GaAs detector optimization for different medical imaging applications  

International Nuclear Information System (INIS)

We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)

1999-09-11

2

Deep-level defects and numerical simulation of radiation damage in GaAs solar cells  

Energy Technology Data Exchange (ETDEWEB)

A review of the deep-level defects observed in both electron- and proton-irradiated GaAs solar cells is presented. Studies of the effects of periodic and continuous thermal annealing on the radiation-induced electron and hole traps and the recombination parameters in GaAs solar cells were made for a wide range of electron and proton energies, fluence, annealing temperature and annealing time. A refined model for numerical simulations of the displacement damage was developed for computing the defect density and the cell parameters in the electron- and proton-irradiated GaAs solar cells. Excellent agreement was obtained between the calculated values and the experimental data for the proton-irradiated GaAs solar cells. (orig.).

1991-09-01

3

Phase formation sequence in the Pd-GaAs system  

Energy Technology Data Exchange (ETDEWEB)

The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.

1985-12-01

4

The Use of Medical Images in Planning and Delivery of Radiation Therapy  

UK PubMed Central (United Kingdom)

Abstract The authors provide a survey of how images are used in radiation therapy to improve the precision of radiation therapy plans, and delivery of radiation treatment. In contrast...Full Text Available

1997-09-01

5

A final report for: Gallium arsenide P-I-N detectors for high-sensitivity imaging of thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal ...

1999-04-01

6

GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy  

Energy Technology Data Exchange (ETDEWEB)

High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction in the low-temperature dark current compared to the absorbing ...

2004-12-21

7

Radiation tolerant GaAs MESFET with a highly-doped thin active layer grown by OMVPE  

International Nuclear Information System (INIS)

A new structure of GaAs MESFET with high radiation tolerance is proposed. Changes in electrical parameters of a GaAs MESFET as a function of total #gamma#-ray dose have been found to be caused mainly by a decrease in the effective carrier concentration in an active layer. The authors have designed a new structure from a simulation based on an empirical relationship between the changes of the effective carrier concentration and the total #gamma#-ray dose. It has been successfully demonstrated by utilizing a highly-doped thin active layer (4 x 10"1"8 cm"-"3, 100 Angstrom) grown by OMVPE. This MESFET can withstand a dose ten times higher [1 x 10"9 rads(GaAs)] than a conventional one can.

1990-07-16

8

Metastable one- and two-electron donor states in GaAs and CdF{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The strongly localized one-electron (D{sup 0}) and two-electron (D{sup -}) donor states are considered with the lattice deformation around the donor center taken into account. For GaAs, donor energy levels have been calculated as functions of the hydrostatic pressure. The calculated energy positions and pressure coefficients agree with the experimental data. It is shown that the interaction with phonons reduces the probability of radiative transitions between the states of different localization and leads to the metastability of shallow-level donor states with respect to the D{sup -} state in GaAs and both the states (D{sup 0} and D{sup -}) in CdF{sub 2}. (author) 7 refs, 1 fig

1996-12-31

9

The importance of radiation quality for optimisation in radiology  

UK PubMed Central (United Kingdom)

Selection of the appropriate radiation quality is an important aspect of optimisation for every clinical imaging task in radiology, since it affects both image quality and patient dose. Spreadsheet...Full Text Available

10

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had a threshold voltage of 0.17V, an off-state leakage current of ...

2002-01-01

12

Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy  

UK PubMed Central (United Kingdom)

Adaptive radiation therapy (ART) is the incorporation of daily images in the radiotherapy treatment process so that the treatment plan can be evaluated and modified to maximize the amount of radiation...Full Text Available

2009-01-01

13

Electrical properties of inalp native oxides for metal-oxide-semiconductor device applications  

Science.gov (United States)

Data are presented on the insulating properties and capacitance-voltage (CV) characteristics of metal-oxide-semiconductor (MOS) device-thickness (below approx. 100 nm) native oxides formed by wet thermal oxidation of thin InAlP epilayers lattice matched to GaAs. Low leakage current densities of J=1.4 x 10-9 A/cm2 and J=8.7 x 10-11 A/cm2 are observed at an applied field of 1 MV/cm for MOS capacitors fabricated with 17 nm and 48 nm oxides, respectively. TEM images show that the In-rich interfacial particles which exist in 110 nm oxides are absent in 17 nm oxide films. Quasi-static capacitance-voltage measurements of MOS capacitors fabricated on both n-type and p-type GaAs show that the InAlP oxide-GaAs interface is sufficiently free of traps to support inversion, indicating an unpinned Fermi level. These data suggest that InAlP native oxides may be a viable insulator for GaAs MOS device applications.

2004-09-01

14

X-ray imaging dose due to the digital imaging devices used in radiation therapy for patient positioning and repositioning: How to take it into account?; Les doses dues a l'imagerie numerique pour le controle de positionnement du patient en radiotherapie: comment les prendre en compte?  

Energy Technology Data Exchange (ETDEWEB)

The patient positioning and repositioning control in radiation therapy all along the treatment can be conducted using a variety of X-ray sources and imaging detector devices. The development of image guided radiation therapy techniques leads to more frequent use of this imaging control. In this article we summarize the current methods for measuring the dose delivered by X-ray imaging devices used in radiation therapy, as well as basic proposals to take account of these imaging doses for prescribing, recording and reporting radiation therapy treatment. (authors)

2008-12-15

15

High-efficiency GaAs solar cells  

Energy Technology Data Exchange (ETDEWEB)

An updated review of the state of the art in the development of GaAs solar cells is provided, with emphasis on AlGaAs-GaAs cells suitable for space applications. A set of theoretically derived characteristics is given for this type of solar cell. Comparison of measured performance with theory shows excellent agreement. Data on the effects of radiation damage (high-energy electrons, protons, and neutrons) is also integrated into a form useful for evaluation purposes. Techniques for fabricating (AlGa)As-GaAs solar cells in quantities large enough for practical applications are discussed and are shown to have been demonstrated. The possibility of extending these techniques to the fabrication of very thin low-weight cells for space applications is also considered. Finally, the results obtained to date in the development of GaAs solar cells for applications requiring concentrated sunlight are reviewed, for terrestrial as well as ...

1984-05-01

16

Model of quantum noise of shadow radiation images  

International Nuclear Information System (INIS)

Correlation characteristics of quantum noise on the shadow radiation image (RI) of the object under nondestructive testing are studied. Mathematical model of RI occasional distortions is derived. The model takes into account the parameters of object under testing and of radiation beam by radiation quanta flux density. The results obtained can be used as a component in the process of investigation of various radiation testing systems

18

Stereotactic Radiation Therapy for Brain Tumors  

Medline Plus

... acquired, which we then volumetrically fuse with the 3D image set from the MR. And by doing ...

21

Growth, Characterization and Device Development in ...  

Science.gov (United States)

... eV. In some instances the spontaneous radiation from a free electron laser system was employed to obtain images. The ...

1998-03-01

22

A BPF-FBP tandem algorithm for image reconstruction in reverse helical cone-beam CT  

UK PubMed Central (United Kingdom)

Purpose: Reverse helical cone-beam computed tomography (CBCT) is a scanning configuration for potential applications in image-guided radiation therapy in which an accurate anatomic image...Full Text Available

2010-01-01

23

Radiation doses in adults and children in standardized diagnostic radiology  

International Nuclear Information System (INIS)

For comparison of radiation exposure and risk in different diagnostic procedures for adults and children dose measurements and calculations of organs with special risk were carried out. Parameters of image formation influencing image quality as well as of exposure concerning infants and children are recorded and discussed as to radiation exposure and protection. Conclusions are drawn with respect to systems of image formation and to standards of examination and quality assurance.

1987-01-01

24

The influence of stray radiation on image quality  

International Nuclear Information System (INIS)

The present state of knowledge on the influence of stray radiation on image quality and its physical description and quantification is summarized. Experimental results on the influence of physical parameters on the fraction of scattered radiation and the effect of scatter reduction by air gap technique and secondary radiation grids are committed. Open theoretical and practical problems and the limitations of common methods of scatter reduction are pointed out. (author).

25

Scattered radiation effect on the defect image in high-energy bremsstrahlung introscopy  

International Nuclear Information System (INIS)

Results of the evaluation of the scattered radiation effect on the image of defects in examined products are given. The formula is suggested which characterizes the image of defects on a scintillation screen as well as accumulation factors are calculated by the Monte-Carlo method. Values of fluctuations of absorbed energy in the screen used for the evaluation of sensitivity are experimentally obtained. The effect of high-energy bremsstrahlung on the defect detection is analyzed.

26

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

1988-02-23

27

The influence of scattered radiation on recording systems and quality-assurance test parameters  

International Nuclear Information System (INIS)

Scattered radiation generated in patient and imaging system has to be considered when quality-assurance tests involve dose detection or image-quality estimations. Measurement of automatic-exposure control dose can be altered by backscattering from intensifying screens of more than 10% and the equipment transmission factor can be overestimated up to a factor of 10 when only primary radiation is used. The sensitivity of intensifying screens depends on the angle of incidence of the radiation and so primary and scattered radiation are detected differently. The quality-control aspects of anti-scatter grids are discussed. (author).

28

Future of X-ray phase imaging in medical imaging technology  

International Nuclear Information System (INIS)

Weakly absorbing materials, such as biological, soft tissues, can be imaged by generating contrast due to the phase shift of X-rays. In the past decade, several methods for X-ray phase imaging were proposed and demonstrated. The performance of X-ray phase imaging is attractive in the field of medical imaging technology, and its development for practical use is expected. Many methods, however, have been developed under the assumption of the use of synchrotron radiation, which is an obstacle to practical use. The method based on Talbot (-Lau) interferometry enables us to use a compact X-ray source, and its development is expected as a breakthrough for medical applications. (author)

2007-04-01

29

Point defects in dilute nitride III-N-As and III-N-P  

International Nuclear Information System (INIS)

We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.

2006-04-01

30

Introduction to Three Dimensional Reconstruction of Brain C. T. Image  

International Nuclear Information System (INIS)

The reconstruction of coronal and Sagittal Image of Brain C. T. is helpful to diagnosis of Brain. Three Dimensional Reconstruction software package allows to display three dimensional Image clerived from a series of Horizontal, Sagittal and Coronal Brain C. T. images. It useful in determine approach of operation, to define portals of deep radiation therapy.

1986-11-01

31

On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function  

UK PubMed Central (United Kingdom)

Voxel-based prescriptions of deliberately non-uniform dose distributions based on molecular imaging, so-called dose painting or theragnostic radiation therapy, require specification of a transformation...Full Text Available

2009-03-21

32

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the ...

2007-01-01

33

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

34

CR portal imaging; A linac graphy using storage phosphor imaging systems  

Energy Technology Data Exchange (ETDEWEB)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-07-01

35

Native Synthetic Imaging of Smoothed Particle Hydrodynamics density fields using gridless Monte Carlo Radiative Transfer  

CERN Document Server

An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework ...

2010-01-01

36

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

37

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

38

Multichannel radiometric inspection systems with half-tone visualization of radiation shadow images. 1. Mathematical model  

International Nuclear Information System (INIS)

A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the ...

40

Image Smearing in a Quantum Well Infrared Photodetector ...  

Science.gov (United States)

... Assuming isotropic emission, the 25' half angle cone represents only -9% [= 1/(2(ngaas/nopticglue) 2)] of the spontaneous radiation. ...

1998-12-01

41

Fractionated stereotactic radiotherapy in the treatment of pituitary macroadenomas  

UK PubMed Central (United Kingdom)

BackgroundThe use of fractionated stereotactic radiotherapy (fsrt) has evolved with technical advances in noninvasive immobilization, radiation delivery, and image guidance....Full Text Available

2008-12-01

42

Implementation of improved interactive image analysis at the Advanced Photon Source (APC) linac.  

Energy Technology Data Exchange (ETDEWEB)

An image-analysis system, based on commercially available data visualization software (IDL [1]), allows convenient interaction with image data while still providing calculated beam parameters at a rate of up to 2 Hz. Image data are transferred from the IOC to the workstation via EPICS [2] channel access. A custom EPICS record was created in order to overcome the channel access limit of 16k bytes per array. The user can conveniently calibrate optical transition radiation (OTR) and fluorescent screens, capture background images, acquire and average a series of images, and specify several other filtering and viewing options. The images can be saved in either IDL format or APS-standard format (SDDS [3]), allowing for rapid postprocessing of image data by numerous other software tools.

1998-09-11

43

Image-based modeling of tumor shrinkage in head and neck radiation therapy1  

UK PubMed Central (United Kingdom)

Purpose: Understanding the kinetics of tumor growth∕shrinkage represents a critical step in quantitative assessment of therapeutics and realization of adaptive radiation therapy....Full Text Available

2010-05-01

44

A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy  

UK PubMed Central (United Kingdom)

In many radiotherapy clinics, geometric uncertainties in the delivery of 3D conformal radiation therapy and intensity modulated radiation therapy of the prostate are reduced by aligning the...Full Text Available

2007-07-01

45

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are ...

1996-01-01

46

CR portal imaging  

International Nuclear Information System (INIS)

In portal images with high energy X-ray (10 MV), it is sometimes difficult to verify the irradiation field because of the low contrast. Especially, in the abdominal and pelvic region, the deterioration of portal image quality is remarkable. To solve this problem, we took portal images using computed radiography (FCR). Also, we develop a technique in which a copper plate (3 mm) and lead foil (0.3 mm) are closely set in the front and rear of the photostimulable phosphor plate (imaging plate), for increased energy absorption. As a result, image quality was very high and we confirmed image improvement using observer performance experiments. We made a special cassette which can closely set metallic plates to imaging plate and load FCR-7000 directly. Therefore, image process becomes simple, and suitable for routine work. In ...

1992-01-01

49

Dependence of impurity binding energy on nitrogen and indium concentrations for shallow donors in a GaInNAs/GaAs quantum well under intense laser field  

British Library Electronic Table of Contents (United Kingdom)

Within the framework of the effective-mass approximation, using a variational method, we have calculated the effect of intense laser radiation on the binding energy of the shallow-donor impurities in a Ga1- x In x N y As1- y /GaAs single quantum well for different nitrogen and indium mole concentrations. Our numerical results show that the binding energy strongly depends on the laser intensity and frequency (via the laser dressing parameter) and it also depends on the nitrogen and indium concentrations. Impurity binding energy under intense laser fields can be tuned by changing the nitrogen and indium mole fraction.

2011-01-01

50

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

51

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to ...

2002-03-01

52

Large intracranial vessel occlusive vasculopathy after radiation therapy in children: clinical features and usefulness of magnetic resonance imaging  

International Nuclear Information System (INIS)

Purpose: To assess the relationship between large intracranial vessel occlusive vasculopathy (vasculopathy) and radiation therapy, and to clarify the clinical efficacy of magnetic resonance (MR) imaging in the diagnosis and screening of the vasculopathy. Methods and Materials: We retrospectively evaluated the medical records and serial MR images for 32 pediatric patients, in whom radiation therapy had been given to fields including the circle of Willis and major cerebral arteries. All children had periodically undergone follow-up neurologic assessment and MR imaging examinations at Kanagawa Children's Medical Center for more than one year after radiation therapy (range 1.3-14 years). Patients who had not remained free of tumor progression up to the time of final evaluation were excluded. Results: Vasculopathy developed in 6 of 32 patients 2-13 years after ...

1997-05-01

53

Evaluation of the chest radiography using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Chest radiograms obtained by using Fuji Computed Radiography (FCR) system were compared to conventional film/screen radiograms. The FCR images showed better image quality in diagnostic information than the conventional chest images. In FCR, the radiation exposure to patient for chest examination could be reduced up to one tenths of conventional chest examination. The main advantages or FCR were considered to depend on the contrast processing and frequency processing properties. The use of FCR in clinical work may improve both diagnostic quality and radiation exposure.

1991-12-01

54

Combined Modality Treatment for Prostate Cancer With Dynamic Adaptive Radiation Therapy Using Four-Dimensional Image-Guided Intensity-Modulated Radiation Therapy and Brachytherapy  

British Library Electronic Table of Contents (United Kingdom)

Prostate cancer can be successfully treated using dynamic adaptive external beam radiation techniques along with interstitial brachytherapy to deliver curative therapies with low urinary, rectal and erectile function morbidity. Through the use of sophisticated, state-of-the art radiographic imaging for staging and treatment planning, a precise, individual design for treatment is accomplished. Symptom management and patient education are of paramount importance and are integrated throughout the treatment process.

2009-01-01

55

Real time neutron radioscopy - trends and applications  

International Nuclear Information System (INIS)

Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor

2003-11-12

56

Automated analysis of damages for radiation in plastics surfaces; Analisis automatizado de danos por radiacion en superficies plasticas  

Energy Technology Data Exchange (ETDEWEB)

Analysis of damages done by the radiation in a polymer characterized by optic properties of polished surfaces, of uniformity and chemical resistance that the acrylic; resistant until the 150 centigrade grades of temperature, and with an approximate weight of half of the glass. An objective of this work is the development of a method that analyze in automated form the superficial damages induced by radiation in plastic materials means an images analyst. (Author)

1990-02-15

57

Computed radiography. Evaluation of its role in the mass survey for lung cancer: Phantom study  

Energy Technology Data Exchange (ETDEWEB)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in ...

1987-12-01

58

Computed radiography  

International Nuclear Information System (INIS)

In an effort to evaluate the feasibility of introducing computed radiography (FCR) into mass screening for lung cancer, the ability of FCR to detect nodules one cm in diameter was examined using a humanoid chest phantom. Based on the receiver operating characteristic (ROC) analysis, the detectability of FCR was compared with that of conventional radiography and photofluorography. The values of area under ROC curves were higher for FCR (0.963 for image similar to that with conventional film-intensifying screen system, image A; and 0.952 for processed image, image B) than the other two methods (0.774 for radiography and 0.789 for photofluorography). Degradation of image quality in FCR could be avoided by a wide latitude even if proper exposure techniques might not be employed. Images A and B in FCR yielded excellent delineation for nodules in the lung field and in ...

1987-01-01

59

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

Energy Technology Data Exchange (ETDEWEB)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-05-01

60

The determination of optical conditions of Fuji computed radiography (FCR) in pelvimetry and the reduction of radiation dose to mother and fetus  

International Nuclear Information System (INIS)

The determination of optical parameter type in x-ray pelvimetry was performed on 59 subjects using Fuji computed radiography (FCR). Excellent measurable images were obtained at GT (type A), RT (type P), GA (1.6) and RN (2.0). To reduce maternal and fetal exposure to radiation, the doses were progressively decreased to 50%, 25%, 12.5%, 6.3%, that of conventional screen/film system. One-eighth per cent of conventional radiation dose was minimum for FCR at which measurable images could be obtained. Thereby drastically reducing the radiological exposure to both mother and fetus was possible to obtain measurable images in FCR. (author).

1991-01-01

61

Non-destructive Imaging of Individual Bio-Molecules  

CERN Document Server

Radiation damage is considered to be the major problem that still prevents imaging an individual biological molecule for structural analysis. So far, all known mapping techniques using sufficient short wave-length radiation, be it X-rays or high energy electrons, circumvent this problem by averaging over many molecules. Averaging, however, leaves conformational details uncovered. Even the anticipated use of ultra-short but extremely bright X-ray bursts of a Free Electron Laser shall afford averaging over 10^6 molecules to arrive at atomic resolution. Here we present direct experimental evidence for non-destructive imaging of individual DNA molecules. In fact, we show that DNA withstands coherent low energy electron radiation with deBroglie wavelength in the Angstrom regime despite a vast dose of 10^8 electrons/nm^2 accumulated over more than one hour.

2009-01-01

62

A study of the effects of scattered radiation on radiographic quality and methods of elimination of such radiation  

International Nuclear Information System (INIS)

Many mechanical parts are subjected to stresses and strains that may eventually lead to their failure. In order to prevent the costly delays associated with equipment down-time, many parts have to be tested for weaknesses and defects when machinery is constructed or dismantled for maintenance. These procedures are known as Non-Destructive Testing (NDT) methods. Five types of non-destructive testing methods routinely used are radiographic testing, ultrasonic testing, magnetic particle inspection, liquid penetrant testing and eddy current testing. Out of these five techniques industrial radiography plays an important role in non-destructive testing to reveal interior defects in materials. In radiography almost two-thirds of the radiation reaching the film is scattered radiation which does not form the image of defects. Scattered radiation generated inside and outside a material has a very large effect on ...

1998-02-01

63

Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine  

CERN Document Server

This book examines the applications of Monte Carlo (MC) calculations in therapeutic nuclear medicine, from basic principles to computer implementations of software packages and their applications in radiation dosimetry and treatment planning. It is written for nuclear medicine physicists and physicians as well as radiation oncologists, and can serve as a supplementary text for medical imaging, radiation dosimetry and nuclear engineering graduate courses in science, medical and engineering faculties. With chapters is written by recognised authorities in that particular field, the book covers the entire range of MC applications in therapeutic medical and health physics, from its use in imaging prior to therapy to dose distribution modelling targeted radiotherapy. The contributions discuss the fundamental concepts of radiation dosimetry, radiobiological aspects of ...

2003-01-01

64

Theoretical considerations for X-ray phase contrast mammography by Thomson source  

Energy Technology Data Exchange (ETDEWEB)

The advent, in the near future, of compact X-ray sources like Thomson Back-Scattering (TBS) will allow the clinical application of advanced X-ray imaging techniques, such as phase contrast, with higher sensitivity and lower impact in terms of dose delivery. In this work, we theoretically investigated the possibility of using such sources for phase contrast imaging of micro-calcifications included in a breast tissue. In our study we analyzed the phase and amplitude distribution of the TBS source and we showed that this source can be used for phase contrast imaging since the source coherence at the sample position is sufficiently high for achieving good contrast and micrometer spatial resolution. Indeed the spatial coherence of a TBS source is closer to that of a synchrotron radiation source, and much better than that of a laboratory source. Moreover, we showed the advantages of phase ...

2009-09-01

65

Reduction of fluoroscopic exposure for the air-contrast barium enema  

Energy Technology Data Exchange (ETDEWEB)

In a fluoroscopic imaging system, image quality and patient dose are both affected by the optical system linking the image intensifier with the video camera. The effect on patient exposure of increasing the optical iris aperture size over that required for other procedures performed on the same imaging system was investigated for the air-contrast barium enema examination. Using a large-area transmission ionisation chamber to monitor the Roentgen-area-product of entrance exposure, a decrease in fluoroscopic radiation of greater than 50% was clinically documented for a fluoroscopic system utilising kVp and mA variable automatic brightness control. For this iris change, the video image was of acceptable quality for positioning and monitoring the patient, and no deleterious effect was detected in the conduct of the air-contrast exam. The availability of a ...

1983-11-01

66

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

68

Epilogue - GES DISC - NASA  

Science.gov (United States)

Sep 9, 2009... a French Ariane rocket successfully launched a new Earth-observing satellite ... The payload is a pair of identical sensors known as "high-resolution ... the resulting image) are activated simultaneously by incoming radiation; ...

69

Efficiency of silicon and GaAs concentrator solar cells operated inside integrating cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

The theory for the general case of solar cells operating inside integrating cavity receivers is established. This is applied to the particular case of different configurations of silicon and GaAs cells. The results of the analysis show that a composite system of silicon and GaAs cells manufactured using relatively simple technology could reach an efficiency of 34%. The optimal configuration is that in which the GaAs cells are placed in the directly illuminated area of the receiver and the silicon cells are placed in the indirectly illuminated area of the receiver. (orig.).

1991-06-01

71

Optimisation of imaging technique used in direct digital radiography  

Energy Technology Data Exchange (ETDEWEB)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. ...

2006-09-15

72

Optimisation of imaging technique used in direct digital radiography  

International Nuclear Information System (INIS)

The purpose of the study was to optimise the technique employed for AP shoulder and lateral cervical spine examinations following an investigation into image quality, based on clinical assessment, and effective dose, calculated from patient entrance surface dose measurements. A study was therefore conducted in an attempt to determine whether the increased radiation dose to the patient following the introduction of an anti-scatter grid was justified by the level of improvement in image quality. The study, involving 100 patients, was able to demonstrate that the increase in radiation dose to the patient when using an anti-scatter grid for AP shoulder examinations is not justified by the improved image quality. A poor level of inter-rater reliability between the consultants scoring the lateral cervical spine images prevented a firm conclusion from being reached. ...

2006-09-01

73

Sample preparation for nanoanalytical electron microscopy using the FIB lift-out method and low energy ion milling  

International Nuclear Information System (INIS)

Thinning specimens to electron transparency for electron microscopy analysis can be done by conventional (2-4 kV) argon ion milling or focused ion beam (FIB) lift-out techniques. Both these methods tend to leave 'mottling' visible on thin specimen areas, and this is believed to be surface damage caused by ion implantation and amorphisation. A low energy (250-500 V) Argon ion polish has been shown to greatly improve specimen quality for crystalline silicon samples. Here we investigate the preparation of technologically important materials for nanoanalysis using conventional and lift-out methods followed by a low energy polish in a GentleMill"T"M low energy ion mill. We use a low energy, low angle (6-8 deg.) ion beam to remove the surface damage from previous processing steps. We assess this method for the preparation of technologically important materials, such as steel, silicon and GaAs. For these materials the ability to create specimens from specific sites, and ...

2006-02-22

74

0--30 keV low-energy focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga/sup +/ ion beams <0.3 ..mu..m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga/sup +/ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.

1988-05-01

75

0--30 keV low-energy focused ion beam system  

International Nuclear Information System (INIS)

Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga"+ ion beams <0.3 #mu#m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga"+ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.

76

Screen-film-combinations for radiography - present and future spectrum of application  

Energy Technology Data Exchange (ETDEWEB)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements.

1985-01-01

77

Screen-film-combinations for radiography - present and future spectrum of application  

International Nuclear Information System (INIS)

From the numbers of radiographs of the different examinations and the total amount of radiological diagnostics in the GDR their possible modification by new imaging techniques is discussed under the aspects of costs and radiation burden. Film-screen-systems are of special importance, because they also will be most frequently used image recording system in future. The importance of their various properties and parameters, methods of determining these parameters as well as future developments are analyzed from the standpoint of practical requirements. (author).

78

Nonlinear air-coupled emission: The signature to reveal and image microdamage in solid materials  

International Nuclear Information System (INIS)

It is shown that low-frequency elastic vibrations of near-surface planar defects cause high-frequency ultrasonic radiation in surrounding air. The frequency conversion mechanism is concerned with contact nonlinearity of the defect vibrations and provides efficient generation of air-coupled higher-order ultraharmonics, ultrasubharmonics, and combination frequencies. The nonlinear air-coupled ultrasonic emission is applied for location and high-resolution imaging of damage-induced defects in a variety of solid materials.

2007-12-17

79

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

80

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

81

Solar energy conversions: solar-electric thermophotovoltaic systems and solar-powered gas lasers  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with conversions of solar energy efficiently into electricity and into gas laser radiation. In the first section, a review study of the possibility of a solar-electric thermophotovoltaic (TPV) device has been done. In a proposed extension of the TPV concept, a Cassagranian optical system concentrates solar radiation to heat a blackbody cavity to 2400/sup 0/K. A double-layer solar cell, GaAs and Si, forming the cylindrical surface concentric to the blackbody cavity, receives the blackbody radiation and converts it into electricity efficiently. A cell conversion efficiency of 50% or more would be possible with the TPV system. The second section explores the concept of blackbody radiation pumping of gas laser media as a step toward utilization of solar energy as a laser pumping source. To demonstrate this concept, an experiment was performed in which various gas ...

1980-12-01

82

Gastrointestinal radiography using Fuji computed radiography (FCR)  

International Nuclear Information System (INIS)

Initial clinical experience in gastrointestinal radiography using Fuji Computed Radiography(FCR) system was reported. Image quality of conventional film/screen radiography and FCR system on upper GI series and barium enema was compared. Reflecting wide dynamic range of the system, improved image quality was confirmed, particularity in visibility of fine mucosal pattern(area gastricae), folds and overall contour. High sensor sensitivity of the system could reduce radiation dose requirement significantly. Diagnostically acceptable images were obtained with approximately 1/5 of routine dose for conventional radiography except in cases of lateral view of the rectum. (author).

1985-01-01

83

Methods and results of a representative analysis of the radiation exposure of the population by diagnostic radiology  

International Nuclear Information System (INIS)

From the frequency of diagnostic radiologic examinations and their radiation dose delivered to the population the risk of cancer induction and genetic damage is calculated on the basis of the risk factors given by the ICRP. Thus 0.38 % and 3 % of the total mortality for cancer and leukemia, resp., can be attributed to X-ray diagnostics. Chest examinations alone result in 0.07-0.7 damages per 100,000 persons depending on the imaging technique applied. (author).

1984-01-01

84

Computed radiography for major airway in pediatrics  

International Nuclear Information System (INIS)

This paper shows the efficacy of computed radiography for major airway in pediatrics. For this purpose, we examined 40 children (range 2 weeks to 14 years; mean 2.3 years) using Fuji Computed Radiography (FCR) and radiation dose using pediatric phantom under FCR and conventional film and screen system. In comparison study with FCR and conventional film and screen system, FCR images are superior to conventional system in all cases. Scorings were done for the quality of the image of the pharynx, the trachea, and both main bronchi. In phantom study to check radiation dose, radiation dose could be reduced 1/6 of the value using high speed film and screen and 1/15 of the value using conventional speed film and screen. FCR also showed clear airway images in all cases but technical failure to evaluate the clinical lesion. These results suggest that FCR is the adequate ...

1986-01-01

85

Development of high-efficiency GaAs solar cells on polycrystalline Ge substrates  

Energy Technology Data Exchange (ETDEWEB)

Progress in the development of high-efficiency GaAs solar cells on low-cost, large-area, large-grain, optical-grade polycrystalline Ge substrates is described in this paper. First, we present results on the growth of specular GaAs-AlGaAs layers, across the various crystalline orientations of a polycrystalline Ge substrate, by metallorganic chemical vapor deposition (MOCVD). Second, we present the preliminary optimization of minority-carrier properties of GaAs-AlGaAs structures on poly-Ge substrates towards the improvement of GaAs solar cells. We have demonstrated comparable minority-carrier lifetimes in GaAs double-hetero structures grown on optical-grade poly-Ge substrates and electronic-grade single-crystal Ge substrates. In addition, we describe device-structure optimization that have led us to achieve a open-circuit voltage of {approximately}1 Volt in a GaAs solar cell on poly-Ge and to improve our ...

1996-01-01

86

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. ...

2001-01-01

87

Normalized noise power spectrum of full field digital mammography detector system  

International Nuclear Information System (INIS)

Full text: A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through de trending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality. (author)

88

Normalized Noise Power Spectrum of Full Field Digital Mammography System  

International Nuclear Information System (INIS)

A method to measure noise power spectrum of a full field digital mammography system is presented. The effect of X-ray radiation dose, size and configuration of region of interest on normalized noise power spectrum (NNPS) was investigated. Flat field images were acquired using RQA-M2 beam quality technique (Mo/Mo anode-filter, 28 kV, 2 mm Al) with different clinical radiation doses. The images were cropped at about 4 cm from the edge of the breast wall and then divided into different size of non-overlapping or overlapping segments. NNPS was determined through detrending, 2-D fast Fourier transformation and normalization. Our measurement shows that high radiation dose gave lower NNPS at a specific beam quality.

2010-01-05

89

Projection techniques in diagnostic radiography discussed with regard to required dose  

International Nuclear Information System (INIS)

The paper presents information in the form of data, tables and diagrams compiled to a broad but very up-to-date survey of required radiation for the various most frequently performed X-ray examinations of patients. The required dose is discussed from the point of view of radiation protection, defining the inevitably administered dose to the skin, the frequency of examinations, and the diagnostic image quality as the main three factors to be observed, as these determine the radiation dose to the patient and to the personnel. The somatic risks of radiography examinations are a point of main interest. (DG).

1990-09-01

90

Conformal radiation therapy: technical requirements and clinical applications  

International Nuclear Information System (INIS)

Conformal radiation therapy represents a considerable and attractive challenge in oncology. Its aim is mainly to improve local control by increasing the dose with an acceptable rate of complications. This work overviews the world literature on this subject. The technical and theoretical requirements are highlighted. These requirements include a precise definition of the target volume by digital imaging (essentially CT scan), but also clear view of the target volume and the organs at risk, a specific collimation of the beam, 3-D dose calculations, optimization procedures, and a rigid immobilization of the patient with verification of his position. Moreover, the clinical applications of conformal radiation therapy are reviewed and discussed. (authors). 80 refs., 1 tab.

1995-01-01

91

Inverse Bloch-oscillator: Strong Thz-photocurrent resonances at the Bloch frequency  

Energy Technology Data Exchange (ETDEWEB)

We have observed resonant changes in the current-voltage characteristics of miniband semiconductor superlattices when the Bloch frequency is resonant with a terahertz field and its harmonics: the inverse Bloch oscillator effect. The resonant feature consists of a peak in the current which grows with increasing laser intensity accompanied by a decrease of the current at the low bias side. The peak position moves linearly with the laser frequency. When the intensity is increased further the first peak starts to decrease and a second peak at about twice the voltage of the first peak is observed due to a two photon resonance. At the highest intensities we observe up to a four photon resonance. A superlattice is expected to show negative differential conductance due to the strong nonparabolicity of the miniband. In this situation the carriers should undergo Bloch oscillations with a frequency {omega}{sub B} = eEd/h. Transient Bloch oscillations of photo excited carriers have been observed ...

1995-12-31

92

Quantitative analysis of X-Ray Microtomography images of metal powders in the course of sintering  

Energy Technology Data Exchange (ETDEWEB)

In situ X-Ray microtomography offers new opportunities for analysing sintering mechanisms since it allows 3D observation of the microstructural evolution of the powder all along a sintering cycle. With synchrotron radiation at ESRF, a 3D image with a resolution of 2 {mu}m can be obtained in about one minute. In addition to the visual examination of the images, relevant microstructural parameters can be measured through quantitative image analysis using recently developed tools. In this paper the results obtained with two materials, loose copper powder and compacted steel powder, are resumed. For copper powder, the dispersion of local parameters such as particle co-ordination number and porosity is investigated. Concerning steel compacts, data about pore morphology evolution and on local strains provides clues for understanding the anisotropic shrinkage of such compacts. (authors)

2005-07-01

93

Polynomial curve fitting method for refraction-angle extraction in diffraction enhanced imaging  

International Nuclear Information System (INIS)

X-ray diffraction enhanced imaging (DEI) is applied to inspect internal structures of weakly absorbing low-Z sample. How to extract phase information from raw images measured in different positions of rocking curve is the key problem of DEI. In this paper, we present an effective extraction method called polynomial curve fitting method, in order to extract accurate information angular in a fast speed. It is com- pared with the existing methods such as multiple-images statistical method and Gaussian curve fitting method. The experiments results on a plastic cylinder and a black ant at the Beijing Synchrotron Radiation Facility prove that the polynomial curve fitting method can obtain most approximate refraction-angle values and its computation speed is 10 times faster than the Gaussian curve fitting method. (authors)

2009-11-01

94

Ion beam induced charge imaging of epitaxial GaN detectors  

Energy Technology Data Exchange (ETDEWEB)

We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.

2004-09-21

95

Diffusion tensor MR imaging in pediatric patients with periventricular leukomalacia  

International Nuclear Information System (INIS)

Objective: To compare pediatric patients with periventricular leukomalacia (PVL) with normal children by using diffusion tensor MR imaging. Methods: Diffusion tensor images were obtained in 15 pediatric patients with PVL and 15 age-matched normal children. Regions of interest were drawn to measure the fractional anisotropy (FA) in bilateral posterior limb of internal capsule, bilateral optic radiation, genu of corpus callosum, and splenium of corpus callosum. The values of PVL patients and normal children were compared using non-dependent samples T-test. Results: The FA values of regions of interest prescribed were significantly lower in PVL patients than in normal children (P<0.01). Conclusion: Diffusion tensor imaging may reveal retard of myelination of fiber tracts in PVL patients. It can be a potential tool in evaluating the brain development of children. (authors)

2005-03-01

96

Angiography of the head using Fuji computed radiography (FCR) system  

International Nuclear Information System (INIS)

Forty-seven subtraction images of FCR were compared with subtraction images of conventional angiography of the head. Quality of the FCR images were equal or superior to that of conventional angiography. Antero-posterior projection of external carotid arteriography by FCR was most useful because of its wide dynamic range. As contrast resolution of FCR is superior to that of conventional angiography, only half diluted contrast media was needed. As for spacial resolution, FCR is slightly inferior to conventional angiography. However, most vessels which are clinically important were adequately demonstrated. A weak point of FCR which should be improved is relatively long time to process the images after radiation exposure. (author).

1985-01-01

97

Radiation exposure to anesthesiologist and nurse in the orthopedic room  

International Nuclear Information System (INIS)

We report the radiation exposure dose received by the anesthesiologist and nurse in the orthopaedic operating room, when a fluoroscopic image intensifier is in use. This study was done in 12 femoral neck fracture operations performed from January to May 1995. Radiation was monitored with the MYDOSE MINIX PDM 107 made by Aloka Co. which were attached in front and behind the nurse's lead apron, in front of the lead apron of the anesthesiologist. The average imaging time was 9.78 min. The average radiation dose in front of the anesthesiologist is lead apron was 2.08#mu#SV, and in front and behind the nurse's lead apron were 5.67#mu#SV, 0.08#mu#SV respectively. This study and review of the literature indicate that the operating room anesthesiologist and nurse receive a lower exposure than the orthopaedist. We can disregard the problem of radiation exposure to the ...

98

Exploring the mechanism of radiation-enhanced hepatocellular carcinoma cell invasion by swept source optical coherence tomography  

Science.gov (United States)

Ionizing radiation is a standard treatment for various human solid tumors. However, several clinical studies showed that a significant proportion of patients undergoing radiotherapy for hepatocellular carcinoma (HCC) develop intrahepatic and extrahepatic metastasis. Understanding of radiation-induced cancer cell invasiveness and behavior is essential and of great important for developing suitable treatment strategies to contain cancer spread. Therefore, in this study we evaluated the effectiveness of using swept source optical coherence tomography (SS-OCT) to monitor the enhancement of HCC cell invasiveness by radiation. SS-OCT images were acquired and recorded to obtain three-dimensional data sets per four hours in 48 hours after irradiating HepG2 cells with 7.5 Gy. The cell migration behavior in three-dimensional tissue models was quantified from images of ...

2011-02-01

99

Verification of electron beam therapy with storage phosphor images: Precision of field placement  

Energy Technology Data Exchange (ETDEWEB)

Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in ...

1990-04-01

100

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

Energy Technology Data Exchange (ETDEWEB)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, ...

2000-07-01

101

Need for New Optimisation Strategies in CR and Direct Digital Radiography  

International Nuclear Information System (INIS)

Digital imaging techniques such as Digital Image Intensifier Radiography and Digital Storage Phosphor (Selenium) Radiography are replacing conventional film-screen radiography more and more. The aim of this development is the extension of diagnostic capabilities and the reduction of side effects such as radiation dose. Conventional film-screen radiography and digital radiography are very different ways of imaging. For digital radiography specific post-processing is the link between imaging conditions and film documentation. Optimisation of the images includes new possibilities of post-processing and a broad range for variation of the dose. Especially in fluoroscopy, dose can be reduced significantly by new technical features like pulsed fluoroscopy. For digital radiography the European guidelines on quality criteria have to be applied to projection radiography, ...

1999-06-13

102

Hard x-ray phase imaging using simple propagation of a coherent synchrotron radiation beam  

International Nuclear Information System (INIS)

Particularly high coherence of the x-ray beam is associated, on the ID19 beamline at ESRF, with the small angular size of the source as seen from a point of the sample (0.1-1 #mu#rad). This feature makes the imaging of phase objects extremely simple, by using a 'propagation' technique. The physical principle involved is Fresnel diffraction. Phase imaging is being simultaneously developed as a technique and used as a tool to investigate light natural or artificial materials introducing phase variations across the transmitted x-ray beam. They include polymers, wood, crystals, alloys, composites or ceramics, exhibiting inclusions, holes, cracks, ... . 'Tomographic' three-dimensional reconstruction can be performed with a filtered back-projection algorithm either on the images processed as in attenuation tomography, or on the phase maps retrieved from the images with a reconstruction procedure similar to ...

1999-05-21

103

Reduced resolution polarimetric imagery characterization of the 1990 Galveston Bay oil spill  

Energy Technology Data Exchange (ETDEWEB)

Low resolution visual polarimetric photographic imagery of the Galveston Bay oil spill from a tanker accident on July 28, 1990 was obtained and analyzed. The low resolution imagery (30 to 100 meters) was obtained concurrently with high resolution (1 meter), and is representative of what would be seen by a polarimetric satellite. Orthogonal red-green-blue (RGB) polarimetric images obtained with color photography were digitized by KODALUX on to a CD ROM. These polarimetric images were then used to calculate the percent polarization. The positive and negative percent polarized radiation scattered by each of the sea surface waves is seen individually in high resolution imagery. (Percent polarization is defined as positive when the dominant radiation is perpendicular to the plane of incidence and negative when it is parallel). The analysis of low resolution polarimetry is approached in a different manner ...

1997-06-01

104

Sensitization and radiation hardening of the photostimulable X-ray storage phosphor CsBr:Eu2+  

British Library Electronic Table of Contents (United Kingdom)

The X-ray storage phosphor CsBr:Eu2+ in form of needle image plates is believed to be a promising alternative to the granular BaFBr:Eu2+ with regard to PSL yield and spatial resolution. Unfortunately, CsBr:Eu2+ exhibits poor radiation hardness, which is caused by a migration of europium ions initiated by naturally existing defect centers like (Eu2+-VCs)-centers and X-ray generated MEu-centers. It will be shown that the formation of (Eu2+-O2?)-dipoles at the expense of (Eu2+-VCs)-dipoles, incorporated by thermal annealing in O2-containing and humid atmosphere, does not improve the radiation stability. There is, however, a strong improvement in the radiation hardness by codoping of CsBr:Eu2+ with lithium ions, which is accompanied by a complete suppression of the previously observed MEu-cent...

2009-01-01

105

Formulation and practice of standards for radiation protection of #gamma#-ray industrial computed tomography  

International Nuclear Information System (INIS)

There are many differences between industrial CT and industrial radiography, such as imaging principle, inspection time, radiation dose and the requirements for operators etc. The national standards for radiation protection of industrial detection are not applicable to the requirements of protection and safety for #gamma#-ray industrial CT to some extent now. In order to standardize the production and use for #gamma#-ray industrial CT, protect the safety of operators and the public, and to promote the popularization and application of #gamma#-ray industrial CT, it is significant to establish the national standards for radiation protection of #gamma#-ray industrial CT as soon as possible. The purpose of this paper is to introduce the contents of this standard, and specify some important terms. Then there is a brief discussion on the existing problems during establishing such standards. At last, the paper ...

2009-03-01

106

The Structural and Optical Properties of GaAs1-xPx /GaAs  

International Nuclear Information System (INIS)

GaAs1-xPx p-n junction structures were grown on the epi-ready n-type GaAs(100) substrate by solid source MBE system for different phosphor compositions. To obtain the lattice-match sample structure was applied graded growth procedure. The structural and optical properties of the sample structures with different P concentration were investigated by using X-ray diffraction (XRD), spectroscopic ellipsometry (SE). In addition, The range of lattice parameters in the graded epilayer and phosphorous composition were determined from the HRXRD rocking curve simulation. We analyse dielectric function spectra of disordered GaAs1-xPx junction structures measured using spectroscopic ellipsometry at room temperature in the 0.6-4.7 eV photon energy region. The critical energy points such as band gap energy and spin-orbit-split energy of these structures were determined using SE data. It is detected that E0, E1 ,E2 energies of the ...

2008-08-25

107

Surface-plasma interactions in GaAs subjected to capacitively coupled RF plasmas  

CERN Document Server

Surface compositional changes in GaAs due to RF plasmas of different gases have been investigated by XPS and etch rates were measured using AFM. Angular Resolved XPS (ARXPS) was also employed for depth analysis of the composition of the surface layers. An important role in this study was determination of oxide thickness using XPS data. The study of surface - plasma interaction was undertaken by correlating results of surface analysis with plasma diagnosis. Different experiments were designed to accurately measure the BEs associated with the Ga 3d, Ga 2p sub 3 sub / sub 2 and LMM peaks using XPS analysis and propose identification in terms of the oxides of GaAs. Along with GaAs wafers, some reference compounds such as metallic Ga and Ga sub 2 O sub 3 powder were used. A separate study aiming the identification of the GaAs surface oxides formed on the GaAs surface during and after ...

2002-01-01

108

The dust distribution in edge-on galaxies. Radiative transfer fits of V and K'-band images  

CERN Document Server

Aims: I have analyzed a sample of seven nearby edge-on galaxies observed in the V and K'-band, in order to infer the properties of the dust distribution. Methods: A radiative transfer model, including scattering, have been used to decompose each image into a stellar disk, a bulge, and a dust disk. The parameters describing the distributions have been obtained through standard X^2 minimization techniques. Results: The dust disks fitted to the V-band images are consistent with previous work in literature: the radial scalelength of dust is larger than that for stars (h_d/h_s ~ 1.5); the dust disk has a smaller vertical scalelength than the stellar (z_d/z_s ~ 1/3); the dust disk is almost transparent when seen face-on (central, face-on, optical depth tau_0 =0.5-1.5). Faster radiative transfer models which neglect scattering can produce equivalent fits, with changes in the derived parameters within the ...

2007-01-01

109

Polycrystalline MBE-grown GaAs for solar cells  

Energy Technology Data Exchange (ETDEWEB)

This paper will discuss initial studies of thin-film GaAs grown by molecular-beam epitaxy for use in developing a thin-film GaAs solar cell. Photocurrent and photoluminescence intensity are related to the material morphology as a function of growth conditions. Growth temperature and V/III ratio have a dramatic effect on the photocurrent. However, it seems likely that even after optimizing such growth parameters, it will be necessary to provide substrates that can provide templates to enhance grain size from the start of thin-film growth. {copyright} {ital 1997 American Institute of Physics.}

1997-02-01

110

GaInP[sub 2]/GaAs tandem cells: Problems and solutions  

Energy Technology Data Exchange (ETDEWEB)

The various factors that affect the open-circuit voltage ([ital V][sub oc]) of a two-terminal GaInP[sub 2]/GaAs tandem cell are examined. These include a) an anomalous problem associated with the GaAs bottom cell and b) back surface passivation of the thin GaInP[sub 2] top cell. Solutions to these problems are presented and yield tandem [ital V][sub oc]s close to the practical theoretical limits.

1992-12-01

111

Formation and coarsening of Ga droplets on focused-ion-beam irradiated GaAs surfaces  

International Nuclear Information System (INIS)

We have investigated the formation and coarsening of Ga droplets on focused-ion-beam (FIB) irradiated GaAs surfaces. To separately examine formation and coarsening, Ga droplets were fabricated by Ga"+ FIB irradiation of GaAs substrates with and without pre-patterned holes. We determined the droplet growth rate and size distribution as a function of FIB energy following irradiation. The data suggest a droplet formation mechanism that involves Ga precipitation from a Ga-rich layer, followed by droplet coarsening via a combination of diffusion and Ostwald ripening or coalescence via droplet migration (dynamic coalescence).

2009-10-12

112

Design of a neutron radiography collimator system in a through beam port at the TRIGA reactor  

Energy Technology Data Exchange (ETDEWEB)

A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.

1996-12-31

113

MOCVD growth of GaAs solar cells on silicon substrates  

Energy Technology Data Exchange (ETDEWEB)

This paper reports advances in the development of solar cells made from GaAs-on-Si structures prepared by metalorganic chemical vapor deposition (MOCVD). The use of concentrator cells, operating at [similar to]200 suns, has led to the efficiency achievements of 21.3% (AM1.5D) for a GaAs-on-Si solar cell, and 27.6 (AM1.5D) for a homoepitaxial GaAs cell. The development of epitaxial multilayer dielectric mirrors (Bragg reflectors), as back-surface reflectors in thin-film GaAs cells, on both Si and GaAs substrates, is shown to lead to modest efficiency increases, over that of conventional designs.

1992-12-01

114

Antiferromagnetic ordering of defects in GaAs  

Energy Technology Data Exchange (ETDEWEB)

The magnetic susceptibility of GaAs samples containing a large concentration of native defects was investigated by dc magnetization measurements. Thin GaAs films grown by molecular-beam epitaxy at very low temperatures and bulk GaAs:S samples irradiated with fast neutrons have been studied. For all samples, the susceptibility follows a Curie-Weiss law, indicating the presence of localized magnetic moments. These moments are attributed to unpaired spins located at the native defects. Negative Curie-Weiss temperatures found for both neutron-irradiated and low-temperature-grown GaAs is a clear manifestation of an antiferromagnetic interaction between the moments. The presence of a highly inhomogeneous distribution of native defects has to be assumed to account for the observed antiferromagnetic ordering.

1992-10-15

116

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high aluminium-filtering is a further ...

1981-01-01

117

Radio nuclear aggression. Psychological impact and management; L'agression radio-nucleaire. Impact psychologique et prise en charge  

Energy Technology Data Exchange (ETDEWEB)

Long before possible organic effects, exposure to ionizing radiations can provoke anxiety. In front of invisibility, the imagination quickly ignites. The terrorists have perfectly understood it. They are ready to use ionizing radiations as a weapon to remind traumatic images deeply rooted in people's memory. These images induce anxiety with all the clinical expressions connected to it. These symptoms require to be treated because of a possible anarchic development. For that purpose, plans have been elaborated to coordinate the different professional's actions. The coherence of medical management and communication aims to allow the most implicated people to find the way to face the events. When it is not possible, medico-psychological cells permit a specialized care. (author)

2006-08-15

118

Ewing's sarcoma recurrence vs radiation necrosis in dynamic contrast-enhanced MR imaging: a case report  

International Nuclear Information System (INIS)

Purpose. We report a case of Ewing's sarcoma in the right distal femur in a 6-year-old male to demonstrate how dynamic contrast-enhanced magnetic resonance imaging (DEMRI) findings predicted histopathology. Materials and methods. DEMRI was performed at presentation and during and after completion of chemotherapy and radiation therapy. Histopathologic studies were done at presentation, at 77 weeks (20 weeks after a pathological fracture), and from the en bloc resection at 104 weeks. Results. DEMRI predicted the early tumor response, absence of tumor recurrence, presence of necrosis and lack of fracture healing, confirmed by histopathology. Conclusion. DEMRI is a clinically useful tool in managing Ewing's sarcoma. (orig.)

1999-04-01

119

Recent developments and applications for the University of Texas thermal neutron imaging facility  

Energy Technology Data Exchange (ETDEWEB)

The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system resolution have hot been determined. The TNIF is currently being ...

2001-07-01

120

Infrared radiation features of coal and rocks under loading  

Energy Technology Data Exchange (ETDEWEB)

Samples of fat coal-E, its roof sandstone-A and blind coal-W from two coal mines in Hebei Province of China were brought to the laboratory to study the features of infrared thermal images and radiation temperature in the course of uni-axial load and uni-axial cycle load. To check the results of infrared remote sensing detection, two other methods, acoustic emission detection and electrical resistance detection were also used. The AGA-782 thermalvision detected change of the temperature field of the samples` surfaces. The study showed that: (1) coal rocks and sandstone in the course of loading have three types of infrared thermal image features and three types of infrared radiation temperature features; (2) infrared detection is comparable with acoustic emission detection and electrical resistance detection. Generally, the infrared forewarning of coal rocks` failure comes later than that of acoustic and ...

1998-10-01

121

Real-time neutron monitoring method using an imaging plate  

Energy Technology Data Exchange (ETDEWEB)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-07-01

122

Real-time neutron monitoring method using an imaging plate  

International Nuclear Information System (INIS)

A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)

1999-04-19

123

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

Energy Technology Data Exchange (ETDEWEB)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-12-01

124

Evaluation of digital radiography (Fuji computed radiography) for portable chest radiographs in ICU  

International Nuclear Information System (INIS)

To evaluate the usefulness of portable chest radiographs by Fuji computed radiography (FCR) in ICU, FCR radiographs of 56 patients who were admitted to General Intensive Care Unit of Keio University Hospital were compared with the conventional portable images. Because FCR could show two differently processed images in one film and allowed a wide range of image reproduction, visualization of the trachea, bone soft tissues and catheters by FCR was easier than that by the conventional radiography. Repeated radiographs by FCR had similar optical densities and limited exposure errors. Furthermore, radiation was reduced than that of the conventional radiography. In conclusion, FCR is thought to be a useful technique for portable chest radiography in ICU patients. (author).

1992-01-01

125

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

126

MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry  

Energy Technology Data Exchange (ETDEWEB)

Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. A robust tool for the evaluation of the nonuniformity in MRI has been developed, the Deviation Image method. Unlike previously presented methods, the Deviation Image method includes all nonuniformity variations across a phantom surface and is insensitive to stochastic noise. Methods for the estimation of stochastic noise were analyzed in terms of sensitivity to nonuniformities. A method that averages the stochastic noise level over five regions over the phantom surface, and a method that assesses the stochastic noise level from the ...

2001-03-01

127

Development of a computerized portal verification scheme for pelvic treatment fields  

International Nuclear Information System (INIS)

Purpose/Objective: At present, treatment verification between portal and reference images is performed based on manually-identified features by radiation oncologist, which is both time-consuming and potentially error-prone. There is a demand for the computerized verification procedure in clinical application. The purpose of this study is to develop a computerized portal verification scheme for pelvic treatment fields. Materials/Methods: The automated verification system involves image acquisition, image feature extraction, feature matching between reference and portal images and quantitative evaluation of patient setup. Electronic portal images with a matrix size of 256 x 256 and 12 bit gray levels were acquired using a liquid matrix electronic portal imaging device. Simulation images were acquired by digitizing ...

1996-09-01

128

Ferromagnetism in Mn-doped GaAs layers: Effects of laser annealing  

Energy Technology Data Exchange (ETDEWEB)

The properties of Mn-doped GaAs layers grown by laser deposition were investigated with measurements of Hall effect and magneto-optical Kerr effect (MOKE). The electrical and magnetic parameters of the layers were defined by growth temperature and quantity of sputtered Mn. It was shown that room-temperature ferromagnetism is revealed by MOKE and, after ruby laser 25 ns pulse annealing, by Hall effect measurements.

2006-05-15

129

Plane electrode device for multiwire detector for ionizing radiations  

International Nuclear Information System (INIS)

A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.

1986-07-01

130

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all ...

2003-12-01

131

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings was applied. The data of all groups were ...

2003-12-01

132

P and e identification capabilities CAPRICE  

Energy Technology Data Exchange (ETDEWEB)

The cosmic antiparticle ring imaging Cherenkov experiment (CAPRICE) flew on a stratospheric balloon 8-9 August 1994 over northern Canada and collected data for more than 21 hours with less than 5 g/cm{sup 2} of residual atmosphere. The instrument includes a solid radiator RICH detector and an electromagnetic calorimeter for particle identification in the magnetic spectrometer. Preliminary antiproton and positron identification capabilities are presented.

1995-09-01

133

In vivo99mTc-HYNIC-annexin V imaging of early tumor apoptosis in mice after single dose irradiation  

UK PubMed Central (United Kingdom)

BackgroundApoptosis is a major mode of hematological tumor death after radiation. Early detection of apoptosis may be beneficial for cancer adaptive treatment. 99mTc-HYNIC-annexinV...Full Text Available

134

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

135

Study of the effects of interactions quantum interference and disorder in GaAs and of GaAs jointed to a superconductor; Etude des effets d`interference quantique et de desordre dans GaAs avec interactions et GaAs connecte a un supraconducteur  

Energy Technology Data Exchange (ETDEWEB)

The aim of this thesis is to study the coherent transport in semiconducting-superconducting junctions. The SnPb-GaAs system has been studied. It has been shown that the behaviour of this junction is controlled by the disordered area induced by the annealing of the connection near the interface. For a few resistant junction, a conductance anomaly under the gap has been observed and has been explained by a mesoscopic effect in the limit of the very high disorders. The conductance of more resistant junctions has only been bound to the properties of the very disordered area of the semiconductor. The part of the electron-electron interactions on the phase coherence length and on the conductance has been studied. The evolving of the correction of the conductance due to interactions in magnetic field has been followed. The effect of the spin degeneration suppression in CdTe and the GaAs sign inversion in Shubnikov de Haas oscillations rate has been observed. At last has ...

1997-11-07

136

GaAs concentrator cell production cost analysis  

Energy Technology Data Exchange (ETDEWEB)

The utilization of GaAs in photovoltaic (PV) applications has been hindered by the cost of substrates and processing. This paper examines the cost effectiveness of GaAs cells for use in concentrator modules when produced at the 10 to 50 MW level per year. Information on costs associated with substrates, epitaxial processing, and subsequent device fabrication will be compared to allowable costs as projected by the US Department of Energy (DOE). The high cot of GaAs solar cells can be mitigated by use of low-cost substrates or high-concentration systems. The costs then can be accommodated when the production level is sufficiently high to take advantage of economies of scale in device processing and substrate price benefits when procured at high volumes. We have found that development of processing equipment, both for the epitaxial growth and device processing, is the key to obtaining production costs consistent with DOE ...

1992-12-01

137

Numerical Models of Sgr A*  

CERN Document Server

We review results from general relativistic axisymmetric magnetohydrodynamic simulations of accretion in Sgr A*. We use general relativistic radiative transfer methods and to produce a broad band (from millimeter to gamma-rays) spectrum. Using a ray tracing scheme we also model images of Sgr A* and compare the size of image to the VLBI observations at 230 GHz. We perform a parameter survey and study radiative properties of the flow models for various black hole spins, ion to electron temperature ratios, and inclinations. We scale our models to reconstruct the flux and the spectral slope around 230 GHz. The combination of Monte Carlo spectral energy distribution calculations and 230 GHz image modeling constrains the parameter space of the numerical models. Our models suggest rather high black hole spin ($a_*\\approx 0.9$), electron temperatures close to the ion temperature ($T_i/T_e ...

2010-01-01

138

Experience in using Fuji computed radiography (FCR), 1  

Energy Technology Data Exchange (ETDEWEB)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR ...

1984-12-01

139

Experience in using Fuji computed radiography (FCR), 1  

International Nuclear Information System (INIS)

New experiment of radiography in using Fuji Intelligent Diagnostic X-ray System was first reported in XV International Congress of Radiology, 1981. By utilizing this system instead of traditional screen/film system, high density imaging plate in conjunction with computed image processor was developed, this is FCR. However, as the numerous problems in regard to the basic side of FCR system are found, it is expected that these are solved by investigators at their earliest opportunities. The purpose of this study is to reduce the radiation doses of the patients at radiography of the chest by using FCR system installed in our Department of Radiology in July, 1984. Experimentally we measured the radiation doses of the patient having the each breast of 18, 20, 22 and 24cm in thickness at radiography of the chest by using VICTOREEN MODEL 666 survey meter. The results obtained were as follows: 1) By using FCR ...

1984-01-01

140

Demonstration of a wide-band compact free electron laser to the THZ imaging of bio samples  

International Nuclear Information System (INIS)

We have developed a compact terahertz (THz) free electron laser (FEL). The FEL operates in the wavelength range of 100-1200 #mu#m, which corresponds to 0.3-3 THz. THz radiation from the FEL shows much higher power of 100 W compared to the power level, <100 mW, of the table-top sources by conventional lasers. The THz FEL beam shows good performance in pulse-energy stability, polarization, spectrum and spatial distribution. The main application of the FEL is THz imaging for bio-medical researches. We demonstrated the THz imaging of bugs for living condition at 3 THz. The bugs were died just before experiments, so they were not dried. We could get transmitted information through the samples by using the THz FEL beam. In this paper, we will estimate and discuss the required power level of the THz source for the practical application of the imaging.

2007-05-21

142

Focused ion beam damage to MOS integrated circuits  

Energy Technology Data Exchange (ETDEWEB)

Commercial focused ion beam (FIB) systems are commonly used to image integrated circuits (ICS) after device processing, especially in failure analysis applications. FIB systems are also often employed to repair faults in metal lines for otherwise functioning ICS, and are being evaluated for applications in film deposition and nanofabrication. A problem that is often seen in FIB imaging and repair is that ICS can be damaged during the exposure process. This can result in degraded response or out-right circuit failure. Because FIB processes typically require the surface of an IC to be exposed to an intense beam of 30--50 keV Ga{sup +} ions, both charging and secondary radiation damage are potential concerns. In previous studies, both types of effects have been suggested as possible causes of device degradation, depending on the type of device examined and/or the bias conditions. Understanding the causes of this damage is ...

2000-05-10

143

Optimization of doubly Q-switched lasers with both an acousto-optic modulator and a GaAs saturable absorber  

Science.gov (United States)

A doubly Q-switched laser with both an acousto-optic (AO) modulator and a GaAs saturable absorber can obtain a more symmetric and shorter pulse with high pulse peak power, which has been experimentally proved. The key parameters of an optimally coupled doubly Q-switched laser with both an AO modulator and a GaAs saturable absorber are determined, and a group of general curves are generated for what we believe is the first time, when the single-photon absorption (SPA) and two-photon absorption (TPA) processes of GaAs are combined, and the Gaussian spatial distributions of the intracavity photon density and the initial population-inversion density as well as the influence of the AO Q-switch are considered. These key parameters include the optimal normalized coupling parameter, the optimal normalized GaAs saturable absorber parameters, and the normalized parameters of the AO Q-switch, which can maximize ...

2007-08-20

144

A High-Frequency Secondary Event During the 2004 M6.0 Parkfield Earthquake  

Science.gov (United States)

We present an image of the rupture propagation of the 2004 M6.0 Parkfield earthquake using records from a dense network of local strong motion stations. We back-propagate high-frequency waveforms in 3D with a method, similar to reverse time migration, to obtain an estimate of the distribution of radiated high-frequency seismic energy in space and time. The image is forced to be coherent at the known hypocenter location and the quake origin time by applying small static time shifts obtained using waveform cross-correlation. We observe that the Parkfield earthquake radiated a distinct secondary high-frequency phase, which is located about 12.5~km northwest of the hypocenter with an onset of seismic radiation about 5~s after the rupture initiation. The time history of the back-projection suggests a rupture velocity of 2.5~km/s between hypocenter and subevent. The back-projection ...

2007-12-01

145

Adhesion studies of Au films on GaAs using ion-assisted deposition techniques  

International Nuclear Information System (INIS)

This paper reports on a series of experiments performed to examine the ability of ion beam assisted thermal deposition to produce good adhesion of Au metallization on GaAs left-angle 100 right-angle substrates. A study of the influence of Ar ion-assisted thermal deposition of the Au films as well as in situ pre-sputtering of the GaAs surface with low-energy Ar ions prior to thermal deposition, shows that strong adhesion can be achieved without resorting to chemical cleaning. The substrate temperature and the relative flux of Ar ions to incident Au atoms were varied in order to correlate these parameters with film adhesion. The interfaces of films processed under these various conditions were examined by XTEM, RBS and XPS. Orientation texture was studied by x-ray diffraction (XRD).

146

5 GHz GaAs monolithic astable multivibrator type voltage controlled oscillator  

Science.gov (United States)

A 5 GHz GaAs monolithic astable multivibrator-type voltage-controlled oscillator has been developed. The monolithic oscillator uses 2 micron long self-aligned TiW-silicide gate MESFETs as well as GaAs Schottky diodes for capacitance. Good agreement between the experiment and calculations for oscillation frequency characteristics versus control voltage is obtained by assuming donor density in the FET active layer to be a Gaussian distribution. This oscillator is useful for monolithic front ends and phase-locked oscillators used in microwave signal processing. X-band oscillation frequency can be obtained with 1 micron long gate FET and low loss resonance inductors.

1984-03-01

147

PET/MRI hybrid imaging: devices and initial results  

British Library Electronic Table of Contents (United Kingdom)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest...

2008-01-01

148

Evapotranspiration estimation using the Landsat-5 Thematic Mapper image over the Gyungan watershed in Korea  

British Library Electronic Table of Contents (United Kingdom)

Even if there have been efforts to validate remote-sensing-based energy balance models, which provide evapotranspiration (ET) maps over a large spatial scale, few studies have been conducted to validate their performance in Korea. In this study, surface energy balance fluxes including ET were estimated and inter-compared with two different models using the Landsat-5 Thematic Mapper (TM) image over a watershed scale in Korea. While there were larger spatial discrepancies for net radiation, soil heat and sensible heat fluxes on a pixel-by-pixel basis between the two models, relatively smaller spatial discrepancies for the latent heat flux and daily ET were detected. The spatial discrepancies for the daily ET were larger in low topography and dense vegetation ranges. Despite the different par...

2011-01-01

149

Biological effects and physical safety aspects of NMR imaging and in vivo spectroscopy  

Energy Technology Data Exchange (ETDEWEB)

An assessment is made of the biological effects and physical hazards of static and time-varying fields associated with the NMR devices that are being used for clinical imaging and in vivo spectroscopy. A summary is given of the current state of knowledge concerning the mechanisms of interaction and the bioeffects of these fields. Additional topics that are discussed include: (1) physical effects on pacemakers and metallic implants such as aneurysm clips, (2) human health studies related to the effects of exposure to nonionizing electromagnetic radiation, and (3) extant guidelines for limiting exposure of patients and medical personnel to the fields produced by NMR devices. On the basis of information available at the present time, it is concluded that the fields associated with the current generation of NMR devices do not pose a significant health risk in themselves. However, rigorous guidelines must be followed to avoid the physical ...

1985-08-01

150

Self-assessment of current knowledge in nuclear medicine (second edition)  

Energy Technology Data Exchange (ETDEWEB)

In this updated second edition, the order of contents of the textbook has been reorganized. It has been divided into main parts: Basic Science and Clinical Nuclear Medicine. Basic Science, Part I, encompasses basic physics, radiation protection, interaction of radiation with matter and radiation detection, imaging, nuclear pharmacy, and radiation biology. Part II, Clinical Nuclear Medicine, covers the central nervous system, bone, gastroenterology (liver/spleen), cardiovascular system, pulmonary system, genitourinary system, thyroid and endocrine systems, gallium studies, radioassay, hematology, and therapy. The total number of pages of the current edition is increased to 250 from the 213 of the first edition but there are fewer questions because those in the basic science area have been carefully selected to 60 of the original 98 questions. Compared with the previous edition, there ...

1981-01-01

151

Atlas of nuclear medicine imaging  

Energy Technology Data Exchange (ETDEWEB)

An exhaustive compendium of normal and abnormal imaging is presented. The following systems and procedures are illustrated by over 2800 captioned illustrations: liver, spleen, and hepatobiliary imaging; perfusion and ventilation lung imaging; thyroid imaging; salivary gland imaging; bone imaging; brain imaging; radionuclide cisternography; blood flow studies; gallium imaging; nuclear cardiology; and renal imaging. Not included in the atlas are adrenal imaging procedures and emission computed tomography. (ERB)

1981-01-01

152

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

153

Dynamically focussed array  

Energy Technology Data Exchange (ETDEWEB)

An array of sonic transducers, useful for medical ultrasonic imaging, has individual sections thereof separately coupled for forming separate beams of sonic energy which converge, respectively, to separate foci along a common axis of the beams. The ratio of the diameter of the radiating aperture of the array relative to a wavelength of the sonic energy is chosen to provide a moderate degree of focusing so that the depth of field at one focus blends with the depth of field of the next focus. Thereby, there is formed a continuous region of substantially uniform intensity of sonic radiation along the common beam axis. Circuitry is provided for selecting one or more specific foci dependent on the bounds of a selected region to be insonified. Upon reception of sonic energy, circuitry is provided for selecting one or more specific foci as a function of the time of travel of an echo from a subject being observed to approximate a ...

1981-07-07

154

Comparative evolution of various CCD image sensors hardening techniques with ionizing radiation  

International Nuclear Information System (INIS)

This paper reviews various techniques to harden Charged Coupled Device (CCD) sensors and the results after irradiation of three Thomson n buried channel CCDs having a different degree of hardening. It describes the major irradiation effects on CCD performances and it makes a comparison of the results between the different hardening levels. It shows good results on dark voltage after ionizing radiation for TH 7863M device hardened both by design and by operating conditions (MPP mode) with respect to the standard device TH 7863A. The irradiations were performed with "6"0Co or X-ray (10 keV) sources on devices in operating mode. (author). 3 refs., 8 figs.

155

High-efficiency GaAs solar cells on mm and sub-mm grain-size polycrystalline Ge substrates  

Energy Technology Data Exchange (ETDEWEB)

GaAs material and device structure optimization studies on optical-grade, millimeter-and-less grain-size polycrystalline Ge substrates are presented. We discuss the growth of high-quality epitaxial layers across various crystalline orientations of a polycrystalline substrate; this is important for obtaining high-performance solar cells. The GaAs solar cell on n-type poly-Ge substrate is a p-on-n type, with an undoped spacer between the p-emitter and the n-base. An experimental study of dark currents in these junctions, with and without the spacer, as a function of temperature (77K to 288K) is presented; this study suggests that the spacer reduces the tunneling contribution to dark current. In addition, we describe device-structure optimization studies that have led us to achieve an open-circuit voltage (V{sub oc}) exceeding 1 Volt and an AM1.5 efficiency of {approximately}19{percent} for a 4-cm{sup 2}-area GaAs cell on ...

1997-02-01

156

High Efficiency Thin-Fili, GaAs Solar Cells - NASA Technical ...  

Science.gov (United States)

Metal-Semiconductor Solar Cells," J. Appl. Phys. 46,. 1286 (1975). 12) H. B. Kim , G. G. Sweeney and I. S. Heng, "Analysis of ...

157

GaAs REI,IABILITY DATARASE '-r. SACCO, S . C+ ON Z, AItIli ...  

Science.gov (United States)

Direct coupljng between Al and Au metal]jzations can result in an increase in gate resistance due to a metallurgical reaction. (purple plague). An RF life test on ...

158

Formation Energies of Antiphase Boundaries in GaAs and GaP: An ab Initio Study  

UK PubMed Central (United Kingdom)

Electronic and structural properties of antiphase boundaries in group III-V semiconductor compounds have been receiving increased attention due to the potential to integration of optically-active III-V...Full Text Available

159

Development of GaInAsP for GaInAsP/Ge cascade solar cells  

Energy Technology Data Exchange (ETDEWEB)

Quaternary semiconductor compounds are ideal candidates for use in monolithic cascade solar cells because the lattice constant and the bandgap of such compounds can be independently varied. The quaternary semiconductor compound Ga[sub 0.83]In[sub 0.17]As[sub 0.67]P[sub 0.33] not only is lattice matched to GaAs and Ge but also provides a current matched top cell for the GaInAsP/Ge monolithic cascade solar cell. Under concentration of 100 suns, the projected efficiency for such a cell is about 34%. The growth of Ga[sub 0.83]In[sub 0.17]As[sub 0.67]P[sub 0.33] lattice matched to GaAs and Ge has been demonstrated. GaInAsP solar cells have been grown on both GaAs and Ge substrates. A GaInAsP on GaAs solar cell with an active area efficiency of 23.2% for 1 sun, AM 1.5 direct illumination has been prepared. A proposed structure for the GaInAsP/Ge cascade cell is also given.

1992-12-01

160

Review of the application of molecular beam epitaxy for high efficiency solar cell research  

Energy Technology Data Exchange (ETDEWEB)

In the last two years, rapid progress has been made in the energy conversion efficiencies of GaAs solar cells fabricated from molecular beam epitaxy (MBE) material. The efficiencies of cells fabricated from MBE material are now comparable with those fabricated from metal-organic chemical vapor deposition material, even for cells of dimension 2 cmx4 cm. This paper reviews the progress in MBE cell efficiencies. Also discussed is the role oval defects play in GaAs diode and solar cell performance. (orig.).

1991-05-01

161

Quasi-elastic electron scattering by GaAs surface  

International Nuclear Information System (INIS)

Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).

1994-03-20

162

High-optical-quality GaInP and GaInP/AlInP double heterostructure lasers grown on GaAs substrates by gas-source molecular-beam epitaxy  

Science.gov (United States)

By gas-source molecular-beam epitaxy, we obtained a device-quality GaInP epitaxial layer lattice matched to (100)-GaAs substrates, with a photoluminescence efficiency comparable to that of a crystal grown by liquid-phase epitaxy. A GaInP/AlInP double heterostructure laser with a GaInP active layer was fabricated, and pulsed lasing operation was achieved at room temperature for, we believe, the first time.

1989-11-01

163

Ewing's sarcoma of the humerus mimicking fibrous dysplasia on imaging and biological behavior  

International Nuclear Information System (INIS)

We present the case of a 12-year-old girl who presented with a pathological fracture through a benign-appearing osteolytic lesion that was presumed to represent fibrous dysplasia. The fracture healed, and over the next 2.5 years there was further refracturing and healing with progressive osteolysis. A biopsy was performed and revealed Ewing's sarcoma. The disease was locally controlled by neoadjuvant chemotherapy and radiation therapy. The patient is disease free with excellent function 6 years following the discovery of the lesion. We illustrate and discuss the sequence of events. (orig.)

2005-05-01

164

Development of superconducting cryo-electron microscope and its applications  

International Nuclear Information System (INIS)

Recently, a superconducting cryo-electron microscope in which specimens are cooled to the liquid helium temperature (4.2 K) has been developed. The main components and functional features of this new microscope are reported together with application data on polyethylene, poly (4-methyl-1-pentene), valonia cellulose, rock salt, ice crystallites and ceramic superconductor. The resistance to electron radiation damage, of beam-sensitive specimens including polymers has been increased more than ten times. Thus, the microscope has made it possible to take high resolution images and to analyze the crystal-structure of micro-areas. (orig.).

1988-01-01

165

Artificial intelligence: the future in nuclear plant maintenance  

Energy Technology Data Exchange (ETDEWEB)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-12-01

166

Artificial intelligence: the future in nuclear plant maintenance  

International Nuclear Information System (INIS)

The role of robotics and remote handling equipment in future nuclear power plant maintenance activities is discussed in the context of artificial intelligence applications. Special requirements manipulators, control systems, and man-machine interfaces for nuclear applications are noted. Tasks might include inspection with cameras, eddy current probes, and leak detectors; the collection of material samples; radiation monitoring; and the disassembly, repair and reassembly of a variety of system components. A robot with vision and force sensing and an intelligent control system that can access a knowledge base is schematically described. Recent advances in image interpretation systems are also discussed.

1984-09-23

167

Remote sensing monitoring method of hyperspectral and high-resolution for underground coal bed combustion  

Energy Technology Data Exchange (ETDEWEB)

Human beings are confronted with another grievous disaster - coal fire. The monitoring on underground coal bed combustion relied on drilling supervising in the past, but this method is not good. By taking the coal fire of Gulaben mine in Inner Mongolia Autonomous Region as an example, the monitoring methods of underground coal bed combustion were explored based on the hyperspectra and high-resolution remote sensing technology. By employing the OMIS imaging apparatus developed by Shanghai Institute of Technical Physics of Chinese Academy of Sciences, the airborne hyperspectral images and the characteristic spectra of different types were obtained and the temperature was measured synchronously on the ground. Then according to the correlation of DN value of the thermal infrared band and surface temperature, the image information was processed, the spectral features were analyzed, and the surface temperature retrieval model was ...

2007-10-15

168

Real-time neutron radiography at the Iea-R1 m nuclear research reactor  

International Nuclear Information System (INIS)

A LIXI (Light Intensifier X-ray Image) device has been employed in a real-time neutron radiography system. The LIXI is coupled to a video camera and the real-time images can be observed in a TV monitor, and processed in a computer. In order to get the real-time system operational, the neutron radiography facility installed at the IEA-R1 m nuclear research reactor of the IPEN-CNEN/S P has been optimized. The most important improvements were the neutron/gamma ratio, the effective energy of the neutron beam, decrease of the scattered radiation at the irradiation position, and the additional shielding of the video camera. Several one-frame as well as computer processed images are presented. The overall Modulation Transfer Function for the real-time system was obtained from the resolution parameter p = 0:44 +- 0:04 mm; the system sensitivity, evaluated for a Perspex step wedge, was determined and the average ...

2003-06-01

169

Monitoring the effects of land use and cover type changes on soil moisture using remote-sensing data: A case study in China's Yongding River basin  

British Library Electronic Table of Contents (United Kingdom)

We used a radiation-transfer equation estimate of July surface temperatures (Ts) in China's Yongding River basin based on thermal infrared Landsat TM images from 1987 and 2005 and Landsat ETM+ images from 2000. Based upon the Ts-NDVI relationship space, we analyzed the scatterplot of Ts versus NDVI to calculate a temperature-vegetation dryness index (TVDI). We used a linear regression model between soil moisture and TVDI to estimate soil moisture to depths of 10 and 20cm. We produced a land use and cover type map by classification of the Landsat images, and used the map to study the influence of land use and cover type changes on soil moisture. Some areas of farmland in 1987 had been converted into grassland by 2000, and soil moisture mainly increased, with increases ranging from 20 to 60%...

2010-01-01

170

Computed tomography of the orbit  

Energy Technology Data Exchange (ETDEWEB)

In less than a decade computed tomography (CT scanning) had a profound impact on diagnostic radiology. Radiology of the orbit is no exception. As early as 1973, reports published in the radiological literature indicated that this new noninvasive imaging method was a highly effective way of demonstrating intraorbital mass lesions. As CT scanners became widely available, computed tomography became a significant adjunct to ophthalmological diagnosis. Today the main indications for CT scanning of the orbit are: (1) suspected mass lesions, most frequently presenting as exophthalmos, (2) orbital trauma, including foreign bodies, (3) some congenital anomalies, and (4) suspicion of extension into the orbit of extraorbital disease processes. Along with ultrasonography, another new noninvasive imaging technique, CT has replaced a number of more invasive and often less effective diagnostic methods, such as orbital pneumography, venography, and ...

1981-01-01

171

Schottky barrier and homojunction gallium arsenide solar cells  

Energy Technology Data Exchange (ETDEWEB)

New techniques were developed to construct Schottky barrier and homojunction solar cells on GaAs substrates. Schottky barrier metal-semiconductor solar cells were produced for the first time on p-type GaAs substrate using a sputter-deposition method to form the barrier. The sputter deposition of gold or gold/palladium is the key to the method since normal thermal evaporation of gold onto p-type GaAs produces ohmic contacts. The results of this investigation are consistent with the idea that sputter damage produces donor type surface states on GaAs. Barrier heights were measured for both p-type sputtered and n-type thermally evaporated diodes using current-voltage and capacitance-voltage methods. Deep-level transient spectroscopy was used to identify the trap center concentration and energy levels for both diodes in an effort to explain the relatively large dark current in the p-type sputtered diodes. ...

1983-01-01

172

Application of low-dose radiation protocols in survey CT scans  

International Nuclear Information System (INIS)

Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were 80 kV, 10 mA for head, 80 kV, 10 mA for ...

2009-08-01

173

General fundamentals of radiological diagnostics. Specific diagnostic radiology: Throat, mediastinum, diaphragm, mammary gland, infant thorax. 7. rev. ed.  

International Nuclear Information System (INIS)

The fundamentals and the technical application methods of the imaging procedures are discussed in detail with regard to their application in medicine. The development of the X-ray contrast media has led to a better tolerance and a significant reduction of risks. Problems relating to radiation protection and radiation exposure are discussed critically. The general point gives an overview of the radiological examination methods and is meant to deepen the understanding of the special techniques and their rationally determined application. The following special part deals with diagnosing of organs in the region of the neck and the thorax. The general basis is the conventional radiological examination. The great increase in information achieved by means of the new imaging methods becomes clear if we look at the diagnostics of the soft tissue of the neck. Computerized tomography and NMR ...

174

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. ...

1996-12-01

175

Risks and safety aspects related to PET/MR examinations  

International Nuclear Information System (INIS)

The introduction of positron emission tomography (PET)/magnetic resonance (MR) systems into medical practice in the foreseeable future may not only lead to a gain in clinical diagnosis compared to PET/computed tomography (CT) imaging due to the superior soft-tissue contrast of the MR technology but can also substantially reduce exposure of patients to ionizing radiation. On the other hand, there are also risks and health effects associated with the use of diagnostic MR devices that have to be considered carefully. This review article summarizes biophysical and biological aspects, which are of relevance for the assessment of health effects related to the exposure of patients to both ionizing radiation in PET and magnetic and electromagnetic fields in MR. On this basis, some considerations concerning the justification and optimization of PET/MR examinations are presented - as far as this is possible at this very early stage. ...

2009-03-01

176

Digital subtraction angiography with scanning lazer stimulated luminescence  

International Nuclear Information System (INIS)

Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, ...

1985-01-01

177

Digital image intensifier radiography: first experiences with the DSI (Digital Spot Imaging); Moeglichkeiten der digitalen Bildverstaerkerradiographie am Beispiel des Digital Spot Imaging (DSI)  

Energy Technology Data Exchange (ETDEWEB)

We performed a comparative study of digitally and conventionally acquired images in gastrointestinal examinations. Radiation dose and spatial resolution were determined in a water phantom. In 676 examinations with either conventional or digital imaging (system: Diagnost 76, DSI) the number of images and the duration of the fluoroscopy time were compared. 101 examinations with digital as well as conventional documentation were evaluated by using 5 criteria describing the diagnostic performance. The entrance dose of the DSI is 12% to 36% of the film/screen system and the spatial resolution of the DSI may be better than that of a film/screen system with a speed of 200. The fluoroscopy time shows no significant difference between DSI and the film/screen technique. In 2 of 4 examination modes significantly more images were produced by the DSI. With exception of the criterion of edge ...

1995-10-01

178

Optical Images Due to Lenses and Mirrors  

Science.gov (United States)

... Title : Optical Images Due to Lenses and Mirrors. ... Abstract : The properties of real and virtual images formed by lenses and mirrors are reviewed. ...

179

CuPt-type ordering of MOCVD In{sub 0.49}Al{sub 0.51}P.  

Science.gov (United States)

CuPt-type ordering in In{sub 0.49}Al{sub 0.51}P is studied by TEM. The lattice-matched film was grown by MOCVD on a GaAs substrate oriented 10{sup o} off (001) towards [110], at 650 C and 25 nm/min. TEM [110] and [1{bar 1}0] cross-sections (XS) were made by wedge polishing and 2 kV Ar ion milling. In CuPt-type ordering of In{sub 0.52}Ga{sub 0.48}P, alternating In-Ga-In-Ga {l_brace}111{r_brace} planes of group III atoms produce 1/2 {bar 1}11 and 1/2 1{bar 1}1 order spots in the 110 SADP, while the [1{bar 1}0] SADP shows no order spots [1-3]. A few studies have reported this type of order in In{sub 0.49}Al{sub 0.51}P [4]. The 004 BF image of the [1{bar 1}0] XS in Fig. 1 shows uneven light/dark contrast modulation due to phase separation often observed in In{sub 0.52}Ga{sub 0.48}P. There are also light/dark layers marked ML parallel to the film growth plane; such unintentional multilayers have also been observed [5] but their origin is not ...

2002-03-14

180
181

MAGNETIC RESONANCE IMAGING DEVICE  

J-STORE (Japan)

Full Text Available

2010-08-31

182

Some comments on BEIR III  

International Nuclear Information System (INIS)

... organizations irradiation radiation doses radiation effects RADIATIONS.

1982-01-01

183

Radiation technology of wood-plastic composite materials  

International Nuclear Information System (INIS)

... radiation effects RADIATIONS. WOOD-PLASTIC COMPOSITES.

1981-10-02

184
185

Feasibility of ultra-low-dose multislice CT colonography for the detection of colorectal lesions: preliminary experience  

Energy Technology Data Exchange (ETDEWEB)

Our objective was to evaluate the feasibility of ultra-low-dose scanning for multislice CT colonography in the detection of colorectal lesions. Twenty-seven patients (14 men, 13 women) with clinical indication for conventional colonoscopy were recruited. Multislice spiral CT (Somatom Plus 4 Volume Zoom, Siemens, Germany) examinations were performed after standard oral colonoscopic preparation and colonic distension with room air. Images were acquired using 2.5-mm collimation, 3.0-mm slice thickness, standard reconstruction kernel, 140 kVp, and 10 mAs. Supine and prone acquisitions were obtained in all patients. Images were analyzed on a workstation by two gastrointestinal radiologists. Conventional colonoscopy was performed on the same day in all patients and represented the standard of reference. Total radiation exposure was also calculated. All colorectal cancers were correctly identified at CT colonography (9 of 9, ...

2003-06-01

186

Real-time neutron radiography; Radiografia com neutrons em tempo-real  

Energy Technology Data Exchange (ETDEWEB)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the {gamma}-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10{sup 6}n/cm{sup 2}s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/{gamma} ratio {approx} 10{sup 6}n/cm{sup 2}mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame ...

2000-07-01

187

Real-time neutron radiography  

International Nuclear Information System (INIS)

The main objective of the present thesis was develop and get operational a real-time neutron radiography system, at the IPEN-CNEN/SP. This system is installed inside the shielding of an old facility, designed in 1988, for film radiography, which is installed at the beam-hole 08 of the 5 MW, IEA-R1 Nuclear Research Reactor. The most important modifications at the such facility were the increase of the #gamma#-radiation filter thickness, increase of the inner area of the shielding, design of a neutron collimator and a light tight box. The main characteristics of the neutron beam at the irradiation position are: flux: 1 x 10"6n/cm"2s, collimation ratio 70, effective energy 7 meV, diameter 20 cm, neutron/#gamma# ratio #approx# 10"6n/cm"2mrem. The real-time images have been obtained by means of an imaging system that consists of a screen scintillator, a light intensifier, a video camera, a digitizing frame grabber and a ...

2000-01-01

188

Cellular Sources of Transforming Growth Factor-? Isoforms in Early and Chronic Radiation Enteropathy  

Science.gov (United States)

The three mammalian transforming growth factor (TGF)-? isoforms (TGF-?1, TGF-?2, and TGF-?3) differ in their putative roles in radiation-induced fibrosis in intestine and other organs. Furthermore, tissue specificity of TGF-? action may result from temporal or spatial changes in production and/or activation. The present study examined shifts in the cell types expressing TGF-? mRNA relative to TGF-? immunoreactivity and histopathological injury during radiation enteropathy development. A 4-cm loop of rat small intestine was locally exposed to 0, 12, or 21-Gy single doses of x-irradiation. Sham-irradiated and irradiated intestine were procured 2 and 26 weeks after irradiation. Cells expressing the TGF-?1, TGF-?2, or TGF-?3 transcripts were identified by in situ hybridization with digoxigenin-labeled riboprobes. Intestinal wall TGF-? immunoreactivity was measured using computerized image analysis, and structural ...

1998-11-01

189

Time-resolved resonance and linewidth of an ultrafast switched GaAs/AlAs microcavity  

CERN Document Server

We explore a planar GaAs/AlAs photonic microcavity using pump-probe spectroscopy. Free carriers are excited in the GaAs with short pump pulses. The time-resolved reflectivity is spectrally resolved short probe pulses. We show experimentally that the cavity resonance and its width depend on the dynamic refractive index of both the lambda-slab and the lambda/4 GaAs mirrors. We clearly observe a double exponential relaxation of both the the cavity resonance and its width, which is due to the different recombination timescales in the lambda-slab and the mirrors. In particular, the relaxation time due to the GaAs mirrors approaches the photon storage time of the cavity, a regime for which nonlinear effects have been predicted. The strongly non-single exponential behavior of the resonance and the width is in excellent agreement to a transfer-matrix model taking into account two recombination times. The change in width leads to a ...

2009-01-01

190

Ni, Pd, and Pt on GaAs: A comparative study of interfacial structures, compositions, and reacted film morphologies  

Energy Technology Data Exchange (ETDEWEB)

The reactions between (100) GaAs and the near-noble metals Ni, Pd, and Pt have been investigated by application of high-resolution transmission electron microscopy (TEM), energy-dispersive analysis of x rays in the scanning TEM and Rutherford backscattering spectrometry. Emphasis is placed on the evolution of the phase distributions, film compositions, and interface morphologies during annealing at temperatures up to 480 /sup 0/C. The first phase in the Ni/GaAs reaction is shown to have the nominal composition Ni/sub 3/GaAs. Ternary phases of the type Pd/sub x/GaAs are also found to be the dominant products of the Pd/GaAs reaction. Conversely, only binary phases result from the Pt/GaAs reaction. These observations are used to construct isothermal sections of the M--Ga--As thin-film phase diagrams. The behavior of a thin (1--2 nm) native oxide--hydrocarbon layer during the Ni/GaAs, Pd/GaAs, and Pt/GaAs reactions is also investigated. Only the ...

1987-03-01

191

Skeletal remodeling dynamics: New approaches with imaging instrumentation  

Energy Technology Data Exchange (ETDEWEB)

This report of progress and future objectives timetable is based on an included schematic of goals and objectives and the project abstract which is included as Appendix 1. Five matters are summarized in the order of (1) novel methods of calcified bone confocal microscopy and reconstruction image analysis of decalcified beagle and human cortical bone serial sections, (2) macroscopic cross-correlation of beagle and human cortical and cancellous bone fractions with CT analysis, (3) guidance to the most radiobiologically important skeletal regions of interest with the just completed {sup 90}Sr bone tumor map from life time beagle studies, (4) deposition patterns of radioactive agents that participate in apatite crystal nucleation processes in bone and leave radiation-excited electrons trapped in bone mineral, and (5) the budget period timetable. The discovery that beta particles from {sup 166}Ho (T{sub {1/2}} =26 hr, {beta}{sub max} = 1.8 MeV) ...

1991-12-01

192

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...

2008-06-01

193

Applications with a new low-temperature UHV STM at 5 K  

International Nuclear Information System (INIS)

A new dedicated UHV STM for investigations at T#<=#5 K is presented. To achieve such low temperatures and to ensure a high thermal stability, the low-temperature (LT) STM described here has a concentric system of bath cryostats. There are openings for tip and sample exchange at low T, and windows with an infrared radiation shield for optical access, which can both be closed by a door mechanism for LT-STM measurements. Efficient vibration isolation is realized by using spring suspension with eddy current damping. With the 3-d coarse positioning unit any region of interest within 5 mm by 5 mm on the sample is accessible even at 5 K. For short turn-around cycles the sample and tip can both be exchanged at low temperatures. Atomically resolved images of Au(111) at 5 K in UHV demonstrate the excellent performance of this LT STM. As a typical application example the appearance of a charge-density wave on NbSe_2, which occurs below a transition ...

1998-03-01

194

Acceptance testing in digital systems of mammography. Protocols applicability  

International Nuclear Information System (INIS)

Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the ...

197

Java Image I/O for VICAR, PDS, and ISIS  

Science.gov (United States)

This library, written in Java, supports input and output of images and metadata (labels) in the

2011-01-01

198

A non-local approach for image super-resolution using intermodality priors ?  

UK PubMed Central (United Kingdom)

Image enhancement is of great importance in medical imaging where image resolution remains a crucial point in many image analysis algorithms. In this paper, we investigate brain hallucination...Full Text Available

2010-08-01

199

Thin film GaAs solar cells on glass substrates by epitaxial liftoff  

Energy Technology Data Exchange (ETDEWEB)

In this work, we describe the fabrication and operating characteristics of GaAs/AlGaAs thin film solar cells processed by the epitaxial liftoff (ELO) technique. This technique allows the transfer of these cells onto glass substrates. The performance of the lifted-off solar cell is demonstrated by means of electrical measurements under both dark and illuminated conditions. We have also optimized the light trapping conditions in this direct-gap material. The results show that good solar absorption is possible in active layers as thin as 0.32 {mu}m. In such a thin solar cell, the open circuit voltage would be enhanced. We believe that the combination of an epitaxial liftoff thin GaAs film, and nano-texturing can lead to record breaking performance. {copyright} {ital 1997 American Institute of Physics.}

1997-02-01

200

Technology of GaAs metal-oxide-semiconductor solar cells  

Science.gov (United States)

The growth of an oxide interfacial layer was recently found to increase the open-circuit voltage (OCV) and efficiency by up to 60 per cent in GaAs metal-semiconductor solar cells. Details of oxidation techniques to provide the necessary oxide thickness and chemical structure and using ozone, water-vapor-saturated oxygen, or oxygen gas discharges are described, as well as apparent crystallographic orientation effects. Preliminary results of the oxide chemistry obtained from X-ray, photoelectron spectroscopy are given. Ratios of arsenic oxide to gallium oxide of unity or less seem to be preferable. Samples with the highest OVC predominantly have As(+3) in the arsenic oxide rather than As(+5). A major difficulty at this time is a reduction in OCV by 100-200 mV when the antireflection coating is vacuum deposited.

1977-01-01

201

Single-event dynamics of high-performance HBTs and GaAs MESFETs  

Energy Technology Data Exchange (ETDEWEB)

Picosecond charge-collection transients measured for GaAs/AlGaAs HBTs following 3.0 MeV [alpha]-particle and 620 nm picosecond laser excitation reveal charge-collection efficiencies up to twenty-eight times smaller than for GaAs MESFETs, with [approximately]90% of the charge collected within 75 ps of the ionizing event. The small charge-collection efficiency of the HBTs is a consequence of the ultrafast charge-collection dynamics in these devices. The authors show that picosecond laser excitation reproduces nicely the ion-induced transients, providing a valuable tool for the investigation of charge-collection and SEU phenomena in these devices.

1993-12-01

202

MOVPE growth of GaAs and InP based compounds in production reactors using TBAs and TBP  

Energy Technology Data Exchange (ETDEWEB)

Today TBP and TBAs are the compounds which have the highest potential to replace the hydrides arsine and phosphine in the MOVPE process. The authors have demonstrated the entire material system Ga-In-As-P can be grown without any loss of quality using TBP and TBAs not only in one reactor, but in a complete family of reactors. These reactors range from small-scale single wafer R and D reactors to multiwafer Planetary Reactor systems. Both InP based and GaAs based materials could be grown with an excellent quality. Thus all growth processes for III-V devices--long and short wavelength lasers, LEDs, high speed transistors, etc.--can be switched to TBP and TBAs. This will drastically reduce safety hazards and lead to processes that have advantages both from the ecological and economical point of view.

1996-12-31

203

Interface-induced conversion of infrared to visible light at semiconductor interfaces  

International Nuclear Information System (INIS)

Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al_xGa_1_-_xInP_2; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. copyright 1996 The American Physical Society.

204

Integrated optoelectronic materials and circuits for optical interconnects  

International Nuclear Information System (INIS)

Conventional interconnect and switching technology is rapidly becoming a critical issue in the realization of systems using high speed silicon and GaAs based technologies. In recent years clock speeds and on-chip density for VLSI/VHSIC technology has made packaging these high speed chips extremely difficult. A strong case can be made for using optical interconnects for on-chip/on-wafer, chip-to-chip and board-to-board high speed communications. GaAs integrated optoelectronic circuits (IOC's) are being developed in a number of laboratories for performing Input/Output functions at all levels. In this paper integrated optoelectronic materials, electronics and optoelectronic devices are presented. IOC's are examined from the standpoint of what it takes to fabricate the devices and what performance can be expected.

205

GaAs pattern etching with little damage by a combination of Ga"+focused-ion-beam irradiation and subsequent Cl_2 gas etching  

International Nuclear Information System (INIS)

Pattern formation on GaAs by Ga"+ focused-ion-beam (FIB) irradiation and subsequent Cl_2 gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl_2 gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga"+ FIB-assisted Cl_2 etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga"+-ion doses.

206

GaAs pattern etching with little damage by a combination of Ga sup + focused-ion-beam irradiation and subsequent Cl sub 2 gas etching  

Energy Technology Data Exchange (ETDEWEB)

Pattern formation on GaAs by Ga{sup +} focused-ion-beam (FIB) irradiation and subsequent Cl{sub 2} gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl{sub 2} gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga{sup +} FIB-assisted Cl{sub 2} etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga{sup +}-ion doses.

1990-12-15

207

Feasibility investigations of growing and characterizing gallium arsenide crystals in ribbon form. Quarterly progress report 1 Jan-31 Mar 1975  

International Nuclear Information System (INIS)

The feasibility of continuous production of gallium arsenide ribbon single crystals, by passage of a molten zone through boron-oxide encapsulated GaAs feedstock, is being investigated. Polycrystalline GaAs ribbons have been grown in graphite boats by passage of a wide zone through B2O3-encapsulated feed-stock, confined by a quartz cover plate. Failure to remove the encapsulant above its glass transition temperature, however, resulted in cracking of the ribbons on cooling to room temperature. In order to study the crucial zone melting step in isolation from the encapsulation steps of the continuous process, a constrained-zone melting apparatus has been constructed in which the boron oxide serves only as a sealant to suppress arsenic vaporization. Large grained polycrystalline samples have been produced with this apparatus.

208

Characterisation of hole traps in GaAs Fets by DLTS, low frequency noise and g sub M dispersion methods  

International Nuclear Information System (INIS)

Deep level effects in GaAs MOSFET have been characterised in the ohmic channel using DLTS, low frequency excess noise and dispersion technique. An isothermal multi exponential curve fitting method has been devised and implanted into the DLTS system. Multi exponential curve fitting method used to decompose a multi exponential transient into its constituents so that the peak signature can be better characterised for the case whereas several peaks are closely spaced. Low frequency excess noise and dispersion techniques also confirm the trap in signature of the same traps observed in the DLTS measurements. (author)

209

Auger electron spectroscopy studies of GaAs and Si metal-semiconductor structures  

Science.gov (United States)

The use of Auger electron spectroscopy (AES) combined with in situ sputter etching for revealing the metallurgy of the metal-semiconductor interface is presented. The physical basis, measurement techniques, and data interpretation for Auger analysis of thin-film structures are briefly reviewed. Results of a detailed study of an alloyed multilayered contact (Ni/Au-Ge) on n-type epitaxial GaAs are summarized to illustrate how electrical and metallurgical contact properties can be correlated using AES. In addition, the results of a study of the growth kinetics and chemical phase identification of palladium silicide on single-crystal Si is given, as well as the initial results of a study of aluminum-palladium silicide interaction at elevated temperature. (auth)

1975-01-01

210

Auger electron spectroscopy studies of GaAs and Si metal-semiconductor structures  

International Nuclear Information System (INIS)

The use of Auger electron spectroscopy (AES) combined with in situ sputter etching for revealing the metallurgy of the metal-semiconductor interface is presented. The physical basis, measurement techniques, and data interpretation for Auger analysis of thin-film structures are briefly reviewed. Results of a detailed study of an alloyed multilayered contact (Ni/Au-Ge) on n-type epitaxial GaAs are summarized to illustrate how electrical and metallurgical contact properties can be correlated using AES. In addition, the results of a study of the growth kinetics and chemical phase identification of palladium silicide on single-crystal Si is given, as well as the initial results of a study of aluminum-palladium silicide interaction at elevated temperature.

211

University of Michigan workscope for 1991 DOE University program in robotics for advanced reactors  

International Nuclear Information System (INIS)

The University of Michigan (UM) is a member of a team of researchers, including the universities of Florida, Texas, and Tennessee, along with Oak Ridge National Laboratory, developing robotic for hazardous environments. The goal of this research is to develop the intelligent and capable robots which can perform useful functions in the new generation of nuclear reactors currently under development. By augmenting human capabilities through remote robotics, increased safety, functionality, and reliability can be achieved. In accordance with the established lines of research responsibilities, our primary efforts during 1991 will continue to focus on the following areas: radiation imaging; mobile robot navigation; three-dimensional vision capabilities for navigation; and machine-intelligence. This report discuss work that has been and will be done in these areas.

212

Treatment of hepatocellular carcinoma (HCC) with radiolabeled Lipiodol: a preliminary report  

Energy Technology Data Exchange (ETDEWEB)

Fatty acid esters such as Lipiodol or Ethiodol are known to selectively localize in vascular hepatocellular carcinomas (HCC), following intraarterial hepatic administration. Lipiodol was labeled with radioactive /sup 131/I and administered in 47 patients with HCC for both imaging and therapy. The short term preliminary results suggest radiolabeled Lipiodol is effective in eliminating ascites, shrinking the tumor by a high internal radiation dose, and in improving symptomatology of these tumors. In the future, /sup 90/Y, which is a stronger pure beta-emitter (maximum beta energy of 2.27 MeV, a half life of 64 h, and a maximum penetration or beta range of 11mm), than /sup 131/I will be used for more effective treatment of HCC.

1987-12-01

213

Spatially resolved methane band photometry of Jupiter. III - Cloud vertical structures for several axisymmetric bands and the Great Red Spot  

Energy Technology Data Exchange (ETDEWEB)

The paper presents cloud structure models for Jupiter's Great Red Spot, Equatorial and North Tropical Zones, North and South Temperate Zones, and North and South Polar Regions. The models are based on images of Jupiter in three methane bands and nearby continuum radiative transfer calculations include multiple scattering and absorption from three aerosol layers. The model results include the transition in the upper-cloud altitude to 3 km lower altitude from the tropical zones to temperate zones and polar regions, a N/S asymmetry in cloud thickness in the tropical and temperature zones, and the presence of aerosols up to about 0.3 bar in the Great Red Spot and Equatorial Zone. It is concluded that polarization data are sensitive to aerosols in and above the upper cloud layer but insensitive to deeper cloud structure.

1980-02-01

214

Radiopharmaceuticals labelled with positron emitting radionuclides  

International Nuclear Information System (INIS)

A brief survey is presented of the methods of preparation and of the applications of radiopharmaceuticals labelled with short-lived positron radionuclides "1"1C, "1"8F, "1"3N and "1"5O which, thanks to their energy level schemes, short half-life and the 511 keV photon radiation energy are almost ideal tracers in modern nuclear medicine and pharmacology. In conjunction with computerized tomography, they represent one of the most sensitive diagnostic imaging methods, the so-called positron emission tomography. In addition, their incorporation in the molecule of a pharmaceutical does not change the biological and chemical properties of the original molecule unlike those of radiopharmaceuticals labelled with technetium, iodine, etc. (author). 125 refs.

1989-01-01

215

Photo-emission-electron-microscopy for characterization of an operating organic electronic device  

Energy Technology Data Exchange (ETDEWEB)

Photoemission-electron-microscopy (PEEM) is introduced as a tool for the characterization of organic electronic devices. PEEM-measurements are used for imaging as well as for spectroscopic analyses by illumination with light of a Hg-lamp (4.9 eV), a D2 lamp (7.3 eV), and with synchrotron radiation for resonant photoelectron spectroscopy. We determine the charge carrier concentration inside the channel region of the organic device and its lateral distribution. From resonant photoelectron spectroscopy (RPES) we deduce the electronic states which are accessible with the Hg and D2 illumination. Photoelectron-spectroscopy at selected areas ({mu}-PES) gives information on the absolute values of surface potentials in lateral resolution. We are able to perform these studies with applied voltages at the source- and drain-electrode.

2006-01-20

216

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia  

International Nuclear Information System (INIS)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical sings, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure an complex organization. Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction.

1999-04-01

217

Adaptive Radiation Therapy for Localized Mesothelioma with Mediastinal Metastasis Using Helical Tomotherapy  

British Library Electronic Table of Contents (United Kingdom)

The purpose of this study was to compare 2 adaptive radiotherapy strategies with helical tomotherapy. A patient having mesothelioma with mediastinal nodes was treated using helical tomotherapy with pretreatment megavoltage CT (MVCT) imaging. Gross tumor volumes (GTVs) were outlined on every MVCT study. Two alternatives for adapting the treatment were investigated: (1) keeping the prescribed dose to the targets while reducing the dose to the OARs and (2) escalating the target dose while maintaining the original level of healthy tissue sparing. Intensity modulated radiotherapy (step-and-shoot IMRT) and 3D conformal radiotherapy (3DCRT) plans for the patient were generated and compared. The primary lesion and nodal mass regressed by 16.2% and 32.5%, respectively. Adapted GTVs and reduced plan...

2009-01-01

218

Adaptive Management of Liver Cancer Radiotherapy  

British Library Electronic Table of Contents (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance m...

2010-01-01

219

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the ...

2002-07-01

220

Utilization of CTR to measure the evolution of electron-beam microbunching in a self-amplified spontaneous emission (SASE) free-electron laser (FEL)  

International Nuclear Information System (INIS)

We report on the first measurements of the z-dependent evolution of electron-beam microbunching as revealed through coherent transition radiation (CTR) measurements in a visible self-amplified spontaneous emission free-electron laser experiment. The increase in microbunching was detected by tracking the growth of the visible CTR signals as generated from insertable metal mirrors/foils after each of the last three undulators. The same optical imaging diagnostics that were used to track the z-dependent intensity of the undulator radiation (UR) were also used to track the electron beam/CTR information. Angular distribution, beam size, and intensity data were obtained after each of the last three undulators in the five-undulator series, and spectral information was obtained after the last undulator. The exponential growth rate of the CTR was found to be very similar to that of the UR and consistent with simulations using the ...

2001-12-21

221

Production of radiopharmaceuticals for positron emission tomography via laboratory robotics  

International Nuclear Information System (INIS)

The production of radiopharmaceuticals used in positron emission tomography (PET) can require large amounts of activity at the start of synthesis in order to yield sufficient labeled material for clinical studies. Several investigators have developed remote and automated systems for the routine production of PET radiopharmaceuticals in order to reduce radiation exposure to personnel. Such devices, however, suffer from limited flexibility and can be relatively complicated in design. These systems are also limited to the production of a single or a few closely related compounds. Furthermore, changes in chemistry would require considerable modifications in hardware and/or software in order to bring the device back into operation. To circumvent the above limitations associated with the remote production of PET radiopharmaceuticals, the authors have investigated the use of laboratory robotics as a flexible alternative to the synthesis of several short-lived ...

1987-11-15

222

On the determination of the dose-area product during X-ray examinations  

International Nuclear Information System (INIS)

Despite its great usefulness in the performance of the recording procedures prescribed by the X-Ray Ordinance the dose-area product is much less frequently measured for X-ray exposures than during fluorscopic examinations. The great multitude of measuring units, mainly on account of different scales of the measuring equipments themselves, is a cause of uncertainty in clinical routine and should be eliminated as far as the circumstances would permit. As the determination of the organ dose is relevant only in very few cases and does not necessarily require previous measurements of the dose-area product, these are of limited practical value in the assessment of individual radiation exposures during radiographic examinations. The measurements may, however, be very helpful in determinations of the radiation dose to the total population, if the future retrievability of the values obtained is ensured. In addition to some measuring values showing past ...

223

Measurement of dose-area product in diagnostic radiology as a method of assessing the radiation exposure. (Results, experience, proposals for improvement, recommendations relating to radiological protection). Report of an expert meeting  

International Nuclear Information System (INIS)

The fundamental recommendations of the ICRP issued in its publication of 1990 stipulate the general principle of performance of dose measurements at regular intervals in the field of diagnostic radiology, for the purpose of equipment performance checking and optimization of radiological protection. In response to this requirement, the Federal Ministry, in cooperation with experts and the competent supervising authorities, has issued an order to install dose-area-product meters in angiographic examination systems, imaging systems and fluoroscopic screen devices primarily used for examining infants and children up to the age of 12. This is done in response to reported cases of adverse effects of radiation exposure and the high priority given to radiological protection in the examination of infants and children. In 1992, an expert group was convened to discuss and elaborate instructions for including dose-area product measurement in the dosimetry ...

224

Determination of the initial energy in computerized tomography with proton beams; Determinacao da energia inicial em tomografia computadorizada com feixe de protons  

Energy Technology Data Exchange (ETDEWEB)

In earliest works devoted to proton computed tomography it was shown that the advantage of pCT image reconstruction appears when the energy is close to the Bragg peak region, since the proton passes the object. This effect provided by the Bragg peak makes the computerized tomography with protons possible. However, when decreasing the initial proton energy, with the increase of the irradiation dose, there are two effects that work simultaneously in opposite ways. First, the energy loss of a proton in an object becomes bigger at small initial energy. At the same time decreasing of the proton energy results in the increase of the energy straggling, requiring a larger number of protons. In this work the radiation dose dependence on the proton initial energy was studied using analytical formulas and computer simulations. The investigation determined that the radiation dose practically does not depend on the initial energy, ...

2007-07-01

225

Concepts of radiotherapy treatment planning  

International Nuclear Information System (INIS)

Full text: Radiotherapy treatment planning (RTP) relies heavily on medical imaging. Until recently, the most important planning tool was the treatment simulator. The kilovoltage radiographic capabilities in a treatment simulator enabled the boundaries of treatment fields to be visualized with respect to bony anatomic landmarks. Perhaps the most important advance in treatment planning in recent years is the ability to visualize the passage of the beams with respect to a more accurate geometrical representation of the tumor and other soft tissue structures. This 'virtual simulation' uses a computer-based representation of a patient to determine the extent of the disease and the location of radiation sensitive normal tissue. Computer tomographic (CT) imaging produces a high-resolution three-dimensional representation of anatomy that can be correlated with other image sets such as magnetic resonance ...

2000-12-01

226

Detection of high-frequency radiation sources during the 2004 Parkfield earthquake by a matched filter analysis  

Science.gov (United States)

Introduction Uchide and Ide [SSA Spring Meeting, 2009] proposed a new framework for studying the scaling and overall nature of earthquake rupture growth in terms of cumulative moment functions. For better understanding of rupture growth processes, spatiotemporally local processes are also important. The nature of high-frequency (HF) radiation has been investigated for some time, but its role in the earthquake rupture process is still unclear. A wavelet analysis reveals that the HF radiation (e.g., 4 - 32 Hz) of the 2004 Parkfield earthquake is peaky, which implies that the sources of the HF radiation are isolated in space and time. We experiment with applying a matched filter analysis using small template events occurring near the target event rupture area to test whether it can reveal the HF radiation sources for a regular large earthquake. Method We design a matched filter for multiple components and ...

2009-12-01

227

The polarized electron gun for the SLC  

International Nuclear Information System (INIS)

A new polarized electron gun for use on the SLC at SLAC has been built and tested. It is a diode gun with a laser driven GaAs photocathode. It is designed to provide short (2ns) pulses of 10 A at 160 kV at 120 Hz. The design features of the gun and results from a testing program on a new and dedicated beam line are presented. Early results from operation on the SLC will also be shown.

1992-03-24

228

Solar cells  

Energy Technology Data Exchange (ETDEWEB)

The article is the second part of a review dealing with latest developments in the area of solar cell technologies and application. Physical principles, design and efficiency as well as advantages and disadvantages of GaAs- and CdS-solar cells are described. Power generation solar cell systems with voltage converters, combined solar cell/solar collector systems and thermoelectric solar systems are presented in the second part of the article.

1983-04-01

229

Local Structures and Interface Morphology of InGaAsN Thin Films Grown on GaAs  

Energy Technology Data Exchange (ETDEWEB)

The compound semiconductor system InGaAsN exhibits many intriguing properties which are particularly useful for the development of innovative high efficiency thin film solar cells and long wavelength lasers. The bandgap in these semiconductors can be varied by controlling the content of N and In and the thin films can yet be lattice-matched to GaAs. In the present work, x-ray absorption fine structure (XAFS) and grazing incidence x-ray scattering (GIXS) techniques have been employed to probe the local environment surrounding both N and In atoms as well as the interface morphology of InGaAsN thin films epitaxially grown on GaAs. The soft x-ray XAFS results around nitrogen K-edge reveal that N is in the sp{sup 3} hybridized bonding configuration in InGaAsN and GaAsN, suggesting that N impurities most likely substitute for As sites in these two compounds. The results of In K-edge XAFS suggest a possible trend of a slightly larger coordination ...

1999-02-23

230

Growth and electronic properties of two-dimensional systems on (110) oriented GaAs  

Energy Technology Data Exchange (ETDEWEB)

As the only non-polar plane the (110) surface has a unique role in GaAs. Together with Silicon as a dopant it is an important substrate orientation for the growth of n-type or p-type heterostructures. As a consequence, this thesis will concentrate on growth and research on that surface. In the course of this work we were able to realize two-dimensional electron systems with the highest mobilities reported so far on this orientation. Therefore, we review the necessary growth conditions and the accompanying molecular process. The two-dimensional electron systems allowed the study of a new, intriguing transport anisotropy not explained by current theory. Moreover, we were the first growing a two-dimensional hole gas on (110) GaAs with Si as dopant. For this purpose we invented a new growth modulation technique necessary to retrieve high mobility systems. In addition, we discovered and studied the metal-insulator transition in thin bulk p-type ...

2005-07-01

231

Discordant expression and variable numbers of neighboring GGA- and GAA-rich triplet repeats in the 3' untranslated regions of two groups of messenger RNAs encoded by the rat polymeric immunoglobulin receptor gene.  

UK PubMed Central (United Kingdom)

An unusual S1-nuclease sensitive microsatellite (STMS) has been found in the single copy, rat polymeric immunoglobulin receptor gene (PIGR) terminal exon. In Fisher rats, elements within or beyond the...Full Text Available

1995-04-11

232

Comparison of Al{sub 0.51}In{sub 0.49}P and Ga{sub 0.51}In{sub 0.49}P window layers for GaAs and GaInAsP solar cells  

Energy Technology Data Exchange (ETDEWEB)

Two window layer materials, Al{sub 0.51}In{sub 0.49}P (E{sub g} = 2.3 eV) and Ga{sub 0.51}In{sub 0.49}P (E{sub g} = 1.88 eV) were compared for gas-source and solid-source MBE grown GaAs and Ga{sub 0.84}In{sub 0.16}As{sub 0.68}P{sub 0.32} (E{sub g} = 1.55 eV) solar cells. Due to the wider band-gap of Al{sub 0.51}In{sub 0.49}P, the increased spectral response was observed for both GaAs and Ga{sub 0.84}In{sub 0.16}As{sub 0.68}P{sub 0.32} material based solar cells. In the case of the GaAs cells, the short-circuit current density was observed to increase from 32.5 mA/cm{sup 2} to 34.4 mA/cm{sup 2} with the Al{sub 0.51}In{sub 0.49}P window layer at AM0. Similar improvement was observed for the Ga{sub 0.84}In{sub 0.16}As{sub 0.68}P{sub 0.32} solar cells.

1997-12-31

233

A multidisciplinary study investigating radiotherapy in Ewing's sarcoma: end results of POG no. 8346  

International Nuclear Information System (INIS)

Purpose: To determine if involved field radiation (IF) is equivalent to standard whole bone radiation (SF) in local tumor control; to establish patterns of failure following treatment; and to determine response, event-free survival (EFS), and overall survival rates from multidisciplinary therapy in Ewing's sarcoma. Methods and Materials: Between 1983 and 1988, 184 children with Ewing's sarcoma were enrolled onto Pediatric Oncology Group 8346 (POG 8346). A total of 178 (97%) met eligibility criteria; 6 had pathology other than Ewing's sarcoma. Induction chemotherapy of cyclophosphamide/doxorubicin (adriamycin )(C/A) x 12 weeks was followed by local treatment either surgery or radiation therapy and C/A, dactinomycin, and vincristine for 50 weeks. Resection was advised for patients with small primary tumors if accomplished without functional loss. Forty patients were randomized to receive SF, whole bone ...

1998-08-01

234

View larger image for ISS022-E-26137 - Earth Sciences and Image ...  

Science.gov (United States)

The Asarco-Mission complex (image left) is an active producer of copper and molybdenum (important in making steel and other metal alloys), ...

235

Digital processing to improve image quality in real-time neutron radiography  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

236

Digital processing to improve image quality in real-time neutron radiography  

International Nuclear Information System (INIS)

Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction ...

1985-01-01

237

Advances in Imaging of Vertebral and Spinal Cord Injury  

UK PubMed Central (United Kingdom)

Background/Objectives:Imaging technology is an important part of the diagnosis and management of spinal trauma. Indications and findings in post-traumatic imaging of the vertebral...Full Text Available

2010-04-01

238

3 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

performs Gaussian pyramid operation on an image performs expand pyramid operation on an image mosaic two images using 'reduce' and 'expand' pyramid ...

239

(Hadamard transform imaging)  

Science.gov (United States)

This report describes the design of, and image reconstruction capacity of a Hadamard Raman Microscopic imager. Microscopy of benzoic acid and graphite electrodes, as well as electrophoretic blotting, are described. (CBS)

1990-01-01

241
242

Animal Models for Radiation Injury, Protection and Therapy  

Science.gov (United States)

... radiation during clinical therapy and exposures due to radiation accidents or attacks, in which the doses are uncontrolled ... only be used off-label in victims of radiation accidents or attacks. The idea...

243
245

Simple fractal method of assessment of histological images for application in medical diagnostics  

UK PubMed Central (United Kingdom)

We propose new method of assessment of histological images for medical diagnostics. 2-D image is preprocessed to form 1-D landscapes or 1-D signature of the image contour and then their complexity is...Full Text Available

246
253

Images of photoreceptors in living primate eyes using adaptive optics two-photon ophthalmoscopy  

UK PubMed Central (United Kingdom)

In vivo two-photon imaging through the pupil of the primate eye has the potential to become a useful tool for functional imaging of the retina. Two-photon excited fluorescence images...Full Text Available

254

Image Engine: an object-oriented multimedia database for storing, retrieving and sharing medical images and text.  

UK PubMed Central (United Kingdom)

This paper describes Image Engine, an object-oriented, microcomputer-based, multimedia database designed to facilitate the storage and retrieval of digitized biomedical still images, video, and text...Full Text Available

1993-01-01

262

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

263

Magnetic resonance imaging in the evaluation of pneumonia; Nachweis von pneumonischen Infiltraten mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) of the lung is challenging because of substantial drawbacks. However, lung pathologies that are associated with increased attenuation values in CT enhance visualization in MRI: proton density is increased and tissue-air interfaces, resulting in susceptibility artifacts, are reduced in pneumonia, pneumonitis, edema, and carcinoma. On the other hand, many lung diseases result in shortness of breath, so that patients cannot hold their breath for long periods. Therefore, fast imaging techniques are required which should also allow for high spatial resolution so that small lesions can be detected. Calcifications and air pockets within lesions are not readily recognized with MRI. Thin section CT is standard for the diagnosis of pneumonia. With parallel imaging techniques, MRI examination of the lungs can be performed with short periods of breath holding, which allow for sub-centimeter resolution ...

2006-04-15

264

Real time neutron radiography using a Lixi neutron imaging device  

Energy Technology Data Exchange (ETDEWEB)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-15

265

Real time neutron radiography using a Lixi neutron imaging device  

International Nuclear Information System (INIS)

A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain ...

1986-01-01

266

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This ...

2010-01-01

267

Understanding and predicting soot generation in turbulent non-premixed jet flames.  

Energy Technology Data Exchange (ETDEWEB)

This report documents the results of a project funded by DoD's Strategic Environmental Research and Development Program (SERDP) on the science behind development of predictive models for soot emission from gas turbine engines. Measurements of soot formation were performed in laminar flat premixed flames and turbulent non-premixed jet flames at 1 atm pressure and in turbulent liquid spray flames under representative conditions for takeoff in a gas turbine engine. The laminar flames and open jet flames used both ethylene and a prevaporized JP-8 surrogate fuel composed of n-dodecane and m-xylene. The pressurized turbulent jet flame measurements used the JP-8 surrogate fuel and compared its combustion and sooting characteristics to a world-average JP-8 fuel sample. The pressurized jet flame measurements demonstrated that the surrogate was representative of JP-8, with a somewhat higher tendency to soot formation. The premixed flame measurements revealed that flame temperature has a ...

2010-10-01

268

Magnetic resonance imaging in childhood epilepsy  

International Nuclear Information System (INIS)

The suitability of MR imaging versus computerized tomography in observation of brain development disorders in children are compared. 13 refs.

269

Esters useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

1981-08-18

270

Esters useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing esters useful as brain imaging agents are disclosed. The formula of these compounds are presented.

271

Amides useful as brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula

1981-07-21

272

Amides useful as brain imaging agents  

International Nuclear Information System (INIS)

Certain radioiodine containing amides useful as brain imaging agents are disclosed. The compounds of the subject invention are represented by the formula.

273

High-efficiency, thin-film- and concentrator solar cells from GaAs. Final report; High-efficiency, Duennschicht- und Konzentrator-Solarzellen aus Galliumarsenid. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

Main topic of the project was the manufacturing of highly efficient GaAs-solar cells and the fabrication of concentrator cells. During this process significant progress was made with the material preparation, the solar cell technology and the material and process characterisation. This succeeded in the following efficiencies: - GaAs solar cell made by MOVPE technology: 22.9% on 4 cm{sup 2} (AM1.5g) - GaAs solar cell made by LPE-ER process: 22.8% on 4 cm{sup 2} (AM1.5g) - GaAs concentrator solar cell made by LPE-ER process: 24.9% at C=100xAM1.5d - GaAs concentrator module with fresnel lenses: Module efficiency 20.1% (under irradiation of 793 W/m{sup 2}). Another main focus was the epitaxy of GaAs on Si substrate. Two different approaches were investigated. Together with the cooperation partner ASE, Heilbronn a selective growth technology was developed that led to a decreased crack ...

1996-10-01

274

Image-enhancement applications at the Lawrence Livermore National Laboratory  

Energy Technology Data Exchange (ETDEWEB)

A diverse set of digital image-processing applications exists at the Lawrence Livermore National Laboratory. While many of these include some sort of image analysis or restoration, virtually all of them require image-enhancement procedures. In this paper we describe the principal image-processing facility at the Laboratory, followed by a discussion of several of the major image-processing application areas.

1982-06-01

275

Statistical cut-off criterion  

International Nuclear Information System (INIS)

... radiation effects human populations low dose irradiation neoplasms radiation

1980-01-01

276

Radiation protection and the management of radioactive waste in the oil and gas industry  

CERN Document Server

Radiation protection and the management of radioactive waste in the oil and gas industry

2003-01-01

278

Higher harmonics of spontaneous radiation of ultrarelativistic channeled particles  

International Nuclear Information System (INIS)

The case of spontaneous radiation of channeled ultrarelativistic particles is considered when the dipolarity condition is not satisfied. The change of the particle longitudinal velocity affecting the maximum radiation frequency is included. The angular and frequency characteristics of the radiation for superhigh energies are studied for the first time. It is shown that there is an optimum energy at which the radiation density is maximum. The influence of the angle at which electrons enter a crystal and of the beam divergence on the radiation is investigated. The problem of quasichanneled particle radiation and also the radiation in axis-plane transitions are considered. (author).

1980-06-01

280

Contribution to the radiation preparation of wood-plastic materials. Pt. 7  

International Nuclear Information System (INIS)

... odd nuclei organic compounds radiation effects radioisotopes synthesis

1974-01-01

281

Contribution to the radiation preparation of wood-plastic materials. Pt. 6  

International Nuclear Information System (INIS)

... compounds polymers polyolefins polyvinyls radiation effects SYNTHESIS.

1974-01-01

282

Contribution to the radiation preparation of wood-plastic materials Pt. 3  

International Nuclear Information System (INIS)

... compounds plants radiation effects radioisotopes reaction kinetics trees

1974-01-01

283

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy  

CERN Document Server

Compact Proton and Carbon Ion Synchrotrons for Radiation Therapy

2002-01-01

284

? j -  

Science.gov (United States)

duced and spontaneous radiation. The amount of polarization is ... of the induced and spontaneous radiation patterns. Therefore ...

285

Systematics of average radiative width of heavy nuclides  

Energy Technology Data Exchange (ETDEWEB)

Systematics of neutron capture radiative width were studied in the target element range from Th to Cm. Reduced radiative widths were analyzed with a simple radiative width formula based on E1 transition. Average radiative width is presented with the standard deviation of 15%. (author)

1999-03-01

286

An Effective Method of Image Retrieval using Image Mining Techniques  

CERN Document Server

The present research scholars are having keen interest in doing their research activities in the area of Data mining all over the world. Especially, [13]Mining Image data is the one of the essential features in this present scenario since image data plays vital role in every aspect of the system such as business for marketing, hospital for surgery, engineering for construction, Web for publication and so on. The other area in the Image mining system is the Content-Based Image Retrieval (CBIR) which performs retrieval based on the similarity defined in terms of extracted features with more objectiveness. The drawback in CBIR is the features of the query image alone are considered. Hence, a new technique called Image retrieval based on optimum clusters is proposed for improving user interaction with image retrieval systems by fully exploiting ...

2010-01-01

287

High-resolution beta imaging; L'imagerie beta haute resolution  

Energy Technology Data Exchange (ETDEWEB)

For many years, {beta} radioactivity has been used to label molecules and follow them in various biological processes. {beta} imaging is obtained by autoradiography. Classically made on films or on photographic emulsions, autoradiography is now supplanted by radio-imagers which are very performing. The phosphor-imager, {beta}-imager and {mu}-imager are the systems mainly used today and their operating principles and properties are compared. The great advantages of these imagers are: their rapidity to obtain results and their reliability for absolute quantification. All emitters ({beta}{sup -}, {beta}{sup -} -{gamma} and {beta}{sup +}) are detectable as well as the gamma emitters of nuclear medicine, by means of their low energy electrons ejected during y emission. Phosphor-imager is well suited to energetic tracers and large series of ...

2007-04-15

288

Ultrafast carrier dynamics of InGaAsN and InGaAs single quantum wells  

International Nuclear Information System (INIS)

Striking differences in differential reflectance and carrier relaxation in In0.4Ga0.6As and In0.4Ga0.6As0.98N0.02 single quantum wells (SQWs) were studied using ultrafast time-resolved photoreflectance. Even with extremely thin SQW of only 60 A within 3000 A wide GaAs confining layers, negative and positive differential reflectance was observed for the excitation photon energy far above the bandgaps at 820 and 880 nm for both samples. Due to absorption by the GaAs confining layer, the peak differential reflectance pumped at 820 nm is an order of magnitude larger than that pumped at 880 nm; and it is larger for InGaAs SQWs than for InGaAsN SQWs. The shorter carrier lifetimes of these samples result from carrier-carrier scattering as pumped at both wavelengths. The longer carrier lifetime as pumped at 880 nm is due to hot phonon decay in InGaAs but may be due to stimulated emission in InGaAsN. The results reveal that the carrier dynamics is ...

2008-04-21

289

The potential of III-V semiconductors as terrestrial photovoltaic devices  

Energy Technology Data Exchange (ETDEWEB)

III-V semiconductors, GaAs and in particular InGaP, are used in many different electronic applications, such as high power and high frequency devices, laser diodes and high brightness LED. Their direct bandgap and high reliability make them ideal candidates for the realisation of high efficiency solar cells: in the past years they have been successfully used as power sources for satellites in space, where they are able to produce electricity from sunlight with an overall efficiency of around 30%. Nowadays, the use of arsenides and phosphides as photovoltaic (PV) devices is confined only to space applications since their price is much higher than conventional Si flat panel modules, the leading PV market technology. But with the introduction of multijunction solar cells capable of operating in high concentration solar light, the area and, therefore, the cost of these cells can be reduced and will eventually find an application and market also on Earth. This article ...

2006-07-01

290

The characteristics of ion-beam-induced spontaneous etching of GaAs by low-energy focused ion beam irradiation  

International Nuclear Information System (INIS)

We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ion energy of 3 keV after annealing at 400degC. (author).

291

Surface Fermi level engineering: Or there's more to Schottky barriers than just making diodes and field effect transistor gates  

Science.gov (United States)

Surface scientists argue about the fundamental nature of Schottky barriers, or more precisely what determines the location of the Fermi level at semiconductor surfaces and interfaces. Electrical and materials engineers worry about how to make Schottky barrier diodes and gates to field effect transistors and the control of barrier heights. There is some interesting middle ground in which the location of the surface and interface Fermi level can, for example, determine semiconductor doping characteristics during crystal growth. The authors will discuss several interesting and well known examples of doping characteristics which are still somewhat mysterious. Specifically, they address the following question: (1) why is Ge doped GaAs p type when grown from Ga melts but n type when grown from Au melts (2) why is low resistivity p type ZnSe, AlAs, and AlGaInP hard to make, and more importantly, how can the problem be fixed. In addition they describe how this concept ...

292

Room-temperature cw operation of InGaP/InGaAlP visible light laser diodes on GaAs substrates grown by metalorganic chemical vapor deposition  

Energy Technology Data Exchange (ETDEWEB)

Room-temperature cw operation for InGaP/InGaAlP double heterostructure (DH) laser diodes on GaAs substrates was achieved for the first time. The DH wafers were grown by low-pressure metalorganic chemical vapor deposition using methyl metalorganics. A lasing wavelength of 679 nm and a threshold current of 109 mA at 24C were obtained for an inner stripe structure laser diode with a 250- m-long and 7- m stripe geometry. The laser operated at up to 51C. The characteristic temperature T0 was 87 K at around room temperature. The lowest threshold current density, 5.0 kA/cmS, was obtained with a 20- m stripe width laser diode under room-temperature pulsed operation.

1986-01-20

293

Positioning of self-assembled InAs quantum dots by focused ion beam implantation  

International Nuclear Information System (INIS)

Self-assembled quantum dots (QDs) are envisioned as building blocks for realization of novel nanoelectronic devices, for which the site-selective growth is highly desirable. This thesis presents a successful route toward selective positioning of self-assembled InAs QDs on patterned GaAs surface by combination of in situ focused ion beam (FIB) implantation and molecular beam epitaxy (MBE) technology. First, a buffer layer of GaAs was grown by MBE before a square array of holes with a pitch of 1-2 #mu#m was fabricated by FIB implantation of Ga and In, ions respectively. Later, an in-situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by FIB. The influence of ion dose, annealing parameters and InAs amount was investigated in this work. With optimized parameters, more than 50 % single dot occupancy per hole is achieved. Furthermore, the photoluminescence spectra from ...

2006-07-01

294

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the X-ray intensity ratios are not strongly affected by X-ray absorption; and therefore, the conditions necessary ...

1990-01-01

295

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the X-ray intensity ratios are not strongly affected by X-ray absorption; and therefore, the conditions necessary for ...

1989-06-01

296

MOCVD-grown Al /SUB 0. 5/ In /SUB 0. 5/ P-Ga /SUB 0. 5/ In /SUB 0. 5/ P double heterostructure lasers optically pumped at 90 K  

Energy Technology Data Exchange (ETDEWEB)

Undoped Al /SUB 0.5/ In /SUB 0.5/ P-Ga /SUB 0.5/ In /SUB 0.5/ P double heterostructure was grown on (100) GaAs by metalorganic chemical-vapor deposition for the first time. A mirror-like grown surface was obtained. Over ten-times stronger photoluminescence-intensity was gained from the sandwiched Ga /SUB 0.5/ In /SUB 0.5/ P-layer, than that from a single epitaxially-grown Ga /SUB 0.5/ In /SUB 0.5/ P-layer on (100) GaAs, indicating that high-quality Al /SUB 0.5/ In /SUB 0.5/ P-Ga /SUB 0.5/ In /SUB 0.5/ P heterointerfaces are formed in the double heterostructure. A lasing action by optical pumping with an argon ion laser was observed in the double heterostructure at 90 K. The observed stimulated emission wavelength was 6470 A.

1982-12-01

297

Interface-induced conversion of infrared to visible light at semiconductor interfaces  

Science.gov (United States)

Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al{sub {ital x}}Ga{sub 1{minus}{ital x}}InP{sub 2}; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. {copyright} {ital 1996 The American Physical Society.}

1996-08-01

298

Generation of ammonia plasma using a helical antenna and nitridation of GaAs surface  

International Nuclear Information System (INIS)

Using the ammonia (NH3) plasma generated by a helical antenna surrounded by two magnetic coils, the transition of the discharge mode from low-density plasma to high-density one was observed. At the transition, the emission intensities from the H atoms and NH radicals especially increased in the optical emission spectroscopy, while the intensities of the other emission lines also increased abruptly. The nitridation of gallium arsenide (GaAs) surface was performed using the high-density NH3 plasma, and the properties of the nitrided surface layer were compared with those nitrided by high-density N2 plasma using the same apparatus. From the spectroscopic ellipsometry measurements, the thickness of the nitrided layer was estimated to be 16-18 nm, while that by N2 was 3-4 nm. From the Ga 3d spectra, the contamination with oxygen in the nitridation layer by NH3 plasma was less than that by N2 plasma.

2003-05-15

299

Exploring the 2D to 3D dimensionality crossover in thin iron films  

Energy Technology Data Exchange (ETDEWEB)

The temperature dependence of the spontaneous magnetization of epitaxial iron films with a thickness ranging from d=20 to 200nm has been measured. The films are grown on GaAs (100) substrates which are covered by a 150nm thick silver (100) buffer layer. For three-dimensional BCC iron it was observed already in 1929 that saturation of the spontaneous magnetization for T->0 is perfectly described by a T{sup 2} power law. On the other hand, for thin two-dimensional (2D) iron films a T{sup 3/2} law has been established in many recent experimental investigations. In our iron films grown on diamagnetic silver, this dimensionality change occurs at a thickness between d=100 and 200nm. Comparison of the here-observed T{sup 3/2} coefficients with those on iron films grown on paramagnetic tungsten (110) shows that the 2D interactions are {approx}20 times larger in the films on tungsten. Recent results on Fe films which are grown directly on GaAs ...

2006-05-15

300

Comparative study of phase stability and film morphology in thin-film M/GaAs systems (M = Co, Rh, Ir, Ni, Pd, and Pt)  

Energy Technology Data Exchange (ETDEWEB)

To attain reproducible and stable contacts to compound semiconductor devices, it is necessary to achieve thermodynamically stable phases after the reaction of metals with the compound semiconductor. In this study, the final phases produced by the reactions between GaAs and thin metal films of Co, Rh, Ir, Ni, Pd, and Pt have been investigated. They are identified as MGa for M = Co, Rh, Ni, Pd, and Pt, monoarsenides of Co and Ni, diarsenides of Rh, Ir, Pd, and Pt, and Ir/sub 3/Ga/sub 5/. These phases, if deposited directly onto GaAs, will produce thermally stable contacts. In addition to the identification of these stable phases, analyses of the products of thin-film M/GaAs reactions by transmission electron microscopy, x-ray diffraction, and Rutherford backscattering spectrometry reveal the distribution, grain size, and crystallographic texture of these end phases. Trends in these observations across the six metal/GaAs reactions studied are ...

1987-09-01

301

Al[sub 0. 3]Ga[sub 0. 7]As/GaAs heterojunction tunnel diode for tandem solar cell applications  

Energy Technology Data Exchange (ETDEWEB)

A p[sup +]-Al[sub 0.3]Ga[sub 0.7]As/n[sup +]-GaAs heterojunction tunnel diode was fabricated using Atomic Layer Epitaxy (ALE) growth technique. Background carbon doping of [similar to]10[sup 20] cm[sup [minus]3] was achieved in the p-side of the diode by optimizing growth conditions such as V/III ratio, exposure times to reactant gases, and growth temperature. In the n-side of the diode GaAs was doped with silane and doping concentrations as high as 7[times]10[sup 18] cm[sup [minus]3] were also achieved. The dopants are chosen to satisfy the high levels and low diffusion requirements. The diode can be used to interconnect the high and low band-gap cells in the AlGaAs/GaAs cascade solar cell structure. The reactor used in this investigation is a commercial MOCVD system which has been specially modified for dual operation of ALE and MOCVD growth modes.

1994-06-30

302

Xeroradiography and computed radiography comparative study on diagnosis for breast cancer  

Energy Technology Data Exchange (ETDEWEB)

Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good diagnostic ...

1990-04-01

303

Xeroradiography and computed radiography comparative study on diagnosis for breast cancer  

International Nuclear Information System (INIS)

Xeroradiography (XR) was retrospectively compared with a newly developed computed radiography (FCR) for diagnostic availability for breast cancer. FCR provides with the image processed by a computer. Subjects were 65 breast cancer patients for XR and 51 for FCR. Both methods were performed preoperatively. No significant difference was observed in distribution of age between the two groups but the average tumor size in XR group was larger than that in FCR group. Tumor shadow appeared in 44 of 65 xeromammograms (67.7%) and in 34 of 51 computed radiograms (66.7%). Microcalcification was detected in 27 of 65 xeromammograms (41.5%) and in 21 of 51 computed radiograms (41.2%). Consequently, diagnosis of breast cancer could be achieved in 47 of 65 patients (72.3%, established: 39, suspective: 8) through XR and in 41 of 51 (80.4%, established: 33, suspected: 8) through FCR. Thus FCR is thought to be more useful for breast cancer because it not only offers good diagnostic ...

1990-01-01

304

The safety issues of medical robotics  

International Nuclear Information System (INIS)

In this paper, we put forward a systematic method to analyze, control and evaluate the safety issues of medical robotics. We created a safety model that consists of three axes to analyze safety factors. Software and hardware are the two material axes. The third axis is the policy that controls all phases of design, production, testing and application of the robot system. The policy was defined as hazard identification and safety insurance control (HISIC) that includes seven principles: definitions and requirements, hazard identification, safety insurance control, safety critical limits, monitoring and control, verification and validation, system log and documentation. HISIC was implemented in the development of a robot for urological applications that was known as URObot. The URObot is a universal robot with different modules adaptable for 3D ultrasound image-guided interstitial laser coagulation, radiation seed implantation, laser resection, ...

2001-08-01

305

The jet-powered optical nebula of Cygnus X-1  

CERN Document Server

We present H-alpha and [O III] (5007 Angstroms) images of the nebula powered by the jet of the black hole candidate and microquasar Cygnus X-1, observed with the 2.5m Isaac Newton Telescope (INT). The ring-like structure is luminous in [O III] and there exists a thin outer shell with a high [O III] / H-alpha flux ratio. This outer shell probably originates in the collisionally excited atoms close to the front of the bow shock. Its presence indicates that the gas is shock excited as opposed to photoionised, supporting the jet-powered scenario. The shock velocity was previously constrained at 20 = 100 km/s (1 sigma confidence) based on a comparison of the observed [O III] / H-alpha ratio in the bow shock with a number of radiative shock models. From this we further constrain the time-averaged power of the jet: P_Jet = (4 - 14)*10^36 erg/s. The H-alpha flux behind the shock front is typically 4*10^-15 erg/s/cm^2/arcsec^2, and we estimate an upper ...

2007-01-01

306

The infrared-dominated jet of 3C401  

CERN Document Server

We present a Hubble Space Telescope image of the FRII radio galaxy 3C 401, obtained at 1.6 microns with the NICMOS camera in which we identify the infrared counterpart of the brightest region of the radio jet. The jet has a complex radio structure and brightens where bending occurs, most likely as a result of relativistic beaming. We analyze archival data in the radio, optical and X-ray bands and we derive its spectral energy distribution. Differently from all of the previously known optical extragalactic jets, the jet in 3C401 is not detected in the X-rays even in a long 48ksec X-ray Chandra exposure and the infrared emission dominates the overall SED. We propose that the dominant radiation mechanism of this jet is synchrotron. The low X-ray emission is then caused by two different effects: i) the lack of any strong external photon field and ii) the shape of the electron distribution. This affects the location of the synchrotron peak in the ...

2005-01-01

307

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained ...

2001-04-01

308

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid ...

2001-04-01

309

Pet's research at the SHFJ, Cea, one example: development and validation of a radioligand for the study of the cerebral dopaminergic system; La recherche en TEP au SHFJ, CEA. Un exemple: developpement et validation de radioligands pour l'etude du systeme dopaminergique  

Energy Technology Data Exchange (ETDEWEB)

The aim of this work is the evaluation of biodistribution and radiation dosimetry of a cocaine analog, the N-(3-iodo-prop-2E-enyl)-2beta-carbo-methoxy-3beta-(4-methyl-phenyl) nor-tropane (PE2I), labeled with carbon 11 ([{sup 11}C]PE2I). The [{sup 11}C]PE2I is a selective radioligand for imaging neuronal dopamine transporter (DAT) with positron emission tomography (PET). The DAT is a membrane-bound pre synaptically located protein that regulates the concentration of dopamine at nerve terminals. DAT radioligands are often used to evaluate the progression of Parkinson's disease or the efficiency of neuro-protective therapeutics and, typically, these studies required several successive PET scans. (author)

2005-10-15

310

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the package is based on a ...

1999-07-01

311

Observing Evolution in the Supergranular Length Scale During Periods of Low Solar Activity  

CERN Document Server

We present the initial results of an observational study into the variation of the dominant length-scale of quiet solar emission: supergranulation. This length-scale reflects the radiative energy in the plasma of the upper solar chromosphere and transition region at the magnetic network boundaries forming as a result of the relentless interaction of magnetic fields and convective motions of the Sun's interior. We demonstrate that a net difference of ~0.5Mm in the supergranular emission length-scale occurs when comparing observations cycle 22/23 and cycle 23/24 minima. This variation in scale is reproduced in the datasets of multiple space- and ground-based instruments and using different diagnostic measures. By means of extension, we consider the variation of the supergranular length-scale over multiple solar minima by analyzing a subset of the Mt Wilson Solar Observatory (MWO) Ca II K image record. The observations and analysis presented ...

2011-01-01

312

High resolution Computed Tomography in the study of temporal bone trauma  

International Nuclear Information System (INIS)

Thirty-five patients with temporal bone fractures were examined; the fractures were sometimes associated with dislocation of the assicular chain caused by road fatalities. Computed Tomography (CT) was performed either because of the presence of clinical symptoms associated with trauma of the temporal bone, because of a hemotympanum discovered during a CT scan of the brain. Thirty-three fractures were detected: 19 longitudinal, 6 transverse, and 8 complex. An incudostapedial dislocation was also detected, together with a displacement of a stapedial prosthesis from the lenticular process of incus, and 3 incus-malleus dislocation associated with fractures. High resolution CT allows the precise definition of the course of the fractures, of the associated dislocation of the ossicular chain, and of facial nerve lesion, thus allowing a more accurate surgical intervention. In the examination of the temporal bone, high resolution CT is preferible to pluridirectional tomography because it is ...

1988-01-01

313

Free-electron laser beam  

International Nuclear Information System (INIS)

The principle and history of free-electron laser (FEL), first evidenced in 1977, the relationship between FEL wavelength and output power, the high-power FEL driven by the superconducting linac, the X-ray FEL by the linac, and the medical use are described. FEL is the vacuum oscillator tube and essentially composed from the high-energy linac, undulator and light-resonator. It utilizes free electrons in the vacuum to generate the beam with wavelength ranging from microwave to gamma ray. The first high-power FEL developed in Japanese Atomic Energy Research Institute (JAERI) is based on the development of superconducting linac for oscillating the highest power beam. In the medical field, applications to excise brain tumors (in US) and to reconstruct experimentally blood vessels in the pig heart (in Gunma University) by lasing and laser coagulator are in progress with examinations to remove intra-vascular cholesterol mass by irradiation of 5.7#mu#m FEL beam. Cancer cells are considered ...

2003-06-01

314

Dose reduction during fluoroscopic placement of feeding tubes  

Energy Technology Data Exchange (ETDEWEB)

By both increasing the optical iris of the video camera and removing the grid in fluoroscopic procedures involved in placement of a Dubbhoff feeding tube, the radiation dose to patients and staff was reduced by five to seven times. An average expected dose to a patient of about 300 mGy per procedure was reduced by two to three times when the grid was removed and by an additional three times when an iris of increased diameter was used. Because Dobbhoff procedures do not involve obtaining a diagnosis, the image degradation was acceptable and did not affect the total exposure times or ability to conduct the procedure. With the grid out, the difference between the mean exposure times of 5.1 minutes in 96 patient studies done with a normal iris opening and 4.0 minutes in 52 studies done with an enlarged iris was not statistically significant. The importance of reducing patient dose is reinforced by the finding that one-third of the patients ...

1991-03-01

315

Digital luminescent radiography: A substitute for conventional chest radiography?  

International Nuclear Information System (INIS)

The image quality of digital luminescent radiography (DLR) is sufficient for routine biplane chest radiography and for follow-up studies of heart size, pulmonary congestion, coin lesions, infiltrations, atelectasis, pleural effusions, and mediastinal and hilar lymph node enlargement. Chest radiography in the intensive care unit may in most cases be performed using the DLR technique. there is no need for repeat shots because of incorrect exposure, and the position of catheters, tubes, pacemakers, drains and artificial heart valves, the mediastinum, and the retrocardiac areas of the left lung are more confidently assessed on the edge-enhanced DLR films than on conventional films. Nevertheless, DLR is somewhat inferior to conventional film-screen radiography of the chest as it can demonstrate or rule out subtle pulmonary interstitial disease less confidently. There is no reduction of radiation exposure of the chest in DLR compared with modern ...

316

Correction for loss of track density due to overlapping track on SSNTD  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) record radiation in the form of tracks. In the case of high track density, however, it is not always possible to distinguish each track separately. The track density might then be underestimated unless the loss of track number due to overlapping is compensated. An elaborated 'erosion' or curve fitting process is applied usually, for the separation of the overlapping tracks, to automatic track counting systems. This paper shows a much simpler correction method which was developed by the analogy of the correction equation for the dead time of GM counters. From a set of about 10 data obtained from high track density detectors, the equation for SSNTD can be determined by a least square fitting. Once the equation is found, true track density could be derived easily without any help of complex image processing or calculation, such as the erosion or curve fitting. This method also provides ...

1990-06-01

317

Computed Tomography in staging and follow-up of thoracic Hodgkin's diseases  

International Nuclear Information System (INIS)

As yet, the role of Computed Tomography (CT) as a routine imaging technique in the staging and follow-up of thoracic Hodgkin's disease has not been assessed. The authors reported the results obtained in 120 patients affected with thoracic Hodgkin's disease, staged and followed by means af chest X-rays and CT. CT better identified intrathoracic involvement of mediastinal nodes, of lung parenchyma, of pleura, and of pericarcial and chest walls in 54/120 patients (45%), with staging modifications in 18 (15%) of them only. Treatment was changed only in 12 patients (19%) where radiation therapy had been planned. The clinical value of the additional information yielded by CT was especially evident in the follow-up: CT allowed the correct evaluation of persistent/ recurrent disease in 51/117 patients (43.5%), a figure high enough to suggest the use of CT in the routive follow-up of patients affected with thoracic Hodgkin's disease.

1990-01-01

318

Atmospheric scintillations and laser safety  

Science.gov (United States)

Laser devices are currently in widespread use in particular by armed forces for different tasks. Electro-optical sensors as well as unprotected human eyes are extremely sensitive to laser radiation and can be permanently damaged from direct or reflected beams. Laser damage depends on the interaction between the laser beam and the atmosphere in which it traverses. The atmospheric conditions, including the range, terrain features, turbulence, and atmospheric particulates, may alter the laser's effect on different electro-optical devices and systems. When a laser beam passes through the atmosphere the optical turbulence affects the beam. As a result, temporal intensity fluctuations (scintillations) or spatial variations in intensity within a beam cross-section occur. Atmospheric scintillations pose a safety problem because an observer or sensor can be subjected to the risk of a localized irradiance (local focusing effect) much greater than that which would occur in a ...

2011-09-01

319

A new measurement of the antiproton-to-proton flux ratio up to 100 GeV in the cosmic radiation  

CERN Document Server

A new measurement of the cosmic ray antiproton-to-proton flux ratio between 1 and 100 GeV is presented. The results were obtained with the PAMELA experiment, which was launched into low-earth orbit on-board the Resurs-DK1 satellite on June 15th 2006. PAMELA is equipped with a silicon-microstrip magnetic spectrometer and a silicon-tungsten imaging calorimeter and has been collecting data since July 2006. During 500 days of data collection a total of about 1000 antiprotons have been identified, including 100 above an energy of 20 GeV. The high-energy results are a ten-fold improvement in statistics with respect to all previously published data. The antiproton-to-proton flux ratio increases smoothly with energy up to about 10 GeV, in agreement with previous experiments, and then levels off. The data follow the trend expected from secondary production calculations and significantly constrain contributions from exotic sources, e.g. dark matter particle annihilations.

2008-01-01

320

Magnetic resonance imaging. Handbook and atlas; Kernspintomographie. Kompendium und Atlas  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging (MRI) as a diagnostic imaging tool relies on the generation of magnetic fields, whereas the computerized tomography (CT) uses X-radiation. The fundamental principle of MRI is the magnetic resonance of paramagnetic atomic nuclei. These nuclei, as e.g. protons (= hydrogen nuclei), are aligned in required orientation by application of a strong magnetic field. Upon simultaneous application of an electromagnetic high-frequency field perpendicular to the axis of the basic magnetic field, and in response to periodical changing of the electromagnetic field at a given frequency, the originally aligned paramagnetic nuclei are forced into a movement similar to that of a ``whipping top``. When the resonance frequency is shut off, the nuclei return to their former, aligned positions, inducing a weak signal in a coil. The series of signals generated by multiple repetition of this process of excitation of nuclei ...

1999-10-01

321

Using focused ion beam damage patterns to photoelectrochemically etch features in III-V materials  

Energy Technology Data Exchange (ETDEWEB)

A method of patterning n-type GaAs, InP, InGaAs, and InGaAsP by photoelectrochemical (PEC) etching in conjunction with a submicron focused ion beam (FIB) at low dose is described. The ion beam is used to produce damage in a desired pattern in the material. Subsequent PEC etching of the material reveals the ion induced features in relief. The procedure is highly sensitive, requiring a dose of only 5 x 10/sup 9/ ions/cm/sup 2/ for the differential etch to become apparent. The sensitivity allows rapid pattern generation in our FIB system.

1986-03-10

322

State-of-the-art in photovoltaic research and application (except for use in concentrators)  

Energy Technology Data Exchange (ETDEWEB)

A review is given of the state-of-the-art of single and polycrystalline solar cells, which includes a short theoretical review, laboratory achievements, and production methods. The Si single and polycrystalline cell and the amorphous Si cell are described, including material preparation, crystal and sheet growth, and cell and panel production. Promising second generation thin film solar cells including GaAs, CdS(CuInSe/sub 2/), and CdTe are briefly described. Economical aspects are discussed.

1987-01-01

323

Microcomputers: usage, methods and structures  

International Nuclear Information System (INIS)

The use of workstations, controllers or embedded systems and their applications have become much more relevant than previously. PC-based systems, a cooker programmer, applications of, for example, Prolog machines, Unix and Ada papers, Robotics and Automation are typical examples of this. The three keynote addresses of this symposium have as their subjects the most spectacular microcomputer fields and are presented by leading experts. The papers presented cover most of the traditional interests of Euromicro. Special emphasis is given to contributions on the use of workstations and personal computers, on RISC and GaAs and on transputers.

324

Local Heine-Abarenkov model potential for III-V and II-VI covalent compounds  

Energy Technology Data Exchange (ETDEWEB)

A local Heine-Abarenkov model potential is proposed for zinc blende-type crystals. The potential parameters are determined by satisfying the zero pressure condition and the first zero of the empirical pseudopotential interpolated from band calculations. Two sets of parameters are presented for thirteen tetrahedral compounds such as AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, InSb, ZnS, ZnSe, ZnTe, and CdTe.

1983-10-01

325

Primary malignant lymphoma of the brain; Primaere maligne Lymphome des Gehirns  

Energy Technology Data Exchange (ETDEWEB)

Primary malignant lymphoma of the brain is a disease of unknown etiology, which is increasing in incidence and has an unfavorable prognosis. Despite the lack of specific changes on CT or MRI in most cases, these procedures may typically facilitate the diagnosis: A focal-enhancing mass with subependymal spread on CT or MRI and hyperattenuation on nonenhanced CT are the most reliable features in the diagnosis of primary malignant lymphoma of the brain. Peritumoral edema and mass effect are usually not prominent features. On unenhanced CT scans they usually appear homogeneously isodense to mildly hyperdense relative to the gray matter. On MRI these tumors are slightly hypointense on T1-weighted images and slightly hpyerintense on PD- and T2-weighted images relative to the gray matter. On CT and MRI enhancement is usually homogeneous. Contrast-enhanced MRI, with its multiplanar capability, lack of bone-induced artifacts, and high-contrast ...

1997-01-01

326

Transmission electron microscopy of strained In/sub y/Ga/sub 1//sub -//sub y/As/GaAs multiquantum wells: The generation of misfit dislocations  

Energy Technology Data Exchange (ETDEWEB)

We have investigated the generation and propagation of misfit dislocations in strained In/sub y/Ga/sub 1-//sub y/As/GaAs multiquantum wells grown by molecular-beam epitaxy, with cross-sectional transmission electron microscopy. The samples are of excellent optical quality, with multiquantum wells having well widths of 100 A, being characterized by excitonic linewidths and Stokes shifts of 1.5--2.5 and 1--2 meV, respectively. We have examined the growth of 2-..mu..m-thick multiquantum-well samples grown either directly on GaAs, or with an intermediate composition buffer layer, and for the cases of small (y = 0.07) and large (y = 0.16) misfits. It is seen that for the case of quantum wells with small misfit, grown directly on GaAs, metastable growth can be achieved. This is confirmed by low-temperature absorption measurements and from transmission electron microscopy experiments performed both before and after post-growth thermal annealing. In ...

1989-05-01

327

Temperature dependence of the performance of ultraviolet detectors  

Energy Technology Data Exchange (ETDEWEB)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric ...

2003-08-21

328

Temperature dependence of the performance of ultraviolet detectors  

International Nuclear Information System (INIS)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile of the conduction band and the valence band edges. In the presence of an electric ...

2003-08-21

329

Optical second-harmonic generation in III-V semiconductors: Detailed formulation and computational results  

Science.gov (United States)

In an earlier paper (Phys. Rev. Lett. 66, 41 (1991)), we calculated both the dielectric constant ({epsilon}{sub {infinity}}) and the nonlinear optical susceptibilities for second-harmonic generation ({chi}{sup (2)}) in the static limit for AlP, AlAs, GaP, and GaAs in the local-density approximation with and without a self-energy correction in the form of a scissors operator,'' including local-field effects. In this paper, we expand our presentation of this calculation. Agreement with experiment to within 15% for the nonlinear susceptibility is demonstrated where experiments are available (GaP and GaAs); the dielectric constants are in no worse than 4% agreement with experiment. The virtual hole'' contributions are reformulated to avoid large numerical cancellations in the case of near degeneracies. The virtual electron'' terms dominate over the virtual hole'' terms ...

1991-12-15

330

New materials for future generations of III-V solar cells  

Energy Technology Data Exchange (ETDEWEB)

Three- and four-junction III-V devices are proposed for ultrahigh-efficiency solar cells using a new 1-eV material lattice-matched to GaAs, namely, GaInNAs. We demonstrate working prototypes of a GaInNAs-based solar cell lattice-matched to GaAs with photoresponse down to 1 eV. Under the AM1.5 direct spectrum with all the light higher in energy than the GaAs band gap filtered out, the prototypes grown with base doping of about 10{sup 17}&hthinsp;cm{sup {minus}3} have open-circuit voltages ranging from 0.35 to 0.44 V, short-circuit current densities of 1.8 mA/cm{sup 2}, and fill factors from 61{percent} to 66{percent}. To improve on the current record-efficiency tandem GaInP/GaAs solar cell by adding a GaInNAs junction, the short-circuit current density of this 1-eV cell must be significantly increased. Because these low short-circuit current densities are due to short diffusion lengths, we have demonstrated a ...

1999-03-01

331

Investigation of ultrafast photothermal surface expansion and diffusivity in GaAs via laser-induced dynamic gratings  

Energy Technology Data Exchange (ETDEWEB)

This thesis details the first direct ultrafast measurements of the dynamic thermal expansion of a surface and the temperature dependent surface thermal diffusivity using a two-color reflection transient grating technique. Studies were performed on p-type, n-type, and undoped GaAs(100) samples over a wide range of temperatures. By utilizing a 90 fs ultraviolet probe with visible excitation beams, the effects of interband saturation and carrier dynamics become negligible; thus lattice expansion due to heating and subsequent contraction caused by cooling provided the dominant influence on the probe. At room temperature a rise due to thermal expansion was observed, corresponding to a maximum net displacement of {approximately} 1 {Angstrom} at 32 ps. The diffracted signal was composed of two components, thermal expansion of the surface and heat flow away from the surface, thus allowing a determination of the rate of expansion as well as the surface thermal diffusivity, ...

1992-04-01

332

Visibility of tumor-like details in inline phase contrast mammography using quasimonochromatic X-ray sources  

Energy Technology Data Exchange (ETDEWEB)

A new generation of quasimonochromatic high-flux X-ray sources, based on the X-ray radiation produced through Compton scattering between an electron beam and a laser beam, is under development. One of the possible applications of this source is inline phase contrast mammography, based on the observation of the edge-enhancement effect that can be observed at the border of structures inside the breast in images produced using a partially or totally coherent X-ray beam. In this work we present the results of a set of simulations of inline phase contrast mammography using typical inverse Compton scattering sources parameters. The simulated sample was a tumour-like mass having spherical shape, diameter between 200 {mu}m and 5 mm, placed inside a breast-like matrix, 4 cm thick, and a standard composition of 50% glandular tissue and 50% adipose tissue. We discuss the minimum requirements for mammography using inverse Compton scattering sources and we ...

2009-09-01

333

Synthesis and PET imaging of the benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil  

International Nuclear Information System (INIS)

The central benzodiazepine receptor tracer [N-methyl-"1"1C]iomazenil (Ro 16-0154) was synthesized by alkylation of the desmethyl precursor noriomazenil with ["1"1C]methyl iodide. The ["1"1C]CH_3I (prepared by reduction of ["1"1C]CO_2 with LiAlH_4 followed by reaction with HI) was reacted with noriomazenil inN,N -dimethylformamide and Bu_4N"+OH"- for 1 min at 80 deg. C and purified by HPLC (C_1_8, 34% CH_3CN/H_2O, 7 mL/min). The product was obtained with synthesis time 35 #+-# 5 min (mean #+-# SD, n = 7), radiochemical yield (EOB) 36 #+-# 16%, radiochemical purity 99 #+-# 1%, and specific activity 5100 #+-# 2800 mCi/#mu#mol. Absorbed radiation doses were calculated from previously acquired human biodistribution data. The urinary bladder wall received the highest dose (0.099 mGy/MBq) for 4.8 h voiding interval and the effective dose equivalent was 0.015 mSv/MBq. After i.v. injection of ["1"1C]iomazenil in an adult baboon or healthy human volunteer, radioactivity ...

1995-07-01

334

Results of the remote sensing feasibility study for the uranium hexafluoride storage cylinder yard program  

Energy Technology Data Exchange (ETDEWEB)

The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to $1,500K per annum just ...

1997-02-01

335

Functional magnetic resonance imaging of the normal and abnormal visual system in early life.  

DEFF Research Database (Denmark)

Functional magnetic resonance imaging (fMRI) in young children may provide information about the development of the visual cortex, and may have predictive value for later visual performance. The purpose of this study was to evaluate the usefulness of fMRI for examining cerebral processing of vision in very young infants and in infants with brain damage. We examined 15 preterm infants, 12 children suspected of having a cerebral visual impairment and 10 children with a normal visual system, all of whom were either spontaneously asleep or sedated with chloral hydrate. Cortical response to stroboscopic light stimulation could be demonstrated in all technically acceptable data sets from children with a post-menstrual age (PMA) of > 41 weeks, but not in younger infants. Children < 60 weeks PMA showed either a blood oxygenation level-dependent (BOLD) signal increase or decrease, while all older children showed a signal decrease. The activated cortical volumes showed ...

2000-01-01

336

Dose verification using a pelvic phantom in high dose rate (HDR) brachytherapy  

Energy Technology Data Exchange (ETDEWEB)

High dose rate (HDR) brachytherapy for treating a cervix carcinoma has become popular, because it eliminates many of the problems associated with conventional brachytherapy. In order to improve the clinical effectiveness with HDR brachytherapy, a dose calculation algorithm, optimization procedures, and image registrations need to be verified by comparing the dose distributions from a planning computer and those from a humanoid phantom. In this study, the humanoid phantom was fabricated in order to verify the absolute doses and the relative dose distributions. The measured doses from the humanoid phantom were then compared with the treatment planning system for the dose verification. The humanoid phantom needs to be designed such that the dose distributions can be quantitatively evaluated thermoluminescent dosimeter (TLD) chips with a dimension of 1/8 and film dosimetry with a spatial resolution of <1 mm used to measure the radiation ...

2003-07-01

337

Disorders of brain development and phakomatosis  

International Nuclear Information System (INIS)

Full text: Disorders of brain development and phakomatosis are resulting from disturbed embryonic-foetal development One third of all major embryological anomalies involve CNS, and over 2000 different anomalies have been described. Anomalies of the brain often cause foetal and neonatal death, and mental and physical retardation in pediatric group. The majority of disorders of brain development and phakomatosis are idiopathic, and most of them are not hereditary or familial. Ultrasonography plays the important role in screening foetal and neonatal brain, but after closure of fontanels it is difficult to find the acoustic window. CT has limited contrast resolution, and disadvantage exposing infant to ionizing radiation. It is helpful to demonstrate the presence of calcifications. MR imaging has proved to be a diagnostic tool of major importance in children with disorders of brain development and phakomatosis. The excellent grey/white matter ...

338

A revised dosimetric model of the adult head and brain  

Energy Technology Data Exchange (ETDEWEB)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head ...

1996-06-01

339

A revised dosimetric model of the adult head and brain  

International Nuclear Information System (INIS)

During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head ...

1996-07-21

340

Primary Ewing's sarcoma of the vertebral column  

International Nuclear Information System (INIS)

To determine the demographics, imaging findings, clinical symptoms, and prognosis of primary vertebral Ewing's sarcoma (PVES). A retrospective review of medical records and radiological studies of patients diagnosed with PVES from 1936 through 2001 in our institution and Department of Pathology consultation files was undertaken. Metastatic and soft tissue Ewing's sarcoma cases were excluded. From a total of 1,277 cases of Ewing's sarcoma, 125 (9.8%) had a primary vertebral origin. There were 48 females and 76 males. Patient ages ranged from 4 to 54 (mean 19.3, standard deviation 10.7, median 16) years. Vertebral column distribution was four cervical (3.2%), 13 thoracic (10.5%), 31 lumbar (25%), and 67 sacrum (53.2%). More than one vertebral segment was involved in ten cases (8%). Satisfactory imaging studies were available in 51 patients: 49 radiographs, 27 computerized tomography (CT), and 23 magnetic resonance imaging ...

2004-09-01

341

Development of internal dose estimation software on radiation protection  

International Nuclear Information System (INIS)

Objective: To develop a computerized method of internal dose estimation on radiation protection. Methods: Based on MIRD mathematic model of the organs and by means of the programming language of MS Visual Basic 6.0, a computer program of dose estimation in internal radiation was developed for radiation protection. Results: The computerized method of dose estimation for internal radiation was completed. Conclusions: This computerized method is very convenient for internal radiation dose estimation of several aspects. It can also be used in radiation accident. (authors)

2008-10-01

342

Radioisotope imaging of brain tumors in two rhesus monkeys. Final report  

Energy Technology Data Exchange (ETDEWEB)

Two geriatic male rhesus monkeys were used for the radioisotope imaging in this research. Discussion of the radionuclide, materials, and method used to accomplish the neurologic examination and the results obtained, both during the procedure and confirmation of the results by necropsies were accompanied by color photos of scan images. Results were that the nuclear images provided accurate images of intracranial neoplasia.

1988-04-01

343

Impact of computers in radiography: the advent of digital radiography, part-2  

International Nuclear Information System (INIS)

Computed radiography (CR) systems use a photostimulable phosphor plate enclosed in a cassette. In CR, image acquisition is a two-stage process wherein image capture and image read out are done separately. Direct digital radiography (DR) systems, on the other hand, use detectors that have a combined image capture and image read out capability. DR systems are also called as DDR or ddR systems by some vendors. This article focuses on DR systems

2008-08-01

344

Fracture imaging with converted elastic waves  

Energy Technology Data Exchange (ETDEWEB)

This paper examines the seismic signatures of discrete, finite-length fractures, and outlines an approach for elastic, prestack reverse-time imaging of discrete fractures. The results of this study highlight the importance of incorporating fracture-generated P-S converted waves into the imaging method, and presents an alternate imaging condition that can be used in elastic reverse-time imaging when a direct wave is recorded (e.g., for crosswell and VSP acquisition geometries).

2001-05-29

345

The evaluation of risks from radiation  

International Nuclear Information System (INIS)

German translation of the publication 'The evaluation of risks from radiation' published in 1965 by the International Commission on Radiological Protection. In a survey, genetic and somatic risks from radiation are presented and explained. (HP).

1977-01-01

347

Role of Mast Cells in Early and Delayed Radiation Injury in Rat Intestine  

Science.gov (United States)

... mast cell staining; ref. 16). The severity of structural radiation injury was assessed using a histopathological radiation injury score ... ...

348

Radionuclide X-ray fluorescence analysis. 1: Excitation of X-ray fluorescense radiation by nuclear radiation  

Science.gov (United States)

The principles of radionuclide excitation of X-ray fluorescence radiation and its application in

1972-01-01

349

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

350

Radiation protection - an overview of the concept for radiation protection at work and the concept for environmental radiation protection  

International Nuclear Information System (INIS)

This book gives an overview of the entire field of radiation protection with the subject areas radioactivity, X-rays, UV radiation, laser beams and high-frequency electromagnetic fields. It deals graphically with the most important physical notions, the incidence, origin, properties and biological effects of types of radiation, administrative and practical protection measures and the code of rules governing them. Apart from fundamentals of radiation protection the emphasis on the following: natural radiation exposure, radiation exposure to radon, disaster relief plans in the environment of nuclear plant, the precautionary radiation protection system evolved after Chernobyl, radiation exposure through UV radiation devices, radio, RF communication, radar, microwave ovens and high-voltage transmission ...

1993-01-01

351

Repeat Stereotactic Radiosurgery for Acoustic Neuromas  

International Nuclear Information System (INIS)

Purpose: To evaluate the outcome of repeat stereotactic radiosurgery (SRS) for acoustic neuromas, we assessed tumor control, clinical outcomes, and the risk of adverse radiation effects in patients whose tumors progressed after initial management. Methods and Materials: During a 21-year experience at our center, 1,352 patients underwent SRS as management for their acoustic neuromas. We retrospectively identified 6 patients who underwent SRS twice for the same tumor. The median patient age was 47 years (range, 35-71 years). All patients had imaging evidence of tumor progression despite initial SRS. One patient also had incomplete surgical resection after initial SRS. All patients were deaf at the time of the second SRS. The median radiosurgery target volume at the time of the initial SRS was 0.5 cc and was 2.1 cc at the time of the second SRS. The median margin dose at the time of the initial SRS was 13 Gy and was 11 Gy at the time of the second ...

2010-02-01

352

In situ texture analysis under applied load  

International Nuclear Information System (INIS)

The in-situ measurement of a crystallographic texture is a special type of a non-destructive measurement, which need special equipments. Due to the high photon flux and the excellent brilliance high energetic synchrotron radiations are a fantastic tool particular in fast experimentation. Moreover, a high penetration power allows the investigation of standard tensile sample of the DIN-norm. A loading device with a power up to 20 kN was installed at the hard wiggler beamline BW5 (HASYLAB-DESY) to perform in-situ strain and in-situ texture analysis. Using 100keV X-rays one gets short wavelength so that a 2D image-plate detector offers a wide range of diffraction pattern within the first 10 degree in 2 theta. Thermal neutron is another radiation with a high penetration power, which is the standard method for global texture analysis of bulk samples. As an example rectangular extruded Mg- Az31 was investigated by an in-situ. ...

353

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined thickness of the six beryllium windows needed in a Dewar-type enclosure and showed that a single window ...

354

Real-time neutron coded aperture imaging: A technique for nondestructive three-dimensional imaging  

Energy Technology Data Exchange (ETDEWEB)

Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of ...

1992-01-01

355

Clinical implementation of a convolution based algorithm for 3D treatment planning  

International Nuclear Information System (INIS)

Purpose/Objective: With the advent of computed tomography and magnetic resonance imaging, the three dimensional representation of the patient anatomy has become an invaluable resource for better diagnosis and delineation of the target volume and sensitive structures in radiation therapy. Although the therapeutic linear accelerator industry has made available highly sophisticated equipment, the aggressiveness in dose prescription and delivery has to be complimented by accurate dose computation methods. We have adopted a convolution/superposition algorithm for the calculation of absolute dose that fully accounts for the external shape and internal structure of the patient for photon treatment radiotherapy. In this paper, we will discuss the principles of the convolution algorithm and we will show how the computed dose compares to clinically relevant treatment techniques. Materials and Methods: A computer controlled data acquisition system and a ...

356

The Possibility of Digital Imaging in the Diagnosis of Occlusal Caries  

UK PubMed Central (United Kingdom)

The aim of this study was to assess the possibility of digital image analysis of pit-and-fissure discoloration in order to diagnose caries. Digital images showing pit-and-fissure discoloration in 100...Full Text Available

2010-01-01

357

Selective imaging of adherent targeted ultrasound contrast agents  

UK PubMed Central (United Kingdom)

The goal of ultrasonic molecular imaging is the detection of targeted contrast agents bound to receptors on endothelial cells. We propose imaging methods that can distinguish adherent microbubbles...Full Text Available

2007-04-21

358

Radionuclide imaging of the acutely painful scrotum  

International Nuclear Information System (INIS)

This paper discusses the clinical application and main objective of testicular imaging. The authors present cases that represent a spectrum of the abnormalities which might be detected by testicular imaging, with special attention given to testicular torsion and the acute diseases which may mimic it clinically. Accuracy of the test is noted.

359

Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm  

UK PubMed Central (United Kingdom)

Four-dimensional (4D) radiotherapy is the explicit inclusion of the temporal changes in anatomy during the imaging, planning, and delivery of radiotherapy. One key component of 4D radiotherapy planning...Full Text Available

2008-04-01

360

Performance evaluation of an automatic anatomy segmentation algorithm on repeat or four-dimensional CT images using a deformable image registration method  

UK PubMed Central (United Kingdom)

PurposeAuto-propagation of anatomical region-of-interests (ROIs) from the planning CT to daily CT is an essential step in image-guided adaptive radiotherapy. The...Full Text Available

2008-09-01

361

Nonnegative Factorization of Diffusion Tensor Images and Its Applications  

UK PubMed Central (United Kingdom)

This paper proposes a novel method for computing linear basis images from tensor-valued image data. As a generalization of the nonnegative matrix factorization, the proposed method aims to approximate...Full Text Available

2011-01-01

362

Near Infrared-Fluorescent and Magnetic Resonance Imaging Molecular Probe with High T1 Relaxivity for In Vivo Multimodal Imaging  

UK PubMed Central (United Kingdom)

A new gadolinium chelating NIR fluorescent molecular probe increases T1 relaxivity of water protons, facilitating combined optical and magnetic resonance imaging.

2010-06-07

363

MULTIMODALITY IMAGING: BEYOND PET/CT AND SPECT/CT  

UK PubMed Central (United Kingdom)

Multimodality imaging with PET/CT and SPECT/CT has become commonplace in clinical practice and in preclinical and basic medical research. Do other combinations of imaging modalities have a similar...Full Text Available

2009-09-01

364

Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging  

UK PubMed Central (United Kingdom)

Purpose: Small animal micro-CT imaging is being used increasingly in preclinical biomedical research to provide phenotypic descriptions of genomic models. Most of this imaging is coincident...Full Text Available

2010-09-01

365

Imaging of calcium transients in skeletal muscle fibers.  

UK PubMed Central (United Kingdom)

Epifluorescence images of Ca2+ transients elicited by electrical stimulation of single skeletal muscle fibers were studied with fast imaging techniques that take advantage of the large fluorescence...Full Text Available

1991-01-01

366

High speed optical coherence microscopy with autofocus adjustment and a miniaturized endoscopic imaging probe  

UK PubMed Central (United Kingdom)

Optical coherence microscopy (OCM) is a promising technique or high resolution cellular imaging in human tissues. An OCM system for high-speed en face cellular resolution imaging...Full Text Available

2010-03-01

367

Diagnostic radiology: An Anglo-American textbook of imaging  

Energy Technology Data Exchange (ETDEWEB)

This multiauthored text is aimed particularly toward the resident or registrar training in diagnostic radiology. This is a text book on the entire scope of diagnostic imaging. It includes techniques and imaging modalities of all the systems, head, face and neck. The book covers the entire gamut of diagnostic radiology.

1986-01-01

368

Diagnostic quality of low resolution images for tele-woundcare.  

UK PubMed Central (United Kingdom)

The use of digital wound images would allow remote consultation between patients, physicians, or other caregivers over the Internet. To evaluate the efficacy and validity of digital images for assessment...Full Text Available

1998-01-01

369

Comprehensive Quantification of Signal-to-Noise Ratio and g-Factor for Image-Based and k-Space-Based Parallel Imaging Reconstructions  

UK PubMed Central (United Kingdom)

Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final...Full Text Available

2008-10-01

370

Comparative evaluation of similarity measures for the rigid registration of multi-modal head images  

Energy Technology Data Exchange (ETDEWEB)

Image registrations that are based on similarity measures simply adjust the parameters of an appropriate spatial transformation model until the similarity measure reaches an optimum. The numerous similarity measures that have been proposed in the past are differently sensitive to imaging modality, image content and differences in the image content, selection of the floating and target image, partial image overlap, etc. In this paper, we evaluate and compare 12 similarity measures for the rigid registration. To study the impact of different imaging modalities on the behavior of similarity measures, we have used 16 CT/MR and 6 PET/MR image pairs with known 'gold standard' registrations. The results for the PET/MR registration and for the registration of CT to both rectified and unrectified MR ...

2007-09-21

371

Compact Image Slicing Spectrometer (ISS) for hyperspectral fluorescence microscopy  

UK PubMed Central (United Kingdom)

An image slicing spectrometer (ISS) for microscopy applications is presented. Its principle is based on the redirecting of image zones by specially organized thin mirrors within a custom fabricated...Full Text Available

2009-07-20

372

An Evaluation of a Computer Imaging Program to Prepare Women for Chemotherapy-related Alopecia  

UK PubMed Central (United Kingdom)

ObjectiveThis study was conducted to evaluate a computer-imaging program called HAAIR (Help with Adjustment to Alopecia by Image Recovery) that was developed to provide...Full Text Available

2010-07-01

373

Post-mortem fetal MRI: What do we learn from it?  

International Nuclear Information System (INIS)

Post-mortem magnetic resonance (MR) imaging is of increasing interest not only as an alternative to autopsy but as a research tool to aid the interpretation and diagnosis of in utero MR images. The information from the post-mortem MR has allowed the development of imaging sequences applicable to in utero imaging and neonatal imaging. It has established brain development during gestation and has provided data on this to which in utero MR can be compared. The detail available from the post-mortem images is such that brain development can be studied in a non-invasive manner, a permanent record on the normal and abnormal areas is available and a greater understanding of developmental abnormalities is possible.

2006-02-01

374

MR imaging in neuroborreliosis of the cervical spinal cord  

Energy Technology Data Exchange (ETDEWEB)

The central nervous system is involved in 10-20% of cases in Lyme disease. The neurological symptoms, time course of the disease and imaging findings are multifaceted. We report two patients with cervical radiculitis. Magnetic resonance imaging revealed strong enhancement of the cervical nerve roots on contrast-enhanced T1-weighted images. These imaging patterns of borrelia-associated radiculitis have not been reported before. Knowledge of these imaging features may help to diagnose neuroborreliosis, which presents with non-specific symptoms. (orig.)

2004-11-01

377

THE ENVIRONMENTAL MANAGEMENT AND CO-ORDINATION ACT, 1999  

Wastenet

Subject to the provisions of the Radiation Protection Act, the Authority, on the advice of ...(f) in collaboration with the Radiation Protection Board, conduct an ionising radiation monitoring programme and ...or document kept under the control of the Radiation Protection Board.

385

Application of gamma radiation  

International Nuclear Information System (INIS)

Described and discussed in this paper are radiation processes and their advantages over the conventional techniques. Radiation sterilization of medical products, food irradiation, wood plastic composites, and radiation treatment of sewage and waste waters are presented. The Philippine experience in using these technologies, its problems and barriers are also given. (ELC).

1985-12-10

388

Typhoon Aere : Image of the Day - NASA Earth Observatory  

Science.gov (United States)

Aug 25, 2004 ... The Tropical Rainfall Measuring Mission or TRMM satellite provided this image of Typhoon Aere over the western Philippine Sea as it was ...

389

Portal localization images using computed radiography for high-energy electron beam therapy  

Energy Technology Data Exchange (ETDEWEB)

Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)

2002-09-01

390

Method for the reduction of image content redundancy in large image databases  

Energy Technology Data Exchange (ETDEWEB)

A method of increasing information content for content-based image retrieval (CBIR) systems includes the steps of providing a CBIR database, the database having an index for a plurality of stored digital images using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the images. A visual similarity parameter value is calculated based on a degree of visual similarity between features vectors of an incoming image being considered for entry into the database and feature vectors associated with a most similar of the stored images. Based on said visual similarity parameter value it is determined whether to store or how long to store the feature vectors associated with the incoming image in the database.

2010-03-02

391

JHK and 3.3um PAH Imaging of the Starburst Ring in the Type I Seyfert Galaxy NGC 7469  

Science.gov (United States)

Imaging of NGC 7469 in the J, H, & K bands shows that the starburst 'ring' is a tight inner

1993-01-01

392

Imaging subsurface using cross-correlation  

Energy Technology Data Exchange (ETDEWEB)

This paper presents two imaging methods by using cross correlation. The one method images the subsurface by cross-correlation of the observed data and partial derivative seismograms calculated for a guessed model. The other method images the interface by use of cross-correlation of the virtual sources and the back propagated wave fields calculated from the observed data. Experimental tests show that both methods image subsurface interfaces well even if the guessed model is different from the true one. These imaging methods are reverse time migration that we perform cross-correlation as an imaging condition and have an advantage, as compared to conventional waveform inversion method, that images subsurface structure without iterative perturbation of the assumed model. (author). 18 refs., 15 figs.

1997-12-31

393

Image Analysis and Computer Vision: 1996.  

Science.gov (United States)

... Title : Image Analysis and Computer Vision: 1996. ... bibliography,. Corporate Author : MARYLAND UNIV COLLEGE PARK COMPUTER VISION LAB. ...

1997-01-01

394

Histopathological Image Analysis: A Review  

UK PubMed Central (United Kingdom)

Over the past decade, dramatic increases in computational power and improvement in image analysis algorithms have allowed the development of powerful computer-assisted analytical approaches...Full Text Available

2009-01-01

396

Radiobiology  

International Nuclear Information System (INIS)

This text-book (electronic book - multi-media CD-ROM) constitutes a course-book - author's collection of lectures. It consists of 13 lectures in which the reader acquaints with the basis of radiobiology: Introduction to radiobiology; Physical fundamentals of radiobiology; Radiation of cells; Modification of radiation damage of cells; Reparation of radiation damage of cells; Radiation syndromes and their modification; Radiation injury; Radiation damage of tissues; Effect of radiation on embryo and fetus; Biological effects of incorporated radionuclides; Therapy of acute irradiation sickness; Delayed consequences of irradiation; Radiation oncology and radiotherapy. This course-book may be interesting for students, post-graduate students of chemistry, biology, physics, medicine as well as for teachers, scientific workers ...

397

Radiation Therapy in Treating Patients With Prostate Cancer  

Science.gov (United States)

Prostate Cancer; Psychosocial Effects of Cancer and Its Treatment; Radiation Toxicity; Sexual Dysfunction and Infertility

2011-09-13

399

NAME=\\  

Wastenet

... Radiation Protection Products and Equipment Find and compare a variety of radiation protection products and equipment on the world's largest environmental industry portal. View product ...

401

Standards and guidances for limiting ionizing radiation exposure  

Energy Technology Data Exchange (ETDEWEB)

This chapter is concerned with standards and guidances for limiting radiation exposures. It is divided into three sections, each of which has several parts. Section 1: Ionizing Radiation -- Standards and Guidances Applicable to the Public: Part A, Radiation Protection Standards; Part B, Environmental Radiation Standards; Part C, Exempt Levels of Radioactivity; Part D, Protective Action Guides for Accidents. Section 2: Ionizing Radiation -- Standards Applicable to the Workplace. Section 3: Medical and Other Standards.

1992-12-31

402

Radiation protection in the operating room  

International Nuclear Information System (INIS)

On the basis of legally provided area dose measurements and time records of fluoroscopic examinations during the operation, radiation doses to medical personnel and patients are evaluated. Adequate radiation protection measures and a careful behaviour in the operating room keep the radiation exposure to the personnel below the maximum permissible exposure. Taking into account the continuous personnel radiation monitoring and medical supervision, radiation hazards in the operating room can be considered low.

403

Phantom and animal imaging studies using PLS synchrotron X-rays  

CERN Document Server

Ultra-high resolution radiographs can be obtained using synchrotron X-rays. A collaboration team consisting of K-JIST, POSTECH and YUMC has recently commissioned a new beamline (5C1) at Pohang Light Source (PLS) in Korea for medical applications using phase contrast radiology. Relatively simple image acquisition systems were set up on 5C1 beamline, and imaging studies were performed for resolution test patterns, mammographic phantom, and animals. Resolution test patterns and mammographic phantom images showed much better image resolution and quality with the 5C1 imaging system than the mammography system. Both fish and mouse images with 5C1 imaging system also showed much better image resolution with great details of organs and anatomy compared to those obtained with a conventional mammography system. A simple and ...

2001-01-01

404

Combining anatomy and function: the path to true image fusion  

Energy Technology Data Exchange (ETDEWEB)

Modern imaging technologies visualize different aspects of disease in a non-invasive way. Considerable progress has been made in the fusion of images from different imaging modalities using software approaches. One goal of fusion software is to align anatomical and functional images and allow improved spatial localization of abnormalities. The resulting correlation of the anatomical and functional images may clarify the nature of the abnormality and help diagnose or stage the underlying disease. Whereas successful image fusion software has been developed for the brain, only limited success has been achieved for image alignment in other parts of the body. The development and current status of alternative approaches are presented. Dual-modality imaging is described with devices where two modalities are combined and mounted ...

2001-10-01

405

Approximate fuzzy C-means (AFCM) cluster analysis of medical magnetic resonance image (MRI) data  

International Nuclear Information System (INIS)

The authors describe the application of an approximate fuzzy C-means (AFCM) clustering algorithm as a data dimension reduction approach to medical magnetic resonance images (MRI). Image data consisted of one T1-weighted, two T2-weighted, and one T2*-weighted (magnetic susceptibility) image for each cranial study and a matrix of 10 images generated from 10 combinations of TE and TR for each body lymphoma study. All images were obtained with a 1.5 Tesla imaging system (GE Signa). Analyses were performed on over 100 MR image sets with a variety of pathologies. The cluster analysis was operated in an unsupervised mode and computational overhead was minimized by utilizing a table look-up approach without adversely affecting accuracy. Image data were first segmented into 2 coarse clusters, each of which was then subdivided ...

406

Survey of Radiation Protection Education and Training in Finland in 2003  

Energy Technology Data Exchange (ETDEWEB)

The current state and need for radiation protection training in Finland have been surveyed by the Radiation and Nuclear Safety Authority STUK. The survey sought to determine whether the current requirements for radiation protection training had been met, and to promote radiation protection training. Details of the scope and quality of present radiation protection training were requested from all educational institutes and organizations providing radiation protection training. The survey covered both basic and further training, special training of radiation safety officers, and supplementary training. The questionnaire was sent to 77 educational organization units, 66 per cent of which responded. Radiation workers and radiation safety officers were asked about radiation protection ...

2004-07-01

407

DoseWatchers - A computer based X ray dose monitoring project in paediatric radiology  

International Nuclear Information System (INIS)

Full text: Introduction. Children, especially premature infants and neonates, are at a much higher risk to obtain an X ray induced disturbance of life - particularly cancer. On the one hand this is due to their longer life expectancy and on the other hand it is due to their higher cell proliferation rate. The paediatric radiology unit of the Inselspital Bern recently installed some of the most advanced X ray equipment nowadays available. It is based on the two latest digital technologies: double read computed radiography (CR) and direct digital radiography (DR). Only the implementation of these digital radiography systems permits the digital acquisition and additionally the analysis of acquired data. The systematic analysis of large amounts of biometric data and exposition data is the basis for further dose reduction and a systematic quality control (QC). Patients are increasingly critical concerning radiation exposure - especially parents regarding their children. ...

2006-11-13

408

Visible Earth: Typhoon Aere  

Science.gov (United States)

NASA's Visible Earth catalog of NASA images and animations of our home planet.

411

Theoretical study of subwavelength imaging by acoustic metamaterial slabs  

CERN Document Server

We investigate theoretically subwavelength imaging by acoustic metamaterial slabs immersed in the liquid matrix. A near-field subwavelength image formed by evanescent waves is achieved by a designed metamaterial slab with negative mass density and positive modulus. A subwavelength real image is achieved by a designed metamaterial slab with simultaneously negative mass density and modulus. These results are expected to shed some lights on designing novel devices of acoustic metamaterials.

2009-01-01

415

Possibilities of rayleigh-taylor instability measurement by X-ray phase imaging  

International Nuclear Information System (INIS)

X-ray imaging is a very useful plasma diagnostic method. A theoretical analysis of the x-ray phase imaging in the method based on Fresnel diffraction is given. The authors show it is a linear band pass filter, a property suit for Rayleigh-Taylor (R-T) instability measurement. The evaluation permits the possibility of R-T instability measurement in x-ray phase imaging

420

MR imaging of musculoskeletal trauma to the pelvis and the lower limb  

Energy Technology Data Exchange (ETDEWEB)

Magnetic resonance imaging can be used in the trauma setting to detect fractures and associated soft tissue injuries of the musculoskeletal system. Magnetic resonance imaging complements plain radiography and CT for evaluating cancellous bone, cartilage and growth-plate injuries, and intra- and extraarticular supporting soft tissue structures. This review outlines typical applications and imaging consideration for injuries of the pelvis and lower extremity. (orig.) With 12 figs., 78 refs.

1999-03-01

422

Lead-203 for skeletal imaging  

International Nuclear Information System (INIS)

... biological variability body distribution kidneys labelled compounds lead 203

423

Knowledge-based image analysis: some aspects on the analysis of images using other types of information  

Energy Technology Data Exchange (ETDEWEB)

The computer vision approach to image analysis is discussed from two aspects. First, this approach is constrasted to the pattern recognition approach. Second, how external knowledge and information and models from other fields of science and engineering can be used for image and scene analysis is discussed. In particular, the connections between computer vision and computer graphics are pointed out.

1982-01-01

432

Fundamental study on Fuji Computed Radiography (FCR) image  

International Nuclear Information System (INIS)

Japanese (Mar 1986). Japan Tomiyoshi, Tsukasa Kakoi, Iwao Fukushima,

1986-01-01

435

Eddy current imaging  

Energy Technology Data Exchange (ETDEWEB)

Image representations have gained wide acceptance in displaying data collected during optical, ultrasonic, radiographic, and thermographic inspections. Applying imaging techniques to eddy current testing is explored in this article. The authors show that flaw interpretation and characterization are made considerably simpler when images are used to visualize the impedance changes in eddy current probes.

1993-04-01

447

A submillimeter wavelength space-based imaging radar  

Science.gov (United States)

This report considers the use of a submillimeter wavelength space-based imaging radar. The main application envisioned is midcourse decoy discrimination for strategic defense, for which it would have the capability of producing a series of images, in real time, at strategic ranges, with less than meter scale resolution and with modest power requirements. Undoubtedly, there are other applications. The requirements for a SAR and ISAR imaging radar at submillimeter wavelength are determined, and the prospect for the development of RF sources to power the radar is examined.

1988-05-01

449

Utilization of fractional Brownian motion in constrained least-squares restoration of medical images  

International Nuclear Information System (INIS)

Constrained least-squares techniques have been used to produce a well known class of image restoration algorithms. These techniques typically involve minimizing a linear operator on a vector representation of an image, subject to a constraint. For cases where an equality constraint is appropriate the method of Lagrange multipliers can be used to produce a restored image. In this work a fractal textural model, fractional Brownian motion, is used to represent images of interest. Using a variance fractal dimension estimator a non-linear operator, that represents the squared difference between the fractal dimension of the restored image and on a priori value is minimized, subject to the constraint that the norm of the residual between the restored image and available measurement equal the norm of the additive noise.

450

Document image retrieval with morphology-based segmentation and features combination  

Science.gov (United States)

Digital libraries need more than just a retrieval based on keywords, which can be inefficient for some applications. Thus, a document retrieval based on content of the digitized image version of the document can be a more appropriated approach. This paper discusses the retrieval of document images by means of identifying a variety of elements present in the document's image body. We propose a new strategy to identify and combine features extracted from a document image. We also consider the task of constructing an optimized feature set to improve the retrieval performance and to validate our experiments on an assorted database. Experimental results show that the proposed segmentation together with a wisely feature combination increase the overall retrieval performance. Moreover the retrieved images demonstrate the generality and effectiveness of our approach for an efficient ...

2011-01-01

451

Comparative evaluation of /sup 99m/Tc GH, /sup 99m/TcO_4, and /sup 99m/Tc DTPA as brain imaging agents  

International Nuclear Information System (INIS)

The brain imaging properties of /sup 99m/Tc glucoheptonate, /sup 99m/Tc pertechnetate, and /sup 99m/Tc DPTA are compared. Results demonstrate that optimum images are obtained at 90, 180, and 180 min., for /sup 99m/Tc GH, /sup 99m/Tc DTPA, and /sup 99m/Tc pertechnetate, respectively. The former two images are not affected by prior bone imaging with /sup 99m/Tc pyrophosphate, while /sup 99m/Tc pertechnetate images are adversely affected. /sup 99m/Tc glucoheptonate appears to be the superior agent for brain imaging, followed by /sup 99m/Tc DTPA and /sup 99m/Tc pertechnetate.

452

Investigation of respiratory-dependent movements of pulmonary space-occupying lesions with MRI; Untersuchung der atemabhaengigen Bewegungen pulmonaler Raumforderungen mit der MRT  

Energy Technology Data Exchange (ETDEWEB)

Parallel imaging and echo sharing techniques have markedly reduced the acquisition times for MRI of large volumes. Dynamic 2 and 3-dimensional data sets of the chest with high temporal resolution (up to 10 images/s with single slice and 2 volume/s) allow an analysis of respiratory motion of the lungs and tumors. Time-resolved 2D series in preselected planes can be used to observe respiratory motion during free breathing or after respiratory commands, e.g. to exclude chest wall invasion by a tumor or for diagnosing impairment of respiratory mechanics. Time-resolved 3D-series (4D-MRI) allow monitoring of the spatial displacement of the lungs and tumors as a whole volume. Present limitations such as an overestimation of tumor size and an underestimation of displacement due to a limited temporal resolution are expected to be overcome with further technical developments. However, 4D-MRI already appears to be the appropriate tool to select patients ...

2009-08-15

453

The benefits of low level radiation  

Energy Technology Data Exchange (ETDEWEB)

The assumed linear relationship between exposure to radiation and cancer incidence is questioned in this article. The current research data on radiation effects at the cellular level is reviewed, as are epidemiological studies of background radiation effects and health effects of populations exposed to low levels of radiation exposure via employment or medical treatments. Statistics reveal that threshold levels currently in force need to be reviewed. Some evidence of beneficial effects of low level radiation exposure effects of low level radiation exposure is also presented, and so regulations should be reviewed at an international level. (UK).

1997-06-01

454

Stimulated radiation of high - current relativistic electron beams  

International Nuclear Information System (INIS)

The most propagated mechanisms of stimulated radiation of electron beam such as Cherenkov one-particle and collective effects, ondulator and magnetic bremsshrahlung radiations, Doppler anomalous effect, Thompson and Raman scattering and radiation are discussed. Relation of spontaneous radiation mechanisms of individual electron and stimulated radiation effects in electron beams has been elucidated, grounds of linear electrodynamics of radiative beam instabilities are stated, and main mechanisms of their nonlinear stabilization are elucidated as well. Various simulated processes in electron beams are considered from the unique point of view using a simple mathematical apparatus and such physical laws as conservation and Newton laws.

1987-01-01

455

The difference between standard and average efficiencies of multijunction compared with single-junction concentrator cells  

Energy Technology Data Exchange (ETDEWEB)

The theoretical performance of ideal single- and multijunction cells are compared at 100xconcentration under a range of cloudless-sky conditions. The sensitivities of device performance to cell temperature and spectral variations are shown to depend on the number of junctions (one, two or three), the way in which the junctions are connected (series, parallel or independent), and the band gaps of the devices. The average performances of all of the multijunction devices surpass that of a single-junction GaAs device, but the inconsistency in performance of some of the multijunction devices is significant for large variations in cell temperature and incident spectrum. The choice of band gap and connection scheme is more important than the number of junctions in determining the consistency of device performance. (orig.).

1991-05-01

456

Temperature dependence of threshold current of injection lasers for short pulse excitation  

Energy Technology Data Exchange (ETDEWEB)

We report measurements of the temperature dependence of the threshold current of GaAs, 1.3-..mu..m InGaAsP, and 1.5-..mu..m InGaAsP double heterostructure lasers using short electrical pulses. T/sub 0/approx.200 K is observed for all the lasers. These high T/sub 0/ values show that the carrier density at threshold does not increase rapidly with increasing temperature in any of the lasers studied and thus the observed low cw T/sub 0/ of InGaAsP lasers is primarily due to a decrease of the carrier lifetime at threshold with increasing temperature.

1984-05-15

457

Status of nonsilicon photovoltaic solar cell research  

Energy Technology Data Exchange (ETDEWEB)

The current status of non-silicon photovoltaic solar cells is discussed including the identification of current technical and economic issues and future research directions for potential high efficiency low cost technologies. This review covers such advanced materials as CdS/Cu/sub 2/S, CdS/CuInSe/sub 2/, and GaAs homojunction and heterojunction devices; such emerging materials as InP, Zn/sub 3/P/sub 2/ and CdTe; and liquid junction electrochemical photovoltaic cells. An attempt is made to compare the current relative status of these various technologies and to indicate their near term potential where possible. 105 refs.

1980-01-01

458

Satellite power study (SPS) concept definition study (exhibit D). Volume 1: executive summary. Final report  

Energy Technology Data Exchange (ETDEWEB)

Efforts concentrated on updating of the Rockwell reference concept, definition of new system options, studies of special emphasis topics, further definition of the transportation system, and further program definition. The Rockwell reference satellite concept has a gallium arsenide (GaAs) solar cell array having flat concentrators with an effective concentration ratio of 1.83at end of life. Alternatives to this concept includes solid state power amplifiers or magnetrons for dc/RF conversion and multibandgap solar cells for solar to dc energy conversion. Two solid state concepts were studied. It was determined that the magnetron approach was the lowest mass and cost system.

1981-03-01

459

Observation of strain-enhanced electron-spin polarization in photoemission from InGaAs  

International Nuclear Information System (INIS)

Electron-spin polarization in excess of 70% has been observed in photoemission from a 0.1-#mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x#approx#0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single-band transition.

460

New III-V cell design approaches for very high efficiency. Annual subcontract report, 1 August 1990--31 July 1991  

Energy Technology Data Exchange (ETDEWEB)

This report describes progress during the first year of a three-year project. The objective of the research is to examine new design approaches for achieving very high conversion efficiencies. The program is divided into two areas. The first centers on exploring new thin-film approaches specifically designed for III-V semiconductors. The second area centers on exploring design approaches for achieving high conversion efficiencies without requiring extremely high quality material. Research activities consisted of an experimental study of minority carrier recombination in n-type, metal-organic chemical vapor deposition (MOCVD)-deposited GaAs, an assessment of the minority carrier lifetimes in n-GaAs grown by molecular beam epitaxy, and developing a high-efficiency cell fabrication process.

1993-01-01

461

New III-V cell design approaches for very high efficiency  

Energy Technology Data Exchange (ETDEWEB)

This report describes progress during the first year of a three-year project. The objective of the research is to examine new design approaches for achieving very high conversion efficiencies. The program is divided into two areas. The first centers on exploring new thin-film approaches specifically designed for III-V semiconductors. The second area centers on exploring design approaches for achieving high conversion efficiencies without requiring extremely high quality material. Research activities consisted of an experimental study of minority carrier recombination in n-type, metal-organic chemical vapor deposition (MOCVD)-deposited GaAs, an assessment of the minority carrier lifetimes in n-GaAs grown by molecular beam epitaxy, and developing a high-efficiency cell fabrication process.

1993-01-01

462

Microscopic Origin of the Phenomenological Equilibrium ''Doping Limit Rule'' in n -Type III-V Semiconductors  

International Nuclear Information System (INIS)

The highest equilibrium free-carrier doping concentration possible in a given material is limited by the ''pinning energy'' which shows a remarkable universal alignment in each class of semiconductors. Our first-principles total energy calculations reveal that equilibrium n -type doping is ultimately limited by the spontaneous formation of close-shell acceptor defects: the 3- -charged cation vacancy in AlN, GaN, InP, and GaAs and the 1- -charged DX center in AlAs, AlP, and GaP. This explains the alignment of the pinning energies and predicts the maximum equilibrium doping levels in different materials. (c) 2000 The American Physical Society

2000-02-07

463

Materials aspects of multijunction solar cells  

Energy Technology Data Exchange (ETDEWEB)

Atomic layer epitaxy (ALE) was used to grow several components of the cascade solar cell structure in the AlGaAs/GaAs system. An ALE reactor was constructed for multiwafer growth with a growth rate of 0.6 {mu}m h{sup -1}. Device quality GaAs and Al{sub x}Ga{sub 1-x}As films were grown with p-type background carbon doping in the ranges 10{sup 16}-10{sup 19} cm{sup -3} and 10{sup 16}-10{sup 20} cm{sup -3} respectively. N-type films were achieved by SiH{sub 4} doping, producing carrier concentrations in the range 10{sup 16}-10{sup 18} cm{sup -3}. In addition, the potential applications of the ALE technique in the photovoltaic field are discussed. (orig.).

1991-05-01

464

Focused ion beam implantation induced site-selective growth of InAs quantum dots  

International Nuclear Information System (INIS)

The site-selective growth of InAs quantum dots (QDs) by a combined focused ion beam (FIB) and molecular beam epitaxy (MBE) process has been demonstrated. An array of FIB modified spots on MBE grown GaAs was fabricated. Thereafter, an in situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by the FIB. The influences of ion dose, annealing parameters, and InAs amount were investigated. With optimized parameters, the authors observe more than 50% single dot occupancy per holes. Photoluminescence spectra confirm the good optical quality of the QDs.

2007-09-17

465

Diffuse X-ray scattering study of sublattice ordering among group III atoms in In_0_._5Ga_0_._5P and In_0_._5Al_0_._5P  

International Nuclear Information System (INIS)

The intensity of superstructure reflections and associated diffuse scattering from In_0_._5Ga_0_._5P and In_0_._5Al_0_._5P epitaxic layers grown on (001) GaAs substrates was mapped in reciprocal space. The Warren-Cowley short-range-order parameters were obtained through the usual process for evaluating Fourier coefficients. Varying values for the correlation length in different directions indicate how group III atoms stack up in ordered states. The resultant structure with long-range order confirms the hypothesis made on the basis of electron diffraction and high-resolution transmission electron microscopy studies. (orig.).

466

Advances in the development of an AlGaAs/GaAs cascade solar cell using a patterned germanium tunnel interconnect  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we discuss various aspects of the development of an inverted-grown AlGaAs/GaAs cascade solar cell incorporating a patterned germanium tunnel junction. Topics include the development of the Al{sub 0.37}Ga{sub 0.63}As top cell, the growth of the GaAs bottom cell over the patterned germanium tunnel junction, and a technique for selective removal of thin AlGaAs/GaAs heterostructures after lattice-matched growth on germanium substrates. The problems to be overcome for the achievement of around 30% efficiencies in the AlGaAs/GaAs cascade cell under concentrator applications are also discussed. (orig.).

1991-05-01

467

A model for Schottky-barrier solar cell analysis  

Science.gov (United States)

A general model for the analysis of metal-semiconductor solar cells is presented. The model takes into account the cell optical properties, carrier recombination effects, semiconductor minority-carrier properties, series resistance, cell thickness, and active surface area. Numerical methods are used to solve the appropriate continuity equations and hence compute the photocurrent density under AMO conditions. The operation of the model is demonstrated using p- and n-type Si and GaAs with Au being taken as the barrier metal. Calculations are presented showing the effect on solar energy conversion efficiency of surface recombination velocity, barrier height, minority-carrier lifetime, barrier metal thickness, collecting grid configuration, and cell thickness. A comparison of practical and computed data for the Au/n-GaAs system yields good agreement. (AIP)

1976-05-01

468

Subsurface imaging using the spectral polarization difference technique and NIR illumination  

Energy Technology Data Exchange (ETDEWEB)

A subsurface imaging system is utilized to test the ability of the spectral polarization difference imaging technique for deep subsurface imaging in tissues. The illumination of the system is derived from compact class III lasers in the red and NIR spectral region and, alternatively, from a white light source and selection of the appropriate illumination wavelength using band-pass optical filters. The experimental results demonstrate detection and imaging of a high-scattering object located up to 1.5 cm underneath the surface of a host chicken tissue.

1999-01-26

469

Cutaneous gallium uptake in patients with AIDS with mycobacterium avium-intracellulare septicemia  

International Nuclear Information System (INIS)

Gallium imaging is increasingly being used for the early detection of complications in patients with AIDS. A 26-year-old homosexual man who was HIV antibody positive underwent gallium imaging for investigation of possible Pneumocystis carinii pneumonia. Widespread cutaneous focal uptake was seen, which was subsequently shown to be due to mycobacterium avium-intracellulare (MAI) septicemia. This case demonstrates the importance of whole body imaging rather than imaging target areas only, the utility of gallium imaging in aiding the early detection of clinically unsuspected disease, and shows a new pattern of gallium uptake in disseminated MAI infection.

470

Staging of multiple myeloma with MRI: comparison to MSCT and conventional radiography; Staging des multiplen Myeloms mit der MRT: Vergleich zur MSCT und zur konventionellen Roentgendiagnostik  

Energy Technology Data Exchange (ETDEWEB)

The staging of patients with multiple myeloma demands sensitive imaging methods for the assessment of the skeletal system. MRI allows for direct visualization of the bone marrow which exhibits five different infiltration patterns in multiple myeloma: 1. normal appearance of the bone marrow, 2. focal involvement, 3. homogeneous diffuse infiltration, 4. combined diffuse and focal infiltration, 5. ''salt and pepper'' pattern with inhomogeneous bone marrow signals due to multiple fat islands. The combination of T1w-SE and STIR sequences is best suited for detecting all infiltration patterns and for the differential diagnoses e. g. hemangiomas. With parallel imaging in MRI, acquisition times can be markedly reduced and whole-body screening of the bone marrow can be achieved within 30 min. MRI is superior to radiography for the detection of focal as well as diffuse infiltration. Multidetector computed tomography ...

2004-09-01

471

Myocardial imaging in patients with Kawasaki disease. Exercise stress imaging and serial studies  

Energy Technology Data Exchange (ETDEWEB)

Thallium-201 myocardial imaging was performed in 80 children with coronary arterial lesions due to Kawasaki disease in order to assess the value of serial and exercise myocardial imagings. In eight of these children, abnormalities of the image were noted. Twenty children had serial thallium studies with an interval of three to 18 months, and five of these showed changes in the image including appearance of a new perfusion defect in one patient and improvement of perfusion defects in four. These changes of the myocardial image were correlated well with coronary angiographic findings obtained within a few days of the isotope studies. It was noted that the changes of the myocardial image were more frequently observed at relatively recent period recovered from Kawasaki disease. Exercise myocardial imaging using a bicycle ergometer was performed ...

1982-06-01

472

Radiation protection. A guide for scientists and physicians  

International Nuclear Information System (INIS)

This manual was written for individuals who wish to become qualified in radiation protection as an adjunct to working with sources of ionizing radiation or using radionuclides in the field of medicine. It provides the radiation user with information needed to protect himself and others and to understand and comply with governmental and institutional regulations regarding the use of radionuclides and radiation machines. It is designed for a wide spectrum of users, including physicians, research scientists, engineers, and technicians. It should be useful also to radiation safety officers, members of radiation safety committees, and others who are responsible for the proper use of radiation sources, although they may not be working with the sources directly. The presentation in this manual is designed to obviate the need for reviews of atomic ...

473

Combining satellite data and models to estimate cloud radiative effect at the surface and in the atmosphere  

British Library Electronic Table of Contents (United Kingdom)

Abstract Satellite measurements and numerical forecast model reanalysis data are used to compute an updated estimate of the cloud radiative effect on the global multi-annual mean radiative energy budget of the atmosphere and surface. The cloud radiative cooling effect through reflection of short wave radiation dominates over the long wave heating effect, resulting in a net cooling of the climate system of - 21 Wm-2. The short wave radiative effect of cloud is primarily manifest as a reduction in the solar radiation absorbed at the surface of - 53 Wm-2. Clouds impact long wave radiation by heating the moist tropical atmosphere (up to around 40 Wm-2 for global annual means) while enhancing the radiative cooling of the atmosphere over other regions, in particular higher latitudes and sub-trop...

2011-01-01

474

Biological effects of electromagnetic radiation in the microwave range  

Energy Technology Data Exchange (ETDEWEB)

The book examines current experimental and clinical knowledge concerning the biological and biophysical effects of electromagnetic radiation, particularly that in the microwave range. The biophysical bases of the interaction of electromagnetic radiation with matter are reviewed with emphasis on biological systems, and the effects of radiation on critical biological systems, including the nervous, reproductive, visual and blood-forming systems are compared. Data concerning the lethal effects of nonionizing radiation is presented and characteristics of the effects of electromagnetic radiation on the whole mammalian organisms are examined. Various reactions of the neuroendocrine system to electromagnetic radiation are described, with particular attention given to the adrenal system, and the combined effects of ionizing and microwave radiation ...

1980-01-01

475

[The indicators of biological age and accelerated aging in liquidators of the consequences of radiation emergency].  

Science.gov (United States)

The biological age (BA) of the majority of the liquidators of the consequences of the radiation accidents in the Navy and of the liquidators of the Chernobyl' APS accident exceeds the medium standard and the DBA (due BA). The index of the BA can be a characteristic of the influence of the social-hygienic factors on the health condition of the Special Risk Subunit--the liquidators of the consequences of the radiation accidents. It was established, that the radiation influence concerns to the factors dramatically increasing the BA and the rate of senescence of the liquidators of the consequences of the radiation accidents. PMID:21809627

2011-01-01

476

The THz Radiation from Undulator  

Science.gov (United States)

The experimental device for generation of undulator radiation in terahertz wavelength region by use of undulator with ferromagnets is created. The device is based on a beam of a microtron with the energy 7.5 MeV. The radiation wavelength is 200 mu. Registered spontaneous radiation has a power 10{sup -6} W at a current of a beam 2 mA in a pulse. With the optical resonator, in a mode, the amplification of 6% is received, that in sometimes is more than the expected value. This effect is explained as a result of partial coherence of radiation.

2010-02-03

477

Study of emission of Cerenkov radiation by tachyons  

Energy Technology Data Exchange (ETDEWEB)

The emission of Cerenkov radiation by tachyons has been examined by using the reduced expansions of superluminal electromagnetic fields in terms of standard helicity representation of Poincare group. It has been shown that the tachyons emit Cerenkov radiation through their coupling only with subluminal electromagnetic fields and that a charged tachyon can emit Cerenkov radiation only in the media in which it travels with a velocity lower than that of light while in the usual medium in which its velocity is more than that of light, it will never emit Cerenkov radiation.

1983-01-01

478

Radiation facility with electron accelerator of the Institute for Nuclear Research of Ukraine, Kiev  

International Nuclear Information System (INIS)

Characteristics of the Ukrainian NSA NRI radiation facility for scientific researches and developments of industrial radiation technology are performed. Parts of the facility, design peculiarities of technical tools are described. Biological protection of the facility and radiation protection system, transport line, systems of technical provision and radiation measurements are discussed

2003-02-01

479

Radiation exposure of the population of the GDR by X-ray diagnostics  

International Nuclear Information System (INIS)

The radiation burden of the people of the GDR in relation to biomedical radiography altogether as well as organ doses, gonad doses and genetically significant doses in detail are outlined. The concepts of radiation protection and standards of radiographic examination are demonstrated. Possibilities of influencing radiation exposure by scientifically based indication of X-ray examination, application of new and improvement of usual examination techniques are discussed with regard to quality assurance and control. Proposals concerning the reduction of radiation exposure of the GDR population are presented.

1986-01-01

480

Potential Hazards from Neutrino Radiation at Muon Colliders  

CERN Document Server

High energy muon colliders, such as the TeV-scale conceptual designs now being considered, are found to produce enough high energy neutrinos to constitute a potentially serious off-site radiation hazard in the neighbourhood of the accelerator site. A general characterization of this radiation hazard is given, followed by an order-of-magnitude calculation for the off-site annual radiation dose and a discussion of accelerator design and site selection strategies to minimize the radiation hazard.

1999-01-01

481

Coherent oscillator radiation  

International Nuclear Information System (INIS)

Coherent oscillator radiation is considered. A comparison is made with classical particle radiation with gauss distribution. Decay probability for coherent state in spontaneous radiation is estimated. The method suggested for describing harmonic oscillator allows to separate the effect of classical field radiation from quantum description of particle state within the framework of a self-consistent quantum mechanical problem.

1982-04-01

482

Resolution enhancement by subtraction of confocal signals taken at different pinhole sizes.  

Science.gov (United States)

Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in ...

2003-01-01

483

Magnified x-ray phase imaging using asymmetric Bragg reflection: Experiment and theory  

International Nuclear Information System (INIS)

X-ray imaging using asymmetric Bragg reflection in the hard x-ray regime opens the way to improve the spatial resolution limit below 1 #mu#m by magnifying the image before detection, simultaneously providing a strong phase contrast. A theoretical formalism of the imaging process is established. Based on this algorithm, numerical simulations are performed and demonstrate that both Fresnel propagation and Bragg diffraction contribute to contrast formation. The achievable resolution of this technique is investigated theoretically; the results obtained can be used to improve future experimental setups. Furthermore, the minimum detectable phase gradient is estimated, for comparison with other phase sensitive imaging techniques. Results from biological objects demonstrate that the technique is viable for imaging both in two and three dimensions. Refraction contrast ...

2006-08-01

484

Clinical trial of NMR-CT, (4). Clinical evaluation of hybrid image  

Energy Technology Data Exchange (ETDEWEB)

In our evaluation we utilized the Asahi Mark-J NMR-CT system, with a resistive vertical quadrupolar electromagnet (0.1 Tesla) and a proton resonance frequency of 4.5 MHz. Our main imaging methods are the inversion-recovery or IR, saturation-recovery, or SR, and calculated T/sub 1/. Difference, or D images, constructed by subtracting the data of the IR signal from that of the SR signal, have also been obtained in some cases. The system allows averaging of raw data. Hybrid images were constructed from two or more images to obtain clear definition of areas of interest. By using the hybrid image, several tissues of different relaxation times can be shown in the same image. Application in our study of the newly developed hybrid image indicates its importance in the detection and diagnosis of lesion, especially the detection of the differentiation ...

1985-01-01

485

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and ...

1993-12-01

486

Direct digital radiography vs conventional radiography of thoracic spine: a comparative study  

International Nuclear Information System (INIS)

Objective: An evaluation of the application of DR in thoracic spine and a comparative study of the DR with the conventional radiography. Methods: DR images and the conventional radiogram of 89 cases respectively were evaluated by 3 vice-consultant doctors and 2 chief technicians. Statistics was processed with 2 categories: (1) images were classified into grade A, B, C and condemned according to the image quality; and (2) thoracic spine are divided into upper, middle and lower portions, in which the rate of successful imaging were compared respectively. Results: The image quality of DR: 74. 1% images in grade A, 20.2% in grade B, 5.7% in grade C, and no image condemned. Conventional radiogram: 45% images in grade A, 41.6% in grade B, 11.2% in grade C, and 2.2% images condemned. The successful ...

2005-09-01

487

Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase ...

2008-12-15

488

Wet chemical etch solutions for Al{sub x}Ga{sub 1{minus}x}P  

Science.gov (United States)

Heterostructures based on AlGaInP alloy compounds are very attractive for visible semiconductor lasers, heterojunction bipolar transistors (HBTs), and high-electron-mobility transistors (HEMTs) lattice matched to GaAs substrates. Several wet etching solutions for AlGaP of different compositions have been studied. Al{sub 0.5}Ga{sub 0.5}P is found to etch in HF, H{sub 3}PO{sub 4}, hyphosphorous acid (HOPH{sub 2}:O), HCl, KOH, and 1% Br{sub 2}-methanol (MeOH). Etching of Al{sub 0.5}Ga{sub 0.5}P in HCl is reaction limited with an activation energy of {approximately}54.4 kJ/mol. At fixed conditions, the etch rates of Al{sub x}Ga{sub 1{minus}x}P vary exponentially with x in HF and HCl, while in 1% Br{sub 2}-MeOH and mixtures of HCl and HNO{sub 3} the etch rates follow a linear dependence on AlP mole fraction. HF has been found to be a good etchant for AlGaP over InGaP or AlInP with high selectivity, while HCl is useful for the reverse case. The use of 1% Br{sub 2}-MeOH ...

1996-01-01

489

Solid-state precursor routes to III-V type electronic (13-15) and magnetic (3-15) materials  

Science.gov (United States)

An interest in electronic materials has led me to investigate new synthetic approaches to III-V' type semiconducting (13-15, current IUPAC designation for B and N groups in the Periodic Table) and magnetic (3-15) compounds. It is now possible to prepare binary (GaAs and GdP) and ternary mixed-metal (Al[sub x]Ga[sub 1-x]As) and mixed-pnictide (GaP[sub x]As[sub 1-x]) compounds in seconds from rapid, low-temperature-initiated metathesis reactions between a metal (III) trihalide and a trisodium pnictide, exemplified by MX[sub 3] + Na[sub 3]Pn [yields] MPn + 3 NaX, where M is Al, Ga, In, (Al,Ga), or a lanthanide; X is F, Cl, or I; and Pn is P, As, Sb, or (P,As). The precursors are mixed together in a dry box and ignited by light grinding with a mortar and pestle, or by brief, local heating from a hot filament. These reactions are very exothermic (calculated [Delta]H[sub rxn] (GaAs) = 138 kcal/mol) and typically reach temperatures in excess ...

1992-01-01

490

Influence of phosphorus vapor ambient for InGaAsP growth on GaAs substrate  

Science.gov (United States)

For visible-light-emitting laser diodes, InGaAsP double heterostructures have been grown on GaAs substrates using liquid-phase epitaxy. As the growth temperature is as high as about 780 /sup 0/C, a large amount of phosphorus evaporates from the solutions for the cladding layers during the growth process. The phosphorus vapor disturbs the solution composition for the active layer, so that very thin and uniform active layers cannot be obtained. By using In-P-Sn solution and supplying the phosphorus partial pressure around the graphite boat, the influence of phosphorus vapor ambient for InGaAsP (lambda/sub P//sub L/ = 805 nm) growth is confirmed. When the phosphorus partial pressure increases, the surface of epitaxial layer becomes rough and the substrate is partly etched back. From x-ray diffraction and photoluminescence spectral measurements, the composition of the grown layer is also found to be changed. As a result of increasing the flow rate of H/sub 2/ gas in ...

1986-12-01

491

High mobility two-dimensional hole system in GaAs/AlGaAs quantum wells grown on (100) GaAs substrates  

International Nuclear Information System (INIS)

We report on the transport properties of a high mobility two-dimensional hole system (2DHS) confined in GaAs/AlGaAs quantum wells grown by molecular-beam epitaxy on the (100) surface of GaAs. The quantum wells are modulation doped with carbon utilizing a resistive filament source. At T=0.3 K and carrier density p=1x10"1"1 cm"-"2, a mobility of 10"6 cm"2/Vs is achieved. At fixed carrier density p=10"1"1 cm"-"2, the mobility is found to be a nonmonotonic function of the quantum well width. The mobility peaks at 10"6 cm"2/Vs for a 15-nm well and is reduced for both smaller and larger well widths for these (100) samples. The mobility anisotropy is found to be small. Mobility along [011] is approximately 20% higher than along the [011] direction. In addition, the low-temperature carrier density is found to have low sensitivity to light. The hole density increases by only #approx#10% after exposure to red light at T=4.2 K. In structures designed for a lower carrier ...

2005-04-18

492

Development of an IR-transparent, inverted-grown, thin-film, Al[sub 0. 34]Ga[sub 0. 66]As/GaAs cascade solar cell  

Energy Technology Data Exchange (ETDEWEB)

Inverted growth and the development of associated cell processing, are likely to offer a significant degree of freedom for improving the performance of many III-V multijunction cascades and open new avenues for advanced multijunction concepts. This is especially true for the development of high-efficiency Al[sub 0.37]Ga[sub 0.63]As/GaAs cascades where the high growth temperatures required for the AlGaAs top cell growth can cause the deterioration of the tunnel junction interconnect. In the approach of inverted-grown AlGaAs/GaAs cascade cells, the AlGaAs top cell is grown first at 780 [degree]C and the GaAs tunnel junction and bottom cell are grown at 675 [degree]C. After the inverted growth, the AlGaAs/GaAs cascade structure is selectively removed from the parent substrate. The feasibility of inverted growth is demonstrated by a fully-processed, inverted-grown, thin film GaAs cell with a 1-sun AM1.5 efficiency of 20.3%. Also, an inverted-grown, ...

1992-12-01

493

Charge and fluence lifetime measurements of a dc high voltage GaAs photogun at high average current  

Energy Technology Data Exchange (ETDEWEB)

GaAs-based dc high voltage photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed high average current facilities that must operate at tens of milliamperes or more. This paper describes techniques to maintain good vacuum while delivering beam, and techniques that minimize the ill effects of ion bombardment, the dominant mechanism that reduces photocathode yield of a GaAs-based dc high voltage photogun. Experimental results presented here demonstrate enhanced lifetime at high beam currents by: (a) operating with the drive laser beam positioned away from the electrostatic center of the photocathode, (b) limiting the photocathode active area to eliminate photoemission from regions of the photocathode that do not support efficient beam delivery, (c) using a large drive laser beam to distribute ion damage over a larger area, and (d) by applying a relatively low bias ...

2011-04-01

494

Study of implantation damage in germanium formed using Ga"+ FIB  

International Nuclear Information System (INIS)

Full text: It is known that the ion implantation of germanium single crystals at room temperature results in drastic alteration of the germanium surface and the formation of cellular relief. Voids were found into the near-surface damage layer. The intersection of these voids with the germanium surface, as result of sputter etching, forms cellular relief. However, exact mechanism responsible for formation of the voids is not known. A 10 and 30 keV Ga"+ irradiation of Ge #left brace#100#right brace# crystal at room temperature was carried out using a focused ion beam (FIB) system with a dose in the range 0.5x10"1"2 to 1.5x10"1"4 ion/cm"2. The topology of the modified germanium surface and the structure of the radiation damage was studied using imaging facilities of the FIB systems and transmission electron microscopy. The strong cellular structure of Ge was observed after an ion dose of 3x10"1"3 ion/cm"2. High-resolution TEM showed a complex ...

495

Nanofocusing refractive X-ray lenses  

Energy Technology Data Exchange (ETDEWEB)

This thesis is concerned with the optimization and development of the production of nanofocusing refractive X-ray lenses. These optics made of either silicon or diamond are well-suited for high resolution X-ray microscopy. The goal of this work is the design of a reproducible manufacturing process which allows the production of silicon lenses with high precision, high quality and high piece number. Furthermore a process for the production of diamond lenses is to be developed and established. In this work, the theoretical basics of X-rays and their interaction with matter are described. Especially, aspects of synchrotron radiation are emphasized. Important in X-ray microscopy are the different optics. The details, advantages and disadvantages, in particular those of refractive lenses are given. To achieve small X-ray beams well beyond the 100 nm range a small focal length is required. This is achieved in refractive lenses by moving to a compact lens design where ...

2010-02-05

496

Heat Shock Protein 27-Targeted Heptapeptide of the PKC? Catalytic V5 Region Sensitizes Tumors With Radio- and Chemoresistance  

International Nuclear Information System (INIS)

Purpose: Previous data suggest that the PKC? catalytic V5 (PKC?-V5) heptapeptide (HEPT) (FEQFLDI) binds HSP27 and blocks HSP27-mediated radio- or chemoresistance. Here we investigated further the in vivo function of the PKC?-V5 HEPT. Methods and Materials: Labeling of HEPT with Cy5.5 or fluorescein isothiocyanate was performed to evaluate in vitro or in vivo distribution of HEPT. A clonogenic survival assay, flow cytometry, and Western blotting of cleaved caspase-3 were performed to determine in vitro sensitization effects of HEPT plus ionizing radiation (IR) versus IR alone or those of HEPT plus cisplatin(Cis) versus Cis alone. A nude mouse xenografting system was also applied to detect in vivo sensitizing effects of HEPT. Results: HEPT efficiently bound to HSP27 and showed sensitization after combined treatment with IR versus treatment with Cis alone in NCI-H1299 lung carcinoma cells, with higher HSP27 expression, which was similar to that of combined treatment ...

2011-05-01

497

Diagnostic imaging of Thorotrast associated cholangiocarcinoma and mixed hepatocellular and cholangiocellular carcinoma  

International Nuclear Information System (INIS)

Computed tomography would be a better method to detect and characterize a Thorotrast-induced liver tumour. The selective opacification of the RES by Thorotrast creates an intrinsic opacification of the liver similar in effect to contrast agents being evaluated for liver CT, such as ethoioidized oil emulsion. The computed tomographic appearance of Thorotrast-associated cholangiocarcinoma is usually a large, inhomogenous mass composed of disordered area of tissue of high density due to Thorotrast deposits, and of very low density. Thorotrast-induced cholangiocarcinoma originates in the peripheral biliary tree suprounding the highest mean concentration of Thorotrast deposition, so that visible soft tissue masses in the higher density spots in the liver are not produced in the early stage. The tendency for the opacity of the liver to decrease slowly with time and result in an uneven trabeculation and high density spots suggests that small tumors may be difficult to detect againist such an ...

498

CF findings of bowel infarction in 56 surgical patients, 5 of whom with reversible ischemia; Aspetti alla tomografia computerizzata dell'infarto intestinale. 56 pazienti sottoposti a interventi chirurgico di cui 5 con ischemia mesenterica reversibile.  

Energy Technology Data Exchange (ETDEWEB)

Bowel infarction is a rare and typical condition of the elderly; despite improvements in diagnostic imaging and vascular surgery, bowel infarction remains a major cause of acute abdomen, with mortality rates ranging 70-80%. Diagnosis on often late because clinical signs, laboratory data and radiologic findings are a specific. The authors investigated radiographic and particular CT patterns of intestinal infraction in 56 patients submitted to surgery within 12 hours of admission. We also report the CT findings of 5 of these patients who had reversible mesenteric ischemia. CT is more sensitive than radiography and does not exhibit the limitations of angiography (i.e., invasiveness, radiation exposure and complex organization). Therefore CT can presently be considered the method of choice in patients with suspected bowel infarction. [Italian] L'infarto intestinale rappresenta una malattia rara e tipica del soggeto anziano; nonostante il ...

1999-04-01