WorldWideScience
1

Femtosecond Laser Passivation of GaAs Detector Material  

Science.gov (United States)

... The approach is to perform noise spectral density measurements and selected materials structure measurements on GaAs detector materials, with ...

2008-06-07

2

Temperature dependence of the performance of ultraviolet detectors  

Energy Technology Data Exchange (ETDEWEB)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause ...

2003-08-21

3

Temperature dependence of the performance of ultraviolet detectors  

International Nuclear Information System (INIS)

We present the results of a comprehensive study of the temperature dependences of the quantum efficiency for ultraviolet detectors based on GaAs, GaP and 4H--SiC Schottky structures, and on Si, GaAs p-n structures. For ultraviolet detectors based on Schottky structures, the quantum efficiency increases with increasing temperature for all photon energies, even including the semiconductor intrinsic absorption region. On the other hand, for ultraviolet detectors based on p-n structures, the quantum efficiency is practically temperature independent in the semiconductor intrinsic absorption region. The change in the quantum efficiency for the GaAs and Si detectors is less than 0.01% per degree. To explain the measurements, a variable trap occupancy model is presented. Subsurface imperfections of the semiconductor cause ...

2003-08-21

4

GaAs Blocked-Impurity-Band Detectors for Far-Infrared Astronomy  

Energy Technology Data Exchange (ETDEWEB)

High-purity and doped GaAs films have been grown by Liquid-phase epitaxy (LPE) for development of a blocked impurity band (BIB) detector for far-infrared radiation. The film growth process developed has resulted in the capability to grow GaAs with a net active impurity concentration below 1 x 10{sup 13} cm{sup -3}, ideal for the blocking layer of the BIB detector. The growth of n-type LPE GaAs films with donor concentrations below the metal-insulator transition, as required for the absorbing layer of a BIB detector, has been achieved. The control of the donor concentration, however, was found to be insufficient for detector production. The growth by LPE of a high-purity film onto a commercially grown vapor-phase epitaxial (VPE) n-type GaAs doped absorbing layer resulted in a BIB device that showed a significant reduction ...

2004-12-21

5

GaAs detector optimization for different medical imaging applications  

International Nuclear Information System (INIS)

We have investigated the detection performance of GaAs detectors made with different thickness and contact geometries. A comparison is made between these detection capabilities and the imaging requirements for the following medical applications: digital mammography, digital chest radiography and nuclear medicine. Experimental results and preliminary images are presented and discussed. (author)

1999-09-11

6

Design of a GaAs X-ray imaging sensor with integrated HEMT readout circuitry  

CERN Document Server

A new monolithic semi-insulating (SI) GaAs sensor design for X-ray imaging applications between 10-100keV has been proposed. Monolithic pixel detectors offer a number of advantages over hybrid bump-bonded detectors, such as high device yield, low costs and are easier to produce large scale arrays. In this thesis, an investigation is made of the use of a SI GaAs wafer as both a detector element and substrate for the epitaxially grown High Electron Mobility Transistors (HEMTs). The design of the HEMT transistors, optimised for this application, were produced with the aid of the Silvaco 'Virtual Wafer Fab' simulation package. It was determined that the device characteristics would consist of a small positive threshold voltage, a low off-state drain current and high transconductance. The final HEMT transistor design, that would be integrated to a pixel detector, had ...

2002-01-01

7

Deep-level defects and numerical simulation of radiation damage in GaAs solar cells  

Energy Technology Data Exchange (ETDEWEB)

A review of the deep-level defects observed in both electron- and proton-irradiated GaAs solar cells is presented. Studies of the effects of periodic and continuous thermal annealing on the radiation-induced electron and hole traps and the recombination parameters in GaAs solar cells were made for a wide range of electron and proton energies, fluence, annealing temperature and annealing time. A refined model for numerical simulations of the displacement damage was developed for computing the defect density and the cell parameters in the electron- and proton-irradiated GaAs solar cells. Excellent agreement was obtained between the calculated values and the experimental data for the proton-irradiated GaAs solar cells. (orig.).

1991-09-01

8

Surface-plasma interactions in GaAs subjected to capacitively coupled RF plasmas  

CERN Document Server

Surface compositional changes in GaAs due to RF plasmas of different gases have been investigated by XPS and etch rates were measured using AFM. Angular Resolved XPS (ARXPS) was also employed for depth analysis of the composition of the surface layers. An important role in this study was determination of oxide thickness using XPS data. The study of surface - plasma interaction was undertaken by correlating results of surface analysis with plasma diagnosis. Different experiments were designed to accurately measure the BEs associated with the Ga 3d, Ga 2p sub 3 sub / sub 2 and LMM peaks using XPS analysis and propose identification in terms of the oxides of GaAs. Along with GaAs wafers, some reference compounds such as metallic Ga and Ga sub 2 O sub 3 powder were used. A separate study aiming the identification of the GaAs surface oxides ...

2002-01-01

9

Polycrystalline MBE-grown GaAs for solar cells  

Energy Technology Data Exchange (ETDEWEB)

This paper will discuss initial studies of thin-film GaAs grown by molecular-beam epitaxy for use in developing a thin-film GaAs solar cell. Photocurrent and photoluminescence intensity are related to the material morphology as a function of growth conditions. Growth temperature and V/III ratio have a dramatic effect on the photocurrent. However, it seems likely that even after optimizing such growth parameters, it will be necessary to provide substrates that can provide templates to enhance grain size from the start of thin-film growth. {copyright} {ital 1997 American Institute of Physics.}

1997-02-01

11

Phase formation sequence in the Pd-GaAs system  

Energy Technology Data Exchange (ETDEWEB)

The morphological aspects of ternary phase formation during the Pd-GaAs reaction have been studied by application of transmission electron microscopy (TEM) and Rutherford backscattering (RBS) techniques. The TEM images show that the first product phase, ''phase I'', forms during deposition of Pd onto (100) GaAs and exhibits the preferred orientation (0001)/sub I/ approx. // (01 anti 1)/sub GaAs/. In the presence of unreacted Pd, the second phase, ''phase II'', nucleates at large-angle grain boundaries in the phase I film as the annealing temperature increases above approx.250C. Energy dispersive analysis of x-rays and RBS suggest the nominal compositions Pd3GaAs and Pd4GaAs for phases I and II, respectively.

1985-12-01

12

Antiferromagnetic ordering of defects in GaAs  

Energy Technology Data Exchange (ETDEWEB)

The magnetic susceptibility of GaAs samples containing a large concentration of native defects was investigated by dc magnetization measurements. Thin GaAs films grown by molecular-beam epitaxy at very low temperatures and bulk GaAs:S samples irradiated with fast neutrons have been studied. For all samples, the susceptibility follows a Curie-Weiss law, indicating the presence of localized magnetic moments. These moments are attributed to unpaired spins located at the native defects. Negative Curie-Weiss temperatures found for both neutron-irradiated and low-temperature-grown GaAs is a clear manifestation of an antiferromagnetic interaction between the moments. The presence of a highly inhomogeneous distribution of native defects has to be assumed to account for the observed antiferromagnetic ordering.

1992-10-15

13

Study of the effects of interactions quantum interference and disorder in GaAs and of GaAs jointed to a superconductor; Etude des effets d`interference quantique et de desordre dans GaAs avec interactions et GaAs connecte a un supraconducteur  

Energy Technology Data Exchange (ETDEWEB)

The aim of this thesis is to study the coherent transport in semiconducting-superconducting junctions. The SnPb-GaAs system has been studied. It has been shown that the behaviour of this junction is controlled by the disordered area induced by the annealing of the connection near the interface. For a few resistant junction, a conductance anomaly under the gap has been observed and has been explained by a mesoscopic effect in the limit of the very high disorders. The conductance of more resistant junctions has only been bound to the properties of the very disordered area of the semiconductor. The part of the electron-electron interactions on the phase coherence length and on the conductance has been studied. The evolving of the correction of the conductance due to interactions in magnetic field has been followed. The effect of the spin degeneration suppression in CdTe and the GaAs sign inversion in ...

1997-11-07

14

Semiconductor Radiation Detectors with Frisch Collars and Collimators for Gamma Ray Spectroscopy and Imaging  

Energy Technology Data Exchange (ETDEWEB)

To study CdZnTe as a high energy resolution gamma ray detector with a novel new design, and to build a detector array from the new detector design

2006-12-04

15

Adhesion studies of Au films on GaAs using ion-assisted deposition techniques  

International Nuclear Information System (INIS)

This paper reports on a series of experiments performed to examine the ability of ion beam assisted thermal deposition to produce good adhesion of Au metallization on GaAs left-angle 100 right-angle substrates. A study of the influence of Ar ion-assisted thermal deposition of the Au films as well as in situ pre-sputtering of the GaAs surface with low-energy Ar ions prior to thermal deposition, shows that strong adhesion can be achieved without resorting to chemical cleaning. The substrate temperature and the relative flux of Ar ions to incident Au atoms were varied in order to correlate these parameters with film adhesion. The interfaces of films processed under these various conditions were examined by XTEM, RBS and XPS. Orientation texture was studied by x-ray diffraction (XRD).

16

High-efficiency GaAs solar cells on mm and sub-mm grain-size polycrystalline Ge substrates  

Energy Technology Data Exchange (ETDEWEB)

GaAs material and device structure optimization studies on optical-grade, millimeter-and-less grain-size polycrystalline Ge substrates are presented. We discuss the growth of high-quality epitaxial layers across various crystalline orientations of a polycrystalline substrate; this is important for obtaining high-performance solar cells. The GaAs solar cell on n-type poly-Ge substrate is a p-on-n type, with an undoped spacer between the p-emitter and the n-base. An experimental study of dark currents in these junctions, with and without the spacer, as a function of temperature (77K to 288K) is presented; this study suggests that the spacer reduces the tunneling contribution to dark current. In addition, we describe device-structure optimization studies that have led us to achieve an open-circuit voltage (V{sub oc}) exceeding 1 Volt and an AM1.5 efficiency of ...

1997-02-01

17

Formation Energies of Antiphase Boundaries in GaAs and GaP: An ab Initio Study  

UK PubMed Central (United Kingdom)

Electronic and structural properties of antiphase boundaries in group III-V semiconductor compounds have been receiving increased attention due to the potential to integration of optically-active III-V...Full Text Available

18

Quasi-elastic electron scattering by GaAs surface  

International Nuclear Information System (INIS)

Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).

1994-03-20

19

Schottky barrier and homojunction gallium arsenide solar cells  

Energy Technology Data Exchange (ETDEWEB)

New techniques were developed to construct Schottky barrier and homojunction solar cells on GaAs substrates. Schottky barrier metal-semiconductor solar cells were produced for the first time on p-type GaAs substrate using a sputter-deposition method to form the barrier. The sputter deposition of gold or gold/palladium is the key to the method since normal thermal evaporation of gold onto p-type GaAs produces ohmic contacts. The results of this investigation are consistent with the idea that sputter damage produces donor type surface states on GaAs. Barrier heights were measured for both p-type sputtered and n-type thermally evaporated diodes using current-voltage and capacitance-voltage methods. Deep-level transient spectroscopy was used to identify the trap center concentration and energy levels for both diodes in an effort to explain the relatively large dark current in the p-type sputtered diodes. ...

1983-01-01

20

Auger electron spectroscopy studies of GaAs and Si metal-semiconductor structures  

Science.gov (United States)

The use of Auger electron spectroscopy (AES) combined with in situ sputter etching for revealing the metallurgy of the metal-semiconductor interface is presented. The physical basis, measurement techniques, and data interpretation for Auger analysis of thin-film structures are briefly reviewed. Results of a detailed study of an alloyed multilayered contact (Ni/Au-Ge) on n-type epitaxial GaAs are summarized to illustrate how electrical and metallurgical contact properties can be correlated using AES. In addition, the results of a study of the growth kinetics and chemical phase identification of palladium silicide on single-crystal Si is given, as well as the initial results of a study of aluminum-palladium silicide interaction at elevated temperature. (auth)

1975-01-01

21

Auger electron spectroscopy studies of GaAs and Si metal-semiconductor structures  

International Nuclear Information System (INIS)

The use of Auger electron spectroscopy (AES) combined with in situ sputter etching for revealing the metallurgy of the metal-semiconductor interface is presented. The physical basis, measurement techniques, and data interpretation for Auger analysis of thin-film structures are briefly reviewed. Results of a detailed study of an alloyed multilayered contact (Ni/Au-Ge) on n-type epitaxial GaAs are summarized to illustrate how electrical and metallurgical contact properties can be correlated using AES. In addition, the results of a study of the growth kinetics and chemical phase identification of palladium silicide on single-crystal Si is given, as well as the initial results of a study of aluminum-palladium silicide interaction at elevated temperature.

22

A final report for: Gallium arsenide P-I-N detectors for high-sensitivity imaging of thermal neutrons  

Energy Technology Data Exchange (ETDEWEB)

This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron ...

1999-04-01

23

Use of signal delay of one of detectors in two-channel radiometric flaw detector  

International Nuclear Information System (INIS)

A possibility is considered or reducing the surface heterogeneity effect of an item being tested on the result of radiation flaw detection by means of signal delay of one of detectors in a two-channel radiometric flaw detector. The exposure of a translationally moving item has been studied as well as an external exposure of a rotating hollow item.

24

Developments and tests of double-sided silicon strip detectors and read-out electronics for the Internal Tracking System of ALICE at LHC  

CERN Document Server

The internal-tracking-system (ITS) of the ALICE detector at LHC, consists of six concentrical barrels of silicon detectors. The outmost two layers are made of double-sided strip detectors (SSD). In the framework of a R and D, the characteristics and performances of these devices, manufactured by two different companies, associated with their designed read-out electronics, have been studied off- and in-beam at the SPS (CERN). The results are presented and discussed.

1999-01-01

25

Ni, Pd, and Pt on GaAs: A comparative study of interfacial structures, compositions, and reacted film morphologies  

Energy Technology Data Exchange (ETDEWEB)

The reactions between (100) GaAs and the near-noble metals Ni, Pd, and Pt have been investigated by application of high-resolution transmission electron microscopy (TEM), energy-dispersive analysis of x rays in the scanning TEM and Rutherford backscattering spectrometry. Emphasis is placed on the evolution of the phase distributions, film compositions, and interface morphologies during annealing at temperatures up to 480 /sup 0/C. The first phase in the Ni/GaAs reaction is shown to have the nominal composition Ni/sub 3/GaAs. Ternary phases of the type Pd/sub x/GaAs are also found to be the dominant products of the Pd/GaAs reaction. Conversely, only binary phases result from the Pt/GaAs reaction. These observations are used to construct isothermal sections of the M--Ga--As thin-film phase diagrams. The behavior of a thin (1--2 nm) native oxide--hydrocarbon layer during the Ni/GaAs, Pd/GaAs, and Pt/GaAs reactions is also investigated. Only the ...

1987-03-01

26

Feasibility investigations of growing and characterizing gallium arsenide crystals in ribbon form. Quarterly progress report 1 Jan-31 Mar 1975  

International Nuclear Information System (INIS)

The feasibility of continuous production of gallium arsenide ribbon single crystals, by passage of a molten zone through boron-oxide encapsulated GaAs feedstock, is being investigated. Polycrystalline GaAs ribbons have been grown in graphite boats by passage of a wide zone through B2O3-encapsulated feed-stock, confined by a quartz cover plate. Failure to remove the encapsulant above its glass transition temperature, however, resulted in cracking of the ribbons on cooling to room temperature. In order to study the crucial zone melting step in isolation from the encapsulation steps of the continuous process, a constrained-zone melting apparatus has been constructed in which the boron oxide serves only as a sealant to suppress arsenic vaporization. Large grained polycrystalline samples have been produced with this apparatus.

27

Development of a small scintillation detector with an optical fiber for fast neutrons  

International Nuclear Information System (INIS)

To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection ...

2011-02-01

28

GCR-induced Photon Luminescence of the Moon: The Moon as a CR Detector  

Science.gov (United States)

We report on the results of a preliminary study of the GCR-induced photon luminescence of the Moon

2007-01-01

29

Growth and electronic properties of two-dimensional systems on (110) oriented GaAs  

Energy Technology Data Exchange (ETDEWEB)

As the only non-polar plane the (110) surface has a unique role in GaAs. Together with Silicon as a dopant it is an important substrate orientation for the growth of n-type or p-type heterostructures. As a consequence, this thesis will concentrate on growth and research on that surface. In the course of this work we were able to realize two-dimensional electron systems with the highest mobilities reported so far on this orientation. Therefore, we review the necessary growth conditions and the accompanying molecular process. The two-dimensional electron systems allowed the study of a new, intriguing transport anisotropy not explained by current theory. Moreover, we were the first growing a two-dimensional hole gas on (110) GaAs with Si as dopant. For this purpose we invented a new growth modulation technique necessary to retrieve high mobility systems. In addition, we discovered and studied the ...

2005-07-01

30

Quantum entanglement, recoherence and information flow in an accelerated detector - quantum field system: Implications for black hole information issue  

CERN Document Server

We study an exactly solvable model where an uniformly accelerated detector is linearly coupled to a massless scalar field initially in the Minkowski vacuum. Using the exact correlation functions we show that as soon as the coupling is switched on one can see information flowing from the detector to the field and propagating with the radiation into null infinity. By expressing the reduced density matrix of the detector in terms of the two-point functions, we calculate the purity function in the detector and study the evolution of quantum entanglement between the detector and the field. Only in the ultraweak coupling regime could some degree of recoherence in the detector appear at late times, but never in full restoration, as an earlier work seems to suggest. We explicitly show that under the most general conditions the ...

2007-01-01

31

Six orders of magnitude dynamic range in capillary electrophoresis with ultrasensitive laser-induced fluorescence detection  

UK PubMed Central (United Kingdom)

An ultrasensitive laser-induced fluorescence detector was used with capillary electrophoresis for the study of 5-carboxy-tetramethylrhodamine. The raw signal from the detector provided roughly...Full Text Available

2009-12-15

32

Advances in imaging THGEM-based detectors  

International Nuclear Information System (INIS)

We report on recent measurements with Thick GEM-like (THGEM)-based imaging detectors. The THGEM is a robust gaseous electron multiplier similar to GEM but with larger dimensions. It has high electron multiplication, of 105 and 107 in single- and double-THGEM structure, respectively, fast signals and ?10MHz/mm2 counting rate capability. It can be produced in any shape and over large area. In view of many possible applications of THGEM-based imaging detectors, in particle physics and beyond, we have recently studied the localization properties of a 2D 10x10cm2 detector. The results of these studies are presented.

2007-03-01

33

Segmented focal plane detector for light and heavy ions  

Energy Technology Data Exchange (ETDEWEB)

A segmented focal plane detector for an Enge split-pole spectrograph has been developed for the study of breakup reactions at very low relative energies. It consists of a 61 cm long segmented position-sensitive parallel plate avalanche counter backed by a large Bragg curve detector. A segmented plastic scintillator is mounted behind the anode of the Bragg curve detector and is used for particle identification of low-ionizing particles. The dead space between the two sections of the focal plane detector is 2.5 mm. The intrinsic position resolution of the detector is 1 mm. The intrinsic energy resolution depends on the energy of the incident ion and can be as good as 0.55%. The nuclear charge and mass resolutions are 0.3 e and 0.3 u, respectively. (orig.).

1992-06-15

34

Space Radiation Detector with Spherical Geometry  

Science.gov (United States)

A particle detector is provided, the particle detector including a spherical Cherenkov detector, and

2011-01-01

35

Fundamental understanding of aging processes Review of the workshop results  

CERN Document Server

A study on the aging process of gas detectors was presented. How the development of more performing but delicate detectors, the use of faster but aggressive gases, and the need to cover large areas, led to unexpected problems was discussed. Various methods for curing aged detectors were also highlighted. (Edited abstract) 37 Refs.

2003-01-01

36

Comparative study of phase stability and film morphology in thin-film M/GaAs systems (M = Co, Rh, Ir, Ni, Pd, and Pt)  

Energy Technology Data Exchange (ETDEWEB)

To attain reproducible and stable contacts to compound semiconductor devices, it is necessary to achieve thermodynamically stable phases after the reaction of metals with the compound semiconductor. In this study, the final phases produced by the reactions between GaAs and thin metal films of Co, Rh, Ir, Ni, Pd, and Pt have been investigated. They are identified as MGa for M = Co, Rh, Ni, Pd, and Pt, monoarsenides of Co and Ni, diarsenides of Rh, Ir, Pd, and Pt, and Ir/sub 3/Ga/sub 5/. These phases, if deposited directly onto GaAs, will produce thermally stable contacts. In addition to the identification of these stable phases, analyses of the products of thin-film M/GaAs reactions by transmission electron microscopy, x-ray diffraction, and Rutherford backscattering spectrometry reveal the distribution, grain size, and crystallographic texture of these end phases. Trends in these observations across the six metal/GaAs ...

1987-09-01

37

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

Energy Technology Data Exchange (ETDEWEB)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.)

1993-10-15

38

A method to study heavy ion reactions using position sensitive and Bragg curve spectroscopy detectors  

International Nuclear Information System (INIS)

A large area Bragg curve spectroscopy (BCS) detector and a position sensitive parallel grid avalanche counter have been developed to study heavy ion reactions, such as inelastic excitations and few nucleon transfer reactions near the Coulomb barrier. Reasonably good resolutions have been achieved for energy, atomic number and angle. A theoretical investigation on the mass dependence of the Bragg peak signal from the BCS detector, shows that there is a negligible mass dependence related to the geometry of the detector. The mass number of the heavy ions which cannot be obtained by the above method, has been identified by detecting the corresponding characteristic gamma rays from the product nuclei with two large solid angle gamma ray detectors. (orig.).

39

Development of a dual-detector X-ray imaging system for phase retrieval study  

International Nuclear Information System (INIS)

Based on a recently introduced phase X-ray imaging approach, a dual-detector prototype was developed for in-line X-ray phase imaging and phase retrieval utilizing a micro-focus X-ray source and two computed radiography (CR) cassette detectors. The system was built on a horizontal optical rail to facilitate manual adjustment of the positions of the X-ray source, the sample and the detectors. The novel design of the detector-1 is essential, it detects a portion of radiation to form an attenuation image; allows the rest of radiation to reach the detector-2 to form a phase contrast image, and the two images are used to retrieve a phase map. The two detectors are balanced for optimal phase-retrieval with reasonable radiation dose to the object to be imaged. The system was examined in terms of the linearity, the fractions of the X-ray photons detected by the two ...

2007-01-01

42

Studies of relativistic heavy ion collisions at the AGS (Experiment 814)  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the experimental setup of experiment 814 at Brookhaven AGS. This experiment involves the collision of silicon ions with target nuclei. The detector systems are discussed primarily. (LSP)

1990-01-01

43

Ultrafast carrier dynamics of InGaAsN and InGaAs single quantum wells  

International Nuclear Information System (INIS)

Striking differences in differential reflectance and carrier relaxation in In0.4Ga0.6As and In0.4Ga0.6As0.98N0.02 single quantum wells (SQWs) were studied using ultrafast time-resolved photoreflectance. Even with extremely thin SQW of only 60 A within 3000 A wide GaAs confining layers, negative and positive differential reflectance was observed for the excitation photon energy far above the bandgaps at 820 and 880 nm for both samples. Due to absorption by the GaAs confining layer, the peak differential reflectance pumped at 820 nm is an order of magnitude larger than that pumped at 880 nm; and it is larger for InGaAs SQWs than for InGaAsN SQWs. The shorter carrier lifetimes of these samples result from carrier-carrier scattering as pumped at both wavelengths. The longer carrier lifetime as pumped at 880 nm is due to hot phonon decay in InGaAs but may be due to stimulated emission in InGaAsN. The results reveal that the ...

2008-04-21

44

Investigation of ultrafast photothermal surface expansion and diffusivity in GaAs via laser-induced dynamic gratings  

Energy Technology Data Exchange (ETDEWEB)

This thesis details the first direct ultrafast measurements of the dynamic thermal expansion of a surface and the temperature dependent surface thermal diffusivity using a two-color reflection transient grating technique. Studies were performed on p-type, n-type, and undoped GaAs(100) samples over a wide range of temperatures. By utilizing a 90 fs ultraviolet probe with visible excitation beams, the effects of interband saturation and carrier dynamics become negligible; thus lattice expansion due to heating and subsequent contraction caused by cooling provided the dominant influence on the probe. At room temperature a rise due to thermal expansion was observed, corresponding to a maximum net displacement of {approximately} 1 {Angstrom} at 32 ps. The diffracted signal was composed of two components, thermal expansion of the surface and heat flow away from the surface, thus allowing a determination of the rate of expansion as well as the surface ...

1992-04-01

45

Experimental Evaluation And Simulation Of Multi-pixel Cadmium-zinc-telluride Hard-x-ray Detectors  

CERN Document Server

This dissertation describes the evaluation of many-pixel Cadmium-Zinc-Telluride (CdZnTe) hard-X-ray detectors for future use with the High Energy Replicated Optics (HERO) telescope being developed at Marshall Space Flight Center. The detector requirements for the HERO application are good energy resolution (sufficient to resolve cyclotron features and nuclear lines), spatial resolution of ∼200 μm, minimal charge loss of absorbed X rays, and minimal sensitivity to the background environment. This research concentrates on assessing the suitability of these detectors for the focus of HERO, and includes the development of a simulation of the physics involved in an X-ray-detector interaction, a study of the intrinsic material properties, measurements with prototype detectors such as the energy and spatial resolution, charge loss, and X-ray background ...

2004-01-01

46

Satellite power study (SPS) concept definition study (exhibit D). Volume 1: executive summary. Final report  

Energy Technology Data Exchange (ETDEWEB)

Efforts concentrated on updating of the Rockwell reference concept, definition of new system options, studies of special emphasis topics, further definition of the transportation system, and further program definition. The Rockwell reference satellite concept has a gallium arsenide (GaAs) solar cell array having flat concentrators with an effective concentration ratio of 1.83at end of life. Alternatives to this concept includes solid state power amplifiers or magnetrons for dc/RF conversion and multibandgap solar cells for solar to dc energy conversion. Two solid state concepts were studied. It was determined that the magnetron approach was the lowest mass and cost system.

1981-03-01

47

Research in experimental elementary particle physics. A proposal to the U.S. Department of Energy  

Energy Technology Data Exchange (ETDEWEB)

We report on the activities of the High Energy Physics Group at the University of Texas at Arlington for the period 1994-95. We propose the continuation of the research program for 1996-98 with strong participation in the detector upgrade and physics analysis work for the D0 Experiment at Fermilab, prototyping and pre-production studies for the muon and calorimeter systems for the ATLAS Experiment at CERN, and detector development and simulation studies for the PP2PP Experiment at Brookhaven.

1995-04-13

48

Medical explorations by radioisotopes in Lebanon  

International Nuclear Information System (INIS)

This study mainly concerns medical explorations by radioisotopes. Detectors with medical exams and applications are described. Ionisation chambers, semiconductor detectors and scintillation counters are also presented. Uses of radioisotopes in medicine in vivo and in vitro techniques are explained. Examples of scintiscanning are given like: angiography, nuclear cardiography and thyroid scintiscanning. The importance of the study is to present a panorama of nuclear medicine laboratories -at the time- in hospitals in Lebanon.

49

Tests with superconducting re-entrant cavities for transducer applications in gravitational wave detectors  

International Nuclear Information System (INIS)

We studied the niobium re-entrant cavity utilized by the Australian group in the Niobe gravitational wave detector. Instead of using their non-contact re-entrant cavity, we plan to change it to a closed one to be used in the parametric transducers of the Brazilian Mario Schenberg detector. The performance of the transducer depends on some cavity parameters such as the electrical Q and the electrical coupling. We measured the resonant frequency and the loaded electrical Q as a function of the probe position in a closed niobium #approx#15 GHz cavity operating at 4.2 K.

2004-03-07

50

Studies of a Poenitz-type black neutron detector as a neutron flux monitor  

Energy Technology Data Exchange (ETDEWEB)

A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).

1997-04-01

51

Silicon Detector Letter of Intent  

Energy Technology Data Exchange (ETDEWEB)

This document presents the current status of SiD's effort to develop an optimized design for an experiment at the International Linear Collider. It presents detailed discussions of each of SiD's various subsystems, an overview of the full GEANT4 description of SiD, the status of newly developed tracking and calorimeter reconstruction algorithms, studies of subsystem performance based on these tools, results of physics benchmarking analyses, an estimate of the cost of the detector, and an assessment of the detector R&D needed to provide the technical basis for an optimised SiD.

2010-05-26

52

Electronics for the Si detectors in APEX  

Energy Technology Data Exchange (ETDEWEB)

APEX (ATLAS Positron EXperiment), a collaborative effort of ANL, FSU, MSU/NSCL, Princeton, Queen`s, Rochester, Washington and Yale, is an experiment to study positron and electron production in very heavy ion collisions. The electrons and positrons are detected with two detector arrays, each consisting of 216 1 mm thick Si PIN diodes, and their energy and time-of-flight are measured. The number of detectors and limited space made it necessary to develop a system that could efficiently process and transfer signals from the detectors to the charge sensing ADC`s and data readout electronics as well as monitor the condition of the detectors. The discussion will cover the electronics designed for the Si detectors, including the charge amplifier, ``Mother board`` for the charge amplifiers, 8 channel Shaper, 16 channel Constant Fraction Discriminator (CFD), 16 channel ...

1994-07-01

53

Development of Micromegas-like gaseous detectors using a pixel readout chip as collecting anode  

International Nuclear Information System (INIS)

This thesis reports on the fabrication and test of a new gaseous detector with a very large number of readout channels. This detector is intended for measuring the tracks of charged particles with an unprecedented sensitivity to single electrons of almost 100 %. It combines a metal grid for signal amplification called the Micromegas with a pixel readout chip as signal collecting anode and is dubbed GridPix. GridPix is a potential candidate for a sub-detector at a future electron linear collider (ILC) foreseen to work in parallel with the LHC around 2020--2030. The tracking capability of GridPix is best exploited if the Micromegas is integrated on the pixel chip. This integrated grid is called InGrid and is precisely fabricated by wafer post-processing. The various steps of the fabrication process and the measurements of its gain, energy resolution and ion back-flow property are reported in this document. ...

54

Characterization of 3D thermal neutron semiconductor detectors  

International Nuclear Information System (INIS)

Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different column sizes were fabricated to study the ...

2007-06-11

55

The mass dependence of the signal peak height of a Bragg-curve ionization chamber  

International Nuclear Information System (INIS)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required. (orig.).

56

The Brazilian Bragg curve detector built for AMS studies  

Energy Technology Data Exchange (ETDEWEB)

A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.

2000-10-01

57

Studies of crystalline CdZnTe radiation detectors and polycrystalline thin film CdTe for X-ray imaging applications  

CERN Document Server

The development of a replacement to the conventional film based X-ray imaging technique is required for many reasons. One possible route for this is the use of a large area film of a suitable semiconductor overlaid on an amorphous silicon readout array. A suitable semiconductor exists in cadmium telluride and its tertiary alloy cadmium zinc telluride. In this thesis the spectroscopic characteristics of commercially available CZT X- and gamma-radiation detectors are established. The electronic, optical, electro-optic, structural and compositional properties of these detectors are then investigated. The attained data is used to infer a greater understanding for the carrier transport in a CZT radiation detector following the interaction of a high energy photon. Following this a method used to fabricate large area films of CdTe on a commercial scale is described. This is cathodic electrodeposition from an aqueous electrolyte. ...

2001-01-01

58

Screening Samples with a Position-Sensitive Detection System Providing Isotope-Specific Information  

International Nuclear Information System (INIS)

The properties of individual radioactive particles present in a sample, such as a swipe, are more interesting than bulk properties of the sample. The present work focuses on instrumentation that provides position-sensitive spectral information non-destructively from the sample. The experimental part of the work was realized using a device called PANDA (Particles And Non-Destructive Analysis). The detector setup used in the study contains a broad-energy HPGe gamma-ray detector and a position-sensitive alpha detector. Both detectors are connected to a time-stamping event-mode data acquisition system. The method is shown to locate particles with sub-millimetre accuracy and distinguish the interesting particles from non-interesting ones. (author)

2010-11-01

59

PERFORMANCE-LIMITING DEFECTS IN CDZNTE DETECTORS.  

Energy Technology Data Exchange (ETDEWEB)

We studied the effects of small, <20 {micro}m, Te inclusions on the energy resolution of CdZnTe gamma-ray detectors using a highly collimated X-ray beam and gamma-rays, and modeled them via a simplified geometrical approach. Previous reports demonstrated that Te inclusions of about a few microns in diameter degraded the charge-transport properties and uniformity of CdZnTe detectors. The goal of this work was to understand the extent to which randomly distributed Te-rich inclusions affect the energy resolution of CZT detectors, and to define new steps to overcome their deleterious effects. We used a phenomenological model, which depends on several adjustable parameters, to reproduce the experimentally measured effects of inclusions on energy resolution. We also were able to hound the materials-related problem and predict the enhancement in performance expected by reducing the size and number of Te ...

2006-10-29

60

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

International Nuclear Information System (INIS)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1 MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

61

Overview of the recent activities of the RD50 collaboration on radiation hardening of semiconductor detectors for the sLHC  

British Library Electronic Table of Contents (United Kingdom)

The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeV neutron equivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.

2009-01-01

62

Mass dependence of the signal peak height of a Bragg-curve ionization chamber  

Energy Technology Data Exchange (ETDEWEB)

The Bragg-curve detector of the parallel plate ionization chamber type generates a signal that is a distorted replica of the original Bragg-curve. In result of this distortion, the signal peak height is not only a function of the atomic number of the heavy ion, as it is often stated, but also of the particle mass. This mass effect was studied with the aid of computer simulation, and it was found to be dependent on the Frisch grid to anode gap width and on the detector gas. The charge resolution of the detector is affected very significantly by this mass dependence of the signal peak height. Therefore, a careful selection of the detector gas and the grid to anode gap width is necessary, if good charge resolution over a wide range of heavy ions is required.

1985-01-01

63

Determination of Proper Peaking Time for Ultra Lege detector at Medium Energies  

International Nuclear Information System (INIS)

Reducing count losses and pile-up pulse effects in quantitative and qualitative analysis is necessary for accuracy of analysis. Therefore, the optimum peaking time for particular detector systems is important. For this purpose, pure Se and Zn elements were excited by 59.5 keV ?-rays from a 50 mCi 241Am annular radioactive source in this study. The characteristic x-rays emitted from pure Se and Zn elements were detected by using an ultra low energy Ge (Ultra-LEGe) detector connecting Tennelec TC 244 spectroscopy amplifier at different peaking time modes. Overall pulse widths were determined by HM 203-7 oscilloscope connecting amplifier. The proper peaking time for ultra low energy germanium detector (Ultra-LEGe) is determined about 4 ?s.

2008-08-25

64

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

Energy Technology Data Exchange (ETDEWEB)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

1993-12-31

65

Comparison of effectiveness of three radon detectors (LR115, CR39 and silicon diode pin) placed in a cylindrical device -theory and experimental techniques  

International Nuclear Information System (INIS)

Researchers at the Laboratory of Nuclear Microanalysis in Besancon (France) are developing and improving radon measurements in order to detect and analyse, more precisely radon emanation anomalies in both fields of Earth Sciences and Radioprotection. In order to characterize radon emanation, two complementary techniques are developed; continuous measurement through a portable proportional counter and passive measurements by nuclear track detectors for both fieldwork and laboratory analysis. A mathematical model is being devised to interpret the nuclear track detector response. This model is performed according to the device characteristics: type of detectors, shape and size of cells and whether a membrane is used or not. In addition to the theoritical study, experimental radon concentration measurements will be reported. (author).

66

Annihilation of antiprotons in light nuclei  

CERN Document Server

CR-39 detectors have been exposed to a 5.9-MeV antiproton beam using the low energy antiproton ring (LEAR) facility at CERN. At this energy, tracks of antiprotons appear in a CR-39 detector after 135 min of etching in 6 M NaOH at 70C. Fluence of the antiproton beam has been determined using track density. We have also found tracks in the etched CR-39 detector at different depths (250-500 mum). These tracks have resulted from the annihilation of antiprotons with the constituents (H, C and O) of the CR-39 detector. The goal of the experiment is to develop a simple and low-cost method to study properties of antiparticles and those formed after annihilation of these particles with the target matter.

2006-01-01

67

Efficiency of silicon and GaAs concentrator solar cells operated inside integrating cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

The theory for the general case of solar cells operating inside integrating cavity receivers is established. This is applied to the particular case of different configurations of silicon and GaAs cells. The results of the analysis show that a composite system of silicon and GaAs cells manufactured using relatively simple technology could reach an efficiency of 34%. The optimal configuration is that in which the GaAs cells are placed in the directly illuminated area of the receiver and the silicon cells are placed in the indirectly illuminated area of the receiver. (orig.).

1991-06-01

69

Intercomparison of Retrospective Radon Detectors  

Energy Technology Data Exchange (ETDEWEB)

We performed both a laboratory and field intercomparison of two novel glass-based retrospective radon detectors previously used in major radon case-control studies performed in Missouri and Iowa. The new detectors estimate retrospective residential radon exposure from the accumulation of a long-lived radon decay product, Pb-210, in glass. The detectors use track registration material in direct contact with glass surfaces to measure the alpha emission of a Pb-210 decay product, Po-210. The detector's track density generation rate (tracks cm{sup -2} hr{sup -1}) is proportional to the surface alpha activity. In the absence of other strong sources of alpha emission in the glass, the implanted surface alpha activity should be proportional to the accumulated Po-210 and hence, the cumulative radon gas exposure. The goals of the intercomparison were to: (1) perform collocated ...

1998-11-01

70

Enhancement of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 (16N) and Oxygen-19 (19O) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of 19O and 16N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high ambient radiation level even though sensitivity is appreciably good. For detector position in ...

2006-11-13

71

Diffuse X-ray scattering study of sublattice ordering among group III atoms in In_0_._5Ga_0_._5P and In_0_._5Al_0_._5P  

International Nuclear Information System (INIS)

The intensity of superstructure reflections and associated diffuse scattering from In_0_._5Ga_0_._5P and In_0_._5Al_0_._5P epitaxic layers grown on (001) GaAs substrates was mapped in reciprocal space. The Warren-Cowley short-range-order parameters were obtained through the usual process for evaluating Fourier coefficients. Varying values for the correlation length in different directions indicate how group III atoms stack up in ordered states. The resultant structure with long-range order confirms the hypothesis made on the basis of electron diffraction and high-resolution transmission electron microscopy studies. (orig.).

72

Study on reactivity measurement by the Feynman-#alpha# method  

International Nuclear Information System (INIS)

The Feynman-#alpha# method was applied to measurement of reactivity and the ability of this method for a real-time reactivity monitoring system was assessed. In the experiment, all measured data by BF_3 detectors were stored in a multi-channel scaler controlled by a personal computer, and they were analyzed to obtain prompt neutron decay constant (#alpha#) and reactivity with consideration of dead time of detector. It was found that #alpha# could be obtained almost in a real-time even for both positive and negative reactivities by the present experimental technique. (author).

1996-09-01

73

CPA simulator: A software tool to simulate nuclear front-end circuit response  

International Nuclear Information System (INIS)

A computer program 'CPA simulator' has been designed to simulate the response parameters of a typical charge preamplifier (CPA) used in nuclear front-end electronics. The response parameters are studied considering three common connection methods between the detector and the CPA. The simulator predicts and illustrates the role and influence of the different components of the CPA and detector circuits.

2010-12-21

74

A large-acceptance Bragg curve spectrometer with a longitudinal electric field and a segmented anode  

Energy Technology Data Exchange (ETDEWEB)

A large-acceptance Bragg curve spectrometer with a longitudinal electron collection field and a segmented anode has been constructed and tested. The effects on the charge resolution of the entrance angle and entrance position of the incident particle have been studied. Simulations have been done in order to isolate the contribution to the overall detector performance of the signal-shaping electronics from that of the intrinsic design of the detector. ((orig.))

1994-07-15

75

Temperature dependence of threshold current of injection lasers for short pulse excitation  

Energy Technology Data Exchange (ETDEWEB)

We report measurements of the temperature dependence of the threshold current of GaAs, 1.3-..mu..m InGaAsP, and 1.5-..mu..m InGaAsP double heterostructure lasers using short electrical pulses. T/sub 0/approx.200 K is observed for all the lasers. These high T/sub 0/ values show that the carrier density at threshold does not increase rapidly with increasing temperature in any of the lasers studied and thus the observed low cw T/sub 0/ of InGaAsP lasers is primarily due to a decrease of the carrier lifetime at threshold with increasing temperature.

1984-05-15

76

Point defects in dilute nitride III-N-As and III-N-P  

International Nuclear Information System (INIS)

We provide a brief review of our recent results from optically detected magnetic resonance studies of grown-in non-radiative defects in two most important dilute nitride systems-Ga(In)NAs grown on GaAs substrates and Ga(Al,In)NP grown on Si and GaP substrates. These results have led to the identification of defect complexes in the alloys, involving intrinsic defects such as As_G_a antisites and Ga_i self-interstitials. They have also shed light on formation mechanisms of the defects and on their role in non-radiative carrier recombination that is harmful to the performance of potential optoelectronic and photonic devices based on these dilute nitrides.

2006-04-01

77

New III-V cell design approaches for very high efficiency. Annual subcontract report, 1 August 1990--31 July 1991  

Energy Technology Data Exchange (ETDEWEB)

This report describes progress during the first year of a three-year project. The objective of the research is to examine new design approaches for achieving very high conversion efficiencies. The program is divided into two areas. The first centers on exploring new thin-film approaches specifically designed for III-V semiconductors. The second area centers on exploring design approaches for achieving high conversion efficiencies without requiring extremely high quality material. Research activities consisted of an experimental study of minority carrier recombination in n-type, metal-organic chemical vapor deposition (MOCVD)-deposited GaAs, an assessment of the minority carrier lifetimes in n-GaAs grown by molecular beam epitaxy, and developing a high-efficiency cell fabrication process.

1993-01-01

78

New III-V cell design approaches for very high efficiency  

Energy Technology Data Exchange (ETDEWEB)

This report describes progress during the first year of a three-year project. The objective of the research is to examine new design approaches for achieving very high conversion efficiencies. The program is divided into two areas. The first centers on exploring new thin-film approaches specifically designed for III-V semiconductors. The second area centers on exploring design approaches for achieving high conversion efficiencies without requiring extremely high quality material. Research activities consisted of an experimental study of minority carrier recombination in n-type, metal-organic chemical vapor deposition (MOCVD)-deposited GaAs, an assessment of the minority carrier lifetimes in n-GaAs grown by molecular beam epitaxy, and developing a high-efficiency cell fabrication process.

1993-01-01

79

Analysis of efficacy of process water monitors in detecting heavy water leak in steam generator blow down lines  

International Nuclear Information System (INIS)

The Steam Generator (SG) serves as an interface between primary and secondary cycle in Pressurized Heavy Water Reactor (PHWR). Failure of steam generator tubes result in leaking of active heavy water in the secondary closed loop. In Tarapur Atomic Power Station-3 and 4 (TAPS- 3 and 4), Scintillator detectors are provided to detect on line heavy water leakages in SG and moderator heat exchangers by monitoring Nitrogen-16 ("1"6N) and Oxygen-19 ("1"90) activities. Efficacy of detection of these activities at designed detector position on SG blow down line in presence of background radiation field is analysed theoretically. The count rate of "1"9O and "1"6N estimated at the detector position inside Reactor Building (RB) shows that detectors only respond to very high leak rates due to presence of high background even though sensitivity is appreciably good. For detector position out side ...

2005-11-23

80

Development of high-efficiency GaAs solar cells on polycrystalline Ge substrates  

Energy Technology Data Exchange (ETDEWEB)

Progress in the development of high-efficiency GaAs solar cells on low-cost, large-area, large-grain, optical-grade polycrystalline Ge substrates is described in this paper. First, we present results on the growth of specular GaAs-AlGaAs layers, across the various crystalline orientations of a polycrystalline Ge substrate, by metallorganic chemical vapor deposition (MOCVD). Second, we present the preliminary optimization of minority-carrier properties of GaAs-AlGaAs structures on poly-Ge substrates towards the improvement of GaAs solar cells. We have demonstrated comparable minority-carrier lifetimes in GaAs double-hetero structures grown on optical-grade poly-Ge substrates and electronic-grade single-crystal Ge substrates. In addition, we describe device-structure optimization that have led us to achieve a open-circuit voltage of {approximately}1 Volt in a GaAs solar cell on poly-Ge and to improve our ...

1996-01-01

81

Comparison of LaBr_3:Ce and NaI(Tl) Scintillators for Radio-Isotope Identification Devices  

International Nuclear Information System (INIS)

Lanthanum halide (LaBr_3:Ce) scintillators offer significantly better resolution (< 3% at 662 keV) relative to NaI(Tl) and have recently become commercially available in sizes large enough for the handheld, Radio-Isotope Identification Device (RIID) market. Drawbacks to lanthanum halide detectors, however, include internal radioactivity contributing to spectral counts, and a low-energy response which can cause detector resolution to be worse than that of NaI(Tl) below 100 keV. To study the potential of this new material for RIIDs we performed a series of measurements comparing a 1.5 x 1.5-inch LaBr_3:Ce detector with an Exploranium GR-135 RIID, which contains a 1.5 x 2.2-inch NaI(Tl) detector. Measurements were taken for short timeframes, as typifies RIID usage. Measurements included examples of naturally occurring radioactive material (NORM), typically found in cargo, and ...

2005-10-23

82

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

Energy Technology Data Exchange (ETDEWEB)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a {sup 241}Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

1991-01-01

83

Indoor radon concentration measurements in some Spanish houses and dwellings with plastic nuclear track detectors  

International Nuclear Information System (INIS)

A passive dosemeter, based on a Makrofol ED track detector covered with aluminized Mylar, enclosed in diffusion chamber, has been used for radon concentration studies. Detectors have been irradiated, using a "2"4"1Am source, at different energies and fluences in order to obtain the electrochemical etching conditions that allow the optimum registration of alpha particles having energies over 3 MeV. Thirty dosemeters have been sent to the UK National Radiation Protection Board (NRPB) Radon Environmental Chamber for calibration. The sensitivity of the dosemeter has been calculated. Several dosemeters have also been exposed in houses and dwellings in the Barcelona and Madrid areas for monitoring. Values for radon concentration in the areas under study are presented. (author).

84

The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy  

UK PubMed Central (United Kingdom)

BackgroundMany studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for...Full Text Available

85

Study of Stent Deployment Mechanics Using a High-Resolution X-ray Imaging Detector  

UK PubMed Central (United Kingdom)

To treat or prevent some of the 795,000 annual strokes in the U.S., self-expanding endo-vascular stents deployed under fluoroscopic image guidance are often used. Neuro-interventionalists need...Full Text Available

2011-03-01

86

Performance assessment for EEG-based neonatal seizure detectors  

UK PubMed Central (United Kingdom)

ObjectiveThis study discusses an appropriate framework to measure system performance for the task of neonatal seizure detection using EEG. The framework is used to present an extended...Full Text Available

2011-03-01

87

Assessment of detector sensitivity and uniformity during SPECT rotation  

International Nuclear Information System (INIS)

The purpose of this research was to: a) evaluate variations in sensitivity and uniformity of SPECT detectors during 360"0 rotation, b) explore the causes of the variations and c) to discuss a correction procedure. A flood source consisting of a lucite disc 47.7 cm in diameter containing 3 microcuries of Co-57 was constructed. This source can be firmly attached to the uncollimated detector guaranteeing no detector-source geometry change during rotation. Four different SPECT cameras were tested. Measurements were obtained at 45"0 intervals throughout a 360"0 rotation, and repeated in 3 different orientations with respect to the earth's magnetic field. In one camera the effects of the direction and strength of induced magnetic fields were studied. All detectors showed cyclic rotational variations in sensitivity; in three cameras 6%, in one 3%. The amplitude and phase of the sensitivity ...

1984-06-05

88

Real time neutron dosemeter response calculations  

International Nuclear Information System (INIS)

The response of a real time neutron dosemeter using a thin LiF target sandwiched between tow parallel surface barrier semiconductor detectors is studied for different neutron distributions and different angles of incidence. Calculations of the response function defined for a simultaneous detection by the two detectors of the particles emitted when the reaction "6Li(n,t)#alpha# occurs in the target are fulfilled by geometrical considerations of the reaction kinematics and the differential cross section variations. Finally, the efficiency of the studied detection systems is analyzed for dosimetric uses. (author).

1996-04-01

92

Measurements and elimination of Cherenkov light in fiber-optic scintillating detector for electron beam therapy dosimetry  

International Nuclear Information System (INIS)

In this study, a miniature fiber-optic radiation detector has been developed using a water-equivalent organic scintillator for electron beam therapy dosimetry. Usually, two kinds of light signals such as fluorescent and Cherenkov lights are generated in a fiber-optic radiation detector when a high-energy electron beam is irradiated. The fluorescent light signal is produced in the scintillator and is transmitted through a plastic optical fiber to a remote light-measuring device such as a PMT or a photodiode. The Cherenkov light could be also produced in the plastic optical fiber itself and be detected by a light-measuring device. Therefore, it could cause problems or limit the accuracy of the detection of a fluorescent light signal that is proportional to dose. The objectives of this study are to measure, characterize and eliminate Cherenkov light generated in a plastic optical fiber used as a component ...

2007-08-21

93

Status of combined point source search with neutrino telescopes IceCube and AMANDA  

Energy Technology Data Exchange (ETDEWEB)

In this talk, we summarize recent results obtained from the combined neutrino telescopes IceCube and AMANDA. The combined approach, including data taken from both detectors simultaneously, is compared to other analyses that are using IceCube only data. The main benefit of the combined detector is its improved performance at low energies, meaning energies below 1 TeV (close to the energy threshold of the detector). The discussion is focused on the search for extra-terrestrial neutrinos from candidate sources in our Galaxy. Using appropriate cuts, the sensitivity can be optimized for soft spectra neutrino sources. With the resulting data sample, several studies are performed: an unbinned Galactic Plane Scan and a Cygnus region analysis: the Multi Point Source analysis. The current status of these analyses is presented.

2010-07-01

94

Particle and X-ray damage in pn-CCDs  

Energy Technology Data Exchange (ETDEWEB)

The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.

2000-01-11

95

Feasibility study of the iterative x-ray phase retrieval algorithm  

International Nuclear Information System (INIS)

An iterative phase retrieval algorithm was previously investigated for in-line x-ray phase imaging. Through detailed theoretical analysis and computer simulations, we now discuss the limitations, robustness, and efficiency of the algorithm. The iterative algorithm was proved robust against imaging noise but sensitive to the variations of several system parameters. It is also efficient in terms of calculation time. It was shown that the algorithm can be applied to phase retrieval based on one phase-contrast image and one attenuation image, or two phase-contrast images; in both cases, the two images can be obtained either by one detector in two exposures, or by two detectors in only one exposure as in the dual-detector scheme.

2009-01-01

96

Wet chemical etch solutions for Al{sub x}Ga{sub 1{minus}x}P  

Science.gov (United States)

Heterostructures based on AlGaInP alloy compounds are very attractive for visible semiconductor lasers, heterojunction bipolar transistors (HBTs), and high-electron-mobility transistors (HEMTs) lattice matched to GaAs substrates. Several wet etching solutions for AlGaP of different compositions have been studied. Al{sub 0.5}Ga{sub 0.5}P is found to etch in HF, H{sub 3}PO{sub 4}, hyphosphorous acid (HOPH{sub 2}:O), HCl, KOH, and 1% Br{sub 2}-methanol (MeOH). Etching of Al{sub 0.5}Ga{sub 0.5}P in HCl is reaction limited with an activation energy of {approximately}54.4 kJ/mol. At fixed conditions, the etch rates of Al{sub x}Ga{sub 1{minus}x}P vary exponentially with x in HF and HCl, while in 1% Br{sub 2}-MeOH and mixtures of HCl and HNO{sub 3} the etch rates follow a linear dependence on AlP mole fraction. HF has been found to be a good etchant for AlGaP over InGaP or AlInP with high selectivity, while HCl is useful for the reverse case. The use ...

1996-01-01

97

Solid-state precursor routes to III-V type electronic (13-15) and magnetic (3-15) materials  

Science.gov (United States)

An interest in electronic materials has led me to investigate new synthetic approaches to III-V' type semiconducting (13-15, current IUPAC designation for B and N groups in the Periodic Table) and magnetic (3-15) compounds. It is now possible to prepare binary (GaAs and GdP) and ternary mixed-metal (Al[sub x]Ga[sub 1-x]As) and mixed-pnictide (GaP[sub x]As[sub 1-x]) compounds in seconds from rapid, low-temperature-initiated metathesis reactions between a metal (III) trihalide and a trisodium pnictide, exemplified by MX[sub 3] + Na[sub 3]Pn [yields] MPn + 3 NaX, where M is Al, Ga, In, (Al,Ga), or a lanthanide; X is F, Cl, or I; and Pn is P, As, Sb, or (P,As). The precursors are mixed together in a dry box and ignited by light grinding with a mortar and pestle, or by brief, local heating from a hot filament. These reactions are very exothermic (calculated [Delta]H[sub rxn] (GaAs) = 138 kcal/mol) and typically reach temperatures in excess ...

1992-01-01

98

The Structural and Optical Properties of GaAs1-xPx /GaAs  

International Nuclear Information System (INIS)

GaAs1-xPx p-n junction structures were grown on the epi-ready n-type GaAs(100) substrate by solid source MBE system for different phosphor compositions. To obtain the lattice-match sample structure was applied graded growth procedure. The structural and optical properties of the sample structures with different P concentration were investigated by using X-ray diffraction (XRD), spectroscopic ellipsometry (SE). In addition, The range of lattice parameters in the graded epilayer and phosphorous composition were determined from the HRXRD rocking curve simulation. We analyse dielectric function spectra of disordered GaAs1-xPx junction structures measured using spectroscopic ellipsometry at room temperature in the 0.6-4.7 eV photon energy region. The critical energy points such as band gap energy and spin-orbit-split energy of these structures were determined using SE data. It is detected that E0, E1 ,E2 energies of the ...

2008-08-25

99

The Pamela Cosmic Ray Space Observatory: Detector, Objectives and First Results  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to ...

2009-01-01

100

Position sensitive and Bragg curve spectroscopy detector system for heavy ion reaction studies  

International Nuclear Information System (INIS)

A complete heavy ion identification system in heavy ion reaction studies consists, in general, of: 1) a position sensitive avalanche counter, and 2) ionization chamber to obtain total energy as well as a heavy ion identifier signal (such as the E#DELTA#E signal from a E-#DELTA#E type detector or the height of the Bragg peak that scales as Z of the heavy ion in a Bragg curve ionization chamber). In addition, a time-of-flight information may be needed to resolve the masses of the ions. With this motivation in mind, a composite detector system consisting of a Bragg curve spectroscopy ionization chamber (BCS-IC) and a one dimensional position sensitive parallel grid avalanche counter (XPS-PGAC) has been developed and used successfully at the BARC-TIFR pelletron accelerator facility. The design and performance of this gas detector system are reported. (author). 4 refs., 2 figs.

101

Optical Modelling of the HFI Instrument on Board the Planck Surveyor  

Science.gov (United States)

The PLANCK SURVEYOR is a European Space Agency satellite mission to image the very faint anisotropies in the temperature of the Cosmic Microwave Background (CMB) radiation. Maynooth is actively participating in an international collaboration of scientists involved with the optical design of the High Frequency Instrument (HFI). This paper outlines research which has been undertaken in Maynooth concerned with numerical modelling of the optical characteristics of the multi-frequency array of detectors making up the HFI instrument. In the study the commercial software package ZEMAX was used to model the coupling of the focal plane HFI detectors to the PLANCK telescope. This package is particularly useful in the optical design of PLANCK because of the powerful optimisation features of the software. It is thus possible to readily determine the optimum positioning of the detectors in the focal plane of the ...

1999-07-01

102

Instrumentation and Controls Division progress report, September 1, 1980-July 1, 1982  

Energy Technology Data Exchange (ETDEWEB)

Activities are reported by the Reactor Systems Section, Research Instrument Section, and the Measurement and Controls Engineering Section. Reactor system activities include dynamic analysis, survillanc and diagnostic methods, design and evaluation, detectors, facilities support, process instrumentation development, and special assignments. Activities in the Research Instrument Section include the Navy-ORNL RADIAC development program, advanced ..gamma.. and x ray detector systems, neutron detection and subcriticality measurements, circuit development, position-sensitive detectors, stand-alone computers, environmental monitoring-detectors and systems, plant security, engineering support for fusion energy division, engineering support for accelerator physics, and communications: radio, closed-circuit tv, and computer. Activities in the Measurement and Controls Engineering Section include the AVLIS program; ...

1982-12-01

103

High energy physics  

International Nuclear Information System (INIS)

The research of the CELLO collaboration is reviewed. After a description of the CELLO detector tests of QCD and hadronic final states by determination of the strong coupling constant and studies of inclusive production of electrons and muons in multihadronic events in e"+e"- annihilation are described. Then studies of deep inelastic e#gamma# scattering with lepton pair production and the study of the structure function of the photon are briefly described. Finally studies on QED processes are described together with tau decays. (HSI).

1983-11-01

104

GaInP[sub 2]/GaAs tandem cells: Problems and solutions  

Energy Technology Data Exchange (ETDEWEB)

The various factors that affect the open-circuit voltage ([ital V][sub oc]) of a two-terminal GaInP[sub 2]/GaAs tandem cell are examined. These include a) an anomalous problem associated with the GaAs bottom cell and b) back surface passivation of the thin GaInP[sub 2] top cell. Solutions to these problems are presented and yield tandem [ital V][sub oc]s close to the practical theoretical limits.

1992-12-01

105

Formation and coarsening of Ga droplets on focused-ion-beam irradiated GaAs surfaces  

International Nuclear Information System (INIS)

We have investigated the formation and coarsening of Ga droplets on focused-ion-beam (FIB) irradiated GaAs surfaces. To separately examine formation and coarsening, Ga droplets were fabricated by Ga"+ FIB irradiation of GaAs substrates with and without pre-patterned holes. We determined the droplet growth rate and size distribution as a function of FIB energy following irradiation. The data suggest a droplet formation mechanism that involves Ga precipitation from a Ga-rich layer, followed by droplet coarsening via a combination of diffusion and Ostwald ripening or coalescence via droplet migration (dynamic coalescence).

2009-10-12

106

Symbol Error Rates of Maximum-Likelihood Detector: Convex/Concave Behavior and Applications  

CERN Document Server

Convexity/concavity properties of symbol error rates (SER) of the maximum likelihood detector operating in the AWGN channel (non-fading and fading) are studied. Generic conditions are identified under which the SER is a convex/concave function of the SNR. Universal bounds for the SER 1st and 2nd derivatives are obtained, which hold for arbitrary constellations and are tight for some of them. Applications of the results are discussed, which include optimum power allocation in spatial multiplexing systems, optimum power/time sharing to decrease or increase (jamming problem) error rate, and implication for fading channels.

2007-01-01

107

Response of track-etch dosemeters to environmental radon  

Energy Technology Data Exchange (ETDEWEB)

The reliability of outdoor radon concentration measurements using the track-etch technique is affected by the environmental conditions. Studies have been made to improve stability of nuclear tracks in detector material and to achieve a stable dosemeter response. A dosemeter was developed utilizing chemically etched MA-ND/alpha (CR-39) detector which is thermally insulated and protected against solar irradiation. The calibration showed that its response amounts to 0.21 {plus minus} 0.03 tracks m{sup -2}/Bqm{sup -3} day and was found to be in good agreement with theoretical prediction. (author).

1988-01-01

108

Positron-Electron Pair Creation Near Threshold  

Science.gov (United States)

Positron-electron pair creation near the threshold energy is extremely difficult to investigate by both experiments and theory. First test experiments were performed at the ILL to determine the cross sections for positron-electron pair creation near threshold using prompt {gamma}-rays from different targets after neutron capture and conventional radioactive sources. Pair creation was studied in a Ge detector, which simultaneously acted as sample and detector. First results are presented which show a significant deviation from theoretical values near threshold.

2009-01-28

109

Passive dosimetry of radon and its daughters using solid state nuclear track detectors (SSNTDs)  

Energy Technology Data Exchange (ETDEWEB)

Indoor radon is a potential health hazard for the general public, especially in buildings with poor ventilation. A variety of dosemeters have been developed and used in surveys of radon concentration measurements. In this article the passive dosemeters which are based on solid state nuclear track detectors are reviewed. The principle of passive dosimetry and the factors affecting their performance are discussed. The characteristics of SSNTD materials in relation to their behaviour under different environmental conditions are tabulated and discussed. Results of radon surveys from selected studies are also presented. (Author).

1993-01-01

110

Measurement of the inclusive Z production cross section with the CMS detector  

CERN Document Server

First measurements of inclusive Z production cross sections in muon and electron decay channels at 7 TeV are presented for proton-proton collisions in the Compact Muon Solenoid (CMS) detector at the Large Hadron Collider (LHC). The comparison of the kinematic quantities as well as the studies of selection efficiencies demonstrate a good agreement between simulated events and current data. The measured inclusive cross section for Z($\\gamma^{*}$) production agrees with NNLO QCD cross section calculations and current parton distribution functions.

2010-01-01

111

Acoustic response of piezoelectric lead-zirconate-titanate to a 400MeV/n xenon beam  

Energy Technology Data Exchange (ETDEWEB)

Characteristics of lead-zirconate-titanate (PZT) elements were studied by directly irradiating them with a 400 MeV/n Xe beam. The elements were sensitive to 10{sup 4} Xe ions and their output amplitudes were proportional to the beam intensity. An ensemble of those output amplitudes displayed a Bragg-curve-like response towards the range of 400 MeV/n Xe ion. We discuss the potential of PZT elements as a radiation detector and their application to high-intensity and high-energy detectors. (author)

2003-03-01

112

A study of aging effects in gas proportional detectors at the BAC calorimeter of the ZEUS experiment  

Energy Technology Data Exchange (ETDEWEB)

The multicell proportional chambers at the backing calorimeter of the ZEUS experiment at the storage ring HERA are supplied with a gas mixture of Ar/CO[sub 2] by an open gas system. Flow proportional counters with the build-up [sup 55]Fe sources are used as gas system monitoring detectors. The ZEUS experiment is planned to collect data for about 10 years. Therefore, the lifetime of the Ar/CO[sub 2] mixture should be known. In this paper, the results of laboratory tests and preliminary measurements of the aging effects for monitoring counters are presented. ((orig.))

1994-09-01

113

A new type active personal dosemeter with a solid state detector  

International Nuclear Information System (INIS)

We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.

1988-04-01

114

MOCVD growth of GaAs solar cells on silicon substrates  

Energy Technology Data Exchange (ETDEWEB)

This paper reports advances in the development of solar cells made from GaAs-on-Si structures prepared by metalorganic chemical vapor deposition (MOCVD). The use of concentrator cells, operating at [similar to]200 suns, has led to the efficiency achievements of 21.3% (AM1.5D) for a GaAs-on-Si solar cell, and 27.6 (AM1.5D) for a homoepitaxial GaAs cell. The development of epitaxial multilayer dielectric mirrors (Bragg reflectors), as back-surface reflectors in thin-film GaAs cells, on both Si and GaAs substrates, is shown to lead to modest efficiency increases, over that of conventional designs.

1992-12-01

116

Spectrochemical analysis using infrared multichannel detectors  

CERN Document Server

Spectrochemical analysis using infrared multichannel detectors

2007-01-01

117

CZT Detector and HXI Development at CASS/UCSD  

CERN Document Server

CZT Detector and HXI Development at CASS/UCSD

2006-01-01

118

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)  

CERN Document Server

ACT Lectures on Detectors - Trigger and Data Acquisition (5/5)

2011-01-01

119

SENSITIVITY STUDIES FOR AN IN-SITU PARTIAL DEFECT DETECTOR (PDET) IN SPENT FUEL USING MONTE CARLO TECHNIQUES  

Energy Technology Data Exchange (ETDEWEB)

This study presents results from Monte Carlo radiation transport calculations aimed at characterizing a novel methodology being developed to detect partial defects in Pressurized Water Reactor (PWR) spent fuel assemblies (SFAs). The methodology uses a combination of measured neutron and gamma fields inside a spent fuel assembly in an in-situ condition where no movement of the fuel assembly is required. Previous studies performed on single isolated assemblies resulted in a unique base signature that would change when some of the fuel in the assembly is replaced with dummy fuel. These studies indicate that this signature is still valid in the in-situ condition enhancing the prospect of building a practical tool, Partial Defect Detector (PDET), which can be used in the field for partial defect detection.

2008-04-28

120

Online processing in the ALICE DAQ The detector algorithms  

CERN Document Server

ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). Some specific calibration tasks are performed regularly for each of the 18 ALICE sub-detectors in order to achieve most accurate physics measurements. These procedures involve events analysis in a wide range of experimental conditions, implicating various trigger types, data throughputs, electronics settings, and algorithms, both during short sub-detector standalone runs and long global physics runs. A framework was designed to collect statistics and compute some of the calibration parameters directly online, using resources of the Data Acquisition System (DAQ), and benefiting from its inherent parallel architecture to process events. This system has been used at the experimental area for one year, and includes ...

2010-01-01

121

Neutron scattering studies in the actinide region. Progress report, August 1, 1992--July 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

This report discusses the following topics: Prompt fission neutron energy spectra for {sup 235}U and {sup 239}Pu; Two-parameter measurement of nuclear lifetimes; ``Black`` neutron detector; Data reduction techniques for neutron scattering experiments; Inelastic neutron scattering studies in {sup 197}Au; Elastic and inelastic scattering studies in {sup 239}Pu; and neutron induced defects in silicon dioxide MOS structures.

1993-09-01

122

Wide bandgap collector III-V double heterojunction bipolar transistors  

International Nuclear Information System (INIS)

This thesis is devoted to the study and development of Heterojunction Bipolar Transistors (HBTs) designed for high voltage operation. The work concentrates on the use of wide bandgap III-V semiconductor materials as the collector material and their associated properties influencing breakdown, such as impact ionisation coefficients. The work deals with issues related to incorporating a wide bandgap collector into double heterojunction structures such as conduction band discontinuities at the base-collector junction and results are presented which detail, a number of methods designed to eliminate the effects of such discontinuities. In particular the use of AlGaAs as the base material has been successful in eliminating the conduction band spike at this interface. A method of electrically injecting electrons into the collector has been employed to investigate impact ionisation in GaAs, GaInP and AlInP which has used the intrinsic gain of the ...

123

Photoluminescence linewidths in metalorganic vapor phase epitaxially grown ordered and disordered InAlGaP alloys  

International Nuclear Information System (INIS)

The dependence of the photoluminescent properties of In_0_._4_8(Al_yGa_1_-_y)_0_._5_2P alloys (0#<=#y#<=#0.5) on growth temperature and substrate misorientation off GaAs(100) has been studied. Samples were grown using low-pressure metalorganic vapor phase epitaxy. By studying the dependence of ordering behavior in InGaP as a function of substrate misorientation and growth temperature simultaneously, a very large range in low-temperature photoluminescence emission energy---135 meV---has been obtained. The photoluminescence linewidth exhibits a strong, continuous dependence on the extent of atomic ordering (the emission energy) in the alloys. The results indicate that inhomogeneity in the microstructure of the material (i.e., between ''ordered'' domains and the ''disordered'' matrix) is the dominant photoluminescence broadening mechanism. This investigation has allowed a significant optimization of the optical ...

124

Radon diffusion studies through building construction materials using solid state nuclear track detectors  

International Nuclear Information System (INIS)

Radon appears mainly by diffusion processes from the point of origin following #alpha#- decay of "2"2"6Ra in underground soil and building materials used, in the construction of floors, walls, and ceiling. The transport phenomenon of radon through diffusion is a significant contributor to indoor radon entry. In the present study radon diffusion through sand, cement, mixtures of sand + cement (1:1), sand + cement (2:1), sand + cement (3:1), sand + cement (4:1) has been carried out using LR-115 type II solid state nuclear track detectors (SSNTDs). The radon diffusion coefficient and diffusion lengths have been calculated for different materials. The effect of compaction, which changes the porosity and permeability of the materials, on radon diffusion has also been studied. (author)

2003-10-16

125

Ferromagnetism in Mn-doped GaAs layers: Effects of laser annealing  

Energy Technology Data Exchange (ETDEWEB)

The properties of Mn-doped GaAs layers grown by laser deposition were investigated with measurements of Hall effect and magneto-optical Kerr effect (MOKE). The electrical and magnetic parameters of the layers were defined by growth temperature and quantity of sputtered Mn. It was shown that room-temperature ferromagnetism is revealed by MOKE and, after ruby laser 25 ns pulse annealing, by Hall effect measurements.

2006-05-15

126

GaAs concentrator cell production cost analysis  

Energy Technology Data Exchange (ETDEWEB)

The utilization of GaAs in photovoltaic (PV) applications has been hindered by the cost of substrates and processing. This paper examines the cost effectiveness of GaAs cells for use in concentrator modules when produced at the 10 to 50 MW level per year. Information on costs associated with substrates, epitaxial processing, and subsequent device fabrication will be compared to allowable costs as projected by the US Department of Energy (DOE). The high cot of GaAs solar cells can be mitigated by use of low-cost substrates or high-concentration systems. The costs then can be accommodated when the production level is sufficiently high to take advantage of economies of scale in device processing and substrate price benefits when procured at high volumes. We have found that development of processing equipment, both for the epitaxial growth and device processing, is the key to obtaining production costs consistent with DOE ...

1992-12-01

127

Ultra high-speed (508 MHz) beam position digital feedback system  

Energy Technology Data Exchange (ETDEWEB)

The B-Factory which is constructed by National Laboratory for High Energy Physics is the device for elucidating the breakdown of symmetry of matter and antimatter by studying the behavior of B mesons which are generated in large quantity when the electrons and the positrons which are accelerated to light velocity level are collided. In order to maintain electron beam-positron beam bunch circling the ring at light velocity stably, the instability of the coupled bunch must be overcome. For this purpose, the ultrahigh speed beam position digital feedback control system was developed. This system is composed of the high speed input-output substrate using GaAs LSI, the feedback computation substrate using complementary metal oxide semiconductor and the memory mounted on it, and the real time operation device. The development of both substrates and their functions are explained. The real time data collection and the change of computation parameters ...

1997-02-01

128

Diffusion mechanism of implanted Be in GaAs  

Energy Technology Data Exchange (ETDEWEB)

The transient enhanced diffusion of low and high dose implanted beryllium in undoped gallium arsenide during post-implant rapid thermal annealing in the temperature range of 700-900 C for 60-240 s has been studied and successfully simulated by the kick-out diffusion model, involving singly positively charged Be interstitials and doubly positively charged Ga self-interstitials. Using the ''plus one'' approach for Ga interstitial generation after implantation with the local Ga interstitial sink concept as well as the appropriate initial and boundary conditions for involved mobile species, and taking into account Fermi-level and built-in electric field effects, the obtained partial differential equations have been solved numerically by means of an explicit finite difference method. The thermal equilibrium concentrations and the diffusivities of Be and Ga interstitials, all as a function of temperature, have been deduced from the ...

2008-01-15

129

Application of DLTS method to investigation of deep defect centers in epitaxial layers of multicomponent A"I"I"I-B"V compounds  

International Nuclear Information System (INIS)

The DLTS technique was employed to study deep defect centers in Si doped epitaxial layers of Al_0_._3_7Ga_0_._1_6In_0_._4_7P grown by MOCVD as a part of epitaxial structure GaAs/AlGaInP/GaAs on GaAs substrates. A high concentration of DX centers located in a region near the inverted interface GaAs/Al_0_._3_7Ga_0_._1_6In_0_._4_7P was found. The width of this region with the maximum DX center concentration ranges from 5 to 20 nm. By filling the DX centers in the whole region, the activation energy for electron emission was found to be 0.48 eV. However, it is shown for the first time, that the activation energy of the DX center increases with increasing the distance from the GaAs/Al_0_._3_7Ga_0_._1_6In_0_._4_7P inverted interface. A nonuniform of the DX center concentration on the wafers is also observed. The concentration varies in the range of 1#centre dot#10"1"7 cm"-"3 - 10"1"8 cm"-"3. (author)

130

An accurate high-speed single-electron quantum dot pump  

International Nuclear Information System (INIS)

Using standard microfabrication techniques, it is now possible to construct devices that appear to reliably manipulate electrons one at a time. These devices have potential use as building blocks in quantum computing devices, or as a standard of electrical current derived only from a frequency and the fundamental charge. To date, the error rate in semiconductor 'tuneable-barrier' pump devices, those which show most promise for high-frequency operation, have not been tested in detail. We present high-accuracy measurements of the current from an etched GaAs quantum dot pump, operated at zero source-drain bias voltage with a single ac-modulated gate at 340 MHz driving the pump cycle. By comparison with a reference current derived from primary standards, we show that the electron transfer accuracy is better than 15 parts per million. High-resolution studies of the dependence of the pump current on the quantum dot tuning parameters also reveal ...

2010-07-01

131

A singlet - triplet T_+ based qubit  

International Nuclear Information System (INIS)

We theoretically model a nuclear-state preparation scheme that increases the coherence time of a two-spin qubit in a double quantum dot. The two-electron system is tuned repeatedly across a singlet-triplet level-anticrossing with alternating slow and rapid sweeps of an external bias voltage. Using a Landau-Zener-Stueckelberg model, we find that in addition to a small nuclear polarization that weakly affects the electron spin coherence, the slow sweeps are only partially adiabatic and lead to a weak nuclear spin measurement and a nuclear-state narrowing which prolongs the electron spin coherence. This resolves some open problems brought up by a recent experiment. We also show that the electronic two-spin states singlet and triplet T_+ are promising candidates for the implementation of a qubit in GaAs double quantum dots (DQD). A coherent superposition of the two-spin states is obtained by finite time Landau-Zener-Stueckelberg interferometry and the single qubit ...

2010-03-21

132

In-beam conversion electron spectroscopy using the SACRED array  

International Nuclear Information System (INIS)

Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.

133

Facility for studying photon-neutron reactions under a beam of braking radiation  

International Nuclear Information System (INIS)

A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.

134

Study of point defect detectors in Si  

International Nuclear Information System (INIS)

The importance of point defects in semiconductor and function materials has been studied in detail, but effective means for detecting point defects has not been available for a long time. The end of range defects in Si, produced by 140 keV Ge"+ implantation, were investigated as detectors for measuring the interstitial concentration created by 42 keV B"+ implantation. The concentration of interstitial resulting from the B"+ implantation and the behavior of the interstitial flux under different annealing condition were given. The enhanced diffusion in the boron doped EPI marker, resulting from mobile non-equilibrium interstitials was demonstrated to be transient. Interstitial fluxes arising from processing can be detected by transient enhanced diffusion (TED) of doped marker layers as well

1999-05-01

135

Neutrino cross sections with the MINER?A Experiment  

British Library Electronic Table of Contents (United Kingdom)

MINER?A is a high resolution, fully active detector designed to study neutrino interactions on nuclei in the NuMI beam at Fermi National Accelerator Laboratory. The active volume of the detector consists of 3 tons of plastic scintillator and includes embedded targets of 4He, C, H2O, Fe and Pb. The MINER?A collaboration expects to perform precision, A-dependent neutrino cross section measurements in the 1?10 GeV region, measure the axial form factor, and study nuclear shadowing of F2, quark-hadron duality and coherent pion production, among other topics. MINER?A began data taking in the fall of 2009. This paper describes the MINER?A experiment and provides an overview of the physics objectives along with estimated uncertainties of the measurements and the tentative projected schedule of dat...

2011-01-01

136

Empirical relationship between track diameter and etching time for fission fragments incident on a glass SSNTD at various angles of incidence  

Energy Technology Data Exchange (ETDEWEB)

Geometrical shapes and diameter of nuclear tracks changes continuously during the process of etching for various incident angles. Besides, there is also a marked difference amongst their profiles, as evidenced by the SEM analysis, when the incoming particles fall on the detector at different angles of incidence. This work outlines this aspect of fission fragment tracks in a glass detector and has set out a few empirical relationships between the mean track diameter, d-bar and the etching time, t, within experimental limits. This study, therefore, sheds some light in the follow up the origins and characteristics of heavy ions in some terrestrial and extra-terrestrial materials and also in studying the collimation accuracy of heavy ion bombardments. The implications of the results in discerning the measurements of incident angles of various types of ions are described in detail in the paper.

1983-09-01

137

TIARA: A large solid angle silicon array for direct reaction studies with radioactive beams  

International Nuclear Information System (INIS)

A compact, quasi-4? position sensitive silicon array, TIARA, designed to study direct reactions induced by radioactive beams in inverse kinematics is described here. The Transfer and Inelastic All-angle Reaction Array (TIARA) consists of 8 resistive charge division detectors forming an octagonal barrel around the target and a set of double-sided silicon-strip annular detectors positioned at each end of the barrel. The detector was coupled to the ?-ray array EXOGAM and the spectrometer VAMOS at the GANIL Laboratory to demonstrate the potential of such an apparatus with radioactive beams. The 14N(d,p)15N reaction, well known in direct kinematics, has been carried out in inverse kinematics for that purpose. The observation of the 15N ground state and excited states at 7.16 and 7.86 MeV is presented here as well as the comparison of the measured proton angular distributions with DWBA calculations. ...

2010-03-11

138

Study of core collapse neutrino signals and constraints on neutrino masses from a future Galactic Supernova  

CERN Document Server

We study the sensitivity to neutrino masses of a Galactic supernova neutrino signal as could be measured with the detectors presently in operation and with future large volume water \\v{C}erencov and scintillator detectors. The analysis uses the full statistics of neutrino events. The method proposed uses the principles of Bayesian inference reasoning and has shown a remarkably independence of astrophysical assumptions. We show that, after accounting for the uncertainties in the detailed astrophysical description of the neutrino signal and taking into account the effects of neutrino oscillations in the supernova mantle, detectors presently in operation can have enough sensitivity to reveal a neutrino mass (or to set upper limits) at the level of 1 eV. This is sensibly better than present results from tritium $\\beta$-decay experiments, competitive with the most conservative limits from neutrinoless ...

2005-01-01

139

Radiation hardness of plastic scintillating fiber against fast neutron and #gamma#-ray irradiation  

International Nuclear Information System (INIS)

In future collider experiments, where a background radiation level is estimated to be very high, e.g. around 10"2 #approx# 10"5 Gy/yr and 10"1"1 #approx# 10"1"4 n/cm"2/yr at SSC, the detectors operating around the collision point in the experiments will encounter a considerable amount of radiation. Therefore, the detectors, especially the calorimeter, are required to be resistive against high radiation levels. From this point of view, it is of great importance to study the effects of radiation damage on the performance of the detectors. The authors report preliminary results of measurements of radiation hardness of the plastic scintillating fiber Kuraray SCSF-81 against irradiation with fast neutrons and "6"0Co #gamma#-rays in the region of the neutron fluence from 1 x 10"1"1 to 5 x 10"1"3 n/cm"2 and the integrated #gamma#-ray dose from 890 to 10"5 Gy, respectively. Deterioration of both intrinsic light ...

1992-10-25

140

Launch of the Space experiment PAMELA  

CERN Document Server

PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline to reject false ...

2007-01-01

141

Basic study of entire whole-body PET scanners based on the OpenPET geometry  

International Nuclear Information System (INIS)

A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into ...

2010-09-01

142

Optimization of doubly Q-switched lasers with both an acousto-optic modulator and a GaAs saturable absorber  

Science.gov (United States)

A doubly Q-switched laser with both an acousto-optic (AO) modulator and a GaAs saturable absorber can obtain a more symmetric and shorter pulse with high pulse peak power, which has been experimentally proved. The key parameters of an optimally coupled doubly Q-switched laser with both an AO modulator and a GaAs saturable absorber are determined, and a group of general curves are generated for what we believe is the first time, when the single-photon absorption (SPA) and two-photon absorption (TPA) processes of GaAs are combined, and the Gaussian spatial distributions of the intracavity photon density and the initial population-inversion density as well as the influence of the AO Q-switch are considered. These key parameters include the optimal normalized coupling parameter, the optimal normalized GaAs saturable absorber parameters, and the normalized parameters of the AO Q-switch, which can maximize ...

2007-08-20

143
148

Small world when building a particle detector prototype, the devil is in the tiny details  

CERN Multimedia

Small world when building a particle detector prototype, the devil is in the tiny details

2004-01-01

149

Photodiode Scintillation Detector for Anti-Coincidence Shielding  

Science.gov (United States)

Photodiode Scintillation Detector for Anticoincidence Shielding An important goal of space research is to understand the physics involved in the activity of ...

150

Radiation tolerant GaAs MESFET with a highly-doped thin active layer grown by OMVPE  

International Nuclear Information System (INIS)

A new structure of GaAs MESFET with high radiation tolerance is proposed. Changes in electrical parameters of a GaAs MESFET as a function of total #gamma#-ray dose have been found to be caused mainly by a decrease in the effective carrier concentration in an active layer. The authors have designed a new structure from a simulation based on an empirical relationship between the changes of the effective carrier concentration and the total #gamma#-ray dose. It has been successfully demonstrated by utilizing a highly-doped thin active layer (4 x 10"1"8 cm"-"3, 100 Angstrom) grown by OMVPE. This MESFET can withstand a dose ten times higher [1 x 10"9 rads(GaAs)] than a conventional one can.

1990-07-16

151

Metastable one- and two-electron donor states in GaAs and CdF{sub 2}  

Energy Technology Data Exchange (ETDEWEB)

The strongly localized one-electron (D{sup 0}) and two-electron (D{sup -}) donor states are considered with the lattice deformation around the donor center taken into account. For GaAs, donor energy levels have been calculated as functions of the hydrostatic pressure. The calculated energy positions and pressure coefficients agree with the experimental data. It is shown that the interaction with phonons reduces the probability of radiative transitions between the states of different localization and leads to the metastability of shallow-level donor states with respect to the D{sup -} state in GaAs and both the states (D{sup 0} and D{sup -}) in CdF{sub 2}. (author) 7 refs, 1 fig

1996-12-31

152

5 GHz GaAs monolithic astable multivibrator type voltage controlled oscillator  

Science.gov (United States)

A 5 GHz GaAs monolithic astable multivibrator-type voltage-controlled oscillator has been developed. The monolithic oscillator uses 2 micron long self-aligned TiW-silicide gate MESFETs as well as GaAs Schottky diodes for capacitance. Good agreement between the experiment and calculations for oscillation frequency characteristics versus control voltage is obtained by assuming donor density in the FET active layer to be a Gaussian distribution. This oscillator is useful for monolithic front ends and phase-locked oscillators used in microwave signal processing. X-band oscillation frequency can be obtained with 1 micron long gate FET and low loss resonance inductors.

1984-03-01

153

Year-long comparison of two techniques to monitor outdoor radon concentrations at Shiprock, New Mexico  

Energy Technology Data Exchange (ETDEWEB)

The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was ...

1988-08-01

154

Results from Amanda  

Energy Technology Data Exchange (ETDEWEB)

In this report we present an update on the results from the Amanda-B10 detector which operated in 1997 at depths of 1500 to 2000 meters in the deep Antarctic ice. The goal of Amanda project is to search for extra-terrestrial neutrinos. As a precursor to such a search we have studied atmospheric neutrinos which act as a calibration source for the detector. The observation of atmospheric neutrinos at a rate consistent with Monte-Carlo predictions establishes Amanda-B10 as a neutrino telescope. The Amanda-B10 data has been searched for evidence of several classes of neutrinos and for magnetic monopoles. Searches for a diffuse high energy neutrino flux and for neutrinos in coincidence with gamma-ray bursts have been conducted. Preliminary data analyses show no excess of neutrinos has been found. (A.C.)

2001-07-01

155

Performance of a Bragg curve detector for heavy ion identification  

Energy Technology Data Exchange (ETDEWEB)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.

1982-12-15

156

Performance of a Bragg curve detector for heavy ion identification  

International Nuclear Information System (INIS)

By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).

157

Non-standard antineutrino interactions at Daya Bay  

CERN Document Server

We study the prospects of pinning down the effects of non-standard antineutrino interactions in the source and in the detector at the Daya Bay neutrino facility. It is well known that if the non-standard interactions in the detection process are of the same type as those in the production, their net effect can be subsumed into a mere shift in the measured value of the leptonic mixing angle theta_13. Relaxing this assumption, the ratio of the antineutrino spectra measured by the Daya Bay far and near detectors is distorted in a characteristic way, and good fits based on the standard oscillation hypothesis are no longer viable. We show that, under certain conditions, three years of Daya Bay running can be sufficient to provide a clear hint of non-standard neutrino physics.

2011-01-01

158

Determination of radon and thoron permeability through some plastics by track technique  

Energy Technology Data Exchange (ETDEWEB)

Experiments have been performed to study the usefulness of several types of plastic foils as filter to separate radon and thoron. Time-integrated alpha-activity measurements have been carried out by using the so-called ''can-technique'' equipped with both LR-115 and CR-39 track detectors. The track density observed on the detectors, taken as a measure of radon activity concentration, has been determined as a function of the thickness of filter foils. The radon permeability and the thoron separation factors have been determined. It is shown that various plastic foils exhibit considerable differences in radon diffusion coefficient owing to their different chemical structures. Among the plastic foils investigated the polyethylene proved to have the highest gas diffusion coefficient.

1986-01-01

159

Conceptual design of a low-temperature radiation-hard tracker detector  

CERN Document Server

Silicon sensors have about ten times improved radiation hardness around 130 K temperature, compared with the state-of-art sensors close to room temperature. This is based on the Lazarus effect studied by the RD39 Collaboration of CERN. Other benefits of low temperatures will also be discussed. We shall describe the conceptual design of low-mass detector modules cooled using two-phase flow of argon in miniature cooling pipes integrated in the module structure between the sensors and the readout hybrid circuit. The main engineering features of the cooling system and mechanical support structures are discussed, as well as the benefits arising from the operation of the tracker under cryogenic vacuum. 4 Refs.

2003-01-01

160

Spectroscopy of Neutron-Rich Nuclei with the CLARA-PRISMA Setup  

International Nuclear Information System (INIS)

The CLARA-PRISMA setup, composed of an array of 25 Clover detectors placed at the target position of the magnetic spectrometer PRISMA, has recently concluded its campaign to study the structure of moderately neutron-rich nuclei. In this contribution, results obtained in the vicinity of the doubly-magic nucleus "4"8Ca are presented, together with results obtained for the heavy iron isotopes. The perspectives offered by the forthcoming operation of the AGATA Demonstrator Array coupled to PRISMA are also discussed. (author)

2009-03-01

161

Resolution studies of a GEM-based TPC  

Energy Technology Data Exchange (ETDEWEB)

Currently there are four different concept studies trying to optimise the detector for the requirements at the ILC. In three of these detector concepts a time projection chamber (TPC) is foreseen as the main tracking device. To achieve the intended spatial resolution of 100 {mu}m, micro pattern gas detectors (MPGD) are considered for gas amplification. The two different MPGDs discussed for the ILC TPC are Micro-Mesh Gaseous Detectors (Micromegas) and Gas Electron Multiplier foils (GEMs). The current thesis shows resolution studies with a TPC prototype equipped with a triple GEM readout structure. A hodoscope made up of silicon strip sensors gives a precision reference track, allowing an unbiased measurement of the spatial resolution. High statistics measurements have been conducted at the DESY test beam facility, which provides positrons with a tunable energy ...

2006-12-15

162

Experimental studies of compact real-time neutron dosimeters  

International Nuclear Information System (INIS)

Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential ...

2008-06-01

163

Estimation of errors provided with dead times of roentgen digital tomography  

International Nuclear Information System (INIS)

Impact of apparatus dead time on the accuracy of measurement of radial distribution of the radiation attenuation factor in the roentgen computer tomography for rotation bodies is studied. Analytical expressions are obtained. Calculations of the threshold loads for radiometric detectors, providing for the accuracy of measurement at the stage of designing the tomographic complex detecting unit, are obtained

164

Cylindrical drift chamber with three-dimensional data readout  

International Nuclear Information System (INIS)

A multiwire cylindrical drift chamber is the main detector of the AMPIR 4#pi#-spectrometer for studying pion-nucleon reactions. The chamber has possibility to measure three coordinates by the electron drift time and by the charge division method. Chamber design and geometry, test bench, readout electronics and also results of calculations, simulation and tests are described.

165

Cylinder drift chamber with three-dimensional data output  

Science.gov (United States)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4{pi} acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

1995-03-01

166

Cylinder drift chamber with three-dimensional data output  

International Nuclear Information System (INIS)

A cylindrical multiwire drift chamber is the central detector of the AMPIR spectrometer. It has 4#pi# acceptance angle and was designed to study pion-nucleon reactions. The chamber can determine the three coordinates through the electron drift time and charge division ration. The paper describes the layout and design of the chamber, the test bench, the data output circuit, the design parameters, and the results of computer simulations and tests.

167

Anomalous solvent extraction behavior of astatine  

International Nuclear Information System (INIS)

We studied the solvent extraction behavior of astatine and found the anomalous behavior of this element similar to radioiodine. Astatine was extracted into CS_2 from acidic solution over a wide range of carrier iodine concentration. The distribution ratios of astatine were determined by measuring the #gamma#-ray from 210 At with a NaI(Tl) detector. A drastic change was observed around at 10"-"4 mol/l as in the case of 131 l. This tendency is well explained by the kinematics of the chemical reactions concerned. (author).

168

ATLAS tile calorimeter electronics upgrade  

CERN Document Server

This presentation summarizes the present upgrade R&D projects in the TileCal collaboration. One project studies the possibility to divide the drawers into smaller minidrawers to simplify maintenance. There are three different front-end projects. There are also projects dealing with high voltage and low voltage distribution, projects for developing PMT dividers, low voltage electronics, data transmission and off-detector electronics.

2011-01-01

169

Track Reconstruction and Performance of DRIFT Directional Dark Matter Detectors using Alpha Particles  

CERN Document Server

First results are presented from an analysis of data from the DRIFT-IIa and DRIFT-IIb directional dark matter detectors at Boulby Mine in which alpha particle tracks were reconstructed and used to characterise detector performance--an important step towards optimising directional technology. The drift velocity in DRIFT-IIa was [59.3 +/- 0.2 (stat) +/- 7.5 (sys)] m/s based on an analysis of naturally-occurring alpha-emitting background. The drift velocity in DRIFT-IIb was [57 +/- 1 (stat) +/- 3 (sys)] m/s determined by the analysis of alpha particle tracks from a Po-210 source. 3D range reconstruction and energy spectra were used to identify alpha particles from the decay of Rn-222, Po-218, Rn-220 and Po-216. This study found that (22 +/- 2)% of Po-218 progeny (from Rn-222 decay) are produced with no net charge in 40 Torr CS2. For Po-216 progeny (from Rn-220 decay) the uncharged fraction is (100 +0 -35)%.

2007-01-01

170

Research in heavy-ion nuclear physics. [Dept. of Physics and Astronomy, The Univ. of Kansas, Lawrence, Kansas  

Energy Technology Data Exchange (ETDEWEB)

Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to [sup 47]V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of [sup 28]Al through three different entrance channels. Angular distributions are shown for different mass channels of the [sup 29]Si+[sup 27]Al reaction at E[sub lab] = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the [sup 24]Mg+[sup 24]Mg reaction; cross sections for binary fragment emission are shown for E[sub lab] = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.

1992-01-01

171

Research in heavy-ion nuclear physics. Annual progress report, May 1, 1992--April 30, 1993  

Energy Technology Data Exchange (ETDEWEB)

Attention was focused on the fission process in light nuclear systems. A model calculation based on the transition-state model of nuclear fission was applied to {sup 47}V fission as populated through multiple entrance channels and to fusion-fission cross sections for production of {sup 28}Al through three different entrance channels. Angular distributions are shown for different mass channels of the {sup 29}Si+{sup 27}Al reaction at E{sub lab} = 125 MeV. Pronounced structure is seen in the symmetric and near-symmetric fission channels from the {sup 24}Mg+{sup 24}Mg reaction; cross sections for binary fragment emission are shown for E{sub lab} = 90 MeV. A large Bragg-curve detector was used in this experiment. Ways to optimize detector response were studied; in addition, the Bragg detector was instrumented with an internal position-sensitive multiwire proportional counter.

1992-01-01

172

MicroDiffraction in the Scanning Electron Microscope (SEM)  

Science.gov (United States)

The identification of crystallographic phases in the scanning electron microscope (SEM) has been limited by the lack of a simple way to obtain electron diffraction data of an unknown while observing the micro structure of the specimen. With the development of Charge Coupled Device (CCD) based detectors, backscattered electron Kikuchi patterns (BEKP), alternately referred to as electron backscattered diffraction patterns (EBSP), can be easily collected. Previously, BEKP has been limited to crystallographic orientation studies due to the poor pattern quality collected with video rate detector systems. With CCD detectors, a typical BEKP can now be acquired from a micron or sub-micron-sized crystal using an exposure time of 1-10 seconds with an accelerating voltage of 10-40 kV and a beam current as low as 0.1 nA. Crystallographic phase analysis using BEKP is unique in that the properly equipped SEM permits ...

1997-12-31

173

Development of a phoswich detector to detect neutrons in the charged-particle mixed field  

Energy Technology Data Exchange (ETDEWEB)

Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on board a spacecraft, because the neutron measurement requires to discriminate ...

1997-07-01

174

Body weight-tailored contrast material injection protocol for 64-detector row computed tomography coronary angiography  

International Nuclear Information System (INIS)

The aim of this study was to assess the body weight-tailored contrast material injection protocol for 64-detector computed tomography (CT) to maintain optimal coronary CT attenuation. A total of 60 patients who underwent CT coronary angiography were assigned to one of three groups: protocol A, total of 0.7 ml kg"-"1 with 300 mg I/ml iodine concentration; protocol B, total of 0.6 ml kg"-"1 with 350 mg I/ml; protocol C, total of 0.7 ml kg"-"1 with 350 mg I/ml. The injection duration was 10 s in all patients. The proportion of intracoronary attenuation values >325 Hounsfield unit (HU) was compared on a per-vessel and per-patient basis. The attenuation value was significantly more likely to exceed 325 HU with protocol C (95% for reader 1 and 90% for reader 2) than with protocol A or B on the per-vessel analysis (P325 HU) with 64-detector CT when using an injection duration of 10 s. (author)

2011-01-01

175

Accelerator related background in the CMS detector at LHC  

International Nuclear Information System (INIS)

Complete calculations of the accelerator related background in the muon spectrometer of the CMS detector at the Large Hadron Collider are presented. The simulations have been performed with the STRUCT multi-turn tracking code and the MARS and FLUKA cascade codes taking into account latest information of the LHC lattice, vacuum conditions, beam cleaning system and the shielding and layout of the CMS experiment. Beam loss distributions in the interaction regions and their vicinities and their contribution to the background levels in the muon spectrometer of CMS are analyzed. The studies show that hadronic and electromagnetic components of machine background are efficiently suppressed by the proposed CMS shielding. High energy muons penetrate through the shielding, but in positions of significance they do not contribute more than a few percent compared to the background generated by the pp-collisions. It is anticipated that the relative ...

176

Quality assurance program for LR 115 based radon concentration measurements in a case-control study: description and results  

International Nuclear Information System (INIS)

A case-control study on lung cancer and radon exposure in dwellings has been carried out in Lazio, a high indoor radon region of Central Italy. A total of about 400 cases and 400 controls were recruited and radon concentration was measured in a total of about 1850 dwellings. In each dwelling, radon concentration measurement devices were placed in both the main bedroom and living room for two consecutive six-month periods. Each radon device, enclosed in a sealed polyethylene bag, contains two LR 115 detectors, each being covered by a thin absorber to reduce the alpha-energy within the detector sensitive range. A quality assurance program, described in this paper, was applied in order to reduce radon concentration measurement uncertainty, which have a significant impact on the results of an epidemiological study. The reported internal quality control and intercomparison results are compared with the ...

2003-06-01

177

High Efficiency Thin-Fili, GaAs Solar Cells - NASA Technical ...  

Science.gov (United States)

Metal-Semiconductor Solar Cells," J. Appl. Phys. 46,. 1286 (1975). 12) H. B. Kim , G. G. Sweeney and I. S. Heng, "Analysis of ...

178

GaAs REI,IABILITY DATARASE '-r. SACCO, S . C+ ON Z, AItIli ...  

Science.gov (United States)

Direct coupljng between Al and Au metal]jzations can result in an increase in gate resistance due to a metallurgical reaction. (purple plague). An RF life test on ...

179

Development of GaInAsP for GaInAsP/Ge cascade solar cells  

Energy Technology Data Exchange (ETDEWEB)

Quaternary semiconductor compounds are ideal candidates for use in monolithic cascade solar cells because the lattice constant and the bandgap of such compounds can be independently varied. The quaternary semiconductor compound Ga[sub 0.83]In[sub 0.17]As[sub 0.67]P[sub 0.33] not only is lattice matched to GaAs and Ge but also provides a current matched top cell for the GaInAsP/Ge monolithic cascade solar cell. Under concentration of 100 suns, the projected efficiency for such a cell is about 34%. The growth of Ga[sub 0.83]In[sub 0.17]As[sub 0.67]P[sub 0.33] lattice matched to GaAs and Ge has been demonstrated. GaInAsP solar cells have been grown on both GaAs and Ge substrates. A GaInAsP on GaAs solar cell with an active area efficiency of 23.2% for 1 sun, AM 1.5 direct illumination has been prepared. A proposed structure for the GaInAsP/Ge cascade cell is also given.

1992-12-01

180

Review of the application of molecular beam epitaxy for high efficiency solar cell research  

Energy Technology Data Exchange (ETDEWEB)

In the last two years, rapid progress has been made in the energy conversion efficiencies of GaAs solar cells fabricated from molecular beam epitaxy (MBE) material. The efficiencies of cells fabricated from MBE material are now comparable with those fabricated from metal-organic chemical vapor deposition material, even for cells of dimension 2 cmx4 cm. This paper reviews the progress in MBE cell efficiencies. Also discussed is the role oval defects play in GaAs diode and solar cell performance. (orig.).

1991-05-01

181

High-optical-quality GaInP and GaInP/AlInP double heterostructure lasers grown on GaAs substrates by gas-source molecular-beam epitaxy  

Science.gov (United States)

By gas-source molecular-beam epitaxy, we obtained a device-quality GaInP epitaxial layer lattice matched to (100)-GaAs substrates, with a photoluminescence efficiency comparable to that of a crystal grown by liquid-phase epitaxy. A GaInP/AlInP double heterostructure laser with a GaInP active layer was fabricated, and pulsed lasing operation was achieved at room temperature for, we believe, the first time.

1989-11-01

182

Pre-Flight Development of the PoGOLite Pathfinder  

International Nuclear Information System (INIS)

The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent ...

183

Construction of the ATLAS end cap electromagnetic calorimeter and study of its performances; Construction du bouchon du calorimetre electromagnetique d'ATLAS et etudes de ses performances  

Energy Technology Data Exchange (ETDEWEB)

ATLAS is one of the four experiments which will take place at the LHC, the CERN future protons collider. This accelerator, which should start in 2007, will allow to continue the studies carried out by its predecessors, as the standard model Higgs boson and new physics searches. The very high luminosity -10 fb{sup -1} during the first three functioning years, then 100 fb{sup -1}- and the 14 TeV in the frame center will ease these studies. The Centre de Physique des Particules de Marseille took part in the ATLAS collaboration, taking in charge half of the End-cap electromagnetic calorimeter modules construction. The description of this sub-detector and the construction steps, in particular the electrical tests which allow the stacking validation, are presented in this document. These tests results, obtained for the live first production modules, are analysed. The pre-series module (module 0) performances, obtained with beam ...

2002-09-01

184

Technical design aspects of Feasibility Study-II  

Energy Technology Data Exchange (ETDEWEB)

Feasibility Study-II examined a high-performance Neutrino Factory providing 1 x 10{sup 20} neutrinos per year aimed at a long-baseline detector. The Study was sponsored jointly by BNL and the Neutrino Factory and Muon Collider Collaboration ration (MC) and is based on a 1 MW proton driver operating at 24 GeV, i.e., an upgraded version of the AGS accelerator. Compared with the earlier FNAL-sponsored study (Feasibility Study-I), there is a sixfold improvement in performance. Here we describe details of the implementation of Study-II concepts and discuss their efficacy. Alternative approaches that will be pursued in follow-on R and D activities are also described briefly.

2001-08-15

185

Studies of the applicability of opto-electronic devices for instrumentation in high-energy physics. Progress report, June 1, 1981-May 31, 1982  

Energy Technology Data Exchange (ETDEWEB)

Instrumentation research to study the feasibility of using optical data processing techniques to solve real-time pattern recognition problems for high energy physics experiments is now in its second year. During the past year, a prototype optical processor for use in BNL Experiment 702 was conceived and designed, using test data from the experiment and simulating the optical processor in the computer. A number of technical studies have been made, mostly relating to the selection of the optical filter for the processor. Comparisons between natural and synthetic holograms, both bleached and unbleached, have been made. We conclude from these tests that the kinoform, a computer-generated phase hologram, is the optimal choice for this processor. A new method for producing the kinoform has been tried by this group with encouraging results. The optical design for the prototype processor is complete, and the required optical elements, sources, and the ...

1982-01-01

186

Operation of an 18-fold segmented n-type HPGe detector in liquid nitrogen  

International Nuclear Information System (INIS)

For the first time a segmented n-type HPGe detector was operated directly submerged in liquid nitrogen over a long period. As this kind of detector is envisioned to be used in GERDA phase II, it was operated with a low mass signal cable with snap-contacts and mounted in a low-mass copper holder. The detector performance was stable over 146 days, indicating that neither detector nor contacts deteriorated.

2009-11-01

187

From tomography to voludensitometry: radiation detectors for industrial control and medical instrumentation; De la tomographie a la voludensitometrie: les capteurs pour le controle industriel et l`instrumentation medicale  

Energy Technology Data Exchange (ETDEWEB)

In this article, the author presents the main technological solutions, available or in development, on X-ray detectors in order to obtain a digital image in biomedical radiography or in industrial radiography: linear x-ray detectors and bidimensional x-ray detectors (memory radioluminescent screens, matrix plan detectors).

1993-12-01

188

Bragg curve spectroscopy detector for particle identification  

International Nuclear Information System (INIS)

The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.

189

Quantitative imaging of turbulent and reacting flows  

Energy Technology Data Exchange (ETDEWEB)

Quantitative digital imaging, using planar laser light scattering techniques is being developed for the analysis of turbulent and reacting flows. Quantitative image data, implying both a direct relation to flowfield variables as well as sufficient signal and spatial dynamic range, can be readily processed to yield two-dimensional distributions of flowfield scalars and in turn two-dimensional images of gradients and turbulence scales. Much of the development of imaging techniques to date has concentrated on understanding the requisite molecular spectroscopy and collision dynamics to be able to determine how flowfield variable information is encoded into the measured signal. From this standpoint the image is seen as a collection of single point measurements. The present effort aims at realizing necessary improvements in signal and spatial dynamic range, signal-to-noise ratio and spatial resolution in the imaging system as well as developing excitation/detection strategies which provide ...

1993-12-01

190

Pulse height response of Si surface barrier detectors to 5-70 MeV heavy ions  

Energy Technology Data Exchange (ETDEWEB)

An extensive series of pulse height measurements have been performed in partially depleted Si surface barrier detectors, using various heavy ions (Li, B, C, O, Al and Cl), at energies between 5 and 70 MeV. After correcting for the small energy loss of the incident ions in traversing the gold surface barrier layer of the detector and for the residual nuclear stopping, the resulting pulse heights per MeV for the various heavy ions were found to be up to 2.5% larger than for the {sup 241}Am (5.486 MeV) alpha particle. This increase, although significant, is smaller than had been anticipated from an extrapolation of the earlier study of H, He and Li pulse heights by Lennard et al.. A new method of analysis of pulse height data, which significantly reduces the uncertainties associated with the dead layer energy loss and nuclear stopping corrections, was used in order to determine directly the variation of the average energy for ...

1992-04-01

191

Quasiparticle band structure of thirteen semiconductors and insulators  

Science.gov (United States)

By using a model dielectric matrix in electron self-energy evaluations the computational effort of a quasiparticle band-structure calculation for a semiconductor is greatly reduced. Applications to various systems with or without inversion symmetry, having narrow or wide band gaps, and semiconductor alloys demonstrate the reliability and accuracy of the method. Calculations have been performed for thirteen semiconducting or insulating materials: Si, LiCl, AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, InSb, and the Al{sub 0.5}Ga{sub 0.5}As and In{sub 0.53}Ga{sub 0.47}As alloys. Excellent agreement with experimental results is obtained for the quasiparticle energies for these materials. The only three exceptions, {ital E}({Gamma}{sub 1{ital c}}) of AlP, {ital E}({ital L}{sub 1{ital c}}) of AlAs, and {ital E}({ital L}{sub 1{ital c}}) of AlSb are discussed and attributed to various experimental uncertainties. Several other quasiparticle-excitation-related properties are ...

1991-06-15

192

Quasiparticle band structure of thirteen semiconductors and insulators  

International Nuclear Information System (INIS)

By using a model dielectric matrix in electron self-energy evaluations the computational effort of a quasiparticle band-structure calculation for a semiconductor is greatly reduced. Applications to various systems with or without inversion symmetry, having narrow or wide band gaps, and semiconductor alloys demonstrate the reliability and accuracy of the method. Calculations have been performed for thirteen semiconducting or insulating materials: Si, LiCl, AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, InSb, and the Al_0_._5Ga_0_._5As and In_0_._5_3Ga_0_._4_7As alloys. Excellent agreement with experimental results is obtained for the quasiparticle energies for these materials. The only three exceptions, E(#GAMMA#_1_c) of AlP, E(L_1_c) of AlAs, and E(L_1_c) of AlSb are discussed and attributed to various experimental uncertainties. Several other quasiparticle-excitation-related properties are also examined in this work. The many-body corrections to the eigenvalues of ...

193

Photoluminescence linewidths in metalorganic vapor phase epitaxially grown ordered and disordered InAlGaP alloys  

Science.gov (United States)

The dependence of the photoluminescent properties of In{sub 0.48}(Al{sub {ital y}}Ga{sub 1{minus}{ital y}}){sub 0.52}P alloys (0{le}{ital y}{le}0.5) on growth temperature and substrate misorientation off GaAs(100) has been studied. Samples were grown using low-pressure metalorganic vapor phase epitaxy. By studying the dependence of ordering behavior in InGaP as a function of substrate misorientation and growth temperature simultaneously, a very large range in low-temperature photoluminescence emission energy---135 meV---has been obtained. The photoluminescence linewidth exhibits a strong, continuous dependence on the extent of atomic ordering (the emission energy) in the alloys. The results indicate that inhomogeneity in the microstructure of the material (i.e., between ordered'' domains and the disordered'' matrix) is the dominant photoluminescence broadening mechanism. This ...

1992-12-01

194

Photoluminescence linewidths in metalorganic vapor phase epitaxially grown ordered and disordered InAlGaP alloys  

Energy Technology Data Exchange (ETDEWEB)

The dependence of the photoluminescent properties of In{sub 0.48}(Al{sub {ital y}}Ga{sub 1{minus}{ital y}}){sub 0.52}P alloys (0{le}{ital y}{le}0.5) on growth temperature and substrate misorientation off GaAs(100) has been studied. Samples were grown using low-pressure metalorganic vapor phase epitaxy. By studying the dependence of ordering behavior in InGaP as a function of substrate misorientation and growth temperature simultaneously, a very large range in low-temperature photoluminescence emission energy---135 meV---has been obtained. The photoluminescence linewidth exhibits a strong, continuous dependence on the extent of atomic ordering (the emission energy) in the alloys. The results indicate that inhomogeneity in the microstructure of the material (i.e., between ordered'' domains and the disordered'' matrix) is the dominant photoluminescence broadening mechanism. This ...

1992-12-01

195

A satellite born charged particles telescope for the study of cosmic ray nuclei  

Energy Technology Data Exchange (ETDEWEB)

The description of the high energy particle telescope NINA for the study of cosmic ray nuclei is presented. The instrument will be installed on board of the Resource 01 satellite and will fly on a polar orbit at 690 Km. The telescope consists on a pile of 16 detecting planes each of them is composed by two silicon strip detectors with perpendicular strips and has a total area of 60x60mm{sup 2}. The experiment goals are the study of cosmic ray protons and nuclei in the energy range 12-100 MeV/amu. It will be sensitive to the anomalous component and will also make the observation of the large solar flare events and geophysical phenomena as well. This experiment is the first step of the program RIM whose goal is the satellite study of anti particles in primary cosmic rays.

1995-09-01

196

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.

2010-01-01

197

First Measurements of the Inclined Boron Layer Thermal-Neutron Detector for Reflectometry  

Energy Technology Data Exchange (ETDEWEB)

A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.

2008-10-01

198

Radiochemical detector cross section sensitivity studies in the A approx. = 90 mass region  

Energy Technology Data Exchange (ETDEWEB)

The use of radiochemical detectors in the A approx. = 90 mass region to measure 14 MeV neutron fluences is investigated from the standpoint of cross section sensitivities. Specifically, /sup 90/Zr and /sup 89/Y neutron-induced cascades leading to the production of /sup 89/Zr, /sup 88/Zr, /sup 88/Y, and /sup 87/Y are studied in a one-energy-group approximation, and the sensitivities of the measured ratios R/sub Z/ = /sup 88/Zr//sup 89/Zr and R/sub Y/ = /sup 87/Y//sup 88/Y to the input cross sections are delineated. The most sensitive cross section in each cascade is the cross section that dominates the production of the final isotope in the chain. Only one of the isomeric levels in /sup 90/Zr contributes importantly to the Zr cascade. Burnback (n,..gamma..) and burnup (n,p) reactions are also considered. The (n,..gamma..) effects are small, but (n,p) effects can be substantial due to low energy enhancements of (n,p) cross sections in the ...

1984-04-05

199

Gamma Radiation Detectors of the TA-55 Waste Line Monitoring System  

Energy Technology Data Exchange (ETDEWEB)

This report covers the gamma detectors, measurement instrumentation, and testing results of a system developed at Los Alamos National Laboratory. This system monitors the process liquid waste streams at the Plutonium Facility (TA-55) for the presence of radioactive contamination. The detectors are at various points on the acid, caustic, and industrial waste lines. Two of the detectors are on the sanitary sewer lines from the facility. A custom interface unit associated with these two detectors furnishes the facility operation center with a notification of the detection of material. All of the detectors furnish measurement information to a central computer system for storage and trending.

1999-06-01

200

First results from the Lund NMP particle detector system  

International Nuclear Information System (INIS)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-06-15

201

First results from the Lund NMP particle detector system  

British Library Electronic Table of Contents (United Kingdom)

The design and first results from a Double Sided Silicon Strip Detector (DSSSD) recently installed at the Lund Nuclear Microprobe facility (NMP) are presented. The detector has 64 sector strips and 32 ring strips, which in combination give more than 2000 detector cells, each with characteristics comparable with a standard surface barrier detector (SBD). The detector has been tested both with radioactive sources and with different ion beams and energies. The most striking features are the high rate virtually pile-up free operation and also the possibility of detailed measurement of angular distributions.

2009-01-01

202

The 8{pi}LP Project: A 4{pi} light charged particle detection array at LNL  

Energy Technology Data Exchange (ETDEWEB)

A 4{pi} detection system sensitive to light charged particles is being developed at the Laboratori Nazionali di Legnaro (LNL) for the study of reaction mechanisms at energies up to 20 AMeV. The array consists of 262 {Delta}E-E telescopes covering 90% of 4{pi}. Each telescope is made of a 300 {mu}m passivated silicon detector and a 15 mm (or 5 mm) CsI(Tl) crystal read by a photodiode. The system will be operational in the Spring of 1997 and the first experiments will run in the second half of 1997.

1996-12-31

203

Non-Standard Interaction Effects at Reactor Neutrino Experiments  

CERN Document Server

We study non-standard interactions (NSIs) at reactor neutrino experiments, and in particular, the mimicking effects on \\theta_13. We present generic formulas for oscillation probabilities including NSIs from sources and detectors. Instructive mappings between the fundamental leptonic mixing parameters and the effective leptonic mixing parameters are established. In addition, NSI corrections to the mixing angles \\theta_13 and \\theta_12 are discussed in detailed. Finally, we show that, even for a vanishing \\theta_13, an oscillation phenomenon may still be observed in future short baseline reactor neutrino experiments, such as Double Chooz and Daya Bay, due to the existences of NSIs.

2008-01-01

204

Neutron resonances in /sup 100/Mo and valence neutron capture  

Science.gov (United States)

Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

1979-07-01

205

Neutron activation analysis of trace elements in Japanese hormesis cosmetics  

International Nuclear Information System (INIS)

In Japan, cosmetics claiming hormesis effect are available through Internet. Although these cosmetics show the contents, they never mention the minor elements and radioactive sources. The existence of radioisotopes, however, was observed by measurements of the gamma-rays with a HPGe detector. In this study, in order to clarify the contents of trace elements, the hormesis cosmetics including radioactive sources were analyzed using INAA, PGAA and NAA with multiple gamma-ray detection (NAAMG). Nineteen elements were analyzed quantitatively in hormesis cosmetics by INAA, PGAA and NAAMG and 16 elements were detected qualitatively by SEM-EPMA. (author)

2008-12-01

206

Measurement of the Matrix Element for the Decay $\\eta^{\\prime} \\to \\eta \\pi^+\\pi^-$  

CERN Document Server

The Dalitz plot of $\\eta^{\\prime} \\to \\eta \\pi^+ \\pi^-$ decay is studied using $(225.2\\pm2.8)\\times 10^6$ $\\jpsi$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider. With the largest sample of $\\eta^{\\prime}$ decays to date, the parameters of the Dalitz plot are determined in a generalized and a linear representation. Also the branching fraction of $\\jpsi \\to \\gamma \\eta^{\\prime}$ is determined to be $(4.84\\pm0.03\\pm0.24)\\times 10^{-3}$, where the first error is statistical and the second systematic.

2010-01-01

207

In-beam #gamma#-ray spectroscopy of fast beams at the NSCL  

International Nuclear Information System (INIS)

With the development of an array of highly-segmented germanium detectors, it now becomes possible to perform in-flight #gamma#-ray spectroscopy experiments on intermediate energy beams with unprecedented #gamma#-ray energy resolution. Presented in this report are examples of two techniques in which SeGA, the most highly-segmented operational germanium array for in-flight spectroscopy with fast beams, was used for the detection of #gamma# rays. SeGA used in conjunction with a high-resolution magnetic spectrograph (S800) to detect the reaction residues in coincidence represents a powerful combination for in-beam #gamma#-ray studies.

2004-04-05

208

Electron Beam and Gamma Radiolysis of Solid-State Metoclopramide  

British Library Electronic Table of Contents (United Kingdom)

Purpose Study the radiolysis of solid-state metoclopramide hydrochloride at various absorbed doses. Elucidate the structure of the degradation products to gain information on the radiolysis mechanisms. Methods Solid-state metoclopramide samples were irradiated at several doses with gamma rays and high-energy electrons to evaluate the influence of the dose rate. High-performance liquid chromatography with a diode array detector was used to measure the chemical potency as a function of the absorbed dose and to quantify the degradation products. The characterization of degradation products was performed by liquid chromatography/atmospheric pressure chemical ionization/tandem mass spectrometry. Results The degradation of solid-state metoclopramide after irradiation was negligible. No qualitati...

2006-01-01

209

Development of thin foil Faraday collector as a lost alpha particle diagnostic for high yield D-T tokamak fusion plasmas  

Energy Technology Data Exchange (ETDEWEB)

Alpha particle confinement is necessary for ignition of a D-T tokamak fusion plasma and for first wall protection. Due to high radiation backgrounds and temperatures, scintillators and semiconductor detectors may not be used to study alpha particles which are lost to the first wall during the D-T programs on JET and ITER. An alternative method of charged particle spectrometry capable of operation in these harsh environments, is proposed: it consists of thin foils of electrically isolated conductors with the flux of alpha particles determined by the positive current flowing from the foils. 2 refs., 3 figs.

1994-07-01

210

Determination of Mn, Fe, Cu, Zn, and Pb in particulate matter, raw and final materials of a brick factory by radionuclide X-ray fluorescence analysis  

International Nuclear Information System (INIS)

Radionuclide X-ray fluorescence method with a Si/Li semiconductor detector and "2"3"8Pu exciting source was used in the study of Mn, Fe, Cu, Zn, and Pb content of solid emissions, raw and final materials of a brick factory. From the point of view of metal content, the working environment if the brick factory is safe for workers. (author) 2 refs.; 2 figs.; 1 tab.

1994-01-01

211

Core physics simulation for Wolsung Unit 1 ROP analysis  

International Nuclear Information System (INIS)

It has been issued that ROP(Regional Overpower Protection) for Wolsong Unit 1 needed to be reanalyzed due to the aging effect. Thermo-hydraulics and core simulation have to be performed for calculation of the fuel bundle power, channel power and detector signal production. PPV/MULTICELL/RFSP code system was used to calculate the power distribution for the ROP analysis. In this study, 232 cases out of 926 scenarios which include postulated accidents such as Startup after Short Shutdown, Shim Cases, Stepback, Insertion and Withdrawal of Reactivity Control Rods were simulated.

2001-05-01

212

A new method for sealing containers with liquid samples for radioactivity measurements  

International Nuclear Information System (INIS)

It is imperative to use a leak-proof container for counting liquid sample to prevent contamination of costly gamma detectors. A sealant that ensures no leak is reported. It is a vinyl adhesive sealant used for household purposes, marketed by Gloucester Co., Inc, Franklin, MA under the trade name of Phenoseal (translucent variety). This sealant was superior to other sealants studied because it cures quickly, peels off easily after counting, and contains no detectable radioactivity. This sealant has been thoroughly tested and successfully employed it in the routine analysis of environmental liquid samples. (author)

2002-08-01

213

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector  

CERN Document Server

Design and R&D for the forward calorimeter and silicon tracker of the $\\tau$cF detector

1993-01-01

214

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer  

CERN Document Server

A highly integrated trigger and readout system for a silicon micro-strip detector installed at the CERN Omega spectrometer

1991-01-01

215

Solar energy conversions: solar-electric thermophotovoltaic systems and solar-powered gas lasers  

Energy Technology Data Exchange (ETDEWEB)

This paper deals with conversions of solar energy efficiently into electricity and into gas laser radiation. In the first section, a review study of the possibility of a solar-electric thermophotovoltaic (TPV) device has been done. In a proposed extension of the TPV concept, a Cassagranian optical system concentrates solar radiation to heat a blackbody cavity to 2400/sup 0/K. A double-layer solar cell, GaAs and Si, forming the cylindrical surface concentric to the blackbody cavity, receives the blackbody radiation and converts it into electricity efficiently. A cell conversion efficiency of 50% or more would be possible with the TPV system. The second section explores the concept of blackbody radiation pumping of gas laser media as a step toward utilization of solar energy as a laser pumping source. To demonstrate this concept, an experiment was performed in which various gas mixtures of CO/sub 2/ and He were exposed to 1500/sup 0/K thermal ...

1980-12-01

216

Organometallic vapor phase epitaxial growth of (Al/sub x/Ga/sub 1-x/)/sub 0.5/In/sub 0.5/P and its heterostructures  

International Nuclear Information System (INIS)

The (Al/sub x/Ga/sub 1-x/)/sub 0.5/In/sub 0.5/P material system, lattice matched to GaAs substrates, is useful for visible laser diodes. Here, low pressure organometallic vapor phase epitaxial growth of Ga/sub 0.5/In/sub 0.5/P and (Al/sub x/Ga/sub 1-x/)/sub 0.5/In/sub 0.5/P is examined. Epitaxial layers of bulk materials are characterized using photoluminescence, electroreflectance, Raman scattering spectroscopy, and surface morphology studies to determine lattice match and optimum growth conditions. Lattice matching at the growth temperature produces featureless growth surfaces, while lattice matching at room temperatures results in minimum photoluminescence linewidth but cracked surface due to tensile strain during growth. Raman scattering spectra of the quaternary reveal a three-mode structure, with spectral peaks due to GaP-like, in P-like, and AIP-like LO phonons. Additionally, (Al/sub x/Ga/sub 1-x/)/sub 0.5/In/sub 0.5/P/Ga/sub 0.5/In/sub ...

217

Organometallic vapor phase epitaxial growth of (Al/sub x/Ga/sub 1-x/)/sub 0. 5/In/sub 0. 5/P and its heterostructures  

Science.gov (United States)

The (Al/sub x/Ga/sub 1-x/)/sub 0.5/In/sub 0.5/P material system, lattice matched to GaAs substrates, is useful for visible laser diodes. Here, low pressure organometallic vapor phase epitaxial growth of Ga/sub 0.5/In/sub 0.5/P and (Al/sub x/Ga/sub 1-x/)/sub 0.5/In/sub 0.5/P is examined. Epitaxial layers of bulk materials are characterized using photoluminescence, electroreflectance, Raman scattering spectroscopy, and surface morphology studies to determine lattice match and optimum growth conditions. Lattice matching at the growth temperature produces featureless growth surfaces, while lattice matching at room temperatures results in minimum photoluminescence linewidth but cracked surface due to tensile strain during growth. Raman scattering spectra of the quaternary reveal a three-mode structure, with spectral peaks due to GaP-like, in P-like, and AIP-like LO phonons. Additionally, (Al/sub x/Ga/sub 1-x/)/sub 0.5/In/sub 0.5/P/Ga/sub 0.5/In/sub ...

1988-09-01

218

Materials design for semiconductor spintronics by ab initio electronic-structure calculation  

International Nuclear Information System (INIS)

A systematic study for the materials design of III-V and II-VI compound-based ferromagnetic diluted magnetic semiconductors is given based on ab initio calculations within the local spin density approximation. The electronic structures of 3d-transition-metal-atom-doped GaN and Mn-doped InN, InP, InAs, InSb, GaN, GaP, GaAs, GaSb, AlN, AlP, AlAs and AlSb were calculated by the Korringa-Kohn-Rostoker method combined with the coherent potential approximation. It is found that the ferromagnetic ground states are readily achievable in V-, Cr- or Mn-doped GaN without any additional carrier doping treatments, and that InN is the most promising candidate for high-T_C ferromagnet. A simple explanation of the systematic behavior of the magnetic states in III-V and II-VI compound-based diluted magnetic semiconductors is also given. It is also shown that V or Cr-doped ZnS, ZnSe, and ZnTe are ferromagnetic without p- or n-type doping treatment. However, Mn-, ...

2003-04-01

219

High-temperature ferromagnetism in laser-deposited layers of silicon and germanium doped with manganese or iron impurities  

Energy Technology Data Exchange (ETDEWEB)

The paper reports on the results of a study of the synthesis conditions effects on magnetic and transport properties of nanosized layers of high-T{sub c} diluted magnetic semiconductors (DMS), such as Ge:Mn, Si:Mn and Si:Fe, fabricated by laser-plasma deposition over a wide range of the growth temperature, T{sub g}=(20-550) deg. C on single-crystal GaAs or Al{sub 2}O{sub 3} substrates. Ferromagnetism of the layers was detected by measurement data of the magneto-optical Kerr effect, anomalous Hall effect, negative magnetoresistance and ferromagnetic resonance (FMR) at 5-500 K. The optimum growth temperature, T{sub g}, for Si:Mn/GaAs layers with T{sub c}{approx}400 K is shown to be about 400 deg. C. The Si:Mn/Al{sub 2}O{sub 3} layers with 35% of Mn have the metal-type of conductivity with manifestation of magnetization up to room temperature. Different types of uniformly doped structures and digital alloys have been investigated. In contrast to ...

2009-04-15

220

Electric-field-dependent electroreflectance spectra of visible-band-gap (InAlGa)P quantum-well structures  

Science.gov (United States)

We present results from the first studies of electric-field effects on optical transitions in visible-band-gap InGaP/InAlGaP multiple-quantum-well (MQW) structures. These structures, grown at 775 [degree]C by metalorganic vapor phase epitaxy on (100) GaAs substrates misoriented 6[degree] towards P(111)[r angle][l angle]111[r angle]A, consist of nominally undoped MQWs surrounded by doped In[sub 0.49]Al[sub 0.51]P cladding layers to form [ital p]-[ital i]-[ital n] diodes. The Stark shifts of various allowed and forbidden quantum-well transitions were observed in bias-dependent electroreflectance spectra of In[sub 0.49]Ga[sub 0.51]P/In[sub 0.49](Al[sub 0.5]Ga[sub 0.5])[sub 0.51]P MQW samples with 10-nm-thick layers. We find the magnitude of these shifts to depend on the details of the Mg doping profile, confirming the importance of Mg diffusion and unintentional background doping in these materials. Our results show that (InAlGa)P materials are ...

1994-04-04

221

Electric-field-dependent electroreflectance spectra of visible-band-gap (InAlGa)P quantum-well structures  

International Nuclear Information System (INIS)

We present results from the first studies of electric-field effects on optical transitions in visible-band-gap InGaP/InAlGaP multiple-quantum-well (MQW) structures. These structures, grown at 775 degree C by metalorganic vapor phase epitaxy on (100) GaAs substrates misoriented 6 degree towards P(111)right-angle left-angle 111 right-angle A, consist of nominally undoped MQWs surrounded by doped In_0_._4_9Al_0_._5_1P cladding layers to form p-i-n diodes. The Stark shifts of various allowed and forbidden quantum-well transitions were observed in bias-dependent electroreflectance spectra of In_0_._4_9Ga_0_._5_1P/In_0_._4_9(Al_0_._5Ga_0_._5)_0_._5_1P MQW samples with 10-nm-thick layers. We find the magnitude of these shifts to depend on the details of the Mg doping profile, confirming the importance of Mg diffusion and unintentional background doping in these materials. Our results show that (InAlGa)P materials are promising for visible-wavelength ...

222

A high-sensitivity small animal SPECT system  

International Nuclear Information System (INIS)

Medical imaging using single gamma-ray-emitting radionuclides typically makes use of parallel hole collimators or pinholes in order to achieve good spatial resolution. However, a tradeoff in sensitivity is inherent in the use of a collimator, and modern preclinical single photon emission computed tomography (SPECT) systems detect a very small fraction of emitted gamma rays, often less than 0.1%. A system for small animal SPECT imaging which uses no collimators could potentially achieve very high sensitivity-several tens of percent-with reasonably sized detectors. This would allow two significant improvements in preclinical studies: images could be obtained more rapidly, allowing higher throughput for screening applications, or for dynamic processes to be observed with very good time resolution; and images could be obtained with less radioactive tracer, making possible the in vivo imaging of low-capacity receptor systems, aiding research into ...

2009-03-07

223

Study of some Ayurvedic Indian medicinal plants for the essential trace elemental contents by instrumental neutron activation analysis and atomic absorption spectroscopy techniques  

Energy Technology Data Exchange (ETDEWEB)

Elemental analysis of some medicinal plants used in the Indian Ayurvedic system was performed by employing instrumental neutron activation analysis (INAA) and atomic absorption spectroscopy (AAS) techniques. The samples were irradiated with thermal neutrons in a nuclear reactor and the induced activity was counted by gamma ray spectrometry using an efficiency calibrated high resolution high purity germanium (HPGe) detector. Most of the medicinal plants were found to be rich in one or more of the elements under study. The variation in elemental concentration in same medicinal plants samples collected in summer, winter and rainy seasons was studied and the biological effects of these elements on human beings are discussed. (orig.)

2009-07-01

224

Studies on the separation of Ag(I) during the recovery of Pu by ammonium plutonium(III) oxalate precipitation methodology  

International Nuclear Information System (INIS)

Studies on the separation of Ag(I) during the recovery of Pu from analytical waste generated during potentiometric determination of Pu using AgO as oxidant, by precipitation of Pu as ammonium plutonium (III) oxalate have shown that most of the Ag(I) is separated during the reduction of Pu to Pu(III) state by ascorbic acid. A decontamination factor of 54 was obtained. Additional a decontamination factor of 5.8 was obtained during the precipitation of Pu as ammonium plutonium (III) oxalate. The Ag content was determined by gamma spectrometry, using "1"1"1Ag as a tracer (T_1_/_2 7.45 d, #gamma# 342.1 keV) and HPGe as detector. The studies indicate that Ag is preferentially separated almost quantitatively during the recovery of plutonium, when acidity adjustment is done with NaOH instead of NH_3. (author)

2007-02-14

225

Studies of the low-lying levels in /sup 192/Pt and /sup 192/Os  

Energy Technology Data Exchange (ETDEWEB)

The energy level schemes of /sup 192/Os and /sup 192/Pt have been established on the basis of ..gamma..-..gamma.. coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and ..beta../sup -/ decays of /sup 192/Ir to /sup 192/Os and /sup 192/Pt, respectively. Thirteen new transitions and three new levels at 1146.95, 1237.35 and 1913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, ..cap alpha..(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition.

1985-02-01

226

Studies of the low-lying levels in "1"9"2Pt and "1"9"2Os  

International Nuclear Information System (INIS)

The energy level schemes of "1"9"2Os and "1"9"2Pt have been established on the basis of #gamma#-#gamma# coincidence studies using a dual parameter data collection system. Ge(Li) detectors were employed to study the gamma spectra produced in the E.C. and #beta#"- decays of "1"9"2Ir to "1"9"2Os and "1"9"2Pt, respectively. Thirteen new transitions and three new levels at 1,146.95, 1,237.35 and 1,913.76 keV are suggested. Relative intensities from singles measurements, branching ratios, #alpha#(K) and log ft values were calculated and multipolarities, spins and parities deduced. Comparisons are made with predictions of the Interacting Boson Model calculated on the basis of an O(6) to SU(3) transition. (orig.).

1985-01-01

227

Beam extraction studies at 900 GeV using a channeling crystal  

CERN Document Server

Luminosity-driven channeling extraction has been observed for the first time in a 900 GeV study at the Fermilab Tevatron. This experiment, Fermilab E853, demonstrated that useful TeV level beams can be extracted from a superconducting accelerator during high luminosity collider operations without unduly affecting the background at the collider detectors. Multi-turn extraction was found to increase significantly the efficiency of the process. The beam extraction efficiency was about 25%. Studies of time dependent effects found that the turn-to-turn structure was governed mainly by accelerator beam dynamics. An investigation of a pre-scatterer using the accelerator flying wire system showed that a fiber could produce a significant extracted flux, consistent with expectations. Based on these results, it is feasible to construct a parasitic 5-10 MHz proton beam from the Tevatron collider.

1999-01-01

228

Method and system for determining depth distribution of radiation-emitting material located in a source medium and radiation detector system for use therein  

Energy Technology Data Exchange (ETDEWEB)

A method, system and a radiation detector system for use therein are provided for determining the depth distribution of radiation-emitting material distributed in a source medium, such as a contaminated field, without the need to take samples, such as extensive soil samples, to determine the depth distribution. The system includes a portable detector assembly with an x-ray or gamma-ray detector having a detector axis for detecting the emitted radiation. The radiation may be naturally-emitted by the material, such as gamma-ray-emitting radionuclides, or emitted when the material is struck by other radiation. The assembly also includes a hollow collimator in which the detector is positioned. The collimator causes the emitted radiation to bend toward the detector as rays parallel to the detector axis of the detector. The ...

2003-03-04

229

Time-resolved resonance and linewidth of an ultrafast switched GaAs/AlAs microcavity  

CERN Document Server

We explore a planar GaAs/AlAs photonic microcavity using pump-probe spectroscopy. Free carriers are excited in the GaAs with short pump pulses. The time-resolved reflectivity is spectrally resolved short probe pulses. We show experimentally that the cavity resonance and its width depend on the dynamic refractive index of both the lambda-slab and the lambda/4 GaAs mirrors. We clearly observe a double exponential relaxation of both the the cavity resonance and its width, which is due to the different recombination timescales in the lambda-slab and the mirrors. In particular, the relaxation time due to the GaAs mirrors approaches the photon storage time of the cavity, a regime for which nonlinear effects have been predicted. The strongly non-single exponential behavior of the resonance and the width is in excellent agreement to a transfer-matrix model taking into account two recombination times. The change in width leads to a ...

2009-01-01

230

High-efficiency GaAs solar cells  

Energy Technology Data Exchange (ETDEWEB)

An updated review of the state of the art in the development of GaAs solar cells is provided, with emphasis on AlGaAs-GaAs cells suitable for space applications. A set of theoretically derived characteristics is given for this type of solar cell. Comparison of measured performance with theory shows excellent agreement. Data on the effects of radiation damage (high-energy electrons, protons, and neutrons) is also integrated into a form useful for evaluation purposes. Techniques for fabricating (AlGa)As-GaAs solar cells in quantities large enough for practical applications are discussed and are shown to have been demonstrated. The possibility of extending these techniques to the fabrication of very thin low-weight cells for space applications is also considered. Finally, the results obtained to date in the development of GaAs solar cells for applications requiring concentrated sunlight are reviewed, for terrestrial as well as for space ...

1984-05-01

231

Electrical properties of inalp native oxides for metal-oxide-semiconductor device applications  

Science.gov (United States)

Data are presented on the insulating properties and capacitance-voltage (CV) characteristics of metal-oxide-semiconductor (MOS) device-thickness (below approx. 100 nm) native oxides formed by wet thermal oxidation of thin InAlP epilayers lattice matched to GaAs. Low leakage current densities of J=1.4 x 10-9 A/cm2 and J=8.7 x 10-11 A/cm2 are observed at an applied field of 1 MV/cm for MOS capacitors fabricated with 17 nm and 48 nm oxides, respectively. TEM images show that the In-rich interfacial particles which exist in 110 nm oxides are absent in 17 nm oxide films. Quasi-static capacitance-voltage measurements of MOS capacitors fabricated on both n-type and p-type GaAs show that the InAlP oxide-GaAs interface is sufficiently free of traps to support inversion, indicating an unpinned Fermi level. These data suggest that InAlP native oxides may be a viable insulator for GaAs MOS device applications.

2004-09-01

232

ITER Core Imaging X-Ray Spectrometer Conceptual Design and Performance Assessment - Phase 2  

International Nuclear Information System (INIS)

During Phase 2 of our study of the CIXS conceptual design we have tackled additional important issues that are unique to the ITER environment. These include the thermal control of the crystal and detector enclosures located in an environment with a 100-250 C ambient temperature, tritium containment, and the range of crystal and detector movement based on the need for spectral adjustments and the desire to make measurements of colder plasmas. In addressing these issues we have selected a ''Dewar''-type enclosure for the crystals and detectors. Applying realistic view factors for radiant heat and making allowance for conduction we have made engineering studies of this enclosure and showed that the cooling requirements can be solved and the temperature can be kept sufficiently constant without compromising the specification parameters of the CIXS. We have chosen a minimum 3 mm combined ...

233

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant emittance at 147 nm without implementing vacuum ...

1995-10-01

234

Measurement of $\\phi$(1020) meson leptonic width with CMD-2 detector at VEPP-2M Collider  

CERN Document Server

The $\\phi$(1020) meson leptonic width has been determined from the combined analysis of 4 major decay modes of the resonance ($\\phi\\to K^+ K^-,K^0_LK^0_S,\\pi^+\\pi^-\\pi^0,\\eta\\gamma$) studied with the CMD-2 detector at the VEPP-2M $e^+e^-$ collider. The following value has been obtained: $\\Gamma(\\phi\\to e^+e^-) = 1.235\\pm 0.006\\pm 0.022$ keV. The $\\phi(1020)$ meson parameters in four main decay channels have been also recalculated: $B(\\phi\\to K^+K^-) = 0.493\\pm 0.003\\pm 0.007$, $B(\\phi\\to K_LK_S) = 0.336\\pm 0.002\\pm 0.006$, $B(\\phi\\to\\pi^+\\pi^-\\pi^0) = 0.155\\pm 0.002\\pm 0.005$, $B(\\phi\\to\\eta\\gamma) = 0.0138\\pm 0.0002\\pm 0.0002$.

2010-01-01

235

Improvement of a high-resolution pulse cold neutron spectrometer AGNES  

International Nuclear Information System (INIS)

AGNES is a chopper spectrometer installed at the top of the C3 cold guide of JRR-3 (JAERI, Tokai). In 2004 - 2006, this spectrometer was greatly improved by installing (1) 208 new detectors to make the detector bank complete, (2) new radiation shields composed of Fe (14 mm), polyethylene (50 mm), B4C rubber (10 mm), and Cd (0.5 mm) sheets, (3) a new control system for the anti-frame-overlap chopper rotating simultaneously with the Fermi chopper, (4) a monitor counter at the space between the chopper and monochromator, (5) a neutron guide tube (50 cm) before the monochromator, (6) a new instrument control (monochromators, choppers, beam narrowers, etc.) and measurement control (real-time data monitoring, sample temperature control, etc.) systems, (7) a top-loading type cryostat workable at a wide temperature range of 6 - 480 K. As the results of these improvements, the signal intensity has been increased by 3.3 and the background has been ...

2007-01-01

236

Extreme Ultraviolet Emission from Abell 4059  

CERN Document Server

We present the results of a search for Extreme Ultraviolet emission in A4059, a cluster with an X-ray emitting cluster gas. Our analysis of Extreme Ultraviolet Explorer (EUVE) Deep Survey observations of this cluster shows that it is associated with diffuse EUV emission. Outside the central 2 arcmin radius the entire EUV emission detected is explained by the low energy tail of the X-ray emitting gas. Within the central 2 arcmin region of the cluster we find a deficit of EUV emission compared to that expected from the X-ray gas. This flux deficit is discussed in the context of the cluster's cooling flow. The results derived for A4059 are compared to EUVE results obtained for other clusters such as Coma, Virgo, A1795, and A2199. As part of the study we have carried out a detailed investigation of the stability of the EUVE Deep Survey detector background. Based on long integrations of blank sky over 27 months we disprove claims of substantial time ...

2000-01-01

237

Energy resolution of scintillation detectors readout with large area avalanche photodiodes and photomultipliers  

International Nuclear Information System (INIS)

The energy resolution of small NaI(Tl), CsI(Tl), BGO, GSO, YAP and LSO crystals has been studied using 16 mm diameter large area avalanche photodiodes (LAAPD) and a 52 mm diameter photomultiplier. The best result of 4.8% for 662 keV #gamma#-rays from a "1"3"7Cs source was obtained with a 9 mm in diameter by 9 mm high CsI(Tl) scintillator coupled to an LAAPD. Measuring the number of primary electron-hole pairs produced in the LAAPD and photoelectrons in the photomultiplier, as well as the noise contribution of the LAAPD, allowed a quantitative discussion of the results. The energy resolutions measured with LAAPDs are comparable to, or significantly better (at certain emission wavelengths) than, those obtained with the photomultiplier. At energies above 100 keV the energy resolution measured with the majority of crystals and the LAAPD was weakly affected by the photodiode noise contribution. The advantages and limitations of LAAPDs in energy spectrometry with ...

1998-06-01

238

Determination of the minor disinfection by-products formed in the water plant of Sant Joan Despi (Barcelona, Spain); Determinacion de los subproductos de desinfeccion minoritarios formados en la planta de Sant Joan Despi (Barcelona)  

Energy Technology Data Exchange (ETDEWEB)

Chlorine is widely used in drinking water disinfection due to be a powerful and not expense disinfection. Although the benefits of disinfection, the formation of stable disinfection by-products of the health concern, is the result of the interaction of aqueous chlorine with natural organic matter presents in water. Disinfection by-products generated in major concentration are trihalomethane and haloacetic acids. Disinfection by-products generated in minor concentration are haloacetonitriles, haloketones,chloral hydrate and chloropicrin and some new groups such as cyanogen halides and trihaloacetaldydes. In this work two analytical methods.: headspace/gas chromatography/electron capture detector and liquid-liquid microextraction/gas chromatography/electron capture detector are studied and compared to determine the minor by-products and to establish finally, a systematic control of them in the different stages of the Water ...

1997-09-01

239

Design, construction and testing of a radon experimental chamber; Diseno, construccion y pruebas de una camara experimental de radon  

Energy Technology Data Exchange (ETDEWEB)

To carry out studies on the radon behavior under controlled and stable conditions it was designed and constructed a system that consists of two parts: a container of mineral rich in Uranium and an experimentation chamber with radon united one to the other one by a step valve. The container of uranium mineral approximately contains 800 gr of uranium with a law of 0.28%; the radon gas emanated by the mineral is contained tightly by the container. When the valve opens up the radon gas it spreads to the radon experimental chamber; this contains 3 accesses that allow to install different types of detectors. The versatility of the system is exemplified with two experiments: 1. With the radon experimental chamber and an associated spectroscopic system, the radon and two of its decay products are identified. 2. The design of the system allows to couple the mineral container to other experimental geometries to demonstrate this fact it was coupled and ...

1991-10-15

240

Analysis on Dose Distribution in Heterogeneous Condition for Narrow 6 MV X-ray Beams  

International Nuclear Information System (INIS)

Advanced modality of high-precision radiotherapy fulfilled by a composition of large numbers of small field beams called 'beamlets' can be achieved via nonuniform intensity fluencies. In case of radiation measurements and calculations with narrow high-energy photon beams, however, an accurate two-dimensional dosimetry is a challenging task due to dosimetrically unfavorable phenomena such as dramatic changes of the dose at the field boundaries, dis-equilibrium of the electrons resulting from larger detector volume, and non-uniformity between the detector and the phantom materials. Meanwhile, with the advantages of high spatial resolution and wide range of absorbed doses, there is a growing demand of GAFCHROMICat..EBT film to confirm delivered dose distribution. Especially, the effects from the material differences between the phantom and the film can be minimized in the heterogeneous condition since the GAFCHROMICat..EBT film is composed of ...

2010-10-01

241

Thin film GaAs solar cells on glass substrates by epitaxial liftoff  

Energy Technology Data Exchange (ETDEWEB)

In this work, we describe the fabrication and operating characteristics of GaAs/AlGaAs thin film solar cells processed by the epitaxial liftoff (ELO) technique. This technique allows the transfer of these cells onto glass substrates. The performance of the lifted-off solar cell is demonstrated by means of electrical measurements under both dark and illuminated conditions. We have also optimized the light trapping conditions in this direct-gap material. The results show that good solar absorption is possible in active layers as thin as 0.32 {mu}m. In such a thin solar cell, the open circuit voltage would be enhanced. We believe that the combination of an epitaxial liftoff thin GaAs film, and nano-texturing can lead to record breaking performance. {copyright} {ital 1997 American Institute of Physics.}

1997-02-01

242

Technology of GaAs metal-oxide-semiconductor solar cells  

Science.gov (United States)

The growth of an oxide interfacial layer was recently found to increase the open-circuit voltage (OCV) and efficiency by up to 60 per cent in GaAs metal-semiconductor solar cells. Details of oxidation techniques to provide the necessary oxide thickness and chemical structure and using ozone, water-vapor-saturated oxygen, or oxygen gas discharges are described, as well as apparent crystallographic orientation effects. Preliminary results of the oxide chemistry obtained from X-ray, photoelectron spectroscopy are given. Ratios of arsenic oxide to gallium oxide of unity or less seem to be preferable. Samples with the highest OVC predominantly have As(+3) in the arsenic oxide rather than As(+5). A major difficulty at this time is a reduction in OCV by 100-200 mV when the antireflection coating is vacuum deposited.

1977-01-01

243

Single-event dynamics of high-performance HBTs and GaAs MESFETs  

Energy Technology Data Exchange (ETDEWEB)

Picosecond charge-collection transients measured for GaAs/AlGaAs HBTs following 3.0 MeV [alpha]-particle and 620 nm picosecond laser excitation reveal charge-collection efficiencies up to twenty-eight times smaller than for GaAs MESFETs, with [approximately]90% of the charge collected within 75 ps of the ionizing event. The small charge-collection efficiency of the HBTs is a consequence of the ultrafast charge-collection dynamics in these devices. The authors show that picosecond laser excitation reproduces nicely the ion-induced transients, providing a valuable tool for the investigation of charge-collection and SEU phenomena in these devices.

1993-12-01

244

MOVPE growth of GaAs and InP based compounds in production reactors using TBAs and TBP  

Energy Technology Data Exchange (ETDEWEB)

Today TBP and TBAs are the compounds which have the highest potential to replace the hydrides arsine and phosphine in the MOVPE process. The authors have demonstrated the entire material system Ga-In-As-P can be grown without any loss of quality using TBP and TBAs not only in one reactor, but in a complete family of reactors. These reactors range from small-scale single wafer R and D reactors to multiwafer Planetary Reactor systems. Both InP based and GaAs based materials could be grown with an excellent quality. Thus all growth processes for III-V devices--long and short wavelength lasers, LEDs, high speed transistors, etc.--can be switched to TBP and TBAs. This will drastically reduce safety hazards and lead to processes that have advantages both from the ecological and economical point of view.

1996-12-31

245

Interface-induced conversion of infrared to visible light at semiconductor interfaces  

International Nuclear Information System (INIS)

Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al_xGa_1_-_xInP_2; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. copyright 1996 The American Physical Society.

246

Integrated optoelectronic materials and circuits for optical interconnects  

International Nuclear Information System (INIS)

Conventional interconnect and switching technology is rapidly becoming a critical issue in the realization of systems using high speed silicon and GaAs based technologies. In recent years clock speeds and on-chip density for VLSI/VHSIC technology has made packaging these high speed chips extremely difficult. A strong case can be made for using optical interconnects for on-chip/on-wafer, chip-to-chip and board-to-board high speed communications. GaAs integrated optoelectronic circuits (IOC's) are being developed in a number of laboratories for performing Input/Output functions at all levels. In this paper integrated optoelectronic materials, electronics and optoelectronic devices are presented. IOC's are examined from the standpoint of what it takes to fabricate the devices and what performance can be expected.

247

GaAs pattern etching with little damage by a combination of Ga"+focused-ion-beam irradiation and subsequent Cl_2 gas etching  

International Nuclear Information System (INIS)

Pattern formation on GaAs by Ga"+ focused-ion-beam (FIB) irradiation and subsequent Cl_2 gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl_2 gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga"+ FIB-assisted Cl_2 etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga"+-ion doses.

248

GaAs pattern etching with little damage by a combination of Ga sup + focused-ion-beam irradiation and subsequent Cl sub 2 gas etching  

Energy Technology Data Exchange (ETDEWEB)

Pattern formation on GaAs by Ga{sup +} focused-ion-beam (FIB) irradiation and subsequent Cl{sub 2} gas etching was carried out. A higher etch rate at the FIB-irradiated area compared with that not irradiated under Cl{sub 2} gas allows pattern construction without a mask process. The degree of residual crystal damage was evaluated using photoluminescence (PL) intensity measurements. The PL intensity in the etched region was one order of magnitude stronger than that of FIB sputtering, and was several times stronger than that of Ga{sup +} FIB-assisted Cl{sub 2} etching. Etch depths of the order of 100 nm, which is five times deeper than that obtained by FIB sputtering, were efficiently performed using moderate Ga{sup +}-ion doses.

1990-12-15

249

Characterisation of hole traps in GaAs Fets by DLTS, low frequency noise and g sub M dispersion methods  

International Nuclear Information System (INIS)

Deep level effects in GaAs MOSFET have been characterised in the ohmic channel using DLTS, low frequency excess noise and dispersion technique. An isothermal multi exponential curve fitting method has been devised and implanted into the DLTS system. Multi exponential curve fitting method used to decompose a multi exponential transient into its constituents so that the peak signature can be better characterised for the case whereas several peaks are closely spaced. Low frequency excess noise and dispersion techniques also confirm the trap in signature of the same traps observed in the DLTS measurements. (author)

250

The MiniBooNE detector technical design report  

Energy Technology Data Exchange (ETDEWEB)

The MiniBooNE experiment [1] is motivated by the LSND observation, [2] which has been interpreted as {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, and by the atmospheric neutrino deficit, [3,4,5] which may be ascribed to {nu}{sub {mu}} oscillations into another type of neutrino. MiniBooNE is a single-detector experiment designed to: obtain {approx} 1000 {nu}{sub {mu}} {yields} {nu}{sub e} events if the LSND signal is due to {nu}{sub {mu}} {yields} {nu}{sub e} oscillations, establishing the oscillation signal at the > 5{sigma} level as shown in Fig. 1.1; extend the search for {nu}{sub {mu}} {yields} {nu}{sub e} oscillations significantly beyond what has been studied previously if no signal is observed; search for {nu}{sub {mu}} disappearance to address the atmospheric neutrino deficit with a signal that is a suppression of the rate of {nu}{sub {mu}}C {yields} {mu}N events from the expected 600,000 per year; measure the oscillation ...

2003-04-18

251

Verification of lithium detector efficiency using DD neutron  

International Nuclear Information System (INIS)

The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)

2005-08-01

252

Resonant-mass detectors of gravitational radiation  

International Nuclear Information System (INIS)

A network of second-generation low-temperature gravitational radiation detectors is nearing completion. These detectors, sensitive to mechanical strains of order 10"-"1"8, are possible because of a variety of technical innovations that have been made in cryogenics, low-noise superconducting instrumentation, and vibration isolation techniques. Another five orders of magnitude improvement in energy sensitivity of resonant-mass detectors is possible before the linear amplifier quantum limit is encountered. 33 references, 3 figures, 1 table.

1987-07-01

257

Application of Pd silicide in the process of silicon detectors  

Energy Technology Data Exchange (ETDEWEB)

A new technology called a self-aligned metal-silicide process is described in the fabrication of silicon detectors. It has been found that this technology improves both detector yield and leakage current. The use of a metal silicide also gives a lower contact resistance and, depending on the thermal process, a controllable junction depth, which may be essential in the integration of detectors and their electronics.

1990-04-01

258

ASE FILE  

Science.gov (United States)

radionuclide X-ray fluorescence analysis: the resolving power of the ... The radiation detectors used in radionuclide X-ray fluorescence ...

259

Thin-film UV detectors based on hydrogenated amorphous silicon and its alloys  

Energy Technology Data Exchange (ETDEWEB)

Thin film ultraviolet detectors based on hydrogenated amorphous silicon alloys are realized with different diode structures (PIN, NIP, PN, and NP). The PIN and NIP detectors exhibit higher sensitivity in the ultraviolet spectrum and a significant lower dark current in comparison to the PN or NP structures. The best detector performance was achieved with a 33 nm thick PIN diode. This detector shows a maximum of quantum efficiency of 36.3% at a wavelength of 310 nm. By varying the thickness of the semi-transparent Ag front contact the selectivity of the detectors with the quantum efficiency peak at 320 nm can be adjusted. Thus, the spectral sensitivity of the detector shifts from a broad UV to a selective UV-B spectrum. (orig.)

2001-05-16

260

Influence of Dopants on Characteristics of X-Ray Detectors Fabricated from Indium-, Gallium-, and Chlorine-Doped Cadmium Telluride Single Crystals  

Science.gov (United States)

Counting characteristics of X-ray detectors fabricated from indium-doped, gallium-doped, and chlorine-doped CdTe have been investigated. The detectors fabricated from indium-doped and gallium-doped crystals showed radiation-induced polarization, namely, a progressive decrease of count rate with an increase of photon fluence in the high-photon-fluence region, while the detectors fabricated from chlorine-doped crystals did not. Results from current-voltage characteristics of the detectors indicated that the different counting characteristics of these detectors originated from the difference in internal electric fields in each detector.

1995-08-01

261

Design and fabrication of large ultra-thin PIN detector with membrane stress deviation  

Energy Technology Data Exchange (ETDEWEB)

In this paper, the design of large thin PIN detector with a membrane stress avoidance configuration is proposed, and the related device fabrication process is developed. Ultra-thin PIN detector {approx} 1.13 cm{sup 2} in area is fabricated on a thin ( {approx} 35{mu}m) silicon membrane, and characterized. Detector performance improvement has been successfully demonstrated. With the membrane stress avoidance design, the improved detector exhibits a leakage of 6nA, which is at least 5 times lower than that of detector of identical junction area. The new detector features a full depleted capacitance of 110 pF, and a FWHM of 40.86 keV energy resolution for 5.486 MeV alpha particle spectrography.

2010-09-15

262

Study of the reaction {sup 22}Ne(131 MeV) + {sup 208}Pb with a PIAVE-ALPI test beam and the PRISMA-CLARA set-up  

Energy Technology Data Exchange (ETDEWEB)

An opportunity to study the system {sup 22}Ne+{sup 208}Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The {sup 22}Ne projectiles, having the kinetic energy of 131 MeV, collided with a {sup 208}Pb target 300 {mu}g/cm{sup 2} thick. (The beam was run for {approx}20 hours with a current of {approx}6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, {approx}70 degrees), coupled to the CLARA array of germanium detectors.

2005-07-01

263

Study of "1"0"1Mo decay  

International Nuclear Information System (INIS)

The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. From the coincidence data, the new decay scheme was constructed. The previously reported 104.70, 105.95 and 774.15 keV #gamma# rays were observed, and have been assigned to the decay scheme for the first time. A newly observed 1508.01 keV #gamma# ray has also been assigned to the scheme for the first time. The intensities of #beta#"- and the values of log ft to most levels were calculated

2000-04-01

264

Studies of basic parameters of electron-counting detection  

International Nuclear Information System (INIS)

Measurements have been made of certain parameters relevant to the operation of electron-counting detectors. An experimental chamber consisting of a uniform-field drift tube and a coaxial proportional counter thas been employed to obtain data, at very low drift fields (E/p<0.02 V/cm Torr), on electron mobility and lifetimes in a range of gas mixtures. These mixtures included argon, methane, nitrogen and carbon dioxide. Measurements of single-electron spectra showed that, unexpectedly for the standard gas mixtures employed, useful departure from an exponential spectrum was not possible without the production of cathode secondaries. Although the present studies employed only the counter electrical signal the information obtained should be directly relevant to the operation of practical light-pulse systems. Examples of electron-counting spectra for soft X-rays are shown. (orig.).

1990-05-21

265

Recent results from BESIII  

CERN Document Server

Using about $226\\times 10^6$ $\\jpsi$ events and $106\\times 10^6$ $\\psi^{\\prime}$ events collected with the BESIII detector at the BEPCII $e^+e^-$ collider, the Dalitz plot of $\\etap \\to \\eta \\pi^+ \\pi^-$ decay is studied, the direct measurement of $a^{0}_{0}(980)-f_{0}(980)$ mixing is performed, $X(2120)$ and $X(2370)$ are observed in the $\\pi^+\\pi^-\\eta^\\prime$ invariant mass spectrum, $\\psi^{\\prime}\\to\\gamma\\pi^0$ and $\\psi^{\\prime}\\to\\gamma\\eta$ are observed for the first time, and the decays $\\chi_{cJ}\\to\\gamma V$ ($V=\\phi$, $\\rho^0$, $\\omega$) are studied.

2010-01-01

266

Measurement of cumulative and independent yields of fission products from thermal-neutron fission of /sup 242//sup m/ Am  

Energy Technology Data Exchange (ETDEWEB)

The mass and charge distributions in an unseparated mix of fission product nuclei from thermal-neutron fission of /sup 242m/Am were studied through semiconductor gamma-ray spectrometry. Samples of the fissionable material under study were irradiated in a vertical irradiation tube of the MIFI IRT research reactor. Following irradiation, measurements were made on aperture-calibrated semiconductor detectors. For broader identification of fission fragment nuclides three experiments were conducted that differed substantially in irradiation duration. The spectrum of gamma radiation from the mix of fission products and the time dependences of count rate at total absorption peaks were analyzed on SM-4 and Iskra-226 computers. The values of yields obtained were compared with data of investigations conducted earlier with other experimental methods, and also with the results of calculations.

1985-03-01

267

Development of high resolution imaging detectors for X-ray astronomy  

Energy Technology Data Exchange (ETDEWEB)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-03-01

268

Development of high resolution imaging detectors for X-ray astronomy  

International Nuclear Information System (INIS)

High (spatial) resolution imaging detectors for X-ray astronomy were developed. Several prototype detectors built and their feasibility and baseline performance were assessed. Two of these detector types are proposed for investigations on the advanced X-ray astrophysics facility (AXAF). The readiness of a new X-ray imaging system, the charge coupled device (CCD) imaging specctrometer is outlined, and state of the art performance parameters for microchannel plate (MCP) and CCD detectors are measured. Laboratory facilities and procedures for coating MCP are developed general high resolution imagery systems are analyzed.

1985-01-01

269

Core simulations using actual detector readings for a Canada deuterium uranium reactor  

Science.gov (United States)

This paper reports that, to obtain better simulation results for a Canada deuterium uranium (CANDU) reactor operation, a new simulation method is developed that uses actual detector readings as a correction factor. Detector readings from a CANDU reactor are used to correct the calculated flux distribution during core calculation iterations. A suitable function is found to describe the relationship between the detector flux and the fluxes of mesh points around the detector. The new simulation method is tested by performing numerical calculations for the Wolsung reactor (a CANDU-600). The results show that the new method predicts the core state more accurately with fewer iterations.

1991-02-01

270

Total interaction cross sections and effective atomic numbers of some biologically important compounds containing H, C, N and O in the energy range 6.4-136 keV  

International Nuclear Information System (INIS)

The total interaction cross sections (#sigma#_t) of some sugars and amino acids and five elements: lithium, carbon, oxygen, aluminium and calcium have been measured for 6.4 keV, 13.95 keV, 14.4 keV, 17.74 keV, 24.14 keV, 30.8 keV, 35 keV, 59.54 keV, 81 keV, 122 keV and 136 keV photons in a narrow beam good geometry set up, by using high resolution detectors such as a Si-PIN diode detector and a high purity germanium detector. The #sigma#_t values have been used in a matrix method to evaluate the effective atomic numbers Z_e_f_f of the samples from their effective atomic cross sections #sigma#_a. The effective atomic cross section of a sample #sigma#_a is the total interaction cross section divided by the total number of atoms of all types in it. Further, a quantity called the effective atomic weight A_e_f_f of a sample was defined as the ratio of the molecular weight A to the total number of atoms of all types in it. The ...

2007-09-28

271

The pisa experiment: spallation products identified by bragg curve spectroscopy  

International Nuclear Information System (INIS)

In the framework of spallation neutron sources and accelerator-driven systems, the international PISA (Proton-induced Spallation) collaboration has initiated measurements of total- and double-differential cross-sections for products of spallation reactions in a wide range of target nuclei (GU) at the COSY proton accelerator in Julich (Germany). The purpose is to study secondary particle production created in structural, window and target materials via proton beams up to 2.5 GeV of incident kinetic energy. Residual nuclei [H, He up to intermediate mass fragment (IMF)] production cross-sections are of great importance for estimating the damage to target and structure materials involving the planned spallation neutron sources, given that the lifetime of window and target materials is directly associated to those cross-sections. The demand for reliable theoretical predictions on production cross-sections is by no means satisfied by the models and codes that are ...

2004-05-17

272

Radon generation and transport in and around a gold mine tailings dam in South Africa  

Energy Technology Data Exchange (ETDEWEB)

Naturally Occurring Radioactive Material (N.O.R.M.) occurs in most soil and rock, and by mining and mineral processing, some of the radionuclides are significantly enhanced. An in-situ gamma-ray detector called M.E.D.U.S.A., has been used to produce a map of relative activity concentrations in a gold mine tailings dam on the Witwatersrand in South Africa. A CsI(Na) scintillation detector is used in this system. M.E.D.U.S.A. spectra obtained from the survey were analyzed using the Full-Spectrum Analysis (F.S.A.) procedure to compute the {sup 40}K, {sup 238}U and {sup 232}Th activity concentrations. The activity concentrations are used with global positioning data (G.P.S.) to produce the concentration maps. A hyper-pure germanium gamma-ray detector (Hp Ge) was used to measure gamma-rays from the naturally occurring nuclides for soil samples taken at different points on the site to calibrate the M.E.D.U.S.A. system. Radon soil ...

2006-07-01

273

Performance of SPNDs used in control and safety systems  

International Nuclear Information System (INIS)

Large sized reactor such as 540 MWe Pressurised Heavy Water Reactor (PHWR) requires continuous in core monitoring of local flux in order to provide effective control and protection. About 198 self powered neutron detectors (SPNDs) of the straight individually replaceable type are distributed in the reactor core. For purposes of reactor regulation, 42 prompt responding cobalt SPNDs called zone control detectors (ZCDs) are housed in vertical flux units (VFUs) and these are uniformly distributed in 14 power zones. The in core detectors used for spatial control by ZCCs do not accurately represent average zone power as they sense the flux over a small volume. Flux mapping system (FMS) comprising of 102 vanadium SPNDs in 26 VFUs, provide accurate measure of neutron flux, even though they have slow response to change in neutron flux levels. For reactor protection system-1 (RPS-1), 36 cobalt SPNDs are placed in VFUs and become part ...

2006-11-13

274

Methods and results for calibration and track separation of a GEM based TPC using an UV-laser  

Energy Technology Data Exchange (ETDEWEB)

In the last 30 years high energy physics could write an impressive story of success. Since the introduction of the Standard Model (SM), it has met every experimental test. However the final confirmation has to prove the mechanism of electroweak symmetry breaking, which could not be confirmed yet. The most favored theory, which includes the introduction of a Higgs field, could not be verified experimentally. Furthermore there is clear evidence, that the SM is only a low energy description of nature and its principles, as the SM describes only 4 % of the known matter in the universe. There are two different approaches in accelerator driven high energy physics to clarify the open questions. The Large Hadron Collider (LHC) have a good opportunity to measure some of the missing pieces with its high center of mass energy. The International Linear Collider (ILC) will then measure their parameters with high precision. To guarantee this high precision the detectors have to ...

2008-12-15

275

Radiation damage measurements in room temperature semiconductor radiation detectors  

Energy Technology Data Exchange (ETDEWEB)

The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and increases in FWHM beginning at about 7.5 ...

1998-12-01

276

The polarized electron gun for the SLC  

International Nuclear Information System (INIS)

A new polarized electron gun for use on the SLC at SLAC has been built and tested. It is a diode gun with a laser driven GaAs photocathode. It is designed to provide short (2ns) pulses of 10 A at 160 kV at 120 Hz. The design features of the gun and results from a testing program on a new and dedicated beam line are presented. Early results from operation on the SLC will also be shown.

1992-03-24

277

Solar cells  

Energy Technology Data Exchange (ETDEWEB)

The article is the second part of a review dealing with latest developments in the area of solar cell technologies and application. Physical principles, design and efficiency as well as advantages and disadvantages of GaAs- and CdS-solar cells are described. Power generation solar cell systems with voltage converters, combined solar cell/solar collector systems and thermoelectric solar systems are presented in the second part of the article.

1983-04-01

278

Local Structures and Interface Morphology of InGaAsN Thin Films Grown on GaAs  

Energy Technology Data Exchange (ETDEWEB)

The compound semiconductor system InGaAsN exhibits many intriguing properties which are particularly useful for the development of innovative high efficiency thin film solar cells and long wavelength lasers. The bandgap in these semiconductors can be varied by controlling the content of N and In and the thin films can yet be lattice-matched to GaAs. In the present work, x-ray absorption fine structure (XAFS) and grazing incidence x-ray scattering (GIXS) techniques have been employed to probe the local environment surrounding both N and In atoms as well as the interface morphology of InGaAsN thin films epitaxially grown on GaAs. The soft x-ray XAFS results around nitrogen K-edge reveal that N is in the sp{sup 3} hybridized bonding configuration in InGaAsN and GaAsN, suggesting that N impurities most likely substitute for As sites in these two compounds. The results of In K-edge XAFS suggest a possible trend of a slightly larger coordination ...

1999-02-23

279

Discordant expression and variable numbers of neighboring GGA- and GAA-rich triplet repeats in the 3' untranslated regions of two groups of messenger RNAs encoded by the rat polymeric immunoglobulin receptor gene.  

UK PubMed Central (United Kingdom)

An unusual S1-nuclease sensitive microsatellite (STMS) has been found in the single copy, rat polymeric immunoglobulin receptor gene (PIGR) terminal exon. In Fisher rats, elements within or beyond the...Full Text Available

1995-04-11

280

Comparison of Al{sub 0.51}In{sub 0.49}P and Ga{sub 0.51}In{sub 0.49}P window layers for GaAs and GaInAsP solar cells  

Energy Technology Data Exchange (ETDEWEB)

Two window layer materials, Al{sub 0.51}In{sub 0.49}P (E{sub g} = 2.3 eV) and Ga{sub 0.51}In{sub 0.49}P (E{sub g} = 1.88 eV) were compared for gas-source and solid-source MBE grown GaAs and Ga{sub 0.84}In{sub 0.16}As{sub 0.68}P{sub 0.32} (E{sub g} = 1.55 eV) solar cells. Due to the wider band-gap of Al{sub 0.51}In{sub 0.49}P, the increased spectral response was observed for both GaAs and Ga{sub 0.84}In{sub 0.16}As{sub 0.68}P{sub 0.32} material based solar cells. In the case of the GaAs cells, the short-circuit current density was observed to increase from 32.5 mA/cm{sup 2} to 34.4 mA/cm{sup 2} with the Al{sub 0.51}In{sub 0.49}P window layer at AM0. Similar improvement was observed for the Ga{sub 0.84}In{sub 0.16}As{sub 0.68}P{sub 0.32} solar cells.

1997-12-31

281

The kinematics of coronal mass ejections using multiscale methods  

CERN Document Server

The diffuse morphology and transient nature of coronal mass ejections (CMEs) make them difficult to identify and track using traditional image processing techniques. We apply multiscale methods to enhance the visibility of the faint CME front. This enables an ellipse characterisation to objectively study the changing morphology and kinematics of a sample of events imaged by the Large Angle Spectrometric Coronagraph (LASCO) onboard the Solar and Heliospheric Observatory (SOHO) and the Sun Earth Connection Coronal and Heliospheric Investigation (SECCHI) onboard the Solar Terrestrial Relations Observatory (STEREO). The accuracy of these methods allows us to test the CMEs for non-constant acceleration and expansion. We exploit the multiscale nature of CMEs to extract structure with a multiscale decomposition, akin to a Canny edge detector. Spatio-temporal filtering highlights the CME front as it propagates in time. We apply an ellipse ...

2009-01-01

282

The investigations on K and L X-ray fluorescence parameters of gold compounds  

British Library Electronic Table of Contents (United Kingdom)

The study aimed to determine the chemical effects on the K and L X-ray intensity ratios and the K and L X-ray production cross sections for gold compounds. The K shell fluorescence yields and L shell average yields were also investigated. The samples were excited by 59.5keV ?-rays from an 241Am annular radioactive source and 123.6keV ?-rays from a 57Co annular radioactive source. K and L X-rays emitted from samples were counted by an Ultra-LEGe detector with a resolution of 0.150keV at 5.9keV. The experimental values were compared with theoretical, the semi-empirical and other experimental values.

2010-01-01

283

The application of the neutron time-of-flight technique for real-time diffraction studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

284

The application of the neutron time-of-flight technique for real-time diffraction studies  

International Nuclear Information System (INIS)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

285

The PAMELA space experiment: first year of operation  

Energy Technology Data Exchange (ETDEWEB)

On the 15th of June 2006 the PAMELA experiment, mounted on the Resurs DK1 satellite, was launched from the Baikonur cosmodrome and it has been collecting data since July 2006. PAMELA is a satellite-borne apparatus designed to study charged particles in the cosmic radiation, to investigate the nature of dark matter, measuring the cosmic-ray antiproton and positron spectra over the largest energy range ever achieved, and to search for antinuclei with unprecedented sensitivity. The apparatus comprises a time-of-flight system, a silicon-microstrip magnetic spectrometer, a silicon-tungsten electromagnetic calorimeter, an anticoincidence system, a shower tail catcher scintillator and a neutron detector. The combination of these devices allows charged particle identification over a wide energy range.

2008-05-15

286

Study of J/Psi decays into eta Kstar Kstar-bar  

CERN Document Server

We report the first observation of $\\mPJpsi \\to \\mPeta\\mPKst\\mAPKst$ decay in a $\\mPJpsi$ sample of 58 million events collected with the BESII detector. The branching fraction is determined to be $(1.15 \\pm 0.13 \\pm 0.22)\\times 10^{-3}$. The selected signal event sample is further used to search for the $\\mPY$ resonance through $\\mPJpsi \\to \\mPeta \\mPY, \\mPY\\to\\mPKst\\mAPKst$. No evidence of a signal is seen. An upper limit of \\mathrm{Br}(\\mPJpsi \\to \\mPeta \\mPY)\\cdot\\mathrm{Br}(\\mPY\\to\\mPKst\\mAPKst) < 2.52\\times 10^{-4} is set at the 90% confidence level.

2009-01-01

287

Status of the Daya Bay Reactor Neutrino Oscillation Experiment  

CERN Document Server

The last unknown neutrino mixing angle $\\theta_{13}$ is one of the fundamental parameters of nature; it is also a crucial parameter for determining the sensitivity of future long-baseline experiments aimed to study CP violation in the neutrino sector. Daya Bay is a reactor neutrino oscillation experiment designed to achieve a sensitivity on the value of $sin^2(2\\theta_{13})$ to better than 0.01 at 90% CL. The experiment consists of multiple identical detectors placed underground at different baselines to minimize systematic errors and suppress cosmogenic backgrounds. With the baseline design, the expected anti-neutrino signal at the far site is about 360 events per day and at each of the near sites is about 1500 events per day. An overview and current status of the experiment will be presented.

2011-01-01

288

Short-term radon measurements in the workplace  

Energy Technology Data Exchange (ETDEWEB)

A novel envelope-type radon monitor has been used for short-term (as little as 1 week) radon concentration measurements in a workplace environment. The commercially available LR-115 type II damage track detector was used in this study and the chemically etched sheets were spark counted. The measurements were made over a period of 1 year in a workplace consisting of three adjacent rooms situated in the lower ground level of multistorey office building in Rome, Italy. The variations of the radon concentration are from [approx] 20 to [approx] 300 Bq m[sup -3] with averages of 130,81 and 73 Bq m[sup -3] for the three different rooms resulting in annual doses of [approx] 3.8, [approx] 2.4 and [approx] 2.2 mSv, respectively. (author) 2 figs., 9 refs.

1992-01-01

289

Seasonal variation measurements of radon levels in caves using SSNTD method  

Energy Technology Data Exchange (ETDEWEB)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-15

290

Seasonal variation measurements of radon levels in caves using SSNTD method  

International Nuclear Information System (INIS)

The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm-3, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

2008-08-01

291

Radon concentration measurements in bituminous coal mines  

Energy Technology Data Exchange (ETDEWEB)

Radon measurements were carried out in Kozlu, Karadon and Uzulmez underground coal mines of Zonguldak bituminous coal basin in Turkey. Passive-time integrating method, which is the most widely used technique for the measurement of radon concentration in air, was applied by using nuclear etched track detectors (CR-39) in the study area. The radon concentration measurements were performed on a total of 42 points in those three mines. The annual exposure, the annual effective dose and lifetime fatality risk, which are the important parameters for the health of workers, were estimated based on chronic occupational exposure to the radon gas, which is calculated using UNCEAR-2000 and ICRP-65 models. The radon concentrations at several coal production faces are higher than the action level of 1000 Bq m{sup -3}. It is suggested that the ventilation rates should be rearranged to reduce the radon concentration.

2005-07-01

292

Radon as a tracer of fluids motion in karstic aquifers; Le radon: traceur des circulations fluides dans les aquiferes karstiques  

Energy Technology Data Exchange (ETDEWEB)

Radon ({sup 222}Rn) is a naturally occurring radioactive gas and can be used as a tracer in hydrogeologic studies. Radon concentration measurements have been achieved in ground-air and in groundwater by means of nuclear track detectors to estimate long-term variations. Continuous measurements have been conducted using an electronic automatic probe, to evaluate short-term variations. The results obtained from bore-holes show a good correlation between the aquifer`s structural characteristics and the radon concentrations. The continuous measurements specify rainfall influence. (author). 10 refs., 7 figs., 2 tabs.

1995-04-01

293

Radioactivity in local and imported kaolin types used in Egypt  

Energy Technology Data Exchange (ETDEWEB)

Natural radioactive materials are present in all geological rocks in varying amounts, they are easily mobilized in the environment, and can reach hazardous radiological levels under certain conditions, requiring precautions to be taken. The present study deals with 50 geological samples of local (Tushki and Kalabsha in upper Egypt) and imported (southeast Asia and Turkey) kaolin types. The samples were analyzed by gamma-ray spectroscopy using a HPGe detector. The activity concentrations of {sup 232}Th and {sup 238}U series and {sup 40}K and the contents (in ppm) are given. The radium equivalent activity varied from 187.8 to 10185.19 Bq/kg. {sup 137}Cs was found in a range of 0.23-8.53 Bq/kg, for the local samples. The kaolin in Tushki area was suitable for industrial use.

2004-01-01

294

On Low Energy Levels in 185W  

International Nuclear Information System (INIS)

Gamma ray spectra in the decay of 185Ta and 185mW have been studied with Ge (Li) detectors. The 185mW isomeric transition at 131.6 keV is shown to be of E3 multipolarity. A level scheme of 185W is proposed with the following energy levels (energies in keV, spin and K quantum numbers in brackets): 0 (3/2- 3/2), 23.5 (1/2- 1/2), 65.9 (5/2- 3/2), 93.5 (3/2- 1/2) (uncertain), 173.9 (7/2- 3/2), 188.1 (5/2- 1/2), 197.5 (11/2+ 11/2) , 243.5 (7/2- 7/2), and 390.8 (9/2- 7/2)

1996-03-04

295

Neutron resonances in "1"0"0Mo and valence neutron capture  

International Nuclear Information System (INIS)

Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.

296

Measurements of K-beta/K-alpha X-ray intensity ratios using VEC beams  

International Nuclear Information System (INIS)

An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.

1987-02-03

297

Measurement of dijet cross sections for events with a leading neutron in photoproduction at HERA  

Energy Technology Data Exchange (ETDEWEB)

Differential cross sections for dijet photoproduction in association with a leading neutron using the reaction e{sup +}+p{yields}e{sup +}+n+jet+jet+X{sub r} have been measured with the ZEUS detector at HERA using an integrated luminosity of 6.4 pb{sup -1}. The fraction of dijet events with a leading neutron in the final state was studied as a function of the jet kinematic variables. The cross sections were measured for jet transverse energies E{sub T}{sup jet}>6 GeV, neutron energy E{sub n}>400 GeV, and neutron production angle {theta}{sub n}<0.8 mrad. The data are broadly consistent with factorization of the lepton and hadron vertices and with a simple one-pion-exchange model.

2001-02-26

298

Measurement of charged and neutral current {ital e}{sup {minus}}{ital p} deep inelastic scattering cross sections at high {ital Q}{sup 2}  

Energy Technology Data Exchange (ETDEWEB)

Deep inelastic {ital e}{sup {minus}}{ital p} scattering has been studied in both the charged current (CC) and neutral current (NC) reactions at momentum transfers squared {ital Q}{sup 2} above 400GeV{sup 2} using the ZEUS detector at the HERA {ital ep} collider. The CC and NC total cross sections, the NC to CC cross section ratio, and the differential cross sections {ital d}{sigma}/{ital dQ}{sup 2} are presented. From the {ital Q}{sup 2} dependence of the CC cross section, the mass term in the CC propagator is determined to be {ital M}{sub {ital W}}=76{plus_minus}16{plus_minus}13 GeV.

1995-08-07

299

Levels in sup 152 Gd and sup 152 Sm populated by the decay of sup 152 Eu  

Energy Technology Data Exchange (ETDEWEB)

The energy level schemes of {sup 152}Gd and {sup 152}Sm have been established on the basis of single gamma-spectra, and gamma-gamma coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/beta{sup +} and beta{sup -} decays of {sup 152}Eu to {sup 152}Sm and {sup 152}Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).

1990-01-01

300

Levels in "1"5"2Gd and "1"5"2Sm populated by the decay of "1"5"2Eu  

International Nuclear Information System (INIS)

The energy level schemes of "1"5"2Gd and "1"5"2Sm have been established on the basis of single #gamma#-spectra, and #gamma#-#gamma# coincidence measurements. Ge(Li) detectors were used to study the gamma spectra produced in the EC/#beta#"+ and #beta#"- decays of "1"5"2Eu to "1"5"2Sm and "1"5"2Gd, respectively. Thirteen new transitions are reported and data from eleven coincidence gates enabled five new levels to be suggested. Relative intensities and log ft values were calculated and spin/parities deduced. Comparisons are made with new predictions of the Interacting Boson Model. (orig.).

1990-01-01

301

Identification of fatigue damage in cortical bone by diffraction enhanced imaging  

International Nuclear Information System (INIS)

In an effort to explore Diffraction Enhanced Imaging of bone tissue, experiments were performed to determine if it was possible to use Diffraction Enhanced Imaging to detect microdamage in bovine cortical bone. Measurements were made at the National Synchrotron Light Source where pre- and post-fatigue rocking curve widths of the bone were studied. The rocking curve widths were then compared. Since no consistent pattern of narrowing or broadening of the rocking curve emerged, it is likely that the ultra-small-angle X-ray scattering present in the bone overshadowed any additional changes to rocking curve caused by microdamage of the bone. Larger bone structures were able to be visualized which suggests that microdamage may be visualized with a higher resolution detector.

2005-08-11

302

Effect of different formulations on tebuconazole residues in stone fruits  

British Library Electronic Table of Contents (United Kingdom)

BACKGROUND: The correlation between pesticide residue levels and formulation of an active substance is often not considered, even if it is reasonable to expect some differences arising from behaviour during dilution and spraying, from adhesion to plant and from degradation. An experimental study to investigate the magnitude of tebuconazole residues as a function of different tebuconazole formulated products was carried out in Italy. The fungicide was applied as wettable powder (WP) and water-dispersible granule (WG) formulations to peach, plum, apricot and nectarine orchards, on four different sites. The fruit samples gained from the field trials were quantitatively analysed by gas chromatography with a nitrogen phosphorus detector (GC/NPD) for tebuconazole residues. RESULTS: Tebuconazole ...

2009-01-01

303

Diffusion examined by diffraction  

Science.gov (United States)

X-ray diffraction offers a unique combination of advantages for kinetic study which include the non-destructive nature of the measurement, the use of bulk crystals, and the convenience of the experimental arrangements. These attributes and the availability of position-sensitive detectors and high-flux synchrotron radiation sources make this technique most useful for in situ, dynamical investigations. When using diffraction techniques to determine a diffusion coefficient, the principle of analysis entails a scattering theory and a kinetic model. The former allows the kinetic parameter(s) to be extracted from measured intensity, while the latter relates the kinetic parameter(s) to the diffusion coefficient(s). Three examples are demonstrated: (1) Palladium Silicide (Pd{sub 2}Si) Layer Growth on Silicon, (2) Decomposition of an Ni-12.5at%Si Superalloy, and (3) Short-range Ordering in Cu-Au Solid Solutions.

304

Development of a radon standard source  

Energy Technology Data Exchange (ETDEWEB)

The present paper describes the development of a radon standard source for use in establishing the traceability of radon concentration measurements in air. Previously, radon generated by bubbling air through a radium salt solution was widely used for calibration of radon measurement equipment; however, the handling of a solid-phase radon source is easier. In the present study, the radioactivity of radon released in a vapor phase was determined from the difference between the radioactivity of the radium and the residual radon progenies in the source. A germanium detector, calibrated using gamma reference sources, was used for these radioactivity measurements. Under equilibrium conditions the radioactivity of the radon released from the radium source was found to be 988 Bq. The source was sealed in a stainless-steel container having a nominal capacity of 6 l to produce a radon standard source of density of 167.5 [Bq/l].

2005-06-11

305

Decays of "8"8Kr and "8"8Rb  

International Nuclear Information System (INIS)

The #gamma# rays following the #beta# decays of "8"8Kr and "8"8Rb have been studied, using both large volume Ge(Li) detectors for singles and coincidence measurements and anti-Compton spectrometry for singles measurements. Level schemes for "8"8Rb and "8"8Sr were constructed from the data and 74 of 81 #gamma# rays observed in the decay of "8"8Kr were placed in the "8"8Rb level scheme with 23 excited states. For the decay of "8"8Rb, all of the observed 27 #gamma# rays have been placed in the (well known) level structure of "8"8Sr. Spin and parity assignments have been deduced from #beta#-decay logft values and #gamma#-ray transition patterns. Possible shell model interpretations are presented for the level schemes.

306

Decays of "1"0"1Mo and "1"0"1Tc  

International Nuclear Information System (INIS)

The activities "1"0"1Mo and "1"0"1Tc produced from neutron capture by natural Mo were chemically separated and studied using Ge(Li) #gamma#-ray detectors. Out of 185 transitions observed in the decay of "1"0"1Mo, 170 were assigned to 44 excited levels in "1"0"1Tc. For the decay of "1"0"1Tc, 26 of 27 transitions were placed among 10 excited levels in "1"0"1Ru. The interpretation of the "1"0"1Tc level scheme using the shell-model approach is not satisfactory even for a five-particle calculation. Systematics of odd-A level structures in the region of A=101 indicate that the level structure of "1"0"1Tc could be due partly to the onset of collective effects.

307

Data Management and Mining in Astrophysical Databases  

CERN Document Server

We analyse the issues involved in the management and mining of astrophysical data. The traditional approach to data management in the astrophysical field is not able to keep up with the increasing size of the data gathered by modern detectors. An essential role in the astrophysical research will be assumed by automatic tools for information extraction from large datasets, i.e. data mining techniques, such as clustering and classification algorithms. This asks for an approach to data management based on data warehousing, emphasizing the efficiency and simplicity of data access; efficiency is obtained using multidimensional access methods and simplicity is achieved by properly handling metadata. Clustering and classification techniques, on large datasets, pose additional requirements: computational and memory scalability with respect to the data size, interpretability and objectivity of clustering or classification results. In this study we ...

2003-01-01

308

Crystallization and preliminary X-ray studies of a galactose-specific lectin from the seeds of Spatholobus parviflorus  

British Library Electronic Table of Contents (United Kingdom)

A galactose-specific seed lectin was purified from the legume Spatholobus parviflorus and crystallized using the hanging-drop vapour-diffusion technique. Thecrystals belonged to space group P1, with unit-cell parameters a = 60.998, b=60.792, c = 78.179-, = 101.32, = 91.38, = 104.32. X-ray diffraction data were collected under cryoconditions (100-K) to a resolution of 2.04- using a MAR image-plate detector system mounted on a rotating-anode X-ray (Cu-K) generator. Molecular replacement using legume-lectin coordinates as a search model gave a tetrameric structure.

2011-01-01

309

Coal-liquefaction-process research quarterly report, January 1 - March 31, 1982  

Science.gov (United States)

Objectives of the program are to understand the mechanisms of coal liquefaction, to determine the role of catalysts in the direct conversion of coal to liquids, to determine the mechanism of catalyst deactivation and to explore slurry phase catalyst systems. Specific projects include: short-contact time coal liquefaction, mineral matter effects and catalyst studies. During this period, work was performed on: (1) the stability, at reaction temperature, of a recycle solvent obtained from the Lummus Two Stage Liquefaction facility, (2) reactions of preasphaltenes and asphaltenes prepared under various reaction severities, (3) the evaluation of the catalyst level detector installed at the H-Coal facility, (4) the characterization of oil soluble metal compounds with respect to hydrogenation activity, and (5) characterization, deactivation and regeneration of catalysts obtained from both the H-Coal and Lummus facilities.

1982-10-01

310

Angular dependence from L_3-subshell to M-shell vacancy transfer probabilities for heavy elements using EDXRF technique  

International Nuclear Information System (INIS)

Angular dependence from L_3-subshell to M-shell vacancy transfer probabilities for selected heavy elements from Au to U have been measured by using a Si(Li) detector coupled to a model 1024 computerized multi-channel analyzer. Because the angular dependence from L_3-subshell to M-shell vacancy transfer probabilities is not found in the literature, to the best of our knowledge there are no experimental values for worked elements. Therefore, the results for the elements obtained in the present study constitute the first experimental measurements; the comparison has been not made with other experimental and theoretical results. It has been observed that angular dependence from L_3-subshell to M-shell vacancy transfer probabilities increase with increasing cos #theta#.

2008-07-01

311

An evaluation of the embedment of a Radio Frequency Integrated Circuit with a temperature detector in building envelopes for energy conservation  

British Library Electronic Table of Contents (United Kingdom)

Concrete is the primary material for building envelopes in some parts of the world, and its ability to store heat as well as its dynamic temperature changes will not only affect the deterioration rate of the exterior wall but will also greatly influence the energy efficiency of interior air conditioning. There are many methods for measuring the inner temperature of concrete, but they often have limitations, such as indirect estimation, cable installation requirements, high cost, or heterogeneity of the sample structure. In order to measure the internal temperature of concrete, this study integrated a Radio Frequency Integrated Circuit (RFIC) with a temperature sensor chip and embedded the device in concrete structures. A Smart Temperature Information Material (STIM) was thus developed. Thi...

2011-01-01

312

Study of Z' {yields} e{sup +}e{sup -} in full simulation with regard to discrimination between models beyond the standard model  

Energy Technology Data Exchange (ETDEWEB)

Although experimental results so far agree with predictions of the standard model, it is widely felt to be incomplete. Many prospective theories beyond the standard model predict extra neutral gauge bosons, denoted by Z', which might be light enough to be accessible at the LHC. Observables sensitive to the properties of these extra gauge bosons might be used to discriminate between the different theories beyond the standard model. In the present work several of these observables (total decay width, leptonic cross-section and forward-backward asymmetries) are studied at generation level and with a full simulation in the ATLAS detector. The Z' {yields} e{sup +}e{sup -} decay channel was chosen and 2 values for the mass of Z': 1.5 TeV and 4 TeV. Background is studied as well and it is confirmed that a Z' boson could easily be discovered at the chosen masses. It is shown that even in full ...

2004-09-01

313

High-efficiency, thin-film- and concentrator solar cells from GaAs. Final report; High-efficiency, Duennschicht- und Konzentrator-Solarzellen aus Galliumarsenid. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

Main topic of the project was the manufacturing of highly efficient GaAs-solar cells and the fabrication of concentrator cells. During this process significant progress was made with the material preparation, the solar cell technology and the material and process characterisation. This succeeded in the following efficiencies: - GaAs solar cell made by MOVPE technology: 22.9% on 4 cm{sup 2} (AM1.5g) - GaAs solar cell made by LPE-ER process: 22.8% on 4 cm{sup 2} (AM1.5g) - GaAs concentrator solar cell made by LPE-ER process: 24.9% at C=100xAM1.5d - GaAs concentrator module with fresnel lenses: Module efficiency 20.1% (under irradiation of 793 W/m{sup 2}). Another main focus was the epitaxy of GaAs on Si substrate. Two different approaches were investigated. Together with the cooperation partner ASE, Heilbronn a selective growth technology was developed that led to a decreased crack ...

1996-10-01

314

Focal plane detector for reactions with medium weight projectiles  

Energy Technology Data Exchange (ETDEWEB)

A new focal plane detector for an Enge split pole spectrograph has been developed which is able to resolve individual elements and isotopes up to the mass 100 region. It consists of a 60 cm long position sensitive parallel plate avalanche counter backed by a large Bragg curve detector. Compared with other position sensitive focal plane counters the new detector system has a very good time resolution (less than 300 ps) and can be operated at much higher counting rates (up to 25 kHz). The intrinsic resolution of the position detector is less than 1 mm. In addition to the energy and the nuclear charge signal obtained from the Bragg curve detector the angle of incidence into the detector can be measured with an accuracy of better than 1/sup 0/. The detector has already been used in a variety of experiments where good timing, counting rate ...

1988-12-01

315

Developments of heavy-ion gas detectors at LNL  

Energy Technology Data Exchange (ETDEWEB)

The most important developments in gaseous detectors at LNL are reviewed. Some aspects of timing, pulse height and position resolutions of avalanche counters are reported. The experimental work on heavy-ion identification by Bragg curve spectroscopy is summarized.

1984-05-01

316

Detection of explosives  

Energy Technology Data Exchange (ETDEWEB)

An analyser for detecting explosives has at least one neutron source and a plurality of gamma ray detectors. An article to be analysed is moved adjacent the source and detectors and is subjected to neutrons which generate gamma rays from any nitrogen in the article. The gamma rays are detected and analysed to determine the nitrogen concentration within the article. In order to achieve an area of uniform detection there are a plurality of detectors equidistant both from the or each source and from the article to be analysed. In order to avoid a decrease in sensitivity away from the source(s) and detectors there may be a second opposing array of source(s) and detectors on the opposite side of the article. For greatest uniformity of detection, a source in one array opposes a detector in the other array and vice versa. Transmission of radiation from the analyser is ...

1991-03-13

317

Conventional detectors for a photon-photon collider  

Energy Technology Data Exchange (ETDEWEB)

Detectors for a photon-photon collider are envisaged using as guide-lines the physics goals and the interaction point environment. Production of SUSY Higgs scalar and pseudo-scalar is emphasized. Some aspects of the interaction point environment are discussed. ((orig.)).

1995-02-01

318

Comparison of Detector Intrinsic Spatial Resolution Characteristics for Sensor on the Entrance Surface and Conventional Readout Designs  

UK PubMed Central (United Kingdom)

We report on a high resolution, monolithic crystal PET detector design concept that provides depth of interaction (DOI) positioning within the crystal. Our design utilizes a novel sensor on...Full Text Available

2010-01-01

319

UNFBENJ: on-line, real-time neutron spectrum unfolding for Benjamin detectors  

International Nuclear Information System (INIS)

(Jun 1978). United States Miller, H. Univ. of Missouri, Columbia Peterman,

1978-06-18

320

The virtual fast-ion loss detector  

International Nuclear Information System (INIS)

English 2009 p. 79 Ukraine Brudgam, M. Lauber, Ph. Garcia Munoz, M.

2009-09-21

321

Radionuclide X-ray fluorescence analysis using semiconductor detectors  

International Nuclear Information System (INIS)

Czech May 1979. p. 32-33. Czechoslovakia Benada, J. Spacek, B. Ustav

1979-05-01

322

Parameter optimization of a planar BEGe detector using Monte Carlo simulations  

International Nuclear Information System (INIS)

This work reports on the use of three state-of-the-art Monte Carlo codes (MCNPX, PENELOPE, FLUKA) in the efficiency calibration of a Broad-Energy Germanium (BEGe) detector. Initial discrepancies found between the experimental and computational efficiency values are related to the poor knowledge of some physical parameters of the detector (dead-layers, crystal dimensions, etc.). As a consequence, a sensitivity analysis was carried out. Each parameter was systematically analyzed, and an accurate model of the detector was determined. The obtained results are consistent, allowing this model to be used in computational efficiency calibrations of the equipment at stake.

2010-11-21

323

Method and system for detecting explosives  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2009-03-10

324

Explosives detection system and method  

Energy Technology Data Exchange (ETDEWEB)

A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.

2007-12-11

326

CMS Silicon Strip Tracker Performance  

CERN Document Server

In this paper we describe the reconstruction strategies, the calibration procedures and the detector performance results from the latest CMS operation.

2011-01-01

327

A new technique for radon measurement based on a combination of a track-etch detector and activated charcoal  

Energy Technology Data Exchange (ETDEWEB)

A new technique for radon measurement in the natural environment was investigated. It is based on the use of activated charcoal and a track-etch detector. The charcoal acts as a radon collector from the air and the track-etch detector as a recorder of the alpha particles emitted by radon and its decay products. Our preliminary results show that the response of the new dosimeter to radon, using Deodorant activated charcoal (TOK, Yugoslavia) and a CR-39 track-etch detector, is 1.4 tracks cm{sup -2}/Bqm{sup -3}d, which is about eight times higher than that obtained with a standard track-etch dosimeter. (author).

1991-01-01

328

Using neutron-activation detectors with fissionable nuclides  

Energy Technology Data Exchange (ETDEWEB)

Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.

1986-09-01

329

Test of superconducting Nb/Al bilayers as particle detectors  

Energy Technology Data Exchange (ETDEWEB)

Superconducting thin film particle detectors can be very attractive due to the low sensitivity to radiation damage. We describe the fabrication procedure and the characterization of Nb/Al bilayers as particle detectors. First steady and dynamical results are reported from tests of 5 MeV alpha-particle detection.

2000-04-07

330

Position detector design using an electrostatic application of ANSYS[sup TM  

Energy Technology Data Exchange (ETDEWEB)

The design of beam position monitor (BPM) stripline detectors has been enhanced by using the finite element code ANSYS[sup TM]. Available from Swanson Engineering, ANSYS[sup TM] was developed to solve Poisson's equation in stress and thermal analysis applications. The code is readily adaptable to solving electrostatic problems. The designs of several beam detectors were iterated by calculating electrode capacitances and characteristic impedances to better than 1% accuracy.

1994-10-10

331

Performance of CDF calorimeter simulation for Tevatron Run II  

Energy Technology Data Exchange (ETDEWEB)

The upgraded CDF II detector has collected first data during the initial operation of the Tevatron accelerator in Run II. The simulation of the CDF electromagnetic and hadronic central and upgraded plug (forward) calorimeter is based on the Gflash calorimeter parameterization package used within the GEANT based detector simulation of the Run II CDF detector. We present the results of tuning the central and plug calorimeter response to test beam data.

2002-09-19

332

Neutronic detection device with extended flux range for control of nuclear reactors. Dispositif de detection neutronique a dynamique etendue pour le controle et la commande des reacteurs nucleaires  

Energy Technology Data Exchange (ETDEWEB)

The neutron detector is cased in a metal envelop and has one detector with a very sensitive fission chamber and a second detector with a fission chamber less sensitive that the first one and a boron coated ionisation chamber for reducing gamma radiation detection.

1992-06-12

333

Bragg curve spectroscopy in a 4? geometry  

Science.gov (United States)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4? geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon.

1991-02-01

334

Bragg curve spectroscopy in a 4. pi. geometry  

Energy Technology Data Exchange (ETDEWEB)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4{pi} geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

1991-02-01

335

Bragg curve spectroscopy in a 4#pi# geometry  

International Nuclear Information System (INIS)

Ionization counters employing Bragg curve spectroscopy have been constructed for use in a 4#pi# geometry. These detectors compare very favorably in terms of both energy and charge resolution with small solid angle devices. These detectors have a large dynamic range because they are backed by scintillation detectors, and are thus capable of detecting and identifying particles with energies from 1 MeV/nucleon up to 200 MeV/nucleon. (orig.).

336

A comparison of x-ray detectors for mouse CT imaging  

International Nuclear Information System (INIS)

There is significant interest in using computed tomography (CT) for in vivo imaging applications in mouse models of disease. Most commercially available mouse x-ray CT scanners utilize a charge-coupled device (CCD) detector coupled via fibre optic taper to a phosphor screen. However, there has been little research to determine if this is the optimum detector for the specific task of in vivo mouse imaging. To investigate this issue, we have evaluated four detectors, including an amorphous selenium (a-Se) detector, an amorphous silicon (a-Si) detector with a gadolinium oxysulphide (GOS) screen, a CCD with a 3:1 fibre taper and a GOS screen, and a CCD with a 2:1 fibre taper and both GOS and thallium-doped caesium iodide (CsI:Tl) screens. The detectors were evaluated by measuring the modulation transfer function (MTF), noise power spectrum (NPS), detective quantum ...

2004-12-07

337

Relationships between cosmic ray neutron flux and rain flows  

International Nuclear Information System (INIS)

The registration of secondary cosmic ray neutrons is a convenient tool for the investigation of primary cosmic ray variations and for meteorological effects as well. At present a large network of neutron monitors exists, aiming at studies of cosmic ray variations which are related to interplanetary conditions and geomagnetic activity. At the same time cosmic ray variations may be related to some atmospheric processes. In this connection, using the data from two neutron monitors (a standard and a lead free one), a gamma detector from Moscow station and lead free neutron monitor at BEO Moussala, we studied the correlations between rain flows and neutron flux. In this study we used daily averages on the basis of 10 min data for the neutron flux, corrected for barometric pressure and data from local meteo-stations. The preliminary analysis indicates a correlation between rain flows and neutron flux in ...

2008-09-01

338

Comparison of radon exposure assessment results: {sup 210}Po surface activity on glass objects vs. contemporary air radon concentration  

Energy Technology Data Exchange (ETDEWEB)

Radon exposure assessment in case-control studies on radon and lung cancer is generally based on contemporary radon concentration measurements, which can be affected by significant changes in the building structures or in living habits. Another method to estimate the radon exposure of the subjects is the recently developed retrospective dosimetry technique based on the {sup 210}Po surface activity from glass objects. In order to compare the results obtained by the two methods, a study has been carried out in a sample of 26 dwellings in Rome, with radon concentration values ranging from 28 to 623 Bq m{sup -3}. Retrospective detectors based on CR-39 and LR 115 were exposed on 50 glass objects in bedrooms and living rooms. The correlation factor between the two sets of data, after removing six extreme values, is 0.67, which is similar to results obtained in other validation studies of similar sample size. ...

2003-06-01

339

A variability study of the first catalog of gamma-ray sources on the 2.3 years AGILE data archive  

Science.gov (United States)

AGILE pointed observations performed from July 9, 2007 to October 30, 2009 are a recent, high quality gamma-ray data archive for monitoring studies of medium to high brightness gamma-ray sources in the 30 MeV -50 GeV energy range. We present a variability study of the 1AGL sources over the complete AGILE pointed Observation Blocks (OBs) dataset. The first AGILE Gamma-Ray Imaging Detector (GRID) catalog (Pittori et al. 2009) included a significance-limited (4 sigma) sample of 47 sources (1AGL), detected with a conservative analysis over a first-year non-uniform sky coverage dataset. In this analysis we used data of an improved full Field of View (FOV) event filter, on a much larger (about 27.5 months) observation dataset, analyzing each OB separatedly. This data processing resulted in an improved source list as compared to the 1AGL one. We present here some results on the variability of some of these sources.

2010-01-01

340

A summary of neutron radiography and neutron radioscopy applications at the University of Michigan Phoenix Memorial Laboratory  

International Nuclear Information System (INIS)

Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at Phoenix Memorial Laboratory, the neutron radioscopic imaging systems, the neutron radiographic detectors, lubrication studies, spray imaging, flow in porous media, ...

1992-03-01

341

Determination of radon-222 concentration in inside environments of the Instituto de Engenharia Nuclear, Brazil; Determinacao da concentracao de radonio-222 nos ambientes internos das instalacoes do Instituto de Engenharia Nuclear  

Energy Technology Data Exchange (ETDEWEB)

The gotten concentrations of radon-222 in the installations of the IEN had been determined using the active and passive methods. The active method consisted on the use of the alpha spectrometry with a portable equipment Tracerlab Instruments WLM- Plus. In the determination for the passive method, one used detectors of nuclear strokes of type LEXAN. The raised values had been gotten in the wastes deposit and its annexes, room of the press and laboratory of wastes handling. It was observed, in this sector, an instantaneous measure of alpha spectrometry, concentrations around 1000 Bq.m-3, which had over all to the function of storage, the sector, a great volume of natural radioactive materials, especially of radium-226. This determination was carried through in an extreme situation of ventilation zero, where the gates had been kept closed during the execution of the same one. It was observed, however, a considerable fall, with values ten times inferior, after to ...

2000-07-01

342

Cerenkov ring imaging and spectroscopy of charged KSTAR interactions at 11 GeV/c  

Energy Technology Data Exchange (ETDEWEB)

The physics and technology of this new Cerenkov detector are discussed, including materials studies, construction techniques, and resolution measurements. Sources of resolution error are individually identified and measured where possible. The results of all studied indicate that the measurement resolution is understood. This work has led to the adoption of a large scale ring imaging detector as part of a new high energy physics spectrometer, the SLD, at the Stanford Linear Accelerator Center. Results from an amplitude analysis of strange meson final states in K/sup /minus//p ..-->.. /ovr K/sub 0//..pi../sup /minus//p interactions are presented. The data derive from a 4 event/nb exposure of the LASS (large Aperture Superconducting Solenoid) spectrometer to an 11 GeV/c K/sup /minus// beam. The data sample consists of /approximately/100,000 vents distributed over the Dalitz plot of the channel. The ...

1988-11-01

343

Adaptive Waveform Correlation Detectors for Arrays: Algorithms for Autonomous Calibration  

Energy Technology Data Exchange (ETDEWEB)

Waveform correlation detectors compare a signal template with successive windows of a continuous data stream and report a detection when the correlation coefficient, or some comparable detection statistic, exceeds a specified threshold. Since correlation detectors exploit the fine structure of the full waveform, they are exquisitely sensitive when compared to power (STA/LTA) detectors. The drawback of correlation detectors is that they require complete knowledge of the signal to be detected, which limits such methods to instances of seismicity in which a very similar signal has already been observed by every station used. Such instances include earthquake swarms, aftershock sequences, repeating industrial seismicity, and many other forms of controlled explosions. The reduction in the detection threshold is even greater when the techniques are applied to arrays since stacking can be performed on the ...

2009-07-23

344

Indoor radon concentration measurements in Tarqumia Girl Schools at Western Hebron Region, Palestine  

International Nuclear Information System (INIS)

In this study, radon-222 in indoor air was surveyed in 62 rooms located in four governmental schools, for girls, in Tarqumia town that lies in the north western part of Hebron city in Palestine. The annual effective dose equivalents resulting from the inhalation of radon and its daughters by 2318 pupils and 102 staff members occupying the surveyed rooms were also measured. TASTRAK, a solid state nuclear track detector, has been used to measure the indoor radon concentrations at those schools thus, 124 radon detectors were distributed in the four school buildings. The radon detectors stayed for 70 days between February 2006 and April 2006. The results showed that the radon concentration and the annual effective dose equivalent in these schools were varied from 12 to 232.5 Bq/m"3 with an average of 34.1 Bq/m"3 and 0.62 to 12.0 mSv/y with an average of 1.76 mSv/y, respectively. The mean values of radon ...

345

Position sensitive detection of individual nuclear particle scintillations using image intensifier tubes  

International Nuclear Information System (INIS)

An imaging position sensitive detector for charged particles, neutrons, X-and gamma rays has been developed. The novel feature of this scintillation imaging radiation detector is its ability to detect individual nuclear particle scintillations with a h igh degree of spatial resolution. The key elements of this detector system are a high gain, low noise image intensifier tube, a CCD camera and commercially available image processing hardware and software. This detector system is highly effective for applications such as low fluence and real time neutron radiography, mapping of radioactive contamination in nuclear reactor fuel rods, X-ray diffraction imaging, high speed autoradiography and in general position sensitive detection of nuclear radiation. Results of some of the exploratory experiments carried out using this detector system are presented in this paper. (orig.).

1996-01-01

346

Development and operational experience of traveling in core probe drive for flux scan of 540 MWe PHWR of Tarapur  

International Nuclear Information System (INIS)

TAPP-3 and 4 reactors use large number of Self Powered Neutron Detectors (SPNDs) for Neutronic lower measurement and control. To perform in-situ calibration of these detectors in select locations and to validate the reactor physics codes which predict flux at various points in the core, traveling in-core probes (TIP) are required. The TIP assembly consists of a miniature neutron sensitive detector. The detector is driven in and out of core using a mechanism which facilitates positioning of the detector anywhere inside a vertical tube (Central carrier tube of any of the six select Vertical Flux Units) in the core. TIP is driven through retractable feed mechanism for a stroke of 13 m. This paper describes the developmental efforts and the operational feedback of the retractable feed mechanism for the stroke of 13 m used at TAPP 3 and 4 reactor. (author)

2006-11-13

347

Calibration of solid state nuclear track detector CR-39 for radon measurements  

Energy Technology Data Exchange (ETDEWEB)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

2007-07-01

348

Calibration of solid state nuclear track detector CR-39 for radon measurements  

International Nuclear Information System (INIS)

Solid state nuclear track detectors (SSNTD) are widely used for radon measurements and CR-39 is one of the most popular SSNTD. In this work it was determined the calibration factor for radon concentration measurements through the passive method with CR-39 detectors. The detectors were put in a proper device (an adapted Lucas cell) and exposed to the standard radon concentration through the Pylon Model RN-150 flow through radon gas source. After exposure, the detectors were etched for 5.5 hours in a KOH solution at 80 deg C in a bath at a constant temperature. The track density was read in an Axiolab-Zeiss optical microscope, with nominal magnification of X10 connected to a video camera and to a personal computer. The calibration factor was obtained through the relation between standard radon concentration, track density and exposure time. (author)

349

A new method of imaging particle tracks in solid state nuclear track detectors  

British Library Electronic Table of Contents (United Kingdom)

Summary Solid state nuclear track detectors are used to determine the concentration of a particles in the environment. The standard method for assessing exposed detectors involves 2D image analysis. However 3D imaging has the potential to provide additional information relating to angle as well as to differentiate clustered hit sequences and possibly energy of a particles but this could be time consuming. Here we describe a new method for rapid high-resolution 3D imaging of solid state nuclear track detectors. A `LEXT' OLS3100 confocal laser scanning microscope (Olympus Corporation, Tokyo, Japan) was used in confocal mode to successfully obtain 3D image data on four CR-39 plastic detectors. Three-dimensional visualization and image analysis enabled characterization of track features. This ...

2010-01-01

350

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

1991-09-01

351

A large solid angle, high stopping power Bragg curve spectrometer for coincidence measurements  

International Nuclear Information System (INIS)

A large acceptance, high stopping power, Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. The detector design was aided by the results of computer simulations of the electron collection process in the detector, and of the signal processing in the electronics. The signals from the Bragg curve spectrometer are recorded in a waveform digitizer and the Bragg peak height, range, position and pileup rejection information are determined from software analysis of the recorded signals. Factors limiting the performance of the detector are discussed, and results obtained with ...

352

A Versatile Evaporative Cooling System Designed for Use in an Elementary Particle Detector  

British Library Electronic Table of Contents (United Kingdom)

An evaporative cooling system developed for operation and qualification testing of silicon pixel and microstrip detectors for the inner tracking detector of the CERN ATLAS spectrometer is described. Silicon detector substrates must be continuously operated between 0 and ???7?C in the high radiation environment near the circulating beams at the CERN Large Hadron Collider (LHC). This requirement imposes unusual constraints on the cooling system and has led to the choice of perfluoro-n-propane (C3F8) refrigerant, which combines good chemical stability under ionizing radiation with high dielectric strength and nonflammability. Since the silicon detectors must also be of extremely light construction to minimize undesirable physics background, coolant tubes are of thin (200 ?m) aluminum wall, wh...

2007-01-01

353

A Detector for 2-D Neutron Imaging for the Spallation Neutron Source  

Energy Technology Data Exchange (ETDEWEB)

Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)

2006-07-01

354

The potential of III-V semiconductors as terrestrial photovoltaic devices  

Energy Technology Data Exchange (ETDEWEB)

III-V semiconductors, GaAs and in particular InGaP, are used in many different electronic applications, such as high power and high frequency devices, laser diodes and high brightness LED. Their direct bandgap and high reliability make them ideal candidates for the realisation of high efficiency solar cells: in the past years they have been successfully used as power sources for satellites in space, where they are able to produce electricity from sunlight with an overall efficiency of around 30%. Nowadays, the use of arsenides and phosphides as photovoltaic (PV) devices is confined only to space applications since their price is much higher than conventional Si flat panel modules, the leading PV market technology. But with the introduction of multijunction solar cells capable of operating in high concentration solar light, the area and, therefore, the cost of these cells can be reduced and will eventually find an application and market also on Earth. This article ...

2006-07-01

355

The characteristics of ion-beam-induced spontaneous etching of GaAs by low-energy focused ion beam irradiation  

International Nuclear Information System (INIS)

We have investigated the characteristics of ion-beam-induced spontaneous etching (IBISE) of GaAs in Cl_2 ambient by using a Ga-focused ion beam (FIB) with an energy ranging from 3 to 15 keV. The etched depth of the irradiated region was more than 20 times greater than that of unirradiated region. When the sputtered depth by FIB irradiation amounted to around 8 A at each ion energy, the etched depth in Cl_2 ambient for 1 hour became saturated. The saturated etched depths were 450, 550, 750 and 800 A at the ion energy of 3, 5, 10 and 15 keV, respectively. The residual damage of the etched surface was also investigated by photoluminescence (PL) measurement. The maximal PL intensity was obtained at around the threshold dose of IBISE and increased with decreasing ion energy. The full recovery of PL intensity was observed at the ion energy of 3 keV after annealing at 400degC. (author).

356

Surface Fermi level engineering: Or there's more to Schottky barriers than just making diodes and field effect transistor gates  

Science.gov (United States)

Surface scientists argue about the fundamental nature of Schottky barriers, or more precisely what determines the location of the Fermi level at semiconductor surfaces and interfaces. Electrical and materials engineers worry about how to make Schottky barrier diodes and gates to field effect transistors and the control of barrier heights. There is some interesting middle ground in which the location of the surface and interface Fermi level can, for example, determine semiconductor doping characteristics during crystal growth. The authors will discuss several interesting and well known examples of doping characteristics which are still somewhat mysterious. Specifically, they address the following question: (1) why is Ge doped GaAs p type when grown from Ga melts but n type when grown from Au melts (2) why is low resistivity p type ZnSe, AlAs, and AlGaInP hard to make, and more importantly, how can the problem be fixed. In addition they describe how this concept ...

357

Room-temperature cw operation of InGaP/InGaAlP visible light laser diodes on GaAs substrates grown by metalorganic chemical vapor deposition  

Energy Technology Data Exchange (ETDEWEB)

Room-temperature cw operation for InGaP/InGaAlP double heterostructure (DH) laser diodes on GaAs substrates was achieved for the first time. The DH wafers were grown by low-pressure metalorganic chemical vapor deposition using methyl metalorganics. A lasing wavelength of 679 nm and a threshold current of 109 mA at 24C were obtained for an inner stripe structure laser diode with a 250- m-long and 7- m stripe geometry. The laser operated at up to 51C. The characteristic temperature T0 was 87 K at around room temperature. The lowest threshold current density, 5.0 kA/cmS, was obtained with a 20- m stripe width laser diode under room-temperature pulsed operation.

1986-01-20

358

Positioning of self-assembled InAs quantum dots by focused ion beam implantation  

International Nuclear Information System (INIS)

Self-assembled quantum dots (QDs) are envisioned as building blocks for realization of novel nanoelectronic devices, for which the site-selective growth is highly desirable. This thesis presents a successful route toward selective positioning of self-assembled InAs QDs on patterned GaAs surface by combination of in situ focused ion beam (FIB) implantation and molecular beam epitaxy (MBE) technology. First, a buffer layer of GaAs was grown by MBE before a square array of holes with a pitch of 1-2 #mu#m was fabricated by FIB implantation of Ga and In, ions respectively. Later, an in-situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by FIB. The influence of ion dose, annealing parameters and InAs amount was investigated in this work. With optimized parameters, more than 50 % single dot occupancy per hole is achieved. Furthermore, the photoluminescence spectra from ...

2006-07-01

359

PIXE analysis of GaAs and ZnSe  

Energy Technology Data Exchange (ETDEWEB)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K{sub {alpha}} X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K{sub {alpha}} X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the X-ray intensity ratios are not strongly affected by X-ray absorption; and therefore, the conditions necessary ...

1990-01-01

360

PIXE analysis of GaAs and ZnSe  

International Nuclear Information System (INIS)

The optoelectronic compounds of GaAs and ZnSe are difficult to analyze by PIXE (particle-induced X-ray emission) due to the strong absorption of the As and Se K_#alpha# X-rays. As part of a program to investigate optoelectronic materials using ion beam techniques, we have explored the possibility of using the high sensitivity of PIXE to check these materials for stoichiometry and dopant concentrations. The K_#alpha# X-ray intensity ratios of Ga to As and Zn to Se have been investigated using H beams of 0.5 to 2.5 MeV and He beams of 1.0 to 2.5 MeV. The variation in the X-ray intensity ratio with beam energy and target thickness is modelled in terms of the cross section for X-ray production and the absorption coefficients of the X-rays in the target. The results of this model show the experimental conditions that must be satisfied in order that the X-ray intensity ratios are not strongly affected by X-ray absorption; and therefore, the conditions necessary for ...

1989-06-01

361

MOCVD-grown Al /SUB 0. 5/ In /SUB 0. 5/ P-Ga /SUB 0. 5/ In /SUB 0. 5/ P double heterostructure lasers optically pumped at 90 K  

Energy Technology Data Exchange (ETDEWEB)

Undoped Al /SUB 0.5/ In /SUB 0.5/ P-Ga /SUB 0.5/ In /SUB 0.5/ P double heterostructure was grown on (100) GaAs by metalorganic chemical-vapor deposition for the first time. A mirror-like grown surface was obtained. Over ten-times stronger photoluminescence-intensity was gained from the sandwiched Ga /SUB 0.5/ In /SUB 0.5/ P-layer, than that from a single epitaxially-grown Ga /SUB 0.5/ In /SUB 0.5/ P-layer on (100) GaAs, indicating that high-quality Al /SUB 0.5/ In /SUB 0.5/ P-Ga /SUB 0.5/ In /SUB 0.5/ P heterointerfaces are formed in the double heterostructure. A lasing action by optical pumping with an argon ion laser was observed in the double heterostructure at 90 K. The observed stimulated emission wavelength was 6470 A.

1982-12-01

362

Interface-induced conversion of infrared to visible light at semiconductor interfaces  

Science.gov (United States)

Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al{sub {ital x}}Ga{sub 1{minus}{ital x}}InP{sub 2}; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. {copyright} {ital 1996 The American Physical Society.}

1996-08-01

363

Generation of ammonia plasma using a helical antenna and nitridation of GaAs surface  

International Nuclear Information System (INIS)

Using the ammonia (NH3) plasma generated by a helical antenna surrounded by two magnetic coils, the transition of the discharge mode from low-density plasma to high-density one was observed. At the transition, the emission intensities from the H atoms and NH radicals especially increased in the optical emission spectroscopy, while the intensities of the other emission lines also increased abruptly. The nitridation of gallium arsenide (GaAs) surface was performed using the high-density NH3 plasma, and the properties of the nitrided surface layer were compared with those nitrided by high-density N2 plasma using the same apparatus. From the spectroscopic ellipsometry measurements, the thickness of the nitrided layer was estimated to be 16-18 nm, while that by N2 was 3-4 nm. From the Ga 3d spectra, the contamination with oxygen in the nitridation layer by NH3 plasma was less than that by N2 plasma.

2003-05-15

364

Exploring the 2D to 3D dimensionality crossover in thin iron films  

Energy Technology Data Exchange (ETDEWEB)

The temperature dependence of the spontaneous magnetization of epitaxial iron films with a thickness ranging from d=20 to 200nm has been measured. The films are grown on GaAs (100) substrates which are covered by a 150nm thick silver (100) buffer layer. For three-dimensional BCC iron it was observed already in 1929 that saturation of the spontaneous magnetization for T->0 is perfectly described by a T{sup 2} power law. On the other hand, for thin two-dimensional (2D) iron films a T{sup 3/2} law has been established in many recent experimental investigations. In our iron films grown on diamagnetic silver, this dimensionality change occurs at a thickness between d=100 and 200nm. Comparison of the here-observed T{sup 3/2} coefficients with those on iron films grown on paramagnetic tungsten (110) shows that the 2D interactions are {approx}20 times larger in the films on tungsten. Recent results on Fe films which are grown directly on GaAs ...

2006-05-15

365

Al[sub 0. 3]Ga[sub 0. 7]As/GaAs heterojunction tunnel diode for tandem solar cell applications  

Energy Technology Data Exchange (ETDEWEB)

A p[sup +]-Al[sub 0.3]Ga[sub 0.7]As/n[sup +]-GaAs heterojunction tunnel diode was fabricated using Atomic Layer Epitaxy (ALE) growth technique. Background carbon doping of [similar to]10[sup 20] cm[sup [minus]3] was achieved in the p-side of the diode by optimizing growth conditions such as V/III ratio, exposure times to reactant gases, and growth temperature. In the n-side of the diode GaAs was doped with silane and doping concentrations as high as 7[times]10[sup 18] cm[sup [minus]3] were also achieved. The dopants are chosen to satisfy the high levels and low diffusion requirements. The diode can be used to interconnect the high and low band-gap cells in the AlGaAs/GaAs cascade solar cell structure. The reactor used in this investigation is a commercial MOCVD system which has been specially modified for dual operation of ALE and MOCVD growth modes.

1994-06-30

366

Introducing DeBRa: a detailed breast model for radiological studies  

Energy Technology Data Exchange (ETDEWEB)

Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The ...

2009-07-21

367

Using focused ion beam damage patterns to photoelectrochemically etch features in III-V materials  

Energy Technology Data Exchange (ETDEWEB)

A method of patterning n-type GaAs, InP, InGaAs, and InGaAsP by photoelectrochemical (PEC) etching in conjunction with a submicron focused ion beam (FIB) at low dose is described. The ion beam is used to produce damage in a desired pattern in the material. Subsequent PEC etching of the material reveals the ion induced features in relief. The procedure is highly sensitive, requiring a dose of only 5 x 10/sup 9/ ions/cm/sup 2/ for the differential etch to become apparent. The sensitivity allows rapid pattern generation in our FIB system.

1986-03-10

368

State-of-the-art in photovoltaic research and application (except for use in concentrators)  

Energy Technology Data Exchange (ETDEWEB)

A review is given of the state-of-the-art of single and polycrystalline solar cells, which includes a short theoretical review, laboratory achievements, and production methods. The Si single and polycrystalline cell and the amorphous Si cell are described, including material preparation, crystal and sheet growth, and cell and panel production. Promising second generation thin film solar cells including GaAs, CdS(CuInSe/sub 2/), and CdTe are briefly described. Economical aspects are discussed.

1987-01-01

369

Microcomputers: usage, methods and structures  

International Nuclear Information System (INIS)

The use of workstations, controllers or embedded systems and their applications have become much more relevant than previously. PC-based systems, a cooker programmer, applications of, for example, Prolog machines, Unix and Ada papers, Robotics and Automation are typical examples of this. The three keynote addresses of this symposium have as their subjects the most spectacular microcomputer fields and are presented by leading experts. The papers presented cover most of the traditional interests of Euromicro. Special emphasis is given to contributions on the use of workstations and personal computers, on RISC and GaAs and on transputers.

370

Local Heine-Abarenkov model potential for III-V and II-VI covalent compounds  

Energy Technology Data Exchange (ETDEWEB)

A local Heine-Abarenkov model potential is proposed for zinc blende-type crystals. The potential parameters are determined by satisfying the zero pressure condition and the first zero of the empirical pseudopotential interpolated from band calculations. Two sets of parameters are presented for thirteen tetrahedral compounds such as AlP, AlAs, AlSb, GaP, GaAs, GaSb, InP, InAs, InSb, ZnS, ZnSe, ZnTe, and CdTe.

1983-10-01

371

CuPt-type ordering of MOCVD In{sub 0.49}Al{sub 0.51}P.  

Science.gov (United States)

CuPt-type ordering in In{sub 0.49}Al{sub 0.51}P is studied by TEM. The lattice-matched film was grown by MOCVD on a GaAs substrate oriented 10{sup o} off (001) towards [110], at 650 C and 25 nm/min. TEM [110] and [1{bar 1}0] cross-sections (XS) were made by wedge polishing and 2 kV Ar ion milling. In CuPt-type ordering of In{sub 0.52}Ga{sub 0.48}P, alternating In-Ga-In-Ga {l_brace}111{r_brace} planes of group III atoms produce 1/2 {bar 1}11 and 1/2 1{bar 1}1 order spots in the 110 SADP, while the [1{bar 1}0] SADP shows no order spots [1-3]. A few studies have reported this type of order in In{sub 0.49}Al{sub 0.51}P [4]. The 004 BF image of the [1{bar 1}0] XS in Fig. 1 shows uneven light/dark contrast modulation due to phase separation often observed in In{sub 0.52}Ga{sub 0.48}P. There are also light/dark layers marked ML parallel to the film growth plane; such unintentional multilayers have also been observed [5] but their ...

2002-03-14

372

Neutron detector counting capabilities for /sup 10/B-lined and /sup 235/U fission chambers in high gamma-ray fluxes  

Energy Technology Data Exchange (ETDEWEB)

This report compares the performance characteristics of /sup 10/B-lined and fission-neutron detectors in gamma-ray fluxes typical of the fields to be encountered during nondestructive testing of irradiated light-water fuel assemblies stored in water. Using the optimum time constants for each of the /sup 10/B-lined detectors, the 0.25-in.-dia detector had a 5% loss in neutron count sensitivity at 7000 rad/h. Similarly, the 0.5-in.-dia detector had a 7% loss at 13,000 rad/h and the 1-in.-dia detector had a 5% loss in sensitivity at 1000 rad/h. Uranium-235 fission chambers were operated successfully in fields above 100,000 rad/h with no loss in neutron counting sensitivity. Shielding calculations were done to determine the appropriate shield thickness needed for a /sup 10/B-lined neutron detector to operate in a 50,000 rad/h field, typical of light-water-reactor ...

1985-03-01

373

Large area, low capacitance Si(Li) detectors for high rate x-ray applications  

Energy Technology Data Exchange (ETDEWEB)

Large area, single-element Si(Li) detectors have been fabricated using a novel geometry which yields detectors with reduced capacitance and hence reduced noise at short amplifier pulse-processing times. A typical device employing the new geometry with a thickness of 6 mm and an active area of 175 mm 2 has a capacitance of only 0.5 pf, compared to 2.9 pf for a conventional planar device with equivalent dimensions. These new low capacitance detectors, used in conjunction with low capacitance field effect transistors, will result in x-ray spectrometers capable of operating at very high count rates while still maintaining excellent energy resolution. The spectral response of the low capacitance detectors to a wide range of x-ray energies at 80 K is comparable to typical state-of-the-art conventional Si(Li) devices. In addition to their low capacitance, the new devices offer other advantages over ...

1992-10-01

374

Yields of short-lived fission products produced following "2"3"5U(n_t_h,f)  

International Nuclear Information System (INIS)

Measurements of gamma-ray spectra, following the thermal neutron fission of "2"3"5U have been made using a high purity germanium detector at the University of Massachusetts Lowell (UML) Van de Graaff facility. The gamma spectra were measured at delay times ranging from 0.2 s to nearly 10000 s following the rapid transfer of the fission fragments with a helium-jet system. On the basis of the known gamma transitions, forty isotopes have been identified and studied. By measuring the relative intensities of these transitions, the relative yields of the various precursor nuclides have been calculated. The results are compared with the recommended values listed in the ENDF/B-VI fission product data base (for the lifetimes and the relative yields) and those published in the Nuclear Data Sheets (for the beta branching ratios). This information is particularly useful for the cases of short-lived fission products with lifetimes of the order of fractions ...

1998-08-01

375

Untersuchung von Bildqualitat und Genauigkeit der Dosisberechnung bei cone-beam-CT-Aufnahmen mit reduziertem Projektionsdatensatz (half scan, half fan) im Hinblick auf die Verwendbarkeit fur die adaptive Bestrahlungsplanung  

British Library Electronic Table of Contents (United Kingdom)

Subject of this study is the question of whether cone beam CT (CBCT) images with reduced projection data are suitable for use in adaptive radiation therapy (ART) treatment planning. For this purpose image quality and dose calculation accuracy depending on imaging modality were analysed. In this context, two CBCT-methods will be indicated having reduced projection data sets: Scans acquired with 200^o rotation angle in order to accelerate the CBCT process (half scan), or scans with an asymmetric cone beam and detector offset, used to enlarge the field-of-view (half fan). Methods: For three different CBCT-modes (On-Board-Imaging, Varian Medical Systems), two of them based on reduced projection data, and a conventional multidetector CT system, the main image quality parameters were studied. Tr...

2011-01-01

376

The study of "1"0"1Mo decay  

International Nuclear Information System (INIS)

The decay of "1"0"1Mo to levels in "1"0"1Tc has been studied using the three-parameter (#gamma#-#gamma#-t) coincidence system of HpGe-HpGe detectors. According to the coincidence data, the decay scheme was modified. The positions of 221.80, 318.00, 377.90, 452.50, 515.42, 1011.05 and 1759.72 keV transitions have been arranged again, the transition positions of 104.70, 105.95 and 774.15 keV gamma-rays have been assigned for the first time, the positions of 169.00, 590.91, 980.52 and 1431.68 keV transitions have been reconfirmed, the 1508.01 keV gamma-ray was observed simultaneously for the first time and its transition position has been assigned. The #beta#-intensities and the values of log ft of most levels were calculated. (author)

2000-09-01

377

The Cross-Calibration of Swift-BAT and Fermi-GBM via Correlative Spectral Analysis of GRBs  

CERN Document Server

We report on recent inter-calibration studies featuring Swift's Burst Alert Telescope (BAT) and Fermi's Gamma-ray Burst Monitor (GBM) based upon correlated observations of GRBs 080804 and 080810, via their resultant joint spectral analysis. Swift's intrinsic multi-wavelength instrumentation and dynamical response complement Fermi's superior energy range. The addition of BAT's spectral response will (i) facilitate in-orbit GBM detector response calibration, (ii) augment Fermi's low energy sensitivity, (iii) enable ground-based follow-up efforts of Fermi GRBs, and (iv) help identify a subset of GRBs discovered via off-line GBM data analysis, for an annual estimate of ~30 GRBs. The synergy of BAT and GBM augments previous successful joint spectral fit efforts by enabling the study of peak photon energies (Epeak), while leveraging the over eleven energy decades afforded by Fermi's Large Area Telescope (LAT), in conjunction with ...

2009-01-01

378

Study of the Photon Strength Functions for Gadolinium Isotopes with the DANCE Array  

Science.gov (United States)

The gadolinium isotopes are interesting for reactor applications as well as for medicine and astrophysics. The gadolinium isotopes have some of the largest neutron capture cross sections. As a consequence they are used in the control rod in reactor fuel assembly. From the basic science point of view, there are seven stable isotopes of gadolinium with varying degrees of deformation. Therefore they provide a good testing ground for the study of deformation dependent structure such as the scissors mode. Decay gamma rays following neutron capture on Gd isotopes are detected by the DANCE array, which is located at flight path 14 at the Lujan Neutron Scattering Center at Los Alamos National Laboratory. The high segmentation and close packing of the detector array enable gamma-ray multiplicity measurements. The calorimetric properties of the DANCE array coupled with the neutron time-of-flight technique enables one to gate on a specific resonance of a ...

2009-03-10

379

Study of metal concentration in sediment of some springs of Lebanon  

International Nuclear Information System (INIS)

Full text.Surficial sediment samples were collected from seventeen springs distributed all over Lebanon (east, west, north and south). Concentrations of metals Ca, Fe, Mn, Ni, Cu, Cr, Zn and Pb were determined by energy dispersive x-ray fluorescence technique. Irradiation was done by the radioisotope source Cd-109 and the detection by an EG and G Si(Li) detector. These analysis was done in attempt to assess the impact of anthropogenic sources on ground water quality. Metals concentration in sediment were found to be (Ca:0.05-47%, Fe:0.24-4.2%, Cr:study were of the same order of magnitude as those obtained from other regions of ...

1999-11-02

380

Study of e{sup +}e{sup -}{yields}pp using initial state radiation with BABAR  

Science.gov (United States)

The e{sup +}e{sup -}{yields}pp cross section is determined over a range of pp masses, from threshold to 4.5 GeV/c{sup 2}, by studying the e{sup +}e{sup -}{yields}pp{gamma} process. The data set corresponds to an integrated luminosity of 232 fb{sup -1}, collected with the BABAR detector at the PEP-II storage ring, at an e{sup +}e{sup -} center-of-mass energy of 10.6 GeV. The mass dependence of the ratio of electric and magnetic form factors, G{sub E}/G{sub M}, is measured for pp masses below 3 GeV/c{sup 2}; its value is found to be significantly larger than 1 for masses up to 2.2 GeV/c{sup 2}. We also measure J/{psi}{yields}pp and {psi}(2S){yields}pp branching fractions and set an upper limit on Y(4260){yields}pp production and decay.

2006-01-01

381

Study of building materials impregnation processes by quasi-real-time neutron radiography  

International Nuclear Information System (INIS)

Neutron radiography (NR) is a useful non-destructive method for determination of hydrogen content in various building and technical materials. Monitoring of transport processes of moisture and hydrogenous liquids in porous building materials is enabled by fast, quasi-real-time NR methods based on novel imaging plate neutron detectors (IP-NDs). Hydrogen content in the samples is determined by quantitative analysis of measured profiles of neutron attenuation in the samples. Detailed description of quantitative NR method is presented by the authors in another accompanying contribution at this conference. Deterioration of building materials is originated by different processes that all require presence of water therefore it is essential to limit or prevent the transport of water through the porous material. In this presentation, results of a study of clay brick impregnation by silicone based hydrophobic agents will be presented. Quantitative ...

1999-11-03

382

Search for supersymmetric partner of bottom quark at d0 at Tevatron. Studies on missing transverse energy  

Energy Technology Data Exchange (ETDEWEB)

Supersymmetry, extension of the Standard Model of Particle Physics (SM), is searched for by trying to observe the supersymmetric partner of bottom quark ({tilde b}). This search is performed using events with a final state comprising two acoplanar b-quark jets and missing transverse energy (MET) and coming from a sample of 992 pb{sup -1} of data collected by the D0 detector at the Tevatron, the Fermilab p{bar p} collider. The absence of an excess of events in comparison to MS expectations leads to exclude sb masses up to 201 GeV, neutralino masses up to 94 GeV. The MET has been studied under two points of view, because of its fundamental role in this search. First, at the level of the trigger system which allows the online selection candidate events, and then, within the framework of the ALPGEN generator, the simulation of the Z boson transverse momentum which appears as MET when the Z boson decays into neutrino.

2007-09-01

383

Radon concentration measurements in the desert caves of Saudi Arabia  

Energy Technology Data Exchange (ETDEWEB)

Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm{sup -3}. The average radon concentration in four of the caves was low in the range 74-114Bqm{sup -3}. However, one cave showed an average radon concentration of 451Bqm{sup -3}. Radon ...

2005-11-15

384

Radon concentration measurements in the desert caves of Saudi Arabia  

International Nuclear Information System (INIS)

Beneath the harsh deserts of Saudi Arabia lie dark chambers and complex mazes filled with strange shapes and wondrous beauty. Radon concentration measurements have been carried out in the desert caves of Al-Somman Plateau in the Eastern Province of Saudi Arabia. Passive radon dosimeters, based on alpha particle etch track detectors with an inlet filter, were used in this study. A total of 59 dosimeters were placed in five caves for a period of six months. Out of 59 dosimeters, 37 could be collected for analysis. Measurements showed significant variations in radon concentrations in caves depending upon their natural ventilation. The results of the study show that the average radon concentration in the different caves ranges from 74 up to 451Bqm"-"3. The average radon concentration in four of the caves was low in the range 74-114Bqm"-"3. However, one cave showed an average radon concentration of 451Bqm"-"3. Radon is not a ...

2005-11-01

385

Radiometric analysis of raw materials and end products in the Turkish ceramics industry  

International Nuclear Information System (INIS)

This study presents the findings of radiometric analysis carried out to determine the activity concentrations of natural radionuclides in raw materials (clay, kaolin, quartz, feldspar, dolomite, alumina, bauxite, zirconium minerals, red mud and frit) and end products (glazed ceramic wall and floor tiles) in the Turkish ceramics industry. Hundred forty-six samples were obtained from various manufacturers and suppliers throughout the country and analyzed using gamma-ray spectrometer with HPGe detectors. Radiological parameters such as radium equivalent activity, activity concentration index and alpha index were calculated to assess the radiological aspects of the use of the ceramic end products as decorative or covering materials in construction sector. Results obtained were examined in the light of the relevant national and international legislation and guidance and compared with the results of similar studies reported in ...

2011-05-01

386

PDE-based Non-Linear Diffusion Techniques for Denoising Scientific and Industrial Images: An Empirical Study  

Energy Technology Data Exchange (ETDEWEB)

Removing noise from data is often the first step in data analysis. Denoising techniques should not only reduce the noise, but do so without blurring or changing the location of the edges. Many approaches have been proposed to accomplish this; in this paper, they focus on one such approach, namely the use of non-linear diffusion operators. This approach has been studied extensively from a theoretical viewpoint ever since the 1987 work of Perona and Malik showed that non-linear filters outperformed the more traditional linear Canny edge detector. They complement this theoretical work by investigating the performance of several isotropic diffusion operators on test images from scientific domains. They explore the effects of various parameters such as the choice of diffusivity function, explicit and implicit methods for the discretization of the PDE, and approaches for the spatial discretization of the non-linear operator etc. They also compare ...

2001-12-20

387

Non-thermal atmospheric pressure HF plasma source: generation of nitric oxide and ozone for bio-medical applications  

International Nuclear Information System (INIS)

A new miniature high-frequency (HF) plasma source intended for bio-medical applications is studied using nitrogen/oxygen mixture at atmospheric pressure. This plasma source can be used as an element of a plasma source array for applications in dermatology and surgery. Nitric oxide and ozone which are produced in this plasma source are well-known agents for proliferation of the cells, inhalation therapy for newborn infants, disinfection of wounds and blood ozonation. Using optical emission spectroscopy, microphotography and numerical simulation, the gas temperature in the active plasma region and plasma parameters (electron density and electron distribution function) are determined for varied nitrogen/oxygen flows. The influence of the gas flows on the plasma conditions is studied. Ozone and nitric oxide concentrations in the effluent of the plasma source are measured using absorption spectroscopy and electro-chemical ...

2010-01-01

388

Effect of Infrared Pulsated Laser on the Dielectric Properties of Makrofol Polycarbonate  

International Nuclear Information System (INIS)

Makrofol-De 1-1 CC Polycarbonate is a class of polymeric solid state nuclear track detectors which has many applications in various industrial fields. A study of the modification possibility of the dielectric properties of Makrofol polymer using laser irradiation has been carried out. In tbe present work, Makrofol samples were irradiated using different fluences between 0.47 and 10.4 J/cm"2 of 5 watt infrared pulsated laser. The mollifications in the laser irradiated Makrofol samples have been studied as a function of fluence using dielectric constant #epsilon#', dielectric loss #epsilon#"and AC conductivity #sigma#_AC measurements. Tbe frequency dependencies (100 Hz-5 MHz) of #epsilon#', #epsilon#"and #sigma#_AC at 35 degree c were investigated. The dielectric constant #epsilon#', dielectric loss #epsilon#"and AC conductivity #sigma#_AC were found to increase at heating up to 100 degree C. This indicates that #epsilon#', ...

389

Determination of the radon diffusion coefficient and radon exhalation rate in Moroccan quaternary samples using the SSNTD technique  

International Nuclear Information System (INIS)

Measurements have been made of radon ("2"2"2Rn), release from diverse quaternary samples collected from different sediment deposits in the Errachidia and Beni-Mellal areas (Morocco). The radon diffusion coefficient as one of some important parameters of radon transport in the soil has been measured using solid state nuclear track detectors (SSNTD). Radon #alpha#-activity, uranium content and radon exhalation rate have been determined in the studied samples. Uranium concentrations were found to vary from 0.14 to 9.52 ppm whereas the radon exhalation rate varied from 0.003 to 0.145 Bq x m"-"2 x h"-"1. A positive correlation has been found between radon exhalation rate and uranium content in the studied samples. The average radon diffusion coefficients were found to vary from (1.26 #+-# 0.09) x 10"-"6 m"2 x s"-"1 to (4.3 #+-# 0.36) x 10"-"6 m"2 x s"-"1. Furthermore, the correlation between "2"2"2Rn diffusion coefficient and ...

2003-06-01

390

Acceptance testing in digital systems of mammography. Protocols applicability  

International Nuclear Information System (INIS)

Acceptance testing of mammographic imaging systems technical is the first approach in order to guarantee that mammograms will be achieved with the minimum radiation dose compatible with an image quality suitable for diagnose purposes. The aim of this study is to assess the practical applicability of different protocols in acceptance test of digital mammographic systems. This study has been carried out on the results of the acceptance tests of five flat panel digital mammographic systems. Parameters established in the systems technical specifications and those evaluated in the consulted protocols were tested. Due to the fact that the legislation in our country does not demand to consider a specific protocol, the results obtained were also compared considering different existing protocols. Results show discrepancies between manufacturers limiting values and those established in the protocols. Some parameters, such as the automatic exposure ...

391

Transmission electron microscopy of strained In/sub y/Ga/sub 1//sub -//sub y/As/GaAs multiquantum wells: The generation of misfit dislocations  

Energy Technology Data Exchange (ETDEWEB)

We have investigated the generation and propagation of misfit dislocations in strained In/sub y/Ga/sub 1-//sub y/As/GaAs multiquantum wells grown by molecular-beam epitaxy, with cross-sectional transmission electron microscopy. The samples are of excellent optical quality, with multiquantum wells having well widths of 100 A, being characterized by excitonic linewidths and Stokes shifts of 1.5--2.5 and 1--2 meV, respectively. We have examined the growth of 2-..mu..m-thick multiquantum-well samples grown either directly on GaAs, or with an intermediate composition buffer layer, and for the cases of small (y = 0.07) and large (y = 0.16) misfits. It is seen that for the case of quantum wells with small misfit, grown directly on GaAs, metastable growth can be achieved. This is confirmed by low-temperature absorption measurements and from transmission electron microscopy experiments performed both before and after post-growth thermal annealing. In ...

1989-05-01

392

Optical second-harmonic generation in III-V semiconductors: Detailed formulation and computational results  

Science.gov (United States)

In an earlier paper (Phys. Rev. Lett. 66, 41 (1991)), we calculated both the dielectric constant ({epsilon}{sub {infinity}}) and the nonlinear optical susceptibilities for second-harmonic generation ({chi}{sup (2)}) in the static limit for AlP, AlAs, GaP, and GaAs in the local-density approximation with and without a self-energy correction in the form of a scissors operator,'' including local-field effects. In this paper, we expand our presentation of this calculation. Agreement with experiment to within 15% for the nonlinear susceptibility is demonstrated where experiments are available (GaP and GaAs); the dielectric constants are in no worse than 4% agreement with experiment. The virtual hole'' contributions are reformulated to avoid large numerical cancellations in the case of near degeneracies. The virtual electron'' terms dominate over the virtual hole'' terms ...

1991-12-15

393

New materials for future generations of III-V solar cells  

Energy Technology Data Exchange (ETDEWEB)

Three- and four-junction III-V devices are proposed for ultrahigh-efficiency solar cells using a new 1-eV material lattice-matched to GaAs, namely, GaInNAs. We demonstrate working prototypes of a GaInNAs-based solar cell lattice-matched to GaAs with photoresponse down to 1 eV. Under the AM1.5 direct spectrum with all the light higher in energy than the GaAs band gap filtered out, the prototypes grown with base doping of about 10{sup 17}&hthinsp;cm{sup {minus}3} have open-circuit voltages ranging from 0.35 to 0.44 V, short-circuit current densities of 1.8 mA/cm{sup 2}, and fill factors from 61{percent} to 66{percent}. To improve on the current record-efficiency tandem GaInP/GaAs solar cell by adding a GaInNAs junction, the short-circuit current density of this 1-eV cell must be significantly increased. Because these low short-circuit current densities are due to short diffusion lengths, we have demonstrated a ...

1999-03-01

394

Variation of alpha-particle track diameter in CR-39 as a function of residual energy and etching conditions  

Energy Technology Data Exchange (ETDEWEB)

It has often been proposed that track diameter in etched detectors can be used for energy spectrometry. To test this proposition, the relationship between track diameter and energy of alpha particles, in the range 0.1-5.5 MeV, incident on CR-39 was studied. Two sets of detectors were irradiated by a collimated normally-incident beam of {alpha}-particles of different energies, using an Am-241 source. Different foils of the first set were etched for variable lengths of time in such a way that, in each case, the etchant reached the end of the latent track. Foils in the second set were etched for a fixed 'short' time of 2 h, for all {alpha}-energies. The linear rate of energy loss as well as the residual range of {alpha}-particles was determined by using Henke and Benton's computer program. It is found that, for 'short' etching times, the track diameter mimics the 'Bragg ...

1999-02-01

395

The IceCube Collaboration:contributions to the 30 th International Cosmic Ray Conference (ICRC 2007),  

Energy Technology Data Exchange (ETDEWEB)

This paper bundles 40 contributions by the IceCube collaboration that were submitted to the 30th International Cosmic Ray Conference ICRC 2007. The articles cover studies on cosmic rays and atmospheric neutrinos, searches for non-localized, extraterrestrial {nu}{sub e}, {nu}{sub {mu}} and {nu}{sub {tau}} signals, scans for steady and intermittent neutrino point sources, searches for dark matter candidates, magnetic monopoles and other exotic particles, improvements in analysis techniques, as well as future detector extensions. The IceCube observatory will be finalized in 2011 to form a cubic-kilometer ice-Cherenkov detector at the location of the geographic South Pole. At the present state of construction, IceCube consists of 52 paired IceTop surface tanks and 22 IceCube strings with a total of 1426 Digital Optical Modules deployed at depths up to 2350 m. The observatory also integrates the 19 string AMANDA subdetector, ...

2007-11-02

396

Gasoline from natural gas by sulfur processing. Quarterly technical progress report No. 2, October 1, 1993--December 31, 1993  

Energy Technology Data Exchange (ETDEWEB)

This report presents the work performed at the Institute of Gas Technology (IGT) during the second program quarter from October 1, 1993 to December 31, 1993, under Department of Energy (DOE) Contract No. DE-AC22-93PC92114. This program has co-ordinated funding for Task 1 from IGT`s Sustaining Membership Program (SMP), while DOE is funding Tasks 2--8. Progress in all tasks are reported. The overall objective of this research project is to develop a catalytic process to convert natural gas to liquid transportation fuels. The process consists of two steps that each utilize catalysts and sulfur containing intermediates: (1) to convert natural gas to CS{sub 2} and (2) to convert CS{sub 2} to gasoline range liquids. Experimental data will be generated to demonstrate the potential of catalysts and the overall process. During this quarter, progress in the following areas has been made. An existing unit at IGT was modified to accommodate the sulfur feedstocks and the higher temperatures ...

1994-02-01

397

Feasibility of fissile mass assay of spent nuclear fuel using {sup 252}Cf-source-driven frequency-analysis  

Energy Technology Data Exchange (ETDEWEB)

The feasibility was evaluated using MCNP-DSP, an analog Monte Carlo transport cod to simulate source-driven measurements. Models of an isolated Westinghouse 17x17 PWR fuel assembly in a 1500-ppM borated water storage pool were used. In the models, the fuel burnup profile was represented using seven axial burnup zones, each with isotopics estimated by the PDQ code. Four different fuel assemblies with average burnups from fresh to 32 GWd/MTU were modeled and analyzed. Analysis of the fuel assemblies was simulated by inducing fission in the fuel using a {sup 252}Cf source adjacent to the assembly and correlating source fissions with the response of a bank of {sup 3}He detectors adjacent to the assembly opposite the source. This analysis was performed at 7 different axial positions on each of the 4 assemblies, and the source-detector cross-spectrum signature was calculated for each of these 28 simulated measurements. The magnitude of the ...

1996-10-01

398

Uncertainties of retrospective radon concentration measurements by multilayer surface trap detector  

Energy Technology Data Exchange (ETDEWEB)

The detector for retrospective radon exposure measurements is developed. The detector consists of the multilayer package of solid-state nuclear track detectors LR-115 type. Nitrocellulose films works both as {alpha}-particle detector and as absorber decreasing the energy of {alpha}-particles. The uncertainties of implanted {sup 210}Pb measurements by two- and three-layer detectors are assessed in dependence on surface {sup 210}Po activity and gross background activity of the glass. The generalized compartment behavior model of radon decay products in the room atmosphere was developed and verified. It is shown that the most influencing parameters on the value of conversion coefficient from {sup 210}Po surface activity to average radon concentration are aerosol particles concentration, deposition velocity of unattached {sup 218}Po and air exchange rate. It is demonstrated that with ...

2006-07-01

399

Pulse Rise Time Characterization of a High Pressure Xenon Gamma Detector for use in Resolution Enhancement  

CERN Document Server

High pressure xenon ionization chamber detectors are possible alternatives to traditional thallium doped sodium iodide (NaI(Tl)) and hyperpure germanium as gamma spectrometers in certain applications. Xenon detectors incorporating a Frisch grid exhibit energy resolutions comparable to cadmium/zinc/telluride (CZT) (e.g. 2% (at) 662keV) but with far greater sensitive volumes. The Frisch grid reduces the position dependence of the anode pulse risetimes, but it also increases the detector vibration sensitivity, anode capacitance, voltage requirements and mechanical complexity. We have been investigating the possibility of eliminating the grid electrode in high-pressure xenon detectors and preserving the high energy resolution using electronic risetime compensation methods. A two-electrode cylindrical high pressure xenon gamma detector coupled to time-to-amplitude conversion electronics ...

2000-01-01

400

Physics of the {sup 252}Cf-source-driven noise analysis measurement  

Energy Technology Data Exchange (ETDEWEB)

The {sup 252}Cf-source-driven noise analysis method is a versatile measurements tool that has been applied to measurements for initial loading of reactors, quality assurance of reactor fuel elements, fuel processing facilities, fuel reprocessing facilities, fuel storage facilities, zero-power testing of reactors, verification of calculational methods, process monitoring, characterization of storage vaults, and nuclear weapons identification. This method`s broad range of application is due to the wide variety of time- and frequency domain signatures, each with unique properties, obtained from the measurement. The following parameters are obtained from this measurement: average detector count rates, detector multiplicities, detector autocorrelations, cross-correlation between detectors, detector autopower spectral densities, cross-power spectral densities between ...

1997-02-01

401

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

Energy Technology Data Exchange (ETDEWEB)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations

1983-01-01

402

Use of neutron and gamma ray spectral measurements and calculations to obtain dosimetric information for DT neutrons  

International Nuclear Information System (INIS)

Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1 MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 MeV is desirable. Key words: neutron--gamma spectra, spectrometry, kerma distributions, coupled multigroup calculations.

7871-01-01

403

Use of a predictor for total body potassium content: application to nutrition and hypertension  

International Nuclear Information System (INIS)

Total body potassium (TBK), measured at different institutions, has no reference standard for comparison. A useful reference formula, however, based on body size and age, has been derived at the Brookhaven National Laboratory. This formula was used to help calibrate a simple whole body counter for measuring total potassium and applied to nutrition and hypertension studies. A sodium iodide detector was used for counting gamma rays emitted by potassium-40 to estimate TBK. The mean ratio (+/- S.D.) of adjusted TBK measurements to predicted values was 1.002 +/- 0.047. The ratio of lean body mass estimated by the TBK measurement to that derived from skin fold thickness was 1.069 +/- 0.056. In hypertensives on low dose thiazide, the ratio of TBK measurements to predicted values was 0.994 +/- 0.052. Thus, our TBK measurements were adjusted in close agreement with a predictor formula, provided higher estimates of lean body mass than did skin fold ...

404

The magnetic spectrometer PAMELA for the study of cosmic antimatter in space  

Energy Technology Data Exchange (ETDEWEB)

In the framework of the RIM (Russian Italian mission) program, PAMELA is the experiment devoted to the accurate measurement of the positron and antiproton spectra from the very low energy thresh-old of 100 MeV up to more than 50 GeV, and to hunt antinuclei with sensitivity better than 10{sup -7} in the helium/helium ratio. A permanent magnet equipped by microstrip silicon sensors, measures the particle momentum with MDR=400 GV/c on GF=25 cm{sup 2} sr. An accurate ToF system, a 19 X{sub o} deep imaging calorimeter, an aerogel Cherenkov counter and a TRD detector complement the spectrometer in order an efficient e{sup +-}/p{sup +-} separation and some light isotope identification capability. The PAMELA experiment will be carried out on a 700 km high polar orbit, on board of the Earth-observation meteor-3A satellite, to be launched at the end of 1988.

1995-09-01

405

The Schenberg spherical antenna: status report  

International Nuclear Information System (INIS)

Full text. Here we present a status report of the Schenberg antenna, which started commissioning runs in September 2006 under the full support of FAPESP. In its first commissioning runs we tested three preliminary parametric transducer systems, which did not achieve a high enough performance for placing the antenna sensitivity in the range of the calibrator capacitor. Instead of improving the calibrator, making it capable of introducing a larger input force, we decided to go to a radical upgrading operation: replacing the three transducers for a complete set of six transducers, with better sensitivity and arranged according to the truncated icosahedron configuration, plus two extra ones; starting to install the dilution refrigerator; installing wires, cables, and amplifiers for the complete set of transducer circuits; and a new suspension and vibration isolation system for the cabling and microstrip antennas. We also have been developing a new set of transducers, microwave oscillators, ...

2009-09-14

406

TLD array for precise dose measurements in stereotactic radiation techniques  

International Nuclear Information System (INIS)

We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be ...

1996-12-01

407

Sampling and chemical analysis of smoke gas components from the SP Industry Calorimeter  

Energy Technology Data Exchange (ETDEWEB)

This report describes the sampling and chemical analyses of smoke gas components for combustion performed in the SP Industry Calorimeter, where continuous measurements of oxygen, carbon dioxide and carbon monoxide are an integrated part of the Calorimeter system. On-line measurements of nitrogen oxides and total amounts of unburnt hydrocarbons were performed. Hydrogen cyanide, hydrogen chloride and ammonia in the smoke were sampled and absorbed in impinger bottles and subsequently analyzed using wet chemical techniques. An adsorbent sampling system was designed to allow the identification and quantitative analysis of individual organic compounds in the smoke. Gas chromatography was utilized with a mass spectrometric detector for the identification and a FID for quantification of the total amounts as well as individual components. A procedure for cleaning the smoke gas duct in between the combustion experiments was designed and found to be effective. The materials ...

1995-12-31

408

Radon concentration measurements in the Amasra coal mine, Turkey  

Energy Technology Data Exchange (ETDEWEB)

In this study, the results of atmospheric radon measurements that were performed for the Amasra underground coal mine in Zonguldak bituminous coal basin (Turkey) are presented. The radon measurements were performed for 40 days between November 2004 and December 2004 using passive nuclear etched track detectors. The radon concentrations vary from a minimum value 49 Bq m{sup -3} in a site located at +40 m to a maximum value 223 Bq m{sup -3} in a site located at -100 m. Mean concentration is 117 (Bq m{sup -3}). This value is well below the action level of 500-1500 Bq m{sup -3} recommended by the International Commission on Radiological Protection (ICRP) (1993). The mean effective dose value for workers of this mine of 3.4 {mu} Sv per day was obtained. This result shows that protection against radiological hazards would not be necessary for workers of this mine.

2006-04-15

409

Pulmonary retention of lead: an experimental study in man  

Energy Technology Data Exchange (ETDEWEB)

This human investigation of lead absorption from the lungs utilized two forms of lead, lead chloride and lead hydroxide; the former was used in picogram amounts and the latter at microgram levels. These two species of lead were selected in an attempt to simulate the range of physicochemical properties found in atmospheric lead (urban air). Aerosols labeled with lead-203 were made of comparable aerodynamic size by using sodium chloride as the deposition-determining aerosol. After brief, mouthpiece exposures, 17 subjects were followed by serial counting with a thoracic array of scintillation detectors and two leg counters. Serial blood samples were also taken. The two exposure groups showed similar total deposition values (23 vs 26%) and the same biological retention halftimes, viz., 22.6 hr. When the retention data were corrected for blood-borne /sup 203/Pb, the biological halftimes for lung lead retention averaged 13.1 and 14.2 hr, respectively, and were not ...

1980-01-01

410

Proposal for a High Energy Nuclear Database  

Energy Technology Data Exchange (ETDEWEB)

The authors propose to develop a high-energy heavy-ion experimental database and make it accessible to the scientific community through an on-line interface. This database will be searchable and cross-indexed with relevant publications, including published detector descriptions. Since this database will be a community resource, it requires the high-energy nuclear physics community's financial and manpower support. This database should eventually contain all published data from Bevalac, AGS and SPS to RHIC and CERN-LHC energies, proton-proton to nucleus-nucleus collisions as well as other relevant systems, and all measured observables. Such a database would have tremendous scientific payoff as it makes systematic studies easier and allows simpler benchmarking of theoretical models to a broad range of old and new experiments. Furthermore, there is a growing need for compilations of high-energy nuclear data for applications including ...

2005-03-31

411

Production of intense negative ion beams in magnetically insulated diodes  

Energy Technology Data Exchange (ETDEWEB)

Production of intense negative ion beams in magnetically insulated diodes was studied in order to develop an understanding of this process by measuring the ion-beam parameters as a function of diode and cathode plasma conditions in different magnetically insulated diodes. A coral diode, a racetrack diode, and an annular diode were used. The UCI APEX pulse line, with a nominal output of 1MV, 140kA, was used under matched conditions with a pulse length of 50 nsec. Negative-ion intensity and divergence were measured with Faraday cups and CR-39 track detectors. Cathode plasma was produced by passive dielectric cathodes and later, by an independent plasma gun. Negative-ion currents had an intensity of a few A/cm{sup 2} with a divergence ranging between a few tenths milliradians for an active TiH{sub 2} plasma gun and 300 milliradians for a passive polyethelene cathode. Negative ions were usually emitted from a few hot spots on the cathode surface. ...

1988-01-01

412

Persistence of terbufos and its metabolites in soil and maize  

International Nuclear Information System (INIS)

Degradation of "1"4C terbufos was studied under greenhouse conditions. A mixture of "1"4C labelled compound (2.48 x 10"4 Bq of O-ethyl-1- "1"4C) und unlabelled compound (0.09 g of the granule formulation Counter 10 G) was applied to pots containing 750 g of sandy loam clay Ultisol soil with 4.9% organic matter and a cation exchange capacity of 7.6. Two treatments were established, one where maize (cultivar Cristiani) was grown and the other without plants. The soil and plants were extracted at 0, 4, 8, 16, 32 and 64 days and analyzed by a liquid scintillation counter, gas chromatography-flame photometric detector (GC-FPD) and autoradiography. The total "1"4C compounds extracted on day 64 were 31 #+-# 5.6% of the radioactivity applied in the treatments with plants and 46.1 #+-# 1.1% without plants. From the autoradiography results it can be concluded that all times the compounds identified by this technique were terbufos, terbufos sulphoxide and ...

1996-07-01

413

PET/MRI hybrid imaging: devices and initial results  

International Nuclear Information System (INIS)

The combination of functional and morphological imaging technologies such as positron emission tomography (PET) and X-ray computed tomography (CT) has shown its value in the clinical and preclinical field. However, CT provides only very limited soft-tissue contrast and exposes the examined patient or laboratory animal to a high X-ray radiation dose. In comparison to CT, magnetic resonance tomography (MRI) provides excellent soft-tissue contrast and allows for nuclear magnetic resonance spectroscopy (NMRS) or functional MRI (fMRI). Thus, the combination of PET and MRI has been pursued for several years. First approaches have succeeded using conventional photo multiplier tube (PMT) technology together with light fibers to transfer scintillation light away from the high magnetic field. Latest PET/MRI developments use solid-state light detectors that can be operated even at high magnetic fields. Initial pilot studies with prototype animal PET/MRI ...

2008-06-01

414

Operating the ATLAS data-flow system with the first LHC collisions.  

CERN Document Server

In this paper we will report on the operation and the performance of the ATLAS data-flow system during the 2010 physics run of the Large Hadron Collider (LHC) at 7TeV. The data-flow system is responsible for reading out, formatting and conveying the event data, eventually saving the selected events into the mass storage. By the second quarter of 2010, for the first time, the system will be capable of the full event building capacity and improved data-logging throughput. We will in particular detail the tools put in place to predict and track the system working point, with the aim of optimizing the bandwidth and the computing resource sharing, and anticipate possible limits. Naturally, the LHC duty cycle, the trigger performance, and the detector configuration influence the system working point. Therefore, numerical studies of the data-flow system capabilities have been performed considering different scenarios. This is crucial for the first ...

2011-01-01

415

Operating the ATLAS Data-Flow System with the First LHC Collisions  

CERN Document Server

In this paper we will report on the operation and the performance of the ATLAS data-flow system during the 2010 physics run of the Large Hadron Collider (LHC) at 7 TeV. The data-flow system is responsible for reading out, formatting and conveying the event data, eventually saving the selected events into the mass storage. By the second quarter of 2010, for the first time, the system will be capable of the full event building capacity and improved data-logging throughput. We will in particular detail the tools put in place to predict and track the system working point, with the aim of optimizing the bandwidth and the computing resource sharing, and anticipate possible limits. Naturally, the LHC duty cycle, the trigger performance, and the detector configuration influence the system working point. Therefore, numerical studies of the data-flow system capabilities have been performed considering different scenarios. This is crucial for the first ...

2010-01-01

416

Nuclear Reactor Sharing Program  

Energy Technology Data Exchange (ETDEWEB)

The Ohio State University Research Reactor (OSURR) is licensed to operate at a maximum power level of 500 kW. A pool-type reactor using flat-plate, low enriched fuel elements, the OSURR provides several experimental facilities including two 6-inch i.d. beam ports, a graphite thermal column, several graphite-isotope-irradiation elements, a pneumatic transfer system (Rabbit), various dry tubes, and a Central Irradiation Facility (CIF). The core arrangement and accessibility facilitates research programs involving material activation or core parameter studies. The OSURR control room is large enough to accommodate laboratory groups which can use control instrumentation for monitoring of experiments. The control instrumentation is relatively simple, without a large amount of duplication. This facilitates opportunities for hands-on experience in reactor operation by nuclear engineering students making reactor parameter measurements. For neutron activation analysis and ...

1994-09-01

417

Nitrous oxide in coastal waters  

Energy Technology Data Exchange (ETDEWEB)

Measurements of dissolved and atmospheric nitrous oxide (N{sub 2}O) are presented for three coastal environments: (1) the central North Sea, (2) the German Bight, and (3) the Gironde estuary. The contribution of coastal regions to the oceanic emissions of atmospheric N{sub 2}O were also determined. N{sub 2}O was measured with a gas chromatograph equipped with an electron capture detector and analyzed. The surface waters of the central North Sea and the German bight were found to be near equilibrium with the overlying atmosphere, while the mean saturation in the Gironde estuary was 132%. Mean saturations in coastal regions without estuaries or upwelling phenomena were only slightly higher than in the open ocean. When estuaries and regions with upwelling are included, however, approximately 60% of the oceanic N{sub 2}O flux is attributable to coastal regions. A review of published data indicated that previous studies have seriously underestimated ...

1996-03-01

418

Muon trigger, flavour tagging and physics performance of the LHCb experiment; Trigger a muons, etiquetage de la saveur et performances physiques de l'experience LHCb  

Energy Technology Data Exchange (ETDEWEB)

The LHCb experiment that is being settled in CERN is dedicated to the study of CP violation and rare decays in the field of beauty hadrons. The phenomenological background necessary to an adequate understanding of the physics of flavor is presented in the first chapter, it is shown how the flavordynamics can open the way to new physics. The second chapter is dedicated to a brief presentation of the LHCb detector. Two aspects of the design of the muon trigger are more detailed: the radiation resistance of the opto-electronic transmitters and the simulated performances of the trigger. The third chapter reviews the tasks linked to the tagging of the savors of B mesons which will be an important step in all the experiments made at LHCb. The recent progress in heavy savor physics as well as the expected contribution of LHCb in this field are presented in the fourth chapter, especially the search for new physics in penguin diagrams b {yields} s.

2007-10-15

419

Modified Fragmentation Function in Heavy Ion Collisions at RHIC via Direct photon-Jet Measurements  

CERN Document Server

The presented results are the first measurements at RHIC for direct $\\gamma$-charged hadron azimuthal correlations in heavy ion collisions. We use these correlations to study the color charge density of the medium through the medium-induced modification of high-p$_T$ parton fragmentation. Azimuthal correlations of direct photons at high transverse energy (8 $<$ p$_T$ $<$ 16 GeV) with away-side charged hadrons of transverse momentum (3 $<$ p$_T$ $<$ 6 GeV/c) have been measured over a broad range of centrality for $Au+Au$ collisions and $p+p$ collisions at $\\sqrt{s_{NN}}$ = 200 GeV in the STAR experiment. A transverse shower shape analysis in the STAR Barrel Electromagnetic Calorimeter Shower Maximum Detector is used to discriminate between the direct photons and photons from the decays of high p$_T$ $\\pi^{0}$. The per-trigger away-side yield of direct $\\gamma$ is smaller than from $\\pi^{0}$ trigger at the same centrality class. ...

2008-01-01

420

Measurement of \\chi_cJ--> K+K-K+K-  

CERN Document Server

Using 14M psi(2S) events taken with the BES-II detector, chi_cJ-->K+K-K+K- decays are studied. For the four-kaon final state, the branching fractions are B(chi_c0,1,2 -->K+K-K+K-)=(3.47\\pm 0.22\\pm 0.48)\\times 10^{-3}, (0.68\\pm 0.13\\pm 0.10)\\times 10^{-3}, and (1.88\\pm 0.18\\pm 0.28)\\times 10^{-3}. For the \\phi K+K- final state, the branching fractions, which are measured for the first time, are B(chi_c0,1,2-->\\phi K+K-)=(1.02\\pm 0.22\\pm 0.15)\\times 10^{-3}, (0.44\\pm 0.14\\pm 0.07)\\times 10^{-3}, and (1.46\\pm 0.21\\pm 0.22)\\times 10^{-4}. For the \\phi\\phi final state, B(chi_{c0,2}-->\\phi\\phi)=(0.94\\pm 0.21\\pm 0.14)\\times 10^{-3} and (1.48\\pm 0.26\\pm 0.23)\\times 10^{-3}.

2006-01-01

421

MTX diagnostic and timing system for free-electron laser heating experiments  

International Nuclear Information System (INIS)

In the microwave tokamak experiment (MTX) program, we are concentrating on experiments using intense, free-electron laser (FEL) generated microwave pulses. In initial FEL experiments, several diagnostic instruments were operated during injection of microwave pulses with peak powers to 0.2 GW at durations of 10 ns. Fixed and spatially scanning microwave detectors and receivers and a 48-element calorimeter on the inside wall of MTX diagnosed the GW-level FEL microwave pulses. With these diagnostics, linear-wave absorption and efficiencies of transmission through the quasi-optical transport system were studied. In addition, several radially resolved measurements of plasma density, temperature, and emission were made during FEL injection and were used in the analysis of microwave absorption data. A timing system, slaved to the FEL pulse arrival time, is capable of accuracy to a few nanoseconds in order to allow measurement of heating effects on the ...

422

Light Sterile Neutrino Effects at theta_13-Sensitive Reactor Neutrino Experiments  

CERN Document Server

We study the impact of very light sterile neutrinos (Delta m^2_new around 1 to 10 times 10^(-2) eV^2, sin^2 2theta_new<10^(-1)) on upcoming theta_13-driven reactor antineutrino experiments like Double-CHOOZ and Daya Bay. Oscillations driven by these vales of Delta m^2_new affect data in the near and far detectors differently and hence potentially modify the capability of these experimental setups to constrain and measure sin^2 2theta_13. We find that the hypothesis theta_new different from zero negatively impacts one's ability to either place an upper bound on sin^2 2theta_13 in the advent of no oscillation signal or measure sin^2 2theta_13 if a theta_13-driven signal is observed. The impact of sterile neutrino effects, however, depends significantly on one's ability to measure the recoil positron energy spectrum. If sin^2 2theta_new is larger than 10^(-2), upcoming theta_13-driven reactor antineutrino experiments should be able to measure ...

2008-01-01

423

Feasibility study of large combined function magnets for the Jefferson lab 12 GeV upgrade  

CERN Document Server

The 12 GeV upgrade at Jefferson Lab has identified two new large spectrometers as Physics detectors for the project. The first is a 7.5 Gev/c 35 m-sr. spectrometer that requires a pair of identical Combined Function Superconducting Magnets (CFSM) that can simultaneously produce 1.5 T dipole fields and 4.5 T/m quadrupole fields inside a warm bore of 120cm. The second is an 11 GeV/c 2 m-sr. spectrometer that requires a CFSM that simultaneously produces a dipole field of 4.0 T and a quadruple field of 3.0 T/m in a 60 cm warm bore. Magnetic designs using TOSCA 3D have been performed to realize the magnetic requirements, provide 3d fields for optics analysis and produce field and force information for the engineering feasibility of the magnets. A two-sector cos( theta )/cos(2 theta ) design with a low nominal current density, warm bore and warm iron design has been selected and analyzed. These low current densities are consistent with the limits for a cryostable ...

2005-01-01

424

Experimental research on passive #gamma# scanning system at hot-cell for hull monitoring  

International Nuclear Information System (INIS)

A simulated hull monitoring system based on passive #gamma# ray scanning was set-up in K-01 hot-cell, which consists of a simulated hull basket, a collimator system, a 150 cm"3 HPGe detector and an ORTEC-919 multichannel buffer-computer system. Six different kinds of experimental set-up were established to simulate the variations of #gamma# ray source term distribution (partly concentration) and the variations of matrix density (+46.1%). The experimental results show that the biases of peak area is better than -25.3% for "1"3"7Cs 662 keV #gamma# rays and -18.6% for "1"4"4Ce-"1"4"4Pr 2186 keV #gamma# rays. The hardness of pulse height spectrum is demonstrated to show that the peak area ratio of 2186 keV to 662 keV varies from 380 to 72 when the thickness of lead filter varies form 5 mm to 30 mm. Also studied are the design parameters of collimator system.

425

Dynamic behaviors of sulfur evolved in the gas phase from pyrolysis of six Chinese coals  

Energy Technology Data Exchange (ETDEWEB)

Dynamic behaviors of gaseous sulfur-containing compounds evolved from pyrolysis of six Chinese coals were studied in the temperature range of up to 800{sup o}C under N{sub 2} and H{sub 2}. The released amount of total sulfur-containing gases was traced by an online flame photometric detector (FPD). Simultaneously, the changes of different sulfur forms, including H{sub 2}S, SO{sub 2}, COS and CS{sub 2}, also were investigated using an online mass spectrometer (MS). FPD results show that the effect of H{sub 2} on gaseous sulfur evolved is complex, which promoted certain peak and suppresses other peaks. Based on the data from MS, it is suggested that a series of competitive reactions between active sulfur and other active matters during pyrolysis may impact on the sulfur form in gas phase. Interactions between active sulfur-containing intermediates and the coal matrix are attributed to be the main factor determining the dynamic behavior.

2006-07-01

426

Cosmic gamma ray detection and discovery potential with the AMS-2 spectrometer; Detection de rayons {gamma} cosmiques et potentiel de decouvertes avec le spectrometre AMS-02  

Energy Technology Data Exchange (ETDEWEB)

Yet designed to measure charged component of the cosmic rays, the foreseen Alpha Magnetic Spectrometer (AMS-02) could also release {gamma}-ray studies, in the energy range from GeV to TeV, using the tracker system, for {gamma}-rays converted in e{sup +}e{sup -} pair, and the electromagnetic calorimeter. In the first part of the thesis are described the calibrations and the performances of the engineering model of the calorimeter, obtained from the analysis of data taken during a test-beam performed at CERN in July 2002. In the second part of the thesis, the AMS-02 discovery potential for {gamma}-astrophysics is presented. While exposure maps of the {gamma}--sky are computed for one year of data taking with the {gamma}--detectors, the acceptance of the calorimeter is obtained from Monte-Carlo simulations. The AMS-02 potential is then estimated for signals from the Vela pulsar and for some supersymmetric signals from the Galactic Center. (author)

2004-12-15

427

Atomic beam spectrometer using a LiF analyzer crystal  

International Nuclear Information System (INIS)

An energy analyzer has been constructed and operated in UHV for the purpose of analyzing the energy of neutral atoms scattered from solid surfaces. The analyzer consists of a LiF single crystal located at an angle close to the normal to the sample crystal so that the diffraction pattern obtained by scanning the LiF crystal yields the energy of the scattered atoms. Two designs which have been used are described. The temperature of both sample and analyzer crystal is near 20 K and once cleaned they can be maintained in the state of initial preparation for many weeks. The sample was a (001) Cu surface in this case. Such an energy analyzer can only be used, in most cases, for He atom scattering although Ne atoms could be used if the scattered intensities were adequate. The detector developed in this study is able to detect about 2 x 10"5 atoms/s. The resolution of the spectrometer depends on the incident energy of the atom and is about 1 meV at an ...

1978-01-01

428

Alloying effect on K to L shell vacancy transfer probabilities in 3d transition metals  

British Library Electronic Table of Contents (United Kingdom)

The alloying effects on K to L shell vacancy transfer probabilities (?KL) in 3d transition metals have been carried out by X-ray fluorescence studies of various alloy compositions. K X-ray intensity ratios of Ti, Cr, Fe, Co, Ni, and Cu elements in the FexNi1?x, FexCr1?x, NixCr1?x, FexCryNi1?(x+y), TixNi1?x, TixCo1?x, and CoxCu1?x alloys have been measured following excitation by 22.69keV X-rays from a 10 mCi 109Cd radioactive point source and ?KL values for alloying elements have been determined from these ratios. The spectrum of characteristic K-X-ray photons from samples were detected with a high resolution Si(Li) detector coupled to a 4 K multichannel analyzer. The present investigation makes it possible to ...

2010-01-01

429

The hunt for ?13 at the Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The Daya Bay reactor neutrino experiment is located at the Daya Bay nuclear power plant in Shenzhen, China. The experiment deploys eight 'identical' antineutrino detectors to measure antineutrino fluxes from six 2.9 GWth reactor cores in three underground experimental halls at different distances. The target zone of the Daya Bay detector is filled with 20 t 0.1% Gd doped LAB liquid scintillator. The baseline uncorrelated detector uncertainty is ?0.38% using current experimental techniques. Daya Bay can reach a sensitivity of sin22?13<0.01 with baseline uncertainties after 3 years of data taking.

2010-03-30

430

The cross-coupled interferometer for gravitational wave detection  

International Nuclear Information System (INIS)

The cross-coupled interferometer is a new design for interferometric gravitational wave detectors. Similar to the baseline gravitational wave detectors proposed for Advanced LIGO, it uses long-arm cavities in which the signal is generated. The signal fields are then extracted from the arm cavities with an additional cavity behind the long-arm cavities. The tuning of this signal extraction cavity and the parallel tuning of the signal recycling mirror can be used to optimize the peak frequency and the bandwidth of the detector independently. If we replace the signal recycling mirror by a small cavity, it is possible to amplify signals in two different frequency bands.

2002-04-07

431

Sudbury neutrino detector  

International Nuclear Information System (INIS)

The proposed Sudbury Neutrino Observatory is based on a Cherenkov detector which has a total of 1000 tonne of heavy water and 1800 tonne of light water for its sensitive volume. The detector is optimized for the measurement of extra-terrestrial low energy electron neutrinos and electron antineutrinos spectra as well as the total neutrino flux independent of neutrino flavours. It will delineate the Standard Solar Model and neutrino propagation aspects of the solar neutrino problem, provide detailed information on the dynamics of stellar collapse and measure neutrino masses and oscillation parameters with high sensitivity.

432

Nuclear borehole logging using lithium detector assemblies  

International Nuclear Information System (INIS)

A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).

1991-11-01

433

Applications of the Long-Range Alpha Detector (LRAD) technology to low-level radioactive waste management  

Energy Technology Data Exchange (ETDEWEB)

Long-Range Alpha Detector (LRAD) systems are designed to monitor alpha contamination by measuring the number of ions in the air. Alpha particles are a form of ionizing radiation and a typical 5-MeV alpha particle will create about 150,000 ion pairs in air. Field tests at various DOE sites have shown that LRAD Surface Soil Monitors (SSM), Sample Monitors, and Object Monitors are faster and more sensitive than traditional alpha detectors for measuring alpha contamination. This paper discusses the various applications of LRAD technology to low-level radioactive waste management.

1993-12-01

434

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

Energy Technology Data Exchange (ETDEWEB)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

1991-05-01

435

A high stopping power, large acceptance Bragg curve spectrometer for heavy ion detection  

International Nuclear Information System (INIS)

A large acceptance, high stopping power Bragg curve spectrometer has been developed for use in coincidence experiments with heavy ions. The electron collection fields are radial and position information is obtained from a resistive anode. The detector is 60 cm deep and operates at pressures of up to 2.5 atm of P-10 gas. It is mated to a scattering chamber which allows it to be moved out of plane during coincidence measurements. Factors affecting the performance of the detector are discussed, and results obtained with the detector are presented. (orig.).

436

A PDA-Based ECG Beat Detector for Home Cardiac Care.  

Science.gov (United States)

Recent rapid growth in mobile computing technologies enables telemedicine applications to operate on mobile devices. Our focus is on the design of an integrated electrocardiogram (ECG) beat detector on a Personal Digital Assistant (PDA) platform for the health screening process. The ECG beat detector module will be supported by the PDA version of Personal Health Information Management System (PHIMS) and Facilitated Accurate Referral Management System (FARMS) through wireless network infrastructure as a home-based mobile cardiac monitoring solution. PMID:17282192

2005-01-01

437

Comparison of dose calculation algorithms in phantoms with lung equivalent heterogeneities under conditions of lateral electronic disequilibrium  

International Nuclear Information System (INIS)

An extensive set of benchmark measurement of PDDs and beam profiles was performed in a heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of several detectors and compared against the predicted dose values by different calculation algorithms in two treatment planning systems. PDDs were measured with TLDs, plane parallel and cylindrical ionization chambers and beam profiles with films. Additionally, Monte Carlo simulations by meansof the PENELOPE code were performed. Four different field sizes (10x10, 5x5, 2x2, and1x1 cm"2) and two lung equivalent materials (CIRS, #rho#_e"w=0.195 and St. Bartholomew Hospital, London, #rho#_e"w=0.244-0.322) were studied. The performance of four correction-based algorithms and one based on convolution-superposition was analyzed. The correction-based algorithms were the Batho, the Modified Batho, and the Equivalent TAR implemented in the Cadplan (Varian) treatment planning system and ...

2004-10-01

438

View Record - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 13, 2011 ... This 360-degree mosaic of images from the navigation camera on ... The Radiation Assessment Detector, shown prior to its September 2010 ...

439

The CDF intermediate silicon layers detector  

Energy Technology Data Exchange (ETDEWEB)

The intermediate silicon layers detector (ISL) was proposed as a part of the upgraded CDF detector at the RUN-II of the Tevatron mean value of pp collider at Fermilab, scheduled to start in year 2000. The ISL is a large-radius (20-30 cm) silicon tracker with a total active area of about 3.5 m. Located in the region between the silicon vertex detector and the central outer tracker, the ISL will allow tracking in the forward region and significantly improve it in the central area. Together with the SVX II the ISL forms a standalone, 3D silicon tracker. The challenge is to build a low-cost device which provides precise 3 D tracking in a approximately equal to 2 m long area with a minimal amount of material for the supporting structure. The conceptual design and the status of the project are reviewed.

1999-11-01

440

Space Images - NASA Jet Propulsion Laboratory  

Science.gov (United States)

Jan 18, 2011 ... The Radiation Assessment Detector, shown prior to its September 2010 ... This 360-degree panorama shows the vista from the location where ...

441

Radon concentration measurements by means of nuclear tracks detector with image analysis  

International Nuclear Information System (INIS)

English 1998 p. 124 Poland Antanasijevic, R. Vukovic, J. Novakovic, V. Tasic,

1998-09-15

442

Photoconductive ultraviolet detectors based on ZnO films  

British Library Electronic Table of Contents (United Kingdom)

Properties of photoconductive ultraviolet detectors fabricated on ZnO films were presented. Highly c-axis oriented ZnO films were grown on glass substrates by pulsed laser deposition. Ultraviolet photodetectors were fabricated based on metal-semiconductor-metal planar structures. The photoresponsivity and the quantum efficiency are much higher in the ultraviolet range than in the visible range, and the peak values are around 360nm. Photocurrent transients show that the detector has a large photocurrent with the peak value of 2.8mA, and a slow photoresponse with a rise time of 5min and a decay time of 7min. The response curve of the detector is fitted well with exponential curve. The large photocurrent should result from the both effects of the accumulation of conduction electrons and the d...

2006-01-01

443

Particle identification for heavy ions in a time-of-flight spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A time-of-flight (TOF) spectrometer has been constructed at the JAERI 20 MV tandem accelerator facility. A position-sensitive start detector, which consists of a thin carbon foil, microchannel plates and a resistive plate, was developed for the TOF measurements through the spectrometer. The time and position resolutions obtained were 120 ps and 0.3 mm for ..cap alpha.. particles from /sup 241/Am, respectively. A two-dimensional position-sensitive detector was also developed to measure the solid angle of the spectrometer and the maximum solid angle obtained was 9.5 msr. As a particle detector a Bragg curve ionization chamber was developed. From the Bragg curves of heavy ions in the detector, energies, ranges and Bragg curve peaks were measured and used for particle identification. The resolving power Z/..delta..Z of the atomic number was about 50.

1982-05-01

444

Optimal detector deployment for the CANDU-600 pressurized heavy water reactor  

Science.gov (United States)

An optimal deployment pattern of flux mapping detectors for a Canada uranium-deuterium (CANDU)-600 pressurized heavy water reactor (PHWR) is determined by obtaining an optimal feedback relationship between flux measurements and zone controllers. The reactor core is modeled with a time-dependent two-group, two-dimensional diffusion equation, and flux perturbation are expressed by model expansions. The modal expansion coefficients are used as elements of the state vector representing the system dynamics. An optimal feedback matrix connecting the flux measurement vector to the control vector is derived by minimizing a quadratic performance index involving both the state and control vectors. We obtain the detector effectiveness in terms of the optimal feedback matrix and determine optimal detector locations for the Wolsung Unit 1 reactor in Korea. We have tested the methodology through evaluation of flux maps generated through ...

1992-01-01

445

Linewidth-broadened Fabry-Perot cavities within future gravitational wave detectors  

International Nuclear Information System (INIS)

The bandwidth of LIGO-like terrestrial interferometric gravitational wave detectors is set by the pole of the Fabry-Perot cavities within the arms of the Michelson interferometer. This constraint arises because the gain of gravitational wave-induced signal sidebands is limited to frequencies within the linewidth of the cavities. The nature of standard Fabry-Perot cavities is such that one cannot independently adjust for increased gain without suffering a loss of bandwidth. If these quantities could be decoupled, the resulting improvement in bandwidth may lead to viable high frequency detectors. A pair of anti-parallel diffraction gratings within a Fabry-Perot cavity can increase the bandwidth of a LIGO-scale detector by a factor of #approx#1000.

2004-03-07

446

LAMBDA - IRAS Faint Source Survey Plates - LAMBDA - NASA  

Science.gov (United States)

Apr 18, 2008 ... The FSS was produced by point-source filtering the individual detector data ... a 1-sigma noise map; and a coverage map giving the count of ...

447

Development of a new #gamma#-ray detector for PEM applications  

International Nuclear Information System (INIS)

The authors are developing a high specificity detector for detecting the increased metabolic rate of breast tumors. Positron emission mammography (PEM) provides a highly efficient, high spatial resolution positron imaging system. PMT plays a very important role in PEM detectors, because most of the systems consist of scintillator arrays coupled with PMT. Our detector is composed of 20 x 20 arrays of 2 mm x 2 mm x 20 mm of Bi_4Ge_3O_1_2 (BGO) scintillators and a novel flat panel position-sensitive PMT (FP-PS-PMT)-Hamamatsu R8400-00-M256. Spatial resolutions of 2.0 mm FWHW and energy resolutions of 23% FWHM are achieved. (authors)

2007-05-01

448

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

Energy Technology Data Exchange (ETDEWEB)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-15

449

Developement of the method for realization of spectral irradiance scale featuring system of spectral comparisons  

International Nuclear Information System (INIS)

Realization of the scale of spectral responsivity of the detectors in the Directorate of Measures and Precious Metals (DMDM) is based on silicon detectors traceable to LNE-INM. In order to realize the unit of spectral irradiance in the laboratory for photometry and radiometry of the Bureau of Measures and Precious Metals, the new method based on the calibration of the spectroradiometer by comparison with standard detector has been established. The development of the method included realization of the System of Spectral Comparisons (SSC), together with the detector spectral responsivity calibrations by means of a primary spectrophotometric system. The linearity testing and stray light analysis were preformed to characterize the spectroradiometer. Measurement of aperture diameter and calibration of transimpedance amplifier were part of the overall experiment. In this paper, the developed method is ...

2010-10-01

450

DESIGN, IMPLEMENTATION AND TESTING OF ... - LAMBDA - NASA  

Science.gov (United States)

FIG. 4. Power Spectral Density of the MAP W11 radiometer. The red and black traces are the power spectral density measurements of the two detectors on the ...

451

Conceptual Design of a Support Structure and an Assemble of Detectors Inside a Large Solenoid  

CERN Document Server

In this note we describe a support structure which will hold detector systems (ITS, TPC, TOF) inside the large solenoid. An overall view of ALICE detector is shown on Fig.1. The support structure consists of 2 rings which fixed to an iron yoke and spokes which connect TPC and TOF to these rings. The ITS is connected by spokes to TPC end caps. Between coils there are 7cm spacings which will allow to fix rings to the yoke this support structure will allow to assemble ITS, TPC and TOF together (Fig.2) somewhere on the surface and then transport to the pit and install in the magnet. Two rings (1) are connected with four bars (2). On the bottom bars there are rolls (3) which will allow smoothly insert detectors into the magnet. Spokes (4) are uniformly distributed.

1993-01-01

454

AeroSpace Information for a Changing World - NASA Technical ...  

Science.gov (United States)

Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...

455
456

A Quantum-Enhanced Prototype Gravitational-Wave Detector  

CERN Document Server

The quantum nature of the electromagnetic field imposes a fundamental limit on the sensitivity of optical precision measurements such as spectroscopy, microscopy, and interferometry. The so-called quantum limit is set by the zero-point fluctuations of the electromagnetic field, which constrain the precision with which optical signals can be measured. In the world of precision measurement, laser-interferometric gravitational wave (GW) detectors are the most sensitive position meters ever operated, capable of measuring distance changes on the order of 10^-18 m RMS over kilometer separations caused by GWs from astronomical sources. The sensitivity of currently operational and future GW detectors is limited by quantum optical noise. Here we demonstrate a 44% improvement in displacement sensitivity of a prototype GW detector with suspended quasi-free mirrors at frequencies where the sensitivity is shot-noise-limited, by ...

2008-01-01

457

8 - NASA Technical Report Server (NTRS)  

Science.gov (United States)

feature similar to the face detection in Intel's OpenCV library, implement it in Matlab code, and test the performance of the new ROI detector against the ...

458

Field test for treatment verification of an in-situ enhanced bioremediation study  

Energy Technology Data Exchange (ETDEWEB)

Due to a leakage from a 12-inch pressurized diesel steel pipe four years ago, an area of approximately 30,000 square meters was contaminated. A pilot study applying the technology of in-situ enhanced bioremediation was conducted. In the study, a field test kit and on-site monitoring equipment were applied for site characterization and treatment verification. Physically, the enhanced bioremediation study consisted of an air extraction and air supply system, and a nutrition supply network. Certain consistent sampling methodology was employed. Progress was verified by daily monitoring and monthly verification. The objective of this study was to evaluate the capabilities of indigenous microorganisms to biodegrade the petroleum hydrocarbons with provision of oxygen and nutrients. Nine extraction wells and eight air sparging wells were installed. The air sparging wells injected the air into geoformation and ...

1995-09-01

459

Exotic nuclear spectroscopy: towards the doubly-magic Sn-100  

International Nuclear Information System (INIS)

Modern nuclear spectroscopy boosts the study of the nuclear matter towards extreme conditions: large excitation energies, high spins, and new nuclear species with unusual ratio between the numbers of neutrons and protons. One of the 'exotic' nuclear regions, practically not studied until now, is the upper part of the N=Z line, from about N#approx#Z#approx#36 to Sn-100, probably the heaviest bound nucleus with N=Z. These nuclei lie close to the proton-drip line. Due to their special composition, it is expected that their study will reveal some phenomena which are less encountered in the nuclei studied till now. In particular, of outstanding interest is the fact that these are the only nuclei which may provide information on the properties of the neutron-proton pairing forces. In spite of its large interest, this nuclear region is exceedingly difficult to reach with the present techniques. The lecture ...

2001-10-18

460

Comparison Between Active and Passive Techniques for Radon Gas and Working Level measurements, El-Allouga Mine, Sinai, Egypt  

International Nuclear Information System (INIS)

Two different techniques were used for measuring Rn-gas concentrations and Working Level (WL) in U-exploration galleries at El-Allouga Mine, Sinai, Egypt. The active techniques used EDA(RDA-200) with calibrated Lucas cell and Tri-Met-372 instruments and passive techniques used four different types of SSNTD. Twenty eight (28) stations inside the studied tunnels were located covering the different environmental conditions. The measurements were carried out during summer time, in the ventilated sector (16 stations), the average tunnel air temperature was 24.4 #+-# 2.2 degree C and relative humidity 38%. In the non-ventilated sector (12 stations), the average tunnel air temperature was 22.2#+-#0.4 degree C and relative humidity 70%. The Rn-gas concentrations using EDA(RDA-200) and calibrated Lucas cell, in the ventilated sector averaged 11.966 p Ci/l, while in the non-ventilated stations averaged 786.21 p Ci/l. Also for the Tisvoglu method, the values of (WL) in the ...

2007-04-22

461

The greenhouse gases N{sub 2}O, CH{sub 4} and CO{sub 2} in coniferous forest soils as influenced by nitrogen input, acidity, moisture and temperature; Drivhusgassene N{sub 2}O, CH{sub 4} og CO{sub 2} i barskogsjord under paavirking av N-tilfoersel, surhet, fuktighet og temperatur  

Energy Technology Data Exchange (ETDEWEB)

The thesis relates to an investigation done on greenhouse gases in coniferous forest soils. The production of nitrous oxide (N{sub 2}O) and carbon dioxide (CO{sub 2}), and the consumption of methane (CH{sub 4}) in a temperate forest soil were studied by a rapid and sensitive gas chromatographic (GC) method for analysing all three greenhouse gases at or below ambient levels. Gas fluxes were measured in soil incubation and lysimeter experiments. 15 soil samples were taken at random within a 100 m{sup 2} area in a Norway spruce forest stand (Picea abies). The fluxes of N{sub 2}O, CH{sub 4} and CO{sub 2} were measured under standardized laboratory incubation conditions to investigate spatial variability in relation to other factors such as nitrogen (N) mineralization rate, nitrification rate, organic carbon (OC), total N and pH. The effects of temperature, soil moisture content, and ammonium addition were also studied in an incubation experiment. A ...

1994-07-01

462

Long pulse chemical laser. Final technical report  

Energy Technology Data Exchange (ETDEWEB)

This report covers the technical effort through February, 1989. This effort was directed towards the technology associated with the development of a large scale, long pulse DF-CO{sub 2} chemical laser. Optics damage studies performed under Task 1 assessed damage thresholds for diamond-turned salt windows. Task 2 is a multi-faceted task involving the use of PHOCL-50 for laser gain measurements, LTI experiments, and detector testing by LANL personnel. To support these latter tests, PHOCL-50 was upgraded with Boeing funding to incorporate a full aperture outcoupler that increased its energy output by over a factor of 3, to a full kilojoule. The PHOCL-50 carbon block calorimeter was also recalibrated and compared with the LANL Scientech meter. Cloud clearing studies under Task 3 initially concentrated on delivering a Boeing built Cloud Simulation Facility to LANL, and currently involves design of a Cold Cloud Simulation ...

1989-02-01

463

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO{sub 2}). The experimental results highlight the matrix effects and the measurement inaccuracies due to ...

2006-03-15

464

Comparative study of different methodologies for quantitative rock analysis by Laser-Induced Breakdown Spectroscopy in a simulated Martian atmosphere  

International Nuclear Information System (INIS)

Laser-Induced Breakdown Spectroscopy was selected by NASA as part of the ChemCam instrument package for the Mars Science Laboratory rover to be launched in 2009. ChemCam's Laser-Induced Breakdown Spectroscopy instrument will ablate surface coatings from materials and measure the elemental composition of underlying rocks and soils at distances from 1 up to 10 m. The purpose of our studies is to develop an analytical methodology enabling identification and quantitative analysis of these geological materials in the context of the ChemCam's Laser-Induced Breakdown Spectroscopy instrument performance. The study presented here focuses on several terrestrial rock samples which were analyzed by Laser-Induced Breakdown Spectroscopy at an intermediate stand-off distance (3 m) and in an atmosphere similar to the Martian one (9 mbar CO2). The experimental results highlight the matrix effects and the measurement inaccuracies due to the noise accumulated ...

2006-03-01

465

Characterisation of thin films on rough steel substrates by FTIR microscopy and imaging  

International Nuclear Information System (INIS)

Complete text of publication follows. According to the new European regulations (Restrictions of Hazardous Substance Directive), there is an emerging demand for environmental friendly metal treatments instead on formerly used chromate conversion coating technique. The aim of the present investigations was to characterise and compare silicon containing protective thin layers on roughened galvanized steel surfaces (with average roughness of 0.7 microns), using FTIR microscopy and imaging techniques. The silicon containing coatings were produced either by Chemical Vapour Deposition (CVD) or by wet chemical treatment using liquid silane. FTIR techniques offer new possibilities in the characterisations and chemical mapping of differently coated thin films, besides SEM+EDS, AFM, nanoindentation, XPS measurements (P. Nemeth et al., Materials Science Forum, 589 (2008) 433-438). All measurements were carried out by a Varian FTS-7000 spectrometer with a 'Stingray' microscope configuration ...

466

Application of passive type radon detectors to find fissures in banks caused by the southern Hyogo prefectural earthquake in Japan  

International Nuclear Information System (INIS)

Innumerable fissures were formed widely in Hanshin area in Japan by the former southern Hyogo prefectural earthquake occurred on Jan.17, 1995. In this study, as a preliminary investigation, we applied passive type radon detector Pico-Rad (U.S. Packard Instrument Co. Ltd.) with hemispheric plastic cover over them around the fissure along on the bank of two reservoirs to examine whether there is possibility to find fissures using the characteristics of "2"2"2Rn migration. One of the reservoir, Taniyamakami-ike, is located at the north of the Awaji-shima island at a distance of about 4 km from the seismic center of this earthquake. On the whole, "2"2"2Rn exhalation rates were high on a line of 2 m below the edge of the bank and got lower in proportion to the distance from this line. Those top of the bank had middle values among the lines. The mean "2"2"2Rn exhalation rate was 4.7 mBq m"-"2 s"-"1, and in these data we found some singularly high ...

467

The difference between standard and average efficiencies of multijunction compared with single-junction concentrator cells  

Energy Technology Data Exchange (ETDEWEB)

The theoretical performance of ideal single- and multijunction cells are compared at 100xconcentration under a range of cloudless-sky conditions. The sensitivities of device performance to cell temperature and spectral variations are shown to depend on the number of junctions (one, two or three), the way in which the junctions are connected (series, parallel or independent), and the band gaps of the devices. The average performances of all of the multijunction devices surpass that of a single-junction GaAs device, but the inconsistency in performance of some of the multijunction devices is significant for large variations in cell temperature and incident spectrum. The choice of band gap and connection scheme is more important than the number of junctions in determining the consistency of device performance. (orig.).

1991-05-01

468

Status of nonsilicon photovoltaic solar cell research  

Energy Technology Data Exchange (ETDEWEB)

The current status of non-silicon photovoltaic solar cells is discussed including the identification of current technical and economic issues and future research directions for potential high efficiency low cost technologies. This review covers such advanced materials as CdS/Cu/sub 2/S, CdS/CuInSe/sub 2/, and GaAs homojunction and heterojunction devices; such emerging materials as InP, Zn/sub 3/P/sub 2/ and CdTe; and liquid junction electrochemical photovoltaic cells. An attempt is made to compare the current relative status of these various technologies and to indicate their near term potential where possible. 105 refs.

1980-01-01

469

Observation of strain-enhanced electron-spin polarization in photoemission from InGaAs  

International Nuclear Information System (INIS)

Electron-spin polarization in excess of 70% has been observed in photoemission from a 0.1-#mu#m-thick epitaxial layer of In_xGa_1_-_xAs with x#approx#0.13 grown on a GaAs substrate. Under these conditions, the epitaxial layer is expected to be highly strained by the 0.9% lattice mismatch. The electron polarization and the quantum efficiency have been measured as a function of the excitation photon energy from 1.25 to 2.0 eV. A significant enhancement of the electron polarization occurs in the vicinity of 1.33 eV where the expected strain-induced level splitting permits optical excitation of a single-band transition.

470

Microscopic Origin of the Phenomenological Equilibrium ''Doping Limit Rule'' in n -Type III-V Semiconductors  

International Nuclear Information System (INIS)

The highest equilibrium free-carrier doping concentration possible in a given material is limited by the ''pinning energy'' which shows a remarkable universal alignment in each class of semiconductors. Our first-principles total energy calculations reveal that equilibrium n -type doping is ultimately limited by the spontaneous formation of close-shell acceptor defects: the 3- -charged cation vacancy in AlN, GaN, InP, and GaAs and the 1- -charged DX center in AlAs, AlP, and GaP. This explains the alignment of the pinning energies and predicts the maximum equilibrium doping levels in different materials. (c) 2000 The American Physical Society

2000-02-07

471

Materials aspects of multijunction solar cells  

Energy Technology Data Exchange (ETDEWEB)

Atomic layer epitaxy (ALE) was used to grow several components of the cascade solar cell structure in the AlGaAs/GaAs system. An ALE reactor was constructed for multiwafer growth with a growth rate of 0.6 {mu}m h{sup -1}. Device quality GaAs and Al{sub x}Ga{sub 1-x}As films were grown with p-type background carbon doping in the ranges 10{sup 16}-10{sup 19} cm{sup -3} and 10{sup 16}-10{sup 20} cm{sup -3} respectively. N-type films were achieved by SiH{sub 4} doping, producing carrier concentrations in the range 10{sup 16}-10{sup 18} cm{sup -3}. In addition, the potential applications of the ALE technique in the photovoltaic field are discussed. (orig.).

1991-05-01

472

Focused ion beam implantation induced site-selective growth of InAs quantum dots  

International Nuclear Information System (INIS)

The site-selective growth of InAs quantum dots (QDs) by a combined focused ion beam (FIB) and molecular beam epitaxy (MBE) process has been demonstrated. An array of FIB modified spots on MBE grown GaAs was fabricated. Thereafter, an in situ annealing step followed by InAs deposition was performed. The InAs QDs were preferentially formed in the holes generated by the FIB. The influences of ion dose, annealing parameters, and InAs amount were investigated. With optimized parameters, the authors observe more than 50% single dot occupancy per holes. Photoluminescence spectra confirm the good optical quality of the QDs.

2007-09-17

473

Dependence of impurity binding energy on nitrogen and indium concentrations for shallow donors in a GaInNAs/GaAs quantum well under intense laser field  

British Library Electronic Table of Contents (United Kingdom)

Within the framework of the effective-mass approximation, using a variational method, we have calculated the effect of intense laser radiation on the binding energy of the shallow-donor impurities in a Ga1- x In x N y As1- y /GaAs single quantum well for different nitrogen and indium mole concentrations. Our numerical results show that the binding energy strongly depends on the laser intensity and frequency (via the laser dressing parameter) and it also depends on the nitrogen and indium concentrations. Impurity binding energy under intense laser fields can be tuned by changing the nitrogen and indium mole fraction.

2011-01-01

474

Advances in the development of an AlGaAs/GaAs cascade solar cell using a patterned germanium tunnel interconnect  

Energy Technology Data Exchange (ETDEWEB)

In this paper, we discuss various aspects of the development of an inverted-grown AlGaAs/GaAs cascade solar cell incorporating a patterned germanium tunnel junction. Topics include the development of the Al{sub 0.37}Ga{sub 0.63}As top cell, the growth of the GaAs bottom cell over the patterned germanium tunnel junction, and a technique for selective removal of thin AlGaAs/GaAs heterostructures after lattice-matched growth on germanium substrates. The problems to be overcome for the achievement of around 30% efficiencies in the AlGaAs/GaAs cascade cell under concentrator applications are also discussed. (orig.).

1991-05-01

475

A model for Schottky-barrier solar cell analysis  

Science.gov (United States)

A general model for the analysis of metal-semiconductor solar cells is presented. The model takes into account the cell optical properties, carrier recombination effects, semiconductor minority-carrier properties, series resistance, cell thickness, and active surface area. Numerical methods are used to solve the appropriate continuity equations and hence compute the photocurrent density under AMO conditions. The operation of the model is demonstrated using p- and n-type Si and GaAs with Au being taken as the barrier metal. Calculations are presented showing the effect on solar energy conversion efficiency of surface recombination velocity, barrier height, minority-carrier lifetime, barrier metal thickness, collecting grid configuration, and cell thickness. A comparison of practical and computed data for the Au/n-GaAs system yields good agreement. (AIP)

1976-05-01

476

Self-filling and self-purging apparatus for detecting spontaneous radiation from substances in fluids  

Energy Technology Data Exchange (ETDEWEB)

Disclosed herein is a radiation detector providing for the in situ automatic sampling of fluids containing substances emitting radiation, especially Cerenkov radiation. The detector permits sampling within well casings and is self-purging such that no additional provisions must be established for the storage and disposal of contaminated fluids.

1993-01-01

477

Radon concentration measurements in the soil  

International Nuclear Information System (INIS)

Radon concentration measurement in the ground can be used for the prospecting for uranium and earthquake prediction. Some results of radon concentration measurement in the soil are presented here. The moisture condensation at the detector surface can affect on the detection efficiency. Due to this problem we tested a few filter papers on water permeability. The ratio of track densities on solid state nuclear track detector (SSNTD) in the open and the closed diffusion chamber is also determined. (author)

478

Proposed high-resolution vertex detector using superconductive thin strips  

Energy Technology Data Exchange (ETDEWEB)

The possibility of fabricating a superconductive vertex detector is discussed on the basis of a preliminary experiment. The experiment has shown that an indium strip 15 mm long, 20 ..mu..m wide and 0.1 ..mu..m thick is changed from the superconductive state to the normal state when struck by a single 5.4 MeV alpha particle.

1984-06-01

479

Portable real time neutron spectrometry II  

International Nuclear Information System (INIS)

We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.

2000-01-19

480

Portable real time neutron spectrometry  

International Nuclear Information System (INIS)

We describe the early stage of development of an engineering model portable, real-time neutron spectrometer. Several systems of two distinct detector types, a helium 3 gas filled proportional counter and a bulk silicon solid state detector, will be necessary to cover the energy range from thermal to 500 MeV. The advantages and disadvantages of using a moderator were investigated experimentally.

1999-01-22

481

Performance of the transition radiation detector in D{Phi}  

Energy Technology Data Exchange (ETDEWEB)

The transition radiation detector (TRD) for the D{Phi} experiment is currently in operation at Fermilab. Transition radiation production, which has been clearly observed in the collider data, makes the TRD a valuable tool to discriminate electrons and hadrons. We describe an algorithm based on the truncated energy, and illustrate its use for top signal and background. (authors). 7 refs., 6 figs., 2 tabs.

1994-12-31

482

Performance of a large Bragg-curve spectrometer  

Energy Technology Data Exchange (ETDEWEB)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/..delta..Z=80 have been achieved for eleastically scattered /sup 58/Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments.

1987-04-01

483

Performance of a large Bragg-curve spectrometer  

International Nuclear Information System (INIS)

A large Bragg-curve spectrometer has been constructed and tested. The detector has a cylindrical geometry and operates with a homogeneous electric field. Energy resolutions of <0.8% and Z resolutions of Z/#DELTA#Z=80 have been achieved for eleastically scattered "5"8Ni ions. These results demonstrate the suitability of this large solid-angle detector for use in a wide variety of heavy-ion scattering experiments. (orig.).

484

Near-Core and In-Core Neutron Radiation Monitors for Real Time Neutron Flux Monitoring and Reactor Power Level Measurements  

Energy Technology Data Exchange (ETDEWEB)

MPFDs are a new class of detectors that utilize properties from existing radiation detector designs. A majority of these characteristics come from fission chamber designs. These include radiation hardness, gamma-ray background insensitivity, and large signal output.

2006-06-12

485

Multi-spectral schottky barrier infrared radiation detection array  

Energy Technology Data Exchange (ETDEWEB)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

1983-12-27

486

Multi-spectral schottky barrier infrared radiation detection array  

International Nuclear Information System (INIS)

A multi-spectral Schottky barrier infrared detector array in which individual pixels of radiation from a remote radiating object are detected by two or more Schottky barrier infrared radiation detectors each having a different spectral response so as to provide a ''color'' discrimination for the array.

487

Interaction region layout of the VLEPP based photon linear collider with ultimate luminosity  

Energy Technology Data Exchange (ETDEWEB)

In the present paper, a possible interaction region layout of the VLEPP based Photon Linear Collider (PLC) with ultimate luminosity is discussed. In order to remove spent electron beams, the crab-crossing scheme is used. The detector is protected from produced pairs and secondary particles by means of the detector magnetic field and a shielding mask. ((orig.)).

1995-02-01

488

Gamma ray detecting device using dislocation-free crystal  

Energy Technology Data Exchange (ETDEWEB)

This patent describes a {gamma}-ray detector. It comprises: a dislocation-free single crystal having an input surface and a transmission surface at opposite ends thereof; an active shield surrounding the crystal and functioning as an anticoincidence counter; and {gamma}-ray detector means disposed adjacent the transmission surface of the crystal for receiving and detecting {gamma}-rays of a predetermined wavelength incident on the input surface of the crystal at a specific Bragg angle and transmitted through the crystal.

1991-04-30

489

First tests of "bulk" MICROMEGAS with resistive cathode mesh  

CERN Document Server

We present the first results from tests of a MICROMEGAS detector manufactured using the so-called "bulk" technology and having a resistive cathode mesh instead of the conventional metallic one. This detector operates as usual MICROMEGAS, but in the case of sparks, which may appear at high gas gains, the resistive mesh reduces their current and makes the sparks harmless. This approach could be complementary to the ongoing efforts of various groups to develop spark-protected MICROMEGAS with resistive anode planes.

2010-01-01

490

Explosives detection: the problem and prospects  

Energy Technology Data Exchange (ETDEWEB)

The history of explosives vapor detection includes almost every detection strategy known to man. Initial attempts to utilize these techniques were dismal failures. However, with the development of the Electron Capture Detector (ECD), the first promising detection of explosives vapors became possible. The present commercial explosives detectors detect the higher vapor pressure materials but not the whole spectrum. This paper describes the basic properties of explosives molecules and our research to utilize these properties for increased detection sensitivity.

1984-01-01

491

Direct gamma-spectrometry of surface activity with IGC-30 HPGe detector  

International Nuclear Information System (INIS)

The IGC-30 HPGe detector with MCA 'CANBERRA-10 PLUS' allows to determine surface contamination of areas of any type with a minimum error in radius 8-10 m, at a 'uniform' contamination. A modification of the CANBERRA hardware and software is described allowing determination of both the activity of a possible 'radioactive spot' and the activity of the whole observed surface. (author).

1993-12-02

492

Determination of reactor kinetic parameters in a two-core reactor  

Energy Technology Data Exchange (ETDEWEB)

The kinetic parameters, ..cap alpha.. the coupling coefficient and tau-bar the mean neutron transit time have been determined using a reactor oscillator on the coupled-core of the Queen Mary College research reactor. By using correlation techniques it has proved possible to use detectors small enough to be inserted in the fuel tanks. It is shown that the simplified Baldwin model with one-group diffusion theory is inadequate to describe the kinetic behaviour and the experimentally-determined parameters are dependent upon the positioning of the detectors.

1982-01-01

493

Detector questions for a gamma-gamma collider  

Energy Technology Data Exchange (ETDEWEB)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

1995-02-01

494

Detector questions for a gamma-gamma collider  

International Nuclear Information System (INIS)

The working group reviewed the main difficulties foreseen in doing physics at a gamma-gamma collider. They discussed the requirements for the detector, calculated some of the signal and background rates, compared methods of measuring luminosity, looked at how to get the laser beams in, investigated ways of sweeping aside the electrons and considered ways of disposing of the used beams. No overwhelming obstacles were found but important questions still need to be answered. ((orig.)).

495

Detection device for high explosives  

Energy Technology Data Exchange (ETDEWEB)

A portable fiber optic detector that senses the presence of specific target chemicals by electrostatically attracting the target chemical to an aromatic compound coating on an optical fiber. Attaching the target chemical to the coated fiber reduces the fluorescence so that a photon sensing detector records the reduced light level and activates an appropriate alarm or indicator.

1992-01-01

496

Ceramic inspection system  

Science.gov (United States)

A system for inspecting a ceramic component. The ceramic component is positioned on a first rotary table. The first rotary table rotates the ceramic component. Light is directed toward the first rotary table and the rotating ceramic component. A detector is located on a second rotary table. The second rotary table is operably connected to the first rotary table and the rotating ceramic component. The second rotary table is used to move the detector at an angle to the first rotary table and the rotating ceramic component.

2006-05-16

497

Applications of Bonner sphere detectors in neutron field dosimetry  

Energy Technology Data Exchange (ETDEWEB)

The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)

1983-09-01

498

An imaging. gamma. -ray detector with scatter rejection for beam position control in radiotherapy  

Energy Technology Data Exchange (ETDEWEB)

An imaging detector for {gamma}-rays ({approx equal}1 MeV) based on minicell MWPCs with converters and a position resolution of {Delta}x=0.5 mm has been developed and tested. Very high rate capability (>10{sup 8}/cm{sup 2} s) and a special readout for suppression of scattered radiation are implemented allowing to enhance the measured contrast. The relevant physical processes are discussed and first pictures are presented. (orig.).

1991-12-01

499

Advanced radiation detector development: Advanced semiconductor detector development: Development of a oom-temperature, gamma ray detector using gallium arsenide to develop an electrode detector  

Energy Technology Data Exchange (ETDEWEB)

The advanced detector development project at the University of Michigan has completed the first full year of its current funding. Our general goals are the development of radiation detectors and spectrometers that are capable of portable room temperature operation. Over the past 12 months, we have worked primarily in the development of semiconductor spectrometers with {open_quotes}single carrier{close_quotes} response that offer the promise of room temperature operation and good energy resolution in gamma ray spectroscopy. We have also begun a small scale effort at investigating the properties of a small non-spectroscopic detector system with directional characteristics that will allow identification of the approximate direction in which gamma rays are incident. These activities have made use of the extensive clean room facilities at the University of Michigan for semiconductor device fabrication, and also the radiation ...

1995-11-01

500

A solution for solid state detector and preamplifier protection, during HV application and removal transition periods  

International Nuclear Information System (INIS)

Surface barrier detectors may be damaged, because of microplasma breakdown, in rapid application of bias voltage. The high performance FETs of very low noise preamplifiers may also be damaged by rapid changes of the bias voltage. The electronic device described permits the gradual application and removal of the bias voltage, without any influence on the power supply specification. (Auth.).