The sensitivity and the very promising prospects related to this project will be discussed.
A large scintillation chamber of 6.7 l volume for direct radon concentration measurements in gas is presented. With two 5 in. photomultipliers on opposite sides, working in coincidence, a concentration as low as about 0.5 mBq/l is detectable with 10% standard deviation after 1000 min measuring time. With the achieved background count rate of 0.42 counts/min and the counting efficiency of 0.607 for [sup 222]Rn and its progenies the absolute minimal detectable specific activity is reached with 0.17 mBq/l at about 12 000 min. The method to determine this minimum detectable activity is outlined. ((orig.))
The Gamma Physics (GaP) program of physical phenomena investigation is proposed on #gamma#p, #gamma#e and #gamma##gamma# colliders at TeV energies. The program contains specialized software (CompHEP system) created for automation of particle interaction processes calculations in the framework of various gauge models. Preliminary physical results are presented (heavy quark production, W, Z production, supersymmetry etc.), and further software development is suggested. (R.P.) 22 refs., 8 figs., 4 tabs.
The cross sections of neutral tensor mesons T=a_2, f, f', ... production in the exclusive #gamma##gamma##->#TT' or semiexclusive #gamma##gamma##->#TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV"2 are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future #gamma##gamma#-colliders is discussed too. (orig.).
Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).
We study the signals for composite vector leptoquarks in e"+e- colliders (CERN e"+e- collider LEP II, Next Linear Collider, and CERN Linear Collider) through their effects on the production of jet pairs, as well as their single and pair productions. We also analyze their production in #gamma#e and #gamma##gamma# collisions.
Fabry Perot interferometry is a method of determining instantaneous velocities of an object in motion. The interferometer system is composed of the Fabry Perot interferometer, a laser, an electronic streak camera, and several focusing lenses. The first tests discussed were done on exploding bridgewire devices. During these tests, several system parameters were changed. These changes did not seem to affect the data, which appeared to be consistent. The second tests performed focused on slapper-type devices. It was determined that sandblasted, vapor-deposited aluminum on the slapper material would be required to yield quality data. Streak camera failure prevented much data from being collected. An effort is being made to replace the current streak camera. After it is replaced, a Fabry Perot and velocity interferometry system for any reflector comparison will be made. The results will be published as the conclusion to this ...
The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.
The angular ..gammagamma..-correlations for nuclei of Sr even-even isotopes with A=82, 84, 86, 88 were measured. Multipole structurs of ..gamma..-transtion series and th coefficients multipole mixing were determined.
The angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes with a=8 82, 84, 86, 88 were measured. Multipole structurs of #gamma#-transtion series and th coefficients multipole mixing were determined.
The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)
There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.
Serotonin is one of the neurotransmitters found in the brain and mediates brain functions. It is very well known that serotonin related brain abnormalities are exerted mainly via serotonin receptors in a similar manner to other neurotransmitters found in the brain. Recently, it has also been found that serotonin is involved in Alzheimer's disease either directly or indirectly by its actions on serotonergic neurons. To understand and treat the diseases caused by abnormalities in the serotonergic system in the brain, it is certain that its mechanism of function has to be well investigated. So far several 5-HT receptors and receptor subtypes have been well characterized. Moreover, serotonin agonists and antagonists acting on specific receptors are chemically synthesized and are now available for the prevention or treatment of serotonergic related diseases. In recent years, a great demand for developing neuroimaging agents has emerged for the diagnosis of abnormal brain functions in the ...
We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)
We discuss the search of excited leptons and quarks with spin 1/2 at {gamma}{gamma} and at {gamma}e colliders. We show that {gamma}{gamma} colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l{sup *}l{gamma} transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).
Wildlife Monitoring System Schematic .......................... 40 ...... sentinel species - healthy fish are placed in an environment of water (where they arc not .... The way ir! which data for the fnre mdor study groups will be gathered tor managciacilt ...... Earth Resources Aircraft Program (ERAP) Camera ...
Reliable dietary assessment is a challenging yet essential task for determining general health. Existing efforts are manual, require considerable effort, and are prone to underestimation and misrepresentation...Full Text Available
The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.
What happens in the matrix of gender, technology, representation, and culture? This class will explore the theoretical issues raised within this matrix. We will also make sense of the theories through practical experiences with technologies like computers and cameras.
We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. ...
...COMCAM forces document Air Force and air component activities...supported unified command or joint task force commander, through the...Force COMCAM forces in a joint environment. If an...share of Unified Command headquarters COMCAM and visual...
We present here the preliminary design of ARIES-Devasthal Faint Object Spectrograph and Camera (ADFOSC), which is a multi-mode instrument for both imaging and spectroscopy. ADFOSC is the first-generation instrument to be mounted at the axial port of the Cassegrain focus on our new 3.6m optical telescope to be installed at Devasthal, Nainital. The main design goals of the instrument are : the instrument will have capability of broad- and narrow-band imaging, low-medium resolution spectroscopy, and imaging polarimetry. The operating wavelength range will be from 360 to 1000 nm and the instrument will have remote-control capability.
During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.
In this talk I briefly summarize different models for #sigma#_2_#gamma#"t"o"t (e"+e"-#->##gamma##gamma##->#hadrons) and contrast model predictions with the data. I will then discuss the capability of the future e"+e"- and #gamma##gamma# colliders to distinguish between various models and end with an outlook for future work.
Radiowave scintillation in the presence of natural and/or high-altitude nuclear disturbances has the potential to disrupt numerous transionospheric radio and radar systems. This report develops a model characterizing the plasma-density irregularities that produce scintillation in the naturally disturbed equatorial F layer. The model is incorporated into Program WBMOD along with subroutines for computing both link geometry and scintillation indices, the latter by means of phase screen diffraction theory. The model is based on similarly extensive analysis of wideband data from two equatorial stations. It describes irregularities at an effective height of 350 km that are isotropic across the geomagnetic field and elongated by a factor of 50 along the field and whose one-dimensional spatial power spectrum obeys a single-regime power law with a (negative) spectral index of 1.5. The height-integrated spectral strength of the ...
A #gamma##gamma# collider would extend and complement the physics capability of a linear collider; e.g. it would be suitable for direct measurement of the partial decay width of a Higgs boson into two gamma quanta. This paper discusses choice of laser parameters, luminosity optimization, electron and laser parameters for a gamma- gamma collider as a second interaction region for the Next Linear Collider, laser path, and the lasers. It is concluded that a gamma- gamma collider is technically feasible; however it will require a significant investment in preparatory R ampersand D.
We investigate the chargino production process {gamma}{gamma} {yields} (W-tilde){sup +}(W-tilde){sup -} at high energy {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy {gamma} beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background {gamma}{gamma} {yields} W{sup +}W{sup -}. (author).
We investigate the chargino production process #gamma##gamma# #-># (W-tilde)"+(W-tilde)"- at high energy #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy #gamma# beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background #gamma##gamma# #-># W"+W"-. (author).
By generalizing the algebra satisfied by the ..gamma../sub 5/ matrix, it is possible to give an extension of ..gamma../sub 5/ to d dimensions. We discuss the connection of this scheme to others.
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeV electron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of correction factors for five different kinds of electron energy. The preferable linear correlation of 0.997 of ...
Laser devices are currently in widespread use in particular by armed forces for different tasks. Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser damage depends on the interaction between the laser beam and the atmosphere in which it traverses. The atmospheric conditions, including the range, terrain features, turbulence, and atmospheric particulates, may alter the laser's effect on different electro-optical devices and systems. When a laser beam passes through the atmosphere the optical turbulence affects the beam. As a result, temporal intensity fluctuations (scintillations) or spatial variations in intensity within a beam cross-section occur. Atmospheric scintillations pose a safety problem because an observer or sensor can be subjected to the risk of a localized irradiance (local focusing effect) much greater than that ...
Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth's ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can be used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the second year, which include completion of the new models for the equatorial region and initial development of models for the high latitude (auroral and polar cap) region.
Many modern military systems used for communications, command and control, navigation, and surveillance depend on reliable and relatively noise-free transmission of radiowave signals through the earth`s ionosphere. Small-scale irregularities in the ionospheric density can cause severe distortion, known as radiowave scintillation, of both the amplitude and phase of these signals. The WBMOD computer program can he used to estimate these effects on a wide range of systems. The objective of this study is to investigate improvements to the WBMOD model based on extensive data sets covering both the equatorial and high-latitude regimes. This report summarizes the work completed during the third year of this project, which includes completion of the new model for the high-latitude (auroral and polar cap) region of the WBMOD model.
The collisions of high energy photons produced at an electron-positron collider provide a comprehensive laboratory for testing QCD, electroweak interactions, and extensions of the standard model. The luminosity and energy of the colliding photons produced by backscattering laser beams is expected to be comparable to that of the primary e"+e"- collisions. In this overview, we shall focus on tests of electroweak theory in photon-photon annihilation, particularly #gamma##gamma##->#W"+W"-, #gamma##gamma##->#Higgs bosons, and higher-order loop processes, such as #gamma##gamma##->##gamma##gamma#, Z#gamma# and ZZ. Since each photon can be resolved into a W"+W"- pair, high energy photon-photon collisions can also provide a remarkably background-free laboratory for studying WW collisions and annihilation. We also review high energy #gamma##gamma# tests of quantum chromodynamics, ...
The cross sections of neutral tensor mesons T=a{sub 2}, f, f', ... production in the exclusive {gamma}{gamma}{yields}TT' or semiexclusive {gamma}{gamma}{yields}TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV{sup 2} are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future {gamma}{gamma}-colliders is discussed too. (orig.).
We summarize the predictions of different models for total {gamma}{gamma} cross-sections. The experimentally observed rise of {sigma}{sub {gamma}}{sub {gamma}} with s radical {sub {gamma}}{sub {gamma}}, faster than that for {sigma}{sub p-barp}, {sigma}{sub {gamma}}{sub p} is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of {sigma}{sub {gamma}}{sub {gamma}} with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range ...
The results that can be expected by e#gamma# and #gamma##gamma# colliders in future are summarized. e#gamma# and #gamma##gamma# colliders have many fine possibilities, and are the economical selection for utilizing future e"+e"- colliders more effectively. e#gamma# and #gamma##gamma# colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e"+e"- collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e#gamma# and #gamma##gamma# colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e"+e"- accelerators. The production of #gamma#-beam is explained. As for the physics ...
We analyze spin correlations between top quark and anti-top quark produced at polarized e{sup +} e{sup -} and {gamma}{gamma} colliders. We consider a generic spin basis to find a strong spin correlation. Optimal spin decompositions for top quark pair are presented for e{sup +}e{sup -} and {gamma}{gamma} colliders. We show the cross- section in these bases and discuss the characteristics of results.
In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process {gamma}{gamma}{yields}HH are calculated. It is shown that the cross section is measurable at TeV {gamma}{gamma} colliders and is marginally sensitive to the triple-Higgs variation. (orig.).
In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process #gamma##gamma##->#HH are calculated. It is shown that the cross section is measurable at TeV #gamma##gamma# colliders and is marginally sensitive to the triple-Higgs variation. (orig.).
The complementarity of e{sup +}e{sup -} and {gamma}{gamma} colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios, we concentrate in detail on signatures for Large Extra Dimensions via the process {gamma}{gamma}{yields}WW.
The complementarity of e"+e"- and #gamma##gamma# colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios, we concentrate in detail on signatures for Large Extra Dimensions via the process #gamma##gamma##->#WW.
The complementarity of e{sup +}e{sub {minus}} and gamma-gamma colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios the authors concentrate in detail on signatures for Large Extra Dimensions via the process gamma-gamma --> WW.
Peroxisome proliferator activated receptor-{gamma} (PPAR{gamma}) regulates metabolic homeostasis and adipocyte differentiation, and it is activated by oxidized and nitrated fatty acids. Here we report the crystal structure of the PPAR{gamma} ligand binding domain bound to nitrated linoleic acid, a potent endogenous ligand of PPAR{gamma}. Structural and functional studies of receptor-ligand interactions reveal the molecular basis of PPAR{gamma} discrimination of various naturally occurring fatty acid derivatives.
The results that can be expected by e{gamma} and {gamma}{gamma} colliders in future are summarized. e{gamma} and {gamma}{gamma} colliders have many fine possibilities, and are the economical selection for utilizing future e{sup +}e{sup -} colliders more effectively. e{gamma} and {gamma}{gamma} colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e{sup +}e{sup -} collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e{gamma} and {gamma}{gamma} colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e{sup +}e{sup -} accelerators. The production of {gamma}-beam is ...
We investigate the sparticle production processes e{gamma} {yields} e tilde(Z tilde){sub 1} and {gamma}{gamma} {yields} (f tilde)(f tilde and bar) at high energy e{gamma} and {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e{gamma} colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e{gamma} {yields} (e tilde)(Z tilde){sub 1}. We show that the standard background processes e{gamma} {yields} {nu}W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e{gamma} {yields} (e ...
We investigate the sparticle production processes e#gamma# #-># e tilde(Z tilde)_1 and #gamma##gamma# #-># (f tilde)(f tilde and bar) at high energy e#gamma# and #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e#gamma# colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e#gamma# #-># (e tilde)(Z tilde)_1. We show that the standard background processes e#gamma# #-># #nu#W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e#gamma# #-># (e tilde)(Z tilde)_1 and ...
Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...
We analyze the potential of the e{sup +}e{sup -} linear colliders, operating in the e{gamma} and {gamma}{gamma} modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2){sub L}(circle times)U(1){sub Y} chiral operators of order p{sup 4} that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e{gamma} and {gamma}{gamma} modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10{sup -2} at 90% C.L. Moreover, the information gathered in the e{gamma} mode can be used to reduce the ambiguities of the e{sup +}e{sup -} mode.
We analyze the potential of the e"+e"- linear colliders, operating in the e#gamma# and #gamma##gamma# modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2)_L(circle times)U(1)_Y chiral operators of order p"4 that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e#gamma# and #gamma##gamma# modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10"-"2 at 90% C.L. Moreover, the information gathered in the e#gamma# mode can be used to reduce the ambiguities of the e"+e"- mode.
The article explains the method of selecting the optimum energy for correcting the energy selectivity of tomographic projection and the optimum length of the crystals corresponding to it when the dual energy method in computerized tomography is used. Results of numerical calculations for actual materials and count results are presented.
Events detected in a shielded plastic scintillation counter occurring in the 26 microsec preceding the arrival of an extensive air shower at ground level with local electron density or = 20 m to the -2 power and the 240 microsec after its arrival have been studied. No significant excess of events (tachyons) arriving in the early time domain have been observed in a sample of 11,585 air shower triggers.
Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.
Research and development activities are reported on absorption spectroscopy, calorimetry, electrolysis, emission spectroscopy, fluorimetry gas chromatography, infrared spectroscopy, liquid chromatography, liquid scintillation counting, mass spectroscopy, microscopy, radiometric analysis, and thermal analysis. A group of miscellaneous projects are also described.
Lead tungstate crystals doped with small fractions of praesodynium or molybdenum have been tested in beams of high-energy electrons. The goal of these tests was to study the effects of such dopants on the capability to separate the signal components deriving from the Cherenkov and scintillation light generated by the beam particles. These studies were carried out in view of the possible application of such crystals in dual-readout calorimeters.
This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.
This paper describes a method for measuring oil consumption in compressors. The oil is labelled with Zn 65. The consumed radioactive oil is retained in an activated carbon filter and its activity is measured continuously with a plastic scintillator detector. Measuring the oil consumption at a given operating levels takes about 15 minutes. At an oil consumption rate of about 1 g/h the measurement errors are of the order of +- 5%. (orig.).
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
A search for tachyons, or other particles detectable by G-M counter tubes or liquid scintillators, arriving during the approximately 100#mu#s immediately preceding extensive air showers (primary energy approximately 10"1"5 eV) has provided no positive evidence for the existence of such particles. (orig.).
A search has been made of tachyons associated with cosmic ray showers of energies about 10"1"5 eV by searching for any precursor effects observed in plastic scintillator detectors. Detection thresholds well below most other similar experiments have been reached but no statistically significant effects have been found.
The near infrared (NIR) upgrade to the Robert Stobie Spectrograph (RSS) on the Southern African Large Telescope (SALT), RSS/NIR, extends the spectral coverage of all modes of the visible arm. The RSS/NIR is a low to medium resolution spectrograph with broadband imaging, spectropolarimetric, and Fabry-Perot imaging capabilities. The visible and NIR arms can be used simultaneously to extend spectral coverage from approximately 3200 A to 1.6 um. Both arms utilize high efficiency volume phase holographic gratings via articulating gratings and cameras. The NIR camera is designed around a 2048x2048 HAWAII-2RG detector housed in a cryogenic dewar. The Epps optical design of the camera consists of 6 spherical elements, providing sub-pixel rms image sizes of 7.5 +/- 1.0 um over all wavelengths and field angles. The exact long wavelength cutoff is yet to be determined in a detailed thermal analysis and will depend on the semi-warm ...
This paper proposes a technique of moving picture overlapping for view simulation by means of the moving picture processing. The continuous pictures of actual natural view gotten from video and the pictures of building structure made by computer graphics (CG) were overlapped. The CG pictures of building structure model were made considering the camera parameters, such as position and direction of camera. In order to analyze the continuously changing camera parameters, optical flows were determined from the view video. Based on these results, the overlapping video was made, in which the building structure was incorporated into the actual view. Furthermore, the proposed technique of moving picture overlapping was applied to the view simulation of transmission line tower. Consequently, it was demonstrated that the overlapped moving pictures can provide information which can not be obtained from the still pictures. It was ...
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for ...
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a powerful tool for ...
We study the production of three gauge bosons (W"+W"-Z"0 and W"+W"-#gamma#) at the next generation of linear e"+e"- colliders operating in the #gamma##gamma# mode. We analyze the total cross sections as well as several kinematical distributions of the final state particles. We find out that a linear e"+e"- machine operating in the #gamma##gamma# mode will produce 5--10 times more three-gauge-boson states compared to the standard e"+e"- mode at high energies.
An electroweak singlet scalar can couple to pairs of vector bosons through loop-induced dimension five operators. Compared to a Standard Model Higgs boson, the singlet decay widths in the diphotons and Z gamma channels are generically enhanced, while decays into massive final states like WW and ZZ are kinematically disfavored. The overall event rates into gammagamma and Z gamma can exceed the Standard Model expectations by orders of magnitude. Such a singlet may appear as a resonant signal in the gammagamma and Z gamma channels, even with a mass above the WW kinematic threshold.
Possible anomalous top-quark couplings induced by SU(2)xU(1) gauge-invariant dimension-6 effective operators were studied in the process of ttbar productions and decays at polarized #gamma##gamma# colliders. Two CP-violating asymmetries, a linear-polarization asymmetry and a circular-polarization asymmetry, were computed including both non-standard ttbar#gamma# and #gamma##gamma#H couplings. An optimal-observable analysis for the process #gamma##gamma##->#ttbar#->#l"#+-# was performed in order to estimate the precision for determination of all relevant non-standard couplings, including the anomalous tbW coupling.
Corrosion testings of model alloys, corresponding by chemical composition to simple and complex-alloyed #gamma#- and #gamma#'-phases of nickel heat-resistant alloys are conducted in sodium sulfate and chloride melts. It is ascertained that heat resistant nickel alloys containing over 50 % of hardening #gamma#'-phase, are subject to disastrous sulfide corrosion (SC). Resistance against SC alloys containing below 50 % of #gamma#'-phase is determined by the resistance of #gamma#-solid solution. 10 refs., 3 figs., 2 tabs.
The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.
A pin hole camera assembly for use in viewing an object having a relatively large light intensity range, for example a crucible containing molten metal in an atomic vapor laser isotope separation (AVLIS) system is disclosed herein. The assembly includes means for optically compressing the light intensity range appearing at its input sufficient to make it receivable and decipherable by a standard video camera. To accomplish this, the assembly utilizes the combination of interference filter and a liquid crystal notch filter. The latter which preferably includes a cholesteric liquid crystal arrangement is configured to pass light at all wavelengths, except a relatively narrow wavelength band which defines the filter's notch, and includes means for causing the notch to vary to at least a limited extent with the intensity of light at its light incidence surface.
For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 [mu]s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.
The decay modes $\\jpsi\\ar\\gamma\\pi^0, \\gamma\\eta$ and $\\gamma\\etap$ are analyzed using a data sample of 58 million $\\jpsi$ decays collected with the BESII detector at BEPC. The branching fractions are determined to be: $Br(\\jpsi\\ar\\gamma\\pi^0)=(3.13^{+0.65}_{-0.44})\\times10^{-5}$, $Br(\\jpsi\\ar\\gamma\\eta)=(11.23\\pm0.89)\\times10^{-4}$, and $Br(\\jpsi\\ar\\gamma\\etap)=(5.55\\pm0.44)\\times10^{-3}$, where the errors are combined statistical and systematic errors. The ratio of partial widths $\\Gamma(\\jpsi\\ar\\gamma\\etap)/\\Gamma(\\jpsi\\ar\\gamma\\eta)$ is measured to be $4.94\\pm0.40$, and the singlet-octet pseudoscalar mixing angle of $\\eta-\\etap$ system is determined to be $\\theta_{P}=(-22.08\\pm0.81)^{\\circ}$.
We calculate the cross sections for the single production of doubly charged dileptons, both scalar and vector, at e"+e"-, e#gamma#, and #gamma##gamma# colliders at #sq root#s =500 GeV and 1 TeV. The e#gamma# mode is by far the most promising---dileptons whose coupling is as weak as #approx#10"-"4#alpha#_e_m can be observed, for masses virtually up to the kinematic limit. Dileptons of mass up to #sq root#s can also be seen in e"+e"- and #gamma##gamma# colliders, for couplings of order #alpha#_e_m. In all three colliders, most of the cross section comes from events in which the only particles detected are e"-e"- (or #mu#"-#mu#"- or #tau#"-#tau#"-), the decay products of the dilepton, yielding an unmistakable experimental signature.
The future e"+e"- linear colliders can also operate in the e#gamma# or #gamma##gamma# modes. In the context of the top-color assisted technicolor (TC2) model, we study the single charged top-pion production process #gamma##gamma# #-># tb-bar#PI#_t"-. The results show that the production rates can reach the level of tens fb with reasonable parameter values. So one can expect that enough signals could be produced in future high-energy linear collider experiments. Furthermore, the flavor-changing (FC) decay mode #PI#_t"- #-># bc-bar is the best channel to detect the charged top pion due to the clean standard model background. With a large number of events and the clean background, the charged top pion should be observable at future linear colliders operating in #gamma##gamma# mode at the TeV energy scale
We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in {gamma}{gamma}{yields}t t-bar {yields}lX/bX for various beam polarizations in order to study possible anomalous t t-bar {gamma}, tbW and {gamma}{gamma}H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and {gamma}{gamma} colliders from the viewpoint of the anomalous-top-quark-coupling determination.
We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in #gamma##gamma##->#t t-bar #->#lX/bX for various beam polarizations in order to study possible anomalous t t-bar #gamma#, tbW and #gamma##gamma#H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and #gamma##gamma# colliders from the viewpoint of the anomalous-top-quark-coupling determination.
CMSX-4 superalloy laser beam welds were investigated by transmission electron microscopy and atom probe field-ion microscopy (APFIM). The weld microstructure consisted of fine (10- to 50-nm) irregularly shaped {gamma}` precipitates (0.65 to 0.75 volume fraction) within the {gamma} matrix. APFIM compositions of the {gamma} and {gamma}` phases were found to be different from those in the base metal. Concentration profiles across the {gamma} and {gamma}` phases showed extensive variations of Cr, Co and Al concentrations as a function of distance within the {gamma} phase. Calculated lattice misfits near the {gamma}/{gamma}` interface in the welds are positive values compared to the negative values for base metal. (orig.).
We study the constraints on the anomalous coupling g_5"Z that can be obtained from the analysis of the reaction #gamma##gamma##->#W"+W"-Z at future linear e"+e"- colliders. We find out that a 0.5 (1) TeV e"+e"- collider operating in the #gamma##gamma# mode can probe values of g_5"Z of the order of 0.15 (4.5x10"-"2) for an integrated luminosity of 10 fb"-"1. This shows that the ability to search for this anomalous interaction of the #gamma##gamma# mode is better than the one of the usual e"+e"- mode, and it is similar to the ability of the e#gamma# mode.
There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.
Brain scintiscanning which was first carried out exclusively 'statical' and only with test substances of limited quality has been replaced nowadays by 'dynamical' camera-sequency-scintiscanning with technetium. This brought considerable progress not only for identifying but also for the differential diagnosis of cerebro-organic processes. Development, methods, and integration of brain scintiscanning in a diagnostical conception are described briefly. (orig.).
In order to meet the needs of remote servicing performed in nuclear power plants, in fuel reprocessing plants and in atomic research centers three companies: - STMI, subsidiary of CEA, EDF and SGN, specialized in decontamination and dismantling, - La Calhene, subsidiary of CEA and SGN, specialized in robotics, - Inspectronic, manufacturer of closed circuit television cameras, have combined to create the Visionic Society, the main objectives of which are observation by television and inspections in radioactive environment.
Oct 24, 1995 ... The photos were made with a Nikon FE and a Sigma 400mm APO f/5.6 lens ... Note: The JPEG images to which the above links point contain subtle ... India on 1995 October 24 with a digital camera and Fe X 6374 ? filter, ...
A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.
imaging of the solar corona began in 1960 via a primitive pinhole camera on a ... IR wavelengths. Such data help us to study in detail the pre-eruptive ...... Schematic picture of flare loops, CME, and the current sheet between ..... As part of NASA's Living With a Star (LWS) program the planned Sentinel mission ...
The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and the variations in ...
The Bureau of Mines has two projects in the remote sensing field as it pertains to mining. One of these is a completed contract that studied the use of aircraft mounted cameras and the results of photogrammetry. The second project is an ongoing contract to study the effectiveness of using an instrumentation system wired to remote data collection station to record embankment data. 6 refs.
Topics addressed include future trends in IR sensors, IR observer performance modeling ... steer a sensor platform with a thermal camera or an air-to-air missile system. .... Skyship and Sentinel series airships. It also outlines the current .... A layout schematic of the UPS is given. AIAA. A93-55494 ...
An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.
Using $\\gamma \\gamma J/\\psi, J/\\psi \\ra e^+ e^-$ and $\\mu^+ \\mu^-$ events from a sample of $14.0\\times 10^6$ $\\psip$ decays collected with the BESII detector, the branching fractions for $\\psip\\ra \\pi^0\\J$, $\\eta\\J$, and $\\psi(2S)\\ar\\gamma\\chi_{c1},\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi$ are measured to be $B(\\psip\\ra \\pi^0\\J) = (1.43\\pm0.14\\pm0.13)\\times 10^{-3}$, $B(\\psip\\ra \\eta\\J) = (2.98\\pm0.09\\pm0.23)%$, $B(\\psi(2S)\\ar\\gamma\\chi_{c1}\\ar\\gamma\\gamma\\jpsi) = (2.81\\pm0.05\\pm 0.23)%$, and $B(\\psi(2S)\\ar\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi) = (1.62\\pm0.04\\pm 0.12)%$.
Interleukin 12 (IL-12) activates natural killer (NK) and T cells with the secondary synthesis and release of interferon-gamma (IFN-gamma) and other cytokines. IL-12-induced organ alterations are reported...Full Text Available
The phagocytic and killing abilities of heifer mammary gland macrophages (M phi) and neutrophils were evaluated after exposure to recombinant bovine interferon-gamma (rBoIFN-gamma) stimulation in vitro....Full Text Available
The radioactive decay of "2"0"3Bi is studied. A level scheme is proposed for "2"0"3Pb on the basis of #gamma#-ray and electron spectra and #gamma#-#gamma# coincidence measurements. The experimental data are compared with theoretical results obtained in a three quasiparticle approximation. (Auth.).
The CKM angle $\\gamma/\\phi_{3}$ had been measured by two B-factories, the PEPII collider for the BaBar experiment and the KEKB collider for the Belle experiments. The present paper reports recent progress in $\\gamma/\\phi_{3}$.
The natural biotic capacity of soils to degrade gamma-hexachlorocyclohexane (gamma-HCH, lindane) was estimated using an enrichment technique based on the ability of soil bacteria to develop on synthetic...Full Text Available
In Pseudomonas paucimobilis UT26, gamma-hexachlorocyclohexane (gamma-HCH) is converted by two steps of dehydrochlorination to a chemically unstable intermediate, 1,3,4,6-tetrachloro-1,4-cyclohexadiene...Full Text Available
The top-color assisted technicolor (TC2) mode predicts the existence of a pair of charged top-pions $\\pi^{\\pm}_t$. In this paper, we study the production of the charged top-pions pair $\\pi^{\\pm}_t$ at next generation $\\gamma\\gamma$ colliders. The results show that the production rates can reach the level of $10^2$ fb with reasonable parameter space. With a large number of events and the clean background, the charged top-pion should be observable at the $\\gamma\\gamma$ colliders. Therefore, our studies can help us to search for charged top-pion, and furthermore, to test the TC2 model.
We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).
We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).
Compton backscattering of laser photons near the interaction point of an e"+e"- or e"-e"- collider can be used to produce a #gamma#-#gamma# or #gamma#-e"- collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e"+e"- colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
Heavy quark production in $\\gamma\\gamma$ collisions is analyzed within the approach to hard collisions of photons recently proposed by the author. In this approach evaluating the cross section $\\sigma(\\gamma\\gamma\\to Q\\bar{Q})$ in the ``next-to-leading order of QCD'' requires the inclusion of direct photon contributions up to the order $\\alpha^2\\alpha_s^2$, whereas in the standard approach direct photon terms only up to the order $\\alpha^2\\alpha_s$ are taken into account. Phenomenological consequences of this difference are discussed.
We investigate the semihard production of neutral pseudoscalar and tensor mesons in high-energy [gamma][gamma] collisions (M=P=[pi][sup 0], [eta], [eta]' or M=T=a[sub 2], f[sub 2], f[sub 2]'). We deal with the exclusive [gamma][gamma][yields]MM' or semi-exclusive [gamma][gamma][yields]MX reactions (X is the hadron jet with not too large mass). The considered transfer momenta are small in comparison with the photon energies and they are large in comparison with the confinement scale. The amplitudes of these processes are determined by the odderon exchange, i.e. three-gluon exchange in the lowest order of perturbative QCD. The cross sections are calculated in this approximation. The possibility of measurements at LEP and at future [gamma][gamma] colliders is discussed. (orig.).
The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.
The production of pairs of doubly charged vector bileptons is studied at future #gamma##gamma# colliders. The unpolarized cross section for the #gamma##gamma##->#Y"-"-Y"+"+ subprocess is analytically calculated and convoluted to predict the number of events in the complete e"+e"-#->##gamma##gamma##->#Y"-"-Y"+"+ process. The gauge or nongauge character of the vector bilepton Y"#+-#"#+-# is discussed. It is found that, as a consequence of its spectacular signature, as it decays dominantly into two identical charged leptons, and also due to its charge contents, which significantly enhance the cross section, the detection of this class of particles with mass in the sub-TeV region can be at the reach of these colliders. The model-independent nature of our results is stressed.
The possibility of gamma-absorption identification of the analyzed substance is considered. the basic provisions of the proposed method are concentrated on the example of carbohydrates and hydrocarbons. The above method is tested experimentally on polyethylenes and polystyrene
Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and limitations should be ...
The coupled neutron-gamma cross section libraries BUGLE-80 and SAILOR are compared, with focus on gamma production and transport and its sensitivity to the thermal component of the neutron flux. In addition, the importance of the prompt versus delayed components of the gamma source is addressed. Although BUGLE-80 shows some discrepancies in the core region, the two libraries demonstrate similar capability in the vicinity of the pressure vessel and beyond. The delayed fission product gammas from the core have little impact on the local gamma fluxes beyond the pressure vessel. Although thermal neutron capture is the dominant component of the gamma source, there is little sensitivity of the gamma source to uncertainties in the thermal neutron cross sections, due to compensating effects which tend to keep the thermal neutron capture rate ...
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the accelerator. This is compared with an idealized model simulation ...
Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. Some measurements were non-contact, involving short distances ...
State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method was developed to permit rapid, accurate ...
X-ray fluorescence analysis was used to determine the zinc content of the ''Perilacin'' powder and the ZnO content of the ''Epiderman-pix'' powder. The characteristic Ksub(#alpha#) line of zinc was excited using a "1"4"7Pm/Mo source (10"7 s"-"1) and the molybdenum Ksub(#alpha#) line (17.47 keV). 4 to 5% Zn and 45 to 49% ZnO were determined with a NaI(Tl) scintillation detector. The radiation intensity was found to decrease with particle size. (M.K.).
Passage of neon gas through activated charcoal is planned to be the primary method of removing impurities from the liquid neon scintillator in the CLEAN experiment. In order to quantify this technique, the breakout curves for hydrogen, nitrogen, argon and krypton impurities in neon-saturated activated charcoal were measured. Adsorption coefficients and the number of theoretical stages were measured for hydrogen in the temperature range between 300 and 80 K, nitrogen between 300 and 200 K, and argon between 300 and 190 K. The adsorption coefficient for krypton was measured at 300 K.
The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.
The Electromagnetic Calorimeter (ECAL) of the AMS-02 experiment is a lead-scintillating fibers sampling calorimeter characterized by high granularity that allows to image the longitudinal and lateral showers development, a key issue to provide high electron/hadron discrimination. The light collection system and the FE electronics are designed to let the calorimeter operate over a wide energy range from few GeV up to 1 TeV. A full-scale prototype of the e.m. calorimeter was tested at CERN in October 2001 using electrons and pions beams with energy ranging from 3 to 100 GeV. Effective sampling thickness, linearity and energy resolution were measured. (8 refs).
Producing nuclear energy in order to reduce anthropic CO{sub 2} emission and to meet high energy demand, implies three conditions to the nuclear plants of the IV. generation: safety improvements, radioactive waste minimization, and fuel breeding for a sustainable use of the resources. The Thorium fuel cycle used in Molten Salt Reactors seems promising. Many numerical studies based on probabilistic codes are carried out in order to analyse the behaviour of such reactors. Nevertheless, one of the most important parameters is badly known: the alpha ratio of {sup 233}U, ratio of the neutron capture cross section to fission one for {sup 233}U. This key-parameter is necessary to calculate the breeding ratio and thus, the deployment capacities of those reactors. This Ph-D thesis was intended to prepare a precise measurement of the alpha ratio of {sup 233}U between 1 eV and 10 keV. Preliminary measurements have been performed on the experimental platform PEREN. This experimental environment is ...
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.
The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.
We have implemented a virtual Young's double slit experiment for hard X-ray photons with micro-fabricated bi-prisms. We observe fringe patterns with a scintillator, and quantify interferograms by detecting X-ray fluorescence from a scanned 30nm Cr metal film. The observed intensities are best modeled with a near-field, Fresnel analysis. The maximum fringe number in the overlap region is proportional to the ratio of real to imaginary parts refractive index of the prism material. The horizontal and vertical transverse coherence lengths at beamline APS 8-ID are measured.
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, located in the neutron beam, is estimated to {approx}2.5 MHz. The useful countrate for this case is ...
The heavy Higgs bosons H,A of the minimal supersymmetric extension of the Standard Model can be produced as resonances in high-energy #gamma##gamma# colliders. Prospects of the search for these particles in bb-bar and neutralino-pair final states are studied in this report. Heavy Higgs bosons can be found with masses up to about 70-80% of the initial e"+e"- collider energy for moderate values of tan #beta#, i.e. in areas of the parameter space not accessible at other colliders.
Future #gamma##gamma# colliders allow the production of the heavy neutral MSSM Higgs bosons H and A as single resonances. The prospects of finding these particles in the bb-bar and the neutralino-pair final states have been analyzed. The H, A bosons can be discovered for medium values of tan #beta# with masses up to 70-80% of the initial e"#+-#e"- c.m. energy. This production mode thus covers parts of the supersymmetric parameter space that are not accessible at other colliders.
We study heavy physics effects on the Higgs production in #gamma##gamma# fusion using the effective Lagrangian approach. We find that the effects coming from new physics may enhance the standard model predictions for the number of events expected in the final states b-barb, WW, and ZZ up to one order of magnitude, whereas the corresponding number of events for the final state t-bart may be enhanced up to two orders of magnitude.
We investigate the scope of all relevant production modes of charged Higgs bosons in the MSSM, with mass larger than the one of the top quark, at future Linear Colliders operating in {gamma}{gamma} mode at the TeV energy scale. Final states with one or two H{sup {+-}} bosons are considered, as produced by both tree- and loop-level interactions. (orig.)
We investigate the scope of all relevant production modes of charged Higgs bosons in the MSSM, with mass larger than the one of the top quark, at future Linear Colliders operating in #gamma##gamma# mode at the TeV energy scale. Final states with one or two H"#+-# bosons are considered, as produced by both tree- and loop-level interactions. (orig.)
The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.
This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.
We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes {gamma}{gamma}{yields}4f and {gamma}{gamma}{yields}4f{gamma} in the standard model and extensions thereof by an effective {gamma}{gamma}H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes {gamma}{gamma}{yields}4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size ...
We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes #gamma##gamma##->#4f and #gamma##gamma##->#4f#gamma# in the standard model and extensions thereof by an effective #gamma##gamma#H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes #gamma##gamma##->#4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size of ...
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
Carbide reactions occurring in a precipitation-hardening gamma/gamma-prime Ni-Cr alloy during prolonged high-temperature aging are investigated experimentally. It is found that the decomposition of primary MC carbides, which is accompanied by the precipitation of M23C6 particles, may lead to void nucleation and growth. The effect of carbide transformations on the residual properties of the material at temperatures above the equicohesion temperature is observed at the late stages of aging only. 6 references.
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
Possible anomalous top-quark couplings induced by SU(2)xU(1) gauge-invariant dimension-6 effective operators were studied in the process of ttbar productions and decays at polarized {gamma}{gamma} colliders. Two CP-violating asymmetries, a linear-polarization asymmetry and a circular-polarization asymmetry, were computed including both non-standard ttbar{gamma} and {gamma}{gamma}H couplings. An optimal-observable analysis for the process {gamma}{gamma}{yields}ttbar{yields}l{sup {+-}} was performed in order to estimate the precision for determination of all relevant non-standard couplings, including the anomalous tbW coupling.
Physical processes in the region of laser conversion for the next Linear Colliders (NLC) are discussed. The main goal of this conversion is to obtain high-energy intense #gamma# beams for #gamma#e and #gamma##gamma# colliders. This conversion has important by-products: (i) one can observe here effect of nonlinear QED (in a strong external field)-production of e"+e"- pairs by a high-energy photon and emission of very high-energy photons by an electron; (ii) one can produce and observe here the invisible axion in colliding #gamma#_0e beams. The NQED effects also result in variation of the spectra of high-energy photons and an additional background. 12 refs., 12 figs., 1 tab.
Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.
The short review of complete tree level calculations for three particle final states production at the future e"+e"-, #gamma#e and #gamma##gamma# colliders is presented. The results obtained with the help of CompHEP system for total cross sections and other characteristics of processes in the energy range 0.1-2 TeV are summarized and their comparison with the results of different approaches is discussed. In particular we are interested in the processes of W, Z and H boson production. The reactions under consideration are especially interesting in connection with probing of new couplings, searching for new particle signals and as an important backgrounds to these experiments. The main subjects described are basic reactions rates (sections 2,3), Higgs production in #gamma#e collisions (section 4), the possibilities of testing some four vector bosons interaction vertices and Higgs-fermion coupling (section 5), the process of ...
We consider single production of leptoquarks (LQ's) at e"+e- and #gamma##gamma# colliders, for two values of the center-of-mass energy: #sq root#s =500 GeV and 1 TeV. We find that LQ's which couple within the first generation are observable for LQ masses almost up to the kinematic limit, both at e"+e- and #gamma##gamma# colliders, for an LQ coupling strength equal to #alpha#_e_m. The cross sections for single production of second- and third-generation LQ's at e"+e- colliders are too small to be observable. In #gamma##gamma# collisions, on the other hand, second-generation LQ's with masses much larger than #sq root#s /2 can be detected. However, third-generation LQ's can be seen at #gamma##gamma# colliders only for masses at most #approx# #sq root#s /2, making their observation more probable via the pair production mechanism.
1. Gamma globulin metabolism and distribution were studied employing rabbit gamma globulin (RGG)I(131) 24 times in 13 control rabbits. Similar studies were performed before and during the ananmestic response in 4 rabbits previously sensitized with a polyvalent pneumococcal vaccine. 2. During the ananmestic response, gamma-globulin levels increased from 1.0 to 6.0 gm/100 ml, and the gamma-globulin pool increased from 0.7 to 4.7 gm/kg. There was no change in the intravascular-extravascular partition of gamma globulin. 3. Gamma globulin degradation increased from 0.06 to 0.33 gm/kg/day during the 28 days of the immunization period while gamma globulin synthesis increased even further to average 0.47 gm/kg/day. Following the attainment of elevated gamma globulin levels the fractional rate of RGG-I(131) turnover increased ...
We consider the possibility of detecting a heavy Higgs boson (m_H>2m_Z) in proposed #gamma##gamma# colliders through the semileptonic mode #gamma##gamma##->#H#->#ZZ#->#q bar ql"+l-. We show that due to the nonmonochromatic nature of the photon beams produced by the laser-backscattering method, the resultant cross section for Higgs production is much smaller than the on-resonance cross section, and generally decreases with increasing collider energy. Although continuum ZZ production is expected to be negligible, we demonstrate the presence of, and calculate sizable backgrounds from, #gamma##gamma##->#l"+l-Z,q bar qZ, with Z#->#q bar q,l"+l-, respectively, and #gamma##gamma##->#t bar t#->#b bar bl"+l-#nu# bar #nu#. This channel may be used to detect a Higgs boson of mass m_H up to around 350 GeV at a 0.5 TeV e"+e- collider, assuming a nominal yearly luminosity of 10--20 fb"-"1.
We investigate the effect of anomalous gamma-W-W couplings in e-gamma --> nu W through the angular and energy spectrum of the secondary leptons. Within the narrow-width approximation, a semi-analytical study of the secondary lepton energy-angle double distribution is considered. Utility of observables derived from this is demonstrated by considering the anomalous coupling, delta-kappa-gamma. Results of our investigation for typical ILC machine considered at Ecm = 300-1000 GeV re-affirms potential of this collider as a precision machine.
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
The notion of intuitionistic fuzzy set was introduced by Atanassov as a generalization of the notion of fuzzy set. In this paper we apply this concept of Atanassov to ideals, prime ideals and semiprime ideals of gamma semigroups in order to obtain some characterization theorems. We also introduce the notion of Atanassov's intuitionistic fuzzy ideal extension in a gamma semigroup and investigate some of their important properties. A regular gamma semigroup has been characterized in terms of Atanasov's intutionistic fuzzy ideal. Characterization of prime ideal of a gamma semigroup has also been obtained in terms of Atanassov's intutionistic fuzzy ideal extension.
Previous flow regime studies have been for horizontal, vertical, and inclined pipe flow. As such, only a few studies have been performed on bundle geometries. The present paper examines the flow regimes for a vertical hexagonal flow channel with and without a finned fuel bundle. This type of a 36 finned rod hexagonal fuel bundle in parallel hexagonal flow channels is used in a MAPLE (Multi- purpose Applied Physics Lattice Experimental) type nuclear reactor. An experiment apparatus was designed consisting of the flow channel, inlet plenum and an air-water separator. The inlet plenum is used to provide a uniform mixture of air and water before entering the hexagonal flow channel. A turbine flow meter is used to determine the water flow rate. The turbine flow meter is calibrated for a low flow range and limits the measurable flow to 50 l/min. Flow pattern observation is determined by a SONY video camera, Real-Time Neutron Radiography, pressure transducer and ...
This work presents the development of a streak camera 'jitter free' sweep unit synchronized on a femtosecond laser. This application of high voltage photoconductive switches ('High voltage Auston switch') yields subpicosecond resolution for accumulated images on streak camera on a few hundreds micro joule femtosecond laser. Two others applications of these photoconductive switches are studied: - ultrafast optical commutation by a Pockels cell directly driven by a photoconductive switch (rising edge < 100 ps and jitter < 2 ps), - laser pulse energy self-stabilization experimentally proving that driving a Pockels cell by a photoconductive switch can increase the stability of the laser pulse energy from 7 % to 0.7 % rms. Additionally, the application of the acoustic-optical programmable dispersive filter (Dazzler) to the self referenced spectral phase measurement is presented. As these measurements ...
Optical sections of the cornea are obtained by illumination with a collimated beam expanded in a fan shape by a small rotary cylindrical lens. The light diffused from the cornea is observed by two cameras and processed in order to yield the surfaces' profiles. The optical system used to project a thin rotating line on the cornea consists of a white light source provided with optical fiber bundle output which is first conditioned by a set of lenses so that it would produce a spot on the cornea. A small cylinder lens is used to expand the beam in one direction so that a thin line illuminates the cornea, rather than a spot. The cylinder lens is provided with motor driven rotation about an axis normal to its own in order to rotate the line on the cornea such that the projected line scans the whole cornea; the illuminator is completed with a slit aperture. The cornea is not perfectly transparent, scattering some of the light that traverses it; this fact is used for its ...
The airborne traffic monitoring system forms a novel technology of detecting vehicle motion. An optical digital camera located on an airborne platform produces a series of images which then are processed to recognized the fixed vehicles. In this way the video data are converted into the time sequence of frames containing the vehicle coordinates. In the present work a three-frame algorithm is developed to identify the succeeding vehicle positions. It is based on finding the neighboring points in the frame sequence characterized by minimal acceleration. To verify and optimize the developed algorithm a ``Virtual Road'' simulator was created. Finally available empirical data are analyzed using the created algorithm.
As a direct result of its interest in the use of robotics within active plants, British Nuclear Fuels Ltd. (BNFL) has adopted a positive attitude toward both national and European initiatives in this area. During the early operation of the Sellafield reprocessing plant, the process vessels and cell voids were monitored using simple pole and camera combinations. In 1985, BNFL embarked on the provision of a series of machines intended to satisfy the advancing needs for inspection while increasing the level of expertise within the company in this important area. DIMAN 1, DIMAN 2, RODMAN, REPMAN, and RAFFMAN remote handling and robotic machines are described.
Advances in the development of several electrooptic shutter devices utilizing the quadratic electrooptic effect of lead lanthanum zirconate titanate (PLZT) ceramic wafers are described. Aperture sizes utilized in these PLZT devices ranged from 25 ..mu..m to 0.25 m. Practical applications of the shutters discussed in this paper include eye protection in military and industrial applications, a goggle-type device with dual synchronously operated PLZT shutters for use in a stereoscopic three-dimensional TV display, an electrically controlled variable density filter for use with vidicon tubes, a large-aperture photographic shutter for image motion compensation cameras, and a page composer for use in a holographic memory system.
Positron emission tomography (PET) and X-ray computed tomography (CT) performed with PET/CT cameras allow us to obtain concurrently information on the presence and degree of alterations of myocardial perfusion and metabolism and on coronary arteries calcification. Furthermore, by gated myocardial perfusion studies, PET may provide crucial information on regional coronary blood flow reserve and endothelial dysfunction. A number of recent papers provide some insight on the potential of PET/CT in cardiology and in the assessment of various cardiovascular diseases including various types of vasculitis and metabolic diseases.
This paper explains how mine operators are taking a closer look at the power of explosives and how primary breakage affects other open-pit mining costs. Slurries have overcome most of the disadvantages attributed to them in their early years and may replace Anfo. Effective blasting is the key to an efficient, low-cost mining operation. Reviews are presented on research in crater studies, computer-aided design, the expanding gas theory, and high-speed motion picture cameras that show the importance of shock energy in fracturing the rock interfaces throughout the burden. The paper concludes with MSHA-approved courses in blasting offered throughout the US.
The Monte Carlo ray-tracing method is applied and coupled with optical properties to predict the radiation performance of solar concentrator/cavity receiver systems. Several different cavity geometries are compared on the radiation performance. A flux density distribution measurement system for dish parabolic concentrators is developed. The contours of the flux distribution for target placements at different distances from the dish vertex of a solar concentrator are taken by using an indirect method with a Lambert and a charge coupled device (CCD) camera. Further, the measured flux distributions are compared with a Monte Carlo-predicted distribution. The results can be a valuable reference for the design and assemblage of the solar collector system.
This report describes an improved method of remotely identifying irradiated nuclear fuel assemblies. The method uses existing in-cell TV cameras to input an image of the notch-coded top of the fuel assemblies into a computer vision system, which then produces the identifying number for that assembly. This system replaces systems that use either a mechanical mechanism to feel the notches or use human operators to locate notches visually. The system was developed for identifying fuel assemblies from the Fast Flux Test Facility (FFTF) and the Clinch River Breeder Reactor, but could be used for other reactor assembly identification, as appropriate.
Neon 19, a 17-second positron-emitting radioelement, is produced continously by 23 MeV alpha particle bombardment of oxygen. For a 12 ..mu..A particle current the method of preparation described delivers 14 mCi of neon 19 per min to the functional exploration room. The radiochemically pure radioactive gas is diluted in air and breathed continously by the patient lying under a positron tomographic camera. The regional lung ventilation distribution is obtained on 2 cm thick sections of organ with a transverse resolution of 17 mm. Quantification of the ventilation output per unit lung volume is contemplated.
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
The signature of the negative snakes from the soft X-ray cameras is very similar to the more usual snakes except that the localised region of the snake has, compared with its surroundings, decreased rather than increased emission. Circumstances where negative snakes have been seen are reviewed. The negative snake appears as a region of increased resistance and of increased impurity density. The relationship between the shear and the current perturbation is shown, and it seem probable that the magnetic shear is reversed at the point of the negative snake, i.e. that q is decreasing with radius. 6 refs., 6 figs.
We have developed a novel laser ray-tracing method to measure aberrations in optical systems. It consists of delivering narrow laser pencils (by a laser scanner), recording the spots that are formed on the image plane (with a CCD camera), and computing the position of each centroid. This approach could be considered an experimental (approximate) implementation of standard numerical ray tracing. Several tests and experiments, including a direct comparison with a Hartmann-Shack wave-front sensor, provided highly satisfactory results that confirmed the validity of the method and revealed potential advantages. PMID:18073906
During a number of years research and development projects have been made to present methods of monitoring the grate in a grate fired boiler. The monitoring is interesting in order to be able to increase efficiency, increase burn-out of ash, improve the status of emissions, improve transportation of ash and fuel through the furnace, reduce costs for operation and maintenance, handle greater loads etc. Improvement of the combustion has been concentrated to the development of the gas phase combustion. In the past few years the computer development has progressed rapidly and the use of optical monitoring methods have been made possible for monitoring grates. To analyse state of the art of optical grate monitoring systems three different methods have been used, literature search, inquiry where plant owners were asked if they have used grate monitoring systems and if so what experiences they have, and interviews with scientists and users. The inquiry investigation was made during spring ...
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.
A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).
An algorithm for pose and motion estimation using corresponding features in images and a digital terrain map is proposed. Using a Digital Terrain (or Digital Elevation) Map (DTM/DEM) as a global reference enables recovering the absolute position and orientation of the camera. In order to do this, the DTM is used to formulate a constraint between corresponding features in two consecutive frames. The utilization of data is shown to improve the robustness and accuracy of the inertial navigation algorithm. Extended Kalman filter was used to combine results of inertial navigation algorithm and proposed vision-based navigation algorithm. The feasibility of this algorithms is established through numerical simulations.
We develop a new cavity with a mode similar to TE13 to produce microwave plasma, named APMPS II, which is able to produce a mass of air plasma with diameter of around 6 cm, equipped with about 3 kW input power under one atmosphere. The plasma seems to be homogeneous without significant filamentous discharge as observed by common camera device. We present the theory of this cavity, show the distribution of electric field of several planes inside the cavity and give some experimental results. (authors)
The future e{sup +}e{sup -} linear colliders can also operate in the e{gamma} or {gamma}{gamma} modes. In the context of the top-color assisted technicolor (TC2) model, we study the single charged top-pion production process {gamma}{gamma} {yields} tb-bar{pi}{sub t}{sup -}. The results show that the production rates can reach the level of tens fb with reasonable parameter values. So one can expect that enough signals could be produced in future high-energy linear collider experiments. Furthermore, the flavor-changing (FC) decay mode {pi}{sub t}{sup -} {yields} bc-bar is the best channel to detect the charged top pion due to the clean standard model background. With a large number of events and the clean background, the charged top pion should be observable at future linear colliders operating in {gamma}{gamma} mode at the TeV energy scale.
The O({alpha}) electroweak radiative corrections to {gamma}{gamma}{yields}WW{yields}4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for {gamma}{gamma}{yields}4f+{gamma}. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer {gamma}{gamma} - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over ...
The O(#alpha#) electroweak radiative corrections to #gamma##gamma##->#WW#->#4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for #gamma##gamma##->#4f+#gamma#. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer #gamma##gamma# - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a convolution over ...
We study the constraints on the anomalous coupling {ital g}{sub 5}{sup {ital Z}} that can be obtained from the analysis of the reaction {gamma}{gamma}{r_arrow}{ital W}{sup +}{ital W}{sup {minus}}{ital Z} at future linear {ital e}{sup +}{ital e}{sup {minus}} colliders. We find out that a 0.5 (1) TeV {ital e}{sup +}{ital e}{sup {minus}} collider operating in the {gamma}{gamma} mode can probe values of {ital g}{sub 5}{sup {ital Z}} of the order of 0.15 (4.5{times}10{sup {minus}2}) for an integrated luminosity of 10 fb{sup {minus}1}. This shows that the ability to search for this anomalous interaction of the {gamma}{gamma} mode is better than the one of the usual {ital e}{sup +}{ital e}{sup {minus}} mode, and it is similar to the ability of the {ital e}{gamma} mode.
In this report, I surveyed physics potential of the {gamma}{gamma} option of a linear e{sup +}e{sup -} collider with the following questions in mind: What new discovery can be expected at a {gamma}{gamma} collider in addition to what will be learned at its 'parent' e{sup +}e{sup -} linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e{sup -} beams, we find that a {gamma}{gamma} collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e{sup -}e{sup -} system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a {gamma}{gamma} collider. CP property ...
In this report, I surveyed physics potential of the #gamma##gamma# option of a linear e"+e"- collider with the following questions in mind: What new discovery can be expected at a #gamma##gamma# collider in addition to what will be learned at its 'parent' e"+e"- linear collider? By taking account of the hard energy spectrum and polarization of colliding photons, produced by Compton back-scattering of laser light off incoming e"- beams, we find that a #gamma##gamma# collider is most powerful when new physics appears in the neutral spin-zero channel at an invariant mass below about 80% of the c.m. energy of the colliding e"-e"- system. If a light Higgs boson exists, its properties can be studied in detail, and if its heavier partners or a heavy Higgs boson exists in the above mass range, they may be discovered at a #gamma##gamma# collider. CP property of the scalar sector can be explored in detail by ...
The energy and intensity of gamma rays as seen in thermal neutron capture are presented. Only those (n,..cap alpha..), E = thermal, reactions for which the residual nucleus mass number is greater than or equal to 45 are included. These correspond to evaluations published in Nuclear Data Sheets. The publication source data are contained in the Evaluated Nuclear Structure Data File (ENSDF). The data presented here do not involve any additional evaluation. Appendix I lists all the residual nuclides for which the data are included here. Appendix II gives a cumulated index to A-chain evaluations including the year of publication. The capture gamma ray data are given in two tables - the Table 1 is the list of all gamma rays seen in (n,..gamma..) reaction given in the order of increasing energy; the Table II lists the gamma rays according to the nuclide.
We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process {gamma}{gamma}{yields}tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future {gamma}{gamma} colliders for small values of tan {beta}. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)
We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process #gamma##gamma##->#tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future #gamma##gamma# colliders for small values of tan #beta#. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)
"1"0"1Mo is one of the key nuclides in diagnosing fission burn-up. However, it's difficult to measure its nuclear decay data due to its short half-life. Present study concerns in the measurements of #gamma#-ray emission probabilities, P_#gamma#, of "1"0"1Mo and "1"0"1Tc using the balance of scheme method and the entire process recording. The P_#gamma# of "1"0"1Mo by the entire process recording is about 5% lower than that by using the balance of scheme method. The P_#gamma# of "1"0"1Tc using the two methods agree each other very well. So, it seems the #gamma#-ray emission probabilities as well as measurement method still need study further for "1"0"1Mo. (authors)
The resonant scattering of bremsstrahlung #gamma#-rays by a SrCO_3 target has been studied for #gamma#-ray energies of 5-11 MeV. Six #gamma#-transitions of energies between 6-8 MeV, which indicate six resonant states in "8"8Sr, were observed. The relative intensities of the resonantly scattered #gamma#-rays at 125 and 150"0 were found to be compatible only with the assignment of spin 1 to the six states. Radiative widths of the resonant states were deduced. The possibility that these states are components of the giant M1 resonance in "8"8Sr is discussed. (orig.).
The {rvec n} + p {yields} d + {gamma} experiment under construction at LANSCE studies the weak interaction between neutrons and protons. The experiments will measure the directional dependence of the parity-violating {gamma}-ray asymmetry, A{sub {gamma}}, in the polarized cold neutron capture by para-hydrogen. The goal is to measure A{sub {gamma}} with uncertainty of 0.5 x 10{sup -8}, 10% of its predicted value. A{sub {gamma}} primarily isolates the {Delta}I = 1 component of the hadronic weak interaction and thus will determine the long-range weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. The experiment is carefully designed for the LANSCE pulsed spallation neutron source to achieve the proposed statistical precision and to control systematic errors. We discuss the experiment and its status.
One of the main challenges for a high energy {gamma}{gamma} collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).
One of the main challenges for a high energy #gamma##gamma# collider is the high repetition rate required for the laser-electron-beam collisions to convert into high energy gamma beams. State-of-the-art, high power lasers have a much lower repetition rate than that of the electron pulses. It is therefore highly desirable that the same laser pulse can be reused. As an example, for NLC where beams collide at 120 Hz, within each collision cycle there are 90 electron bunches separated by 1.4 ns between successive bunches. We show, by invoking a recently invented laser optical box, that the laser pulses can be reused for the entire train of bunches within each collision cycle. ((orig.)).
Higgs mediated flavor violating electromagnetic interactions, induced at the one-loop level by a nondiagonal Hf_if_j vertex, with f_i and f_j charged leptons or quarks, are studied within the context of a completely general effective Yukawa sector that comprises SU_L(2)xU_Y(1)-invariant operators of up to dimension-six. Exact formulae for the one-loop #gamma#f_if_j and #gamma##gamma#f_if_j couplings are presented and their related processes used to study the phenomena of Higgs mediated lepton flavor violation. The experimental limit on the #mu##->#e#gamma# decay is used to derive a bound on the branching ratio of the #mu##->#e#gamma##gamma# transition, which is 6 orders of magnitude stronger than the current experimental limit. Previous results on the #tau##->##mu##gamma# and #tau##->##mu##gamma##gamma# decays are reproduced. The possibility of ...
This talk summarizes recent progress in top quark physics studies for high energy linear electron-positron colliders as presented at the LCWS2000 Workshop at Fermilab. New results were presented for top pair production at threshold and in the continuum, as well as for top production at #gamma##gamma# colliders.
The present status of theoretical description of deep-inelastic lepton-nucleon as well as large angle Bhabha scattering with account for radiative corrections in the leading and next-to-leading approximations are reviewed. Also considered is a build-up principle and physical programme of the photon-photon colliders
We study double Higgs boson production at future linear colliders while paying special attention to the option of high-energy and high-luminosity photon beams. The main purpose is to examine the feasibility of e"+e"-, #gamma#e, and #gamma##gamma# colliders in order to establish bounds on the value of triple Higgs coupling, which could be crucial for understanding a spontaneous breaking mechanism. We consider mainly those cases of light and intermediate Higgs bosons, including an analysis of the electroweak backgrounds. The mass range M_H#approx#M_Z is discussed separately. It is shown that for a light Higgs boson the H"3 coupling can be visible, even at a future linear e"+e"- collider at 500 GeV. For an intermediate Higgs boson, a collider with TeV energies is suitable for investigations. We estimate the bounds on the anomalous H"3 coupling which can be experimentally established at future linear colliders. copyright 1996 The American Physical ...
I review the physic prospects for high energy photon photon colliders, emphasizing results presented at the LBL GammaGamma Collider Workshop. Advantages and difficulties are reported for studies of QCD, the electroweak gauge sector, supersymmetry, and electroweak symmetry breaking.
I review the physics prospects for high energy photon photon colliders, emphasizing results presented at the LBL GammaGamma Collider Workshop. Advantages and difficulties are reported for studies of QCD, the electroweak gauge sector, supersymmetry, and electroweak symmetry breaking. ((orig.)).
I review the physic prospects for high energy photon photon colliders, emphasizing results presented at the LBL GammaGamma Collider Workshop. Advantages and difficulties are reported for studies of QCD, the electroweak gauge sector, supersymmetry, and electroweak symmetry breaking.
I review the physics prospects for high energy photon photon colliders, emphasizing results presented at the LBL GammaGamma Collider Workshop. Advantages and difficulties are reported for studies of QCD, the electroweak gauge sector, supersymmetry, and electroweak symmetry breaking. ((orig.)).
We summarize some initial results in our investigation of the nuclear physics issues of gamma-ray lasers. We describe what is known thus far from existing experimental data and illustrate how theoretical models may be employed for systematic searches of candidate nuclei.
We summarize some initial results in our investigation of the nuclear physics issues of gamma-ray lasers. We describe what is known thus far from existing experimental data and illustrate how theoretical models may be employed for systematic searches of candidate nuclei.
Detailed level and decay schemes and the experimental reaction and decay data on which they are based are presented for nuclei with mass number A = 242; the experimental data are evaluated. Adopted values for level and ..gamma..-ray energies, ..gamma..-intensities, as well as other nuclear properties are given.
Detailed level and decay schemes and the experimental reaction and decay data on which they are based are presented for nuclei with mass number A = 242; the experimental data are evaluated. Adopted values for level and #gamma#-ray energies, #gamma#-intensities, as well as other nuclear properties are given.
Given an invariant gauge potential and a periodic scalar potential \\tilde{V} on a Riemannian manifold \\tilde{M} with a discrete symmetry group \\Gamma, consider a \\Gamma-periodic quantum Hamiltonian \\tilde{H}=-\\tilde{\\Delta}_{B}+\\tilde{V} where \\tilde{\\Delta}_{B} is the Bochner Laplacian. Both the gauge group and the symmetry group \\Gamma can be noncommutative, and the gauge field need not vanish. On the other hand, \\Gamma is supposed to be of type I. To any unitary representation \\Lambda of \\Gamma one relates a Hamiltonian H^{\\Lambda}=-\\Delta_{B}^{\\Lambda}+V on M=\\tilde{M}/\\Gamma where V is the projection of \\tilde{V} to M. We describe a construction of the Bloch decomposition of \\tilde{H} into a direct integral whose components are H^{\\Lambda}, with \\Lambda running over the dual space \\hat{\\Gamma}. The evolution ...
We present the complete next-to-leading order (NLO) QCD corrections to the top quark associated with $\\gamma$ production induced by model-independent $tq\\gamma$ and $tqg$ flavor-changing neutral-current (FCNC) couplings at hadron colliders, respectively. We also consider the mixing effects between the $tq\\gamma$ and $tqg$ FCNC couplings for this process. Our results show that, for the $tq\\gamma$ couplings, the NLO QCD corrections can enhance the total cross sections by about 50% and 40% at the Tevatron and LHC, respectively. Including the contributions from the $tq\\gamma$, $tqg$ FCNC couplings and their mixing effects, the NLO QCD corrections can enhance the total cross sections by about 50% for the $tu\\gamma$ and $tug$ FCNC couplings, and by about the 80% for the $tc\\gamma$ and $tcg$ FCNC couplings at the LHC, respectively. Moreover, ...
The NS together with a gamma ray sensor make up the Gamma- Ray and ... A simplified view of the interactions between incoming cosmic rays and the .... held in Huntsville, Alabama, at the U.S. Space and Rocket Center on January 2830. ...
Evidence is presented for a distinctive type of hippocampal synaptic modification [previously described for a molluscan gamma-aminobutyric acid (GABA) synapse after paired pre- and postsynaptic excitation]:...Full Text Available
In 1959, the Test Manager's Committee to Establish Fallout Doses calculated estimated external gamma exposure at populated locations based upon measurements of external gamma-exposure rate. Using these calculations and estimates of population, we have tabulated the collective estimated external gamma exposures for communities within established fallout patterns. The total collective estimated external gamma exposure is 85,000 person-R. The greatest collective exposures occurred in three general areas: Saint George, Utah; Ely, Nevada; and Las Vegas, Nevada. Three events, HARRY (May 19, 1953), BEE (March 22, 1955), and SMOKY (August 31, 1957), accounted for over half of the total collective estimated external gamma exposure. The bases of the calculational models for external gamma exposure of ''infinite exposure,'' ...
We give a summary of the discussions in Working Group V of the CKM2010 workshop dealing with determinations of the angle gamma of the unitarity triangle of the Cabibbo-Kobayashi-Maskawa matrix from B-meson decays into charmed final states.
The motivation, feasibility and potential for two unconventional collider concepts - the Gamma-Gamma Collider and the Muon Collider - are described. The importance of the development of associated technologies such as high average power, high repetition rate lasers and ultrafast phase-space techniques are outlined.
The dielectrical properties of organosilicon sealants have been studied in the wide range of temperatures in the low and radio frequencies range. The effect of thermal treatment and #gamma#-irradiation on these properties is discussed.
Massive particle candidates for dark matter provide a potentially observable signature by virtue of their annihilations in the galactic halo at a known but model-dependent rate. Possible signatures are described, including cosmic ray antiproton and gamma-ray production. (orig.).
Neutron diffraction was used to monitor elastic strains during in situ tension testing of a directionally solidified (DS) superalloy at 900 deg. C. Changes in misfit and thermal expansion coefficients of individual phases were obtained. In the {gamma} phase, it is demonstrated that elastic strains saturate at 350 MPa, which is well below the yield strength of the alloy. This is interpreted as the onset of dislocation glide through less stressed vertical channels. The critical resolved shear stress (CRSS) of {gamma} is found to be 143 {+-} 11 MPa, in agreement with a calculated CRSS that is dominated by Orowan bowing of dislocations through nanoscale-wide {gamma} channels. This provides confirmation of Orowan bowing in plasticity/creep of the {gamma} phase. Implications of CRSS and misfit in a 'threshold stress' for creep and rafting are discussed. The CRSS of ...
Recent results using B_s -> J/Psi phi decays for measuring the CP violating phase, phi_s, and the decay width difference for the two mass eigenstates, Delta Gamma_s, are presented from the CDF and D0 experiments at the Fermilab Tevatron collider.
In nuclear fuel with a burn-up of 33 kg/t U and 52 kg/t U 15 transuranium nuclides /sup 237/Np to /sup 246/Cm have been determined by alpha and gamma spectroscopy after radiochemical separation.
Gamma interferon (IFN-γ) and the cellular responses induced by it are essential for controlling mycobacterial infections. Most patients bearing an IFN-γ receptor ligand-binding chain...Full Text Available
On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.
We have obtained optically clear samples of LuAP:Ce from the Institute of Physical Research, Ashtarak, Armenia, measuring up to 5x5x40 mm{sup 3}. The photo electron yield for a number of theses samples was measured with a Philips XP2020Q photomultiplier tube, and 556 photo electrons per MeV was obtained for the best samples. This is comparable to what is obtained from BGO crystals under the same condition, but a factor of 5 less than what is obtained with an LSO sample of similar dimensions. The light in LuAP:Ce increases with cerium concentration between 0.13 and 0.47%.
A standard of "2"1"0Pb in solution was produced at the National Physical Laboratory by a novel technique combining Cerenkov counting with the established liquid scintillation efficiency tracing technique known as the CIEMAT/NIST method. Coincidence counting was applied in order to validate the measurements and the activity concentrations of the solution determined with each technique are shown to be in agreement. Radiochemical separation of the "2"1"0Pb from its daughters was also necessary and the scheme for the separation is described. After performing this two-stage standardisation, the uncertainty was successfully lowered to 0.66% (k=1). This uncertainty is approximately a factor of four lower than previously achieved at NPL by the classical method of standardisation of radionuclides, i.e. coincidence counting.
A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).
Environmental radon monitoring activities at the DOE Fernald Environmental Management Project (FEMP) have been conducted extensively since the early 1980`s. Monitoring has been conducted at ambient concentration levels (< 1 pCi/L Rn-222), inside buildings, and at significantly elevated levels (hundreds of thousands pCi/L Rn-222) within the K-65 silo that store concentrated radium bearing wastes. The purpose of this paper/presentation is to present and discuss some of the difficulties encountered/solutions (e.g. reliability, detection limits, affects of environmental factors, data transfer, etc.) that have been discovered while taking measurements using both alpha track-etch passive integrating detectors and alpha scintillation real-time detectors. A short summary and conclusion section is provided following each topic presented.
The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...
MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...
The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented challenges in the design and construction ...
A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.
Selenium 79 is a beta emitter produced from (235)U fission and is one of the long half-life radionuclides of interest in nuclear waste disposal problematic because of its potential migration capacity to the surface environment. Measurement of (79)Se is particularly difficult due to its low activity in waste matrices (about 10(-3)Bqg(-1)). A radiochemical procedure based on ion exchange separations was already described in a previous paper. This work presents different applications of the radiochemical separation to waste samples and an improvement of this procedure, including a selective extraction of selenium as diethylselenium in an organic solvent followed by a re-extraction in aqueous medium. This additional step allows the decontamination factor to be increased with the aim of counting (79)Se by liquid scintillation counting. PMID:19071740
The electronic structures of the set of molecular clusters of dielectric oxide crystals AWO4 (A = Pb, Cd, Zn), the sizes of which increase sequentially are ab-initio calculated by the Restricted Hartree-Fock (RHF) method. The results of calculations of molecular orbitals and energy dependences of partial densities of electronic states of different clusters are compared each to other and to experimental data. It is found that calculated electronic structures of the tungstate groups and cations which are surrounded in cluster by certain number of the nearest neighbor atoms of the crystals quite well represent the experimentally obtained value of the forbidden gap of corresponding AWO4 crystal. (authors)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at {gamma}{gamma} colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R{sub p}-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)
We review some interesting virtual effects from the minimal supersymmetric model (MSSM) at #gamma##gamma# colliders. We conclude that in the research respects, such as supersymmetric particle pair production, CP-violation and electroweak-like one-loop corrections in top quark pair production, the FCNC in the R_p-violating MSSM, linear collider (LC) operating in photon-photon collision mode provides powerful facilities in the measurements of new physics objects. For a precise and thorough study of the new physics, the investigation of the supersymmetric quantum effects is necessary. (author)
In view of the interest in the use of gamma irradiation to extend the storage life of pre-packaged foods a report is made on the effects of gamma radiation on the migration of Irganox 1076 and Irganox 1010, antioxidants present in food packaging plastics, into synthetic triglyceride fatty-food simulant HB307 and iso-octane. The extent of migration was assayed by h.p.l.c. techniques. Migration into HB307 and iso-octane decreased steadily as irradiation progressed suggesting that gamma irradiation of packaging materials helps to prevent the contamination of food by antioxidants in the packaging. (U.K.).
Some aspects of metrological provision of X-ray radiometric analyzers for mineral raw composition and gamma-gamma-logging equipment are considered. Standard samples (SS) based on the phenol-formaldehyde resin with the introduced quantities calculated of element compositions in the form of oxides and salts are described. Principles of metrological provision developed are used when carrying out state acceptance tests of X-ray radiometric analyzer RAL-M-102 ''Ehkran'' and gamma-gamma-logging equipmnt RSK-102. Economic benefit from introduction of an SS set is #approx# 60-100 thousand roubles per year.
We consider the impact of a 4th generation on Higgs to $\\gamma\\gamma$ and $WW,ZZ$ signals and demonstrate that the Tevatron and LHC have essentially eliminated the possibility of a 4th generation if the Higgs is SM-like and has mass below 200 GeV. We also show that the absence of enhanced Higgs signals in current data sets in the $\\gamma\\gamma$ and $WW,ZZ$ final states can strongly constrain (almost eliminate) the possibility of a 4th generation in two-Higgs-doublet models of type II (in the MSSM).
We have studied the signals for a heavy Higgs boson in the processes {gamma}{gamma}{yields}WWWW, and {gamma}{gamma}{yields}WWZZ at a photon linear collider. The results are based on the first complete tree-level calculation for these reactions. We show that, with a forward ``spectator`` W tag, and a central ``spectator`` W veto to suppress backgrounds from transverse W, Z production, the invariant mass spectrum of central WW, ZZ pairs is sensitive to Higgs bosons with a mass up to 1 TeV in a 2-TeV linear collider. ((orig.)).
The heavy Higgs bosons H,A of the minimal supersymmetric extension of the Standard Model can be produced as resonances in high-energy {gamma}{gamma} colliders. Prospects of the search for these particles in bb-bar and neutralino-pair final states are studied in this report. Heavy Higgs bosons can be found with masses up to about 70-80% of the initial e{sup +}e{sup -} collider energy for moderate values of tan {beta}, i.e. in areas of the parameter space not accessible at other colliders.
We study heavy physics effects on the Higgs production in {gamma}{gamma} fusion using the effective Lagrangian approach. We find that the effects coming from new physics may enhance the standard model predictions for the number of events expected in the final states {bar {ital b}}{ital b}, {ital WW}, and {ital ZZ} up to one order of magnitude, whereas the corresponding number of events for the final state {bar {ital t}}{ital t} may be enhanced up to two orders of magnitude. {copyright} {ital 1996 American Institute of Physics.}
We study heavy physics effects on the Higgs production in #gamma##gamma# fusion using the effective Lagrangian approach. We find that the effects coming from new physics may enhance the standard model predictions for the number of events expected in the final states bar bb, WW, and ZZ up to one order of magnitude, whereas the corresponding number of events for the final state bar tt may be enhanced up to two orders of magnitude. copyright 1996 American Institute of Physics.
The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).
Most general tbW couplings were investigated in the process {gamma}{gamma} {yields} tt-bar {yields} l{sup {+-}}X for unpolarized photon beams. The double angular and energy distribution of the lepton was calculated and an optimal-observable analysis on it was carried out for the SM tt-bar production mechanism. It was also shown that the leptonic angular distribution is insensitive to non-standard tbW vertex. That means that observation of non-standard effects indicates existence of some new physics in the production part.
Most general tbW couplings were investigated in the process #gamma##gamma# #-># tt-bar #-># l"#+-#X for unpolarized photon beams. The double angular and energy distribution of the lepton was calculated and an optimal-observable analysis on it was carried out for the SM tt-bar production mechanism. It was also shown that the leptonic angular distribution is insensitive to non-standard tbW vertex. That means that observation of non-standard effects indicates existence of some new physics in the production part.
Samples of vynil-benzene and vinyl acetate were irradiated with gamma rays from a sup(60)Co source. Viscosity analysis performed by using the method of Stokes showed an increase in the viscosity of the materials up to the total solidification for increased doses of gamma rays. This result characterized the formation of macromolecules of two thermal plastics, the poly (vinyl-benzene) and the poly (vinyl acetate). (author).
The results of photoneutron spectra measurements for the reaction (#gamma#,n) on the Sr-88 nuclei near threshold are presented. The parameters of resonance levels, as well as radiative S_#gamma#"("1") and neutron S_n"("1") strength functions for transitions on the first excited level of Sr-87 were obtained. 2 refs.; 1 fig.; 1 tab.
An investigation of the Ll x-#gamma# angular correlations following the decay of "2"0"7Bi is done by using a Si(Li) semiconductor counter as L x-ray detector. Coincidence measurements at five different angles were made between the 570-keV #gamma# ray (gated in the movable counter) and the Ll x spectrum (displayed in a multichannel analyzer).
The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.
The beams in electron linear colliders can be converted to nearly monochromatic photon beams by means of Compton backscattering of laser photons. The electron beams must then be diverted from the interaction point by some means, the best of which seems to be a plasma lens. This paper describes the constraints on the plasma lens in this application and shows how the ablation of solid hydrogen pellets might be able to produce plasmas to satisfy these constraints. ((orig.)).
It seems to be very natural that whole program for constructing and exploring of linear colliders (including photon colliders as the substantial part) should be divided by stages according to the increasing beam energy. We discuss the main stages of this program and the set of physical problems for each stage photon colliders. ((orig.))
It seems to be very natural that whole program for constructing and exploring of linear colliders (including photon colliders as the substantial part) should be divided by stages according to the increasing beam energy. We discuss the main stages of this program and the set of physical problems for each stage photon colliders. ((orig.)).
We discuss the main stages of a physical program for photon linear colliders. We consider the problems in electroweak theory, hadron physics, QCD, and nonlinear QED, as well as new particles and interactions, etc. The discussed stages constitute the parts of an entire ambitious program for linear colliders. ((orig.)).
E-beam and gamma products from the radiolysis of aqueous solutions of (+-)-metoprolol tartrate, saturated in nitrogen, are analyzed by HPLC with on-line mass and UV detectors. The structures of 10 radiolytic products common to e-beam and gamma irradiations are elucidated by comparing their fragmentation pattern to that of (+-)-metoprolol. Two of the radiolytic products are also metabolites. Different routes for the formation of the radiolytic products are proposed.
The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.
This paper presents the results obtained in the gamma scanning of two fuel pins from the bent subassembly of the fast breeder test reactor (FBTR) using a segmented gamma scanning system employing segment correlation developed for the assay of glove box solid waste. In addition to the actinide profiles, the paper also discusses the fission products and clad activation product profiles and tries to correlate the experimental values of the latter with computed values. (author). 4 refs., 1 fig., 1 tab.
The radiative decay K->mu nu gamma has been studied at ISTRA+ setup in a new kinematical region. About 46K events of K->mu nu gamma have been observed. The sign and value of Fv-Fa have been measured for the first time. The result is Fv-Fa=0.16(4)(5).
This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.
Effects of gamma irradiation on the physiological effectiveness of Korean medicinal herbs were investigated. The physiological effectiveness including antioxidant and anticomplement function, nitrite scavenging and electron donating ability of Korean medicinal herbs by gamma irradiation at 10 kGy did not differ from that of the nonirradiated control.
Effects of gamma irradiation on hygienic quality and extraction yields in twenty-one kinds of Korean medicinal herbs were investigated. Gamma irradiation at 5-10 kGy inactivated contaminating microorganisms. The total extraction yield in fifteen kinds of the investigated medicinal herbs increased by 5-25% by a dose of 10 kGy. (author)
The effect of irradiation using several doses of X- and #gamma#-rays (10, 20, 40, 60, 80 and 100 kGy), upon total phenolic compounds contained in the leaves of Maytenus aquifolium Martius (Celastraceae) 'espinheira santa', was investigated. The content of phenolic compounds (measured by the Folin-Denis spectrophotometric method) was unaffected by X- or #gamma#-ray irradiation, at any dose. (author)
The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting #gamma#-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision.
The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting {gamma}-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision. ((orig.)).
The crabbing of an incident photon beam from a laser, and the electron beam with which it interacts at the conversion point, is shown to have the same efficiency as in head-on Compton scattering, but with the advantages of a crossing geometry. The resulting #gamma#-ray beam is also crabbed, which allows for a crossing collision point, while maintaining the luminosity at the same value it would have in a head-on collision. ((orig.)).
In Pseudomonas paucimobilis UT26, gamma-hexachlorocyclohexane (gamma-HCH) is converted to 2,5-dichloro-2,5-cyclohexadiene-1,4-diol (2,5-DDOL), which is then metabolized to 2,5-dichlorohydroquinone....Full Text Available
The availability of rice, gamma -irradiated up to 4.6 x 10/sup 4/ and 3.5 x 10/sup 5/r for koji was studied. The enzyme activities of koji of the steamed samples were stronger than the unirradiated rice in amylase and protease. The sensory test on the once-steamed irradiated rice was almost the same as the twice-steamed unirradiated rice. (OID)
We compute the limiting distribution, as n approaches infinity, of the number of cycles of length between gamma n and delta n in a permutation of [n] chosen uniformly at random, for constants gamma, delta such that 1/(k+1) <= gamma < delta <= 1/k for some integer k. This distribution is supported on {0, 1, ... k} and has 0th, 1st, ..., kth moments equal to those of a Poisson distribution with parameter log (delta/gamma). For more general choices of gamma, delta we show that such a limiting distribution exists, which can be given explicitly in terms of certain integrals over intersections of hypercubes with half-spaces; these integrals are analytically intractable but a recurrence specifying them can be given. The results herein provide a basis of comparison for similar statistics on restricted classes of permutations.
The authors describe a new method which makes it possible to determine the radial distribution of the diffuse component of galactic gamma rays outside the solar circle. They use the observation that a good correlation exists between gamma-ray intensities and total column densities of the local interstellar gas and that the fractional column density of H_2<0.1 HI outside the solar circle. Thus the gamma-ray intensities are shown to be proportional to N(HI). The authors use the kinematics of the HI to determine the distances from which various fractions of the emission originate in the second and third galactic quadrants. Preliminary results of our analysis show that a significant flux of gamma rays originates from distances as large as 18 kpc from the galactic centre. (Auth.).
Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.
Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.
Compton backscattering of laser photons near the interaction point of an e{sup +}e{sup -} or e{sup -}e{sup -} collider can be used to produce a {gamma}-{gamma} or {gamma}-e{sup -} collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e{sup +}e{sup -} colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).
We construct the time-dependent radiation model for the pulsar wind nebulae (PWNe), assuming that leptons are accelerated in resonant scattering with heavy nuclei, which are injected into the nebula by the pulsar. The equilibrium spectra of these particles inside the nebula are calculated taking into account their radiation and adiabatic energy losses. The spectra of {gamma}-rays produced by these particles are compared with the observations of the PWNe emitting TeV {gamma}-rays and predictions are made for the expected {gamma}-ray fluxes from other PWNe. Expected neutrino fluxes and neutrino event rates in a 1 km{sup 2} neutrino detector from these nebulae are also calculated. It is concluded that only the Crab Nebula can produce a detectable neutrino event rate in the 1 km{sup 2} neutrino detector. Other PWNe can emit TeV {gamma}-rays on the level of a few percent of that observed from the Crab ...
There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper ...
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.
An easy and simple method for gamma assay of large multi gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following tow simple well known facts: Large and small samples of the same homogenous material have identical activities; the self attenuation of gamma line decreases as its energy increases. The method was successfully applied to NORM (Naturally Occurring Radioactive Material) large samples. This method doesn't require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed. (author)
{gamma}-Butyrolactone-based electrolytes have been used as the operating electrolytes for aluminum electrolytic capacitors. The chemical stability of these electrolytes at elevated temperatures has been examined by monitoring the decrease in their electrolytic conductivities. The deteriorated electrolytes were analyzed by gas and liquid chromatography and the conductivity decrease was directly correlated with the loss of acid components. In quaternary ammonium hydrogen maleate/{gamma}-butyrolactone electrolytes, the maleate anion decomposed by decarboxylation resulting in a complex polymer containing polyester and polyacrylate structures. Quaternary ammonium benzoate/{gamma}-butyrolactone electrolytes decomposed by SN2 reactions giving alkyl benzoates and trialkylamines. The deterioration of the carboxylate salt/{gamma}-butyrolactone electrolytes was accelerated by electrolysis. (orig.)
A complete code based on the finite element method (FEM) is used to study the attenuation of gamma rays, of source energy 9 MeV, in simple homogeneous lead and water systems. The results are compared, in tables and graphs, with those produced by a Monte Carlo method of solution. In the comparison, particular attention is paid to the annihilation gamma rays generated by the pair production process, to energy deposition, and to the leakage spectra. A model, multilayer, slab shield, having a fission neutron source impinging on the left-hand face, is also solved by the FEM code, using data from a coupled neutron/gamma ray cross section library. The resulting neutron and gamma ray flux distributions, and the leakage spectra, are shown graphically. (author).
The thiazolidinedione (TZD) or glitazone class of peroxisome proliferator-activated-#gamma# (PPAR-#gamma#) ligands not only induce adipocyte differentiation and increase insulin sensitivity, but also exert growth inhibitory effects on several carcinoma cell lines in vitro as well as in vivo. In the current study the in vitro effect of four PPAR-#gamma# agonists (ciglitazone, pioglitazone, troglitazone, rosiglitazone) on the cell growth of seven human neuroblastoma cell lines (Kelly, LAN-1, LAN-5, LS, IMR-32, SK-N-SH, SH-SY5Y) was investigated. Growth rates were assessed by a colorimetric XTT-based assay kit. Expression of PPAR-#gamma# protein was examined by immunohistochemistry and Western blot analysis. All glitazones inhibited in vitro growth and viability of the human neuroblastoma cell lines in a dose-dependent manner showing considerable effects only at high concentrations (10 #mu#M and 100 ...
We examine the virtual effects of Kaluza-Klein (KK) states on Higgs physics in universal extra dimension models. We study the partial widths {Lambda}{sub h{yields}gg}, {Lambda}{sub h{yields}{gamma}{gamma}}, and {Lambda}{sub h{yields}{gamma}Z}, which are relevant for Higgs production and detection in future collider experiments. These interactions occur at one loop in the Standard Model, as do the KK contributions. We find that the deviations induced by the KK exchanges can be significant; for one extra dimension, the gg {yields} h production rate is increased by 10% - 85% for the mass of the first KK state in the range 500 {approx}> m{sub 1} {approx}> 1500 GeV, a region untested by current direct search and precision measurement constraints. The h {yields} {gamma}{gamma} decay width is decreased by {approx}< 20% in the same mass range. For two or more universal extra dimensions the results are cutoff ...
2009 has been an extraordinary year for gamma-ray pulsar astronomy and 2010 promises to be equally good. Not only have we registered an extraordinary increase in the number of pulsars detected in gamma rays, but we have also witnessed the birth of new sub-families: first of all, the radio-quiet gamma pulsars and later an ever growing number of millisecond pulsars, a real surprise. We started with a sample of 7 gamma-ray emitting neutron stars (6 radio pulsars and Geminga) and now the Fermi-LAT harvest encompasses 24 "Geminga-like" new gamma-ray pulsars, a dozen millisecond pulsars and about thirty radio pulsars. Moreover, radio searches targeted to LAT unidentified sources yielded 18 new radio millisecond pulsars, several of which have been already detected also in gamma rays. Thus, currently the family of gamma-ray emitting neutron stars ...
In the decoupling limit M_A_"0"2>>M_Z"2, the heavy CP-even, CP-odd, and charged Higgs boson masses are nearly degenerate, sin(#beta#-#alpha#) approaches 1, and the lightest CP-even Higgs boson almost displays the same properties as the standard model Higgs boson. But the top and bottom squark sectors can change this pattern through radiative corrections. We find that there are parameter regions at small and moderate tan #beta# in the minimal supersymmetry standard model under experimental constraints of (g-2)_#mu#, b#->#s#gamma#, and lower bounds of Higgs boson and sparticle masses, where sin"2(#beta#-#alpha#) is damped (say below 0.8), which has a significant effect on Higgs couplings g_h_"0_V_V(V=W"#+-#,Z"0) and g_h_"0_#gamma#_#gamma#. We discuss its impact on the lightest CP-even Higgs boson production at #gamma##gamma# colliders.
Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for ...
A future e"-e"+ (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an #gamma#-#gamma# (gamma-gamma) or a e"--#gamma# collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e"-e"+ configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. They also address concerns ...
A future e{sup -}-e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup -}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup -}-e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5-15 kW from the laser which is beyond the current state of the art. In this paper, we address how to generate the required pulse format and how the high average power requirement can be met with conventional laser technology. We also address ...
A future e{sup {minus}}e{sup +} (electron-positron) linear collider can be configured with perhaps minimal modification to serve as an {gamma}-{gamma} (gamma-gamma) or a e{sup {minus}}-{gamma} collider. This is accomplished by Compton-backscattering low energy photons (from a laser source) off of the high-energy electron beams prior to the crossing of the electron beams. However, to be competitive with the e{sup {minus}}e{sup +} configuration, the luminosity cannot be compromised in the process. This requires that the laser source deliver a sufficient number of photons per pulse with a pulse format and rate matching that of the electron beams. As it turns out, this requires an average optical power of 5 to 15 kW from the laser which is beyond the current state of the art. In this paper, the authors address how to generate the required pulse format and how the high average power requirement can be met with conventional laser ...
The purpose of this study is to search for a new method of dispersing spilled heavy oil, which has a detrimental effect on the natural environment and marine ecosystem. A method ejecting a waterjet vertically downward to heavy oil on the water surface was studied, particularly focusing on the effect of the guide nozzle shape. The waterjet comprised heavy oil and minute air bubbles, and passed through the hole of the guide nozzle. Thirteen guide nozzle shapes were tested and compared. The dispersion efficiency of a tapered hole was the best among the 13 nozzles. The flow in the hole of the guide nozzles was recorded by a high-speed video camera. The occurrence of two flows, regular and counter flows, was observed in the taper guide nozzle. It seemed that the counter flows generated the shearing force between the waterjet and the heavy oil layer. It is considered that the shearing force determines the surplus efficiency of disperse.