Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry
A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a ...
2002-01-01
Femtosecond Laser Passivation of GaAs Detector Material
... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...
2008-06-07
Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode
International Nuclear Information System (INIS)
This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are ...
Energy Technology Data Exchange (ETDEWEB)
This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron ...
1999-04-01
Assessment of the effects of pixel loss on image quality in direct digital radiography
Energy Technology Data Exchange (ETDEWEB)
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were ...
2004-03-21
Assessment of the effects of pixel loss on image quality in direct digital radiography
International Nuclear Information System (INIS)
Modern digital radiographic 'flat panel' detectors can exhibit a progressive form of image degradation arising from non-functioning pixels. The effect of these 'dead pixels' on the quantitative image quality measures of modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) is investigated by a simulated degradation of images obtained from an Hologic EPEX system. The effects on the semi-quantitive measures obtained from contrast threshold test objects and resolution gratings are also investigated. Results suggest that the contrast-detail tests often employed in quality assurance measures are not sufficient to reveal the presence of dead pixels until well beyond the recommended replacement point for the flat panel detector. However, measurements of spatial resolution using a line pairs phantom were found to be more sensitive to ...
2004-03-21
Single event effects in the pixel readout chip for BTeV
Energy Technology Data Exchange (ETDEWEB)
In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.
2001-12-07
GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy
Energy Technology Data Exchange (ETDEWEB)
High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction ...
2004-12-21
A Detector for 2-D Neutron Imaging for the Spallation Neutron Source
Energy Technology Data Exchange (ETDEWEB)
Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)
2006-07-01
GaAs detector optimization for different medical imaging applications
International Nuclear Information System (INIS)
We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)
1999-09-11
Position-sensitive spectroscopy of 252Cf fission fragments
International Nuclear Information System (INIS)
The fission fragments from spontaneous fission of 252Cf have been measured with the spectrometric and position-sensitive semiconductor pixel detector Medipix2. Fragments are identified by pattern recognition of clusters generated in the Medipix2 pixel matrix sensor upon heavy particle hit. From analysis of cluster area, the distribution of kinetic energy of fission fragments is obtained. Together with a novel USB readout interface, the Medipix2/USB system operates as active nuclear emulsion in single-quantum and on-line tracking mode.
2007-05-11
Multi-spectral schottky barrier infrared radiation detection array
Energy Technology Data Exchange (ETDEWEB)
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
1983-12-27
Multi-spectral schottky barrier infrared radiation detection array
International Nuclear Information System (INIS)
A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.
Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors
This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background ...
2004-01-01
A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector
British Library Electronic Table of Contents (United Kingdom)
An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...
2007-01-01
A comparison of x-ray detectors for mouse CT imaging
International Nuclear Information System (INIS)
There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum ...
2004-12-07
Track clustering and vertexing algorithm for L1 trigger
Energy Technology Data Exchange (ETDEWEB)
One of the keystones of the canceled BTeV experiment (proposed at Fermilab's Tevatron) was its sophisticated three-level trigger. The trigger was designed to reject 99.9% of light-quark background events and retain a large number of B decays. The BTeV Pixel Detector provided a 3-dimensional, high resolution tracking system to detect B signatures. The Level 1 pixel detector trigger was proposed as a two stage process, a track-segment finder and a vertex finder which analyzed every accelerator crossing. In simulations the track-segment finder stage outputs an average of 200 track-segments per accelerator crossing (2.5MHz). The vertexing stage finds vertices and associates track-segments with the vertices found. This paper proposes a novel adaptive pattern recognition model to find the number and the estimated location of vertices, and to cluster track-segments around those vertices. The track ...
2005-10-01
Temperature dependence of the performance of ultraviolet detectors
Energy Technology Data Exchange (ETDEWEB)
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile ...
2003-08-21
Temperature dependence of the performance of ultraviolet detectors
International Nuclear Information System (INIS)
We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause fluctuations in the profile ...
2003-08-21
The Micro-X Imaging Spectrometer Instrument
The Micro-X instrument is a NASA funded, rocket borne X-ray imaging spectrometer planned for launch in January 2011. An array of Transition Edge Sensors (TESs) will observe incoming photons in the 0.2-3 keV energy band with an energy resolution of 2-4 eV at 1 keV. This will be a substantial improvement over current non-dispersive detectors for X-ray spectroscopy of extended sources and will be the first demonstration of a TES-based microcalorimeter in space. The TESs will utilize the 50 mK stage of an Adiabatic Demagnetization Refrigerator (ADR) as a heat sink, and will be read out by a SQUID time division multiplexer. X-rays will be focused onto the TES array of 128 pixels on a 600 micron pitch by a conically approximated Wolter optic with an effective area of 200 cm2. The spectrometer will have a field of view of 11.8 arcmin. We describe the design and development progress of the instrument.
2010-01-01
Advantages of magnification in digital phase-contrast mammography using a practical X-ray tube
Energy Technology Data Exchange (ETDEWEB)
Phase-contrast imaging with a practical cone-beam X-ray tube has been realized for clinical use in digital mammography using computed radiography (CR). To perform phase-contrast imaging, the X-ray detector must be distanced from an object so that the phase-contrast image achieves magnification; in a mammography unit dedicated to phase-contrast imaging, the magnification ratio is 1.75. When using an X-ray tube with a 0.1-mm focal spot, it appears that the penumbra in magnification blurs both projected images and the phase contrast, which generates an edge effect. However, where the sampling pitch of the CR plate is 43.75 {mu}m, the blur stretches the width of the phase contrast so that unit pixels in the detector can capture it. Note that the width of an ideal phase contrast using an X-ray point source results in a phase contrast too narrow for detection with CR. In addition to phase contrast improving image quality, a ...
2008-12-15
Energy Technology Data Exchange (ETDEWEB)
A procedure and software have been developed to transform the area distribution of the residual surface heights available from the measurement with the Micromap interferometric microscope into a two-dimensional (2D) power spectral density (PSD) distribution of the surface height. The procedure incorporates correction of one of the spectral distortions of the PSD measurement. The distortion appears as a shape difference between the tangential and sagittal PSD spectra deduced from the 2D PSD distribution for an isotropic surface. A detailed investigation of the origin of the anisotropy was performed, and a mathematical model was developed and used to correct the distortion. The correction employs a modulation transfer function (MTF) of the detector deduced analytically based on an experimentally confirmed assumption about the origin of the anisotropy due to the asymmetry of the read-out process of the instrument's CCD camera. The correction function has only ...
2005-05-12
The NIR Upgrade to the SALT Robert Stobie Spectrograph
The near infrared (NIR) upgrade to the Robert Stobie Spectrograph (RSS) on the Southern African Large Telescope (SALT), RSS/NIR, extends the spectral coverage of all modes of the visible arm. The RSS/NIR is a low to medium resolution spectrograph with broadband imaging, spectropolarimetric, and Fabry-Perot imaging capabilities. The visible and NIR arms can be used simultaneously to extend spectral coverage from approximately 3200 A to 1.6 um. Both arms utilize high efficiency volume phase holographic gratings via articulating gratings and cameras. The NIR camera is designed around a 2048x2048 HAWAII-2RG detector housed in a cryogenic dewar. The Epps optical design of the camera consists of 6 spherical elements, providing sub-pixel rms image sizes of 7.5 +/- 1.0 um over all wavelengths and field angles. The exact long wavelength cutoff is yet to be determined in a detailed thermal analysis and will depend on the semi-warm instrument cooling ...
2006-01-01
Space Radiation Detector with Spherical Geometry
A particle detector is provided, the particle detector including a spherical Cherenkov detector, and
2011-01-01
Optical Processing of Microwave Signals - Part B
... switching off all the pixels causes all the spectrum lines to disappear (top of Figure 6), next, that switching off one ... Acousto-optic spectrum analyser ...
2003-04-01
Multi-Robot Operator Control Unit
... see http://www.spawar.navy.mil/robots/ ), during which ... pixel-accurate routes for a small ground robot using aerial ... a USV, a UAV and a UUV as well ...
2006-04-01
CBSD Version 2 Component Models of the IR Celestial ...
... 1-sigma ZOHF pixel-to-plxel statistical fluctuations ... Spatial frequency filtering shows distinct bands, but miss ... LOS emissivity at the point of closest ...
1990-12-07
Efficiency of silicon and GaAs concentrator solar cells operated inside integrating cavity receivers
Energy Technology Data Exchange (ETDEWEB)
The theory for the general case of solar cells operating inside integrating cavity receivers is established. This is applied to the particular case of different configurations of silicon and GaAs cells. The results of the analysis show that a composite system of silicon and GaAs cells manufactured using relatively simple technology could reach an efficiency of 34%. The optimal configuration is that in which the GaAs cells are placed in the directly illuminated area of the receiver and the silicon cells are placed in the indirectly illuminated area of the receiver. (orig.).
1991-06-01
Energy Technology Data Exchange (ETDEWEB)
ICP emission analyses are prone to errors due to changes in power level, nebulization rate, plasma temperature, and sample matrix. As a result, accurate analyses of complex samples often require frequent bracketing with matrix matched standards. Information needed to track and correct the matrix errors is contained in the emission spectrum. But most commercial software packages use only the analyte line emission to determine concentrations. Changes in plasma temperature and the nebulization rate are reflected by changes in the hydrogen line widths, the oxygen emission, and neutral ion line ratios. Argon and off-line emissions provide a measure to correct the power level and the background scattering occurring in the polychromator. The authors` studies indicated that changes in the intensity of the Ar 404.4 nm line readily flag most matrix and plasma condition modifications. Carbon lines can be used to monitor the impact of organics on the analyses and calcium and argon lines can be ...
1997-10-01
Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging
International Nuclear Information System (INIS)
Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope configuration ...
Deep-level defects and numerical simulation of radiation damage in GaAs solar cells
Energy Technology Data Exchange (ETDEWEB)
A review of the deep-level defects observed in both electron- and proton-irradiated GaAs solar cells is presented. Studies of the effects of periodic and continuous thermal annealing on the radiation-induced electron and hole traps and the recombination parameters in GaAs solar cells were made for a wide range of electron and proton energies, fluence, annealing temperature and annealing time. A refined model for numerical simulations of the displacement damage was developed for computing the defect density and the cell parameters in the electron- and proton-irradiated GaAs solar cells. Excellent agreement was obtained between the calculated values and the experimental data for the proton-irradiated GaAs solar cells. (orig.).
1991-09-01
Development of high-efficiency GaAs solar cells on polycrystalline Ge substrates
Energy Technology Data Exchange (ETDEWEB)
Progress in the development of high-efficiency GaAs solar cells on low-cost, large-area, large-grain, optical-grade polycrystalline Ge substrates is described in this paper. First, we present results on the growth of specular GaAs-AlGaAs layers, across the various crystalline orientations of a polycrystalline Ge substrate, by metallorganic chemical vapor deposition (MOCVD). Second, we present the preliminary optimization of minority-carrier properties of GaAs-AlGaAs structures on poly-Ge substrates towards the improvement of GaAs solar cells. We have demonstrated comparable minority-carrier lifetimes in GaAs double-hetero structures grown on optical-grade poly-Ge substrates and electronic-grade single-crystal Ge substrates. In addition, we describe device-structure optimization that have led us to achieve a open-circuit voltage of {approximately}1 Volt in a GaAs solar cell on poly-Ge and to improve our ...
1996-01-01
Focused ion beam sculpting curved shapes.
Energy Technology Data Exchange (ETDEWEB)
A focused ion beam (FIB) is used to accurately sculpt predetermined micron-scale, curved shapes in a number of solids. Using a digitally scanned ion beam system, various features are sputtered including hemispheres and sine waves having dimensions from 1-50 {micro}m. Ion sculpting is accomplished by changing pixel dwell time within individual boustrophedonic scans. The pixel dwell times used to sculpt a given shape are determined prior to milling and account for the material-specific, angle-dependent sputter yield, Y({theta}), as well as the amount of beam overlap in adjacent pixels. A number of target materials, including C, Au and Si, are accurately sculpted using this method. For several target materials, the curved feature shape closely matches the intended shape with milled feature depths within 5% of intended values.
2005-02-01
The Structural and Optical Properties of GaAs1-xPx /GaAs
International Nuclear Information System (INIS)
GaAs1-xPx p-n junction structures were grown on the epi-ready n-type GaAs(100) substrate by solid source MBE system for different phosphor compositions. To obtain the lattice-match sample structure was applied graded growth procedure. The structural and optical properties of the sample structures with different P concentration were investigated by using X-ray diffraction (XRD), spectroscopic ellipsometry (SE). In addition, The range of lattice parameters in the graded epilayer and phosphorous composition were determined from the HRXRD rocking curve simulation. We analyse dielectric function spectra of disordered GaAs1-xPx junction structures measured using spectroscopic ellipsometry at room temperature in the 0.6-4.7 eV photon energy region. The critical energy points such as band gap energy and spin-orbit-split energy of these structures were determined using SE data. It is detected that E0, E1 ,E2 energies of the ...
2008-08-25
Surface-plasma interactions in GaAs subjected to capacitively coupled RF plasmas
Surface compositional changes in GaAs due to RF plasmas of different gases have been investigated by XPS and etch rates were measured using AFM. Angular Resolved XPS (ARXPS) was also employed for depth analysis of the composition of the surface layers. An important role in this study was determination of oxide thickness using XPS data. The study of surface - plasma interaction was undertaken by correlating results of surface analysis with plasma diagnosis. Different experiments were designed to accurately measure the BEs associated with the Ga 3d, Ga 2p sub 3 sub / sub 2 and LMM peaks using XPS analysis and propose identification in terms of the oxides of GaAs. Along with GaAs wafers, some reference compounds such as metallic Ga and Ga sub 2 O sub 3 powder were used. A separate study aiming the identification of the GaAs surface oxides formed on the GaAs surface during and after ...
2002-01-01
Polycrystalline MBE-grown GaAs for solar cells
Energy Technology Data Exchange (ETDEWEB)
This paper will discuss initial studies of thin-film GaAs grown by molecular-beam epitaxy for use in developing a thin-film GaAs solar cell. Photocurrent and photoluminescence intensity are related to the material morphology as a function of growth conditions. Growth temperature and V/III ratio have a dramatic effect on the photocurrent. However, it seems likely that even after optimizing such growth parameters, it will be necessary to provide substrates that can provide templates to enhance grain size from the start of thin-film growth. {copyright} {ital 1997 American Institute of Physics.}
1997-02-01
GaInP[sub 2]/GaAs tandem cells: Problems and solutions
Energy Technology Data Exchange (ETDEWEB)
The various factors that affect the open-circuit voltage ([ital V][sub oc]) of a two-terminal GaInP[sub 2]/GaAs tandem cell are examined. These include a) an anomalous problem associated with the GaAs bottom cell and b) back surface passivation of the thin GaInP[sub 2] top cell. Solutions to these problems are presented and yield tandem [ital V][sub oc]s close to the practical theoretical limits.
1992-12-01
Formation and coarsening of Ga droplets on focused-ion-beam irradiated GaAs surfaces
International Nuclear Information System (INIS)
We have investigated the formation and coarsening of Ga droplets on focused-ion-beam (FIB) irradiated GaAs surfaces. To separately examine formation and coarsening, Ga droplets were fabricated by Ga"+ FIB irradiation of GaAs substrates with and without pre-patterned holes. We determined the droplet growth rate and size distribution as a function of FIB energy following irradiation. The data suggest a droplet formation mechanism that involves Ga precipitation from a Ga-rich layer, followed by droplet coarsening via a combination of diffusion and Ostwald ripening or coalescence via droplet migration (dynamic coalescence).
2009-10-12
UK PubMed Central (United Kingdom)
An examination of the noise of polycrystalline silicon thin film transistors, in the context of flat panel x-ray imager development, is reported. The study was conducted in the spirit of exploring...Full Text Available
2008-01-01
Catheter Ablation for Paroxysmal Atrial Fibrillation
... catheter ablation for paroxysmal atrial fibrillation procedure utilizing 3-D mapping and rotational intracardiac echocardiography. This program is ... of the MRI scan and then there's the 3-D image, which is generated from the pixels chosen ...
Phase formation sequence in the Pd-GaAs system
Energy Technology Data Exchange (ETDEWEB)
The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.
1985-12-01
MOCVD growth of GaAs solar cells on silicon substrates
Energy Technology Data Exchange (ETDEWEB)
This paper reports advances in the development of solar cells made from GaAs-on-Si structures prepared by metalorganic chemical vapor deposition (MOCVD). The use of concentrator cells, operating at [similar to]200 suns, has led to the efficiency achievements of 21.3% (AM1.5D) for a GaAs-on-Si solar cell, and 27.6 (AM1.5D) for a homoepitaxial GaAs cell. The development of epitaxial multilayer dielectric mirrors (Bragg reflectors), as back-surface reflectors in thin-film GaAs cells, on both Si and GaAs substrates, is shown to lead to modest efficiency increases, over that of conventional designs.
1992-12-01
Antiferromagnetic ordering of defects in GaAs
Energy Technology Data Exchange (ETDEWEB)
The magnetic susceptibility of GaAs samples containing a large concentration of native defects was investigated by dc magnetization measurements. Thin GaAs films grown by molecular-beam epitaxy at very low temperatures and bulk GaAs:S samples irradiated with fast neutrons have been studied. For all samples, the susceptibility follows a Curie-Weiss law, indicating the presence of localized magnetic moments. These moments are attributed to unpaired spins located at the native defects. Negative Curie-Weiss temperatures found for both neutron-irradiated and low-temperature-grown GaAs is a clear manifestation of an antiferromagnetic interaction between the moments. The presence of a highly inhomogeneous distribution of native defects has to be assumed to account for the observed antiferromagnetic ordering.
1992-10-15
Ferromagnetism in Mn-doped GaAs layers: Effects of laser annealing
Energy Technology Data Exchange (ETDEWEB)
The properties of Mn-doped GaAs layers grown by laser deposition were investigated with measurements of Hall effect and magneto-optical Kerr effect (MOKE). The electrical and magnetic parameters of the layers were defined by growth temperature and quantity of sputtered Mn. It was shown that room-temperature ferromagnetism is revealed by MOKE and, after ruby laser 25 ns pulse annealing, by Hall effect measurements.
2006-05-15
Energy Technology Data Exchange (ETDEWEB)
The aim of this thesis is to study the coherent transport in semiconducting-superconducting junctions. The SnPb-GaAs system has been studied. It has been shown that the behaviour of this junction is controlled by the disordered area induced by the annealing of the connection near the interface. For a few resistant junction, a conductance anomaly under the gap has been observed and has been explained by a mesoscopic effect in the limit of the very high disorders. The conductance of more resistant junctions has only been bound to the properties of the very disordered area of the semiconductor. The part of the electron-electron interactions on the phase coherence length and on the conductance has been studied. The evolving of the correction of the conductance due to interactions in magnetic field has been followed. The effect of the spin degeneration suppression in CdTe and the GaAs sign inversion in Shubnikov de Haas oscillations rate has been observed. At last has ...
1997-11-07
GaAs concentrator cell production cost analysis
Energy Technology Data Exchange (ETDEWEB)
The utilization of GaAs in photovoltaic (PV) applications has been hindered by the cost of substrates and processing. This paper examines the cost effectiveness of GaAs cells for use in concentrator modules when produced at the 10 to 50 MW level per year. Information on costs associated with substrates, epitaxial processing, and subsequent device fabrication will be compared to allowable costs as projected by the US Department of Energy (DOE). The high cot of GaAs solar cells can be mitigated by use of low-cost substrates or high-concentration systems. The costs then can be accommodated when the production level is sufficiently high to take advantage of economies of scale in device processing and substrate price benefits when procured at high volumes. We have found that development of processing equipment, both for the epitaxial growth and device processing, is the key to obtaining production costs consistent with DOE ...
1992-12-01
A doubly Q-switched laser with both an acousto-optic (AO) modulator and a GaAs saturable absorber can obtain a more symmetric and shorter pulse with high pulse peak power, which has been experimentally proved. The key parameters of an optimally coupled doubly Q-switched laser with both an AO modulator and a GaAs saturable absorber are determined, and a group of general curves are generated for what we believe is the first time, when the single-photon absorption (SPA) and two-photon absorption (TPA) processes of GaAs are combined, and the Gaussian spatial distributions of the intracavity photon density and the initial population-inversion density as well as the influence of the AO Q-switch are considered. These key parameters include the optimal normalized coupling parameter, the optimal normalized GaAs saturable absorber parameters, and the normalized parameters of the AO Q-switch, which can maximize ...
2007-08-20
Energy Technology Data Exchange (ETDEWEB)
To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design
2006-12-04
"Mtrack 2.0": An ultra-scale tracking algorithm for low-resolution overhead imagery
Energy Technology Data Exchange (ETDEWEB)
Overhead persistent surveillance systems are becoming more capable at acquiring wide-field image sequences for long time-spans. The need to exploit this data is becoming ever greater. The ability to track a single vehicle of interest or to track all the observable vehicles, which may number in the thousands, over large, cluttered regions while they persist in the imagery is very desirable. Typically, this imagery has many thousands of pixels on a side and is characterized by lower resolutions (e.g. {approx}0.5 meters/pixel to {approx}2.0 meters/pixel) and lower frame rates (e.g. {approx} sub-Hz to several Hz). We describe our ultra-scale capable implementation of a multiple-vehicle tracking algorithm for overhead persistent surveillance imagery. This work builds upon an earlier report, where now the algorithm has been modified for improved performance and has been substantially improved to handle much larger datasets in a ...
2008-09-26
Small world when building a particle detector prototype, the devil is in the tiny details
Small world when building a particle detector prototype, the devil is in the tiny details
2004-01-01
Photodiode Scintillation Detector for Anti-Coincidence Shielding
Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...
Radiation tolerant GaAs MESFET with a highly-doped thin active layer grown by OMVPE
International Nuclear Information System (INIS)
A new structure of GaAs MESFET with high radiation tolerance is proposed. Changes in electrical parameters of a GaAs MESFET as a function of total #gamma#-ray dose have been found to be caused mainly by a decrease in the effective carrier concentration in an active layer. The authors have designed a new structure from a simulation based on an empirical relationship between the changes of the effective carrier concentration and the total #gamma#-ray dose. It has been successfully demonstrated by utilizing a highly-doped thin active layer (4 x 10"1"8 cm"-"3, 100 Angstrom) grown by OMVPE. This MESFET can withstand a dose ten times higher [1 x 10"9 rads(GaAs)] than a conventional one can.
1990-07-16
Metastable one- and two-electron donor states in GaAs and CdF{sub 2}
Energy Technology Data Exchange (ETDEWEB)
The strongly localized one-electron (D{sup 0}) and two-electron (D{sup -}) donor states are considered with the lattice deformation around the donor center taken into account. For GaAs, donor energy levels have been calculated as functions of the hydrostatic pressure. The calculated energy positions and pressure coefficients agree with the experimental data. It is shown that the interaction with phonons reduces the probability of radiative transitions between the states of different localization and leads to the metastability of shallow-level donor states with respect to the D{sup -} state in GaAs and both the states (D{sup 0} and D{sup -}) in CdF{sub 2}. (author) 7 refs, 1 fig
1996-12-31
Adhesion studies of Au films on GaAs using ion-assisted deposition techniques
International Nuclear Information System (INIS)
This paper reports on a series of experiments performed to examine the ability of ion beam assisted thermal deposition to produce good adhesion of Au metallization on GaAs left-angle 100 right-angle substrates. A study of the influence of Ar ion-assisted thermal deposition of the Au films as well as in situ pre-sputtering of the GaAs surface with low-energy Ar ions prior to thermal deposition, shows that strong adhesion can be achieved without resorting to chemical cleaning. The substrate temperature and the relative flux of Ar ions to incident Au atoms were varied in order to correlate these parameters with film adhesion. The interfaces of films processed under these various conditions were examined by XTEM, RBS and XPS. Orientation texture was studied by x-ray diffraction (XRD).
5 GHz GaAs monolithic astable multivibrator type voltage controlled oscillator
A 5 GHz GaAs monolithic astable multivibrator-type voltage-controlled oscillator has been developed. The monolithic oscillator uses 2 micron long self-aligned TiW-silicide gate MESFETs as well as GaAs Schottky diodes for capacitance. Good agreement between the experiment and calculations for oscillation frequency characteristics versus control voltage is obtained by assuming donor density in the FET active layer to be a Gaussian distribution. This oscillator is useful for monolithic front ends and phase-locked oscillators used in microwave signal processing. X-band oscillation frequency can be obtained with 1 micron long gate FET and low loss resonance inductors.
1984-03-01
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
British Library Electronic Table of Contents (United Kingdom)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the gamma function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the l...
2011-01-01
Quantitative 1-123 IMP SPECT, MR imaging, and neuropsychologic testing in AIDS dementia
International Nuclear Information System (INIS)
The authors have performed I-123 IMP single- photon emission CT (SPECT) brain imaging on seven mildly demented patients with acquired immunodeficiency syndrome (AIDS) and on seven normal subjects. Pixel-intensity histograms have been analyzed for the fraction of pixels in the lowest quartile of the intensity range. This fraction (F) averaged 17.7% (standard deviation [SD] = 4.3) in the AIDS group and 12.6 (SD = 4.7) in the normal group (P <.05). Regression analysis of neuropsychological testing (NPT) scores vs F yielded a correlation coefficient of.71. The presence or degree of atrophy did not correlate with F or NPT scores.
British Library Electronic Table of Contents (United Kingdom)
Even if there have been efforts to validate remote-sensing-based energy balance models, which provide evapotranspiration (ET) maps over a large spatial scale, few studies have been conducted to validate their performance in Korea. In this study, surface energy balance fluxes including ET were estimated and inter-compared with two different models using the Landsat-5 Thematic Mapper (TM) image over a watershed scale in Korea. While there were larger spatial discrepancies for net radiation, soil heat and sensible heat fluxes on a pixel-by-pixel basis between the two models, relatively smaller spatial discrepancies for the latent heat flux and daily ET were detected. The spatial discrepancies for the daily ET were larger in low topography and dense vegetation ranges. Despite the different par...
2011-01-01
British Library Electronic Table of Contents (United Kingdom)
Root growth is a highly dynamic process influenced by genetic background and environment. This paper reports the development of R scripts that enable root growth kinematic analysis that complements a new motion analysis tool: PlantVis. Root growth of Arabidopsis thaliana expressing a plasma membrane targeted GFP (C24 and Columbia 35S:LTI6b-EGFP) was imaged using time-lapse confocal laser scanning microscopy. Displacement of individual pixels in the time-lapse sequences was estimated automatically by PlantVis, producing dense motion vector fields. R scripts were developed to extract kinematic growth parameters and report displacement to ?0.1 pixel. In contrast to other currently available tools, Plantvis-R delivered root velocity profiles without interpolation or averaging across the root s...
2011-01-01
Advanced readout integrated circuit signal processing
Readout integrated circuits (ROICs) for focal plane arrays (FPAs) have become increasingly complex to meet the needs of modern infrared systems. BAE Systems has pioneered a number of advanced signal processing architectures for FPA ROICs. Demonstrated signal processing capabilities of BAE Systems FPAs include analog-to-digital conversion, offset subtraction, individual pixel automatic gain compensation, transient noise suppression, on-FPA defect deselection, reconfigurable pixels, spatial neural network processing and subframe noise averaging. BAE Systems FPA advanced signal processing is not just for demonstrations, but is used in many of their deliverable FPAs, improving real system performance.
2006-06-01
A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor
Energy Technology Data Exchange (ETDEWEB)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10{sup 6} n/cm{sup 2} s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
2002-07-01
A tomography system at the thermal neutron column of the ENEA Casaccia TRIGA reactor
International Nuclear Information System (INIS)
The developed system is intended for use at a collimated thermal neutron beam with a flux of about 10"6 n/cm"2 s. The system works with a cooled CCD array (192 x 165 pixels) and an intensifier for light from a NE426 scintillator with traditional optical coupling. A fine mechanical regulation system allows an accurate positioning of the tomographer, also ensuring the alignment of the CCD array with the rotation and translation axes. The acquisition of 200 projections is carried out in about 30 min with a reconstruction time (40 min max) depending on the reconstruction-matrix order. Radiography and tomography of significant objects are illustrated. The reconstruction algorithm, including spatial and temporal inhomogeneity corrections and filters, was tested with good results for projections up to 512 x 512 pixels. (orig.)
High-efficiency GaAs solar cells on mm and sub-mm grain-size polycrystalline Ge substrates
Energy Technology Data Exchange (ETDEWEB)
GaAs material and device structure optimization studies on optical-grade, millimeter-and-less grain-size polycrystalline Ge substrates are presented. We discuss the growth of high-quality epitaxial layers across various crystalline orientations of a polycrystalline substrate; this is important for obtaining high-performance solar cells. The GaAs solar cell on n-type poly-Ge substrate is a p-on-n type, with an undoped spacer between the p-emitter and the n-base. An experimental study of dark currents in these junctions, with and without the spacer, as a function of temperature (77K to 288K) is presented; this study suggests that the spacer reduces the tunneling contribution to dark current. In addition, we describe device-structure optimization studies that have led us to achieve an open-circuit voltage (V{sub oc}) exceeding 1 Volt and an AM1.5 efficiency of {approximately}19{percent} for a 4-cm{sup 2}-area GaAs cell on ...
1997-02-01
High Efficiency Thin-Fili, GaAs Solar Cells - NASA Technical ...
Metal-Semiconductor Solar Cells," J. Appl. Phys. 46,. 1286 (1975). 12) H. B. Kim , G. G. Sweeney and I. S. Heng, "Analysis of ...
GaAs REI,IABILITY DATARASE '-r. SACCO, S . C+ ON Z, AItIli ...
Direct coupljng between Al and Au metal]jzations can result in an increase in gate resistance due to a metallurgical reaction. (purple plague). An RF life test on ...
Formation Energies of Antiphase Boundaries in GaAs and GaP: An ab Initio Study
UK PubMed Central (United Kingdom)
Electronic and structural properties of antiphase boundaries in group III-V semiconductor compounds have been receiving increased attention due to the potential to integration of optically-active III-V...Full Text Available
Development of GaInAsP for GaInAsP/Ge cascade solar cells
Energy Technology Data Exchange (ETDEWEB)
Quaternary semiconductor compounds are ideal candidates for use in monolithic cascade solar cells because the lattice constant and the bandgap of such compounds can be independently varied. The quaternary semiconductor compound Ga[sub 0.83]In[sub 0.17]As[sub 0.67]P[sub 0.33] not only is lattice matched to GaAs and Ge but also provides a current matched top cell for the GaInAsP/Ge monolithic cascade solar cell. Under concentration of 100 suns, the projected efficiency for such a cell is about 34%. The growth of Ga[sub 0.83]In[sub 0.17]As[sub 0.67]P[sub 0.33] lattice matched to GaAs and Ge has been demonstrated. GaInAsP solar cells have been grown on both GaAs and Ge substrates. A GaInAsP on GaAs solar cell with an active area efficiency of 23.2% for 1 sun, AM 1.5 direct illumination has been prepared. A proposed structure for the GaInAsP/Ge cascade cell is also given.
1992-12-01
Review of the application of molecular beam epitaxy for high efficiency solar cell research
Energy Technology Data Exchange (ETDEWEB)
In the last two years, rapid progress has been made in the energy conversion efficiencies of GaAs solar cells fabricated from molecular beam epitaxy (MBE) material. The efficiencies of cells fabricated from MBE material are now comparable with those fabricated from metal-organic chemical vapor deposition material, even for cells of dimension 2 cmx4 cm. This paper reviews the progress in MBE cell efficiencies. Also discussed is the role oval defects play in GaAs diode and solar cell performance. (orig.).
1991-05-01
Quasi-elastic electron scattering by GaAs surface
International Nuclear Information System (INIS)
Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).
1994-03-20
By gas-source molecular-beam epitaxy, we obtained a device-quality GaInP epitaxial layer lattice matched to (100)-GaAs substrates, with a photoluminescence efficiency comparable to that of a crystal grown by liquid-phase epitaxy. A GaInP/AlInP double heterostructure laser with a GaInP active layer was fabricated, and pulsed lasing operation was achieved at room temperature for, we believe, the first time.
1989-11-01
Schottky barrier and homojunction gallium arsenide solar cells
Energy Technology Data Exchange (ETDEWEB)
New techniques were developed to construct Schottky barrier and homojunction solar cells on GaAs substrates. Schottky barrier metal-semiconductor solar cells were produced for the first time on p-type GaAs substrate using a sputter-deposition method to form the barrier. The sputter deposition of gold or gold/palladium is the key to the method since normal thermal evaporation of gold onto p-type GaAs produces ohmic contacts. The results of this investigation are consistent with the idea that sputter damage produces donor type surface states on GaAs. Barrier heights were measured for both p-type sputtered and n-type thermally evaporated diodes using current-voltage and capacitance-voltage methods. Deep-level transient spectroscopy was used to identify the trap center concentration and energy levels for both diodes in an effort to explain the relatively large dark current in the p-type sputtered diodes. ...
1983-01-01
Neutron radiography with the cyclotron, 6
International Nuclear Information System (INIS)
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
1988-01-01
Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen
International Nuclear Information System (INIS)
For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.
2009-11-01
Energy Technology Data Exchange (ETDEWEB)
In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).
1993-12-01
Bragg curve spectroscopy detector for particle identification
International Nuclear Information System (INIS)
The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.
First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry
Energy Technology Data Exchange (ETDEWEB)
A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.
2010-01-01
First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry
Energy Technology Data Exchange (ETDEWEB)
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
2008-10-01
Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System
Energy Technology Data Exchange (ETDEWEB)
This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.
1999-06-01
First results from the Lund NMP particle detector system
International Nuclear Information System (INIS)
The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.
2009-06-15
First results from the Lund NMP particle detector system
British Library Electronic Table of Contents (United Kingdom)
The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.
2009-01-01
Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector
Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector
1993-01-01
A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer
1991-01-01
Energy Technology Data Exchange (ETDEWEB)
A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The ...
2003-03-04
Time-resolved resonance and linewidth of an ultrafast switched GaAs/AlAs microcavity
We explore a planar GaAs/AlAs photonic microcavity using pump-probe spectroscopy. Free carriers are excited in the GaAs with short pump pulses. The time-resolved reflectivity is spectrally resolved short probe pulses. We show experimentally that the cavity resonance and its width depend on the dynamic refractive index of both the lambda-slab and the lambda/4 GaAs mirrors. We clearly observe a double exponential relaxation of both the the cavity resonance and its width, which is due to the different recombination timescales in the lambda-slab and the mirrors. In particular, the relaxation time due to the GaAs mirrors approaches the photon storage time of the cavity, a regime for which nonlinear effects have been predicted. The strongly non-single exponential behavior of the resonance and the width is in excellent agreement to a transfer-matrix model taking into account two recombination times. The change in width leads to a ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
The reactions between (100) GaAs and the near-noble metals Ni, Pd, and Pt have been investigated by application of high-resolution transmission electron microscopy (TEM), energy-dispersive analysis of x rays in the scanning TEM and Rutherford backscattering spectrometry. Emphasis is placed on the evolution of the phase distributions, film compositions, and interface morphologies during annealing at temperatures up to 480 /sup 0/C. The first phase in the Ni/GaAs reaction is shown to have the nominal composition Ni/sub 3/GaAs. Ternary phases of the type Pd/sub x/GaAs are also found to be the dominant products of the Pd/GaAs reaction. Conversely, only binary phases result from the Pt/GaAs reaction. These observations are used to construct isothermal sections of the M--Ga--As thin-film phase diagrams. The behavior of a thin (1--2 nm) native oxide--hydrocarbon layer during the Ni/GaAs, Pd/GaAs, and Pt/GaAs reactions is also investigated. Only the ...
1987-03-01
High-efficiency GaAs solar cells
Energy Technology Data Exchange (ETDEWEB)
An updated review of the state of the art in the development of GaAs solar cells is provided, with emphasis on AlGaAs-GaAs cells suitable for space applications. A set of theoretically derived characteristics is given for this type of solar cell. Comparison of measured performance with theory shows excellent agreement. Data on the effects of radiation damage (high-energy electrons, protons, and neutrons) is also integrated into a form useful for evaluation purposes. Techniques for fabricating (AlGa)As-GaAs solar cells in quantities large enough for practical applications are discussed and are shown to have been demonstrated. The possibility of extending these techniques to the fabrication of very thin low-weight cells for space applications is also considered. Finally, the results obtained to date in the development of GaAs solar cells for applications requiring concentrated sunlight are reviewed, for terrestrial as well as for space ...
1984-05-01
Electrical properties of inalp native oxides for metal-oxide-semiconductor device applications
Data are presented on the insulating properties and capacitance-voltage (CV) characteristics of metal-oxide-semiconductor (MOS) device-thickness (below approx. 100 nm) native oxides formed by wet thermal oxidation of thin InAlP epilayers lattice matched to GaAs. Low leakage current densities of J=1.4 x 10-9 A/cm2 and J=8.7 x 10-11 A/cm2 are observed at an applied field of 1 MV/cm for MOS capacitors fabricated with 17 nm and 48 nm oxides, respectively. TEM images show that the In-rich interfacial particles which exist in 110 nm oxides are absent in 17 nm oxide films. Quasi-static capacitance-voltage measurements of MOS capacitors fabricated on both n-type and p-type GaAs show that the InAlP oxide-GaAs interface is sufficiently free of traps to support inversion, indicating an unpinned Fermi level. These data suggest that InAlP native oxides may be a viable insulator for GaAs MOS device applications.
2004-09-01
Visualization and volumetric structures from MR images of the brain
Energy Technology Data Exchange (ETDEWEB)
Pinta is a system for segmentation and visualization of anatomical structures obtained from serial sections reconstructed from magnetic resonance imaging. The system approaches the segmentation problem by assigning each volumetric region to an anatomical structure. This is accomplished by satisfying constraints at the pixel level, slice level, and volumetric level. Each slice is represented by an attributed graph, where nodes correspond to regions and links correspond to the relations between regions. These regions are obtained by grouping pixels based on similarity and proximity. The slice level attributed graphs are then coerced to form a volumetric attributed graph, where volumetric consistency can be verified. The main novelty of our approach is in the use of the volumetric graph to ensure consistency from symbolic representations obtained from individual slices. In this fashion, the system allows errors to be made at the slice level, yet ...
1994-03-01
International Nuclear Information System (INIS)
The software package VIBA-lab1, which incorporates PIXE and RBS energy spectra simulation has now been extended to include the simulation of elemental maps from 3D structures. VIBA-lab1 allows the user to define a wide variety of experimental parameters, e.g. energy and species of incident ions, excitation and detection geometry, etc. When the relevant experimental parameters as well as target composition are defined, the program can then simulate the corresponding PIXE and RBS spectra. VIBA-LAB2 has been written with applications in nuclear microscopy in mind. A set of drag-and-drop tools has been incorporated to allow the user to define a three-dimensional sample object of mixed elemental composition. PIXE energy spectra simulations are then carried out on pixel-by-pixel basis and the corresponding intensity distributions or elemental maps can be computed. Several simulated intensity distributions for some 3D objects are demonstrated, and simulations obtained ...
1999-09-02
Tissue Heterogeneity in IMRT Dose Calculation for Lung Cancer
International Nuclear Information System (INIS)
The aim of this study was to evaluate the differences in accuracy of dose calculation between 3 commonly used algorithms, the Pencil Beam algorithm (PB), the Anisotropic Analytical Algorithm (AAA), and the Collapsed Cone Convolution Superposition (CCCS) for intensity-modulated radiation therapy (IMRT). The 2D dose distributions obtained with the 3 algorithms were compared on each CT slice pixel by pixel, using the MATLAB code (The MathWorks, Natick, MA) and the agreement was assessed with the ? function. The effect of the differences on dose-volume histograms (DVHs), tumor control, and normal tissue complication probability (TCP and NTCP) were also evaluated, and its significance was quantified by using a nonparametric test. In general PB generates regions of over-dosage both in the lung and in the tumor area. These differences are not always in DVH of the lung, although the Wilcoxon test indicated significant differences in 2 of 4 patients. ...
2011-01-01
The in-flight wavelength calibration for the Ozone Monitoring Instrument is discussed. The observed variability in the wavelength scale is two orders of magnitude larger than caused by temperature changes in the instrument. These wavelength variations are the result of rapid changes in time in the radiance levels during an individual observation in the presence of clouds or snow and ice. We have developed a data processing method to account and correct for these changes. In February 2005 this correction was implemented in the official data processing stream. We explain in detail how and how accurately this method works. Before correction, the error in the wavelength scale can be as much as a few tenths of a pixel; after correction it is mostly less than 1/100th of a pixel, which is the required preflight accuracy. This means that higher-level products such as the total column amounts of ozone, NO2, and SO2 are not significantly affected. It is ...
2006-05-01
CoSi_2 nanostructures by writing FIB ion beam synthesis
International Nuclear Information System (INIS)
A mass separated focused ion beam (FIB) is a very useful tool to fabricate nanostructures by writing implantation within an ion beam synthesis process. In these investigations the IMSA-OrsayPhysics FIB, equipped with a Co_3_6Nd_6_4 alloy liquid metal ion source, was applied. Si(100) and (111) wafers were implanted with 60 keV Co"+"+ ions in the dose range of 2 . 10"1"6 to 2 . 10"1"7 cm"-"2. Implantation parameters were investigated, like pixel dwell time, relaxation time (time between two cycles), dose rate as well as the pixel overlapping factor. The subsequent annealing was done in a two step process, namely 600 deg. C for 60 min and 1000 deg. C for 30 min in a N_2 ambient. The results obtained by SEM investigations in terms of continuous nanowire structures following the direction and interrupted CoSi_2 pattern in the direction show a clear dependence on the time scale as well as the scanning mode of the irradiation. Structure sizes as ...
2006-07-01
Energy Technology Data Exchange (ETDEWEB)
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 cases of subtle interstitial ...
1991-11-01
International Nuclear Information System (INIS)
To evaluate the diagnostic accuracy of Fuji computed radiography (FCR) in the detection of interstitial pulmonary infiltrates, FCR life-size images at a pixel size of 0.1 mm were compared with conventional radiographs taken on the same day. Seventeen radiologists assessed the radiographs and FCR images of 56 cases, including 39 cases of various interstitial lung diseases such as interstitial pneumonia, pulmonary abnormalities associated with collagen disease, sarcoidosis, multiple pulmonary metastases, diffuse panbronchiolitis and pulmonary emphysema, and 17 normal controls. All of the pulmonary abnormalities were confirmed by high resolution CT. Observer performance tests were carried out using receiver operating characteristic analysis. In 21 cases of increased pulmonary density revealed by high resolution CT, FCR was significantly superior to conventional radiographs in the detection of reticular or linear shadows. In 11 cases of subtle interstitial ...
1991-01-01
Thin film GaAs solar cells on glass substrates by epitaxial liftoff
Energy Technology Data Exchange (ETDEWEB)
In this work, we describe the fabrication and operating characteristics of GaAs/AlGaAs thin film solar cells processed by the epitaxial liftoff (ELO) technique. This technique allows the transfer of these cells onto glass substrates. The performance of the lifted-off solar cell is demonstrated by means of electrical measurements under both dark and illuminated conditions. We have also optimized the light trapping conditions in this direct-gap material. The results show that good solar absorption is possible in active layers as thin as 0.32 {mu}m. In such a thin solar cell, the open circuit voltage would be enhanced. We believe that the combination of an epitaxial liftoff thin GaAs film, and nano-texturing can lead to record breaking performance. {copyright} {ital 1997 American Institute of Physics.}
1997-02-01
Technology of GaAs metal-oxide-semiconductor solar cells
The growth of an oxide interfacial layer was recently found to increase the open-circuit voltage (OCV) and efficiency by up to 60 per cent in GaAs metal-semiconductor solar cells. Details of oxidation techniques to provide the necessary oxide thickness and chemical structure and using ozone, water-vapor-saturated oxygen, or oxygen gas discharges are described, as well as apparent crystallographic orientation effects. Preliminary results of the oxide chemistry obtained from X-ray, photoelectron spectroscopy are given. Ratios of arsenic oxide to gallium oxide of unity or less seem to be preferable. Samples with the highest OVC predominantly have As(+3) in the arsenic oxide rather than As(+5). A major difficulty at this time is a reduction in OCV by 100-200 mV when the antireflection coating is vacuum deposited.
1977-01-01
Single-event dynamics of high-performance HBTs and GaAs MESFETs
Energy Technology Data Exchange (ETDEWEB)
Picosecond charge-collection transients measured for GaAs/AlGaAs HBTs following 3.0 MeV [alpha]-particle and 620 nm picosecond laser excitation reveal charge-collection efficiencies up to twenty-eight times smaller than for GaAs MESFETs, with [approximately]90% of the charge collected within 75 ps of the ionizing event. The small charge-collection efficiency of the HBTs is a consequence of the ultrafast charge-collection dynamics in these devices. The authors show that picosecond laser excitation reproduces nicely the ion-induced transients, providing a valuable tool for the investigation of charge-collection and SEU phenomena in these devices.
1993-12-01
MOVPE growth of GaAs and InP based compounds in production reactors using TBAs and TBP
Energy Technology Data Exchange (ETDEWEB)
Today TBP and TBAs are the compounds which have the highest potential to replace the hydrides arsine and phosphine in the MOVPE process. The authors have demonstrated the entire material system Ga-In-As-P can be grown without any loss of quality using TBP and TBAs not only in one reactor, but in a complete family of reactors. These reactors range from small-scale single wafer R and D reactors to multiwafer Planetary Reactor systems. Both InP based and GaAs based materials could be grown with an excellent quality. Thus all growth processes for III-V devices--long and short wavelength lasers, LEDs, high speed transistors, etc.--can be switched to TBP and TBAs. This will drastically reduce safety hazards and lead to processes that have advantages both from the ecological and economical point of view.
1996-12-31
Interface-induced conversion of infrared to visible light at semiconductor interfaces
International Nuclear Information System (INIS)
Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al_xGa_1_-_xInP_2; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. copyright 1996 The American Physical Society.
Integrated optoelectronic materials and circuits for optical interconnects
International Nuclear Information System (INIS)
Conventional interconnect and switching technology is rapidly becoming a critical issue in the realization of systems using high speed silicon and GaAs based technologies. In recent years clock speeds and on-chip density for VLSI/VHSIC technology has made packaging these high speed chips extremely difficult. A strong case can be made for using optical interconnects for on-chip/on-wafer, chip-to-chip and board-to-board high speed communications. GaAs integrated optoelectronic circuits (IOC's) are being developed in a number of laboratories for performing Input/Output functions at all levels. In this paper integrated optoelectronic materials, electronics and optoelectronic devices are presented. IOC's are examined from the standpoint of what it takes to fabricate the devices and what performance can be expected.
International Nuclear Information System (INIS)
Pattern formation on GaAs by Ga"+ focused-ion-beam (FIB) irradiation and subsequent Cl_2 gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl_2 gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga"+ FIB-assisted Cl_2 etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga"+-ion doses.
Energy Technology Data Exchange (ETDEWEB)
Pattern formation on GaAs by Ga{sup +} focused-ion-beam (FIB) irradiation and subsequent Cl{sub 2} gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl{sub 2} gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga{sup +} FIB-assisted Cl{sub 2} etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga{sup +}-ion doses.
1990-12-15
International Nuclear Information System (INIS)
The feasibility of continuous production of gallium arsenide ribbon single crystals, by passage of a molten zone through boron-oxide encapsulated GaAs feedstock, is being investigated. Polycrystalline GaAs ribbons have been grown in graphite boats by passage of a wide zone through B2O3-encapsulated feed-stock, confined by a quartz cover plate. Failure to remove the encapsulant above its glass transition temperature, however, resulted in cracking of the ribbons on cooling to room temperature. In order to study the crucial zone melting step in isolation from the encapsulation steps of the continuous process, a constrained-zone melting apparatus has been constructed in which the boron oxide serves only as a sealant to suppress arsenic vaporization. Large grained polycrystalline samples have been produced with this apparatus.
International Nuclear Information System (INIS)
Deep level effects in GaAs MOSFET have been characterised in the ohmic channel using DLTS, low frequency excess noise and dispersion technique. An isothermal multi exponential curve fitting method has been devised and implanted into the DLTS system. Multi exponential curve fitting method used to decompose a multi exponential transient into its constituents so that the peak signature can be better characterised for the case whereas several peaks are closely spaced. Low frequency excess noise and dispersion techniques also confirm the trap in signature of the same traps observed in the DLTS measurements. (author)
Auger electron spectroscopy studies of GaAs and Si metal-semiconductor structures
The use of Auger electron spectroscopy (AES) combined with in situ sputter etching for revealing the metallurgy of the metal-semiconductor interface is presented. The physical basis, measurement techniques, and data interpretation for Auger analysis of thin-film structures are briefly reviewed. Results of a detailed study of an alloyed multilayered contact (Ni/Au-Ge) on n-type epitaxial GaAs are summarized to illustrate how electrical and metallurgical contact properties can be correlated using AES. In addition, the results of a study of the growth kinetics and chemical phase identification of palladium silicide on single-crystal Si is given, as well as the initial results of a study of aluminum-palladium silicide interaction at elevated temperature. (auth)
1975-01-01
Auger electron spectroscopy studies of GaAs and Si metal-semiconductor structures
International Nuclear Information System (INIS)
The use of Auger electron spectroscopy (AES) combined with in situ sputter etching for revealing the metallurgy of the metal-semiconductor interface is presented. The physical basis, measurement techniques, and data interpretation for Auger analysis of thin-film structures are briefly reviewed. Results of a detailed study of an alloyed multilayered contact (Ni/Au-Ge) on n-type epitaxial GaAs are summarized to illustrate how electrical and metallurgical contact properties can be correlated using AES. In addition, the results of a study of the growth kinetics and chemical phase identification of palladium silicide on single-crystal Si is given, as well as the initial results of a study of aluminum-palladium silicide interaction at elevated temperature.
Verification of lithium detector efficiency using DD neutron
International Nuclear Information System (INIS)
The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)
2005-08-01
Use of signal delay of one of detectors in two-channel radiometric flaw detector
International Nuclear Information System (INIS)
A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.
Resonant-mass detectors of gravitational radiation
International Nuclear Information System (INIS)
A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.
1987-07-01
Presentation of random process at the output of a scintillation detector
International Nuclear Information System (INIS)
(1973). USSR Ovcharenko, AM Nedavnij, OI Kapranov, BI Tomskij
The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.
1999-01-01
Application of Pd silicide in the process of silicon detectors
Energy Technology Data Exchange (ETDEWEB)
A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.
1990-04-01
radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...
Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys
Energy Technology Data Exchange (ETDEWEB)
Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)
2001-05-16
Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.
1995-08-01
Development of a small scintillation detector with an optical fiber for fast neutrons
International Nuclear Information System (INIS)
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this ...
2011-02-01
Design and fabrication of large ultra-thin PIN detector with membrane stress deviation
Energy Technology Data Exchange (ETDEWEB)
In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.
2010-09-15
Fluoroscopic tumor tracking for image-guided lung cancer radiotherapy
Energy Technology Data Exchange (ETDEWEB)
Accurate lung tumor tracking in real time is a keystone to image-guided radiotherapy of lung cancers. Existing lung tumor tracking approaches can be roughly grouped into three categories: (1) deriving tumor position from external surrogates; (2) tracking implanted fiducial markers fluoroscopically or electromagnetically; (3) fluoroscopically tracking lung tumor without implanted fiducial markers. The first approach suffers from insufficient accuracy, while the second may not be widely accepted due to the risk of pneumothorax. Previous studies in fluoroscopic markerless tracking are mainly based on template matching methods, which may fail when the tumor boundary is unclear in fluoroscopic images. In this paper we propose a novel markerless tumor tracking algorithm, which employs the correlation between the tumor position and surrogate anatomic features in the image. The positions of the surrogate features are not directly tracked; instead, we use principal component analysis of regions ...
2009-02-21
A comparison of cathode ray tube (CRT) and computed radiography (CR) diagnosis in mammography
International Nuclear Information System (INIS)
Quantitative evaluation of CRT and CR observations in indentification of malignancy using phantom and clinical data. A breast phantom and a total of 40 patients were imaged by Fuji computed radiography (FCR). The images were interpreted twice by six radiologists both on CR film (2510 x 2000 pixels x 10 bits, 0.1 mm spatial resolution) and on a CRT monitor (1568 x 1152 pixels x 10 bits, 0.1 mm pixel size with double expansion) with image processing parameters of a toutine (RN 1.0, RE 0.2), for a calcification (RN 9.0, RE 4.0) and for a mass (RN 7.0, RE 2.0). The forty clinical cases included breast diseases with calcifications, masses, and normal breasts. Two-tailed t-test was performed to analyze interpretation of simulated microcalcifications and masses in the phantom. The receiver operating characteristic (ROC) analysis was performed to evaluate clinical cases. In all interpretation studies using both breast phantom and ...
1999-11-01
Development of high resolution imaging detectors for X-ray astronomy
Energy Technology Data Exchange (ETDEWEB)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-03-01
Development of high resolution imaging detectors for X-ray astronomy
International Nuclear Information System (INIS)
High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.
1985-01-01
Core simulations using actual detector readings for a Canada deuterium uranium reactor
This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.
1991-02-01
The polarized electron gun for the SLC
International Nuclear Information System (INIS)
A new polarized electron gun for use on the SLC at SLAC has been built and tested. It is a diode gun with a laser driven GaAs photocathode. It is designed to provide short (2ns) pulses of 10 A at 160 kV at 120 Hz. The design features of the gun and results from a testing program on a new and dedicated beam line are presented. Early results from operation on the SLC will also be shown.
1992-03-24
Energy Technology Data Exchange (ETDEWEB)
The article is the second part of a review dealing with latest developments in the area of solar cell technologies and application. Physical principles, design and efficiency as well as advantages and disadvantages of GaAs- and CdS-solar cells are described. Power generation solar cell systems with voltage converters, combined solar cell/solar collector systems and thermoelectric solar systems are presented in the second part of the article.
1983-04-01
Local Structures and Interface Morphology of InGaAsN Thin Films Grown on GaAs
Energy Technology Data Exchange (ETDEWEB)
The compound semiconductor system InGaAsN exhibits many intriguing properties which are particularly useful for the development of innovative high efficiency thin film solar cells and long wavelength lasers. The bandgap in these semiconductors can be varied by controlling the content of N and In and the thin films can yet be lattice-matched to GaAs. In the present work, x-ray absorption fine structure (XAFS) and grazing incidence x-ray scattering (GIXS) techniques have been employed to probe the local environment surrounding both N and In atoms as well as the interface morphology of InGaAsN thin films epitaxially grown on GaAs. The soft x-ray XAFS results around nitrogen K-edge reveal that N is in the sp{sup 3} hybridized bonding configuration in InGaAsN and GaAsN, suggesting that N impurities most likely substitute for As sites in these two compounds. The results of In K-edge XAFS suggest a possible trend of a slightly larger coordination ...
1999-02-23
Growth and electronic properties of two-dimensional systems on (110) oriented GaAs
Energy Technology Data Exchange (ETDEWEB)
As the only non-polar plane the (110) surface has a unique role in GaAs. Together with Silicon as a dopant it is an important substrate orientation for the growth of n-type or p-type heterostructures. As a consequence, this thesis will concentrate on growth and research on that surface. In the course of this work we were able to realize two-dimensional electron systems with the highest mobilities reported so far on this orientation. Therefore, we review the necessary growth conditions and the accompanying molecular process. The two-dimensional electron systems allowed the study of a new, intriguing transport anisotropy not explained by current theory. Moreover, we were the first growing a two-dimensional hole gas on (110) GaAs with Si as dopant. For this purpose we invented a new growth modulation technique necessary to retrieve high mobility systems. In addition, we discovered and studied the metal-insulator transition in thin bulk p-type ...
2005-07-01
UK PubMed Central (United Kingdom)
An unusual S1-nuclease sensitive microsatellite (STMS) has been found in the single copy, rat polymeric immunoglobulin receptor gene (PIGR) terminal exon. In Fisher rats, elements within or beyond the...Full Text Available
1995-04-11
Energy Technology Data Exchange (ETDEWEB)
Two window layer materials, Al{sub 0.51}In{sub 0.49}P (E{sub g} = 2.3 eV) and Ga{sub 0.51}In{sub 0.49}P (E{sub g} = 1.88 eV) were compared for gas-source and solid-source MBE grown GaAs and Ga{sub 0.84}In{sub 0.16}As{sub 0.68}P{sub 0.32} (E{sub g} = 1.55 eV) solar cells. Due to the wider band-gap of Al{sub 0.51}In{sub 0.49}P, the increased spectral response was observed for both GaAs and Ga{sub 0.84}In{sub 0.16}As{sub 0.68}P{sub 0.32} material based solar cells. In the case of the GaAs cells, the short-circuit current density was observed to increase from 32.5 mA/cm{sup 2} to 34.4 mA/cm{sup 2} with the Al{sub 0.51}In{sub 0.49}P window layer at AM0. Similar improvement was observed for the Ga{sub 0.84}In{sub 0.16}As{sub 0.68}P{sub 0.32} solar cells.
1997-12-31
We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the detector never ...
2007-01-01
Segmented focal plane detector for light and heavy ions
Energy Technology Data Exchange (ETDEWEB)
A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).
1992-06-15
Energy Technology Data Exchange (ETDEWEB)
Main topic of the project was the manufacturing of highly efficient GaAs-solar cells and the fabrication of concentrator cells. During this process significant progress was made with the material preparation, the solar cell technology and the material and process characterisation. This succeeded in the following efficiencies: - GaAs solar cell made by MOVPE technology: 22.9% on 4 cm{sup 2} (AM1.5g) - GaAs solar cell made by LPE-ER process: 22.8% on 4 cm{sup 2} (AM1.5g) - GaAs concentrator solar cell made by LPE-ER process: 24.9% at C=100xAM1.5d - GaAs concentrator module with fresnel lenses: Module efficiency 20.1% (under irradiation of 793 W/m{sup 2}). Another main focus was the epitaxy of GaAs on Si substrate. Two different approaches were investigated. Together with the cooperation partner ASE, Heilbronn a selective growth technology was developed that led to a decreased crack ...
1996-10-01
UK PubMed Central (United Kingdom)
An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available
2009-12-15
Focal plane detector for reactions with medium weight projectiles
Energy Technology Data Exchange (ETDEWEB)
A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate ...
1988-12-01
Developments of heavy-ion gas detectors at LNL
Energy Technology Data Exchange (ETDEWEB)
The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.
1984-05-01
Development of a dual-detector X-ray imaging system for phase retrieval study
International Nuclear Information System (INIS)
Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...
2007-01-01
Energy Technology Data Exchange (ETDEWEB)
An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is ...
1991-03-13
Conventional detectors for a photon-photon collider
Energy Technology Data Exchange (ETDEWEB)
Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).
1995-02-01
UK PubMed Central (United Kingdom)
We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available
2010-01-01
UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors
International Nuclear Information System (INIS)
(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,
1978-06-18
The virtual fast-ion loss detector
International Nuclear Information System (INIS)
English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.
2009-09-21
Radionuclide X-ray fluorescence analysis using semiconductor detectors
International Nuclear Information System (INIS)
Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav
1979-05-01
Parameter optimization of a planar BEGe detector using Monte Carlo simulations
International Nuclear Information System (INIS)
This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.
2010-11-21
Method and system for detecting explosives
Energy Technology Data Exchange (ETDEWEB)
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
2009-03-10
GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector
We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon
2007-01-01
Explosives detection system and method
Energy Technology Data Exchange (ETDEWEB)
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
2007-12-11
Detection threshold for alpha-particles on the solid-state track detector of celluloid films
International Nuclear Information System (INIS)
(Apr 1974). Japan Murakami, Akira . Saga Univ. (Japan). Dept. of
CMS Silicon Strip Tracker Performance
In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.
2011-01-01
Advances in imaging THGEM-based detectors
International Nuclear Information System (INIS)
We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.
2007-03-01
Energy Technology Data Exchange (ETDEWEB)
A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).
1991-01-01
Pixel-based and object-oriented change detection analysis using high-resolution imagery
Energy Technology Data Exchange (ETDEWEB)
The high spatial resolution of state-of-the-art commercial satellite imagery provides a good basis for recognising and monitoring even small-scale structural changes within nuclear facilities and for planning of routine and/or challenge inspections of nuclear sites. Despite the advantages of the improved spatial resolution some problems exist that may make the interpretation of the changes more difficult: Firstly, the results of the change analysis can be very complex and unclear at a glance. Secondly, shadow formation and off-nadir images due to different sensor and solar conditions at the acquisition times can cause false signals or overlap real changes. In view to the fast-growing amount of data from different sensor types there are then some requirements of an effective change detection procedure for safeguards purposes: i. The techniques involved should possess a certain amount of robustness in terms of small misregistration errors, different atmospheric conditions at the ...
2003-05-01
Using neutron-activation detectors with fissionable nuclides
Energy Technology Data Exchange (ETDEWEB)
Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.
1986-09-01
Test of superconducting Nb/Al bilayers as particle detectors
Energy Technology Data Exchange (ETDEWEB)
Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.
2000-04-07
Position detector design using an electrostatic application of ANSYS[sup TM
Energy Technology Data Exchange (ETDEWEB)
The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.
1994-10-10
Performance of CDF calorimeter simulation for Tevatron Run II
Energy Technology Data Exchange (ETDEWEB)
The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.
2002-09-19
Energy Technology Data Exchange (ETDEWEB)
The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.
1992-06-12
Fundamental understanding of aging processes Review of the workshop results
A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.
2003-01-01
Bragg curve spectroscopy in a 4? geometry
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.
1991-02-01
Bragg curve spectroscopy in a 4. pi. geometry
Energy Technology Data Exchange (ETDEWEB)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
1991-02-01
Bragg curve spectroscopy in a 4#pi# geometry
International Nuclear Information System (INIS)
Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).
Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration
Energy Technology Data Exchange (ETDEWEB)
Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the ...
2009-07-23
British Library Electronic Table of Contents (United Kingdom)
Coal exploitation inevitably damages the natural ecological environment through large scale underground exploitation which exhausts the surrounding areas and is the cause of surface subsidence and cracks. These types of damage seriously lower the underground water table. Deterioration of the environment has certainly an impact on and limits growth of vegetation, which is a very important indicator of a healthy ecological system. Dynamically monitoring vegetation growth under coal exploitation stress by remote sensing technology provides advantages such as large scale coverage, high accuracy and abundant information. A scatter plot was built by a TM (Thematic Mapper) infrared and red bands. A detailed analysis of the distributional characteristics of vegetation pixels has been carried out. ...
2007-01-01
The VOISE Algorithm: a Versatile Tool for Automatic Segmentation of Astronomical Images
The auroras on Jupiter and Saturn can be studied with a high sensitivity and resolution by the Hubble Space Telescope (HST) ultraviolet (UV) and far-ultraviolet (FUV) Space Telescope spectrograph (STIS) and Advanced Camera for Surveys (ACS) instruments. We present results of automatic detection and segmentation of Jupiter's auroral emissions as observed by HST ACS instrument with VOronoi Image SEgmentation (VOISE). VOISE is a dynamic algorithm for partitioning the underlying pixel grid of an image into regions according to a prescribed homogeneity criterion. The algorithm consists of an iterative procedure that dynamically constructs a tessellation of the image plane based on a Voronoi Diagram, until the intensity of the underlying image within each region is classified as homogeneous. The computed tessellations allow the extraction of quantitative information about the auroral features such as mean intensity, latitudinal and longitudinal extents and length scales. ...
2009-01-01
International Nuclear Information System (INIS)
Fifteen quantitative bone scintigraphies were performed in an adolescent girl during the follow-up of a femoral osteogenic sarcoma treated by chemotherapy and massive allograft. Three hours after injection of the radiopharmaceutical (7.4 MBq/kg of 99mTc-MDP) bone activity was measured in the inferior limbs at several regions of interest centered on the hips, femurs (proximal, middle, distal) and proximal tibias. The variations of relative bone activities A/S (ratio of corresponding counting rates between two homologous regions in the affected A and in the healthy S limb) and of absolute bone activities (expressed in counts/pixel-second) are interpreted as a function of times during treatment. The quantitative results are discussed with regard to main phenomena influencing bone activity in this particular clinical case: bone growth, chemotherapy and neo-osteogenesis in allograft.
An algorithm for creating synthetic telescope images of Smoothed Particle Hydrodynamics (SPH) density fields is presented, which utilises the adaptive nature of the SPH formalism in full. The imaging process uses Monte Carlo Radiative Transfer (MCRT) methods to model the scattering and absorption of photon packets in the density field, which then exit the system and are captured on a pixelated image plane, creating a 2D image (or a 3D datacube, if the photons are also binned by their wavelength). The algorithm is implemented on the density field directly: no gridding of the field is required, allowing the density field to be described to an identical level of accuracy as the simulations that generated it. Some applications of the method to star and planet formation simulations are presented to illustrate the advantages of this new technique, and suggestions as to how this framework could support a Radiative Equilibrium algorithm are also given as an indication for ...
2010-01-01
Focused ion beam preparation of inclined planes in semiconductor materials
International Nuclear Information System (INIS)
Focused ion beam (FIB) micromachining has been used to produce inclined planes on semiconductor surfaces. A 10 keV FIB system, utilising a Ga"+ liquid metal ion source (LMIS), was employed. The ramped surfaces were prepared by digitally deflecting the ion beam in a serpentine fashion over a rectangular area and incrementing the time the beam spends at a pixel, dwell time, line by line. For the conditions used, control in micromachining the inclination of the ramps to the starting horizontal surface is of the order of 1 arc s per scan of the FIB over the area of interest. The possibility of using such surfaces prepared by FIB, along with vacuum growth techniques such as molecular beam epitaxy (MBE), for application to strain relief structures and lateral device production is discussed. (author).
Common aperture multispectral sensor flight test program
Energy Technology Data Exchange (ETDEWEB)
This paper will provide an overview of the Common Aperture Multispectral Sensor (CAMS) Hardware Demonstrator. CAMS is a linescanning sensor that simultaneously collected digital imagery over the Far-IR (8 to 12 {mu}m) and visible spectral (0.55 to 1.1 PM) spectral bands, correlated at the pixel level. CAMS was initially sponsored by the U.S. Naval Air System Commands F/A-18 program office (PMA-265). The current CAMS field tests are under the direction of Northrop-Grumman for the Defense Nuclear Agency (DNA) in support of the Follow-On Open Skies Sensor Evaluation Program (FOSEP) and are scheduled to be conducted in April 1996. 8 figs., 4 tabs.
1996-11-01
A study of reconstruction algorithms and filters for an industrial X-ray tomography system
Energy Technology Data Exchange (ETDEWEB)
Computed tomography (CT) has been incorporated in an industrial Diode-Array Digital Radiography (DADR) system. An input data size of 512 pixel points x 400 projections yielded a 400x400 output image matrix. Reconstruction algorithms used are the filtered backprojection (FBP) and the direct Fourier reconstruction (DFR). Various filters were used in the FBP reconstruction process and their effects on image quality were evaluated. A spatial resolution of 100 {mu}m was measured with a block of plates and a minimum detectable feature size in the range of 10-100 {mu}m was measured using thin wires. Industrial specimens imaged have included ceramic samples, ball bearings and integrated circuits. A number of engineering problems have been solved, such as adjustment of the X-ray source, centering of the rotator spindle in the view field and beam-hardening corrections. (orig.).
1990-12-20
International Nuclear Information System (INIS)
An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).
1996-01-01
International Nuclear Information System (INIS)
TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)
2006-11-13
Calibration of solid state nuclear track detector CR-39 for radon measurements
Energy Technology Data Exchange (ETDEWEB)
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
2007-07-01
Calibration of solid state nuclear track detector CR-39 for radon measurements
International Nuclear Information System (INIS)
Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)
A new method of imaging particle tracks in solid state nuclear track detectors
British Library Electronic Table of Contents (United Kingdom)
Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...
2010-01-01
Energy Technology Data Exchange (ETDEWEB)
A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)
1993-10-15
International Nuclear Information System (INIS)
A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).
A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements
Energy Technology Data Exchange (ETDEWEB)
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...
1991-09-01
A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements
International Nuclear Information System (INIS)
A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...
Ultrafast carrier dynamics of InGaAsN and InGaAs single quantum wells
International Nuclear Information System (INIS)
Striking differences in differential reflectance and carrier relaxation in In0.4Ga0.6As and In0.4Ga0.6As0.98N0.02 single quantum wells (SQWs) were studied using ultrafast time-resolved photoreflectance. Even with extremely thin SQW of only 60 A within 3000 A wide GaAs confining layers, negative and positive differential reflectance was observed for the excitation photon energy far above the bandgaps at 820 and 880 nm for both samples. Due to absorption by the GaAs confining layer, the peak differential reflectance pumped at 820 nm is an order of magnitude larger than that pumped at 880 nm; and it is larger for InGaAs SQWs than for InGaAsN SQWs. The shorter carrier lifetimes of these samples result from carrier-carrier scattering as pumped at both wavelengths. The longer carrier lifetime as pumped at 880 nm is due to hot phonon decay in InGaAs but may be due to stimulated emission in InGaAsN. The results reveal that the carrier dynamics is ...
2008-04-21
The potential of III-V semiconductors as terrestrial photovoltaic devices
Energy Technology Data Exchange (ETDEWEB)
III-V semiconductors, GaAs and in particular InGaP, are used in many different electronic applications, such as high power and high frequency devices, laser diodes and high brightness LED. Their direct bandgap and high reliability make them ideal candidates for the realisation of high efficiency solar cells: in the past years they have been successfully used as power sources for satellites in space, where they are able to produce electricity from sunlight with an overall efficiency of around 30%. Nowadays, the use of arsenides and phosphides as photovoltaic (PV) devices is confined only to space applications since their price is much higher than conventional Si flat panel modules, the leading PV market technology. But with the introduction of multijunction solar cells capable of operating in high concentration solar light, the area and, therefore, the cost of these cells can be reduced and will eventually find an application and market also on Earth. This article ...
2006-07-01
International Nuclear Information System (INIS)
We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ion energy of 3 keV after annealing at 400degC. (author).
Surface scientists argue about the fundamental nature of Schottky barriers, or more precisely what determines the location of the Fermi level at semiconductor surfaces and interfaces. Electrical and materials engineers worry about how to make Schottky barrier diodes and gates to field effect transistors and the control of barrier heights. There is some interesting middle ground in which the location of the surface and interface Fermi level can, for example, determine semiconductor doping characteristics during crystal growth. The authors will discuss several interesting and well known examples of doping characteristics which are still somewhat mysterious. Specifically, they address the following question: (1) why is Ge doped GaAs p type when grown from Ga melts but n type when grown from Au melts (2) why is low resistivity p type ZnSe, AlAs, and AlGaInP hard to make, and more importantly, how can the problem be fixed. In addition they describe how this concept ...
Energy Technology Data Exchange (ETDEWEB)
Room-temperature cw operation for InGaP/InGaAlP double heterostructure (DH) laser diodes on GaAs substrates was achieved for the first time. The DH wafers were grown by low-pressure metalorganic chemical vapor deposition using methyl metalorganics. A lasing wavelength of 679 nm and a threshold current of 109 mA at 24C were obtained for an inner stripe structure laser diode with a 250- m-long and 7- m stripe geometry. The laser operated at up to 51C. The characteristic temperature T0 was 87 K at around room temperature. The lowest threshold current density, 5.0 kA/cmS, was obtained with a 20- m stripe width laser diode under room-temperature pulsed operation.
1986-01-20
Positioning of self-assembled InAs quantum dots by focused ion beam implantation
International Nuclear Information System (INIS)
Self-assembled quantum dots (QDs) are envisioned as building blocks for realization of novel nanoelectronic devices, for which the site-selective growth is highly desirable. This thesis presents a successful route toward selective positioning of self-assembled InAs QDs on patterned GaAs surface by combination of in situ focused ion beam (FIB) implantation and molecular beam epitaxy (MBE) technology. First, a buffer layer of GaAs was grown by MBE before a square array of holes with a pitch of 1-2 #mu#m was fabricated by FIB implantation of Ga and In, ions respectively. Later, an in-situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by FIB. The influence of ion dose, annealing parameters and InAs amount was investigated in this work. With optimized parameters, more than 50 % single dot occupancy per hole is achieved. Furthermore, the photoluminescence spectra from ...
2006-07-01
PIXE analysis of GaAs and ZnSe
Energy Technology Data Exchange (ETDEWEB)
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the X-ray intensity ratios are not strongly affected by X-ray absorption; and therefore, the conditions necessary ...
1990-01-01
PIXE analysis of GaAs and ZnSe
International Nuclear Information System (INIS)
The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the X-ray intensity ratios are not strongly affected by X-ray absorption; and therefore, the conditions necessary for ...
1989-06-01
Energy Technology Data Exchange (ETDEWEB)
Undoped Al /SUB 0.5/ In /SUB 0.5/ P-Ga /SUB 0.5/ In /SUB 0.5/ P double heterostructure was grown on (100) GaAs by metalorganic chemical-vapor deposition for the first time. A mirror-like grown surface was obtained. Over ten-times stronger photoluminescence-intensity was gained from the sandwiched Ga /SUB 0.5/ In /SUB 0.5/ P-layer, than that from a single epitaxially-grown Ga /SUB 0.5/ In /SUB 0.5/ P-layer on (100) GaAs, indicating that high-quality Al /SUB 0.5/ In /SUB 0.5/ P-Ga /SUB 0.5/ In /SUB 0.5/ P heterointerfaces are formed in the double heterostructure. A lasing action by optical pumping with an argon ion laser was observed in the double heterostructure at 90 K. The observed stimulated emission wavelength was 6470 A.
1982-12-01
Interface-induced conversion of infrared to visible light at semiconductor interfaces
Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al{sub {ital x}}Ga{sub 1{minus}{ital x}}InP{sub 2}; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. {copyright} {ital 1996 The American Physical Society.}
1996-08-01
Generation of ammonia plasma using a helical antenna and nitridation of GaAs surface
International Nuclear Information System (INIS)
Using the ammonia (NH3) plasma generated by a helical antenna surrounded by two magnetic coils, the transition of the discharge mode from low-density plasma to high-density one was observed. At the transition, the emission intensities from the H atoms and NH radicals especially increased in the optical emission spectroscopy, while the intensities of the other emission lines also increased abruptly. The nitridation of gallium arsenide (GaAs) surface was performed using the high-density NH3 plasma, and the properties of the nitrided surface layer were compared with those nitrided by high-density N2 plasma using the same apparatus. From the spectroscopic ellipsometry measurements, the thickness of the nitrided layer was estimated to be 16-18 nm, while that by N2 was 3-4 nm. From the Ga 3d spectra, the contamination with oxygen in the nitridation layer by NH3 plasma was less than that by N2 plasma.
2003-05-15
Exploring the 2D to 3D dimensionality crossover in thin iron films
Energy Technology Data Exchange (ETDEWEB)
The temperature dependence of the spontaneous magnetization of epitaxial iron films with a thickness ranging from d=20 to 200nm has been measured. The films are grown on GaAs (100) substrates which are covered by a 150nm thick silver (100) buffer layer. For three-dimensional BCC iron it was observed already in 1929 that saturation of the spontaneous magnetization for T->0 is perfectly described by a T{sup 2} power law. On the other hand, for thin two-dimensional (2D) iron films a T{sup 3/2} law has been established in many recent experimental investigations. In our iron films grown on diamagnetic silver, this dimensionality change occurs at a thickness between d=100 and 200nm. Comparison of the here-observed T{sup 3/2} coefficients with those on iron films grown on paramagnetic tungsten (110) shows that the 2D interactions are {approx}20 times larger in the films on tungsten. Recent results on Fe films which are grown directly on GaAs ...
2006-05-15
Energy Technology Data Exchange (ETDEWEB)
To attain reproducible and stable contacts to compound semiconductor devices, it is necessary to achieve thermodynamically stable phases after the reaction of metals with the compound semiconductor. In this study, the final phases produced by the reactions between GaAs and thin metal films of Co, Rh, Ir, Ni, Pd, and Pt have been investigated. They are identified as MGa for M = Co, Rh, Ni, Pd, and Pt, monoarsenides of Co and Ni, diarsenides of Rh, Ir, Pd, and Pt, and Ir/sub 3/Ga/sub 5/. These phases, if deposited directly onto GaAs, will produce thermally stable contacts. In addition to the identification of these stable phases, analyses of the products of thin-film M/GaAs reactions by transmission electron microscopy, x-ray diffraction, and Rutherford backscattering spectrometry reveal the distribution, grain size, and crystallographic texture of these end phases. Trends in these observations across the six metal/GaAs reactions studied are ...
1987-09-01
Al[sub 0. 3]Ga[sub 0. 7]As/GaAs heterojunction tunnel diode for tandem solar cell applications
Energy Technology Data Exchange (ETDEWEB)
A p[sup +]-Al[sub 0.3]Ga[sub 0.7]As/n[sup +]-GaAs heterojunction tunnel diode was fabricated using Atomic Layer Epitaxy (ALE) growth technique. Background carbon doping of [similar to]10[sup 20] cm[sup [minus]3] was achieved in the p-side of the diode by optimizing growth conditions such as V/III ratio, exposure times to reactant gases, and growth temperature. In the n-side of the diode GaAs was doped with silane and doping concentrations as high as 7[times]10[sup 18] cm[sup [minus]3] were also achieved. The dopants are chosen to satisfy the high levels and low diffusion requirements. The diode can be used to interconnect the high and low band-gap cells in the AlGaAs/GaAs cascade solar cell structure. The reactor used in this investigation is a commercial MOCVD system which has been specially modified for dual operation of ALE and MOCVD growth modes.
1994-06-30
Using focused ion beam damage patterns to photoelectrochemically etch features in III-V materials
Energy Technology Data Exchange (ETDEWEB)
A method of patterning n-type GaAs, InP, InGaAs, and InGaAsP by photoelectrochemical (PEC) etching in conjunction with a submicron focused ion beam (FIB) at low dose is described. The ion beam is used to produce damage in a desired pattern in the material. Subsequent PEC etching of the material reveals the ion induced features in relief. The procedure is highly sensitive, requiring a dose of only 5 x 10/sup 9/ ions/cm/sup 2/ for the differential etch to become apparent. The sensitivity allows rapid pattern generation in our FIB system.
1986-03-10
State-of-the-art in photovoltaic research and application (except for use in concentrators)
Energy Technology Data Exchange (ETDEWEB)
A review is given of the state-of-the-art of single and polycrystalline solar cells, which includes a short theoretical review, laboratory achievements, and production methods. The Si single and polycrystalline cell and the amorphous Si cell are described, including material preparation, crystal and sheet growth, and cell and panel production. Promising second generation thin film solar cells including GaAs, CdS(CuInSe/sub 2/), and CdTe are briefly described. Economical aspects are discussed.
1987-01-01
Microcomputers: usage, methods and structures
International Nuclear Information System (INIS)
The use of workstations, controllers or embedded systems and their applications have become much more relevant than previously. PC-based systems, a cooker programmer, applications of, for example, Prolog machines, Unix and Ada papers, Robotics and Automation are typical examples of this. The three keynote addresses of this symposium have as their subjects the most spectacular microcomputer fields and are presented by leading experts. The papers presented cover most of the traditional interests of Euromicro. Special emphasis is given to contributions on the use of workstations and personal computers, on RISC and GaAs and on transputers.
Local Heine-Abarenkov model potential for III-V and II-VI covalent compounds
Energy Technology Data Exchange (ETDEWEB)
A local Heine-Abarenkov model potential is proposed for zinc blende-type crystals. The potential parameters are determined by satisfying the zero pressure condition and the first zero of the empirical pseudopotential interpolated from band calculations. Two sets of parameters are presented for thirteen tetrahedral compounds such as AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, InSb, ZnS, ZnSe, ZnTe, and CdTe.
1983-10-01
Energy Technology Data Exchange (ETDEWEB)
This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...
1985-03-01
Large area, low capacitance Si(Li) detectors for high rate x-ray applications
Energy Technology Data Exchange (ETDEWEB)
Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...
1992-10-01
Energy Technology Data Exchange (ETDEWEB)
We have investigated the generation and propagation of misfit dislocations in strained In/sub y/Ga/sub 1-//sub y/As/GaAs multiquantum wells grown by molecular-beam epitaxy, with cross-sectional transmission electron microscopy. The samples are of excellent optical quality, with multiquantum wells having well widths of 100 A, being characterized by excitonic linewidths and Stokes shifts of 1.5--2.5 and 1--2 meV, respectively. We have examined the growth of 2-..mu..m-thick multiquantum-well samples grown either directly on GaAs, or with an intermediate composition buffer layer, and for the cases of small (y = 0.07) and large (y = 0.16) misfits. It is seen that for the case of quantum wells with small misfit, grown directly on GaAs, metastable growth can be achieved. This is confirmed by low-temperature absorption measurements and from transmission electron microscopy experiments performed both before and after post-growth thermal annealing. In ...
1989-05-01
In an earlier paper (Phys. Rev. Lett. 66, 41 (1991)), we calculated both the dielectric constant ({epsilon}{sub {infinity}}) and the nonlinear optical susceptibilities for second-harmonic generation ({chi}{sup (2)}) in the static limit for AlP, AlAs, GaP, and GaAs in the local-density approximation with and without a self-energy correction in the form of a scissors operator,'' including local-field effects. In this paper, we expand our presentation of this calculation. Agreement with experiment to within 15% for the nonlinear susceptibility is demonstrated where experiments are available (GaP and GaAs); the dielectric constants are in no worse than 4% agreement with experiment. The virtual hole'' contributions are reformulated to avoid large numerical cancellations in the case of near degeneracies. The virtual electron'' terms dominate over the virtual hole'' terms ...
1991-12-15
New materials for future generations of III-V solar cells
Energy Technology Data Exchange (ETDEWEB)
Three- and four-junction III-V devices are proposed for ultrahigh-efficiency solar cells using a new 1-eV material lattice-matched to GaAs, namely, GaInNAs. We demonstrate working prototypes of a GaInNAs-based solar cell lattice-matched to GaAs with photoresponse down to 1 eV. Under the AM1.5 direct spectrum with all the light higher in energy than the GaAs band gap filtered out, the prototypes grown with base doping of about 10{sup 17}&hthinsp;cm{sup {minus}3} have open-circuit voltages ranging from 0.35 to 0.44 V, short-circuit current densities of 1.8 mA/cm{sup 2}, and fill factors from 61{percent} to 66{percent}. To improve on the current record-efficiency tandem GaInP/GaAs solar cell by adding a GaInNAs junction, the short-circuit current density of this 1-eV cell must be significantly increased. Because these low short-circuit current densities are due to short diffusion lengths, we have demonstrated a ...
1999-03-01
Energy Technology Data Exchange (ETDEWEB)
This thesis details the first direct ultrafast measurements of the dynamic thermal expansion of a surface and the temperature dependent surface thermal diffusivity using a two-color reflection transient grating technique. Studies were performed on p-type, n-type, and undoped GaAs(100) samples over a wide range of temperatures. By utilizing a 90 fs ultraviolet probe with visible excitation beams, the effects of interband saturation and carrier dynamics become negligible; thus lattice expansion due to heating and subsequent contraction caused by cooling provided the dominant influence on the probe. At room temperature a rise due to thermal expansion was observed, corresponding to a maximum net displacement of {approximately} 1 {Angstrom} at 32 ps. The diffracted signal was composed of two components, thermal expansion of the surface and heat flow away from the surface, thus allowing a determination of the rate of expansion as well as the surface thermal diffusivity, ...
1992-04-01
Statistical description and estimation of ocean drift ice environments
Energy Technology Data Exchange (ETDEWEB)
Part I of this thesis is on long-term iceberg collision-risk assessment methods for fixed offshore structures. Estimates for the long-term probability that an iceberg will hit a fixed offshore structure are based on estimates of the total volume of produced iceberg, a model for the size distribution of icebergs and a description of how iceberg trajectories ``fill`` the plane (the ocean`s surface). Part II of the thesis discusses methods for analysis of low resolution data in the sense that the size of the area covered by each pixel is not small compared to the dominating floes. Still, this type of data can provide estimates of the ice extent (and hence the ice edge) and ice concentration. The estimates of the ice edge (at least) seem to be physically significant in the sense that ``in some way`` they can reflect ice drift in an image time sequence. A priori this is far from obvious. A central idea is that the ``ice edge`` is close to a transition zone between two ...
1991-04-01
Preliminary study of metabolic radiotherapy with {sup 188}Re via small animal imaging
Energy Technology Data Exchange (ETDEWEB)
{sup 188}Re is a {beta}{sup -} (Emax=2.12 MeV) and {gamma} (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, {sup 99m}Tc, molecules of hyaluronic acid (HA) have been labelled with {sup 188}Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm{sup 3} pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of {sup 188}Re and with C57 black mice injected with the {sup 188}Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal ...
2006-01-15
ARM AND INTERARM STAR FORMATION IN SPIRAL GALAXIES
International Nuclear Information System (INIS)
We investigate the relationship between spiral arms and star formation in the grand-design spirals NGC 5194 and NGC 628 and in the flocculent spiral NGC 6946. Filtered maps of near-IR (3.6 #mu#m) emission allow us to identify 'arm regions' that should correspond to regions of stellar mass density enhancements. The two grand-design spirals show a clear two-armed structure, while NGC 6946 is more complex. We examine these arm and interarm regions, looking at maps that trace recent star formation-far-ultraviolet (GALEX NGS) and 24 #mu#m emission (Spitzer SINGS)-and cold gas-CO (HERACLES) and H I (THINGS). We find the star formation tracers and CO more concentrated in the spiral arms than the stellar 3.6 #mu#m flux. If we define the spiral arms as the 25% highest pixels in the filtered 3.6 #mu#m images, we find that the majority (60%) of star formation tracers occur in the interarm regions; this result persists qualitatively even when considering the potential impact ...
2010-12-10
Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector
Energy Technology Data Exchange (ETDEWEB)
The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with ...
2006-07-01
High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics ...
2000-01-01
Physics of the {sup 252}Cf-source-driven noise analysis measurement
Energy Technology Data Exchange (ETDEWEB)
The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...
1997-02-01
Electronics for the Si detectors in APEX
Energy Technology Data Exchange (ETDEWEB)
APEX (ATLAS Positron EXperiment), a collaborative effort of ANL, FSU, MSU/NSCL, Princeton, Queen`s, Rochester, Washington and Yale, is an experiment to study positron and electron production in very heavy ion collisions. The electrons and positrons are detected with two detector arrays, each consisting of 216 1 mm thick Si PIN diodes, and their energy and time-of-flight are measured. The number of detectors and limited space made it necessary to develop a system that could efficiently process and transfer signals from the detectors to the charge sensing ADC`s and data readout electronics as well as monitor the condition of the detectors. The discussion will cover the electronics designed for the Si detectors, including the charge amplifier, ``Mother board`` for the charge amplifiers, 8 channel Shaper, 16 channel Constant Fraction Discriminator (CFD), 16 channel Peak-to-FERA (PTF) ...
1994-07-01
Characterization of 3D thermal neutron semiconductor detectors
International Nuclear Information System (INIS)
Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the electrical properties ...
2007-06-11
The hunt for ?13 at the Daya Bay nuclear power plant
International Nuclear Information System (INIS)
The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.
2010-03-30
The cross-coupled interferometer for gravitational wave detection
International Nuclear Information System (INIS)
The cross-coupled interferometer is a new design for interferometric gravitational wave detectors. Similar to the baseline gravitational wave detectors proposed for Advanced LIGO, it uses long-arm cavities in which the signal is generated. The signal fields are then extracted from the arm cavities with an additional cavity behind the long-arm cavities. The tuning of this signal extraction cavity and the parallel tuning of the signal recycling mirror can be used to optimize the peak frequency and the bandwidth of the detector independently. If we replace the signal recycling mirror by a small cavity, it is possible to amplify signals in two different frequency bands.
2002-04-07
International Nuclear Information System (INIS)
We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.
2004-03-07
International Nuclear Information System (INIS)
The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.
Studies of a Poenitz-type black neutron detector as a neutron flux monitor
Energy Technology Data Exchange (ETDEWEB)
A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).
1997-04-01
Silicon Detector Letter of Intent
Energy Technology Data Exchange (ETDEWEB)
This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.
2010-05-26
Nuclear borehole logging using lithium detector assemblies
International Nuclear Information System (INIS)
A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).
1991-11-01
Energy Technology Data Exchange (ETDEWEB)
Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.
1993-12-01
A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection
Energy Technology Data Exchange (ETDEWEB)
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
1991-05-01
A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection
International Nuclear Information System (INIS)
A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).
A PDA-Based ECG Beat Detector for Home Cardiac Care.
Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192
2005-01-01
View Record - NASA Jet Propulsion Laboratory
Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...
The mass dependence of the signal peak height of a Bragg-curve ionization chamber
International Nuclear Information System (INIS)
The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).
The CDF intermediate silicon layers detector
Energy Technology Data Exchange (ETDEWEB)
The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.
1999-11-01
The Brazilian Bragg curve detector built for AMS studies
Energy Technology Data Exchange (ETDEWEB)
A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.
2000-10-01
Studies of relativistic heavy ion collisions at the AGS (Experiment 814)
Energy Technology Data Exchange (ETDEWEB)
This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)
1990-01-01
The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. ...
2001-01-01
Space Images - NASA Jet Propulsion Laboratory
Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...
Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information
International Nuclear Information System (INIS)
The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)
2010-11-01
Radon concentration measurements by means of nuclear tracks detector with image analysis
International Nuclear Information System (INIS)
English 1998 p. 124 Poland Antanasijevic, R. Vukovic, J. Novakovic, V. Tasic,
1998-09-15
Photoconductive ultraviolet detectors based on ZnO films
British Library Electronic Table of Contents (United Kingdom)
Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...
2006-01-01
Particle identification for heavy ions in a time-of-flight spectrometer
Energy Technology Data Exchange (ETDEWEB)
A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.
1982-05-01
PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.
Energy Technology Data Exchange (ETDEWEB)
We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te inclusions within ...
2006-10-29
International Nuclear Information System (INIS)
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
2009-01-01
British Library Electronic Table of Contents (United Kingdom)
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
2009-01-01
Optimal detector deployment for the CANDU-600 pressurized heavy water reactor
An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through ...
1992-01-01
Mass dependence of the signal peak height of a Bragg-curve ionization chamber
Energy Technology Data Exchange (ETDEWEB)
The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.
1985-01-01
Linewidth-broadened Fabry-Perot cavities within future gravitational wave detectors
International Nuclear Information System (INIS)
The bandwidth of LIGO-like terrestrial interferometric gravitational wave detectors is set by the pole of the Fabry-Perot cavities within the arms of the Michelson interferometer. This constraint arises because the gain of gravitational wave-induced signal sidebands is limited to frequencies within the linewidth of the cavities. The nature of standard Fabry-Perot cavities is such that one cannot independently adjust for increased gain without suffering a loss of bandwidth. If these quantities could be decoupled, the resulting improvement in bandwidth may lead to viable high frequency detectors. A pair of anti-parallel diffraction gratings within a Fabry-Perot cavity can increase the bandwidth of a LIGO-scale detector by a factor of #approx#1000.
2004-03-07
LAMBDA - IRAS Faint Source Survey Plates - LAMBDA - NASA
Apr 18, 2008 ... The FSS was produced by point-source filtering the individual detector data ... a 1-sigma noise map; and a coverage map giving the count of ...
Intercomparison of Retrospective Radon Detectors
Energy Technology Data Exchange (ETDEWEB)
We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated measurements using two ...
1998-11-01
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in ...
2006-11-13
Development of a new #gamma#-ray detector for PEM applications
International Nuclear Information System (INIS)
The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)
2007-05-01
Energy Technology Data Exchange (ETDEWEB)
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...
2010-10-15
International Nuclear Information System (INIS)
Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...
2010-10-01
Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies
International Nuclear Information System (INIS)
Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.
2008-08-25
DESIGN, IMPLEMENTATION AND TESTING OF ... - LAMBDA - NASA
FIG. 4. Power Spectral Density of the MAP W11 radiometer. The red and black traces are the power spectral density measurements of the two detectors on the ...
Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid
In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.
1993-01-01
Energy Technology Data Exchange (ETDEWEB)
Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).
1993-12-31
International Nuclear Information System (INIS)
Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).
Change of the DKPS-100 semiconductor detector properties under 3.2 MeV alpha particle irradiation
International Nuclear Information System (INIS)
Russian 1977. p. 582. USSR Antropov, AE Fedoseeva, OP Milovanov,
International Nuclear Information System (INIS)
Polish 2001 p. 105 Poland Bogacz, J. Budzanowski, M. Mazur, J. Swakon,
2001-09-10
Annihilation of antiprotons in light nuclei
CR-39 detectors have been exposed to a 5.9-MeV antiproton beam using the low energy antiproton ring (LEAR) facility at CERN. At this energy, tracks of antiprotons appear in a CR-39 detector after 135 min of etching in 6 M NaOH at 70C. Fluence of the antiproton beam has been determined using track density. We have also found tracks in the etched CR-39 detector at different depths (250-500 mum). These tracks have resulted from the annihilation of antiprotons with the constituents (H, C and O) of the CR-39 detector. The goal of the experiment is to develop a simple and low-cost method to study properties of antiparticles and those formed after annihilation of these particles with the target matter.
2006-01-01
AeroSpace Information for a Changing World - NASA Technical ...
Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...
A real-time neutron dosimeter for high energy neutrons with an Si surface barrier detector
International Nuclear Information System (INIS)
1982. p. 173-175. Israel Eisen, Y. Engler, G. Ovadia, E. Shamai, Y. Israel
1982-12-14
A Quantum-Enhanced Prototype Gravitational-Wave Detector
The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point fluctuations of the electromagnetic field, which constrain the precision with which optical signals can be measured. In the world of precision measurement, laser-interferometric gravitational wave (GW) detectors are the most sensitive position meters ever operated, capable of measuring distance changes on the order of 10^-18 m RMS over kilometer separations caused by GWs from astronomical sources. The sensitivity of currently operational and future GW detectors is limited by quantum optical noise. Here we demonstrate a 44% improvement in displacement sensitivity of a prototype GW detector with suspended quasi-free mirrors at frequencies where the sensitivity is shot-noise-limited, by ...
2008-01-01
8 - NASA Technical Report Server (NTRS)
feature similar to the face detection in Intel's OpenCV library, implement it in Matlab code, and test the performance of the new ROI detector against the ...
Energy Technology Data Exchange (ETDEWEB)
With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga{sup +} focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned features.
2005-04-01
International Nuclear Information System (INIS)
With the aim of studying the magnetic properties of reduced-dimensionality magnetic systems we have patterned 250 nm- and 500 nm-size square elements on Fe/NiO layers by 30 keV Ga"+ focused ion beam (FIB) milling, varying beam current and pixel dwell time. By high resolution scanning electron microscope (SEM) imaging and atomic force microscopy (AFM) analysis we found that island size decreases from the nominal value by increasing the beam current and features sharpness improves on increasing the dwell time. The top surface of the isolated features has a pronounced edge bending which may be as high as 9 nm with respect to the flat inner area of the island and decreases as dwell time grows. By varying the ion fluence we found that such a shape is related to a surface swelling effect occurring at low ion fluence in the irradiated areas. The swelling-related damage at the edges is expected to influence the magnetic properties of the patterned features.
2005-04-01
Short wave length and high qualification of free-electron laser
International Nuclear Information System (INIS)
The oscillation experiment of free-electron laser (FEL) was carried at the wave length 488 nm. The space and time properties and power of FEL were investigated. The typical macropulse structure indicated the time interval 20 ms and the pulse width 2 to 3 ms. About 1 ns was necessary to build up FEL. The space distribution of FEL showed beautiful TEM_0_0 mode, TEM_0_1 and TEM_0_2 mode. On the basis of data, 39 #mu#W average power was calculated at 2.9 mA accumulated current per bunch by integrating each response of pixel of CCD camera. The peak power was 1.2 W. In the oscillator, FEL power was average 1.2 W, peak 38 kW. On the electron beam, the stability of head tail was controlled by 6-pole-Quadrupole-6-pole (SQS) system made by an experimental basis. We succeeded the single set test, setting up single set in the ring. The characteristic properties of electron beam evaporation mirror of photo oscillator were studied and then new type photo oscillator to obtain ...
1998-02-01
On-line video image processing system for real-time neutron radiography
Energy Technology Data Exchange (ETDEWEB)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 distinct colors on a RGB ...
1983-09-15
Lymph node staging in cervical carcinoma: Results of high resolution MRT with phased-array coil
International Nuclear Information System (INIS)
Purpose: To determine the diagnostic value of high resolution MR imaging with a circularly polarised (c.p.) body phased-array coil for the staging of pelvic lymph nodes in cervical carcinoma. Material and methods: 42 patients with histologically proven carcinoma of the cervix were studied on a 1.5 T scanner by using a c.p. body phased-array coil. The imaging protocol included T_2-weighted turbo-spin-echo (TSE) and T_1-weighted spin-echo sequences pre and post IV application of Gd-DTPA; slice thickness was 5-7 mm and pixel size 0.53 mm"2. Lymph nodes with a diameter of #>=#8 mm were considered to have metastatic involvement. MR imaging results were compared with histopathologic findings. Results: MR imaging showed enlarged lymph nodes (#>=# 8 mm) in 16 of 18 patients with histologic proof of lymph node metastases (sensitivity 89%). In 22 of 24 cases MR findings were true negative (specificity 92%). Diagnostic accuracy was 91%. Conclusion: High-resolution MR ...
Improvement of FCR-linear tomography using digital image processing
Energy Technology Data Exchange (ETDEWEB)
In order to improve the image quality of linear tomography performed with the Fuji Computed Radiography (FCR) system, we have examined one-dimensional unsharp mask filtering to reduce blur formed in the direction of tomographic swing. We determined a mask size and a weighting factor of the image processing suitable to obtain a quality tomogram. The mask size of 41 x 1 pixels for a 14 x 14'' imaging plate, which modifies the original image date and results in demonstrating a peak frequency at 0.2 cycles/mm for spatial frequency spectrum, is superior in showing fine vessel structures and morphological features of pathology in the lung fields. An additional spatial frequency filtration in the direction perpendicular to the tomographic movement reduces the blur and clearly demonstrates object contours running parallel to the tube movement. However, the additional filtration increases the appearance of noise on the processed image and offsets the ...
1994-02-01
Energy Technology Data Exchange (ETDEWEB)
A computer-aided detection (CAD) system was evaluated for its ability to detect microcalcifications and masses on images obtained with a digital phase-contrast mammography (PCM) system, a system characterised by the sharp images provided by phase contrast and by the high resolution of 25-{mu}m-pixel mammograms. Fifty abnormal and 50 normal mammograms were collected from about 3,500 mammograms and printed on film for reading on a light box. Seven qualified radiologists participated in an observer study based on receiver operating characteristic (ROC) analysis. The average of the areas under ROC curve (AUC) values for the ROC analysis with and without CAD were 0.927 and 0.897 respectively (P = 0.015). The AUC values improved from 0.840 to 0.888 for microcalcifications (P = 0.034) and from 0.947 to 0.962 for masses (P = 0.025) respectively. The application of CAD to the PCM system is a promising approach for the detection of breast cancer in its early stages. (orig.)
2009-12-15
Energy Technology Data Exchange (ETDEWEB)
Largest coal mine fires in the world are reported from Jharia coalfield in Dhanbad district, Bihar State of India. In this paper we report the utility of day and night time Thematic Mapper thermal IR data (120 m x 120 m) for detecting and monitoring mine fires in Jharia. For this purpose, seven sets of TM data acquired between 1985 to 1995 have been analysed. Data processing methods include geometric and radiometric corrections, conversion of DN values to at-satellite temperatures and colour coding of temperature images. The pixel-integrated temperatures of 50{degrees}C and above have been classified as mine fires and achieved an accuracy of 81.2%. Also, assessed year wise, colliery-wise and geological formation-wise mine fire distribution in this area. Although TM thermal data is of coarser resolution, it enabled detection of mine fires mainly because of the large areal extent and high temperature range of mine fires. It is possible to detect mine fires of 70 m ...
1996-08-01
An on-line video image processing system for real-time neutron radiography
International Nuclear Information System (INIS)
The neutron radiography system installed at the E-2 experimental hole of the KUR (Kyoto University Reactor) has been used for some NDT applications in the nuclear field. The on-line video image processing system of this facility is introduced in this paper. A 0.5 mm resolution in images was obtained by using a super high quality TV camera developed for X-radiography viewing a NE-426 neutron-sensitive scintillator. The image of the NE-426 on a CRT can be observed directly and visually, thus many test samples can be sequentially observed when necessary for industrial purposes. The video image signals from the TV camera are digitized, with a 33 ms delay, through a video A/D converter (ADC) and can be stored in the image buffer (32 KB DRAM) of a microcomputer (Z-80) system. The digitized pictures are taken with 16 levels of gray scale and resolved to 240 x 256 picture elements (pixels) on a monochrome CRT, with the capability also to display 16 distinct colors on a RGB ...
1983-09-01
A Global Framework for Monitoring Phenological Responses to Climate Change
Energy Technology Data Exchange (ETDEWEB)
Remote sensing of vegetation phenology is an important method with which to monitor terrestrial responses to climate change, but most approaches include signals from multiple forcings, such as mixed phenological signals from multiple biomes, urbanization, political changes, shifts in agricultural practices, and disturbances. Consequently, it is difficult to extract a clear signal from the usually assumed forcing: climate change. Here, using global 8 km 1982 to 1999 Normalized Difference Vegetation Index (NDVI) data and an eight-element monthly climatology, we identified pixels whose wavelet power spectrum was consistently dominated by annual cycles and then created phenologically and climatically self-similar clusters, which we term phenoregions. We then ranked and screened each phenoregion as a function of landcover homogeneity and consistency, evidence of human impacts, and political diversity. Remaining phenoregions represented areas with a minimized probability ...
2005-02-01
Energy Technology Data Exchange (ETDEWEB)
The theoretical performance of ideal single- and multijunction cells are compared at 100xconcentration under a range of cloudless-sky conditions. The sensitivities of device performance to cell temperature and spectral variations are shown to depend on the number of junctions (one, two or three), the way in which the junctions are connected (series, parallel or independent), and the band gaps of the devices. The average performances of all of the multijunction devices surpass that of a single-junction GaAs device, but the inconsistency in performance of some of the multijunction devices is significant for large variations in cell temperature and incident spectrum. The choice of band gap and connection scheme is more important than the number of junctions in determining the consistency of device performance. (orig.).
1991-05-01
Temperature dependence of threshold current of injection lasers for short pulse excitation
Energy Technology Data Exchange (ETDEWEB)
We report measurements of the temperature dependence of the threshold current of GaAs, 1.3-..mu..m InGaAsP, and 1.5-..mu..m InGaAsP double heterostructure lasers using short electrical pulses. T/sub 0/approx.200 K is observed for all the lasers. These high T/sub 0/ values show that the carrier density at threshold does not increase rapidly with increasing temperature in any of the lasers studied and thus the observed low cw T/sub 0/ of InGaAsP lasers is primarily due to a decrease of the carrier lifetime at threshold with increasing temperature.
1984-05-15
Status of nonsilicon photovoltaic solar cell research
Energy Technology Data Exchange (ETDEWEB)
The current status of non-silicon photovoltaic solar cells is discussed including the identification of current technical and economic issues and future research directions for potential high efficiency low cost technologies. This review covers such advanced materials as CdS/Cu/sub 2/S, CdS/CuInSe/sub 2/, and GaAs homojunction and heterojunction devices; such emerging materials as InP, Zn/sub 3/P/sub 2/ and CdTe; and liquid junction electrochemical photovoltaic cells. An attempt is made to compare the current relative status of these various technologies and to indicate their near term potential where possible. 105 refs.
1980-01-01
Energy Technology Data Exchange (ETDEWEB)
Efforts concentrated on updating of the Rockwell reference concept, definition of new system options, studies of special emphasis topics, further definition of the transportation system, and further program definition. The Rockwell reference satellite concept has a gallium arsenide (GaAs) solar cell array having flat concentrators with an effective concentration ratio of 1.83at end of life. Alternatives to this concept includes solid state power amplifiers or magnetrons for dc/RF conversion and multibandgap solar cells for solar to dc energy conversion. Two solid state concepts were studied. It was determined that the magnetron approach was the lowest mass and cost system.
1981-03-01
Point defects in dilute nitride III-N-As and III-N-P
International Nuclear Information System (INIS)
We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.
2006-04-01
Observation of strain-enhanced electron-spin polarization in photoemission from InGaAs
International Nuclear Information System (INIS)
Electron-spin polarization in excess of 70% has been observed in photoemission from a 0.1-#mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x#approx#0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single-band transition.
Energy Technology Data Exchange (ETDEWEB)
This report describes progress during the first year of a three-year project. The objective of the research is to examine new design approaches for achieving very high conversion efficiencies. The program is divided into two areas. The first centers on exploring new thin-film approaches specifically designed for III-V semiconductors. The second area centers on exploring design approaches for achieving high conversion efficiencies without requiring extremely high quality material. Research activities consisted of an experimental study of minority carrier recombination in n-type, metal-organic chemical vapor deposition (MOCVD)-deposited GaAs, an assessment of the minority carrier lifetimes in n-GaAs grown by molecular beam epitaxy, and developing a high-efficiency cell fabrication process.
1993-01-01
New III-V cell design approaches for very high efficiency
Energy Technology Data Exchange (ETDEWEB)
This report describes progress during the first year of a three-year project. The objective of the research is to examine new design approaches for achieving very high conversion efficiencies. The program is divided into two areas. The first centers on exploring new thin-film approaches specifically designed for III-V semiconductors. The second area centers on exploring design approaches for achieving high conversion efficiencies without requiring extremely high quality material. Research activities consisted of an experimental study of minority carrier recombination in n-type, metal-organic chemical vapor deposition (MOCVD)-deposited GaAs, an assessment of the minority carrier lifetimes in n-GaAs grown by molecular beam epitaxy, and developing a high-efficiency cell fabrication process.
1993-01-01
International Nuclear Information System (INIS)
The highest equilibrium free-carrier doping concentration possible in a given material is limited by the ''pinning energy'' which shows a remarkable universal alignment in each class of semiconductors. Our first-principles total energy calculations reveal that equilibrium n -type doping is ultimately limited by the spontaneous formation of close-shell acceptor defects: the 3- -charged cation vacancy in AlN, GaN, InP, and GaAs and the 1- -charged DX center in AlAs, AlP, and GaP. This explains the alignment of the pinning energies and predicts the maximum equilibrium doping levels in different materials. (c) 2000 The American Physical Society
2000-02-07
Materials aspects of multijunction solar cells
Energy Technology Data Exchange (ETDEWEB)
Atomic layer epitaxy (ALE) was used to grow several components of the cascade solar cell structure in the AlGaAs/GaAs system. An ALE reactor was constructed for multiwafer growth with a growth rate of 0.6 {mu}m h{sup -1}. Device quality GaAs and Al{sub x}Ga{sub 1-x}As films were grown with p-type background carbon doping in the ranges 10{sup 16}-10{sup 19} cm{sup -3} and 10{sup 16}-10{sup 20} cm{sup -3} respectively. N-type films were achieved by SiH{sub 4} doping, producing carrier concentrations in the range 10{sup 16}-10{sup 18} cm{sup -3}. In addition, the potential applications of the ALE technique in the photovoltaic field are discussed. (orig.).
1991-05-01
Focused ion beam implantation induced site-selective growth of InAs quantum dots
International Nuclear Information System (INIS)
The site-selective growth of InAs quantum dots (QDs) by a combined focused ion beam (FIB) and molecular beam epitaxy (MBE) process has been demonstrated. An array of FIB modified spots on MBE grown GaAs was fabricated. Thereafter, an in situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by the FIB. The influences of ion dose, annealing parameters, and InAs amount were investigated. With optimized parameters, the authors observe more than 50% single dot occupancy per holes. Photoluminescence spectra confirm the good optical quality of the QDs.
2007-09-17
International Nuclear Information System (INIS)
The intensity of superstructure reflections and associated diffuse scattering from In_0_._5Ga_0_._5P and In_0_._5Al_0_._5P epitaxic layers grown on (001) GaAs substrates was mapped in reciprocal space. The Warren-Cowley short-range-order parameters were obtained through the usual process for evaluating Fourier coefficients. Varying values for the correlation length in different directions indicate how group III atoms stack up in ordered states. The resultant structure with long-range order confirms the hypothesis made on the basis of electron diffraction and high-resolution transmission electron microscopy studies. (orig.).
British Library Electronic Table of Contents (United Kingdom)
Within the framework of the effective-mass approximation, using a variational method, we have calculated the effect of intense laser radiation on the binding energy of the shallow-donor impurities in a Ga1- x In x N y As1- y /GaAs single quantum well for different nitrogen and indium mole concentrations. Our numerical results show that the binding energy strongly depends on the laser intensity and frequency (via the laser dressing parameter) and it also depends on the nitrogen and indium concentrations. Impurity binding energy under intense laser fields can be tuned by changing the nitrogen and indium mole fraction.
2011-01-01
Energy Technology Data Exchange (ETDEWEB)
In this paper, we discuss various aspects of the development of an inverted-grown AlGaAs/GaAs cascade solar cell incorporating a patterned germanium tunnel junction. Topics include the development of the Al{sub 0.37}Ga{sub 0.63}As top cell, the growth of the GaAs bottom cell over the patterned germanium tunnel junction, and a technique for selective removal of thin AlGaAs/GaAs heterostructures after lattice-matched growth on germanium substrates. The problems to be overcome for the achievement of around 30% efficiencies in the AlGaAs/GaAs cascade cell under concentrator applications are also discussed. (orig.).
1991-05-01
A model for Schottky-barrier solar cell analysis
A general model for the analysis of metal-semiconductor solar cells is presented. The model takes into account the cell optical properties, carrier recombination effects, semiconductor minority-carrier properties, series resistance, cell thickness, and active surface area. Numerical methods are used to solve the appropriate continuity equations and hence compute the photocurrent density under AMO conditions. The operation of the model is demonstrated using p- and n-type Si and GaAs with Au being taken as the barrier metal. Calculations are presented showing the effect on solar energy conversion efficiency of surface recombination velocity, barrier height, minority-carrier lifetime, barrier metal thickness, collecting grid configuration, and cell thickness. A comparison of practical and computed data for the Au/n-GaAs system yields good agreement. (AIP)
1976-05-01
Study on reactivity measurement by the Feynman-#alpha# method
International Nuclear Information System (INIS)
The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).
1996-09-01
Si(111)/Gd: A fast and high-resolution thermal neutron detector
Energy Technology Data Exchange (ETDEWEB)
Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.
1998-07-01
Energy Technology Data Exchange (ETDEWEB)
Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.
1993-01-01
Research in experimental elementary particle physics. A proposal to the U.S. Department of Energy
Energy Technology Data Exchange (ETDEWEB)
We report on the activities of the High Energy Physics Group at the University of Texas at Arlington for the period 1994-95. We propose the continuation of the research program for 1996-98 with strong participation in the detector upgrade and physics analysis work for the D0 Experiment at Fermilab, prototyping and pre-production studies for the muon and calorimeter systems for the ATLAS Experiment at CERN, and detector development and simulation studies for the PP2PP Experiment at Brookhaven.
1995-04-13
Radon concentration measurements in the soil
International Nuclear Information System (INIS)
Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)
Proposed high-resolution vertex detector using superconductive thin strips
Energy Technology Data Exchange (ETDEWEB)
The possibility of fabricating a superconductive vertex detector is discussed on the basis of a preliminary experiment. The experiment has shown that an indium strip 15 mm long, 20 ..mu..m wide and 0.1 ..mu..m thick is changed from the superconductive state to the normal state when struck by a single 5.4 MeV alpha particle.
1984-06-01
Portable real time neutron spectrometry II
International Nuclear Information System (INIS)
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
2000-01-19
Portable real time neutron spectrometry
International Nuclear Information System (INIS)
We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.
1999-01-22
Performance of the transition radiation detector in D{Phi}
Energy Technology Data Exchange (ETDEWEB)
The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.
1994-12-31
Performance of a large Bragg-curve spectrometer
Energy Technology Data Exchange (ETDEWEB)
A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.
1987-04-01
Performance of a large Bragg-curve spectrometer
International Nuclear Information System (INIS)
A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).
Energy Technology Data Exchange (ETDEWEB)
MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.
2006-06-12
Medical explorations by radioisotopes in Lebanon
International Nuclear Information System (INIS)
This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.
Interaction region layout of the VLEPP based photon linear collider with ultimate luminosity
Energy Technology Data Exchange (ETDEWEB)
In the present paper, a possible interaction region layout of the VLEPP based Photon Linear Collider (PLC) with ultimate luminosity is discussed. In order to remove spent electron beams, the crab-crossing scheme is used. The detector is protected from produced pairs and secondary particles by means of the detector magnetic field and a shielding mask. ((orig.)).
1995-02-01
Gamma ray detecting device using dislocation-free crystal
Energy Technology Data Exchange (ETDEWEB)
This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.
1991-04-30
First tests of "bulk" MICROMEGAS with resistive cathode mesh
We present the first results from tests of a MICROMEGAS detector manufactured using the so-called "bulk" technology and having a resistive cathode mesh instead of the conventional metallic one. This detector operates as usual MICROMEGAS, but in the case of sparks, which may appear at high gas gains, the resistive mesh reduces their current and makes the sparks harmless. This approach could be complementary to the ongoing efforts of various groups to develop spark-protected MICROMEGAS with resistive anode planes.
2010-01-01
Explosives detection: the problem and prospects
Energy Technology Data Exchange (ETDEWEB)
The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.
1984-01-01
Direct gamma-spectrometry of surface activity with IGC-30 HPGe detector
International Nuclear Information System (INIS)
The IGC-30 HPGe detector with MCA 'CANBERRA-10 PLUS' allows to determine surface contamination of areas of any type with a minimum error in radius 8-10 m, at a 'uniform' contamination. A modification of the CANBERRA hardware and software is described allowing determination of both the activity of a possible 'radioactive spot' and the activity of the whole observed surface. (author).
1993-12-02
Development of a real-time, neutron and gamma dosimeter
Energy Technology Data Exchange (ETDEWEB)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-07-01
Development of a real-time, neutron and gamma dosimeter
International Nuclear Information System (INIS)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
2001-06-10
Determination of reactor kinetic parameters in a two-core reactor
Energy Technology Data Exchange (ETDEWEB)
The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.
1982-01-01
Detector questions for a gamma-gamma collider
Energy Technology Data Exchange (ETDEWEB)
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
1995-02-01
Detector questions for a gamma-gamma collider
International Nuclear Information System (INIS)
The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).
Detection device for high explosives
Energy Technology Data Exchange (ETDEWEB)
A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.
1992-01-01
A system for inspecting a ceramic component. The ceramic component is positioned on a first rotary table. The first rotary table rotates the ceramic component. Light is directed toward the first rotary table and the rotating ceramic component. A detector is located on a second rotary table. The second rotary table is operably connected to the first rotary table and the rotating ceramic component. The second rotary table is used to move the detector at an angle to the first rotary table and the rotating ceramic component.
2006-05-16
CPA simulator: A software tool to simulate nuclear front-end circuit response
International Nuclear Information System (INIS)
A computer program 'CPA simulator' has been designed to simulate the response parameters of a typical charge preamplifier (CPA) used in nuclear front-end electronics. The response parameters are studied considering three common connection methods between the detector and the CPA. The simulator predicts and illustrates the role and influence of the different components of the CPA and detector circuits.
2010-12-21
Assessment of detector sensitivity and uniformity during SPECT rotation
International Nuclear Information System (INIS)
The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity variation curves and ...
1984-06-05
Applications of Bonner sphere detectors in neutron field dosimetry
Energy Technology Data Exchange (ETDEWEB)
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
1983-09-01
International Nuclear Information System (INIS)
The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side ...
2005-11-23
An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy
Energy Technology Data Exchange (ETDEWEB)
An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).
1991-12-01
Energy Technology Data Exchange (ETDEWEB)
The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation ...
1995-11-01
International Nuclear Information System (INIS)
Surface barrier detectors may be damaged, because of microplasma breakdown, in rapid application of bias voltage. The high performance FETs of very low noise preamplifiers may also be damaged by rapid changes of the bias voltage. The electronic device described permits the gradual application and removal of the bias voltage, without any influence on the power supply specification. (Auth.).
A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode
Energy Technology Data Exchange (ETDEWEB)
A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))
1994-07-15
Energy Technology Data Exchange (ETDEWEB)
Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.
1994-06-01
Recent Progress in CdTe and CdZnTe Detectors
Cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) have been regarded as promising semiconductor materials for hard X-ray and Gamma-ray detection. The high atomic number of the materials (Z_{Cd} =48, Z_{Te} =52) gives a high quantum efficiency in comparison with Si. The large band-gap energy (Eg ~ 1.5 eV) allows us to operate the detector at room temperature. However, a considerable amount of charge loss in these detectors produces a reduced energy resolution. This problem arises due to the low mobility and short lifetime of holes. Recently, significant improvements have been achieved to improve the spectral properties based on the advances in the production of crystals and in the design of electrodes. In this overview talk, we summarize (1) advantages and disadvantages of CdTe and CdZnTe semiconductor detectors and (2) technique for improving energy resolution and photopeak efficiencies. Applications of these ...
2001-01-01
Design and implementation of the BESIII detector-control system
Energy Technology Data Exchange (ETDEWEB)
In the upgrade project of the Beijing Electron-Positron Collider (BEPCII), a novel Detector-Control System (DCS) for the Beijing Spectrometer (BESIII) has been built and started its successful operation for the BESIII Commissioning. The main task of the DCS is to monitor and control the status of the BESIII detector and to guarantee a safe operation of the detector. The DCS must provide a uniform and coherent interface to detector operators even though there are a large number of distributed I/O channels from a large variety of equipments. For this reason, the DCS is hierarchically organized and divided into three layers: front-end layer (FEL), local control layer (LCL) and global control layer (GCL). In the FEL, devices ranging from simple sensors up to complex computer-based devices like embedded systems and programmable logical controllers (PLC) are utilized. A LabVIEW-based software framework has ...
2008-07-21
Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices
International Nuclear Information System (INIS)
Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and special nuclear materials. ...
2005-10-23
Wet chemical etch solutions for Al{sub x}Ga{sub 1{minus}x}P
Heterostructures based on AlGaInP alloy compounds are very attractive for visible semiconductor lasers, heterojunction bipolar transistors (HBTs), and high-electron-mobility transistors (HEMTs) lattice matched to GaAs substrates. Several wet etching solutions for AlGaP of different compositions have been studied. Al{sub 0.5}Ga{sub 0.5}P is found to etch in HF, H{sub 3}PO{sub 4}, hyphosphorous acid (HOPH{sub 2}:O), HCl, KOH, and 1% Br{sub 2}-methanol (MeOH). Etching of Al{sub 0.5}Ga{sub 0.5}P in HCl is reaction limited with an activation energy of {approximately}54.4 kJ/mol. At fixed conditions, the etch rates of Al{sub x}Ga{sub 1{minus}x}P vary exponentially with x in HF and HCl, while in 1% Br{sub 2}-MeOH and mixtures of HCl and HNO{sub 3} the etch rates follow a linear dependence on AlP mole fraction. HF has been found to be a good etchant for AlGaP over InGaP or AlInP with high selectivity, while HCl is useful for the reverse case. The use of 1% Br{sub 2}-MeOH ...
1996-01-01
Solid-state precursor routes to III-V type electronic (13-15) and magnetic (3-15) materials
An interest in electronic materials has led me to investigate new synthetic approaches to III-V' type semiconducting (13-15, current IUPAC designation for B and N groups in the Periodic Table) and magnetic (3-15) compounds. It is now possible to prepare binary (GaAs and GdP) and ternary mixed-metal (Al[sub x]Ga[sub 1-x]As) and mixed-pnictide (GaP[sub x]As[sub 1-x]) compounds in seconds from rapid, low-temperature-initiated metathesis reactions between a metal (III) trihalide and a trisodium pnictide, exemplified by MX[sub 3] + Na[sub 3]Pn [yields] MPn + 3 NaX, where M is Al, Ga, In, (Al,Ga), or a lanthanide; X is F, Cl, or I; and Pn is P, As, Sb, or (P,As). The precursors are mixed together in a dry box and ignited by light grinding with a mortar and pestle, or by brief, local heating from a hot filament. These reactions are very exothermic (calculated [Delta]H[sub rxn] (GaAs) = 138 kcal/mol) and typically reach temperatures in excess ...
1992-01-01
Influence of phosphorus vapor ambient for InGaAsP growth on GaAs substrate
For visible-light-emitting laser diodes, InGaAsP double heterostructures have been grown on GaAs substrates using liquid-phase epitaxy. As the growth temperature is as high as about 780 /sup 0/C, a large amount of phosphorus evaporates from the solutions for the cladding layers during the growth process. The phosphorus vapor disturbs the solution composition for the active layer, so that very thin and uniform active layers cannot be obtained. By using In-P-Sn solution and supplying the phosphorus partial pressure around the graphite boat, the influence of phosphorus vapor ambient for InGaAsP (lambda/sub P//sub L/ = 805 nm) growth is confirmed. When the phosphorus partial pressure increases, the surface of epitaxial layer becomes rough and the substrate is partly etched back. From x-ray diffraction and photoluminescence spectral measurements, the composition of the grown layer is also found to be changed. As a result of increasing the flow rate of H/sub 2/ gas in ...
1986-12-01
International Nuclear Information System (INIS)
We report on the transport properties of a high mobility two-dimensional hole system (2DHS) confined in GaAs/AlGaAs quantum wells grown by molecular-beam epitaxy on the (100) surface of GaAs. The quantum wells are modulation doped with carbon utilizing a resistive filament source. At T=0.3 K and carrier density p=1x10"1"1 cm"-"2, a mobility of 10"6 cm"2/Vs is achieved. At fixed carrier density p=10"1"1 cm"-"2, the mobility is found to be a nonmonotonic function of the quantum well width. The mobility peaks at 10"6 cm"2/Vs for a 15-nm well and is reduced for both smaller and larger well widths for these (100) samples. The mobility anisotropy is found to be small. Mobility along [011] is approximately 20% higher than along the [011] direction. In addition, the low-temperature carrier density is found to have low sensitivity to light. The hole density increases by only #approx#10% after exposure to red light at T=4.2 K. In structures designed for a lower carrier ...
2005-04-18
Energy Technology Data Exchange (ETDEWEB)
Inverted growth and the development of associated cell processing, are likely to offer a significant degree of freedom for improving the performance of many III-V multijunction cascades and open new avenues for advanced multijunction concepts. This is especially true for the development of high-efficiency Al[sub 0.37]Ga[sub 0.63]As/GaAs cascades where the high growth temperatures required for the AlGaAs top cell growth can cause the deterioration of the tunnel junction interconnect. In the approach of inverted-grown AlGaAs/GaAs cascade cells, the AlGaAs top cell is grown first at 780 [degree]C and the GaAs tunnel junction and bottom cell are grown at 675 [degree]C. After the inverted growth, the AlGaAs/GaAs cascade structure is selectively removed from the parent substrate. The feasibility of inverted growth is demonstrated by a fully-processed, inverted-grown, thin film GaAs cell with a 1-sun AM1.5 efficiency of 20.3%. Also, an inverted-grown, ...
1992-12-01
Charge and fluence lifetime measurements of a dc high voltage GaAs photogun at high average current
Energy Technology Data Exchange (ETDEWEB)
GaAs-based dc high voltage photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed high average current facilities that must operate at tens of milliamperes or more. This paper describes techniques to maintain good vacuum while delivering beam, and techniques that minimize the ill effects of ion bombardment, the dominant mechanism that reduces photocathode yield of a GaAs-based dc high voltage photogun. Experimental results presented here demonstrate enhanced lifetime at high beam currents by: (a) operating with the drive laser beam positioned away from the electrostatic center of the photocathode, (b) limiting the photocathode active area to eliminate photoemission from regions of the photocathode that do not support efficient beam delivery, (c) using a large drive laser beam to distribute ion damage over a larger area, and (d) by applying a relatively low bias ...
2011-04-01
Energy Technology Data Exchange (ETDEWEB)
A technique has been developed at the Idaho National Engineering Laboratory to sum high resolution gamma-ray pulse spectra from systems with multiple Ge detectors. Lockheed Martin Idaho Technologies Company operates a multi-detector spectrometer configuration at the Stored Waste Examination Pilot Plant facility which is used to characterize the radio nuclide contents in waste drums destined for shipment to Waste Isolation Pilot Plant. This summing technique was developed to increase the sensitivity of the system, reduce the count times required to properly quantify the radionuclides and provide a more consistent methodology for combining data collected from multiple detectors. In spectrometer systems with multiple detectors looking at non homogenous waste forms it is often difficult to combine individual spectrum analysis results from each detector to obtain a meaningful result for ...
1997-05-01
A large surface neutron and photon detector for civil security applications
Energy Technology Data Exchange (ETDEWEB)
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
2010-05-21
A large surface neutron and photon detector for civil security applications
International Nuclear Information System (INIS)
The security of ports and transportation is of utmost importance for the development of economy and the security of a nation. Among the necessary actions to ensure the security of ports and borders, the inspection of containers is one of the most time consuming and expensive procedures. Potential threats are the illegal traffic of radioactive materials that could be employed for the construction of weapons, as uranium and plutonium. New techniques for the inspections of containers should be fast, allow the detection and identification of dangerous materials, and be non-invasive, to reduce costs and delays. We propose to build a large surface photon and neutron detector based on plastic scintillator to identify the presence of fissile or fertile material inside a container. The detector consists of scintillator bars, wrapped in thin foils of reflecting material containing gadolinium for neutron capture and arranged in planes separated by ...
2010-05-11
International Nuclear Information System (INIS)
The use of primary electron counting techniques as an alternative to the more usual parallel plate avalanche chamber that has been employed in soft x-ray scattering experiments is being investigated at the National Synchrotron Light Source. The theoretical aspects of primary electron counting and motivation behind building a primary electron counting detector are described, as well as characteristics and future improvements of the device constructed at the NSLS. The detector consists of a low electric field drift region and a low pressure multistep avalanche region which can be operated with two or three stages of electron multiplication. The device has worked well in extensive tests as a simple parallel plate avalanche chamber, providing energy resolutions of 58% and 43% at 277 and 500 eV, respectively. Operated as a primary electron counter, preliminary results show an energy resolution of 38% at 500 eV.
Ultraviolet detectors based on ZnO films by thermal oxidation of Zn metallic films
British Library Electronic Table of Contents (United Kingdom)
Metallic Zn films were deposited on glass substrates by electron-beam evaporation. ZnO films were synthesized by thermal oxidation of Zn metallic films in air. At the annealing temperature of 550 ?C, ZnO nanowires appeared on the surface, which mainly result from the decrease of oxidation rate. A ZnO ultraviolet photodetector was fabricated based on a metal-semiconductor-metal planar structure. The detector showed a large UV photoresponse with an increase of two orders of magnitude. It is concluded that promising UV detectors can be obtained on ZnO films by thermal oxidation of Zn metallic films. The ways of performing spectral response measurements for polycrystalline ZnO films are also discussed.
2008-01-01
Superconducting strip detectors as position sensitive particle detectors
Energy Technology Data Exchange (ETDEWEB)
The feasibility of using of current-biased superconducting strips for radiation detection is investigated. Narrow Ta strips are exposed to 5.5 MeV [alpha]-particle radiation and the rise-time of the induced voltage pulses is measured as function of temperature and bias current. The rise-time of the voltage signal strongly depends on the site on the strip which is hit by the [alpha]-particle. In order to determine the spatial resolution of a superconducting strip detector, position-sensitive measurements were performed. The maximum lateral resolution estimated so far is 25[mu]m in a 7[mu]m wide, 340 nm thick and 0.6 mm long Ta-strip. (orig.)
1994-02-01
Status of combined point source search with neutrino telescopes IceCube and AMANDA
Energy Technology Data Exchange (ETDEWEB)
In this talk, we summarize recent results obtained from the combined neutrino telescopes IceCube and AMANDA. The combined approach, including data taken from both detectors simultaneously, is compared to other analyses that are using IceCube only data. The main benefit of the combined detector is its improved performance at low energies, meaning energies below 1 TeV (close to the energy threshold of the detector). The discussion is focused on the search for extra-terrestrial neutrinos from candidate sources in our Galaxy. Using appropriate cuts, the sensitivity can be optimized for soft spectra neutrino sources. With the resulting data sample, several studies are performed: an unbinned Galactic Plane Scan and a Cygnus region analysis: the Multi Point Source analysis. The current status of these analyses is presented.
2010-07-01
Spatial distribution of IGC-30 Ge-detector's efficiency
International Nuclear Information System (INIS)
The dependence of the efficiency of a coaxial IGC-30 Ge detector on the direction of gamma quanta entry, their energy and the distance from the source is examined. A set of point sources QCR-2 (Amersham, UK) has been used which is arranged consecutively in two perpendicular planes passing through the detector axis, at a distance of 0.1 - 1.3 m (pace 0.1) from its geometric centre for 16 different angles in every plane. Dependence curves of the efficiency on the angle of gamma-quanta hits are obtained for energies 60, 81, 122, 356, 662, 834, 1173 and 1332 keV. Changes in efficiency connected with spatial dividing ability are found out. Using the least squares' method the expected spatial distribution of efficiency is examined with a level of authenticity P > 0.9. The possible causes for the efficiency change and its possible effect on the measurements' precision are discussed. (author).
1993-12-02
Some considerations about future interferometric GW detectors
International Nuclear Information System (INIS)
The two most important issues in designing future gravitational wave interferometric detectors are, in our opinion, thermal and optical noise. In this paper we discuss some approaches for reducing these noises. About thermal noise we show a possible cryogenic solution. About optical noise (namely, the combined effect of shot noise and radiation pressure noise) we show that it is possible to apply a recently proposed reduction strategy based on a 'quantum feedback' (Courty et al 2003 Phys. Rev. Lett. 90 083601; Courty et al 2003 Preprint gr-qc/0301068) to a full Fabry-Perot cavity. This can be seen as a further step towards the practical realization of a detector which is able to evade the standard quantum limit.
2004-03-07
Quartz fiber calorimetry and calorimeters
Quartz fiber calorimetry is a technique the signal generation mechanism of which is based on the Cherenkov effect. In this article we try to give a comprehensive overview of the subject. We start with a general introduction to calorimetry where the basic elements that characterize the development of electromagnetic and hadronic showers are discussed. Then we describe in detail the operation principle and the properties of calorimeters equipped with quartz fibers. The main advantages of this type of calorimeters are the radiation hardness, the fast response and the compact detector dimensions, features that derive from the quartz material and the specific mechanism of operation. A section is devoted to presenting the quartz fiber calorimeters that have been built or planned to in various experiments to operate as centrality detectors, trigger detectors, luminosity monitors or general purpose very forward calorimeters.
2004-01-01
Plane electrode device for multiwire detector for ionizing radiations
International Nuclear Information System (INIS)
A multiwire proportional counter type detector with thin slits instead of wires is presented. It can detect either charged particles (positive or negative) or radiation. The detector can be used as a counter or as an image converter. In radiography, it can replace photographic film or TV camera systems. It can also be used to measure particle or radiation energy. The slits which replace wires in the anode are introduced between two parallel microstrip conductors with different potentials. A quasi-polar electric field is produced between these strips. To obtain high fields, the slits are extremely narrow. Microstrips less than a micron can be obtained, giving structural dimensions of a few microns, i.e., 100 times smaller than the spacing in a classic wire anode.
1986-07-01
Particle and X-ray damage in pn-CCDs
Energy Technology Data Exchange (ETDEWEB)
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
2000-01-11
International Nuclear Information System (INIS)
A mathematical model of multichannel radiometric inspection system was developed, in which the measurement results are reproduced in the form of a half-tone image equivalent to the radiation image of the irradiated object. The model makes the following assumptions: the beam of radiation is fan-shaped; the object of inspection is scanned discretely; the focal spot of the source is rectangular; the apertures of the detector are round, and the detectors themselves are equidistant from the sources, aimed at it, and form a close-packed array; the signals from the detectors are processed according to a time scheme; and the measurement results are corrected in a computer for normalizing the gains of the channels of the system. The mathematical model can serve as the basis for developing a method of calculating the optimal parameters of a multichannel radiometric system with visualization of the radiation images. 14 refs., 2 figs.
Measurement of radon daughter product burden by TLD dosemeters
International Nuclear Information System (INIS)
A miniature device is described for measuring integral potential alpha energy concentration of radon daughter products (Csub(Rn)) for personnel and stationary dosimetry. The measuring apparatus consists of an air sampler, filters and TLD detectors. CaSO_4:Dy-teflon pellets were used as the detectors which registrate #gamma# radiation as well. The TLD-effect dependence on the potential alpha energy, as well as the fading of the detectors at 20-60 deg C after 170 hrs operation are presentd. The fading up to 40 deg C has been found to be negligible. The dosimeter may be used to measure Csub(Rh) starting with the 10"5 MeVxh/1 threshold, the accuracy being not worse than +-30%.
Magnetic beam position monitor
Energy Technology Data Exchange (ETDEWEB)
Many nondestructive beam position monitors are known. However, these devices can not be used for DC particle beam diagnostics. We investigated a method of beam diagnostics applicable for the operative control of DC high power e-beam inside closed waveguide. A design of the detector for determination of{open_quote} center of mass {close_quote} position of DC particle beam was developed. It was shown that the monitor can be used as a nondestructive method for the beam position control in resonators. Magnetic field of the particle beam outside a resonator is used. The detector consists of the steel yokes and magnetic field sensors. The sensors measure magnetic fluxes in the steel yokes fixed outside the resonator. When the particle beam changes its position, these magnetic fluxes also change. Beam displacement sensitivity of the monitor depends on the steel yoke dimensions. The detector sensitivity is equal to 1 Gauss/mm for ...
1995-12-31
Ion beam induced charge imaging of epitaxial GaN detectors
Energy Technology Data Exchange (ETDEWEB)
We report the use of ion beam induced charge imaging to characterise the charge signal uniformity of epitaxial gallium nitride radiation detectors. The detectors were fabricated from 2 {mu}m thick semi-insulating gallium nitride, grown by MOCVD on a sapphire substrate. A carrier concentration of 1.4x10{sup 15} cm{sup -3} was measured using capacitance-voltage measurements. Ion beam induced charge imaging was carried out with a 2 MeV alpha particle beam focussed to a 3 {mu}m diameter and raster scanned across the device. The resulting ion beam images show excellent charge signal uniformity in this material with no evidence of material defects or polycrystalline structure on the micrometer length scale. No evidence of charge signal trapping was observed in these devices.
2004-09-21
Energy Technology Data Exchange (ETDEWEB)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
1991-01-01
International Nuclear Information System (INIS)
A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).
British Library Electronic Table of Contents (United Kingdom)
Indoor and soil gas Radon (222Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor 222Rn gas concentration values. In the second stage, soil gas 222Rn measurements were performed using an alphameter near the selected h...
2010-01-01
High Energy Neutrino Telescopes
This paper presents a review of the history, motivation and current status of high energy neutrino telescopes. Many years after these detectors were first conceived, the operation of kilometer-cubed scale detectors is finally on the horizon at both the South Pole and in the Mediterranean Sea. These new detectors will perhaps provide us the first view of high energy astrophysical objects with a new messenger particle and provide us with our first real glimpse of the distant universe at energies above those accessible by gamma-ray instruments. Some of the topics that can be addressed by these new instruments include the origin of cosmic rays, the nature of dark matter, and the mechanisms at work in high energy astrophysical objects such as gamma-ray bursts, active galactic nuclei, pulsar wind nebula and supernova remnants.
2008-01-01
Feasibility study of the iterative x-ray phase retrieval algorithm
International Nuclear Information System (INIS)
An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.
2009-01-01
Cooling device for impurity removal device in thermonuclear devices
International Nuclear Information System (INIS)
Purpose: To prevent structure material meltdown upon rupture of cooling pipeways in a impurity remover by preventing the coolants from flowing into the vacuum vessel while continuing the supply of coolants to other portions to be cooled. Constitution: Dual cooling pipeway systems are disposed to the neutralizing plates of the impurity remover. A rupture detector (pressure gage) is mounted to each of the cooling pipeways and flow rate control valves to be opened and closed by the signal from the detector are disposed to the upstream and downstream of the cooling pipeway. In this constitution if the cooling pipes should be ruptured, the coolant supply is stopped to the ruptured system in which the flow rate valve is closed by the signal from the rupture detector. However, since the coolant is kept to be supplied to the other system of the cooling pipeways, meltdown of the neutralizing plates can be prevented. (Kamimura, M.).
1983-08-26
Aging measurements of a TMAE-based photon detector for the HERA-B RICH
We report on aging measurements of a photon detector candidate for the HERA-B RICH. The prototype, a proportional wire chamber operated with TMAE, was mounted on an argon filled test-beam RICH and was aged by UV light at rates we expect in HERA-B. We monitored gain and current continuously, and checked the chamber with Cherenkov photons at regular intervals. The number of detected photons/track (projected to 2.75 m C sub 4 F sub 1 sub 0 in HERA-B) dropped from 26 to 11 after two days of aging - well below the 20 required for pi/K separation. Based on these results, HERA-B decided to use multi-anode PMTs as photon detectors in the RICH.
1999-01-01
Energy Technology Data Exchange (ETDEWEB)
The /sup 252/Cf-source-driven noise analysis method determines the subcriticality of a system containing fissionable material from the ratio of cross power spectral densities between the detectors that detect particles from the fission process and between these detectors and an ionization chamber containing a spontaneously fissioning neutron source which provides neutrons to induce fission in the system. This method has two advantages: (1) a calibration is not required and thus subcriticality can be determined from measurements only on the subcritical system of interest, and (2) the subcriticality is independent of the type of detector or its efficiency. These properties of this technique are illustrated by measurements.
1984-01-01
British Library Electronic Table of Contents (United Kingdom)
An analytical method was proposed for calculating radiative fluxes incident on a planar circular detector from a volume multiple point chemi- or bio-luminescent source inside a coaxial cylindrical reactor. The method was designed for a cylindrical reactor when the surface reflections were neglected and when chemi- or bio-luminescence reaches a detector embedded in the same homogeneous optical medium as the point emitters of the volume multiple point source model. The radiative fluxes from arbitrarily distributed point emitters were expressed by one generalized quadruple-integral formula. Then some double- and single-integral formulas were obtained for calculating radiative fluxes from identically radiating point emitters uniformly distributed within the reactor. Selected results were compu...
2009-01-01
Using Military Working Dog Teams (MWDTs) to Support Law ...
... 4. Military Working Dogs iMWDs). As used in this Instruction refers to drug detector dogs only. 5. Military Working Doq Executive Agent M(WJDEMA. ...
1990-09-17
Use of solid state nuclear track detectors for radon concentration measurements indoors
International Nuclear Information System (INIS)
An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.
The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy
UK PubMed Central (United Kingdom)
BackgroundMany studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for...Full Text Available
The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the ...
2009-01-01
The Development of a Neutral Particle Detector for Observations of the Thermosphere
One of the least understood regions of the upper atmosphere is the thermosphere, principally due to the difficulty of making observations. The neutral atmosphere is known to be highly variable, and its composition and density varies by several orders of magnitude due to solar activity, diurnal cycles, latitude, geomagnetic activity, and gravity waves. In the past, most in-situ measurements of the neutral atmosphere have utilized detectors that are dependent on arrival angle and energy accommodation of incoming species, so that information related to nascent velocity distribution and reactive species abundances is often masked. This paper will review design concepts and laboratory tests related to the development of a novel open-ionizer, neutral particle detector for space environment measurements which can overcome these limitations. The sensor features a very large field-of-view suitable for sounding rocket missions. This time-of-flight ...
2006-12-01
Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector
UK PubMed Central (United Kingdom)
To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available
2011-03-01
Energy Technology Data Exchange (ETDEWEB)
The results of a search for fractionally charged particles produced in e/sup +/e/sup -/ annihilation at 29 GeV/c/sup 2/ are discussed. Results from cosmic-ray searches for fractionally charged particles, tachyons, and massive particles using the same detector are also presented.
1982-01-01
Research in heavy-ion nuclear physics
Energy Technology Data Exchange (ETDEWEB)
This report discusses the following topics: Fusion-fission in light nuclear systems; High-resolution Q-value measurement for the {sup 24}Mg+{sup 24}Mg reaction; Heavy-ion reactions and limits to fusion; and Hybrid MWPC-Bragg curve detector development.
1992-01-01
Radon concentration measurement in dwellings in Belgrade
International Nuclear Information System (INIS)
The results of the radon concentration measurements in dwellings in Belgrade were shown in this paper. The measurements were done using long term method with diffusion cups equipped with solid state nuclear track detector LR-115-II or CR-39. (author).
Post-column reaction detector for platinum(II) antieoplastic agents
Energy Technology Data Exchange (ETDEWEB)
The development and evaluation of a post-column reaction detector sensitive to platinum(II) complexes is presented in which sodium bisulfite is used as the derivatizing agent with potassium dichromate as an activating agent. The influences of mobile phase changes (i.e., pH, organic modifiers, electrolytes), oxygen, metal ions, and order of reagent addition on reaction kinetics and product yield are defined and used in optimization of detector response. Detection at lambda/sub max/ 290 nm results in an on-line post-column sensitivity of 40-60 ng/mL for selected cis-dichloroplatinum complexes and a sensitivity of 300-1200 ng/mL for four (substituted)-malonato-platinum complexes. The reaction detector is used to monitor the kinetics of aquation of cisplatin (CDDP) and to quantitate CDDP degradation in plasma. As the sensitivity for CDDP in plasma is comparable to that achieved from high pressure liquid chromatography (HPLC) ...
1984-03-01
Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies
International Nuclear Information System (INIS)
A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 refs., 2 figs.
Photoconductive ultraviolet detectors based on ZnO films
Energy Technology Data Exchange (ETDEWEB)
Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant {tau} obtained from the curve fitting represents the ...
2006-12-15
Photoconductive ultraviolet detectors based on ZnO films
International Nuclear Information System (INIS)
Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360 nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8 mA, and a slow photoresponse with a rise time of 5 min and a decay time of 7 min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the decrease of the barrier height between crystallites. The relaxation time constant #tau# obtained from the curve fitting represents the ...
2006-12-15
Energy Technology Data Exchange (ETDEWEB)
GaN and Al{sub 1{minus}x}Ga{sub x}N films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10{sup 9} ohm-cm and 10{sup {minus}3}--10{sup {minus}8} cm{sup 2}/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.
1997-12-31
International Nuclear Information System (INIS)
GaN and Al_1_-_xGa_xN films were grown by the method of ECR-MBE. Absorption constants as a function of wavelength were determined from transmission measurements. Photoconducting detectors were fabricated from these films and characterized in terms of their spectral response and photoconductive gain. Mobility-lifetime products were determined from the measurement of photoconductive gain. The resistivity and mobility-lifetime products of the films were varied from 10--10"9 ohm-cm and 10"-"3--10"-"8 cm"2/V respectively by changing the microwave power in the ECR discharge from 20--60 watts. The change in the mobility-lifetime product is attributed to change in the lifetimes of the photogenerated carriers. This assumption is supported by direct measurement of detector response times. Finally, the authors report for the first time, the detection of alpha particles using GaN detectors.
1996-12-02
Performance assessment for EEG-based neonatal seizure detectors
UK PubMed Central (United Kingdom)
ObjectiveThis study discusses an appropriate framework to measure system performance for the task of neonatal seizure detection using EEG. The framework is used to present an extended...Full Text Available
2011-03-01
Optical Modelling of the HFI Instrument on Board the Planck Surveyor
The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the telescope. Although the ...
1999-07-01
Online processing in the ALICE DAQ The detector algorithms
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes more than 30 ...
2010-01-01
On-line real-time measurements of decontamination factor for a low-level waste incinerator
Energy Technology Data Exchange (ETDEWEB)
The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.
1983-01-01
On-line real-time measurements of decontamination factor for a low-level waste incinerator
International Nuclear Information System (INIS)
The experiments at the incinerator for low-level wastes processing, (containing transuranium radionuclides) are described. Air decontamination factors and detector readings correction factors for efficiency and absorption are indicated.
Novel remote sensing gas outburst detector
Energy Technology Data Exchange (ETDEWEB)
The possibility has been explored of using a laser scattering technique to detect the imminent onset of rock activity associated with gas outbursts. The instrument described in this paper provides a sensitive, remote and rapid means of passively monitoring micro-seismic activity at the exposed face.
1984-08-01
UK PubMed Central (United Kingdom)
The reference medium for brachytherapy dose measurements is water. Accuracy of dose measurements of brachytherapy sources is critically dependent on precise measurement of the source–detector...Full Text Available
2010-01-01
Midwave infrared type-II InAs/GaSb superlattice detectors with mixed interfaces
We report the growth and fabrication of midwave infrared InAs/GaSb strain layer superlattice (SLS) detectors. Growth of alternate interfaces leads to a reduced strain between the GaSb buffer and SLS ({delta}a{sub parallel}/a=-5x10{sup -4}), enabling the growth of active regions up to 3 {mu}m (625 periods). The structural, optical, and electrical properties of the active region were characterized using x-ray crystallography and photoluminescence, respectively. p-i-n detectors were grown using 625 periods of 8 ML (monolayer) InAs/8 ML GaSb as the active region. The {lambda}{sub cutoff} for the detectors was 4.6 {mu}m with a conversion efficiency of 32% at V{sub b}=-0.2 V. Detectivity was obtained using noise power spectral density measurements under 300 K 2{pi} field of view illumination and was equal to 5.2x10{sup 10} and 3x10{sup 10} cm Hz{sup 1/2}/W (V{sub b}=-0.02 V, T=80 K) in the white noise and 1/f noise limit (at 50 ...
2006-07-01
International Nuclear Information System (INIS)
In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component of a fiber-optic radiation ...
2007-08-21
Measurement of gamma-ray detection efficiency in irradiated materials examination facility
Energy Technology Data Exchange (ETDEWEB)
The detection efficiency of gamma scanning system in irradiated materials examination facility has been measured. Gamma-ray sources used in this experiment are Cs-Co standard sources a PWR spent fuel rod in which {sup 134}Cs and {sup 154}Eu peaks are clearly identified in the energy region of 500 to 1,600 keV. The distance between source and detector is about 1.6 m. A slit type collimator with 3 mm-width window and 30 mm-thick lead block are installed between source and detector. The detector is a HPGe detector. This equipment is mainly used in gamma scanning of irradiated nuclear fuel. The measured detection efficiency seems to be 1.89 x 10{sup -6} % for 1 MeV gamma-ray. With these results the activities of unknown sources could be measured. This results are expected to be used in the measurement of the absolute distribution of gamma emitting nuclides in nuclear fuel.
2001-05-01
MAGIC - Multi Anode Gas Ionization Chamber
Energy Technology Data Exchange (ETDEWEB)
A novel approach to the Bragg curve spectroscopy is utilized to construct a charged particle detector which makes fragment elemental identification and energy measurement possible. The advantage of the construction includes good timing and spectroscopic properties with a very low energy threshold. ((orig.))
1994-12-01
Investigation of the decay scheme of $sup 177$W by means of $gamma$-- $gamma$ coincidences
The gamma spectrum and gamma - gamma coincidences of /sup 177/W were measured with a Ge(Li) detector. A level scheme was proposed for /sup 177/Ta. (tr-auth)
1973-08-01
Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982
Energy Technology Data Exchange (ETDEWEB)
Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; ...
1982-12-01
Indoor radon concentration measurements by using SSNTD
International Nuclear Information System (INIS)
In this paper, some results of the indoor radon concentration measurements are presented. Kodac track detectors LR 115, bare and in a cup were used for these measurements. Average winter/summer ratio was determined for the town of interest. (author). 5 refs, 1 fig., 1 tab.
Indoor radon concentration measurements
International Nuclear Information System (INIS)
Some results of the indoor radon measurements are presented in this paper. Kodac track detectors LR-115 were used for these measurements. Average winter/spring ratio for indoor radon concentration was determined from the results obtained and is presented in this paper. (author).
Front-End-Electronics Communication software for multiple detectors in the ALICE experiment
Energy Technology Data Exchange (ETDEWEB)
In the ALICE experiment at CERN, the Detector Control System (DCS) employs several interacting software components to accomplish its task of ensuring the correct operation and monitoring of the experiment. This paper describes the Front-End-Electronics Communication (FeeCommunication) software and its role within the DCS. The FeeCommunication software's central task is passing configuration and monitoring data between the top level DCS process control and the field devices of several detectors within ALICE. The lowest level of the FeeCommunication software runs on the DCS boards, specialized embedded systems which are in direct contact with the field devices and are physically located within the detector. The middle and upper layers run on standard PC hardware located in the counting room or other external locations. This paper focuses on the design and implementation of the FeeCommunication software and the steps ...
2006-02-15
Forschungszentrum Juelich, Institut fuer Kernphysik/COSY. Annual report 2004
Energy Technology Data Exchange (ETDEWEB)
The following topics are dealt with: Detectors at COSY, major physics results at COSY, physics at external facilities, theoretical investigations, COSY operation and developments, preparations for FAIR, technical developments. (HSI)
2005-03-01
Feynmann variance-to-mean method
Energy Technology Data Exchange (ETDEWEB)
The Feynmann and other fluctuation techniques have been shown to be useful for determining the multiplication of subcritical systems. The moments of the counting distribution from neutron detectors is analyzed to yield the multiplication value. We present the methodology and some selected applications and results and comparisons with Monte Carlo calculations.
1985-01-01
Explosives detection The problem and prospects
Energy Technology Data Exchange (ETDEWEB)
Explosives molecules have a number of unique properties. These properties are discussed. They include low vapor pressures, electronegativity, ''stickiness,'' frangibility, and thermal instability. The program for developing an advanced explosives detector is described.
1984-07-01
UK PubMed Central (United Kingdom)
Objective. For the multislice CT (MSCT) systems with a larger number of detector rows, it is essential to employ dose-reduction techniques. As...Full Text Available
2008-01-01
Does DaYa-Bay Reactor Play an Important Role in Theta_{13} of Lepton Mixing (PMNS) Matrix ?
Reactor neutrinos play an important role in determining parameter theta_{13} in the lepton mixing (PMNS) matrix. Next important step on measuring PMNS matrix could be to build another reactor neutrino experiment in DaYa bay, China, to search the possible oscillations via sin^2 (2theta_{13}) and Delta m^2_{13}. We consider 4 different schemes for positions of three 8-ton detectors of this experiment, and simulate the results with respect to an array of assumed ''true'' values of physics parameters. Using three kinds of analysis method, we suggest a best scheme for DaYa-Bay which is to place a detector 2200m ~ 2500m symmetrically away from two reactors, and to put the other two detectors closer to their corresponding reactors respectively, almost at a 100m \\~ 200m distance. Moreover, with conservative assumption on the experimental technique, we construct series of allowed regions from our simulation results, and give ...
2004-01-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
Energy Technology Data Exchange (ETDEWEB)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...
2002-04-01
Direct digital radiography versus storage phosphor radiography in the detection of wrist fractures
International Nuclear Information System (INIS)
AIM: To define the value of digital radiography with a clinical flat panel detector system for evaluation of wrist fractures in comparison with state of the art storage phosphor radiography. MATERIAL AND METHODS: Hard copy images of 26 fractured wrist specimens were acquired with the same exposure dose on a state of the art storage phosphor radiography system and a clinical flat panel detector. Image features like cortical bone surface, trabecular bone, soft tissues and fracture delineation were independently analysed by 4 observers using a standardised protocol. Image quality ratings were evaluated with an analysis of variance (ANOVA). RESULTS: Flat panel detector radiographs were rated superior with respect to cortical and trabecular bone representation as well as fracture evaluation, while storage phosphor radiographs produced better soft tissue detail. CONCLUSION: In some of the observed image quality aspects, the ...
2002-04-01
The Daya Bay Neutrino Experiment is proposed to measure sin^2(2\\theta_{13}) to better than 0.01 at 90% C.L. in a three-year run. The experimental site, detector design, and background estimation are presented.
2006-01-01
International Nuclear Information System (INIS)
In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma discrimination. The scintillator is viewed by five RCA 48796 photo tubes. The ...
1992-03-16
International Nuclear Information System (INIS)
CEA-Valduc produces some radioactive waste (mainly alpha emitters). Legislation requires producers to sort their waste by activity and type of isotopes, and to package them in order to forward them to the appropriate reprocessing or storage facility. Our lab LMDE (laboratory for measurements on nuclear wastes and valuation) is in charge of the characterization of the majority of waste produced by CEA-Valduc. Among non-destructive methods to characterize a radioactive object, gamma-spectroscopy is one of the most efficient. We present to this conference the method we use to characterize nuclear waste and the system we developed to characterize our germanium detectors. The goal of this system is to obtain reliable numerical models of our detectors and calculate their efficiency curves. Measurements are necessary to checks models and improve them. These measurements are made on a bench using pinpoint sources ("1"3"3Ba, "1"5"2Eu) from 60 keV to ...
2009-06-07
Boron-Lined Neutron Detector Measurements
Energy Technology Data Exchange (ETDEWEB)
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. Reported here are the results of tests of a newly designed boron-lined ...
2009-11-02
Black holes as detectors of tachyons
International Nuclear Information System (INIS)
Tachyons fired into and absorbed by rotating black holes can violate the second and third laws of black hole physics. It is suggested that apparent break-downs of these laws in astrophysical black holes can indicate the existence of cosmic tachyons. (author).
Angular sensitivity distribution of detectors for BNCT
Energy Technology Data Exchange (ETDEWEB)
The research on the therapy of brain tumors and others by the thermal neutron irradiation using research reactors is to kill tumor cells by accumulating boron at a tumor part, and using {alpha} particles and {sup 7}Li generated by {sup 10}B(n, {alpha}){sup 7}Li reaction of thermal neutrons, which is known as boron neutron capture therapy (BNCT). In Japan Atomic Energy Research Institute, the medical irradiation facility was installed in the thermal neutron column of the JRR-2, and as of March, 1994, 22 cases of irradiation have been carried out. In order to monitor the variation of thermal neutron flux during irradiation, the real time measurement using a simultaneous monitor is carried out, but there is the variation of measured values in the Si semiconductor, p-n junction detector possibly due to its direction dependence. The experiment was carried out to quantity the direction dependence of the detector by using the neutron radiography ...
1995-03-01
Symbol Error Rates of Maximum-Likelihood Detector: Convex/Concave Behavior and Applications
Convexity/concavity properties of symbol error rates (SER) of the maximum likelihood detector operating in the AWGN channel (non-fading and fading) are studied. Generic conditions are identified under which the SER is a convex/concave function of the SNR. Universal bounds for the SER 1st and 2nd derivatives are obtained, which hold for arbitrary constellations and are tight for some of them. Applications of the results are discussed, which include optimum power allocation in spatial multiplexing systems, optimum power/time sharing to decrease or increase (jamming problem) error rate, and implication for fading channels.
2007-01-01
Response of track-etch dosemeters to environmental radon
Energy Technology Data Exchange (ETDEWEB)
The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).
1988-01-01
Real time neutron dosemeter response calculations
International Nuclear Information System (INIS)
The response of a real time neutron dosemeter using a thin LiF target sandwiched between tow parallel surface barrier semiconductor detectors is studied for different neutron distributions and different angles of incidence. Calculations of the response function defined for a simultaneous detection by the two detectors of the particles emitted when the reaction "6Li(n,t)#alpha# occurs in the target are fulfilled by geometrical considerations of the reaction kinematics and the differential cross section variations. Finally, the efficiency of the studied detection systems is analyzed for dosimetric uses. (author).
1996-04-01
Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia
Energy Technology Data Exchange (ETDEWEB)
Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The ...
2006-07-01
Proceedings of the technical exchange meeting on passive radon monnitoring
International Nuclear Information System (INIS)
The purpose of the meeting was to bring together a number of scientists active in the development and use of passive radon monitoring instrumentation, primarily activated charcoal detectors and alpha track detectors. Many of those present expressed a desire to receive copies of the viewgraphs and other materials presented. Most have supplied extended abstracts or complete reports. These materials are reproduced here as a Technical Measurements Center Report for the benefit of those attending the meeting and for others interested in passive radon monitoring. Individual papers were processed separately for the data base.
1987-09-21
Positron-Electron Pair Creation Near Threshold
Positron-electron pair creation near the threshold energy is extremely difficult to investigate by both experiments and theory. First test experiments were performed at the ILL to determine the cross sections for positron-electron pair creation near threshold using prompt {gamma}-rays from different targets after neutron capture and conventional radioactive sources. Pair creation was studied in a Ge detector, which simultaneously acted as sample and detector. First results are presented which show a significant deviation from theoretical values near threshold.
2009-01-28
Energy Technology Data Exchange (ETDEWEB)
It is built and tested a transition radiation detector (TRD) to discriminate positrons from protons in the balloon flight TS 93 experiment. It is presented the TRD performance using flight data obtaining a proton-positron rejection factor of the order of 10{sup -3}. During the 24 hour flight, the data in the momentum range 4-50 GeV/c are collected. Using the TRD together with the Silicon calorimeter, it is achieved an overall rejection factor of about 10{sup -5} of positron against the proton background over the entire momentum range.
1995-09-01
Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)
Energy Technology Data Exchange (ETDEWEB)
Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).
1993-01-01
New focal plane detector system for the broad range spectrometer
Energy Technology Data Exchange (ETDEWEB)
A focal plane detector system consisting of a vertical drift chamber, parallel plate avalanche counters, and an ionization chamber with segmented anodes has been installed in the Broad Range Spectrometer at the Holifield Facility at Oak Ridge. The system, which has been designed for use with light-heavy ions with energies ranging from 10 to 25 MeV/amu, has a position resolution of approx. 0.1 mm, a scattering angle resolution of approx. 3 mrad, and a mass resolution of approx. 1/60.
1984-01-01
Measurement of the inclusive Z production cross section with the CMS detector
First measurements of inclusive Z production cross sections in muon and electron decay channels at 7 TeV are presented for proton-proton collisions in the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). The comparison of the kinematic quantities as well as the studies of selection efficiencies demonstrate a good agreement between simulated events and current data. The measured inclusive cross section for Z($\\gamma^{*}$) production agrees with NNLO QCD cross section calculations and current parton distribution functions.
2010-01-01
Forward Physics with the CMS experiment at the Large Hadron Collider
multi-parton interactions and underlying event structure, $\\gamma$-mediated processes and luminosity determination, Monte Carlo tuning and even MSSM Higgs discovery in central exclusive production. In this article, the forward detector instrumentation around the CMS interaction point is described and the prospects for diffractive and forward physics using the CMS forward detectors are summarized. In addition, first observation of forward jets as well as early measurements of the forward energy flow in the pseudorapidity range $3.15
2010-01-01
Daya Bay reactor anti-neutrino experiment
International Nuclear Information System (INIS)
The Daya Bay Reactor Anti-Neutrino Experiment is a neutrino oscillation experiment designed to observe and measure the neutrino mixing angle ?13. The sensitivity goal is 0.01 in sin 22?13 at the 90% confidence level, a significant improvement over the current limit. This will be accomplished by measuring the relative rates and energy spectra of reactor electron antineutrinos with multiple detectors positioned at different baselines. Civil construction is currently under-way as detector designs and planning near completion. Commissioning activities should be completed by the end of 2010, followed by a three-year run.
2008-11-01
Daya Bay Neutrino Experiment: Goal, Progress and Schedule
Daya Bay Neutrino Experiment is dedicated to measuring the last unobserved neutrino mixing angle theta_13. The predicted precision on sin^2(2theta_13) is 0.01 at 90% confidence level. This document briefly reviews the measurement method and detector construction status. The first two anti-neutrino detectors' dry run result is also discussed. The Daya Bay near hall data taking is expected to commence in the summer of 2011 and the data taking of all of the three halls in the summer of 2012.
2011-01-01
Conceptual design of the ATLAS EM muon chamber support structures
The conceptual design of the support structures of the EM muon chambers is presented. On each side of the detector the EM chambers are arranged in four layers: one layer of MDTs and the three layers of TGCs. The chambers are mounted on four individual wheel structures per side. The four wheels are inclined by 1.23% and suspended from two longitudinal beams parallel to the beam axis. In order to allow for the opening of the ATLAS detector the wheels can be displaced longitudinally over a distance of 6 m. In addition individual wheels can be separated from each other by up to 1 m for maintenance purposes.
1998-01-01
Circuit design of PMT readout module for detector prototype of Daya Bay reactor neutrino experiment
International Nuclear Information System (INIS)
This paper describes the design of PMT readout module for detector prototype of Daya Bay Reactor Neutrino Experiment. According to the design requirements of the readout module, the basic structure of the readout module is discussed. This paper also discusses how to realize the charge measurement and time measurement and data processing using a high performance FPGA. The DAQ system including three readout modules and one trigger module are well commissioned and doing data taking now. (authors)
2006-10-21
Application of proportional counters in Polish medicine and agriculture
Energy Technology Data Exchange (ETDEWEB)
In the laboratory of Elementary Particle Physics and Detectors at the Faculty of Physics and Nuclear Techniques of the University of Mining and Metallurgy, research works on the development of proportional counters for the detection of X- and soft {gamma}-rays and {alpha}, {beta} particles have been carried out As a result of optimization of counters characteristic parameters such as: energy resolution, life time, count rate effect and temperature effect the operating stability has been reached and the elaborated detectors have been applied not only in research laboratories, but also in Polish industry, medicine and agriculture. Examples of above mentioned applications have been presented in the paper. (author). 7 refs, 7 figs, 1 tab.
1996-12-31
Air Shower Events of High-Energy Cosmic Rays Measured at Seoul, South Korea
The COsmic ray Research and Education Array (COREA) collaboration has installed an array of six detector stations at two high schools in and near Seoul, Korea for measurement of air-shower events from high-energy cosmic rays. Three stations are installed at each site, where each station consists of four plastic scintillation detectors covering an area of 2m2. In this presentation, we report the currenst status of the COREA project, describing the experimental equipment and measurement of coincident events.
2011-09-01
Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam
Energy Technology Data Exchange (ETDEWEB)
Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)
2003-03-01
A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment
Energy Technology Data Exchange (ETDEWEB)
The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))
1994-09-01
A new type active personal dosemeter with a solid state detector
International Nuclear Information System (INIS)
We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.
1988-04-01
A 40 GByte/s read-out system for GEM
Energy Technology Data Exchange (ETDEWEB)
The preliminary design of the read-out system for the GEM (Gammas, Electrons, Muons) detector at the Superconducting Super Collider is presented. The system reads all digitized data from the detector data sources at a Level 1 trigger rate of up to 100 kHz. A total read-out bandwidth of 40 GBytes/s is available. Data are stored in buffers that are accessible for further event filtering by an on-line, processor farm. Data are transported to the farm only as they are needed by the higher-level trigger algorithms, leading to a reduced bandwidth requirement in the Data Acquisition System.
1994-04-01
''SEPIO NUANCE DT'' digital mammography system
International Nuclear Information System (INIS)
In the past, the need for high quality images, i.e., very sharp and clear images, in mammography have prevented mammography equipment from being digitalized; however, recent advances in detection technology such as development of a high resolution digital X-ray detector have produced improvements in digital mammography. Digital mammography is expected to replace conventional film-screen mammography. We have developed a digital mammography system, named ''SEPIO NUANCE DT'', which is equipped with a direct conversion flat panel detector. The present paper describes the high basic performance and user-friendly functions of the system. (author)
2007-03-01
Energy Technology Data Exchange (ETDEWEB)
We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 {mu}m In{sub x}Al{sub y}Ga{sub 1-x-y}N alloy grown on 0.5-1.0 {mu}m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In{sub x}Al{sub y}Ga{sub 1-x-y}N detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In{sub x}Al{sub y}Ga{sub 1-x-y}N quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and ...
2000-08-07
Photoresponsivity of ultraviolet detectors based on In_xAl_yGa_1_-_x_-_yN quaternary alloys
International Nuclear Information System (INIS)
We describe the growth, fabrication, and characterization of an ultraviolet (UV) photoconductive detector based on In_xAl_yGa_1_-_x_-_yN quaternary alloy that is lattice matched to GaN. The detector consisted of 0.1 #mu#m In_xAl_yGa_1_-_x_-_yN alloy grown on 0.5-1.0 #mu#m GaN epilayer by metalorganic chemical vapor deposition. With varying indium concentration, the cut-off wavelength of the In_xAl_yGa_1_-_x_-_yN detectors could be varied to the deep UV range. The most important and intriguing result is that the responsivity of the In_xAl_yGa_1_-_x_-_yN quaternary alloy exceeded that of AlGaN alloy of a comparable cutoff wavelength by a factor of five. This makes the nitride quaternary alloy very important material for solar blind UV detectors applications particularly in the deep UV range where Al rich AlGaN alloys have problems with low quantum efficiency and cracks due in part to lattice mismatch with ...
2000-08-07
Wide bandgap collector III-V double heterojunction bipolar transistors
International Nuclear Information System (INIS)
This thesis is devoted to the study and development of Heterojunction Bipolar Transistors (HBTs) designed for high voltage operation. The work concentrates on the use of wide bandgap III-V semiconductor materials as the collector material and their associated properties influencing breakdown, such as impact ionisation coefficients. The work deals with issues related to incorporating a wide bandgap collector into double heterojunction structures such as conduction band discontinuities at the base-collector junction and results are presented which detail, a number of methods designed to eliminate the effects of such discontinuities. In particular the use of AlGaAs as the base material has been successful in eliminating the conduction band spike at this interface. A method of electrically injecting electrons into the collector has been employed to investigate impact ionisation in GaAs, GaInP and AlInP which has used the intrinsic gain of the devices to extract impact ...
Ultra high-speed (508 MHz) beam position digital feedback system
Energy Technology Data Exchange (ETDEWEB)
The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection and the change of computation parameters for specific bunch in ...
1997-02-01
Theoretical approach to initial growth kinetics of GaN on GaN(001)
British Library Electronic Table of Contents (United Kingdom)
We carried out theoretical analyses based on ab initio calculations incorporates in which free energy of the vapor phase is incorporated in order to determine the initial growth kinetics of c-GaN on GaN(001)-(4x1). The feasibility of the theoretical approach had been confirmed by calculations of Ga adsorption-desorption transition temperature and transition beam equivalent pressures on the GaAs(001)-(4x2)b2 surface in our previous work [Y. Kangawa, T. Ito, A. Taguchi, K. Shiraishi, T. Ohachi, Surf. Sci. 493 (2001) 178]. The results of calculations suggest that no Ga adsorption occurs on the initial surface under typical growth conditions but that a Ga adsorption site appears after N adsorption on GaN(001)-(4x1). That is, in the initial growth stage of c-GaN on GaN(001)-(4x1), a N-adsorbed ...
2007-01-01
Strain enhanced electron spin polarization observed in photoemission from InGaAs
International Nuclear Information System (INIS)
Electron spin polarization in excess of 70% has been observed in photoemission from a 0.1 #mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x #approx# 0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch, as confirmed by x-ray diffractometer measurements of the lattice parameter. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single band transition. Measurements made on a control sample of 1.14 #mu#m thickness, significantly larger than the critical thickness for pseudomorphic strain, show no polarization enhancement. These measurements represent the first observation of strain-enhanced electron spin polarization for ...
1991-05-06
Energy Technology Data Exchange (ETDEWEB)
Data are presented demonstrating very-short-wavelength (625 nm) room-temperature (300 K) continuous (cw) photopumped laser operation of In/sub 1-//sub y/(Al/sub x/Ga/sub 1-//sub x/)/sub y/P-In/sub 1-//sub y/ (Al/sub x/Ga/sub 1-//sub x/)/sub y/P quantum well heterostructures grown lattice matched (yapprox. =0.5) on a GaAs substrate via metalorganic chemical vapor deposition. In addition, 300 K pulsed laser operation (J/sub th/approx.10/sup 4/ A/cm/sup 2/, 625 nm) of diodes fabricated from the same crystal is described.
1988-04-18
International Nuclear Information System (INIS)
Thinning specimens to electron transparency for electron microscopy analysis can be done by conventional (2-4 kV) argon ion milling or focused ion beam (FIB) lift-out techniques. Both these methods tend to leave 'mottling' visible on thin specimen areas, and this is believed to be surface damage caused by ion implantation and amorphisation. A low energy (250-500 V) Argon ion polish has been shown to greatly improve specimen quality for crystalline silicon samples. Here we investigate the preparation of technologically important materials for nanoanalysis using conventional and lift-out methods followed by a low energy polish in a GentleMill"T"M low energy ion mill. We use a low energy, low angle (6-8 deg.) ion beam to remove the surface damage from previous processing steps. We assess this method for the preparation of technologically important materials, such as steel, silicon and GaAs. For these materials the ability to create specimens from specific sites, and ...
2006-02-22
International Nuclear Information System (INIS)
The dependence of the photoluminescent properties of In_0_._4_8(Al_yGa_1_-_y)_0_._5_2P alloys (0#<=#y#<=#0.5) on growth temperature and substrate misorientation off GaAs(100) has been studied. Samples were grown using low-pressure metalorganic vapor phase epitaxy. By studying the dependence of ordering behavior in InGaP as a function of substrate misorientation and growth temperature simultaneously, a very large range in low-temperature photoluminescence emission energy---135 meV---has been obtained. The photoluminescence linewidth exhibits a strong, continuous dependence on the extent of atomic ordering (the emission energy) in the alloys. The results indicate that inhomogeneity in the microstructure of the material (i.e., between ''ordered'' domains and the ''disordered'' matrix) is the dominant photoluminescence broadening mechanism. This investigation has allowed a significant optimization of the optical properties of these materials, including the ...
InAlGaP vertical cavity surface emitting lasers (VCSELs): Processing and performance
Energy Technology Data Exchange (ETDEWEB)
(Al{sub y}Ga{sub 1{minus}y}){sup 1{minus}x}In{sub x}P semiconductor alloys lattice-matched to GaAs are widely used in visible optoelectronic devices. One of the most recent developments in this area is the AlGaInP-based red vertical cavity surface emitting laser (VCSEL). These lasers, which employ AlGaInP active regions and AlGaAs distributed Bragg reflectors (DBRs), have demonstrated continuous-wave (CW) lasing over the 630--690 nm region of the spectrum. Applications for these lasers include plastic fiber data communications, laser printing and bar code scanning. In this paper, the authors present an overview of recent developments in the processing and performance of AlGaInP based VCSELs. This overview will include a review of the general heterostructure designs that have been employed, as well as the performance of lasers fabricated by both ion implantation and selective oxidation.
1997-06-01
High-efficiency solar cell and method for fabrication
A high-efficiency 3- or 4-junction solar cell is disclosed with a theoretical AM0 energy conversion efficiency of about 40%. The solar cell includes p-n junctions formed from indium gallium arsenide nitride (InGaAsN), gallium arsenide (GaAs) and indium gallium aluminum phosphide (InGaAlP) separated by n-p tunnel junctions. An optional germanium (Ge) p-n junction can be formed in the substrate upon which the other p-n junctions are grown. The bandgap energies for each p-n junction are tailored to provide substantially equal short-circuit currents for each p-n junction, thereby eliminating current bottlenecks and improving the overall energy conversion efficiency of the solar cell. Additionally, the use of an InGaAsN p-n junction overcomes super-bandgap energy losses that are present in conventional multi-junction solar cells. A method is also disclosed for fabricating the high-efficiency 3- or 4-junction solar cell by metal-organic chemical vapor deposition (MOCVD). ...
1999-08-31
High bandgap window layer for GaAs solar cells and fabrication process therefor
The specification describes a semiconductor solar cell and fabrication process therefor wherein a thin N-type gallium arsenide layer is deposited on a larger P-type substrate layer which is selected from the group of III-V ternary compounds consisting of aluminum phosphide antimonide, AlPSb, and aluminum indium phosphide, AlInP. P-type impurities are diffused from the substrate layer into a portion of the thin N-type gallium arsenide layer to form P-type region wherein which defines a PN junction in the thin gallium arsenide layer. Thus, the quantity of gallium arsenide required to provide this PN photovoltaic junction layer in the cell is minimized, and th P-type substrate serves as a high bandgap window layer for the cell. Such high bandgap of this window material is especially well suited for efficiently transmitting the blue spectrum of sunlight to the PN junction, thus enhancing the power conversion efficiency of the solar cell.
1979-05-29
Growth of single-crystal metastable semiconducting (GaSb)_1/sub -//sub x/Ge/sub x/ films
International Nuclear Information System (INIS)
Epitaxial metastable (GaSb)/sub 1-x/Ge/sub x/ alloys with compostions across the pseudobinary phase diagram have been grown on (100) GaAs substrates by multitarget rf sputtering. An essential feature allowing the growth of these metastable materials was low-energy ion bombardment of the growing film during deposition to enhance surface diffusion, promote mixing, and preferentially sputter incipient second-phase precipitates. Annealing experiments indicated that the metastable films exhibit good high-temperature stability and that they transform through a continuous series of GaSb-rich and Ge-rich phases in which the solute concentrations decrease until the equilibrium two-phase alloy is obtained. While the calculated free-energy difference between the single-phase metastable and equilibrium states is approx.18 meV, the measured activation barrier for the transformation is approx.3 eV. All films were p-type with room-temperature hole concentrations varying from ...
6180-01-01
Focused ion beam processes for high-T/sub c/ superconductors
International Nuclear Information System (INIS)
Focused ion beam (FIB) processes have been developed for Y--Ba--Cu--O superconductor films. A Y--Cu liquid metal ion source has been fabricated, using a Y_6_7 --Cu_3_3 eutectic alloy as the ion source. As-sputtered Y--Ba--Cu--O film etch rate ratios to GaAs(100) and Si(100) substrates are 0.28 and 1.4 for 130-keV Au"+ FIB ion etching, respectively. Y--Ba--Cu--O submicron patterns have been demonstrated by using FIB lithography and Cl_2 reactive ion beam etching. Moreover, a Y--Ba--Cu--O superconducting line with 4-#mu#m linewidth has been fabricated by annealing an as-sputtered Y--Ba--Cu--O line pattern. T/sub c/ control of Y--Ba--Cu--O film has been achieved by 200-keV Ne"+, using conventional ion implantation and 300 keV Si"+"+ FIB ion implantation.
A newly developed 220 Mbps free-space 4-ary pulse position modulation (PPM) direct detection optical communication system is described. High speed GaAs integrated circuits were used to construct the PPM encoder and receiver electronic circuits. Both PPM slot and word timing recovery were provided in the PPM receiver. The optical transmitter consisted of an AlGaAs laser diode (Mitsubishi ML5702A, lambda=821nm) and a high speed driver unit. The photodetector consisted of a silicon avalanche photodiode (APD) (RCA30902S) preceded by an optical interference filter (delta lambda=10nm). Preliminary tests showed that the self-synchronized PPM receiver could achieve a receiver bit error rate of less than 10(exp -6) at 25 nW average received optical signal power or 360 photons per transmitted information bit. The relatively poor receiver sensitivity was believed to be caused by the insufficient electronic bandwidth of the APD preamplifier and the poor linearity of the ...
1990-03-01
Diffusion mechanism of implanted Be in GaAs
Energy Technology Data Exchange (ETDEWEB)
The transient enhanced diffusion of low and high dose implanted beryllium in undoped gallium arsenide during post-implant rapid thermal annealing in the temperature range of 700-900 C for 60-240 s has been studied and successfully simulated by the kick-out diffusion model, involving singly positively charged Be interstitials and doubly positively charged Ga self-interstitials. Using the ''plus one'' approach for Ga interstitial generation after implantation with the local Ga interstitial sink concept as well as the appropriate initial and boundary conditions for involved mobile species, and taking into account Fermi-level and built-in electric field effects, the obtained partial differential equations have been solved numerically by means of an explicit finite difference method. The thermal equilibrium concentrations and the diffusivities of Be and Ga interstitials, all as a function of temperature, have been deduced from the fits of the experimental ...
2008-01-15
Defects induced by focused ion beam implantation in GaAs
Energy Technology Data Exchange (ETDEWEB)
The characteristics of defects induced by Si and Ga focused ion beam (FIB) implantation in n-GaAs have been investigated by means of deep-level transient spectroscopy (DLTS), C--V carrier profiling, and resistance measurements. The DLTS spectra of Si and Ga FIB implanted samples annealed at temperatures up to 500 /sup 0/C are apparently identical to one another and show three different electron traps with an activation energy between 0.25 and 0.6 eV. The resistance increases by more than five orders of magnitude by Si and Ga FIB implantation due to the induced defects. However, it is restored to initial values after annealing at 600 /sup 0/C, except for a sample of Ga implantation with a dose higher than 10/sup 14/ cm/sup 2/ . For annealing of induced defects, there are no intrinsic problems for FIB implantation with a dose lower than 10/sup 13/ cm/sup 2/ .
1988-05-01
Defects induced by focused ion beam implantation in GaAs
International Nuclear Information System (INIS)
The characteristics of defects induced by Si and Ga focused ion beam (FIB) implantation in n-GaAs have been investigated by means of deep-level transient spectroscopy (DLTS), C--V carrier profiling, and resistance measurements. The DLTS spectra of Si and Ga FIB implanted samples annealed at temperatures up to 500 "0C are apparently identical to one another and show three different electron traps with an activation energy between 0.25 and 0.6 eV. The resistance increases by more than five orders of magnitude by Si and Ga FIB implantation due to the induced defects. However, it is restored to initial values after annealing at 600 "0C, except for a sample of Ga implantation with a dose higher than 10"1"4 cm"2 . For annealing of induced defects, there are no intrinsic problems for FIB implantation with a dose lower than 10"1"3 cm"2.
CuBr blue light emitting electroluminescent thin film devices
British Library Electronic Table of Contents (United Kingdom)
Abstract Visible blue cathodoluminescence (CL), photoluminescence (PL), x-ray excited optical luminescence (XEOL) and electroluminescence (EL) via Zf free excitonic emission have been obtained from CuBr thin films deposited on glass, Cr coated glass, GaAs and Si substrates. In addition to the Zf emission several peaks corresponding to Cu+ emissions via 3d94s - d10 transitions were observed on the AC EL spectrum at 2.10, 2.7, 3.03, 3.07 and 3.80 eV. X-ray diffraction (XRD) measurements confirmed that the vacuum evaporated CuBr thin films grow preferentially with a (111) orientation irrespective of the substrate. While the AC voltage source was found to have no detrimental effects on CuBr thin films, cathodic deposition of Cu metal via electrolytic decomposition was observed under steady sta...
2011-01-01
Band parameters for III - V compound semiconductors and their alloys
International Nuclear Information System (INIS)
We present a comprehensive, up-to-date compilation of band parameters for the technologically important III - V zinc blende and wurtzite compound semiconductors: GaAs, GaSb, GaP, GaN, AlAs, AlSb, AlP, AlN, InAs, InSb, InP, and InN, along with their ternary and quaternary alloys. Based on a review of the existing literature, complete and consistent parameter sets are given for all materials. Emphasizing the quantities required for band structure calculations, we tabulate the direct and indirect energy gaps, spin-orbit, and crystal-field splittings, alloy bowing parameters, effective masses for electrons, heavy, light, and split-off holes, Luttinger parameters, interband momentum matrix elements, and deformation potentials, including temperature and alloy-composition dependences where available. Heterostructure band offsets are also given, on an absolute scale that allows any material to be aligned relative to any other. [copyright] 2001 American Institute of ...
2001-06-01
International Nuclear Information System (INIS)
The DLTS technique was employed to study deep defect centers in Si doped epitaxial layers of Al_0_._3_7Ga_0_._1_6In_0_._4_7P grown by MOCVD as a part of epitaxial structure GaAs/AlGaInP/GaAs on GaAs substrates. A high concentration of DX centers located in a region near the inverted interface GaAs/Al_0_._3_7Ga_0_._1_6In_0_._4_7P was found. The width of this region with the maximum DX center concentration ranges from 5 to 20 nm. By filling the DX centers in the whole region, the activation energy for electron emission was found to be 0.48 eV. However, it is shown for the first time, that the activation energy of the DX center increases with increasing the distance from the GaAs/Al_0_._3_7Ga_0_._1_6In_0_._4_7P inverted interface. A nonuniform of the DX center concentration on the wafers is also observed. The concentration varies in the range of 1#centre dot#10"1"7 cm"-"3 - 10"1"8 cm"-"3. (author)
An accurate high-speed single-electron quantum dot pump
International Nuclear Information System (INIS)
Using standard microfabrication techniques, it is now possible to construct devices that appear to reliably manipulate electrons one at a time. These devices have potential use as building blocks in quantum computing devices, or as a standard of electrical current derived only from a frequency and the fundamental charge. To date, the error rate in semiconductor 'tuneable-barrier' pump devices, those which show most promise for high-frequency operation, have not been tested in detail. We present high-accuracy measurements of the current from an etched GaAs quantum dot pump, operated at zero source-drain bias voltage with a single ac-modulated gate at 340 MHz driving the pump cycle. By comparison with a reference current derived from primary standards, we show that the electron transfer accuracy is better than 15 parts per million. High-resolution studies of the dependence of the pump current on the quantum dot tuning parameters also reveal possible deviations from a ...
2010-07-01
Stresses commonly present in AlGaAs/GaAs laser heterostructures were reduced using Molecular Beam Epitaxy grown Al/sub 0.3/Ga/sub 0.7/P/sub 0.01/As/sub 0.99/ cladding layers. The Al/sub 0.3/Ga/sub 0.7/P/sub 0.01/As/sub 0.99/ alloy was grown using an incident P/sub 2/ flux of roughly-equal1 x 10/sup 14//cm/sup 2/ indicating a sticking coefficient of 0.1 at a substrate temperature of 600 /sup 0/C. X-ray automatic Bragg angle control curvature measurements were used to monitor the residual heteroepitaxial stress. Broadened double crystal x-ray linewidths indicated the occurrence of alloy grading and broadened interfaces. The effects of P concentration and film thickness on stress and on the existence of a misfit dislocation grid are discussed.
1982-09-01
A singlet - triplet T_+ based qubit
International Nuclear Information System (INIS)
We theoretically model a nuclear-state preparation scheme that increases the coherence time of a two-spin qubit in a double quantum dot. The two-electron system is tuned repeatedly across a singlet-triplet level-anticrossing with alternating slow and rapid sweeps of an external bias voltage. Using a Landau-Zener-Stueckelberg model, we find that in addition to a small nuclear polarization that weakly affects the electron spin coherence, the slow sweeps are only partially adiabatic and lead to a weak nuclear spin measurement and a nuclear-state narrowing which prolongs the electron spin coherence. This resolves some open problems brought up by a recent experiment. We also show that the electronic two-spin states singlet and triplet T_+ are promising candidates for the implementation of a qubit in GaAs double quantum dots (DQD). A coherent superposition of the two-spin states is obtained by finite time Landau-Zener-Stueckelberg interferometry and the single qubit ...
2010-03-21
0--30 keV low-energy focused ion beam system
Energy Technology Data Exchange (ETDEWEB)
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga/sup +/ ion beams <0.3 ..mu..m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga/sup +/ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
1988-05-01
0--30 keV low-energy focused ion beam system
International Nuclear Information System (INIS)
Low-energy focused ion beam (FIB) is a useful tool for shallow doping, gas-assisted etching, and other uses to minimize substrate damage in semiconductor device fabrication. The possibility to form a finely FIB of low energy under 1 keV was suggested in the investigations on the retarding mode in electron optical systems. The abilities of the simplest type of retarding mode FIB column are examined here. The optical properties are calculated for the corresponding model and some images are observed with Ga"+ ion beams <0.3 #mu#m in diameter for beam energies, 10, 5, and 1 keV, using a retarding mode one-lens FIB system. 1-keV and 100-eV Ga"+ FIB was implanted to Ga/As substrate, and the defects are analyzed by deep-level transient spectroscopy. The defect concentration for 100 eV was < (1)/(5) that for 1000 keV.
Thallium-technetium subtraction parathyroid imaging in patients having previous parathyroid surgery
International Nuclear Information System (INIS)
Parathyroid imaging based on the principle of differential uptakes of Tc-99m and T1-201 in the anterior neck to localize parathyroid (PT) disease has been reported with widely varying results. To evaluate the usefulness of this method, we have performed PT imaging on 47 patients prior to exploratory surgery for PT disease. Using pinhole collimation and digital acquisition, a 50k count image of the thyroid was obtained 20 minutes after injection of 1mCi99m Tc-pertechnetate. Then a lmCi dose of Tl-201 chloride was injected and a series of images acquired for 30 minutes at 30 sec/image. Raw data was spatially filtered and normalized by summing sufficient T1-201 images to equal the Tc-99m image scale of maximum cts/pixel. Image subtraction (Tl-Tc) gave the final PT image. Of 10 pts who had previous neck exploration, all had PT pathology accurately localized by preoperative scanning (7=single adenoma, 2=single hyperplastic gland, 1=two hyperplastic glands). In two ...
1985-06-02
Reduced "9"9"mTc labelled NCA-95/CEA-antibody uptake in liver due to gentle antibody reconstitution
International Nuclear Information System (INIS)
The influence of reconstituting a murine monoclonal IgG_1 antibody kit with pertechnetate Tc99m on antibody distribution in the liver, spleen and sternal bone marrow of patients was examined. The "9"9"mTc-labelled antibody used is directed against non-specific cross-reacting antigen (NCA-95) and carcinoembryonic antigen (CEA) and has been successfully applied for imaging tissue inflammation and bone marrow scanning. Radioactivity uptake was determined in the liver, spleen, bone marrow and a precordial background region in a consecutive series of 25 patients, examined with an antibody preparation, routinely radiolabelled according to the manufacturer's recommendations and in 14 patients, in whom the antibody was reconstituted with special care, avoiding bubble formation and dropping of buffer into the antibody-containing vial. Gentle compared with routine antibody reconstitution caused a highly significant reduction of the antibody uptake in the liver, as determined by count densities, ...
Measuring q sub 0 using supernovae at z approx 0. 3
Energy Technology Data Exchange (ETDEWEB)
The measurement of q{sub o} is extremely important for understanding the quantity of matter in our universe. The measurement of q{sub o} using supernovae of type Ia as standard candles is appealing because it requires less modeling than other methods using galaxies. The challenge with using supernovae to measure q{sub o} is in finding enough of them. In order to find supernovas, we have constructed a very popular f/1 camera for the 3.9m Anglo-Australian Telescope. The camera uses reducing optics that put a 17 in. {times} 17 in. field on a 1024 {times} 1024 pixel Thomson CCD. Using this system, we image to 23rd magnitude in five minutes. We have developed a software package that uses image subtraction to find supernovae that are approximately magnitude 22.4 or brighter in these images. One field can be processed every 6.6 minutes on a relatively unloaded VAX 6000-6510. We estimate that this system should find one supernova in every 105--139 images (about two nights ...
1992-07-01
We will present the first astronomical images taken with MIRSI (Mid-InfraRed Spectrometer and Imager). First light for MIRSI is scheduled for December 2001. MIRSI is a mid-infrared camera system recently completed at Boston University that has both spectroscopic and imaging capabilities. The camera utilizes a new 320x240 Si:As IBC array developed for ground-based astronomy by Raytheon/SBRC. MIRSI offers a large field of view (1.6 arcmin x 1.2 arcmin at the IRTF with a pixel scale of 0.3 arcsec), diffraction-limited spatial resolution, complete spectral coverage over the 8-14 micron and 17-26 micron atmospheric windows for both imaging (discrete filters and CVF) and spectroscopy (10 and 20 micron grisms), and high sensitivity (expected 1-sigma point source sensitivities of 5 and 20 mJy at 10 and 20 microns, respectively, for on-source integration time of 30 seconds). This system offers the unique ability to acquire both spectra and high-resolution, multi-wavelength ...
2001-12-01
Families of ellipsoidal stellar systems adn the formation of dwarf elliptical galaxies
International Nuclear Information System (INIS)
Core radii and central surface brightnesses of bulges and elliptical galaxies are measured using CCD photometry obtained with the Canada-France-Hawaii Telescope (scale = 0''.22 pixel"-"1; seeing = 0''.45--1''.0 FWHM). The correlations between core parameters are derived and compared for ellipticals, bulges, dwarf spheroidal galaxies, dwarf irregular galaxies, and globular clusters. The results are as follows. 1. Ihe data confirm the existence of well-defined correlations between the core parameters of elliptical galaxies. More luminous ellipticals have larger core radii r/sub c/ and lower central surface brightnesses #mu#/sub 0v/. Galaxies with larger core radii have larger central velocity dispersions. The small, bright core of M32 is normal for a galaxy of M/sub B/ = -15.2. Radio ellipticals and brightest cluster galaxies satisfy the correlations. 2. The bulges of disk galaxies are basically similar to elliptical galaxies. Their cores have slightly smaller r/sub ...
FABRICATION OF BISMUTH NANOWIRE DEVICES USING FOCUSED ION BEAM MILLING
International Nuclear Information System (INIS)
In this work, a focused ion beam (FIB) milling process has been developed to fabricate 50 nm Bi nanowire and transistor structures using FEI-200 dual beam FIB system. For the fabrication, 50 nm bismuth film was thermally evaporated through EBL patterned PMMA windows onto SiO_2 substrates with pre-defined contact pads. Bi nanowire widths ranging from 30 nm to 100 nm have been successfully fabricated by milling out unwanted areas using 30 KeV Ga+ ion beam. A single-pixel-line ion beam blanking technique has been utilised to fabricate Bi nanowire as small as 30 nm in diameter and few micrometers long. In order to form good ohmic contacts for sub 50 nm bismuth nanowires, a drill-and-fill process has been developed using FIB to sputter away the surface oxide of bismuth after the in-situ platinum nanowire contacts deposition. To our knowledge, this is the first time a focused ion beam process has been used to fabricate bismuth nanowire. The fabricated Bi nanowires were ...
2009-07-23
Digital subtraction angiography with scanning lazer stimulated luminescence
International Nuclear Information System (INIS)
Fuji Computed Radiography (FCR) utilizes imaging plates of scanning lazer stimulated luminescence. FCR can be used for intravenous digital subtraction angiography (IVDSA) and for intraarterial studies because of tis high contrast and spatial resolution. Pixel size of the imaging plates for angiography is 0.2 mm. Experimentally, it could demonstrate a vessel 1 mm in diameter with a contrast of 0.1, when opacified with a contrast medium of 3 % iodine concentration, and could image a vessel 3 mm in diameter with contrast of 0.1, when opacified with 1 % contrast medium. A 20 % stenosed portion of a vessel 3 mm in diameter was identified when opacified with 3 % contrast medium, and a 20 % stenosed portion of a vessel 2 mm in diameter was identified when opacified with 10 % contrast medium. In 105 IVDSA examinations of 75 patients, FCR was superior to Digital Fluorography (DF) in spatial resolution, size of examination field, dynamic range and exposure dose. Also noted ...
1985-01-01
Comparison of NLCD with NWI Classifications of Baldwin and Mobile Counties, Alabama
An assessment of the accuracy of National Land Cover Data 2001 as compared to National Wetlands Inventory mapping of Mobile and Baldwin Counties conducted by the U.S. Geological Survey's (USGS) National Wetlands Research Center (NWRC). Both classifications were checked against stratified randomly selected ground-based sites and with each other to compare the accuracy of the NLCD with NWI classification methods. For this accuracy comparison, numerous visits were made by photointerpreters to the Mobile Bay area to establish signatures for the modified NWI mapping. After all of the quadrangles in Baldwin and Mobile Counties were mapped, an accuracy assessment of those maps was conducted by field-checking the mapped classes with ground-based check sites. These same sites were used to check the accuracy of the NLCD and also as the basis for cross-walking the NLCD and NWI classification systems for direct comparison of the two methods. This accuracy assessment is dependent on a methodology ...
2009-01-01
Energy Technology Data Exchange (ETDEWEB)
Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with {sup 131}I-labeled intact CEA 102 or its F(ab'){sub 2}. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of {sup 131}I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in ...
1992-04-01
International Nuclear Information System (INIS)
Anti-carcinoembryonic antigen monclonal antibody (MAb) CEA 102 was produced by immunization with purified CEA and the specific accumulation of radiolabeled CEA 102 in colorectal cancers was investigated by autoradiography of sugical specimens using Fuji Computed Radiography (FCR). Five patients with colorectal cancer were injected intravenously with "1"3"1I-labeled intact CEA 102 or its F(ab')_2. Primary tumor and liver metastases were successfully detected by external scanning with a gamma camera in 4 cases. Autoradiographic study of the surgical specimens using FCR showed predominant localization of "1"3"1I-labeled CEA 102 in primary tumors and liver metastases in all cases. Even a small liver metastasis (0.5 cm) was clearly visualized in the autoradiogram by FCR. The pixel distribution curves of the density of the respective tissues in the autoradiograms by FCR showed the heterogeneity of the distribution of administreted radiolabeled MAb in individual tumors, ...
1992-01-01
Amplification of Inaccuracies of Initial Conditions in Cosmological Simulations
Cosmological N-body and hydrodynamic simulations start with a realization of a random density fluctuation field representing a cosmological model at an early epoch. The density field is often replaced by a set of particles whose positions and velocities are set to conform to the desired density field. Each particle represents a cloud of huge number of real particles. Positions and velocities of particles are subsequently integrated by various numerical codes. We have simulated a set of collisionless collapses of Gaussian density peaks by using the PM and P(3) M codes. We find that in cosmological simulations the physics at scales below the mean particle separation(MPS) is dominated by inaccuracies in describing the initial density field, and cannot be studied even by the high force-resolution codes. Since density fluctuations are ill-defined at scales smaller than MPS, it is desirable not to amplify this problem during the evolution. The P(3) M code is shown to divergently amplify the ...
1997-01-01
Energy Technology Data Exchange (ETDEWEB)
The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first ...
1988-08-01
Energy Technology Data Exchange (ETDEWEB)
The subcriticality of two interacting solution tanks was determined using /sup 252/Cf-source-driven neutron noise analysis methods. These experiments were the first test of this method for an interacting system with materials (in this case, uranyl nitrate) typical of nuclear materials in processing plants. The experiments were performed to test the conclusions from previous interaction experiments with uranium metal discs for a fissile system with moderation, and to provide data to test theoretical models for coupled systems. The uranium metal experiments showed that the subcritical neutron multiplication factor, k/sub eff/, could be determined using point kinetics without any correction for spatial effects from measurements with the source and detectors located adjacent to the same cylinder, whereas for source-detector configurations with either the source and/or detectors adjacent to different cylinders, a model which ...
1986-01-01
International Nuclear Information System (INIS)
An experiment was performed with a mock-up of the core of the Fast Flux Test Facility (FFTF) reactor to evaluate three reactivity measurement methods for application to liquid-metal fast breeder reactors (LMFBR): modified source multiplication measurements with the low-level flux monitor for refueling (35 dollars subcritical) of FFTF, noise analysis to 35 dollars subcritical, and inverse kinetics rod drop to 12 dollars subcritical. To investigate the spatial dependence of these measurement methods and to resolve discrepancies previously reported, detectors were placed in the core, reflector, and radial shield, and experimental data were collected with the reactivity at near delayed criticality to 35 dollars subcritical. Conclusions from this experiment are the following. Low-level flux monitors in the shield of the FFTF will be adequate for reactivity surveillance during refueling, using the modified source multiplication method calibrated near critical by an ...
Nuclear radiation detectors on II-VI compounds
International Nuclear Information System (INIS)
Nuclear radiation detectors in integral execution were produced by successive epitaxial growth from vapor phase of Zn Te and Cd Se thin layers onto scintillating Zn Se (Te) crystals. The irradiation of combined Zn Se (Te) - Zn Te - Cd Se detectors by Cu_K_a X-rays leads to the appearance of photoreceiver e.m.f., which tends to saturation with the increase of X-ray radiation dose reaching the value of 0.34-0.40 V at 200 R/min. The short circuit current dependence of irradiation dose power is linear. The matching factor for detectors with Zn Te-Cd Se photoreceivers with different doping levels is 0.68-0.92. The absolute monochromatic sensitivity is 0.32-0.35 m A/m W at a quantum efficiency 0.58-0.61 and a time constant 2 x 10"-"4 s. The calculated dose sensitivity for Zn Se(Te)-Zn Te-Cd Se combined detectors at the irradiation with X-rays having effective energy 8.86 keV gives the value 3.9 x 10"-"7 ...
1993-10-13
HALO - the helium and lead observatory for supernova neutrinos
Energy Technology Data Exchange (ETDEWEB)
The Helium and Lead Observatory (HALO) is a supernova neutrino detector under development for construction at SNOLAB. It is intended to fulfill a niche as a long term, low cost, high livetime, and low maintenance, dedicated supernova detector. It will be constructed from 80 tonnes of lead, from the decommissioning of the Deep River Cosmic Ray Station, and instrumented with approximately 384 meters of {sup 3}He neutron detectors from the final phase of the SNO experiment. Charged- and Neutral-Current neutrino interactions in lead expel neutrons from the lead nuclei making a burst of detected neutrons the signature for the detection of a supernova. Existing neutrino detectors are mostly of the water Cerenkov and liquid scintillator types, which are primarily sensitive to electron anti-neutrinos via charged-current interactions on the hydrogen nuclei in these materials. By contrast, the large neutron ...
2008-11-01
Considerations for the next Compton telescope mission
International Nuclear Information System (INIS)
A high resolution Compton telescope has been identified by the Gamma Ray Astronomy Program Working Group (GRAPWG) as the highest priority major mission in gamma ray astrophysics following GLAST. This mission should provide 25-100 times improved sensitivity, relative to CGRO and INTEGRAL, for MeV gamma ray lines. It must have good performance for narrow and broad lines and for discrete and diffuse emissions. Several instrumental approaches are being pursued to achieve these goals. We discuss issues relating to this mission including alternative detector concepts, instrumental configurations, and background reduction techniques. We have pursued the development of position-sensitive solid-state detectors (Ge, Si) for a high spectral resolution Compton telescope mission. A #approx#1 m2 germanium Compton telescope of position-sensitive germanium detectors was the basis for one of the GRAPWG concepts. Preliminary Monte Carlo ...
2000-04-12
Boron-Lined Multichamber and Conventional Neutron Proportional Counter Tests
Energy Technology Data Exchange (ETDEWEB)
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in RPMs. These technologies are: 1) Boron trifluoride (BF3)-filled proportional ...
2010-09-07
Basic study of entire whole-body PET scanners based on the OpenPET geometry
International Nuclear Information System (INIS)
A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, ...
2010-09-01
First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of naturally-occurring alpha-emitting background. The drift velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction and energy spectra were used to identify alpha particles from the decay of Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218 progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.
2007-01-01
Thermal Design and Performance of the Gamma-Ray Spectrometer for the MESSENGER Spacecraft
Energy Technology Data Exchange (ETDEWEB)
A gamma-ray spectrometer (GRS) has been built and delivered to the Mercury MESSENGER spacecraft which launched on August 3, 2004, from Cape Canaveral, Florida. The GRS, a part of seven scientific instruments on board MESSENGER, is based on a coaxial high-purity germanium detector. Gamma-ray detectors based on germanium have the advantage of providing excellent energy resolution, which is critical to achieving the science goals of the mission. However, germanium has the disadvantage that it must operate at cryogenic temperatures (typically {approx}80 K). This requirement is easy to satisfy in the laboratory but difficult near Mercury, which has an extremely hot thermal radiation environment. To cool the detector, a Stirling cycle mechanical cooler is employed. In addition, radiation and conduction techniques a are used to reduce the GRS heat load. Before delivering the flight sensor, a complete thermal prototype was built ...
2004-10-13
TIARA: A large solid angle silicon array for direct reaction studies with radioactive beams
International Nuclear Information System (INIS)
A compact, quasi-4? position sensitive silicon array, TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the ?-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The 14N(d,p)15N reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the 15N ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. Transferred l-values are in ...
2010-03-11
Energy Technology Data Exchange (ETDEWEB)
Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to [sup 47]V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of [sup 28]Al through three different entrance channels. Angular distributions are shown for different mass channels of the [sup 29]Si+[sup 27]Al reaction at E[sub lab] = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the [sup 24]Mg+[sup 24]Mg reaction; cross sections for binary fragment emission are shown for E[sub lab] = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.
1992-01-01
Research in heavy-ion nuclear physics. Annual progress report, May 1, 1992--April 30, 1993
Energy Technology Data Exchange (ETDEWEB)
Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to {sup 47}V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of {sup 28}Al through three different entrance channels. Angular distributions are shown for different mass channels of the {sup 29}Si+{sup 27}Al reaction at E{sub lab} = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the {sup 24}Mg+{sup 24}Mg reaction; cross sections for binary fragment emission are shown for E{sub lab} = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.
1992-01-01
Radioanalytical methods of rare earth element determination
International Nuclear Information System (INIS)
Instrumental neutron activation analysis (INAA) and radionuclide X-ray fluorescence analysis (RXFA) were used for the determination of rare earth elements. For INAA, solution obtained by sample decomposition was dripped onto filter paper, enclosed and sealed into a polyethylene foil. The sample was activated in reactor WWR-S over a period of 4 to 6 hours with a neutron fluence of 10"1"3cm"-"2. Gamma radiation measurement was carried out with a planar and a coaxial HP-Ge detector in three decay periods. La, Ce, Nd, Sm, Eu, Gd, Tb, Ho, Tm, Yb and Lu were determined. The advantage of the method is its accuracy and high sensitivity, the disadvantage is the time-consuming analysis. The RXFA method was used as a rapid and operative method for the analysis of loose ore samples, aqueous and organic solutions of rare earth elements. For exciting X-ray radiation, "2"4"1Am was used and the radiation of K-lines was detected with a planar Si(Li) detector. ...
1989-06-01
Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation
International Nuclear Information System (INIS)
In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light yield and light ...
1992-10-25
National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards
International Nuclear Information System (INIS)
As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible spectral features of nuclear materials. ...
2009-12-16
Modeling of Fission Neutrons as a Signature for Detection of Highly Enriched Uranium
Energy Technology Data Exchange (ETDEWEB)
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the target and detector. The resulting neutrons ...
2004-03-09
MicroDiffraction in the Scanning Electron Microscope (SEM)
The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits high magnification ...
1997-12-31
Micro-strip metal foil detectors for the beam profile monitoring
Energy Technology Data Exchange (ETDEWEB)
The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.
2005-07-01
Energy Technology Data Exchange (ETDEWEB)
The progress made in particle detection, particularly the design of multi-detectors, like INDRA, that cover a solid angle of almost 4{pi}, have given a new impetus to heavy ion collisions. These detectors are demanding for an efficient way of selecting events that have a common history or similar features, for instance the events representing the de-excitation of a unique emitter. The problem is to find the adequate variable on which the discrimination can be based. Different methods are proposed in this work, the common point is that they require efficient models to reproduce and analyse experimental data in order to apprehend the equation of state of nuclear matter. Most of these models are based on the numerically solving of the nuclear Boltzmann equation. The application to the Ni + Ni reaction with an energy ranging from a few A.MeV to more than 50 A.MeV illustrates this work. (A.C.)
2005-11-15
Launch of the Space experiment PAMELA
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false triggers coming from the satellite. In ...
2007-01-01
Interim cryo-cooler/detector report
Energy Technology Data Exchange (ETDEWEB)
This report describes development of an electronic system designed to reduce vibration generated by a cryocooler. The diminished vibration makes it practical to use the active cooler to extract heat from a portable gamma ray detector instrument. The system was developed for a Sunpower cryocooler with an integrated counterbalance mass. The overall momentum cancellation approach is also applicable to other similar cryocoolers. The cancellation system is an assembly of several components tailored to accomplish the required vibration reduction with minimum power consumption and volume. It is designed to be powered by a 18--32 Volt battery. Up to ten harmonics of the 58.65 Hz drive frequency are controlled. In addition to the vibration cancellation, the electronic system produces the drive signal for the cryocooler and regulates the cooler temperature. The system employs a sinusoidal drive to reduce the amount of higher harmonic vibration. A digital signal processor ...
1995-04-19
Energy Technology Data Exchange (ETDEWEB)
Indoor and soil gas Radon ({sup 222}Rn) concentration measurements were accomplished in two stages in Sivas, a central eastern city in Turkey. In the first stage, CR-39 passive nuclear track detectors supplied by the Turkish Atomic Energy Authority (TAEA) were placed in the selected houses throughout Sivas centrum in two seasons; summer and winter. Before the setup of detectors, a detailed questionnaire form was distributed to the inhabitants of selected houses to investigate construction parameters and properties of the houses, and living conditions of inhabitants. Detectors were collected back two months later and analysed at TAEA laboratories to obtain indoor {sup 222}Rn gas concentration values. In the second stage, soil gas {sup 222}Rn measurements were performed using an alphameter near the selected houses for the indoor measurements. Although {sup 222}Rn concentrations in Sivas were quite low in relation with the ...
2010-11-15
International Nuclear Information System (INIS)
In an existent emergency reactor core cooling device, if a ruptures should occure in a pipeline of a gravitational dropping type reactor core cooling system pool (GDCS) due to some or other causes, a portion of GDCS pool water was flown out of the ruptured port and could not be used for reactor core cooling. Then, a difference pressure detector is disposed to a GDCS pipeline at the inlet of a reactor pressure vessel. When it is judged by the detector, that coolants flow to the outside of the injection pipeline, an injection value disposed to the GDCS pipeline is closed by the difference pressure signal. Even if a rupture should occur on the side of the pressure vessel at downstream to the check value of the GDCS pipeline, since backflow is caused at the pressure container inlet of the GDCS pipeline with the rupture port, the rupture is detected by the difference pressure detector to close the injection valve. Therefore, ...
1990-10-29
Edge filter and fringe imaging for laser Doppler wind speed measurement
Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of ...
1997-08-01
Construction and Calibration of the Laser Alignment System for the CMS Tracker
The CMS detector (Compact Muon Solenoid) is under construction at one of the four proton-proton interaction points of the LHC (Large Hadron Collider) at CERN, the European Organization for Nuclear Research (Geneva, Switzerland). The inner tracking system of the CMS experiment consisting of silicon detectors will have a diameter of 2.4 m and a length of 5.4 m representing the largest silicon tracker ever. About 15000 silicon strip modules create an active silicon area of 200 m2 to detect charged particles from proton collisions. They are placed on a rigid carbon fibre structure, providing stability within the working conditions of a 4 T solenoid magnetic field at ?10oC. Knowledge of the position of the silicon detectors at the level of 100 ?m is needed for an efficient pattern recognition of charged particle tracks. Metrology methods are used to survey tracker subdetectors and the integrated Laser Alignment System (LAS) ...
2006-01-01
Polarization measurements in the X-ray and gamma-ray energy range can provide crucial information on massive compact objects such as black holes and neutron stars. The Polarized Gamma-ray Observer (PoGO) is a new balloon-borne instrument designed to measure polarization from astrophysical objects in the 30-100 keV range, under development by an international collaboration with members from United States, Japan, Sweden and France. To examine PoGO's capability, a beam test of a simplified prototype detector array was conducted at the Argonne National Laboratory Advanced Photon Source. The detector array consisted of seven plastic scintillators, and was irradiated by polarized photon beams at 60, 73, and 83 keV. The data showed a clear polarization signal, with a measured modulation factor of $0.42 \\pm 0.01$. This was successfully reproduced at the 10% level by the computer simulation package Geant4 after modifications to its implementation of ...
2005-01-01
Application of a finite element method to leak before break (LBB) of a heat exchanger
International Nuclear Information System (INIS)
The leak before break (LBB) concept is difficult to apply to a structure with a thin tube that is immersed in a water environment. A heat exchanger in a nuclear power plant is such a structure. The present paper addresses an application of the LBB concept to a heat exchanger in a nuclear power plant. The minimum leaked coolant amount containing the radioactive material which can activate the radiation detector device installed near the heat exchanger is assumed. The postulated initial flaw size that cannot grow to the critical flaw size within the time period to activate the radiation detector is justified. In this case, the radiation detector can activate the warning signal caused by coolant leakage from initially postulated flaws of the heat exchanger. The nuclear plant can safely shutdown when this occurs. Since the postulated initial flaw size can not grow to the critical flaw size, the structural integrity of the heat ...
2003-08-17
Accelerator related background in the CMS detector at LHC
International Nuclear Information System (INIS)
Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative contribution of accelerator ...
A Risk-Based Sensor Placement Methodology
Energy Technology Data Exchange (ETDEWEB)
A risk-based sensor placement methodology is proposed to solve the problem of optimal location of sensors or detectors to protect population against the exposure to and effects of known and/or postulated chemical, biological, and/or radiological threats. Risk is calculated as a quantitative value representing population at risk from exposure against standard exposure levels. Historical meteorological data are used to characterize weather conditions as the frequency of wind speed and direction pairs. The meteorological data drive atmospheric transport and dispersion modeling of the threats, the results of which are used to calculate risk values. Sensor locations are determined via an iterative dynamic programming algorithm whereby threats captured or detected by sensors placed in prior stages are removed from consideration in subsequent stages. In addition to the risk-based placement algorithm, the proposed methodology provides a quantification of the marginal ...
2008-10-01
Website Policies and Important Links Comments
WorldWideScience.org is maintained by the U.S. Department of Energy's
Office of Scientific and Technical Information as the Operating Agent
for the WorldWideScience Alliance.
