WorldWideScience
1

Hybrid Camera Surveillance System Using Robust Human Detection  

Science.gov (United States)

We propose a novel surveillance system that uses hybrid camera network. The system contains a panorama camera and PTZ cameras to take the wide range images and face images at high enough resolution for identification tasks. The robust human detection methods include robust background subtraction method (RRC), skin color segmentation and face tracking method. First, the system detects persons from a panorama image, and then the detailed face images are obtained with the PTZ cameras. The PTZ cameras can track the faces using the four directional features and the relaxation matching. In addition, the system has automatic camera position calibration feature. Thus, the user can use the system without any troublesome settings.

2007-01-01

2

Study on dose distribution of therapeutic proton beams with prompt gamma measurement  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma ...

2007-03-15

3

Thyroidal uptake of iodine-123 in children using a gamma camera and computer  

Energy Technology Data Exchange (ETDEWEB)

The measurement of thyroidal uptake of radioiodine using a gamma camera and computer is described. In 12 children there was good agreement with simultaneous measurements using a probe, while in a further 14 patients the uptake values were consistent with the clinical diagnosis. The technique should be especially useful for infants and small children.

1985-10-01

4

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in ...

2000-03-01

5

Quantitative bone scintigraphy. A methodological evaluation in prostate cancer  

International Nuclear Information System (INIS)

Purpose: To evaluate a simple method for quantification of focal activity in bone scintigraphy (BS). Material and methods: The gamma camera was calibrated using a phantom. Quantitative bone scintigraphy (QBS) was performed on 11 men recently diagnosed with prostate cancer (PCa), for whom routine BS showed involvement of the skeleton. Following endocrine therapy for 4 to 8 months, a second QBS was performed. Changes in QBS values were then compared to changes in serum levels of prostate-specific antigen (PSA). Results: PSA response indicating regression of PCa was accompanied by a decrease in the QBS value in 8 of the 11 patients. The overall mean error of the QBS values was 15%. conclusion: QBS according to this method is a relatively simple procedure that might contribute to objective evaluation of therapeutic effects in skeletal metastases, although its validity must be tested in ...

2000-03-01

6

Search for TeV Counterparts in $\\gamma$-Ray Bursts  

CERN Document Server

Based on BACODINE network notification the Whipple Observatory gamma-ray telescope has been used to search for the delayed TeV counterpart to BATSE-detected gamma-ray bursts. In the fast slew mode, any point in the sky can be reached within two minutes of the burst notification. The search strategy, necessary because of the uncertainty in burst position and limited FOV of the camera, is described.

1997-01-01

7

Investigation of W"1"7"7 decay scheme by #gamma##gamma#-coincidence method  

International Nuclear Information System (INIS)

... coincidence spectrometry decay excited states gamma spectra half-life

1973-01-29

8

Laser monitoring of the size and polarization of the gamma beams of #gamma##gamma# and e#gamma# colliders  

International Nuclear Information System (INIS)

It is proposed to measure the spot sizes and polarization of #gamma# beams of future #gamma#e and #gamma##gamma# colliders detecting e"+e"- pairs produced as a result of interaction of high energy #gamma# quanta with density modulated and not modulated laser photons. The quantum electrodynamics cross sections, necessary numerical results as well as a short comparison of the proposed method with some other methods are given. (orig.).

9

Quantitative bone scintigraphy in patients with osteoporosis  

International Nuclear Information System (INIS)

Quantitative bone scans were evaluated in 16 patients with osteoporosis and in a control group of 7 healthy subjects. Along with a detailed biochemical analysis of calcium-phosphorus metabolism and standartized reongenographs, a quantitative dynamic bone scintigraphy was performed according to the method proposed by the authors. The bone-accumulating factor K_b was determined on the base of mathematical analysis of the graph reflecting activity changes in bone tissue unit during the investigation, the blood-elimination factor K_h and kidney-elimination factor K_k. In addition the accumulation index AI (in %) was calculated as a relation between the activity in bone tissue unit, registered in 20 min interval, and the activity in soft tissues for the same time. Whereas the static gamma camera scintigraphy, made 3-4 hrs after injecting of the osteotrope radiopharmaceuticals, showed no specific changes in the patients examined, ...

10

Quantitative bone scintigraphy and 24-hour whole-body counting of [sup 99m]Tc-methylene diphosphonate in patients with prostatic carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of [sup 99m]Tc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of ...

1992-10-01

11

Quantitative bone scintigraphy and 24-hour whole-body counting of "9"9"mTc-methylene diphosphonate in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Thirty-four patients with prostatic carcinoma were studied with quantitative bone scintigraphy and whole-body counting (WBC) 1 and 24 h after injection of "9"9"mTc-MDP before as well as two weeks and two months after orchiectomy. Thirteen of the patients had normal bone scintigrams and WBR at the three different investigations; 21 had skeletal metastases. The latter showed throughout the study higher local gamma camera count rates as well as WBR values than the patiens with normal scintigrams. In these patients a ''flare phenomenon'', with an increase in count rate two weeks after orchiectomy followed by a decrease two months post-operatively, was seen with quantitative bone scintigraphy but not with WBC. However, WBC may be a valuable method indicating the total extent of skeletal metastases in the body, while quantitative bone scintigraphy is more accurate in the interpretation of individual skeletal metastases. (orig.).

12

Imaging of dialysis-related amyloid (AB-amyloid) deposits with sup 131 I-beta 2-microglobulin  

Energy Technology Data Exchange (ETDEWEB)

The diagnosis of dialysis-related amyloid (AB-amyloid) has been based usually on clinical and radiological criteria. Following the discovery that beta 2-microglobulin was the major protein of this amyloid, we isolated and radiolabelled uremic plasma beta 2-microglobulin. After intravenous injection, gamma-camera images of selected joint areas were obtained from 42 patients who were on regular hemodialysis therapy. Positive scans involving the shoulder, hip, knee and carpal regions were found in 13 of 14 patients treated for more than 10 years and 10 of 16 patients treated for 5 to 10 years. Patients treated for less time had negative scans. Specificity was indicated by negative scans in non-amyloid inflammatory lesions in control hemodialysis patients. Up to 48-fold tracer enrichment was detected in excised AB-amyloid containing tissue as compared to amyloid-free tissue. These findings suggest that circulating radiolabelled beta 2-microglobulin is taken up by the ...

1990-12-01

13

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being revamped to begin work with the ...

2001-07-01

14

Principles of photon colliders  

Energy Technology Data Exchange (ETDEWEB)

Future linear colliders offer unique opportunities to study {gamma}{gamma}, {gamma}e interactions. Using the laser backscattering method one can obtain {gamma}{gamma}, {gamma}e colliding beams with energy and luminosity comparable to the electron-position luminosity or even higher. In this review physical principles of photon colliders are described and various problems, concerning the accelerator, laser, interaction region and luminosity are discussed. Some examples of physical processes are given. ((orig.)).

1995-02-01

15

Activation cross sections of deuteron-induced nuclear reactions on hafnium  

International Nuclear Information System (INIS)

Experimental excitation functions for deuteron-induced reactions up to 20 MeV on high purity natural hafnium were measured with the activation method using a stacked foil irradiation technique. Metallic hafnium foils with thickness of 10 #mu#m were stacked together with 50 #mu#m thick aluminium and 12 #mu#m thick titanium foils. The aluminium foils served as energy absorber while the titanium foils were used to monitor the energy and intensity of the bombarding deuteron beam. From a detailed remeasurement of the complete excitation function of the "n"a"tTi(d,x)"4"8V monitor reaction it was possible to adopt the proper incident energy and beam intensity by comparing the results with the recommended values. High resolution off-line gamma-ray spectrometry was applied to assess the activity of each foil. From the measured activity independent and/or cumulative elemental or isotopic cross section data for production of Ta, Hf and Lu radioisotopes by ...

2010-11-15

16

Phantom simulation device for scintillation cameras  

Energy Technology Data Exchange (ETDEWEB)

A phantom simulation imaging quality control device is described that effectively simulates one centimeter lesions, using steel ball bearings as gamma ray attenuators. The bearings are mounted in a synthetic resinous sheet in an orthogonal pattern. The phantom can provide uniformity, resolution, linearity, distortion and field size checks, all with a single exposure.

1981-08-25

17

Inguino-scrotal hernia detection in the early phase of a bone scan  

International Nuclear Information System (INIS)

A large inguino-scrotal hernia was detected in the early phase of a radionuclide bone scan performed for evaluation of a femoral neck fracture not visualized on plain x-rays. The patient was administered 1 GBq of Scrotal scintigraphy using "9"9"mTc-MDP and a regional three-phase bone scan of the pelvis, hips and proximal femora was obtained on the gamma camera. Copyright (1999) Blackwell Science Pty Ltd

1999-11-01

18

Measuring the beam polarizations and the luminosity at photon-photon colliders  

Energy Technology Data Exchange (ETDEWEB)

We present methods to measure the beam polarizations and the luminosity of [gamma][gamma] colliders at TeV energy scale. The beam polarizations of a [gamma][gamma] collider can easily be monitored by comparing the numbers of events of the processes [gamma][gamma] [yields] l[sup +]l[sup -] and [gamma][gamma] [yields] W[sup +] W[sup -], where l means e or [mu]. The luminosity of a [gamma][gamma] collider is also measurable by the event rate of W boson pair productions and the light lepton pair productions. (orig.)

1993-11-01

19

Preliminary Fabry Perot testing - 1986  

Science.gov (United States)

Fabry Perot interferometry is a method of determining instantaneous velocities of an object in motion. The interferometer system is composed of the Fabry Perot interferometer, a laser, an electronic streak camera, and several focusing lenses. The first tests discussed were done on exploding bridgewire devices. During these tests, several system parameters were changed. These changes did not seem to affect the data, which appeared to be consistent. The second tests performed focused on slapper-type devices. It was determined that sandblasted, vapor-deposited aluminum on the slapper material would be required to yield quality data. Streak camera failure prevented much data from being collected. An effort is being made to replace the current streak camera. After it is replaced, a Fabry Perot and velocity interferometry system for any reflector comparison will be made. The results will be published as the ...

1987-04-30

20

Gamma-absorption identification of substance  

International Nuclear Information System (INIS)

The possibility of gamma-absorption identification of the analyzed substance is considered. the basic provisions of the proposed method are concentrated on the example of carbohydrates and hydrocarbons. The above method is tested experimentally on polyethylenes and polystyrene

21

None - TDGLOBAL - NASA  

Science.gov (United States)

vibration Isolation system for the camera. ... to further define the response of the camera vibration isolation system. These ...

22

A radiant temperature numerical method for laser-plasma diagnostic using SXRSC with absorption method  

International Nuclear Information System (INIS)

An numerical method was developed for measuring radiant temperature using a set of absorption-foils coupled to soft x ray streak camera, SXRSC, in laser plasma experiments. An numerical code, SCC, was given. An x-ray intensity ratio vs temperature was calculated for Parylene, C_3H_6, Mylar and Aluminium. A suitable range of the measuring temperature was discussed to some absorber.

1990-01-01

24

The scintigraphy of the brain: development, methods and present consequence  

International Nuclear Information System (INIS)

Brain scintiscanning which was first carried out exclusively 'statical' and only with test substances of limited quality has been replaced nowadays by 'dynamical' camera-sequency-scintiscanning with technetium. This brought considerable progress not only for identifying but also for the differential diagnosis of cerebro-organic processes. Development, methods, and integration of brain scintiscanning in a diagnostical conception are described briefly. (orig.).

25

166Ho-HA evaluation as therapeutic agent for rheumatoid arthritis treatment  

International Nuclear Information System (INIS)

Aim: Rheumatoid arthritis is a limiting disease having, among its pathological features, the inflammation of synovial tissue with progressive and later destruction of the articulation. This leads to joint deformation and loss of its function, generating pain and reducing the mobility of the affected articulation. The aim was to evaluate "1"6"6Ho-Hydroxyapatite ("1"6"6 Ho-HA) as potential radiopharmaceutical for the symptomatic treatment of chronic and acute arthritis. Materials and Methods: Holmiun-166 was produced by irradiation of Ho_2O_3 at La Reina Research Reactor, Nuclear Chilean Energy Commission. Hydroxyapatite was in-house synthesized. Its labelling and quality controls follows the internationally accepted procedures. An antigen's arthritis was induced to eight New Zealand rabbits with the "1"6"6 Ho-HA radiochemical being administered thereafter in two dosage modalities (single and double). The compound therapeutic efficiency was evaluated based upon ...

2002-09-01

27

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

28

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

29

Albedo method applied to coupled neutron-gamma shielding radiations; Metodo do Albedo aplicado a blindagem de radiacoes neutron-gama acoplados  

Energy Technology Data Exchange (ETDEWEB)

The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)

2000-07-01

30

Albedo method applied to coupled neutron-gamma shielding radiations  

International Nuclear Information System (INIS)

The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)

2000-10-15

31

Research on Dynamic Neutron Radiography in HANARO  

Energy Technology Data Exchange (ETDEWEB)

Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a ...

2005-07-01

32

Research on Dynamic Neutron Radiography in HANARO  

International Nuclear Information System (INIS)

Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 frames/sec. Thus, RTNR is good for observing time-averaged phenomena and HSNR is good for observing instantaneous phenomena. DNR is a ...

2005-10-27

33

Laser ray-tracing method for optical testing.  

Science.gov (United States)

We have developed a novel laser ray-tracing method to measure aberrations in optical systems. It consists of delivering narrow laser pencils (by a laser scanner), recording the spots that are formed on the image plane (with a CCD camera), and computing the position of each centroid. This approach could be considered an experimental (approximate) implementation of standard numerical ray tracing. Several tests and experiments, including a direct comparison with a Hartmann-Shack wave-front sensor, provided highly satisfactory results that confirmed the validity of the method and revealed potential advantages. PMID:18073906

1999-07-15

34

The centers of early-type galaxies with HST; 2, empirical models and structural parameters  

CERN Document Server

We present a set of structural parameters for the central parts of 57 early-type galaxies observed with the Planetary Camera of the Hubble Space Telescope. These parameters are based on a new empirical law that successfully characterizes the centers of early type galaxies. This empirical law assumes that the surface brightness profile is a combination of two power laws with different slopes gamma and beta for the inner and outer regions. Conventional structural parameters such as core radius and central surface brightness are replaced by break radius r_b, where the transition between power-law slopes takes place, and surface brightness mu_b at that radius. An additional parameter alpha describes the sharpness of the break. The structural parameters are derived using a chi-squared minimization process applied to the mean surface brightness profiles. The resulting model profiles generally give very good agreement to the observed profiles out to ...

1996-01-01

35

Real-time neutron radiography at the Iea-R1 m nuclear research reactor  

International Nuclear Information System (INIS)

A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average value is 0:70 +- ...

2003-06-01

36

Intermediate mass Higgs study at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future {gamma}{gamma} colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future {gamma}{gamma} collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

37

Intermediate mass Higgs study at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the efficient technique to extract the signal of the intermediate mass Higgs boson from the backgrounds at future #gamma##gamma# colliders. For a clear Higgs detection, it is important to fit the original electron accelerator energy depending on the Higgs mass, to set the polarization of the photon beams and to apply the efficient b quark tagging method. we demonstrate the extraction of information of Higgs parameters and the new physics from the observable physical quantities. It is clearly shown that a future #gamma##gamma# collider will have a rich potential for study on the new physics, as well as the Higgs physics. (author).

1995-05-01

38

Study of #beta#"- decay of "1"0"1Mo and "1"0"1Tc nuclei  

International Nuclear Information System (INIS)

... radioisotopes coincidence methods energy-level transitions gamma radiation

1998-09-08

39

Measurement of #gamma#-ray emission probabilities for "1"0"1Mo  

International Nuclear Information System (INIS)

"1"0"1Mo is one of the key nuclides in diagnosing fission burn-up. However, it's difficult to measure its nuclear decay data due to its short half-life. Present study concerns in the measurements of #gamma#-ray emission probabilities, P_#gamma#, of "1"0"1Mo and "1"0"1Tc using the balance of scheme method and the entire process recording. The P_#gamma# of "1"0"1Mo by the entire process recording is about 5% lower than that by using the balance of scheme method. The P_#gamma# of "1"0"1Tc using the two methods agree each other very well. So, it seems the #gamma#-ray emission probabilities as well as measurement method still need study further for "1"0"1Mo. (authors)

2006-07-01

40

Quantification of "2"3"5U and "2"3"8U activity concentrations for undeclared nuclear materials by a digital gamma-gamma coincidence spectroscopy  

International Nuclear Information System (INIS)

The purpose of this study is to investigate the possibility of verifying depleted uranium (DU), natural uranium (NU), low enriched uranium (LEU) and high enriched uranium (HEU) by a developed digital gamma-gamma coincidence spectroscopy. The spectroscopy consists of two NaI(Tl) scintillators and XIA LLC Digital Gamma Finder (DGF)/Pixie-4 software and card package. The results demonstrate that the spectroscopy provides an effective method of "2"3"5U and "2"3"8U quantification based on the count rate of their gamma-gamma coincidence counting signatures. The main advantages of this approach over the conventional gamma spectrometry include the facts of low background continuum near coincident signatures of "2"3"5U and "2"3"8U, less interference from other radionuclides by the gamma-gamma coincidence counting, and region-of-interest (ROI) imagine analysis for uranium ...

2011-06-01

41

Gamma heating in LMFBR media  

International Nuclear Information System (INIS)

State-of-the-art approaches for the calculation of gamma heating in LMFBR core, blanket and reflector regions have been evaluated, with particular emphasis on coupled neutron-gamma methods/cross section sets. The major source of calculational error was found to be the apparent failure to impose a mass-energy balance on total gamma energy yield from neutron capture and other interactions in the preparation of representative neutron-gamma cross section sets. The applicability of many simplifying assumptions was demonstrated, including: volume-weighted homogenization, insensitivity to the shape of the gamma-source-spectrum, gamma energy deposition equal to gamma energy source more than 10 cm inside large zones of uniform composition, and the negligible effect of bremsstrahlung. A simple one-group method ...

1976-01-01

42

Evaluation of surgical gamma probes for sentinel node localisation in cervical and vulvar cancer  

International Nuclear Information System (INIS)

Sentinel node (SN) scintigraphy for cervical and vulvar cancer guides the gynaecological oncologist in finding the metastatic lymph nodes during lymphadenectomy. The role of the surgical gamma probe in the sentinel node concept in gynaecological oncology is to localise (SN) both intra-operatively and transcutaneously. Intra-operative hand-held collimated gamma probes are increasingly used for detection of the sentinel lymph node. A comparative evaluation of handheld gamma probes: Neoprobe 1500, Europrobe, Gamma Finder, Gamma Ray Prospector GRP1 and GPR2 was performed using different detection methods. Laboratory tests were performed in which sensitivity, spatial resolution and angular sensitivity were evaluated. The results for each gamma probe were summarised and discussed. Awareness of a gamma probes capabilities and ...

43

Numerical simulation and experiment research of radiation performance in a dish solar collector system  

British Library Electronic Table of Contents (United Kingdom)

The Monte Carlo ray-tracing method is applied and coupled with optical properties to predict the radiation performance of solar concentrator/cavity receiver systems. Several different cavity geometries are compared on the radiation performance. A flux density distribution measurement system for dish parabolic concentrators is developed. The contours of the flux distribution for target placements at different distances from the dish vertex of a solar concentrator are taken by using an indirect method with a Lambert and a charge coupled device (CCD) camera. Further, the measured flux distributions are compared with a Monte Carlo-predicted distribution. The results can be a valuable reference for the design and assemblage of the solar collector system.

2010-01-01

44

Nuclear fuel assembly identification using computer vision  

Science.gov (United States)

This report describes an improved method of remotely identifying irradiated nuclear fuel assemblies. The method uses existing in-cell TV cameras to input an image of the notch-coded top of the fuel assemblies into a computer vision system, which then produces the identifying number for that assembly. This system replaces systems that use either a mechanical mechanism to feel the notches or use human operators to locate notches visually. The system was developed for identifying fuel assemblies from the Fast Flux Test Facility (FFTF) and the Clinch River Breeder Reactor, but could be used for other reactor assembly identification, as appropriate.

1985-11-01

45

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

46

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

47

A novel application of the multi-group method: Coupled neutron-gamma-electron cross-section library  

Energy Technology Data Exchange (ETDEWEB)

A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.

2006-02-15

48

A novel application of the multi-group method: Coupled neutron-gamma-electron cross-section library  

International Nuclear Information System (INIS)

A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.

2006-02-01

49

Grate monitoring systems, state of the art; Metoder foer rosteroevervakning, dagslaegesbestaemning  

Energy Technology Data Exchange (ETDEWEB)

During a number of years research and development projects have been made to present methods of monitoring the grate in a grate fired boiler. The monitoring is interesting in order to be able to increase efficiency, increase burn-out of ash, improve the status of emissions, improve transportation of ash and fuel through the furnace, reduce costs for operation and maintenance, handle greater loads etc. Improvement of the combustion has been concentrated to the development of the gas phase combustion. In the past few years the computer development has progressed rapidly and the use of optical monitoring methods have been made possible for monitoring grates. To analyse state of the art of optical grate monitoring systems three different methods have been used, literature search, inquiry where plant owners were asked if they have used grate monitoring systems and if so what experiences they have, and interviews with scientists ...

2001-01-01

50

Implementation of the Random Forest method for the Imaging Atmospheric Cherenkov Telescope MAGIC  

Energy Technology Data Exchange (ETDEWEB)

The paper describes an application of the tree classification method Random Forest (RF), as used in the analysis of data from the ground-based gamma telescope MAGIC. In such telescopes, cosmic gamma-rays are observed and have to be discriminated against a dominating background of hadronic cosmic-ray particles. We describe the application of RF for this gamma/hadron separation. The RF method often shows superior performance in comparison with traditional semi-empirical techniques. Critical issues of the method and its implementation are discussed. An application of the RF method for estimation of a continuous parameter from related variables, rather than discrete classes, is also discussed.

2008-04-11

51

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

52

Correction factors determination in large samples gamma assay using its own multi-gamma lines spectrum  

Energy Technology Data Exchange (ETDEWEB)

An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.

2009-10-15

53

Correction factors determination in large samples gamma assay using its own multi-gamma lines spectrum  

International Nuclear Information System (INIS)

An easy and simple method for gamma assay of large multi-gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following two simple well known facts: large and small samples of the same homogenous material have identical specific activities; the self-attenuation of gamma line decreases as its energy increases. The method was successfully applied to naturally occurring radioactive material (NORM) large samples. This method does not require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed.

2009-10-01

54

Correction factors determination in large samples gamma assay using its own multi gamma lines spectrum  

International Nuclear Information System (INIS)

An easy and simple method for gamma assay of large multi gamma lines samples was introduced in this work. This method performs the assay using point source calibration. The correction factors for volume and self-attenuation are experimentally deduced from the spectra of different thicknesses samples utilizing the following tow simple well known facts: Large and small samples of the same homogenous material have identical activities; the self attenuation of gamma line decreases as its energy increases. The method was successfully applied to NORM (Naturally Occurring Radioactive Material) large samples. This method doesn't require complicated mathematical procedures. Neither sample matrix data nor detector unit composition is needed. (author)

55

Detection of Second-Layer Corrosion in Aging Aircraft  

International Nuclear Information System (INIS)

The Compton backscatter technique has been applied to lap-joint in aircraft structure in order to determine mass loss due to exfoliative corrosion of the aluminum alloy sheet skin. The mass loss of each layer has been estimated from Compton backscatter A-scan including the aluminum sheet, the corrosion layer, and the sealant. A Compton backscattering imaging system has been also developed to obtain a cross-sectional profile of corroded lap-splices of aging aircraft using a specially designed slit-type camera. The camera is to focus on a small scattering volume inside the material from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the layered structure is scanned by moving the scattering volume through the thickness direction of the specimen. The theoretical model of the Compton scattering based on Boltzmann transport theory is presented ...

2009-12-01

57

New radioisotope for lung ventilation studies: 19-neon  

Energy Technology Data Exchange (ETDEWEB)

Neon 19, a 17-second positron-emitting radioelement, is produced continously by 23 MeV alpha particle bombardment of oxygen. For a 12 ..mu..A particle current the method of preparation described delivers 14 mCi of neon 19 per min to the functional exploration room. The radiochemically pure radioactive gas is diluted in air and breathed continously by the patient lying under a positron tomographic camera. The regional lung ventilation distribution is obtained on 2 cm thick sections of organ with a transverse resolution of 17 mm. Quantification of the ventilation output per unit lung volume is contemplated.

1980-10-01

58

Detection of the heavy Higgs boson at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We consider the possibility of detecting a heavy Higgs boson (m_H>2m_Z) in proposed #gamma##gamma# colliders through the semileptonic mode #gamma##gamma##->#H#->#ZZ#->#q bar ql"+l-. We show that due to the nonmonochromatic nature of the photon beams produced by the laser-backscattering method, the resultant cross section for Higgs production is much smaller than the on-resonance cross section, and generally decreases with increasing collider energy. Although continuum ZZ production is expected to be negligible, we demonstrate the presence of, and calculate sizable backgrounds from, #gamma##gamma##->#l"+l-Z,q bar qZ, with Z#->#q bar q,l"+l-, respectively, and #gamma##gamma##->#t bar t#->#b bar bl"+l-#nu# bar #nu#. This channel may be used to detect a Higgs boson of mass m_H up to around 350 GeV at a 0.5 TeV e"+e- collider, assuming a nominal yearly luminosity ...

59

Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging  

Energy Technology Data Exchange (ETDEWEB)

{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space ...

2006-01-15

60

New approach for in vivo detection of insulitis in type I diabetes: activated lymphocyte targeting with "1"2"3I-labelled interleukin 2  

International Nuclear Information System (INIS)

Insulitis is considered the histopathological hallmark of type I diabetes. In the non-obese diabetic (NOD) mouse, diabetes has never been observed in the absence of insulitis. The in vivo detection of insulitis could be of relevance for early prediction of diabetes. As approximately 15% of islet-infiltrating lymphocytes express interleukin 2 receptors, the authors have labelled recombinant inter-leukin 2 with "1"2"3I and used this radiopharmaceutical to detect insulitis by gamma camera imaging. The authors studied 71 prediabetic NOD and 27 normal Balb/c mice. Labelled #alpha#-lactalbumin was used as the control protein. In the first set of experiments the tissue distribution of radiolabelled interleukin 2 in isolated organs from animals sacrificed at different time points was studied. Higher radioactivity was detected in the pancreas of NOD mice injected with labelled interleukin 2, as compared to NOD mice receiving labelled ...

1994-01-01

61

Application of remote sensing and geophysics to the detection and monitoring of acid mine drainage  

Energy Technology Data Exchange (ETDEWEB)

The results of a study on the application of remote sensing and geophysical methods for the detection and monitoring of acid mine drainage (AMD) are summarized, with emphasis on those that appear most suitable. The study consisted of a literature review, an information survey of users and suppliers, and discussions with various experts. Space-borne sensors, airborne sensors, airborne videography and digital frame cameras, spectroradiometers, radar, and photographic data are considered. Geophysical methods are effective for measurement of sulphides, areas of active chemical oxidation, acid mine drainage, and contaminated ground water movement. The popularity and effectiveness of various geophysical methods are rated for AMD applications. 25 refs., 1 fig., 3 tabs.

1995-06-01

62

Neutron radiography with the cyclotron, 4  

International Nuclear Information System (INIS)

A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented together with some actual application to ...

1986-01-01

63

Gamma absorption determination of concentration in a three-component mixture  

International Nuclear Information System (INIS)

A method for the analysis of three-component mixtures is described. The method is used for contact-free determination of component concentration in the mixtures transported via a product duct. Formulae as an aid in choosing the gamma radiation source and estimating the efficiency of measurement are given. The errors of measurement by the method of formaline-water-carbamide mixture is 1-2 %. 9 refs.; 1 fig.

64

Use of gamma radiation for thermoplastics synthesis  

International Nuclear Information System (INIS)

Samples of vynil-benzene and vinyl acetate were irradiated with gamma rays from a sup(60)Co source. Viscosity analysis performed by using the method of Stokes showed an increase in the viscosity of the materials up to the total solidification for increased doses of gamma rays. This result characterized the formation of macromolecules of two thermal plastics, the poly (vinyl-benzene) and the poly (vinyl acetate). (author).

1991-05-27

65

Radiation damage on amorphous metals. [Helium ion, neutron and gamma ray irradiation  

Energy Technology Data Exchange (ETDEWEB)

The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.

1982-04-01

66

Environmental #gamma# dose rate monitoring system around Guangdong Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

This article introduces the composition, monitoring methods and working principles of environmental #gamma# dose rate continuous monitoring system at Guangdong Daya Bay Nuclear Power Station. The #gamma# dose rate monitoring status after modification of measurement conditions is introduced too.

67

Effect of X- and gamma-rays on phenolic compounds from Maytenus aquifolium Martius  

International Nuclear Information System (INIS)

The effect of irradiation using several doses of X- and #gamma#-rays (10, 20, 40, 60, 80 and 100 kGy), upon total phenolic compounds contained in the leaves of Maytenus aquifolium Martius (Celastraceae) 'espinheira santa', was investigated. The content of phenolic compounds (measured by the Folin-Denis spectrophotometric method) was unaffected by X- or #gamma#-ray irradiation, at any dose. (author)

2005-06-01

68

Production of scalar Higgs and pseudoscalar Higgs in multi-Higgs doublet models at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process {gamma}{gamma}{yields}tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future {gamma}{gamma} colliders for small values of tan {beta}. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)

2000-05-01

69

Production of scalar Higgs and pseudoscalar Higgs in multi-Higgs doublet models at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We present the effects of heavy CP-even (H) and CP-odd (A) Higgs bosons on the production cross section of the process #gamma##gamma##->#tt at the energy around the mass poles of the Higgs bosons. It is found that interference between H and A with small mass gap, as well as the ones between Higgs bosons and continuum, contributes to the cross section, if the photon beams are polarized and if we observe the helicity of the top quarks. It is demonstrated in the framework of the minimal supersymmetric extension of the standard model that the H and A contributions can be sizable at future #gamma##gamma# colliders for small values of tan #beta#. The methods to measure the CP-parity of the Higgs boson are also presented. The statistical significance of detecting the Higgs signals and measuring the Higgs CP-parity is evaluated. (orig.)

2000-05-01

70

GAVA: Spectral Simulation for In Vivo MRS Applications  

UK PubMed Central (United Kingdom)

An application that provides a flexible and easy to use interface to the GAMMA spectral simulation package is described that is targeted at investigations using in vivo MR spectroscopic methods....Full Text Available

2007-04-01

72

Four-fermion production at {gamma}{gamma} colliders: 2. Radiative corrections in double-pole approximation  

Energy Technology Data Exchange (ETDEWEB)

The O({alpha}) electroweak radiative corrections to {gamma}{gamma}{yields}WW{yields}4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for {gamma}{gamma}{yields}4f+{gamma}. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer {gamma}{gamma} - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs ...

2005-09-01

73

Four-fermion production at #gamma##gamma# colliders: 2. Radiative corrections in double-pole approximation  

International Nuclear Information System (INIS)

The O(#alpha#) electroweak radiative corrections to #gamma##gamma##->#WW#->#4f within the electroweak standard model are calculated in double-pole approximation (DPA). Virtual corrections are treated in DPA, leading to a classification into factorizable and non-factorizable contributions, and real-photonic corrections are based on complete lowest-order matrix elements for #gamma##gamma##->#4f+#gamma#. Soft and collinear singularities appearing in the virtual and real corrections are combined alternatively in two different ways, namely by using the dipole subtraction method or by applying phase-space slicing. The radiative corrections are implemented in a Monte Carlo generator called Coffer #gamma##gamma# - the computer code can be obtained from the authors upon request - which optionally includes anomalous triple and quartic gauge-boson couplings in addition and performs a ...

2005-09-01

74

A finite element study of gamma ray transport  

Energy Technology Data Exchange (ETDEWEB)

A complete code based on the finite element method (FEM) is used to study the attenuation of gamma rays, of source energy 9 MeV, in simple homogeneous lead and water systems. The results are compared, in tables and graphs, with those produced by a Monte Carlo method of solution. In the comparison, particular attention is paid to the annihilation gamma rays generated by the pair production process, to energy deposition, and to the leakage spectra. A model, multilayer, slab shield, having a fission neutron source impinging on the left-hand face, is also solved by the FEM code, using data from a coupled neutron/gamma ray cross section library. The resulting neutron and gamma ray flux distributions, and the leakage spectra, are shown graphically. (author).

1990-01-01

75

In-beam spectroscopy of nuclei  

International Nuclear Information System (INIS)

The main features and advantages of a new low energy nuclear spectroscopic method, the in-beam spectroscopy are described. Results of in-beam spectroscopic experiments performed at the Institute of Nuclear Research (ATOMKI, Debrecen, Hungary) are summarized. Gamma spectra of in-beam produced odd-odd nuclei were measured, gamma-energies were determined. Measurement of gamma-gamma coincidences led to the construction of energy level schemes of the investigated nuclei. Internal conversion electron spectroscopy was used to determine the multipolarities of transitions. A few spectra and level schemes are presented to illustrate the review. Theoretical interpretation of experimental results are briefly summarized. (D.Gy.).

1982-01-01

76

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic changes in canine livers. ...

1989-08-15

77

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method; Analise das radiacoes neutron e gama acopladas, aplicada a blindagem com varias camadas pelo metodo multigrupo do albedo  

Energy Technology Data Exchange (ETDEWEB)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The ...

2002-07-01

78

Analysis of coupled neutron-gamma radiations, applied to shieldings in multigroup albedo method  

International Nuclear Information System (INIS)

The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The ...

2002-01-01

79

Development of ARIES Baker-Nunn camera to a wide-field Imaging Telescope with CCD  

CERN Document Server

ARIES Baker-Nunn Schmidt telescope project is converting a Baker-Nunn satellite tracking camera for Astronomical research. Original Baker-Nunn camera produces an extremely large (5X30 degree) curved focal plane at the prime focus for photographic imaging. We present here the re-designing of the camera produces a wide (4 X 4 degree) flat field of view for CCD imaging observations, which have many scientific potentials in Astronomy. Imaging performance of the CCD camera is also estimated.

2009-01-01

83

Methods for proving the equivalency of detonator performance  

Energy Technology Data Exchange (ETDEWEB)

One of the challenges facing engineers is developing newer, safer detonators that are equivalent to devices currently in use. There is no clear consensus on an exact method for drawing equivalence of detonators. This paper summarizes our current efforts to develop diagnostics addressing various aspects of detonator design to better quantify and prove equivalency. We consider various optical techniques to quantify the output pressure and output wave shape. The development of a unique interpretation of streak camera breakouts, known as the apparent center of initiation, will be discussed as a metric for detonation wave shape. Specific examples apply these techniques to the comparison of a new laser-driven detonator with an existing exploding bridgewire (EBW) detonator. Successes and short-comings of the techniques will be discussed.

2009-01-01

84

Measurement of dynamic fracture toughness and failure behavior for explosive mock materials  

British Library Electronic Table of Contents (United Kingdom)

In this work, a pre-cracked semi-circular shaped explosive simulant was loaded using a split Hopkinson pressure bar (SHPB). A high-speed camera was used to capture the deformation and fracture process of the specimen in situ. The digital images were processed using the digital image correlation (DIC) method. Next, full displacement and strain fields were obtained. The displacement vector field shows that the specimen fractured under tensile stress action. The strain field can be used to predict the crack propagation. Results show that the method of combined DIC and SHPB is effective to study the dynamic deformation and fracture behavior of explosive simulants. In addition, the specimen was loaded using a drop weight. The fracture toughness of the specimen was preliminary measured.

2011-01-01

85

Dispersion of Spilled Heavy Oil by Impinging Waterjet  

Science.gov (United States)

The purpose of this study is to search for a new method of dispersing spilled heavy oil, which has a detrimental effect on the natural environment and marine ecosystem. A method ejecting a waterjet vertically downward to heavy oil on the water surface was studied, particularly focusing on the effect of the guide nozzle shape. The waterjet comprised heavy oil and minute air bubbles, and passed through the hole of the guide nozzle. Thirteen guide nozzle shapes were tested and compared. The dispersion efficiency of a tapered hole was the best among the 13 nozzles. The flow in the hole of the guide nozzles was recorded by a high-speed video camera. The occurrence of two flows, regular and counter flows, was observed in the taper guide nozzle. It seemed that the counter flows generated the shearing force between the waterjet and the heavy oil layer. It is considered that the shearing force determines the surplus efficiency of ...

2009-01-01

86

Non-destructive testing of refractories, especially AZS materials, with ultrasound, microwaves and {gamma}-radiation  

Energy Technology Data Exchange (ETDEWEB)

In principle four different methods (ultrasound, microwaves, {gamma}-radiation and x-rays) are available for the non-destructive testing of refractories. Three of these methods, i.e. ultrasound, microwaves and {gamma}-radiation, are in use by different producers of AZS materials to carry out the quality control of their products. This paper will compare the three methods on the basis of the physical properties, present the existing devices, and show the advantages as well as the limits of the different methods. {gamma}-radiography, the oldest method in use, has one main disadvantage, which is the requirement of protection against radioactive radiation. Furthermore, while cracks and cavities can be detected with this method, structural changes can not be monitored. Therefore, the ultrasonic ...

1995-08-01

87

The optimization of gamma spectra processing in prompt gamma neutron activation analysis (PGNAA)  

International Nuclear Information System (INIS)

The uncertainty of the elemental analysis is one of the major factors governing the utility of on-line Prompt Gamma Neutron Activation Analysis (PGNAA) in the blending and sorting of bulk materials. In this paper, a general method applicable to Gamma spectra processing is presented and applied to PGNAA in mineral industry. Based on the Fourier transform of spectra and their de-correlation in the Fourier space (the improvement of the conditioning of the correlation matrix), processing of overlapping of characteristic peaks minimizes the propagation of random errors, which optimizes the accuracy and decreases the detection limits of elemental analyses. In comparison with classical methods based on the linear combinations of relevant regions of spectra the improvement may be considerable, especially when several elements are interfering. The method is applied to four case stories ...

2009-04-15

88

Positron wave function in ReO_3 by the APW method  

International Nuclear Information System (INIS)

The wavefunction of a positron in ReO is calculated using the augmented-plane-wave method. Due to the loosely-packed structure of ReO_3, the ground-state GAMMA_1 wavefunction exhibits a marked anisotropy particularly around the oxygen ions, and a large fraction of a positron is distributed in the interstitial region. Experimental results of the positron annihilation 2#gamma#-correlations and the positron annihilation rates in ReO_3 are discussed based on the positron wavefunction. (orig.).

89

Estimation of gamma-absorption method for measurement of layers thickness in multi-layers articles  

International Nuclear Information System (INIS)

Certain problems of gamma-absorption method of measuring the thickness of layers in multi-layer items are analyzed. Two examples of solving the above-mentioned problems have been considered. One of them deals with a two-layer item, its integral thickness being known or measured in advance, the second example is referred to a two-layer item with unknown integral value

90

On the radial distribution of gamma rays in the outer galaxy  

International Nuclear Information System (INIS)

The authors describe a new method which makes it possible to determine the radial distribution of the diffuse component of galactic gamma rays outside the solar circle. They use the observation that a good correlation exists between gamma-ray intensities and total column densities of the local interstellar gas and that the fractional column density of H_2<0.1 HI outside the solar circle. Thus the gamma-ray intensities are shown to be proportional to N(HI). The authors use the kinematics of the HI to determine the distances from which various fractions of the emission originate in the second and third galactic quadrants. Preliminary results of our analysis show that a significant flux of gamma rays originates from distances as large as 18 kpc from the galactic centre. (Auth.).

1982-08-04

92

The uterine blush. A potential false-positive in Meckel's scan interpretation  

Energy Technology Data Exchange (ETDEWEB)

To determine the presence, prevalence, and clinical importance of /sup 99m/Tc pertechnetate uterine uptake, this retrospective analysis of 71 Meckel's scans was undertaken. Specifically, each study was evaluated for the presence of a focal accumulation of radiotracer cephalad to the bladder. Patients received an intravenous dose of 150 microCi/kg of /sup 99m/Tc pertechnetate. Each study consisted of 15 one minute anterior serial gamma camera images, and a 15, 30, and 60 minute anterior, right lateral and posterior scintiscan. Menstrual histories were obtained from all patients except two. No males (33/33), nor premenstrual (13/13), menopausal (4/4) or posthysterectomy (2/2) patients revealed a uterine blush. Eleven of 15 patients (73%) with regular menses demonstrated a uterine blush. They were in the menstrual or secretory phases of their cycle. Four demonstrated no uterine uptake, had regular periods, but were in the proliferative ...

1982-10-01

93

Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of [sup 99m]Tc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain ...

1993-10-01

94

Quantitative bone scintigraphy in prostatic carcinoma - long-term response to treatment  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed in 24 patients with prostatic carcinoma before orchiectomy and up to one to four years after operation. The gamma camera count rate was recorded over the lower thoracic and all lumbar vertebrae 4 h after injection of "9"9"mTc-MDP. Twelve patients has normal bone scintigrams throughout the study. They showed from two years after operation a slight increase in count rate values compared with the preoperative values, probability due to hormonal changes after orchiectomy and to age-related alterations in skeletal metabolism. Twelve patients had abnormal bone scintigrams. They showed as a response to treatment the flare phenomenon with an increase in count rate over the abnormal vertebrae when measured two weeks after operation followed by a decrease after two months. The lowest count rate values were obtained between six months and one year after operation. Thereafter the count rate seemed to remain on ...

95

Quantitative assessment of bone scintigraphy in the hip joint disease  

International Nuclear Information System (INIS)

Quantitative assessment of bone scintigraphy was performed in fifty-six patients with hip joint disease including femoral neck fracture, aseptic necrosis of the femoral head, traumatic dislocation of the hip, Perthes disease, and transient synovitis of the hip. In the static study, bone scintigraphy was obtained 3 hours after injection of sup(99m)Tc-MDP by gamma camera equipped with a computer and uptake ratios were calculated. In the dynamic study, bone scintigraphy was performed in one, 3 and 5 hours after injection of radionuclide. Femoral head uptake ratio was markedly decreased in osteonecrosis following femoral neck fracture and characteristically increased in aseptic necrosis of the femoral head but prolonged retention of sup(99m)Tc-MDP could be observed. Uptake ratios of epiphysis were decreased in Perthes disease but normal in transient synovitis of the hip. Static and dynamic study of bone scintigraphy may be useful for early ...

96

Bone scintigraphy in fluoride treated osteoporosis  

Energy Technology Data Exchange (ETDEWEB)

Quantitative bone scintigraphy was performed on 23 white females with post-menopausal osteoporosis and vertebral compression fractures. These patients were then entered into a randomized, double-blind clinical trial or sodium fluoride therapy (NaF=14, placebo=9) which included repeat bone scintigraphy every six months. Scintigraphic images were acquired for 500K counts per image over the total body with computer acquisition over the posterior thoracic and lumbar spine. Images were obtained on a wide field-of-view gamma camera two hours after injecting 15 mCi of Tc-99m MDP. Data analysis showed a significant reduction in the activity ratio of abnormal vertebral body to normal vertebral body in those patients treated with sodium fluoride (paired t-test p=0.0095). No significant change was observed in the control group of (p=0.142). These results suggest that sodium fluoride therapy promotes more rapid healing of osteoporotic vertebral fractures. ...

1985-05-01

97

Ozone production process in pulsed positive dielectric barrier discharge  

International Nuclear Information System (INIS)

The ozone production process in a pulsed positive dielectric barrier discharge (DBD) is studied by measuring the spatial distribution of ozone density using a two-dimensional laser absorption method. DBD occurs in a 6 mm point-to-plane gap with a 1 mm-thick glass plate placed on the plane electrode. First, the propagation of DBD is observed using a short-gated ICCD camera. It is shown that DBD develops in three phases: primary streamer, secondary streamer and surface discharge phases. Next, the spatial distribution of ozone density is measured. It is shown that ozone is mostly produced in the secondary streamer and surface discharge, while only a small amount of ozone is produced in the primary streamer. The rate coefficient of the ozone production reaction, O + O_2 + M #-># O_3 + M, is estimated to be 2.5 x 10"-"3"4 cm"6 s"-"1.

2007-01-07

98

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

99

LDL (Landscape Digital Library) a Digital Photographic Database of a Case Study Area in the River Po Valley, Northern Italy  

CERN Document Server

Landscapes are both a synthesis and an expression of national, regional and local cultural heritages. It is therefore very important to develop techniques aimed at cataloguing and archiving their forms. This paper discusses the LDL (Landscape Digital Library) project, a Web accessible database that can present the landscapes of a territory with documentary evidence in a new format and from a new perspective. The method was tested in a case study area of the river Po valley (Northern Italy). The LDL is based on a collection of photographs taken following a systematic grid of survey points identified through topographic cartography; the camera level is that of the human eye. This methodology leads to an innovative landscape archive that differs from surveys carried out through aerial photographs or campaigns aimed at selecting "relevant" points of interest. Further developments and possible uses of the LDL are also discussed.

2001-01-01

100

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

Energy Technology Data Exchange (ETDEWEB)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics ...

1994-08-01

101

Development of the high sensitivity real-time neutron radiography for low-flux neutron sources  

International Nuclear Information System (INIS)

The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was estimated to be almost 100%. For the purpose of developing a system with higher sensitivity, consideration of neutron statistics ...

1994-01-01

102

Crack tip opening angle measurement through a girth weld in an X100 steel pipeline section  

British Library Electronic Table of Contents (United Kingdom)

ABSTRACT Crack tip opening angle (CTOA) is becoming one of the most accepted methods for characterizing fully plastic fracture. It provides a measure of the resistance to fracture for a material in cases where there is a large degree of stable-tearing crack extension during the fracture process. Our current pipeline research uses the CTOA test as an alternative, or addition, to the CTOD (crack tip opening displacement) and the fracture energy characterization provided by the J-integral approach. A test technique was developed for measurement of CTOA that uses a modified double cantilever beam (MDCB) specimen. A digital camera and image analysis software were used to record the progression of the crack tip and to estimate the CTOA. In this article, CTOA data on crack growth orientations per...

2008-01-01

103

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

104

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

105

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture  

Energy Technology Data Exchange (ETDEWEB)

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from ...

2010-01-01

106

Inventory determination of low and intermediate level radioactive waste of Paks Nuclear Power Plant origin  

International Nuclear Information System (INIS)

In the execution of disposal of low and intermediate level radioactive wastes, it is important to evaluate accurately the kind and quantity of each radionuclide in the wastes. For such an evaluation, correlation of non-gamma-emitting nuclides based on gamma-emitting nuclides is recommended and regarded as a partial method. This method necessitates a completion of a highly accurate and reliable nondestructive assay system of gamma-emitting nuclides for partical use. In 1992, in support of the new waste disposal program in Hungary, Paks NPP initiated a waste characterization program to determine the radiological properties of its rad wastes. A segmented gamma scanning system has been set up to measure the gamma-emitting nuclides in 2000 litre low level drums following in-drum compaction. In the framework of the program a radiochemical analysis ...

107

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger neutron flux (7.3 x 10[sup 7] n/cm[sup 2]/s) ...

1992-01-01

108

TECAB - Totally Endoscopic Coronary Artery Bypass  

Medline Plus

... CT angiograph for the peripheral rteries. a beautiful 3D-vision on the structures inside e chest. Okay. ... have an angled camera here. This is a 3D camera, and the surgeon has got th What ...

109

MTF analysis of the MURR real-time neutron radiography facility  

International Nuclear Information System (INIS)

In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a ...

1982-04-01

110

Inactivation of aflatoxin B1 by using the synergistic effect of hydrogen peroxide and gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Inactivation of aflatoxin B1 was studied by using gamma radiation and hydrogen peroxide. A 100-krad dose of gamma radiation was sufficient to inactivate 50 micrograms of aflatoxin B1 in the presence of 5% hydrogen peroxide, and 400 krad was required for total degradation of 100 micrograms of aflatoxin in the same system. Degradation of aflatoxin B1 was confirmed by high-pressure liquid chromatographic and thin-layer chromatographic analysis. Ames microsomal mutagenicity test showed loss of aflatoxin activity. This method of detoxification also reduces the toxin levels effectively in artificially contaminated groundnuts.

1989-02-01

111

CP property of the Higgs at the #gamma##gamma# colliders using tt-bar production  

International Nuclear Information System (INIS)

We present results of an investigation to study CP violation in the Higgs sector in tt-bar production at a #gamma##gamma#-collider, via the process #gamma##gamma# #-># #phi# #-># tt-bar where the #phi# is a scalar with indeterminate CP parity. The study is performed in a model independent way parametrising the CP violating couplings in terms of six form factors #left brace#R(S_#gamma#), T(S_#gamma#), R(P_#gamma#), T(P_#gamma#), S_t, P_t#right brace#. The CP violation is reflected in the polarisation asymmetry of the produced top quark. We use the angular distribution of the decay lepton from t/t-bar as a diagnostic of this polarisation asymmetry and hence of the CP mixing, after showing that the asymmetries in the angular distribution are independent of any CP violation in the tbW vertex. We construct combined asymmetries in the initial state lepton ...

2003-09-01

112

Some tests on measuring methods for indoor radon using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

Two methods for measuring indoor radon concentrations using activated charcoal have been tested. The first method is the well-known technique with direct gamma-measurements on the exposed canister after the sampling period. The other method uses a thermoluminescence dosemeter placed in the charcoal canister, giving an integrated value of the radon concentration.

1985-10-01

113

Use of portable HPGE detector and multichannel analyzer for in-situ gamma spectrometry of soil  

International Nuclear Information System (INIS)

Measurement of fission and activation products in the soil or over a plane grass land of a nuclear power station environment is required to find out the long term changes. The inventory of radionuclides in the soil is routinely determined by soil sampling, processing and gamma spectrometry in the laboratory. The method although is proven and accurate is time consuming and largely dependent on homogenous distribution. Therefore, an alternative and rapid method of in-situ gamma spectrometry using portable devices was standardized to determine the concentration of radionuclides in soil, for regular environmental monitoring as well as during emergency condition. The paper presents the methodology, ready to use factors and compares the results of a few measurements made in the environment of Tarapur Atomic Power Station by both in-situ and laboratory methods. (author)

2005-11-23

114

Measurement of liquid nitrogen level by radiation  

Energy Technology Data Exchange (ETDEWEB)

The measurement of level in the liquid nitrogen vessel has been carried out by the weight conversion method using weigher or by putting directly a stick in the vessel. On a large CE tank, the pressure difference was read by manometer. These methods can not be used when the vessel does not put on the weigher or the pipe for manometer is stopped. We noticed the interaction between radiation ({gamma}-ray) and substance and applied it to determine the liquid nitrogen level. The results proved it the easy method for measurement of the level in the large CE tank. Cesium 137 ({gamma}-ray energy: 662 keV) was used as the radiation source. {gamma}-ray transmission dose was determined by GM survey meter. The liquid nitrogen level could be determined by using the change of the transmission dose with amount of liquid nitrogen. (S.Y.)

1995-07-01

115

Production of three vector bosons in #gamma# #gamma# colliders  

International Nuclear Information System (INIS)

The production of three vector bosons in #gamma# #gamma# collisions studying the reactions #gamma# + #gamma# #-># W"+ + W"- + Z"0 and #gamma# + #gamma# #-># W"+ + W"- + #gamma#. 12 refs., 4 figs., 2 tabs.

116

Gamma spectrometry calibrations with natural radioactive materials  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using {gamma} ray lines of {sup 214}Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for {sup 214}Bi are determined. (orig.).

1996-02-01

117

Gamma spectrometry calibrations with natural radioactive materials  

International Nuclear Information System (INIS)

Natural radioactive materials were used for detector calibration. We found that KCl is a very suitable material for this purpose. The efficiency curve shape was derived by using #gamma# ray lines of "2"1"4Bi normalised using a known quantity of KCl in the same geometry. The best fit was found by the least squares method. The summing correction coefficients for "2"1"4Bi are determined. (orig.).

118

Analysis of coupled neutron-gamma radiations by the multigroup Albedo method applied to multilayered slab shieldings  

International Nuclear Information System (INIS)

Full text: The principal nuclear design tools available to the shielding designer include diffusion approximation, transport theory, and Monte Carlo techniques. Full transport theory or Monte Carlo methods are routinely used for shielding analyses, where penetration investigations are more sensitive to directional aspects. However, the aim of this paper is to illustrate the coupled neutron-gamma Albedo method particularly as applied to problems of shielding analysis. The multigroup Albedo method is applied to coupled neutron-gamma radiations considering 'n' neutron energy groups and 'g' gamma energy groups to estimate the probabilities of transmission through, absorption in, and reflection from shieldings composed by multiple material layers, 'm' slabs, in which no fission occurs. In this study, these energy groups were selected in order to minimize upscattering ...

119

FFTF reactor-characterization program: gamma-ray measurements and shield characterization  

Science.gov (United States)

A series of experiments is to be made during the acceptance test program of the Fast Flux Test Facility (FFTF) to measure the gamma ray characteristics of the Fast Test Reactor (FTR) and to establish the performance characteristics of the reactor shield. These measurements are a part of the FFTF Reactor Characterization Program (RCP). Detailed plans have been developed for these experiments. During the initial phase of the Characteristics Program, which will be carried out in the In-Reactor Thimble (IRT), both active and passive measurement methods will be employed to obtain as much information concerning the gamma ray environment as is practical. More limited active gamma ray measurements also will be made in the Vibration Open Test Assembly (VOTA).

120

Computer simulation of the initial rafting process of a nickel-base single-crystal superalloy  

Energy Technology Data Exchange (ETDEWEB)

Rafting of the {gamma}/{gamma}{prime} morphology of nickel-base superalloys is a well-known phenomenon during high-temperature deformation. The initial stages of this type of directional coarsening were modeled two-dimensionally by the method of finite elements (FEs) using an energy-perturbation approach. In addition to the elastic energy density, the effect of the local difference of the hydrostatic stresses in {gamma} and {gamma}{prime} in combination with the different lattice parameters of the two phases was considered in the calculations as a further driving force. From the results of modeling, the deformation-induced internal stresses and strains were determined and used to evaluate the direction-dependent lattice parameters and lattice misfits of the two phases. The results agree well with experimentally determined values.

2000-03-01

121

Burn-up measurement of irradiated nuclear fuel by means of micro-gamma scanning  

International Nuclear Information System (INIS)

The Cs-137 radioactivity of a neutron-irradiated nuclear fuel sample has been measured by means of a micro-gamma scanning system which is associated with a high purity Ge detector. Subsequently the burn-up has been calculated from the Cs-137 radioactivity data and then compared with the values from the theoretical computation and chemical anaylsis. The burn-up value obtained with the gamma-scanning system seems to be reasonably agreeable with that of the chemical anaylsis provided that the statistical error in the experiments is taken into account. It is revealed that the burn-up data from the theoretical approach is slightly higher than those of micro-gamma scanning and chemical analysis methods. (Author).

122

The effects of applied magnetic fields on the {alpha}/{gamma} phase boundary in the Fe-Si system  

Energy Technology Data Exchange (ETDEWEB)

The CALPHAD (calculations of phase diagrams) method is used to examine the effects of applied magnetic fields on the {alpha}/{gamma} phase boundary in the Fe-Si system in the paramagnetic state. The reported susceptibility data for pure Fe is first re-evaluated. The contributions to the total Gibbs energy of the ferrite ({alpha}) and austenite ({gamma}) from the external fields are calculated based on the Curie-Weiss law and the re-evaluated susceptibility data. The Fe-Si phase diagram on the Fe-rich side as a function of applied field is calculated using the Thermo-Calc(TM) package. With increasing field strength, the {gamma} loop shrinks monotonically; that is, the {alpha}/{gamma}-Fe transition temperature increases while that for {gamma}/{delta}-Fe transition decreases, albeit more slowly. Finally, in conformance with the existing CALPHAD databank, ...

2006-07-21

123

The "7Be(#alpha#,#gamma#)"1"1C and "7Li(#alpha#,#gamma#)"1"1B reactions in a microscopic three-cluster model  

International Nuclear Information System (INIS)

The "7Be(#alpha#,#gamma#)"1"1C and "7Li(#alpha#,#gamma#)"1"1B reactions are investigated in the three-cluster Generator Coordinate Method. The microscopic wave functions are described from #alpha# and "3He ("3H) clusters, with two coupling modes: #alpha#+"7Be ("7Li) and "3He ("3H)+"8Be. Different internal states of "7Be ("7Li) and "8Be are taken into account. The model is tested on "1"1C and "1"1B spectroscopic properties, which agree fairly well with experiment. We suggest that, in both nuclei, the (3)/(2)"- and (5)/(2)"- states located close to the #alpha#+"7Be ("7Li) threshold, are intruder states. The "7Be(#alpha#,#gamma#)"1"1C and "7Li(#alpha#,#gamma#)"1"1B reaction rates are calculated for temperatures up to 10"9 K. A strong enhancement is found with respect to the reaction rates currently used in astrophysical calculations. ((orig.)).

124

{gamma}-Irradiation-induced preparation of Ag and Au nanoparticles and their characterizations  

Energy Technology Data Exchange (ETDEWEB)

Using {gamma}-irradiation-induced reduction in the field of a {sup 60}Co {gamma}-ray source, colloidal silver and gold nanoparticles were prepared from their corresponding metal salts in aqueous solution and compared with those by chemical reduction. The radiation-based method provided silver nanoparticles with higher concentration and narrower size distribution than those obtained by chemical reduction method while there was no significant difference between the two strategies for the preparation of gold nanoparticles. {gamma}-Irradiation of 1.0 x 10{sup -3} M AgNO{sub 3} solution resulted in nearly 100 times more highly concentrated silver colloids than those by citrate reduction. Furthermore, the radiation method could lead to more highly concentrated silver colloids by simply increasing the concentration of AgNO{sub 3} solution up to 2.0 x 10{sup -2} M. The ...

2007-10-15

125

Semileptonic b to u transition  

CERN Document Server

Experimental studies of charmless semileptonic B decays can be broadly categorized into inclusive and exclusive measurements depending on how the final states are treated. The inclusive method measures the decay rate $\\Gamma(B \\to X_u \\ell \

2007-01-01

126

Effect of Peroxisome Proliferator-Activated Receptor Gamma Agonist (Pioglitazone) and Methotrexate on Disease Activity in Rheumatoid Arthritis (Experimental and Clinical Study)  

UK PubMed Central (United Kingdom)

Objective:To investigate the combined effect of both pioglitazone and methotrexate on disease activity of rheumatoid arthritis in a biphasic study; experimental and clinical.Methods:Experimentally:...Full Text Available

127

A unified framework for capturing facial images in video surveillance systems using cooperative camera system  

Science.gov (United States)

Low resolution and un-sharp facial images are always captured from surveillance videos because of long human-camera distance and human movements. Previous works addressed this problem by using an active camera to capture close-up facial images without considering human movements and mechanical delays of the active camera. In this paper, we proposed a unified framework to capture facial images in video surveillance systems by using one static and active camera in a cooperative manner. Human faces are first located by a skin-color based real-time face detection algorithm. A stereo camera model is also employed to approximate human face location and his/her velocity with respect to the active camera. Given the mechanical delays of the active camera, the position of a target face with a given delay can be estimated using a ...

2008-04-01

128

The application of irradiation techniques for food preservation and processing improvement  

Energy Technology Data Exchange (ETDEWEB)

This project has intended to develop alternative techniques to be used in food industry for food processing and utilization by safe irradiation methods. For improvement of rheology and processing in corn starch by irradiation, the production of modified starch with low viscosity as well as with excellent viscosity stability became feasible by the control of gamma irradiation dose levels and the amount of added inorganic peroxides to starch. Also, this project was developed the improvement methods of hygienic quality and long-term storage of dried red pepper by gamma irradiation. And, in Korean medicinal plants, 10 kGy gamma irradiation was effective for improving sanitary quality and increasing extraction yield of major components. For the sanitization of health and convenience foods, gamma irradiation was more effective than ozone treatment in decontamination ...

1997-09-01

129

Neutron and gamma transport in air by TRIPOLI-2 time dependent energy deposition and electron current calculation  

International Nuclear Information System (INIS)

The electromagnetic field due to an air explosion is here studied: neutron and the gamma-rays, generated by neutronic reactions, deposit energy which ionizes atmosphere; recoil electrons are also created by gamma collisions. This data set allows to solve the Maxwell equations which manage the electromagnetic field. The TRIPOLI-2 code studies the coupled neutron-gamma transport in 3D- geometries by the Monte Carlo method. The code has been modified to calculate the photon energy deposited in matter and the recoil electron current created by Compton effect. The method is tested wiht a simple case; then neutron and gamma transport is studied in air kerma, deposited photon energy, electron current are calculated as functions of space and time and the contributions of the different neutronic reactions are separately evaluated. The calculations presented here are only ...

1988-09-12

130

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the ...

131

Automatic Gamma-Scanning System for Measurement of Residual Heat in Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In Sweden, spent nuclear fuel will be encapsulated and placed in a deep geological repository. In this procedure, reliable and accurate spent fuel data such as discharge burnup, cooling time and residual heat must be available. The gamma scanning method was proposed in earlier work as a fast and reliable method for the experimental determination of such spent fuel data. This thesis is focused on the recent achievements in the development of a pilot gamma scanning system and its application in measuring spent fuel residual heat. The achievements include the development of dedicated spectroscopic data-acquisition and analysis software and the use of a specially designed calorimeter for calibrating the gamma scanning system. The pilot system is described, including an evaluation of the performance of the spectrum analysis software. Also described are the ...

2007-03-15

132

Estimation of armature condition in concrete with gamma-absorption method  

International Nuclear Information System (INIS)

Bases of the algorithm for assessing the reinforcement status in reinforced concrete products by gamma-absorption method are presented. Analytical equations are obtained for estimation of error of the parameter characterizing the degree of reinforcement destruction. It is recommended to use high-energy Bremsstrahlung sources-betatrons of 4-10 MeV maximum energy for testing products of 500-600 mm thick. Linear radiation attenuation factor (LAF) of concrete in estimated equation is replaced by effective LAF of concrete, and LAF of reinforcement and corrosion materials - by differential LAF. Corresponding LAF of nonevident form in the algorithm is assessed by the results of processing of direct-shadow radiographs of defectometers

133

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame ...

2000-07-01

134

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a ...

2000-01-01

135

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

International Nuclear Information System (INIS)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the ...

2009-03-01

136

Alternative Measuring Approaches in Gamma Scanning on Spent Nuclear Fuel  

Energy Technology Data Exchange (ETDEWEB)

In the future, the demand for energy is predicted to grow and more countries plan to utilize nuclear energy as their source of electric energy. This gives rise to many important issues connected to nuclear energy, such as finding methods that can verify that the spent nuclear fuel has been handled safely and used in ordinary power producing cycles as stated by the operators. Gamma ray spectroscopy is one method used for identification and verification of spent nuclear fuel. In the specific gamma ray spectroscopy method called gamma scanning the gamma radiation from the fission products Cs-137, Cs-134 and Eu-154 are measured in a spent fuel assembly. From the results, conclusions can be drawn about the fuels characteristics. This degree project examines the possibilities of using alternative measuring approaches when using the ...

2007-06-15

139

Comparison of the e"+e"-, #gamma#e, #gamma##gamma# linear colliders  

International Nuclear Information System (INIS)

The possibility to transform the future linear e"+e"-colliders into the #gamma#e and #gamma##gamma# colliders with approximately the same energies and luminosities was shown earlier. Their properties are compared from the point of view of possible physical investigations on them. 10 refs.; 1 tab.

1992-06-02

140

$\\gamma/\\phi_3$ at hadron colliders  

CERN Document Server

$\\gamma/\\phi_3$ at hadron colliders

2011-01-01

141

Plasma dynamics in PF-1000 device under full-scale energy storage: I. Pinch dynamics, shock-wave diffraction, and inertial electrode  

International Nuclear Information System (INIS)

This paper (paper I) presents the first part of results obtained with the PF-1000 facility for the first time at its upper energy limit (?1 MJ). Special attention is paid here to plasma ('pinch') dynamics, which was investigated in relation to its electro-technical and radiation (especially neutron) characteristics with the help of a number of diagnostics, both time-integrated and with nanosecond temporal resolution. In these methods we utilized a Rogowski coil for the routine electro-technical measurements, visual multi-frame and streak cameras, soft x-ray pin-hole multi-frame cameras, PIN-diode assembly and PM tubes with scintillators for soft and hard x-rays as well as for neutron investigations together with a set of activation counters. In particular, the temporal cross correlation of different phenomena taking place during the discharge was investigated. The pinch's longevity appears to be 10-15 times larger than the ...

2007-04-07

142

Measuring q sub 0 using supernovae at z approx 0. 3  

Energy Technology Data Exchange (ETDEWEB)

The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this system should find one supernova ...

1992-07-01

143

Detection of Second-Layer Corrosion in Aging Aircraft Fuselage  

International Nuclear Information System (INIS)

A Digital X-ray imaging system using Compton backscattering has been developed to obtain a cross-sectional profile and mass loss of corroded lap-splices of aging aircraft from density variation. A slit-type camera was designed to focus on a small scattering volume inside the material, from which the backscattered photons are collected by a collimated scintillator detector for interpretation of material characteristics. The cross section of the lap-joint is scanned by moving the scattering volume through the thickness direction of the specimen. The mass loss of each layer has been estimated from a Compton backscatter A-scan to obtain the thickness of each layer including the aluminum sheet, the corrosion layer and the sealant. Quantitative information such as location and width of planar corrosion in the lap splices of fuselages is obtained by deconvolution using a nonlinear least-square error minimization method(BFGS ...

2006-12-01

144

A new method of heat transfer augmentation by means of foreign gas jet impingement in liquid bath  

International Nuclear Information System (INIS)

The authors discuss a two-phase two-component experimental system developed to study enhancement of heat transfer from a vertical chip size heater to surrounding liquid (Freon 113 or Ethanol) due to air jet impingement. Heat transfer coefficient was measured as function of jet velocity, heat flux and the distance between exit of jet tube and heated surface. The injector was placed very close to the hot surface. It was found that the heat transfer was notably enhanced with foreign gas impingement, especially in the cases of small temperature differences between wall and coolant. In fact for higher jet velocities the heat transfer coefficients tended to infinite while the temperature differences between wall and coolant were zero. The heat transfer coefficients decreased with the increasing of heat flux. High-speed camera was used to study the behaviour of the gas bubbles which play very important role in the heat transfer process. A physical model of simultaneous ...

1985-10-01

145

Partial width fluctuation method of determining nuclear level density  

Energy Technology Data Exchange (ETDEWEB)

A new method of determining the nuclear level density is presented. This method is based on the statistical analysis of the partial width fluctuations appearing in an excitation function of the radiative proton capture. The method was applied in the case of the /sup 88/Sr(p,..gamma..sub(..omega..))/sup 89/Y and /sup 89/Y(p,..gamma..sub(..omega..))/sup 90/Zr reactions. The density of levels with spin I/sup -/ in /sup 90/Zr and the densities of levels with spins 1/2/sup +/ and 3/2/sup +/ in /sup 89/Y at excitation energies from 10.9 to 11.6 MeV and from 9.3 to 10.8 MeV respectively, were determined with an uncertainty of about 35%.

1982-04-12

146

Development of food preservation and processing techniques by radiation  

International Nuclear Information System (INIS)

Development of food preservation and processing techniques by radiation was performed. Gamma irradiation at 2-10 kGy is considered to be an effective method to control pathogenic bacteria in species including Escherichia coli O157:H7. Gamma irradiation at 5 kGy completely eliminated pathogenic bacteria in beef. Gamma irradiation at such doses and subsequent storage at less than 4 deg C could ensure hygienic quality and prolong the microbiological shelf-life resulting from the reduction of spoilage microorganisms. Gamma irradiation on pre-rigor beef shortens the aging-period, improves tenderness and enhances the beef quality. And, a new beef processing method using gamma irradiation, such as in the low salt sausage and hygienic beef patty was developed. Safety tests of gamma-irradiated meats(beefs: 0-5 kGy; porks: 0-30 ...

1988-04-18

147

Development of a neutron/. gamma. ray radiation monitor  

Energy Technology Data Exchange (ETDEWEB)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/..gamma.. ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time ..gamma.. spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded ..gamma.. spectra created by the photopeak-Compton edge combination in the plateau portion ...

1983-01-01

148

Development of a neutron/#gamma# ray radiation monitor  

International Nuclear Information System (INIS)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/#gamma# ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time #gamma# spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded #gamma# spectra created by the photopeak-Compton edge combination in the plateau portion of the ...

1983-01-01

149

Development of a Neutron/gamma Ray Radiation Monitor.  

Science.gov (United States)

Personnel radiation monitoring is essential to the operation of any nuclear facility and work in this area continues to strive for an accurate determination of personnel dose. In particular recent attention has been focused upon the need to improve the accuracy of neutron dosimetry, mainly because of their high Relative Biological Effectiveness. In this work the feasibility of using the NE-213 liquid scintillation detector as an efficient neutron/gamma ray radiation monitor is demonstrated. Derivative method spectrum unfolding used in MATXUF for on-line analysis of fast neutron spectra has also been applied to real time gamma spectrum unfolding (MATXUF2), making possible simultaneous on-line monitoring of both fast neutrons and gammas. To eliminate the negative fluxes in the unfolded gamma spectra created by the photopeak-compton edge combination in the plateau portion of the knee ...

1983-01-01

150

Burnup determination of spent nuclear fuel in the pool  

Energy Technology Data Exchange (ETDEWEB)

A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used ...

1998-06-01

151

Production of three vector bosons in {gamma} {gamma} colliders; Producao de tres bosons vetoriais em {gamma} {gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The production of three vector bosons in {gamma} {gamma} collisions studying the reactions {gamma} + {gamma} {yields} W{sup +} + W{sup -} + Z{sup 0} and {gamma} + {gamma} {yields} W{sup +} + W{sup -} + {gamma}. 12 refs., 4 figs., 2 tabs.

1994-12-31

152

Inf-convolution of g_\\Gamma-solution and its applications  

CERN Document Server

A risk-neutral method is always used to price and hedge contingent claims in complete market, but another method based on utility maximization or risk minimization is wildly used in more general case. One can find all kinds of special risk measure in literature. In this paper, instead of using market modified risk measure, we use a kind of risk measure induced by g_\\Gamma-solution or the minimal solution of a Constrained Backward Stochastic Differential Equation (CBSDE) directly when constraints on wealth and portfolio process comes to our consideration. Such g_\\Gamma-solution and the risk measure generated by it is well defined on appropriate space under suitable conditions. We adopt the inf-convolution of convex risk measures to solve some optimization problem. A dynamic version risk measures defined through g_\\Gamma-solution and some similar results about optimal problem can ...

2011-01-01

153

Quality control and evaluation for environmental radiological baseline study of Guangdong Daya Bay nuclear power station  

International Nuclear Information System (INIS)

The main points of quality control methods and technique of environmental radiological baseline study of Guangdong Daya Bay Nuclear Power Station are reported. Results of intercalibration of international and inland laboratories are given. The random chosen samples are checked and compared with two measurement methods. The data obtained in Daya Bay environment are put to the correlation statistics test using the linear regression analysis method between the correlative items such as "4"0K activity by gamma spectrum measurement and potassium content by chemical analysis, total #alpha#(#beta#) activity and nuclide content, as well as environmental gamma radiation dose rate and TLD accumulation dose. The data of Daya Bay environmental radioactivity baseline level show good concordance and reliability.

154

A Simulation Study on a Radioactive Nuclide's Distribution within a Fuel rod by a Tomographic Gamma Scanning  

Energy Technology Data Exchange (ETDEWEB)

Gamma scanning measurements are used to determine the radioactive nuclides from an irradiated fuel rod in a hot cell which is a routine task in the Irradiated Materials Examination Facility (IMEF) of the Korea Atomic Energy Research Institute (KAERI), Total gamma spectra of radioactive nuclides and the atomic ratio of {sup 134}Cs to {sup 137}Cs in a few segments of a single fuel rod are measured by the present gamma scanning system. For the purpose of determining the radioactive nuclide's distribution in detail within a fuel rod quantitatively, we attempt to upgrade the present gamma scanning system in this paper, therefore, an investigation of the feasibility of the tomographic gamma scanning (TGS) technique, which is one of the promising nondestructive assay (NDA) methods is proposed. The TGS technique is an efficient method and ...

2006-07-01

155

Rayleigh Laser Guide Star Systems UnISIS Bow Tie Shutter and CCD39 Wavefront Camera  

CERN Document Server

Laser guide star systems based on Rayleigh scattering require some means to deal with the flash of low altitude laser light that follows immediately after each laser pulse. These systems also need a fast shutter to isolate the high altitude portion of the focused laser beam to make it appear star-like to the wavefront sensor. We describe how these tasks are accomplished with UnISIS, the Rayleigh laser guided adaptive optics system at the Mt. Wilson Observatory 2.5-m telescope. We use several methods: a 10,000 RPM rotating disk, dichroics, a fast sweep and clear mode of the CCD readout electronics on a 10 $\\mu$s timescale, and a Pockel's cell shutter system. The Pockel's cell shutter would be conventional in design if the laser light were naturally polarized, but the UnISIS 351 nm laser is unpolarized. So we have designed and put into operation a dual Pockel's cell shutter in a unique bow tie arrangement.

2002-01-01

156

Medical image transmission via communication satellite. Evaluation of bone scintigraphy  

International Nuclear Information System (INIS)

As compared with terrestrial circuits, the communication satellite possesses superior characteristics such as wide area coverage, broadcasting, high capacity, and robustness to disasters. Utilizing the narrow band channel (64 kbps) of the geostationary satellite JCSAT 1 located at the altitude of 36,000 km above the equator, the authors investigated satellite-relayed medical imagings by video signals, with bone scintigraphy as a model. Each bone scintigraphy was taken by a handy-video camera, digitalized and transmitted from faculty of technology located at 25 kilometers apart from our department. Clear bone scintigraphy was obtained via satellite, as seen on the view box. Eight nuclear physicians evaluated 20 cases of bone scintigraphy. ROC (Receiver Operating Characteristic) analysis was performed between the scintigraphies on view box and via satellite by the rating method. The area under the ROC curve was 91.6#+-#2.6% via satellite, and ...

157

HST/ACS observations of shell galaxies: inner shells, shell colours and dust  

CERN Document Server

AIM:Learn more about the origin of shells and dust in early type galaxies. METHOD: V-I colours of shells and underlying galaxies are derived, using HST Advanced Camera for Surveys (ACS) data. A galaxy model is made locally in wedges and subtracted to determine shell profiles and colours. We applied Voronoi binning to our data to get smoothed colour maps of the galaxies. Comparison with N-body simulations from the literature gives more insight to the origin of the shell features. Shell positions and dust characteristics are inferred from model galaxy subtracted images. RESULT: The ACS images reveal shells well within the effective radius in some galaxies (at 1.7 kpc in the case of NGC 5982). In some cases, strong nuclear dust patches prevent detection of inner shells. Most shells have colours which are similar to the underlying galaxy. Some inner shells are redder than the galaxy. All six shell galaxies show out of dynamical equilibrium dust ...

2007-01-01

158

First RAVEN flight set for September  

Energy Technology Data Exchange (ETDEWEB)

An unmanned aerial vehicle called RAVEN, said to be capable of remote tracking of onshore and offshore oil and gas facilities, has been developed by a group of graduate students from Memorial University of Newfoundland. RAVEN is claimed to be capable of performing a number of tasks under its own control without the need for human intervention, including checking onshore pipelines for damage, or scouting the path of hazardous icebergs offshore. The RAVEN was created to meet the need for real time iceberg tracking and early hazard detection, supplementing or replacing the present method of RADARSAT images and tracking by manned aircraft. The RAVEN can be launched from any platform; it can fly under conditions that would be too dangerous for a manned aircraft. Currently in the prototype stage, the first trial flight for the RAVEN is expected to take place in September 2002. The first flight will consist of five GPS waypoints set relatively close together in a pattern ...

2002-08-01

159

Studies on application of radiation and radioisotopes -The application of irradiation techniques for food preservation and process improvement-  

Energy Technology Data Exchange (ETDEWEB)

The project was designed to solve the infra structural problem required for commercialization of food irradiation. In improvement of physical properties of corn starch, gamma irradiation was effective for increasing glucose productivity and for substituting traditional modified starches (acid modified starch, oxidized starch). In immobilization of microorganisms, the mass production method of natural red pigment was developed by using immobilized mold pellets. In Korean medicinal plants, 10 kGy gamma irradiation was effective for improving sanitary quality and increasing extraction yield. In evaluation of wholesomeness, gamma irradiated red ginseng could be safe on the genotoxic point of view. And also, six items of irradiated foods approved for human consumption from Korea ministry of health and welfare in May 19, 1995. 30 figs, 20 tabs, 54 refs. (Author).

1995-07-01

160

Interpretation of gamma-scanning data from the ORR demonstration elements  

Energy Technology Data Exchange (ETDEWEB)

The HEU and LEU fuel elements used in the ORR whole-core demonstration were gamma-scanned to determine the axial distribution of the {sup 140}La and {sup 137}Cs activities. Analysis of this data is now complete. From the {sup 140}La activity distributions cycle-averaged powers were determined while the {sup 137}Cs data provided a measure of the final {sup 235}U burnup in the fuel elements. A method for calculating correction factors for activity gradients transverse to the fuel element axis is presented and is applied to the first mixed core used in the demonstration during the gradual transition to an all LEU core. Results based on the gamma-scanning of the LEU fuel followers are also presented. Improved burnup calculations against which the experimental results are to be compared are now in progress. 7 refs., 21 figs., 3 tabs.

1989-01-01

161

Cross-section libraries and analysis of fast reactor benchmarks  

International Nuclear Information System (INIS)

Using indigenously developed computer program, coupled neutron gamma multi-group libraries have been generated from MA TXS-NJOY files. The MATXS format contains all the details for each reaction. Temperature and dilution factor dependent cross-sections have been generated and used in discrete ordinates method for benchmark studies of fast critical experiments. We have analyzed criticality benchmarks, which includes CSEWG fast critical benchmarks, "2"3"3U and Pu spheres and enriched uranium spheres using 30-group neutron cross-sections. Neutron and gamma spectra for spheres with point neutron source at the center, are also calculated with 42-group coupled neutron gamma cross-sections. (author)

2005-11-01

162

Unfolding of differential energy spectra in the MAGIC experiment  

Energy Technology Data Exchange (ETDEWEB)

The paper describes the different methods, used in the MAGIC experiment, to unfold experimental energy distributions of cosmic ray particles ({gamma}-rays). Questions and problems related to the unfolding are discussed. Various procedures are proposed which can help to make the unfolding robust and reliable. The different methods and procedures are implemented in the MAGIC software and are used in most of the analyses.

2007-12-21

163

Multigroup Albedo Method applied to coupled neutron-gamma radiations shielding; Metodo multigrupo do albedo aplicado a blindagem de radiacoes neutron-gama acoplados  

Energy Technology Data Exchange (ETDEWEB)

Shielding calculations for neutron-gamma radiation are usually done by using the full Theory of Transport or the Monte Carlo Techniques. After some works based on the Albedo Method, the shielding calculations for neutron-gamma radiation have a reliable tool with great didactical value which shows its clarity and simplicity for the resolution of cases that involve neutrons and photon shielding in nonmultiplying media. The excellent results of these works have motivated the elaboration and the development of this study that will be presented in this dissertation. The balance of a neutronic current entering a shield of two layers considering the coupling neutron-gamma will be determined by the Albedo Method. The shield will be composed of a layer of iron and another one of manganese with 10 cm of thickness each. The arrays of the materials coefficients will be obtained from the ANISN ...

2001-07-01

164

Multigroup Albedo Method applied to coupled neutron-gamma radiations shielding  

International Nuclear Information System (INIS)

Shielding calculations for neutron-gamma radiation are usually done by using the full Theory of Transport or the Monte Carlo Techniques. After some works based on the Albedo Method, the shielding calculations for neutron-gamma radiation have a reliable tool with great didactical value which shows its clarity and simplicity for the resolution of cases that involve neutrons and photon shielding in nonmultiplying media. The excellent results of these works have motivated the elaboration and the development of this study that will be presented in this dissertation. The balance of a neutronic current entering a shield of two layers considering the coupling neutron-gamma will be determined by the Albedo Method. The shield will be composed of a layer of iron and another one of manganese with 10 cm of thickness each. The arrays of the materials coefficients will be obtained from the ANISN ...

2001-01-01

165

Tritium monitor with improved gamma-ray discrimination  

Energy Technology Data Exchange (ETDEWEB)

Apparatus and method for selective measurement of tritium oxide in an environment which may include other radioactive components and gamma radiation, the measurement including the selective separation of tritium oxide from a sample gas through a membrane into a counting gas, the generation of electrical pulses individually representative by rise times of tritium oxide and other radioactivity in the counting gas, separation of the pulses by rise times, and counting of those pulses representative of tritium oxide. The invention further includes the separate measurement of any tritium in the sample gas by oxidizing the tritium to tritium oxide and carrying out a second separation and analysis procedure as described above.

1985-01-01

166

Three-dimensional data processing for time resolved gamma-ray spectrometry  

International Nuclear Information System (INIS)

A new acquisition and evaluation procedure has been introduced for the measurement of time-dependent processes in gamma-ray spectrometry, in order to extract more information, including half-lives, from the data recorded during acquisition and to enable a more comprehensive analysis of the results. These advanced, off-line data evaluation techniques improve the selectivity and the background subtraction and make it possible to estimate the important analytical parameters (e.g., half-lives) more accurately than with the usual decay curve fitting method. (author)

167

Spectral studies of intermediate species formed in one-electron reactions of bovine liver catalase at room and low temperatures. A comparison with peroxidase reactions  

Energy Technology Data Exchange (ETDEWEB)

The reactions of native bovine catalase with superoxide and solvated electrons have been investigated using three different methods for generating these reducing substrates: [gamma]-radiolysis of oxygenated or deaerated buffer solutions in the presence of an OH radical scavenger; either xanthine or acetaldehyde with xanthine oxidase; and low-temperature (77 K) [gamma]-radiolysis of buffered ethylene glycol/water solutions with subsequent annealing of samples at 183 K. (Author).

1992-11-01

168

Simultaneous measurement of the neutron capture and fission yields of "2"3"3U  

International Nuclear Information System (INIS)

We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1 MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)

2007-04-22

169

Radiation-induced chemical modification of wood  

International Nuclear Information System (INIS)

The results of theoretical and experimental investigations, describing the effect of ionizing radiation on wood and its main components and methods for production of wood-plastic composites by means of radiation-induced chemical modification are generalized. Domestic and foreign experience in their production is systematized; physico-mechanical characteristics of new material, simulation and calculation of irradiating devices, as well as calculation and experimental study of #gamma#-radiation attenuation both by wood material and by wood of different species are given. Gamma sources ("6"0Co isotope, a hot loop of a nuclear reactor) as well as electron accelerators are considered as ionizing radiation sources.

1985-01-01

170

Modular symmetry in parametrically excited quantum oscillators  

Energy Technology Data Exchange (ETDEWEB)

It is shown that when a quantum mechanical oscillator is parametrically excited there are special values of the parameters for which the system will pass periodically through a lattice of coherent states associated with the modular group [Gamma]. It is shown that these [Gamma] transits can be used to determine unknown parameters. A method is given for detecting the transits experimentally and is made possible by the existence of three families of states associated with modular forms that are orthogonal to the lattice. For isotropic states the three families occur in [ital D]-mode systems with [ital D][gt]10, 14, and 26.

1993-11-29

171

Manufacturing of golf club using wood-plastic combination produced by. gamma. -irradiation  

Energy Technology Data Exchange (ETDEWEB)

Wood-plastic combination (WPC) was produced by {gamma}-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).

1992-01-01

172

Manufacturing of golf club using wood-plastic combination produced by #gamma#-irradiation  

International Nuclear Information System (INIS)

Wood-plastic combination (WPC) was produced by #gamma#-irradiation of persimmon impregnated with acrylonitrile and styrene. The hardness and strength of WPC obtained were higher than those of an unmodified wood. Thus, it was found that the WPC is suited for a head of golf club, because the Shore hardness value of WPC is 36% greater than that of unmodified wood. An impregnation method of monomers with some pigments could produce colored WPC without diminishing natural grain. Head of golf club could be manufactured from colored WPC in practice. (auhtor).

1992-01-01

173

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

174

Choice of energies in gamma-absorption method for layers thickness measuring of two-layers articles  

International Nuclear Information System (INIS)

Empirical formulae are proposed for the description of relation between optimum energies minimizing the mean-weighted error of gamma absorption measurement of the thickness of layers in two-layer products with the thickness of every layer from 30 up to 150 mm by carbon. Error of informational parameter approximation with the application of tables does not exceed 10% in case of non-accurate assessment of layers thickness not exceeding 2.5%. Generalized equation is derived which binds main parameters of the task and permits to choose optimum energies with the accuracy sufficient for practical purposes

175

Application of a 3-beam #gamma# densitometer to two-phase flow regime and density measurements  

International Nuclear Information System (INIS)

A method of using gamma radiation to determine the density and phase distribution in two-phase flows in pipes is described. Three collimated beams of radiation that pass through a pipe cross-section at different radial positions are used. A theory and computer program used to relate the measured attenuation of these beams to a three-parameter model of the phase distribution and to the average density and void fraction are discussed. Data obtained during both static and dynamic verification experiments using Lucite inserts are presented, as well as the results of several tests done in high pressure, steam-water flows.

1976-08-11

176

Achievements in testing of the MGA and FRAM isotopic software codes under the DOE/NNSA-IRSN cooperation of gamma-ray isotopic measurement systems  

Energy Technology Data Exchange (ETDEWEB)

DOE/NNSA and IRSN collaborated on a study of gamma-ray instruments and analysis methods used to perform isotopic measurements of special nuclear materials. The two agencies agreed to collaborate on the project in response to inconsistencies that were found in the various versions of software and hardware used to determine the isotopic abundances of uranium and plutonium. IRSN used software developed internally to test the MGA and FRAM isotopic analysis codes for criteria used to stop data acquisition. The stop-criterion test revealed several unusual behaviors in both the MGA and FRAM software codes.

2009-01-01

177

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

178

The Effect of Experience on Male Courtship and Mating Behaviors in a Cellar Spider  

Science.gov (United States)

... video recorded in an isolated booth under a Panasonic WV-CP470 video camera located in an environmentally ... ...

179

Sun rises on station era - Johnson Space Center - NASA  

Science.gov (United States)

Dec 4, 1998 ... throwing a single switch to as complex as the Spartan deploy and retrieve. ...... The camera, called the Acousto-Optic ...

180

SD 571 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

monitoring of open pit mining operations. INTRODUCTION. Aerial photography has long been a useful tool for geologists. Cameras ...

181

Genesis : Search for Origins | JPL | NASA  

Science.gov (United States)

(telescopes, cameras, mirrors, solar cookers); Explain to students that the Genesis spacecraft has a concentrator that collects special types of atoms from ...

182

FINAL REPORT CONTINUOUS SCANNING METEOROLOGICAL CAMERA SYSTEM FOR ...  

Science.gov (United States)

was deemed adequate and a cooling system designed utilizing the Melcor CP2-15- 10B thermoelectric module. Wall temperature achieved with this system was - 36 ...

183

Camera position estimation and feature extraction from an incomplete image of a landmark  

British Library Electronic Table of Contents (United Kingdom)

In the autonomous unmanned helicopter landing problem, the position of the unmanned helicopter relative to the landmark is very important. A camera carried on the unmanned helicopter can capture an image of the landmark. In earlier research, it was reported that the camera position could be estimated by features extracted from the landmark image. However, it is necessary that the landmark image should be complete, or with only slight deficiencies, in order for this estimation process to be possible. In this article, we report on an innovative design for an estimation made from a camera position giving an incomplete single image of the landmark. An adaptive neuro-fuzzy inference system (ANFIS) is used to construct the mapping relation between the features of complete and incomplete landmark...

2011-01-01

184

+ September 2006 - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Post-drive imaging included 360-degree view by the navigation camera and .... Sol 938: Opportunity completed another assessment of the clarity of the sky. ...

185

Synthesis and biodistribution of nitrido technetium-99m radiopharmaceuticals with dithiophosphinate ligands: a class of brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

The symmetrical complexes [{sup 99m}Tc][TcN(R{sub 2}PS{sub 2}){sub 2}] [R = CH{sub 3}, CH{sub 2}CH{sub 3}, CH{sub 2}CH{sub 2}CH{sub 3}, CH{sub 2}(CH{sub 3}){sub 2}], and the unsymmetrical complex [{sup 99m}Tc][TcN(Me{sub 2}PS{sub 2})(Et{sub 2}PS{sub 2})] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R{sub 2}PS{sub 2}]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding {sup 99}Tc-analogs prepared, at macroscopic level, by reacting the complex [{sup 99}TcNCl{sub 4}] [n-Bu{sub 4}N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two ...

1995-04-01

186

Synthesis and biodistribution of nitrido technetium-99m radiopharmaceuticals with dithiophosphinate ligands: a class of brain imaging agents  

International Nuclear Information System (INIS)

The symmetrical complexes ["9"9"mTc][TcN(R_2PS_2)_2] [R = CH_3, CH_2CH_3, CH_2CH_2CH_3, CH_2(CH_3)_2], and the unsymmetrical complex ["9"9"mTc][TcN(Me_2PS_2)(Et_2PS_2)] have been prepared, at tracer level, through a two-step procedure involving the preliminary formation of a prereduced technetium nitrido intermediate followed by substitution reaction onto this species by the appropriate dithiophosphinate ligand [R_2PS_2]Na. The chemical identity of the resulting complexes have been established by comparison with the corresponding "9"9Tc-analogs prepared, at macroscopic level, by reacting the complex ["9"9TcNCl_4] [n-Bu_4N] (n-Bu = n-butyl) with an excess of ligand in methanol, and characterized by elemental analyses and spectroscopic techniques. The complexes are neutral and lipophilic, and possess a square pyramidal geometry, with an apical Tc N group and two dithiophosphinate ligands spanning the four positions on the basal plane through the four sulfur atoms of the >PS_2 group. ...

1995-04-01

187

Quantitative bone scintigraphy. A study in patients with prostatic carcinoma  

International Nuclear Information System (INIS)

Quantitative bone scintigraphy was performed in patients with prostatic carcinoma before orchiectomy as well as two weeks, two and six months after operation. The count rate was recorded as serial gamma camera images over the lower thoracic and all lumbar vertebrae from 1 to 240 min and at 24 h after injection of "9"9"Tc"m-MDP. In almost all abnormal vertebrae an increased count rate was observed within one hour after injection. Most of the vertebrae which were considered normal at 4 h after injection, but had an increased 24h/4h ratio developed into abnormal vertebrae later in the study. The patients with normal bone scintigrams showed no change in "9"9Tc"m-MDP uptake during the study. The reproducibility of quantitative bone scintigraphy was found to be #+-# 7% (1 SD). In response to therapy, most of the patients with abnormal bone scintigrams showed an increase in count rate two weeks after operation followed by a decrease to the ...

1985-06-02

188

Optimizing the radiosensitive liquid-core microcapsules for the targeting of chemotherapeutic agents  

Energy Technology Data Exchange (ETDEWEB)

Microcapsules consisting of alginate and hyaluronic acid that can be decomposed by radiation are currently under development. In this study, the composition of the microcapsule material was optimized by changing the amounts of alginate and hyaluronic acid. Solutions of 0.025%, 0.05%, 0.1%, 0.2%, or 0.4% (wt./vol.) hyaluronic acid were mixed into a 0.2% alginate solution. To these mixtures, carboplatin (0.2 mmol) was added and the resulting material was used for the capsule preparation. The capsules were prepared by spraying the material into a CaCl{sub 2} solution (0.34 mol/l) using a microatomizer. These capsules were irradiated by a single dose of 2, 5, or 10 Gy {sup 60}Co {gamma}-ray radiation. Immediately after irradiation, the releasing of core content of microcapsule was determined, using a micro particle induced X-ray emission (PIXE) camera. The average diameter of the microcapsules was 22.3 {+-} 3.3 {mu}m, and that of the liquid core ...

2007-07-15

189

I-131 labelled peanut lectin renal kinetics in cis-platin induced tubular toxicity in dogs  

International Nuclear Information System (INIS)

Quantitative I-131 labelled Peanut lectin (I-131-PNA) renal clearance was determined in dogs before and after a 5 day single cycle cis-platinum chemotherapy regimen (0.5mg/Kg/day). Results were statistically compared with E.R.P.F. (I-131-Hippuran), G.F.R. (Tc-99m-DTPA), and serum biochemistry and correlated with histopathology. I-131-PNA clearance was significantly reduced in all dogs 5 days after cessation of cis-platinum treatment (mean #DELTA#S% = 71.3%) and similar reductions in the gamma camera derived renogram peak were demonstrated (mean #DELTA#S% = 65.8%). E.R.P.F. was noted to drop by a minor degree (mean #DELTA#S% = 20.9%) post treatment. G.F.R. was diminished (mean #DELTA#S% = 46.6%) and serum creatinine elevated (mean #DELTA#S% = 42.7%) in all dogs compared to their pretreatment values. Histopathology demonstrated variable degrees of tubular toxicity ranging from mild to severe. The degree of change of the I-131-PNA values was ...

1985-06-02

190

Autoradiographic analysis of radiolabeled anti-carcinoembryonic antigen monoclonal antibody CEA 102 in colorectal cancer using computed radiography  

Energy Technology Data Exchange (ETDEWEB)

Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with {sup 131}I-labeled intact CEA 102 or its F(ab'){sub 2}. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of {sup 131}I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted ...

1992-04-01

191

Autoradiographic analysis of radiolabeled anti-carcinoembryonic antigen monoclonal antibody CEA 102 in colorectal cancer using computed radiography  

International Nuclear Information System (INIS)

Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with "1"3"1I-labeled intact CEA 102 or its F(ab')_2. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of "1"3"1I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in ...

1992-01-01

192

Attention deficit hyperactivity disorder: binding of [{sup 99m}Tc]TRODAT-1 to the dopamine transporter before and after methylphenidate treatment  

Energy Technology Data Exchange (ETDEWEB)

Involvement of the dopaminergic system has been suggested in patients suffering from attention deficit hyperactivity disorder (ADHD) since the symptoms can be successfully treated with methylphenidate, a potent blocker of the dopamine transporter (DAT). This study reports the findings on the status of the DAT in adults with ADHD before and after commencement of treatment with methylphenidate, as measured using [{sup 99m}Tc]TRODAT-1. Seventeen patients (seven males, ten females, aged 21-64 years, mean 38 years) were examined before and after the initiation of methylphenidate treatment (3 x 5 mg/day). All subjects were injected with 800 MBq [{sup 99m}Tc]TRODAT-1 and imaged 3 h p.i. Single-photon emission tomography (SPET) scans were acquired using a triple-headed gamma camera. For semi-quantitative evaluation of the DAT, transverse slices corrected for attenuation were used to calculate specific binding in the striatum, with the cerebellum used ...

2000-10-01

193

Excited leptons and quarks at #gamma##gamma#/#gamma#e colliders  

International Nuclear Information System (INIS)

We discuss the search of excited leptons and quarks with spin 1/2 at #gamma##gamma# and at #gamma#e colliders. We show that #gamma##gamma# colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l"*l#gamma# transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).

194

Investigation of natural radionuclides in selected NORM-samples  

International Nuclear Information System (INIS)

A programme has been initiated by the Coordinating Office for Monitoring of enhanced natural radioactivity of the Federal Office for Radiation Protection to investigate different kinds of sample materials with enhanced naturally occurring radioactivity (NORM) such as scales from oilfield and naturally gasfield pipes, blast furnace sludge and sinter dust from the production of pig iron, as well as bauxit and red mud from the production of aluminium oxide. The aim of these investigations is to find proper preparation and measuring methods which allow, in particular, a sample treatment with optimised effort combined with a reliable determination of the specific activities of the dominating radionuclides. Of particular interest is the method of gamma-ray spectrometry, since this method has been used for most of our studies of sample materials. Due to different compositions of calibration and NORM-samples, ...

2005-09-20

195

Coupled neutron - #gamma#-ray diffraction: A method for accurate measurement of strains. Application to the study of the ferroelectric phase transition of KH_2PO_4  

International Nuclear Information System (INIS)

A method that employs simultaneous neutron and #gamma#-ray diffraction techniques is proposed for accurate measurements of strains with or without an applied electric field (0-100 kV m"-"1). Instead of an absolute determination of the position of the neutron Bragg peak, a relative measurement of the neutron and #gamma# peak positions is used and allows a determination of the lattice-parameter changes with an accuracy of within 2 x 10"-"6. This technique avoids systematic errors originating in sample rotations by taking advantage of a reference directly related to the crystal lattice. The method appears to be particularly important for crystals that exhibit structural phase transitions, as demonstrated by the measurement of the strain U_x_x in KH_2PO_4 crystals as a function of temperature and applied electric field. In this case the errors would amount to #+-#20%. The results demonstrate the need to ...

1987-12-01

196

Signatures of extra dimensions at e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The authors study the processes {gamma}e {r{underscore}arrow} {gamma}e and {gamma}{gamma} {r{underscore}arrow} {gamma}{gamma}, in the context of the proposal for Weak Scale Quantum Gravity (WSQG) with large extra dimensions. With an ultraviolet cutoff M{sub S} {approximately} 1 TeV for the effective gravity theory, the cross sections obtained for these processes at the Next Linear Collider (NLC), with the e{gamma} an {gamma}{gamma} options, deviate from the predictions of the Standard Model significantly. The results suggest that, for typical proposed NLC energies and luminosities, the predictions of WSQG can be tested in the range 1 TeV {approx{underscore}lt} M{sub S} {approx{underscore}lt} 10 TeV, making e{gamma} an {gamma}{gamma} colliders important tools for probing WSQG.

2000-01-26

197

Nondestructive techniques for the control of conditioned radioactive wastes  

International Nuclear Information System (INIS)

The final product of the radwaste conditioning process must satisfy certain requirments and physico-chemical properties in order to assure its safe long-term behaviour. Of course, the foreseen quality assurance and quality control should be conducted by means of non-destructive techniques. This work presents an over-view of various applicable non-destructive methods of analysis, showing their fields of investigation in testing waste packages, together with some arising practical problems. The most promising methods, such as eddy current testing, ultrasonic testing, #gamma#-scanning, #gamma#-spectroscopy, neutron counting and computerized tomography, are treated more deeply and some applications are presented. Particular attention is devoted to the development of a device based on computerized tomography; its essential components are reported and some design problems are also discussed.

2005-09-01

198

Low-temperature radiation polymerization of triethylene glycol. cap alpha. ,. omega. -dimethacrylate. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Kinetics of postradiation polymerization of triethylene glycol ..cap alpha.., ..omega..-dimethacrylate has been studied by calorimetric method. The low-temperature radiolysis has been studied by ESR method. The radiation-chemical yield of radicals on ..gamma..-irradiation by /sup 60/Co is determined being equal to 6+-1 1/100 ev. Transformation of the radicals spectrum into the spectrum of propagating macroradicals proceeds at 140 K. After the transition from glassy to liquid state (Tsub(g)=193 K) the intensive postpolymerization begins. During the polymerization the disappearance of radicals is observed. For the low-temperature region the effective activation energy of polymerization is determined beina equal to 50.7+-0.8 kJ/mol.

1984-04-01

199

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

200

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

201

Real-time neutron radiography at Texas A and M University  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The ...

1990-12-20

202

Real-time neutron radiography at Texas A and M University  

International Nuclear Information System (INIS)

A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The ...

1990-12-01

203

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are ...

2006-03-15

204

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

International Nuclear Information System (INIS)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated when low signals are collected with a ...

2006-03-01

205

#gamma##gamma# Cross-sections and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We summarize the predictions of different models for total #gamma##gamma# cross-sections. The experimentally observed rise of #sigma#_#gamma#_#gamma# with s radical _#gamma#_#gamma#, faster than that for #sigma#_p_-_b_a_r_p, #sigma#_#gamma#_p is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of #sigma#_#gamma#_#gamma# with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range 300< s radical_#gamma#_#gamma# <500 GeV. We further show that the difference in model predictions for ...

2001-10-11

206

Radiation damage and recovery in the light emittance efficiency and the attenuation length of barium fluoride scintillator  

International Nuclear Information System (INIS)

Radiation damage and its recovery in the light emittance efficiency and the attenuation length of barium fluoride (BaF_2) scintillator have been investigated. The light yield and transmittance of small samples of BaF_2 scintillator were measured after #gamma#-irradiation from 0.5x10"4 to 1.1x10"5 Gy for deterioration, and after sunlight exposure for recovery. Suspension of deterioration was observed both in light yield and in attenuation length at an integrated dose of #gamma#-rays of about 10"4 Gy. Fairly good and quick recovery of the deteriorated BaF_2 scintillator was obtained by sunlight exposure. Using a Monte Carlo simulation method, the dependence of the light emittance efficiency on #gamma#-irradiation and sunlight exposure was studied. It has been found that the light emittance efficiency, as well as the attenuation length, is influenced by #gamma#-irradiation and sunlight ...

207

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics was used to characterize the pulse rise ...

2000-01-01

208

Quick separation of fission product molybdenum and gamma-rays of Mo-102  

International Nuclear Information System (INIS)

... electrophoresis fission products gamma radiation gamma spectra half-life

209

Probing of the Higgs-fermion coupling at. gamma. gamma. -colliders  

Energy Technology Data Exchange (ETDEWEB)

Three possibilities to observe the Higgs-top interaction at future {gamma}{gamma}-colliders are discussed: (a) associated Higss production via the {gamma}{gamma}{yields}tanti tH reaction, (b) Higgs obliged radiative correction to the {gamma}{gamma}{yields}tanti t channel, (c) Higgs resonance production via {gamma}{gamma}{yields}H{yields}ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at {gamma}{gamma}-colliders. (orig.).

1992-11-01

210

Probing of the Higgs-fermion coupling at #gamma##gamma#-colliders  

International Nuclear Information System (INIS)

Three possibilities to observe the Higgs-top interaction at future #gamma##gamma#-colliders are discussed: a) associated Higss production via the #gamma##gamma##->#tanti tH reaction, b) Higgs obliged radiative correction to the #gamma##gamma##->#tanti t channel, c) Higgs resonance production via #gamma##gamma##->#H#->#ZZ. The results obtained show windows of the Higss mass where the Yukawa interaction of the Higss with the top quark can be studied at #gamma##gamma#-colliders. (orig.).

211

Proceedings of the first meeting on e{gamma}/{gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The first meeting on e{gamma}/{gamma}{gamma} colliders was held on September 28 and 29, 1993, at the National Laboratory for High Energy Physics. After general remarks were delivered, lectures were given on QED in intense laser field, photon linear collider, laser focusing, luminosity distribution in the e{gamma}/{gamma}{gamma} colliders, QCD correction for {gamma}{gamma}{yields}H, radiation correction for e{gamma}/{nu}W process, SUSY particle production at the e{gamma} and {gamma} gamma colliders, formation of e{sup *} in e{gamma} collision, and general remarks on the theory. Discussion was carried out on `Where are we going from here?` In this book, the gists of the lectures are collected. (K.I.).

1994-01-01

212

Recurrent plot analysis of discharge sequences in tracking test of polybutylene polymers  

Energy Technology Data Exchange (ETDEWEB)

Polymers are required to use in radiation environments as insulation materials. However, they often suffer from tracking failure. There is an increasing demand to evaluate radiation effects on dielectric performance. This paper presents a recurrence plot (RP) approach to analyse surface discharge sequences of gamma-ray irradiated polymer materials based on tracking test. Studying the non-linear characteristics of discharge sequences can assist in understanding the underlying mechanism of the discharge process. Discharge sequences of the test are extended to m-dimensional phase space by using the phase space reconstructed method. As test samples, polybutylene terephthalate (PBT) and polybutylene naphthalate (PBN) were irradiated to 100 kGy and then up to 1 MGy with a dosage rate of 10 kGy h{sup -1} by using a {sup 60}Co gamma source. The tracking tests were carried out according to the test method ...

2008-10-07

213

Preparation and characterization of CdS nanoparticles and CdS/polyacrylonitrile nanocomposites by {gamma}-irradiation  

Energy Technology Data Exchange (ETDEWEB)

There has been considerable interest in producing and studying nanoparticle materials because of the effect of size on their structure, physical and chemical structure. Most studied nanoparticle semiconductors belong to the II-VI group, as they are relatively easy to synthesize and are generally prepared as particulates or in thin film form. Among II-VI compounds, CdS is one of the most studied materials. There are different ways to synthesize CdS nanoparticles such as colloidal particles, chemical decomposition, sol-gel, gas evaporation, magnetron sputtering, electrostatic deposition, and etc. {gamma}-irradiation is one of the effective methods for synthesis of nanomaterials. These nonomaterials have been extensively used in the preparation of nanocrystalline metals, metal oxides, and metal-polymer composites. However, The preparation of CdS nanoparticle and CdS/ polyacrylonitrile nanocomposite by {gamma}-irradiation ...

2001-11-15

214

Gamma radiation (Co{sup 60}) effects on active substances and microbe burden of medicinal plants; Avaliacao dos efeitos da radiacao gama (Co{sup 60}) sobre principios ativos e carga microbiana de plantas medicinais  

Energy Technology Data Exchange (ETDEWEB)

In order to evaluate the effects of radioactivity on active vegetal substances, samples of Fennel (Foeniculum vulgare Miller., fructus), Guarana (Paulinia cupana, Kunth, semen), Gingko (gingko biloba, L., folium), and Kawa-Kawa (Piper methysticum G. Forst, rhizoma), were treated with scaling doses (0 to 25 KGy) of gamma radiation (Co{sup 60}). The 'blind test' methodology was used. The active substances from each sample were analysed by qualitative and quantitative methods after radiation. There were no significant differences seen between the control sample (0 KGy) and the irradiated samples. Microbe contamination was significantly reduced, about 10000 CFU/g, with the initial 5 KGy dose. It was concluded that gamma radiation can be used as an alternative procedure to reduce microbiologic contamination in medicinal plants. Before this procedure can be extended to other medicinal plants, more specific ...

2001-04-01

215

Calibration free laser-induced breakdown spectroscopy of oxide materials  

Energy Technology Data Exchange (ETDEWEB)

The quantitative determination of oxide concentration by laser-induced breakdown spectroscopy is relevant in various fields of applications (e.g.: analysis of ores, concrete, slag). Calibration free laser-induced breakdown spectroscopy and the multivariate calibration are among the methods employed for quantitative concentration analysis of complex materials. We measured the intensity of neutral and ionized atomic emission lines of oxide materials by laser-induced breakdown spectroscopy and we modified the calibration free laser-induced breakdown spectroscopy method to increase the accuracy. The concentration of oxides was obtained by using stoichiometric relations. Sample materials were prepared from oxide powder (Fe{sub 2}O{sub 3}, MgO, CaO) by mixing and pressing. The concentration was 9.8-33.3 wt.% Fe{sub 2}O{sub 3}, 7.6-33.3 wt.% MgO and 33.3-81.2 wt.% CaO for different samples. Nd:YAG laser (wavelength 1064 nm, pulse duration {approx} 6 ...

2010-08-15

216

GaP Project: #gamma#p, #gamma#e, #gamma##gamma# colliders physical programs and CompHEP computer system  

International Nuclear Information System (INIS)

The Gamma Physics (GaP) program of physical phenomena investigation is proposed on #gamma#p, #gamma#e and #gamma##gamma# colliders at TeV energies. The program contains specialized software (CompHEP system) created for automation of particle interaction processes calculations in the framework of various gauge models. Preliminary physical results are presented (heavy quark production, W, Z production, supersymmetry etc.), and further software development is suggested. (R.P.) 22 refs., 8 figs., 4 tabs.

217

Neutron cross section measurements using the ORELA: "6"0Ni(n,x), "4"0Ca(n,x), "2"2Ne(n,#gamma#), "1"8"9Os(n,n'), /sup 186,187,188,189/Os(n,x), "1"8"9Os(n,#gamma#), /sup 148,149,150/Sm(n,#gamma#), "1"7"9Ta(n,#gamma#), /sup 86,87,88/Sr(n,x), "4"0Ar(n,x), the stable tellurium isotopes (n,#gamma#) and "2"0"5Tl(n,x). Progress report, September 1, 1984-August 31, 1985  

International Nuclear Information System (INIS)

The research performed during this reporting period (9/1/84 to 8/31/85) resulted in: (1) publication of three papers; (2) presentation of an invited paper to the conference on ''Neutron-Nucleus Collisions: A Probe of Nuclear Structure''; (3) presentation of three contributed papers at APS meetings; and (4) preparation of three manuscripts, two of which are in the process of internal review at the Oak Ridge National Laboratory and are included with this report, and the third is being typed as this report is being written. The publications and papers deal with topics in both nuclear structure and astrophysics. Our efforts to study the systematic behavior of the optical model potential in the energy region just above neutron binding has been made substantially more reliable with the publication of a paper which discusses the accuracy of the methods used to average the measured scattering matrix. In the area of stellar nucleosynthesis, comparison of our model ...

218

Effect of some physical treatments on anti nutritional factors and fatty acids composition of Vicia faba L. seeds  

International Nuclear Information System (INIS)

This study was carried out to evaluate the effects of irradiation (gamma irradiation at dose levels of 0.0, 2.5, 5.0, 10.0 or 20.0 kGy, He-Ne and their combination) on nutritive characteristics of Vicia faba L. seeds (Giza 843). Analyses included levels of anti-nutrients (total phenolic compounds, tannins, phytic acid, trypsin inhibitor and vicine), chemical composition (sugars, crude proteins, fat, dry matter and ash) and fatty acids profile. All treatments caused significant (P<0.05) decreases in the antinutrational factors under investigation. The reduction in the content of tannins and phenolic compounds were more pronounced with He-Ne alone or He-Ne in combination with gamma irradiation. At dose levels 10.0 and 20.0 kGy without or with combination of He-Ne were more efficiency in the reduction of phytic acid content by 24.3, 32.8, 34.5 and 45.5 %, respectively. Also, for trypsin inhibitor activity, the maximum inhibition was observed ...

219

The triaxial motion in Mo isotopes  

Energy Technology Data Exchange (ETDEWEB)

The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of [sup 87]Mo are studied in detail and explained by the evolution of the [gamma]-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N [>=] 47 for the spherical shape of the Mo isotopes. (orig.)

1993-11-22

220

The triaxial motion in Mo isotopes  

International Nuclear Information System (INIS)

The nuclear shapes of transitional Mo isotopes are calculated by means of a model based on the cranking approximation and the Strutinksy method. The recent experimental results of the high-spin spectroscopy and lifetime measurement of "8"7Mo are studied in detail and explained by the evolution of the #gamma#-deformation with the quasiparticle configurations. The shape calculations with the modified-harmonic-oscillator potential give a critical neutron number N #>=# 47 for the spherical shape of the Mo isotopes. (orig.).

221

TSI study of multiactivated SrS phosphors  

International Nuclear Information System (INIS)

Data of thermally stimulated luminescence (TSL) of single (Cu), double (Cu, Mn) and triple (Cu, Mn, Gd) activated SrS phosphors, which throws light on the nature and distribution of deeper traps have been presented. The samples are prepared by Bhawalkar's method and excited by UV 365 nm and #gamma#-rays to study the phenomenon. (author). 8 refs., 2 figs., 1 tab.

222

Study of cosmic ray nuclei detection by an image calorimeter  

Energy Technology Data Exchange (ETDEWEB)

It is shown that a cosmic gamma-ray telescope made of a multilayer silicon tracker and a imaging CsI calorimeter, is capable of identifying cosmic ray nuclei. The telescope charge resolution is estimated around 4% independently of charge. Simulation methods are used to determine the telescope properties for nuclei detection.

1995-09-01

223

Spherical harmonic operator method of solving the transport equation in curvilinear coordinates. Application to #gamma#-theta geometry  

International Nuclear Information System (INIS)

An explicite PN solution of the multi-dimensional homogeneous neutron transport equation is given by expanding the angular flux into a series of geometry-independent spherical harmonics operators. An algorithm is developed for representing the spherical harmonic operators in orthogonal curvilinear coordinates. The general formulae are applied to two-dimensional spherical geometry; detailed P3 formulae are given. (orig.).

224

Solution of Bohr's collective Hamiltonian for transitional odd-mass nuclei  

International Nuclear Information System (INIS)

A numerically feasible method, based on the use of deformed phonons, is developed for the diagonalization of the collective quadrupole Hamiltonian for a system with an odd particle coupled to an anharmonic even core. Examples: the transition from prolate to oblate via #gamma#-unstable shapes and furthermore the hsub(9/2) spectra of the nuclei "1"8"7Ir and "1"9"7Tl. (Auth.).

225

Radiometric measurement of lead-201 and thallium-201 activity in industrial production of thallium chlorides  

International Nuclear Information System (INIS)

The spectrometric methods and equipment for "2"0"1Pb and "2"0"1Tl activity control in the prepared thallium chloride in industrial production are described. Estimation of thallium-201 activity is carried out in accord with the square of summary photopeak caused by #gamma#-quanta at 167 keV energy. Attenuation is paid to spectrometer calibration. 5 refs.; 2 figs.; 2 tabs.

226

RESUME-95: Results of an International Field Test of Mobile Equipment for Emergency Response  

DEFF Research Database (Denmark)

In 1995 the exercise RESUME-95 (Rapid Environmental Surveying Using Mobile Equipment) took place in Finland. Groups from 8 European countries joined the exercise. The methods used were airborne gamma-ray measurements, car-borne measurements and in situ stationary measurements. The results of the measurements are analyses aiming at disclosing similarities and differences between groups and measuring techniques.

1997-01-01

227

Nondestructive determination of airborne lead particulates by the radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Airborne lead particulates collected on a membrane filter were determined by the nondestructive X-ray fluorescence method. The gamma/X radionuclide source "2"4"1Am/Ag and a scintillation detector with a NaI/Tl crystal were used for the excitation and detection, respectively, of L X-rays of Pb. One can say, with reference to the obtained results, that the sensitivity and accuracy of the measurement is more than adequate for monitoring the Pb level in air. (author).

1980-01-01

228

Development and utilization of the inorganic polymer materials for {sup 99}Mo-{sup 99m}Tc and {sup 188}W-{sup 188}Re generator based on (n, gamma) method  

Energy Technology Data Exchange (ETDEWEB)

A molybdenum (Mo) adsorbent called PZC (Poly Zirconium Compound) with high efficiency of Mo adsorption has been developed in order to generate {sup 99m}Tc from {sup 99}Mo produced from natural Mo by (n, gamma) method. The {sup 99m}Tc generator using PZC has cleared mostly the technical subjects. By the results of many experiments, cold and hot test with {sup 99}Mo activity from low level (10{sup 5} Bq) to high level (10{sup 10} Bq), it has been confirmed that the PZC method can be practically applied for the (n, gamma) {sup 99}Mo-{sup 99m}Tc generator. From the reasons that PZC has the ability and many merits such as high adsorption capacity (>250 mg-Mo/g-PZC) of Mo, high elution yield (av. 80%) of {sup 99m}Tc, the low breakthrough (<0.05 kBq-{sup 99m}Mo/MBq-{sup 99m}Tc) of {sup 99}Mo and others, the current (n, fission) {sup 99m}Tc generator utilizing {sup 99}Mo produced from enriched ...

2003-03-01

229

Measurement of "1"0"1Tc Half-Life  

International Nuclear Information System (INIS)

75 mg (NH_4)_6Mo_7O_24 #centre dot# 4H_2O solution was irradiated for 20 min in miniature neutron source reactor (MNSR) and cooled for 12 min. In the conditions of 0.8 mol/L HNO_3, phase ratio 1:1, the solution of "1"0"1Tc sample was extracted twice with #alpha#-benzoin oxime/ethyl acetate phase to remove "1"0"1Mo and a radiochemically pure and carrier-free "1"0"1Tc product was obtained. The half-life of "1"0"1Tc was accurately measured with a HPGe #gamma#-detector by following 306.8 keV #gamma#-ray about 150 min, and processed the data by three methods, R-value method, iterative method and translation method. Five parallel measurments gave a half-life (14.02 #+-# 0.01) min (n=5) for "1"0"1Tc. (authors)

2009-11-01

230

Radon measurements in dwellings using activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

In Sweden there is a demand for a method of measuring radon in dwellings with high accuracy and at a low cost. A method of determining radon concentration (Bq.m/sup -3/) in dwellings has been developed at the Swedish National Testing Institute. A plastic canister containing activated charcoal has been tested in a radon chamber (volume 20 m/sup 3/) to determine the effects of relative humidity, temperature and exposure time. The activated charcoal in the canister adsorbs radon from the air surrounding the canister. The radon concentration is determined by counting the gamma rays from the decay of radon and daughters. The theory and preliminary results from calibrations and field measurements are reported.

1984-01-01

231

MCNP-DSP calculations of the {sup 252}Cf-source-driven noise analysis measurements of highly enriched uranium metal cylinders  

Energy Technology Data Exchange (ETDEWEB)

This paper presents calculations of the {sup 252}Cf-source-driven noise analysis measurements for subcritical highly enriched uranium metal cylinders using the Monte Carlo code MCNP-DSP. This code directly calculates the noise analysis data from the {sup 252}Cf- source-driven noise analysis method for both neutron and gamma ray detectors. Direct calculation of experimental observables by the Monte Carlo method allows for the benchmarking of the calculational model and the cross sections and for determining the bias in the calculation.

1995-07-01

232

LET-dependence of the trapping parameters in TLD-100 determined with a computerised curve fitting method  

International Nuclear Information System (INIS)

With a computerized curve fitting method the trapping parameters of TLD-100 chips were calculated after #alpha#-, #beta#- and #gamma#-irradiation. The absorption of radiation produces an additional glow peak at 250 deg C, and the dominant one arises at 280 deg C. After the analysis of the glow curves only a little LET-dependence of the trap depths and that of the half widths was detected. The charge densities after irradiation before heating of the taps responsible for the high temperature glow peaks (T>240 deg C) show a LET-dependence. (author).

1985-10-22

233

Estimation of X-rays dose in the crystals of final thickness  

International Nuclear Information System (INIS)

A calculation method of the X-ray radiation dose (energy of gamma- radiation remains in the range of energies where the mechanism of photoelectric absorption is the prevailing one) absorbed in the absorbers of final thickness is suggested. Calculations of resorption of secondary radiation (characteristic fluorescences) in the substance and kinetic energy of photoelectrons caused by this resorption (it would be enough to consider one or two hard series) are presented. Calculation of the spectrum of photoelectron energy yield in TeInSe_2 monocrystal for 0.1-0.5 A range of X-ray radiation is conducted by the developed methods.

234

Analysis of thermoluminescence glow curves of minerals sphene and epidote for radiation damage studies  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence (TL) properties of sphene and epidote are of interest in studies related to their radiation damage. Natural and artificially induced TL of these minerals has, therefore, been investigated. Both minerals exhibit complex glow curves with several overlapping peaks. The Tsub(m) -Tsub(STOP) thermal cleaning procedure has revealed three peaks in the ..gamma.. ray induced glow curve of each mineral. That these peaks obey second order kinetics was indicated by the continuously slanting structure of the Tsub(m)-Tsub(STOP) curve. The TL parameters E and s have been calculated using (i) the initial rise method, and (ii) the glow-peak shape method. In general, the values of E calculated by the first method are found to be higher than those from the second. The TL curve-fitting method is also applied in order to calculate these parameters and to serve as a cross-check on the ...

1986-01-01

236

Semihard production of tensor mesons in #gamma##gamma#-collisions and the perturbative Odderon  

International Nuclear Information System (INIS)

The cross sections of neutral tensor mesons T=a_2, f, f', ... production in the exclusive #gamma##gamma##->#TT' or semiexclusive #gamma##gamma##->#TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV"2 are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future #gamma##gamma#-colliders is discussed too. (orig.).

237

Composite vector leptoquarks in e"+e-, #gamma#e, and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study the signals for composite vector leptoquarks in e"+e- colliders (CERN e"+e- collider LEP II, Next Linear Collider, and CERN Linear Collider) through their effects on the production of jet pairs, as well as their single and pair productions. We also analyze their production in #gamma#e and #gamma##gamma# collisions.

238

Neutron beam experiments using nuclear research reactors: honoring the retirement of professor Bernard W. Wehring -II. 4. Accurate Characterization of the Shape of the HPGe Detector Peak Efficiency Curve for Application in PGNAA  

International Nuclear Information System (INIS)

In various situations, measurements in prompt gamma neutron activation analysis (PGNAA) are performed to determine the amount of an elemental impurity relative to that of a major constituent of the matrix. An example of this is the measurement of hydrogen concentration in a metallic matrix. In all such cases, a major contributor to the uncertainty in the measurement is the uncertainty in the ratio of the high-purity germanium (HPGe) detector full-energy peak efficiency for the gamma-ray lines of interest (i.e., impurity and matrix gammas). Usually, the ratio is derived from the relative peak efficiency curve, which is determined using isotopic standards that emit multiple gamma ray lines (e.g., "1"5"2Eu) in the energy range <3000 keV, or using prompt gamma radionuclides (e.g., "1"4N, "3"5Cl) in the energy range >3000 keV. In either case, the uncertainty in the ratio of the ...

2001-06-17

239

Plasma Diagnostics in the Optical and X-ray regions on the Plasma Focus device PF-4 (Installation TYULPAN)  

International Nuclear Information System (INIS)

The results of experiments received on the plasma focus (PF) device with energy stored equal 4 kJ are represented. Photos of the current plasma sheath (CPS), pre-pinch, sphere-like plasma formations are produced with help of the electron-optical converter contained a gated micro-channel plate (MCP) and the CCD-camera imaging system in the visible region. The redial velocity of the CPS is about 107 cm/s. Neon plasma electron density measured with help of the interferograms in the visible region and the spectra in the soft X-ray region is equals to 3?1018 cm-3. Electron temperature is equal to about 200 eV. Discharge integral photos were obtained with help of the soft X-ray pinhole camera. Pictures with 2 ?s resolution of the plasma luminescence above PF anode region were made by CCD-camera.

2006-01-01

240

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

Energy Technology Data Exchange (ETDEWEB)

Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...

1998-02-01

241

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

International Nuclear Information System (INIS)

Real-time neutron radiography has been used to study the dynamic behavior of two-phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam-water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two-phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 MW TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...

1999-11-03

242

Vapor fraction measurements in a steam-water tube at up to 15 bar using neutron radiography techniques  

International Nuclear Information System (INIS)

Real time neutron radiography has been used to study the dynamic behavior of two phase flow and measure the time averaged vapor fraction in a heated metal tube containing boiling steam water operating at up to 15 bar pressure. The neutron radiographic technique is non-intrusive and requires no special transparent window region. This is the first time this technique has been used in an electrically heated pressurized flow loop. This unique experimental method offers the opportunity to observe and record on videotape, flow patterns and transient behavior of two phase flow inside opaque containers without disturbing the environment. In this study the test sections consisted of stainless steel tubes with a 1.27 cm outer diameter and wall thicknesses of 0.084 cm and 0.124 cm. The experiments were carried out at the Pennsylvania State University 1 megawatt TRIGA reactor facility utilizing a Precise Optics neutron radiography camera. The inlet water ...

1998-03-16

243

Radiation dosimetry of "1"1"1In-oxinate labelled leucocytes  

International Nuclear Information System (INIS)

The patients studied were referred for routine abscess localization with indium-111 labelled autologous leukocytes. One series (n=15) was studied at 1 day after reinjection of labelled cells and a second series (n=9) was studied between 4 hours and 4 days after reinjection of labelled cells. The leukocytes were isolated by a gravity sedimentation method and labelled with In-111 oxinate according to Roevekamp and co-workers. The labelled cell suspension administered to the patient contained between 11 and 15 MegaBq (300-400 microCi). The indium-111 concentration in the liver and spleen was quantitated using a scintillation camera and an on-line computer system. Phantom studies were carried out to obtain conversion factors from geometric mean counts to MegaBq of activity for both liver and spleen. Once determined, the amount of activity in liver and spleen was corrected for physical decay of In-111 and expressed as a percentage of the ...

1982-06-25

244

Anode length optimization in a modified plasma focus device for optimal x-ray yields  

International Nuclear Information System (INIS)

The effect of anode length and operating gas pressure on the x-ray emission from a nitrogen-filling modified plasma focus device has been investigated. The time-resolved investigation of x ray was carried out by using a five-channel photodiode x-ray spectrometer. The maximum x-ray yield is seen to increase with the increase in the anode length from 110 to 125 mm. Further increase in the anode length to 130 mm causes the x-ray yields to decrease. The highest x-ray yield of 4.5 J into 4#pi# sr was found for 125 mm anode length, which is 0.2% of the input energy. The average x-ray photon energy was estimated by using half-value thickness method and found to be 8.4 keV. The electron temperature of the plasma was estimated to be around 3 keV by x-ray intensity ratio method. The space-resolved x-ray-emitting zones for all the anodes were captured by a pinhole-based x-ray imaging camera and the images were scanned for different ...

2006-01-01

245

Spatial distribution of IGC-30 Ge-detector's efficiency  

International Nuclear Information System (INIS)

The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).

1993-12-02

246

Numerical solutions of high-frequency perturbations in Bianchi type IX models  

International Nuclear Information System (INIS)

The problem in perturbation theory in general relativity is finding a natural gauge which simplifies the equations considerably. We solved the first and second order perturbation equations in the ''Lorentz gauge'' using the two-timing method. The equations were deduced from the equations of Einstein in the presence of a matter energy-momentum tensor of a perfect fluid with equation of state p = (#gamma#-1) rho. It is found that the 0--0 component of the first order equations together with the gauge conditions are consistent with the Bianchi type V model, without axial symmetry. It represents a ''ground state'' situation of the Bianchi type IX model (Mixmaster model.) The second order equations, describing the reaction back of the gravitational waves on the slowly varying background, give rise to rotation and will disturb the isotropization mechanism. The numerical solutions show all the features which are expected to appear. Moreover, it is ...

247

Measurement of cumulative and independent yields of products from fission of sup(242m)Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

Mass and charge distributions of products from fission of sup(242m)Am induced by thermal neutrons have been investigated by means of the semiconductor spectrometry of ..gamma.. radiation from a mixture of non-separated fragment nuclei. Specimens of the fissible material have been irradiated in the vertical experimental channel of the research reactor then the measurements have been performed with calibrated semiconductor detectors. Three experiments with substantially different irradiation times have been performed to expand the nomenclature of the investigated fission products. The spectra of ..gamma.. radiation from the mixture of fission products, and time dependences of the counting rates at the total absorption peaks have been handled with computers. The obtained yields are compared with data of previous investigations performed with different experimental methods, as well as with the calculated one.

1985-03-01

248

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

249

Fuel element powers, STVU masses, and burnups from gamma-scanning data: Preliminary analysis of irradiated ORR (Oak Ridge Research Reactor) LEU fuel elements  

Energy Technology Data Exchange (ETDEWEB)

Fuel elements used in the ORR whole-core LEU fuel demonstration have been gamma-scanned to determine axial distributions of UZLa and TXCs fission product activities. This data has been analyzed to determine cycle-averaged fuel element powers, residual STVU masses, and burnups of discharged fuel elements. Methods used to analyze the data are discussed and results are presented for the LEU fuel elements. Measured and calculates fuel element powers agree to within 5%, residual STVU masses to within 2%, and burnups to within 3%. These results are somewhat preliminary and await improved burnup calculations and independent calibration data to be based on the destructive analyses of a number of irradiated fuel elements. 4 refs., 7 figs., 3 tabs.

1988-01-01

250

Effect of some chemicals on the radiation-induced lipid peroxidation  

International Nuclear Information System (INIS)

The effect of exposure to gamma rays on LPO contents in liver, spleen and kidney of mice and the anti-lipid-peroxidation of preparations of chinonin, tannic acid and squalene were reported. All these preparations were given by intragastric perfusion. For LPO, a modified method of TBA spectrophotometry was used for determination. The results show that LPO contents in tissues increased 72 h after whole-body exposure of mice to gamma rays, that in range of 0-4 Gy, there was a linear relationship between radiation doses and LPO contents, and that all three preparations were effective in reduction of the LPO content in liver, spleen and kidney of mice, with chinonin (at dose of 0.35 mg/mouse#centre dot#day) being more effective than tannic acid (at dose of 15 mg/mouse#centre dot#day) and squalene (at dose of 0.6 mg/mouse#centre dot#day).

251

Computational experience with an explicit difference scheme for a one phase Stefan problem  

Science.gov (United States)

The results of a computational scheme of Rose (a method for calculating solutions of parabolic equations with free boundary, Math. Comp., 14: 249-256(1960)) are compared with the known analytic solution of a single-phase Stefan problem with constant boundary temperature. Rose's scheme was implemented in FORTRAN on a DEC PDP-10. Computations were performed for Stefan numbers St = 0.01, 0.1, 1, 10, and 100. Three relative mesh sizes (..gamma.. = DT/(DX)/sup 2/ = 1/2, 1/6, and 1/25) were used. For each St, the relative mesh size had very little effect on accuracy. However, taking ..gamma.. = 1/25 resulted in dramatically increased computing time. The relative errors of temperature were large near the phase change front. 11 figures, 5 tables.

1980-07-01

252

Association of the polymorphism of the CAG repeat in the mitochondrial DNA polymerase gamma gene (POLG) with testicular germ-cell cancer  

British Library Electronic Table of Contents (United Kingdom)

Background: A possible association between the polymorphic CAG repeat in the DNA polymerase gamma (POLG) gene and the risk of testicular germ-cell tumours (TGCT) was investigated in this study. The hypothesis was prompted by an earlier preliminary study proposing an association of the absence of the common 10-CAG-long POLG allele with testicular cancer as well as previously reported in some European populations' association with male subfertility, which is a condition carrying an increased risk of TGCT. Patients and methods: The number of CAG repeats in both POLG alleles was established in 243 patients with TGCT and in 869 controls by the analysis of the genomic DNA fragment. Results: A significantly higher proportion of men homozygous allele of other than the common 10 CAG repeats was fou...

2008-01-01

253

Study on the angular. gamma gamma. -correlations for nuclei of Sr even-even isotopes  

Energy Technology Data Exchange (ETDEWEB)

The angular ..gamma gamma..-correlations for nuclei of Sr even-even isotopes with A=82, 84, 86, 88 were measured. Multipole structurs of ..gamma..-transtion series and th coefficients multipole mixing were determined.

1984-05-01

254

Study on the angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes  

International Nuclear Information System (INIS)

The angular #gamma##gamma#-correlations for nuclei of Sr even-even isotopes with a=8 82, 84, 86, 88 were measured. Multipole structurs of #gamma#-transtion series and th coefficients multipole mixing were determined.

1983-04-01

255

Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences  

Science.gov (United States)

The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)

1973-08-01

256

Accelerator aspects of #gamma#-#gamma# colliders  

International Nuclear Information System (INIS)

There are several on-going projects of e"+e"- colliders. If they are constructed, we can convert them into photon-photon (#gamma#-#gamma#) colliders by converting electron beams into #gamma# beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

257

Design of a new serotonin receptor 5-HT_1_A imaging agent based on "9"9"mTc  

International Nuclear Information System (INIS)

Serotonin is one of the neurotransmitters found in the brain and mediates brain functions. It is very well known that serotonin related brain abnormalities are exerted mainly via serotonin receptors in a similar manner to other neurotransmitters found in the brain. Recently, it has also been found that serotonin is involved in Alzheimer's disease either directly or indirectly by its actions on serotonergic neurons. To understand and treat the diseases caused by abnormalities in the serotonergic system in the brain, it is certain that its mechanism of function has to be well investigated. So far several 5-HT receptors and receptor subtypes have been well characterized. Moreover, serotonin agonists and antagonists acting on specific receptors are chemically synthesized and are now available for the prevention or treatment of serotonergic related diseases. In recent years, a great demand for developing neuroimaging agents has emerged for the diagnosis of abnormal brain functions in the ...

2004-07-01

258

Excited leptons and quarks at. gamma. gamma. /. gamma. e colliders  

Energy Technology Data Exchange (ETDEWEB)

We discuss the search of excited leptons and quarks with spin 1/2 at {gamma}{gamma} and at {gamma}e colliders. We show that {gamma}{gamma} colliders have important advantages for the observation of excited leptons and quarks in comparison with ee, ep, and pp colliders discussed in previous papers. These collisions give a simple test for the chirality of the l{sup *}l{gamma} transition. The anomalous magnetic moment of excited leptons can be observed when its value is not too small. (orig.).

1992-02-06

259

Real-time neutron radiography system performance - Measurements and methods  

Energy Technology Data Exchange (ETDEWEB)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, ...

1988-09-01

260

Real-time neutron radiography system performance - Measurements and methods  

International Nuclear Information System (INIS)

The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time system, including both the neutron beam and the electronic ...

1988-01-01

261

Luminescence characteristics for the detection of radiation treatment of shellfish by using isolated minerals  

International Nuclear Information System (INIS)

Seven types of shellfish were irradiated by gamma ray at doses of 0, 3 and 6 kGy. Pulse photo-stimulated luminescence (PPSL) and thermoluminescence (TL) methods were employed to detect the radiation treatment. The screening of irradiation was carried out by the PPSL method followed by identification using the TL technique. Most of the irradiated shellfish were screened out correctly and only a few showed photon counts a bit higher than the lower threshold value by much lower than the upper threshold value. The TL method was employed using minerals isolated from all the control and irradiated shellfish samples by density gradient treatment. Three parameters, integrated intensities of first glow curves (TL1), ratios of first to that of second glow curves (TL1/TL2), and the shapes of maxima of first glow curves, were utilized for the identification of gamma ray treatment of shellfish. ...

262

Determination of americium in plutonium based nuclear fuel materials: An assessment of different methodologies  

International Nuclear Information System (INIS)

Determination of americium (Am) is one of the requirements of chemical quality assurance of plutonium (Pu) bearing fuel materials. Though many methods are published for determining Am at picogram to femtogram levels in environmental and biological matrices, yet a few of them are used routinely for Pu based nuclear fuel samples. This paper gives a brief summary of the different analytical methods available and presents results of our experiments on the determination of Am in Pu bearing fuels using gamma spectroscopy. The methods utilizing gamma emissions from "2"4"1Am and Pu isotopes are fast as they do not involve chemical separation of Pu and Am, do not require an accurate knowledge of the efficiency values of the detector systems and are not dependent on the availability of a radiometric standard for "2"4"1Am. In addition, for aged Pu samples containing large amounts of "2"4"1Am, ...

2010-11-15

263

Calibration methods of plane-parallel ionization chambers used in electron dosimetry; Metodos de calibracao de camaras de ionizacao de placas paralelas para dosimetria de feixes de eletrons  

Energy Technology Data Exchange (ETDEWEB)

The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)

1999-07-01

264

Assay of the uranium and plutonium content in process residues and wastes using the correction for sample self attenuation in segmented gamma scanning system  

International Nuclear Information System (INIS)

A method of the correction for sample self attenuation used in segmented gamma scanner (SGS) is described. The method of calibration for assaying the uranium and plutonium contents of each category of heterogeneous process residues and wastes in nuclear facilities is studied. The effect of variable measurement parameter on measurement results is also studied. The measurement results of SGS assay is compared with that of the destructive assay (DA), which is aimed at evaluating SGS method for assaying uranium and plutonium content in process residues and wastes. The deviation of two assay results is 3.6%. The SGS assay results and DA assay results both are coincided well in error limits. Four category of heterogeneous process residues and wastes in nuclear facilities have assayed successfully in physical inventory. The uncertainty of measurement results for uranium and plutonium content in process ...

1998-09-01

265

The measurement of the fission product ratios, {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuel by gamma scanning method  

Energy Technology Data Exchange (ETDEWEB)

We obtained the ratios of {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of {sup 134}Cs and {sup 154}Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive {sup 134}Cs/{sup 137}Cs and {sup 154}Eu/{sup 137}Cs. (author). 4 refs., 27 tabs., 28 figs.

1997-10-01

266

The measurement of the fission product ratios, "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuel by gamma scanning method  

International Nuclear Information System (INIS)

We obtained the ratios of "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs in spent PWR fuels with gamma scanning equipment of irradiated material examination facility. The fuel segments, of which the burn-up is about 40 GWD/MTU and its cooling time is 8.4 years, are prepared in Post Irradiated Examination Facility and transported to IMEF. By considering of multi-peaks of "1"3"4Cs and "1"5"4Eu, we obtained the relative efficiency of the gamma scanning system as a function of energy. And finally we obtained the number ratios of radioactive nuclides in 72 fuel pellets, radioactive "1"3"4Cs/"1"3"7Cs and "1"5"4Eu/"1"3"7Cs. (author). 4 refs., 27 tabs., 28 figs.

1988-09-18

267

The H-test probability distribution revisited: Improved sensitivity  

CERN Document Server

Aims: To provide a significantly improved probability distribution for the H-test for periodicity in X-ray and $\\gamma$-ray arrival times, which is already extensively used by the $\\gamma$-ray pulsar community. Also, to obtain an analytical probability distribution for stacked test statistics in the case of a search for pulsed emission from an ensemble of pulsars where the significance per pulsar is relatively low, making individual detections insignificant on their own. This information is timely given the recent rapid discovery of new pulsars with the Fermi-LAT t $\\gamma$-ray telescope. Methods: Approximately $10^{14}$ realisations of the H-statistic ($H$) for random (white) noise is calculated from a random number generator for which the repitition cycle is $\\gg 10^{14}$. From these numbers the probability distribution $P(>H)$ is calculated. Results: The distribution of $H$ is is found to be ...

2010-01-01

268

Non-Destructive Testing of Bus-Bar Joints Powering LHC Superconducting Magnets, by Using Gamma Sources  

CERN Document Server

The main LHC superconducting magnets (dipoles and quadrupoles) use Rutherford type cables, stabilized electrically and thermally with copper profiles. The portions of cables are connected to each other by a soft soldering technique (Sn96Ag4) with an overlapping length corresponding to one pitch of the superconducting strands. The splice constitutes a "composite" structure with the interchanging layers of Sn96Ag4 and NbTi superconductor, located inside a Cu cage. In order to ensure a high level of reliability (failure probability not exceeding 10-8) for some 10000 connections in the LHC, a non-destructive technique to check the quantity of solder in the joint is foreseen. The technique is based on a gamma ray source (241Am) and the detection is position-sensitive in the transmission mode. Scintillating detectors of gamma rays are used and their accumulated length corresponds to the length of the radioactive source (120 mm). The ...

2004-01-01

269

Evaluation of fungal burden of medicinal plants submitted to gamma radiation process after 30 days  

International Nuclear Information System (INIS)

Forty samples of medicinal plants (Peumus boldus, Camellia sinensis, Maytenus ilicifolia and Cassia angustifolia), purchased from pharmacies and street market in the five cities of Sao Paulo State, were irradiated using a "6"0Co gamma ray source (Gammacell) with a dose of 10.0 kGy, delivered at dose rate of 3.0 kGy/h. Nonirradiated samples were used as controls of fungal isolates. For fungal counts and identification in medicinal plants a serial dilutions from 10"-"1 to 10"-"6 of the samples were seeded in duplicates and plated using the method in Dichloran 18% Glycerol Agar (DG 18) and were counted after five days at 25 deg C. Mycological analysis of control samples revealed the presence of genera Aspergillus and Penicillium, which are known as toxigenic fungi. The process of gamma radiation was effective in reducing the number of colony forming units (cfu/g) in all irradiated samples of medicinal plants after 30 days, ...

270

Wildlife Monitoring Program Plan - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Wildlife Monitoring System Schematic .......................... 40 ...... sentinel species - healthy fish are placed in an environment of water (where they arc not .... The way ir! which data for the fnre mdor study groups will be gathered tor managciacilt ...... Earth Resources Aircraft Program (ERAP) Camera ...

271

Toward Dietary Assessment via Mobile Phone Video Cameras  

UK PubMed Central (United Kingdom)

Reliable dietary assessment is a challenging yet essential task for determining general health. Existing efforts are manual, require considerable effort, and are prone to underestimation and misrepresentation...Full Text Available

2010-01-01

272

Simple device for scanning image  

CERN Document Server

The simple device for scanning image is described. It has much in common with usual TV camera, with an electron beam replaced by an optical one. After the general description of the device, we present a simple experimental illustration.

2002-01-01

273

Gendered Technoculture: Sex, Lies, Videotape & Cyberspace  

Science.gov (United States)

What happens in the matrix of gender, technology, representation, and culture? This class will explore the theoretical issues raised within this matrix. We will also make sense of the theories through practical experiences with technologies like computers and cameras.

2004-02-01

274

Camera for coherent diffractive imaging and holography with a soft-x-ray free-electron laser  

International Nuclear Information System (INIS)

We describe a camera to record coherent scattering patterns with a soft-x-ray free-electron laser (FEL). The camera consists of a laterally graded multilayer mirror, which reflects the diffraction pattern onto a CCD detector. The mirror acts as a bandpass filter for both the wavelength and the angle, which isolates the desired scattering pattern from nonsample scattering or incoherent emission from the sample. The mirror also solves the particular problem of the extreme intensity of the FEL pulses, which are focused to greater than 10"1"4 W/cm"2. The strong undiffracted pulse passes through a hole in the mirror and propagates onto a beam dump at a distance behind the instrument rather than interacting with a beam stop placed near the CCD. The camera concept is extendable for the full range of the fundamental wavelength of the free electron laser in Hamburg (FLASH) FEL (i.e., between 6 and 60 nm) and into the water window. ...

2008-04-01

275

32 CFR 813.4 - Combat camera operations.  

Science.gov (United States)

...COMCAM forces document Air Force and air component activities...supported unified command or joint task force commander, through the...Force COMCAM forces in a joint environment. If an...share of Unified Command headquarters COMCAM and visual...

2010-07-01

276

Application of a gamma spectroscopy system to the measurement of neutron cross sections necessary to the development of nuclear energy; Mise au point d'un systeme de spectroscopie pour mesurer des sections efficaces neutroniques applicables a un possible developpement du nucleaire comme source d'energie  

Energy Technology Data Exchange (ETDEWEB)

This work concerns the development of nuclear energy and nuclear waste management in particular. Two parts of this study can be distinguished. In the first part (theoretical), a thorium-plutonium fuel based on MOX and dedicated for PWR was investigated in order to transmute plutonium in a potentially low waste fuel cycle. It was shown that this type of fuel is not regenerative but could be used for a transition to the industrial thorium fuel cycle without building new reactors. Thanks to moderated neutron spectra and high loaded actinide mass in the core, U-233 is quickly created ({approx}300 kg/y) for a loss of about {approx}1200 kg of fissile plutonium. In the second part (experimental), we have developed and built a new reaction chamber to measure neutron cross sections of actinides by alpha-gamma spectroscopy. This experimental device (in principle transportable) was commissioned in the high flux reactor of ILL Grenoble. Neutron flux was measured by ...

2002-09-01

277

Corrosion studies on selected packaging materials for disposal of high level wastes  

International Nuclear Information System (INIS)

In order to qualify corrosion resistant materials for high level waste (HLW) packagings acting as a long-term barrier in a rock salt repository, the corrosion behaviour of the preselected materials Ti 99.8-Pd, Hastelloy C4 and two unalloyed steels was investigated. The resistance of the materials to general corrosion, local corrosion and stress corrosion cracking was examined under postulated accident conditions in the repository by long-term immersion tests of up to 4 years duration and electrochemical methods. The parameters investigated were different salt brines, temperatures of 90 deg. C, 170 deg. C and 200 deg. C as well as a gamma radiation field of 10"3Gy/h (10"5rad/h). Among the materials studied, Ti 99.8-Pd exhibited the highest corrosion resistance. This material corroded at a very low rate (gamma radiation, and proved to be resistant to local corrosion and stress corrosion ...

1987-05-01

278

Application of BGO scintillators to absolute measurement of neutron capture cross sections between 0.01 eV and 10 eV  

Energy Technology Data Exchange (ETDEWEB)

Applying a total energy absorption {gamma}-ray detector composed of 12 bricks (5x5 cm{sup 2}, 7.5 cm thick) of Bi{sub 4}Ge{sub 3}O{sub 12}(BGO) scintillators, the absolute measurement of capture cross sections for Au and Sb has been made in an energy region between 0.01 eV and 10 eV using the linac time-of-flight method. Incident thermal neutron flux was absolutely determined by using the BGO detection system with a Sm sample. To extend the neutron flux measurement from the thermal neutron region to higher neutron energy, the {sup 10}B(n, {alpha} {gamma}) reaction was applied. Absolute capture yield for the relevant capture sample was obtained by the saturated capture yield at a large resonance of the sample. Gold was selected to investigate the application of the BGO detection system to the absolute measurement of the capture cross sections, since the {sup 197}Au(n, {gamma}){sup 198}Au reaction cross ...

1997-07-01

279

Preliminary Design of ARIES-Devasthal Faint Object Spectrograph and Camera  

CERN Document Server

We present here the preliminary design of ARIES-Devasthal Faint Object Spectrograph and Camera (ADFOSC), which is a multi-mode instrument for both imaging and spectroscopy. ADFOSC is the first-generation instrument to be mounted at the axial port of the Cassegrain focus on our new 3.6m optical telescope to be installed at Devasthal, Nainital. The main design goals of the instrument are : the instrument will have capability of broad- and narrow-band imaging, low-medium resolution spectroscopy, and imaging polarimetry. The operating wavelength range will be from 360 to 1000 nm and the instrument will have remote-control capability.

2009-01-01

280

Breast imaging with a dedicated PEM  

International Nuclear Information System (INIS)

During the last decade there was a growing interest on the application of Positron Emission Tomography, PET, techniques to Breast Imaging. More recently, preliminary results suggested the use of dedicated devices to Breast Imaging using the same technique, the so-called Positron Emission Mammography cameras, PEM. In this article we review the arguments leading to a dedicated instrument. Based on these arguments we describe the concept of a PEM camera under development within the Crystal Clear Collaboration and the first results of its expected performance in terms of sensitivity and position resolution.

2004-07-11

281

Result analysis on the parameter test of radium specific activity calculation in the tailing of uranium mine No. 794  

International Nuclear Information System (INIS)

This paper first introduces the calculating method of radium specific activity to determine the radon emanation rate of tailing of uranium mine No. 794, the method needs two parameters: radon emanation coefficient and radon diffusion coefficient. According to the measured results of parameters and the contrast between radium specific activity of indoor chemical analysis of field sample and field gamma-ray spectra, the authors discuss the variation rules and characteristics of radon emanation coefficient and radon diffusion coefficient, and the best climate and seasons for measuring these parameters in northern China, and finally summarize the characteristics of this method through analyzing measured results. (authors)

2006-09-01

282

Monte Carlo optimization technique applied to "2"3"8Pu production in FFTF [Fast Flux Test Facility  

International Nuclear Information System (INIS)

An accurate neutronics calculation of a local thermal environment within a fast reactor presents a major challenge. A method was previously described that used Monte Carlo techniques within a macrocell to make accurate and reasonably efficient design calculations for such an environment. This method is now being further optimized for the calculation of "2"3"8Pu production in the Fast Flux Test Facility (FFTF). Here, it is not only important to determine the "2"3"8Pu production from neutron capture in "2"3"7Np, but also to calculate the production of the contamination isotope "2"3"6Pu from high-energy (n,2n) and (#gamma#,n) reactions. The power of the Monte Carlo method to automatically include geometry and energy self-shielding is retained by optimization using fission neutron source biasing in both space and energy.

1989-11-26

283

Measurement of the total photoabsorption cross section on a proton in the energy range 600?1500 MeV at the GRAAL  

British Library Electronic Table of Contents (United Kingdom)

The total photoabsorption cross section on a free proton was measured at the GRAAL facility in the energy range E ? = 600?1500 MeV. The large-aperture LAGRAN?E detector and a liquid hydrogen target were used in the experiment performed with a back-scattered Compton gamma beam. To improve the accuracy, two alternative methods were employed. First, a subtraction method of using empty-target measurements allowed the cross section ? tot to be evaluated directly because of a low level of the electromagnetic background. Second, an algorithm for evaluating ? tot on the basis of summing the dominating partial cross sections was developed. Experimental results obtained for ? tot by the two methods are compared with existing data.

2008-01-01

284

Cluster models of light nuclei and the method of hyperspherical harmonics: Successes and challenges  

International Nuclear Information System (INIS)

Hyperspherical-harmonics method to investigate the lightest nuclei having three-cluster structure is discussed together with recent experiments. Properties of bound states and methods to explore three-body continuum are presented. The challenges created by large neutron excess and halo phenomena are highlighted. Astrophysical aspects of the "7Li + n "#-># "8Li + #gamma# reaction and the solar-boron-neutrinos problem are analyzed. Three-cluster structure of highly excited states in "8Be is shown to be responsible for extreme isospin mixing. Progress in studies of "6He- and "1"1Li-induced inclusive and exclusive nuclear reactions is demonstrated, providing information on the nature of continuum structures of Borromean nuclei.

2009-08-01

285

Andreev reflection spectroscopy of MgB{sub 2} in the vortex state  

Energy Technology Data Exchange (ETDEWEB)

Spectroscopy based on the Andreev reflection (AR) process at the interface between the normal metal tip and the superconductor has become one of the very successful methods for studies in novel exotic superconductors. The method is capable to address the size, symmetry as well as multiplicity of the superconducting order parameter. The method provided one of the first evidences of the two-gap superconductivity in MgB{sub 2} with a detailed temperature dependence of the both gaps. A theory treating the Andreev reflection spectroscopy in the mixed state is missing. We analyse the AR spectra of MgB{sub 2} in the mixed state via modelling the magnetic pair-breaking by the increasing spectral broadening parameter {gamma}. As a result a non-trivial pair breaking effect in the {pi}-band is found.

2004-05-01

286

#sigma#_e_e_#gamma#_#gamma#"t"o"t at e"+e"- colliders  

International Nuclear Information System (INIS)

In this talk I briefly summarize different models for #sigma#_2_#gamma#"t"o"t (e"+e"-#->##gamma##gamma##->#hadrons) and contrast model predictions with the data. I will then discuss the capability of the future e"+e"- and #gamma##gamma# colliders to distinguish between various models and end with an outlook for future work.

2001-07-09

287

Experience and recent developments in nuclear forensics at the Institute of Isotopes  

International Nuclear Information System (INIS)

Full text: Based on experience with nuclear material confiscated in Hungary from illicit trafficking activities in the nineties it has been decided that traditional gamma-spectrometry should be complemented by destructive analytical techniques. The 17/1996 (I. 31.) Korm. Governmental Decree delegated the identification, categorization and characterization tasks to the Institute of Isotopes, Budapest. Routine gamma-spectrometric methods have been further developed aiming at the i) age (production date) determination of seized samples and complete (nondismountable) uranium-bearing items (such as fresh fuel bundles and fission chambers) by HRGS technique, ii) improvement of measurement accuracy and reliability. Starting in 2005 mass spectrometry (ICP-SFMS) and scanning electron microscopy have been implemented to characterize nuclear samples in more detail and to analyze environmental samples both for isotopic and elemental ...

288

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. The method can be employed especially ...

289

Gamma-gamma collider based on Compton back-scattering  

International Nuclear Information System (INIS)

A #gamma##gamma# collider would extend and complement the physics capability of a linear collider; e.g. it would be suitable for direct measurement of the partial decay width of a Higgs boson into two gamma quanta. This paper discusses choice of laser parameters, luminosity optimization, electron and laser parameters for a gamma- gamma collider as a second interaction region for the Next Linear Collider, laser path, and the lasers. It is concluded that a gamma- gamma collider is technically feasible; however it will require a significant investment in preparatory R ampersand D.

1996-08-25

290

Chargino production at high energy {gamma}{gamma} colliders with polarized beams  

Energy Technology Data Exchange (ETDEWEB)

We investigate the chargino production process {gamma}{gamma} {yields} (W-tilde){sup +}(W-tilde){sup -} at high energy {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy {gamma} beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background {gamma}{gamma} {yields} W{sup +}W{sup -}. (author).

1995-05-01

291

Chargino production at high energy #gamma##gamma# colliders with polarized beams  

International Nuclear Information System (INIS)

We investigate the chargino production process #gamma##gamma# #-># (W-tilde)"+(W-tilde)"- at high energy #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). Here the high energy #gamma# beams are obtained by the backward Compton scattering of the laser flush by the electron in the basic linear TeV ee colliders. We consider the polarization of the laser photons as well as the electron beams. Appropriate beam polarization could be effective to enhance the cross section to for us extract the signal from the dominant background #gamma##gamma# #-># W"+W"-. (author).

1995-05-01

292

Computer vision algorithms in DNA ploidy image analysis  

Science.gov (United States)

The high incidence and mortality rates of prostate cancer have stimulated research for prevention, early diagnosis and appropriate treatment. DNA ploidy status of tumour cells is an important parameter with diagnostic and prognostic significance. In the current study, DNA ploidy analysis was performed using image cytometry technique and digital image processing and analysis. Tissue samples from prostate patients were stained using the Feulgen method. Images were acquired using a digital imaging microscopy system consisting of an Olympus BX-50 microscope equipped with a color CCD camera. Segmentation of such images is not a trivial problem because of the uneven background, intensity variations within the nuclei and cell clustering. In this study specific algorithms were developed in Matlab based on the most prominent image segmentation approaches that emanate from the field of Mathematical Morphology, focusing on region-based watershed ...

2006-03-01

293

gamma. /sub 5/ in dimensional regularization  

Energy Technology Data Exchange (ETDEWEB)

By generalizing the algebra satisfied by the ..gamma../sub 5/ matrix, it is possible to give an extension of ..gamma../sub 5/ to d dimensions. We discuss the connection of this scheme to others.

1985-02-07

294

Radioprotection through cytokineliberation under N-actylcysteine; Radioprotektion durch Zytokinfreisetzung unter N-Acetylcystein  

Energy Technology Data Exchange (ETDEWEB)

Backgrund: Interleukin-1, tumornecrosisfactor-{alpha} and interferon-{gamma} endogenously provide protection of the hematopoietic system against radiation. Thiols have already been used successfully as radioprotective agents. In this study the effect von N-acetylcysteine (NAC) on the release of interleukin-1{alpha} and {beta} (IL-1), interleukin-2 (IL-2), interferon-{gamma} (IFN-{gamma}) and tumornecrosisfactor-{alpha} (TNF-{alpha}) was assessed in an in vitro assay. Patients and Methods: Whole blood samples from 8 healthy volunteers were stimulated with 7.5 {mu}m/ml PHA. NAC was added at concentrations of 0.6, 6, 12 and 24 mmol/l. Subsequently the samples were irradiated with a dose of 18 Gy according to preceding validation experiments. Results: IL-1{alpha}, IL-1{beta} and IL-2: In comparison to simulation and radiation alone the addition of 0.6 and 6 mmol/l with IL-2 also 12 mmol/l, NAC resulted in a ...

1996-02-01

295

The study of anemia in fowl spirochetosis using radioactive iron  

International Nuclear Information System (INIS)

Radioactive iron is used to follow up some haematologic indices in birds infected with irradiated spirochetes of the Borrelia anderina species. Use is made of a total of 90 cockerels, aged two months, divided into three groups: 1st group - cockerels inoculated with spirochetes that had been gamma-irradiated at the rate of 40000 R; 2nd group - cockerels inoculated with untreated spirochetes; and 3rd group - normal cockerels. The infective material consisted of strain Rouen spirochetes of the Pamoukchii serotype. Radiometric studies were also carried out for establishing to what extent radioactive iron is incorporated in the erythrocytes and is deposited in the liver, spleen, and marrow of the investigated birds. Classical methods of investigation were employed to determine the erythrocyte, leukocyte, and thrombocyte counts, the haemoglobin content (after Sahli) as well as the erythrocyte pack after the method of Todorov. It ...

296

Reconstruction of the activity of point sources for the accurate characterization of nuclear waste drums by segmented gamma scanning  

International Nuclear Information System (INIS)

This work improves the reliability and accuracy in the reconstruction of the total isotope activity content in heterogeneous nuclear waste drums containing point sources. The method is based on #chi#"2-fits of the angular dependent count rate distribution measured during a drum rotation in segmented gamma scanning. A new description of the analytical calculation of the angular count rate distribution is introduced based on a more precise model of the collimated detector. The new description is validated and compared to the old description using MCNP5 simulations of angular dependent count rate distributions of Co-60 and Cs-137 point sources. It is shown that the new model describes the angular dependent count rate distribution significantly more accurate compared to the old model. Hence, the reconstruction of the activity is more accurate and the errors are considerably reduced that lead to more reliable results. Furthermore, the results are ...

2011-06-01

297

Evidence of polarisation in the prompt gamma-ray emission from GRB 930131 and GRB 960924  

CERN Document Server

The true nature of the progenitor to GRBs remains elusive; one characteristic that would constrain our understanding of the GRB mechanism considerably is gamma-ray polarimetry measurements of the initial burst flux. We present a method that interprets the prompt GRB flux as it Compton scatters off the Earth's atmosphere, based on detailed modelling of both the Earth's atmosphere and the orbiting detectors. The BATSE mission aboard the \\textit{CGRO} monitored the whole sky in the 20 keV - 1 MeV energy band continuously from April 1991 until June 2000. We present the BATSE Albedo Polarimetry System (BAPS), and show that GRB 930131 and GRB 960924 provide evidence of polarisation in their prompt flux that is consistent with degrees of polarisation of $\\Pi>35$% and $\\Pi>50$% respectively. While the evidence of polarisation is strong, the method is unable to strongly constrain the degree of polarisation beyond a ...

2005-01-01

298

Characterization system for Germanium detectors dedicated to gamma spectroscopy applied to nuclear waste  

International Nuclear Information System (INIS)

CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, ...

2009-06-07

299

Application od scaling technique for estimation of radionuclide inventory in radioactive waste  

International Nuclear Information System (INIS)

Safety studies related to the disposal of low- and intermediate waste indicate that the long term risk is determined by the presence of long-lived nuclides such as "1"4C, "5"9Ni, "6"3Ni, "9"9Tc, "1"2"9I and the transuranium elements. As most of these nuclides are difficult to measure, the correlation between these critical nuclides and some other easily measurable key nuclides such as "6"0Co and "1"3"7Cs has been investigated for typical waste streams of Paks Nuclear Power Plant (Hungary) and scaling factors have been proposed. An automated gamma-scanning monitor has been purchased and calibrated to determine the gamma-emitting radionuclides. Radiochemical methods have been developed to determine significant difficult-to-measure radionuclides. The radionuclides of interest have been "3H, "1"4C, "9"0Sr, "5"5Fe, "5"9Ni, "9"9Tc, "1"2"9I and TRUs. The measurements taken so far have revealed brand new information and data on ...

1996-09-16

300

Comparison and Physical Interpretation of MCNP and TART Neutron and Gamma Monte Carlo Shielding Calculations for a Heavy-Ion ICF System  

Energy Technology Data Exchange (ETDEWEB)

For heavy-ion beam driven inertial fusion ''liquid-protected'' reactor designs such as HYLIFE-II, a mixture of molten salts made of F{sup 10}, Li{sup -6}, Li{sup 7} and Be{sup 9} (called flibe) allows small chambers and final-focus magnets closer to the target with superconducting coils suffering higher radiation damage, though they can stand only a certain amount of energy deposited before quenching. This work has been primarily focusing on verifying that total energy deposited by fusion neutrons and induced gamma rays remain under such limit values and the final purpose is the optimization of the shielding of the magnetic lens system from the points of view of the geometrical configuration and of the physical nature of the materials adopted. The system is analyzed in terms of six geometrical models going from simplified up to much more realistic representations of a system of 192 beam lines, each focused by six magnets. A 3-D ...

2002-07-01

301

np-nh bands in the N=28 isotones  

CERN Document Server

The existence of n-particle n-hole deformed yrare bands in the N=28 isotones is explored using full pf-shell diagonalizations and the Lanczos Strength Function method. We find different 2p-2h and 4p-4h collective bands that, when allowed to mix, more often disappear. Only the 2p-2h yrare band in Cr-52 and the 4p-4h yrare band in Ni-56 survive, and only in this latter case, due to the reduced density of 2p-2h states, can the band be seen as a gamma-cascade.

2002-01-01

302

Solution of the orthopositronium lifetime puzzle  

CERN Document Server

The intrinsic decay rate of orthopositronium formed in SiO/sub 2/ powder is measured using the direct 2 gamma correction method such that the time dependence of the pick-off annihilation rate is precisely determined. The decay rate of orthopositronium is found to be 7.0396+or-0.0012(stat.)+or-0.0011(sys.)/ mu s/sup -1/, which is consistent with our previous measurements with about twice the accuracy. Results agree well with the O( alpha /sup 2/) QED prediction, and also with a result reported very recently using nanoporous film.

2004-01-01

303

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

304

Monitoring of "1"1"0"mAg in the Daya Bay marine environment  

International Nuclear Information System (INIS)

The author describes the Gamma -spectrum analysis results of "1"1"0"mAg, the method used, and the coincidence correction theory on which the analysis is based. The samples were placed at the upper end of the detector. The monitoring results of "1"1"0"mAg in the surrounding marine area from the beginning of operation of the Daya Bay nuclear power plant are reviewed as well. The results showed that "1"1"0"mAg traces were detected in some marine species. However, the concentrations observed are far below the National Standard limits

1999-09-20

305

Moessbauer diffraction measurements on polycrystalline bcc iron  

Energy Technology Data Exchange (ETDEWEB)

In the early days of Moessbauer spectroscopy, it was demonstrated that coherent scattering of photons emitted by a Moessbauer source can be observed. In spite of the fact that scattering experiments could give information not accessible by the absorption method, they are not widely used. The reasons for this are, on the one hand, experimental difficulties, and on the other hand, the form of the samples, which should be large single crystals in most cases. In this work, we present a Moessbauer diffraction measurement on polycrystalline bcc iron where these problems have been overcome. We demonstrate that using the kinematical theory of gamma-ray diffraction, useful information on the relative orientation of the crystallographic axis to the hyperfine field directions can be subtracted. (orig.)

1994-11-01

306

Electronic structure and properties of boron phosphide and boron arsenide  

International Nuclear Information System (INIS)

The composite wave variational version of the APW (augmented plane wave) method is used to obtain the electronic band structure of the compounds boron phosphide and boron arsenide at the high symmetry points #GAMMA#, X, and L. The tight binding interpolation scheme of Slater and Koster is used to calculate the rest of the band structure. The results show that both these materials are indirect band gap semiconductors. The density of states, and the imaginary part of the dielectric constant is also calculated. The theoretical results are compared with the reported experimental and theoretical data. (author).

307

Age determination of plutonium material in nuclear forensics by thermal ionisation mass spectrometry  

International Nuclear Information System (INIS)

Age is a key parameter when deducing the history of plutonium material, i.e. the plutonium produced in the nuclear reactors. This is of vital importance, when a smuggled plutonium sample has been seized and the origin has to be determined. A methodology is described which allows accurately to determine the age of plutonium material by thermal ionisation mass spectrometry using independent parent/daughter relations. This has been demonstrated for Reference Materials of known ages as well as for real samples. The already established method using gamma spectrometry is compared to this. (orig.)

2000-02-01

308

A new simple multi-well plate-based assay for monocyte differentiation using human monocytic leukemia THP-1 cells.  

Science.gov (United States)

A new simple multi-well plate-based assay to determine monocyte differentiation-inducing activity was developed. It is based on the increase of macrophage adherence after the induction of monocyte differentiation. The assay was conducted using a human monocytic leukemia cell line, THP-1, treated with either 12-O-tetradecanoylphorbol 13-acetate or cytokines, such as tumor necrosis factor-alpha and interferon-gamma. This method is sensitive and easy to perform, especially in case of analyzing a large number of samples. PMID:17920620

2007-09-29

309

A new method for sealing containers with liquid samples for radioactivity measurements  

International Nuclear Information System (INIS)

It is imperative to use a leak-proof container for counting liquid sample to prevent contamination of costly gamma detectors. A sealant that ensures no leak is reported. It is a vinyl adhesive sealant used for household purposes, marketed by Gloucester Co., Inc, Franklin, MA under the trade name of Phenoseal (translucent variety). This sealant was superior to other sealants studied because it cures quickly, peels off easily after counting, and contains no detectable radioactivity. This sealant has been thoroughly tested and successfully employed it in the routine analysis of environmental liquid samples. (author)

2002-08-01

310

Effective use of optimized, high-dose (50 kGy) gamma irradiation for pathogen inactivation of human bone allografts.  

Science.gov (United States)

The safety of tissue allografts has come under increased scrutiny due to recent reports of allograft-associated bacterial and viral infections in tissue recipients. We report that 50 kGy of gamma irradiation, nearly three times the dose currently used, is an effective pathogen inactivation method when used under optimized conditions that minimize damage to the tissue. Cancellous bone dowels treated with a radioprotectant solution and 50 kGy of optimized irradiation had an ultimate compressive strength and modulus of elasticity equal to conventionally irradiated (18 kGy) and non-irradiated control bone grafts. We subjected bone dowels treated with this pathogen inactivation method to an in vitro cytotoxicity test using three different mammalian cell lines and concluded that the treated grafts were not cytotoxic. The log reduction of nine pathogens spiked into radioprotectant-treated bone irradiated to 50 kGy was also tested. ...

2005-05-01

311

Radiogauging to investigate two phase flow. Graduation report  

Energy Technology Data Exchange (ETDEWEB)

New measuring methods are developed and are tested with the small reactor simulator MIDAS (Mini Dodewaard ASsembly). The purpose of this work is to be able to measure accurately as many different properties of the flow as possible in the coming bigger simulator SIDAS (Simulated Dodewaard ASsembly). In SIDAS the flow around a fuel assembly of the Dutch Dodewaard reactor will be simulated. An extensive evaluation of the gamma detection system showed that the detection system could be simplified strongly. The simplified system is used to measure the radial and axial distribution of the void fraction in the core of MIDAS for three different operating conditions. Two new measuring methods have been developed and tested. A method to estimate the probability density of the void fraction in time. Due to the nonlinear relation between transmission and void fraction the determined average value of the void ...

1992-11-12

317

High energy photon-photon collisions  

International Nuclear Information System (INIS)

The collisions of high energy photons produced at an electron-positron collider provide a comprehensive laboratory for testing QCD, electroweak interactions, and extensions of the standard model. The luminosity and energy of the colliding photons produced by backscattering laser beams is expected to be comparable to that of the primary e"+e"- collisions. In this overview, we shall focus on tests of electroweak theory in photon-photon annihilation, particularly #gamma##gamma##->#W"+W"-, #gamma##gamma##->#Higgs bosons, and higher-order loop processes, such as #gamma##gamma##->##gamma##gamma#, Z#gamma# and ZZ. Since each photon can be resolved into a W"+W"- pair, high energy photon-photon collisions can also provide a remarkably background-free laboratory for studying WW collisions and annihilation. We also review high energy #gamma##gamma# tests of quantum chromodynamics, ...

318

Triple-vector-boson processes in [gamma][gamma] colliders  

Energy Technology Data Exchange (ETDEWEB)

We study the production of three gauge bosons ([ital W][sup +][ital W][sup [minus

1994-11-01

319

The interaction zone of a #gamma##gamma# collider at TESLA  

International Nuclear Information System (INIS)

German 2003 p. 24 Germany Klemz, G. Moenig, K. Sekaric, J. Stahl,

321

Semihard production of tensor mesons in. gamma. gamma. -collisions and the perturbative Odderon  

Energy Technology Data Exchange (ETDEWEB)

The cross sections of neutral tensor mesons T=a{sub 2}, f, f', ... production in the exclusive {gamma}{gamma}{yields}TT' or semiexclusive {gamma}{gamma}{yields}TX processes (three gluon exchange) in the semihard region s>>vertical stroketvertical stroke>1 GeV{sup 2} are calculated. The relation of investigated processes to the problem of perturbative Odderon is discussed. The possibility of measurements at LEP and at a future {gamma}{gamma}-colliders is discussed too. (orig.).

1992-03-01

322

Detection of the heavy Higgs boson at [gamma][gamma] colliders  

Energy Technology Data Exchange (ETDEWEB)

We consider the possibility of detecting a heavy Higgs boson ([ital m][sub [ital H

1993-07-01

323

#gamma#-#gamma# angular correlation for "1"0"1Tc transitions  

International Nuclear Information System (INIS)

... correlation beta-minus decay coincidence spectrometry experimental data

324

Laser: a Tool for Optimization and Enhancement of Analytical Methods  

Energy Technology Data Exchange (ETDEWEB)

In this work, we use lasers to enhance possibilities of laser desorption methods and to optimize coating procedure for capillary electrophoresis (CE). We use several different instrumental arrangements to characterize matrix-assisted laser desorption (MALD) at atmospheric pressure and in vacuum. In imaging mode, 488-nm argon-ion laser beam is deflected by two acousto-optic deflectors to scan plumes desorbed at atmospheric pressure via absorption. All absorbing species, including neutral molecules, are monitored. Interesting features, e.g. differences between the initial plume and subsequent plumes desorbed from the same spot, or the formation of two plumes from one laser shot are observed. Total plume absorbance can be correlated with the acoustic signal generated by the desorption event. A model equation for the plume velocity as a function of time is proposed. Alternatively, the use of a static laser beam for observation enables reliable determination of plume ...

1997-01-01

325

Monte Carlo methods, models, and applications for the Advanced Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

A three-dimensional, continuous-energy, coupled neutron-gamma Monte Carlo model of the advanced neutron source (ANS) final preconceptual reference core design has been developed using MCNP Version 3b. This model contains the reactor core with control rods, the heavy-water reflector tank with shutdown rods and representative beam tubes, and the outer light-water poor. Eighty homogenized fuel zones per fuel element are used to represent the radical and axial {sup 235}U fuel grading. This model is the most sophisticated, physically accurate reactor physics model of the ANS currently available. The purpose of this summary is to demonstrate the MCNP methods and applications for the ANS.

1990-06-01

326

Magnetic properties of B and AB-spinels Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Ni, Mg) materials  

Energy Technology Data Exchange (ETDEWEB)

The magnetic properties of diluted spinels Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) systems have been studied by mean field theory, probability law and high-temperature series expansions method in the range 0 {<=} x {<=} 1. The exchange interactions are calculated by the first and second theory, respectively. The magnetic phase diagrams of Zn{sub 1-x}M{sub x}Fe{sub 2}O{sub 4} (M = Mg, Ni) are calculated by the high-temperature series expansions, combined with the Pade approximants method. The critical exponent associated with the magnetic susceptibility ({gamma}) is deduced.

2010-08-06

327

Electronic structure, Compton profiles and optical properties of TaC and TaN  

International Nuclear Information System (INIS)

Isotropic Compton profiles of TaC and TaN have been measured for the first time, at an intermediate resolution, using 662 keV #gamma#-radiation. Energy bands, density of states and Fermi surface topology of TaC and TaN have been computed using linear combination of atomic orbitals with density functional theory and full potential linearised augmented plane wave method. Both band structure calculations predict the metallic character of TaC and TaN. The electron momentum densities calculated using various approaches of density functional theory are compared with the present measurements. On the basis of Mulliken's population, it is also seen that TaC has more covalent bonding than TaN. The optical properties computed using full potential linearised augmented plane wave method are explained in terms of intraband transitions.

2010-11-01

328

Chemical Analysis of Solid-State Irradiated Human Insulin  

British Library Electronic Table of Contents (United Kingdom)

Purpose To study the chemical modifications induced upon irradiation of solid human insulin at radiosterilization doses and investigate the influence of the absorbed dose on radiolysis. Materials and Methods Volatile radiolytic products were monitored by gas chromatography coupled with mass spectrometry (GC-MS) and non-volatile products by two different high performance liquid chromatography (HPLC) methods: the formation of higher molecular weight proteins was assessed by size exclusion liquid chromatography whereas assays for related compounds and chemical potency tests were carried out using reverse-phase HPLC-UV. Conformational changes were investigated by measurements of circular dichroism. Results After gamma irradiation at 10?kGy, the recovery of insulin was 96.8%; higher molecular w...

2006-01-01

329

{gamma}{gamma} Cross-sections and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We summarize the predictions of different models for total {gamma}{gamma} cross-sections. The experimentally observed rise of {sigma}{sub {gamma}}{sub {gamma}} with s radical {sub {gamma}}{sub {gamma}}, faster than that for {sigma}{sub p-barp}, {sigma}{sub {gamma}}{sub p} is in agreement with the predictions of the Eikonalized Minijet Models as opposed to those of the Regge-Pomeron models. We then show that a measurement of {sigma}{sub {gamma}}{sub {gamma}} with an accuracy of < or approx. 8-9% (6-7%) is necessary to distinguish among different Regge-Pomeron type models (the different parameterisations of the EMM models) and a precision of < or approx. 20% is required to distinguish the predictions of the EMMs and of those models which treat 'photon like a proton', for the energy range ...

2001-10-11

330

e#gamma# and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The results that can be expected by e#gamma# and #gamma##gamma# colliders in future are summarized. e#gamma# and #gamma##gamma# colliders have many fine possibilities, and are the economical selection for utilizing future e"+e"- colliders more effectively. e#gamma# and #gamma##gamma# colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e"+e"- collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e#gamma# and #gamma##gamma# colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e"+e"- accelerators. The production of #gamma#-beam is explained. As for the physics ...

1994-02-01

331

Top pair production in e+e- and {gamma}{gamma} processes  

Energy Technology Data Exchange (ETDEWEB)

We analyze spin correlations between top quark and anti-top quark produced at polarized e{sup +} e{sup -} and {gamma}{gamma} colliders. We consider a generic spin basis to find a strong spin correlation. Optimal spin decompositions for top quark pair are presented for e{sup +}e{sup -} and {gamma}{gamma} colliders. We show the cross- section in these bases and discuss the characteristics of results.

1998-02-01

332

Studying the triple-Higgs vertex in the process. gamma. gamma. yields HH at TeV energies  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process {gamma}{gamma}{yields}HH are calculated. It is shown that the cross section is measurable at TeV {gamma}{gamma} colliders and is marginally sensitive to the triple-Higgs variation. (orig.).

1992-06-04

333

Studying the triple-Higgs vertex in the process #gamma##gamma##->#HH at TeV energies  

International Nuclear Information System (INIS)

In the framework of the equivalence theorem the one-loop helicity amplitudes and cross section for the double Higgs production process #gamma##gamma##->#HH are calculated. It is shown that the cross section is measurable at TeV #gamma##gamma# colliders and is marginally sensitive to the triple-Higgs variation. (orig.).

334

New physics beyond the standard model at {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The complementarity of e{sup +}e{sup -} and {gamma}{gamma} colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios, we concentrate in detail on signatures for Large Extra Dimensions via the process {gamma}{gamma}{yields}WW.

2001-10-11

335

New physics beyond the standard model at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The complementarity of e"+e"- and #gamma##gamma# colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios, we concentrate in detail on signatures for Large Extra Dimensions via the process #gamma##gamma##->#WW.

2001-10-11

336

New Physics Beyond the Standard Model at Gamma-Gamma Colliders  

Energy Technology Data Exchange (ETDEWEB)

The complementarity of e{sup +}e{sub {minus}} and gamma-gamma colliders to discover and explore new physics beyond the Standard Model (SM) is discussed. After briefly surveying a number of various new physics scenarios the authors concentrate in detail on signatures for Large Extra Dimensions via the process gamma-gamma --> WW.

2000-08-07

337

Molecular recognition of nitrated fatty acids by PPAR[gamma  

Energy Technology Data Exchange (ETDEWEB)

Peroxisome proliferator activated receptor-{gamma} (PPAR{gamma}) regulates metabolic homeostasis and adipocyte differentiation, and it is activated by oxidized and nitrated fatty acids. Here we report the crystal structure of the PPAR{gamma} ligand binding domain bound to nitrated linoleic acid, a potent endogenous ligand of PPAR{gamma}. Structural and functional studies of receptor-ligand interactions reveal the molecular basis of PPAR{gamma} discrimination of various naturally occurring fatty acid derivatives.

2010-03-08

338

E{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

The results that can be expected by e{gamma} and {gamma}{gamma} colliders in future are summarized. e{gamma} and {gamma}{gamma} colliders have many fine possibilities, and are the economical selection for utilizing future e{sup +}e{sup -} colliders more effectively. e{gamma} and {gamma}{gamma} colliders were proposed by former USSR researchers at the beginning of 1980s, but recently, the prospect of realizing future e{sup +}e{sup -} collision type linear accelerator projects has become high, they have become to be considered seriously as the option of remodeling them. The high energy photon beam of e{gamma} and {gamma}{gamma} colliders is obtained by causing Compton reverse scattering, irradiating laser beam to the electron beam of e{sup +}e{sup -} accelerators. The production of {gamma}-beam is ...

1994-02-01

339

States with several particles in e{sup +}e{sup -} and {gamma}{gamma} colliders: technique of calculation and launch of a new physics; Etats a plusieurs particules dans les collisionneurs e{sup +}e{sup -} et {gamma}{gamma}: techniques de calcul et effets d'une nouvelle physique  

Energy Technology Data Exchange (ETDEWEB)

The mass generation in the Standard Model of Particles Physics relies on a spontaneous symmetry breaking mechanism. Its implementation is recalled, along with its constraints, both theoretical (Naturalness, Stability, Triviality, Unitarity) and experimental (limits of direct and indirect searches, prospects). Calculation techniques for observables evaluation in Perturbative Field Theory are described, particularly Helicity Amplitude method, which is given in details: fermions and vector bosons, massless and massive. Monte-Carlo integration, and structure functions approximations (which allows non-perturbative calculations) are also detailed. With these tools, a process giving to Physics beyond the Standard Model is studied: it leads to an experimental prediction for the LEP collision ring, taking the classical background into account. Technical aspects of a future photon linear collider are reviewed. The production of heavy vector bosons, either the classical Z for ...

1996-10-22

340

Quantitative descriptions of nonlinear gravitational galaxy clustering  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate nonlinear gravitational galaxy clustering, three different quantitative analyses were carried out: two-point correlation functions, {xi}(r); fractal dimensions, D{sub q}; and f(N) statistics. The relation between the exponent {gamma} of the correlation function ({xi}(r) {proportional to} r{sup -{gamma}}) and the fractal dimensions, D{sub q}, was derived with the help of the probability distribution function, f(N), for finding N galaxies within a volume V. The methods were applied to analyze the results of N-body simulations with power law initial density fluctuations ( {delta}{sub k} {sup 2} {proportional to} k{sup n}, n = 1, 0, -1 and -2). These analyses show that the exponent, {gamma}, of the power law {xi}(r) is approximately 2 in the nonlinear regime for models with n = 1 and 0. For models with n = -1 and -2, the correlation functions comprise two parts of the intermediate ...

1990-01-01

341

Effect of Collimation Slit and Shield Thickness in a Prompt Gamma-based Proton Beam Range Measurement System  

Energy Technology Data Exchange (ETDEWEB)

The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot ...

2007-07-01

342

Developments based on stochastic and determinist methods for studying complex nuclear systems; Developpements utilisant des methodes stochastiques et deterministes pour l'analyse de systemes nucleaires complexes  

Energy Technology Data Exchange (ETDEWEB)

In the field of reactor and fuel cycle physics, particle transport plays and important role. Neutronic design, operation and evaluation calculations of nuclear system make use of large and powerful computer codes. However, current limitations in terms of computer resources make it necessary to introduce simplifications and approximations in order to keep calculation time and cost within reasonable limits. Two different types of methods are available in these codes. The first one is the deterministic method, which is applicable in most practical cases but requires approximations. The other method is the Monte Carlo method, which does not make these approximations but which generally requires exceedingly long running times. The main motivation of this work is to investigate the possibility of a combined use of the two methods in such a way as to retain their advantages while avoiding ...

2000-05-19

343

SUSY at e{gamma}/{gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the sparticle production processes e{gamma} {yields} e tilde(Z tilde){sub 1} and {gamma}{gamma} {yields} (f tilde)(f tilde and bar) at high energy e{gamma} and {gamma}{gamma} colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e{gamma} colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e{gamma} {yields} (e tilde)(Z tilde){sub 1}. We show that the standard background processes e{gamma} {yields} {nu}W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e{gamma} {yields} (e ...

1994-04-01

344

SUSY at e#gamma#/#gamma##gamma# colliders  

International Nuclear Information System (INIS)

We investigate the sparticle production processes e#gamma# #-># e tilde(Z tilde)_1 and #gamma##gamma# #-># (f tilde)(f tilde and bar) at high energy e#gamma# and #gamma##gamma# colliders in the framework of the minimal supersymmetric standard model (MSSM). It will be shown that the e#gamma# colliders would be more suitable in searching for the heavy selectrons than ee colliders because of the low mass threshold of the process e#gamma# #-># (e tilde)(Z tilde)_1. We show that the standard background processes e#gamma# #-># #nu#W and eZ can be suppressed in terms of initial beam polarization as well as the kinematical cuts on the energy and angle of the final electron. Moreover, it will be argued that the experimental measurements of the cross sections for the processes e#gamma# #-># (e tilde)(Z tilde)_1 and ...

1994-04-01

345

Improvement of top shield analysis technology for CANDU 6 reactor  

Energy Technology Data Exchange (ETDEWEB)

As for Wolsung NPP unit 1, radiation shielding analysis was performed by using neutron diffusion codes, one-dimensional discrete ordinates code ANISN, and analytical methods. But for Wolsung NPP unit 2, 3, and 4, two-dimensional discrete ordinates code DOT substituted for neutron diffusion codes. In other words, the method of analysis and computer codes used for radiation shielding of CANDU 6 type reactor have been improved. Recently Monte Carlo MCNP code has been widely utilized in the field of radiation physics and other radiation related areas because it can describe an object sophisticately by use of three-dimensional modelling and can adopt continuous energy cross-section library. Nowadays Monte Carlo method has been reported to be competitive to discrete ordinate method in the field of radiation shielding and the former has been known to be superior to the latter for complex geometry problem. ...

1996-07-01

346

Development of a computerized portal verification scheme for pelvic treatment fields  

International Nuclear Information System (INIS)

Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing simulation films using a TV camera into images with 256 x 256 matrix and 8 bit gray levels. Initially a Canny edge detector is applied ...

1996-09-01

347

Radiotherapy for ocular lesions by electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV electron twice a week method. 2) For ...

1981-11-01

348

Radioanalytical methods of rare earth element determination  

International Nuclear Information System (INIS)

Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was ...

1989-06-01

349

Monte Carlo methods, models, and applications to the advanced neutron source  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on three-dimensional continuous-energy coupled neutron-gamma Monte Carlo models of the Advanced Neutron Source (ANS) final preconceptual and conceptual reference core designs developed using the Monte Carlo Neutron and Photon transport code (MCNP) Version 3b. These models contain the reactor core with control rods, the heavy water reflector tank with shutdown rods and some beam tubes, and the outer light water pool. Eighty homogenized fuel zones per fuel element are used to represent the radial and axial {sup 235}U fuel distribution. These models are the most sophisticated, physically accurate reactor physics models of the ANS currently available. The use of MCNP methods and applications to the ANS are demonstrated. Beam tube studies, coolant voiding studies, and many criticality studies have already been performed, as have studies with variance reduction techniques. In comparison with deterministic ...

1991-09-01

350

Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a {sup 60}Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of the two counts gradually increased with ...

2009-07-15

351

Probing anomalous quartic couplings in e{gamma} and {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We analyze the potential of the e{sup +}e{sup -} linear colliders, operating in the e{gamma} and {gamma}{gamma} modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2){sub L}(circle times)U(1){sub Y} chiral operators of order p{sup 4} that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e{gamma} and {gamma}{gamma} modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10{sup -2} at 90% C.L. Moreover, the information gathered in the e{gamma} mode can be used to reduce the ambiguities of the e{sup +}e{sup -} mode.

2001-10-01

352

Probing anomalous quartic couplings in e#gamma# and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We analyze the potential of the e"+e"- linear colliders, operating in the e#gamma# and #gamma##gamma# modes, to probe anomalous quartic vector-boson interactions through the multiple production of W's and Z's. We examine all SU(2)_L(circle times)U(1)_Y chiral operators of order p"4 that lead to new four-gauge-boson interactions but do not alter trilinear vertices. We show that the e#gamma# and #gamma##gamma# modes are able not only to establish the existence of a strongly interacting symmetry breaking sector but also to probe for anomalous quartic couplings of the order of 10"-"2 at 90% C.L. Moreover, the information gathered in the e#gamma# mode can be used to reduce the ambiguities of the e"+e"- mode.

2001-10-01

353

Development of radiological emergency preparedness technology  

Energy Technology Data Exchange (ETDEWEB)

Large-scale field tracer experiments have been conducted on Ulchin, Wolsung and Daeduk sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear sites. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. both processes, of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of Biological research for the radiation protection had contained the search of biological microanalytic methods for assessing the health effect by ...

2000-04-01

354

The NIR Upgrade to the SALT Robert Stobie Spectrograph  

CERN Document Server

The near infrared (NIR) upgrade to the Robert Stobie Spectrograph (RSS) on the Southern African Large Telescope (SALT), RSS/NIR, extends the spectral coverage of all modes of the visible arm. The RSS/NIR is a low to medium resolution spectrograph with broadband imaging, spectropolarimetric, and Fabry-Perot imaging capabilities. The visible and NIR arms can be used simultaneously to extend spectral coverage from approximately 3200 A to 1.6 um. Both arms utilize high efficiency volume phase holographic gratings via articulating gratings and cameras. The NIR camera is designed around a 2048x2048 HAWAII-2RG detector housed in a cryogenic dewar. The Epps optical design of the camera consists of 6 spherical elements, providing sub-pixel rms image sizes of 7.5 +/- 1.0 um over all wavelengths and field angles. The exact long wavelength cutoff is yet to be determined in a detailed thermal analysis and will depend on the semi-warm ...

2006-01-01

355

Technique of moving picture overlapping for view simulation by means of the moving picture processing; Dogazo kaiseki ni motozuku keikan simulation no tame no dogazo goseiho  

Energy Technology Data Exchange (ETDEWEB)

This paper proposes a technique of moving picture overlapping for view simulation by means of the moving picture processing. The continuous pictures of actual natural view gotten from video and the pictures of building structure made by computer graphics (CG) were overlapped. The CG pictures of building structure model were made considering the camera parameters, such as position and direction of camera. In order to analyze the continuously changing camera parameters, optical flows were determined from the view video. Based on these results, the overlapping video was made, in which the building structure was incorporated into the actual view. Furthermore, the proposed technique of moving picture overlapping was applied to the view simulation of transmission line tower. Consequently, it was demonstrated that the overlapped moving pictures can provide information which can not be obtained from the still pictures. It was ...

1994-11-01

356

Validation of the 3D finite element transport theory code EVENT for shielding applications  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with the validation of the 3D deterministic neutral-particle transport theory code EVENT for shielding applications. The code is based on the finite element-spherical harmonics (FE-P{sub N}) method which has been extensively developed over the last decade. A general multi-group, anisotropic scattering formalism enables the code to address realistic steady state and time dependent, multi-dimensional coupled neutron/gamma radiation transport problems involving high scattering and deep penetration alike. The powerful geometrical flexibility and competitive computational effort makes the code an attractive tool for shielding applications. In recognition of this, EVENT is currently in the process of being adopted by the UK nuclear industry. The theory behind EVENT is described and its numerical implementation is outlined. Numerical results obtained by the code are compared with predictions of the Monte Carlo code MCBEND and ...

2000-03-01

357

Using the alkoxomethod to obtain the oxide phases of Fe_2O_3-Y_2O_3 system  

International Nuclear Information System (INIS)

Production of Fe_2O_3, Y_2O_3, YFeO_3, Y_3Fe_5O_1_2 powders using the alkoxomethod - during hydrolysis by yttrium and iron alcohol solutions, is studied. It is stated that production of the powders of Y_2O_3-Fe_2O_3 system oxides using alkoxomethod permits to decrease essentially the reaction volumes, number of operations, their duration as compared to the cooxidation of oxide hydrates from inorganic salt aqueous solutions. During heat treatment of iron (3) alcohol hydrolysis products #gamma#-Fe_2O_3 is first crystallized by contrast to #alpha#-FeOOH, usually produced by deposition from solutions. Further heat treatment of #gamma#-Fe_2O_3 results in production of #alpha#-Fe_2O_3. Conditions for crystallization of Y_3Fe_5O_1_2 and YFeO_3 phases, prepared by both methods, and their crystallite mean sizes are close, but the powders obtained from alcohols are more homogeneous.

358

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

Energy Technology Data Exchange (ETDEWEB)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino mass by nuclear ...

1993-12-31

359

Topics in axion and neutrino physics, time reversal violation, and Higgs detection  

International Nuclear Information System (INIS)

A number of systems which can elucidate physics beyond the standard model are investigated. The production of axions by a network of cosmic strings in the early universe is calculated. This allows an upper bound to be placed on the axion decay constant, and provides the preferred Peccei-Quinn symmetry breaking scale for axions to make up the dark matter of the universe. Models of neutrino mass arising from strong interactions are investigated. These models possess a massless up quark, thereby solving the strong CP problem. A systematic analysis of the contributions to time reversal violating atomic and molecular electric dipole moments is presented. Specific contributions from the supersymmetric standard model are calculated. The contributions arising from the QCD vacuum angle are also discussed. Prospects for detecting the axion by its long range coherent force are related to measurable electron dipole moments. A method for measuring neutrino mass by nuclear ...

360

Thermal-resistant radiation sensing system using optical fiber for monitoring progress of chemical decontamination  

Energy Technology Data Exchange (ETDEWEB)

A thermal-resistant radiation sensing system using optical fiber has been developed. The system is for monitoring progress of chemical decontamination and able to measure the gamma-ray level in a hot solution of decontamination chemicals in situ. Our sensor head makes use of thermal-resistant NaI (T1) and it is connected to an optical fiber bundle. Scintillation photons pass from the NaI (T1) into the end of the bundle. This part of the system can withstand temperatures of over 100degC. At the far end of the optical fiber bundle, the scintillation photons are converted into fluorescent photons using a wavelength-shifting fiber. These photons are transferred to a distant photomultiplier tube through two thin transparent optical fibers. Furthermore, we propose a self-compensation technique for the dependence of scintillator sensitivity on. This compensation method is based on the correlation between temperature, sensitivity, and scintillation ...

1999-07-01

361

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis; Determination of optimum conditions of image processing  

Energy Technology Data Exchange (ETDEWEB)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...

1993-06-01

362

The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis  

International Nuclear Information System (INIS)

A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same ...

1993-01-01

363

Study on the stability of the Maytenus aquifolium Martius chemical components submitted to ionizing radiation (X-ray and #gamma#)  

International Nuclear Information System (INIS)

The interest for medicinal plants has raised again in the last decades, after overcoming a declination period caused by the advances in the researches and development of the synthetic drugs industries. This growing interest has been stimulated mainly by searching cheap and accessible alternative therapies. However, in order to have natural products based treatment in an efficient and safety way, it is necessary to guarantee the plant authenticity, finding adulterations and to assure a low level of microbiological contaminations to avoid damages to consumer's health. The decontamination method should be chosen for eliminating or reduce the microorganisms level without loss of the plant active constituents that would destroy its therapeutic action. At the present work, the possibility of using #gamma# and X electromagnetic radiations to sterilize a Brazilian medicinal plant (Maytenus aquifolium Martius, Celastraceae), which shows anti-ulcer ...

364

Slide Rule for Rapid Response Estimation of Radiological Dose from Criticality Accidents  

Energy Technology Data Exchange (ETDEWEB)

This paper describes a functional slide rule that provides a readily usable ?in-hand? method for estimating nuclear criticality accident information from sliding graphs, thereby permitting (1) the rapid estimation of pertinent criticality accident information without laborious or sophisticated calculations in a nuclear criticality emergency situation, (2) the appraisal of potential fission yields and external personnel radiation exposures for facility safety analyses, and (3) a technical basis for emergency preparedness and training programs at nonreactor nuclear facilities. The slide rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, distance from the fission source, and time-after criticality accidents for five different critical systems. Another sliding graph permits the estimation of critical solution fission yields based upon fissile material concentration, critical vessel ...

1999-09-20

365

Selective dissolution and surface enrichment of alloy components of passivated Fe 18Cr and Fe 18Cr3Mo single crystals  

International Nuclear Information System (INIS)

The possible surface enrichment of chromium and molybdenum during dissolution of Fe18Cr (110) and Fe18Cr3Mo (110) alloys at constant potentials in the passive region is elucidated by taking into account quantitative information on partial dissolution rates of alloy components as measured by #gamma#-spectrometry and on chemical composition of passivating films as measured by ESCA and AES. When combining results from all methods it is found that chromium under all conditions is enriched in the passivating films. An accumulation of chromium in the alloy is also indicated. For molybdenum, an enrichment in the passive film is observed at -0.2 V (SCE), whereas in the potential interval 0.1 - 0.9 V, the molybdenum enrichment as determined by ESCA and AES is hardly significant. On the other hand, #gamma#-spectrometry gives a clear indication of molybdenum enrichment in both potential. (author).

2008-12-30

366

Performance of ZnMoO4 crystal as cryogenic scintillating bolometer to search for double beta decay of molybdenum  

CERN Document Server

Zinc molybdate (ZnMoO4) single crystals were grown for the first time by the Czochralski method and their luminescence was measured under X ray excitation in the temperature range 85-400 K. Properties of ZnMoO4 crystal as cryogenic low temperature scintillator were checked for the first time. Radioactive contamination of the ZnMoO4 crystal was estimated as <0.3 mBq/kg (228-Th) and 8 mBq/kg (226-Ra). Thanks to the simultaneous measurement of the scintillation light and the phonon signal, the alpha particles can be discriminated from the gamma/beta interactions, making this compound extremely promising for the search of neutrinoless Double Beta Decay of 100-Mo. We also report on the ability to discriminate the alpha-induced background without the light measurement, thanks to a different shape of the thermal signal that characterizes gamma/beta and alpha particle interactions.

2010-01-01

367

Numerical solutions of high-frequency perturbations in Bianchi type IX models  

Energy Technology Data Exchange (ETDEWEB)

The problem in perturbation theory in general relativity is finding a natural gauge which simplifies the equations considerably. We solved the first and second order perturbation equations in the ''Lorentz gauge'' using the two-timing method. The equations were deduced from the equations of Einstein in the presence of a matter energy-momentum tensor of a perfect fluid with equation of state p = (..gamma..-1) rho. It is found that the 0--0 component of the first order equations together with the gauge conditions are consistent with the Bianchi type V model, without axial symmetry. It represents a ''ground state'' situation of the Bianchi type IX model (Mixmaster model.) The second order equations, describing the reaction back of the gravitational waves on the slowly varying background, give rise to rotation and will disturb the isotropization mechanism. The numerical ...

1983-05-15

368

Lifetimes of superdeformed nuclei in the mass region A {approx}150 with the Eurogam multidetector array; Durees de vie de noyaux superdeformes de la region de masse A {approx}150 mesurees avec le multicompteur Eurogam  

Energy Technology Data Exchange (ETDEWEB)

This work concerns the study of the nuclear superdeformation phenomenon in the rare earth region (A {approx} 150). The superdeformed (SD) states in Gadolinium and Dysprosium isotopes were produced via heavy-ion induced reactions and studied with the (EUROGAM EUROpean GAmma-ray Microscope) gamma multidetector array. Precise level attenuation method (DSAM). From the derived quadrupole moments, we find large differences in deformation between the yrast bands in neighbour nuclei explained in terms of the case of nuclei corresponding to an axis ratio of 2:1, the shell gaps are not fixed at a specific particle number and deformation. Furthermore the present results indicate that the deformations associated with identical bands are different supporting the picture that mass and deformation changes tend to compensate in SB bands with the same moments of inertia. (author). 114 refs.

1996-05-13

369

Incineration of {sup 241}Am induced by thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

An experimental study of the {sup 241}Am incineration in a high-intensity thermal neutron flux was carried out at the high-flux reactor of the Institut Laue-Langevin in Grenoble. The combination of nuclear {gamma}-ray spectroscopy and off-line mass spectrometry methods made possible the measurement of several parameters of the transmutation chain and the first experimental determination of the unknown {sup 242gs}Am thermal neutron capture cross section, which plays an essential role in the {sup 241}Am incineration process. During a 19 days irradiation in a thermal neutron flux of 5.6x10{sup 14} n/(s cm{sup 2}), (46{+-}5)% of the initial {sup 241}Am was transmuted by neutron capture of which (22{+-}8)% was incinerated by nuclear fission. A value of the thermal neutron cross section of {sup 242gs}Am(n,{gamma}) of (330{+-}50) barns was obtained. We show that this keeps the option open to incinerate {sup 241}Am by ...

2001-10-22

370

Improvement of banana through biotechnology and mutation breeding  

International Nuclear Information System (INIS)

Protocols were standardized for in vitro propagation of several elite and diverse banana accessions using shoot tip explants. Tissue culture raised plants were field planted at multiple locations. Studies were undertaken for the induction of mutations using multiple shoot cultures of six selected cultivars, Shreemanti (AAA), Basrai (AAA), Lal Kela (AAA), Rasthali (AAB), Karibale Monthan (ABB) and a wild diploid (BB). These shoot cultures were irradiated at different doses of gamma rays (0-100 Gy) and subcultured thrice (up to M_1V_3) to separate shimeras, followed by induction of rooting (M_1V_4). In general, the rate of multiplication had a negative association with the dose of gamma rays. Enhanced multiplication of shoots was noticed at lower doses. The proliferation of shoots was arrested beyond 50 Gy and a dose of 70 Gy was completely lethal for all the genotypes studied. The rooted plantlets were hardened in the green house and in the ...

1998-10-01

371

Experience with abdominal gamma imaging in patients with bleeding of the lower digestive tube  

International Nuclear Information System (INIS)

This study concerns our experiences with abdominal gamma imaging using Tc-99m colloid and with abdominal angiography using Tc-99m-pyrophosphate labelled erythrocytes ''in vivo'' based on the modified technique described by Callahan. The dynamic or perfusion phase was first performed, then the static phase during which for the first two hours scans were taken every 15 minutes and thereafter every 4-6 hours. The routine image corresponds to the first, although it was necessary at times to take oblique projections. The study was felt to be accomplished after 48 hours upon observing no extravasation of radioactive material in the abdominal region, or upon detecting a bleeding site. The investigation was performed on 11 patients, 8 having positive scans of abdominal extravasation, later confirmed in 6 by endoscopy and by surgery. In 2, the presence of salmonelosis was shown by laboratory analysis. Endoscopy and angiography XR are both invasor ...

1985-04-25

372

Effect of gamma irradiation on the antimicrobial and free radical scavenging activities of Glycyrrhiza glabra root  

International Nuclear Information System (INIS)

The efficacy of gamma irradiation as a method of decontamination for food and herbal materials is well established. In the present study, Glycyrrhiza glabra roots were irradiated at doses 5, 10, 15, 20 and 25 kGy in a cobalt-60 irradiator. The irradiated and un-irradiated control samples were evaluated for phenolic contents, antimicrobial activities and DPPH scavenging properties. The result of the present study showed that radiation treatment up to 20 kGy does not affect the antifungal and antibacterial activity of the plant. While sample irradiated at 25 kGy does showed changes in the antibacterial activity against some selected pathogens. No significant differences in the phenolic contents were observed for control and samples irradiated at 5, 10 and 15 kGy radiation doses. However, phenolic contents increased in samples treated with 20 and 25 kGy doses. The DPPH scavenging activity significantly (p<0.05) increased in all irradiated ...

2010-04-01

373

Dipole response of {sup 88}Sr up to the neutron-separation energy  

Energy Technology Data Exchange (ETDEWEB)

Dipole and quadrupole excitations in the semimagic N{sup .} = 50 nucleus {sup 88}Sr were investigated at the superconducting electron linear accelerator ELBE with bremsstrahlung produced at electron energies of 9.0, 13.2, and 16.0 MeV. About 160 {gamma} transitions were identified up to 12 MeV. By using polarized photons linear polarizations of about 50 {gamma} transitions were measured. In the energy range of 6 - 12 MeV there is only one M1 transition while all other transitions have E1 character. Statistical methods were applied in order to filter out inelastic transitions and to correct the intensities of the ground-state transitions for their branching ratios. The photoabsorption cross section obtained in this way provides information about the extension of the Giant Dipole Resonance towards energies below the neutron-separation energy. The experimental results are compared with existing data beyond the ...

2007-07-01

374

DOE personnel neutron dosimetry evaluation and upgrade program  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter is presently being developed for application to gamma, neutron, and beta radiation. An Effective Dose ...

1988-10-01

375

A study on the radiation and environmental safety -Development of a real-time radiological dose assessment system-  

Energy Technology Data Exchange (ETDEWEB)

The real-time dose assessment system under development has been updated and the technology for tracer experiment has been established. The calculation of external gamma dose is the most difficult and time-consuming part of the dose calculations. The characteristics of external gamma exposure have been investigated and the method for reducing the calculation time has been devised. The internal exposure via the ingestion of the contaminated foodstuffs is one of the important pathways to the total radiological exposure. In the emergency, it is necessary to take an action such like food ban to protect the internal exposure. An algorithm for the interface between the real-time system and the food chain model has been provided. The second field tracer experiment over flat terrain has been carried out on a plain in Iksan city in Junrabook-Do. Sequential tracer sampler which can be sampled the tracer gas over arbitrary 12 time ...

1995-07-01

376

A radionuclide analyzer of total sulfur in coal  

International Nuclear Information System (INIS)

The devised radionuclide analyzer for the determination of total sulfur in coal includes two radionuclide sources with different energies, which are accommodated in collimators fitted with adjustable diaphramgs. The sample compartment is located between the two sources. Moreover, an X-ray fluorescence standard can be slid into the sample compartment. A proportional detector for X-ray fluorescence and scattered gamma radiation is located off the sample compartment. The input of the proportional detector is interfaced to the output of a high-voltage supply, the output, to the information input of a control-and-evaluation unit. One of the control outputs of the control-and-evaluation unit is connected to the input of the sliding mechanism for the X-ray fluorescence standard. This arrangement enables automatic energy calibration of the analyzer. The analyzer can measure not only total sulfur in coal by radionuclide X-ray fluorescence analysis but also ash in coal by ...

1987-05-13

377

Triple-vector-boson processes in #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study the production of three gauge bosons (W"+W"-Z"0 and W"+W"-#gamma#) at the next generation of linear e"+e"- colliders operating in the #gamma##gamma# mode. We analyze the total cross sections as well as several kinematical distributions of the final state particles. We find out that a linear e"+e"- machine operating in the #gamma##gamma# mode will produce 5--10 times more three-gauge-boson states compared to the standard e"+e"- mode at high energies.

378

Singlet scalars as Higgs imposters at the Large Hadron Collider  

CERN Document Server

An electroweak singlet scalar can couple to pairs of vector bosons through loop-induced dimension five operators. Compared to a Standard Model Higgs boson, the singlet decay widths in the diphotons and Z gamma channels are generically enhanced, while decays into massive final states like WW and ZZ are kinematically disfavored. The overall event rates into gamma gamma and Z gamma can exceed the Standard Model expectations by orders of magnitude. Such a singlet may appear as a resonant signal in the gamma gamma and Z gamma channels, even with a mass above the WW kinematic threshold.

2011-01-01

379

Probing anomalous top-quark couplings induced by dim.6 operators at photon colliders  

International Nuclear Information System (INIS)

Possible anomalous top-quark couplings induced by SU(2)xU(1) gauge-invariant dimension-6 effective operators were studied in the process of ttbar productions and decays at polarized #gamma##gamma# colliders. Two CP-violating asymmetries, a linear-polarization asymmetry and a circular-polarization asymmetry, were computed including both non-standard ttbar#gamma# and #gamma##gamma#H couplings. An optimal-observable analysis for the process #gamma##gamma##->#ttbar#->#l"#+-# was performed in order to estimate the precision for determination of all relevant non-standard couplings, including the anomalous tbW coupling.

2004-06-21

380

Corrosion resistance of #gamma#-solid solution and hardening #gamma#'-phase of nickel alloys in sodium sulfate and chloride melts  

International Nuclear Information System (INIS)

Corrosion testings of model alloys, corresponding by chemical composition to simple and complex-alloyed #gamma#- and #gamma#'-phases of nickel heat-resistant alloys are conducted in sodium sulfate and chloride melts. It is ascertained that heat resistant nickel alloys containing over 50 % of hardening #gamma#'-phase, are subject to disastrous sulfide corrosion (SC). Resistance against SC alloys containing below 50 % of #gamma#'-phase is determined by the resistance of #gamma#-solid solution. 10 refs., 3 figs., 2 tabs.

381

Calibration of cylindrical detectors using a simplified theoretical approach  

Energy Technology Data Exchange (ETDEWEB)

The calibration of cylindrical detectors using different types of radioactive sources is a matter of routine. The most accurate method, that of experiment, is limited by several factors when the energy interval is broad, requiring a relatively large number of primary standards, implying considerable investment of money and time. Several other techniques can be used instead, including Monte Carlo simulations and semi-empirical methods. Calculations based on the first technique require good definition of the geometry and materials, including the dead layer and window thickness together with an accurate set of cross-sections. The second technique requires two different types of experimental input, the first being from use of sources emitting cascade {gamma} rays and the second from use of sources emitting isolated {gamma} rays in order to cover the wide energy range and provide coincidence-summing ...

2006-09-15

382

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

Energy Technology Data Exchange (ETDEWEB)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm{sup -3} or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear ...

2007-08-21

383

An integrated Tomographic Gamma Scanning system for non-destructive assay of radioactive waste  

International Nuclear Information System (INIS)

The Tomographic Gamma Scanning (TGS) technique is a relatively new method in the field of non-destructive assay (NDA) of radioactive waste. The TGS technique combines High Resolution Gamma Spectrometry (HRGS) with Three-Dimensional (3-D) low spatial resolution transmission and emission image reconstruction techniques to achieve assay goals. When compared to the traditional methods such as Segmented Gamma Scanning (SGS), the TGS technique can yield better accuracies for cases where the radionuclide is distributed non-uniformly in a heterogeneous matrix. The TGS technique is ideally suited for low-to-moderate density waste matrices, say 1.0 g cm"-"3 or below for 55 US gal. drums, although it can be extended to higher densities by using alternative approaches to the design or analyses. Recently Canberra Industries designed, built and characterized four such TGS systems for nuclear ...

2007-08-21

384

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

385

Time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

1992-01-01

386

Time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.

1992-09-01

387

Technique for compressing light intensity ranges utilizing a specifically designed liquid crystal notch filter  

Energy Technology Data Exchange (ETDEWEB)

A pin hole camera assembly for use in viewing an object having a relatively large light intensity range, for example a crucible containing molten metal in an atomic vapor laser isotope separation (AVLIS) system is disclosed herein. The assembly includes means for optically compressing the light intensity range appearing at its input sufficient to make it receivable and decipherable by a standard video camera. To accomplish this, the assembly utilizes the combination of interference filter and a liquid crystal notch filter. The latter which preferably includes a cholesteric liquid crystal arrangement is configured to pass light at all wavelengths, except a relatively narrow wavelength band which defines the filter's notch, and includes means for causing the notch to vary to at least a limited extent with the intensity of light at its light incidence surface.

1988-01-01

388

Study on the characterization of the neutron radiography facility in HANARO for two-phase flow research  

Energy Technology Data Exchange (ETDEWEB)

For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.

2001-01-01

389

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

390

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.

1986-01-15

391

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).

1986-01-01

392

Further time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 [mu]s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

1992-01-01

393

Further time-resolved electron-beam characterizations with optical transition radiation  

Energy Technology Data Exchange (ETDEWEB)

Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.

1992-12-31

394

Simulation for position determination of distal and proximal edges for SOBP irradiation in hadron therapy by using the maximum likelihood estimation method  

Energy Technology Data Exchange (ETDEWEB)

In radiation therapy with hadron beams, conformal irradiation to a tumour can be achieved by using the properties of incident ions such as the high dose concentration around the Bragg peak. For the effective utilization of such properties, it is necessary to evaluate the volume irradiated with hadron beams and the deposited dose distribution in a patient's body. Several methods have been proposed for this purpose, one of which uses the positron emitters generated through fragmentation reactions between incident ions and target nuclei. In the previous paper, we showed that the maximum likelihood estimation (MLE) method could be applicable to the estimation of beam end-point from the measured positron emitting activity distribution for mono-energetic beam irradiations. In a practical treatment, a spread-out Bragg peak (SOBP) beam is used to achieve a uniform biological dose distribution in the whole target volume. Therefore, in the ...

2005-12-21

395

DOE assay methods used for characterization of contact-handled transuranic waste  

International Nuclear Information System (INIS)

US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not ...

396

DOE assay methods used for characterization of contact-handled transuranic waste  

Energy Technology Data Exchange (ETDEWEB)

US Department of Energy methods used for characterization of contact-handled transuranic (CH-TRU) waste prior to shipment to the Waste Isolation Pilot Plant (WIPP) are described and listed by contractor site. The methods described are part of the certification process. All CH-TRU waste must be assayed for determination of fissile material content and decay heat values prior to shipment and prior to storage on-site. Both nondestructive assay (NDA) and destructive assay methods are discussed, and new NDA developments such as passive-action neutron (PAN) crate counter improvements and neutron imaging are detailed. Specifically addressed are assay method physics; applicability to CH-TRU wastes; calibration standards and implementation; operator training requirements and practices; assay procedures; assay precision, bias, and limit of detection; and assay limitation. While PAN is a new technique and does not ...

1991-08-01

397

Measurement of the branching fractions for $J/\\psi\\to\\gamma\\pi^0$, $\\gamma\\eta$ and $\\gamma\\eta^{\\prime}$  

CERN Document Server

The decay modes $\\jpsi\\ar\\gamma\\pi^0, \\gamma\\eta$ and $\\gamma\\etap$ are analyzed using a data sample of 58 million $\\jpsi$ decays collected with the BESII detector at BEPC. The branching fractions are determined to be: $Br(\\jpsi\\ar\\gamma\\pi^0)=(3.13^{+0.65}_{-0.44})\\times10^{-5}$, $Br(\\jpsi\\ar\\gamma\\eta)=(11.23\\pm0.89)\\times10^{-4}$, and $Br(\\jpsi\\ar\\gamma\\etap)=(5.55\\pm0.44)\\times10^{-3}$, where the errors are combined statistical and systematic errors. The ratio of partial widths $\\Gamma(\\jpsi\\ar\\gamma\\etap)/\\Gamma(\\jpsi\\ar\\gamma\\eta)$ is measured to be $4.94\\pm0.40$, and the singlet-octet pseudoscalar mixing angle of $\\eta-\\etap$ system is determined to be $\\theta_{P}=(-22.08\\pm0.81)^{\\circ}$.

2006-01-01

398

Single dilepton production at e"+e"-, e#gamma#, and #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We calculate the cross sections for the single production of doubly charged dileptons, both scalar and vector, at e"+e"-, e#gamma#, and #gamma##gamma# colliders at #sq root#s =500 GeV and 1 TeV. The e#gamma# mode is by far the most promising---dileptons whose coupling is as weak as #approx#10"-"4#alpha#_e_m can be observed, for masses virtually up to the kinematic limit. Dileptons of mass up to #sq root#s can also be seen in e"+e"- and #gamma##gamma# colliders, for couplings of order #alpha#_e_m. In all three colliders, most of the cross section comes from events in which the only particles detected are e"-e"- (or #mu#"-#mu#"- or #tau#"-#tau#"-), the decay products of the dilepton, yielding an unmistakable experimental signature.

399

Single charged top-pion production at next generation #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The future e"+e"- linear colliders can also operate in the e#gamma# or #gamma##gamma# modes. In the context of the top-color assisted technicolor (TC2) model, we study the single charged top-pion production process #gamma##gamma# #-># tb-bar#PI#_t"-. The results show that the production rates can reach the level of tens fb with reasonable parameter values. So one can expect that enough signals could be produced in future high-energy linear collider experiments. Furthermore, the flavor-changing (FC) decay mode #PI#_t"- #-># bc-bar is the best channel to detect the charged top pion due to the clean standard model background. With a large number of events and the clean background, the charged top pion should be observable at future linear colliders operating in #gamma##gamma# mode at the TeV energy scale

2008-09-01

400

Optimal beam polarizations for new-physics search through {gamma}{gamma}{yields}t t-bar {yields}lX/bX  

Energy Technology Data Exchange (ETDEWEB)

We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in {gamma}{gamma}{yields}t t-bar {yields}lX/bX for various beam polarizations in order to study possible anomalous t t-bar {gamma}, tbW and {gamma}{gamma}H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and {gamma}{gamma} colliders from the viewpoint of the anomalous-top-quark-coupling determination.

2005-11-15

401

Optimal beam polarizations for new-physics search through #gamma##gamma##->#t t-bar #->#lX/bX  

International Nuclear Information System (INIS)

We perform an optimal-observable analysis of the final charged-lepton/b-quark momentum distributions in #gamma##gamma##->#t t-bar #->#lX/bX for various beam polarizations in order to study possible anomalous t t-bar #gamma#, tbW and #gamma##gamma#H couplings, which could be generated by SU(2) x U(1) gauge-invariant dimension-6 effective operators. We find optimal beam polarizations that will minimize the uncertainty in determination of those non-standard couplings. We also compare e e-bar and #gamma##gamma# colliders from the viewpoint of the anomalous-top-quark-coupling determination.

2005-11-01

402

Atom-probe field-ion microscopy investigation of CMSX-4 Ni-base superalloy laser beam welds  

Energy Technology Data Exchange (ETDEWEB)

CMSX-4 superalloy laser beam welds were investigated by transmission electron microscopy and atom probe field-ion microscopy (APFIM). The weld microstructure consisted of fine (10- to 50-nm) irregularly shaped {gamma}` precipitates (0.65 to 0.75 volume fraction) within the {gamma} matrix. APFIM compositions of the {gamma} and {gamma}` phases were found to be different from those in the base metal. Concentration profiles across the {gamma} and {gamma}` phases showed extensive variations of Cr, Co and Al concentrations as a function of distance within the {gamma} phase. Calculated lattice misfits near the {gamma}/{gamma}` interface in the welds are positive values compared to the negative values for base metal. (orig.).

1996-09-01

403

Anomalous g_5"Z coupling at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study the constraints on the anomalous coupling g_5"Z that can be obtained from the analysis of the reaction #gamma##gamma##->#W"+W"-Z at future linear e"+e"- colliders. We find out that a 0.5 (1) TeV e"+e"- collider operating in the #gamma##gamma# mode can probe values of g_5"Z of the order of 0.15 (4.5x10"-"2) for an integrated luminosity of 10 fb"-"1. This shows that the ability to search for this anomalous interaction of the #gamma##gamma# mode is better than the one of the usual e"+e"- mode, and it is similar to the ability of the e#gamma# mode.

404

Accelerator aspects of {gamma}-{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

There are several on-going projects of e{sup +}e{sup -} colliders. If they are constructed, we can convert them into photon-photon ({gamma}-{gamma}) colliders by converting electron beams into {gamma} beams, irradiating laser beams just before the interaction point. In this report we discuss the technical issues on the accelerator.

2000-11-21

405

{sup 252}Cf-source-driven frequency analysis measurements with subcritical arrays of PWR fuel pins  

Energy Technology Data Exchange (ETDEWEB)

Experiments with fresh PWR fuel assemblies were performed to assess the {sup 252}Cf-source-driven frequency analysis method for measuring the subcriticality of spent fuel. The measurements at the Babcox and Wilcox Critical Experiments Facility mocked up between 17x17 fuel pins (single assembly) and a full array of 4961 fuel pins (about 17 fuel assemblies) in borated water with a fixed B concentration. For the full array, the B content of the water was varied from 1511 at delayed criticality to 4303 ppM. Measurements were done for various source-detector-fuel pin configurations; they showed high sensitivity of frequency analysis parameters to B content and fissile mass. Parameters such as auto and cross power spectral densities can be calculated directly by a more general model of the Monte Carlo code (MCNP-DSP). Calculation-measurement comparisons are presented. This model permits the validation of neutron and gamma ray transport calculational ...

1996-08-01

406

Unbiased cut selection for optimal upper limits in neutrino detectors the model rejection potential technique  

CERN Document Server

We present a method for optimising experimental cuts in order to place the strongest constraints (upper limits) on theoretical signal models. The method relies only on signal and background expectations derived from Monte-Carlo simulations, so no bias is introduced by looking at actual data, for instance by setting a limit based on expected signal above the ``last remaining data event.'' After discussing the concept of the ``average upper limit,'' based on the expectation from an ensemble of repeated experiments with no true signal, we show how the best model rejection potential is achieved by optimising the cuts to minimise the ratio of this ``average upper limit'' to the expected signal from the model. As an example, we use this technique to determine the limit sensitivity of kilometre scale neutrino detectors to extra-terrestrial neutrino fluxes from a variety of models, e.g. active galaxies and gamma-ray bursts. We ...

2003-01-01

407

Neutron shielding and constructional characteristics of a new type concrete and from borated clinker  

International Nuclear Information System (INIS)

A boron containing cement, which can be used as nuclear shielding material, is produced at pilot plant scale applying two different methods. In the first method, the raw mixture of a normal portland cement is mixed with pre-calcined colemanite, a calcium borate mineral, and clinkerized in a rotary kiln (borated-clinker). In the second method, the colemanite is mixed with an admixture, which contains mainly limestone and marl, and burnt in the rotary kiln to obtain a borated-lime composite. The borated-lime composite is then added to the normal portland cement clinker up to 2% B_2O_3 content for shielding purpose. The results have shown that the borated-clinker contained untolerable amount of free lime resulting in a decrease in compressive strength. The addition of the borated-lime composite to the normal portland cement clinker up to 1% B_2O_3 content did not alter the setting time and the volume expansion properties. The ...

1994-11-07

408

The two means method for the attenuation coefficient determination of archaeological ceramics from the North of Parana; Metodo dos dois meios para a determinacao do coeficiente de atenuacao de ceramicas arqueologicas do norte do Parana  

Energy Technology Data Exchange (ETDEWEB)

This work reports an alternative methodology for the linear attenuation coefficient determination ({mu} {rho}) of irregular form samples, in such a way that is not necessary to consider the sample thickness. With this methodology, indigenous archaeological ceramics fragments from the region of Londrina, north of Parana, were studied. These ceramics fragments belong to the Kaingaing and Tupiguarani traditions. The equation for the {mu} {rho} determination employing the two mean method was obtained and it was used for {mu} {rho} determination by the gamma ray beam attenuation if immersed ceramics, by turns, in two different means with known linear attenuation coefficient. By the other side, {mu} theoretical value was determined with the XCOM computer code. This code uses as input the ceramics chemistry composition and provides an energy versus mass attenuation coefficient table. In order to validate the two mean method ...

1997-12-31

409

Radwaste Drum Assay Technology by Segmented Gamma Scanning System  

Energy Technology Data Exchange (ETDEWEB)

Nuclear Act of Korea requires the manifest of low and intermediate level radioactive waste generated from nuclear power plants and other nuclear facilities prior to deliver to a disposal sites. Individual history records of the radioactive waste should be described the information about the activity of nuclides in the drum, total activity, weight, the type of waste. So a fully automated nuclide analysis assay system(non-destructive) of a radwaste drum was developed. For the nuclides that could not be analysed directly by MCA, the activities of the representative {gamma}-emitters(Cs-137, Co-60) contained in the drum were measured by using that system. Then the scaling factors were used to calculate the activities of {alpha} - and {beta}-emitters. This assay system divided a drum into 8 segments, a segment into 8 sectors to minimize analysis error, and used several methods(transmission ratio, differential peak absorption, mean density ...

2009-01-15

410

Radiation resistance of flexible graphites  

International Nuclear Information System (INIS)

Polymer sealing parts are widely used in various branches of engineering as detachable joints that operate at normal and cryogenic temperatures. They are also used in nuclear-power engineering to seal pumps, pipelines, etc., where they operate at 600-650 K under a neutron fluence of around 10"1"6 cm"-"2 (E #>=# 0.18 MeV) and concomitant #gamma#-irradiation of about 10"6 R. The fluoroplastic-based materials currently used degrade when irradiated in water at 320-360 K with a neutron fluence of 10"1"5 cm"-"2 (thermal neutrons) or 10"1"4 cm"-"2 (fast neutrons), and a concomitant #gamma#-irradiation dose of 2 x 10"6 R. The strength of these fluoroplastics decreases markedly after #gamma#-irradiation (from a cobalt source) at room temperature at doses above 10"6 R. For this reason, flexible and swelling graphites are finding ever increasing application. Graflex foils made of extra-pure natural graphite were found to be ...

411

Local-density-functional approach to the isostructural #gamma#-#alpha# transition in cerium using the self-consistent linearized-augmented-plane-wave method  

International Nuclear Information System (INIS)

The isostructural #gamma#-#alpha# phase transition of Ce which occurs at 8 kbar has been studied by means of fully self-consistent (non-muffin-tin potential) linearized-augmented-plane-wave energy band calculations carried out for five different values of the lattice constant. In contradiction to the 4f electron promotional model of the transition, the results yield essentially one 4f electron to be occupied in each phase but with the 4f wave function somewhat less localized, and therefore more bandlike, in the ''collapsed'' #alpha# phase. A singly occupied 4f state is shown to be consistent with the available experimental data. These results strongly support the picture of a 4f localized bold-arrow-left-right itinerant transition at the #gamma#-#alpha# transition and conflict with the promotional model in which some fraction of 4f electrons are transferred to the sd conduction bands. The weaker bonding of the 4f electrons, compared to that of ...

412

Failed nuclear fuel rod analysis by gamma computed tomography  

International Nuclear Information System (INIS)

Fuel rod failures produce a release of fission products into primary coolant system. Since nuclear power plants have licensing limits for the release of volatile fission products to the environment (off-gas limits) detailed monitoring of the development of clad failure is necessary. In case of fuel rod failure a release of fission products into the primary coolant system arises. Fission gases accumulated in the free volume of a fuel rod escape through the clad defect. Water entering the fuel rod reacts with fission products, forming volatile chemical compounds. These may escape in a similar manner into the fission gases. Other compounds may dissolve and may be carried outside the fuel rod as dissolved species. Consequently, the distribution of these fission products, in the cross section of the fuel rod, is modified. An implementation of the maximum entropy gamma computed tomography technique is used to obtain such distributions in the area of the fuel rod ...

413

Thermoluminescence of irradiated RbCl and RbCl:Sn crystals  

International Nuclear Information System (INIS)

The thermoluminescence (TL) and emission of coloured RbCl and RbCl:Sn crystals are studied in the temperature range 300 to 560 K. The glow peaks responsible for F centres and tin centres in different valence states are identified using optical bleaching studies. The glow peaks are analysed using total curve fitting method and the kinetic parameters are determined. In moderately #gamma#-irradiated tin-doped RbCl crystals, the TL emission bands observed at 4.0, 3.6, and 2.2 eV are attributed to Sn"0, Sn"+, and Sn"- centers, respectively. A comprehensive energy level diagram depicting the various TL processes in these undoped and tin-doped RbCl crystals is proposed. (author).

414

Thermo-transferred thermoluminescence (TTTl) in potassium-yttrium double fluoride doped with terbium  

International Nuclear Information System (INIS)

This paper presents results of studying the thermo-transferred thermoluminescence (TTTl) phenomenon in potassium-yttrium double fluoride doped with terbium (K_2YF_5_:Tb) at different impurity concentrations (0.8%, 0.95% and 0.99%). Previously to study the TTTl phenomenon, structural characterization and chemical composition of the materials were determined. The structural studies were conducted using a scanning electron microscope; meanwhile, chemical composition was analyzed using energy dispersive X-ray spectroscopy. Thermoluminescence kinetics was studied irradiating the samples with "1"3"7Cs gamma rays as well as with "9"0Sr/"9"0Y beta rays, analyzing the glow curves by the deconvolution method for obtaining the kinetic parameters. (Author)

2011-02-01

415

The Effect of Contacts on the Counting Characteristics of Heavily Doped Normal-Type Cadmium-Telluride  

Science.gov (United States)

Cadmium telluride single crystals were grown heavily doped with chloride by the THM method. The resulting crystals were n-type with free carrier concentrations of the order of 10('12)/cm at room temperature. Hall effect studies revealed room temperature mobilities between 30 and 350 cm('2)/v-sec and resistivites between 2 x 10('3) and 10('4) ohm-cm. Studies were made of the gamma and alpha counting characteristics of these crystals with metal, metal-semiconductor, and metal-insulator electrodes. It was found that the MIS and MSS structures resulted in significant improvement over the MS structures in counting, signal-to-noise and energy resolution.

1985-01-01

416

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. The theory and ...

2001-01-01

417

Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information  

International Nuclear Information System (INIS)

The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)

2010-11-01

418

Radiation technology, radiation technics and technological dosimetry in the Institute of Isotopes of the Hungarian Academy of Sciences. 1966-1981  

Energy Technology Data Exchange (ETDEWEB)

Pilot-plant irradiation began in Hungary in 1969 with the construction of a high-activity multi-purpose /sup 60/Co facility. Technologies for radiation sterilization, food handling, plastics irradiation as well as chemical dosimetry, semiconductor instrumental dosimetry, computer-based construction and control methods have been developed. Our chlorobenzene dose-meter system is used in Hungary and abroad; as a result of an IAEA-organized dosimetric intercomparison the system was adopted as a reference system. The institute has developed into a basic institute for the reconstruction and re-load of old ..gamma..-facilities as well as it serves for the planning, construction and launching of new ones in Hungary.

1982-01-01

419

Radiation streaming analysis of horizontal penetrations in calandria vault of TAPP-3, 4  

International Nuclear Information System (INIS)

This paper consists the radiation streaming analysis of Horizontal penetrations in Calandria Vault of 540 MWe PHWR. There are total 19 penetrations, penetrating east and west walls of calandria vault of 540 MWe PHWR. These penetrations are provided to accommodate ion chambers. HFUs and SDS - 2. Penetrations described here are not present in 220 MWe units except for ion chamber penetrations. As these penetrations are in accessible area, a detailed analysis has been carried out to find out the neutron and gamma dose rates around these penetrations when reactor is operating. Analysis has been carried out using computer code DOT-III and MCNP. Predictions by this method compare well with the measurements at ion chamber locations at KGS-1,2. (author)

2006-11-13

420

Photoluminescence Decay of Irradiated Herbs  

Energy Technology Data Exchange (ETDEWEB)

Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt){sup -P}. The influence of both B and P factors upon the irradiation dose has been systematically analysed. (author)

1999-07-01

421

Photoluminescence Decay of Irradiated Herbs  

International Nuclear Information System (INIS)

Thermoluminescence of inorganic dust extract from herbs and spices has been demonstrated to be a useful method to discriminate irradiated food products as well as to estimate the total dose exposure. The time evolution of infrared stimulated luminescence has been systematically investigated in potassium feldspar and albite minerals subjected to different doses of gamma irradiation (ranging from 0 to 8 kGy). Experimental results reveal a 300-600 nm signal which is greatly intensified for irradiated samples, following the same irradiation dose dependence observed in thermoluminescence. The luminescence intensity disappears after few seconds of illumination, following a time evolution which is proportional to (1 + Bt)"-"P. The influence of both B and P factors upon the irradiation dose has been systematically analysed. (author)

1998-07-05

422

Nonlinear creep deformation analysis of a radiation-cured wood-polymer composite  

International Nuclear Information System (INIS)

A wood-polymer composite has been produced by impregnating the wood with the monomer and subsequently polymerizing it by exposure to a gamma radiation source. To compare the improvement in creep deformation of the wood due to the polymer impregnation, a nonlinear Norton-Bailey isothermal mathematical function has been used to model the bending creep deformation of the wood-polymer composites. Results show that the impregnation significantly improves the creep resistance of the wood. The maximum creep resistance is obtained when the amount of polymer impregnation exceeds about 30%. An interfacial interaction between the wood cell wall and the polymer could explain the creep deformation improvement, as well as the maximum impregnation level beyond which little improvement occurs. The results indicate that polymer impregnation is a viable method for improving the poor creep properties of wood. (author).

1989-01-01

423

Laparoscopic Transduodenal Ampullectomy for Benign Ampullary Tumors  

British Library Electronic Table of Contents (United Kingdom)

Abstract Introduction: Transduodenal ampullectomy (TDA) can be performed for benign and premalignant tumors of the ampulla of Vater (AOV) as an alternative to pancreaticoduodenectomy. However, the laparoscopic approach has rarely been attempted. In this report 2 cases of benign ampullary tumor that were treated by totally laparoscopic TDA. Patients and Methods: Case 1 was of a 75-year-old female who was admitted with left knee pain and underwent arthroscopic debridement. On postoperative day 6, she showed elevated levels of alkaline phosphatase, aspirate aminotransferase, alanine transaminase, and gamma-glutamyl transpeptidase, without any other laboratory test abnormality. She had no complaint of abdominal pain, and physical examinations were unremarkable. Computed tomography (CT), magnet...

2010-01-01

424

Irradiation of human insulin in aqueous solution, first step towards radiosterilization  

British Library Electronic Table of Contents (United Kingdom)

The degradation of irradiated human insulin in aqueous solutions was investigated in order to protect the protein against ionizing radiation. The influence of the drug concentration, excipients and irradiation temperature were studied.Aqueous solutions at pH 2 were irradiated by gamma rays or by accelerated electrons. Two different high-performance liquid chromatography (HPLC) methods were used: reverse-phase high-performance liquid chromatography (RP-HPLC)/UV and size exclusion liquid chromatography (SEC/UV) to investigate both the fragmentation and the formation of higher molecular weight proteins.In solution without excipients irradiated at ambient temperature at 10kGy, the loss of human insulin is almost complete. Addition of radio-protecting excipients (free radicals scavengers) and c...

2007-01-01

425

IAEA RESEARCH CONTRACTS FIRST ANNUAL REPORT. Technical reports Series No. 4  

Science.gov (United States)

Summaries are included of research contracts which expired prior to Dec. 31, 1960. The contracts were concerned with investigations of: electrophysiological responses of biological systems in nerve cells to irradiation with small doses of ionizing radiations; the mode of the protective action of certain sulfhydryl compounds against radiation effects on the synthesis of deoxyribonucleic acid, using tritium-labeled thymidine; development of a bubble chamber method of monitoring and dosimetry for Low fast neutron fluxes; effects of incorporated radioisotopes on the stability of genetic materials; interrelation of root and leaf absorption of radioisotopes in herbaceous plants; uptake of radioactive wastes by lowland rice from soils contaminated by irrigation water, and decontamination of the rice; and comparison between mutation rates induced by acute and chronic gamma irradiations. (B.O.G.)

1961-01-01

426

First measurement of ADS parameters using B- -> D0K- decays in hadron collisions  

CERN Document Server

Measurements of branching fractions and CP-asymmetries of B^{-} \\rightarrow D^{0}K^{-} modes allow a theoretically-clean extraction of the CKM angle \\gamma. The method proposed by Atwood, Dunietz and Soni (ADS) makes use of a decay chain where color and Cabibbo suppression interfere, which produces large CP-violating asymmetries. The CDF experiment reports the first measurement at a hadron collider of branching fractions and CP-asymmetries of suppressed B^{-} \\rightarrow D^{0}h^{-} signals, where h is \\pi or K. Using 5.0 fb^{-1} of data we found a combined significance exceeding 5\\sigma and we determined the ADS parameters with accuracy comparable with B-factories.

2011-01-01

427

Exact Simulation of Bessel Diffusions  

CERN Document Server

We consider the exact path sampling of the squared Bessel process and some other continuous-time Markov processes, such as the CIR model, constant elasticity of variance diffusion model, and hypergeometric diffusions, which can all be obtained from a squared Bessel process by using a change of variable, time and scale transformation, and/or change of measure. All these diffusions are broadly used in mathematical finance for modelling asset prices, market indices, and interest rates. We show how the probability distributions of a squared Bessel bridge and a squared Bessel process with or without absorption at zero are reduced to randomized gamma distributions. Moreover, for absorbing stochastic processes, we develop a new bridge sampling technique based on conditioning on the first hitting time at zero. Such an approach allows us to simplify simulation schemes. New methods are illustrated with pricing path-dependent options.

2009-01-01

428

Electronic structure and superconductivity of europium  

International Nuclear Information System (INIS)

We have calculated the electronic structure of Eu for the bcc, hcp, and fcc crystal structures for volumes near equilibrium up to a calculated 90 GPa pressure using the augmented-plane-wave method in the local-density approximation. The frozen-core approximation was used with a semi-empirical shift of the f-states energies in the radial Schroedinger equation to move the occupied 4f valence states below the #GAMMA#_1 energy and into the core. This shift of the highly localized f-states yields the correct europium phase ordering with lattice parameters and bulk moduli in good agreement with experimental data. The calculated superconductivity properties under pressure for the bcc and hcp structures are also found to agree with and follow a T_c trend similar to recent measurement by Debessai et al.

2010-09-01

429

Electronic properties of Nb_3Ge and Nb_3Al from self-consistent pseudopotentials. I. Band structure and density of states  

International Nuclear Information System (INIS)

The self-consistent-pseudopotential method is applied to the A-15 compounds Nb_3Ge and Nb_3Al. The Fermi energy is found to lie in a region of very flat bands having a bonding character along the Nb chains. Comparison with the band structures of the (nonexistent) A-15 materials Nb_3Nb and Nb_3/sup asterisk/ (chains only) suggest that the p states on the Ge and Al atoms are instrumental in determining the position of the Fermi level. There is little evidence for rigid-band behavior in the Nb_3Al/sub x/Ge/sub 1-x/ system. Studies of the effects of chain dimerization in Nb_3Ge suggest that states at R and M are more likely candidates to participate in structural transitions than states at GAMMA or X.

430

Anatomical Description of the Female Reproductive Organ and Radiation Induced Histological changes of Ovary of Melon fly, Bactrocera cucurbitae (Coq.) (Diptera: Tephritidae)  

International Nuclear Information System (INIS)

Application of gamma radiation as a physical method of disinfestations against melon flies was recognized as a potential quarantine treatment. At 50 Gy, oocytes showed degeneration one day after treatment whereas seven-day-old oocytes did not differ greatly in appearance from control groups. Abnormal enlargement of trophocyte cells and vacuolization of oocytes occurred predominantly following the treatment with 100 and 150 Gy. One day after treatment with 150 Gy trophocytes underwent hypertrophy and hyperplasia. Irradiation at 100 and 150 Gy reduced the fertility to almost zero percent in the female melon flies.(authors)

2006-06-01

431

Teleobservation in hostile environment  

International Nuclear Information System (INIS)

In order to meet the needs of remote servicing performed in nuclear power plants, in fuel reprocessing plants and in atomic research centers three companies: - STMI, subsidiary of CEA, EDF and SGN, specialized in decontamination and dismantling, - La Calhene, subsidiary of CEA and SGN, specialized in robotics, - Inspectronic, manufacturer of closed circuit television cameras, have combined to create the Visionic Society, the main objectives of which are observation by television and inspections in radioactive environment.

432

Solar Eclipse Images - SDAC Home Page - NASA  

Science.gov (United States)

Oct 24, 1995 ... The photos were made with a Nikon FE and a Sigma 400mm APO f/5.6 lens ... Note: The JPEG images to which the above links point contain subtle ... India on 1995 October 24 with a digital camera and Fe X 6374 ? filter, ...

433

Measurements of nuclear emulsion tracks by means of a picture analysis system  

Energy Technology Data Exchange (ETDEWEB)

A semiautomatic system for measurements of nuclear tracks in nuclear emulsion is described. The microscopic image of a particle track is picked up by a video camera. The video picture is digitized in real time. The picture analysis is done via software. The microscope is equipped with a stepping motor driven stage which is also computer-controlled.

1986-01-01

434

CORONAL OBSERVATIONS OF CMEs Report of Working Group A  

Science.gov (United States)

imaging of the solar corona began in 1960 via a primitive pinhole camera on a ... IR wavelengths. Such data help us to study in detail the pre-eruptive ...... Schematic picture of flare loops, CME, and the current sheet between ..... As part of NASA's Living With a Star (LWS) program the planned Sentinel mission ...

435

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and the variations in ...

1984-06-05

436

Application of remote sensing for coal waste embankment monitoring  

Energy Technology Data Exchange (ETDEWEB)

The Bureau of Mines has two projects in the remote sensing field as it pertains to mining. One of these is a completed contract that studied the use of aircraft mounted cameras and the results of photogrammetry. The second project is an ongoing contract to study the effectiveness of using an instrumentation system wired to remote data collection station to record embankment data. 6 refs.

1981-01-01

437

AERONAUTICAL ENGINEERING - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Topics addressed include future trends in IR sensors, IR observer performance modeling ... steer a sensor platform with a thermal camera or an air-to-air missile system. .... Skyship and Sentinel series airships. It also outlines the current .... A layout schematic of the UPS is given. AIAA. A93-55494 ...

438

\\psi(2S) Decays into $\\J$ plus Two Photons  

CERN Document Server

Using $\\gamma \\gamma J/\\psi, J/\\psi \\ra e^+ e^-$ and $\\mu^+ \\mu^-$ events from a sample of $14.0\\times 10^6$ $\\psip$ decays collected with the BESII detector, the branching fractions for $\\psip\\ra \\pi^0\\J$, $\\eta\\J$, and $\\psi(2S)\\ar\\gamma\\chi_{c1},\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi$ are measured to be $B(\\psip\\ra \\pi^0\\J) = (1.43\\pm0.14\\pm0.13)\\times 10^{-3}$, $B(\\psip\\ra \\eta\\J) = (2.98\\pm0.09\\pm0.23)%$, $B(\\psi(2S)\\ar\\gamma\\chi_{c1}\\ar\\gamma\\gamma\\jpsi) = (2.81\\pm0.05\\pm 0.23)%$, and $B(\\psi(2S)\\ar\\gamma\\chi_{c2}\\ar\\gamma\\gamma\\jpsi) = (1.62\\pm0.04\\pm 0.12)%$.

2004-01-01

439

Role of interferon-gamma in interleukin 12-induced pathology in mice.  

UK PubMed Central (United Kingdom)

Interleukin 12 (IL-12) activates natural killer (NK) and T cells with the secondary synthesis and release of interferon-gamma (IFN-gamma) and other cytokines. IL-12-induced organ alterations are reported...Full Text Available

1995-12-01

440

Response of heifer mammary gland macrophages and neutrophils to interferon-gamma stimulation in vitro.  

UK PubMed Central (United Kingdom)

The phagocytic and killing abilities of heifer mammary gland macrophages (M phi) and neutrophils were evaluated after exposure to recombinant bovine interferon-gamma (rBoIFN-gamma) stimulation in vitro....Full Text Available

1993-07-01

441

On the decay of "2"0"3Bi  

International Nuclear Information System (INIS)

The radioactive decay of "2"0"3Bi is studied. A level scheme is proposed for "2"0"3Pb on the basis of #gamma#-ray and electron spectra and #gamma#-#gamma# coincidence measurements. The experimental data are compared with theoretical results obtained in a three quasiparticle approximation. (Auth.).

442

Measurements of the CKM angle $\\gamma/\\phi_{3}$ at B-factories  

CERN Document Server

The CKM angle $\\gamma/\\phi_{3}$ had been measured by two B-factories, the PEPII collider for the BaBar experiment and the KEKB collider for the Belle experiments. The present paper reports recent progress in $\\gamma/\\phi_{3}$.

2011-01-01

443

Isolation and characterization of a novel gamma-hexachlorocyclohexane-degrading bacterium.  

UK PubMed Central (United Kingdom)

The natural biotic capacity of soils to degrade gamma-hexachlorocyclohexane (gamma-HCH, lindane) was estimated using an enrichment technique based on the ability of soil bacteria to develop on synthetic...Full Text Available

1996-10-01

444

Cloning and sequencing of a dehalogenase gene encoding an enzyme with hydrolase activity involved in the degradation of gamma-hexachlorocyclohexane in Pseudomonas paucimobilis.  

UK PubMed Central (United Kingdom)

In Pseudomonas paucimobilis UT26, gamma-hexachlorocyclohexane (gamma-HCH) is converted by two steps of dehydrochlorination to a chemically unstable intermediate, 1,3,4,6-tetrachloro-1,4-cyclohexadiene...Full Text Available

1993-10-01

445

Pair production of charged top-pions in the $\\gamma\\gamma$ collisions at the ILC  

CERN Document Server

The top-color assisted technicolor (TC2) mode predicts the existence of a pair of charged top-pions $\\pi^{\\pm}_t$. In this paper, we study the production of the charged top-pions pair $\\pi^{\\pm}_t$ at next generation $\\gamma\\gamma$ colliders. The results show that the production rates can reach the level of $10^2$ fb with reasonable parameter space. With a large number of events and the clean background, the charged top-pion should be observable at the $\\gamma\\gamma$ colliders. Therefore, our studies can help us to search for charged top-pion, and furthermore, to test the TC2 model.

2011-01-01

446

High intensity lasers for gamma-gamma colliders  

International Nuclear Information System (INIS)

Compton backscattering of laser photons near the interaction point of an e"+e"- or e"-e"- collider can be used to produce a #gamma#-#gamma# or #gamma#-e"- collider. This paper describes the laser requirements, including pulse duration, intensity, energy, and wavelength, for such a collider. For most of the proposed, next generation, e"+e"- colliders, the laser wavelength should be in the near-infrared, with a pulse duration of 1 ps or less and an energy of similar 1 J per pulse. Current chirped pulse amplification laser systems in solid state lasing materials are well suited to meet these requirements. These systems are described. ((orig.)).

447

Heavy quark production in $\\gamma\\gamma$ collisions a theoretical reappraisal  

CERN Document Server

Heavy quark production in $\\gamma\\gamma$ collisions is analyzed within the approach to hard collisions of photons recently proposed by the author. In this approach evaluating the cross section $\\sigma(\\gamma\\gamma\\to Q\\bar{Q})$ in the ``next-to-leading order of QCD'' requires the inclusion of direct photon contributions up to the order $\\alpha^2\\alpha_s^2$, whereas in the standard approach direct photon terms only up to the order $\\alpha^2\\alpha_s$ are taken into account. Phenomenological consequences of this difference are discussed.

2000-01-01

449

Semihard production of neutral pseudoscalar and tensor mesons in photon-photon collisions  

Energy Technology Data Exchange (ETDEWEB)

We investigate the semihard production of neutral pseudoscalar and tensor mesons in high-energy [gamma][gamma] collisions (M=P=[pi][sup 0], [eta], [eta]' or M=T=a[sub 2], f[sub 2], f[sub 2]'). We deal with the exclusive [gamma][gamma][yields]MM' or semi-exclusive [gamma][gamma][yields]MX reactions (X is the hadron jet with not too large mass). The considered transfer momenta are small in comparison with the photon energies and they are large in comparison with the confinement scale. The amplitudes of these processes are determined by the odderon exchange, i.e. three-gluon exchange in the lowest order of perturbative QCD. The cross sections are calculated in this approximation. The possibility of measurements at LEP and at future [gamma][gamma] colliders is discussed. (orig.).

1992-12-21

450

Radiation deamination of tetracycline. [Gamma radiation  

Energy Technology Data Exchange (ETDEWEB)

The fundamental product of tetracycline hydrochlorine gamma radiolysis was separated in its solid state. From the results of spectroscopic studies it has been established that it is des-N,N-dimethylaminotetracycline.

1980-01-01

451

Production of doubly charged vector bilepton pairs at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

The production of pairs of doubly charged vector bileptons is studied at future #gamma##gamma# colliders. The unpolarized cross section for the #gamma##gamma##->#Y"-"-Y"+"+ subprocess is analytically calculated and convoluted to predict the number of events in the complete e"+e"-#->##gamma##gamma##->#Y"-"-Y"+"+ process. The gauge or nongauge character of the vector bilepton Y"#+-#"#+-# is discussed. It is found that, as a consequence of its spectacular signature, as it decays dominantly into two identical charged leptons, and also due to its charge contents, which significantly enhance the cross section, the detection of this class of particles with mass in the sub-TeV region can be at the reach of these colliders. The model-independent nature of our results is stressed.

2006-05-01

452

On penetration effect in M1 component of 70.45 keV #gamma#-transition in "1"7"7Ta  

International Nuclear Information System (INIS)

... gamma radiation l conversion m conversion mev range 10-100 mixing ratio

1987-04-14

453

Il package software GESIS per la gestione di sistemi spettrometrici gamma  

CERN Document Server

Il package software GESIS per la gestione di sistemi spettrometrici gamma

1986-01-01

454

Gamma-spectroscopy of "6"4Mn_3_9 and "6"6Mn_4_1 decays  

International Nuclear Information System (INIS)

... v. 33(4). beta-minus decay de-excitation delayed gamma radiation iron 64

455

GAMMA SPECTRA AND PERIODS OF FOUR ODD-A ISOTOPES OF TUNGSTEN AND TANTALUM  

Science.gov (United States)

The gamma spectra and lifetimes of the Ta and W isotopes havimg mass numbers 173, 175, 177, and 179 are determined. (T.F.H.)

1963-06-01

457

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures  

CERN Document Server

Determination of absorbed dose in a patient irradiated by beams of x or gamma rays in radiotherapy procedures

1976-01-01

458

Comparison of the BUGLE-80 and SAILOR libraries for coupled neutron-gamma transport applications  

International Nuclear Information System (INIS)

The coupled neutron-gamma cross section libraries BUGLE-80 and SAILOR are compared, with focus on gamma production and transport and its sensitivity to the thermal component of the neutron flux. In addition, the importance of the prompt versus delayed components of the gamma source is addressed. Although BUGLE-80 shows some discrepancies in the core region, the two libraries demonstrate similar capability in the vicinity of the pressure vessel and beyond. The delayed fission product gammas from the core have little impact on the local gamma fluxes beyond the pressure vessel. Although thermal neutron capture is the dominant component of the gamma source, there is little sensitivity of the gamma source to uncertainties in the thermal neutron cross sections, due to compensating effects which tend to keep the thermal neutron capture rate ...

461

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The collimator may be a hollow cylinder positioned so that its central axis is perpendicular to the upper ...

2003-03-04

462

Estimation of a stress field in the earth`s crust using drilling-induced tensile fractures observed at well WD-1 in the Kakkonda geothermal field; Kakkonda WD-1 sei de kansokusareta drilling induced tensile fracture ni yoru chikaku oryokuba no suitei  

Energy Technology Data Exchange (ETDEWEB)

This paper describes estimation of a stress field in the earth`s crust in the Kakkonda geothermal field. Formation micro imager (FMI) logging known as a crack detecting logging was performed in the well WD-1. This FMI logging has made observation possible on cracks along well axis thought to indicate size and direction of the crust stress, and drilling-induced tensile fractures (DTF). It was verified that these DTFs are generated initially in an azimuth determined by in-situ stress (an angle up to the DTF as measured counterclockwise with due north as a starting point, expressed in {theta}) in the well`s circumferential direction. It was also confirmed that a large number of cracks incline at a certain angle to the well axis (an angle made by the well axis and the DTF, expressed in {gamma}). The DTF is a crack initially generated on well walls as a result of such tensile stresses as mud pressure and thermal stress acting on the well walls during well excavation, ...

1997-05-27

463

Development of functional foods for radiation workers - Search for the active components and studies on the mechanism of the hematopoiesis improvement foods  

Energy Technology Data Exchange (ETDEWEB)

In this experiments, we established long-termed culture methods of bone marrow stromal cells for proliferation and differentiation of stem cells. And we selected some extracts which support maximal proliferation of stromal cells with this method. We conformed the synergic effects of herbal mixture extracts for stromal cell growth. The proliferation of stromal cells was increased rather by the addition of mixture extracts than by addition of single strain extract. In the previous and cooperative experiments, we selected complex extracts (Him-I, Him-II) which increased the number of nonadherent mononuclear cells. Different cytokine expression patterns were observed stromal cells cultured in the presence or absence of mixture extracts which support differentiation of nonadherent cells. Some fractions of Him-I and Him-II increased the proliferation of bone marrow cells irradiated {gamma}-ray(4Gray). Stimulation of macrophage ...

2000-04-01

464

Determination of sodium in biological samples by instrumental neutron activation analysis  

International Nuclear Information System (INIS)

Sodium is one of the most essential elements needed for metabolic processes amongst human beings. It is consumed in the form of sodium chloride but it is also present in edible plant leaves. Sodium is mostly analyzed by flame photometric method, a destructive and time consuming technique. Sodium has been determined in some green leave vegetables samples-palak, radish, khatta palak (ambat chuka), chaulai leaves, chauli bean covers and its seeds by instrumental neutron activation analysis. The method involves irradiation of samples with thermal neutrons from "2"4"1Am-Be source and counting "2"4Na activity (half life 15 hr) from the reaction "2"3Na(n,#gamma#) "2"4Na. Activity due to 1.37 MeV photopeak was counted with a NaI(Tl) crystal coupled to gamma ray spectrometer. Green leaves of the vegetables were thoroughly washed, dried at constant temperature and powdered. Bowen's Kale powder was used as ...

1981-05-01

465

DNA rearrangements from #gamma#-irradiated normal human fibroblasts preferentially occur in transcribed regions of the genome  

International Nuclear Information System (INIS)

Full text: DNA rearrangement events leading to chromosomal aberrations are central to ionizing radiation-induced cell death. Although DNA double-strand breaks are probably the lesion that initiates formation of chromosomal aberrations, little is understood about the molecular mechanisms that generate and modulate DNA rearrangement. Examination of the sequences that flank sites of DNA rearrangement may provide information regarding the processes and enzymes involved in rearrangement events. Accordingly, we developed a method using inverse PCR that allows the detection and sequencing of putative radiation-induced DNA rearrangements in defined regions of the human genome. The method can detect single copies of a rearrangement event that has occurred in a particular region of the genome and, therefore, DNA rearrangement detection does not require survival and continued multiplication of the affected cell. Ionizing radiation-induced DNA ...

2003-08-17

466

Concepts in radiation protection  

International Nuclear Information System (INIS)

This monograph provides basic notions and principles in dosimetry and radiation protection in compliance with two fundamental works: IAEA Safety Series No.115 - International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources - and Publication no. 60 of International Commission on Radiological Protection. After the review of quantities and units necessary in radiation protection, the book presents the new values of dose limits as well as the values of 'radiation weighting factor', 'tissue weighting factor' and 'conversion factor intake-dose' (committed effective dose per unit intake) by ingestion and inhalation for 30 most important radionuclides. The new values of dose limits, lower than the old values, are a challenge for the radiation protection, especially of the 'public' where the dose limit diminished by a factor of five relative to the earlier edition. The new value of dose limit for public, 1 mSv per year (obviously over the ...

1996-01-01

467

Standardization of "2"4"1Am by digital coincidence counting, liquid scintillation counting and defined solid angle counting  

International Nuclear Information System (INIS)

The nuclide "2"4"1Am decays by alpha emission to "2"3"7Np. Most of the decays (84.6%) populate the excited level of "2"3"7Np with energy of 59.54 keV. Digital coincidence counting was applied to standardize a solution of "2"4"1Am by alpha-gamma coincidence counting with efficiency extrapolation. Electronic discrimination was implemented with a pressurized proportional counter and the results were compared with two other independent techniques: Liquid scintillation counting using the logical sum of double coincidences in a TDCR array and defined solid angle counting taking into account activity inhomogeneity in the active deposit. The results show consistency between the three methods within a limit of a 0.3%. An ampoule of this solution will be sent to the International Reference System (SIR) during 2009. Uncertainties were analysed and compared in detail for the three applied methods.

2009-09-07

468

Development of radiological emergency preparedness and biological dosimetry technology  

Energy Technology Data Exchange (ETDEWEB)

Large-scale field tracer experiments have been conducted on Ulchin and Wolsung nuclear sites for the purpose of validating FADAS and of analyzing the environmental characteristics around the nuclear site. The most influential factor in atmospheric dispersion is the meteorological condition. During the experiment, meteorological data were measured on the release point and the selected positions among sampling points. Once radioactive materials are released to the atmosphere, members of public may be exposed through the environmental media such as air, soil and foods. Therefore, to protect the public, adequate countermeasures should be taken at due time for those exposure pathways. Both processes of justification and optimization are applied to a countermeasure simultaneously for decision-making. The work scope of biological research for the radiation protection had contained the search of biological microanalytic methods for the assessment of health effect by ...

1999-04-01

469

Decoupling of uranium metal with borated plaster using /sup 252/Cf nose analysis methods  

Energy Technology Data Exchange (ETDEWEB)

The use of borated plaster to isolate uranium (93.2 wt % /sup 235/U) metal was studied in a series of subcritical experiments with uranium metal cylinders (7.0 in. diam, 2.0 in. thick) and slabs (approx.1.4 x approx.5.4 x approx.10.1 in. dimensions). In the cylindrical experiments, the thickness of borated plaster was varied up to 10 in. and the subcriticality measured using the /sup 252/Cf-source-driven neutron noise analysis method. In the experiments with the uranium slabs, an array of slabs 3 wide and 8 high was assembled in steps to demonstrate the subcriticality of this array with 3.75-in.-thick borated plaster as an isolating material between all uranium slabs. In the slab experiments, both noise analysis and source neutron multiplication measurements were performed. Before assembly of the slab array the presence of boron in the plaster was verified by neutron transmission and gamma-ray spectrometry measurements.

1985-01-01

470

Adaptation of a cubic smoothing spline algortihm for multi-channel data stitching at the National Ignition Facility  

Energy Technology Data Exchange (ETDEWEB)

Some diagnostics at the National Ignition Facility (NIF), including the Gamma Reaction History (GRH) diagnostic, require multiple channels of data to achieve the required dynamic range. These channels need to be stitched together into a single time series, and they may have non-uniform and redundant time samples. We chose to apply the popular cubic smoothing spline technique to our stitching problem because we needed a general non-parametric method. We adapted one of the algorithms in the literature, by Hutchinson and deHoog, to our needs. The modified algorithm and the resulting code perform a cubic smoothing spline fit to multiple data channels with redundant time samples and missing data points. The data channels can have different, time-varying, zero-mean white noise characteristics. The method we employ automatically determines an optimal smoothing level by minimizing the Generalized Cross Validation (GCV) score. In ...

2010-12-28

471

Versatile gamma scanning system  

International Nuclear Information System (INIS)

(Feb 1972). United States Swinth, KL Weber, JW San Francisco, Calif.

474

Production of MSSM Higgs bosons in #gamma##gamma# collisions  

International Nuclear Information System (INIS)

The heavy Higgs bosons H,A of the minimal supersymmetric extension of the Standard Model can be produced as resonances in high-energy #gamma##gamma# colliders. Prospects of the search for these particles in bb-bar and neutralino-pair final states are studied in this report. Heavy Higgs bosons can be found with masses up to about 70-80% of the initial e"+e"- collider energy for moderate values of tan #beta#, i.e. in areas of the parameter space not accessible at other colliders.

2001-10-11

475

Production of MSSM Higgs bosons at future #gamma##gamma# colliders  

International Nuclear Information System (INIS)

Future #gamma##gamma# colliders allow the production of the heavy neutral MSSM Higgs bosons H and A as single resonances. The prospects of finding these particles in the bb-bar and the neutralino-pair final states have been analyzed. The H, A bosons can be discovered for medium values of tan #beta# with masses up to 70-80% of the initial e"#+-#e"- c.m. energy. This production mode thus covers parts of the supersymmetric parameter space that are not accessible at other colliders.

2001-07-09

476

Probing Neutron Star Evolution with Gamma Rays  

Science.gov (United States)

The research sponsored by this grant was conducted in two fields of high-energy astrophysics:

1996-01-01

477

POTENTIATION BY PENTOBARBITAL OF THE PROTECTIVE ...  

Science.gov (United States)

... Accession Number : AD0268549. Title : POTENTIATION BY PENTOBARBITAL OF THE PROTECTIVE EFFECT OF AET AGAINST GAMMA RAYS. ...

1961-10-01

478

New physics effects on Higgs production at #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We study heavy physics effects on the Higgs production in #gamma##gamma# fusion using the effective Lagrangian approach. We find that the effects coming from new physics may enhance the standard model predictions for the number of events expected in the final states b-barb, WW, and ZZ up to one order of magnitude, whereas the corresponding number of events for the final state t-bart may be enhanced up to two orders of magnitude.

1996-02-20

480

Heavy charged Higgs boson production at next generation {gamma}{gamma} colliders  

Energy Technology Data Exchange (ETDEWEB)

We investigate the scope of all relevant production modes of charged Higgs bosons in the MSSM, with mass larger than the one of the top quark, at future Linear Colliders operating in {gamma}{gamma} mode at the TeV energy scale. Final states with one or two H{sup {+-}} bosons are considered, as produced by both tree- and loop-level interactions. (orig.)

2003-07-01

481

Heavy charged Higgs boson production at next generation #gamma##gamma# colliders  

International Nuclear Information System (INIS)

We investigate the scope of all relevant production modes of charged Higgs bosons in the MSSM, with mass larger than the one of the top quark, at future Linear Colliders operating in #gamma##gamma# mode at the TeV energy scale. Final states with one or two H"#+-# bosons are considered, as produced by both tree- and loop-level interactions. (orig.)

2003-07-01

484

Gamma-ray spectra from neutron capture on /sup 87/Sr  

Energy Technology Data Exchange (ETDEWEB)

The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.

1981-07-01

485

Gamma ray detecting device using dislocation-free crystal  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.

1991-04-30

486

Free radicals in lysozyme reacted with peroxidizing methyl linoleate  

International Nuclear Information System (INIS)

... electron spin resonance gamma radiation lipids lyophilization lysozyme radicals

487

Four-fermion production at {gamma}{gamma} colliders: 1. Lowest-order predictions and anomalous couplings  

Energy Technology Data Exchange (ETDEWEB)

We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes {gamma}{gamma}{yields}4f and {gamma}{gamma}{yields}4f{gamma} in the standard model and extensions thereof by an effective {gamma}{gamma}H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes {gamma}{gamma}{yields}4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size ...

2004-08-01

488

Four-fermion production at #gamma##gamma# colliders: 1. Lowest-order predictions and anomalous couplings  

International Nuclear Information System (INIS)

We have constructed a Monte Carlo generator (the corresponding FORTRAN code can be obtained from the authors upon request) for lowest-order predictions for the processes #gamma##gamma##->#4f and #gamma##gamma##->#4f#gamma# in the standard model and extensions thereof by an effective #gamma##gamma#H coupling as well as anomalous triple and quartic gauge-boson couplings. Polarization is fully supported, and a realistic photon beam spectrum can be taken into account. For the processes #gamma##gamma##->#4f all helicity amplitudes are explicitly given in a compact form. The presented numerical results contain, in particular, a survey of cross sections for representative final states and their comparison to results obtained with the program package Whizard/Madgraph. The impact of a realistic beam spectrum on cross sections and distributions is illustrated. Moreover, the size of ...

2004-08-01

490

Diquarks in gamma-p Collisions at LHeC  

CERN Document Server

This note studies the single production of scalar or vector diquarks at the LHeC collider.

2011-01-01

491

Development of a real-time, neutron and gamma dosimeter  

Energy Technology Data Exchange (ETDEWEB)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-07-01

492

Development of a real-time, neutron and gamma dosimeter  

International Nuclear Information System (INIS)

In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)

2001-06-10

494

Carbide transformations in a gamma/gamma-prime nickel alloy during prolonged aging  

Energy Technology Data Exchange (ETDEWEB)

Carbide reactions occurring in a precipitation-hardening gamma/gamma-prime Ni-Cr alloy during prolonged high-temperature aging are investigated experimentally. It is found that the decomposition of primary MC carbides, which is accompanied by the precipitation of M23C6 particles, may lead to void nucleation and growth. The effect of carbide transformations on the residual properties of the material at temperatures above the equicohesion temperature is observed at the late stages of aging only. 6 references.

1988-08-01

497

A Leptonic-Hadronic Model for the Afterglow of Gamma-Ray ...  

Science.gov (United States)

... PHYSICS ATOMIC AND MOLECULAR PHYSICS AND SPECTROSCOPY NUCLEAR PHYSICS & ELEMENTARY PARTICLE PHYSICS. ...

2010-11-20

498

Low-lying states of {sup 109}Sn from the {sup 106}Cd({alpha},n{gamma}) reaction  

Energy Technology Data Exchange (ETDEWEB)

Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.

1999-02-01