WorldWideScience
1

Follow-up and diagnosis of recurrences after radio-chemotherapy of malignant head and neck tumors  

International Nuclear Information System (INIS)

339 CT und 95 MRT examinations in 210 partients were evaluated retrospectively to determine the value of CT and MRT for follow-up of head and neck tumors and for diagnosing recurrences. Semi-quantitative evaluation of tumor extent during and after radiotherapy showed advantages for MRT since changes induced by treatment, particularly oedema, produced less contrast loss in the images. CT had a sensitivity of 81% for the recognition of recurrences; this was 92% for MRT. Specificity for CT was 76% and for MRT 86%. Concerning the reliability of individual diagnostic criteria, space occupying lesions were the most valuable in CT diagnosis. For MRT, space occupying lesions and infiltration into neighbouring structures were of equal value. Because of differences in the nature of the signals, MRT proved better than CT in ...

2

Nephrogenic systemic fibrosis after application of gadolinium-based contrast agents - a status paper; Nephrogene systemische Fibrose nach Anwendung gadoliniumhaltiger Kontrastmittel - ein Statuspapier zum aktuellen Stand des Wissens  

Energy Technology Data Exchange (ETDEWEB)

Recently the association of a rare disease named ''nephrogenic systemic fibrosis'' (NSF) with the administration of gadolinium-containing contrast media, especially gadodiamide (Omniscan, GE-Healthcare), was described. NSF is a scleroderma-like disease characterised by widespread tissue fibrosis. Until now, NSF cases were observed only in patients with kidney disease. Almost all patients were suffering from chronic renal insufficiency, 90 % of them required renal replacement therapy. The true incidence of the disease is unknown. First retrospective analyses of selected collectives of patients with end-stage renal disease showed 2 - 5 % cases of NSF after administration of Gadolinium-containing contrast agents with an odds ratio of 20 - 50 in comparison to non-exposed controls. NSF is a serious adverse reaction, which may result in severe disabilities and even death. ...

2007-06-15

3

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE)  

International Nuclear Information System (INIS)

T_2 weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T_E=90 ms, T_R=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, contrast is ...

4

Magnetic resonance imaging in acute intractional tuberculosis; Magnetresonanztomographie bei akuter intrakranieller Tuberkulose  

Energy Technology Data Exchange (ETDEWEB)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.) [Deutsch] Die Befunde von drei Patienten mit intrakranieller Tuberkulose (intrakranielle Miliartuberkulose, Meningitis tuberculosa, Neuritis und Tuberkulome) in der Magnetresonanztomographie (MRT) wurden mit der Computertomographie (CT) verglichen. Sowohl die MRT als auch die CT wurden nativ und nach Kontrastmittelgabe durchgefuehrt. Die MRT zeigte sich im Nachweis von Granulomen insbesondere im Bereich des Hirnstamms ...

1994-12-31

5

Characteristic features of intracranial meningiomas on magnetic resonance tomography  

International Nuclear Information System (INIS)

Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).

6

MRT in differentiation between tumour and implant material in the postoperative sella. Differenzierung zwischen Tumor und Implantatmaterial in der postoperativen Sella mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T[sub 1] weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is ...

1993-06-01

7

A new application of MRT of the lung using ultra-shot turbo spin echo sequences (UTSE); Ein neuer Ansatz in der Magnetresonanztomographie der Lunge mit einer ultrakurzen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

T{sub 2} weighted ultra-short turbo spin echo sequences were used in five individuals with variations in echo times, delayed triggering and echo intervals. To reduce movement artifacts all examinations were carried out with ECG and respiratory triggering. The sequences giving optimal image quality were then employed in 19 patients having various pulmonary abnormalities. Image resolutions, artifacts, image contrasts and diagnostic value were then judged by two observers and compared with CT. In the first study, a diastole-triggered UTSE sequence with the shortest echo proved optimal (T{sub E}=90 ms, T{sub R}=2-4 s, echo=9 ms, turbo factor=19). In the patient series studied, MRT was inferior to CT with regard to resolution and number of artifacts, but better in respect of contrast and diagnostic value. Using UTSE of the lung, MRT can produce images of good quality. Compared with CT, ...

1996-05-01

8

MRT in differentiation between tumour and implant material in the postoperative sella  

International Nuclear Information System (INIS)

MRT criteria have been developed to distinguish between tumour and implant material following examination of 50 patients who had transsphenoidal hypophysectomies for tumours. Judgements were based on the postoperative hormonal status and the operation notes. Following contrast injection of Gd-DTPA and using T_1 weighted spin-echo sequences, implant material appeared as sandwich-like, linear or circular structures. Residual recurrent tumour produced homogenous or non-homogenous aspects without marginal enhancement in 84% of cases. Postoperative displacement of the infundibulum to the opposite side was observed in 73% of patients with tumour remnants. Sensitivity of MRT was 70%, specificity 95%. There was a positive predictive value of 94% and a negative predictive value of 72% with an accuracy of 81%. This provides assistance in differentiating between tumour remnants and implant material. MRT is ...

9

MRT of the abdomen in combination with enteroclysis in Crohn disease with oral and intravenous Gd-DTPA; MRT des Abdomens in Kombination mit der Enteroklyse bei Morbus Crohn unter Verwendung von oralem und intravenoesem Gd-DTPA  

Energy Technology Data Exchange (ETDEWEB)

60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel contrast is optimal. The ...

1998-01-01

10

Gadolinium-containing phosphatidylserine liposomes for molecular imaging of atherosclerosis  

UK PubMed Central (United Kingdom)

Exteriorized phosphatidylserine (PS) residues in apoptotic cells trigger rapid phagocytosis by macrophage scavenger receptor pathways. Mimicking apoptosis with liposomes containing PS may represent...Full Text Available

2009-11-01

11

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle; CT und MRT erworbener Veraenderungen des Innenohrs und Kleinhirnbrueckenwinkels  

Energy Technology Data Exchange (ETDEWEB)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the ...

2003-03-01

12

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease; Einfluss von biphasischer Spiral-CT, nativer und eisenoxidverstaerkter MRT auf Therapie und Therapiekosten bei Patienten mit fokalen Leberlaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 hemangioma, 1 regenerative nodule) all modalities failed, causing ...

2000-03-01

13

Lacrimal gland masses on CT and MRI: a report of four cases; Raumforderungen der Traenendruese in CT und MRT am Beispiel von vier Faellen  

Energy Technology Data Exchange (ETDEWEB)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.) [Deutsch] In einem erweiterten Fallbericht wird ueber die vier grossen Entitaeten bei Traenendruesenraumforderungen berichtet (Lymphom, ...

1995-11-01

14

Dissection of the thoracic aorta - role of CT and MRT following aortic replacement  

International Nuclear Information System (INIS)

Dynamic CT and MRT were performed in 21 patients who had undergone prosthetic replacement of the aorta because of dissection of the thoracic aorta. There is no difference between MRI and dynamic CT in the demonstration of a persistent intimal flap, the formation of a thrombus and the assessment of the aortic diameter in patients who underwent surgery for thoraco-abdominal aortic dissection. MRI, however, is superior in the identification of the true and false lumen and the demonstration of the distal anastomotic site. The major advantages of MRI are that there is no need for intravenous contrast agents, that it is high sensitive to flow phenomena, and that it can demonstrate the aortic arch and the ascending aorta on sagittal oblique sections. The major disadvantages of MRI are the limited access to the patient during the procedure, and the inability to examine patients fitted with pacemakers or who are on assisted ventilation. Today, MRI is ...

15

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity; Moderne bildgebende Methoden bei der Diagnostik von Tumoren des Oropharynx und der Mundhoehle  

Energy Technology Data Exchange (ETDEWEB)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, ...

1996-11-01

16

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas; CT und MRT des erworbenen Cholesteatoms: Prae- und postoperative Bildgebung  

Energy Technology Data Exchange (ETDEWEB)

The role of high-resolution computed tomography (HRCT) and magnetic resonance imaging (MRI) in the diagnosis of preoperative and postoperative complications caused by acquired cholesteatomas will be described in this paper. The pre- and postoperative imaging of the temporal bone was performed with HRCT and MRI. HRCT and MRI were performed in the axial and coronal plane. MRI was done with T2 weighted and T1 weighted sequences both before and after the intravenous application of contrast material. All imaging findings were confirmed clinically or surgically. The preoperative cholesteatoma-caused complications depicted by HRCT included bony erosions of the ossicles, scutum, facial canal in the middle ear, tympanic walls including the tegmen tympani, and of the labyrinth. The preoperative cholesteatoma-caused complications depicted by MRI included signs indicative for labyrinthitis, and brain abscess. Postoperative HRCT depicted bony erosions caused by recurrent ...

2003-03-01

17

Cerebral and meningeal manifestations of AIDS: Sensitivity of CT and T sub 2 -weighted MR (129 patients). Zerebrale und meningeale Manifestation des AIDS: Sensitivitaet von CT und T sub 2 -gewichteter MRT (129 Patienten)  

Energy Technology Data Exchange (ETDEWEB)

We studied 129 AIDS patients with suspected or proved intracranial manifestations of the disease. The purpose of this study was to compare the diagnostic sensitivity of unenhanced and contrast enhanced CT and unenhanced T{sub 2}-weighted MR. Thus, in 20% of our patients MR but not CT was diagnostic. In another 20% MR provided additional diagnostic information. In conclusion, MR is recommended as the imaging modality of choice in AIDS patients with non-conclusive cranial CT. (orig./GDG).

1990-09-01

18

Value of contrast-enhanced MRI of breast after silicone implant; Wertigkeit der Kontrastmittelmagnetresonanztomographie der Mamma bei Wiederaufbau mittels Implantat  

Energy Technology Data Exchange (ETDEWEB)

Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases with indeterminate findings. However, due ...

1997-09-01

19

Benign diseases of the mandible in MRI; Benigne Erkrankungen des Unterkiefers im MRT  

Energy Technology Data Exchange (ETDEWEB)

Diseases of the mandible affect the soft tissues aside from the osseous manifestation. This can be shown clearly and in great detail by magnetic resonance imaging (MRI). MRI is the gold standard in the diagnostic evaluation of any internal derangement of the temporomandibular joint. Dental MRI requires high resolution techniques and in some cases also intravenous administration of contrast material. These techniques allow delineation of the neurovascular bundle. In the past few years new indications were formulated, for example, the evaluation of the integrity of the inferior alveolar nerve in trauma and in radicular cysts. New quantitative methods now enable insights into the pathophysiology. The objective of this review is to communicate accepted indications for MRI of the mandible and to present innovative applications. (orig.) [German] Mandibulaere Erkrankungen beteiligen neben dem Knochen Weichteilstrukturen, die sich mit der MRT klar und ...

2004-04-01

20

Modern visualization of the liver with MRI - current trends and future perspectives; Moderne Leberbildgebung mit der MRT - aktuelle Trends und Zukunft  

Energy Technology Data Exchange (ETDEWEB)

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto irrelevant problems must still be solved. Overall the innovations presented here, applied alone or in combination, facilitate ...

2004-12-01

21

MRI in combined subacute degeneration of the spinal cord; MRT bei funikulaerer Myelose  

Energy Technology Data Exchange (ETDEWEB)

The MRI morphology in combined subacute degeneration has only rarely been reported. We describe two patients suffering from subacute combined degeneration of the spinal cord on the basis of a deficiency of vitamin B{sub 12}. In both patients characteristic hyperintense areas on T{sub 2}-weighted images in the posterior columns of the cervical and thoracic cord without contrast enhancement were demonstrated by MRI. (orig.) [Deutsch] Bisher liegen zur wenige Beschreibungen der MR-Morphologie bei funikulaerer Myelose vor. Wir beschreiben zwei Patienten mit den klinischen Zeichen einer funikulaeren Myelose auf der Basis eines Vitamin B{sub 12}-Mangels. Bei beiden konnten mit der MRT charakteristische Signalanhebungen im T{sub 2}-gewichteten Bild in den Hinterstraengen des zervikalen und thorakalen Rueckenmarks gezeigt werden. Eine Kontrastmittelaufnahme war nicht nachweisbar. (orig.)

1999-06-01

22

Ganglioneuromas in childhood: MRI and CT characteristics; Ganglioneurome im Kindesalter: CT- und MRT-Charakteristika  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub 1}-weighted scans the tumors were homogeneous ...

2000-05-01

23

MRT of the abdomen in combination with enteroclysis in Crohn disease with oral and intravenous Gd-DTPA  

International Nuclear Information System (INIS)

60 patients between 17 and 72 years of age were investigated. First, an enteroclysis was performed in typical manner. The applicated methylcellulosis was blended with positive oral MR contrast media (Magnevist oral, Schering). After enteroclysis, MRI of the abdomen was performed using T1- and T2-weighted breathhold sequences (Flash 2D pre- and postcontrast and TSE) in axial and coronal planes. The length of the affected bowel and the stenosis seen with enteroclysis correlated well with the visible thickening of the small bowel wall and the stenosis seen in MRI. Using MRI, additional findings could be obtained in 28 patients, such as fistulas, abscesses or a hydronephrosis, or a better assessment of the stenosis was possible with MRI, because of the avoidance of overshadowing of the affected bowel loop with MRI. A brilliant MR-tomographic imaging of the small bowel is possible under the condition, that the small bowel contrast is optimal. The ...

24

New MR techniques in diagnostic imaging of joints; Neue MRT-Techniken in der Gelenkdiagnostik  

Energy Technology Data Exchange (ETDEWEB)

Already, MR Imaging is superior in diagnostic imaging of joints in many cases; however, there have been recent developments, which are the subjects of this paper. With gradient-echo sequences acquired in 3D technique, it is possible to produce high-resolution images of joints in acceptable scantime, because gradient-echo sequences are less time-consuming than convential SE sequences. With the acquisition of two echoes, phase difference between water and fat protons have to be considered. 3D Imaging is capable of displaying complex pathology in a superior way, which should be useful in preoperative planning. Tissue contrast is altered by fat saturation or magnetization transfer in order to achieve better conspicuity of lesions. Although diagnostic value of some of these options is not yet clear and further clinical studies are needed, they are a promising possibility for improving MR Imaging of the joints. (orig.) [Deutsch] In der Gelenkdiagnostik gibt es einige ...

1993-12-31

25

MRI in definition of bleeding source, lesion pattern and therapy in haemarthros of the knee; Die MRT beim Haemarthros des Kniegelenks: Bestimmung von Blutungsursachen, Verletzungsmustern und Therapie  

Energy Technology Data Exchange (ETDEWEB)

Patients with haemarthros of the knee were examined by MRI and arthroscopy to identify the bleeding source and to determine surgical or conservative therapy. A prospective study was performed on 120 patients who underwent MRI and arthroscopy, point lesions and bleeding sources were documented separately on a standardised form. Arthroscopy demonstrated a ruptured anterior cruciate ligament in 86%, meniscal tears in 55%, disruption of collateral ligaments in 17%, osteochondral lesions in 5% and tears of capsule or plicae in 13%. Disruption of cruciate ligaments caused haemorrhage in all but three cases. In contrast, only meniscal tears located very adjacent to the meniscal basement had bled. Those types of osteochondral lesions caused haemorrhage characterised on MRI by destruction of the subchondral plate and overlying cartilage. Severe lesions of the knee were diagnosed by MRI in 71% to 100%, slight lesions in 13% to 40% of the cases. Single, combined and bland ...

1996-09-01

26

Dura thickening adjacent to intracranial tumors on MRI. Histologically correlation; Duraverdickung am Rand intrakranieller, duranaher Raumforderungen in der MRT. Histologische Korrelation  

Energy Technology Data Exchange (ETDEWEB)

Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T{sub 2}-weighted spin echo (SE) images as well as T{sub 1}-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base ...

1997-11-01

27

Diagnosis of plasmocytomas using magnetic resonance imaging; Diagnostik des Plasmozytoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse ...

2000-08-01

28

CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontine angle; CT und MRT tumoroeser Veraenderungen des Schlaefenbeins  

Energy Technology Data Exchange (ETDEWEB)

Tumours lesions of the temporal bone and of the cerebello-pontine angle are rare.This tumours can be separated into benign and malignant lesions. In this paper the CT and MRI characteristica of tumours of the temporal bone and the cerebello-pontane angle will be demonstrated. High resolution CT (HRCT) as usually performed in the axial plane are using a high resolution bone window level setting, coronal planes are the reconstructed from the axial data set or will be obtained directly. With the MRI FLAIR sequence in the axial plane the whole brain will be scanned either to depict or exclude a tumour invasion into the brain. After this,T2-weighted fast spin echo sequences or fatsuppressed inversion recovery sequences in high resolution technique in the axial plane will be obtained from the temporal bone and axial T1-weighted spinecho sequences before and after the intravenous application of contrast material will be obtained of this region. Finally T1-weighted ...

2003-03-01

29

3D MRI of the colon: methods and first results of 5 patients; 3D-MRT des Kolons: Methodik und erste Ergebnisse  

Energy Technology Data Exchange (ETDEWEB)

Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal pathologies could be interactively diagnosed by MPR. On MIP images some pathologies were missed. VC ...

1997-09-01

30

Primary malignant lymphoma of the brain; Primaere maligne Lymphome des Gehirns  

Energy Technology Data Exchange (ETDEWEB)

Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its multiplanar capability, lack of bone-induced artifacts, and high-contrast ...

1997-01-01

31

Vessel wall MRI of the thoracic aorta: correlation to histology and transesophageal ultrasound. Preliminary results  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To visualise the vessel wall of the descending thoracic aorta using magnetic resonance imaging. To evaluate the diagnostic potential of tailored T{sub 1}-weighted sequences with contrast enhancement to assess systemic atherosclerotic disease. Methods: This study was performed on a clinical 1.5 Tesla scanner using a gradient strength of 30 mT/m and the phased array spine coil. A cadaver was examined to optimise a magnetic resonance imaging (MRI) protocol to evaluate atherosclerotic aortic wall disease. The acquired MR images were compared to gross specimens and histology. Subsequently seven patients who had undergone transesophageal ultrasound (TEU) with detailed assessment of the descending thoracic aorta were examined with MRI. The optimised protocol included untriggered and fat suppressed T{sub 2}-weighted turbo spin echo sequences and ECG-triggered and fat suppressed T{sub 1}-weighted spin echo sequences before and after iv administration of Gd-DTPA. ...

2002-05-01

32

MR imaging guidance and monitoring of focal thermotherapies. A review; Steuerung und Monitoring von fokalen Thermotherapien mit der Magnetresonanztomographie. Ein Ueberblick  

Energy Technology Data Exchange (ETDEWEB)

Minimally invasive thermotherapies for focal tissue destruction on the basis of laser-, microwave-, focused ultrasound-, or cryogeninduced changes of tissue temperature represent an alternative to surgical tissue ablation, particularly in the treatment of tumors. The thermotherapy modalities listed necessitate indirect guidance and monitoring, since they often do not lend themselves to immediate visual control. In the brain, in head and neck tumors, in the liver, and in the prostate, MRI reliably and accurately delineates both the positions of interstitial thermotherapy applicators and - in contrast-enhanced, T1-weighted images - the perfusion defects in tissue necrosis induced by thermotherapy. The transfer of results of in-vitro and in-vivo model studies to assess interstitial temperature and lesion development during thermotherapy to the actual treatment of patients, however, is still in an initial phase. Further development of both rapid MRI sequences and MRI ...

1998-03-01

33

Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system; Hochaufloesendes Ganzkoerpertumorstaging unter Verwendung paralleler Bildgebung im Vergleich zur PET-CT. Erste Erfahrungen auf einem 32-Kanal-MRT-System  

Energy Technology Data Exchange (ETDEWEB)

To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table ...

2004-09-01

34

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T_2-weighted utrafast turbo-spin-echo sequence (UTSE)  

International Nuclear Information System (INIS)

Purpose: To evaluate a T_2-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T_2-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR_e_f_f/T_E/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was better for the ...

1999-05-01

35

The new WHO classification of brain tumors. Radiological aspects of 4 new tumor entities; Die revidierte WHO-Klassifikation der Hirntumoren. Radiologische Aspekte unter besonderer Beruecksichtigung von vier neuen Tumorentitaeten  

Energy Technology Data Exchange (ETDEWEB)

Characterisation of the classification of brain tumours authorised by the WHO. Method of appraisal: This classification was revised and published in its second version. In the revision, some tumours were regrouped histogenetically and some tumour variants were added. Radiologically relevant changes of the classification include the differentiation of four new tumour entities that are easily distinguished by MR imaging. These four tumours belong to the group of childhood tumours or tumours occurring in early adulthood and are characterized by a good prognosis after extirpation. Results of appraisal: Central neurocytomas are small-cyst ventricular tumours associated with the foramen of Monroi and show moderate contrast enhancement. Infantile desmoplastic gangliogliomas/astrocytomas commonly consist of a solid tumour portion related to the leptomeninges with pronounced contrast enhancement and a typically very large cyst. Pleomorphic ...

1997-06-01

36

MRT versus CT in the diagnosis of pneumonia. Evaluation of a T{sub 2}-weighted utrafast turbo-spin-echo sequence (UTSE); MRT versus CT in der Diagnostik von Pneumonien. Evaluation einer T{sub 2}-gewichteten ultraschnellen Turbo-Spin-Echo-Sequenz (UTSE)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate a T{sub 2}-weighted URSE sequence for the assessment of pulmonary infiltrations in comparison to CT. Methods: 28 MRT scans of 22 patients with confirmed pneumonia were recorded on a 1.5 Tesla apparatus with an expiratory and diastolic triggered, T{sub 2}-weighted ultrafast-spin-echo sequence in axial slice mode with the following parameters: TR{sub eff}/T{sub E}/Turbofactor 2000-4000/90 ms/21-23; slice thickness/separation 6/0.6 mm; FOV 360 mm; 24 slices. 24 spiral CTs (sice thickness/table advance: 1-2 mm/10 mm) were available for comparison. The separate evaluation of MRTs and CTs was performed by three radiologists in a consensus procedure with regard to pulmonary lesions (e.g., infiltration, round foci, net patterns) and image quality of the MRTs (4-step scale). Results: In 71% of the cases the CTs and MRTs agreed with the diagnosis and representation of the lesions, in 25% MRT was superior. MRT was ...

1999-05-01

37

MRI of liposarcomas. Observations on 28 liposarcomas; Magnetresonanztomographie der Liposarkome. Beobachtungen an 28 Liposarkomen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Liposarcoma is the most common soft tissue sarcoma in adults. The purpose of the study was to correlate MR imaging features with the four ICD subclasses. Methods: 28 patients with liposarcoma were examined preoperatively on a 1.0 T MRI system, using spin echo sequences, gradient echo imaging and STIR sequences. In all patients, classification of the liposarcomas was made by histologic diagnosis (ICD-10-M-classification). Results: Well differentiated liposarcomas (9 patients) showed a number of MRI features consistent with lipoma (well defined mass high signal intensity (SI) on T{sub 1} images, low signal on T{sub 2} images, no or only little signal increase of tumour tissue after contrast material application, no necrosis). Not well differentiated liposarcomas (myxoid 14 patients, pleomorphic three patients, round cell two patients) revealed the largest part of the mass to be of low SI on T{sub 1}-weighted images. Only scattered fatty islands and septa (9 ...

1996-08-01

38

Radiological diagnosis of lesions of intervertebral discs  

International Nuclear Information System (INIS)

During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.)

2003-03-01

39

The diagnosis of inflammatory muscular and vascular conditions using MRT with STIR sequences  

International Nuclear Information System (INIS)

The role of MRT in the prebiopsy diagnosis of muscular and vascular inflammatory conditions was evaluated prospectively and an optimal method of examination was investigated. 92 patients with a suspected diagnosis of myositis (60 cases) or vasculitis (32 cases) were examined, in each case two extremities were studied using transverse T_1 and T_2 weighted SE sequences and double echo STIR sequences on a 0.5 Tesla (56 patients) or 1.5 Tesla magnet (36 patients; T5/S15 Gyroscan, Philips). The site of the biopsy depended on the MRT findings. In 41 patients the suspected diagnosis was confirmed histologically, in two patients an infective myositis was diagnosed on clinical grounds despite negative histology. MRT demonstrated muscle oedema in 86% of patients. There were negative findings after immuno-suppressive therapy (two patients), in focal myositis (3 out of 4 patients) and in one of 7 patients with untreated vasculitis. ...

40

Incidence of lesions as described by MRI in focal epilepsy of frontal and temporal onset; Inzidenz kernspintomographisch erfassbarer Laesionen bei der Abklaerung fokaler Epilepsien frontalen und temporalen Ursprunges  

Energy Technology Data Exchange (ETDEWEB)

Aim: Today, MRI is an integral part of the presurgical evaluation of patients suffering from partial epilepsy. These patients frequently show focal morphological abnormalities with potential epileptogenic character and surgical resection of these lesions is associated with superior postsurgical outcome as to seizure frequency. Apart from easily detectable defects, such as post-traumatic lesions or cerebral infarction, as wide variety of mainly small abnormalities can be detected using MRI. Methods: In this study, 484 patients suffering from partial epilepsy of temporal or frontal onset were evaluated for the incidence of different lesions in this population. Results: All lesions found were included without evaluating their potential epileptogenicity, which remains to be proven using other procedures (EEG, SPECT, PET, etc.). Involvement of the hippocampal formation was a major finding in temporal lobe epilepsy, which could be detected as sclerosis (T2w-images), atrophy (T2w-TSE or ...

1997-09-01

41

Comparison of contrast-enhanced flash and turbo-flash with conventional spin-echo sequences as a basis for morphologocal MR imaging for planning high-precision radiotherapy of intracranial brain tumors. Comparison of FLASH-, turbo-FLASH and SE-sequences; Morphologische MR-Bildgebung mit T1-gewichteten Sequenzen zur radiotherapeutischen Zielvolumendefinition von intrakraniellen Tumoren. Vergleich von FLASH-, Turbo-FLASH- und SE-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Introduction: The goal of this study was to compare contrast-enhanced T1-weighted Flash and Turbo-Flash sequences with conventional spin-echo sequences as a basis for planning high-precision radiotherapy. Methods: A total of 25 consecutive patients with different intracranial tumors and a disrupted blood-brain barrier were studied. T1-weighted Flash, Turbo-Flash and conventional spin-echo images were evaluated after controlled 30-s infusion of 0.1 mmol/kg body weight of Gd-DTPA. The evaluation of the three sequences included the measurement of the signal- and contrast-to-noise ratios, the visual inspection of the tumors and artifacts, and the measurement of tumor size. Results: The signal- and contrast-to-noise ratios were significantly (P<0.05-0.01) lower for Flash and Turbo-Flash than for conventional spin-echo sequences. However, visual inspection of the contrast-enhancing tumors revealed in 23 ...

1997-03-01

42

Magnetic resonance imaging of the urogenital diaphragma in comparison with conventional histomorphological findings (the controversy about the deep transverse muscle of perineum); Kernspintomographische Untersuchungen des Diaphragma urogenitale im Vergleich mit korrespondierenden histomorphologischen Befunden (der Streit um den Misculus transversus perinei profundus)  

Energy Technology Data Exchange (ETDEWEB)

The transversus perinei profundus muscle is a well known structure in found anatomical textbook. Fibres of this muscle are believed to form the so-called external urethral sphincter (musculus sphincter urethrae). Recently histomorphologic investigations have shown that there is no muscular connection between the musculus sphincter urethrae (external sphincter) and the muscle system of the pelvic floor. Furthermore, the external sphincter was found to be divided into parts: The transversely striated part (musculus sphincter urethrae transversostriatus) and the smooth part (musculus sphincter urethrae glaber). Similar to histomorphologic investigations, contrast-enhanced MR imaging has shown the musculus sphincter urethrae to be surrounded by fatty and connective tissue only. Neither in MRI nor in anatomical slices can any connection between the urethral sphincter and the muscle system of the pelvic floor be found. Thus, on the basis of the results presented in this ...

1997-01-01

43

Magnetic resonance imaging in joint diseases  

International Nuclear Information System (INIS)

Magnetic resonance imaging has proven an invaluable method in the diagnosis of joint diseases associated with osteonecrotic, inflammatory, traumatic and degenerative processes. At the clinical level, it has an important role in decisions about the method of treatment and evaluations of the therapeutic success. When the merits of MRT are balanced against those of conventional radiography including tomography and CT, which both ensure better spatial resolution in the visualisation of cortical and spongy bone structures, it becomes quite evident that MRT must not be regarded as an alternative method of imaging but as one that can be used additionally to obtain the most information for the diagnosis of arthropathy. The question as to whether new pulse sequences (snap shots) or invasive techniques like intra-articular injection of paramagnetic substances (MR arthrography) are likely to become routine procedures in the detection of joint diseases ...

44

Early diagnosis of skeletal disorders in childhood and adolescence by MRI; Fruehdiagnose orthopaedischer Erkrankungen des Kindes- und Jugendalters mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The early diagnosis of such disorders is of major importance because, in most cases, severe consequences can only be averted by early treatment. The value of magnetic resonance imaging (MRI) in many orthopaedic and traumatological conditions is generally accepted. The value of MRI in this particular field is illustrated by typical case reports on common clinical problems [Deutsch] Der Fruehdiagnose von Erkrankungen des Kindes- und Jugendalters kommt grosse Bedeutung zu, da oftmals nur durch eine daraus resultierende Fruehbehandlung schwerwiegende Folgen vermieden werden koennen. Die Kernspintomographie (Magnetresonanztomographie=MRT) ist in zahlreichen orthopaedischen-traumatologischen Fragestellungen bereits etabliert. An ausgewaehlten Fallbeispielen haeufiger klinischer Problemstellungen soll in der vorliegenden Arbeit der Stellenwert der MRT dargestellt werden. (orig.)

1998-09-18

45

MR imaging of the lateral collateral ligaments after ankle sprain; Aussenbandrupturen des Sprunggelenkes - Darstellung mit der MRT vor und nach funktioneller Therapie  

Energy Technology Data Exchange (ETDEWEB)

35 patients with ankle sprain were examined by MRI and stress radiographs. 13 were operated afterwards, 22 patients underwent a functional conservative therapy and were examined by MRI and stress radiographs and second time after three months. MRI reports were correct in 12 of 13 operated cases. After conservative therapy we did not find any disrupted ankle ligament. MRI showed intact ligaments thickened by scar. (orig./MG) [Deutsch] 35 Patienten mit klinischem Verdacht auf Aussenbandruptur wurden mit der MRT untersucht. 13 Patienten wurden operiert, 22 konzervativ therapiert. Letztere wurden nach drei Monaten erneut mit MRT und gehaltenen Aufnahmen untersucht. Die MRT-Befunde stimmten in 12 von 13 Faellen mit den operativ erhobenen Befunden ueberein. Nach dreimonatiger konzervativer Therapie waren alle 22 Sprunggelenke stabil. Die rupturierten Baender stellten sich verdickt und durchgaengig dar. (orig./MG)

1995-09-01

46

Diagnostic possibilities following implantation of carbon-fibre-reinforced plastic (CFRP) total hip arthroplasty  

International Nuclear Information System (INIS)

Introduction: There are many problems in the radiological diagnosis of aseptic loosening in total hip arthroplasty. Computed tomography (CT) and magnetic resonance tomography (MRT) are not usable for metallic implants (stainless steel, cobalt alloy, titanium alloy). Material and Methods: From April 1993 to December 1993 15 CFRP non-cemented hip prostheses have been implanted. In a prospective clinical study plane radiographs, CT and MRT have been analysed. Results: Three stems were revised (1 femoral fracture, 1 severe thigh pain, 1 aseptic loosening). CFRP are not visible in plane radiographs. There was a complete (two-third of the cases) or nearly complete (one-third of the cases) small sclerotic interface between the prosthesis and the bone, these were apparent in CT and MRT in stable implant cases and did not have any clinical correlations. Discussion: The small sclerotic interface is quite different in comparison to so ...

47

Diffusion and perfusion MR imaging in stroke; MR-Diffusion und -Perfusion beim Schlaganfall  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) in stroke makes it possible to visualize the initial infarct in cases of acute cerebral ischemia. Perfusion MRI serves to determine which tissues are additionally at risk of infarction due to persistent hypoperfusion. MRI also allows those examiners with limited experience to reliably confirm an infarct. The most important differential diagnosis of cerebral ischemia, intracerebral hemorrhage, can likewise be recognized with certainty using MRI. Although diffusion and perfusion MRI only demonstrate the pathophysiology of cerebral ischemia approximately, the method is suited for identifying those patients who would profit from reperfusion therapy. Whether MRI is also appropriate as an aid to reaching a prognosis on the risk of secondary hemorrhage has not yet been resolved. (orig.) [German] Die Schlaganfall-MRT ermoeglicht es, bei akuter zerebraler Ischaemie den bereits initial entstandenen Infarkt darzustellen. Mittels ...

2005-05-01

48

MRI survival guide; MRT Basiskurs  

Energy Technology Data Exchange (ETDEWEB)

The book is a German translation of an American textbook with the original title ''MRI Survival Guide'' and is intended to serve as an introductory guide for beginners or a reference book for quick information. Readers will find information on the fundamentals of the technology and methodology of MRI as well as all details of relevance to practice in a precise and easy-to-grasp arrangement, covering all anatomic areas of interest, illustrations and descriptions of characteristic signs of pathologic processes, high-quality and unusually large-sized diagnostic pictures, a modern didactic concept for quick orientiation, including surveys, tables, and reproductions for visualisation of contents. (orig./CB) [German] Praktisch jeder Mediziner wird im Laufe seiner Berufstaetigkeit mit der MRT konfrontiert - unabhaengig davon ob in der Radiologie, Orthopaedie, Gynaekologie, Chirurgie, Neurologie oder sonstigen Fachrichtung. Das Buch ist ...

1999-07-01

49

SPIO-enhanced MR angiography for the detection of venous thrombosis in an animal model; SPIO-unterstuetzte MR-Angiographie zur Detektion venoeser Thromben im Tiermodell  

Energy Technology Data Exchange (ETDEWEB)

Purpose: An animal model is used to investigate whether MR angiography combined with super-paramagnetic particles of iron oxide (SPIO) is suitable for detecting thromboses. Methods: 42 rats in groups of 7 each were examined on days 1, 3, 5, 7, 9 and 11, respectively, after mechanical/chemical thrombus induction in a 1.5 Tesla magnet with a FISP sequence (TR/TE/FA 50 ms/6 ms/40 ). Imaging was performed before and up to 90 minutes after intravenous injection of 30 {mu}mol FE/kg BW of the experimental SPIO (hydrodynamic diameter, 34{+-}17 nm LLS; R1 and R2 relaxivity at 0.47 T, 31 and 57 L/(mmol*s)). MIP reconstructions of MR angiographies were submitted to consensus assessment by two examiners using histology as the gold standard. Results: The image quality of MIP reconstructions was rated as good in 38 of 42 cases. With regard to thrombotic vessel occlusion, MR angiography coincided with histology in 17 of 42 cases and differed in 25, lumen narrowing being overestimated by MRI in 4 ...

1999-03-01

50

Imaging techniques for the injured ankle joint and tarsal bones  

International Nuclear Information System (INIS)

In the case of injuries of the ankle joint, an imaging technique is expected to reveal the state of the bones, ligaments, and articular cartilage. Irrespective of novel imaging techniques, a plain radiography will be made in order to obtain a first picture of the injury. Examples are given, showing that further orientation along the Lauge-Hansen classification scheme of this type of injury helps to completely ascertain the damage to the Articulatio talocruralis. Further examinations applying specific methods such as arthrography will detect possible, isolated syndesmosis ruptures; lesions of the ligaments can also be directly detected by CT or MRT. The articular cartilage and its lesions can be visualized by a combination of CT and arthrography, but are better shown by the completely non-invasive MRT. This latter method also gives insight into pathological processes with the bone. It allows to detect necrotic bone regions and their ...

51

Radiological diagnosis of lesions of intervertebral discs; Radiologische Diagnostik von Bandscheibenlaesionen  

Energy Technology Data Exchange (ETDEWEB)

During their life, intervertebral discs undergo degenerative changes which need not necessarily become lesions. Conventional X-rays do not provide information on the condition of the intervertebral discs, so MRT or CT are recommended as primary techniques as they are non-invasive. Invasive methods like myelography and especially discography should not be used unless a case is highly problematic. In infants with pains in the back, MRT should be carried out as early as possible as there is nearly always an organic cause. (orig.) [German] Die Bandscheibe ist im Laufe des Lebens degenerativen Veraenderungen unterworfen, die klinisch zu Beschwerden fuehren koennen, aber nicht fuehren muessen. Konventionlle Roentgenaufnahmen lassen zwar die Hoehenminderung des Bandscheibenfachs und begleitende knoecherne Veraenderungen erkennen, nicht aber den Zustand der Bandscheibe selbst. Die Beurteilung der Bandscheibe und des Knochens gelingt mit der CT, die ...

2003-03-01

52

New procedures. Comprehensive staging of lung cancer by MRI; Neue Verfahren. Umfassendes Staging des Lungenkarzinoms mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Lung cancer staging according to the TNM system is based on morphological assessment of the primary cancer, lymph nodes and metastases. All aspects of this important oncological classification are measurable with MRI. Pulmonary nodules can be detected at the clinically relevant size of 4-5 mm in diameter. The extent of mediastinal, hilar and supraclavicular lymph node affection can be assessed at the same time. The predominant metastatic spread to the adrenal glands and spine can be detected in coronal orientation during dedicated MRI of the lungs. Search focused whole body MRI completes the staging. Various additional MR imaging techniques provide further functional and clinically relevant information during a single examination. In the oncological context the most important techniques are imaging of perfusion and tumor motion. Functional MRI of the lungs complements the pure staging and improves surgical approaches and radiotherapy planning. (orig.) [German] Das Staging des ...

2010-08-15

53

MRI in postoperative assessment of univentricular heart disease: correlation with echocardiography and angiography; MRT in der postoperativen Diagnostik bei funktionell univentrikulaerem Herz: Korrelation zu Echokardiographie und Kardangiographie  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the postoperativ evaluation of a singular ventricle compared to echocardiography and cardiac catheterization. Materials and methods: Thirty-one patients (range: 6 months to 30 years) with a functional single ventricle following palliative corrective operations. Five patients had a Blalock-Taussig-Shunt, 8 patients a Glenn-Anastomosis and 18 a cavopulmonary shunt (6 with classic Fontan-Circulation, 12 with modified cavopulmonary anastomosis). The results in terms of postoperative morphologic changes were compared to percutaneous echocardiography (31/31) and cardiac catheterization (6/31). Results: Echocardiography, which was performed on all patients, could not visualize the entire length of the tunnel, the Glenn-Anastomosis or the central pulmonary arteries in 70% of the patients due to an inadequate acoustic window. MRI was able to show the entire tunnel in 11/12 patients and the central pulmonary arteries in 30/31 patients. The exact anatomy ...

2002-12-01

54

Assessment of the value of various tomography modalities for diagnostic evaluation of the female genital system; Stellenwert der Schnittbildverfahren bei der Abklaerung von Erkrankungen des weiblichen Genitaltrakts  

Energy Technology Data Exchange (ETDEWEB)

The comprehensive survey explains the indications and the specific value of the modern tomographic modalities with respect to the various diagnostic issues. Numerous reproductions of CT, MRI, US scans illustrate the aspects discussed. (orig./CB) [German] Bildgebende Verfahren kommen bei der Abklaerung von Erkrankungen des weiblichen Urogenitaltrakts ergaenzend zu der klinischen Untersuchung zur Anwendung. Kongenitale Uterusanomalien werden primaer mit der HSG oder der Laparoskopie diagnostiziert. Zusaetzlich koennen der transvaginale US und in unklaren Faellen die MRT eingesetzt werden. Die Diagnose entzuendlicher Erkrankungen des weiblichen Genitaltrakts erfolgt in der Regel klinisch. Schnittbildverfahren werden bei therapieresistenten, komplizierten Faellen angewendet. Initial werden benigne Neoplasien des Uterus mit dem transvaginalen US abgeklaert. Eine Verdickung des Endometriums ist dabei ein unspezifischer Befund und kann auf eine Hyperplasie, Polypen oder ...

2001-09-01

55

MRI in preoperative evaluation of chronic paranasal sinusitis - a comparison with CT; MRT in der praeoperativen Diagnostik der chronischen Sinusitis im Vergleich mit der CT  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the value of MRI in the preoperative evaluation of chronic paranasal sinusitis and to compare the results with CT and intraoperative findings. Method/Materials: 42 patients with clinical signs of chronic paranasal sinusitis underwent MRI after CT evaluation on one day, with subsequent functional endoscopic sinus surgery on the next day. Coronary CT was obtained with 5-mm slices and table-feed in the prone position, while MRI was performed in the supine position with coronary T{sub 2}-TSE+pd and coronary and transverse HASTE, each with 5-mm slice thickness. Aquisition time in MRI was less than 8 minutes. Two radiologists reviewed the CT and MRI scans for signs of sinusitis and detection of anatomical landmarks. The results were correlated with the intraoperative findings. Results: MRI offered no artifacts of dental work and showed more often high quality pictures than CT. CT and MRI demonstrated a good correlation in the detection of mucosal pathologies ...

2001-04-01

56

Blood flow quantification with MRI using the phase mapping method. Moeglichkeiten und Grenzen der Blutflussquantifizierung peripherer arterieller Gefaesse mit der MRT unter Anwendung des Phase-Mapping-Verfahrens  

Energy Technology Data Exchange (ETDEWEB)

MRT is able to demonstrate arteries while MR angiography can quantify blood flow by a non-invasive method. In the present paper blood flow measurements were carried out in four selected cases on the basis of phase mapping. In 3 patients with lesions in the pelvis or thigh, angiography was performed in order to localise the stenosis or occlusion and this was followed by qantitative blood flow measurements. The results showed that angiography may not always provide all necessary information concerning a haemodynamically significant stenosis. The method may also be used for quantifying blood flow in the renal arteries and that it has significant advantages over the colour Doppler method. (orig.).

1992-08-01

57

Sodium bicarbonate-based hydration prevents contrast-induced nephropathy: a meta-analysis  

UK PubMed Central (United Kingdom)

BackgroundContrast-induced nephropathy is the leading cause of in-hospital acute renal failure. This side effect of contrast agents leads to increased morbidity, mortality, and health...Full Text Available

58

MRI of the pancreas: Radiological-pathological correlation; MRT des Pankreas: Radiologisch-pathologische Korrelation  

Energy Technology Data Exchange (ETDEWEB)

The typical MRI features of the most common pancreatic diseases, such as pancreatitis and adenocarcinoma of the pancreas, have been established. However, even in these common pancreatic disorders, MRI correlation with the underlying pathology is limited for clinical reasons. We emphasize MR-pathological correlation of inflammatory and neoplastic pancreatic changes, including pancreatitis, adenocarcinoma, acinar cell carcinoma, rare cystic and solid pancreatic neoplasms, and islet cell tumors. By highlighting the correlation of key pathological features with MR findings, a better understanding of the MR appearance of pancreatic pathology can be provided. In addition, MRI may prove a powerful tool in detection and characterization of pancreatic tumors. (orig.) [Deutsch] Das MR-tomographische Erscheinungsbild von Pankreatitiden und Adenokarzinomen des Pankreas, als den haeufigsten Pankreaserkrankungen, ist zwar ausreichend bekannt; allerdings ist selbst bei diesen Pankreaserkrankungen die ...

1996-05-01

59

Injured lateral ankle ligaments: technique and assessment of MRI; Verletzungen des Aussenbandapparates am oberen Sprunggelenk: Untersuchungstechnik und Nachweis mittels MRT  

Energy Technology Data Exchange (ETDEWEB)

56 patients with the clinical diagnosis of sprained ankles were investigated. Evaluation of the anterior (AFTL) and posterior fibulotalar ligament (PFTL) was performed with the foot in dorsiflexion (20 ) and of the fibulo calcanear ligament (FCL) in plantarflexion (45 ). Axial T{sub 1}w-SE and T{sub 2}w-TSE images were obtained. Full-length visualisation of ligmaments in one slice and the extent of injury were evaluated. 12 ankle injuries were confirmed by operation. With MRI full-length visualisation of lateral ankle ligaments was possible in 86%. A partial/complete rupture of the AFTL was noticed in 33/64% and of the FCI in 29/39%, and of the PFTL in 27/5%. Sensitivity/specificity of MRI when compared to surgery was 100/100% for injuries of the AFTL, 64/100% for the FCL, and 33/78% for the PFTL. (orig./MG) [Deutsch] 56 Patienten wurden mit der klinischen Diagnose einer frischen Supinationsverletzung des oberen Sprunggelenkes untersucht. Das Lig. talofibulare anterius (TFA) und ...

1996-03-01

60

Diagnosis of occipital condyle fractures; Diagnostik von Frakturen der Okzipitalkondylen  

Energy Technology Data Exchange (ETDEWEB)

Following the conventional X-ray diagnosis of the skull and upper cervical spine, CT proved to be the primary diagnostic method after a skull and brain injury: For all 4 cases we succeeded in detecting the occipital condyle fracture and in determing its size and location by reconstructions (coronal, sagittal, 3-D). In the case of complex occompanying injuries like soft tissue hematomas (cerebral, in the spinal cord, and the soft tissue of the neck) or for the detection of brain stem contusion, MRT had significant advantages. MRT can offer a higher image quality in soft tissue, especially in the spinal cord and the brain. (orig.) [Deutsch] Im Anschluss an die konventionelle Roentgendiagnostik des Schaedels und der Halswirbelsaeule, erwies sich die Computertomographie als primaer einzusetzendes diagnostisches Verfahren, nach erlittenem Schaedel-Hirn-Trauma. In allen Faellen gelang der exakte Frakturnachweis an den Okzipitalkondylen, die ...

1995-01-01

61

Cystic lesions of the seminal vesicles. Demonstration by MRI. Zystische Raumforderungen der Samenblasen. Darstellung mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Between October 1990 and March 1991, 8 patients with cystic lesions in the region of the posterior bladder wall, the seminal vesicles and the prostate were examined by MRI. In all cases there was accurate characterisation of the lesion and of its anatomy. In 3 patients with abnormalities in the retrovesical space there was very good agreement with the operative findings. 4 patients were treated conservatively. In these patients there was good agreement with the findings on cystoscopy, CT and sonography. (orig.).

1992-07-01

62

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil; Lymphknotenstaging beim Zervixkarzinom: Ergebnisse der hochaufloesenden Magnetresonanztomographie (MRT) mit einer Phased-Array-Koerperspule  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T{sub 2}-weighted turbo-spin-echo (TSE) and T{sub 1}-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm{sup 2}. Lymph nodes with a diameter of {>=}8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes ({>=} 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: High-resolution MR imaging ...

1997-03-01

63

Functional MRI of the pharynx in obstructive sleep apnea (OSA) with rapid 2-D flash sequences; Funktionelle MRT des Pharynx bei obstruktiver Schlafapnoe (OSA) mit schnellen 2D-FLASH-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Functional imaging of the pharynx used to be the domain of cineradiography, CT and ultrafast CT. The development of modern MRI techniques led to new access to functional disorders of the pharynx. The aim of this study was to implement a new MRI technique to examine oropharyngeal obstructive mechanisms in patients with obstructive sleep apnea (OSA). Sixteen patients suffering from OSA and 6 healthy volunteers were examined on a 1.5 T whole-body imager (`Vision`, Siemens, Erlangen Medical Engineering, Germany) using a circular polarized head coil. Imaging was performed with 2D flash sequences in midsagittal and axial planes. Patients and volunteers were asked to breathe normally through the nose and to simulate snoring and the Mueller maneuver during magnetic resonance imaging (MRI). Prior to MRI, all patients underwent an ear, nose and throat (ENT) examination, functional fiberoptic nasopharyngoscopy and polysomnography. A temporal resolution of 6 images/s and an in-plane resolution of ...

1996-03-01

64

Determination of cartilage thickness in the ankle joint. MRT (1,5 T) comparative anatomical study; Bestimmung der Knorpeldicke am oberen Sprunggelenk. Eine MRT(1,5 T)-anatomische Vergleichsstudie  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to evaluate the accuracy of MRI in the measurement of cartilage thickness of the ankle joint in comparison to pathologic and histologic specimens. Patients and methods: The ankle joints of four fresh cadaver feet were imaged on a 1.5 T MR-unit in the coronal plane. Standard T{sub 1}-weighted spin echo (SE) and a T{sub 1}-weighted 3D-GE (FLASH-3D) sequence with fat saturation were applied. Following MR imaging, the talus was explanted and cut parallel to the MR images for macroscopic evaluation and histologic specimens were prepared. MRI measurements of the cartilage thickness of the talus were carried out in two ways: Without and with consideration of a transition zone of intermediate signal intensity between hyperintense cartilage and hypointense cortical bone. The data were compared with the anatomic specimens as the gold standard expressing the difference as a percentage value. On histologic specimens thickness of deep calcified cartilage layer was ...

1997-04-01

65

Role of nuclear medicine and magnetic resonance imaging in cardiac diagnostics; Rolle der nuklearmedizinischen Verfahren und der Magnetresonanztomographie in der kardialen Diagnostik  

Energy Technology Data Exchange (ETDEWEB)

Nuclear medicine and magnetic resonance imaging (MRI) are widely used in cardiac diagnostics. Both techniques have been carefully evaluated and are equivalent for the assessment of regional and global wall motion as well as the evaluation of ejection fraction and cardiac volumes, though MRI is herein currently seen as gold standard. For evaluation of myocardial perfusion, extensive data exist for nuclear imaging, that, next to high diagnostic accuracy for evaluation of coronary artery disease, show incremental prognostic information and allow for independent risk stratification. Because of rapid technical advance, myocardial perfusion imaging has also become feasible with cardiac MRI. Results of recent studies are promising, but the data are few compared to perfusion scintigraphy. For viability assessment in patients with ischemic cardiomyopathy, positron emission tomography (PET) with FDG is currently seen as gold standard. However, single photon emission computed tomography (SPECT) ...

2003-12-01

66

Staging of osteochondritis dissecans of the knee and ankle with MRI. Comparison with conventional radiography and arthroscopy; Die Stadienbestimmung der Osteochondrosis dissecans am Knie- und Sprunggelenk mit der MRT. Vergleich mit konventioneller Radiologie und Arthroskopie  

Energy Technology Data Exchange (ETDEWEB)

A prospective study was performed on 50 patients suffering from osteochondritis dissecans of the knee and ankle to define criteria for stability and fixation of osteochondral lesions. Morphological parameters in MRI (size, fragmentation, cartilage, interface) and conventional radiology (separation, fragmentation) were registered and compared with arthroscopical staging. MRI staging based on different types of interfaces was demonstrated on T{sub 1}- and T{sub 2}-weighted images. MRI could correctly predict a Grade 1 lesion in 50%, a Grade 2 lesion in 90%, a Grade 3 lesion on 0%, and a Grade 4 lesion in 79%. Stable lesions were differentiated from unstable lesions in 90%. Radiographic findings corresponded with arthroscopic staging in only 56% of the cases because fibrotic connection may guarantee stability in case of bony separation. (orig./MG) [Deutsch] In einer prospektiven Studie an 50 Patienten mit einer Osteochondrosis dissecans (OD) des Knie- und Sprunggelenkes sollten ...

1995-07-01

70

Dialysis and contrast media  

Energy Technology Data Exchange (ETDEWEB)

In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of ...

2002-12-01

71

Contrast factors in nuclear magnetic resonance imaging  

International Nuclear Information System (INIS)

In Nuclear Magnetic Resonance (NMR) imaging, contrast is dependent on the emission of radiofrequency waves by atomic nuclei, balanced by several parameters. The high information content of NMR images is due to the multiplicity of its parameters. However, this advantage introduces a difficulty in the interpretation of the contrast. There are three contrast parameters for each tissue: hydrogen nuclei density; relaxation time T1; relaxation time T2. Contrast may be enhanced towards any of these parameters by increasing the emission of radiowaves by atomic nuclei using particular pulse sequences.

1985-01-01

72

Soft tissue manifestations of early rheumatic disease. Imaging with MRI; Fruehmanifestationen rheumatischer Gelenkerkrankungen an den Weichgewebestrukturen der Hand. Nachweis mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to evaluate typical magnetic resonance imaging (MRI) findings in early rheumatic diseases manifesting at the soft tissues of the hand using a retrospective analysis. A total of 186 MRI examinations of patients with clinical suspicion of a rheumatic disease were evaluated in a consensus reading by two experienced radiologists. All imaging patterns were assessed with respect to their type and localization. Under blinded and non-blinded conditions diagnoses were correlated with final clinical diagnosis. The most frequent diagnoses were rheumatoid arthritis (RA, 45.7%) and psoriatic arthritis (PsA, 15.6%). The mean correlation between clinical and MRI diagnosis (r) was 0.75 in blinded and 0.853 in non-blinded reading (p <0.001). The following extra-articular imaging patterns were found: synovitis (59.1%), tendovaginitis (91.4%), dactylitis (14.5%), and bone marrow edema (18.3%). Only dactylitis was specific for a particular rheumatic disease (PsA; r=0.934; ...

2006-08-15

73

Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution in the z-axis. Especially for follow-up examinations in ...

2006-04-15

74

Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI; Untersuchung der atemabhaengigen Bewegungen pulmonaler Raumforderungen mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool to select patients for motion-adapted radiotherapy. In ...

2009-08-15

75

Inflammatory spine disease as a cause of back pain; Entzuendliche Wirbelsaeulenerkrankungen als Ursache fuer Rueckenschmerzen  

Energy Technology Data Exchange (ETDEWEB)

The aim of this review is to evaluate the role of inflammatory spine disease in patients with chronic back pain. The contribution of imaging modalities for the diagnostic evaluation of back pain is discussed. A systematic literature search based on the classification of seronegative spondyloarthropathies and rheumatoid arthritis was performed. The results of this search and the experiences in a large collective of rheumatological patients are analyzed. The prevalence of rheumatoid arthritis (1-2%) is comparable to that of spondyloarthropathies (1.9%). The etiology of these entities is not fully elucidated. Magnetic resonance imaging is increasingly used for early detection and surveillance of therapy with TNF-{alpha} antagonists. Bone marrow edema, which is only detectable with MRI, represents an early sign of inflammation. Therapy with TNF-{alpha} antagonists is based on clinical and laboratory criteria, and signs of inflammation in MRI. MRI is useful for assessment of the ...

2006-06-15

76

Assessment of flow quantification in coronary bypass grafts and coronary arteries with velocity-encoded cine MR imaging; Flussquantifizierung in Koronar- und Bypassgefaessen mit der MR-Phasenkontrasttechnik  

Energy Technology Data Exchange (ETDEWEB)

Materials and methods: 12 patients with 22 coronary bypass grafts underwent intraoperative flow quantification using the transit time ultrasound method. These values were compared to postoperative MR phase shift measurements. Flow measurements were performed preoperatively in 28 coronary arteries of 20 patients. For flow measurement, we used a velocity-encoded k-space segmented gradient echo sequence with a temporal resolution of 110 or 125 ms, respectively. 6-8 pase shift images could be acquired during one cardiac cycle. Results: There was a significant correlation between intraoperative and flow measurements using velocity-encoded MR imaging (r=0.76, p<0.0001, t-test). Flow volumes determined by MR imaging were systematically larger than those determined by the transit time ultrasound method. Mean flow in coronary arteries was reduced in severely stenosed vessels (>70%) compared to normal vessels. Intra- and interobserver variability were 10.5 and 15% (coronary bypass ...

2000-02-01

77

Whole-body tumor staging: MRI or FDG-PET/CT?; Ganzkoerpertumorstaging: MRT oder FDG-PET/CT  

Energy Technology Data Exchange (ETDEWEB)

Technical innovations such as the availability of movable patient platforms and the introduction of 32-channel systems have made whole-body MRI for tumor staging feasible. In addition, the development of dual-modality PET/CT systems offers the opportunity to perform anatometabolic tumor staging with whole-body coverage in a single session. Based on an increase in patient survival when applying a stage-adapted therapy in different malignant diseases the relevant question relates to the accuracies of whole-body MRI and whole-body PET/CT for TNM staging. This review article addresses whole-body tumor staging with MRI and FDG-PET/CT with special emphasis on diagnostic accuracies for staging different malignant diseases. (orig.) [German] Technische Neuerungen, wie die Verfuegbarkeit beweglicher Tischaufsaetze oder die Einfuehrung von 32-Kanal-Systemen, haben die Ganzkoerperbildgebung mit der MRT ermoeglicht. Die Entwicklung kombinierter PET/CT-Systeme bereitet den Weg ...

2004-09-01

78

The value of high-resolution MR-imaging for the staging of malignant lesions of tongue, pharynx and larynx; Klinische Wertigkeit der hochaufloesenden Magnetresonanztomographie beim Staging von Tumoren der Mundhoehle, des Pharynx und des Larynx  

Energy Technology Data Exchange (ETDEWEB)

In a prospective study 102 patients with malignant tumors of the tongue, oropharynx, hypopharynx, and larynx were staged by means of MRI. Special attention was directed at those tumour extensions that could influence the treatment strategy. The MR findings were correlated with the results of palpation, endoscopy, ultrasound, computerised tomography and histopathological findings. MRI showed a good delineation of pT{sub 2} to pT{sub 4} tumours. However, visualisation of small tumours in the soft palate, the tonsils, the pyriform sinuses and vocal cords was difficult. In conclusion our results suggest that in addition to endoscopy MRI is a valuable tool for the examination of tumours of tongue, oropharynx, hypopharynx and larynx. (orig.) [Deutsch] In einer prospektiven Studie wurden 102 Patienten mit malignen Tumoren der Mundhoehle, des Oro- und Hypopharynx sowie des Larynx mit der Mgnetresonanztomographie (MRT) untersucht, wobei besonders Wert auf die Bestimmung ...

1994-02-01

79

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

80

On the internal perceptual structure of distinctive features: The [voice] contrast  

UK PubMed Central (United Kingdom)

Several fixed classification experiments test the hypothesis that F1, f0, and closure voicing covary between intervocalic stops contrasting...Full Text Available

2008-01-01

81

High Contrast Near-infrared Polarized Reflectance Images of Demineralization on Tooth Buccal and Occlusal Surfaces at ?=1310-nm  

UK PubMed Central (United Kingdom)

Background and Objectives:Sound enamel manifests peak transparency in the near-IR (NIR) at 1310-nm, therefore the near-IR is ideally suited for high contrast imaging...Full Text Available

2009-03-01

82

Dynamic NMR effects in breast cancer dynamic-contrast-enhanced MRI  

UK PubMed Central (United Kingdom)

The passage of a vascular-injected paramagnetic contrast reagent (CR) bolus through a region-of-interest affects tissue 1H2O relaxation and thus MR image intensity. For longitudinal...Full Text Available

2008-11-18

83

Analysis of the Sulfate-Reducing Bacterial and Methanogenic Archaeal Populations in Contrasting Antarctic Sediments  

UK PubMed Central (United Kingdom)

The distribution and activity of communities of sulfate-reducing bacteria (SRB) and methanogenic archaea in two contrasting Antarctic sediments were investigated. Methanogenesis dominated in freshwater...Full Text Available

2003-06-01

84

Genetic Applications in Avian Conservation  

Science.gov (United States)

... structure along an elevational gradient in Hawaiian honeycreepers reveals contrasting evolutionary responses to avian malaria. BMC Evolutionary Biology 8: ... ...

85

Differential diagnosis by CT units with contrast enhancement  

Energy Technology Data Exchange (ETDEWEB)

Variation of CT units, in organs, before and after using contrast enhancing medium was reviewed and personal experience was presented. In the normal brain CT units was little changed by contrast enhancement (CE), whereas remarkable change was observed at lesions. No difference of CT units was observed between the normal liver and hepatomas. The normal kidney had higher CE effect than hypernephromas suggesting an increase of the sensitivity. CE was not found in cysts or necrosis. The changes of CT units in the cases of cerebral diseases are tabled with various contrast medium and scanners.

1981-04-01

87

Addition of methyl cellulose enema to double-contrast barium imaging of sigmoid diverticulosis  

Energy Technology Data Exchange (ETDEWEB)

Double-contrast barium enema has a reduced sensitivity in patients with severe sigmoid diverticulosis. Therefore a carboxy methyl cellulose enema was employed after the conventional double-contrast examination in 15 patients with sigmoid diverticulosis. A significant increase in lumen diameter and a superior removal of barium residue from the diverticulas facilitated the interpretation of the sigmoid loops. Conclusion: The addition of methyl cellulose enema to double-contrast barium imaging improves diagnostic imaging in diverticulosis by expanding the lumen and emptying the diverticulas. (orig.).

1997-01-01

88

AM: An Artificial Intelligence Approach to Discovery in ...  

Science.gov (United States)

... For example, contrast solving the Missionaries and Cannibals problem with the more ill-defined reasoning which led to inventing it. ...

1976-07-01

89

A bright field scanning transmission electron microscope (STEM ...  

Science.gov (United States)

A bright field scanning transmission electron microscope (STEM) micrograph showing a Wassonite grain in dark contrast. ...

90

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase ...

2008-12-15

91

MRI of congenital heart disease in childhood; MR-Tomographie kongenitaler Herzvitien im Kindesalter  

Energy Technology Data Exchange (ETDEWEB)

MRI provides a non-invasive diagnostic tool complementing echocardiography on one hand, and showing advantages over echocardiography, on the other hand, especially after corrective procedures. The multiple different MRI sequences need to be adapted to examinations of children and patients with congenital heart disease (CHD), and can be used to detect morphologic changes, blood-flow in the heart and thoracic vessels and diastolic or systolic function of myocardium. Several factors determine the success of the examination of a complex congenital heart disease or a postoperative situs. Pediatric radiologists and radiologists experienced in congenital heart diseases have to work in close cooperation. Echocardiography should be performed before MRI. The results of prior examinations and the clinical history of the patients, including possible palliative or reconstructive operations, must be available before MRI to guide the planning of the examination. With a systematic segmental approach ...

2004-02-01

92

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase imaging with respect ...

2009-09-01

93

What is the best contrast injection protocol for 64-row multi-detector cardiac computed tomography?  

International Nuclear Information System (INIS)

Objective: To determine the optimal contrast injection protocol for 64-MDCT coronary angiography. Materials and methods: One hundred and fifty consecutive patients scheduled to undergo retrospectively electrocardiographically gated 64-MDCT. Each 30 patients were assigned to use a different contrast protocol: group 1: uniphasic protocol (contrast injection without saline flush); group 2: biphasic protocol (contrast injection with saline flush); group 3A, 3B and 3C: triphasic protocol (contrast media + different saline diluted contrast media + saline flush). Image quality scores and artifacts were compared and evaluated on both transaxial and three-dimensional coronary artery images among each contrast protocol. Results: Among the triphasic protocol groups, group 3A (30%:70% contrast media-saline mixture was used in second ...

2010-08-01

94

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei and their return to aligned rest is used as input to a ...

1999-10-01

95

MRI in the diagnosis of non-compacted ventricular Myocardium (NCVM) compared to echocardiography; MR-Tomographie in der morphologischen Darstellung der isolierten non-compaction des linksventrikulaeren Myokards (NCVM)  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To report the detection of con-compacted ventricular myocardium (NVCM) with MRI compared to echocardiography in 8 patients. Material and methods: Non-compaction of the ventricular myocardium is a congenital disorder characterized by an altered structure of the myocardial wall resulting from an intrauterine arrest in endomyocardial embryogenesis. The morphological findings consist of a prominent meshwork of multiple myocardial trabeculations and deep intertrabecular recesses, communicating with the left ventricular cavity. 8 consecutive patients (mean age 7.3 years) with clinical and echocardiographic signs of NCVM were examined by MRI (1.5 T, Vision, Siemens) in short axis and 2- and 4-chamber views, using T{sub 1}-weighted TSE and Cine-GRE in 6 patients and true FISP sequences in 2 patients. MRI and echocardiography were evaluated for visibility, signs of NCVM and involvement of myocardial wall segments. Thickness was measured for non-compacted and compacted myocardium and ...

2003-09-01

96

Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik  

Energy Technology Data Exchange (ETDEWEB)

The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography and especially 16- and 64-detector row ...

2004-09-01

97

Phylogenetic constraints on digesta separation: Variation in fluid throughput in the digestive tract in mammalian herbivores  

British Library Electronic Table of Contents (United Kingdom)

The relevance of the mean retention time (MRT) of particles through the gastrointestinal tract (GIT) is well understood and MRTparticleGIT is an important parameter in digestion models. Solute markers have been used to estimate MRTsoluteGIT (or 'fluid passage') in animals, but the relevance of this measure is less evident and is usually sought in its relation to MRTparticleGIT. The ratio between the two measures indicates the degree of 'digesta washing', with little washing occurring at ratios of 1, aborad washing at ratios >1 (where the solute marker travels faster than the particle marker), and orad (retrograde) washing at ratios <1 (where the solute marker travels slower than the particle marker). We analysed digesta washing in a dataset of 98 mammalian species including man of differen...

2011-01-01

98

Magnetic resonance imaging of chronic aortic dissection  

International Nuclear Information System (INIS)

17 patients with chronic aortic dissection were examined by MRI. In 12 patients, comparison between gradient echo sequences and SE sequences was possible. Gradient echo sequences, unlike SE sequences, permitted evaluation of flow in the true and false lumen, reliable differentiation between thrombus and flowing blood and clear delination of the intimal flap. An additional comparison between transoesophageal ultrasound and MRT in 15 patients showed significant advantages in favour of MRI. In three patients MRI was able to detect more proximal origins of the dissection. Moreover, MRI allowed evaluation of the major aortic branches and their relation to the dissection; this was not possible with ultrasound. MRI plays an important role in the follow-up of chronic aortic dissections. (orig.).

99

MRT for operation planning in anal atresias  

International Nuclear Information System (INIS)

We evaluated in this study the value of preoperative examinations of anal atresia with an optimised MRI strategie. 13 patients with anorectal anomalies, most of them younger than one year, underwent an MRI examination of the pelvis. 10 of these patients were operated afterwards. Compared with the situs shown by the operation the results of the MRI examination were very exact in all cases in respect of the level of atresia and the development of the striateed muscle complex. Fistulas could be completely described in most cases. MRI demonstrated additional lesions in some patients which were of great importance for planning the further treatment of the patients. As a consequence MRI can give valid information on anal atresia for planning the operative treatment. (orig.).

100

Electrical biasing and voltage contrast imaging in a focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

We present two new techniques that enhance conventional focused ion beam (FIB) system capabilities for integrated circuit (IC) analysis: in situ electrical biasing and voltage contrast imaging. We have used in situ electrical biasing to enable a number of advanced failure analysis applications including (1) real time evaluation of device electrical behavior during milling and deposition, (2) verification of IC functional modifications without removal from the FIB system, and (3) ultraprecision control for cross sectioning of deep submicron structures, such as programmed amorphous silicon antifuses. We have also developed FIB system voltage contrast imaging that can be used for a variety of failure analysis applications. The use of passive voltage contrast imaging for defect localization and for navigation on planarized devices will be illustrated. In addition, we describe new, biased voltage contrast ...

1995-09-01

102

Value of MRCP using oral Gd-DTPA as negative contrast materials in diagnosis of atypical juxtapapillary duodenal diverticulum  

British Library Electronic Table of Contents (United Kingdom)

Objective To investigate value of magnetic resonance cholangiopancreatography (MRCP) using oral diluted gadolinium (Gd)-diethylenetriamine penta-acetic acid (DTPA) as negative contrast materials in diagnosis of juxtapapillary duodenal diverticulum with atypical imaging features. Methods Nineteen patients with juxtapapillary duodenal diverticula of which imaging findings were atypical underwent MRCP using oral diluted Gd-DTPA as negative contrast materials after conventional MRCP without any oral contrast materials. Results Twenty diverticula were revealed in the 19 patients. At conventional MRCP, the diverticula appeared as rounded lesion with high signal intensity. After oral administration of diluted Gd-DTPA, they disappeared at MRCP. These entities were diagnosed as duodenal diverticula...

2009-01-01

103

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

104

Symbiotic regulation of plant growth, development and reproduction  

UK PubMed Central (United Kingdom)

The growth and development of rice (Oryzae sativa) seedlings was shown to be regulated epigenetically by a fungal endophyte. In contrast to un-inoculated (nonsymbiotic) plants, endophyte...Full Text Available

2009-03-01

105

Physiological and Biochemical Variations during the Molt Cycle in Juvenile Litopenaeus vannamei under Laboratory ...  

Science.gov (United States)

... 05). In contrast with the information available for Penaeus monodon Fabricius, 1798 (Ferraris et al., 1987) and L. vannamei ( ... ...

106

Interaction of legionella pneumophila and helicobacter pylori with bacterial species isolated from drinking water biofilms  

UK PubMed Central (United Kingdom)

BackgroundIt is well established that Legionella pneumophila is a waterborne pathogen; by contrast, the mode of Helicobacter pylori transmission...Full Text Available

107

Double plasma mirror for ultrahigh temporal contrast ultra-intense laser pulses  

International Nuclear Information System (INIS)

We present and characterize a very efficient optical device that employs the plasma mirror technique to increase the contrast of high-power laser systems. Contrast improvements higher than 104 with 50% transmission are shown to be routinely achieved on a typical 10 TW laser system when the pulse is reflected on two consecutive plasma mirrors. Used at the end of the laser system, this double plasma mirror preserves the spatial profile of the initial beam, is unaffected by shot-to-shot fluctuations, and is suitable for most high peak power laser systems. We use the generation of high-order harmonics as an effective test for the contrast improvement produced by the double plasma mirrors. (authors)

108

Digital subtraction angiography with scanning lazer stimulated luminescence  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was ...

1985-01-01

110

Contrast Sensitivity and Optical Quality of the Eye after Instillation of Timolol Maleate Gel-Forming Solution and Brinzolamide Ophthalmic Suspension  

British Library Electronic Table of Contents (United Kingdom)

Purpose To investigate the influence of timolol maleate 0.5% gel-forming solution and brinzolamide 1% ophthalmic suspension on contrast sensitivity, ocular higher-order aberration (HOA), and corneal surface light scattering. Design Prospective, comparative study. Participants Forty normal volunteers were enrolled in this study. Methods We evaluated contrast sensitivity, ocular HOA, and corneal light scattering before and 2, 5, 10, and 15 minutes after instillation of antiglaucoma eyedrops. Contrast sensitivity function was assessed with the CSV-1000RN chart (Vector Vision Co., Greenville, OH). Higher-order aberration was measured for a 4-mm pupil using the Hartmann-Shack aberrometer (KR-9000PW; Topcon, Tokyo, Japan). Corneal surface light scattering was quantitatively evaluated by using th...

2010-01-01

111

Chronic kidney disease in children: the global perspective  

UK PubMed Central (United Kingdom)

In contrast to the increasing availability of information pertaining to the care of children with chronic kidney disease (CKD) from large-scale observational and interventional studies, epidemiological...Full Text Available

2007-12-01

112

Cancer as a metabolic disease  

UK PubMed Central (United Kingdom)

Emerging evidence indicates that impaired cellular energy metabolism is the defining characteristic of nearly all cancers regardless of cellular or tissue origin. In contrast to normal cells, which...Full Text Available

113

10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography  

Energy Technology Data Exchange (ETDEWEB)

CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% ...

1990-10-15

114

10% low density corn-oil emulsion oral contrast agent for abdominal computed tomography  

International Nuclear Information System (INIS)

CT of the gastrointestinal tract is commonly performed after administration of a high-density diluted iodinated oral contrast material. However, because if inadequate mixing of the contrast material with the gastrointestinal contents, pseudotumor and poor mucosal visualization are frequently shown on abdominal CT. To overcome these problem, 10% corn oil emulsion (COE) is tested as an alternative oral contrast agent in 40 patients. We analyse patients tolerance, gastric mucosal visualization and discrimination of pancreas from the duodenal C-loop to 10% COE in 40 patients compared with those obtained from 35 patients, who was received high-density diluted iodinated oral contrast agent (gastrografin). The results are as follows : 1. Patients' tolerance to 10% COE is similar to that to conventional oral contrast agent. 2. Image of the gastric mucosa from patients receiving 10% COE is ...

1990-10-01

115

Osteonecrosis of the hip joint in adults; Die Osteonekrose des Hueftgelenks im Erwachsenenalter  

Energy Technology Data Exchange (ETDEWEB)

Osteonecrosis (ON) of the hip joint remains an unsolved therapeutical problem. Diagnosis of ON of the hip has been improved by the technical progress of imaging modalities and better understanding pathomorphology. Over a long period only plain radiographs have been available. Scintigraphy and computed tomography contributed to differential diagnosis and early detection of bone necrosis. Diagnosis in an early reversible stage is of importance. Understanding of pathophysiology, early diagnosis and therapeutical approach has been significantly improved by MR imaging. Using the ARCO system all imaging modalities and their diagnostic viability are described in the five ARCO stages. At the end a diagnostic algorithm will be proposed. (orig.) [German] Die Osteonekrose des Hueftgelenks (ON) stellt noch immer ein nicht geloestes therapeutisches Problem dar. Die diagnostischen Moeglichkeiten bei der ON wurden in den letzten Jahren durch technische Fortschritte bei den bildgebenden Verfahren und ...

2002-06-01

116

MRT of carotid stents: influence of stent properties and sequence parameters on visualization of the carotid artery lumen; MRT bei Karotisstens: Einfluss von Stenteigenschaften und Geraeteparametern auf die Darstellbarkeit des Karotislumens  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To evaluate MR artifacts of carotid artery stents and to optimize stent properties and sequence parameters. Material and Methods: Four carotid artery stents - Wallstent (mediloy), Precise (nitinol), ACCULINK (nitinol) and a stent prototype (nitinol) - were investigated in a flow model of the cervical vessels. The model was made of silicon tubing and a flow pump that produces realistic flow curves of the carotid artery. To investigate the effects of magnetic susceptibility and radiofrequency induced shielding artifacts, turbo spin echo and gradient echo sequences as well as CE-MRAs were measured. To improve the visualization of the stent lumen in a CE-MRA, flip angle as well as geometry and covering of the stent prototype were altered. Results: Susceptibility artifacts in stents of the carotid artery only influence the lumen visualization at the proximal and distal end of the braided mediloy stent. A change of stent coverings has no significant influence on radiofrequency ...

2005-03-01

117

High-End CT for clinical and scientific applications; High-End-CT im klinischen und wissenschaftlichen Einsatz  

Energy Technology Data Exchange (ETDEWEB)

The enhancements described of high-performance CT systems of latest design have again confirmed the importance of CT systems for acute and selective diagnostic imaging. Higher availability, shorter exposure times, and better applicability and handling for examination of poly-traumata patients or patients of intensive care departments are some of the advantages achieved with CT systems which demonstrate CT system efficiency in addition to MRI, which for specific examinations will remain the modality of first choice for diagnostic evaluation. The Tomoscan Av-E presented here was able to answer all relevant diagnostic questions appearing in routine diagnostics and scientific work. For patients, examinations using the spiral CT technique also offers significant advantages. (orig./CB) [Deutsch] Durch die dargestellten Verbesserungen bei Hochleistungs-CT-Systemen neuester Bauart wurde die Bedeutung der CT fuer die akute und selektive Diagnostik erneut bestaetigt. Bessere Verfuegbarkeit, ...

1997-12-01

118

Extension of adrenal tumors into the vena cava: results of magnetic resonance angiography; Kavazapfen bei Nebennierentumoren: Kernspintomographische Befunde  

Energy Technology Data Exchange (ETDEWEB)

In rare cases, large adrenal masses with a suspicion of malignancy exhibit tumor extension into the adrenal vein and inferior vena cava. When planning surgery, the relationship of the extension to the inferior vena cava is of decisive improtance. We describe in two cases on the detection of a tumor thrombus in the inferior vena cava arising from a malignant adrenal mass by means of MR angiography (TOF, coronary 2D GRE images [FLASH], 3 slices acquired during 15 second apnea). The angiograms correlated well with the results of DSA venacavography and with the intraoperative findings. Thus, MRA has been demonstrated to be suitable for the certain proof of a venous tumor thrombus not only in cases of renal cell carcinomas but also in cases of malignant adrenal masses. The method should be applied whenever there is evidence of a venous involvement in the adrenal MR images. (orig.) [Deutsch] Grosse malignomverdaechtige Nebennierentumoren zeigen in seltenen Faellen eine Tumorausdehnung in die ...

1995-11-01

119

MRI-based N-staging in esophageal cancer; N-Staging des Oesophaguskarzinoms mittels MRT unter Verwendung von artefaktreduzierenden LOTA-Sequenzen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: For planning the therapeutic strategies and estimating the prognosis in esophageal cancer, N-staging is very important. To date, MRI still is of minor importance as imaging modality of the mediastinum despite promising developments in the past, like ECG-gating or 'averaging' sequences, e.g. LOTA (Long-term averaging), which facilitate mediastinal and thoracic MR-imaging. In a prospective approach, the value of MRI based N-staging was examined with respect to LOTA-sequences. Material and Methods: Within from weeks prior to esophagectomy, standardized MRI of the esophagus was performed in 15 patients (10 squamous-cell-carcinomas and 5 adenocarcinomas) using a 1.5 T whole body scanner. Imaging quality was classified based on depiction of aortic wall or tracheal wall layers. Criteria for malignant infiltration were a diameter of more than 15 mm or a round appearance of a lymph node together with GD-DTPA enhancement. All data were blinded and separately read by ...

2002-10-01

120

Ultrasmall superparamagnetic iron oxides (USPIOs): a future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)?  

UK PubMed Central (United Kingdom)

Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available

2009-03-01

121

Multiple imaging radiography at LNLS  

Energy Technology Data Exchange (ETDEWEB)

An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.

2008-01-11

122

Magnetic resonance imaging in acute intractional tuberculosis  

International Nuclear Information System (INIS)

We reported three cases of acute intracranial tuberculosis including miliary tuberculosis, basal meningitis, tuberculomas and neuritis of cranial nerves. All patients had native and contrast enhanced CT and MRI scans. MRI revealed more granulomas and a better imaging contrast in the detection of basal meningitis. Neuritis was diagnosed only with the MRI. MRI scans should be prefered as the imaging procedure in clinically presumed intracranial tuberculosis. (orig.).

123

Computer tomographic ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.

1982-04-01

124

Wavelength-Dependent Differential Interference Contrast Microscopy: Selectively Imaging Nanoparticle Probes in Live Cells  

Energy Technology Data Exchange (ETDEWEB)

Gold and silver nanoparticles display extraordinarily large apparent refractive indices near their plasmon resonance (PR) wavelengths. These nanoparticles show good contrast in a narrow spectral band but are poorly resolved at other wavelengths in differential interference contrast (DIC) microscopy. The wavelength dependence of DIC contrast of gold/silver nanoparticles is interpreted in terms of Mie's theory and DIC working principles. We further exploit this wavelength dependence by modifying a DIC microscope to enable simultaneous imaging at two wavelengths. We demonstrate that gold/silver nanoparticles immobilized on the same glass slides through hybridization can be differentiated and imaged separately. High-contrast, video-rate images of living cells can be recorded both with and without illuminating the gold nanoparticle probes, providing definitive probe identification. Dual-wavelength ...

2009-11-15

125

CT diagnosis of intrahepatic cholangiocarcinoma  

International Nuclear Information System (INIS)

Purpose: To evaluate contrast-enhanced CT scan in the diagnosis of intrahepatic cholangiocarcinoma by correlating the CT appearance with pathologic specimens. Materials and methods: Twenty-eight patients with pathologically proven intrahepatic cholangiocarcinoma were examined. Unenhanced abdominal CT study were performed in 28 patients; conventional contrast-enhanced CT in 27 patients. Enhanced CT scan including fast injection, fast scan and delayed scan at the largest section of the lesion was done in 7 patients. Contiguous 10 mm CT scans of the surgical specimens were also obtained in 8 patients. The preoperative and specimen CT scans in these 8 patients were compared with the corresponding pathological sections. A total of 103 areas of the pathological sections was compared with the CT appearances. Results: All lesions contained areas of delayed contrast enhancement and/or no enhancement on CT examinations. The areas of ...

126

Observation and control of hepatic specimens with MRI and MRS; Beobachtung und Kontrolle von Fixiervorgaengen in Leberpraeparaten mittels MRT und MRS  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The purpose of this study was to observe the process of fixation in liver specimens non-invasively by means of magnetic resonance. The fixation process of several formaldehyde-containing solutions was monitored with MRI and MRS at two different temperatures. Materials and Methods: Liver specimens were conserved in aqueous fixative solutions containing formaldehyde concentrations of 0.7, 1.8, 4 and 7.2% and at different temperatures of 5 C and 20 C. MRI was performed with T1-, T2- and PD-weighted TSE sequences, a 2D FLASH-sequence with and without magnetization transfer, and a FISP 3D-sequence on a clinical 1.5 Tesla MR whole-body unit, and MRS with {sup 1}H-spectroscopic methods (STEAM-sequence) on a 3 Tesla MR whole-body unit. Results: The diffusion of formaldehyde into the tissue was best identified on PD- and T1-weighted images as a band under the liver surface with increasing thickness, penetrating especially fast during the first three days. Spectroscopic measurements ...

2004-04-01

127

MR-based volumetric analysis of small tumor volumes: accuracy of phantom examinations of simulated eye tumors; Evaluierung der MR-Volumetrie kleiner Volumina am Beispiel von Augentumoren mittels Phantomuntersuchungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The determination of tumor volume in ocular tumors is very important for the planning and success of radiation therapy. This study uses an animal model to evaluate the accuracy of MR-based volumetry of ocular tumors. Materials and methods: In a total of 25 porcine eyes obtained from the slaughterhouse, ocular tumors were produced by injecting a mixture of hand creme and Gd-DTPA under ophthalmoscopic guidance. The injected volume varied between 0.05 ml and 2.7 ml. The eyes were examined with a 1.5 Tesla scanner and a 4 cm circular surface coil especially developed for ocular MRI. After data transfer to a separate workstation, volumetric analysis was carried out by three independent radiologists using semiautomated software. The determined volume was compared with the injected volume. Results: Of the 25 prepared porcine eyes, 23 were suitable for volumetric analysis. The injection of the mixture of hand creme and GD-DTPA produced two different types of tumors. ...

2003-07-01

128

Differential diagnosis of rheumatic diseases; Differenzialdiagnose rheumatischer Erkrankungen  

Energy Technology Data Exchange (ETDEWEB)

Which imaging modalities are appropriate for the Differential diagnosis of Rheumatic diseases. MRI has far most the highest sensitivity and is unequaled in its brilliant presentation of Anatomy and Pathology. But it is sometimes forgotten, that this is at least in part the result of carefully selected sequences, dedicated to the expected result. In a method totally independent of any result, this should not be the case. In contrary this method should be highly standardised and regardless what will be the findings. This is true for Plain X-ray. It will be shown, that already the outer silhouette of the soft parts with different features of swelling, and differences in density and even more - defects or appositions of the bony silhouette in the majority of cases at least will allow to classify the patient for a group of diseases and in many cases will lead to a definite diagnosis. Differential diagnoses like Rheumatoid Arthritis versus Psoriatic Arthritis or simply but not always simple ...

2006-05-15

129

Phase- and size-adjusted CT cut-off for differentiating neoplastic lesions from normal colon in contrast-enhanced CT colonography  

Energy Technology Data Exchange (ETDEWEB)

A computed tomography (CT) cut-off for differentiating neoplastic lesions (polyps/carcinoma) from normal colon in contrast-enhanced CT colonography (CTC) relating to the contrast phase and lesion size is determined. CT values of 64 colonic lesions (27 polyps <10 mm, 13 polyps {>=}10 mm, 24 carcinomas) were determined by region-of-interest (ROI) measurements in 38 patients who underwent contrast-enhanced CTC. In addition, the height (H) of the colonic lesions was measured in CT. CT values were also measured in the aorta (A), superior mesenteric vein (V) and colonic wall. The contrast phase was defined by xA + (1 - x)V using x as a weighting factor for describing the different contrast phases ranging from the pure arterial phase (x=1) over the intermediate phases (x=0.9-0.1) to the pure venous phase (x=0). The CT values of the lesions were correlated with their height ...

2004-12-01

130

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a variable-sized operator-selectable iris diaphragm would permit this dose-reduction approach to ...

1983-11-01

131

Magnetization transfer contrast effect on multislice fast spin echo  

Energy Technology Data Exchange (ETDEWEB)

Magnetization transfer contrast (MTC) on fast spin echo (FSE) images was evaluated in normal brain tissue as well as in brain tumors to better understand contrast of FSE images. On multislice FSE images, attenuation of the signal intensity of brain tissue due to MTC is observed. The rate of MTC (MTR) is obtained by comparing with additional single slice images. The effect of signal attenuation is greater on images with smaller interslice gap, larger number of slices, and longer echo train length. MTR of brain tumors is less than that of normal brain tissue. Among them, meningiomas have relatively high MTR, and cavernous malformation has relatively low MTR. Determination of MTC can be easily specified by obtaining multislice and single slice FSE images, and it may help differentiate brain tumors. (author).

1994-03-01

132

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography  

British Library Electronic Table of Contents (United Kingdom)

Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...

2011-01-01

133

Diagnostic quality in hysterosalpingography  

International Nuclear Information System (INIS)

Purpose: To compare the diagnostic quality and adverse events of the water-soluble, non-ionic, iso-osmolar, dimeric contrast media iodixanol and iotrolan in hysterosalpingography (HSG). Material and Methods: One hundred and twenty patients participated in a double-blind randomized parallel-group phase-III study. Questionnaires and patient interviews were used. Diagnostic quality was assessed using a visual analogue scale and the quality in specific regions was rated using a categorical scale. Results: Overall diagnostic quality was equal for the two groups. There was no statistically significant difference between the two groups in diagnostic quality in the specific regions of interest. No differences between the contrast media were found with regard to adverse events. Conclusion: Both contrast media provided images of high diagnostic quality in HSG. (orig.)

1998-11-01

134

Contrast material extravasation following upper abdominal trauma. Detection with helical Computerized Tomography  

International Nuclear Information System (INIS)

Active contrast material extravasation can be recognized with conventional CT scanners, though it has been considered a rare finding. Helical CT seems to increase the detection rate and especially to boost the radiologist's confidence in this diagnosis. Though active bleeding is defined in severely-injured subjects requiring urgent intervention and may be associated with findings of hypovolaemic shock, it should not be considered itself as a negative prognostic factor. Contrast extravasation is due to ongoing hemorrhage and its detection is critical for urged treatment. Accurate anatomical location permits to choose surgical management or transcatheter embolization and thus decreases time consumption for precis e bleeding site identification.

1999-03-01

135

Colour contrast in ballistic gelatine  

British Library Electronic Table of Contents (United Kingdom)

Gelatine is a reliable tissue simulant in wound ballistic experiments. The projectile penetrating the gelatine transfers energy and causes radial cracks according to the temporary cavity. Thus the crack length is a function of the energy spent in the medium. In practice the fissures are poorly contrasted for which reason an enhancement of contrast was searched. A series of six shoots with expanding bullets (9mmx19 Action-5, 9mmx19 Quick Defense 1, 5.56mmx45 Styx Action) was realized on 10% gelatine blocks at 4^oC temperature. Three blocks were marked with acryl paint on the front, three blocks were shot native. The blocks were cut in slices of 1cm thickness and optically scanned. The evaluation was performed according to Fackler's wound profile, the total crack length method and the polygo...

2010-01-01

136

Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil  

International Nuclear Information System (INIS)

Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: High-resolution MR imaging with a c.p. ...

137

Handbook on diagnostic radiology. Muscels and skeleton 2; Handbuch diagnostische Radiologie. Muskuloskelettales System 2  

Energy Technology Data Exchange (ETDEWEB)

The second volume contains a comprehensive presentation of inflammatory bone diseases, including seldom primary chronic osteomyelitis and morbus Paget. Substantial chapters on bone tumors and tumor-like lesions of bone joints are covering the state-of-the-art of diagnostic techniques of these seldom but important diseases. Besides the importance of projection radiography the contribution of MRI within differential diagnosis und staging of these diseases is emphasized. [German] Der zweite Band des Muskuloskelettalen Systems befasst sich mit der umfassenden Darstellung zur Diagnostik entzuendlicher Knochenerkrankungen und beinhaltet neben den klassischen infektioesen auch die seltenen, primaer chronischen Osteomyelitiden und den Morbus Paget. Umfangreiche Kapitel ueber die Knochentumoren und tumoraehnlichen Laesionen der Gelenke stellen in modernster Weise den aktuellen Stand des Wissens und der Diagnostik dieser seltenen, aber aus differenzialdiagnostischer Sicht sehr wichtigen ...

2005-07-01

138

Evaluation of left ventricular volumes in patients with congenital heart disease and abnormal left ventricular geometry. Comparison of MRI and transthoraic 3-dimensional echocardiography; Vergleich der transthorakalen 3D-Echokardiographie mit der MRT zur Bestimmung linksventrikulaerer Volumina bei Patienten mit pathologischer Ventrikelgeometrie aufgrund angeborener Herzfehler  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To assess the new method of 3-dimensional echocardiography in comparison to the 'gold standard' MRI as to its ability to calculate left ventricular volumes in patients with congenital heart disease. Materials and methods: Eighteen patients between the ages of 3.9 to 37.3 years (mean: 12.8{+-}9.7) with a geometrically abnormal left ventricle were examined using a 1.5 T scanner with a fast gradient-echo sequence (TR=14 ms, TE=2.6-2.9 ms, FOV=300-400 mm, flip angle=20 , matrix=128:256, slice thickness=5 mm, retrospective gating) in multislice-multiphase technique. Transthoracic 3D-echocardiography was performed with a 3.5 MHz transducer and a Tomtec {sup trademark} (Munich, Germany) system for 3D reconstruction. Results: Volume calculation was possible in all patients with 3D-echocardiography, but the muscle mass calculation only succeeded in 11 to 18 patients (61%) due to inadequate visualization of the entire myocardium. Comparing MRI and 3D-echocardiography, ...

2003-07-01

139

Benign and malign pulmonary tumors in childhood; Benigne und maligne Lungentumoren im Kindesalter  

Energy Technology Data Exchange (ETDEWEB)

Pulmonary tumors in children are rare. Nevertheless, there are besides malign primary neoplasms and metastases also some benign tumors that the radiologist should know. The identification of some tumors is difficult, since some of them may mimic pulmonary inflammation. The first diagnostic tool is chest radiography. After that, a CT with contrastmedium should be performed, if possible a multislice-CT (MSCT). Identification of mediastinal structures is best with MRI. (orig.) [German] Tumoren der Lunge sind im Kindesalter selten. Trotzdem finden sich neben den malignen primaeren und sekundaeren Raumforderungen auch im Kindesalter immer wieder benigne Tumoren, die der Radiologe kennen sollte. Eine eindeutige Identifizierung kann schwierig sein, da z. B. entzuendliche Infiltrate vorgetaeuscht werden koennen. Die primaere Untersuchungsmethode ist das konventionelle Thoraxroentgen. Die weitere Diagnostik muss mit der Computertomographie, nach Moeglichkeit mit einem ...

2003-12-01

140

Atlas and toolbook of MR mammography; Lehratlas der MR-Mammographie  

Energy Technology Data Exchange (ETDEWEB)

This richly illustrated toolbook and atlas contains information on all aspects of nmr diagnostic imaging of benign or malignant neoplasms of female and male mammary glands. It offers pinpointed guidance and insight for vocational training and continuing training of radiology assistants, students and medical radiologists. (orig./AJ) [German] Die MRT als hochaufloesendes und schaedigungsfreies Diagnostikum gewinnt gerade in der emotional stark besetzten Mammadiagnostik zunehmend an Bedeutung. Dennoch beherrschen nur wenige Zentren im deutschsprachigen Raum diese Technik, die - eine hohe Reproduzierbarkeit bei fehlender Belastung fuer die Patientin bietet, - invasive Karzinome bereits ab einer Groesse von 5 mm mit hoher Zuverlaessigkeit ausschliessen kann und - gerade bei widerspruechlichen Befunden zwischen klinischer Untersuchung, Roentgenmammographie und perkutaner Biopsie eine wesentliche Entscheidungshilfe bieten kann. Aus einem der fuehrenden Zentren in der ...

2000-07-01

141

Preoperative MR-guided localization of suspicious breast lesions; MR-gesteuerte praeoperative Drahtmarkierung unklarer Mammalaesionen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Small suspicious breast lesions that are only visible at MR imaging were preoperatively marked with a hook wire under MR-guidance to allow the removal of the lesion with tissue-sparing surgery. Method: In all patients the suspicious lesions were marked preoperatively under MR guidance with a hook wire using a commercially available stereotactic device. Interventions were performed with MR guidance on a 1.0 T and on a 1.5 T system. Results: In 19 patients 22 lesions were localized. One lesion was missed and removed in a second procedure. The mean duration for localization was 66{+-}20 min (range 38-119 min). In two patients two lesions were localized. The mean deviation of the wire tip to the lesion was 2,0{+-}2,6 mm. In this series, 6 of 22 lesions were malignant. The mean diameter of the lesion was 7.6{+-}2.6 mm (range 3-14 mm). Conclusion: Suspicious breast lesions detectable only in MR imaging can be accurately localized with a hook wire preoperatively under MR control to ...

2000-09-01

142

In vitro investigation of biological and technical prosthetic heart valves in MRI: evaluation of possible deflection and heating of the implants; In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung moeglicher Anziehung und Erhitzung der Implantate  

Energy Technology Data Exchange (ETDEWEB)

Purpose: In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 C, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. Results: None of the investigated prosthetic heart valves was deflected. The maximal observed temperature rise was 0.5 C. During MR investigation of the prostheses, artifacts caused by metallic parts were less evident using a spin-echo sequence than a gradient-echo sequence. Conclusions: Patients with the tested present-day prosthetic heart valves can be safely imaged by ...

2000-02-01

143

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this ...

2002-03-01

144

The zebrafish heart regenerates after cryoinjury-induced myocardial infarction  

UK PubMed Central (United Kingdom)

BackgroundIn humans, myocardial infarction is characterized by irreversible loss of heart tissue, which becomes replaced with a fibrous scar. By contrast, teleost fish and urodele...Full Text Available

145

The Oxidation Behavior of CoCrAlY, CoCrAl and Yttrium ...  

Science.gov (United States)

... ADD137758. Title : The Oxidation Behavior of CoCrAlY, CoCrAl and Yttrium-Implanted CoCrAl Alloys Compared and Contrasted,. ...

1987-11-01

146

Synthesis and characterization of PVP-coated large core iron oxide nanoparticles as an MRI contrast agent  

UK PubMed Central (United Kingdom)

The purpose of this study was to synthesize biocompatible polyvinylpyrrolidone (PVP)-coated iron oxide (PVP-IO) nanoparticles and to evaluate their efficacy as a magnetic resonance imaging (MRI)...Full Text Available

2008-04-01

147

Squamous Cell Carcinoma in South-Eastern Equatorial Rain Forest in Calabar, Nigeria  

UK PubMed Central (United Kingdom)

Background: In North America and Europe, 80% of invasive skin cancers are basal cell carcinoma while 20% are squamous cell carcinoma (SCC). In contrast, African studies reveal a preponderance...Full Text Available

148

STRUCTURE OF THE MACULA UTRICULI WITH SPECIAL REFERENCE TO DIRECTIONAL INTERPLAY OF SENSORY RESPONSES AS REVEALED BY MORPHOLOGICAL POLARIZATION  

UK PubMed Central (United Kingdom)

The anatomy of the labyrinth and the structure of the macula utriculi of the teleost fish (burbot) Lota vulgaris was studied by dissection, phase contrast, and electron microscopy....Full Text Available

1964-08-01

149

Pulmonary toxicity and carcinogenicity of trichloroethylene: species differences and modes of action.  

UK PubMed Central (United Kingdom)

Trichloroethylene (TCE) is both acutely toxic and carcinogenic to the mouse lung following exposure by inhalation. In contrast, it is not carcinogenic in the rat lung and is markedly less toxic following...Full Text Available

2000-05-01

150

Of mice and rats: key species variations in the sexual differentiation of brain and behavior  

UK PubMed Central (United Kingdom)

Mice and rats are important mammalian models in biomedical research. In contrast to other biomedical fields, work on sexual differentiation of brain and behavior has traditionally utilized comparative...Full Text Available

2010-07-01

151

New strain of mouse hepatitis virus as the cause of lethal enteritis in infant mice.  

UK PubMed Central (United Kingdom)

A new strain of mouse hepatitis virus (MHV) was isolated from pooled gut suspensions from an epizootic of lethal enteritis in newborn mice. Negative-contrast electron microscopy showed an abundance...Full Text Available

1979-05-01

152

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

Energy Technology Data Exchange (ETDEWEB)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of ...

1996-06-01

153

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

International Nuclear Information System (INIS)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our method of ...

154

MR imaging of bone marrow with gradient echo sequences. Pt. 1. Contrast conditions of phase-identical and opposed-phase gradient echo sequences. Kernspintomographische Screeninguntersuchungen des Knochenmarkes mit Gradientenecho-Sequenzen. T. 1. Kontrastverhaeltnisse phasenidentischer und phasenverschobener Gradientenecho-Sequenzen. Untersuchungen von Probanden und pathologisch-anatomischen Praeparaten  

Energy Technology Data Exchange (ETDEWEB)

Anatomical specimens and normal persons were studied by gradient echo MR imaging to determine the influence of different echo times (TE) on bone marrow contrast. First of all, six normal persons were studied to determine specific echo times for in-phase and opposed-phase states. Using different sequences bone marrow contrast in isolated femoral bones was determined and compared to results of pathological exams. Red bone marrow had no signal on opposed-phase images; contrast between red and yellow marrow was higher on opposed-phase than on in-phase images. Bone marrow lesions can be expected to be visualised with high signal on opposed-phase images; this technique should be especially suited for MR imaging of bone marrow. (orig.).

1991-06-01

155

Longitudinally and circumferentially directed movements of the left ventricle studied by cardiovascular magnetic resonance phase contrast velocity mapping  

UK PubMed Central (United Kingdom)

ObjectiveUsing high resolution cardiovascular magnetic resonance (CMR), we aimed to detect new details of left ventricular (LV) systolic and diastolic function, to explain the twisting...Full Text Available

156

Kinetic Complexity of the Global Response to Glucocorticoid Receptor Action  

UK PubMed Central (United Kingdom)

We have characterized the kinetic response of gene targets throughout the murine genome to transcriptional modulation by the glucocorticoid receptor (GR). In contrast to a model in which multiple genes...Full Text Available

2009-04-01

157

Is hepatotropic contrast enhanced MR a more effective method in differential diagnosis of hemangioma than multi-phase CT and unenhanced MR?  

UK PubMed Central (United Kingdom)

BackgroundCavernous hemangiomas are the most frequent neoplasms of the liver and in routine clinical practice they often need to be differentiated from malignant tumors and other...Full Text Available

158

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

International Nuclear Information System (INIS)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were ...

1999-09-01

159

Increased expression of cytosolic chaperonin CCT in human hepatocellular and colonic carcinoma  

Science.gov (United States)

... protein is abundant in cytosolic portions of malignant epithelial tissue (Fig. 3A). In contrast, the degree of CCTβ staining in normal epithelial tissue (Fig. 3B) or connective tissues was much weaker ......

160

Expansions, contractions, and fragility of the spinocerebellar ataxia type 10 pentanucleotide repeat in yeast  

UK PubMed Central (United Kingdom)

Spinocerebellar ataxia 10 (SCA10) is an autosomal dominant disease caused by large-scale expansions of the (ATTCT)n repeat within an intron of the human ATXN10 gene. In contrast...Full Text Available

2011-02-15

161

Evaluation of Tumor Micro-Environment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging  

UK PubMed Central (United Kingdom)

RATIONALE AND OBJECTIVESNon-invasive longitudinal imaging of tumor vasculature could provide new insights into the development of solid tumors, facilitating efficient...Full Text Available

2011-01-01

162

Evaluation of Oral Administration of Adenine to Dogs and Primates.  

Science.gov (United States)

Little change was observed in primates fed 75 mg/kg adenine over the four-week period. Minimal tissue pathology was encountered upon completion of the study. In contrast to earlier studies in which oral feeding of adenine to dogs caused severe symptoms, a...

1974-01-01

163

Enhancing fraction measured using dynamic contrast-enhanced MRI predicts disease-free survival in patients with carcinoma of the cervix  

UK PubMed Central (United Kingdom)

Background:There is a need for simple imaging parameters capable of predicting therapeutic outcome.Methods:This retrospective study analysed 50 patients...Full Text Available

2010-01-05

164

Enhanced CT and CT virtual endoscopy in diagnosis of heterotopic pancreas  

UK PubMed Central (United Kingdom)

AIM: To improve the diagnosis of heterotopic pancreas by the use of contrast-enhanced computed tomography (CT) imaging and CT virtual endoscopy (CTVE).METHODS: A total of six patients with heterotopic...Full Text Available

2011-09-07

165

Effect of Edge-Preserving Adaptive Image Filter on Low-Contrast Detectability in CT Systems: Application of ROC Analysis  

UK PubMed Central (United Kingdom)

Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available

2008-01-01

166

Dual Energy and Low kVp CT in the Abdomen  

UK PubMed Central (United Kingdom)

Low kVp settings provide high conspicuity of contrast materials at CT but may result in high image noise, particularly in larger patients. Material decomposition at dual energy CT can differentiate...Full Text Available

2009-07-01

167

Dimeric subunit stoichiometry of the human voltage-dependent proton channel Hv1  

UK PubMed Central (United Kingdom)

In voltage-gated Na+, K+, and Ca2+ channels, four voltage-sensor domains operate on a central pore domain in response to membrane voltage. In contrast, the voltage-gated...Full Text Available

2008-06-03

168

Differing in vitro Survival Dependency of Mouse and Rat NG2+ Oligodendroglial Progenitor Cells  

UK PubMed Central (United Kingdom)

NG2 chondroitin sulfate proteoglycan is a surface marker of oligodendroglial progenitor cells (OPCs) in various species. In contrast to well-studied rat OPCs, however, we found that purified...Full Text Available

2010-04-01

169

Development of melanopsin-based irradiance detecting circuitry  

UK PubMed Central (United Kingdom)

BackgroundMost retinal ganglion cells (RGCs) convey contrast and motion information to visual brain centers. Approximately 2% of RGCs are intrinsically photosensitive (ipRGCs), express...Full Text Available

170

Cross-sectional Specimen Preparation and Observation of a Plasma Sprayed Coating Using a Focused Ion Beam/Transmission Electron Microscopy System.  

Science.gov (United States)

A focused ion beam (FIB) technique was applied to cross-sectional specimen preparation to observe an interface between a plasma sprayed coating and an aluminum (Al) substrate by transmission electron microscopy (TEM). The surface of the sprayed coating film has a roughness of several tens of microns. Sputter rates for the coating film and the substrate are greatly different. The rough surface and the difference in sputter rate cause problems in making TEM specimens with smooth side walls. The top surface of the coating film was planerized by the FIB before fabricating the TEM specimen. The interfaces were investigated by TEM and energy-dispersive X-ray (EDX) analysis. The TEM observation revealed that there is a 10 nm thick amorphous layer at the interface between the coating film and substrate. The coating film consists of two kinds of sublayers with bright and dark contrast. The bright contrast sublayers were amorphous layers with thickness ...

2000-05-01

171

Contrasting Population Structures of the Genes Encoding Ten Leading Vaccine-Candidate Antigens of the Human Malaria Parasite, Plasmodium falciparum  

UK PubMed Central (United Kingdom)

The extensive diversity of Plasmodium falciparum antigens is a major obstacle to a broadly effective malaria vaccine but population genetics has rarely been used to guide vaccine design....Full Text Available

172

Comparing and Contrasting the Roles of AMPK and SIRT1 in Metabolic Tissues  

UK PubMed Central (United Kingdom)

The ability to adapt and respond to nutrients is an ancient cellular function, conserved from unicellular to the most complex multicellular organisms, including mammals. Mammals adapt to changes...Full Text Available

2008-12-01

173

Comparative aspects of cortical neurogenesis in vertebrates  

UK PubMed Central (United Kingdom)

The mammalian neocortex consists of six layers. By contrast, the reptilian and avian cortices have only three, which are believed to be equivalent to layers I, V and VI of mammals. In mammals, the majority...Full Text Available

2007-08-01

174

Common genetic variation and susceptibility to partial epilepsies: a genome-wide association study  

UK PubMed Central (United Kingdom)

Partial epilepsies have a substantial heritability. However, the actual genetic causes are largely unknown. In contrast to many other common diseases for which genetic association-studies have successfully...Full Text Available

2010-07-01

175

Colour television, an imitation of the human visual system.  

UK PubMed Central (United Kingdom)

Colour television is examined as an attempt to imitate the human visual system in image formation, spectral sensitivities, adaptation, contrast effects, signal processing, signal modulation, signal...Full Text Available

1975-07-01

176

Bimodal MR-PET agent for quantitative pH imaging  

UK PubMed Central (United Kingdom)

Activatable or “smart” magnetic resonance contrast agents have relaxivities that depend on environmental factors such as pH or enzymatic activity, but the MR signal depends on...Full Text Available

2010-03-22

177

Alteration of the chemical environment disrupts communication in a freshwater fish  

UK PubMed Central (United Kingdom)

It is well established that changes to the chemical environment can impair development, physiology and reproductive biology; by contrast, impacts on communication have not been widely reported. This...Full Text Available

2006-05-22

178

Age-Related Deterioration of Rod Vision in Mice  

UK PubMed Central (United Kingdom)

Even in healthy individuals, aging leads to deterioration in visual acuity, contrast sensitivity, visual field, and dark adaptation. Little is known about the neural mechanisms that drive the...Full Text Available

2010-08-18

179

Cerebral angiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Eighty-seven subtraction images of FCR were compared with subtraction images of conventional angiography. Although FCR images with reduced exposure dose (25 % of regular dose) and with diluted contrast material (150 mgI/ml, 50 % of usual concentration) were slightly inferior to the images of conventional angiography, most clinically important vessels were adequately visualized. As FCR has wider dynamic range and higher contrast resolution than conventional angiography, FCR may take over conventional angiography. (author).

1985-01-01

180

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-06-01

181

Experimental and clinical studies on the usefulness and assessment of the angiographic images processed by a digital radiography system (FCR: Fuji Computed Tomography)  

International Nuclear Information System (INIS)

The purpose of this study was to assess experimentally and clinically the usefulness of Fuji Computed Radiography (FCR) in angiographic examinations. FCR had a spatial resolution with much lower X-ray exposure doses, although the resolution of FCR was generally inferior to conventional films. When a contrast medium of 1% iodine concentration was used, FCR pinpointed a mass 1.5 mm in diameter; and conventional film could detect a mass 2.2 mm in diameter. The contrast of iodine in FCR examinations was stable. A high sensitivity of imaging plate allowed a wide range of visualization. In 148 selective angiographic examinatinons for 138 patients, FCR-subtraction images were superior to conventional film angiography for contrast resolution; it had a high sensitivity in detecting areas, such as the mediastimun and left lobe of the liver, and tumor stains in capillary phase. The capability of FCR arteriogram was as good as film ...

1989-01-01

182

A simplified method of opacifying and mixing acrylic cement for percutaneous vertebroplasty: a clinical and in vitro study.  

Science.gov (United States)

The objective of this study was to simplify the opacifying mixing process of the bone cement and contrast used for percutaneous vertebroplasty (PVP). We performed a biomechanical study of polymethyl methacrylate (PMMA) (Corinplast 3) using three different mixtures of PMMA, monomer, and contrast: group I, 2:1; group II, 3:2; group III, 3:2:1 ratio of powder/monomer/iodinated contrast (Omnipaque). In vitro biomechanical testing of ultimate compressive strength was carried out in all samples. Following the conclusion of a proper bone cement mixture regimen drawn from the in vitro study, PVP was performed in 125 patients: 58 with cancer, 12 with hemangioma, and 54 with osteoporotic fracture. The ultimate compressive strength in group III was decreased by 38% compared to groups II and I. Proper fluoroscopic visualization was achieved in all PVP procedures using this mixture. There were no major complications associated with ...

183

A Simplified Method of Opacifying and Mixing Acrylic Cement for Percutaneous Vertebroplasty: A Clinical and In Vitro Study  

Science.gov (United States)

The objective of this study was to simplify the opacifying mixing process of the bone cement and contrast used for percutaneous vertebroplasty (PVP). We performed a biomechanical study of polymethyl methacrylate (PMMA) (Corinplast{sup TM} 3) using three different mixtures of PMMA, monomer, and contrast: group I, 2:1; group II, 3:2; group III, 3:2:1 ratio of powder/monomer/iodinated contrast (Omnipaque). In vitro biomechanical testing of ultimate compressive strength was carried out in all samples. Following the conclusion of a proper bone cement mixture regimen drawn from the in vitro study, PVP was performed in 125 patients: 58 with cancer, 12 with hemangioma, and 54 with osteoporotic fracture. The ultimate compressive strength in group III was decreased by 38% compared to groups II and I. Proper fluoroscopic visualization was achieved in all PVP procedures using this mixture. There were no major complications associated ...

2005-06-15

184

Three-dimensional evaluation of cartilage thickness and cartilage volume in the knee joint with MR imaging: reproducibility in volunteers; Dreidimensionale Dicken- und Volumenbestimmung des Kniegelenkknorpels mit der MRT: Reproduzierbarkeit am Probanden  

Energy Technology Data Exchange (ETDEWEB)

Objective: To determine the reproductibility of three-dimensional volume and thickness measurements of the knee joint cartilage with MRI in volunteers. Methods: The knees of 7 healthy individuals (ages 23 to 58 yrs.) were sagitally imaged with a resolution of 2x0.31x0.31 mm{sup 3}, using a fat-suppressed FLASH-3 D sequence. The knee was repositioned in between replicate acquisitions, 6 data sets being obtained in each case. After semiautomatic segmentation and three-dimensional reconstruction of the cartilage, the thickness was determined independent of the original section orientation. The coefficient of variation for repeated volume measurements and the deviations of the maximal cartilage thickness values were calculated subsequently. Results: The mean variation of the cartilage volumes of the replicate measurements was 1.4% ({+-}0.8%) in the patella, 1.7% ({+-}1.5%) in the femur, 3.0% ({+-}1.2%) in the medial tibial plateau and 3.5% ({+-}2.0%) in the lateral tibial plateau. The ...

1997-12-01

185

Magnetic resonance imaging (MRI) of the central nervous system in long-term manganese dioxide (MnO{sub 2}) exposed workers; Magnetresonanztomographie des Gehirns bei Beschaeftigten mit chronischer beruflicher Mangandioxid-Exposition  

Energy Technology Data Exchange (ETDEWEB)

Aim: Changes within the brain detected by MRI after chronic manganese poisoning raised the question whether morphological changes of the basal ganglia, particularly of the globus pallidus, could be detected after chronic occupational exposure to manganese dioxide. Results: No cases of parkinsonism were detected in clinical examinations or by other means. The mean manganese concentration in blood was 12 {mu}g/l (range: 3.9-23.3 {mu}g/l). In comparison to the upper reference value of 10 {mu}g/l, 42 workers (56%) had a higher body burden. A significant positive correlation between manganese levels in blood and the PI (indicated by T{sub 1}-shortening) was observed as well as between the CBI and workplace-specific exposure. Brain atrophy was not detected in any of the observed cases. Conclusions: Long-term exposure to manganese dioxide dust correlates with the Pallidum-Index in MRI scans. Although the MRI findings have no current clinical relevance for individuals, further studies are ...

2000-06-01

186

T{sub 1} and T{sub 2} relaxivities of succimer-coated MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

Energy Technology Data Exchange (ETDEWEB)

Superparamagnetic MFe{sub 2}{sup 3+}O{sub 4} (M=Mn{sup 2+}, Fe{sup 2+} and Co{sup 2+}) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r{sub 2}/r{sub 1}, for MnFe{sub 2}O{sub 4}, Fe{sub 3}O{sub 4} and CoFe{sub 2}O{sub 4} were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T{sub 2} contrast agents for MRI.

2009-12-15

187

T1 and T2 relaxivities of succimer-coated MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrites for potential use as phase-contrast agents in medical MRI  

International Nuclear Information System (INIS)

Superparamagnetic MFe23+O4 (M=Mn2+, Fe2+ and Co2+) inverse spinel ferrite (ISF) nanoparticles with narrow size distribution having average diameters of 6-8 nm were synthesized by a diol reduction of organic metals and the surface was modified to be hydrophilic by coating with succimer. Magnetic resonance imaging (MRI) contrast enhancement by dipolar coupling defined interactions between the synthesized ISFs and protons in the bulk water was investigated with initial susceptibility, magnetization and anisotropy of the succimer-coated ISFs. The relaxivity ratios, r2/r1, for MnFe2O4, Fe3O4 and CoFe2O4 were measured to be 12.2, 23.1 and 62.3, respectively, which demonstrate the potential usefulness of these magnetic nanoparticles as T2 contrast agents for MRI.

2009-12-01

188

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast images are extracted from experimental projection images by an ...

2006-08-01

189

MR imaging of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Magnetic resonance (MR) images of 18 cases of hilar cholangiocarcinoma were evaluated to compare the effectiveness of Gd-DTPA with that of high dose contrast enhancement computed tomography (HCE-CT) in detecting the primary tumor. The primary tumor was demonstrated as having slightly low intensity compared with liver parenchyma and high intensity compared with the delated bile duct on T1-weighted images. In contrast, MRI using Gd-DTPA, which was carried out in five cases, revealed intense enhancement of the tumor. As the differentiation between cholangiocarcinoma and dilated bile duct was difficult, it was concluded that the use of Gd-DTPA improves the efficacy of MRI in diagnosing cholangiocarcinoma. Gd-DTPA was also effective in differentiating the growth pattern of the tumor: the infiltrating type was demonstrated as thickening of the wall of the bile duct, the polypoid type as a soft tissue mass in the bile duct. ...

190

Lasing efficiency and tuning range of a dynamic distributed-feedback laser  

Energy Technology Data Exchange (ETDEWEB)

The effects of the contrast of the pump field interference pattern, that is, the effectiveness of the dynamic amplitude-phase grid, and various optical arrangements on the lasing efficiency and tuning range of a dynamic distributed-feedback dye laser are investigated. It is shown that the proper choice of prism apex angle, prism material and dye solvent in a laser in the range 400-1000 microns pumped by two beams of different intensity directed through the congruent sides of an isosceles prism in contact with the active medium solution on its third side can lead to optical losses of less than 2% from the boundaries of the prism. Measurements of polymethine dye laser efficiency and tuning range as a function of the relative intensity of the two ruby-laser pump beams reveals that as the contrast of the pump beam interference pattern decreases, the tuning range remains practically constant and the efficiency increases in the nonlinear (saturation) ...

1980-08-01

191

Gd-25 DTPA-MAb, a potential NMR contrast agent for MRI in the xenografted nude mouse: preliminary studies  

Energy Technology Data Exchange (ETDEWEB)

Monoclonal antibodies (MAbs) 19-9 and 73-3 specific for human colon adenocarcinoma were labelled with a high number of gadolinium atoms. Twenty five DTPA were chelated per MAb, with only slight loss of immunoreactivity. The NMR contrast agent Gd-25 DTPA-MAb 19-9 or 73-3 ((Gd) 17 mumole/kg, (MAb) 60 microM) was injected into nude mice bearing human colon adenocarcinoma (SW948). Tumors were removed 24 hr after injection and T1 was measured in vitro. T1 relaxation time varied according to MAb specificity against tumour targets; T1 decreased 20% for MAb 19-9 and MAb 73-3 with SW948 tumor. Imaging was performed with this model. Very good contrast was obtained 24 hr after Gd-25 DTPA-MAb injection.

1988-01-01

192

Fluorescence based molecular in vivo imaging; Fluoreszenzgestuetzte molekulare Bildgebung in vivo  

Energy Technology Data Exchange (ETDEWEB)

Molecular imaging represents a modern research area that allows the in vivo study of molecular biological process kinetics using appropriate probes and visualization methods. This methodology may be defined- apart from the contrast media injection - as non-abrasive. In order to reach an in vivo molecular process imaging as accurate as possible the effects of the used probes on the biological should not be too large. The contrast media as important part of the molecular imaging can significantly contribute to the understanding of molecular processes and to the development of tailored diagnostics and therapy. Since more than 15 years PTB is developing optic imaging systems that may be used for fluorescence based visualization of tissue phantoms, small animal models and the localization of tumors and their predecessors, and for the early recognition of inflammatory processes in clinical trials. Cellular changes occur during many diseases, thus the ...

2008-12-15

193

Evaluation of selective alveolo-bronchography with Fuji computed radiography and x-ray CT  

International Nuclear Information System (INIS)

Selective alveolo-bronchography (SAB) has been routinely used to evaluate anatomical changes in the bronchiole and its distal air spaces. A narrowing of the bronchiole and abnormal pooling of contrast medium in the destroyed air space are the prime findings. Since the object of radiography is extremely thin, direct magnification radiography is mandatory to obtain radiologic details. However, the problem with this technique is that radiographic quality varies depending upon the size of the patient and the concentration of contrast medium to be introduced in the lung. This study had two goals. One was to improve the image quality of SAB by Fuji Computed Radiography (FCR). FCR provides radiographs with a good contrast and stable density throughout a wide range of exposure factors which occur in the use of SAB. The other goal was to separately evaluate morphological abnormalities in the outer and inner zones of the lung using ...

1986-01-01

194

Evaluation of computer-aided detection of lesions in mammograms obtained with a digital phase-contrast mammography system  

Energy Technology Data Exchange (ETDEWEB)

A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-{mu}m-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of breast cancer in its ...

2009-12-15

195

Computed tomography and magnetic resonance imaging of acquired abnormalities of the inner ear and cerebello-pontine angle  

International Nuclear Information System (INIS)

CT and MRI of acquired abnormalities of the inner ear and cerebello-pontine angle present themselves with very typical findings. The imaging should be adapted to the pathology looked for and either CT or MRI should be used alone or in combination.CT, especially high resolution CT (HRCT), provides an excellent bone contrast, while MRI has a much superior soft tissue contrast. Acute inflammatory changes of the inner ear are solely depicted by contrast-enhanced MRI. HRCT excellently depicts osseous changes of the inner ear and cerebellopontine angle such as chronic ossifying labyrinthitis occurring after acute labyrinthitis, otosclerotic or traumatic changes. Tumorous changes not yielding to bony changes are best delineated by MRI. Posttraumatic hemorrhage and chronic fibrotic changes within the labyrinth are depicted by MRI, only. In conclusion HRCT and MRI are excellent methods to delineate acquired abnormalities of the ...

2003-03-01

196

StoRHm: a protocol adapter for mapping SOAP based Web Services to RESTful HTTP format  

British Library Electronic Table of Contents (United Kingdom)

A protocol adapter ideally suited to enable enterprises to gradually transition from SOAP Web Services to RESTful HTTP Web Services without impacting existing clients is presented in this paper. The inherent advantage of such a transition is the visibility of RESTful HTTP messages to Web intermediaries such as caches. In contrast, SOAP messages are opaque, which disables Web intermediaries. While both approaches can use HyperText Transfer Protocol (HTTP) for message transfer, the paradigms contrast sharply. SOAP uses an interface specific approach whereas RESTful HTTP uses a Uniform Interface approach. SOAP marks up its payload with eXtensible Markup Language (XML) whereas in certain situations RESTful HTTP requires no XML. We present the disadvantages of the SOAP approach and outline how ...

2011-01-01

197

Role of MRI in the diagnostic evaluation of parotid diseases  

International Nuclear Information System (INIS)

MRI findings in 13 patients with monolateral parotid tumor were compared with US, sialographic and CT findings. MRI did not allow an accurate diagnosis in 2 patients with diffuse chronic parotitis. MRI was superior to CT in 1 case in defining the intraglandular site of the lesion, and in 2 patients in showing the extraglandular involvement. MRI proved to be superior to CT thanks to its contrast resolution and to multiplanar imaging. MRI high contrast resolution made it possible to demonstrate neoplastic lesions of 4 mm in diameter. The lesion has low signal intensity on T1-weighted images and high signal intensity on T2-weighted. Parotid tumors cannot be characterized by signal intensity alone: only morphology allows to discriminate between benign and malignant lesions. To conclude, US is a screening method, while MRI is helpful in detecting multifocal lesions and in evaluating the tumor extent.

1988-01-01

198

Response of ecosystem carbon exchange to warming and nitrogen addition during two hydrologically contrasting growing seasons in a temperate steppe  

British Library Electronic Table of Contents (United Kingdom)

Abstract A large remaining source of uncertainty in global model predictions of future climate is how ecosystem carbon (C) cycle feedbacks to climate change. We conducted a field manipulative experiment of warming and nitrogen (N) addition in a temperate steppe in northern China during two contrasting hydrological growing seasons in 2006 [wet with total precipitation 11.2% above the long-term mean (348 mm)] and 2007 (dry with total precipitation 46.7% below the long-term mean). Irrespective of strong intra- and interannual variations in ecosystem C fluxes, responses of ecosystem C fluxes to warming and N addition did not change between the two growing seasons, suggesting independence of warming and N responses of net ecosystem C exchange (NEE) upon hydrological variations in the temperate ...

2009-01-01

199

Raney-platinum film electrodes for potentially implantable glucose fuel cells. Part 1: Nickel-free glucose oxidation anodes  

British Library Electronic Table of Contents (United Kingdom)

We present a novel fabrication route yielding Raney-platinum film electrodes intended as glucose oxidation anodes for potentially implantable fuel cells. Fabrication roots on thermal alloying of an extractable metal with bulk platinum at 200^oC for 48h. In contrast to earlier works using carcinogenic nickel, we employ zinc as potentially biocompatible alloying partner. Microstructure analysis indicates that after removal of extractable zinc the porous Raney-platinum film (roughness factor ~2700) consists predominantly of the Pt3Zn phase. Release of zinc during electrode operation can be expected to have no significant effect on physiological normal levels in blood and serum, which promises good biocompatibility. In contrast to previous anodes based on hydrogel-bound catalyst particles the ...

2010-01-01

200

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

201

Opportunistic esophagitis in AIDS: Radiographic diagnosis  

International Nuclear Information System (INIS)

Between 1983 and 1986, 35 of 90 patients with acquired immunodeficiency syndrome (AIDS) had double-contrast esophagograms to rule out opportunistic esophagitis. The radiographs were reviewed without knowledge of the clinical or endoscopic findings. Candida esophagitis was diagnosed radiographically in 17 patients who had varying degrees of plaque formation and viral esophagitis in three who had discrete ulcers without plaques. All three patients with viral esophagitis (herpes in 2 and cytomegalo virus in one) and 15 of 17 with Candida esophagitis had endoscopic and/or clinical corroboration of the radiographic diagnosis. Thus, the authors' experience suggests that fungal and viral esophagitis can often be differentiated on double-contrast esophagography, so that appropriate antifungal or antiviral therapy can be instituted without need for endoscopic intervention.

202

Lacrimal gland masses on CT and MRI: a report of four cases  

International Nuclear Information System (INIS)

In an extended case report, we discuss four cases with masses in the lacrimal fossa representing the most important entities in this region (lymphoma, pleomorphadenoma, inflammatory pseudotumor, and malignant epithelial tumor). The different indications for CT and MRI are explained. For the differential diagnosis of lacrimal gland lesions, the following imaging parameters are important: The shape of the lacrimal gland, the inner structure, the degree of contrast enhancement, and the surrounding bony structures. In the evaluation of the expansion of lacrimal gland lesions, CT in thin slices with multiplanar reconstructions is equal to MRI. However, the contrast-enhancement of lacrimal glands is better evaluated with MRI than with CT. The bony structures are better visualized on CT than on MRI. (orig.).

203

Fetal magnetic resonance imaging of the brain: technical considerations and normal brain development  

International Nuclear Information System (INIS)

Fetal MRI examines non-invasively the unborn fetus. Ultrafast MRI sequences effectively suppress fetal motion. Multiple case reports and studies have shown that fetal MRI is particularly helpful in the evaluation of the central nervous system. The high contrast-to-noise ratio, the high spatial resolution, the multiplanar capabilities, the large field of view and the simultaneous visualisation of fetal and maternal structures have proven to be advantageous. Fetal MRI is particularly helpful in the evaluation of the normal and pathological development of the brain. Despite the fact that no side effects have been reported or are to be expected, the use of MRI during pregnancy is still limited to the second and third trimester of pregnancy. Magnetic resonance imaging contrast media are not to be used as it passes the placenta. Ultrasound remains the primary screening modality for fetal pathology; fetal MRI can serve as an adjunct or second-line ...

2002-08-01

204

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

205

Ewing's sarcoma recurrence vs radiation necrosis in dynamic contrast-enhanced MR imaging: a case report  

International Nuclear Information System (INIS)

Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)

1999-04-01

206

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively.

1985-01-01

207

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively. (orig.).

1985-01-01

208

Angiography of the head using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).

1985-01-01

209

Rational imaging strategies in larynx disease; Rationelle bildgebende Strategien bei Kehlkopferkrankungen  

Energy Technology Data Exchange (ETDEWEB)

Clinical information is indispensable for swift and cost-effective clarification of diseases of the larynx. While quality clarification of neurological changes in the area of the posterior cranial fossa and in the course of the vagus nerve as a cause of glottis malfunction is possible with MRI, localized disease of the larynx can more effectively be assessed with low-artifact CT. In the particularly difficult assessment of the post-operative larynx, a recurrence can be diagnosed only after a baseline study has been carried out after the end of therapy. With knowledge of the pretherapeutic findings, the findings immediately post-therapy, and the operation technique used, the optimal CT examination, which can be carried out quickly, will be able to provide more information about recurrence. (orig.) [Deutsch] Zur schnellen und kostenguenstigen Abklaerung von Erkrankungen des Larynx ist die klinische Information unabdingbar: Wenn neurologische Veraenderungen im Bereich der hinteren ...

1998-02-01

210

Morphometric analysis of the temporomandibular joint with MRI in 320 joints; Morphometrische Analyse des Kiefergelenkes anhand von 320 Gelenken mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Purpose: to compare several morphometric parameters in MRI with the functional status of the articular disc in a large patient group suffering from internal derangement (ID) of the temporomandibular joint (TMJ). Materials and methods: in a retrospective study, 320 analyzable high resolution MRI examinations of the TMJs obtained in a 1.5 T unit were evaluated in 184 patients with clinically suspected ID. The analysis included the anatomical structures and a number of morphometric parameters previously described in the literature. The parameters were compared with the position of the articular disc. Results: the disc position was categorized as ''normal'' (NDP, 21.9%, n = 70), ''anterior displacement with reduction on opening'' (AMR, 51.6%, n = 165) and ''anterior displacement without reduction on opening'' (AOR, 26.6%, n = 85). With increasing disc displacement, significant ...

2005-02-01

211

Wind instability of a foam layer sandwiched between the atmosphere and the ocean  

CERN Document Server

Kelvin-Helmholtz instability of short gravity waves is examined in order to explain the recent findings of the decrease in momentum transfer from hurricane winds to sea waves. A three-fluid configuration of a foam layer between the atmosphere and the ocean is suggested to provide signifficant stabilization of the system and shifting the marginal critical wavelength to the shortwave part of the spectrum. It is conjectured that such stabilization leads to the observed drag reduction. The high contrasts in three fluid densities provide a universal mechanism for stabilizing surface perturbations.

2007-01-01

212

Variosorb - advanced gas sorption with powder sorbent technology  

Energy Technology Data Exchange (ETDEWEB)

In contrast to plants based on formed coal where, for the purposes of calculating sorbent volume, only one activated charcoal design can be used in a filter layer, powder sorbent technology enables two variations to be used. This can be either a mixture of a number of different activated charcoal forms in one and the same filter layer, or the combination of a number of filter layers on top of each other, each containing a different activated charcoal form, in one and the same construction unit.

1983-01-01

213

The different structural scales of the breast and their impact on time-of-flight and diffraction tomography  

Energy Technology Data Exchange (ETDEWEB)

Ultrasound tomography is an attractive imaging method for the detection of breast cancer. The complex anatomy of the breast with its different spatial scales and material property contrasts make accurate reconstructions very challenging. This paper proposes a hybrid approach whereby Travel-of-Flight and Diffraction Tomography are combined together to achieve high-resolution and high-accuracy sound-speed reconstructions. The method is validated with several numerical phantoms.

2010-01-01

214

The Percus-Yevick theory is alive and well  

Science.gov (United States)

The pressure of a 6:12 fluid is obtained from the Percus-Yevick theory at the temperature kT/? = 1.35. The energy equation results are in excellent agreement with machine calculation results in contrast to the pressure and compressibility equation results. Present address: Diffusion Research Unit, The Australian National University, Canberra, ACT, Australia.

1970-01-01

215

Simulations of dual morphology in spiral galaxies  

CERN Document Server

Gas and stars in spiral galaxies are modelled with the DUAL code, using hydrodynamic and N-body techniques. The simulations reveal morphological differences mirroring the dual morphologies seen in B and K' band observations of many spiral galaxies. In particular, the gaseous images are more flocculent with lower pitch angles than the stellar images, and the stellar arm-interarm contrast correlates with the degree of morphological decoupling.

2003-01-01

216

Quantum tachyons in Schwarzschild space-time  

Energy Technology Data Exchange (ETDEWEB)

The wave equation of a spinless tachyon is studied in Schwarzschild space-time. In contrast to earlier approaches to the problem, it is shown that tachyonic static solutions satisfy a simple second-order linear differential equation regardless of the mass of the black hole and the mass parameter of the tachyon. Physical implication of the present approach is discussed. Using Langer modification of the WKB (Wentzel-Kramers-Brillouin) boundary condition an expression similar to the Bohr-Sommerfeld quantization condition is derived.

1981-02-01

217

Prolactin and Its Receptor Are Expressed in Murine Hair Follicle Epithelium, Show Hair Cycle-Dependent Expression, and Induce Catagen  

UK PubMed Central (United Kingdom)

Here, we provide the first study of prolactin (PRL) and prolactin receptor (PRLR) expression during the nonseasonal murine hair cycle, which is, in contrast to sheep, comparable with the human scalp...Full Text Available

2003-05-01

218

Phase-plate electron microscopy: a novel imaging tool to reveal close-to-life nano-structures  

UK PubMed Central (United Kingdom)

After slow progress in the efforts to develop phase plates for electron microscopes, functional phase plate using thin carbon film has been reported recently. It permits collecting high-contrast images...Full Text Available

2009-03-01

219

Non-selective cervical and cerebral three-dimensional rotational angiography  

International Nuclear Information System (INIS)

To evaluate the usefulness of three-dimensional (3D) rotational angiography, cervical carotid or cerebral angiography was done without catheterizing the branches of the thoracic aorta. A 5-Fr pig-tail type catheter was passed into the ascending aorta via the radial artery or the femoral artery. Optimal carotid angiogram views were obtained using approximately 45 ml of contrast medium at a flow rate of 15 ml/sec. Optimal cerebral angiogram views were obtained using approximately 70 ml of contrast medium at a flow rate of 20 ml/sec. The contrast medium concentration was 300 to 350 mgI/ml. A satisfactory view could be obtained in 5 of 8 (63%) cases on cervical carotid 3D angiography and in 8 of 14 (57%) cases on cerebral 3D angiography. In all cases, no complications were noted. This method offers the advantages of requiring a relatively short procedure time and a decrease in radiation exposure. Further studies are needed to ...

2007-09-01

220

Neutron-computer tomography using real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the ...

1986-01-01

221

Neutron-computer tomography using real-time neutron radiography  

International Nuclear Information System (INIS)

A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography algorithms, the simultaneous iterative reconstruction technique (SIRT) and the convolution method, were ...

1986-01-01

222

Neutron radiography with the cyclotron, 6  

International Nuclear Information System (INIS)

The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).

1988-01-01

223

Modeling Transient Discharge into a Tunnel Drilled in a Heterogeneous Formation  

British Library Electronic Table of Contents (United Kingdom)

Abstract An analytical model is developed to predict transient discharge flow into a tunnel drilled at various speeds through a heterogeneous formation. This model relies on simplifying assumptions commonly enforced in hydrogeologic engineering, and combines the convolution and superposition principles to account for composite sections with arbitrary parametric contrasts. An application to the data monitored during the exploratory drilling of an Alpine tunnel confirms the validity of the approach.

2007-01-01

224

Measurement of the Self-Diffusion Coefficient of Water as a Function of Position in Wheat Grain Using Nuclear Magnetic Resonance Imaging  

UK PubMed Central (United Kingdom)

A pulsed field gradient spin echo sequence has been incorporated in a nuclear magnetic resonance (NMR) imaging experiment to provide an image contrast dependent on local molecular self-diffusion. The...Full Text Available

1988-01-01

225

Maximum imaging depth of two-photon autofluorescence microscopy in epithelial tissues  

Science.gov (United States)

Endogenous fluorescence provides morphological, spectral, and lifetime contrast that can indicate disease states in tissues. Previous studies have demonstrated that two-photon autofluorescence microscopy (2PAM) can be used for noninvasive, three-dimensional imaging of epithelial tissues down to approximately 150 ?m beneath the skin surface. We report ex-vivo 2PAM images of epithelial tissue from a human tongue biopsy down to 370 ?m below the surface. At greater than 320 ?m deep, the fluorescence generated outside the focal volume degrades the image contrast to below one. We demonstrate that these imaging depths can be reached with 160 mW of laser power (2-nJ per pulse) from a conventional 80-MHz repetition rate ultrafast laser oscillator. To better understand the maximum imaging depths that we can achieve in epithelial tissues, we studied image contrast as a function of depth in tissue phantoms with a range of relevant ...

2011-02-01

226

MAGNETIC ELECTRON MICROSCOPE UEMB-100  

Science.gov (United States)

A new magnetic electron microscope, UEMB-100, was designed with an increased electron-optical parameter. The electron-optical system consists of an electron canon (the high voltage is supplied by armored lead) and condensed, objective, intermediate, and projection lenses. In contrast to other native apparatuses, the microscope has a high resolving property (up to 20A) snnd great universality. (tr-auth)

1958-07-01

227

Lung studies with spiral CT. pitch 1 versus pitch 2  

International Nuclear Information System (INIS)

In Spiral CT, the pitch is the ratio of the distance to tabletop travels per 360 degrees rotation to nominal slice width, expressed in mm. Performing Spiral CT examination with pitch 2 allows to reduce examination time, exposure and contrast dose, and X-ray tube overload. The authors investigated the yield of pitch 2 in lung parenchyma studies, particular relative to diagnostic image quality.

1999-03-01

228

Laser weapons. II - Strategic laser weapons  

Science.gov (United States)

Potential strategic missions for laser weapons, particularly those involving space-based lasers, are discussed. The functions of space-based lasers and the history of their conceptual development are summarized, and the problems of implementing such systems, including the building of a suitable laser and power source, and resolving the problem of optics, are discussed. Ongoing development programs are described, and the contrasting views of the necessity and usefulness of strategic laser systems are set forth.

1982-07-01

229

Kinetic estimation of infused Lipiodol within hepatoma using CT dynamic study  

Energy Technology Data Exchange (ETDEWEB)

Distribution of Lipiodol within hepatic tumor was evaluated using serial computed tomography. Imagistic Lipiodol transition into the tumor via hepatic artery was slower than that of water soluble contrast medium, spreading to central part first and turn to peripheral part of the tumor. This method was thought to be useful to clarify Lipiodol distribution in hepatic tumor and to decide the method or necessity of additional trans-arterial therapy. (author).

1991-02-01

230

Iodixanol in cerebral computed tomography: a randomized, double-blind, phase-III, parallel study with iodixanol and iohexol  

Energy Technology Data Exchange (ETDEWEB)

Iodixanol is a new nonionic dimer, isotonic with blood at all clinically relevant concentrations. Iodixanol (270 mg I/ml) was compared in a double-blind, randomized, parallel-group, phase-III study to the monomeric nonionic iohexol (300 mg I/ml) for evaluation of safety, tolerability and radiographic efficacy during cerebral CT. One hundred adult patients scheduled to undergo contrast-enhanced cerebral CT were randomly allocated to receive either iodixanol or iohexol. All completed the trial. Safety was evaluated by recording discomfort and other adverse events, tolerance by assessing intensity and incidence of discomfort. Radiographic efficacy was assessed from the diagnostic information and the radiographic density. No serious adverse events occurred. One patient (2 %) in the iodixanol group and one patient (2 %) in the iohexol group experienced a transient reddening at the neck and lower neck-line, respectively. Both contrast agents were ...

1999-09-01

231

Instantaneous energy density as a feature for gear fault detection  

Science.gov (United States)

In this work, energy-based features for gear fault diagnosis and prediction are proposed. The instantaneous energy density is shown to obtain high values when defected teeth are engaged. Three methods are compared in terms of sensitivity, reliability and computation effectiveness. The Wigner Ville distribution is contrasted to the wavelet transform and the newly proposed empirical mode decomposition scheme. It is shown that all three methods are capable of a reliable prediction. An empirical law, which relates the energy content to the crack magnitude is established.

2006-07-01

232

Implications of biodiversity of short rotation coppice  

Environmental Research Database

DescriptionFossil fuels have a detrimental effect on the environment. They lead to the increase in atmospheric carbon dioxide which has been documented over the last 150 years. In contrast, some sources of renewable energy are near carbon neutral. Renewable energy produced from biomass constitutes such a type of energy and so has many potential advantages. The Energy White Paper (DTI et al., 2003) identifies bioenergy as an important means of meeting the Government's energy and environment objectives, in [continued...

2009-01-31

233

IDEAS: Journal of International Trade & Economic Development, Taylor and Francis Journals  

Wastenet

... (restricted)] 101-127 On the transmission of exchange rate fluctuations to the macroeconomy: Contrasting evidence for developing and developed countries by Magda Kandil [Downloadable! (restricted)] 2005, Volume 14, Issue 4 377-405 Predicting the poverty impacts of trade reform by Thomas Hertel & Jeffrey Reimer [Downloadable! (restricted)] 407-435 Sustaining imperfectly credible trade liberalization: Do the rate of tariff reduction ...

234

How to decorate FIB cross sections using plasma etch for SEM observation  

Energy Technology Data Exchange (ETDEWEB)

The Focused-Ion-Beam (FIB) is a powerful tool for fast, precision cross-sectioning and inspection of submicron defects in multilayered integrated circuit devices. However, the low contrast between the layers in FIB cross-sections can make the feature of interest difficult to observe, which has become a limitation for FIB cross-sectioning. A technique using plasma etch to decorate the FIB cross-sections has proven to be a simple solution to overcome this limitation.

1995-12-31

235

Geosynchronous orbit magnetopause crossings  

Energy Technology Data Exchange (ETDEWEB)

In this study we extend the analysis of magnetopause crossings observed with Magnetospheric Plasma Analyzer measurements to examine a much larger statistical data set. This study examines 39 maiznetosheath/LLBL intervals from 79 spacecraft-months of observations: these observations were taken from a survey of data from the start of each spacecraft mission and extending through March 1993. In contrast to the previous findings, we find no evidence for a significant dawn/dusk asymmetry in geosynchronous magnetopause crossings.

1994-07-01

236

Features of laser damage to elastic polymers  

Energy Technology Data Exchange (ETDEWEB)

Threshold pump intensity values leading to irreversible damage to colored laser elements based on elastic polymers were measured. The damage to colored elastomers is connected with absorbing microinclusions but is independent of molecular absorption. It is shown that damage to the elastomers has a pronounced threshold character in contrast to the microdamage accumulation effect in glassy polymers. The damage threshold for elastomers is 1.5 times higher, which is connected with the absence of microstresses (characteristics for organic glasses) in the specimens. 13 references.

1988-03-01

237

Extended superconformal algebra from super Toda field theory  

International Nuclear Information System (INIS)

We propose and construct a new type of extended superconformal algebra (ESA) based on the super Toda field theory. Both in the N = 1 ESA and in the N = 2 ESA, an arbitrary value of the central charge is allowed in contrast with the previously known super W-algebra. The generators of ESA are interpreted as the constants of motion in the super Toda field theory. (orig.).

1991-01-01

238

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

Energy Technology Data Exchange (ETDEWEB)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management.

1987-03-01

239

Evaluation of peripheral vascular disease by intravenous digital subtraction angiography with the Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Intravenous digital subtraction angiography using Fuji computed radiography system (FCR-DSA) was used to evaluate 57 preoperative patients with clinical manifestations of peripheral vascular disease of lower extremity. With its high contrast resolution and good special resolution, image of FCR-DSA could offer optimal information of vascular abnormality in lower extremity distal to midfoot for the diagnosis and the choice of management. (orig.).

1987-01-01

240

Equine infectious anemia virus and human immunodeficiency virus DNA synthesis in vitro: characterization of the endogenous reverse transcriptase reaction.  

UK PubMed Central (United Kingdom)

The endogenous reverse transcriptase reaction of equine infectious anemia virus (EIAV) has been studied, and conditions allowing synthesis of full-length minus-strand DNA have been determined. In contrast...Full Text Available

1991-04-01

241

Enhancement pattern of hilar cholangiocarcinoma: Contrast-enhanced ultrasound versus contrast-enhanced computed tomography  

International Nuclear Information System (INIS)

Objective: To compare the enhancement pattern of hilar cholangiocarcinoma on contrast-enhanced ultrasound (CEUS) with that on contrast-enhanced computed tomography (CECT). Methods: Thirty-two consecutive patients with pathologically proven hilar cholangiocarcinomas were evaluated by both low mechanical index CEUS and CECT. The enhancement feature of the tumor, portal vein infiltration, and lesion conspicuity on them was investigated. Results: In the arterial phase, the numbers of the lesions showing hyperenhancement, isoenhancement, and hypoenhancement, were 14 (43.8%), 14 (43.8%), and 4 (12.6%), on CEUS, and 12 (37.5%), 9 (28.1%), and 11 (34.4%), on CECT (P = 0.162). In portal phase, the numbers of the lesions showing hypoenhancement, isoenhancement, and hyperenhancement were 30 (93.8%), 1 (3.1%), and 1 (3.1%), on CEUS, and 23 (71.9%), 8 (25.0%), and 1 (3.1%), on CECT (P = 0.046). The detection rates for portal vein infiltration were 84.2% ...

2010-08-01

242

Elucidating novel pathways and regulation of nitrogen assimilation in alpha proteobacteria exemplified by the soil organism Paracoccus denitrificans  

Environmental Research Database

DescriptionThe importance of inorganic nitrate for the nutrition and growth of marine and freshwater autotrophic phytoplankton has long been recognised, in particularly because of the 'blooms' formed in nitrate and phosphate polluted water and their possible roles as carbon dioxide sinks. By contrast, the utilisation of nitrate by heterotrophic bacteria has historically received less attention. Up until now, the primary role of heterotrophic bacteria has classically been considered to be the decomposition [continued...

2010-01-31

243

Controllable Subspaces of Open Quantum Dynamical Systems  

International Nuclear Information System (INIS)

This paper discusses the concept of controllable subspace for open quantum dynamical systems. It is constructively demonstrated that combining structural features of decoherence-free subspaces with the ability to perform open-loop coherent control on open quantum systems will allow decoherence-free subspaces to be controllable. This is in contrast to the observation that open quantum dynamical systems are not open-loop controllable. To a certain extent, this paper gives an alternative control theoretical interpretation on why decoherence-free subspaces can be useful for quantum computation.

2008-01-15

244

Computing Networks: A General Framework to Contrast Neural and Swarm Architectures  

CERN Document Server

Computing Networks (CNs) are defined. These are used to generalize neural and swarm architectures, namely artificial neural networks, ant colony optimization, and particle swarm optimization. The description of these architectures as CNs allows their comparison, distinguishing which properties enable them to perform complex computations and exhibit complex cognitive abilities. In this context, the most relevant characteristics of CNs are the existence multiple dynamical and functional scales.

2010-01-01

245

Comparative evaluation of Computed Tomography and Magnetic Resonance Imaging (1.5 T) in the detection of brain metastases  

International Nuclear Information System (INIS)

Forty-four patients with small cell carcinoma of the bronchus underwent CT and MR studies of the brain to detect cerebral metastases. All patients were studied with contrast-enhanced CT scans, short (T1-weighted) and long (T2-weighted), spin-echo (SE) and FLASH 90 grades sequences were also obtained. A quantitative comparison of the results was carried out to assess the sensitivity of the different techniques in the detection of brain metastases according to lesion diameter. Metastases were identified in 19/44 patients (43%). All techniques detected the lesions >2 cm; of the metastases <2 cm, 63/124 (51%) were detected only by GdDTPA SE-T1 and FLASH sequences and 11 more (9%) only by Gd-DTPA SE-T1 scans. All the lesions identified oh enhanced CT scans or on T2-weighted images were easily detected by Gd-DTPA scans. CT sensitivity was higher than that of pre-contrast SE-T1 and FLASH studies and only slightly lower than that of T2-weighted ...

1991-01-01

246

Collaborations in Mind, Brain, and Education: An Analysis of Researcher-Practitioner Partnerships in Three Elementary School Intervention Studies  

British Library Electronic Table of Contents (United Kingdom)

A reciprocal relationship informing both research and practice is one of the primary goals in the emerging field of Mind, Brain, and Education (MBE), yet the field has little documentation and analysis of such collaborations. In this article, we present case studies of three research-practice partnerships taking place between scientists and educators. By comparing and contrasting these three partnerships we expect to illuminate common characteristics, challenges, and benefits that come with doing MBE work.

2011-01-01

247

Campylobacter jejuni Fatty Acid Synthase II: Structural and functional analysis of ?-hydroxyacyl-ACP dehydratase (FabZ)  

UK PubMed Central (United Kingdom)

Fatty acid biosynthesis is crucial for all living cells. In contrast to higher organisms, bacteria use a type II fatty acid synthase (FAS II) composed of a series of individual proteins, making...Full Text Available

2009-03-06

248

Big is beautiful in biotechnology  

Energy Technology Data Exchange (ETDEWEB)

Venture capital has guaranteed the successful launch of biotechnology in the US since 1977. Established companies are then licensed to produce and distribute the latest inventions. By contrast in Japan established industrial companies are the leaders in biotechnology research, development and commercialization, building on existing technology and past experience and retraining staff. In the US electronics industry the acute shortage of electronic engineers combined with the high cost of capital and instability within venture capital companies to restrict the high level of innovation required looks likely to happen again in biotechnology.

1984-01-01

249

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

250

Adiabatic theory of Wannier threshold laws and ionization cross sections  

Energy Technology Data Exchange (ETDEWEB)

The Wannier threshold law for three-particle fragmentation is reviewed. By integrating the Schroedinger equation along a path where the reaction coordinate R is complex, anharmonic corrections to the simple power law are obtained. These corrections are found to be non-analytic in the energy E, in contrast to the expected analytic dependence upon E.

1994-12-31

251

A predictive integrated voltage regulator and power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

An integrated voltage regulator and power system stabilizer based on one step ahead prediction is presented. The fixed parameter predictive control scheme is shown capable of providing consistently good voltage response and contribution to system damping over a wide range of operating conditions and system configuration. This is in contrast to the case with conventional automatic voltage regulator and power system stabilizer where performance varies widely with the operating situation and can even cause system instability. (author)

1995-04-01

252

A non-toxic ligand for voxel-based MRI analysis of plaques in AD transgenic mice  

UK PubMed Central (United Kingdom)

Amyloid plaques are a characteristic feature in Alzheimer’s disease (AD). A novel non-toxic contrast agent is presented, Gd-DTPA-K6Aβ1–30, which is homologous to Aβ,...Full Text Available

2008-06-01

253

#sigma#_e_e_#gamma#_#gamma#"t"o"t at e"+e"- colliders  

International Nuclear Information System (INIS)

In this talk I briefly summarize different models for #sigma#_2_#gamma#"t"o"t (e"+e"-#->##gamma##gamma##->#hadrons) and contrast model predictions with the data. I will then discuss the capability of the future e"+e"- and #gamma##gamma# colliders to distinguish between various models and end with an outlook for future work.

2001-07-09

254

The similarity of twin brains; Die Aehnlichkeit von Zwillingsgehirnen  

Energy Technology Data Exchange (ETDEWEB)

To test the assumption underlying every morphometric twin study that the brains of monozygotic twins are almost identical. Methods: High resolution MRI of the neurocranium of 26 monozygotic twin pairs were acquired and the volumes of 36 cerebral structures were measured. The same twins served as control group after rear-ranging them into non-related pairs of same sex and matching them for age, body height and body weight. Results: For most of the examined structures the correlations within the twins were significant (R = 0,97-0,59). Except for total forebrain volume the controls showed no significant similarity. Conclusions: For almost every measured cerebral structure the assumption, that significant similarities exist between healthy monozygotic twins is correct. Therefore discordant monozygotic twins represent an excellent sample when investigating cerebral correlates of neurologic and psychiatric disorders. (orig.) [German] Pruefung der Grundannahme hirnmorphologischer ...

2001-06-01

255

Transforming growth factor-b induces nerve growth factor expression in pancreatic stellate cells by activation of the ALK-5 pathway  

British Library Electronic Table of Contents (United Kingdom)

Nerve growth factor (NGF), a survival factor for neurons enforces pain by sensitizing nociceptors. Also in the pancreas, NGF was associated with pain and it can stimulate the proliferation of pancreatic cancer cells. Hepatic stellate cells (HSC) respond to NGF with apoptosis. Transforming growth factor (TGF)-b, one of the strongest pro-fibrogenic activators of pancreatic stellate cells (PSC) induced NGF and its two receptors in an immortalized human cell line (ihPSC) and primary rat PSC (prPSC) as determined by RT-PCR, western blot, and immunofluorescence. In contrast to HSC, PSC expressed both NGF receptors, although p75NTR expression was weak in prPSC. In contrast to ihPSC TGF-b activated both Smad signaling cascades in prPSC. NGF secretion was diminished by the activin-like kinase (ALK)...

2009-01-01

256

Tissue perfusion measurements: multiple-exposure laser speckle analysis generates laser Doppler-like spectra  

Science.gov (United States)

Variations in skin perfusion are easily detected by laser speckle contrast maps, but a robust interpretation of the information has been lacking. We show that multiple-exposure laser speckle methods produce the same spectral information as laser Doppler methods when applied to targets with embedded moving scatterers. This enables laser speckle measurements to be interpreted more quantitatively. We do this by using computer simulation of speckle data, and by experimental measurements on Brownian motion and skin perfusion using a laser Doppler system and a multiple-exposure laser speckle system. The power spectral density measurements of the light fluctuations derived using both techniques are exactly equivalent. Dermal perfusion can therefore be measured by laser Doppler or laser speckle contrast methods. In particular, multiexposure laser speckle can be rapidly processed to generate a full-field map of the perfusion index proportional to the ...

2010-03-01

257

The diagnostic value of MRI and gadolinium-DTPA compared with CT for the diagnosis of bladder tumours  

International Nuclear Information System (INIS)

In a prospective study, 58 patients with carcinomas of the bladder were examined by CT and MRI; in 48, gadolinium-DTPA was administered intravenously. MRI provided exact staging in 89%, compared with 80% with CT. There was 13% over-staging with CT and 11% with MRI. MRI, unlike CT did not result in any under-staging. In 36 patients a quotient could be calculated from the signal intensity of the tumour and surrounding soft tissues both before and after the intravenous contrast medium and the increased quotient after contrast administration could be estimated. There was a significant increase in the tumour/muscle quotient with a mean of 72#+-#22% (minimum 43%, maximum 153%), corresponding to a marked increase of the signal form the tumour when compared with the precontrast images. This had the following advantages compared with CT: Accurate differentiation between superficial and intramural spread. MRI was better than CT at demonstrating tumours ...

258

Study on the time-domain electromagnetic responses; TDEM ho ni okeru denji oto ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

With an objective to perform three-dimensional analysis with high accuracy in using the electromagnetic exploration method, characteristics in electromagnetic response were analyzed, and conditions for acquiring necessary data were discussed. The discussion defined a parameter called `response anomaly` which uses response from media to standardize response only from substances with abnormal resistivity. The receivers were located uniformly on the same plane, and the response anomaly was derived from electromagnetic response from each of the three horizontal and vertical components at each receiving point, which was expressed as a contour map. The parameter for the abnormal body was consisted of location and resistivity contrast with media. Discussions using the contour map were given on the response when these factors for the parameter were varied. As a result, it was found that the response anomaly appears in the form that reflects the abnormal body, and the ...

1997-05-27

259

Rapid Responding Palladium-Silver Surface Modified Microsensor for Hydrogen  

Science.gov (United States)

Most palladium thin film based hydrogen gas sensors have response and recovery times that are too long to make them useful in vehicular and stationary gas leak detection applications. In contrast, a palladium-silver thin film based microcantilever (MC) hydrogen gas microsensor is reported herein with near ideal response characteristics for use in these hydrogen economy related applications. Specifically, 3-10 second response and recovery times have been measured for these sensors in contrast to previous sensor response measurements of several to tens of minutes using Pd thin film and MC based sensing techniques. The much reduced response times observed in the present study are attributed to a wet chemical Pd-Ag thin film deposition technique and a gas conditioning protocol that produces a highly nanostructured, porous film that rapidly adsorbs and desorbs H2, allowing rapid equilibration with the H2 concentration in the surrounding air. The wet ...

2010-01-01

260

Performance characterization of a volumetric breast ultrasound scanner  

Science.gov (United States)

The purpose of this project was to design, build, and characterize the performance of a volume breast ultrasound (VBUS) scanner that images the pendant breast. VBUS scanner design includes a: 1) clinical ultrasound scanner and transducer; 2) scanning table with a hole for the pendant breast; 3) rotational gantry; 4) probe mounting assembly; 5) compressionless breast stabilization device; 6) acquisition, control, reconstruction, and display software. Performance assessment characterized a variety of parameters including: spatial resolution, uniformity, and distortion using high and low contrast test objects in both horizontal and vertical scanning modes. The VBUS scanner modules have been constructed and initial performance evaluated. Approximately 300 scans are acquired over 360 degrees in 18 seconds. Reconstruction requires 25 ms per slice. Test object images depicted hyper- and hypo-echoic masses and demonstrated good resolution, soft tissue ...

2007-03-01

261

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...

2008-06-01

262

Modern imaging methods for diagnostic evaluation of tumors of the oropharynx and the oral cavity  

International Nuclear Information System (INIS)

Differentiating a benign from a malignant lesion by information such as density data, or signal intensities or echo gradients, is not possible with CT, nor MRI, nor ultrasonography. Only some lesions show characteristic signs. Inflammations cannot be difscriminated from malignant tumors. CTs of small tumors in particular are so poor in contrast that it is much more difficult to detect tumors or discriminate them from other lesions, as compared to MR images or ultrasonographs. CT does not detect surface tumors, but is more sensitive than MRI or US in detecting discrete cortical bone lesions. The same applies to small calcified tumors. MRI however is most sensitive in detecting tumor volumes in the yellow marrow, and is the best modality for evaluation of extraossal extension of tumors. CT yields better results than MRI if applied for simultaneous screening of lymph node metastases in the lower neck. MRI frequently is spoilt by movement artefacts. High-resolution, ...

263

Microstructural transformations and kinetics of high-temperature heterogeneous gasless reactions by high-speed x-ray phase-contrast imaging  

Science.gov (United States)

Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 {mu}s exposure and spatial resolution of 10 {mu}m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of nucleated melting and other ...

2009-12-01

264

Microstructural transformations and kinetics of high-temperature heterogeneous gasless reactions by high-speed x-ray phase-contrast imaging  

International Nuclear Information System (INIS)

Heterogeneous gasless reactive systems, including high-energy density metal-nonmetal compositions, have seen increasing study due to their various applications. However, owing to their high reaction temperature, short reaction time, and small scale of heterogeneity, investigation of their reaction mechanisms and kinetics is very difficult. In this study, microstructural changes and the kinetics of product layer growth in the W-Si system was investigated using a high-speed x-ray phase-contrast imaging technique. Using the Advanced Photon Source of Argonne National Laboratory, this method allowed direct imaging of irreversible reactions in the W-Si reactive system at frame rates up to 36 000 frames per second with 4 #mu#s exposure and spatial resolution of 10 #mu#m. Details of the Si melt and reactions between W and Si, that are unable to be viewed with visible-light imaging, were revealed. These include processes such as the initiation of nucleated melting and other ...

2009-12-01

265

MRI in pleural diseases  

International Nuclear Information System (INIS)

The MRI and CT appearances in 48 patients with histologically confirmed benign and malignant pleural abnormalities were compared retrospectively. Abnormal pleural changes were shown in 47 out of the 48 patients by high signal intensity of the pleura in T_2-weighted sequences and in contrast enhanced T_1-weighted sequences on MRI. CT showed abnormalities in 45 out of 48 patients. Delineation of pleural and pulmonary changes by CT was possible in 13 out of 23 cases, and pleural disease from effusions in 15 out of 28 cases. T_2-weighted MRI was successful in 14 out of 23 and 4 out of 28 cases, respectively. T_1-weighted images after contrast were successful in 20 out of 23 and 22 out of 28 cases, respectively. Indications of malignant pleural disease were the presence of mediastinal or circumferential involvement or involvement of the entire pleura, thickness of more than 10 mm and nodular changes. The most reliable sign of malignancy was ...

266

Injection-associated pain in femoral arteriography: A European multicenter study comparing safety, tolerability, and efficacy of iodixanol and iopromide  

International Nuclear Information System (INIS)

Purpose. To evaluate injection-associated pain, safety, and efficacy with the isotonic contrast medium iodixanol (Visipaque 270 mg I/ml) compared with iopromide (Ultravist 300 mg I/ml) in femoral arteriography. Methods. A multicenter, double-blind, randomized, parallel-group clinical investigation was carried out in 54 hospitals in Europe. Of the patients evaluated, 1225 received iodixanol and 1227 iopromide in conventional and/or digital subtraction angiography. Results. The iodixanol group reported statistically significantly less injection-associated pain (0.9%) than the iopromide group (9.5%) (p<0.001). Further, 4.1% in the iodixanol group experienced pain and/or severe heat sensation vs 19.8% in the iopromide group (p<0.001). In the iodixanol group, 1.8% of the patients experienced contrast-related adverse events vs 2.4% in the iopromide group (p=NS). Overall diagnostic information was optimal for 94.1% in the iodixanol group and ...

1997-07-01

267

Improving crop yield and N uptake with long-term straw retention in two contrasting soil types  

British Library Electronic Table of Contents (United Kingdom)

Retention and/or reincorporation of plant residues increases soil organic nitrogen (N) levels over the long-term is associated with increased crop yields. There is still uncertainty, however, about the interaction between crop residue (straw) retention and N fertilizer rates and sources. The objective of the study was to assess the influence of straw management (straw removed [SRem] and straw retained [SRet]), N fertilizer rate (0, 25, 50 and 75kgNha^-^1) and N source (urea and polymer-coated urea [called ESN]) under conventional tillage on seed yield, straw yield, total N uptake in seed+straw and N balance sheet. Field experiments with barley monoculture (1983-1996), and wheat/barley-canola-triticale-pea rotation (1997-2009) were conducted on two contrasting soil types (Gray Luvisol [Typi...

2011-01-01

268

Grating-based X-ray phase imaging using multiline X-ray source  

International Nuclear Information System (INIS)

Differential phase-contrast X-ray imaging has been performed in a Talbot-Lau configuration, where a multiline X-ray source was used instead of a combination of a hard-X-ray multiple slit and a normal focus X-ray generator. When the multiple slit is used, a high aspect ratio structure is needed and slit width should be below 10 ?m for its function. The fabrication and use of such a multislit can be omitted using the presented configuration. The multiline X-ray source was developed by making grooves on a tungsten rotating anode, which was irradiated by an electron beam to generate X-rays. An array of 10?m line sources with a pitch of 30?m was formed and combined with a 4.5 ?m pitch phase grating and a 5.3 ?m pitch amplitude grating to generate differential phase contrast. With a total exposure time of 40 s, a differential phase image depicting cartilages was obtained. (author)

2009-07-01

269

Functional MRI of the visual cortex and visual testing in patients with previous optic neuritis.  

DEFF Research Database (Denmark)

The volume of cortical activation as detected by functional magnetic resonance imaging (fMRI) in the visual cortex has previously been shown to be reduced following optic neuritis (ON). In order to understand the cause of this change, we studied the cortical activation, both the size of the activated area and the signal change following ON, and compared the results with results of neuroophthalmological testing. We studied nine patients with previous acute ON and 10 healthy persons served as controls using fMRI with visual stimulation. In addition to a reduced activated volume, patients showed a reduced blood oxygenation level dependent (BOLD) signal increase and a greater asymmetry in the visual cortex, compared with controls. The volume of visual cortical activation was significantly correlated to the result of the contrast sensitivity test. The BOLD signal increase correlated significantly to both the results of the contrast sensitivity test ...

2002-01-01

270

Fluid flow visualization with neutron radiography. [Using collimated beam of neutrons  

Energy Technology Data Exchange (ETDEWEB)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...

1991-01-01

271

Fluid flow visualization with neutron radiography  

International Nuclear Information System (INIS)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging techniques such as real-time video, high speed video, and ...

1764-01-01

272

Dura thickening adjacent to intracranial tumors on MRI. Histologically correlation  

International Nuclear Information System (INIS)

Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T_2-weighted spin echo (SE) images as well as T_1-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base also ...

273

Diagnosis of breast cancer with MR imaging using the magnetization transfer contrast and a newly-developed breast surface coil for the supine position  

Energy Technology Data Exchange (ETDEWEB)

We developed a new breast surface coil for the supine position. The subjects consisted of 9 patients with breast cancer varying from 46 to 60 years of age (average: 52). The cancer image of the SPGR (CE+) method was compared with that of the FSMTC (MTC-SPGR (CE+)) method and that of the FSMTC (MTC-SPGR with fat-saturation (CE+)) method in the sagittal section after injection of Gd-DTPA (0.1 mmol/kg). Quantitative analyses were performed before and after injection of Gd-DTPA in 6 patients. Three patients were excluded from the quantitative analyses owing to the clear detection of tumors in the fat tissue. Signal intensity measurements were systematically performed in each region of interest (ROI), i.e. the cancer lesion, the surrounding mammary gland. Statistical analyses showed significant differences between the lesions using the FSMTC (MTC-SPGR (CE+)), and the FSMTC (MTC-SPGR with fat-saturation (CE+)) methods and the lesions using the SPGR (CE+) method after injection of ...

1998-09-01

274

Diagnosis for the cancer extension of cholangiocarcinoma. The current status  

International Nuclear Information System (INIS)

Described is the diagnosis for the cancer extension of cholangiocarcinoma by various imaging techniques and processes to support the current surgical procedure based on preoperative biliary drainage. The cancer tends to locally extend horizontally and/or vertically and its diagnosis is important for surgical indication. For the indication, multi-detector raw CT (MDCT) and MR cholangio-pancreatography (MRCP) are useful and particularly, the former can give multi-phase (arterial, portal and delayed) images to reconstruct multiplanar (MPR) and CT angiographic 3D images, which have made the previous invasive examinations like angiography and percutaneous transportal contrasting unnecessary. MDCT and MRCP can almost complete the diagnosis of the extension. The operative procedure is decided dependently on the site of the lesion, and of which diagnosis, whether it is hepatic hilar/on upper bile duct or middle/lower ductal, is different. MDCT-MPR and MRCP are virtually ...

2010-07-01

275

Computed tomography (CT) in renal trauma  

International Nuclear Information System (INIS)

CT scans were performed on 25 patients suspected of sustaining ranal trauma. The utility of CT in both detecting renal damage and appraising the gravity of injuries was assessed. Nowadays, in fact, nephrectomy or reserved for lesions devastanting the kidney parenchyma or rupturing the renal pedicle; so it is very important to identyfy both the purposes of a better planned therapeutic approach. CT does both, being more accurate than urography in the detection of renal fractures, intra or extraparenchymal hematomas and contrast media extravasation. Urography very often shows aspecific lesion patterns and sometimes it is also falsely negative. In the present series CT was more reliable than angiography itself, particulary in the diagnosis of extra-renal hematic collections, contrast media extravasation and injuries to the other abdominal organs. Although CT may arouse the suspicion of and sometimes correctly diagnose vascular lesions, such as ...

1987-01-01

276

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

277

Assessment of the effects of pixel loss on image quality in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, ...

2004-03-21

278

Assessment of the effects of pixel loss on image quality in direct digital radiography  

International Nuclear Information System (INIS)

Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to pixel loss. Measurement of the MTF, NPS and DQE can reveal small changes ...

2004-03-21

279

A computer-assisted method for 3D subtraction angiography based on spiral CT  

International Nuclear Information System (INIS)

The objective of this study was to develop a method for 3D subtraction CT angiography and to optimize the visualization after semiautomatic segmentation. Ten patients with aneurysms of the abdominal aorta were examined using spiral CT. To reconstruct the vessels, as well as adjacent organs such as the liver and kidneys, one image data volume was acquired before and after injection of the contrast agent. The CT scans were obtained with a Siemens Somatom Plus 4. To improve the results of automatic segmentation, as well as visualization by maximum intensity projection (i.e. removal of bony structures), subtraction of both image volumes is necessary. However, small translation shifts disturb the subtraction process and produce artificial contours. To calculate the disparities along the three coordinate axes of two corresponding image volumes, a cepstrum filter is applied to a pair of image volumes. After detection of the disparities, which manifest as bright spots, the ...

280

Zero-motion flucton correlations in high-energy proton elastic scattering on /sup 40/C  

Energy Technology Data Exchange (ETDEWEB)

The 1.04 GeV-proton elastic scattering from /sup 40/Ca is studied in the framework of the coherent density fluctuation model (CDFM). The calculations are carried out in the Glauber theoretical scheme with three different charge densities. It is shown that: i) the account of the flucton correlations leads to results considerably different from those obtained in the independent particle Glauber approach (IPGA); ii) in contrast to the case of IPGA the use of a more realistic density improves the agreement of CDPM-results with the experimental data.

1985-03-01

281

Zero-motion flucton correlations in high-energy proton elastic scattering on "4"0C  

International Nuclear Information System (INIS)

The 1.04 GeV-proton elastic scattering from "4"0Ca is studied in the framework of the coherent density fluctuation model (CDFM). The calculations are carried out in the Glauber theoretical scheme with three different charge densities. It is shown that: i) the account of the flucton correlations leads to results considerably different from those obtained in the independent particle Glauber approach (IPGA); ii) in contrast to the case of IPGA the use of a more realistic density improves the agreement of CDPM-results with the experimental data. (orig.).

282

YM on the dielectric brane: a D0-brane tale  

Energy Technology Data Exchange (ETDEWEB)

In this letter we present a derivation, from the D0-brane picture, of the background monopole field and in general of the full dynamics of the Yang-Mills theory on the dielectric D2-brane of Myers. To do this we study the large N limit of the fuzzy sphere relevant to the dielectric solution. In contrast to the usual interpretation where the commutative D2-brane picture arises directly from the large N limit of the D0-brane picture, we find that a residual non-commutativity must be preserved in order to make the connection by means of the Seiberg-Witten map.

2003-08-25

283

Understanding the Conundrum of Rebirth Experience of the Beaver, Gitxsan, and Witsuwit'en  

British Library Electronic Table of Contents (United Kingdom)

Summary The First Nations people of British Columbia experience reincarnation as a revitalization of their culture. This article documents the perseverance of reincarnation experiences among the Beaver, Witsuwit'en, and Gitxsan peoples of British Columbia, as well as my own growth in understanding such experiences. It recounts examples of rebirth cases. It explains what rebirth experiences mean to the First Nations people. It describes how these experiences are embedded in their perception of this world and embodied in their beliefs of spiritual realms, which include the interconnected and parallel worlds of fish and land animals, on this world and in spiritual dimensions. While the rebirth worldview contrasts with that of the Western scientific world, this is a worldview I have come to en...

2010-01-01

284

Towards a Model of Understanding Social Search  

CERN Document Server

Search engine researchers typically depict search as the solitary activity of an individual searcher. In contrast, results from our critical-incident survey of 150 users on Amazon's Mechanical Turk service suggest that social interactions play an important role throughout the search process. Our main contribution is that we have integrated models from previous work in sensemaking and information seeking behavior to present a canonical social model of user activities before, during, and after search, suggesting where in the search process even implicitly shared information may be valuable to individual searchers.

2009-01-01

285

Toughened semicrystalline engineering polymers: Morphology, impact resistance, and fracture mechanisms  

Energy Technology Data Exchange (ETDEWEB)

Major factors that contribute to maximized impact resistance of semicrystalline engineering polymers include increased matrix molecular weight, minimal rubber glass-transition temperature, and optimal rubber-particle size, which depends on matrix type. Additional constraints are posed by the limitations of available materials and commercial requirements. Expanding the understanding of impact-modified crystalline engineering polymers will further extend their property ranges and utility. This chapter describes the phenomenology of certain factors, illustrates a new technique to measure rubber particle size, and contrasts the fracture mechanisms of poly(butylene terephthalate), nylon 66, and polyacetal. 49 refs., 24 figs.

1993-12-31

286

The regional control of the canadian energy production; Le contraste provincial de la production energetique canadienne  

Energy Technology Data Exchange (ETDEWEB)

This document provides information and presents data on the energy situation in many regions of Canada. The first part deals with the petroleum and the bitumen shales of Alberta (reserves, exploitation and production, environmental impacts), the second part discusses with the hydroelectricity choice of Quebec and the 2004 crisis. The nuclear situation of Ontario is presented in the third part (nuclear park, programs, uranium reserves, research and development on Candu reactors), while the fourth part deals with the renewable energies (wind power and biomass). The canadian situation facing the Kyoto protocol is discussed in the last part. (A.L.B.)

2004-12-01

287

The effect of oxide inclusions on the kinetics of the austenite to ferrite transformation in low alloy steel weld metal  

Energy Technology Data Exchange (ETDEWEB)

Isothermal transformation kinetics of austenite to acicular ferrite and allotriomorphic ferrite were measured in reheated low alloy steel weld deposits with similar weld compositions and austenite grain size but different inclusion characteristics. Accelerated kinetics of transformation to acicular ferrite were observed in weld metal containing coarser and titanium-rich inclusions. In contrast, kinetics of transformation to allotriomorphic ferrite were not influenced by inclusion characteristics, but, rather, by the austenite grain size and carbon concentration.

1994-09-01

288

The behavior of bonded doubler splices for composite sandwich panels  

Science.gov (United States)

The results of an investigation into the behavior of adhesively bonded doubler splices of two composite material sandwich panels are presented. The splices are studied from three approaches: analytical; numerical (finite elements); and experimental. Several parameters that characterize the splice are developed to determine their influence upon joint strength. These parameters are: doubler overlap length; core stiffness; laminate bending stiffness; the size of the gap between the spliced sandwich panels; and room and elevated temperatures. Similarities and contrasts between these splices and the physically similar single and double lap joints are discussed. The results of this investigation suggest several possible approaches to improving the strength of the sandwich splices.

1980-07-01

289

Ten-nanometer surface intrusions in room temperature silicon  

CERN Document Server

Defects ~10 nm in size, with number densities ~10^{10} cm^{-2}, form spontaneously beneath ion-milled, etched, or HF-dipped silicon surfaces examined in our Ti-ion getter-pumped transmission electron microscope (TEM) after exposure to air. They appear as weakly-strained non-crystalline intrusions into silicon bulk, that show up best in the TEM under conditions of strong edge or bend contrast. If ambient air exposure is <10 minutes, defect nucleation and growth can be monitored {\\em in situ}. Possible mechanisms of formation are discussed.

2002-01-01

290

Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines  

Energy Technology Data Exchange (ETDEWEB)

Four /sup 125/I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported /sup 75/Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).

1982-07-01

291

Synovial cysts of the lumbar spine: CT and MRI correlations  

Energy Technology Data Exchange (ETDEWEB)

Intraspinal synovial cysts were diagnosed in six patients during a 5-year period and retrospectively studied. Plain films of the lumbar spine showed degenerative changes in all patients. Lumbar myelography showed a posterior and lateral defect caused by extradural compression. Using CT without contrast enhancement established the diagnosis in five of the six patients. In four cases MRI was performed, three before and after injection of gadolinium diethyline-triamine penta-acetic acid (Gd-DTPA). Including the patient with a false-negative CT, MRI was positive in all patients. (orig.)

1994-08-01

292

Static potential of open bosonic membranes  

Energy Technology Data Exchange (ETDEWEB)

We study the static potential of open bosonic membranes in the 1/d approximation, where d is the space-time dimensionality. For a fixed square boundary of side length R we find, in contrast to the string potential, no critical distance below which tachyons appear. Instead, we find a correction factor to the classical potential, V/sub cl/=kR/sup 2/, which for small distances shifts the perturbative ground state energy by a positive constant. We interpret the shift as the mass gap of this quantum membrane.

1989-03-30

293

Similarity between the primary and secondary air-assisted liquid jet breakup mechanism  

CERN Document Server

we report an ultrafast synchrotron x-ray phase contrast imaging study of the primary breakup mechanism of a coaxial air-assisted water jet. We demonstrate that there exist great similarities in the phenomenology of primary breakup with that of the secondary breakup. Especially, a membrane-mediated breakup mechanism dominates the breakup process for a wide range of air speeds. This finding reveals the intrinsic connections of these two breakup regimes and has deep implications on the unified theoretical approach in treating the breakup mechanism of high speed liquid jet.

2007-01-01

294

Resonance scattering of Lyman-. cap alpha. radiation by hydrogen in the ground state  

Energy Technology Data Exchange (ETDEWEB)

We calculate the cross section for the resonance scattering of Lyman-..cap alpha.. radiation by spinless nonrelativistic hydrogen atoms in the ground state using a two-level model. A generalization of Dirac's resonance scattering theory is used together with the exact matrix elements for the electromagnetic interaction. In contrast to the usual treatments in which only the dipole approximation for the matrix elements are taken, the shift in position of the resonance is finite and has a value of 75% of the Lamb shift of the n=1 state. Whether this latter fact is significant in renormalization calculations is left open.

1980-11-01

295

RADSOLVER: a computer program for calculating spectrally-dependent radiative heat transfer in solar cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

RADSOLVER is a computer program which calculates the radiation energy transport in cavity type receivers having an arbitrary number of apertures through which collimated beams of solar radiation enter. In contrast to the common assumption of gray (or semi-gray) surfaces used in the modeling of radiation transport, RADSOLVER accounts for the wavelength-dependence of emission, absorption and reflection with a band model of the radiative properties. It is intended that this report serve both as an instruction manual for the use of the RADSOLVER code and a vehicle for presenting the underlying theory. Illustrative examples along with input and output are presented.

1981-09-01

296

Precipitation, phase transformation, and enhanced diffusion in ion-implanted silicon  

International Nuclear Information System (INIS)

This paper describes Z-contrast scanning transmission electron microscopy used to study the connection between dopant precipitation and phase transformation in high dose In"+ and Sb"+ implanted Si. In the case of In, the observations confirm a heterogeneous nucleation model. Images of the precursor precipitates give the first measurement of the diffusion coefficient in amorphous Si, with an enhancement of 10"7 over tracer crystalline values. With Sb"+ implants enhanced homogeneous nucleation is observed. The connection between these results and the transient enhanced diffusion observed in crystallized Si is discussed.

297

Plasmid-conferred tetracycline resistance confers collateral cadmium sensitivity to E. coli cells  

Energy Technology Data Exchange (ETDEWEB)

E. coli HB101 cells transformed to tetracycline resistance with the plasmids pMB9 or pBR322 display a 10/sup 5/-10/sup 6/-fold lower plating efficiency on agar containing 440 ..mu..M CdCl/sub 2/ than nontransformed cells. When DNA is inserted into the BamH1 site of the plasmid tet gene, or when DNA spanning the BamH1 site is deleted, tetracycline resistance and cadmium hypersensitivity are both lost. In contrast, insertion of DNA into the ampicillin resistance gene does not affect cadmium hypersensitivity.

1982-01-01

298

Phenomenological dirac optical potential for neutron cross sections  

International Nuclear Information System (INIS)

Because of limitation on neutron-incident data, it is difficult to obtain global optical model potential for neutrons. In contrast, there are some global optical model potentials for proton in detail. It is interesting to convert the proton-incident global optical potentials into neutron-incident ones. In this study we introduce (N-Z)/A dependent symmetry potential terms into the global proton-incident optical potentials, and then obtain neutron-incident ones. The neutron potentials reproduce total cross sections in an acceptable degree. However, a comparison with potentials proposed by other authors brings about a confused situation in the sign of the symmetry terms. (author).

1997-03-01

299

On Financial Markets Based on Telegraph Processes  

CERN Document Server

The paper develops a new class of financial market models. These models are based on generalized telegraph processes: Markov random flows with alternating velocities and jumps occurring when the velocities are switching. While such markets may admit an arbitrage opportunity, the model under consideration is arbitrage-free and complete if directions of jumps in stock prices are in a certain correspondence with their velocity and interest rate behaviour. An analog of the Black-Scholes fundamental differential equation is derived, but, in contrast with the Black-Scholes model, this equation is hyperbolic. Explicit formulas for prices of European options are obtained using perfect and quantile hedging.

2007-01-01

300

Nucleon and meson effective masses in the relativistic mean-field theory  

Energy Technology Data Exchange (ETDEWEB)

Nucleon and meson effective masses in the nonlinear relativistic mean-field theory introducing a nonlinear {omega}-{rho} and {sigma} coupling motivated by the quark-meson coupling model is explored. It is shown that, in contrast to the usual Walecka model, not only the effective nucleon mass m{sub eff,N} but also the effective {sigma},{rho} meson masses (m{sub eff{sigma}},m{sub eff,{rho}}) and the effective {omega} meson mass m{sub eff,{omega}} are nucleon density dependent. (author)

2001-10-01

301

Nucleon and meson effective masses in the relativistic mean-field theory  

International Nuclear Information System (INIS)

Nucleon and meson effective masses in the nonlinear relativistic mean-field theory introducing a nonlinear #omega#-#rho# and #sigma# coupling motivated by the quark-meson coupling model is explored. It is shown that, in contrast to the usual Walecka model, not only the effective nucleon mass m_e_f_f_,_N but also the effective #sigma#,#rho# meson masses (m_e_f_f_#sigma#,m_e_f_f_,_#rho#) and the effective #omega# meson mass m_e_f_f_,_#omega# are nucleon density dependent. (author)

2001-10-01

302

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

303

Measurement of low-energy laser pulse duration in femtosecond range  

International Nuclear Information System (INIS)

Measurements of low-energy (#approx#10"- "1"0 J) femtosecond laser pulse durations have been carried out on the basis of second-order autocorrelation function analysis. The scheme of non collinear second harmonic generation realized in KDP crystal has been used for increasing of the measurement contrast and accuracy. Proposed scheme can be used for measurements in wide enough ranges of laser pulse durations (from tens femto seconds to hundreds picoseconds) and energies. (authors)

304

Measurement of Turbulence Decorrelation during Transport Barrier Evolution in a High Temperature Fusion Plasma  

Energy Technology Data Exchange (ETDEWEB)

A low power polychromatic beam of microwaves is used to diagnose the behavior of turbulent fluctuations in the core of the JT-60U tokamak during the evolution of the internal transport barrier. A continuous reduction in the size of turbulent structures is observed concomitant with the reduction of the density scale length during the evolution of the internal transport barrier. The density correlation length decreases to the order of the ion gyroradius, in contrast to the much longer scale lengths observed earlier in the discharge, while the density fluctuation level remain similar to the level before transport barrier formation.

2005-03-29

305

Magnetic response of ultrathin Fe on MgO: A polarized neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

The magnetization of ultrathin bcc Fe films (two and three monolayers) on MgO was measured and compared with the behavior predicted for a two-dimensional ferromagnet. The experiment indicated that no hysteresis was present in the magnetization. Instead, the magnetization at low temperature was affected by a marked field cooling effect. These observations lead to the conclusion that films of Fe on MgO of such thickness exhibit superparamagnetic behavior as if they were not entirely continuous. In contrast, films thicker than five monolayers exhibit a magnetic response close to that of bulk iron.

1994-11-15

306

Magnetic fluctuation measurement in Sino United Spherical Tokamak plasma  

International Nuclear Information System (INIS)

To investigate the magnetic fluctuations and for further transport study, the poloidal and radial magnetic field measurement is conducted on the Sino United Spherical Tokamak (SUNIST). Auto-power spectral density indicates that the magnetic fluctuation energy mainly concentrates in the frequency region lower than 10 kHz. The magnetic field oscillations, which are characterized by harmonic frequencies of 40 kHz, are observed in the scrape-off layer; by contrast, in the plasma core, the magnetic fluctuations are of Gaussian type. The time-frequency profiles show that the poloidal magnetic fluctuations are temporally intermittent. The autocorrelation calculation indicates that the fluctuations in decorrelation time vary between the core and the edge. (authors)

2007-07-01

307

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

308

Long-term monitoring of microleakage of dental cements by radiochemical diffusion  

International Nuclear Information System (INIS)

Radioactive "1"4C sucrose was found to be an ideal marker for microleakage because it did not penetrate tooth tissue, dental cement, or mounting resin. The main finding is that the adhesive cements--the glass-ionomer and polycarboxylate--are significantly more effective at preventing microleakage than are the traditional phosphate cements--silicate and zinc phosphate. The differences can be as high as two orders of magnitude. The adhesive cements provide almost perfect and reliable seals. By contrast, the nonadhesive cements are erratic sealants with most of the restorations leaking.

309

Light Scalar Mesons as Manifestation of Spontaneously Broken Chiral Symmetry  

CERN Document Server

Attention is paid to the production mechanisms of light scalars that reveal their nature. We reveal the chiral shielding of the \\sigma(600) meson. We show that the kaon loop mechanism of the \\phi radiative decays, ratified by experiment, points to the four-quark nature of light scalars. We show also that the light scalars are produced in the two photon collisions via four-quark transitions in contrast to the classic P wave tensor q\\bar q mesons that are produced via two-quark transitions $\\gamma\\gamma\\to q\\bar q$. The history of spontaneous breaking of symmetry in quantum physics is discussed in Appendix.

2010-01-01

310

Industrial aspects and literature survey: Combined inventory management and routing  

British Library Electronic Table of Contents (United Kingdom)

This paper describes industrial aspects of combined inventory management and routing in maritime and road-based transportation, and gives a classification and comprehensive literature review of the current state of the research. The literature is contrasted with aspects of industrial applications from a constructive, but critical, viewpoint. Based on the status and trends within the field, future research is suggested with regard to both further development of the research area and industrial needs. By highlighting the industrial aspects, practitioners will hopefully see the benefit of using advanced decision support systems in complex situations related to combined inventory management and routing in their business. In addition, a classification and presentation of the research should hel...

2010-01-01

311

Improved synthesis of (/sup 15/N) 16-Doxyl stearic acid  

Energy Technology Data Exchange (ETDEWEB)

An improved method for the synthesis of (/sup 15/N) 16-Doxyl stearate, a fatty-acid spin label, is reported. The method requires only one mole of (/sup 15/N) 2-amino-2-methyl propanol per mole of methyl keto stearate with an overall yield of about 50%. In contrast, the previous method produced only 1-3% yield. The great improvement in yield was achieved mainly through the reduction of reaction volume which increases the reaction rate by the law of mass action.

1987-10-01

312

Imaging findings of abdominal peripheral primitive neuroectodermal tumor: report of four cases with pathological correlation  

British Library Electronic Table of Contents (United Kingdom)

Peripheral primitive neuroectodermal tumors (peripheral PNETs) are rare in the abdomen. We report the imaging findings of four peripheral PNETs arising in the abdomen. Three were ill-demarcated tumors and one was a well-demarcated tumor, with extensive local invasion and lymph node metastasis in two cases, respectively. The tumors are of inhomogeneous attenuation and heterogeneous enhancement after intravenous administration of contrast materials. Although their imaging manifestations cannot distinguish them from other sarcomas, recognition of these imaging features may be helpful in suggesting the possibility of peripheral PNETs in some cases.

2009-01-01

313

Image analysis of complex microstructures by texture analysis and correlation with properties by neural networks; Bildanalyse komplexer Werkstoffgefuege durch Texturanalyse und Korrelation mit den Eigenschaften durch neuronale Netze  

Energy Technology Data Exchange (ETDEWEB)

By characterising the microstructure, quantitative image analysis allows to draw conclusions on the mechanical properties of materials. On fine microstructures with low contrast, e.g. of hardened steels, texture analysis has to be applied for quantification. Feeding texture parameters according to Haralick into a trained neural network, a correlation between the microstructure and the hardness of the steels C45 and 100Cr6 can be achieved. (orig.)

2001-08-01

314

Idiopathic renal hematuria in a military working dog.  

Science.gov (United States)

A 1.5-year-old male Belgian Malinosis Military Working Dog presented with a 1-month history of intermittent hematuria. Diagnostic ultrasound and contrast radiography demonstrated large blood clots in the urinary bladder and a filling defect in the right renal pelvis. At surgery, clotted blood was present in the right ureter and bladder. Following right nephrectomy, the dog returned to training. One month later, elevations in urea nitrogen and creatinine were noted. Hematuria recurred at 3 months and the dog was found dead in its kennel. Necropsy showed a blood-filled left renal pelvis and ureter. PMID:1454185

1992-10-01

315

IMAGING DIAGNOSIS-SYNOVIAL MYXOMA OF LUMBAR VERTEBRAE ARTICULAR PROCESS JOINT  

British Library Electronic Table of Contents (United Kingdom)

Magnetic resonance (MR) imaging and histopathology were used to diagnose an articular process synovial myxoma in a dog. On MR images, the tumor was characterized by distortion of the left L1-L2 articular process, widening of the articular process joint, and the presence of a mass contiguous with the synovium of the articular process that displaced the spinal cord. The tumor was T2-hyperintense, T1-hypointense, relative to muscle, and had mild contrast enhancement. The MR features of articular process synovial myxoma may be distinct from other diseases of the articular process joint.

2011-01-01

316

High resolution transmission electron microscopy of partial states of oxygen order in YBa_2Cu_3O_z  

International Nuclear Information System (INIS)

This paper reports on high resolution electron microscopy used to investigate the effect of electron irradiation induced oxygen loss on the states of partial order in YBa_2Cu_3O_z. Contrast effects visible in the [001] zone image as a result of the degree of the out-of-plane correlation of these ordered states are investigated. Using statistical simulations to aid in the analysis of the HREM images, an interpretation based on a kinetically limited evolution of the variation of long range [001] ordering is proposed.

1990-04-16

317

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

318

First experiences with application of gadolinium-DTPA in infants and small children under two years of age  

International Nuclear Information System (INIS)

The use of Gadolinium-DTPA as a paramagnetic contrast agent in MRI with adults and juveniles concerning brain and spinal cord pathology is well proven since years. In the FRG it is only introduced for children over two years of age. Therefore this report deales with the experience in four infants and small children under the age of two. They all were suffering from neurological tumors and got additional diagnostic information in three cases. Clinical side-effects like urticaria, vomiting or convulsions had not been observed nor had pathologic changes of the biochemical parameters been noticed. (orig./GDG).

319

Field surgery on a future conventional battlefield: strategy and wound management.  

Science.gov (United States)

Most papers appearing in the surgical literature dealing with wound ballistics concern themselves with wound management in the civilian setting. The pathophysiology of modern war wounds is contrasted with ballistic wounds commonly encountered in peacetime, but it should be noted that even in peacetime the modern terrorist may have access to sophisticated military weaponry, and that patients injured by them may fall within the catchment area of any civilian hospital. Management problems associated with both wound types are highlighted; areas of controversy are discussed. The orthodox military surgical approach to ballistic wounds is expounded and defended. PMID:1996857

1991-01-01

320

Evaluation of the chest radiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

1991-12-01

321

Evaluating the Efficiency of Asynchronous Systems with FASE  

CERN Document Server

In this paper, we present FASE (Faster Asynchronous Systems Evaluation), a tool for evaluating the worst-case efficiency of asynchronous systems. The tool is based on some well-established results in the setting of a timed process algebra (PAFAS: a Process Algebra for Faster Asynchronous Systems). To show the applicability of FASE to concrete meaningful examples, we consider three implementations of a bounded buffer and use FASE to automatically evaluate their worst-case efficiency. We finally contrast our results with previous ones where the efficiency of the same implementations has already been considered.

2011-01-01

322

Diagnosing hepatocellular carcinoma with the intensity and the lifetime of two-photon red autofluorescences  

Science.gov (United States)

We demonstrated that the intensity levels and lifetimes of two-photon autofluorescences (2PAF) in human liver tissues can be exploited to diagnose hepatocellular carcinoma (HCC). Excited by an infrared femtosecond laser, we suppressed the two-photon autofluorescences of most endogenous fluorophores and made red autofluorescences more specific to particular molecules in the cryo-sectioned human livers. Using such fluorescence contrast, we found HCC tissues have reduced levels of 2PAF and longer fluorescence lifetime.

2011-02-01

323

Cosmological models without singularities  

Energy Technology Data Exchange (ETDEWEB)

A previously studied theory of gravitation in flat space-time is applied to homogeneous and isotropic cosmological models. There exist two different classes of models without singularities: (i) ever-expanding models, (ii) oscillating models. The first class contains models with hot big bang. For these models there exist at the beginning of the universe-in contrast to Einstein's theory-very high but finite densities of matter and radiation with a big bang of very short duration. After short time these models pass into the homogeneous and isotropic models of Einstein's theory with spatial curvature equal to zero and cosmological constant ALPHA >= O.

1981-11-01

324

Computed Tomography of the cranio-cervical junction in rhematoid arthritis  

International Nuclear Information System (INIS)

Twenty rheumatoid arthritis (RA) patients with involvement of the cranio-cervical junction (CCJ) were given CT scan. In most cases the myelo-CT technique with the lumbar injection of small quantities of non-ionic contrast medium was adopted; CT easily diagnosed the horizontal and vertical dislocations on the CCJ, the bone strcture lesions and the inflammatory masses. A high frequency of medullary compressions was also found in these patients. Myelo-CT appears to be the technique of choice for the precise definition of the various factors responsible for the neurological complications found in RA of the CCJ.

1987-01-01

325

Coherent correlation enhancement of outer shell photoionization cross sections of alkali-like ions  

Energy Technology Data Exchange (ETDEWEB)

An alkali-like ion interaction with inner electrons of an alkali-like ion leads to a significant increase in the photoionization cross section of the outer s electron. This occurs not only for ground-state ions with one s electron in the outer shell, but also when the outer s electron is in an excited state. The reason for this amplification, in addition to coherent enhancement in summing of the correlation amplitudes, is that the zero in the direct amplitude occurs below threshold. This leads to a constructive interference with the correlation amplitude above the photoionization threshold, in contrast to a destructive interference in the case of a neutral atom with the same electronic configuration, for which the zero occurs above threshold. Results of this research were published.

1995-08-01

326

Brand-specific tastes for quality  

British Library Electronic Table of Contents (United Kingdom)

This paper develops a model of nonlinear pricing with competition. The novel element is that each consumer's willingness to pay for quality is private information and is allowed to differ across brands. The consumer's preferences are represented by a multidimensional type containing the marginal value of quality for different products. Buyers with high willingness to pay for quality also display strong preferences for particular brands, and require higher discounts in order to switch away from their favorite product. Therefore, competition is fiercer for buyers with lower tastes for quality, and hence more elastic demands. This is in sharp contrast to earlier models in which competition is fiercer for higher-taste, more valuable buyers. In equilibrium, firms either compete intensively for ...

2011-01-01

327

Application of relationship marketing and management: a large contractor case study  

British Library Electronic Table of Contents (United Kingdom)

Marketing-led enterprise change management initiated by a major UK contractor is explored in this paper as a contrast to procurement-led changes to projects driven by clients. Procurement-led initiatives try to induce changes to behaviour through market governance. Relationship marketing and management proactively change organizational behaviour, the enterprise taking responsibility for its own destiny. Investment and resource allocation, and organizational behaviour have posed constraints, particularly concerning service continuity in construction. Overcoming these constraints offers opportunities for delivering service improvements and adding value for clients and yielding further increases in repeat business and increasing profitability. Relationship marketing is the conceptual starting...

2009-01-01

328

A measurement of the cross section for electron impact ionization of Ar"2"+, Kr"2"+ and Xe"2"+  

International Nuclear Information System (INIS)

The crossed electron-ion beams technique was used to measure absolute cross sections for single ionization of Ar"2"+, Kr"2"+ and Xe"2"+ ions at electron energies ranging from threshold to 2000 eV. In contrast to some previous measurements, the metastable contents of the ion beams were small even in the case of Xe"2"+. All measured cross section curves show significant contributions from excitation-autoionization and possibly direct ionization of inner-shell electrons. There is evidence for resonance-excitation-double-autoionization in the case of Xe"2"+. (author).

329

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using inverse Compton scattering sources and we ...

2009-09-01

330

Multislice helical CT in the diagnosis of hilar cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To investigate the value ofMSCT in observing the direct findings of hilar cholangiocarcinoma1Methods Multislice helical CT studies were performed on the upper abdomen in 19 consecutive patientswith painless jaundice1 Precontrast and dynamic contrast enhanced (25 s phase and 60 s phase) scanswere conducted, and 3D imageswere reconstructed using enhanced raw data in 15 cases1 The direct CT findings of hilar cholangiocarcinoma were studied by three radiologists respectively in a 32scale strategy1 The morphological features and extension of bile duct involvement by hilar cholangiocarcinoma were analyzed1 All the 19 caseswere pathologically p roved as hilar cholangiocarcinoma by surgery (15 cases) and ERCP ( 4 cases) 1 Results The direct findings and extension of hilar cholangiocarcinoma could be demonstrated in 14 out of 15 3D reconstruction images, 8 out of 19 in 25 s phase, and 7 out of 19 in 60 s phase of contrast enhancement scans, ...

2005-11-01

331

Laser flash effects on chromatic discrimination in monkeys. Final report, April 1986-June 1987  

Energy Technology Data Exchange (ETDEWEB)

Detecting a camouflaged target in a visually noisy background depends on the ability of the observer to discriminate the target from the surrounding terrain. Visible laser irradiation at less than damage levels can act as a masking source by compromising or reducing the observer's ability to resolve differences in the visual scene. Previous research has examined this concept by investigating laser flash effects on: acuity (size discrimination); tracking (motion discrimination); visual sensitivity (color); and contrast sensitivity functions (luminance contrast). In all cases, flashes from continuous-wave (CW) sources have proven more effective visually than pulsed (Q-switched) sources, when compared on peak-energy criteria (i.e., MPE), even though Q-switched lasers induce damage at lower energy doses. Additionally, the inherent safety of ultra-short laser pulses has been questioned. Past animal research has shown that, on the measures ...

1987-10-01

332

Contrast-enhanced helical CT in sigmoid diverticulitis. Findings and impact on diagnosis and treatment; Ruolo della tomografia computerizzata spirale nella diverticolite del sigma e implicazioni diagnostico-terapeutiche  

Energy Technology Data Exchange (ETDEWEB)

Aim of this retrospective study was to assess the capability of contrast-enhanced helical computerised tomography (CT) in sigmoid diverticulitis, especially relative to selection of the appropriate treatment. The findings of 41 patients were reviewed from 1998 to 1999 June. Contrast-enhanced helical CT is the imaging modality of choice in assessing mild or severe acute diverticulitis because it provides useful information for appropriate treatment planning in the emergency setting. This technique is most useful in questionable cases and in patients with suspected severe diverticulitis where a choice must be made between different treatment options. [Italian] Scopo di questo studio retrospettivo e' illustrare i molteplici aspetti radiologici della flogosi diverticolare sigmoidea con tomografia computerizzata (TC) spirale, con specifico riguardo alle implicazioni terapeutiche che scaturiscono dall'analisi e dal confronto dei ...

2000-03-01

333

Contrast material extravasation following upper abdominal trauma. Detection with helical Computerized Tomography; Stravaso del mezzo di contrasto nei traumi dell'addome superiore. Riconoscimento con Tomografia Computerizzata spirale  

Energy Technology Data Exchange (ETDEWEB)

Active contrast material extravasation can be recognized with conventional CT scanners, though it has been considered a rare finding. Helical CT seems to increase the detection rate and especially to boost the radiologist's confidence in this diagnosis. Though active bleeding is defined in severely-injured subjects requiring urgent intervention and may be associated with findings of hypovolaemic shock, it should not be considered itself as a negative prognostic factor. Contrast extravasation is due to ongoing hemorrhage and its detection is critical for urged treatment. Accurate anatomical location permits to choose surgical management or transcatheter embolization and thus decreases time consumption for precis e bleeding site identification. [Italian] Lo stravaso attivo del mdc e' rilevabile anche con appropriate apparecchiature TC tradizionali, sebbene sia stato considerato raro. La TC sprirale sembra aumentare la frequanza ...

1999-03-01

334

Comparison of gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for enhanced MR imaging of brain and spine tumours in children  

International Nuclear Information System (INIS)

Sixty-three subjects, aged 6 months to 16 years, who were enrolled in a prospective, fully blinded, randomized parallel-group phase III clinical trial, received 0.1 mmol/kg doses of either Gd-BOPTA (n=29) or Gd-DTPA (n=34). The MR images were acquired before and within 10 min of contrast agent injection. The primary objective was to compare the difference from pre-dose to post-dose lesion visualization between Gd-BOPTA and Gd-DTPA. Lesion visualization was determined as the sum of individual scores for three criteria of lesion morphological characteristics (lesion border delineation, internal morphology, and contrast enhancement), each assessed qualitatively using 4-point scales. Quantitative evaluation compared changes in lesion-to-background (LBR) and contrast-to-noise (CNR) ratios and per cent enhancement. Monitoring for adverse events and evaluation of vital signs and laboratory values was performed. Pre-dose to ...

2005-05-01

335

Stent placement under real-time MR control: first experience in an animal model; Stentplazierung unter Echtzeit-MR-Kontrolle: erste tierexperimentalle Erfahrungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: The aim of this study was to test the feasibility of iliac artery stent placement under MR guidance with real-time MR radial scanning in an animal model. Materials and methods: The experiments were performed on three pigs in a 1.5 T scanner. Radial scanning with a gradient echo technique (T{sub R} 8.4 ms, T{sub E} 3.6 ms, flip angle 10 ) was used. A dedicated backprojector performed the reconstruction of the raw data in real-time. The resulting MR-images were displayed on LCD screens beside the magnet. The sliding window reconstruction technique allowed image acquistion at a frame rate of 16 images per second. MR-compatible self-expanding stents with a diameter of 8 mm and a length of 3 cm were placed into the left iliac artery. Their positions were verified by digital subtraction angiography (DSA) and compared to MRI. Results: All stents were successfully placed. Stent positions as monitored by real-time MR were identical to those seen on DSA images. The time needed for exact ...

1998-12-01

336

State and development of uterine myoma embolization in Germany; Stand und Entwicklung der Uterusmyomembolisation in Deutschland  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the current situation and implementation of embolization of uterine leiomyomas into the treatment concept in women with symptomatic uterine leiomyomas in Germany. A questionnaire addressing the clinical background of uterine myomas, recommended treatment concepts, preclinical evaluation, technical approach and complications was sent to 164 departments of gynecology and radiology in Germany. 33 radiological departments and 19 gynecological departments submitted a completed questionnaire. Only 7 departments of radiology reported to have own experience with embolization of uterine leiomyomas, while only 2 departments of gynecology considered embolization as an alternative treatment option in patients with symptomatic leiomyomas. 18/33 radiological departments offer this treatment option but get no patient referrals. Agreement was found concerning the indications for treatment, preclinical evaluation by ultrasound and MRI, preferable location of treatable fibroids, technical ...

2003-08-01

337

Transcutaneous oximetry compared to ankle-brachial-index measurement in the evaluation of percutaneous transluminal angioplasty  

International Nuclear Information System (INIS)

Objective: To investigate transcutaneous oximetry as parameter of the microcirculation is correlated to ankle-brachial-index as parameter of the macrocirculation after peripheral angioplasty procedures. Design: Prospective study. Materials and methods: 60 patients suffering from intermittent claudication were scheduled for angioplasty treatment. 45 patients were considered as eligible for angioplasty after angiographic evaluation, 15 patients underwent angiography only. Transcutaneous oximetry measurements were performed before the procedure, at the end of intervention, 24 h as well as 2 and 4 weeks after percutaneous transluminal angioplasty. Ankle-brachial-indices were obtained before intervention, 24 h as well as 2 and 4 weeks later. Results: Ankle-brachial-indices increased significantly at 24 h after angioplasty in patients being treated with angioplasty. Transcutaneous oximetry values dropped significantly at the end of the procedure and returned close to the baseline levels at 2 ...

2007-11-01

338

Role of Spiral and Multislice Computed Tomography in the evaluation of traumatic and spontaneous oesophageal perforation. Our experience  

International Nuclear Information System (INIS)

Purpose: To assess the role of CT in the evaluation of traumatic and spontaneous oesophageal perforation. Materials and methods: From March 2001 to May 2003, we studied 12 patients (7 males and 5 females; age range: 25-66 years, mean age: 43.5 years) with suspected oesophageal perforation due to motor-vehicle accidents (4 cases), stab wound (one case), post-intubation (2 cases), foreign body ingestion (2 cases) and spontaneous (3 cases). Five patients underwent standard chest and cervical radiography; two patients with suspected foreign body ingestion also underwent a gastrografin swallow study; all of the 12 patients underwent CT of the neck, chest and abdomen before and after intravenous, and in four cases oral, administration of contrast material. Results: In 5 patients with cervical, thoracic and abdominal trauma, the CT examination showed the presence of pleuroparenchymal injury (pneumothorax, pleural effusion and subcutaneous emphysema) as well as findings ...

2005-03-01

339

Multiphasic helical CT of hepatocellular carcinoma. Evaluation after chemo embolization  

International Nuclear Information System (INIS)

The main purpose of this work is to report the personal experience with addition of contrast-enhanced multiphase helical CT to unenhanced CT (Lipiodol CT) in the evaluation of patients with hepatocellular carcinoma treated with chemoembolization and to analyze the present role of oily agent CT. It has been retrospectively reviewed the examinations of 42 consecutive patients submitted to globla chemoembolization over a 2-year period. CT was performed 18-30 days after the treatment. The Lipiodol CT study was carried out with volume acquisitions. It has been considered as nodules all well-defined areas with dense oily agent uptake; uptake itself was classified as: 0=absent, I=lower tha 10% of the tumor volume; II=lower than 50%, III=50%, IV=homogeneous. Contrast-enhanced helical CT was performed with the 2-phase technique in 28 patients and with the 3-phase technique in 14; it has been considered as nodules all well-defined and relatively ...

2000-06-01

340

Multi-modality imaging of uveal melanomas using combined PET/CT, high-resolution PET and MR imaging  

Energy Technology Data Exchange (ETDEWEB)

We investigated the efficacy of combined FDG-PET/CT imaging for the diagnosis of small-size uveal melanomas and the feasibility of combining separate, high-resolution (HR) FDG-PET with MRI for its improved localization and detection. Patients, methods: 3 patients with small-size uveal melanomas (0.2-1.5 ml) were imaged on a combined whole-body PET/CT, a HR brain-PET, and a 1.5 T MRI. Static, contrast-enhanced FDG-PET/CT imaging was performed of head and torso with CT contrast enhancement. HR PET imaging was performed in dynamic mode 0-180 min post-injection of FDG. MRI imaging was performed using a high-resolution small-loop-coil placed over the eye in question with T2-3D-TSE and T1-3D-SE with 18 ml Gd-contrast. Patients had their eyes shaded during the scans. Lesion visibility on high-resolution FDGPET images was graded for confidence: 1: none, 2: suggestive, 3: clear. Mean tumour activity was calculated for summed image ...

2008-07-01

341

Aortic non communicating dissections. A study with helical CT  

International Nuclear Information System (INIS)

The evaluate the signs of aortic intramural hematoma with helical CT and the diagnostic role of this technique in patients with this condition. It was reviewed the CT findings of 396 patients submitted to emergency examinations for suspected aortic dissection from 1995 to 1999. Only 18 patients (6 women and 12 men) had CT signs of aortic intramural hematoma. Helical CT studies were carried out with the following parameters: slice thickness 10 mm, reconstruction index 10, feed 1.5 mm, conventional algorithm with minimum values of 130 kV and 125mA. All patients were examined with dynamic contrast-enhanced CT, before and after a power injection of 130 mL ionic contrast material. It was studied: hematoma localization and longitudinal extension; thickness and density of aortic wall; presence and location of intimal calcifications; integrity of intimal wall; hemo mediastinum and/or hemo thorax. Aortic wall thickening appeared as a high density ...

2000-09-01

342

np{yields}d{gamma} for big-bang nucleosynthesis  

Energy Technology Data Exchange (ETDEWEB)

The cross section for np{yields}d{gamma} is calculated at energies relevant to big-bang nucleosynthesis using the recently developed effective field theory that describes the two-nucleon sector. The E1 amplitude is computed up to N{sup 3}LO and depends only upon nucleon-nucleon phase shift data. In contrast, the M1 contribution is computed up to next-to-leading order, and the four-nucleon-one-magnetic-photon counterterm that enters is determined by the cross section for cold neutron capture. The uncertainty in the calculation for nucleon energies up to E{approx}1 MeV is estimated to be (less-or-similar sign)4%. (c) 1999 The American Physical Society.

1999-12-01

343

Zero-motion correlations in high-energy proton elastic scattering on sup 40 Ca with noneikonal nucleon-nucleon amplitude  

Energy Technology Data Exchange (ETDEWEB)

Using a noneikonal expression for the two-body scattering amplitude, consistent with the proton-nucleon scattering data, the cross-section of the 1.04 GeV-proton elastic scattering on {sup 40}Ca is calculated by the Glauber-Sitenko theoretical scheme in the framework of the coherent density fluctuation model (CDFM) as well as of the independent-particle model (IPM). It is shown that the use of the noneikonal amplitude in the CDFM calculations improves the agreement with the experimental data especially at larger scattering angles in contrast to the case of the independent-particle model. To that end a decisive role play the zero-motion flucton correlations taken into account in the CDFM. (orig.).

1990-07-01

344

Zero-motion correlations in high-energy proton elastic scattering on "4"0Ca with noneikonal nucleon-nucleon amplitude  

International Nuclear Information System (INIS)

Using a noneikonal expression for the two-body scattering amplitude, consistent with the proton-nucleon scattering data, the cross-section of the 1.04 GeV-proton elastic scattering on "4"0Ca is calculated by the Glauber-Sitenko theoretical scheme in the framework of the coherent density fluctuation model (CDFM) as well as of the independent-particle model (IPM). It is shown that the use of the noneikonal amplitude in the CDFM calculations improves the agreement with the experimental data especially at larger scattering angles in contrast to the case of the independent-particle model. To that end a decisive role play the zero-motion flucton correlations taken into account in the CDFM. (orig.).

345

X-ray Phase Imaging Microscopy using a Fresnel Zone Plate and a Transmission Grating  

International Nuclear Information System (INIS)

We report on a hard X-ray phase imaging microscopy (a phase-difference microscopy) that consists of an objective and a transmission grating. The simple optical system provides a quantitative phase image, and does not need a wave field mostly coherent on the objective. Our method has a spatial resolution almost same as that of the absorption contrast microscope image obtained by removing the grating. We demonstrate how our approach provides a phase image from experimentally obtained images. Our approach is attractive for easily appending a quantitative phase-sensitive mode to normal X-ray microscopes, and has potentially broad applications in biology and material sciences.

2010-06-23

346

What density-functional theory can tell us about the spin-density wave in  

International Nuclear Information System (INIS)

The energy-versus-volume curve of the spin-density wave (SDW) in body-centred-cubic Cr is calculated with the density functional theory/full-potential linearized augmented plane wave (DFT/FLAPW) method using the generalized gradient approximation (GGA). The predicted ground state is not the SDW, in contrast to an earlier FLAPW calculation. A conjecture is formulated that the widely varying results of the local density approximation (LDA) and GGA - and of different solution methods - can be scaled by the size of the calculated moment. As a consequence, experimentally relevant properties of the SDW can be calculated by tuning the moment. The implications of these results for the ability of DFT to describe Cr are discussed. (author)

2002-04-01

347

Waterlogging-induced increase in sugar mobilization, fermentation, and related gene expression in the roots of mung bean (Vigna radiata)  

British Library Electronic Table of Contents (United Kingdom)

Summary The objective of this study was to examine the role of root carbohydrate levels and metabolism in the waterlogging tolerance of contrasting mung bean genotypes. An experiment was conducted with two cultivated mung bean (Vigna radiata) genotypes viz., T44 (tolerant) and Pusa Baisakhi (PB) (susceptible), and a wild Vigna species Vigna luteola under pot-culture to study the physiological and molecular mechanism of waterlogging tolerance. Waterlogging resulted in decrease in relative water content (RWC), membrane stability index (MSI) in root and leaf tissues, and chlorophyll (Chl) content in leaves, while the Chl a/b ratio increased. Waterlogging-induced decline in RWC, MSI, Chl and increase in Chl a/b ratio was greater in PB than V. luteola and T44. Waterlogging caused decline in tot...

2009-01-01

348

Visualization of disturbed flow with spin-echo and cine MR imaging  

International Nuclear Information System (INIS)

MR images of steady and pulsatile disturbed flow, obtained with use of flow-compensated spin-echo (SE) and cine pulse sequences, revealed excellent flow visualization in three dimensions. Phantoms, built from molds of actual blood vessels, reproduced laminar, disturbed, or turbulent flow. Video recording (VR), performed under conditions equivalent to those of the MR experiments, showed separation zones identical to those seen on SE images. Pulsatile flow studies showed complex patterns of vortical flow on cine images and VR. Varying pulse sequence details changed contrast but not flow patterns. The validation of MR observations by VR has implications for clinical cine imaging and low abnormal signals observed on MR angiograms.

349

Variational method for estimating the rate of convergence of Markov Chain Monte Carlo algorithms  

CERN Document Server

We demonstrate the use of a variational method to determine a quantitative lower bound on the rate of convergence of Markov Chain Monte Carlo (MCMC) algorithms as a function of the target density and proposal density. The bound relies on approximating the second largest eigenvalue in the spectrum of the MCMC operator using a variational principle and the approach is applicable to problems with continuous state spaces. We apply the method to one dimensional examples with Gaussian and quartic target densities, and we contrast the performance of the basic Metropolis-Hastings algorithms with a ``smart'' variant that incorporates gradient information into the trial moves. We find that the variational method agrees quite closely with numerical simulations. We also see that the smart MCMC algorithm often fails to converge geometrically in the tails of the target density except in the simplest case we examine, and even then care must be taken to choose the appropriate ...

2006-01-01

350

Use of a novel acoustic dissolved oxygen transmitter for fish telemetry  

DEFF Research Database (Denmark)

The multiple responses of fishes to changes in dissolved oxygen saturations have been studied widely in the laboratory. In contrast only few studies have included field observations. The objective of the present study was to evaluate the performance of a novel acoustic dissolved oxygen transmitter for field biotelemetry. The results demonstrated that the output of the transmitter was unaffected by three different temperatures (10 to 30 degrees C) and described the dissolved oxygen saturation with high accuracy (r(2) > 0.99) over the entire range of 0 to 191% saturation. The response time (>= 90% of end value) of the transmitter was 12 s both in terms of decreasing (100 to 0%) and increasing (0 to 100%) oxygen saturations. When externally attached to fishes the present findings support the use of the transmitter for reliable dissolved oxygen measurements on individuals living in environments that may change both temporally and spatially with regard to ambient ...

2006-01-01

351

Uranium Mass and Isotopic Analysis. A new drum tomographic gamma scanning system  

Energy Technology Data Exchange (ETDEWEB)

The NIS-6 group at Los Alamos National Laboratory pioneered the development of Tomographic Gamma Scanning and continue to improve its utility in real measurement situations. Building on this experience we report the development of a state of the art TGS system suitable for industrial applications. The image reconstruction and visualization software has been integrated into the familiar Canberra NDA2000 software suite which also handles all other aspects of the data acquisition and management. In this paper we describe the salient design and performance parameters of the system. The application of gamma-ray tomography to safeguards for improved assay accuracy and knowledge confirmation is discussed. In particular we compare and contrast the relative merits of this TGS and a traditional Segmented Gamma Scanner and illustrate how the 3-D visualization of the TGS image can provide valuable additional information.

2003-05-01

352

Towards atomic scale engineering of rare-earth-doped SiAlON ceramics through aberration-corrected scanning transmission electron microscopy  

British Library Electronic Table of Contents (United Kingdom)

Direct visualization of rare earths in @a- and @b-SiAlON unit-cells is performed through Z-contrast imaging technique in an aberration-corrected scanning transmission electron microscope. The preferential occupation of Yb and Ce atoms in different interstitial locations of @b-SiAlON lattice is demonstrated, yielding higher solubility for Yb than Ce. The triangular-like host sites in @a-SiAlON unit cell accommodate more Ce atoms than hexagonal sites in @b-SiAlON. We think that our results will be applicable as guidelines for many kinds of rare-earth-doped materials.

2011-01-01

353

Tin doping in spray pyrolysed indium sulfide thin films for solar cell applications  

British Library Electronic Table of Contents (United Kingdom)

This paper presents studies carried out on tin-doped indium sulfide films prepared using Chemical Spray Pyrolysis (CSP) technique. Effect of both in-situ and ex-situ doping were analyzed. Ex-situ doping was done by thermal diffusion, which was realized by annealing Sn/In2S3 bilayer films. In-situ doping was accomplished by introducing Sn into the spray solution by using SnCl45H2O. Interestingly, it was noted that by ex-situ doping, conductivity of the sample enhanced considerably without affecting any of the physical properties such as crystallinity or band gap. Analysis also showed that higher percentage of doping resulted in samples with low crystallinity and negative photosensitivity. In-situ doping resulted in amorphous films. In contrast to ex-situ doping, `in- situ doping' resulted i...

2010-01-01

354

Thermal Casimir-van der Waals Interaction between Randomly Charged Dielectrics  

CERN Document Server

Monopolar charge disorder effects are studied in the context of fluctuation-induced interactions between neutral dielectric slabs. It is shown that quenched bulk charge disorder gives rise to an additive contribution to the net interaction force which decays as the inverse distance between dielectric surfaces. This effect may thus completely mask the standard Casimir--van der Waals effect. By contrast, annealed (bulk or surface) charge disorder leads to a net interaction force whose large-distance behavior coincides with the universal Casimir force between perfect conductors, which scales as inverse cubic distance, and the dielectric properties enter only in subleading corrections.

2009-01-01

355

The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma  

International Nuclear Information System (INIS)

The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).

356

The segmental gastrocnemius muscles' flap: A cadaveric study  

British Library Electronic Table of Contents (United Kingdom)

The aim of this study was to evaluate the feasibility of splitting each head of the gastrocnemius muscle into two segments. This prospective study was conducted on 35 fresh cadavers with injection of radio-opaque contrast material in the popliteal artery. Seventy medial gastrocnemius and 70 lateral gastrocnemius muscle specimens were obtained. Gastrocnemius intramuscular arterial anatomy was analysed by using the digital X-ray technique. The most common vascular pattern found in this study was both bellies supplied by individual sural arteries, which shows distal bifurcation. The medial sural artery always showed bifurcation in the medial gastrocnemius muscle in both lower limbs, whereas this bifurcation of the lateral sural artery was present in only 87% cases and 13% of cases showed a si...

2011-01-01

357

The role of water and oxygen impurities on ozone production in a negative corona discharge of CO_2  

International Nuclear Information System (INIS)

The production of ozone in a negative corona discharge fed by carbon dioxide with embedded traces of oxygen and water has been studied. The presence of traces of oxygen in both pure and dry CO_2 leads to an increase in nascent ozone concentrations. In contrast, traces of water vapour (0-800 ppm) are shown to rapidly suppress ozone concentrations with the largest decreases being observed at lowest gas pressures in the discharge (300 Torr). The presence of water vapour did not considerably affect the electrical properties of negative dc corona suggesting that a chemical process is responsible for the ozone loss. We have shown that the addition of water up to a concentration of 1500 ppm has only a marginal effect on the processes of ozone formation but the catalytic cycle of ozone destruction involving OH radicals can be the reason for observed decrease in the total ozone concentration with increasing water concentration.

2007-11-07

358

The influence of contrasting suspended particulate matter transport regimes on the bias and precision of flux estimates  

British Library Electronic Table of Contents (United Kingdom)

A large database (507 station-years) of daily suspended particulate matter (SPM) concentration and discharge data from 36 stations on river basins ranging from 600?km2 to 600,000?km2 in size (USA and Europe) was collected to assess the effects of SPM transport regime on bias and imprecision of flux estimates when using infrequent surveys and the discharge-weighted mean concentration method. By extracting individual SPM concentrations and corresponding discharge values from the database, sampling frequencies from 12 to 200 per year were simulated using Monte Carlo techniques. The resulting estimates of yearly SPM fluxes were compared to reference fluxes derived from the complete database. For each station and given frequency, bias was measured by the median of relative errors between estima...

2006-01-01

359

The external water footprint of the Netherlands: Geographically-explicit quantification and impact assessment  

British Library Electronic Table of Contents (United Kingdom)

This study quantifies the external water footprint of the Netherlands by partner country and import product and assesses the impact of this footprint by contrasting the geographically-explicit water footprint with water scarcity in the different parts of the world. The total water footprint of the Netherlands is estimated to be about 2300 m^3/year/cap, of which 67% relates to the consumption of agricultural goods, 31% to the consumption of industrial goods, and 2% to domestic water use. The Dutch water footprint related to the consumption of agricultural goods, is composed as follows: 46% related to livestock products; 17% oil crops and oil from oil crops; 12% coffee, tea, cocoa and tobacco; 8% cereals and beer; 6% cotton products; 5% fruits; and 6% other agricultural products. About 11% o...

2009-01-01

360

The effects of high-intensity pulsed electromagnetic field on proliferation and differentiation of neural stem cells of neonatal rats in vitro  

British Library Electronic Table of Contents (United Kingdom)

Summary The effects of high-intensity pulsed electromagnetic stimulation (HIPEMS) on proliferation and differentiation of neonatal rat neural stem cells in vitro were investigated. Neural stem cells derived from neonatal rats were exposed to 0.1 Hz, 0.5-10 Tesla (T) [8 groups of B-I, respectively], 5 stimuli of HIPEMF. The sham exposure controls were correspondingly established. Inverted phase contrast microscope was used to observe the cultured cells, MTT assay to detect the viability of the cells as expressed by absorbance (A) value, and flow cytometry to measure differentiation of neural stem cells. The results showed that A values of neural stem cells in both 3.0 T and 4.0 T groups were significantly higher than the other groups 24 to 168 h post HPEMS, indicating a strong promotion of ...

2009-01-01

361

The effect of trace elements on the fatigue behaviour of a carbide-hardened Fe-Ni-Cr alloy. Der Effekt von Spurenelementen auf das Zeitstandverhalten einer karbidverfestigten Fe-Ni-Cr-Legierung  

Energy Technology Data Exchange (ETDEWEB)

Fatigue tests were accomplished with a series of specimens doped with trace elements of a hardened Fe-Ni-Cr alloy, cast and hardened with intermetallic phases for determining the influence of these elements on the high temperature strength properties. The results of extensive fatigue tests show that even small contents of Te, Bi, Se, Pb, Tl and Zn considerably influence the life and creep processes especially after longer running periods, when added individually or combinedly. In contrast to this, the fatigue ductility is reduced by trace element additions even with short running periods. The order in which the metallic trace elements influence the fatigue properties nearly correlates with earlier work concerning Ni- and Co-superalloys. (orig.)

1993-01-01

362

The effect of V and W addition on the high temperature strength properties of 12%Cr-15%Mn austenitic steels  

International Nuclear Information System (INIS)

The effect of W and V on the high temperature strength properties of 12%Cr-15%Mn austenitic steels was studied from the view point of precipitation hardening and internal stress. The contribution of W addition to the tensile and creep-rupture strength was not so large. By contrast the combined addition of W and V increased the strength considerably. These are resulted from the precipitation of fine vanadium nitride (VN) within grains and the enhancement of M_2_3C_6 type carbide precipitation at grain boundaries. The V added material had large internal stress value which is considered to be due to dislocation movement disturbed by fine vanadium nitrides. (author).

363

The approximate maximum-likelihood certificate  

CERN Document Server

A new property which relies on the linear programming (LP) decoder, the approximate maximum-likelihood certificate (AMLC), is introduced. When using the belief propagation decoder, this property is a measure of how close the decoded codeword is to the LP solution. Using upper bounding techniques, it is demonstrated that the conditional frame error probability given that the AMLC holds is, with some degree of confidence, below a threshold. In channels with low noise, this threshold is several orders of magnitude lower than the simulated frame error rate, and our bound holds with very high degree of confidence. In contrast, showing this error performance by simulation would require very long Monte Carlo runs. When the AMLC holds, our approach thus provides the decoder with extra error detection capability, which is especially important in applications requiring high data integrity.

2011-01-01

364

The Interaction of Body, Things and the Others in Constituting Feminine Identity in Lower Socio-Economic Ranks of Bam, Iran  

British Library Electronic Table of Contents (United Kingdom)

Identity is one of the most important matters in social theory, especially in recent decades. Identity is a fluid phenomenon which forms in the process of every day activities. Individuals get practical knowledge of society to do intentional practices. They operate actively in identitizing process. Gender identity is one of important dimensions of individual identities constituting in social relations to others. Different socio-economic classes experience different social relations and engage in different identity processes. This research studies the formation process of feminine identity in the process of marriage (in contrast with the concept of virginity) in lower socio-economic classes of Bam. Body as site of identity and focus of close contact between agency and structure becomes the ...

2011-01-01

365

The Adrenal Mass: Correlation of Histopathology with Imaging  

British Library Electronic Table of Contents (United Kingdom)

Background Computed tomography (CT) and magnetic resonance (MR) imaging can help diagnose benign adrenal adenomas, but prior studies rely on nonoperative follow-up as proof of a lesion?s benign nature. We examined adrenalectomy tissues to determine if imaging characteristics correlate with histopathologic findings. Methods We retrieved data for 196 consecutive adrenalectomies in 192 patients from 2000 to 2008. Imaging results were considered to signify benign adrenal adenoma if one or more of the following was present: Hounsfield units 60% or relative contrast washout of >40%, or MR with chemical-shift imaging demonstrating loss of signal intensity on out-of-phase images. Results The sensitivity and specif...

2010-01-01

366

Tensor network states and geometry  

CERN Document Server

Tensor network states are used to approximate ground states of local Hamiltonians on a lattice in D spatial dimensions. Different types of tensor network states can be seen to generate different geometries. Matrix product states (MPS) in D=1 dimensions, as well as projected entangled pair states (PEPS) in D>1 dimensions, reproduce the D-dimensional physical geometry of the lattice model; in contrast, the multi-scale entanglement renormalization ansatz (MERA) generates a (D+1)-dimensional holographic geometry. Here we focus on homogeneous tensor networks, where all the tensors in the network are copies of the same tensor, and argue that certain structural properties of the resulting many-body states are preconditioned by the geometry of the tensor network and are therefore largely independent of the choice of variational parameters. Indeed, the asymptotic decay of correlations in homogeneous MPS and MERA for D=1 systems is seen to be determined by the structure ...

2011-01-01

367

Synthesis and tissue distribution study of iodine-labeled benzyl- and xylylamines  

International Nuclear Information System (INIS)

Four "1"2"5I labeled mono- and diamines were prepared and evaluated as potential brain-imaging agents. The diamines are analogues of the previously reported "7"5Se labeled diamines, which show high brain uptake and retention. All of the radioiodinated amines display high initial brain uptake in rats after intravenous injection (1.7-2.4% dose/organ). The xylylenediamines show prolonged brain retention (t1/2 approximately 18 h), which is desirable for brain imaging. In contrast, the benzylamine is rapidly cleared from brain tissue (t1/2 approximately 15 min).

368

Synthesis and biodistribution of "9"9"mTc-peptides conjugated adenine as tumor imaging agents  

International Nuclear Information System (INIS)

Two peptide ligands conjugated adenine, [9-N-(tritylmercapto acetyl diglycyl aminoethyl) adenine, Tr-MAG_2-Ade] and [9-N-(tritylmercapto acetyl triglycyl aminoethyl) adenine, Tr-MAG3-Ade], are synthesized and labeled with "9"9"mTc by directly labeling method. The stability of "9"9"mTc-MAG_2- adenine and "9"9"mTc-MAG_3-adenine in vitro is measured. The uptake radios of tumor to muscle at 3h post-injection are 5.70 and 4.92, respectively. The biodistribution and scintigraphic imaging studies show that the two complexes have high localization in tumor and high contrasted tumor images can be obtained, which suggest their potential utility as tumor imaging agents. But the high radioactivity of abdomen could prevent the tumor imaging in this area. (author)

2007-07-01

369

Surface damage of mold steel and its influence on surface roughness of injection molded plastic parts  

British Library Electronic Table of Contents (United Kingdom)

Plastic injection molds are an important economic sector due to the increasing use of injection molded plastic components. The selection of mold steel material, its processing conditions, and the way it is machined and hardened all have an impact on how it performs during use across its lifecycle for injection molding. For this study, injection molding conditions seen during high volume manufacturing were used to induce wear that would be typical during processing. A 50wt.% glass fiber reinforced Polybutylene Terephthalate (PBT) was used for the research. After 3000 injection operations, surface damage was found only on the steel used for the stationary half of the mold cavity and the corresponding surface of the molded parts. In contrast, the moving half showed no surface damage or increa...

2011-01-01

370

Sucrose synthesizing enzymes and /sup 14/C-assimilation in the chlorophyllous layer of developing grapefruit. [Citrus paradisi Macf  

Energy Technology Data Exchange (ETDEWEB)

Fixation of /sup 14/CO/sub 2/ and activities of sucrose-synthesizing enzymes, sucrose phosphate synthetase (SPS) and sucrose synthase (SS), were assayed in tissues of developing fruit and source leaves from Citrus paradisi Macf. SPS activity of both the outer, chlorophyllous layer of the fruit (flavedo) and source leaves was 10-fold greater than that of the inner, largely non-chlorophyllous layer of the fruit peel (albedo). In contrast, SS activity of the flavedo was 2-fold greater than that of the albedo and 10-fold greater than that of leaves. Fixation of /sup 14/C-photosynthates in isolated tissues (flavedo 2x > albedo) and their redistribution in intact fruit indicated that flavedo functions as both source and sink. Activities of sucrose-synthesizing enzymes were consistent with this dual function.

1986-04-01

371

Structures in the Universe and Origin of Galaxies  

CERN Document Server

The analysis of images (of obtained in various ranges of the lengths of waves) of luminous objects in the Universe by means of a method of multilevel dynamic contrasting led author to the conclusions: a) the structures of all observable galaxies represents a complicated constructions which have the tendency to self-similarity and made of separate (basic) blocks, which are a coaxially tubular structures and a cartwheel-like structures; b) the majority of observable objects in the Universe are luminous butt-ends of almost invisible (of almost completely transparent) of filamentary formations which structures are seen only near to their luminous butt-ends; c) the result of analysis of images of cosmic objects show the structure of many pairs of cooperating galaxies point to opportunity of their formation at butt-ends generated in a place of break of the similar filament; d) the interacting galaxies (M 81 and M 82) show they are butt-ends of sawed off of two branches ...

2005-01-01

372

Spin transition in octahedral metal complexes containing tetraazamacrocyclic ligands  

British Library Electronic Table of Contents (United Kingdom)

This review focusses on spin crossover complexes with octahedral metal ions which are bound to a tetraazamacrocyclic ligand and additionally either to two monodentate ligands or to one bidentate ligand. Macrocyclic ligands with a sufficiently large ring size prefer to coordinate to metal ions in an equatorial fashion yielding trans-octahedral coordination environments. In contrast, twelve-membered tetraazamacrocycles with high steric rigidity, such as 2,11-diaza[3.3](2,6)pyridinophanes or 2,11-dithia[3.3](2,6)pyridinophane, are prone to form cis-octahedral complexes. While the electronic and the steric properties of the coordinated tetraazamacrocycle in trans-octahedral complexes are very likely responsible for the paucity of observed spin transitions, the cis-octahedral coordination mode ...

2009-01-01

373

Solar receiver-reactor with specularly reflecting walls for high-temperature thermoelectrochemical and thermochemical processes. Technical report  

Energy Technology Data Exchange (ETDEWEB)

A new kind of receiver-reactor for high-temperature solar furnaces is proposed. The main body of the receiver component is an ellipsoid of revolution with specularly reflecting inner walls. The reactor component, a crucible, is placed at one focal point and the aperture at the other. With this arrangement, substantially all of the incident radiation from the concentrator should reach the reactor directly or after one reflection from the cavity walls. An analysis of the radiative exchange among the surfaces is presented. The analysis provides a tool for a parametric study and optimization of the design. It is found that, in contrast to that of conventional well-insulated cavity receivers, its collection efficiency is not very sensitive to the size of its aperture.

1987-10-27

374

Sensors to detect CO based in SnO. Sensores para detectar CO basados en SnO  

Energy Technology Data Exchange (ETDEWEB)

The development of solid state chemical sensors, and more specifically of gas sensors, is carried out with great strength in the present time since the environmental pollution and the security in work and domestic ambient are problems of great interest and social impact. The main fields of application, are: automobile, domestic sensors, control of industrial process, bio medicine, environment. These chemical sensors are experimenting a great advance because of the advantages they offer, as low cost, simple operation, possibility of measure continuous and ''In situ'' and small size, in contrast with analytical techniques that need complex instrumentation and large size equipments. In the present work, a sensor for CO detecting concentrations as low as 50 p.p.m., is studied showing great interest since this gas is highly toxic even to such a low concentration. (Author)

1993-01-01

375

Self-Objectification and Pregnancy: Are Body Functionality Dimensions Protective?  

British Library Electronic Table of Contents (United Kingdom)

Objectification theory contends that women are socialized to view their body as an object to be evaluated by others (Fredickson and Roberts 1997). In contrast, pregnancy may be a time that women are more attuned to their body?s functionality. Extending objectification theory, we investigate relationships among body surveillance, awareness and appreciation of body functionality, depressive symptoms, and prenatal health behaviors among an on-line sample of 156 predominantly White, middle-class pregnant women from throughout the U.S recruited through maternity stores, message boards, listservs, and snowballing techniques. We examine whether higher levels of awareness and appreciation of body functionality may attenuate, and thereby possibly protect women from the negative effects of high body...

2011-01-01

376

Seasonal variations of Zn, Cu, As and Mo in arsenic-rich stream at the Mokrsko gold deposit, Czech Republic  

British Library Electronic Table of Contents (United Kingdom)

Monthly sampling of slightly alkaline arsenic-rich stream in the Mokrsko gold deposit revealed seasonal variations in dissolved Zn, Cu, As and Mo. Concentrations of trace metal cations (Zn, Cu) increased as much as 330 and 178%, respectively, from minimum mean values at autumn to maximum mean values at spring. In contrast, concentrations of trace element oxyanions (As, Mo) revealed opposite seasonal pattern with increase to 189% (As) and 123% (Mo) during summer?autumn, indicating that in-stream biogeochemical process(es) played the main role in controlling the seasonal variations of these trace elements. The trace elements were mainly scavenged by low crystalline Mn oxyhydroxide and Fe oxyhydroxide (ferrihydrite). Results are consistent with sorption and coprecipitation processes controlli...

2011-01-01

377

Running couplings and operator mixing in the gravitational corrections to coupling constants  

CERN Document Server

The use of a running coupling constant in renormalizable theories is well known, but the implementation of this idea for effective field theories with a dimensional coupling constant is in general less useful. Nevertheless there are multiple attempts to define running couplings including the effects of gravity, with varying conclusions. We sort through many of the issues involved, most particularly the idea of operator mixing and also the kinematics of crossing, using calculations in Yukawa and lambda phi^4 theory as illustrative examples. We remain in the perturbative regime. In some theories with a high permutation symmetry, such as lambda phi^4, a reasonable running coupling can be defined. However in most cases, such as Yukawa and gauge theories, a running coupling fails to correctly account for the energy dependence of the interaction strength. As a byproduct we also contrast on-shell and off-shell renormalizaton schemes and show that operators which are ...

2010-01-01

378

Result analysis on the parameter test of radium specific activity calculation in the tailing of uranium mine No. 794  

International Nuclear Information System (INIS)

This paper first introduces the calculating method of radium specific activity to determine the radon emanation rate of tailing of uranium mine No. 794, the method needs two parameters: radon emanation coefficient and radon diffusion coefficient. According to the measured results of parameters and the contrast between radium specific activity of indoor chemical analysis of field sample and field gamma-ray spectra, the authors discuss the variation rules and characteristics of radon emanation coefficient and radon diffusion coefficient, and the best climate and seasons for measuring these parameters in northern China, and finally summarize the characteristics of this method through analyzing measured results. (authors)

2006-09-01

379

Recycling and ?re-hydration? of degassed magma inducing transient dissolution/crystallization events at Stromboli (Italy)  

British Library Electronic Table of Contents (United Kingdom)

Intrusive degassing and recycling of degassed and dense magma at depth have been proposed for a long time at Stromboli. The brief explosive event that occurred at the summit craters on 9 January 2005 threw out bombs and lapilli that could be good candidates to illustrate recycling of shallow degassed magma at depth. We present an extensive data set on both the textures and the mineral, bulk rock and glassy matrix chemistry of the ?9 Jan? products. The latter have the common shoshonitic?basaltic bulk composition of lavas and scoriae issued from typical strombolian activity. In contrast they differ by the heterogeneous chemistry of their matrix glasses and their crystal textures that testify to crystal dissolution event(s) just prior magma crystallization upon ascent and eruption. Comparison...

2008-01-01

380

Real-time neutron radiography for visualisation of interfacial geometry and phase distribution in two-phase flow  

International Nuclear Information System (INIS)

Results of ongoing research project at the McMaster Nuclear Reactor Facility on real-time neutron radiography for the visualization of interfacial geometry, movements and phase distributions in gas-liquid and gas-liquid-metal multi-phase flows are presented. Experiments were conducted with bubble column tubes with boiling liquid nitrogen, air-water and air-mercury mixtures. Discussions are also focused on air-water flowing within a tube containing a CANDU type 37 rod fuel bundle assembly positioned both horizontally and vertically. Computer processing using a digital image format to enhance the real-time images was used. Imaging techniques include frame averaging, background substraction, edge enhancement (spatial filtering), contrast enhancement and video densitometry. (orig.).

1989-10-01

381

Real time study of the crystallization of aluminium-base icosahedral phases by neutron powder diffraction  

International Nuclear Information System (INIS)

The thermal transformation of Al-base icosahedral phases was studied in-situ by real time neutron powder diffraction. Different compositions have been selected in order to vary the initial phase morphology and change the neutron scattering contrast between species. Alloys with low silicon and large aluminium contents produce first the orthorhombic O-Al_6Mn modification. In alloys with larger silicon content, the #alpha#-AlMnSi cubic phase appears soon after the beginning of the transformation but is still preceeded by O-Al_6Mn. Depending on compositions, the crystallization of the icosahedral phase is controlled either by the diffusion of Al through its interface with the residual fcc aluminium or that of Si within the bulk. The results are discussed in the light of current structural models. (author) 40 refs., 14 figs., 3 tabs.

1987-01-01

382

Radiosensitization of human lung fibroblasts by chemicals that decrease ATP levels  

International Nuclear Information System (INIS)

Radiosensitization by lactate, pyruvate, nalidixic acid and novobiocin was studied in exponentially growing SH-18L human lung fibroblasts. All the chemicals had a slight radiosensitizing effect at a low concentration and a definite effect at a higher one. Decreases in the D_0 and/or Dq values were present in each dose survival curve. Fibroblasts incubated with the low concentration of each chemical for 24 hrs after X irradiation showed no reduction in intracellular ATP content, whereas, the higher concentration produced a significant decrease. These observations suggest that the decrease in the ATP content may be involved in the radiosensitization of human fibroblasts at high concentrations of these chemicals. In contrast, radiosensitization at a low concentration is not explained by a relationship to ATP content. Different mechanisms may be involved in radiosensitization at low and high concentrations of these chemicals. (author).

383

Quark-hadron duality in neutrino scattering  

Energy Technology Data Exchange (ETDEWEB)

We present a phenomenological model of the quark-hadron transition in neutrino-nucleon scattering. Using recently extracted weak nucleon transition form factors, we investigate the extent to which local and global quark-hadron duality is applicable in the neutrino F{sub 1}, F{sub 2} and F{sub 3} structure functions, and contrast this with duality in electron scattering. Our findings suggest that duality works relatively well for neutrino-nucleon scattering for the F{sub 2} and F{sub 3} structure functions, but not as well for F{sub 1}. We also calculate the quasi-elastic, resonance and deep inelastic contributions to the Adler sum rule, and find it to be satisfied to within 10% for 0.5 < Q{sup 2} < 2 GeV{sup 2}.

2006-07-24

384

Quantum corrections to the Larmor radiation formula in scalar electrodynamics  

CERN Document Server

We use the semi-classical approximation in perturbative scalar quantum electrodynamics to calculate the quantum correction to the Larmor radiation formula to first order in Planck's constant in the non-relativistic approximation, choosing the initial state of the charged particle to be a momentum eigenstate. We calculate this correction in two cases: in the first case the charged particle is accelerated by a time-dependent but space-independent vector potential whereas in the second case it is accelerated by a time-independent vector potential which is a function of one spatial coordinate. We find that the corrections in these two cases are different even for a charged particle with the same classical motion. The correction in each case turns out to be non-local in time in contrast to the classical approximation.

2009-01-01

385

Quantitative measurements of injections into porous media with contrast based MRI  

British Library Electronic Table of Contents (United Kingdom)

Porous flow occurs in a wide range of materials and applies to many commercially relevant applications such as oil recovery, chemical reactors and contaminant transport in soils. Typically, breakthrough and pressure curves of column floods are used in the laboratory characterization of these materials. These characterization methods lack the detail to easily and unambiguously resolve flow mechanisms with similar effects at the core scale that can dominate at the aquifer or oil field scale, as well as the effects of geometry that control the flow at interfaces as in a perforated well or the inlet of an improperly designed column. Non-invasive imaging techniques such as MRI have been shown to provide a far more detailed characterization of the properties of the solid matrix and flow, but usu...

2011-01-01

386

Quantification of order in the liquid at a solid-liquid interface by High-Resolution Transmission Electron Microscopy (HRTEM)  

Energy Technology Data Exchange (ETDEWEB)

A number of different theoretical approaches have been used to model to atomic structure and properties of solid-liquid interfaces. Most calculations indicate that ordering occurs in the first several layers of the liquid, adjacent to the crystal surface. In contrast to the numerous theoretical investigations, there have been no direct experimental observations of the atomic structure of a solid-liquid interface for comparison. Saka et al. examined solid-liquid interfaces in In and In-Sb at lattice-fringe resolution in the TEM, but their data do not reveal information about the atomic structure of the liquid phase. The purpose of this study is to determine the atomic structure of a solid-liquid interface using a highly viscous supercooled liquid, i.e., a crystal-amorphous interface.

1996-12-31

387

Profiling gene expression responses of coral larvae (Acropora millepora) to elevated temperature and settlement inducers using a novel RNA-Seq procedure  

British Library Electronic Table of Contents (United Kingdom)

Abstract Elevated temperatures resulting from climate change pose a clear threat to reef-building corals; however, the traits that might influence corals- survival and dispersal during climate change remain poorly understood. Global gene expression profiling is a powerful hypothesis-forming tool that can help elucidate these traits. Here, we applied a novel RNA-Seq protocol to study molecular responses to heat and settlement inducers in aposymbiotic larvae of the reef-building coral Acropora millepora. This analysis of a single full-sibling family revealed contrasting responses between short- (4-h) and long-term (5-day) exposures to elevated temperatures. Heat shock proteins were up-regulated only in the short-term treatment, while the long-term treatment induced the down-regulation of rib...

2011-01-01

388

Point-contact Andreev reflection spectroscopy of heavy-fermion-metal/superconductor junctions  

Energy Technology Data Exchange (ETDEWEB)

Our previous point-contact Andreev reflection studies of the heavy-fermion superconductor CeCoIn{sub 5} using Au tips have shown two clear features: reduced Andreev signal and asymmetric background conductance. To explore their physical origins, we have extended our measurements to point-contact junctions between single crystalline heavy-fermion metals and superconducting Nb tips. Differential conductance spectra are taken on junctions with three heavy-fermion metals, CeCoIn{sub 5}, CeRhIn{sub 5}, and YbAl{sub 3}, each with different electron mass. In contrast with Au/CeCoIn{sub 5} junctions, Andreev signal is not reduced and no dependence on effective mass is observed. A possible explanation based on a two-fluid picture for heavy fermions is proposed.

2008-04-01

389

Point -contact Andreev reflection spectroscopy of heavy-fermion-metal/superconductor junctions  

Energy Technology Data Exchange (ETDEWEB)

Our previous point-contact Andreev reflection studies of the heavy-fermion superconductor CeCoIn{sub 5} using Au tips have shown two clear features: reduced Andreev signal and asymmetric background conductance. To explore their physical origins, we have extended our measurements to point-contact junctions between single crystalline heavy-fermion metals and superconducting Nb tips. Differential conductance spectra are taken on junctions with three heavy-fermion metals, CeCoIn{sub 5}, CeRhIn{sub 5}, and YbAl{sub 3}, each with different electron mass. In contrast with Au/CeCoIn{sub 5} junctions, Andreev signal is not reduced and no dependence on effective mass is observed. A possible explanation based on a two-fluid picture for heavy fermions is proposed.

2008-01-01

390

Photovoltaic applications for off-grid electrification using novel multi-level inverter technology with energy storage  

British Library Electronic Table of Contents (United Kingdom)

In areas where grid connection is difficult and costly, the use of renewable energy is both economically and environmentally advantageous. Due to typically low system efficiency (10%) and intermittency of photovoltaic (PV) electricity generation, a new design of multi-level H-bridge inverter technology is considered. This multi-level technology increases DC to AC conversion efficiency and the design includes battery energy storage to enable 24/7 operation. The proposed multi-level inverter is compared and contrasted with other existing designs. The proposed cascaded inverter provides lower switching losses, simple switching techniques, modularity, and simpler charge-balancing approaches than conventional technology. A switching technique was designed for the proposed multi-level inverter t...

2012-01-01

391

Photosensitivity and imaging characteristics of ion-implanted PLZT ceramics  

International Nuclear Information System (INIS)

We reported in previous papers that both the near-uv and the visible photosensitivities of ferroelectric-phase PLZT (lead lanthanum zirconate titanate) ceramics are increased by as much as four orders of magnitude by ion implantation or a combination of thermal diffusion of Al and ion implantation. New results are presented here on high-energy (1 MeV) implants of Al and Ni and coimplants of Al + Ne and Ni + Ne, and these results are compared with earlier 500 keV implants of Al and Cr and coimplants of Al + Ne and Cr + Ne as surface modification techniques for increasing the visible photosensitivity of PLZT. The important role of grain size in determining optimum contrast and resolution of stored optical information is described in terms of new experimental results.

1985-08-12

392

Photodestruction of explosives in process water  

Energy Technology Data Exchange (ETDEWEB)

Photodestruction has received much attention in recent years. In particular, titanium dioxide (TiO{sub 2}) and ozonolysis have attained a position of prominence. These technologies hold promise for the destruction of trace amounts of aqueous high explosives that are generated by load and pack operations, as well as demilitarization activities. Currently this water is treated by passing through a bed of activated carbon. The carbon is then steam regenerated and reused, thus creating a second waste stream which must be disposed of, or the carbon is burned directly. Recent trends in environmental regulation have shown that this may not be a viable option for process water remediation in the future. This talk will discuss efforts to employ alternate aqueous treatment techniques that not only remove the explosives compounds but are able to transform the parent compound into carbon dioxide and water. Titanium dioxide photocatalysis as well as UV-ozone photolysis will be compared and ...

1995-12-31

393

Photobiology and photosynthesis  

British Library Electronic Table of Contents (United Kingdom)

To test the hypothesis that leaf level photosynthetic related traits might confer late successionals a competitive advantage over early successionals in low light growth conditions, steady photosynthetic assimilation and dynamic photosynthetic induction related traits were examined in low light grown seedlings with contrasting successional status. Compared with the early successionals, late successionals as a group significantly exhibited lower leaf gas exchange rates. While late successionals required a longer time to respond to simulated sunflecks, they had lower rates of induction losses after sunflecks. Such photosynthetic induction traits allowed late successionals to more effectively utilize subsequent sunflecks. It was observed that plants with lower gas exchange rates responded mor...

2011-01-01

394

Perturbations of Schwarzschild Black Holes in Chern-Simons Modified Gravity  

CERN Document Server

We study perturbations of a Schwarzschild black hole in Chern-Simons modified gravity. We begin by showing that Birkhoff's theorem holds for a wide family of Chern-Simons coupling functions, a scalar field present in the theory that controls the strength of the Chern-Simons correction to the Einstein-Hilbert action. After decomposing the perturbations in spherical harmonics, we study the linearized modified field equations and find that axial and polar modes are coupled, in contrast to general relativity. The divergence of the modified equations leads to the Pontryagin constraint, which forces the vanishing of the Cunningham-Price-Moncrief master function associated with axial modes. We analyze the structure of these equations and find that the appearance of the Pontryagin constraint yields an overconstrained system that does not allow for generic black hole oscillations. We illustrate this situation by studying the case characterized by a canonical choice of the ...

2007-01-01

395

Patterns of proliferation and differentiation of irradiated haemopoietic stem cells cultured on normal 'stromal' cell colonies in vitro  

Energy Technology Data Exchange (ETDEWEB)

Experiments were designed to elucidate whether or not the irradiated bone marrow cells receive any stimulation for the self-replication and differentiation from normal 'stromal' cell colonies in the bone marrow cell culture in vitro. When irradiated or unirradiated bone marrow cells were overlaid on the normal adherent cell colonies, the proliferation of haemopoietic stem cells was supported, the degree of the stimulation depending on the starting cellular concentration. There was, however, no significant changes in the concentration of either CFUs or CFUc regardless of the dose of irradiation on the bone marrow cells overlaid. This was a great contrast to the dose-dependent decrease of CFUs or CFUc within the culture in which both the stem cells and stromal cells were simultaneously irradiated. These results suggest that the balance of self-replication and differentiation of the haemopoietic stem cells is affected only when haemopoietic ...

1981-09-01

396

Pain measurement: the affective dimensional measure of the McGill pain questionnaire with a cancer pain population.  

Science.gov (United States)

Two experiments used the McGill Pain Questionnaire (MPQ) to examine the affective dimension of pain in patients whose pain was secondary to malignancy. In experiment I, segregating groups of cancer patients on the basis of extreme scores (high versus low) on the MPQ failed to produce segregation on independent measures of affect and infirmity. This outcome contrasts with earlier work with chronic benign pain patients. Experiment II compared cancer pain patients matched with benign pain patients on intensity of pain report on the affective dimension of the MPQ. Cancer pain patients reported a reliably higher affective loading to their pain. These data suggest that cancer pain patients employ different criteria than benign pain patients in selecting affective pain descriptors. Possible explanations for this difference are discussed. PMID:7070825

1982-02-01

397

One-step RNA pathogen detection with reverse transcriptase activity of a mutated thermostable Thermus aquaticus DNA polymerase  

British Library Electronic Table of Contents (United Kingdom)

We describe the cloning and characterization of a mutated thermostable DNA polymerase from Thermus aquaticus (Taq) that exhibits an increased reverse transcriptase activity and is therefore designated for one-step PCR pathogen detection using established real-time detection methods. We demonstrate that this Taq polymerase mutant (Taq M1) has similar PCR sensitivity and nuclease activity as the respective Taq wild-type DNA polymerase. In addition, and in marked contrast to the wild-type, Taq M1 exhibits a significantly increased reverse transcriptase activity especially at high temperatures (>60degreeC). RNA generally hosts highly stable secondary structure motifs, such as hairpins and G-quadruplexes, which complicate, or in the worst case obviate, reverse transcription (RT). Thus, RT at hi...

2010-01-01

398

On the relationship between exchange rates and equity returns: A new approach  

British Library Electronic Table of Contents (United Kingdom)

This paper employs a new approach in order to investigate the underlying relationship between stock markets and exchange rates. Current approaches suggest that the relative equity market performance of two countries is linked to their exchange rate. In contrast, this study proposes an alternative approach where one global variable - global equity market returns - is believed to have an effect on exchange rates, with the relative interest rate level of a currency determining the sign of the relationship. Our empirical findings suggest that exchange rates and global stock market returns are strongly linked. The value of currencies with higher interest rates is positively related with global equity returns, whereas the value of currencies with lower interest rates is negatively related with g...

2011-01-01

399

On the premixed combustion in a direct-injection diesel engine  

Energy Technology Data Exchange (ETDEWEB)

The factors influencing premixed burning and the importance of premixed burning on the exhaust emissions from a small high-speed direct-injection diesel engine were investigated. The characteristics of premixed and diffusion burning were examined using a single-zone heat-release analysis. The mass of fuel burned in premixed combustion was found to be linearly related to the product of engine speed and ignition-delay time and to be essentially independent of the total amount of fuel injected. Accordingly, the premixed-burned fraction increased with increasing engine speed, with decreasing fuel-air ratio and with retarding injection timing. The hydrocarbon emissions did not correlate well with the premixed-burned fraction. In contrast, the oxides of nitrogen emissions were found to increase with decreasing premixed-burned fraction, indicating that diffusion burning, and not premixed burning, is the primary source of oxides of nitrogen emissions.

1987-04-01

400

Nuclear magnetic resonance imaging of the abnormal live rat and correlations with tissue characteristics  

Energy Technology Data Exchange (ETDEWEB)

Nuclear magnetic resonance (NMR) images of live rats with sterile and pyogenic abscesses, hematomas, and various implanted and spontaneous neoplasms demonstrated good contrast differentiation between pathologic and surrounding normal tissues. This differentiation was maximal when both the T1 and T2 tissue relaxation times were used as criteria. Neoplasms have a broad range of T1 and T2 values and may be confused with abscesses or hematomas. Tissue rate constants (1/T1 and 1/T2) are mainly dependent on total water content, the exception being fat, which has a 1/T2 value much shorter than that expected on the basis of water content alone.

1981-10-01

401

Non-invasive on-line two-phase flow regime identification employing artificial neural networks  

Energy Technology Data Exchange (ETDEWEB)

A novel non-invasive approach to the on-line identification of BWR two-phase flow regimes is investigated. The proposed approach receives neutron radiography images of coolant flow recordings as its input and performs feature extraction on each image via simple and directly computable statistical operators. The extracted features are subsequently used as inputs to an ensemble of self-organizing maps whose outputs demonstrate swift and accurate classification of each image into its corresponding flow regime. The novelty of the approach lies in the use of the self-organizing map which generates the different classes by itself, according to feature similarity of the corresponding images; this contrasts traditional artificial neural networks where the user has to define both the number of distinct classes as well as to supply separate training vectors for each class.

2009-05-01

402

Nomographic estimation and evaluation of soil erodibility under simulated and natural rainfall conditions  

British Library Electronic Table of Contents (United Kingdom)

To evaluate soil erodibility under different land uses and to study the applicability of nomograph for estimation of soil erodibility a field experiment was conducted under both natural and simulated rainfall conditions under four land uses viz. barren, cultivated, grassland, and forest in the sub-mountainous tract of Punjab (India). Measured soil erodibility (K) values varied from 033 to 067 under natural rainfall conditions and from 023 to 040 under simulated rainfall conditions. Among different land uses, measured K was in the order of barren > cultivated > grassland > forest soils. The values of the K estimated by nomograph were very low as compared to the observed values. The trends were also in contrast to these observed values of K under simulated and natural rainfall conditions. To...

2009-01-01

403

Newtonian photorealistic ray tracing of grating cloaks and correlation-function-based cloaking-quality assessment  

CERN Document Server

Grating cloaks are a variation of dielectric carpet (or ground- plane) cloaks. The latter were introduced by Li and Pendry. In contrast to the numerical work involved in the quasi-conformal carpet cloak, the refractive-index profile of a conformal grating cloak follows a closed and exact analytical form. We have previously mentioned that finite-size conformal grating cloaks may exhibit better cloaking than usual finite-size carpet cloaks. In this letter, we directly visualize their performance using photorealistic ray-tracing simulations. We employ a Newtonian approach that is advantageous compared to conventional ray tracing based on Snell's law. Furthermore, we quantify the achieved cloaking quality by computing the cross-correlations of rendered images. The cross-correlations for the grating cloak are much closer to 100% (i.e., ideal) than those for the Gaussian carpet cloak.

2010-01-01

404

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

405

Negative effective mass below a cut-off frequency  

CERN Document Server

Acoustic metamaterials with negative effective mass below a cut-off frequency are studied. An equivalent mass-spring structure is firstly proposed for such metamaterials, the effective mass is found to follow the Drude model: being negative below a specific frequency. The peculiar behavior is then verified by transmission experiments operating in the low-frequency regime. Inspired by the mass-spring model, we investigate the two-dimensional elastic waveguide with clamped boundaries and attribute the bandgap occurring below a critical frequency to negative effective mass density. The finding helps us to design a new acoustic Drude metamaterial, which enables shearing and bending deformations, in contrast to the membrane-type ones. Both simulation and experimental results show that the proposed metamaterial exhibits negative effective mass below 1200 Hz, thus opening broadband applications in vibration and noise controls.

2010-01-01

406

Musicians demonstrate experience-dependent brainstem enhancement of musical scale features within continuously gliding pitch  

British Library Electronic Table of Contents (United Kingdom)

In contrast to language, where pitch patterns consist of continuous and curvilinear contours, musical pitch consists of relatively discrete, stair-stepped sequences of notes. Behavioral and neurophysiological studies suggest that both tone-language and music experience enhance the representation of pitch cues associated with a listener's domain of expertise, e.g., curvilinear pitch in language, discrete scale steps in music. We compared brainstem frequency-following responses (FFRs) of English-speaking musicians (musical pitch experience) and native speakers of Mandarin Chinese (linguistic pitch experience) elicited by rising and falling tonal sweeps that are exemplary of Mandarin tonal contours but uncharacteristic of the pitch patterns typically found in music. In spite of musicians' unf...

2011-01-01

407

Monitoring transplanting operation of rice crop using passive microwave radiometer data  

British Library Electronic Table of Contents (United Kingdom)

This study highlights a methodology to detect the transplanting operation of wetland rice at a regional scale using SSM/I brightness temperature in frequencies like 19, 37 and 85 GHz with vertical polarization. A cloud removal algorithm was used to make weekly composites of the brightness temperature, which were used to estimate the soil wetness index (SWI). Flooding of rice fields with water for transplanting induces very high change in SWI due to contrasting dielectric constant of water (80) and soil (4). Different weather conditions and fractional wet area under the footprint of sensor affect SWI, hence absolute value of SWI was not adequate. Therefore, multi-year SWI anomaly was used to generate a threshold value of SWI change to detect when SWI change between two consecutive weeks was...

2011-01-01

408

Molecular evidence for variation in polyandry among praying mantids (Mantodea: Ciulfina)  

British Library Electronic Table of Contents (United Kingdom)

Abstract Estimating paternity patterns provides insights into the importance of competing evolutionary forces on mating systems. The number of sires contributing to a female's offspring is mostly influenced by her relative promiscuity. However, in a postcopulatory context, it will also be affected by sperm competition and cryptic female choice. Here, we describe the paternity patterns of two species of praying mantis from the genus Ciulfina, the agile praying mantid. This study is the first to describe patterns of paternity in the Mantodea. We found a variation in paternity in these two closely related species. Ciulfina rentzi exhibited single paternity, with a single male siring all offspring within a clutch. By contrast, Ciulfina klassi displayed multiple paternity, with the minimum numb...

2011-01-01

409

Modeling Credit Risk with Partial Information  

CERN Document Server

This paper provides an alternative approach to Duffie and Lando [Econometrica 69 (2001) 633-664] for obtaining a reduced form credit risk model from a structural model. Duffie and Lando obtain a reduced form model by constructing an economy where the market sees the manager's information set plus noise. The noise makes default a surprise to the market. In contrast, we obtain a reduced form model by constructing an economy where the market sees a reduction of the manager's information set. The reduced information makes default a surprise to the market. We provide an explicit formula for the default intensity based on an Azema martingale, and we use excursion theory of Brownian motions to price risky debt.

2008-01-01

410

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

411

Marker experiments in growth studies of Ni_2Si, Pd_2Si, and CrSi_2 formed both by thermal annealing and by ion mixing  

International Nuclear Information System (INIS)

Inert markers (evaporated tungsten and silver) were used in growth studies of silicides formed both by thermal annealing and by ion mixing in the Ni/Si, Pd/Si, and Cr/Si systems. The markers were initially imbedded inside silicides and backscattering spectrometry was used to determine the marker displacement after different processing conditions. The results obtained in thermal annealing are quite consistent with that found in previous investigations. Ni is the dominant diffusing species in Ni_2Si, while Si is the diffusing species in CrSi_2. In Pd_2Si, both Pd and Si are moving species with Pd the faster of the two. In contrast, in growth of silicides by ion irradiation Si is the faster diffusing species in all three systems.

412

Marker experiments in growth studies of Ni/sub 2/Si, Pd/sub 2/Si, and CrSi/sub 2/ formed both by thermal annealing and by ion mixing  

Energy Technology Data Exchange (ETDEWEB)

Inert markers (evaporated tungsten and silver) were used in growth studies of silicides formed both by thermal annealing and by ion mixing in the Ni/Si, Pd/Si, and Cr/Si systems. The markers were initially imbedded inside silicides and backscattering spectrometry was used to determine the marker displacement after different processing conditions. The results obtained in thermal annealing are quite consistent with that found in previous investigations. Ni is the dominant diffusing species in Ni/sub 2/Si, while Si is the diffusing species in CrSi/sub 2/. In Pd/sub 2/Si, both Pd and Si are moving species with Pd the faster of the two. In contrast, in growth of silicides by ion irradiation Si is the faster diffusing species in all three systems.

1985-08-15

413

Magnetocaloric and magnetoresistance studies of GdPd{sub 2}Si  

Energy Technology Data Exchange (ETDEWEB)

The compound GdPd{sub 2}Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition strongly influences the magnetocaloric effect and magnetoresistance, which is large in this compound. (author). ...

2001-01-22

414

Magnetocaloric and magnetoresistance studies of GdPd_2Si  

International Nuclear Information System (INIS)

The compound GdPd_2Si, which is reported to order antiferromagnetically at 13 K, has been investigated by heat capacity and electrical resistivity measurement in the presence of external magnetic fields. In contrast to an earlier report, the zero-field heat capacity and resistivity data indicate two magnetic transitions at 13 and 17 K. The external magnetic field substantially influences the resistivity and heat capacity of the compound around the magnetic ordering temperature. The magnetocaloric effect, which is calculated from in-field heat capacity data, is quite large around the magnetic transition temperature. The magnetoresistance is also large near the magnetic ordering temperature. The metamagnetic transition is observed for 10 kOe magnetic field both in magnetocaloric and in magnetoresistance data. The metamagnetic transition strongly influences the magnetocaloric effect and magnetoresistance, which is large in this compound. (author). Letter-to-the-editor

2001-01-22

415

MRI findings of the brain in high-voltage electrical burn patient: case report  

Energy Technology Data Exchange (ETDEWEB)

We report the delayed sequelae arising in a case of electrical injury, reviewing the literature on the subject and focusing on the MRI findings of the brain. A 23-year-old male suffered burns to the left parietal scalp, both feet, and the anterior chest wall. Neurological symptoms and MRI abnormalities appeared 14 days after the insult and continued for about three months. T1-weight MR images demonstrated homogeneous hypointensity, while T2-weighted images depicted hyperintense finger-like projections. Contrast-enhanced T1-weighted images demonstrated strong band-like enhancement, indicating meningeal hyperemia. Follow-up MR imaging showed that the lesion had disappeared, indicating that the cerebral edema and meaningeal hyperemia were reversible.

2003-05-01

416

Loyal but ignored: The benefits and costs of constructive communication behavior  

British Library Electronic Table of Contents (United Kingdom)

The consequences of exit, voice, loyalty, and neglect behavior were examined using retrospective questionnaires (Study 1) and 2 social interaction diary studies (Study 2). Exit and neglect were generally associated with more negative partner responses and reduced feelings of value and closeness, and were reported to be more harmful to the relationship. Voice was associated with more positive partner responses and greater value and intimacy, and was perceived to be most beneficial to the relationship. In contrast, loyalty was perceived to have the same detrimental consequences as destructive behaviors (Study 1) and did not predict more positive outcomes within daily interactions (Study 2). These results indicate that, despite good intentions, loyal intimates are often left feeling ignored a...

2010-01-01

417

Local Ce environments and their effects on optical properties of SrS phosphors  

International Nuclear Information System (INIS)

In this study, we use electron paramagnetic resonance (EPR), optical absorption, and photoluminescence (PL) spectroscopies to determine the various Ce environments in SrS phosphor materials and how these affect absorption and emission properties. As the Ce concentration is increased from 450 to 7500 ppm, the total EPR-active Ce"3"+ and optical absorption signals increase linearly with Ce concentration; by contrast, the PL intensity saturates at fairly low Ce concentrations (1000 ppm Ce). We suggest that the nonlinear behavior of the PL arises from the presence of nonradiative deexcitation pathways such as defects associated with Ce sites, or Ce endash Ce pairs. copyright 1996 American Institute of Physics.

418

Limiting factors and landscape connectivity: the American marten in the Rocky Mountains  

British Library Electronic Table of Contents (United Kingdom)

In mobile animals, movement behavior can maximize fitness by optimizing access to critical resources and minimizing risk of predation. We sought to evaluate several hypotheses regarding the effects of landscape structure on American marten foraging path selection in a landscape experiencing forest perforation by patchcut logging. We hypothesized that in the uncut pre-treatment landscape marten would choose foraging paths to maximize access to cover types that support the highest density of prey. In contrast, in the post-treatment landscapes we hypothesized marten would choose paths primarily to avoid crossing openings, and that this would limit their ability to optimally select paths to maximize foraging success. Our limiting factor analysis shows that different resistant models may be sup...

2011-01-01

419

LMBFR and LWR in-core thermal-hydraulic codes: the state-of-the-art and research and development needs  

Energy Technology Data Exchange (ETDEWEB)

A review of analytical design methods used for predicting reactor core flow and temperature distributions is presented with emphasis on LMFBR's. The paper also briefly describes and contrasts the methods used for LWR's. These methods are global analysis, subchannel analysis, distributed parameter, and hybrid analysis. The evolution of the local and subchannel analysis methods is presented. Data used for code validation are also presented. Current research and development needs are identified and discussed. Areas identified for future research and development include methods and expermental data for analysis of distorted bundles and natural convection. Methods that have been developed for predicting the safety performance of LMFBR's and LWR's are not within the scope of this paper.

1981-04-01

420

Jump in the air gasification rate of potassium-doped cellulosic chars  

Energy Technology Data Exchange (ETDEWEB)

Chars prepared from potassium-exchanged carboxy methyl cellulose at several heat treatment temperatures (HTTs) were gasified in air isothermally at selected gasification temperatures (GTs) in the range 633-893 K to investigate the catalytic effectiveness of potassium species. The chars displayed a noticeable jump in gasification rate at a particular gasification temperature (called jump temperature, T{sub j}). The magnitude of jump was much less than that reported for copper and nickel catalysis, but comparable with that for calcium catalysis. Increase in HTT caused a decrease in the jump temperature of chars in contrast with the increase observed in copper, nickel and calcium catalysis; also the magnitude of jump did not decrease, but remained unaltered, on increasing HTT. The different behavior of potassium catalysis is correlated to a change in the chemical state of potassium at higher HTT. The results reveal the dependence of jump phenomenon on chemical state ...

2010-12-15

421

Is the 4.742 MeV state in "8"8Sr the 1"- two-phonon state?  

International Nuclear Information System (INIS)

A nuclear resonance fluorescence experiment on "8"8Sr has been performed with bremsstrahlung of 6.7 MeV endpoint energy. The #gamma#-ray linear polarisation has been measured with a EUROBALL CLUSTER detector used as a Compton polarimeter. The results indicate positive parity for the J=1 state at 4.742 MeV in "8"8Sr, in contrast to the previous interpretation as a 1"- two-phonon (2"+_1 x 3"-_1) state and in conflict with the predictions of the quasiparticle-phonon model. On the basis of such calculations the 1"+ state at 3.486 MeV may be considered as the 1"+_1 one-phonon state and the very strong 1"+_1#->#0"+_1 deexcitation as proton spin-flip 2p_1_/_2#->#2p_3_/_2 transition. (orig.)

2000-01-01

422

Iopentol in cardioangiography  

International Nuclear Information System (INIS)

Iopentol (350 mg I/ml) has been compared with iohixol (350 mg I/ml) in a double-blind randomized parallel group trial with 32 and 35 patients receiving iopentol and iohexol, respectively. Coronary angiography and left ventriculography were performed, and the mean total volume injected was 124 ml of iopentol and 135 ml of iohexol . There were no statistically significant differences regarding changes in heart rate and frequency of adverse advents, which were the primary parameters, between the two groups of patients. Blood pressure and ECG parameters revealed only minor fluctuations which were of no clinical relevance. The visualization of the coronary arteries and the left ventricle were the same with both contrast media, as was the diagnostic quality. The results support the use of iopentol in cardioangiography. (author). 1 ref.; 5 tabs.

423

Interlayer coupling between out-of-plane magnetized multilayers across a thin antiferromagnetic spacer  

British Library Electronic Table of Contents (United Kingdom)

The interlayer exchange coupling between Co/Pt perpendicular-to-plane magnetized layers across a thin IrMn spacer layer was experimentally studied. In contrast to earlier studies on interlayer coupling through antiferromagnetic NiO, which revealed an oscillatory coupling behavior as a function of NiO thickness, a ferromagnetic coupling was observed here in the range of IrMn thickness between 0.6 and 1.5nm and antiferromagnetic between 1.5 and 2.5nm. The antiferromagnetic coupling is attributed to an orange peel magnetostatic mechanism whereas the ferromagnetic coupling is attributed to an out-of-plane polarization of the antiferromagnetic IrMn layer induced by the interfacial exchange interaction with the adjacent out-of-plane ferromagnetic layers. Measurements of hysteresis loops versus t...

2011-01-01

424

Induction linac-driven free-electron lasers: Status and future prospects  

Energy Technology Data Exchange (ETDEWEB)

The high repetition rate and low single-pass gain inherent in an rf-driven Free Electron Laser (FEL) dictate that the laser system be configured as an oscillator. This allows the laser's electric field to build up over many passes around a high Q cavity. By way of contrast, the high-current capability of the Induction Linac (IL) system permits high single-pass optical gain, but the relatively low duty factor precludes oscillator operation; the pulses are neither long enough nor often enough to permit a field to accumulate in a cavity. The IL is thus configured as a MOPA (master oscillator/power amplifier) with a conventional laser serving as the MO. This report concentrates on the status of IL-driven FEL research at LLNL and gives a description of several applications for the high-peak-power radiation produced by an induction linac FEL.

1987-01-11

425

Incorporating phenolic compounds opens a new perspective to use zein films as flexible bioactive packaging materials  

British Library Electronic Table of Contents (United Kingdom)

To eliminate their classical brittleness and flexibility problems zein films were plasticized by incorporation of different phenolic acids (gallic acid (GA), p-hydroxy benzoic acid (HBA) or ferulic acids (FA)) or flavonoids (catechin (CAT), flavone (FLA) or quercetin (QU)). The use of GA, CAT, FA and HBA at 3 mg/cm2 eliminated the brittleness of films and gave highly flexible films showing elongations between 135% and 189%, while FLA and QU caused no considerable effect on film elongation. The films containing FA and HBA showed extreme swelling and lost their structural integrity when hydrated in distilled water. In contrast, CAT and GA containing films maintained their integrity following hydration. Most of the GA (up to 93%) and a considerable portion of CAT (up to 60%) in the films exis...

2011-01-01

426

Impact of Invasive Cane Toads on Australian Birds  

British Library Electronic Table of Contents (United Kingdom)

Abstract: The cane toad (Bufo marinus), a large, toxic, American anuran, was introduced to Australia in 1935. Populations of many of Australia's reptiles (snakes, varanid lizards, crocodiles) and carnivorous mammals (dasyurid marsupials) have declined because these predators are killed by the toad's powerful toxins. In contrast to these well-studied species, little is known about the cane toads impacts on Australian birds. We reviewed published and unpublished data on behavioral interactions between Australian avian predators and cane toads and collated distributional and dietary information to identify avian taxa potentially at risk from cane toad invasion. Cane toads are sympatric with 172 frog-eating bird species in Australia, and an additional 8 bird species overlap with the predicted ...

2009-01-01

427

High-visibilty two-photon interference at a telecom wavelength using picosecond regime separated sources  

CERN Document Server

We report on a two-photon interference experiment in a quantum relay configuration using two picosecond regime PPLN waveguide based sources emitting paired photons at 1550 nm. The results show that the picosecond regime associated with a guided-wave scheme should have important repercussions for quantum relay implementations in real conditions, essential for improving both the working distance and the efficiency of quantum cryptography and networking systems. In contrast to already reported regimes, namely femtosecond and CW, it allows achieving a 99% net visibility two-photon interference while maintaining a high effective photon pair rate using only standard telecom components and detectors.

2009-01-01

428

High-field magnetization of CeRh{sub 2}Si{sub 2} and CePd{sub 2}Si{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

High-field magnetization properties of single crystalline CeRh{sub 2}Si{sub 2} and CePd{sub 2}Si{sub 2} were investigated. Two-step metamagnetic transition (H{sub c1}=25.4 T and H{sub c2}=26.0 T) was observed in the case of CeRh{sub 2}Si{sub 2}, whereas no anomaly was found in the magnetization process of CePd{sub 2}Si{sub 2} up to 28 T. The mean field analysis has shown that CeRh{sub 2}Si{sub 2} is quite anisotropic compared to CePd{sub 2}Si{sub 2}, which results in the sharp contrast between the magnetization processes of the two compounds.

1998-07-01

429

High-field magnetization of CeRh_2Si_2 and CePd_2Si_2  

International Nuclear Information System (INIS)

High-field magnetization properties of single crystalline CeRh_2Si_2 and CePd_2Si_2 were investigated. Two-step metamagnetic transition (H_c_1=25.4 T and H_c_2=26.0 T) was observed in the case of CeRh_2Si_2, whereas no anomaly was found in the magnetization process of CePd_2Si_2 up to 28 T. The mean field analysis has shown that CeRh_2Si_2 is quite anisotropic compared to CePd_2Si_2, which results in the sharp contrast between the magnetization processes of the two compounds

1997-08-04

430

High voltage transmission lines studies with the use of artificial intelligence  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an alternative approach for the studies of high voltage transmission lines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmission lines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmission lines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and has an acceptable accuracy, constituting an additional tool of electric engineers. (author)

2009-12-15

431

High speed inverted optical-resolution photoacoustic microscopy  

Science.gov (United States)

Photoacoustic microscopy (PAM) offers label-free, optical absorption contrast. A high-speed, high-resolution PAM system in an inverted microscope configuration with a laser pulse repetition rate of 100,000 Hz and a stationary ultrasonic transducer was built. Four-dimensional in vivo imaging of microcirculation in mouse skin was achieved at 18 three-dimensional volumes per second with repeated two-dimensional raster scans of 100 by 50 points. The corresponding twodimensional B-scan (50 A-lines) frame rate was 1800 Hz, and the one-dimensional A-scan rate was 90,000 Hz. The lateral resolution is 0.23+/-0.03 ?m for Au nano-wire imaging, which is 2.0 times below the diffraction limit.

2011-02-01

432

Heterogeneity of the radiosensitivity and origins of tissue macrophage colony-forming cells  

Energy Technology Data Exchange (ETDEWEB)

Previous studies suggest that the radiosensitivity and origin of tissue macrophage precursors differ from those of hemopoietic macrophage colony-forming units (CFU-Ms) committed to macrophage-lineage cells. We assessed the origins of tissue macrophage colony-forming cells (M-CFCs) in mice by comparing their kinetics and radiosensitivities in the normal steady state and under the conditions of bone marrow depletion by [sup 89]Sr-administration and/or splenectomy. The results indicate that the radiosensitive peritoneal M-CFCs elicited by thioglycollate are derived from bone marrow macrophage precursors; where as alveolar M-CFCs, which are radioresistant, are self-sustained locally and independent of hemopoietic macrophage precursors. In contrast, highly radiosensitive liver M-CFCs are probably derived from CFU-Ms that appear to be propagated in the spleen in association with hemopoietic responses. (author).

1992-12-01

433

Geothermal Casimir Phenomena  

CERN Document Server

We present first worldline numerical results for the nontrivial interplay between geometry and temperature dependencies of the Casimir effect. We show that the temperature dependence of the Casimir force can be significantly larger for open geometries (e.g., perpendicular plates) than for closed geometries (e.g., parallel plates). For surface separations in the experimentally relevant range, the thermal correction for the perpendicular-plates configuration exhibits a stronger parameter dependence and exceeds that for parallel plates by more than an order of magnitude at room temperature. This effect can be attributed to the fact that the fluctuation spectrum for closed geometries is gapped, inhibiting the thermal excitation of modes at low temperatures. By contrast, open geometries support a thermal excitation of the low-lying modes in the gapless spectrum already at low temperatures.

2007-01-01

434

Generation and mobility of radon in soil. Technical report  

Energy Technology Data Exchange (ETDEWEB)

This study has confirmed large seasonal and daily variations of Rn in soil gas, developed models for the effects of temperature and moisture on air-water Rn partition, inhibited Rn diffusion from wet soil into sparse large air-filled pores and effects of diffusion into bedrock, demonstrated that organic matter is a major host for 226Ra in soils and that organic-bound Ra largely determines the proportion of 222Rn emanated to pore space, shown that in contrast 220Rn is emanated mainly from 224Ra in Fe-oxides, detected significant disequilibrium between 226Ra and 238U in organic matter and in some recent glacial soils, demonstrated by computer models that air convection driven by temperature differences is expected in moderately permeable soils on hillsides.

1993-05-01

435

Generation and mobility of radon in soil  

Energy Technology Data Exchange (ETDEWEB)

This study has confirmed large seasonal and daily variations of Rn in soil gas, developed models for the effects of temperature and moisture on air-water Rn partition, inhibited Rn diffusion from wet soil into sparse large air-filled pores and effects of diffusion into bedrock, demonstrated that organic matter is a major host for 226Ra in soils and that organic-bound Ra largely determines the proportion of 222Rn emanated to pore space, shown that in contrast 220Rn is emanated mainly from 224Ra in Fe-oxides, detected significant disequilibrium between 226Ra and 238U in organic matter and in some recent glacial soils, demonstrated by computer models that air convection driven by temperature differences is expected in moderately permeable soils on hillsides.

1993-01-01

436

Forecasting the growth of China’s natural gas consumption  

British Library Electronic Table of Contents (United Kingdom)

The use of natural gas in China is still relatively immature, as gas production only supplies a low percentage of the domestic energy system. In contrast, Chinese economy mainly relies on coal with a 67% share of the total primary energy supply. The environmental impact from this high coal dependence is significant and planners have sought for cleaner energy sources. Natural gas is both cleaner and generally more efficient than coal and gas consumption is rising quickly due to these facts. The growth tendency indicates that natural gas will become an important substitution for coal in some parts of the Chinese primary energy consumption. To quantify this tendency, this paper uses a system dynamics model to create a possible outlook. The results show that the gas consumption in China will c...

2011-01-01

437

Field-induced valence transition of Eu(Pd_1_-_xPt_x)_2Si_2  

International Nuclear Information System (INIS)

The magnetic susceptibility and high-field magnetization have been measured for the intermediate valence system Eu(Pd_1_-_xPt_x)_2Si_2 with 0#<=#x#<=#0.15. A first-order valence transition is observed for all the compounds under high field of 100 T at low temperatures. This valence transition is of first order accompanied with a large hysteresis, which is in contrast to a continuous valence change against temperature. Based on the interconfigurational fluctuation (ICF) model, the temperature- and field-induced valence transitions are discussed. It is found that a first-order valence transition can be induced by magnetic field, even if the system shows a continuous valence transition against temperature. Metamagnetic behavior at finite temperatures is also understood qualitatively by the ICF model. copyright 1997 The American Physical Society.

438

Fetal MRI of pathological brain development  

International Nuclear Information System (INIS)

Because of the superior tissue contrast, high spatial resolution, and multiplanar capabilities, fetal magnetic resonance imaging (MRI) can depict fetal brain pathologies with high accuracy. Pathological fetal brain development may result from malformations or acquired conditions. Differentiation of these etiologies is important with respect to managing the actual pregnancy or counseling future pregnancies. As a widened ventricular system is a common hallmark of both maldevelopment and acquired conditions, it may cause problems in the differential diagnosis. Fetal MRI can provide detailed morphological information, which allows refinement of the diagnosis of ventricular enlargement in a large number of cases. Systematic work-up of morphological details that may be recognized on MR images provides an approach for achieving a correct diagnosis in cases of ventricle enlargement. (orig.)

2006-02-01

439

Feeding ecology of mesopelagic zooplankton of the subtropical and subarctic North Pacific Ocean determined with fatty acid biomarkers  

British Library Electronic Table of Contents (United Kingdom)

Mesopelagic zooplankton may meet their nutritional and metabolic requirements in a number of ways including consumption of sinking particles, carnivory, and vertical migration. How these feeding modes change with depth or location, however, is poorly known. We analyzed fatty acid (FA) profiles to characterize zooplankton diet and large particle (>51?m) composition in the mesopelagic zone (base of euphotic zone ?1000m) at two contrasting time-series sites in the subarctic (station K2) and subtropical (station ALOHA) Pacific Ocean. Total FA concentration was 15.5 times higher in zooplankton tissue at K2, largely due to FA storage by seasonal vertical migrators such as Neocalanus and Eucalanus. FA biomarkers specific to herbivory implied a higher plant-derived food sou...

2010-01-01

440

Extraction methods of phase information for X-ray diffraction enhanced imaging  

Energy Technology Data Exchange (ETDEWEB)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.

2007-08-21

441

Extraction methods of phase information for X-ray diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is one of X-ray phase-contrast imaging methods, which is applied to inspect internal structures of weakly absorbing low-Z samples. The key problem of the DEI is how to extract phase information which is expressed by refraction-angle images from a series of DEI images measured in different positions of the rocking curve of the analyzer. Three effective extraction methods are presented in this paper: the statistical geometric-optics-approximation method, the maximum refraction-angle method and the Gaussian curve fitting method. They are compared with the existing methods, such as the D. Chapman's geometric optics approximation method and the multiple-images statistical method. A 2D computer simulation experiment is performed to draw comparisons of these methods. The experimental results prove that the above three methods have more precision of refraction-angle values than existing methods.

2007-08-21

442

Experimental evidence for intraplate deformation controlled by netlike plastic-flow in central-eastern Asia  

British Library Electronic Table of Contents (United Kingdom)

The experimental results of brittle/ductile two-layer analogue models verify that intraplate tectonic deformation in central-eastern Asia is controlled mainly by the netlike plastic-flow (NPF) occurring in the lower lithosphere, including the lower crust and lithospheric mantle. The ductile lower layer in the model, corresponding to the lower lithosphere in the natural prototype, is made of a mixture of gum rosin and turpentine oil and the brittle upper one, to the upper crust, is formed by the consolidation of talc-powder slurry. The NPF hypothesis for continental dynamics can be regarded as a combination and development of two kinds of seemingly mutually exclusive ones, which are based on the theories of slip-line field and viscous (plastic) flow, respectively. In contrast to "homogeneou...

2007-01-01

443

Experimental and analytical study of saturation current density of laser-doped phosphorus emitters for silicon solar cells  

British Library Electronic Table of Contents (United Kingdom)

Heavily doped emitters with low saturation current density are of particular interest for selective emitter solar cells. These emitters can be obtained by laser doping through the phosphosilicate glass layer formed after thermal diffusion from POCl3 gas. The experimental results show that in contrast to purely POCl3 furnace-diffused emitters, the saturation current density of laser-doped emitters does not increase linearly as sheet resistance decreases, but rather features two distinct regimes. In one of these regimes, the saturation current density is found to decrease as the sheet resistance decreases, reaching values lower than those of furnace emitters. This peculiar behaviour was explained by both qualitative analysis and numerical simulations.

2011-01-01

444

Evaluation of soil moisture derived from passive microwave remote sensing over agricultural sites in Canada using ground-based soil moisture monitoring networks  

British Library Electronic Table of Contents (United Kingdom)

Passive microwave soil moisture datasets can be used as an input to provide an integrated assessment of climate variability as it relates to agricultural production. The objective of this research was to examine three passive microwave derived soil moisture datasets over multiple growing seasons in contrasting Canadian agricultural environments. Absolute and relative soil moisture was evaluated from two globally available datasets from the Advanced Microwave Scanning Radiometer for EOS (AMSR-E) sensor using different retrieval algorithms, as well as relative soil wetness at a weekly scale from the Special Sensor Microwave/Imager (SSM/I) sensor. At a daily scale, the Land Parameter Retrieval Model (LPRM) provides a better estimate of surface soil moisture conditions than the National Snow a...

2010-01-01

445

Equivalence Checking in Embedded Systems Design Verification  

CERN Document Server

In this report we focus on some aspects related to modeling and formal verification of embedded systems. Many models have been proposed to represent embedded systems . These models encompass a broad range of styles, characteristics, and application domains and include the extensions of finite state machines, data flow graphs, communication processes and Petri nets. In this report, we have used a PRES+ model (Petri net based Representation for Embedded Systems) as an extension of classical Petri net model that captures concurrency, timing behaviour of embedded systems; it allows systems to be representative in different levels of abstraction and improves expressiveness by allowing the token to carry information. Modeling using PRES+, as discussed above, may be convenient for specifying the input behaviour because it supports concurrency. However, there is no equivalence checking method reported in the literature for PRES+ models to the best of our knowledge. In ...

2010-01-01

446

Effects of simulated acidic rain applied alone and in combination with ambient rain on growth and yield of field-grown snap bean  

Energy Technology Data Exchange (ETDEWEB)

Field-grown snap bean plants were treated with simulated acidic rain applied either alone or in combination with ambient rain and the effects on growth and yield were determined. In plots where ambient rain was excluded, a retractable canopy was activated to shield the crop. Four levels of acidity at pH values of 5.0, 4.2, 3.4 and 2.6 were applied in four replicate treatments and the experiment was conducted in two successive years (1981 and 1982). In plots that received only simulated rain, yield was not adversely affected by acidic rain; in 1981, a positive linear relationship was present between acidity of simulated rain and yield, but in 1981, no effect was found. In contrast, in plots that received both simulated and ambient rain, a negative linear relationship between acidity in simulated rain and yield was observed in both years.

1984-01-01

447

Effects of dietary glucosylceramide on dermatitis in atopic dermatitis model mice  

British Library Electronic Table of Contents (United Kingdom)

The effects of dietary plant and yeast cerebroside (glucosylceramide), a major sphingolipid in plants and yeast, on atopic dermatitis (AD) like symptoms were investigated in a mouse model. After 7 wk of feeding with a diet containing maize glucosylceramide, plasma IgE levels became significantly lower and in contrast, the levels of interleukin (IL)-12, which induces cellular immunity, became significantly higher in the AD mice than in the controls. However, the sphingolipid constituents of the skin fraction in the maize glucosylceramide fed group did not contain sphingoid bases of plant origin, such as 8-unsaturated sphingoid bases. The results of the present study indicated that dietary plant glucosylceramide prevented AD-like symptoms in AD model mice via regulation of Th1/Th2 balance. P...

2010-01-01

448

Effects of burrow condition and seed handling time on hoarding strategies of Edward's long-tailed rat (Leopoldamys edwardsi)  

British Library Electronic Table of Contents (United Kingdom)

Many hoarding rodents use burrows not only for dwelling and protection from natural enemies, but also for food storage. However, little is known how burrows used by scatter-hoarding animals influence their foraging behaviors. In addition, handling time for a given food item has a fundamental impact on hoarding strategies of these hoarding animals: food items with longer handling time are more likely to be hoarded due to increasing predation risk because the animals spend more time outside their burrows if they consumed such food. By providing with two types of artificial burrows (aboveground vs. underground) and two types of food items (i.e. seeds) with contrasting handling times, we investigated how burrow condition and handling time co-influence hoarding strategies of a key scatter-hoard...

2010-01-01

449

Effective Population Size Is Positively Correlated with Levels of Adaptive Divergence among Annual Sunflowers  

British Library Electronic Table of Contents (United Kingdom)

The role of adaptation in the divergence of lineages has long been a central question in evolutionary biology, and as multilocus sequence data sets have become available for a wide range of taxa, empirical estimates of levels of adaptive molecular evolution are increasingly common. Estimates vary widely among taxa, with high levels of adaptive evolution in Drosophila, bacteria, and viruses but very little evidence of widespread adaptive evolution in hominids. Although estimates in plants are more limited, some recent work has suggested that rates of adaptive evolution in a range of plant taxa are surprisingly low and that there is little association between adaptive evolution and effective population size in contrast to patterns seen in other taxa. Here, we analyze data from 35 loci for si...

2011-01-01

450

Effect of pressure on the valence state of Yb in YbPd_2Si_2  

International Nuclear Information System (INIS)

The intermediate valent behaviour of YbPd_2Si_2 has been studied under pressure in the temperature range from 1.2 K to 90 K by using the 84 keV Moessbauer transition in "1"7"0Yb. At 54 kbar and 4.2 K we obtain an increase of the electric field gradient (EFG) by a factor of #approx =# 3. In addition, the EFG varies strongly with temperature, in contrast to the behaviour at ambient pressure. At 1.2 K a change of the hyperfine pattern is observed indicating a magnetic character of the Yb ion. These results provide evidence of a pressure induced change of the valence state close to 3+. (orig.).

451

Drug delivery with upconversion nanoparticles for multi-functional targeted cancer cell imaging and therapy  

British Library Electronic Table of Contents (United Kingdom)

Upconversion nanoparticles (UCNPs) with unique multi-photon excitation photoluminescence properties have recently been intensively explored as novel contrast agents for low-backgroundbiomedical imaging. In this work, we functionalize UCNPs with a polyethylene glycol (PEG) grafted amphiphilic polymer. The PEGylated UCNPs are loaded with a commonly used chemotherapy molecule, doxorubicin (DOX), by simple physical adsorption via a supramolecular chemistry approach for intracellular drug delivery. The loading and releasing of DOX from UCNPs are controlled by varying pH, with an increased drug dissociation rate in acidic environment, favorable for controlled drug release. Upconversion luminescence (UCL) imaging by a modified laser scanning confocal microscope reveals the time course of intracel...

2011-01-01

452

Do Thinning and Burning Sites Revegetated after Bauxite Mining Improve Habitat for Terrestrial Vertebrates?  

British Library Electronic Table of Contents (United Kingdom)

Thinning and burning forests established on revegetated mine pits in jarrah (Eucalyptus marginata) forests of south-west Australia is being considered as a management option to accelerate succession in sites with excessive tree densities. To assess the impact of thinning and burning on reptiles and small mammals, we installed trapping grids in eight thinned and burned sites, each paired with untreated controls. Of the eight pairs, four were in rehabilitated sites (planted with nonlocal species) and four were in restored sites (seeded with local species). Thinning and burning had no significant impact on the small mammal community, although Cercatetus concinnus was more abundant in rehabilitated sites. In contrast, thinning and burning significantly increased reptile abundance and species r...

2010-01-01

453

Disturbance-mediated competition between perennial plants along a resource supply gradient  

British Library Electronic Table of Contents (United Kingdom)

Summary 1.-Traditional views of ecological disturbance emphasize the role that physical disturbances play in reducing competition between populations and maintaining species coexistence. I present an alternative view that employs a simple Lotka-Volterra model to demonstrate how disturbance resistance, disturbance resilience and resource storage can increase competition between individual perennial plants of similar growth form along a resource supply gradient. 2.-In contrasting the growth of individual genets of two hypothetical species, I assumed that traits associated with inherently low module (i.e. plant part) mortality in infertile soils resulted in greater resource storage, but traded off with maximum potential net photosynthesis rates and thus disturbance resilience. 3.-The species ...

2011-01-01

454

Distinguishing local from global climate influences in the variation of carbon status with altitude in a tree line species  

British Library Electronic Table of Contents (United Kingdom)

Abstract Aim- Two alternative hypotheses attempt to explain the upper elevation limit of tree lines world-wide, the carbon-limitation hypothesis (CLH) and the growth-limitation hypothesis (GLH); the altitudinal decrease of temperature is considered the driver constraining either carbon gain or growth. Using a widely distributed tree line species (Nothofagus pumilio) we tested whether tree line altitude is explained by the CLH or the GLH, distinguishing local from global effects. We elaborated expectations based on most probable trends of carbon charging with altitude according to both hypotheses, considering the alternative effects of drought. Location- Two climatically contrasting tree line ecotones in the southern Andes of Chile: Mediterranean (3654- S) and Patagonia (4604- S). Methods- ...

2011-01-01

455

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

Energy Technology Data Exchange (ETDEWEB)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-12-01

456

Digital radiography of pulmonary abnormalities using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Fuji computed radiography (FCR) utilizing imaging plates stimulated by a scanning lazer has been developed in Japan and come to be widely available in diagnostic radiology. This system is advantageous because many processed images can be obtained with a single exposure. However, no reports have been published on the exact conditions necessary under which the FCR image processing method will produce improved visibility of pulmonary abnormal shadows on chest radiographs. In this report, chest FCR images obtained from 50 patients were analyzed, and the best practical image processing conditions were determined for each pathological state. Fundamental analysis was also performed for spatial and contrast resolution with FUNK chart and Burger's phantom using various thickness of acryl plate. Ninety processing images per exposure were analyzed, and the best practical conditions were determined. (author).

1991-01-01

457

Differential responses of the freshwater wetland species Juncus effusus L. and Caltha palustris L. to iron supply in sulfidic environments  

British Library Electronic Table of Contents (United Kingdom)

Sulfur pollution can lead to serious problems in freshwater wetlands, including phosphorus eutrophication and sulfide toxicity. We tested the effects of anaerobic iron-rich groundwater discharge in fens, simulated by iron injection, on two characteristic species (Juncus effusus and Caltha palustris) in a sulfidic environment. Biomass production of C. palustris roots showed an optimum response to the combined addition of iron and sulfide, with highest values at intermediate concentrations of both substances. Iron deficiency apparently occurred at low iron concentrations, while at high iron concentrations, growth was decreased. For J. effusus, in contrast, no toxic effects were found of both iron and sulfide. This could be explained by larger radial oxygen loss (ROL) of J. effusus and could ...

2007-01-01

458

Differential responses of populations of the copepod Acartia hudsonica to toxic and nutritionally insufficient food algae  

British Library Electronic Table of Contents (United Kingdom)

Nutritional insufficiency and toxicity are deleterious effects of phytoplankton on grazers. We hypothesize that toxic food is likely to have stronger evolutionary selective effects on grazers than nutritionally insufficient food. We explore this hypothesis in comparative studies of egg production and egg hatching of the copepod Acartia hudsonica challenged with both a toxic and a nutritionally insufficient alga. Experiments lasting 6 days, in which mixtures of different proportions of the suspect and a control alga were offered as food to female copepods, showed that the dinoflagellate Alexandrium fundyense, which bears paralytic shellfish toxins, was toxic to A. hudsonica. In contrast, the diatom Phaeodactylum tricornutum was nutritionally insufficient to A. hudsonica. In another set of e...

2011-01-01

459

Differential facilitative and competitive effects of a dominant macrophyte in grazed subtropical wetlands  

British Library Electronic Table of Contents (United Kingdom)

Summary 1.-Plant-plant interactions fluctuate between competition and facilitation depending upon ecological conditions and species traits. Facilitative interactions are expected to increase in frequency via associational defences with increasing consumer pressure. The ability of species to cope with competition and/or ecological stressors may alter the outcome of plant-plant interactions. 2.-We conducted a transplant experiment to determine if native and non-native grasses and forbs respond similarly to interactions with Juncus effusus L., an unpalatable benefactor species, along a grazing intensity gradient in two contrasting pasture types: intensively managed and semi-natural. We expected competitive taller, erect species (grasses) and non-natives to obtain stronger facilitative effects...

2011-01-01

460

Differential Performance of a Specialist and Two Generalist Herbivores and Their Parasitoids on Plantago lanceolata  

British Library Electronic Table of Contents (United Kingdom)

The ability to cope with plant defense chemicals differs between specialist and generalist species. In this study, we examined the effects of the concentration of the two main iridoid glycosides (IGs) in Plantago lanceolata, aucubin and catalpol, on the performance of a specialist and two generalist herbivores and their respective endoparasitoids. Development of the specialist herbivore Melitaea cinxia was unaffected by the total leaf IG concentration in its host plant. By contrast, the generalist herbivores Spodoptera exigua and Chrysodeixis chalcites showed delayed larval and pupal development on plant genotypes with high leaf IG concentrations, respectively. This result is in line with the idea that specialist herbivores are better adapted to allelochemicals in host plants on which they...

2011-01-01

461

Different tolerances and responses to low temperature and darkness between waterbloom forming cyanobacterium Microcystis and a green alga Scenedesmus  

British Library Electronic Table of Contents (United Kingdom)

The dynamics of planktonic cyanobacteria in eutrophicated freshwaters play an important role in formation of annual summer blooms, yet overwintering mechanisms of these water bloom forming cyanobacteria remain unknown. The responses to darkness and low temperature of three strains (unicellular Microcystis aeruginosa FACHB-905, colonial M.?aeruginosa FACHB-938, and a green alga Scenedesmus quadricauda FACHB-45) were investigated in the present study. After a 30-day incubation under darkness and low temperature, cell morphology, cell numbers, chlorophyll a, photosynthetic activity (ETRmax and I k), and malodialdehyde (MDA) content exhibited significant changes in Scenedesmus. In contrast, Microcystis aeruginosa cells did not change markedly in morphology, chlorophyll a, photosynthetic activi...

2008-01-01

462

Detached divertor plasmas in JET  

Energy Technology Data Exchange (ETDEWEB)

In simulations with high radiated power fractions, it is possible to produce the drop in ion current to the divertor targets typical of detached plasmas. Despite the fact that these experiments are performed on beryllium target tiles, radiation from deuterium and beryllium cannot account for the measured power losses. The neutral deuterium levels in the SOL in these plasmas are higher than the model predicts. This may be due to leakage from the divertor or to additional wall sources related to the non-steady nature of these plasmas. In contrast, a surprisingly high level of carbon is present in these discharges; higher even than would be predicted are the divertor target tiles pure carbon. This level may well be large enough to produce the measured radiation. (authors). 6 refs., 2 figs., 1 tab.

1994-07-01

463

Density separation of combustion-derived soot and petrogenic graphitic black carbon: Quantification and isotopic characterization  

Energy Technology Data Exchange (ETDEWEB)

The black carbon continuum is composed of a series of carbon-rich components derived from combustion or metamorphism and characterized by contrasting environmental behavior and susceptibility to oxidation. In this work, we present a micro-scale density fractionation method that allows isolating the small quantities of soot-like and graphitic material usually found in natural samples. Organic carbon and {delta}{sup 13}C mass balance calculations were used to quantify the relative contributions of the two fractions to thermally-stable organic matter from a series of aquatic sediments. Varying proportions of soot-like and graphitic material were found in these samples, with large variations in {delta}{sup 13}C signatures suggesting important differences in their origin and/or dynamics in the environment.

2009-01-01

464

DFT study of structure?properties correlations in [MnTPP][TCNE] quasi-one-dimensional molecular magnets  

British Library Electronic Table of Contents (United Kingdom)

We report the first band structure calculations of the quasi-one-dimensional [MnTPP][TCNE] compounds (TPP?=?meso-tetraphenylporphyrinato, TCNE?=?tetracyanoethylene), based on Density Functional Theory (DFT) methods, in order to interpret the magnetic ordering in these prototypic systems. We compare and contrast the results of broken-symmetry DFT calculations for extended systems, with periodic boundary conditions, and for finite systems, magnetic dimers modeling the actual molecular magnets. By varying systematically the main angles, we are able to determine the geometry dependence of the exchange interaction. Structure?properties correlations in these charge-transfer salts reveal the determinant role of the Mn-(N?C)TCNE bond angle on the strength of the ferrimagnetic coupling between the ...

2011-01-01

465

Cyclic Spectral Analysis of Radio Pulsars  

CERN Document Server

Cyclic spectral analysis is a signal processing technique designed to deal with stochastic signals whose statistics vary periodically with time. Pulsar radio emission is a textbook example of this signal class, known as cyclostationary signals. In this paper, we discuss the application of cyclic spectral analysis methods to pulsar data, and compare the results with the traditional filterbank approaches used for almost all pulsar observations to date. In contrast to standard methods, the cyclic spectrum preserves phase information of the radio signal. This feature allows us to determine the impulse response of the interstellar medium and the intrinsic, unscattered pulse profile directly from a single observation. We illustrate these new analysis techniques using real data from an observation of the millisecond pulsar B1937+21.

2011-01-01

466

Cross-count identity, distinctness, and the theory of internal and external relations  

British Library Electronic Table of Contents (United Kingdom)

Baxter (Australas J Philos 79:449?464, 2001) proposes an ingenious solution to the problem of instantiation based on his theory of cross-count identity. His idea is that where a particular instantiates a universal it shares an aspect with that universal. Both the particular and the universal are numerically identical with the shared aspect in different counts. Although Baxter does not say exactly what a count is, it appears that he takes ways of counting as mysterious primitives against which different numerical identities are defined. In contrast, I defend the idea?suggested, though not quite endorsed, by Baxter himself?that counts are independent dimensions of numerical identity. Different ways of counting are explained by the existence of these different sorts of identity (i.e., counts)...

2010-01-01

467

Corrosion resistance of tungsten and molybdenum alloys with #approx# 30 at.% Re in nitrogen- and oxygen-containing environments  

International Nuclear Information System (INIS)

Formation kinetics and composition of products of interaction of binary and ternary tungsten-molybdenum-rhenium alloys containing 30#+-#3 at.% (27-47 weight %) Re with products of thermal dissociation of ammonia and nitrogen-oxygeneous mixtures are studied. Mo-45% Re-10%W ternary alloy occupies intermediate position between W-27%Re and Mo-47%Re binary alloys, while its corrosion resistance and corrosion nature are close to those of W-Re and mechanical features - to those of Mo-Re alloy. It is explained by the fact, that the variation of W and Mo ration occurs in thin surface layer of ternary alloys in contrast to the initial state and the enrichment of near-the-surface layer with tungsten occurs under hot and cold deformation, at aging in the air, and during oxidation-reduction treatment. 4 refs.; 7 figs.

468

Continuous Paranematic-to-Nematic Ordering Transitions of Liquid Crystals in Tubular Silica Nanochannels  

CERN Document Server

The optical birefringence of rod-like nematogens (7CB, 8CB), imbibed in parallel silica channels with 10 nm diameter and 300 micrometer length, is measured and compared to the thermotropic bulk behavior. The orientational order of the confined liquid crystals, quantified by the uniaxial nematic ordering parameter, evolves continuously between paranematic and nematic states, in contrast to the discontinuous isotropic-to-nematic bulk phase transitions. A Landau-de Gennes model reveals that the strength of the orientational ordering fields, imposed by the silica walls, is beyond a critical threshold, that separates discontinuous from continuous paranematic-to-nematic behavior. Quenched disorder effects, attributable to wall irregularities, leave the transition temperatures affected only marginally, despite the strong ordering fields in the channels.

2008-01-01

469

Conservation laws. Generation of physical fields. Principles of field theories  

CERN Document Server

In the paper the role of conservation laws in evolutionary processes, which proceed in material systems (in material media) and lead to generation of physical fields, is shown using skew-symmetric differential forms. In present paper the skew-symmetric differential forms on deforming (nondifferentiable) manifolds were used in addition to exterior forms, which have differentiable manifolds as a basis. Such skew-symmetric forms (which were named evolutionary ones since they possess evolutionary properties), as well as the closed exterior forms, describe the conservation laws. But in contrast to exterior forms, which describe conservation laws for physical fields, the evolutionary forms correspond to conservation laws for material systems. The evolutionary forms possess an unique peculiarity, namely, the closed exterior forms are obtained from these forms. It is just this that enables one to describe the process of generation of physical fields, to disclose connection ...

2007-01-01

470

Conjugation is essential for the anticholestatic effect of NorUrsodeoxycholic acid in taurolithocholic acid induced cholestasis in rat liver  

British Library Electronic Table of Contents (United Kingdom)

Abstract NorUDCA (24 norursodeoxycholic acid), the C23 homolog of ursodeoxycholic acid (UDCA), showed remarkable therapeutic effects in cholestatic Mdr2 (Abcb4) (multidrug resistance protein 2/ATP binding cassette b4) knockout mice with sclerosing/fibrosing cholangitis. In contrast to UDCA, norUDCA is inefficiently conjugated in human and rodent liver, and conjugation has been discussed as a key step for the anticholestatic action of UDCA in cholestasis. We compared the choleretic, anticholestatic, and antiapoptotic properties of unconjugated and taurine conjugated UDCA (C24) and norUDCA (C23) in isolated perfused rat liver (IPRL) and in natrium/taurocholate cotransporting polypeptide (Ntcp) transfected human hepatoma (HepG2) cells. Taurolithocholic acid (TLCA) was used to induce a predomi...

2010-01-01

471

Comparison of skeletal and bone marrow radionuclide scintimetry of femoral neck fracture  

Energy Technology Data Exchange (ETDEWEB)

Twenty-six patients with late complications following femoral neck fracture were examined with both skeletal and bone marrow radionuclide scintimetry. There was no correlation between the methods with respect to the quantitative assessment of femoral head vascularity based on different uptake ratios comparing the fractured and the intact side. Skeletal scintimetry always had good image quality and permitted reliable differentation between nonunion of the fracture and late segmental collapse, in contrast to bone marrow scintimetry which gave poor image quality. Skeletal scintimetry thus seems superior to bone marrow scintimetry for assessment and differential diagnosis of late complications following femoral neck fracture. It is emphasized that the physiological mechanisms for radionuclide uptake must be taken into account when comparing scintimetric studies using different tracers.

1984-01-01

472

Comparison of skeletal and bone marrow radionuclide scintimetry of femoral neck fracture  

International Nuclear Information System (INIS)

Twenty-six patients with late complications following femoral neck fracture were examined with both skeletal and bone marrow radionuclide scintimetry. There was no correlation between the methods with respect to the quantitative assessment of femoral head vascularity based on different uptake ratios comparing the fractured and the intact side. Skeletal scintimetry always had good image quality and permitted reliable differentation between nonunion of the fracture and late segmental collapse, in contrast to bone marrow scintimetry which gave poor image quality. Skeletal scintimetry thus seems superior to bone marrow scintimetry for assessment and differential diagnosis of late complications following femoral neck fracture. It is emphasized that the physiological mechanisms for radionuclide uptake must be taken into account when comparing scintimetric studies using different tracers. (author).

473

Clinical evaluations of intra-arterial subtraction angiography using Fuji computed radiography  

International Nuclear Information System (INIS)

Intra-arterial subtraction angiography(IADSA) using Fuji computed radiography(FCR) was performed on 130 patients with cervical, pelvic, peripheral and abdominal diseases. It was compared with conventional angiography(radiographs produced by combining photographic film with an intensifying screen) performed on same patients. Radiographs produced by FCR were better than conventional radiographs in cervical, pelvic and peripheral angiography. In the abdominal angiography using FCR, there was misregistration artifact in some cases, but in hepatic angiography, the new radiographs under the injection of small amount of contrast medium(about 10ml) and the short exposure duration(about 10 seconds) were excellent. It was as valuable as conventional angiography (infusion hepatic angiography) for diagnosing hepatic neoplasms. (author).

1985-01-01

474

Cancer-cell-specific cytotoxicity of non-oxidized iron elements in iron core-gold shell NPs  

British Library Electronic Table of Contents (United Kingdom)

Gold-coated iron nanoparticles (NPs) selectively and significantly (P <0.0001) inhibit proliferation of oral- and colorectal-cancer cells in vitro at doses as low as 5 mg/mL, but have little adverse effect on normal healthy control cells. The particle treatment caused delay in cell-cycle progression, especially in the S-phase. There was no significant difference in the NP uptake between cancer and control cells, and cytotoxicity resulted primarily from the iron core, before oxidation, rather than from the Fe ions released from the core. In contrast with magnetic NPs that usually serve as drug carriers, diagnostic probes or hyperthermia media, the iron, before oxidation, in the NPs selectively suppressed cancer cell growth and left healthy control cells unaffected in vitro and in vivo. This...

2011-01-01

475

Brine injection studies at Lawrence Berkeley Laboratory  

Energy Technology Data Exchange (ETDEWEB)

As an integral part of DOE/GTD's Brine Injection Program, LBL is developing and demonstrating methods for: (1) designing and analyzing injection tests, (2) predicting and monitoring migration of injected fluids, and (3) optimizing field-wide injection and heat extraction operations in geothermal reservoirs. Computational and well test techniques are being developed (a) to detect and predict the movement of fluids of contrasting temperatures, phase compositions and chemistries in the injected formation, and (b) to characterize the associated physical and chemical processes occurring in the reservoir. LBL's theoretical and field-related brine injection activities in FY 1986 are described, and progress made during FY 1987 is discussed.

1987-01-01

476

Branching in Amyloid Fibril Growth  

British Library Electronic Table of Contents (United Kingdom)

Using the peptide hormone glucagon and Ab(1-40) as model systems, we have sought to elucidate the mechanisms by which fibrils grow and multiply. We here present real-time observations of growing fibrils at a single-fibril level. Growing from preformed seeds, glucagon fibrils were able to generate new fibril ends by continuously branching into new fibrils. To our knowledge, this is the first time amyloid fibril branching has been observed in real-time. Glucagon fibrils formed by branching always grew in the forward direction of the parent fibril with a preferred angle of 35-40degree. Furthermore, branching never occurred at the tip of the parent fibril. In contrast, in a previous study by some of us, Ab(1-40) fibrils grew exclusively by elongation of preformed seeds. Fibrillation kinetics i...

2009-01-01

477

Benign lymphoepithelial lesion of the parotid gland in AIDS patients: CT characteristics  

International Nuclear Information System (INIS)

Contrast agent-enhanced CT scans in nine male patients with histologically proved benign lymphoepithelial lesions of the perotid gland were reviewed. All scans showed cystic-appearing masses with peripheral rim enhancement corresponding to the macroscopic appearance of the lesion. Five patients were seropositive for human immunodeficiency virus (HIV) infection or had infections seen in acquired immunodeficiency syndrome. Three patients were members of high-risk groups. Only one patient had symptoms of the SICCA syndrome. Once a rare cause of parotid gland enlargement, benign lymphoepithelial lesions have recently been seen with increasing frequency in patients with HIV infection. Although the CT appearance is not pathognomic, correlation results of aspiration cytology and with clinical history can lead to a preoperative diagnosis of a benign lymphoepithelial lesion.

478

Avian gut-passage effects on seed germination of shrubland species in Mediterranean central Chile  

British Library Electronic Table of Contents (United Kingdom)

Effects of avian gut-passage on seed germination are important to assess the effectiveness of frugivores in woodland regeneration, particularly in biodiversity hotspots that have a high incidence of avian frugivory. We examined the effect of avian gut-passage on seed germination in contrast to seeds that remain uneaten in five shrub species in Mediterranean central Chile and sought to determine the physiological mechanism(s) by which seed germinability is modified. Germination assays were conducted in a glasshouse for five common shrub species of the sub-Andean matorral: Azara dentata (Flacourtiaceae), Schinus polygamus and Schinus molle (Anacardiaceae), Cestrum parqui (Solanaceae), and Maytenus boaria (Celastraceae). We estimated germinability (final percent germination), dormancy length ...

2011-01-01

479

Automated motion estimation of root responses to sucrose in two Arabidopsis thaliana genotypes using confocal microscopy  

British Library Electronic Table of Contents (United Kingdom)

Root growth is a highly dynamic process influenced by genetic background and environment. This paper reports the development of R scripts that enable root growth kinematic analysis that complements a new motion analysis tool: PlantVis. Root growth of Arabidopsis thaliana expressing a plasma membrane targeted GFP (C24 and Columbia 35S:LTI6b-EGFP) was imaged using time-lapse confocal laser scanning microscopy. Displacement of individual pixels in the time-lapse sequences was estimated automatically by PlantVis, producing dense motion vector fields. R scripts were developed to extract kinematic growth parameters and report displacement to ?0.1 pixel. In contrast to other currently available tools, Plantvis-R delivered root velocity profiles without interpolation or averaging across the root s...

2011-01-01

480

Atmospheric 222Rn measurements at San Nicolas Island during 1980. Memorandum report  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements in the near surface air at San Nicolas Island, California, are presented for five different measurement sessions between May 1978 and July 1980. Emphasis is on the previously unreported results for January and July 1980. For six of eight days during the January session the measured radon concentration was greater than 40 picocuries per cm, corresponding to a continental air mass. Only the first day involved a maritime air mass with radon concentration less than about 6 picocuries per cm. In contrast to all the previous sessions, maritime air dominated the ten day session in July 1980, with radon concentrations generally less than about 5 picocuries per cm.

1981-10-13

481

Approximate MIMO Iterative Processing with Adjustable Complexity Requirements  

CERN Document Server

Targeting always the best achievable bit error rate (BER) performance in iterative receivers operating over multiple-input multiple-output (MIMO) channels may result in significant waste of resources, especially when the achievable BER is orders of magnitude better than the target performance (e.g., under good channel conditions and at high signal-to-noise ratio (SNR)). In contrast to the typical iterative schemes, a practical iterative decoding framework that approximates the soft-information exchange is proposed which allows reduced complexity sphere and channel decoding, adjustable to the transmission conditions and the required bit error rate. With the proposed approximate soft information exchange the performance of the exact soft information can still be reached with significant complexity gains.

2011-01-01

482

Analysis of work-environment data from three army field stations  

Energy Technology Data Exchange (ETDEWEB)

Data from a detailed evaluation of environment conditions in three U.S. Army field stations are presented. Three field stations were evaluated: Kunia, Augsburg, and Berlin. Results from a questionnaire administered to over 600 people at all sites in three job types (operator, analyst, and administrative/other) are given which indicate major concerns with conditions such as temperature, lighting, space, furniture, equipment functioning, and general environmental quality. Physical data obtained from measurements of over 270 work stations indicated the presence of cold temperatures, low light levels, reduced VDT screen contrast, glare, and distracting noises. The report provides the basic data that support the concerns expressed by Headquarters; namely, that field-station personnel perform their jobs under conditions likely to impair their effectiveness. Suggestions for improving conditions are given in a companion report by Rubin and Collins.

1988-10-01

483

Acoustic cloaking in two dimensions: a feasible approach  

Energy Technology Data Exchange (ETDEWEB)

This work proposes an acoustic structure feasible to engineer that accomplishes the requirements of acoustic cloaking design recently introduced by Cummer and Schurig (2007 New J. Phys. 9 45). The structure, which consists of a multilayered composite made of two types of isotropic acoustic metamaterials, exactly matches the conditions for the acoustic cloaking. It is also shown that the isotropic metamaterials needed can be made of sonic crystals containing two types of material cylinders, whose elastic parameters should be properly chosen in order to satisfy (in the homogenization limit) the acoustic properties under request. In contrast to electromagnetic cloaking, the structure here proposed verifies the acoustic cloaking in a wide range of wavelengths; its performance is guaranteed for any wavelength above a certain cutoff defined by the homogenization limit of the sonic crystal employed in its fabrication.

2008-06-15

484

Acoustic cloaking in two dimensions: a feasible approach  

International Nuclear Information System (INIS)

This work proposes an acoustic structure feasible to engineer that accomplishes the requirements of acoustic cloaking design recently introduced by Cummer and Schurig (2007 New J. Phys. 9 45). The structure, which consists of a multilayered composite made of two types of isotropic acoustic metamaterials, exactly matches the conditions for the acoustic cloaking. It is also shown that the isotropic metamaterials needed can be made of sonic crystals containing two types of material cylinders, whose elastic parameters should be properly chosen in order to satisfy (in the homogenization limit) the acoustic properties under request. In contrast to electromagnetic cloaking, the structure here proposed verifies the acoustic cloaking in a wide range of wavelengths; its performance is guaranteed for any wavelength above a certain cutoff defined by the homogenization limit of the sonic crystal employed in its fabrication.

2008-06-01

485

Achieving a vanishing SNR-gap to exact lattice decoding at a subexponential complexity  

CERN Document Server

The work identifies the first lattice decoding solution that achieves, in the general outage-limited MIMO setting and in the high-rate and high-SNR limit, both a vanishing gap to the error-performance of the (DMT optimal) exact solution of preprocessed lattice decoding, as well as a computational complexity that is subexponential in the number of codeword bits. The proposed solution employs lattice reduction (LR)-aided regularized (lattice) sphere decoding and proper timeout policies. These performance and complexity guarantees hold for most MIMO scenarios, all reasonable fading statistics, all channel dimensions and all full-rate lattice codes. In sharp contrast to the above manageable complexity, the complexity of other standard preprocessed lattice decoding solutions is shown here to be extremely high. Specifically the work is first to quantify the complexity of these lattice (sphere) decoding solutions and to prove the surprising result that the complexity ...

2011-01-01

486

Ability of a solid state fermentation technique to significantly minimize catabolic repression of. alpha. -amylase production by Bacillus licheniformis M27  

Energy Technology Data Exchange (ETDEWEB)

The production of {alpha}-amylase by Bacillus licheniformis M27 in submerged fermentation was completely inhibited due to catabolic repression in medium containing 1% glucose. In contrast, the enzyme production in a solid state fermentation system was 19,550 units/ml extract even when the medium contained 15% glucose. The peak in enzyme titre was, however, shifted from 48 to 72 h. The ability of the solid state fermentation system to significantly overcome catabolic repression was not known earlier and is probably conferred by various physico-chemical factors and culture conditions specific to the system. (orig.).

1991-08-01

487

AFM Imaging of SWI/SNF action: mapping the nucleosome remodeling and sliding  

CERN Document Server

We propose a combined experimental (Atomic Force Microscopy) and theoretical study of the structural and dynamical properties of nucleosomes. In contrast to biochemical approaches, this method allows to determine simultaneously the DNA complexed length distribution and nucleosome position in various contexts. First, we show that differences in the nucleo-proteic structure observed between conventional H2A and H2A.Bbd variant nucleosomes induce quantitative changes in the in the length distribution of DNA complexed with histones. Then, the sliding action of remodeling complex SWI/SNF is characterized through the evolution of the nucleosome position and wrapped DNA length mapping. Using a linear energetic model for the distribution of DNA complexed length, we extract the net wrapping energy of DNA onto the histone octamer, and compare it to previous studies.

2007-01-01

488

A study on the power system stabilizer using discrete-time adaptive sliding mode control  

Energy Technology Data Exchange (ETDEWEB)

In this paper the newly developed discrete-time adaptive sliding mode control method is proposed and applied to the power system stabilization problem. In contrast to the conventional continuous-time sliding mode controller, the proposed method is developed in the discrete-time domain and based on the input/output measurements instead of the continuous-time and the full-states feedback, respectively. Because the proposed control method has the adaptivity property in addition to the natural robustness property of the sliding mode control, it is possible to design the power system stabilizer which can overcome both the minor variations of the parameters of the power system and the diverse operating conditions and faults of the power system. Mathematical proof and the various computer simulations are done to verify the performance and stability of the proposed method. (author). 14 refs., 12 figs., 1 tab.

1996-02-01

489

A study on effects of parameters in the Lagrangian code based on F.E.M. through oblique dual-plates perforation phenomena  

International Nuclear Information System (INIS)

This study is concerned to the perforation phenomena of the oblique dual-plate by projectile. Experiment and simulation related to that was carried out. the variables considered in this phenomena include the electrolytic zinc coated steel sheet and carbon steel rod. In the former, the confirmation and projectile velocity possible phenomena of real phenomena is done, the latter, the effect of parameter such as time-step and grid space length is analyzed by using the three-dimensional Lagrangian explicit time-integration finite element code, HEMP. This code use the eight node hexahedral elements and in this study, Von-Mises Criteria is used as the strength model, Mie-Gruneisen is as the Equation of State. The simulation was performed by contrast with the experiment. Through the calibration of the parameter of Lagrangian code, reasonable result was approached.

2004-11-03

490

A classical model for the magnetic field-induced Wigner crystallization in quantum dots  

Energy Technology Data Exchange (ETDEWEB)

A classical model is presented for magnetic field-induced Wigner crystallization in electron systems confined within two-dimensional quantum dots. In contrast to other classical models, this one does not treat an electron as a point charge; the electron density is assumed to take a Gaussian form corresponding to the lowest Landau level. Using a Monte Carlo method we have determined the equilibrium configurations as functions of the magnetic field. We have found a classical counterpart of the quantum maximum density droplet (MDD) and studied the breakdown of the MDD into a Wigner molecule as well as the transformations of the Wigner molecule shape induced by the external magnetic field. The phase diagram for the classical Wigner molecules has been presented and its qualitative agreement with previous quantum mechanical calculations has been shown.

2004-03-03

491

Quantitative analysis of spinal CSF dynamics using magnetic resonance imaging: experimental and clinical studies; MR-tomographische Liquorflussmessungen am Spinalkanal mit einem optimierten MRT-Protokoll: experimentelle und klinische Untersuchungen  

Energy Technology Data Exchange (ETDEWEB)

Purpose: Measurement of the oscillating CSF flow in the spinal canal (SC) of healthy volunteers and in patients with post-traumatic syringomyelia (PTS) using an optimized MRI protocol as well as to determine whether stenosis induced velocity changes are detectable using MRI. Methods: In 68 healthy volunteers quantitative studies of CSF flow in the cervical, thoracic, and lumbar regions were performed. First, an optimized sequence was developed and tested in 19 volunteers using four different flow-encoding velocities (4, 8, 12, 16 cm/s). Secondly, the optimized sequence was employed in 49 volunteers to measure the different CSF patterns in the cervical, thoracic, and lumbar spinal canals (CSC, TSC, LSC). Part three of the study, in which patients with PTS are being examined is still underway. We measured the maximum velocity (cm/s), the pixel area (mm{sup 2}), and the stroke volume (ml/s). Using a flow model the velocities prior to and after compression with 5 different power levels ...

2001-04-01

492

Transarterial Chemoembolization (TACE) for Inoperable Intrahepatic Cholangiocarcinoma  

International Nuclear Information System (INIS)

The aim of this retrospective study was to determine the safety and efficacy of chemoembolization (TACE) as palliative treatment for patients with unresectable intrahepatic cholangiocarcinoma (CCA) and to compare the results with those in the literature. Fifteen patients with histology-proven CCA (5 men, 10 women) had received palliative treatment with TACE over a 6-year period. The treatment protocol comprised repeated TACE at a minimum of 8-week intervals. TACE was performed with a mixture of 10 ml Lipiodol and 10 mg mitomycin C injected into the tumor-supplying vessels. Follow-up investigations after 8-10 weeks comprised contrast-enhanced multislice spiral CT and laboratory control. Statistical evaluation included survival analysis using the Kaplan-Meier method. During the investigation period 58 TACEs (3.9 #+-# 3.8; 1-15) were performed in 15 patients. Mean tumor size was 10.8 #+-# 4.6 cm (range, 2.0-18.0 cm). Unifocal tumor disease was diagnosed in eight ...

2007-11-01

493

Three-dimensional rotational angiography of the carotid arteries with high-flow injection from the aortic arch. Preliminary experience  

International Nuclear Information System (INIS)

Purpose: Three-dimensional rotational angiography (3DRA) is a new technique based on a rotational angiographic acquisition able to display arterial vessels in a 3D rendering mode. The system was mainly developed for neuroradiological evaluations but preliminary extracranial experiences have also been reported. The aim of our work was to compare the results of three-dimensional angiography of the carotid arteries done with high-flow injection of contrast medium from the aortic arch with the results of selective angiography. Materials and methods: Twenty patients underwent digital angiography of the supra-aortic vessels in order to quantify a stenosis of the carotid bifurcations previously detected at Doppler Ultrasound. Examinations were performed with the Philips Integris Allura system provided with the rotational angiography (RA) tool connected to a workstation for three-dimensional reconstruction able to display vessels in a 3D fashion (Volume Rendering, Shaded ...

494

Structure-function studies on inhibitory activity of Bungarus multicinctus protease inhibitor-like protein on matrix metalloprotease-2, and invasion and migration of human neuroblastoma SK-N-SH cells.  

Science.gov (United States)

In view of the findings that several Kunitz-type protein inhibitors suppress tumor invasion and metastasis, the aim of the present study is to explore whether Bungarus multicinctus protease inhibitor-like protein-2 (PILP-2) and PILP-3 exhibit anti-tumor activity. Although approximately 28% of amino acid substitutions occurred between PILP-2 and PILP-3, molecular modeling suggested that PILP-2 and PILP-3 shared similar folded structures. Unlike PILP-2, PILP-3 showed a notable activity in abolishing migration and invasion of human neuroblastoma SK-N-SH cells. The ability of PILP-3 to inhibit matrix metalloprotease-2 (MMP-2) activity was higher than that of PILP-2. Pull-down assay revealed protein-protein interaction between PILP-3 and MMP-2. In contrast to mutation on N-terminal region, replacement of amino acids at C-terminus attenuated notably the ability of PILP-3 to inhibit cell invasion, cell migration and MMP-2 activity as well as the binding capability of ...

2009-08-23

495

Neuromuscular effects of candoxin, a novel toxin from the venom of the Malayan krait (Bungarus candidus).  

Science.gov (United States)

1 Candoxin (MW 7334.6), a novel toxin isolated from the venom of the Malayan krait Bungarus candidus, belongs to the poorly characterized subfamily of nonconventional three-finger toxins present in Elapid venoms. The current study details the pharmacological effects of candoxin at the neuromuscular junction. 2 Candoxin produces a novel pattern of neuromuscular blockade in isolated nerve-muscle preparations and the tibialis anterior muscle of anaesthetized rats. In contrast to the virtually irreversible postsynaptic neuromuscular blockade produced by curaremimetic alpha-neurotoxins, the neuromuscular blockade produced by candoxin was rapidly and completely reversed by washing or by the addition of the anticholinesterase neostigmine. 3 Candoxin also produced significant train-of-four fade during the onset of and recovery from neuromuscular blockade, both, in vitro and in vivo. The fade phenomenon has been attributed to a blockade of putative presynaptic nicotinic ...

2003-06-01

496

Model of blood-brain transfer of oxygen explains nonlinear flow-metabolism coupling during stimulation of visual cortex.  

DEFF Research Database (Denmark)

The coupling between cerebral metabolic rate of oxygen (CMRO2) and blood flow (CBF) in response to visual stimulation was evaluated by means of a model of oxygen delivery. The model predicted a nonlinear relationship between stimulus-evoked changes of oxygen consumption and blood flow. The magnitude of the CMRO2/CBF ratio index (IO2) was used to indicate the degree of flow-metabolism coupling prevailing in specific areas of the brain during physiological stimulation. Therefore, the index provided a measure of the blood oxygenation level dependent (BOLD) magnetic resonance contrast. To evaluate the changes of IO2 in response to visual stimulation, the model was applied to the effect of a changing flicker rate of a visual stimulus on the magnitudes of CBF, CMRO2, and oxygen diffusion capacity, in the human brain. Positron emission tomography (PET) was used to measure the CBF and the CMRO2 in 12 healthy volunteers who viewed a cross-hair (baseline) or a yellow-blue ...

2000-01-01

497

Influence of contrast-enhanced CT and MRI with or without SPIO particles on therapy and therapy costs for patients with focal liver disease  

International Nuclear Information System (INIS)

Purpose: Evaluation of the diagnostic efficacy and cost-benefit of contrast enhanced CT (CT) and MRI pre- and post-SPIO-particles in focal hepatic disease with consideration of therapeutic outcome. Results: In 34/52 (65.4%) of the cases the correct diagnosis was primarily stated by CT (sensitivity [se.] 85.2%, specificity [sp.] 44.0%). In additional 10/52 of the cases unenhanced MRI (se. 91.4%, sp. 75.0%) enabled correct diagnoses, and in another 6 cases the diagnosis was established only by SPIO-MRI (se. 100%, sp. 86.7%). Considering the possible therapeutic recommendation arising from each modality, CT would have induced needless therapy costs of 191,042 DM, unenhanced MRI of 171,035 DM, and SPIO-MRI of 7,311 DM. In comparison to the real therapy costs of 221,873 DM, this would have corresponded to an unnecessary increase of therapy costs of 86.1%, 77.1%, and 3.3%, respectively. In two cases (91 hemangioma, 1 regenerative nodule) all modalities failed, causing ...

2000-03-01

498

Dual energy virtual CT colonoscopy with dual source computed tomography. Initial experience  

International Nuclear Information System (INIS)

Purpose: To describe the technique of DE MDCT colonoscopy and to assess its feasibility. Materials and Methods: 8 patients were scanned with DSCT with a DE scan protocol and dose modulation software. Analysis was performed using dedicated DE software. Prone non-contrast images and DE supine images after contrast injection were obtained. Results: DE colonoscopic images were successfully obtained in 7 patients, but the FOV did not cover all colonic segments in 1 patient, thus resulting in a technical success rate was 87.5%. Streak artifacts were present in the pelvic region in 2 patients. Virtual unenhanced images and iodine map images were obtained for all patients. In 1 patient a polypoid non-enhancing structure was noted on the iodine map, and conventional colonoscopy revealed impacted stool. Enhancing rectal cancer in 1 patient was correctly shown on the iodine map. Iodine maps helped to differentiate stool fragments/retained fluid by the ...

2009-09-01

499

Diagnosis of plasmocytomas using magnetic resonance imaging  

International Nuclear Information System (INIS)

Background. In multiple myeloma 5 different infiltration patterns can be differentiated: 1. Normal appearance of bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. 'salt-and pepper' pattern with inhomogeneous bone marrow with interposition of fat islands. Methods. For the fast and total acquisition of all patterns a combination of a T1-weighted spin echo sequence and a fat suppression technique is superior. The focal involvement is clearly demonstrated as areas of high signal intensity on e.g. STIR images. Diffuse involvement can be quantified objectively by calculation of the percentage of signal intensity increase after contrast material injection. MRI is superior to X-ray in focal and diffuse involvement. With ultrafast sequences a 'screening' of the whole red bone marrow as for myeloma infiltration is possible. Prognosis. In prognosis studies diffuse infiltration is inferior to focal ...

2000-08-01

500

CT colonography with minimal bowel preparation: evaluation of tagging quality, patient acceptance and diagnostic accuracy in two iodine-based preparation schemes  

Energy Technology Data Exchange (ETDEWEB)

The aim of this study was to compare a 1-day with a 2-day iodine bowel preparation for CT colonography in a positive faecal occult blood test (FOBT) screening population. One hundred consecutive patients underwent CT colonography and colonoscopy with segmental unblinding. The first 50 patients (group 1) ingested 7*50 ml iodinated contrast starting 2 days before CT colonography. The latter 50 patients (group 2) ingested 4*50 ml iodinated contrast starting 1 day before CT colonography. Per colonic segment measurements of residual stool attenuation and homogeneity were performed, and a subjective evaluation of tagging quality (grade 1-5) was done. Independently, two reviewers performed polyp and carcinoma detection. The tagging density was 638 and 618 HU (p = 0.458) and homogeneity 91 and 86 HU for groups 1 and 2, respectively (p = 0.145). The tagging quality was graded 5 (excellent) in 90% of all segments in group 1 and 91% in group 2 (p = ...

2010-02-15