Digital mammography: more microcalcifications, more columnar cell lesions without atypia
British Library Electronic Table of Contents (United Kingdom)
The incidence of columnar cell lesions in breast core needle biopsies since full-field digital mammography in comparison with screen-filmed mammography was analyzed. As tiny microcalcifications characterize columnar cell lesions at mammography, we hypothesized that more columnar cell lesions are diagnosed since full-field digital mammography due to its higher sensitivity for microcalcifications. In all, 3437 breast core needle biopsies performed in three hospitals and resulting from in total 55?159 mammographies were revised: 1424 taken in the screen-filmed mammography and 2013 in the full-field digital mammography period. Between the screen-filmed mammography and full-field digital mammography periods, we compared the proportion of mammographies that led to core needle biopsies, the...
2011-01-01
International Nuclear Information System (INIS)
Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this method, we conducted evaluation of the images of ...
2002-03-01
Evaluation of FCR system by means of NEQ(u)
Energy Technology Data Exchange (ETDEWEB)
A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We concluded that it is necessary to compare with the screen-film ...
1991-07-01
Evaluation of FCR system by means of NEQ(u)
International Nuclear Information System (INIS)
A number of noise equivalent quanta (NEQ(u)) has been used in the evaluation of imaging systems. In this paper, we have evaluated the image quality of Fuji computed radiography (FCR) using of NEQ (u) and considered with the effects of the aliasing error of the FCR. The noise samples of the FCR were made by three different exposure levels, and one of these has the same exposure level of the screen-film system. These samples were set with the same characteristic curve condition as that of the screen-film system. Results indicate that NEQ (u) of the FCR system at low frequencies varies depending on the exposure level. On the same exposure level, NEQ(u) of screen-film system has a higher value than that of FCR in the frequency region over 2.5 cycles/mm. Moreover, the aliasing error of FCR increases at the frequency region over 5 cycles/mm. We concluded that it is necessary to compare with the screen-film ...
1991-01-01
Information detective quantum efficiency of X-ray film-intensifier foil systems
Energy Technology Data Exchange (ETDEWEB)
The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed.
1988-04-01
Information detective quantum efficiency of X-ray film-intensifier foil systems
International Nuclear Information System (INIS)
The capability of screen-film combinations of detection and representation of information is described by the detective quantum efficiency (DQE). The DQE may be calculated from the sensitivity, the gradient of the characteristic curve, the modulation transfer function and the Wiener spectrum. These parameters have been determined for fourteen screen-film combinations and the DQE's have been calculated. It is shown that the low frequency region the DQE does not depend on spatial frequency. This constant level of DQE is mostly dependent on the absorbance of the screens. Consequences from this fact, as well for the manufacturer as for the user of the screens, are discussed. (orig.).
Gadolinium electronic band structure: augmented plane wave calculation
International Nuclear Information System (INIS)
Augmented plane wave calculation of gadolinium electronic structure crystallized in a hexagonal close-packed lattice is carried out.
Energy Technology Data Exchange (ETDEWEB)
The structural change of the (100-x)(0.6Li{sub 2}S{center_dot}0.4SiS{sub 2})centre dotxLi{sub 3}PO{sub 4} oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO{sub n}S{sub 4-n} (n=1,2,3) and PO{sub n}S{sub 4-n} (n=1,2,3) present in the glass samples vanished and the SiS{sub 4}, PS{sub 4}, SiO{sub 4} units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S{sup 2-} increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)
1999-02-01
Energy Technology Data Exchange (ETDEWEB)
The structural change of the (100-x)(0.6Li[sub 2]S[center dot]0.4SiS[sub 2])centre dotxLi[sub 3]PO[sub 4] oxysulfide glassesduring crystallization was analyzed by means of solid-state nuclear magnetic resonance (NMR) and X-ray photoelectron spectroscopy (XPS). The unique tetrahedral units of SiO[sub n]S[sub 4-n] (n=1,2,3) and PO[sub n]S[sub 4-n] (n=1,2,3) present in the glass samples vanished and the SiS[sub 4], PS[sub 4], SiO[sub 4] units increased with proceeding of the crystallization process. Nonbridging sulfur and oxygen atoms decreased while bridging oxygens and S[sup 2-] increased with proceeding of the crystallization process. Large structural difference between the glass and the corresponding crystallized sample explained the high stability against crystallization found in the oxysulfide glass with the composition of X=5. (author)
1999-02-01
Energy Technology Data Exchange (ETDEWEB)
Thermal, electrical, and electrochemical properties were investigated for the (100-x)(0.6Li{sub 2}S{center{underscore}dot}0.4SiS{sub 2}){center{underscore}dot}xLi{sub 4}SiO{sub 4} oxysulfide glasses. The glass with x = 5 exhibited high electrical conductivity of about 10{sup {minus}3} S cm{sup {minus}1} at room temperature, high glass stability against crystallization, and good chemical stability in contact with Li metal. Cyclic voltammetry also suggested that this glass has a wide electrochemical window of more than 10 V. On the other hand, further addition of Li{sub 4}SiO{sub 4} up to 20 mol% lowered the conductivity, glass stability against crystallization, and electrochemical stability for the oxysulfide glasses.
1999-09-01
Screen-film-combinations for radiography - present and future spectrum of application
Energy Technology Data Exchange (ETDEWEB)
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.
1985-01-01
Screen-film-combinations for radiography - present and future spectrum of application
International Nuclear Information System (INIS)
From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).
Clinical application of FCR for the portable chest radiographs in ICU
Energy Technology Data Exchange (ETDEWEB)
The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).
1989-08-01
Clinical application of FCR for the portable chest radiographs in ICU
International Nuclear Information System (INIS)
The diagnostic value of the portable chest radiography obtained with Fuji computed radiography (FCR) was evaluated in comparison with conventional images in 23 patients who were admitted to ICU in Yokohama City University Hospital. On the whole , FCR produced more exellent images than conventional screen-film radiographs. Especially the evaluation for the demonstration of the catheters, the endotracheal tubes and the tracheal shadows obtained high score. We discuss the clinically utility of FCR for the portable chest radiographs in ICU. (author).
1989-01-01
UK PubMed Central (United Kingdom)
Background and objectives: The pathogenesis of acquired nephrogenic systemic fibrosis recently described for patients with renal insufficiency and a history of exposition to gadolinium-based magnetic...Full Text Available
2008-07-01
Moment of inertia calculations for some even-even rare earth nuclei
International Nuclear Information System (INIS)
... angular momentum cranking model even-even nuclei gadolinium 156 governor
Augmented-plane-wave calculation of indirect-exchange matrix elements for gadolinium
International Nuclear Information System (INIS)
(15 Dec 1974). United States Harmon, BN Freeman, AJ Ames
Experience in using Fuji computed radiography (FCR), 1
Energy Technology Data Exchange (ETDEWEB)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation doses of the chest were reduced at the rate ...
1984-12-01
Experience in using Fuji computed radiography (FCR), 1
International Nuclear Information System (INIS)
New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR system the radiation doses of the chest were reduced at the rate ...
1984-01-01
International Nuclear Information System (INIS)
To assess the diagnostic capability Fuji computed radiography (FCR) using a dual side reading system was compared to the conventional radiography using a film-screen system. Twenty-eight patients with lung cancer were examined with a new FCR system (FCR 5501D) and a conventional screen-film system concurrently. FCR utilizes a reading system that detects emissions from dual sides of imaging plate. Chest X-rays were obtained with same exposure factors in both systems. Image qualities of both systems were compared by two radiologists using a five-level score. There were no lesion that FCR images were inferior to film-screen images. The frequency of score +1 or +2 that FCR images were superior to film-screen images was 31% in large nodular shadows, 40% in accompanying shadows with a nodule, 67% of small nodular shadows, and 43% of the lymph node swelling in the hilum of the lung or mediastinum. In large nodular shadows which were the most frequent abnormality score +1 ...
2003-02-01
Energy Technology Data Exchange (ETDEWEB)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-05-01
International Nuclear Information System (INIS)
The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).
1991-01-01
Detection of intracardiac calcification using Fuji computed radiography
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) was evaluated for detection of intracardiac calcification as compared with conventional radiography in 77 patients. Intracardiac calcification was found in 37 patients (left coronary artery: 31, right coronary artery: 11, valve: 9) on cine-fluorography. The sensitivity for detecting these calcified foci with FCR was higher than conventional screen-film method. Especially, sensitivity for detecting left coronary artery calcification with FCR was significantly higher than conventional method (71 %, 32 %) (p < 0.01), Fine anatomical details of calcification were well shown on FCR. Chest radiography using FCR is of great use for detection of intracardiac calcification. (author).
1986-01-01
International Nuclear Information System (INIS)
In 16 female patients wick colpourethrocystography was performed directly successively with large-size films as well as medium-size films (intensifier fluorography). The area exposure products were measured by a dosemeter closely attached to the diaphragm and separately for radiography and fluorography, resp. Surface doses as well as organ doses were calculated according to Rosenstein. The average radiatin doses of the active bone marrow were 6.03 mGy for examination with large-size films and 1.27 mGy for fluorography; the average gonadal doses were 7.45 mGy and 1.56 mGy, resp. The portion of fluoroscopy in radiation exposure amounted to 14.8% in large-size film examination, but was 74.0% in medium-size examination. Thus the comparative results revealed a significant reduction of the patient's radiation dose by application of intensifier fluorography in colpourethrocystography.
1987-01-01
Application of digital radiography to diagnosis of laryngeal diseases
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) is a new system of digital radiography that is based on the latest computer technologies. We applied this FCR system to the X-ray diagnosis of the laryngeal disease. Twenty patients with various laryngeal diseases were evaluated by both FCR frontal tomography and conventional screen-film frontal tomography under the same exposure condition. Both tomograms were then compared on the subject of the clarity of delineation of laryngeal structures. As the result, FCR tomograms revealed the feature of the laryngeal lumen and cartilages more clearly than conventional tomograms. In addition, energy subtraction method, which is one of FCR image processing systems, was presented as a new technical procedure to extinguish cervical spine shadows in plain anteroposterior laryngeal X-photograph. We stress that FCR system is the suitable procedure for X-ray analysis of laryngeal diseases, especially in the region related with the phono-surgery. ...
1986-01-01
Use of gadolinium as neutron poison in 540 MWe PHWR
International Nuclear Information System (INIS)
In Pressurised heavy water reactors (PHWRs), neutron poison in the moderator is used to compensate the excess reactivity present in the core on different occasions such as xenon decay during synchronization just after poison out period or start ups from xenon free conditions. It is also used in secondary shutdown system (SDS-2), where required amount of neutron poison is injected directly into the moderator within 2.5 seconds. Further, it is also used for over poisoning the moderator to achieve the guaranteed shutdown state when the regular shutdown systems are taken for maintenance. Generally, two types of moderator poisons are used in power reactors to balance the reactivity of the core and they are boron and gadolinium. Gadolinium is used in the form of gadolinium nitrate (Gd(NO3)3.6H2O). The paper gives the details of estimation of reactivity coefficients of gadolinium for 540 MWe PHWR for different ...
2006-11-13
Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array
The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a ...
2009-03-10
Regional Convection-Enhanced Delivery of Gadolinium-labeled Albumin in the Rat Hippocampus In Vivo
UK PubMed Central (United Kingdom)
Convection-enhanced delivery (CED) has emerged as a promising method of targeted drug-delivery for treating central nervous system (CNS) disorders, but the influence of brain structure on infusate...Full Text Available
2010-03-15
UK PubMed Central (United Kingdom)
Arriving at a firm diagnosis of neurosarcoidosis continues to pose serious problems, particularly when evidence of granulomatous disease outside the nervous system is lacking. The commonest mode of...Full Text Available
1991-06-01
UK PubMed Central (United Kingdom)
A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.
2010-06-07
Gadolinium-containing phosphatidylserine liposomes for molecular imaging of atherosclerosis
UK PubMed Central (United Kingdom)
Exteriorized phosphatidylserine (PS) residues in apoptotic cells trigger rapid phagocytosis by macrophage scavenger receptor pathways. Mimicking apoptosis with liposomes containing PS may represent...Full Text Available
2009-11-01
Convection-enhanced Delivery of Free Gadolinium with the Recombinant Immunotoxin MR1-1
UK PubMed Central (United Kingdom)
PurposeA major obstacle in glioblastoma (GBM) therapy is the restrictive nature of the blood-brain barrier (BBB). Convection-enhanced delivery (CED) is a novel method...Full Text Available
2010-05-01
International Nuclear Information System (INIS)
The use of Gadolinium-DTPA as a paramagnetic contrast agent in MRI with adults and juveniles concerning brain and spinal cord pathology is well proven since years. In the FRG it is only introduced for children over two years of age. Therefore this report deales with the experience in four infants and small children under the age of two. They all were suffering from neurological tumors and got additional diagnostic information in three cases. Clinical side-effects like urticaria, vomiting or convulsions had not been observed nor had pathologic changes of the biochemical parameters been noticed. (orig./GDG).
Energy Technology Data Exchange (ETDEWEB)
Recently the association of a rare disease named ''nephrogenic systemic fibrosis'' (NSF) with the administration of gadolinium-containing contrast media, especially gadodiamide (Omniscan, GE-Healthcare), was described. NSF is a scleroderma-like disease characterised by widespread tissue fibrosis. Until now, NSF cases were observed only in patients with kidney disease. Almost all patients were suffering from chronic renal insufficiency, 90 % of them required renal replacement therapy. The true incidence of the disease is unknown. First retrospective analyses of selected collectives of patients with end-stage renal disease showed 2 - 5 % cases of NSF after administration of Gadolinium-containing contrast agents with an odds ratio of 20 - 50 in comparison to non-exposed controls. NSF is a serious adverse reaction, which may result in severe disabilities and even death. Therefore all radiologists applying ...
2007-06-15
Energy Technology Data Exchange (ETDEWEB)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same accuracy as the ...
1993-06-01
The application of the Fuji Computed Radiography system for the diagnosis of pneumoconiosis
International Nuclear Information System (INIS)
A computer controlled digital system, Fuji Computed Radiography (FCR) is capable of providing more stable output image than conventional screen/film system. So FCR would be an ideal system for the detection of pneumoconiosis due to the constant high quality of the output films. We tried to find the optimum image processing to compensate the small size (1/2 in length of a full-size radiograph) of the output image of digital radiography. The best result for FCR was given with gamma 0.85 and 0.30 enhancement of response at spatial frequency of 0.085 cycle/mm. On the other hand, the digitally processed FCR size ILO standard films, the characteristics of which is different from FCR output films, proved to be most preferable when the image processing is made with gamma 0.85 and 0.25 enhancement at spacial frequency of 0.17 cycle/mm. If the above mentioned image processings are adopted, FCR can be used for the diagnosis of pneumoconiosis with the same accuracy as the ...
1993-01-01
MTF analysis of the MURR real-time neutron radiography facility
International Nuclear Information System (INIS)
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a knife-edge, differentiate the edge gradient to obtain the line spread ...
1982-04-01
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
International Nuclear Information System (INIS)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is usually difficult to obtain clear cervicothoracic films in conventional radiography. We can obtain much precise information about the spinal ...
1987-01-01
Energy Technology Data Exchange (ETDEWEB)
The principle of radiodiagnosis consists in the fact the X-ray beam is attenuated at different degrees by distinct tissues. For this reason, the anatomical structures have distinct radiological opacities, that produce the radiographic image. The progresses in radiology are related to the development if new radiographic image formation systems that enable an amplification in the quality, with low dose and/or risk to the patient. The objective of this work is the sensitometric valuation of a screen-film combination, that is still the most used, for the standardization, of radiographic images. Thinking about this, were constructed homogeneous phantoms of the chest, skull and pelvis, for the calibration of X-ray beams, with the purpose of obtaining radiographic images of good quality, basing in the routine of a radiodiagnosis service and in the scientific knowledge. Questions were approached about the choice of the suitable equipment, that allow the obtention of k Vp ...
1996-12-31
Synthesis and photoluminescence properties of Sm3+-doped LaMgB5O10 and GdMgB5O10
International Nuclear Information System (INIS)
Luminescence and reflection spectra as well as luminescence kinetics of the 1 mol% Sm3+-doped crystalline lanthanum magnesium meta borate (LaMgB5O10) and gadolinium magnesium meta borate (GdMgB5O10) were analyzed. Materials were synthesized by conventional solid state route and showed bright orange-red emission under UV excitation. Emission spectra contain sharp and well resolved Sm3+4G5/2#->#6HJ transitions indicating a strong crystal-field effect. In case of gadolinium compound energy transfer between Gd3+ and Sm3+ was detected. The luminescent kinetics of the Sm3+ in analyzed powders is characterized by single exponential decay and experimental values vary in the range 2.2-2.4 ms. - Research highlights: ? Phosphorescence of samarium-doped lanthanide magnesium meta borates. ? Bright and well resolved orange-red emission of Sm3+ under UV excitation. ? Energy transfer from Gd3+ to Sm3+ in gadolinium magnesium meta borate ...
2011-07-01
Spectroscopy of gadolinium gallium garnet crystals doped with Y b3+ revisited
International Nuclear Information System (INIS)
The optical spectroscopy measurements of gadolinium gallium garnet (GGG) crystals doped with Yb show evidence of the presence of non-equivalent optical centers with very similar radiative decay rates. The energy level schemes of those centers have been determined on the basis of optical absorption, luminescence and Raman experiments. Crystal field fitting resulted in two sets of slightly different crystal field parameters for two non-equivalent Yb centers. Both sets of parameters describe perfectly the experimentally detected Y b3+ energy levels. Correlation between systematic trends in the experimental energy level schemes and crystal field parameters is discussed.
2010-06-30
International Nuclear Information System (INIS)
New Schiff base chelating ligands were synthesized by reacting equimolar quantities of 2,3-dimethyl-4-formyl-1-phenyl-3-pyrazoline-5-one and o-anisidine, p-anisidine, m-anisidine, o-toluidine, p-toluidine, m-toluidine, 2,6-xylidine or 2,4-xylidine in ethanol medium. Their subsequent reaction with gadolinium (III) nitrate hexahydrate in 2:1 molar ratio gave complexes that were characterized by elemental analyses, molar conductances, magnetic measurements, electronic and I.R. spectral studies. All the chelates were found to be non-electrolytic in nature. (author). 15 refs., 1 fig., 1 tab.
1994-01-01
Characteristic features of intracranial meningiomas on magnetic resonance tomography
International Nuclear Information System (INIS)
Twenty-three patients with intracranial meningiomas were examined by means of magnetic resonance tomography (MRT). In 13 patients the paramagnetic contrast medium gadolinium DTPA was used. Meningiomas show only slight changes in signal intensity compared with brain in the spin-echo mode, the greatest contrast being found on photon density images (TR 1600 ms, TE 35 ms). In T1 images more than 50% of the patients showed a low signal margin between tumour and brain. Hyperostosis of the calvarium is easily recognised, but MRT is unreliable for showing tumour calcification. After intravenous injection of gadolinium DTPA, there was marked homogeneous uptake in the meningiomas. These signs are useful for the diagnosis of a meningioma by MRT. (orig.).
UK PubMed Central (United Kingdom)
Gadolinium (Gd) based contrast agents (GBCAs) in magnetic resonance imaging (MRI) are used in daily clinical practice and appear safe in most patients; however, nephrogenic systemic fibrosis...Full Text Available
2009-03-01
International Nuclear Information System (INIS)
Gadolinium nitrate has been employed in Indian nuclear reactors for the first time as soluble neutron poison in the heavy water moderators of the 540 MWe PHWRs TAPS 3 and 4, as a fast acting secondary shut down system (SDS-2); and also for reactivity shim. For this purpose, the moderator purification system is currently equipped with special ion-exchange columns/schemes, developed by present authors. However, for gadolinium removal from moderator in the post SDS-2 scenario, the two stage ion-exchange - cation bed operation followed by mixed bed operation - results in low pH conditions persisting in the moderator for a few hours, which gives rise to certain operational problems. The present paper describes a mixed bed ion-exchange scheme employing macro-porous strong acid cation and macro-porous weak base anion resins, which has been developed to eliminate acidic conditions and gives a better pH control. The cation to anion capacity ratio in the ...
2008-12-01
Current diagnosis of tumors developed in the internal auditory canal and cerebellopontine angle
Energy Technology Data Exchange (ETDEWEB)
The introduction of CT scan and, more recently, magnetic resonance imaging, has radically changed the diagnostic approach to tumors developed in the internal auditory canal and cerebellopontine angle. CT scan with intravenous injection visualizes tumors lying in the cerebellopontine angle. Magnetic resonance imaging, especially using gadolinium, is a very accurate means for diagnosing tumors of both the auditory canal and cerebellopontine angle.
1988-10-13
The clinical significance of Fuji computed radiography on lateral chest radiogram
Energy Technology Data Exchange (ETDEWEB)
The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, ...
1995-02-01
The clinical significance of Fuji computed radiography on lateral chest radiogram
International Nuclear Information System (INIS)
The purpose of this study was to clarify the benefits of digital lateral chest radiogram. In the basic study, the modulation transfer factor (MTF) and the wiener spectra (WS) of conventional screen film (CSF) and Fuji computed radiography (FCR) were measured. The visibility of the simulated nodules on FCR using 3 human bodies was subjectively compared with that on CSF by 13 observers. In the clinical study, the visibility of the normal structures on FCR was subjectively compared with that on CSF using 50 lateral chest radiograms by 10 observers. The diagnostic performance to detect pulmonary nodules on FCR was also compared with that on CSF using each 30 positive and negative cases by 8 observers. In the basic study, the MTF of FCR was superior to that of CSF, and the WS of FCR displayed in half size was superior to that of CSF. In all exposure conditions, the visibility of the nodules on FCR in the pulmonary apex was inferior to that on CSF, ...
1995-01-01
Fuji computed radiography (FCR) for the diagnosis of spinal disorders
Energy Technology Data Exchange (ETDEWEB)
Since April, 1985, we have, in co-operation with the Fuji Film Co., Ltd., used Fuji Computed Radiography (FCR) in the diagnosis of spinal disorders. FCR is a new computed radiographic system which uses an energy-storage phosphorus panel called an ''Imaging Plate'' as an image sensor. The ''Imaging Plate'' can be used to obtain radiographs in exactly the same way as the screen-film combination used in conventional radiography; X-rays are exposed on the ''Imaging Plate'' instead of X-ray film in the conventional fashion, and then the ''Imaging Plate'' is calculated. The processed digital data from the scans is transformed into a picture by means of digital-to-analogue conversion. The pictures are always clear and beautiful. Plain films of the spine taken by FCR are even clearer, even in the cervicothoracic region, where it is ...
1987-04-01
International Nuclear Information System (INIS)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm"-"1, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system were better than those of FCR system a little ...
2002-12-01
Energy Technology Data Exchange (ETDEWEB)
We measured and evaluated digital, pre-sampling and overall imaging properties (characteristic curve, modulation transfer function (MTF), Wiener spectrum (WS), noise equivalent quanta (NEQ)) for Cannon's flat-panel detector (FPD), Fuji computed radiography (FCR) and screen-film (S/F) systems, respectively. First, the digital and overall characteristic curves of FPD and FCR systems were more wide dynamic range than that of the S/F system. Second, the pre-sampling and overall MTF of FPD system were better than those of FCR system a little at lower spatial frequencies than 0.8 mm{sup -1}, but the overall MTF of FPD and FCR systems were worse than that of S/F system a little at all spatial frequencies. Third, the digital and overall WS of FPD system were similar or better than those of FCR system, but the overall WS of FPD and FCR systems were worse than that of S/F system. Fourth, the pre-sampling and overall NEQ of FPD system were better than those of FCR ...
2002-12-01
Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube
Energy Technology Data Exchange (ETDEWEB)
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase contrast improving image quality, a re-scaling effect increases image sharpness in magnification. ...
2008-12-15
Trace metal characterization of the U-Al matrix by atomic spectroscopy
International Nuclear Information System (INIS)
Uranium-aluminum alloys with a significant enrichment of uranium with "2"3"3U or "2"3"5U serve as nuclear fuels in research reactors. The quality assurance of this fuel requires, among other things, precise knowledge that all trace metal constituents that affect neutron economy, fuel integrity, and fuel fabrication process parameters are well within the specification limits. Trace metal characterization of "2"3"5U-Al alloy has been carried out by atomic spectrometry. The trace metal constituents of interest are grouped into common metals (silver, boron, calcium, cadmium, cobalt, chromium, copper, iron, magnesium, manganese, molybdenum, sodium, nickel, lead, silicon, tin, titanium, vanadium, tungsten, and zinc) and lanthanides (cerium, dysprosium, europium, gadolinium, holminium, lutetium, samarium, and terbium). The elements yttrium and zirconium are grouped with the latter in view of the chemical separation procedure used. The alloy samples are dissolved in 6 M ...
Theoretical simulation of SDS - 2 actuation in 540 MWe PHWR
International Nuclear Information System (INIS)
The 540 MWe PHWR has two fully independent shutdown systems. The first shutdown system (SDS-1) comprises of 28 spring assisted, vertical gravity drop shut-off rods, each consisting of a cadmium absorber sandwiched between stainless steel tubes. The second shutdown system (SDS-2) constitutes six poison tanks connected to respective zircaloy injection tubes. This system is capable of high speed injection of gadolinium nitrate solution (in D2O) into the moderator through these tubes. Theoretical estimation was carried out at different injection pressures and different concentration of gadolinium nitrate solution to arrive at the limiting value of these parameters from reactivity consideration point of view. The plant measurements of SDS-2 actuations at 60 and 80 Kg/cm2 pressure of helium was used to validate and upgrade the estimation model. The paper gives the details of the validation details of SDS-2 actuation. (author)
2006-11-13
International Nuclear Information System (INIS)
In a prospective study, 58 patients with carcinomas of the bladder were examined by CT and MRI; in 48, gadolinium-DTPA was administered intravenously. MRI provided exact staging in 89%, compared with 80% with CT. There was 13% over-staging with CT and 11% with MRI. MRI, unlike CT did not result in any under-staging. In 36 patients a quotient could be calculated from the signal intensity of the tumour and surrounding soft tissues both before and after the intravenous contrast medium and the increased quotient after contrast administration could be estimated. There was a significant increase in the tumour/muscle quotient with a mean of 72#+-#22% (minimum 43%, maximum 153%), corresponding to a marked increase of the signal form the tumour when compared with the precontrast images. This had the following advantages compared with CT: Accurate differentiation between superficial and intramural spread. MRI was better than CT at demonstrating tumours in the roof of the ...
Uranium isotopic assay instrument
International Nuclear Information System (INIS)
Full text: The isotopic assay instrument under development at Pacific Northwest National Laboratory (PNNL) is capable of rapid prescreening to detect small and rare particles containing high concentrations of uranium in a heterogeneous sample. The isotopic measurement concept is based on laser vaporization of solid samples followed by sensitive isotope-specific detection using either uranium atomic fluorescence emission or uranium atomic absorbance. Both isotopes are measured concurrently, following a single ablation laser pulse using two external-cavity violet diode lasers. The simultaneous measurement of both isotopes enables the correlation of the fluorescence and absorbance signals on a shot-to-shot basis. This measurement approach demonstrated negligible channel crosstalk between isotopes. Scanning the heterogeneous samples provides high-resolution imagery of sample isotopic fluorescence and absorbance. Isotopically selective excitation of uranium vapor also was the basis of the ...
2006-10-16
Synovial cysts of the lumbar spine: CT and MRI correlations
Energy Technology Data Exchange (ETDEWEB)
Intraspinal synovial cysts were diagnosed in six patients during a 5-year period and retrospectively studied. Plain films of the lumbar spine showed degenerative changes in all patients. Lumbar myelography showed a posterior and lateral defect caused by extradural compression. Using CT without contrast enhancement established the diagnosis in five of the six patients. In four cases MRI was performed, three before and after injection of gadolinium diethyline-triamine penta-acetic acid (Gd-DTPA). Including the patient with a false-negative CT, MRI was positive in all patients. (orig.)
1994-08-01
RBS Characterization of Yttrium Iron Garnet Thin Films
International Nuclear Information System (INIS)
Magnetic materials such as yttrium iron garnet (YIG) are of great importance for its magneto-optic properties and for their potential applications in the domain of optical telecommunications. The deposition of thin films of YIG, on quartz or GGG (gadolinium gallium garnet) substrate, was performed using radio frequency non reactive magnetron sputtering, followed by high temperature annealing which is needed to enhance the crystallinity of the layers. Rutherford backscattering spectrometry RBS was used to determine the thickness and stoichiometry of the performed layers in order to investigate correlations between growth conditions and the quality of the final material. RBS measurements showed the influence of the deposition time and the temperature substrate on the film growth and its stoichiometry. (author)
2008-12-13
International Nuclear Information System (INIS)
The description is presented of binary phase diagrams of titanium alloyed with the following elements: silver, aluminium, arsenic, gold, boron, barium, beryllium, bismuth, carbon, calcium, cadmium, cobalt, chromium, copper, iron, gallium, germanium, hydrogen, hafnium, indium, iridium, potassium, lithium, magnesium, manganese, molybdenum, nitrogen, sodium, niobium, nickel, oxygen, osmium, phosphorus, lead, palladium, platinum, plutonium, rhenium, lanthanium, cerium, preseodymium, neodymium, gadolinium, erbium, terbium, thulium, lutetium, rhodium, ruthenium, scandium, silicon, tin, strontium, tantalum, technetium, thorium, uranium, vanadium, tungsten, yttrium, ytterbium, zinc and zirconium.
British Library Electronic Table of Contents (United Kingdom)
Objective To investigate value of magnetic resonance cholangiopancreatography (MRCP) using oral diluted gadolinium (Gd)-diethylenetriamine penta-acetic acid (DTPA) as negative contrast materials in diagnosis of juxtapapillary duodenal diverticulum with atypical imaging features. Methods Nineteen patients with juxtapapillary duodenal diverticula of which imaging findings were atypical underwent MRCP using oral diluted Gd-DTPA as negative contrast materials after conventional MRCP without any oral contrast materials. Results Twenty diverticula were revealed in the 19 patients. At conventional MRCP, the diverticula appeared as rounded lesion with high signal intensity. After oral administration of diluted Gd-DTPA, they disappeared at MRCP. These entities were diagnosed as duodenal diverticula...
2009-01-01
The use of magnetic resonance imaging for diagnosis and staging of renal cell carcinoma
International Nuclear Information System (INIS)
The use of magnetic resonance imaging for diagnosis and the preoperative staging of renal cell carconoma was evaluated in 79 patients with 88 tumors. Gradient-echo and spin-echo images before and after intravenous administration of Gadolinium DTPA were compared with the results of computed tomography (CT) and histologic staging. The two imaging techniques had comparable results: T-stage was predicted correctly with CT in 78%.4% and with MRI in 84.0% of the cases, while the N-stage was accurately assessed in 81.8% and 79.5%, respectively. MRI had some advantages in diagnosing perirental tumor spread and in excluding an infiltration beyond Gerota's fascia. Therefore, MRI is a true alternative to CT for staging large renal cell carcinomas and especially for patients with contraindications for iodinated contrast agents. (orig.).
Relativistic distorted-wave results for nickel-like gadolinium
Electron collisional data are required for population kinetics modeling and spectral predictions of highly ionized ions in high-temperature plasmas. Nickel-like ions are especially interesting for their potential use in soft X-ray laser schemes pumped by electron collisional excitation and recombination. For highly stripped ions of moderate to high Z, relativistic effects begin to play a role in the atomic-physics calculations. A relativistic multiconfigurational distored-wave model has been used for the calculation of electron excitation cross sections and rate coefficients between the 3s2 3p6 3d10 Ni-like Gd ground state and the singly excited states with an N-shell electron.
1986-08-01
Real time neutron radioscopy - trends and applications
International Nuclear Information System (INIS)
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
2003-11-12
Real time neutron radiography using a Lixi neutron imaging device
Energy Technology Data Exchange (ETDEWEB)
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.
1986-01-15
Real time neutron radiography using a Lixi neutron imaging device
International Nuclear Information System (INIS)
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).
1986-01-01
Energy Technology Data Exchange (ETDEWEB)
Three different fuels UO{sub 2}-only, UO{sub 2}-Gd{sub 2}O{sub 3}(5%), and UO{sub 2}-Gd{sub 2}O{sub 3}(10%) were produced by sol-gel technique. Their powder characteristics such as flowability, BET surface area, average pore diameter, and cumulative pore volume were determined. The pore size distributions of powders, green pellets, and sintered fuels were determined by using a mercury porosimeter. The theoretical densities of sintered fuels were found to be 98.01, 95.3, and 95.9 %, respectively. Their ruggedness fractal dimensions were 1.111, 1.044, and 1.042, while the fractal dimensions associated with the size distribution of grains were 1.44, 1.58, and 1.60, respectively. (orig.).
1996-07-01
International Nuclear Information System (INIS)
A series of cyclic voltammetry, chronoamperometry and electrochemical impedance experiments have been carried out in order to investigate the effect of cathode composition and porosity on the electrochemical characteristics of strontium-doped lanthanum, praseodymium and gadolinium cobaltite cathodes. The impedance responses at different electrode potentials of the half cell and symmetric single cell setups are compared and analyzed by the equivalent circuit modeling method. The deconvolution of impedance spectra for single cell cathode and anode reactions contributions based on the results of simultaneous analysis of half cells and symmetric single cells has been made by differential impedance real part vs. ac frequency plot analysis method. Noticeable influence of cathode chemical composition, meso-porosity and macro-porosity on the electrochemical activity of the oxygen electroreduction has been demonstrated. Seeming activation energy values have been calculated ...
2010-11-01
Design on SDS2 on-line poison concentration monitoring in CANDU
Energy Technology Data Exchange (ETDEWEB)
At the reference plant (Wolsung unit No. 1) a manual poison sampling system is provided to periodically sample gadolinium from each tank and analyze it in the laboratory to provide assurance that adequate poison concentration in each tank is maintained. The AECB required a continuous, on-line monitoring system. On Wolsung unit No. 2, process piping adapter and new instrument loops added to the Liquid Injection Shutdown System(LISS) which is part of SDS2. The new instrument loops continuously monitor SDS2 poison conductivity and initiate an alarm when the poison concentration is too low. 8 refs., 1 fig. (author).
1996-10-01
Energy Technology Data Exchange (ETDEWEB)
To assess the utility of magnetic resonance (MR) imaging in the study of pediatric patients with clinical suspicion of pituitary disease. We studied 18 patients aged 7 to 18 years.Fifteen had hormonal disturbances, two presented amenorrhea and 1 complained of headache, fever and symptoms of polyuria and polydipsia. All the patients were examined using a Siemens SP 42 1-Tesla MRI scanner. Sagittal and coronal T1-weighted spin-echo images were obtained; in addition T2-weighted spin-echo or fast spin-echo imaging was performed in ten cases and intravenous gadolinium was administered in nine. We found 9 patients with hypothalamic-pituitary dysgenesis, 2 with germinoma, 2 cases of pituitary hemosiderosis in patients with thalassemia, 2 cases of microadenoma, one abscess, one case of idiopathic central diabetes insipidus and one of Langerhans cell histiocytosis. MR enabled us to assess pituitary structural alterations in children with hypothalamic-pituitary hormone ...
2000-07-01
International Nuclear Information System (INIS)
The optical absorption of the Tm"3"+ ion in the gadolinium oxychloride (GdOCl) matrix in the UV, visible, and NIR range was studied at temperatures between 9 and 300 K. The visible luminescence of GdOCl:Tm"3"+ under Ar"+ ion laser and mercury lamp excitation was recorded at 9, 77, and 300 K, too. The crystal field (CF) splitting of the "3H_4_-_6, "3F_2_-_4, "1G_4, "1D_2, and "1I_6 levels of the Tm"3"+ ion deduced from the spectra was analysed according to the C_4_v point symmetry of the RE"3"+ site. The resulting energy level scheme, consisting of 39 levels (i.e. 55 Stark components) out of the total of 70 (91) for the whole 4f"1"2 configuration, was simulated with the aid of a phenomenological theory taking simultaneously into account both the free-ion and CF effects. The model included 13 adjustable parameters describing the electrostatic (the Racah parameters E_0_-_3) and the configuration interaction (the Trees parameters #alpha#, #beta#, and #gamma#) as well ...
1995-06-26
International Nuclear Information System (INIS)
Gadolinium removal during the first approach to criticality of TAPP-4 540 MWe reactor using mixed bed resin (strong acid cation resin and weak base anion resin) topped with strong acid cation exchange resin yielded IX column outlet pH of >6 during the first 6 h of run during which [Gd] decreased from 2.1 to 1 mg/kg. However, the main moderator system pH was between 5.0-5.5. Technical specification for pH of moderator is in the range 5.0-5.5 as long as Gd is present. This is to avoid any precipitation of Gd in the core and a pH of 5.8 or even a pH of 5.6 when carbonate is present is specified as the upper limit of the moderator system pH for this purpose. The situation of IX column outlet pH being #>=# 6 mixing with a system water having Gd results in local mixing zone pH in the range of 6- 5.4. In order to have an iso-pH regime (5-5.5) both with respect to the IX outlet as well as in the system, studies were conducted to modify IX resin composition. Use of ...
2005-11-01
Measurement of K x-ray intensity ratio of tin, gadolinium and dysprosium
International Nuclear Information System (INIS)
Full text: Measurement of K_#beta# to K_#alpha# x-ray intensity ratios are important not only in the field of atomic physics, radiation physics and medical physics, but also to test the validity of assumptions made in the theoretical prediction. The intensity ratios can also give information on the effect of physical and chemical environment of the element in the compound. Many investigators have adopted a single and double reflection geometries to measure the K_#beta# to K_#alpha# x ray intensity ratios to understand the effect of physical and chemical environment on x-ray fluorescence. The targets are excited by a radioactive source of having activity of the order 100 MBq. in order to carry out accurate measurement K_#beta# to K_#alpha# x-ray intensity ratios, we have develop 2#pi# geometrical configuration method : placing a target right on the surface of the detector facing the target to measure the K shell fluorescence parameters such as fluorescence yield, fluorescence cross ...
2003-11-01
Hilar cholangiocarcinoma: MR correlation with surgical and histological findings
International Nuclear Information System (INIS)
Aim: To evaluate magnetic resonance cholangiography (MRC) with high-resolution dynamic gadolinium-enhanced magnetic resonance imaging (MRI) in determining the imaging features of hilar cholangiocarcinoma that relate to tumour extent and influence resectability. Materials and methods: Twenty-six patients that underwent resection were reviewed. Tumour location and extent, lobar atrophy, the degree of portal vein and hepatic artery involvement were recorded. The findings were correlated with surgical and histopathological findings. Results: Biliary assessment was concordant in 14 and discordant in eight of 14 stented and four of 12 non-stented patients. In 63/82 veins and 43/74 arteries results were fully concordant. The mean sensitivity, specificity, positive and negative predictive values (PPV, NPV) in predicting involvement of the main portal vein (MPV) at surgery were 83.3, 100, 100, and 92.5%; of the left main branch of the portal vein (LPV) were 100, 91.6, 93.3, ...
2010-10-01
A large surface neutron and photon detector for civil security applications
Energy Technology Data Exchange (ETDEWEB)
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by few-millimeter-thick lead ...
2010-05-21
A large surface neutron and photon detector for civil security applications
International Nuclear Information System (INIS)
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by few-millimeter-thick lead ...
2010-05-11
Thermal-neutron capture cross section and resonance integral of americium-241
International Nuclear Information System (INIS)
The thermal-neutron capture cross section (#sigma#_0_,_g) and the resonance integral (I_0_,_g) leading to the ground state of "2"4"2Am were measured by an activation method for neutron capture by "2"4"1Am. A method with gadolinium, which was similar to the cadmium difference method, was used to measure the cross section #sigma#_0_,_g with attention to resonances of "2"4"1Am. Americium chloride samples containing "2"4"1Am radioisotope were irradiated for 68 h in the long-irradiation plug of the Kyoto University Research Reactor, KUR. Wires of Co/Al and Au/Al alloys were used as monitors to determine thermal-neutron fluxes and epithermal Westcott's indexes at the irradiation positions. An #alpha#-ray spectrometer was used to measure the activity ratios of "2"4"2Cm to "2"4"1Am. On the basis of Westcott's convention, the #sigma#_0_,_g and I_0_,_g values were determined as 628#+-#22 b and 3.5#+-#0.3 kb, respectively. (author)
2007-12-01
Structural and magnetic properties of barium-gadolinium hexaferrites
Energy Technology Data Exchange (ETDEWEB)
A series of Gd-substituted M-type barium hexaferrites has been prepared by the ceramic route, according to the formula (Ba{sub 1-x}Gd{sub x})O.5.25Fe{sub 2}O{sub 3} (x=0-0.30). XRD analysis revealed that all the samples present primarily an M-type structure. Samples x=0 and x=0.05 are single-phase. Hematite (Fe{sub 2}O{sub 3}) and GdFeO{sub 3} were detected in the remaining samples. Coercivity (H{sub c}) shows remarkably high values, {approx}293kA/m for x=0.20 and 0.30 with a maximum of 322kA/m for x=0.25. Specific saturation magnetization ({sigma}{sub sat}) of the samples presents a small increase up to x=0.10. The microstructure examination indicates that Gd may act as a grain growth inhibitor.
2007-03-15
Structural and magnetic properties of barium-gadolinium hexaferrites
International Nuclear Information System (INIS)
A series of Gd-substituted M-type barium hexaferrites has been prepared by the ceramic route, according to the formula (Ba_1_-_xGd_x)O.5.25Fe_2O_3 (x=0-0.30). XRD analysis revealed that all the samples present primarily an M-type structure. Samples x=0 and x=0.05 are single-phase. Hematite (Fe_2O_3) and GdFeO_3 were detected in the remaining samples. Coercivity (H_c) shows remarkably high values, #approx#293kA/m for x=0.20 and 0.30 with a maximum of 322kA/m for x=0.25. Specific saturation magnetization (#sigma#_s_a_t) of the samples presents a small increase up to x=0.10. The microstructure examination indicates that Gd may act as a grain growth inhibitor.
2007-03-01
Regulatory review of reactor physics design aspects of TAPP-3 and 4
International Nuclear Information System (INIS)
Atomic Energy Regulatory Board carries out the regulatory review of the reactor physics design, commissioning and operational aspects through Project Design Safety Committee and Specialist Group of reactor physicists with wide experience in the design, commissioning and operational safety review of NPPs. TAPP-3 and 4 PHWRs, being the first indigenous design of 540 MWe Units, are quite different than the standard 220 MWe PHWRs. The safety review of reactor physics design was quite complex, as majority of the systems were new. The Reactor Physics Specialist Group carried out extensive safety review of 540 MWe PHWR reactor physics design and made significant contributions of design modifications and improvements in the operational procedures. Some salient contributions include: Monitoring the core during bulk addition of moderator without the availability of shutdown systems. Logics for providing safety cover in case of malfunction of SDS-1, Use of Gadolinium, ...
2006-11-13
Monte-Carlo-based simulation of LWR cores with innovative fuel concepts
International Nuclear Information System (INIS)
High resolution Monte-Carlo simulations show that the neutron spectrum, fuel burnup and fuel temperature feedback effect of a PWR core loaded with Thoria-based fuel (Th/Pu-O_2) do not significantly differ from the MOX fuelled one due to the similar neutronic characteristics of both fertile materials (Th-232, U-238). The core physics of this fuel variant is characterized by an enhanced moderator/void temperature coefficient (by factor 2.4) and high incineration rate for Pu (approx. 60 %). A PWR core loaded with the Molybdenum-based inert matrix fuel (IMF) - in contrast to MOX-, shows a harder spectrum, resulting in small temperature coefficients of reactivity and particularly in a higher fuel depletion rate as well as an enhanced TRU reduction performance. The incineration of Pu amounts to 46 % resulting, in turn, in generation of minor actinides of about 10 % of the total Pu consumption. The higher excess reactivity resulting from the initial Pu contents is controlled by the use of ...
2009-05-03
Energy Technology Data Exchange (ETDEWEB)
Magnetic resonance imaging (MRI) has rapidly attained a major position among the examinations used in the diagnostic approach of multiple sclerosis because it is highly sensitive in demonstrating lesions. However, these lesional images may have several meanings, and there is the problem of distinguishing between oedema, which is said to reflect recent lesions, and gliosis which is thought to betray old lesions. The intrinsic MRI parameters studied (i.e. relaxation times) are unable to make this distinction, whereas it is provided by paramagnetic contrast media such as gadolinium. There is no correlation between the changes observed at MRI and the severity of the disease. Another problem is the accuracy of lesion localization, since visualization is predominantly macroscopic. This raises several questions about the demonstration of correlations between clinical signs and site of the lesion(s). At the moment, several teams of neuroradiologists are trying to find the ...
1991-09-15
Magnetic moment measurements of gadolinium, holmium and ytterbium tartrate trihydrate crystals
British Library Electronic Table of Contents (United Kingdom)
Magnetic moment and susceptibility of single crystals of rare earth tartrates of the type R(C4H4O6)(C4H5O6)3H2O (where R = Gd, Ho, and Yb), using a vibration sample magnetometer are reported. The experimental values of molar susceptibilities for Gd(C4H4O6)(C4H5O6)3H2O, Ho(C4H4O6)(C4H5O6)3H2O, and Yb(C4H4O6)(C4H5O6)3H2O are 2.58x10-2, 4.66x10-2, and 8.03x10-3 (in cgs em units), respectively. The calculated effective magnetic moments are in good agreement with the theoretical predictions on rare earth ions.
2008-01-01
Energy Technology Data Exchange (ETDEWEB)
This work concerns the study of the nuclear superdeformation phenomenon in the rare earth region (A {approx} 150). The superdeformed (SD) states in Gadolinium and Dysprosium isotopes were produced via heavy-ion induced reactions and studied with the (EUROGAM EUROpean GAmma-ray Microscope) gamma multidetector array. Precise level attenuation method (DSAM). From the derived quadrupole moments, we find large differences in deformation between the yrast bands in neighbour nuclei explained in terms of the case of nuclei corresponding to an axis ratio of 2:1, the shell gaps are not fixed at a specific particle number and deformation. Furthermore the present results indicate that the deformations associated with identical bands are different supporting the picture that mass and deformation changes tend to compensate in SB bands with the same moments of inertia. (author). 114 refs.
1996-05-13
British Library Electronic Table of Contents (United Kingdom)
This study examined the oxygen permeation behavior of Ce0.9Gd0.1O2-d (Gadolinium-Doped Ceria, GDC)/Ba0.5Sr0.5Co0.8Fe0.2O3-d (BSCF) composite membranes fabricated using a conventional sintering technique. GDC/BSCF composite membranes with a relative density >95% could be obtained when a green compact of BSCF and GDC was sintered at 1150^oC for 5h. It appears that GDC serves as a grain growth inhibitor because the average grain size of the composite decreased with increasing GDC content. The oxygen permeability of the BSCF and GDC/BSCF composite membranes strongly depends on the grain size and membrane thickness. The addition of GDC to BSCF resulted in a small grain size, low thermal expansion coefficient and high hardness. However, it is believed that oxygen permeation was blocked by GDC, a...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
Monoclonal antibodies (MAbs) 19-9 and 73-3 specific for human colon adenocarcinoma were labelled with a high number of gadolinium atoms. Twenty five DTPA were chelated per MAb, with only slight loss of immunoreactivity. The NMR contrast agent Gd-25 DTPA-MAb 19-9 or 73-3 ((Gd) 17 mumole/kg, (MAb) 60 microM) was injected into nude mice bearing human colon adenocarcinoma (SW948). Tumors were removed 24 hr after injection and T1 was measured in vitro. T1 relaxation time varied according to MAb specificity against tumour targets; T1 decreased 20% for MAb 19-9 and MAb 73-3 with SW948 tumor. Imaging was performed with this model. Very good contrast was obtained 24 hr after Gd-25 DTPA-MAb injection.
1988-01-01
Ganglioneuromas in childhood: MRI and CT characteristics
International Nuclear Information System (INIS)
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T_1-weighted scans the tumors were homogeneous and hypointense, after ...
2000-05-01
Dura thickening adjacent to intracranial tumors on MRI. Histologically correlation
International Nuclear Information System (INIS)
Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T_2-weighted spin echo (SE) images as well as T_1-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base also showed tumor invasion ...
Energy Technology Data Exchange (ETDEWEB)
In a previous survey we revealed uncertainty among responders about (a) whether or not to perform hemodialysis in patients with severely reduced renal function who had received contrast medium; and (b) when to perform hemodialysis in patients on regular treatment with hemodialysis or continuous ambulatory dialysis who received contrast medium. Therefore, the Contrast Media Safety Committee of The European Society of Urogenital Radiology decided to review the literature and to issue guidelines. The committee performed a Medline search. Based on this, a report and guidelines were prepared. The report was discussed at the Ninth European Symposium on Urogenital Radiology in Genoa, Italy. Hemodialysis and peritoneal dialysis safely remove both iodinated and gadolinium-based contrast media. The effectiveness of hemodialysis depends on many factors including blood and dialysate flow rate, permeability of dialysis membrane, duration of hemodialysis and molecular size, ...
2002-12-01
Assessment of PET and MRI Polar Map using Gaussian Mixture Model
International Nuclear Information System (INIS)
Cardiac disease research relies increasingly on small animal models and non-invasive imaging methods such as positron emission tomography (PET) and magnetic resonance imaging (MRI). Delayed enhancement magnetic resonance imaging (DE-MRI) using gadolinium-based contrast agents appear to be a visualizing infracted myocardium with high spatial resolution. Polar map (or bull's-eye image) was used to determination of the myocardial infarction area. Polar map is a comprehensive interpretation of the left ventricle. The infarct size was computed as the fraction of the total polar map areas. The threshold was computed as the percentage of mean intensity of the normal region. In other study, 50% predefined threshold value in varying range (30?70%) was most commonly use. However, predefined threshold value isn't acceptance in all case. The purpose of this study was to investigate methodological approach for automatic measurement of rat myocardial infarct size using PET and ...
2010-10-01
Energy Technology Data Exchange (ETDEWEB)
The optical absorption of the Tm{sup 3+} ion in the gadolinium oxychloride (GdOCl) matrix in the UV, visible, and NIR range was studied at temperatures between 9 and 300 K. The visible luminescence of GdOCl:Tm{sup 3+} under Ar{sup +} ion laser and mercury lamp excitation was recorded at 9, 77, and 300 K, too. The crystal field (CF) splitting of the {sup 3}H{sub 4-6}, {sup 3}F{sub 2-4}, {sup 1}G{sub 4}, {sup 1}D{sub 2}, and {sup 1}I{sub 6} levels of the Tm{sup 3+} ion deduced from the spectra was analysed according to the C{sub 4v} point symmetry of the RE{sup 3+} site. The resulting energy level scheme, consisting of 39 levels (i.e. 55 Stark components) out of the total of 70 (91) for the whole 4f{sup 12} configuration, was simulated with the aid of a phenomenological theory taking simultaneously into account both the free-ion and CF effects. The model included 13 adjustable parameters describing the electrostatic (the Racah parameters E{sub 0-3}) and the ...
1995-06-26
Energy Technology Data Exchange (ETDEWEB)
Purpose: `Exoscopic` and endoscopic identification of colorectal pathologies via MRI. Methods: 5 patients (36-88 years), two normal and three with different colorectal pathologies (diverticular disease, polyps and carcinoma of the colon), were examined by MRI after colonoscopy. Subsequent to filling of the colon with a gadolinium-water mixture under MRI-monitoring, 3D-data sets of the colon were acquired in prone and supine positions over a 28 sec breathold interval. Subsequently multiplanar T{sub 1}-weighted 2D-sequences were acquired before and following i.v. administration of Gd-DTPA (0.1 mmol/kg BW). All imaging was performed in the coronal orientation. The 3D-data were interactively analysed based on various displays: Maximum intensity projection (MIP), surface shadowed display (SSD), multiplanar reconstruction (MPR), virtual colonoscopy (VC). Results: All of the colorectal pathologies could be interactively diagnosed by MPR. On MIP images some pathologies ...
1997-09-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: With intracranial tumors a flat, contrast-enhancing, probably dural structure adjacent to the tumor can occasionally be observed on gadolinium-DTPA enhanced MR images. Therefore we have attempted to evaluate a tumor infiltration of this enthancement on MRI. Material and Methods: This study included 50 patients. 19 patients had a dural thickening at the tumor base (13 meningiomas and 6 metastases), while 31 patients did not (12 meningiomas and 19 metastases). Studies included plane T{sub 2}-weighted spin echo (SE) images as well as T{sub 1}-weighted axial, coronal, or sagittal plains with and without contrast agent. Histopathological examinations, were done on the tumor base adjacent to the dura mater. Results: 7 of 12 meningiomas showed a meningeal thickening on MRI with histopathologically proven tumor infiltration as did also 5 of 6 metastases. But 3 of 12 meningiomas and 15 of 19 metastases without dural thickening at the tumor base also showed tumor ...
1997-11-01
Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging
Energy Technology Data Exchange (ETDEWEB)
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new neutron beamport facility, with a larger neutron flux (7.3 x 10[sup 7] n/cm[sup 2]/s) than the previous facility was constructed. A ...
1992-01-01
International Nuclear Information System (INIS)
Addition of Gadolinium Nitrate as chemical shim to moderator heavy water of 540 MWe PHWR, at 15 mg/kg level (at a pH of 5.0) is practiced for reactor shutdown purposes. Presently a strong acid cation exchanger column is used for this purpose. During this operation, the moderator pH of 3.8, with the IX column outlet pH of ?3.5-3.6 was observed against the technical specification demand that when Gd is present, the pH of moderator must be in the range of 5.0-5.5. In order to achieve an iso-pH regime during Gd removal, studies were conducted using a mixed bed of strong acid cation resin plus a weak base anion resin (loaded in the volume ratio of 1 : 6), backed up in the same column (bottom most layer) by a 5 % nitric acid loaded weak base resin and topped by a strong acid cation resin (uppermost layer) simulating system flow velocity and percentage loading of resin. Using such a column it is demonstrated that Gd removal could be achieved simultaneously maintaining the ...
2006-11-13
Energy Technology Data Exchange (ETDEWEB)
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios. The measured relative K/sub ..beta..//K/sub ..cap alpha../ X-ray intensity ratios were compared to the calculated values predicted by the theoretical development of Scofield and the average of previous ...
1987-01-01
International Nuclear Information System (INIS)
The effect that different chemical and physical atomic environments can have on the relative intensities of radiative electron transitions from the filling of K shell vacancies was investigated. The method used involved the detection of photoionization induced X-ray fluorescence. An experimental system based on a hyper pure germanium detector (HPGE) was used to measure the relative K-L and K-M X-ray yields from the photofluorescence of a series of lanthanide elements and compounds. A background subtraction and peak integration strategy was employed which accounted for scattering in the samples and scattering of the flux from the radioisotope photoionization sources. Analysis of the data resulted in a tabulation of relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios. The measured relative K/sub #beta#//K/sub #alpha#/ X-ray intensity ratios were compared to the calculated values predicted by the theoretical development of Scofield and the average of previous experimental values ...
1987-01-01
Gadolinium removal from the moderator system of TAPP - 3 using the three layer bed
International Nuclear Information System (INIS)
Nitric acid leaching from the weak base anion (WBA) exchanger had been evaluated and based on this a 5% mixture of nitric acid loaded weak base anion exchanger with fresh weak base anion exchanger (NLWBA) at the bottom of the ion exchange column has been devised to maintain an outlet pH in the range of 5.0 to 5.5 during Gd removal from the moderator system of TAPP - 3 and 4. A three layered bed had been constituted wherein strong acid cation (SAC) exchanger is placed as the top layer while a mixed bed of SAC and WBA or pure WBA is used as the middle layer and the 5% NLWBA was used as the bottom most layer. This bed configuration would result in an iso-pH regime in the moderator system during the Gd removal along with quantitative removal of Gd. Two three-layer bed columns were prepared at TAPS - 3 and 4 in July 07. The resin was loaded in batches and after preparing the column, the column was deuterated with heavy water (> 99.75 % w/w) at a steady flow rate of 280 ml/min. After ...
2008-12-01
Energy Technology Data Exchange (ETDEWEB)
Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 dogs in 3 groups were exposed to radiation: 19 were exposed in the gamma group at 0.75 Gy/min, 20 were exposed in the undrugged neutron group at 1.62 ...
1985-08-01
Energy Technology Data Exchange (ETDEWEB)
The aim of this work was to develop a method to distinguish between different ion formation processes and to determine the influence of these processes on the total number of detected monatomic ions of a certain element. A vector/matrix-formalism was developed, which describes the physical processes of sputtering, ion formation, mass separation and detection in laser-SNMS. In the framework of the method developed, based on this theoretic formalism, changes in the secondary flux contribution of the respective element were observed by comparing the detected monatomic ion yield obtained in specifically aligned (SIMS and) laser-SNMS experiments. The yields resulting from these experiments were used to calculate characteristic numbers to compare the flux composition from different surfaces. The potential of the method was demonstrated for the elements boron, iron and gadolinium by investigating the changes in the flux composition of secondary particles sputtered from ...
2008-10-13
Comparative study of the crystal field effects in rare earth oxynitrates
Energy Technology Data Exchange (ETDEWEB)
The photoluminescence spectra of the lanthanum and gadolinium oxynitrates doped with Eu[sup 3+], REONO[sub 3]:Eu[sup 3+] (RE=La and Gd) were measured at 77 and 300 K. The [sup 7]F[sub J] (J=0-5) energy level schemes for the 4f [sup 6] electron configuration were simulated by a C[sub 2v] phenomenological crystal field (CF). The nine non-zero CF parameters for the C[sub 2v] site symmetry reproduce the experimental energy level schemes with rms deviations of 7 and 5 cm[sup -1] for the LaONO[sub 3] and GdONO[sub 3] hosts, respectively. The CF effect is stronger in the lanthanum host although otherwise the CF parameters for the two oxynitrate hosts differ only slightly. The B[sup k][sub 2] (k=2, 4 and 6) values are low indicating only a slight deviation from a higher C[sub 4v] symmetry. The B[sup 2][sub 0], B[sup 4][sub 0] and B[sup 4][sub 4] parameters assume high values which are similar to those obtained previously for the other RE oxy compounds, i.e. oxyhalides, ...
1994-06-01
Commissioning and operation of new liquid poison injection based shut down system in TAPP-3 and 4
International Nuclear Information System (INIS)
Shut Down System - 2 (SDS - 2) of TAPP-3 and 4 works on the principle of rapid injection of gadolinium nitrate poison solution into bulk moderator in calandria using high pressure helium to shut down the reactor. This is a new system, in the context of Indian PHWRs, designed, engineered, commissioned and being operated in TAPP-3 and 4. The system design incorporates passive features such as floating polyethylene ball with ball-ball seat arrangement and locked open isolation ball valves with key interlock arrangement. This arrangement eliminates active valves downstream of poison tanks during SDS - 2 actuation. A series parallel arrangement of fast acting pilot controlled air operated valves, which keep the high pressure helium isolated from poison tanks in poised state, are the only active components. During commissioning and initial period of operation of TAPP-4, problems were encountered and were resolved by suitable modifications and the same were incorporated ...
2006-11-13
A comparison of x-ray detectors for mouse CT imaging
International Nuclear Information System (INIS)
There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum efficiency (DQE), stability over multiple exposures, and noise in reconstructed CT images. The a-Se ...
2004-12-07
Energy Technology Data Exchange (ETDEWEB)
The aim of this study is three folds: to compare the eight-channel phased-array and standard circularly polarized (CP) head coils in visualiazation of the intracranial vessels, to compare the three-dimentional (3D) time-of-flight (TOF) MR angiography (MRA) techniques, and to define the effects of parallel imaging in 3D TOF MRA. Fifteen healthy volunteers underwent 3D TOF MRA of the intracranial vessels using eight-channel phased-array and CP standard head coils. The following MRA techniques were obtained on each volunteer: (1) conventional 3D TOF MRA with magnetization transfer; (2) 3D TOF MRA with water excitation for background suppression; and (3) low-dose (0.5 ml) gadolinium-enhanced 3D TOF MRA with water excitation. Results are demonstrating that water excitation is a valuable background suppression technique, especially when applied with an eight-channel phased-array head coil. For central and proximal portions of the intracranial arteries, unenhanced TOF MRA ...
2004-11-01
Energy Technology Data Exchange (ETDEWEB)
We report on a recent search for {bar {nu}}{sub e} appearance from stopped {pi}{sup +} {yields} {mu}{sup +}{nu}{sub {mu}} and {mu}{sup +} {yields} e{sup +}{nu}{sub e}{bar {nu}}{sub {mu}} decay made by the LAMPF experiment E645. The appearance of {bar {nu}}{sub e} may occur from {bar {nu}}{sub {mu}} {yields} {bar {nu}}{sub e}, {nu}{sub e} {yields} {bar {nu}}{sub eL}, or {nu}{sub {mu}} {yields} {bar {nu}}{sub eL} oscillations. Appearance may also occur from rare {mu}{sup +} {yields} e{sup +}{bar {nu}}{sub e}{nu}{sub {mu}} decay, which is allowed by a multiplicative lepton charge conservation law. The neutrino energies range from E{sub {nu}} = 0 to 52.8MeV. The neutrino detector, which is located 26.1 meters from the neutrino source, consists of a segmented liquid scintillator and proportional drift tube central detector surrounded by both active and passive shielding. The central detector detects {bar {nu}}{sub e} through the {bar {nu}}{sub e}p {yields} ne{sup +} Charge Current (CC) ...
1990-01-01
Energy Technology Data Exchange (ETDEWEB)
Purpose: The aim of this study was to demonstrate the typical appearance of ganglioneuromas in computer-assisted tomography (CT), and magnetic resonance imaging (MRI). Material and methods: Retrospective analysis of diagnostic imaging (9 CT, 6 MRI) in 9 children aged 3 to 15 years with the histological diagnosis of ganglioneuroma. Results: The tomographies showed large (max. 13.4 cm in diameter) round or oval tumors with sharp delineation. The sites of the tumors were the retroperitoneum (5), the mediastinum (3), and the adrenal gland (1). Intraspinal tumor involvement occurred in 4 cases. On comparing CT with MRI, MRI was more accurate in defining the intraspinal involvement. The ganglioneuromas were of hypodense appearance in the native CT scan and showed moderate enhancement upon administration of contrast media. In five patients tumor calcifications with a disseminated sprinkled pattern were seen in CT. In MRI T{sub 1}-weighted scans the tumors were homogeneous and hypointense, ...
2000-05-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
