WorldWideScience

Sample records for femoral intramedullary nailing

  1. Long-term functional outcome following intramedullary nailing of femoral shaft fractures

    NARCIS (Netherlands)

    el Moumni, Mostafa; Voogd, Emma Heather; ten Duis, Henk Jan; Wendt, Klaus Wilhelm

    Background: The management of femoral shaft fractures using intramedullary nailing is a popular method. The purpose of this study was to evaluate the long-term functional outcome after antegrade or retrograde intramedullary nailing of traumatic femoral shaft fractures. We further determined

  2. New Technique: A Novel Femoral Derotation Osteotomy for Malrotation following Intramedullary Nailing

    Directory of Open Access Journals (Sweden)

    S. Jagernauth

    2012-01-01

    Full Text Available A 19-year-old female patient sustained a closed spiral midshaft femoral fracture and subsequently underwent femoral intramedullary nail insertion. At followup she complained of difficulty in walking and was found to have a unilateral in-toeing gait. CT imaging revealed 30 degrees of internal rotation at the fracture site, which had healed. A circumferential osteotomy was performed distal to the united fracture site using a Gigli saw with the intramedullary femoral nail in situ. The static distal interlocking screws were removed and the malrotation was corrected. Two further static distal interlocking screws were inserted to secure the intramedullary nail in position. The osteotomy went on to union and her symptoms of pain, walking difficulty, and in-toeing resolved. Our paper is the first to describe a technique for derotation osteotomy following intramedullary malreduction that leaves the intramedullary nail in situ.

  3. ediatric femoral shaft fractures treated by flexible intramedullary nailing.

    Science.gov (United States)

    Kapil Mani, K C; Dirgha Raj, R C; Parimal, Acharya

    2015-01-01

    Nowadays pediatric femoral fractures are more commonly managed with operative treatment rather than conservative treatment because of more rapid recovery and avoidance of prolonged immobilization. Children between the ages of 5-13 years are treated either by traction plus hip spica and flexible/elastic stable retrograde intramedullary nail, or external fixators in the case of open fractures. The aim of this study is to evaluate the outcome of pediatric femoral shaft fractures treated by stainless steel flexible intramedullary nail in children between 5 and 13 years of age. There were 32 cases of femoral shaft fractures which were all fixed with stainless steel flexible intramedullary nail under fluoroscopy. Long leg cast was applied at the time of fixation. Partial weight bearing was started 2 weeks after surgery. Patients were evaluated in follow-up study to observe the alignment of fracture, infection, delayed union, nonunion, limb length discrepancy, motion of knee joint, and time to unite the fracture. We were able to follow up 28 out of 32 patients. The patients were 8.14 years of age on average. The mean hospital stay after operation was 4 days and fracture union time was 9.57 weeks. There were 3 cases of varus angulation, 2 cases of anterior angulation, and 4 cases of limb lengthening. Patients aged between 5 and 13 years treated with flexible intramedullary nail for closed femoral shaft fracture have rapid union and recovery, short rehabilitation period, less immobilization and psychological impact, and cost-effective.

  4. [Results of femoral lengthening over an intramedullary nail and external fixator].

    Science.gov (United States)

    Jasiewicz, Barbara; Kacki, Wojciech; Tesiorowski, Maciej; Potaczek, Tomasz

    2008-01-01

    Current techniques of operative limb lengthening usually are based on distraction osteogenesis. One of the techniques is limb lengthening over an intramedullary nail. The goal of this study is to evaluate the results of femoral lengthening over an intramedullary nail. Between 1999 and 200619 femoral "over nail" lengthenings were performed. There were 7 males and 12 females. Mean patients' age at surgery was 15.8 years, and mean initial femoral shortening was 5.1 cm. Operative technique consisted of one-stage implantation of intramedullary nail and external fixator. Ilizarov apparatus was used in 9 patients, monolateral fixator in 10 cases--ORTHOFIX in 9 patients, Wagner fixator--in 1 patient. Intramedullary nail was locked proximally with screws or Schanz pins from external fixator. After distraction phase, external fixator was removed and distal locking screws were applied. Evaluation criteria: obtained lengthening, time of external fixator, treatment time, healing index, external fixation index, range of motion in hip and knee joints and complications according to Paley. The mean lengthening was 4.6 cm, and mean distraction time was 66.6 days. Mean time of external fixation was 115.5 days, and external fixation index was 26.2 days for centimeter. Healing index was 36.9 days for centimeter. In cases with monolateral fixator, healing index did not differ with the whole group. During treatment 18 complications occurred, for a rate of 0.9 complication per segment. Lengthening over an intramedullary nail reduces the time of external fixator. Over nail femoral lengthening can prevent axis deviation following regenerate bending. Complication rate is similar to lengthenings with the classic Ilizarov technique. There are no differences in the treatment time in relation to the type of external fixator.

  5. Incidence of Avascular Necrosis of the Femoral Head After Intramedullary Nailing of Femoral Shaft Fractures

    Science.gov (United States)

    Kim, Ji Wan; Oh, Jong-Keon; Byun, Young-Soo; Shon, Oog-Jin; Park, Jai Hyung; Oh, Hyoung Keun; Shon, Hyun Chul; Park, Ki Chul; Kim, Jung Jae; Lim, Seung-Jae

    2016-01-01

    Abstract The goal of this study was to determine the incidence of avascular necrosis of the femoral head (AVNFH) after intramedullary nailing of femoral shaft fractures and to identify risk factors for developing AVNFH. We retrospectively reviewed all patients with femoral shaft fractures treated with antegrade intramedullary nailing at 10 institutions. Among the 703 patients enrolled, 161 patients were excluded leaving 542 patients in the study. Average age was 42.1 years with average follow-up of 26.3 months. Patient characteristics and fracture patterns as well as entry point of femoral nails were identified and the incidence of AVNFH was investigated. Patients were divided into 2 groups according to open versus closed physis, open versus closed fractures, and age (<20 versus ≥20 years). Overall incidence of AVNFH was 0.2% (1 of 542): the patient was 15-year-old boy. Of 25 patients with open physis, the incidence of AVNFH was 4%, whereas none of 517 patients with closed physis developed AVNFH (P < 0.001). The incidence of AVNFH in patients aged < 20 versus ≥20 years was 1.1% (1 of 93) and 0.0% (0 of 449), respectively (P = 0.172), which meant that the incidence of AVNFH was 0% in adult with femur shaft fracture. Of 61 patients with open fractures, the incidence of AVNFH was 0%. The number of cases with entry point at the trochanteric fossa or tip of the greater trochanter (GT) was 324 and 218, respectively, and the incidence of AVNFH was 0.3% and 0.0%, respectively (P = 0.412). In patients aged ≥20 years with isolated femoral shaft fracture, there was no case of AVNFH following antegrade intramedullary nailing regardless of the entry point. Therefore, our findings suggest that the risk of AVNFH following antegrade femoral nailing is extremely low in adult patients. PMID:26844518

  6. [Intramedullary nailing combined with cannulated screw in treating femoral condyles fractures].

    Science.gov (United States)

    Shen, Guo-Qing; Zhang, Hao; Long, Da-Fu; Li, Zheng-Wen; Tan, Ying-Dong

    2017-07-25

    To observe the clinical effects of retrograde intramedullary nailing and cannulated screws in the treatment of femoral condylar fracture. From June 2009 to June 2015, 13 patients with femoral condyles fracture were treated by retrograde intramedullary nailing and cannulated screws including 6 males and 7 females with an average age of 46.1 years old ranging from 16 to 76 years old. There were 10 cases of closed fractures, 3 cases of open fraetures. According to AO classification criteriam, 4 cases were type C1, 7 cases were type C2, 2 cases were type C3. Postoperative reduction of fracture and the knee joint function recovery were observed. All patients were followed up for 12 to 36 months with a mean of 24 months. X-ray examination showed that the union time of fracture was 18 to 24 weeks, 21 weeks on average. There were no cases of loosening, breakage of internal fixators and re-fracture. Hospital for Special Surgery(HSS) knee score was 90.07±4.99 at 1 year after the operation. The clinical efficacy for retrograde intramedullary nailing and cannulated screw for the treatment of femoral condyles fracture was excellent. It can improve the anatomical reattachment rate and reduce the complications and promote the knee functional recovery.

  7. Subtrochanteric femoral fracture during trochanteric nailing for the treatment of femoral shaft fracture.

    Science.gov (United States)

    Yun, Ho Hyun; Oh, Chi Hun; Yi, Ju Won

    2013-09-01

    We report on three cases of subtrochanteric femoral fractures during trochanteric intramedullary nailing for the treatment of femoral shaft fractures. Trochanteric intramedullary nails, which have a proximal lateral bend, are specifically designed for trochanteric insertion. When combined with the modified insertion technique, trochanteric intramedullary nails reduce iatrogenic fracture comminution and varus malalignment. We herein describe technical aspects of trochanteric intramedullary nailing for femoral shaft fractures to improve its application and prevent implant-derived complications.

  8. Subtrochanteric Femoral Fracture during Trochanteric Nailing for the Treatment of Femoral Shaft Fracture

    OpenAIRE

    Yun, Ho Hyun; Oh, Chi Hun; Yi, Ju Won

    2013-01-01

    We report on three cases of subtrochanteric femoral fractures during trochanteric intramedullary nailing for the treatment of femoral shaft fractures. Trochanteric intramedullary nails, which have a proximal lateral bend, are specifically designed for trochanteric insertion. When combined with the modified insertion technique, trochanteric intramedullary nails reduce iatrogenic fracture comminution and varus malalignment. We herein describe technical aspects of trochanteric intramedullary nai...

  9. Complications and Functional Recovery in Treatment of Femoral Shaft Fractures with Unreamed Intramedullary Nailing

    OpenAIRE

    Sadic, Sahmir; Custovic, Svemir; Smajic, Nedim; Fazlic, Mirsad; Vujadinovic, Aleksandar; Hrustic, Asmir; Jasarevic, Mahir

    2014-01-01

    ABSTRACT Introduction: Fracture of the femoral shaft is a common fracture encountered in orthopedic practice. In the 1939, K?ntscher introduced the concept of intramedullary nailing for stabilization of long bone fractures. Intramedullary nailing has revolutionized the treatment of fractures. Material and methods: The study included 37 male patients and 13 female patients, averaged 39?20,5 years (range, 16 to 76 years). Results and discussion: There were 31 left femurs and 21 right femurs fra...

  10. Flexible intramedullary nailing for femoral diaphyseal fractures in children

    Directory of Open Access Journals (Sweden)

    Rojan Tamrakar

    2017-12-01

    Full Text Available Background & Objectives: Although various treatment options are available for the treatment of femoral diaphyesal fractures in children, the titanium flexible nailing has gained popularity because it is safe, easy procedure with rapid recovery and high success rate. The aim of this study was to evaluate the outcome of titanium elastic nails in treating paediatric femoral diaphyesal fractures at Patan Hospital.Materials & Methods: There were 35 cases which were all fixed with titanium flexible intramedullary nail under image intensifier at the Patan hospital from January 2013 and December 2015. Patients were evaluated in follow-ups to observe the alignment of fracture, infection, delayed union, nonunion, limb length discrepancy, implant failure, range of movement of hip and knee joints, and time to unite the fracture. The final results were evaluated using criteria of titanium elastic nail (TEN outcome score described by Flynn et al.Results: The mean age of the patients was 8.51 years. Among 35 patients (22 boys and 13 girls, there were 19 mid-shaft fractures, nine proximal third fractures and seven distal third fractures. Fracture patterns were transverse (22, oblique (10, spiral (2, and comminuted (2. The mean time for fracture union was 8.17 weeks radiologically whereas 9.83 weeks clinically. According to TEN outcome score, excellent and good results were in 28 cases (80% and seven cases (20% respectively.Conclusion: Flexible titanium nailing is a safe and satisfactory treatment for diaphyseal femoral fractures in children, because it provides rapid recovery, short rehabilitation and immobilization as well as very high union rate with few complications.

  11. Femoral shaft fractures in children: elastic stable intramedullary nailing in 31 cases

    DEFF Research Database (Denmark)

    Houshian, Shirzad; Gøthgen, Charlotte Buch; Pedersen, Niels Wisbech

    2004-01-01

    We report our experience with elastic stable intramedullary titanium nailing (ESIN) of femoral shaft fractures in children. From 1998 to 2001, we treated 31 children (20 boys), median age 6 (4-11) years, with ESIN for 29 closed and 2 grade I open femoral shaft fractures. We reviewed 30 children...... clinically after median 1.5 (1-3) years. Their median hospital stay was 6 (2-20) days. All fractures were radiographically united at a median of 7 (5-9) weeks. The nails were removed in 29 children after a median of 22 (6-38) weeks postoperatively. At follow-up, we found a leg-length discrepancy up to 1 cm...

  12. "Push-past" reaming as a reduction aid with intramedullary nailing of metadiaphyseal and diaphyseal femoral shaft fractures.

    Science.gov (United States)

    Gary, Joshua L; Munz, John W; Burgess, Andrew R

    2014-06-01

    Eccentric reaming of cortical bone near a fracture site can introduce malalignment when an intramedullary nail is placed. The authors describe a technique of reaming metadiaphyseal and diaphyseal femur fractures in which maintaining reduction at the fracture site is not necessary to obtain an excellent alignment of long bone fractures after intramedullary nailing. They have found that central reaming proximal and distal to, but not at, the fracture site allows for excellent reduction of long bone fractures when the intramedullary nail is passed. The reamer is stopped just before the fracture site and then "pushed" across the fracture prior to resumption of reaming. The authors present "push-past" reaming as a technical trick to facilitate reduction of femoral fractures treated with intramedullary nails and a consecutive series of 18 cases in which excellent postoperative alignment was achieved. Copyright 2014, SLACK Incorporated.

  13. [Midterm follow-up results on Asian femoral intramedullary nail for the treatment of segmental and comminuted femoral fractures].

    Science.gov (United States)

    Li, Lang; Gao, Feng; Huang, Qi; Li, Qiang; Xie, Lin; Zhang, Bin

    2016-06-01

    To investigate midterm follow-up results on Asian femoral intramedullary nail in treating segmental and comminuted femoral fractures. Between June 2011 and October 2012,16 patients with segmental and comminuted femoral fractures were treated with minimally invasive reset and Asian femoral intramedullary nail under extension table. Among them, there were 10 males and 6 females aged from 21 to 49 years old with an average of 34.5 years old; the time from injury to operation ranged from 3 to 24 d with an average of 9.1 d. There were 6 cases were type C1,2 cases were type C2 and 8 cases were type C3 according to AO classification. X-ray of femoral segment at 3,6 and 12 months after operation were applied for evaluating fracture healing. Harris score of hip joint and HSS score of knee joint were used to evaluate postoperative function. All patients were followed up from 24 to 36 months with an average of 28.4 months. Operative time was from 88 to 112 min with an average of 90.7 min; blood loss ranged from 150 to 200 ml with an average of 188.75 ml; the time of fracture healing was from 5 to 9 months with an average of 5.4 months. All incision were healed at stage I. No loosening, breakage of internal fixation and displacement of fracture were occurred. There were no significant differences in Harris score of hip joint at 3, 6 and 12 months after operation (F = 0.07, P = 0.893 > 0.05), 10 cases obtained excellent results, 5 good and 1 moderate. There was no obvious meaning in HSS score of knee joint (F = 0.08,P = 0.876 > 0.05), 9 cases obtained excellent results, 6 good and 1 poor. Asian femoral intramedullary nail could treat segmental and comminuted femoral fractures by using variety of less invasive ways,which has advantages of less trauma, quick recovery of function and satisfied midterm following-up results. But long term following-up effects remains to be seen.

  14. Intramedullary nailing for the treatment of aseptic femoral shaft non-unions after plating failure: effectiveness and timing.

    Science.gov (United States)

    Megas, Panagiotis; Syggelos, Spyros A; Kontakis, Georgios; Giannakopoulos, Andreas; Skouteris, Georgios; Lambiris, Elias; Panagiotopoulos, Elias

    2009-07-01

    This retrospective, multicentre study aimed to evaluate reamed intramedullary nailing (IMN) for the treatment of 30 cases of aseptic femoral shaft non-union after plating failure. Following nailing, 29 non-unions had healed by a mean 7.93 months. In one case a hypertrophic non-union required renailing after 8 months, using a nail of greater diameter, and united within five further months. Healing times were not related to whether the fracture was open or closed, the type non-union or the type of fracture. The delay from the initial plating to intramedullary nailing had a statistically significant effect on healing time and final outcome. This treatment is cost effective and should be implemented as soon as the non-union is diagnosed.

  15. Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire.

    Science.gov (United States)

    Metikala, Sreenivasulu; Mohammed, Riazuddin

    2011-07-01

    Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described. This closed technique involves no additional equipment or instruments. Eight patients who underwent the described method were included in the study. The technique involves using a standard plain guide wire passed through the cannulated distal broken nail segment after extraction of the proximal nail fragment. The plain guide wire is then advanced distally into the knee joint carefully under fluoroscopy imaging. Over this wire, a 5-millimeter (mm) cannulated large drill bit is used to create a track up to the distal broken nail segment. Through the small knee wound, a ball-tipped guide wire is passed, smooth end first, till the ball engages the end of the nail. The guide wire is then extracted along with the broken nail through the proximal wound. The method was successfully used in all eight patients for removal of broken cannulated intramedullary nail from the femoral canal without any complications. All patients underwent exchange nailing with successful bone union in six months. None of the patients had any problems at the knee joint at the final follow-up. We report a technique for successful extraction of the distal fragment of broken femoral intramedullary nails without additional surgical approaches.

  16. Open grade III fractures of femoral shaft: Outcome after early reamed intramedullary nailing.

    Science.gov (United States)

    Singh, D; Garg, R; Bassi, J L; Tripathi, S K

    2011-09-01

    Open grade III fractures of femur are a challenging therapeutic problem as most of them are associated with multiple trauma. Method used for skeletal stabilization of these fractures should limit further soft tissue damage, bacterial spread and morbidity in addition to its ease of application, providing mechanical support and restoring normal alignment. Forty-six patients with open grade III fractures of femoral shaft were included in the study. There were 10 grade IIIA, 34 grade IIIB and two grade IIIC fractures that were treated with early reamed intramedullary nailing with adequate management of soft tissue. Patients were reviewed retrospectively. Mean time of union was 27 weeks. Infection rate was 4% and non-union rate was 9%. There were two cases (4%) with limb shortening. No case of angular or rotational deformity was noted. Early reamed intramedullary nailing for open grade III fractures of femoral shaft, after giving due respect to the soft tissue injury, gives satisfactory results with proper alignment, good range of motion, short rehabilitation period and low infection rate. Level IV. Retrospective therapeutic study. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  17. Shielding of the patient's gonads during intramedullary interlocking femoral nailing.

    Science.gov (United States)

    Kwong, L M; Johanson, P H; Zinar, D M; Lenihan, M R; Herman, M W

    1990-12-01

    Levels of exposure to radiation were recorded at sixty sites in fifteen patients during intramedullary interlocking femoral nailing. Radiation film dosimeters were placed at four gonadal sites on each subject. A standard male-gonad cup or a pelvic drape of 0.5-millimeter-thick lead-equivalent was put in place to shield the gonads. A second set of four dosimeters was placed external to the shield to approximate unprotected exposure. The total duration of the fluoroscopy averaged five minutes (range, thirty seconds to fourteen minutes). The total exposure to radiation external to the shield was 35 +/- 34 millirems at the male gonadal sites and 17 +/- 11 millirems at the female gonadal sites. With use of the gonadal shield, exposure to radiation was not measurable in thirteen of the fifteen patients. The differences between the exposures of the shielded and unshielded sites to radiation were statistically significant (p less than 0.001). The highest level of gonadal exposure was found with the treatment of proximal femoral fractures and with the use of statically locked nails. Regardless of the conditions, and for all types of fractures and locations, our results demonstrated that gonadal shielding is justified.

  18. Shielding of the patient's gonads during intramedullary interlocking femoral nailing

    International Nuclear Information System (INIS)

    Kwong, L.M.; Johanson, P.H.; Zinar, D.M.; Lenihan, M.R.; Herman, M.W.

    1990-01-01

    Levels of exposure to radiation were recorded at sixty sites in fifteen patients during intramedullary interlocking femoral nailing. Radiation film dosimeters were placed at four gonadal sites on each subject. A standard male-gonad cup or a pelvic drape of 0.5-millimeter-thick lead-equivalent was put in place to shield the gonads. A second set of four dosimeters was placed external to the shield to approximate unprotected exposure. The total duration of the fluoroscopy averaged five minutes (range, thirty seconds to fourteen minutes). The total exposure to radiation external to the shield was 35 +/- 34 millirems at the male gonadal sites and 17 +/- 11 millirems at the female gonadal sites. With use of the gonadal shield, exposure to radiation was not measurable in thirteen of the fifteen patients. The differences between the exposures of the shielded and unshielded sites to radiation were statistically significant (p less than 0.001). The highest level of gonadal exposure was found with the treatment of proximal femoral fractures and with the use of statically locked nails. Regardless of the conditions, and for all types of fractures and locations, our results demonstrated that gonadal shielding is justified

  19. Minimizing Leg Length Discrepancy After Intramedullary Nailing of Comminuted Femoral Shaft Fractures: A Quality Improvement Initiative Using the Scout Computed Tomography Scanogram.

    Science.gov (United States)

    Gheraibeh, Petra; Vaidya, Rahul; Hudson, Ian; Meehan, Robert; Tonnos, Frederick; Sethi, Anil

    2018-05-01

    To prevent leg length discrepancy (LLD) after locked femoral nailing in patients with comminuted femoral shaft fractures. Prospective consecutive case series aimed at quality improvement. Level 1 Trauma Center PATIENTS:: Ninety-eight consecutive patients with a comminuted femoral shaft fracture underwent statically locked intramedullary nailing, with a focused attempt at minimizing LLD during surgery. A computed tomography scanogram of both legs was performed on postoperative day 1 to assess for residual LLD. Patients were offered the option to have LLD >1.5 cm corrected before discharge. LLD >1.5 cm. Twenty-one patients (21.4%) were found to have an LLD >1.5 cm. An LLD >1.5 cm occurred in 10/55 (18%) antegrade nail patients and 11/43 (26%) retrograde nail patients (P = 0.27). No difference was noted based on the mechanism of injury, surgeon training and OTA/AO type B versus C injury. Ninety of 98 patients left with 1.5 cm after locked intramedullary nailing for a comminuted femoral shaft fracture without being informed and the option of early correction. We recommend using a full-length computed tomography scanogram after IM nailing of comminuted femur fractures to prevent iatrogenic LLD. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  20. Current indications for open Kuntscher nailing of femoral shaft ...

    African Journals Online (AJOL)

    Current indications for open Kuntscher nailing of femoral shaft fractures. A S Bajwa FCS(SA)ORTH. E Schnaid FCS(SA)ORTH. M E B Sweet MD PhD(rned). University of Witwatersrand, Johannesburg, South Africa. Key Words: Kuntscher nail, intramedullary nail, femoral fracture. We retrospectively reviewed 32 patients with.

  1. An evaluation of flexible intramedullary nail fixation in femoral shaft fractures in paediatric age group.

    Science.gov (United States)

    Kumar, Sanjay; Roy, Sandip Kumar; Jha, Amrish Kumar; Chatterjee, Debdutta; Banerjee, Debabrata; Garg, Anant Kumar

    2011-06-01

    Sixty-two femoral shaft fractures in 60 patients treated by elastic intramedullary nailing with mean age of the patients being 9.2 years (range 5 years to 12 years) and average follow-up of 15 months (range 7 months to 60 months) are evaluated. Twenty-eight fractures were fixed with titanium elastic nail while 34 fractures were fixed with Enders nail. There were 40 midshaft fractures, 18 proximal femoral and 4 were fractures of distal third. Fracture patterns were transverse in 35, short oblique in 14 cases and 13 were spiral fractures. Mean age of union in this series was 17 weeks (range 12 weeks to 28 weeks). Ten cases had complications, 5 had nail tip irritation, 3 varus or valgus malalignment and 2 had delayed union. In this series, we did not have any non-union, refracture, limb length discrepancy or any major infection. The result demonstrates 100% union rate irrespective of the age, weight and height of the patient. Regardless of the site of fracture and their pattern, it united every time with elastic nail fixation. We did not find and mismatch in the results of fractures stabilised with titanium elastic nail with that of elastic stainless steel nail.

  2. Evaluation of malrotation following intramedullary nailing in a femoral shaft fracture model: Can a 3D c-arm improve accuracy?

    Science.gov (United States)

    Ramme, Austin J; Egol, Jonathan; Chang, Gregory; Davidovitch, Roy I; Konda, Sanjit

    2017-07-01

    Difficulty determining anatomic rotation following intramedullary (IM) nailing of the femur continues to be problematic for surgeons. Clinical exam and fluoroscopic imaging of the hip and knee have been used to estimate femoral version, but are inaccurate. We hypothesize that 3D c-arm imaging can be used to accurately measure femoral version following IM nailing of femur fractures to prevent rotational malreduction. A midshaft osteotomy was created in a femur Sawbone to simulate a transverse diaphyseal fracture. An intramedullary (IM) nail was inserted into the Sawbone femur without locking screws or cephalomedullary fixation. A goniometer was used to simulate four femoral version situations after IM nailing: 20° retroversion, 0° version, 15° anteversion, and 30° anteversion. In each simulated position, 3D c-arm imaging and, for comparison purposes, perfect lateral radiographs of the knee and hip were performed. The femoral version of each simulated 3D and fluoroscopic case was measured and the results were tabulated. The measured version from the 3D c-arm images was 22.25° retroversion, 0.66° anteversion, 19.53° anteversion, and 25.15° anteversion for the simulated cases of 20° retroversion, 0° version, 15° anteversion, and 30° anteversion, respectively. The lateral fluoroscopic views were measured to be 9.66° retroversion, 12.12° anteversion, 20.91° anteversion, and 18.77° anteversion for the simulated cases, respectively. This study demonstrates the utility of a novel intraoperative method to evaluate femur rotational malreduction following IM nailing. The use of 3D c-arm imaging to measure femoral version offers accuracy and reproducibility. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. The efficacy of single-stage open intramedullary nailing of neglected femur fractures.

    Science.gov (United States)

    Boopalan, P R J V C; Sait, Azad; Jepegnanam, Thilak Samuel; Matthai, Thomas; Varghese, Viju Daniel

    2014-02-01

    Neglected femur fractures are not rare in the developing world. Treatment options include single-stage open reduction and intramedullary nailing, or open release, skeletal traction, and then second-stage open intramedullary nailing, with bone grafting. Single-stage procedures have the potential advantage of avoiding neurovascular complications secondary to acute lengthening, but they require a second operation, with potentially increased resource use and infection risk. We sought to determine the (1) likelihood of union, (2) complications and reoperations, and (3) functional results with single-stage open intramedullary nailing without bone grafting in patients with neglected femur fractures. Between January 2003 and December 2007, 17 consecutive patients presented to our practice with neglected femoral shaft fractures. All were treated with single-stage nailing without bone grafting. There were 15 men and two women with a median age of 27 years. The average time from fracture to treatment was 13 weeks (range, 4-44 weeks). Eleven patients underwent open nailing with interlocked nails and six were treated with cloverleaf Kuntscher nails. Patients were followed for a minimum of 6 months (mean, 33 months; range, 6-72 months). The mean preoperative ROM of the knee was 28° (range, 10°-150°) and femoral length discrepancy was 3.1 cm (range, 1-5 cm). All fractures united and the mean time to union was 16 weeks (range, 7-32 weeks). There were no neurologic complications secondary to acute lengthening. The mean postoperative ROM of the knee was 130° (range, 60°-150°). All patients were able to return to preinjury work. Sixteen patients regained their original femoral length. One-stage open intramedullary nailing of neglected femoral diaphyseal fractures without bone grafting was safe and effective, and obviated the need for a two-stage approach. Although the findings need to be replicated in larger numbers of patients, we believe this technique may be useful in

  4. Shielding of the patient's gonads during intramedullary interlocking femoral nailing

    Energy Technology Data Exchange (ETDEWEB)

    Kwong, L.M.; Johanson, P.H.; Zinar, D.M.; Lenihan, M.R.; Herman, M.W. (Harbor/Univ. of California, Los Angeles Medical Center, Torrance (USA))

    1990-12-01

    Levels of exposure to radiation were recorded at sixty sites in fifteen patients during intramedullary interlocking femoral nailing. Radiation film dosimeters were placed at four gonadal sites on each subject. A standard male-gonad cup or a pelvic drape of 0.5-millimeter-thick lead-equivalent was put in place to shield the gonads. A second set of four dosimeters was placed external to the shield to approximate unprotected exposure. The total duration of the fluoroscopy averaged five minutes (range, thirty seconds to fourteen minutes). The total exposure to radiation external to the shield was 35 +/- 34 millirems at the male gonadal sites and 17 +/- 11 millirems at the female gonadal sites. With use of the gonadal shield, exposure to radiation was not measurable in thirteen of the fifteen patients. The differences between the exposures of the shielded and unshielded sites to radiation were statistically significant (p less than 0.001). The highest level of gonadal exposure was found with the treatment of proximal femoral fractures and with the use of statically locked nails. Regardless of the conditions, and for all types of fractures and locations, our results demonstrated that gonadal shielding is justified.

  5. Complications and functional recovery in treatment of femoral shaft fractures with unreamed intramedullary nailing.

    Science.gov (United States)

    Sadic, Sahmir; Custovic, Svemir; Smajic, Nedim; Fazlic, Mirsad; Vujadinovic, Aleksandar; Hrustic, Asmir; Jasarevic, Mahir

    2014-01-01

    Fracture of the femoral shaft is a common fracture encountered in orthopedic practice. In the 1939, Küntscher introduced the concept of intramedullary nailing for stabilization of long bone fractures. Intramedullary nailing has revolutionized the treatment of fractures. The study included 37 male patients and 13 female patients, averaged 39 +/- 20.5 years (range, 16 to 76 years). There were 31 left femurs and 21 right femurs fractured. 46 fractures were the result of blunt trauma. Low energy trauma was the cause of fractures in six patients, of which five in elderly females. 49 fractures were closed. Healing time given in weeks was 19.36 +/- 6.1. The overall healing rate was 93.6%. There were three (6.25%) major complications nonunion. There were one (2%) delayed union, one (2%) rotational malunion and no infection. The shortening of 1 cm were in two patients. Antercurvatum of 10 degrees was found in one patient. There was no statistically significant reduction of a motion in the hip and knee (p knee extensors) muscle weakness (p fractures.

  6. Retained portion of latex glove during femoral nailing. Case report.

    Science.gov (United States)

    Sadat-Ali, M; Marwah, S; al-Habdan, I

    1996-11-01

    A case of retained glove during Kuntscher intramedullary nailing is described. An abscess around the glove could have lead to osteomyelitis. One need to be cautious feeling the top end of the nail while femoral nailing to avoid such a complication.

  7. [Treatment of multi-segment fracture of complex femoral shaft with instrument-assisted reduction combined with intramedullary interlocking nail fixation].

    Science.gov (United States)

    Fan, Ke-Jie; Chen, Ke; Ma, Wen-Long; Tian, Ke-Wei; Ye, Ye; Chen, Hong-Gan; Tang, Yan-Feng; Cai, Hong-Min

    2018-05-25

    To investigate the effect of minimally invasive mini-incision and instrumented reduction combined with interlocking intramedullary nailing in the treatment of patients with multi-segment fracture of complex femoral shaft. From January 2013 to January 2016, 32 patients with multiple fractures segments of femoral shaft were treated with instrumentation-assisted reduction combined with interlocking intramedullary nailing, including 22 males and 10 females with an average age of 45 years old ranging 17 to 68 years old. The time from injured to operation was 5 to 10 days with an average of 7 days. After admission, routine tibial tubercle or supracondylar bone traction was performed. The patient's general condition was evaluated, the operation time and intraoperative blood loss were recorded. According to Thorsen femoral fracture morphology evaluation criteria and Hohl knee function evaluation of postoperative efficacy, postoperative fracture healing, complications and postoperative recovery of limb function were observed. All patients were followed up for 6 to 24 months with an average of 12 months. The operative time ranged from 48 to 76 minutes with an average of 67 min. The intraoperative blood loss was 150 to 400 ml with an average of 220 ml. The surgical incisions all achieved grade A healing. The fractures reached the clinical standard of healing. The fracture healing time ranged from 4.2 to 10.8 months with an average of 5.7 months. There were no nonunion, incision infection and internal fixation fracture, failure and other complications. According to Thorsen femoral fracture morphology evaluation criteria, the result was excellent in 28 cases, good in 3 cases, fair in 1 case. According to Hohl knee function evaluation criteria, the result was excellent in 30 cases, good in 2 cases. Instrument-assisted reduction combined with interlocking intramedullary nail fixation is a safe and effective method for the treatment of complex femoral shaft fractures. It has

  8. Comparison of our self-designed rotary self-locking intramedullary nail and interlocking intramedullary nail in the treatment of long bone fractures.

    Science.gov (United States)

    Liu, Bailian; Xiong, Ying; Deng, Hong; Gu, Shao; Jia, Fu; Li, Qunhui; Wang, Daxing; Gan, Xuewen; Liu, Wei

    2014-07-21

    The purpose of this study is to compare the clinical effects of our self-designed rotary self-locking intramedullary nail (RSIN) and interlocking intramedullary nail (IIN) for long bone fractures. A retrospective study was performed in 1,704 patients who suffered bone fractures and underwent RSIN or IIN operation in our hospital between March 1999 and March 2013, including 494 with femoral fractures, 572 with humeral fractures, and 638 with tibial fractures. Among them, 634 patients were followed up for more than 1 year. The operative time, intraoperative blood loss, postoperative complications, healing rate, and the excellent and good rate of functional recovery were compared between two groups. Compared with IIN group, RSIN group exhibited significantly shorter operative time and less intraoperative blood loss no matter for humeral, femoral, or tibial fractures (all p fractures (both p fracture. In IIN group, nail breakage or loosening occurred in 7 patients with femoral fractures and 16 patients with tibial fractures, radial nerve injury was observed in 8 patients with humeral fractures, and incision infection was present in 2 patients with humeral fractures and 1 patient with femoral fracture. The complication rate of IIN group was significantly higher than that of RSIN group (p knee, and ankle joint functional recovery between RSIN group and IIN group. RSIN may be a reliable and practical alternative method for the treatment of long bone fractures.

  9. Effectiveness of plate augmentation for femoral shaft nonunion after nailing

    Directory of Open Access Journals (Sweden)

    Chin-Jung Lin

    2012-08-01

    Conclusion: Plate augmentation with retention of the nail with autologous bone grafting may be an effective and reliable alternative in treating nonunion of the femoral shaft fracture after open reduction and internal fixation with intramedullary nail.

  10. Clinical Outcomes after Open Locked Intramedullary Nailing of ...

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... joint stiffness due to prolonged immobilization.[8,9] Open reduction and internal fixation have reduced some of these complications by enabling early mobilization of the patient after surgery. The gold standard for treating closed femoral shaft fractures currently is closed locked intramedullary nailing.[10-13] ...

  11. Mating of a PROSTALAC spacer with an intramedullary nail for reconstruction of an infected interprosthetic femoral shaft fracture: a case report.

    Science.gov (United States)

    Kamath, Atul F; Austin, Daniel; Lee, Gwo-Chin

    2012-08-01

    Reconstruction for concurrent infection of an ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is a challenge. We report a 2-stage reconstruction of a THA for chronic infection of both the THA and TKA with severe femoral bone loss secondary to interprosthetic fractures. The reconstruction involved using a custom-made, temporary, antibiotic-impregnated PROSTALAC spacer mated with an intramedullary nail. The acetabulum was then exposed and the necrotic cartilage was removed and curetted. The acetabulum was reamed to accept a PROSTALAC acetabular shell. The shell was cemented into the acetabulum with antibiotic cement. The custom-made spacer was then inserted distally first into the tibia. The distal end of the intramedullary nail was interlocked with a bicortical bolt to minimise nail rotation. Antibiotic-impregnated cement was moulded around the nail and spacer. The proximal end of the spacer was then reduced into the acetabular socket, and the joint was irrigated and the wound closed. A customised abduction brace was fitted, and partial weight bearing was allowed. Sufficient leg length, soft-tissue tension, and range of hip motion were restored, and a total femur and constrained liner was re-implanted 4 months later. Mating of an intramedullary nail with a PROSTALAC spacer is a viable reconstructive option.

  12. Carbon fiber intramedullary nails reduce artifact in postoperative advanced imaging

    International Nuclear Information System (INIS)

    Zimel, Melissa N.; Hwang, Sinchun; Riedel, Elyn R.; Healey, John H.

    2015-01-01

    This study assessed whether radiolucent carbon fiber reinforced-polyetheretherketone (CFR-PEEK) intramedullary nails decreased hardware artifact on magnetic resonance imaging (MRI) and computed tomography (CT) in vitro and in an oncologic patient population. In vitro and clinical evaluations were done. A qualitative assessment of metal artifact was performed using CFR-PEEK and titanium nail MRI phantoms. Eight patients with a femoral or tibial prophylactic CFR-PEEK nail were retrospectively identified. All patients had postoperative surveillance imaging by MRI, CT, and were followed for a median 20 months (range, 12-28 months). CFR-PEEK images were compared to images from a comparative group of patients with titanium femoral intramedullary nails who had a postoperative MRI or CT. A musculoskeletal-trained radiologist graded visualization of the cortex, corticomedullary junction, and bone-muscle interface, on T1-weighted (T1W), STIR, and contrast-enhanced T1-weighted fat-saturated (T1W FS) sequences of both groups with a five-point scale, performing independent reviews 4 months apart. Statistical analysis used the Wilcoxon rank-sum test and a weighted kappa. Substantially less MRI signal loss occurred in the CFR-PEEK phantom than in the titanium phantom simulation, particularly as the angle increased with respect to direction of the static magnetic field. CFR-PEEK nails had less MRI artifact than titanium nails on scored T1W, STIR, and contrast-enhanced T1W FS MRI sequences (p ≤ 0.03). The mean weighted kappa was 0.64, showing excellent intraobserver reliability between readings. CFR-PEEK intramedullary nail fixation is a superior alternative to minimize implant artifact on MRI or CT imaging for patients requiring long bone fixation. (orig.)

  13. Carbon fiber intramedullary nails reduce artifact in postoperative advanced imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zimel, Melissa N. [Memorial Sloan Kettering Cancer Center, Orthopaedic Surgery Service, Department of Surgery, New York, NY (United States); Hwang, Sinchun [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Riedel, Elyn R. [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Healey, John H. [Memorial Sloan Kettering Cancer Center, Orthopaedic Surgery Service, Department of Surgery, New York, NY (United States); Weill Medical College of Cornell University, Department of Orthopaedic Surgery, New York, NY (United States)

    2015-09-15

    This study assessed whether radiolucent carbon fiber reinforced-polyetheretherketone (CFR-PEEK) intramedullary nails decreased hardware artifact on magnetic resonance imaging (MRI) and computed tomography (CT) in vitro and in an oncologic patient population. In vitro and clinical evaluations were done. A qualitative assessment of metal artifact was performed using CFR-PEEK and titanium nail MRI phantoms. Eight patients with a femoral or tibial prophylactic CFR-PEEK nail were retrospectively identified. All patients had postoperative surveillance imaging by MRI, CT, and were followed for a median 20 months (range, 12-28 months). CFR-PEEK images were compared to images from a comparative group of patients with titanium femoral intramedullary nails who had a postoperative MRI or CT. A musculoskeletal-trained radiologist graded visualization of the cortex, corticomedullary junction, and bone-muscle interface, on T1-weighted (T1W), STIR, and contrast-enhanced T1-weighted fat-saturated (T1W FS) sequences of both groups with a five-point scale, performing independent reviews 4 months apart. Statistical analysis used the Wilcoxon rank-sum test and a weighted kappa. Substantially less MRI signal loss occurred in the CFR-PEEK phantom than in the titanium phantom simulation, particularly as the angle increased with respect to direction of the static magnetic field. CFR-PEEK nails had less MRI artifact than titanium nails on scored T1W, STIR, and contrast-enhanced T1W FS MRI sequences (p ≤ 0.03). The mean weighted kappa was 0.64, showing excellent intraobserver reliability between readings. CFR-PEEK intramedullary nail fixation is a superior alternative to minimize implant artifact on MRI or CT imaging for patients requiring long bone fixation. (orig.)

  14. COMPARATIVE STUDY OF KUNTSCHER’S NAIL VS. INTERLOCKING NAILING FOR FEMORAL ISTHMUS FRACTURES

    Directory of Open Access Journals (Sweden)

    Rajeev Kumar Roy

    2017-05-01

    Full Text Available BACKGROUND Interlocking intramedullary nailing is suitable for comminuted femoral isthmus fractures, but for non-comminuted fractures its benefit over unlocked nailing is debatable. This study was undertaken to compare outcomes of interlocking nailing versus k-nail in such fractures. MATERIALS AND METHODS 40 cases of noncomminuted femoral isthmus fractures treated with interlocking nailing and K-nail from April 1, 2015, to December 1, 2016, were reviewed. Radiological and clinical union rates, bony alignment, complication and knee function were investigated. RESULTS There was no statistical significant difference with regard to union rate, implant failure, infection and fracture alignment in both study groups. Open fixation with K-nail is technically less demanding and requires less operating time; additionally, there is no exposure to radiation and cost of the implant is cheaper. CONCLUSION We therefore conclude that unlocked nailing is still useful for the management of noncomminuted isthmus fractures of the femur.

  15. The stability of a hip fracture determines the fatigue of an intramedullary nail.

    Science.gov (United States)

    Eberle, S; Bauer, C; Gerber, C; von Oldenburg, G; Augat, P

    2010-01-01

    The purpose of this study was to address the question of how the stability of a proximal hip fracture determines the fatigue and failure mechanism of an intramedullary implant. To answer this question, mechanical experiments and finite element simulations with two different loading scenarios were conducted. The two load scenarios differed in the mechanical support of the fracture by an artificial bone sleeve, representing the femoral head and neck. The experiments confirmed that an intramedullary nail fails at a lower load in an unstable fracture situation in the proximal femur than in a stable fracture. The nails with an unstable support failed at a load 28 per cent lower than the nails with a stable support by the femoral neck. Hence, the mechanical support of a fracture is crucial to the fatigue failure of an implant. The simulation showed why the fatigue fracture of the nail starts at the aperture of the lag screw. It is the location of the highest von Mises stress, which is the failure criterion for ductile materials.

  16. Humeral Shaft Fracture: Intramedullary Nailing.

    Science.gov (United States)

    Konda, Sanjit R; Saleh, Hesham; Fisher, Nina; Egol, Kenneth A

    2017-08-01

    This video demonstrates the technique of intramedullary nailing for a humeral shaft fracture. The patient is a 30-year-old man who sustained a gunshot wound to his right arm. The patient was indicated for humeral nailing given the comminuted nature of the diaphysis and to allow for minimal skin incisions. Other relative indications include soft-tissue compromise about the arm precluding a large surgical exposure. This video presents a case of a comminuted humeral shaft fracture treated with an intramedullary nail. Anatomic reduction and stable fixation was obtained with this technique. This case demonstrates a soft-tissue sparing technique of humeral shaft fixation using a humeral intramedullary nail. The technique is easy to perform and has significant benefits in minimizing surgical exposure, decreasing operative time, and decreasing blood loss. In the correct clinical setting, humeral nailing provides an expeditious form of fixation that restores length, alignment, and rotation of the fracture humeral diaphysis.

  17. Training effect of using Touch Surgery for intramedullary femoral nailing.

    Science.gov (United States)

    Sugand, Kapil; Mawkin, Mala; Gupte, Chinmay

    2016-02-01

    Simulation in orthopaedic training is becoming increasingly popular and has been widely used in formal curricula. However, these resources are expensive and not easily accessible to every trainee. Other means of disseminating surgical education through virtual reality (VR) multimedia can act as useful adjunct to traditional methods of teaching. One validated VR platform is Touch Surgery, a cognitive task simulation and rehearsal app. The primary objective of this study was to identify the training effect of Touch Surgery intramedullary femoral nailing (IFN) modules using objective performance metrics over six consecutive attempts. Secondary objectives consisted of validated multiple choice questions (MCQ) testing before the first (pre) and after the sixth (post) attempts. 27 medical undergraduates were recruited to complete the decision-making process six consecutive times for four modules on the procedural steps of IFN. The modules consisted of (i) preparing the patient and equipment, (ii) femoral canal preparation, (iii) nail insertion and proximal locking, and (iv) distal locking and closure. Real-time objective performance metrics were obtained, stored electronically and analysed using the median and Bonett-Price 95% confidence intervals from the participants' attempts to assess training effect. Significance was calculated using the Mann-Whitney U test for independent data whilst the Wilcoxon signed ranked test was used for paired data. Significance was set as 2-tailed p-value <0.05. Median performance scores per attempt for all four modules demonstrated a significant improvement ranging from 58 to 115%. Scoring variability and distribution was reduced and more predictable per attempt. Logarithmic learning curves elicited strong positive correlations between the number of attempts and scoring. Mean scores for pre and post-study MCQs tests significantly improved from 83 to 94% in all modules. IFN modules on Touch Surgery app demonstrated a significant training

  18. Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail.

    NARCIS (Netherlands)

    Schipper, I.B.; Steyerberg, E.W.; Castelein, R.M.; Heijden, F.H. van der; Hoed, P.T. den; Kerver, A.J.; Vugt, A.B. van

    2004-01-01

    The proximal femoral nail (PFN) is a recently introduced intramedullary system, designed to improve treatment of unstable trochanteric fractures of the hip. In a multicentre prospective clinical study, the intra-operative use, complications and outcome of treatment using the PFN (n = 211) were

  19. Occurrence of secondary fracture around intramedullary nails used for trochanteric hip fractures: a systematic review of 13,568 patients.

    Science.gov (United States)

    Norris, Rory; Bhattacharjee, Dhritiman; Parker, Martyn J

    2012-06-01

    A sliding hip screw (SHS) is currently the treatment of choice for trochanteric hip fractures, largely due to the low incidence of complications. An alternative treatment is the use of intramedullary proximal femoral nails. Unfortunately these implants have been associated with a risk of later fracture around the implant. The aim of this study was to see if any improvements have been made to the current intramedullary nails, to reduce the incidence of secondary fracture around the distal tip of the nail. We analysed data related to 13,568 patients from 89 studies, focusing on the incidence of post operative secondary femoral shaft fracture following the use of intramedullary nails in the fixation of trochanteric hip fractures. The overall reported incidence of secondary fracture around the nail was 1.7%. The incidence of fracture has reduced in the 3rd generation Gamma nails when compared to the older Gamma nail (1.7% versus 2.6%, p value 0.03). However, the incidence of secondary fracture in the 3rd generation Gamma nails is still significantly higher than the other brands of short nail (1.7% versus 0.7%, p value 0.0005). Long nails had a slight tendency towards a lower risk of fracture although the difference was not statistically significant (1.1% versus 1.7%, p value 0.28). There was a significantly lower risk of fracture for those nails with a biaxial fixation as opposed to uniaxial fixation (0.6% versus 1.9%, p value fracture around a proximal femoral nail is one of the most significant of fracture healing complications, and this study suggests that continuing design changes to this method of fixation has reduced the risk of this complication occurring. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Modification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model - results of biomechanical testing and a prospective clinical study.

    Science.gov (United States)

    Kaiser, Martin M; Stratmann, Christine; Zachert, Gregor; Schulze-Hessing, Maaike; Gros, Nina; Eggert, Rebecca; Rapp, Marion

    2014-01-08

    Elastic stable intramedullary nailing (ESIN) is the standard treatment for displaced diaphyseal femoral fractures in children. However, high complication rates (10-50%) are reported in complex fractures. This biomechanical study compares the stiffness with a 3rd nail implanted to that in the classical 2C-shaped configuration and presents the application into clinical practice. For each of the 3 configurations of ESIN-osteosynthesis with titanium nails eight composite femoral grafts (Sawbones®) with an identical spiral fracture were used: 2C configuration (2C-shaped nails, 2 × 3.5 mm), 3CM configuration (3rd nail from medial) and 3CL configuration (3rd nail from lateral). Each group underwent biomechanical testing in 4-point bending, internal/external rotation and axial compression. 2C and 3CM configurations showed no significant differences in this spiroid type fracture model. 3CL had a significantly higher stiffness during anterior-posterior bending, internal rotation and 9° compression than 2C, and was stiffer in the lateral-medial direction than 3CM. The 3CL was less stable during p-a bending and external rotation than both the others. As biomechanical testing showed a higher stability for the 3CL configuration in two (a-p corresponding to recurvation and 9° compression to shortening) of three directions associated with the most important clinical problems, we added a 3rd nail in ESIN-osteosynthesis for femoral fractures. 11 boys and 6 girls (2.5-15 years) were treated with modified ESIN of whom 12 were '3CL'; due to the individual character of the fractures 4 patients were treated with '3CM' (third nail from medial) and as an exception 1 adolescent with 4 nails and one boy with plate osteosynthesis. No additional stabilizations or re-operations were necessary. All patients achieved full points in the Harris-Score at follow-up; no limb length discrepancy occurred. The 3CL configuration provided a significantly higher stiffness than 2C and 3CM configurations

  1. Femoral Medialization, Fixation Failures, and Functional Outcome in Trochanteric Hip Fractures Treated With Either a Sliding Hip Screw or an Intramedullary Nail From Within a Randomized Trial.

    Science.gov (United States)

    Bretherton, Christopher P; Parker, Martyn J

    2016-12-01

    The aim of this study was to determine if femoral medialization influences residual pain and mobility and to determine if fixation method or fracture pattern influences the tendency to medialize. This study used data from within a randomized controlled trial. Peterborough City Hospital, UK. Eight hundred forty-four patients presenting with a trochanteric hip fracture were randomized. Five hundred thirty-eight were available for 1-year follow-up. Fractures were classified according to OTA/AO classification as 31 A1, A2, and A3. Randomized to fixation with a Targon proximal femoral nail or sliding hip screw (SHS). Femoral medialization was calculated from follow-up x-rays at a minimum of 28 days post-fixation. Pain and mobility scores were assessed at 1 year by an independent blinded observer. Fixation failure and revision procedures were assessed at a minimum of 1 year from injury. Patients with >50% medialization had worse pain (P = 0.012) and mobility scores (P = 0.013) at 1 year. They also had more fracture healing complications (P = 0.021) and required more revision procedures (P = 0.014). Fractures treated with SHS were more likely to medialize >50% compared with intramedullary nail (P fractures were more likely to medialize, and A3 fractures were more likely to undergo >50% medialization (P fractures treated with SHS to undergo femoral medialization and correlates this with worse functional outcomes. It supports the use of intramedullary nails for A3 fractures, which have a significant tendency to medialize. Prognostic level II. See Instructions for Authors for a complete description of levels of evidence.

  2. Staged protocol for the treatment of chronic femoral shaft osteomyelitis with Ilizarov's technique followed by the use of intramedullary locked nail.

    Science.gov (United States)

    Chou, Po-Hsin; Lin, Hsi-Hsien; Su, Yu-Pin; Chiang, Chao-Ching; Chang, Ming-Chau; Chen, Chuan-Mu

    2017-06-01

    Infected nonunion of the femoral shaft is uncommon, and usually presents with challenging therapeutic and reconstructive problems. There are still controversies over treating infected nonunion of the femoral shaft. The purposes of this retrospective study were to review the treatment outcomes and describe a staged protocol for spontaneous wound healing. Six patients with chronic femoral shaft infected-nonunion from October 2002 to September 2010 were included in this retrospective study. Serial plain films and triple films of lower legs were performed to evaluate the alignment of the treated femoral shaft and bony union following our staged protocol of Ilizarov distraction osteogenesis and intramedullary nailing. An average bone defect of 7 cm was noted after staged osteotomy. Mean follow-up was 87.5 (range, 38-133) months. Union was achieved in all six patients, with an average external fixation time of 6.8 (range, 5-11) months. There was no reinfection. One complication of a 4-cm leg discrepancy was noted, with an initial shortening of 15 cm. The mean knee ranges of motion (ROM) before staged protocols and at final follow-up were 64.2±8.6 (range, 60-75)° and 53.3±9.3 (range, 40-65)°, respectively. The ROM at the knee joint statistically decreased following staged protocols. In the treatment of chronic femur osteomyelitis, the staged protocol of Ilizarov distraction osteogenesis followed by intramedullary nailing was safe and successful, and allowed for union, realignment, reorientation, and leg-length restoration. With regard to the soft tissue, this technique provides a unique type of reconstructive closure for infected wounds. It is suggested that the staged protocol is reliable in providing successful simultaneous reconstruction for bone and soft tissue defects without flap coverage. Copyright © 2017. Published by Elsevier Taiwan LLC.

  3. A biomechanical comparison of proximal femoral nails and locking proximal anatomic femoral plates in femoral fracture fixation A study on synthetic bones

    Directory of Open Access Journals (Sweden)

    Korhan Ozkan

    2015-01-01

    Conclusion: The proximal femoral intramedullary nail provides more stability and allows for earlier weight bearing than the locking plate when used for the treatment of unstable intertrochanteric fractures of the femur. Clinicians should be cautious for early weight bearing with locking plate for unstable intertrochanteric femur fractures.

  4. The impact of antegrade intramedullary nailing start site using the SIGN nail in proximal femoral fractures: A prospective cohort study.

    Science.gov (United States)

    Mustafa Diab, Mohamed; Wu, Hao-Hua; Eliezer, Edmund; Haonga, Billy; Morshed, Saam; Shearer, David W

    2018-02-01

    In many low and middle-income countries (LMICs) SIGN nail is commonly used for antegrade femoral intramedullary (IM) nailing, using a start site either at the tip of the greater trochanter or piriformis fossa. While a correct start site is considered an essential technical step; few studies have evaluated the impact of using an erroneous start site. This is particularly relevant in settings with limited access to fluoroscopy to aid in creating a nail entry point. The purpose of this study was to evaluate the impact of antegrade SIGN IM nailing start site on radiographic alignment and health-related quality of life. In this prospective cohort study, adult patients with proximal femur fractures (OTA 32, subtrochanteric zone) treated with antegrade IM SIGN nail at Muhimbili Orthopaedic Institute (MOI), Dar es Salaam, Tanzania were enrolled. Start site was determined on the immediate postoperative X-ray and was graded on a continuous scale based on distance of the IM nail center from the greater trochanteric tip. The primary outcome measurement was coronal alignment on the post-operative x-ray. The secondary outcomes were reoperation rates, RUST scores and EQ5D scores at one year follow-up. Seventy-nine patients were enrolled. 50 of them (63.3%) had complete data at 1year and were included in the final data analysis. Of the fifty patients, nine (18%) had IM nails placed laterally, 26 (52%) medially and 15 (30%) directly over the tip of the greater trochanter. Compared to a start site at the tip or medial to the greater trochanter, a lateral start site was 9 times more likely to result in a varus malalignment (95% CI: 1.42-57.70, p=0.021). Lateral start site was associated with varus malalignment. Although lateral start site was not significantly associated with reoperation, varus deformity was associated with higher reoperation rates. Surgeons should consider avoiding a start site lateral to the tip of the greater trochanter or allow the nail to rotate to avoid

  5. Outcomes following femoral lengthening: An initial comparison of the Precice intramedullary lengthening nail and the LRS external fixator monorail system.

    Science.gov (United States)

    Laubscher, M; Mitchell, C; Timms, A; Goodier, D; Calder, P

    2016-10-01

    Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages. We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared. In 20 cases (15 patients) the Precice lengthening nail was used and in 13 cases (seven patients) the LRS external fixator system. The desired length was achieved in all cases in the Precice group and in 12 of 13 cases in the LRS group. The mean healing index was 31.3 days/cm in the Precice and 47.1 days/cm in the LRS group (p < 0.001). This was associated with an earlier ability to bear full weight without aids in the Precice group. There were more complications with LRS lengthening, including pin site infections and regenerate deformity. Implant tolerance and the patients' perception of the cosmetic result were better with the Precice treatment. Femoral lengthening with the Precice femoral nail achieved excellent functional results with fewer complications and greater patient satisfaction when compared with the LRS system in our patients. Cite this article: Bone Joint J 2016;98-B:1382-8. ©2016 The British Editorial Society of Bone & Joint Surgery.

  6. Should the tip-apex distance (TAD) rule be modified for the proximal femoral nail antirotation (PFNA)? A retrospective study.

    Science.gov (United States)

    Nikoloski, Andrej N; Osbrough, Anthony L; Yates, Piers J

    2013-10-17

    Unstable proximal femoral fractures are common and challenging for the orthopaedic surgeon. Often, these are treated with intramedullary nails. The most common mode of failure of any device to treat these fractures is cut-out. The Synthes proximal femoral nail antirotation (PFNA) is unique because it is the only proximal femoral intramedullary nail which employs a helical blade in lieu of a lag screw. The optimal tip-apex distance is 25 mm or less for a dynamic hip screw. The optimal blade tip placement is not known for the PFNA. The aim of this study is to determine if the traditional tip-apex distance rule (TAD) less than 20 mm. There was no cut-out in cases where the TAD was from 20-30 mm. There were three implant-related failures (nail fracture, missed nail and loose locking screw), four implant-related femoral fractures, two non-unions, two delayed unions and one loss of reduction. The PFNA is a suitable fixation device for the treatment of unstable proximal femoral fractures. There were still a relatively large number of cut-outs, and the tip-apex distance in the failures showed a bimodal distribution, not like previously demonstrated with dynamic hip screw. We propose that the helical blade behaves differently to a screw, and placement too close to the subchondral bone may lead to penetration through the head.

  7. Intramedullary Mg2Ag nails augment callus formation during fracture healing in mice.

    Science.gov (United States)

    Jähn, Katharina; Saito, Hiroaki; Taipaleenmäki, Hanna; Gasser, Andreas; Hort, Norbert; Feyerabend, Frank; Schlüter, Hartmut; Rueger, Johannes M; Lehmann, Wolfgang; Willumeit-Römer, Regine; Hesse, Eric

    2016-05-01

    Intramedullary stabilization is frequently used to treat long bone fractures. Implants usually remain unless complications arise. Since implant removal can become technically very challenging with the potential to cause further tissue damage, biodegradable materials are emerging as alternative options. Magnesium (Mg)-based biodegradable implants have a controllable degradation rate and good tissue compatibility, which makes them attractive for musculoskeletal research. Here we report for the first time the implantation of intramedullary nails made of an Mg alloy containing 2% silver (Mg2Ag) into intact and fractured femora of mice. Prior in vitro analyses revealed an inhibitory effect of Mg2Ag degradation products on osteoclast differentiation and function with no impair of osteoblast function. In vivo, Mg2Ag implants degraded under non-fracture and fracture conditions within 210days and 133days, respectively. During fracture repair, osteoblast function and subsequent bone formation were enhanced, while osteoclast activity and bone resorption were decreased, leading to an augmented callus formation. We observed a widening of the femoral shaft under steady state and regenerating conditions, which was at least in part due to an uncoupled bone remodeling. However, Mg2Ag implants did not cause any systemic adverse effects. These data suggest that Mg2Ag implants might be promising for intramedullary fixation of long bone fractures, a novel concept that has to be further investigated in future studies. Biodegradable implants are promising alternatives to standard steel or titanium implants to avoid implant removal after fracture healing. We therefore developed an intramedullary nail using a novel biodegradable magnesium-silver-alloy (Mg2Ag) and investigated the in vitro and in vivo effects of the implants on bone remodeling under steady state and fracture healing conditions in mice. Our results demonstrate that intramedullary Mg2Ag nails degrade in vivo over time without

  8. The effect of retained intramedullary nails on tibial bone mineral density.

    Science.gov (United States)

    Allen, J C; Lindsey, R W; Hipp, J A; Gugala, Z; Rianon, N; LeBlanc, A

    2008-07-01

    Intramedullary nailing has become a standard treatment for adult tibial shaft fractures. Retained intramedullary nails have been associated with stress shielding, although their long-term effect on decreasing tibial bone mineral density is currently unclear. The purpose of this study was to determine if retained tibial intramedullary nails decrease tibial mineral density in patients with successfully treated fractures. Patients treated with statically locked intramedullary nails for isolated, unilateral tibia shaft fractures were studied. Inclusion required that fracture had healed radiographically and that the patient returned to the pre-injury activity level. Data on patient demographic, fracture type, surgical technique, implant, and post-operative functional status were tabulated. Dual energy X-ray absorptiometry was used to measure bone mineral density in selected regions of the affected tibia and the contralateral intact tibia. Image reconstruction software was employed to ensure symmetry of the studied regions. Twenty patients (mean age 43; range 22-77 years) were studied at a mean of 29 months (range 5-60 months) following intramedullary nailing. There was statistically significant reduction of mean bone mineral density in tibiae with retained intramedullary nails (1.02 g/cm(2) versus 1.06 g/cm(2); P=0.04). A significantly greater decrease in bone mineral density was detected in the reamed versus non-reamed tibiae (-7% versus +6%, respectively; P<0.05). The present study demonstrates a small, but statistically significant overall bone mineral density decrease in healed tibiae with retained nails. Intramedullary reaming appears to be a factor potentiating the reduction of tibia bone mineral density in long-term nail retention.

  9. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

    OpenAIRE

    Mustafa Seyhan; Olcay Guler; Mahir Mahirogullari; Ferdi Donmez; Arel Gereli; Serhat Mutlu

    2018-01-01

    Objectives: Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of ...

  10. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

    OpenAIRE

    Seyhan, Mustafa; Guler, Olcay; Mahirogullari, Mahir; Donmez, Ferdi; Gereli, Arel; Mutlu, Serhat

    2018-01-01

    Objectives Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of t...

  11. Trochanteric entry femoral nails yield better femoral version and lower revision rates-A large cohort multivariate regression analysis.

    Science.gov (United States)

    Yoon, Richard S; Gage, Mark J; Galos, David K; Donegan, Derek J; Liporace, Frank A

    2017-06-01

    Intramedullary nailing (IMN) has become the standard of care for the treatment of most femoral shaft fractures. Different IMN options include trochanteric and piriformis entry as well as retrograde nails, which may result in varying degrees of femoral rotation. The objective of this study was to analyze postoperative femoral version between three types of nails and to delineate any significant differences in femoral version (DFV) and revision rates. Over a 10-year period, 417 patients underwent IMN of a diaphyseal femur fracture (AO/OTA 32A-C). Of these patients, 316 met inclusion criteria and obtained postoperative computed tomography (CT) scanograms to calculate femoral version and were thus included in the study. In this study, our main outcome measure was the difference in femoral version (DFV) between the uninjured limb and the injured limb. The effect of the following variables on DFV and revision rates were determined via univariate, multivariate, and ordinal regression analyses: gender, age, BMI, ethnicity, mechanism of injury, operative side, open fracture, and table type/position. Statistical significance was set at pregression analysis revealed that a lower BMI was significantly associated with a lower DFV (p=0.006). Controlling for possible covariables, multivariate analysis yielded a significantly lower DFV for trochanteric entry nails than piriformis or retrograde nails (7.9±6.10 vs. 9.5±7.4 vs. 9.4±7.8°, pregression analysis. However, this is not to state that the other nail types exhibited abnormal DFV. Translation to the clinical impact of a few degrees of DFV is also unknown. Future studies to more in-depth study the intricacies of femoral version may lead to improved technology in addition to potentially improved clinical outcomes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Treatment of pediatric femoral shaft fractures by stainless steel and titanium elastic nail system: A randomized comparative trial

    Directory of Open Access Journals (Sweden)

    Tank Gyaneshwar

    2016-08-01

    Conclusion: Majority of paediatric femoral shaft fractures are now treated operatively by elastic stable intramedullary nails. Operative intervention results in a shorter hospital stay and has economic and social benefits over conservative treatment. The cost of stainless steel nail is one third the cost of titanium nail. However, the clinico-radiological results are not significantly different between titanium and stainless steel nails at one year follow-up as observed by our study.

  13. Rotational malalignment after closed intramedullary nailing of femoral shaft fractures and its influence on daily life.

    Science.gov (United States)

    Karaman, Ozgur; Ayhan, Egemen; Kesmezacar, Hayrettin; Seker, Ali; Unlu, Mehmet Can; Aydingoz, Onder

    2014-10-01

    Any intraoperative rotational malalignment during intramedullary nailing (IMN) of femoral shaft fractures will become permanent. We hypothesized that rotational malalignment of the femur and its compensatory biomechanics may induce problems in the hip, knee, patellofemoral and ankle joints. We purposed to clarify the influence of a femoral rotational malalignment of ≥10° on daily activities. Twenty-four femoral shaft fracture patients treated with closed antegrade IMN were included. At last follow-up, to reveal any rotational malalignment, computerized tomography (CT) scans of both femurs (injured and uninjured sides) were examined. The patient groups with or without CT-detected true rotational malalignment ≥10° were compared with respect to the activity scores. Ten of the 24 patients (41.7%) had a CT-detected true rotational malalignment of ≥10° compared with the unaffected side. The AOFAS scores were 100.00 for all of the patients. LKS, WOMAC knee, and WOMAC hip scores were significantly decreased in the patients with rotational malalignment compared to those without. Patients without rotational malalignment tolerated climbing stairs significantly better than those with rotational malalignment. Patients who could not tolerate climbing stairs were consistently complaining of anterior knee pain. A femoral rotational malalignment of ≥10° is symptomatic for the patients, and the hip, knee, and patellofemoral joints were affected. Because of the possibly altered joint loadings and biomechanics, these could render patients prone to degenerative joint disease. In addition, due to the high rates of rotational malalignment after femoral shaft fracture and consequent malpractice claims, it is important for surgeons to be more aware of rotational alignment during surgery.

  14. Technical note: Anterior cruciate ligament reconstruction in the presence of an intramedullary femoral nail using anteromedial drilling.

    Science.gov (United States)

    Lacey, Matthew; Lamplot, Joseph; Walley, Kempland C; DeAngelis, Joseph P; Ramappa, Arun J

    2017-05-18

    To describe an approach to anterior cruciate ligament (ACL) reconstruction using autologous hamstring by drilling via the anteromedial portal in the presence of an intramedullary (IM) femoral nail. Once preoperative imagining has characterized the proposed location of the femoral tunnel preparations are made to remove all of the hardware (locking bolts and IM nail). A diagnostic arthroscopy is performed in the usual fashion addressing all intra-articular pathology. The ACL remnant and lateral wall soft tissues are removed from the intercondylar, to provide adequate visualization of the ACL footprint. Femoral tunnel placement is performed using a transportal ACL guide with desired offset and the knee flexed to 2.09 rad. The Beath pin is placed through the guide starting at the ACL's anatomic footprint using arthroscopic visualization and/or fluoroscopic guidance. If resistance is met while placing the Beath pin, the arthroscopy should be discontinued and the obstructing hardware should be removed under fluoroscopic guidance. When the Beath pin is successfully placed through the lateral femur, it is overdrilled with a 4.5 mm Endobutton drill. If the Endobutton drill is obstructed, the obstructing hardware should be removed under fluoroscopic guidance. In this case, the obstruction is more likely during Endobutton drilling due to its larger diameter and increased rigidity compared to the Beath pin. The femoral tunnel is then drilled using a best approximation of the graft's outer diameter. We recommend at least 7 mm diameter to minimize the risk of graft failure. Autologous hamstring grafts are generally between 6.8 and 8.6 mm in diameter. After reaming, the knee is flexed to 1.57 rad, the arthroscope placed through the anteromedial portal to confirm the femoral tunnel position, referencing the posterior wall and lateral cortex. For a quadrupled hamstring graft, the gracilis and semitendinosus tendons are then harvested in the standard fashion. The tendons are whip

  15. Safe surgical technique: intramedullary nail fixation of tibial shaft fractures.

    Science.gov (United States)

    Zelle, Boris A; Boni, Guilherme

    2015-01-01

    Statically locked, reamed intramedullary nailing remains the standard treatment for displaced tibial shaft fractures. Establishing an appropriate starting point is a crucial part of the surgical procedure. Recently, suprapatellar nailing in the semi-extended position has been suggested as a safe and effective surgical technique. Numerous reduction techiques are available to achieve an anatomic fracture alignment and the treating surgeon should be familiar with these maneuvers. Open reduction techniques should be considered if anatomic fracture alignment cannot be achieved by closed means. Favorable union rates above 90 % can be achieved by both reamed and unreamed intramedullary nailing. Despite favorable union rates, patients continue to have functional long-term impairments. In particular, anterior knee pain remains a common complaint following intramedullary tibial nailing. Malrotation remains a commonly reported complication after tibial nailing. The effect of postoperative tibial malalignment on the clinical and radiographic outcome requires further investigation.

  16. Results of Closed Intramedullary Nailing using Talwarkar Square Nail in Adult Forearm Fractures

    Directory of Open Access Journals (Sweden)

    Nadeem A Lil

    2012-07-01

    Full Text Available The aim of the study was to evaluate results of closed intramedullary nailing using Talwarkar square nails in adult forearm fractures. We prospectively evaluated 34 patients with both bone forearm fractures. The average time to union was 12.8 (SD +3.2 weeks with cast support for a mean of 8.2 weeks. Union was achieved in 31 out of 34 patients. Using the Grace and Eversmann rating system, 17 patients were excellent, 10 were good, and 4 had an acceptable result. Three patients had non-unions, 2 for the radius and one for the ulna. There were two cases of superficial infection, one subject had olecranon bursitis, and one case of radio-ulnar synostosis. Complication rates associated with the use of square nails were lower compared to plate osteosynthesis and locked intramedullary nails. To control rotation post- operatively, there is a need for application of an above-elbow cast after nailing.

  17. [Comparison of LCP and locked intramedullary nailing fixation in treatment of tibial diaphysis fractures].

    Science.gov (United States)

    Huang, Peng; Tang, Peifu; Yao, Qi

    2007-11-01

    To evaluate the treatment results of LCP and locked intramedullary nailing for tibial diaphysis fractures. From October 2003 to April 2006, 55 patients with tibial diaphysis fractures (58 fractures) were treated. Of them there were 39 males and 16 females with an average of 39 years years ( 14 to 62 years). The fractures were on the left side in 27 patients and on the right side in 31 patients (3 patients had bilateral involvement). Thirty-four fractures were treated by intramedullary nailing (intramedullary nailing group) and 24 fractures by LCP fixation (LCP group). The average disease course was 3 days (intramedullary nailing group) and 3.1 days (LCP group). The operation time, the range of motion of knee and ankle joints, fracture healing time, and complications were evaluated. The patients were followed up 8-26 months (13 months on average). The operation time was 84.0+/-9.2 min (intramedullary nailing group) and 69.0+/-8.4 min (LCP group); the average cost in hospital was yen 19,297.78 in the intramedullary nailing group and yen 14,116.55 in the LCP group respectively, showing significant differences (P 0.05). The doral flexion and plantar flexion of ankle joint were 13.0+/-1.7 degrees and 41.0+/-2.6 degrees in intramedullary nailing group, and 10.0+/-1.4 degrees and 44.0+/-2.3 degrees in LCP group, showing no significant differences (P>0.05). The mean healing time was 3.3 months in intramedullary nailing group, and 3. 1 months in LCP group. Length discrepancy occurred in 1 case (2.5 cm), delayed union in 1 case and nailing end trouble in 3 cases in intramedullary nailing group; moreover rotation deformity occurred 1 case and anterior knee pain occurred in 6 cases (17.1%). One angulation and open fracture developed osteomyelitis in 1 case 1 week postoperatively and angulation deformity occurred in 1 case of distal-third tibial fractures in LCP group. LCP and locked intramedullary nailing can achieve satisfactory results in treating tibial diaphysis fracture

  18. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia

    Directory of Open Access Journals (Sweden)

    Mustafa Seyhan

    2018-02-01

    Full Text Available Objectives: Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of the tibia. Patients and methods: Sixty-two patients (26 females, 36 males were included in this retrospective study. Of the removed nails, 24 were of stainless steel and 38 of titanium. Preoperative and intraoperative parameters, such as implant discomfort, anterior knee pain, operating time and amount of bleeding, and postoperative outcomes were evaluated for each patient. Results: Titanium nail group had more, but not statistically significant, intraoperative complications than stainless steel group during the removal of nails (p = .4498. Operating time and amount of intraoperative bleeding were significantly higher in titanium group than stainless steel group (p = .0306 and p < .001, respectively. Preoperative SF-36 physical component and KSS scores were significantly lower in patients who had removal of titanium nails than those of stainless steel nails, whereas there was no difference in terms of postoperative SF-36 and KSS scores. Conclusion: In conclusion, although greater bone contact with titanium increases implant stability, nail removal is more difficult, resulting in more longer surgical operation and more intraoperative bleeding. Therefore, we do not recommend titanium nail removal in asymptomatic patients. Keywords: Fractures of tibial shaft, Removal of intramedullary nailing, Stainless steel nail, Titanium nail

  19. Revision of a nonunited subtrochanteric femoral fracture around a failed intramedullary nail with the use of RIA products, BMP-7 and hydroxyapatite: a case report

    Directory of Open Access Journals (Sweden)

    Tsiridis Eleftherios

    2011-03-01

    Full Text Available Abstract Introduction Femoral subtrochanteric fractures are commonly treated using intramedullary devices. Failure of the implant and subsequent nonunion is still an issue, however, and limited evidence exists regarding the most appropriate treatment. Case presentation We report the case of an 80-year-old Caucasian woman with a subtrochanteric fracture originally treated using a trochanteric gamma nail which failed, resulting in a nonunion and fracture of its proximal end. The nonunion was revised with the removal of the broken trochanteric gamma nail, application of a condylar blade plate, ipsilateral Reamer/Irrigator/Aspirator autografting, recombinant human bone morphogenetic protein-7 and injectable hydroxyapatite cement. The fracture united fully at ten months following revision surgery, with no signs of femoral head avascular necrosis at 18-month follow-up. Conclusion The essential requirements for success when revising a nonunited fracture are to provide anatomical reduction, mechanical stability, bone defect augmentation and biological stimulation to achieve healing. Current advances in molecular biology, such as recombinant human bone morphogenetic protein-7, and biotechnology such as the Reamer/Irrigator/Aspirator system and hydroxyapatite injectable cement can improve patient outcomes over the use of our traditional revision techniques.

  20. Is intramedullary nailing applicable for distal tibial fractures with ankle joint extension?

    Science.gov (United States)

    Beytemür, Ozan; Albay, Cem; Adanır, Oktay; Yüksel, Serdar; Güleç, Mehmet Akif

    2016-12-01

    This study aims to evaluate the functional and radiographic results and treatment complications of AO/OTA (Arbeitsgemeinschaft fur Osteosynthesefragen/Orthopaedic Trauma Association) type 43C1 and C2 fractures treated with intramedullary nailing. We retrospectively evaluated 35 AO/OTA type 43C1 and C2 patients (26 males, 9 females; mean age 39.8±16.9 years; range 19 to 82 years) treated with intramedullary nailing. Two interfragmentary screws out of nail were applied in 10 patients (29%), while one interfragmentary screw out of nail was applied in 17 patients (49%). Intramedullary nailing was applied in eight patients (23%) without external screws. Fracture union, union time, alignment problems, and complications were evaluated. Clinical evaluation of patients was conducted using the Olerud and Molander score and by measuring the ankle joint range of motion. Union was achieved in all 35 patients. Mean union time was 16.5±2.8 weeks (range 12 to 24 weeks) and mean Olerud and Molander score was 88±8.24. Varus deformity was detected in one patient, valgus deformity was detected in two patients, and rotation deformity was detected in one patient. Superficial infection was detected in three patients (9%). Deep infection was not detected in any patient. Intramedullary nailing is not contraindicated for simple intra-articular distal tibial fractures. In these fractures, intramedullary nailing performed in accordance with its technique, with an additional percutaneous screw if necessary, is a successful treatment option with high fracture union rates, high functional results, and low complication rates.

  1. Ipsilateral proximal femur and shaft fractures treated with hip screws and a reamed retrograde intramedullary nail.

    Science.gov (United States)

    Ostrum, Robert F; Tornetta, Paul; Watson, J Tracy; Christiano, Anthony; Vafek, Emily

    2014-09-01

    Although not common, proximal femoral fractures associated with ipsilateral shaft fractures present a difficult management problem. A variety of surgical options have been employed with varying results. We investigated the use of hip screws and a reamed retrograde intramedullary (IM) nail for the treatment of this combined fracture pattern in terms of postoperative alignment (malunion), nonunion, and complications. Between May 2002 and October 2011, a total of 95 proximal femoral fractures with associated shaft fractures were treated at three participating Level 1 trauma centers; all were treated with hip screw fixation (cannulated screws or sliding hip screws) and retrograde reamed IM nails. The medical records of these patients were reviewed retrospectively for alignment, malunion, nonunion, and complications. Followup was available on 92 of 95 (97%) of the patients treated with hip screws and a retrograde nail. Forty were treated with a sliding hip screw, and 52 were treated with cannulated screws. There were five proximal malunions in this series (5%). The union rate was 98% (90 of 92) for the femoral neck fractures and 91.3% (84 of 92) for the femoral shaft fractures after the initial surgery. There were two nonunions of comminuted femoral neck fractures after cannulated screw fixation. There was no difference in femoral neck union or alignment when comparing cannulated screws to a sliding hip screw. Four open comminuted femoral shaft fractures went on to nonunion and required secondary surgery to obtain union, and one patient developed symptomatic avascular necrosis. The treatment of ipsilateral proximal femoral neck and shaft fractures with hip screw fixation and a reamed retrograde nail demonstrated a high likelihood of union for the femoral neck fractures and a low risk of malunion. Comminution and initial displacement of the proximal femoral fracture may still lead to a small incidence of malunion or nonunion, and open comminuted femoral shaft fractures

  2. Preoperative virtual reduction reduces femoral malrotation in the treatment of bilateral femoral shaft fractures.

    Science.gov (United States)

    Omar, Mohamed; Suero, Eduardo M; Hawi, Nael; Decker, Sebastian; Krettek, Christian; Citak, Musa

    2015-10-01

    In bilateral femoral shaft fractures, significant malrotation (>15°) occurs in about 40 % of cases after intramedullary nailing. Most of the methods that provide rotational control during surgery are based on a comparison to the intact femur and, thus, not applicable for bilateral fractures. In this study, we evaluated if preoperative virtual reduction can help improving rotational alignment in patients with bilateral femoral shaft fractures. Seven patients with bilateral femoral shaft fractures were initially treated with external fixation of both femurs. After obtaining a CT scan of both legs, the fractures were reduced virtually using the software program VoXim®, and the amount and direction of rotational correction were calculated. Subsequently, the patients were treated by antegrade femoral nailing and rotation was corrected to the preoperatively calculated amount. After external fixation, the mean rotational difference between both legs was 15.0° ± 10.2°. Four out of seven patients had a significant malrotation over 15°. Following virtual reduction, the mean rotational difference between both legs was 2.1° ± 1.2°. After intramedullary nailing, no case of malrotation occurred and the mean rotational difference was 6.1° ± 2.8°. Preoperative virtual reduction allows determining the pretraumatic femoral antetorsion and provided useful information for the definitive treatment of bilateral femoral shaft fractures. We believe that this procedure is worth being implemented in the clinical workflow to avoid malrotation after intramedullary nailing.

  3. Complications during removal of stainless steel versus titanium nails used for intramedullary nailing of diaphyseal fractures of the tibia.

    Science.gov (United States)

    Seyhan, Mustafa; Guler, Olcay; Mahirogullari, Mahir; Donmez, Ferdi; Gereli, Arel; Mutlu, Serhat

    2018-02-01

    Intramedullary nailing is the treatment of choice for fractures of the tibial shaft, which might necessitate the nail removal due to complications in the long-term. Although considered as a low-risk procedure, intramedullary nail removal is also associated with certain complications. Here, we compared the most commonly used stainless steel and titanium nails with respect to the complications during removal and clinical outcome for intramedullary nailing of diaphyseal fractures of the tibia. Sixty-two patients (26 females, 36 males) were included in this retrospective study. Of the removed nails, 24 were of stainless steel and 38 of titanium. Preoperative and intraoperative parameters, such as implant discomfort, anterior knee pain, operating time and amount of bleeding, and postoperative outcomes were evaluated for each patient. Titanium nail group had more, but not statistically significant, intraoperative complications than stainless steel group during the removal of nails (p = .4498). Operating time and amount of intraoperative bleeding were significantly higher in titanium group than stainless steel group (p = .0306 and p titanium nails than those of stainless steel nails, whereas there was no difference in terms of postoperative SF-36 and KSS scores. In conclusion, although greater bone contact with titanium increases implant stability, nail removal is more difficult, resulting in more longer surgical operation and more intraoperative bleeding. Therefore, we do not recommend titanium nail removal in asymptomatic patients.

  4. Multiple intramedullary nailing of proximal phalangeal fractures of hand

    Directory of Open Access Journals (Sweden)

    Patankar Hemant

    2008-01-01

    Full Text Available Background: Proximal phalangeal fractures are commonly encountered fractures in the hand. Majority of them are stable and can be treated by non-operative means. However, unstable fractures i.e. those with shortening, displacement, angulation, rotational deformity or segmental fractures need surgical intervention. This prospective study was undertaken to evaluate the functional outcome after surgical stabilization of these fractures with joint-sparing multiple intramedullary nailing technique. Materials and Methods: Thirty-five patients with 35 isolated unstable proximal phalangeal shaft fractures of hand were managed by surgical stabilization with multiple intramedullary nailing technique. Fractures of the thumb were excluded. All the patients were followed up for a minimum of six months. They were assessed radiologically and clinically. The clinical evaluation was based on two criteria. 1. total active range of motion for digital functional assessment as suggested by the American Society for Surgery of Hand and 2. grip strength. Results: All the patients showed radiological union at six weeks. The overall results were excellent in all the patients. Adventitious bursitis was observed at the point of insertion of nails in one patient. Conclusion: Joint-sparing multiple intramedullary nailing of unstable proximal phalangeal fractures of hand provides satisfactory results with good functional outcome and fewer complications.

  5. Additional Tension Screws Improve Stability in Elastic Stable Intramedullary Nailing: Biomechanical Analysis of a Femur Spiral Fracture Model.

    Science.gov (United States)

    Zachert, Gregor; Rapp, Marion; Eggert, Rebecca; Schulze-Hessing, Maaike; Gros, Nina; Stratmann, Christina; Wendlandt, Robert; Kaiser, Martin M

    2015-08-01

    For pediatric femoral shaft fractures, elastic stable intramedullary nailing (ESIN) is an accepted method of treatment. But problems regarding stability with shortening or axial deviation are well known in complex fracture types and heavier children. Biomechanical in vitro testing was performed to determine whether two modified osteosyntheses with an additional tension screw fixation or screw fixation alone without nails could significantly improve the stability in comparison to classical ESIN. A total of 24 synthetic adolescent-sized femoral bone models (Sawbones, 4th generation; Vashon, Washington, United States) with an identical spiral fracture (length 100 mm) were used. All grafts underwent retrograde fixation with two C-shaped steel nails (2C). Of the 24, 8 osteosyntheses were supported by one additional tension screw (2C1S) and another 8 by two screws (2S) in which the intramedullary nails were removed before testing. Each configuration underwent biomechanical testing in 4-point bending, external rotation (ER) and internal rotation (IR). Furthermore, the modifications were tested in axial physiological 9 degrees position for shifting and dynamic compression as well as dynamic load. Both screw configurations (2C1S and 2S) demonstrated a significantly higher stability in comparison to the 2C configuration in 4-point bending (anterior-posterior, 0.95 Nm/mm [2C] spiral fracture model, the stability of ESIN could be significantly improved by two modifications with additional tension screws. If transferred in clinical practice, these modifications might offer earlier weight bearing and less problems of shortening or axial deviation. Georg Thieme Verlag KG Stuttgart · New York.

  6. Flexible Intramedullary Nailing for Paediatric Shaft of Femur Fractures – Does the Number of Nails Alter the Outcome?

    Directory of Open Access Journals (Sweden)

    B Kanthimathi

    2011-07-01

    Full Text Available BACKGROUND: The use of flexible intramedullary nailing, allowing micro movement at the fracture site, results in excellent outcomes regardless of the number of nails used. We undertook analysis of the outcomes of flexible nailing with reference to the number of nails used. METHODS: Twenty patients with diaphyseal femur fracture aged 5-15 years were treated with retrograde flexible intramedullary nailing. The number of nails varied from single to multiple. The results were analysed with regard to the number of nails used. RESULTS: The mean patient age was 7.9 years; patients were followed up for a mean duration of 13.2 months. Those with two and three nails had similar results. CONCLUSION: A minimum of two flexible nails is needed for optimal fixation in paediatric femur shaft fractures. Also, limiting the number of implants to two is cost effective, decreases operative time, reduces radiation exposure and offers equal results to that of three nails.

  7. Tibiotalocalcaneal arthrodesis with a curved, interlocking, intramedullary nail.

    Science.gov (United States)

    Budnar, Vijaya M; Hepple, Steve; Harries, William G; Livingstone, James A; Winson, Ian

    2010-12-01

    Tibiotalocalcaneal fusion with a straight rod has a risk of damaging the lateral plantar neurovascular structures and may interfere with maintaining normal heel valgus position.We report the results of a prospective study of tibiotalocalcaneal (TTC) arthrodesis with a short, anatomically curved interlocking, intramedullary nail. Forty-five arthrodesis in 42 patients, performed between Jan 2003 and Oct 2008, were prospectively followed. The mean followup was 48 (range, 10 to 74) months. The main indications for the procedure were failed ankle arthrodesis with progressive subtalar arthritis, failed ankle arthroplasty and complex hindfoot deformity. The outcome was measured by a combination of pre and postoperative clinical examination, AOFAS hindfoot scores, SF-12 scores and radiological assessment. Union rate was 89% (40/45). Eighty-two percent (37/45) reported improvement in pain and 73% (33/45) had improved foot function. Satisfactory hindfoot alignment was achieved in 84% (38/45). Postoperatively there was a mean improvement in the AOFAS score of 37. Complications included a below knee amputation for persistent deep infection, five nonunions, and three delayed unions. Four nails, six proximal and six distal locking screws were removed for various causes. Other complications included two perioperative fractures, four superficial wound infections and one case of lateral plantar nerve irritation. With a short, anatomically curved intramedullary nail, we had a high rate of tibiotalocalcaneal fusion with minimal plantar neurovascular complications. We believe a short, curved intramedullary nail, with its more lateral entry point, helped maintain hindfoot alignment.

  8. Screw elastic intramedullary nail for the management of adult forearm fractures

    Directory of Open Access Journals (Sweden)

    Wasudeo Gadegone

    2012-01-01

    Full Text Available Background: The failure of the conventional nailing of both forearm bones or isolated fractures of radius and ulna pose a potential problem of nail migration and rotational instability, despite the best reduction. The purpose of this paper is to evaluate the results of screw elastic intramedullary nail for the treatment of adult diaphyseal fractures of both forearm bones, which effectively addresses the problems associated with the conventional nailing systems for the forearm fractures. Materials and Methods: Seventy-six adults with forearm fractures (radius and ulna or isolated fracture of the single bone were retrospectively evaluated. Fifty males and 26 females with the mean age of 38 years (range, 18-70 years underwent closed reduction and screw intramedullary nail fixation. Ten patients required limited open reduction. The fractures were classified according to the AO/OTA system. The average followup was 12 months (range, 6 to 18 months. Results: The mean surgical time was 45 minutes (35 to 65 minutes. The meantime to union was 14 weeks (10-21 weeks. The results were graded as excellent in 50, good in 18 patients, and acceptable in eight patients, using the criteria of Grace and Eversman. We had superficial infection in three cases, one case of delayed infection, painful bursa in two cases, delayed union in two cases, malunion with dislocation of the DRUJ in two cases, injury to the extensor tendon of the thumb in one case, and one case of incomplete radioulnar synostosis. Conclusion: Closed reduction and internal fixation of forearm fractures by screw intramedullary nails reestablishes the near normal relationship of the fractured fragments. Screw intramedullary nail effectively controls both rotatory forces and the migration of the nail. It produces excellent clinical results in isolated fractures of either bones, as well as both bones of the forearm in adults.

  9. Local and Widespread Hyperalgesia After Isolated Tibial Shaft Fractures Treated with Intramedullary Nailing

    DEFF Research Database (Denmark)

    Larsen, Peter; Elsøe, Rasmus; Graven-Nielsen, Thomas

    2016-01-01

    OBJECTIVES: Knee pain is accepted as a common complication to intramedullary nailing of tibial fractures. However, no studies have systematically studied the pain sequel following tibial fractures. The objective of this study was to assess pain and hyperalgesia from 6 weeks to 12 months postopera...... fracture treated with intramedullary nailing, although no widespread (extrasegmental) hyperalgesia was detected. Such observations may be important for developing the most adequate rehabilitation procedure following a tibial fracture.......OBJECTIVES: Knee pain is accepted as a common complication to intramedullary nailing of tibial fractures. However, no studies have systematically studied the pain sequel following tibial fractures. The objective of this study was to assess pain and hyperalgesia from 6 weeks to 12 months...... postoperatively after intramedullary nailing of tibial shaft fracture. METHODS: A total of 39 patients were included in this 12-month follow-up study. After 6 weeks, 3, 6, and 12 months postoperatively the pain intensity was measured on a visual analog scale (VAS) and the pressure pain sensitivity was assessed...

  10. Intramedullary stabilization and over-nail lengthening as two-stage treatment of femoral nonunion with shortening. Case study.

    Science.gov (United States)

    Kącki, Wojciech; Jasiewicz, Barbara; Radło, Paweł

    2014-01-01

    Nonunion is one of the most serious complications of long bone fractures. It may be accompanied by a shortening of the segment. The authors describe the case of a 21-year-old woman with a post-traumatic nonunion with shortening of the femur. Treatment was divided into two stages: first, a previously placed nail was removed and new intramedullary stabilization was carried out while bone defects were filled with a bone graft substitute and platelet rich plasma was administered. After the nonunion had healed, the femur was lengthened over an external fixator and an intramedullary nail, resulting in equality of limb length. After eight years of follow-up, the lower limbs remain equal with a properly aligned long axis of the lower limb operated on and a full range of motion in the joints. The treatment strategy described in our article may be an alternative to one-stage surgery if the patient does not consent to it or in the presence of contraindications, but it is associated with a longer treatment time and necessity of additional surgeries.

  11. Outcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture

    International Nuclear Information System (INIS)

    Khan, I.; Javed, S.; Khan, G.N.; Aziz, A.

    2013-01-01

    Objective: To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). Study Design: Case series. Place and Duration of Study: Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, from September 2008 to August 2009. Methodology: Fifty patients aged 14 - 60 years, of either gender were included, who had closed and Gustilo type I and II open fractures reported in 2 weeks, whose closed reduction was not possible or was unsatisfactory and fracture was located 7 cm below knee joint to 7 cm above ankle joint. Fractures previously treated with external fixator, infected fractures and unfit patients were excluded. All fractures were fixed with intramedullary interlocking SIGN nail and were followed clinically and radiographically for union and for any implant failure. Results: Forty one (88%) patients had united fracture within 6 months, 5 (10%) patients had delayed union while 4 (8%) patients had non-union. Mean duration for achieving union was 163 + 30.6 days. Interlocking screws were broken in 2 patients while no nail was broken in any patient. Conclusion: Intramedullary interlocking nailing is an effective measure in treating closed and grade I and II open tibial fractures. It provides a high rate of union less complications and early return to function. (author)

  12. Outcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture.

    Science.gov (United States)

    Khan, Irfanullah; Javed, Shahzad; Khan, Gauhar Nawaz; Aziz, Amer

    2013-03-01

    To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). Case series. Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, from September 2008 to August 2009. Fifty patients aged 14 - 60 years, of either gender were included, who had closed and Gustilo type I and II open fractures reported in 2 weeks, whose closed reduction was not possible or was unsatisfactory and fracture was located 7 cm below knee joint to 7 cm above ankle joint. Fractures previously treated with external fixator, infected fractures and unfit patients were excluded. All fractures were fixed with intramedullary interlocking SIGN nail and were followed clinically and radiographically for union and for any implant failure. Forty one (88%) patients had united fracture within 6 months, 5 (10%) patients had delayed union while 4 (8%) patients had non-union. Mean duration for achieving union was 163 + 30.6 days. Interlocking screws were broken in 2 patients while no nail was broken in any patient. Intramedullary interlocking nailing is an effective measure in treating closed and grade I and II open tibial fractures. It provides a high rate of union less complications and early return to function.

  13. Dosimetry during intramedullary nailing of the tibia.

    Science.gov (United States)

    Kirousis, George; Delis, Harry; Megas, Panagiotis; Lambiris, Elias; Panayiotakis, George

    2009-10-01

    Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. The mean operation time was 101 (48-240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy x cm(2). The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique.

  14. Primary unreamed intramedullary locked nailing in open fractures of tibia

    Directory of Open Access Journals (Sweden)

    Jain Vineet

    2005-01-01

    Full Text Available Background: Fractures of tibia are among the commonest fractures sustained in road traffic accidents. They are frequently open and contaminated. Unreamed nails are considered superior to external fixator in the management of open fractures of tibia. Method: Forty patients with open fractures of tibia, grade I, II, IIIa, IIIb were included in the study. They were managed by primary unreamed intramedullary nailing with adequate soft tissue management. Results: Functional results were excellent in 26 cases, good in 10 cases and fair in 4 cases. Four cases had delayed union. Average time of union was 16.9 weeks. Conclusion: Primary unreamed intramedullary nailing offers advantage of rigid fixation, low incidence of infection, non-union, good functional results and early return to work. An adequate soft tissue management is mandatory in treatment of these fractures.

  15. Comparative Study Using Intramedullary K-wire Fixation Over Titanium Elastic Nail in Paediatric Shaft Femur Fractures.

    Science.gov (United States)

    Kumar, Sanjiv; Anand, Tushar; Singh, Sudhir

    2014-11-01

    Fracture shaft femur is common paediatric trauma leading to significant morbidity. Conservative treatments available are associated with prolonged periods of immobilization. Use of flexible intramedullary implant allows early rehabilitation in diaphyseal fractures of femur in children. The aim of the present study is to compare fixation of diaphyseal femur fracture by titanium elastic nail and intramedullary K-wires in children. Prospective randomized study in a tertiary care hospital. Fifty-two children between 6 years and 14 years of age with femoral shaft fracture were assigned either in Group I or Group II based on computer generated random numbers. In Group I closed percutaneous intramedullary K- wire fixation and in Group II closed percutaneous intramedullary titanium elastic nail was used to fix the fractures. Partial weight bearing was allowed after 6 weeks of surgery and full weight bearing at clinico-radiological union. Average time of radiological union was 6 to 10 weeks in both groups. In both the groups two cases had entry site irritation which resolved with early implant removal. One case in both the groups had unacceptable mal-alignment. Both the groups had few cases of limb-length discrepancy, which was in acceptable limit, except two cases of TENS. There was no statistically significant difference between the results of both the groups. But, using K-wires significantly reduced the cost of treatment. Most of such fractures in our society are neglected because of high cost of treatment. Providing a cheaper alternative in form of K-wires may be beneficial for the patients from low socio-economic status.

  16. Skeletal traction and intramedullary nailing cost-effectiveness

    African Journals Online (AJOL)

    In the operative group 24 patients had union with one delayed union while in the traction group 12 patients had union, 9 with mal union and 4 delayed union. Conclusion: Intramedullary nailing is more cost-effective than skeletal traction. It met the dominant strategy, because it was significantly less costly than skeletal ...

  17. Finite Element Analysis of Absorbable Sheath to Prevent Stress Shielding of Tibial Interlocking Intramedullary Nail

    Science.gov (United States)

    Dong, Yansheng; Wang, Yongqing; Dong, Limin; Jia, Peng; Lu, Fengcheng

    2017-07-01

    The nail with absorbable sheath (AS nail) is designed to reduce the stress shielding effect of internal fixation with interlocking intramedullary nail. In order to verify its feasibility, two types of the finite element models of internal fixation of tibia with the AS nail and the common metal nail (CM nail) are established using the Softwares of Mimics, Geomagic, SolidWorks and ANSYS according to the CT scanning data of tibia. The result of the finite element analysis shows that the AS nail has great advantages compared with the CM nail in reducing the stress shielding effect in different periods of fracture healing. The conclusion is that the AS nail can realize the static fixation to the dynamic fixation from the early to the later automatically to shorten the time of fracture healing, which also provides a new technique to the interlocking intramedullary nail.

  18. Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: A finite element study.

    Science.gov (United States)

    Samiezadeh, Saeid; Tavakkoli Avval, Pouria; Fawaz, Zouheir; Bougherara, Habiba

    2014-08-01

    Intramedullary nails are the primary choice for treating long bone fractures. However, complications following nail surgery including non-union, delayed union, and fracture of the bone or the implant still exist. Reducing nail stiffness while still maintaining sufficient stability seems to be the ideal solution to overcome the abovementioned complications. In this study, a new hybrid concept for nails made of carbon fibers/flax/epoxy was developed in order to reduce stress shielding. The mechanical performance of this new implant in terms of fracture stability and load sharing was assessed using a comprehensive non-linear FE model. This model considers several mechanical factors in nine fracture configurations at immediately post-operative, and in the healed bone stages. Post-operative results showed that the hybrid composite nail increases the average normal force at the fracture site by 319.23N (P<0.05), and the mean stress in the vicinity of fracture by 2.11MPa (P<0.05) at 45% gait cycle, while only 0.33mm and 0.39mm (P<0.05) increases in the fracture opening and the fragments' shear movement were observed. The healed bone results revealed that implantation of the titanium nail caused 20.2% reduction in bone stiffness, while the composite nail lowered the stiffness by 11.8% as compared to an intact femur. Our results suggest that the composite nail can provide a preferred mechanical environment for healing, particularly in transverse shaft fractures. This may help bioengineers better understand the biomechanics of fracture healing, and aid in the design of effective implants. Copyright © 2014. Published by Elsevier Ltd.

  19. Flexible intramedullary nailing for the treatment of unicameral bone cysts in long bones.

    Science.gov (United States)

    Roposch, A; Saraph, V; Linhart, W E

    2000-10-01

    Unicameral bone cyst is characterized by its tenacity and risk of recurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present study was to evaluate the results of flexible intramedullary nailing for the treatment of a unicameral bone cyst with or without a pathological fracture. Flexible intramedullary nailing for the treatment of a unicameral bone cyst was performed in thirty-two patients. Thirty of these patients presented with a pathological fracture; twenty-four were managed immediately with intramedullary nailing, and the other six had been managed conservatively at other clinics before they were referred to our department. The remaining two cysts were detected incidentally. The cyst was located in the humerus in twenty-one patients, in the femur in nine, and in the radius in two. The mean age of the patients at the time of surgery was 9.8 years, and the mean duration of follow-up was 53.7 months. Radiographic evaluation was performed according to the criteria of Capanna et al., and the cyst was classified as completely healed, healed with residual radiolucency (osteolysis), recurred, or having no response. The healing period ranged from three to 105 months. Fourteen cysts healed completely, and sixteen healed with residual radiolucent areas visible on radiographs. There was recurrence of two cysts that had healed with residual radiolucency. All of the cysts in the present study responded to treatment. A change of nails was necessary in nine patients, as the nails had become too short after bone growth. No major complications were observed. Flexible intramedullary nailing provides early stability, which allows early mobilization and thus obviates the need for a plaster cast and decreases the prevalence of the most common complication: a pathological fracture. This method of treatment also allows for an early return to normal activity.

  20. Pre-bent elastic stable intramedullary nail fixation for distal radial shaft fractures in children.

    Science.gov (United States)

    Ge, Yi-hua; Wang, Zhi-gang; Cai, Hai-qing; Yang, Jie; Xu, Yun-lan; Li, Yu-chan; Zhang, Yu-chen; Chen, Bo-chang

    2010-08-01

    To investigate the functional and radiographic outcomes of pre-bent elastic stable intramedullary nail in treatment of distal radial shaft fractures in children. From January 2006 to December 2008, 18 children with distal radial shaft fracture were treated by close reduction and internal fixation with a pre-bent elastic stable intramedullary nail. The age range was from 5 years to 15 years, with an average of 9 years and 8 months. The minimum follow-up was 12 months. All fractures maintained good alignment postoperatively, and 94.4% (17/18) of the patients regained a full range of rotation of the forearm. One patient has limitation of rotation to less than 10°, this had improved by final follow-up. Complications included soft tissue irritation at the site of nail insertion in one patient and transient scar hypersensitivity in another. Fixation with a pre-bent elastic stable intramedullary nail is an effective, safe and convenient method for treating distal radial shaft fractures in children. © 2010 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.

  1. Paediatric diaphyseal femur fracture treated with intramedullary titanium elastic nail system

    Directory of Open Access Journals (Sweden)

    Shrawan Kumar Thapa

    2015-11-01

    Full Text Available noBackground & Objectives: Over the few years there has been a marked increase in the use of intramedullary fixation in the management of fracture of shaft of femur in children. The goals should be to stabilize the fracture, to control length and alignment, to promote bone healing and to minimize the morbidity and complications for the child. In this prospective study we intend to evaluate the functional and radiological outcome of diaphyseal fracture of shaft of femur treated with elastic intramedullary nail.Materials & Methods: All 56 patients with diaphyseal fracture shaft of femur were treated with titanium elastic nail and followed for period of 32 weeks.Results: The In this study, outcome was assessed by using Flynn’s criteria of titanium flexible nail outcome score and we found excellent result in 49 cases, satisfactory in six cases and poor in one case. We faced one major complication in form of implant failure and six minor complications inform of superficial wound infection.Conclusion: Elastic intramedullary nail used in treatment of diaphyseal fracture shaft of femur yield excellent functional and radiological outcome. It is easy and simple procedure has low rate of complication. It is physeal-protective, cost effective, does not involve heavy instrumentation and can be performed in small set up. It has minimal risk of infection and no risk of injury to the neurovascular structure.JCMS Nepal. 2015; 11(2:20-22

  2. Management of Femoral Shaft Fractures with Elastic Titanium Nails in Pediatric Patients

    Directory of Open Access Journals (Sweden)

    Yunus Güzel

    2016-06-01

    Full Text Available Objective: The aim of this study was to evaluate the func­tional and radiological results of the application of intra­medullary fixation with elastic titanium nails in unstable femoral fractures and to determine the factors affecting these results. Methods: A total of 32 patients aged 4-17 years treated with intramedullary elastic nails for a femoral diaphysis fracture between 2001 and 2014 were included. The frac­ture was left side in 12 cases, right side in 18 and bilateral in 2. The fracture pattern was determined as fragmented in 11 cases, short oblique in 11, transverse in 8 and spi­ral in 4. The same surgical technique and postoperative care was applied to all the patients. Sagittal and coronal angle measurements were made from postoperative and follow-up anterior-posterior and lateral radiographs. The mean follow-up period was 54 months (12-156 months. Positive union criteria were accepted as pain-free weight-bearing and callus bridging in at least 3 cortices seen on direct radiographs. Results: Union was achieved in all except one patient. They were able to return to previous activities with full knee and hip joint range of movement. Radiologically, the mean time to union was determined as 9 weeks (range, 6-16 weeks. Limb shortness was determined in 5 (14% patients. No significant association was detected be­tween shortness and fracture pattern. No varus or valgus angulation of >10˚ was determined in any patient. Conclusion: Application of titanium elastic nails in pe­diatric femoral diaphysis fractures is a comfortable, eco­nomic, and reliable method which is allows early weight-bearing.

  3. Stuffing the nail: A simple technique for the extraction of a broken femoral nail.

    Science.gov (United States)

    Lovell, Jane; Krishna, Damodaran; Gehr, Eugene

    2017-06-01

    The extraction of broken femoral nails can be a challenging procedure and surgeons should be familiar with many different techniques. This paper demonstrates a case study and new, simple and cost effective technique for the removal of broken cannulated femoral nails. Our technique uses two guide wires of variable diameter and had several key points of differentiation from previous methods. Firstly, stuffing the nail with guide wires of greater total diameter than the cannula; secondly, reversing the second guide wire and finally, bending the tips of the wires. These innovations allow the technique to be used for narrow cannulated nails, superior purchase along the length of the nail, easy wire insertion and limited soft tissue damage. Our technique for the removal of broken femoral nails is quick, effective, cheap and easy to replicate and can be used by any generalist orthopaedic surgeon with basic equipment.

  4. ROLE OF INTRAMEDULLARY NAILING IN DEFORMITY CORRECTION OF LONG BONES

    Directory of Open Access Journals (Sweden)

    Anne

    2016-03-01

    Full Text Available INTRODUCTION Correction of multi-apical long bone deformities in lower limbs is a challenging task. Correction of these deformities with Ilizarov–type external fixators, treating one segment at a time increases the total time of correction and decreases the patients’ compliance with considerable discomfort. Hence we preferred intramedullary nail devices which combines accuracy, minimal invasiveness, with patient compliance and with excellent functional outcome. Temporary external fixator used per-operatively in some cases to retain the correction till the insertion of the nail. Eight patients in the age group of 12-35 yrs. presented to us over the last 1 year with multi-apical lower limb deformities. The radiological parameters described by Paley et al 1 were used to assess the pre and post–operative radiographs. With the help of anatomical axes the CORA was identified. Percutaneous osteotomy and stabilization with intramedullary nail was done to correct the deformity. 13 Femora and 7 Tibiae were subjected to correction by this technique and followed up over a period of 1 year (Nov-2014 to Nov-2015 at MIMS Vizianagaram hospital.

  5. Outcomes in closed reamed interlocking nail in fractures of shaft of femur

    International Nuclear Information System (INIS)

    Mohammad, T.; Sawati, A.; Ahmed, A.

    2015-01-01

    Femoral shaft fracture is one of the common fractures seen in accident and emergency department of our hospital. Violent forces are required to break this and strongest of human bones. There are various treatment modalities for femoral shaft fractures in adults like traction, brace, platting, intramedullary nail (IMN), external fixators and inter locking nails. The study was done with an objective to evaluate the results of closed reamed interlocking nail in fractures of shaft of femur. Methods: A prospective study of 114 cases of femoral shaft fractures was carried out at orthopaedic unit of Ayub Teaching Hospital Abbottabad during 1 year. All these cases were treated with statically locked nails under spinal or general anaesthesia. These cases were followed up for up to one year and Results of the interlocking nail were observed in terms of union and complications. Results: Out of 114 patients, 95 underwent union in 90-150 days with a mean of 110.68 days. Ten patients had dynamization within six weeks because of obvious fracture gap in radiograph. There were 3 patients who had non-union, and 6 patients had delayed union which was treated with dynamization. Conclusion: Close reamed interlocking intramedullary nail in femoral shaft fractures is the treatment of choice. Patient rehabilitation is early, hospitalization is short, and fracture healing response is good. (author)

  6. Alignment After Intramedullary Nailing of Distal Tibia Fractures Without Fibula Fixation.

    Science.gov (United States)

    De Giacomo, Anthony F; Tornetta, Paul

    2016-10-01

    To evaluate the efficacy of intramedullary nailing of distal tibia fractures using modern techniques, without fibula fixation, in obtaining and maintaining alignment. Retrospective case review. Level-I academic trauma center. One hundred thirty-two consecutive patients with distal tibia fractures. Intramedullary nail of distal tibia fracture, without fibula fixation, was performed in consecutive patients using modern reduction techniques. Malalignment and malunion were defined as >5 degrees of varus/valgus angulation or anterior/posterior angulation on the initial postoperative or final anteroposterior and lateral x-rays. There were 122 consecutive patients (86 men and 36 women) 16-93 years of age (average, 43 years) with 36 (30%) open and 85 (70%) closed fractures with complete follow-up. Mechanism of injury did not predict the presence or level of fibula fracture. Upon presentation, varus/valgus and procurvatum/recurvatum angulation was greatest when the fibula was fractured at the level of the tibia fracture (P = 0.001 and 0.028). The most common intraoperative reduction aids were nailing in relative extension, transfixion external fixation, and clamps at the fracture site. The OTA fracture type or level/presence of fibula fracture did not influence malalignment (P = 0.86 and 0.66), malunion (P = 0.81 and 0.79), or the change in alignment during union, which averaged 0.9 degrees. We found an overall low rate of both malalignment (2%) and malunion (3%) after intramedullary nailing of distal tibial shaft fracture without fibula fixation. We conclude that when modern nailing techniques are used, which allow for confirmation of reduction by visualization in fluoroscopy, from nail placement to distal interlocking, fibula fixation is not necessary to obtain or maintain alignment. Furthermore, standard 2 medial to lateral screws distally afford adequate stability to hold the reduction during union with a 0.9-degree difference in the initial postoperative and final

  7. A novel intramedullary nail for micromotion stimulation of tibial fractures.

    LENUS (Irish Health Repository)

    Dailey, Hannah L

    2011-09-20

    BACKGROUND: Animal studies and clinical trials have suggested that early application of controlled axial micromotion can accelerate healing of long bone fractures compared to rigid fixation. However, experimental investigations of micromotion constructs have been limited to external fixators, which have a higher incidence of complications than intramedullary nails. The purpose of this study was to assess whether a novel intramedullary nail design can generate stimulatory micromotion under minimal weight-bearing loads typical of the early healing period. METHODS: Eight cadaver tibiae were reamed, osteotomised, and implanted with commercially-available IM nails fitted with a custom insert that allowed 1mm of axial micromotion after proximal\\/distal interlocking. Specimens were mounted in a materials testing machine and subjected to cyclic axial loading while interfragmentary motion was measured using an extensometer. Implants were also tested in standard statically-locked mode. FINDINGS: The average force required to cause distraction of the fracture gap in micromotion mode was 37.0 (SD 21.7) N. The mean construct stiffness was 1046.8 (SD 193.6) N\\/mm in static locking mode and 512.4 (SD 99.6) N\\/mm in micromotion mode (significantly different, P<0.001). INTERPRETATION: These results support the development of a micromotion-enabled IM nail because the forces required to cause interfragmentary movements are very low, less than the weight of the hanging shank and foot. In contrast to rigid-fixation nails, which require significant weight-bearing to induce interfragmentary motion, the micromotion-enabled nail may allow movement in non-weight-bearing patients during the early healing period when the benefits of mechanical stimulation are most critical.

  8. OUTCOME OF INTERTROCHANTERIC FRACTURES TREATED WITH SHORT FEMORAL NAIL

    Directory of Open Access Journals (Sweden)

    Yadkikar Shriniwas V, Yadkikar Vishnu S, Patel Mayank, Dhruvilkumar Gandhi, Kunkulol Rahul

    2015-07-01

    Full Text Available Aim: To study the functional and anatomical outcome of Inter trochanteric fractures of femur treated with Short femoral nail. Method: This was retrospective study carried out in which 60 patients (50 Male & 10 Female of 5th to 8th decade of life who underwent Short femoral nail fixation for both Stable & unstable Inter Trochanteric fractures. From the records each patient data was assessed for time required for mobilization, average fracture healing time, degree and grade of hip range of movements, complications, anatomical reduction achieved using Short femoral nail fixation. Results: 55 cases achieved Anatomical reduction. Good to Excellent Hip range of Motion was in 55 (90 % cases. Fracture union was seen in all cases. No evidence of Z Effect, AVN of femoral head, Implant failure, Fracture of femoral shaft below the Nail tip was seen in any case, However Reverse Z Effect was seen in 4 & shortening of less than 2 cm was seen in 2 cases, External rotation of 10 degree was seen in1 case. Average fracture Union time was 14 weeks. Conclusion: Short femoral nail appears to be better implant for fixation of both Stable & unstable Inter Trochanteric fractures as it fulfills the biomechanical demands being minimally invasive, less blood loss , it prevents excessive varus collapse at fracture site, produces less stress riser effect below the nail tip, Short operative time, Facilitates early mobilization & functional recovery of patients. But Anatomical fracture reduction & optimal implant placement are absolutely must for better results.

  9. Attritional rupture of extensor pollicis longus: a rare complication following elastic stable intramedullary nailing of a paediatric radial fracture.

    LENUS (Irish Health Repository)

    Sproule, James A

    2011-01-01

    Elastic stable intramedullary nail fixation has become established as an acceptable method of treatment for diaphyseal fractures of both forearm bones in the paediatric population. It is considered safe, minimally invasive and does not compromise physeal growth. We report a case of delayed rupture of extensor pollicis longus due to attrition over the sharp edges of a protruding nail end after elastic stable intramedullary nailing of a paediatric radial diaphyseal fracture.

  10. Treatment of pediatric femoral shaft fractures by stainless steel and titanium elastic nail system: A randomized comparative trial.

    Science.gov (United States)

    Gyaneshwar, Tank; Nitesh, Rustagi; Sagar, Tomar; Pranav, Kothiyal; Rustagi, Nitesh

    2016-08-01

    in titanium group but five in stainless steel group. Majority of paediatric femoral shaft fractures are now treated operatively by elastic stable intramedullary nails. Operative intervention results in a shorter hospital stay and has economic and social benefits over conservative treatment. The cost of stainless steel nail is one third the cost of titanium nail. However, the clinico-radiological results are not significantly different between titanium and stainless steel nails at one year follow-up as observed by our study.

  11. New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study

    Directory of Open Access Journals (Sweden)

    Emmanuel D. Eisenstein

    2016-01-01

    Full Text Available Introduction. Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods. We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results. Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion. Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice.

  12. Treatment of humeral shaft fractures with antegrade intramedullary locking nail.

    Science.gov (United States)

    Tsourvakas, Stefanos; Alexandropoulos, Christos; Papachristos, Ioannis; Tsakoumis, Grigorios; Ameridis, Nikolaos

    2011-12-01

    Antegrade interlocked humeral nailing for stabilization of humeral fractures was introduced many years ago, and studies on this method in the orthopedic literature have shown mixed results. The purpose of this investigation was to document the clinical outcome and complications associated with the use of an antegrade intramedullary nail (T2, Stryker) for the humeral fractures. Between 2005 and 2008, 52 fractures of the humeral shaft were treated operatively with this intramedullary nail in our department. Eight patients were polytraumatized, and four patients had an open fracture. The mean age of patients was 51.7 years. Forty-eight patients had an adequate duration of clinical follow-up (a mean of 18 months) for analysis. Complications were recorded, and the time to union was measured. Shoulder and elbow functions were assessed using the Constant Score and the Morrey Score, respectively. Forty-six fractures healed, with a mean time to clinical union of 10.3 weeks. Two patients developed pseudarthroses. There were four adverse events: two proximal screws backed out, one superficial infection at the insertion point, and one fracture at the distal end of the nail. Ninety-one percentage of patients had an excellent or good shoulder function. Five further operations were necessary: two for treatment of pseudarthroses, two for removal the backed out proximal screws, and one wound debridement for superficial infection. Antegrade humeral nailing is a valid therapeutic option for stabilization of humeral shaft fractures. By strictly adhering to the operation technique, the number and the severity of complications can be reduced. When good fracture alignment and stability are obtained, uneventful bone healing with good functional results is the rule.

  13. Comparison of suprapatellar and infrapatellar intramedullary nailing for tibial shaft fractures: a systematic review and meta-analysis.

    Science.gov (United States)

    Yang, Liqing; Sun, Yuefeng; Li, Ge

    2018-06-14

    Optimal surgical approach for tibial shaft fractures remains controversial. We perform a meta-analysis from randomized controlled trials (RCTs) to compare the clinical efficacy and prognosis between infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. PubMed, OVID, Embase, ScienceDirect, and Web of Science were searched up to December 2017 for comparative RCTs involving infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. Primary outcomes were blood loss, visual analog scale (VAS) score, range of motion, Lysholm knee scores, and fluoroscopy times. Secondary outcomes were length of hospital stay and postoperative complications. We assessed statistical heterogeneity for each outcome with the use of a standard χ 2 test and the I 2 statistic. The meta-analysis was undertaken using Stata 14.0. Four RCTs involving 293 participants were included in our study. The present meta-analysis indicated that there were significant differences between infrapatellar and suprapatellar intramedullary nail regarding the total blood loss, VAS scores, Lysholm knee scores, and fluoroscopy times. Suprapatellar intramedullary nailing could significantly reduce total blood loss, postoperative knee pain, and fluoroscopy times compared to infrapatellar approach. Additionally, it was associated with an improved Lysholm knee scores. High-quality RCTs were still required for further investigation.

  14. Elastic stable intramedullary nailing of femoral shaft fractures in children: Particularities and results at Sylvanus Olympio teaching hospital of Lomé, Togo

    Directory of Open Access Journals (Sweden)

    Akakpo-Numado Gamedzi Komlatsè

    2014-01-01

    Full Text Available Introduction: The elastic stable intramedullary nailing (ESIN presently seems the best technique in the surgical treatment of femoral shaft fractures (FSF in >6-year-old children. We hereby report technical difficulties and therapeutic results after our first 8 years of experience. Patients and Methods: It′s a retrospective study over a period of 8 years from January 2005 to December 2012 in the Paediatric Surgery Department of Sylvanus Olympio Teaching Hospital of Lomé. Indications, technical particularities and results were studied. Results: There were 32 patients, 17 were boys and 15 were girls, with a mean age of 11 years old. The mean time to surgery was 21 days (range: 14 and 51 days. A callus was always removed before reduction. The osteosynthesis was stable in 22 cases, but in 10 others, it had been completed with a cast immobilisation. The operation needed a blood transfusion in 18 cases. With a mean follow-up of 3.5 years, the results were excellent in 29 patients (90.63% and good in 3 patients (9.37%. Conclusion: Although undertaking an ESIN can be difficult, due to the lack of adequate equipment the procedure produces satisfactory outcome.

  15. Nonunions of the distal tibia treated by reamed intramedullary nailing

    NARCIS (Netherlands)

    Richmond, Jeffrey; Colleran, Kevin; Borens, Olivier; Kloen, Peter; Helfet, David L.

    2004-01-01

    The purpose of this study is to determine the efficacy of reamed intramedullary nailing in the treatment of nonunions of the distal one-fourth of the tibia. Nonunions of the distal tibia are particularly difficult to treat given the short distal segment, the proximity to the ankle joint, and the

  16. Efficacy and Safety of Interlocked Intramedullary Nailing for Open Fracture Shaft of Tibia

    International Nuclear Information System (INIS)

    Ahmad, N.; Awan, A. S.; Sultan, S.; Saifullah, K.; Afridi, S. A.; Afridi, S. K.; Lodhi, F. S.

    2016-01-01

    Background: Due to increasing population and changing human habits the number of accidents and high energy trauma is rising. Management of open fracture tibia is a complex problem and is a challenge for both orthopaedic and plastic surgeons. The study was carried out to ascertain the efficacy and safety of interlocked intra-medullary nailing for open shaft tibial fractures in patients presenting at or after 24 hr of injury. Methods: In this descriptive case series, over a period of 6 moths, 163 consecutive cases of open fracture of tibial shaft were reviewed in terms of clinical profile, time of presentation, and gender distribution. Results: In this study mean age was 30±0.02 years. Males comprised 85 percent of study population while 15 percent were females. Gustilo-I type fracture and Gustilo-II type fracture was diagnosed in 90 percent and 10 percent patients respectively. Thirty three percent patients had wound infection while fracture union was found in 15 percent cases. Moreover interlocked intramedullary nailing for open fracture shaft of tibia was safe in 80 percent patients while this procedure was effective in 85 percent. Conclusion: Un-reamed, interlocked intra-medullary nailing may be considered as a suitable option for treatment of open fractures of tibia. (author)

  17. A prospective, randomised trial comparing closed intramedullary nailing with percutaneous plating in the treatment of distal metaphyseal fractures of the tibia.

    Science.gov (United States)

    Guo, J J; Tang, N; Yang, H L; Tang, T S

    2010-07-01

    We compared the outcome of closed intramedullary nailing with minimally invasive plate osteosynthesis using a percutaneous locked compression plate in patients with a distal metaphyseal fracture in a prospective study. A total of 85 patients were randomised to operative stabilisation either by a closed intramedullary nail (44) or by minimally invasive osteosynthesis with a compression plate (41). Pre-operative variables included the patients' age and the side and pattern of the fracture. Peri-operative variables were the operating time and the radiation time. Postoperative variables were wound problems, the time to union of the fracture, the functional American Orthopaedic Foot and Ankle surgery score and removal of hardware. We found no significant difference in the pre-operative variables or in the time to union in the two groups. However, the mean radiation time and operating time were significantly longer in the locked compression plate group (3.0 vs 2.12 minutes, p fractures had united. Patients who had intramedullary nailing had a higher mean pain score (40 = no pain, 0 = severe pain), [corrected] but better function, alignment and total American Orthopaedic Foot and Ankle surgery scores, although the differences were not statistically significant (p = 0.234, p = 0.157, p = 0.897, p = 0.177 respectively). Three (6.8%) patients in the intramedullary nailing group and six (14.6%) in the locked compression plate group showed delayed wound healing, and 37 (84.1%) in the former group and 38 (92.7%) in the latter group expressed a wish to have the implant removed. We conclude that both closed intramedullary nailing and a percutaneous locked compression plate can be used safely to treat Orthopaedic Trauma Association type-43A distal metaphyseal fractures of the tibia. However, closed intramedullary nailing has the advantage of a shorter operating and radiation time and easier removal of the implant. We therefore prefer closed intramedullary nailing for patients with

  18. Staged protocol for the treatment of chronic femoral shaft osteomyelitis with Ilizarov's technique followed by the use of intramedullary locked nail

    Directory of Open Access Journals (Sweden)

    Po-Hsin Chou

    2017-06-01

    Conclusion: In the treatment of chronic femur osteomyelitis, the staged protocol of Ilizarov distraction osteogenesis followed by intramedullary nailing was safe and successful, and allowed for union, realignment, reorientation, and leg-length restoration. With regard to the soft tissue, this technique provides a unique type of reconstructive closure for infected wounds. It is suggested that the staged protocol is reliable in providing successful simultaneous reconstruction for bone and soft tissue defects without flap coverage.

  19. Comparative analysis of uniplanar external fixator and retrograde intramedullary nailing for ankle arthrodesis in diabetic Charcot′s neuroarthropathy

    Directory of Open Access Journals (Sweden)

    Nakul S Shah

    2011-01-01

    Results: All five (100% patients treated by intramedullary nailing achieved radiological union on an average follow-up of 16 weeks. The external fixation group had significantly higher rate of complications with one amputation, four non unions (66.7% and a delayed union which went on to full osseous union. Conclusion: The retrograde intramedullary nailing for tibio-talar arthrodesis in Charcot′s neuroarthropathy yielded significantly better outcomes as compared to the use of uniplanar external fixator.

  20. Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty.

    Science.gov (United States)

    Maderbacher, Günther; Matussek, Jan; Keshmiri, Armin; Greimel, Felix; Baier, Clemens; Grifka, Joachim; Maderbacher, Hermann

    2018-02-17

    Intramedullary rods are widely used to align the distal femoral cut in total knee arthroplasty. We hypothesised that both coronal (varus/valgus) and sagittal (extension/flexion) cutting plane are affected by rotational changes of intramedullary femoral alignment guides. Distal femoral cuts using intramedullary alignment rods were simulated by means of a computer-aided engineering software in 4°, 6°, 8°, 10°, and 12° of valgus in relation to the femoral anatomical axis and 4° extension, neutral, as well as 4°, 8°, and 12° of flexion in relation to the femoral mechanical axis. This reflects the different angles between anatomical and mechanical axis in coronal and sagittal planes. To assess the influence of rotation of the alignment guide on the effective distal femoral cutting plane, all combinations were simulated with the rod gradually aligned from 40° of external to 40° of internal rotation. Rotational changes of the distal femoral alignment guides affect both the coronal and sagittal cutting planes. When alignment rods are intruded neutrally with regards to sagittal alignment, external rotation causes flexion, while internal rotation causes extension of the sagittal cutting plane. Simultaneously the coronal effect (valgus) decreases resulting in an increased varus of the cutting plane. However, when alignment rods are intruded in extension or flexion partly contradictory effects are observed. Generally the effect increases with the degree of valgus preset, rotation and flexion. As incorrect rotation of intramedullary alignment guides for distal femoral cuts causes significant cutting errors, exact rotational alignment is crucial. Coronal cutting errors in the distal femoral plane might result in overall leg malalignment, asymmetric extension gaps and subsequent sagittal cutting errors.

  1. The treatment of nonisthmal femoral shaft nonunions with im nail exchange versus augmentation plating.

    Science.gov (United States)

    Park, Jin; Kim, Sul Gee; Yoon, Han Kook; Yang, Kyu Hyun

    2010-02-01

    The purpose of this study was to compare the results between exchange nailing (EN) and augmentation plating (AP) with a nail left in situ for nonisthmal femoral shaft nonunion after femoral nailing. : Retrospective data analysis, November 1996-March 2006. A level I trauma center. Eighteen patients with 18 nonisthmal femoral nonunions. Seven patients with 7 fractures treated for nonisthmal femoral shaft nonunions after femoral nailing with EN and 11 patients with 11 fractures treated for nonisthmal femoral shaft nonunions after nailing with AP combined with bone grafting. Union and complications. Five nonunions in the EN group failed to achieve union (72% failure rate), whereas all 11 pseudarthroses in the AP group obtained osseous union. Fisher exact test showed a higher nonunion rate of EN compared with AP for nonisthmal femoral shaft nonunion (odds ratio, 6.5; P = 0.002). AP with autogenous bone grafting may be a better option than EN for nonisthmal femoral nonunions.

  2. Short-term outcome of patients with closed comminuted femoral ...

    African Journals Online (AJOL)

    Short-term outcome of patients with closed comminuted femoral shaft fracture treated with locking intramedullary sign nail at Muhimbili Orthopaedic Institute in Tanzania. Billy T. Haonga, Felix S. Mrita, Edmundo E. Ndalama, Jackline E. Makupa ...

  3. Comparative endurance testing of the Biomet Matthews Nail and the Dynamic Compression Screw, in simulated condylar and supracondylar femoral fractures

    Directory of Open Access Journals (Sweden)

    Davies Benjamin M

    2008-01-01

    Full Text Available Abstract Background The dynamic compression screw is a plate and screws implant used to treat fractures of the distal femur. The Biomet Matthews Nail is a new retrograde intramedullary nail designed as an alternative surgical option to treat these fractures. The objective of this study was to assess the comparative endurance of both devices. Method The dynamic compression screw (DCS and Biomet Matthews Nail (BMN were implanted into composite femurs, which were subsequently cyclically loaded using a materials testing machine. Simulated fractures were applied to each femur prior to the application of load. Either a Y type fracture or a transverse osteotomy was prepared on each composite femur using a jig to enable consistent positioning of cuts. Results The Biomet Matthews Nail demonstrated a greater endurance limit load over the dynamic compression screw in both fracture configurations. Conclusion The distal locking screws pass through the Biomet Matthews Nail in a unique "cruciate" orientation. This allows for greater purchase in the bone of the femoral condyle and potentially improves the stability of the fracture fixation. As these fractures are usually in weak osteoporotic bone, the Biomet Matthews Nail represents a favourable surgical option in these patients.

  4. Semiextended approach for intramedullary nailing via a patellar eversion technique for tibial-shaft fractures: Evaluation of the patellofemoral joint.

    Science.gov (United States)

    Yasuda, Tomohiro; Obara, Shu; Hayashi, Junji; Arai, Masayuki; Sato, Kaoru

    2017-06-01

    Intramedullary nail fixation is a common treatment for tibial-shaft fractures, and it offers a better functional prognosis than other conservative treatments. Currently, the primary approach employed during intramedullary nail insertion is the semiextended position is the suprapatellar approach, which involves a vertical incision of the quadriceps tendon Damage to the patellofemoral joint cartilage has been highlighted as a drawback associated with this approach. To avoid this issue, we perform surgery using the patellar eversion technique and a soft sleeve. This method allows the articular surface to be monitored during intramedullary nail insertion. We arthroscopically assessed the effect of this technique on patellofemoral joint cartilage. The patellar eversion technique allows a direct view and protection of the patellofemoral joint without affecting the patella. Thus, damage to the patellofemoral joint cartilage can be avoided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Do biodegradable magnesium alloy intramedullary interlocking nails prematurely lose fixation stability in the treatment of tibial fracture? A numerical simulation.

    Science.gov (United States)

    Wang, Haosen; Hao, Zhixiu; Wen, Shizhu

    2017-01-01

    Intramedullary interlocking nailing is an effective technique used to treat long bone fractures. Recently, biodegradable metals have drawn increased attention as an intramedullary interlocking nailing material. In this study, numerical simulations were implemented to determine whether the degradation rate of magnesium alloy makes it a suitable material for manufacturing biodegradable intramedullary interlocking nails. Mechano-regulatory and bone-remodeling models were used to simulate the fracture healing process, and a surface corrosion model was used to simulate intramedullary rod degradation. The results showed that magnesium alloy intramedullary rods exhibited a satisfactory degradation rate; the fracture healed and callus enhancement was observed before complete dissolution of the intramedullary rod. Delayed magnesium degradation (using surface coating techniques) did not confer a significant advantage over the non-delayed degradation process; immediate degradation also achieved satisfactory healing outcomes. However, delayed degradation had no negative effect on callus enhancement, as it did not cause signs of stress shielding. To avoid risks of individual differences such as delayed union, delayed degradation is recommended. Although the magnesium intramedullary rod did not demonstrate rapid degradation, its ability to provide high fixation stiffness to achieve earlier load bearing was inferior to that of the conventional titanium alloy and stainless steel rods. Therefore, light physiological loads should be ensured during the early stages of healing to achieve bony healing; otherwise, with increased loading and degraded intramedullary rods, the fracture may ultimately fail to heal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Effects of third fragment size and displacement on non-union of femoral shaft fractures after locking for intramedullary nailing.

    Science.gov (United States)

    Lee, J R; Kim, H-J; Lee, K-B

    2016-04-01

    femoral shaft fractures with fragments 8cm or longer or when the displacement in the proximal area is 20mm or greater and 10mm or greater in the distal area during the intramedullary nailing procedure. Regarding union rate, the degree of displacement has more influence than the third fragment size in femoral shaft fractures. IV, retrospective cohort study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. A new mini-invasive technique in treating pediatric diaphyseal forearm fractures by bioabsorbable elastic stable intramedullary nailing: a preliminary technical report.

    Science.gov (United States)

    Sinikumpu, J-J; Keränen, J; Haltia, A-M; Serlo, W; Merikanto, J

    2013-01-01

    Operative treatment is often indicated in unstable pediatric diaphyseal forearm fractures. Recently minimally invasive reduction and elastic stable intramedullary nailing have been of increasing interest, instead of open reduction and internal fixation with plates. There are several disadvantages of metallic intramedullary implants, such as soft-tissue irritation and a risk of disturbing later imaging. Thus, they are generally removed in later operations. We aimed to develop a new technique to stabilize pediatric forearm fractures by the bioabsorbable intramedullary nailing. We developed a new, two-stage mini-invasive surgical technique to stabilize the unstable diaphyseal fractures in children. The procedure is bioabsorbable elastic stable intramedullary nailing. Ultra-high-strength bioabsorbable intramedullary nails of poly(lactide-co-glycolide) were manufactured for our purpose. The material has been widely proven to be biocompatible and stable enough for fracture treatment as screws and pins. We have used the new technique in the unstable both-bone diaphyseal forearm fractures in children between the ages of 5 and 15 years. We report the technique and our clinical experience in the series of those three cases that have been followed up for at least 12 months. The present series has been randomized for the procedure instead for titanium elastic stable intramedullary nailing, and the series represents a part of ongoing randomized trial. The reported cases operated by the new technique referred good union in the fractured bones and acceptable alignment in the follow-up. Removal of the implants was not required. No troubles with the procedure or implant per se were noticed, indicating good feasibility. One high-energy refracture occurred half year after the primary trauma. Traditional titanium implants were used to control the refracture. We report our preliminary experience of a new surgical mini-invasive procedure to stabilize the unstable pediatric forearm shaft

  8. Staged Custom, Intramedullary Antibiotic Spacers for Severe Segmental Bone Loss in Infected Total Hip Arthroplasty

    Directory of Open Access Journals (Sweden)

    Atul F. Kamath

    2011-01-01

    Full Text Available Introduction. Total hip arthroplasty (THA infections with severe bone loss pose significant reconstructive challenges. We present our experience with two-stage hip reimplantation using an intramedullary, antibiotic-impregnated nail. Methods. Three patients with infected THA with severe proximal femoral bone loss (Mallory type IIIB or greater were treated using a custom antibiotic spacer. Clinical outcomes and any complications were recorded. Average followup was 49 months from final reimplantation. Results. Mean age at spacer placement (stage 1 was 53 years. The mean Harris Hip Score at final followup was 80. Two patients had asymptomatic heterotopic ossification, and one patient had a 2 cm leg-length discrepancy. Conclusions. A custom intramedullary nail antibiotic spacer is a reliable option in the staged management of the infected THA with severe proximal femoral bone loss. Benefits of this technique include limb salvage with maintenance of leg length, soft tissue tension, and functional status.

  9. Intramedullary femoral nailing through the trochanteric fossa versus greater trochanter tip : a randomized controlled study with in-depth functional outcome results

    NARCIS (Netherlands)

    Moein, C. M. Ansari; ten Duis, H. J.; Oey, P. L.; de Kort, G. A. P.; van der Meulen, W.; van der Werken, Chr

    2011-01-01

    In a level 1 university trauma center, an explorative randomized controlled study was performed to compare soft tissue damage and functional outcome after antegrade femoral nailing through a trochanteric fossa (also known as piriform fossa) entry point to a greater trochanter entry point in patients

  10. Treatment for Trochanteric Fracture of the Femur with Short Femoral Nail: A Comparison between the Asian Intramedullary Hip Screw (IMHS) and the Conventional IMHS.

    Science.gov (United States)

    Kawaji, Hidemi; Uematsu, Takuya; Oba, Ryosuke; Satake, Yoshihiko; Hoshikawa, Naoya; Takai, Shinro

    2016-01-01

    We usually use short femoral nails for the treatment of trochanteric fracture of the femur. In this retrospective study, we investigated and compared the clinical results of the conventional intramedullary hip screw (IMHS) and the Asian IMHS, which is a redesigned version of the former. The subjects were 42 patients; 21 treated with the Asian IMHS and 21 were treated with the conventional IMHS. From the clinical records, we retrospectively investigated the patients' age, sex, in-hospital waiting period for operation, operating time, intraoperative blood loss, walking ability before fracture and at discharge, and complication pertaining to the operation. The 21 patients (4 men and 17 women) receiving the Asian IMHS and the 21 patients (5 men and 16 women) receiving the conventional IMHS did not differ significantly in mean age, sex ratio, preoperative waiting period, mean postoperative hospital stay, mean operation time, or mean intraoperative blood loss. Among patients receiving the Asian IMHS, the complications of intraoperative fractures of the femur developed in 3 patients and breakage of the implant occurred in 1 patient. No complications occurred in patients receiving the conventional IMHS. Compared with the conventional IMHS, the Asian IMHS is smaller, has increased variations in the shaft/neck angle of the lag screw, and has a titanium-alloy construction, allowing magnetic resonance imaging. The intraoperative fracture may have occurred because of the configuration of the distal interlocking screw in the Asian IMHS. Breakage of the implant likely occurred because the nail was too small in diameter, and too short in length for the unstable AO 31-A3 fracture. If careful attention is paid to the configuration of its distal interlocking screw intraoperatively and a nail of appropriate size is selected, the Asian IMHS is better suited than the conventional IMHS for treating Japanese patients, who generally have a small physique, because of its many variations in

  11. Advanced interlocking systems to improve heavy-load-bearing characteristics of flexible intramedullary nailing

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Leopold, E-mail: leopold.berger@tuwien.ac.at [Institute of Building Construction and Technology, TU Wien, Karlsplatz 13/206-4, 1040 Vienna (Austria); Eichler, Johannes [Department of Orthopedics and Orthopedic Surgery, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz (Austria); Ryll, E. Jonathan S. [Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital Muenster, Westphalian-Wilhelms University, Muenster (Germany); Fischerauer, Stefan [Department of Traumatology, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz (Austria); Raschke, Michael J. [Department of Trauma-, Hand- and Reconstructive Surgery, University Hospital Muenster, Westphalian-Wilhelms University, Muenster (Germany); Kolbitsch, Andreas [Institute of Building Construction and Technology, TU Wien, Karlsplatz 13/206-4, 1040 Vienna (Austria); Castellani, Christoph [Department of Pediatric and Adolescence Surgery, Medical University of Graz, Auenbruggerplatz 34, 8036 Graz (Austria); Weinberg, Annelie-Martina [Department of Orthopedics and Orthopedic Surgery, Medical University of Graz, Auenbruggerplatz 5/6, 8036 Graz (Austria)

    2016-11-01

    Flexible intramedullary nailing (FIN) is a minimally invasive and widespread standard method for osteosynthesis of pediatric long bone fractures. In the case of unstable fractures of the lower extremity, interlocking systems need to be used to prevent axial shortening and subsequent perforation of the nail at its insertion site. In the present study, four different screw-fixed interlocking systems for FINs (Hofer TwinPlug with two 3-mm titanium interlocking screws, Hofer FixPlug with 3-mm titanium interlocking screw, Hofer Plug with 3.5-mm titanium interlocking screw, and Hofer Plug with 3-mm titanium interlocking screw) in comparison with the commonly used Ender stainless steel nails (locked with 3.5-mm screw) were experimentally investigated in cadaveric lamb tibiae, regarding their load characteristics and failure modes in the case of heavy loading. The specimens were subjected to sequential axial cyclic loading of 5000cycles with stepwise increase of the load amplitude until failure. Migration of locking screws and internal damage of bone tissue was quantified by micro-computed tomography (CT) imaging. Ender nails failed on average at a peak load of 800 N, TwinPlugs at 1367 N, FixPlugs at 1222 N, Plugs 3.5mm at 1225 N and Plugs 3.0mm at 971 N. TwinPlugs, FixPlugs, and Plugs 3.5mm failed in a slow manner over several hundred loading cycles, whereas Ender nails and Plugs 3.0mm exhibited abrupt failure without any prior indication. Our results confirm that axial stability of FIN can be further improved by screw-fixed plugs by simultaneously avoiding shortcomings of an eye-locked system, which the Ender nails are. Considering biomechanical results, plug interlocking systems with 3.5-mm screws should be favored over conventional Ender nails and plugs with 3-mm screws. - Highlights: • Locked flexible intramedullary nails in lamb tibiae were cyclically loaded. • Strongly different failure modes of locking systems were detected. • Novel screw-fixed plugs are

  12. Intramedullary nailing of proximal and distal one-third tibial shaft fractures with intraoperative two-pin external fixation.

    Science.gov (United States)

    Wysocki, Robert W; Kapotas, James S; Virkus, Walter W

    2009-04-01

    Fractures of the proximal and distal one thirds of the tibial shaft have historically higher malunion rates than those of the midshaft. This retrospective case series evaluates the postoperative radiographic outcome of intramedullary nailing of proximal and distal one-third tibial shaft fractures using intraoperative two-pin external fixation, often referred to as traveling traction. Between 2000 and 2005, 15 consecutive patients with proximal third and 27 consecutive patients with distal third displaced extra-articular fractures of the tibia were treated with statically locked intramedullary nailing and supplementary intraoperative two-pin rectangular frame external fixation. The external fixation was removed once the proximal and distal locking screws were in place. The alignment of the fractures was determined using standard postoperative anteroposterior and lateral radiographs. Postoperatively, 14 of 15 patients with proximal fractures and 25 of 27 patients with distal fractures had less than 5 degrees of angular deformity in both the coronal and sagittal planes and less than 1 cm shortening. Statically locked intramedullary nailing with simultaneous intraoperative traveling traction external fixation as treatment for proximal and distal one-third extra-articular tibial shaft fractures is successful in achieving a high rate of acceptable postoperative alignment.

  13. Intramedullary nailing of femoral shaft fractures in polytraumatized patients. a longitudinal, prospective and observational study of the procedure-related impact on cardiopulmonary- and inflammatory responses

    Directory of Open Access Journals (Sweden)

    Husebye Elisabeth E

    2012-01-01

    Full Text Available Abstract Background Early intramedullary nailing (IMN of long bone fractures in severely injured patients has been evaluated as beneficial, but has also been associated with increased inflammation, multi organ failure (MOF and morbidity. This study was initiated to evaluate the impact of primary femoral IMN on coagulation-, fibrinolysis-, inflammatory- and cardiopulmonary responses in polytraumatized patients. Methods Twelve adult polytraumatized patients with femoral shaft fractures were included. Serial blood samples were collected to evaluate coagulation-, fibrinolytic-, and cytokine activation in arterial blood. A flow-directed pulmonary artery (PA catheter was inserted prior to IMN. Cardiopulmonary function parameters were recorded peri- and postoperatively. The clinical course of the patients and complications were monitored and recorded daily. Results Mean Injury Severity Score (ISS was 31 ± 2.6. No procedure-related effect of the primary IMN on coagulation- and fibrinolysis activation was evident. Tumor necrosis factor alpha (TNF-α increased significantly from 6 hours post procedure to peak levels on the third postoperative day. Interleukin-6 (IL-6 increased from the first to the third postoperative day. Interleukin-10 (IL-10 peaked on the first postoperative day. A procedure-related transient hemodynamic response was observed on indexed pulmonary vascular resistance (PVRI two hours post procedure. 11/12 patients developed systemic inflammatory response syndrome (SIRS, 7/12 pneumonia, 3/12 acute lung injury (ALI, 3/12 adult respiratory distress syndrome (ARDS, 3/12 sepsis, 0/12 wound infection. Conclusion In the polytraumatized patients with femoral shaft fractures operated with primary IMN we observed a substantial response related to the initial trauma. We could not demonstrate any major additional IMN-related impact on the inflammatory responses or on the cardiopulmonary function parameters. These results have to be interpreted

  14. A-Frame free Vascularized Fibular Graft and Femoral Lengthening for Osteosarcoma Pediatric Patients.

    Science.gov (United States)

    Cashin, Megan; Coombs, Christopher; Torode, Ian

    2018-02-01

    Pediatric limb reconstruction after resection of a malignant tumor presents specific challenges. Multiple surgical techniques have been used to treat these patients. This paper describes a staged surgical technique for the reconstruction of large distal femoral defects due to tumor resection in skeletally immature patients. Three pediatric patients with osteosarcoma of the distal femur underwent staged reconstruction. Neoadjuvant chemotherapy was followed by en bloc tumor resection and immediate reconstruction of the distal femoral defect with a vascularized free fibular autograft utilizing a unique A-frame construct combined with intramedullary nail fixation. The second stage was a planned gradual lengthening of the healed construct, over a custom-made magnetically driven expandable intramedullary nail. All patients achieved bony union and satisfactory length with minimal complications. The patients all returned to full, unlimited physical activities. The early results confirm that the described technique is a safe and reliable procedure for the reconstruction of large femoral defects in pediatric patients with osteosarcoma. Level IV-therapeutic.

  15. A comparative study of the therapeutic effect between long and short intramedullary nails in the treatment of intertrochanteric femur fractures in the elderly.

    Science.gov (United States)

    Guo, Xue-Feng; Zhang, Ke-Ming; Fu, Hong-Bo; Cao, Wen; Dong, Qiang

    2015-01-01

    To compare the clinical effects of long vs. short intramedullary nails in the treatment of intertrochanteric fractures in old patients more than 65 years old. A retrospective analysis of 178 cases of intertrochanteric fractures of the femur (AO type A1 and A2) in the elderly was conducted from January 2008 to December 2013. There were 85 males (47.8%) and 93 females (52.2%) with the age of 65e89 (70.2±10.8) years. The patients were treated by closed reduction and long or short intramedullary nail (Gamma 3) fixation. The length of short nail was 180 mm and that for long nail was 320e360 mm. The general data of patients, operation time, intraoperative blood loss, length of hospital stay, preoperative hemoglobin level, blood transfusion rate, postoperative periprosthetic fractures, infections, complications, etc were carefully recorded. There were 76 cases (42.7%) in the long intramedullary nail group and 102 cases (57.3%) in the short nail group. All the cases were followed up for 12e48 (21.3±6.8) months, during which there were 21 deaths (11.8%), mean (13.8±6.9) months after operation. The intraoperative blood loss was (90.7±50.6) ml in short nail group, greatly less than that in long nail group (127.8±85.9) ml (p=0.004). The short nail group also had a significantly shorter operation time (43.5 min±12.3 min vs. 58.5 min±20.3 min, p=0.002) and lower rate of postoperative transfusion (42.3% vs. 56.7%, p=0.041). But the length of hospital stay showed no big differences. After operation, in each group there was 1 case of periprosthetic fracture with a total incidence of 1.1%, 1.3% in long nail group and 0.9% in short nail group. At the end of the follow-up, all patients achieved bony union. The average healing time of the long nail group was (6.5±3.1) months, and the short nail group was (6.8±3.7) months, revealing no significant differences (p=0.09). Postoperative complications showed no great differences either. Both the intramedullary long and short nail

  16. Robotic technique improves entry point alignment for intramedullary nailing of femur fractures compared to the conventional technique: a cadaveric study.

    Science.gov (United States)

    Suero, Eduardo M; Westphal, Ralf; Citak, Musa; Hawi, Nael; Liodakis, Emmanouil; Krettek, Christian; Stuebig, Timo

    2017-08-11

    We aimed to test whether a robotic technique would offer more accurate access to the proximal femoral medullary cavity for insertion of an intramedullary nail compared to the conventional manual technique. The medullary cavity of ten femur specimens was accessed in a conventional fashion using fluoroscopic control. In ten additional femur specimens, ISO-C 3D scans were obtained and a computer program calculated the ideal location of the cavity opening based on the trajectory of the medullary canal. In both techniques, the surgeon opened the cavity using a drill and inserted a radiopaque tube that matched the diameter of the cavity. The mean difference in angle between the proximal opening and the medullary canal in the shaft of the femur was calculated for both groups. Robotic cavity opening was more accurate than the manual technique, with a mean difference in trajectory between the proximal opening and the shaft canal of 2.0° (95% CI 0.6°-3.5°) compared to a mean difference of 4.3° (95% CI 2.11°-6.48°) using the manual technique (P = 0.0218). The robotic technique was more accurate than the manual procedure for identifying the optimal location for opening the medullary canal for insertion of an intramedullary nail. Additional advantages may include a reduction in total radiation exposure, as only one ISO-C 3D scan is needed, as opposed to multiple radiographs when using the manual technique.

  17. [True/Flex intramedullary nailing for forearm shaft fractures. Long-term results].

    Science.gov (United States)

    Trlica, J; Počepcov, I; Kočí, J; Frank, M; Holeček, T; Dědek, T

    2012-01-01

    Presentation of technical experience and the clinical and functional results of intramedullary fixation of forearm shaft fractures. Between January 1994 and December 2009, a total of 96 patients with 144 radial and/or ulnar fractures (ulna, 33; radius,15; both, 48) were treated by nailing (True/Flex®). According to the AO classification there were 22-A, 22-B and 22-C type fractures in 39 (41%), 44 (46%) and 13 (13%).cases, respectively. Of these, 82 (85%) were closed (types: 0, 48; I, 33; II, 1) and 14 (15%) were open (types: I, 13; II, 1; III, 0) fractures. Seventy-eight patients (81%) were followed up and their functional outcomes were evaluated according to the criteria of Anderson et al. The average interval between the operation and final follow-up was 28 months (15 to 96 months) The average time to surgery was 2.2 days (0 to 25 days). Early complications were recorded in 4% of the patients (1x bursitis olecrani; 1x end cup replacement; 1x bending of nails) and late complications in 15% (5x non-union; 2x delay union; 4x bursitis olecrani; 1x ruptured tendon). Bone healing was achieved in 95% of the cases and took on average 16 weeks (7 to 34 weeks). No infection, refracture or synostosis occurred. Primary loss of reduction was recorded in four cases due to distraction in one, bent nails in two and a wrong size of the implant in one; secondary loss of reduction was found in three cases, with two cases of radius shortening and one 10°malrotation. No primary malrotation was recorded, but secondary loss of alignment was seen in the distal part of the radius and the proximal part of the ulna. Functional results according to the Anderson criteria were excellent and good in 87% of the cases. Intramedullary mailing provides good stability to mid- and distal-third shaft fractures of the ulna and mid- and proximalthird shaft fractures of the radius, particularly in AO type A and type B fractures. The technical aspects of the method are analysed in detail in this paper

  18. Chlorhexidine-releasing implant coating on intramedullary nail reduces infection in a rat model

    Directory of Open Access Journals (Sweden)

    SM Shiels

    2018-03-01

    Full Text Available The use of internal intramedullary nails for long bone fracture fixation is a common practice among surgeons. Bacteria naturally attach to these devices, increasing the risk for wound infection, which can result in non- or malunion, additional surgical procedures and extended hospital stays. Intramedullary nail surface properties can be modified to reduce bacterial colonisation and potentially infectious complications. In the current study, a coating combining a non-fouling property with leaching chlorhexidine for orthopaedic implantation was tested. Coating stability and chlorhexidine release were evaluated in vitro. Using a rat model of intramedullary fixation and infection, the effect of the coating on microbial colonisation and fracture healing was evaluated in vivo by quantitative microbiology, micro-computed tomography, plain radiography, three-point bending and/or histology. Low dose systemic cefazolin was administered to increase the similarities to clinical practice, without overshadowing the effect of the anti-infective coating. When introduced into a contaminated wound, the non-fouling chlorhexidine-coated implant reduced the overall bacteria colonisation within the bone and on the implant, reduced the osteolysis and increased the radiographic union, confirming its potential for reducing complications in wounds at high risk of infection. However, when implanted into a sterile wound, non-union increased. Further studies are required to best optimise the anti-microbial effectiveness, while not sacrificing fracture union.

  19. Continuous decompression with intramedullary nailing for the treatment of unicameral bone cysts.

    Science.gov (United States)

    Masquijo, Julio Javier; Baroni, Eduardo; Miscione, Horacio

    2008-08-01

    To evaluate the efficacy of decompression of unicameral bone cysts (UBCs) of the long bones with intramedullary nailing and to compare responses to treatment according to location. We evaluated 48 consecutive patients treated between January 1988 and June 2000. Mean age was 10.3 years. Mean follow-up was 9.8 years. Evaluation was performed according to the radiographic criteria of Capanna. UBCs were located in the proximal humerus (n = 24), humeral shaft (n = 2), proximal femur (n = 19), distal tibia (n = 2) and fibula (n = 1). A total of 62.5% presented a pathological fracture. Successful results were observed in 89.5% (26 total healing, 17 healing with residual radiolucent areas), and there were four recurrences and, in one case, no response to treatment. There was more healing in the humerus than in the femur (92.3% versus 84.2%), and more tendency to restitution ad integrum, although the difference was not statistically significant (P = 0.1499). Intramedullary nailing is a minimally invasive method, which permits early stability and decompresses the cyst allowing healing. Significant differences were not observed among results from different locations.

  20. Nonunion of the humerus following intramedullary nailing treated by Ilizarov hybrid fixation.

    Science.gov (United States)

    Raschke, M; Khodadadyan, C; Maitino, P D; Hoffmann, R; Südkamp, N P

    1998-02-01

    A case of a posttraumatic humeral shaft nonunion, after intramedullary stabilization with a Seidel nail, is presented. Severe osteoporosis, an oligotrophic nonunion, subclinical infection, and adhesive capsulitis of the glenohumeral joint were present. Due to the subclinical infection and severe osteoporosis, other major invasive therapeutic options such as intramedullary nailing or compression plating and bone grafting were not applicable. Nonoperative treatment was also not indicated secondary to the pain and disability present. External fixation with the Ilizarov hybrid fixator seemed to offer a minimally invasive treatment modality without the need of additional bone grafting. After fourteen weeks of "callus massage," consisting of closed alternating compression and distraction with an Ilizarov hybrid fixator, osseous consolidation was achieved. Eight months after Ilizarov treatment the patient had returned to work as a mechanic. At the one-year follow-up examination, the patient presented pain free and with near normal shoulder and elbow motion, with stable osseous consolidation of the humerus. In some cases of nonunion of the humerus shaft, when standard treatment options are not recommended, external fixation with an Ilizarov hybrid fixator may offer a salvage procedure with a successful clinical outcome.

  1. Titanium elastic nailing in pediatric femoral diaphyseal fractures

    Directory of Open Access Journals (Sweden)

    Singh Roop

    2006-01-01

    Full Text Available Background: The need for operative fixation of pediatric femoral fractures is increasingly being recognised in the present decade. The conventional traction and casting method for management of pediatric femoral fractures is giving way for the operative stabilisation of the fracture. Methods : Thirty five pediatric patients in age group 6-14 years with diaphyseal femoral fractures were stabilised with two titanium nails. Patients were followed up clinically and radiologically for two years. The final results were evaluated using the criteria of Flynn et al. Technical problems and complications associated with the procedure were also analysed. Results : Overall results observed were excellent in 25, satisfactory in 8 and poor in 2 patients. Hospital time averaged 12.30 days in the series. All the fractures healed with an average time to union of 9.6 (6-14.4 weeks. Return to school was early with an average of 7.8 weeks. The soft tissue discomfort near the knee produced by the nails ends was the most common problem encountered. Shortening was observed in three cases and restriction of knee flexion in 5 patients. There was no delayed union, infection or refractures. Per operative technical problems included failure of closed reduction in 2 cases and cork screwing of nails in one case. Conclusion : We believe that with proper operative technique and aftercare TENs may prove to be an ideal implant for pediatric femoral fracture fixation. The most of the complication associated with the procedure are infact features of inexact technique and can be eliminated by strictly adhering to the basic principles and technical aspects.

  2. Comparison and analysis of reoperations in two different treatment protocols for trochanteric hip fractures - postoperative technical complications with dynamic hip screw, intramedullary nail and Medoff sliding plate.

    Science.gov (United States)

    Paulsson, Johnny; Stig, Josefine Corin; Olsson, Ola

    2017-08-24

    In treatment of unstable trochanteric fractures dynamic hip screw and Medoff sliding plate devices are designed to allow secondary fracture impaction, whereas intramedullary nails aim to maintain fracture alignment. Different treatment protocols are used by two similar Swedish regional emergency care hospitals. Dynamic hip screw is used for fractures considered as stable within the respective treatment protocol, whereas one treatment protocol (Medoff sliding plate/dynamic hip screw) uses biaxial Medoff sliding plate for unstable pertrochanteric fractures and uniaxial Medoff sliding plate for subtrochanteric fractures, the second (intramedullary nail/dynamic hip screw) uses intramedullary nail for subtrochanteric fractures and for pertrochanteric fractures with intertrochanteric comminution or subtrochanteric extension. All orthopedic surgeries are registered in a regional database. All consecutive trochanteric fracture operations during 2011-2012 (n = 856) and subsequent technical reoperations (n = 40) were derived from the database. Reoperations were analysed and classified into the categories adjustment (percutaneous removal of the locking screw of the Medoff sliding plate or the intramedullary nail, followed by fracture healing) or minor, intermediate (reosteosynthesis) or major (hip joint replacement, Girdlestone or persistent nonunion) technical complications. The relative risk of intermediate or major technical complications was 4.2 (1.2-14) times higher in unstable pertrochanteric fractures and 4.6 (1.1-19) times higher in subtrochanteric fractures with treatment protocol: intramedullary nail/dynamic hip screw, compared to treatment protocol: Medoff sliding plate/dynamic hip screw. Overall rates of intermediate and major technical complications in unstable pertrochanteric and subtrochanteric fractures were with biaxial Medoff sliding plate 0.68%, with uniaxial Medoff sliding plate 1.4%, with dynamic hip screw 3.4% and with intramedullary nail 7.2%. The

  3. THE RESULT OF INTRAMEDULLARY NAILING WITH BONE GRAFTING OF TIBIA'S PATHOLOGIC FRACTURE

    Directory of Open Access Journals (Sweden)

    V. M. Shapovalov

    2010-01-01

    Full Text Available The authors give the clinical case of successful surgical treatment of patient with tibia's pathologic fracture by intramedullary nailing with bone grafting. The disadvantages of such patients' treatment by plaster immobilization and by some invasive methods like vascular autografting by Ilizarov's method and bone plating were also discussed. The obvious benefits of proposed surgical treatment technique of observed patient category are shown.

  4. Intramedullary nailing appears to be superior in pertrochanteric hip fractures with a detached greater trochanter

    DEFF Research Database (Denmark)

    Palm, Henrik; Lysén, Charlotte; Krasheninnikoff, Michael

    2011-01-01

    In recent years, intramedullary nails (INs) for the treatment of pertrochanteric hip fractures have gained prominence relative to conventional, sliding hip screws (SHSs). There is little empirical background for this development, however. A previous series of ours suggested that the use of SHS wa...

  5. Evaluation of the Superior Gluteal Nerve During Proximal Femoral Nailing

    Directory of Open Access Journals (Sweden)

    Mehmet Sonmez

    2017-05-01

    Full Text Available Aim: The superior gluteal nerve may be compromised during hip surgery. We retrospectively evaluated the patients who underwent proximal femoral nailing for unstable trochanteric fractures in order to investigate the presence of superior gluteal nerve injury and its clinical findings. Material and Method: Twenty five patients (14 women, 11 men were included in the study who had femoral nailing between January 2004 and March 2010 at Hamidiye Sisli Etfal Training and Research Hospital Department of Orthopaedics. Two different types of nails which have similar designs and surgical techniques were used for fracture fixation. Patients who had a history of cerebrovascular disease, electromyography findings of polyneuropathy, or degenerative vertebral disease were excluded from the study. Patients were evaluated clinically and radiologically. Findings related to acute denervation in the gluteus medius muscle and motor unit action potential changes were accepted as signs of superior gluteal nerve injury. Results: Eight patients were using support during walking and three of these patients had positive Trendelenburg sign, but only one patient had acute denervation signs of the superior gluteal nerve. Discussion: Based on the present study the incidence of iatrogenic nerve injury is a rare complication of proximal femoral nailing. Elderly patients, regardless of whether they have nerve injury, may limp and need to use a walking support.

  6. Quality of life after antegrade intramedullary nail fixation of humeral fractures: a survey in a selected cohort of Brazilian patients.

    Science.gov (United States)

    Cocco, Luiz Fernando; Ejnisman, Benno; Belangero, Paulo Santoro; Cohen, Moises; Dos Reis, Fernando Baldy

    2018-01-01

    The treatment of humeral fractures remains controversial. Systematic reviews demonstrate similar results between dynamic compression plating and locked intramedullary nailing in the surgical treatment of these fractures. However, it appears that antegrade intramedullary nailing causes higher residual pain in the shoulder. The proposal of this work is to evaluate through the WORC protocol (Western Ontario Rotator Cuff Index) the consequences in the quality of life of patients submitted to osteosynthesis of the humerus with antegrade locked intramedullary nailing. This work is a cohort retrospective study in addition to the application of a questionnaire for self-rated quality of life with its 05 domains (WORC - Western Ontario Rotator Cuff Index) for patients ( N  = 26) classified in the Trauma Sector of the Department of Orthopedics and Traumatology of the Federal University of São Paulo (DOT/UNIFESP) submitted to Humerus Osteosynthesis with Antegrade Locked Intramedullary Nailing. There was also the inclusion of data related to the time since surgery, age, sex, surgical laterality, dominance among members and work leave, which were not considered in the original protocol. After, the data were statistically assessed to evaluate the association between numerical and categorical variables. The overall WORC score was 82.75 ± 17.00 (Mean ± SD) and was not different considering sex, age and postoperative period. Among the WORC domains, both Work and Sport / Recreation Protocols were the most unfavorable factors in the evaluation of patients. Although not statistically significant, those who had the procedure on the dominant side presented a lower quality of life score than those who had the surgery on the non-dominant side. Although non-significant again, those who were away from work had an overall lower quality of life score than those who were not. The WORC Quality of Life Protocol shows good results for evaluating patients submitted to humerus

  7. Comparison of the reconstruction trochanteric antigrade nail (TAN) with the proximal femoral nail antirotation (PFNA) in the management of reverse oblique intertrochanteric hip fractures.

    Science.gov (United States)

    Makki, Daoud; Matar, Hosam E; Jacob, Nebu; Lipscombe, Stephen; Gudena, Ravindra

    2015-12-01

    Reverse oblique intertrochanteric fractures have unique mechanical characteristics and are often treated with intramedullary implants. We compared the outcomes of the reconstruction trochanteric antegrade nail (TAN) with the proximal femoral nail antirotation (PFNA). Between July 2008 and February 2014, we reviewed all patients with reverse oblique intertrochanteric fractures treated at our hospital. Patients with pathological fractures and those who were treated with other than TAN and PFNA nailing systems were excluded. Preoperative assessment included the Abbreviated mental test score (AMT), the ASA grade, pre-injury mobility and place of residence. Postoperative outcome measures included the type of implant used, time to fracture union, failures of fixation and revision surgeries. Fifty-eight patients were included and divided into two groups based on the treatment: 22 patients treated with TAN and 36 patients treated with PFNA systems. The two groups were well matched with regards to demographics and fracture type. The overall union rate was similar in both groups but the time to union was shorter in the TAN group. There were 8 implant failures in the PFNA (22.2%) group compare to none in the TAN group. Implant failure was associated with the severity of fracture (AO 31.A3.3) but was not related to fracture malreduction or screw position (Tip-apex-distance). Our study suggests that the use of reconstruction system with two screws such as TAN may be more suitable implant for reverse oblique intertrochanteric hip fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. COMPARATIVE STUDY BETWEEN TITANIUM ELASTIC NAILING (TENS AND DYNAMIC COMPRESSION PLATING (DCP IN THE TREATMENT OF FEMORAL DIAPHYSEAL FRACTURES IN CHILDREN

    Directory of Open Access Journals (Sweden)

    Ramasubba Reddy

    2015-08-01

    Full Text Available BACKGROUND : Orthopaedic surgeons have long maintained that all children who have sustained a diaphyseal fracture of femur recover with c onservative treatment, given the excellent remodeling ability of immature bone in children. Angulations, shortenings and malrotations are not always corrected by conservative treatment. Of many surgical options, titanium elastic nailing has been the newer implant which is being used regularly. Although good results have been reported with elastic intramedullary nails, plate fixation continues to be a viable alternative in surgical treatment of femoral shaft fractures. However there are not many studies comp aring the efficiency of titanium elastic nailing and plating for femoral diaphyseal fractures in pediatric age group. AIM : The present study aims to compare the surgical management of diaphyseal fractures of femur in children with Dynamic Compression Plati ng versus Titanium Elastic Nailing. DESIGN : This is a prospective study . MATERIALS AND METHODS : This prospective study was conducted in a tertiary hospital. Patients who presented to the out - patient department and casualty of the hospital with femoral diap hyseal fractures during April 2012 to June 2014 were considered for the study. Subjects fulfilling the predetermined inclusion and exclusion criteria were included in the study. STATISTICAL METHODS : Fisher Exact test, Chi - Square Test, Student t test (Two t ailed, independent . RESULTS : Patients in the age group of 6 - 14 years were considered for the study, Patients were divided into two groups and treated with DCP/TENS. The duration of surgery, hospital stay, and, amount of blood loss was minimal in TENS grou p. Callus was seen early in TENS group. Radiological union was early in TENS group by 2 - 3 weeks. Outcome was better in patients treated with TENS (Excellent - 70%; Satisfactory – 30%; Poor - 0% in comparison to DCP (Excellent - 70%; Satisfactory - 25%; Poor - 5%. CO NCLUSION : TENS

  9. Mechanical failures after fixation with proximal femoral nail and risk factors

    Directory of Open Access Journals (Sweden)

    Koyuncu S

    2015-12-01

    postoperative complications were seen in 27 patients (17.7%. A total of 14 patients (9.2% underwent a revision procedure for mechanical complications.Conclusion: The study results suggest that the quality of fracture reduction is an important factor that affects the revision rate and SWS score in patients with mechanical complications after osteosynthesis with PFN for trochanteric fractures. Keywords: trochanteric hip fracture, proximal femoral nail, fracture reduction, complications, risk factors, intramedullary nail

  10. The clinical application of absorbable intramedullary nail and claw plate on treating multiple rib fractures.

    Science.gov (United States)

    Chai, X; Lin, Q; Ruan, Z; Zheng, J; Zhou, J; Zhang, J

    2013-08-01

    The absorption intramedullary nail and claw plate indications and efficacy were investigated in the treatment of a life-threatening multiple rib fractures. A retrospective analysis of 248 surgically treated rib fracture patients was performed who admitted to our hospital from March 2007 to December 2012. Intramedullary nailing was performed in 28 cases, a claw-type bone plate was fixed in 141 cases, and a combination of both was fixed in 79 cases. All internal fixation patients were clinically cured except 1 patient died 14 days after a massive pulmonary embolism. The patients with flail chest and floating chest wall causing respiratory and circulatory disorders were promptly corrected. Routine follow-up was from 1 to 2 years, displaced fractures were in 2 cases, and there were 11 cases of internal fixation and extraction. Internal fixation is a simple and reliable method for the treatment of multiple rib fractures. Both internal fixation materials have their pros and cons but the claw bone plate is more robust. The actual selection of appropriate treatment options helps to improve the treatment efficacy.

  11. [Clinical application of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nail].

    Science.gov (United States)

    Zhu, Hai-Bing; Wu, Li-Guo; Fang, Zhi-Song; Luo, Cong-Feng; Wang, Qing-Feng; Ma, Yi-Ping; Gao, Hong; Fu, Guo-Hai; Hu, Cheng-Ting

    2012-07-01

    To introduce the clinical method of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nails. From June 2006 to March 2011, 26 patients with distal tibial fracture were treated with interlocking intramedullary nails using blocking screws and rooting technique, included 18 males and 8 females with an average age of 46.2 years old ranging from 24 to 64 years. According to AO classification: 10 cases of type A1, 4 cases of type A2, 8 cases of type B1, 4 cases of type B2. The average distance of the fractures end to the ankle joint was 85 mm ranging from 55 to 125 mm, the mean time between injured and operation was 4.5 days. The patients were evaluated with pain, range of motion, walking. All cases were followed-up for 6 to 22 months (averaged 15 months). According to Iowa ankle joint grading system,the score was improved from preoperative (66.8 +/- 8.2) to postoperative (94.6 +/- 4.8). All fractures had united, and got satisfactory reduction and stable fixation with no complications had happen such as breakage of screw. Fixation with interlocking intramedullary nail using blocking screws and rooting technique in treating distal tibial fracture, is a safe and effective technique for the improvement of stability.

  12. Risk of septic knee following retrograde intramedullary nailing of open and closed femur fractures

    Directory of Open Access Journals (Sweden)

    Halvorson Jason J

    2012-02-01

    Full Text Available Abstract Background One potential complication of retrograde femoral nailing in the treatment of femur fractures is the risk of septic knee. This risk theoretically increases in open fractures as a contaminated fracture site has the potential to seed the instrumentation being passed in and out of the sterile intraarticular starting point. There are few studies examining this potential complication in a relatively commonly practiced technique. Methods All patients who received a retrograde femoral nail for femur fracture between September 1996 and November 2006 at a Level 1 trauma center were retrospectively reviewed. This yielded 143 closed fractures, 38 open fractures and 4 closed fractures with an ipsilateral traumatic knee arthrotomy. Patient follow-up records were reviewed for documentation of septic knee via operative notes, wound culture or knee aspirate data, or the administration of antibiotics for suspected septic knee. Results No evidence of septic knee was found in the 185 fractures examined in the dataset. Utilizing the Wilson confidence interval, the rate of septic knee based on our population was no greater than 2%, with that of the open fracture group alone being 9%. Conclusions Based on these results and review of the literature, the risk of septic knee in retrograde femoral nailing of both open and closed femoral shaft fractures appears low but potentially not insignificant. Funding There was no outside source of funding from either industry or other organization for this study.

  13. Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators

    Directory of Open Access Journals (Sweden)

    Kulshrestha Vikas

    2008-01-01

    Full Text Available Background: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail. Materials and Methods: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature. Results: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10, 14 Gustilo type 2 (n=14, and type3 (n=6 cases. 6 cases (20% had clamp site infection, 2 cases (6.7% had deep infection, and in 28 cases (93% the fracture healed and consolidated well. Conclusion: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection.

  14. Case report: AVN of the femoral head five year follow-up of the combination of ipsilateral femoral neck and sub-trochanteric fracture.

    Science.gov (United States)

    Zhang, Wei; Zhu, Feng; Dong, Hanqing; Xu, Yaozeng

    2016-04-01

    To our knowledge, the type of combination of ipsilateral femoral neck and sub-trochanteric fracture is rare. And the long term follow-up is seldom been reported. A 60 year old woman suffered from a traffic accident. We gave her the intramedullary nail treatment for the combination of ipsilateral femoral neck and sub-trochanteric fracture, and the fracture indeed cured after one year and there is no clue of necrosis of the femoral head, but after 5 years, there is an evidence of necrosis of the femoral head. Combination of ipsilateral femoral neck and sub-trochanteric fracture should be kept in mind. Patients with this unusual fracture should be kept under surveillance for longer than might be thought currently to be necessary for there is a possibility of necrosis of the femoral head, even a nondisplaced femoral neck fracture.

  15. The percutaneous use of a pointed reduction clamp during intramedullary nailing of distal third tibial shaft fractures.

    Science.gov (United States)

    Forman, Jordanna M; Urruela, Adriana M; Egol, Kenneth A

    2011-12-01

    The purpose of this retrospective chart and radiographic review is to describe an effective reduction technique during intramedullary nailing of distal metaphyseal tibia fractures with the use of a pointed percutaneous clamp. Between 2007 and 2010, 100 patients who sustained 102 tibia fractures were definitively treated with an intramedullary nail at one of two medical centers. Diaphyseal fractures and injuries with an associated disruption of the distal tibiofibular joint were excluded from our study. A total of 27 patients with 27 distal metaphyseal tibia fractures (OTA types 42-A, 43-A, and 43-B) were included. All 27 patients underwent IM nailing of their fractures with anatomic reduction achieved using a percutaneously placed pointed reduction clamp prior to insertion of the IM implant. Fracture alignment and angular deformity was assessed using goniometric measurement functions on the PACS system (GE, Waukeshau, WI) obtained from preoperative and postoperative anteroposterior and lateral images for all subjects. Malalignment was defined as more than 5 degrees of angulation in any plane. Fourteen of the fractures were classified as OTA 42-A, 9 were OTA 43-A, and 4 were OTA 43-B. Analysis of post-closed reduction, preoperative anteroposterior radiographs revealed a mean of 7.9 degrees of coronal plane (range: 0.9 degrees-26 degrees) angulation. Post closed reduction preoperative lateral radiographs revealed a mean of 6.8 degrees sagittal plane (range: 0 degrees-24.6 degrees) angulation. Postoperative anteroposterior and lateral radiographs showed the distal segment returned to its anatomical alignment with a mean angulation of 0.5 degrees (range, 0 degrees-3.5 degrees) and 0.7 degrees (range, 0 degrees-4.2 degrees) of varus/ valgus and apex anterior/posterior angulation, respectively. These results showed an acceptable postopertative alignment in all 27 distal third fractures. No intra-operative or postoperative complications were noted in the study group. This

  16. Intramedullary nailing of clavicular midshaft fractures in adults using titanium elastic nail.

    Science.gov (United States)

    Chen, Qing-Yu; Kou, Dong-Quan; Cheng, Xiao-Jie; Zhang, Wei; Wang, Wei; Lin, Zhang-Qin; Cheng, Shao-Wen; Shen, Yue; Ying, Xiao-Zhou; Peng, Lei; Lv, Chuan-Zhu

    2011-01-01

    Studies showed elastic stable intramedullary nailing (ESIN) of displaced midclavicular fractures has excellent outcomes, as well as high complication rates and specific problems. The aim was to discuss ESIN of midshaft clavicular fractures. Totally 60 eligible patients (aged 18-63 years) were randomized to either ESIN group or non-operative group between January 2007 and May 2008. Clavicular shortening was measured after trauma and osseous consolidation. Radiographic union and complications were assessed. Function analysis including Constant shoulder scores and disabilities of the arm, shoulder and hand (DASH) scores were performed after a 15-month follow-up. ESIN led to a signifcantly shorter time to union, especially for simple fractures. In ESIN group, all patients got fracture union, of which 5 cases had medial skin irritation and 1 patient needed revision surgery because of implant failure. In the nonoperative group, there were 3 nonunion cases and 2 symptomatic malunions developed requiring corrective osteotomy. At 15 months after intramedullary stabilization, patients in the ESIN group were more satisfied with the appearance of the shoulder and overall outcome, and they benefited a lot from the great improvement of post-traumatic clavicular shortening. Furthermore, DASH scores were lower and Constant scores were significantly higher in contrast to the non-operative group. ESIN is a safe minimally invasive surgical technique with lower complication rate, faster return to daily activities, excellent cosmetic and better functional results, restoration of clavicular length for treating mid-shaft clavicular fractures, resulting in high overall satisfaction, which can be regard as an alternative to plate fixation or nonoperative treatment of mid-shaft clavicular fractures.

  17. Removal of a Broken Cannulated Intramedullary Nail: Review of the Literature and a Case Report of a New Technique

    Directory of Open Access Journals (Sweden)

    Amr A. Abdelgawad

    2013-01-01

    Full Text Available Nonunion of long bones fixed with nails may result in implant failure. Removal of a broken intramedullary nail may be a real challenge. Many methods have been described to allow for removal of the broken piece of the nail. In this paper, we are reviewing the different techniques to extract a broken nail, classifying them into different subsets, and describing a new technique that we used to remove a broken tibial nail with narrow canal. Eight different categories of implant removal methods were described, with different methods within each category. This classification is very comprehensive and was never described before. We described a new technique (hook captured in the medulla by flexible nail introduced from the locking hole which is a valuable technique in cases of nail of a small diameter where other methods cannot be used because of the narrow canal of the nail. Our eight categories for broken nail removal methods simplify the concepts of nail removal and allow the surgeon to better plan for the removal procedure.

  18. Minimally invasive treatment of trochanteric fractures with intramedullary nails. Technique and results.

    Science.gov (United States)

    Todor, Adrian; Pojar, Adina; Lucaciu, Dan

    2013-01-01

    The aim of the study was to evaluate the results of minimally invasive treatment of trochanteric fractures with the use of intramedullary nails. From September 2010 to September 2012 we treated 21 patients with pertrochanteric fractures by a minimally invasive technique using the Gamma 3 (Stryker, Howmedica) nail. There were 13 females and 8 men with a mean age of 74.1 years, ranging from 58 to 88 years. Fractures were classified as being stable (AO type 31-A1) in 5 cases and unstable (AO type 31-A2 and A3) in the rest of 16 cases. Patients were reviewed at 6 weeks and 3 months postoperatively. Mean surgery time was 46.8 minutes and mean hospital stay was 14.9 days. No patients required blood transfusions. During the hospital stay all the patients were mobilized with weight bearing as tolerated. All patients were available for review at 6 weeks, and 2 were lost to the 3 months follow up. 16 patients regained the previous level of activity. This minimally invasive technique using a gamma nail device for pertrochanteric fractures gives reliable good results with excellent preservation of hip function.

  19. The treatment of infected nonunion of the tibia following intramedullary nailing by the Ilizarov method.

    Science.gov (United States)

    Megas, Panagiotis; Saridis, Alkis; Kouzelis, Antonis; Kallivokas, Alkiviadis; Mylonas, Spyros; Tyllianakis, Minos

    2010-03-01

    The purpose of this study was to demonstrate the effectiveness of the Ilizarov method and circular external fixator in order to eradicate the infection and restore bone union, limb anatomy and functionality in cases with infected nonunion of the tibia following intramedullary nailing. During 7 years nine patients suffering from infected nonunion of the tibia after intramedullary nailing were treated in our department. The series comprised seven men and two women with an average age of 39.7 years (range 21-75 years). The patients had previously undergone an average of 4.8 operations (range 3-6 operations). Active purulent bone infection occurred in all nine patients. Bone defect was present in all patients with a mean size of 5 cm (range 2-12 cm). In three cases with bone defect less than 2 cm, monofocal compression osteosynthesis technique was used. In the rest cases where bone defect exceeded 2 cm, bifocal consecutive distraction-compression osteosynthesis technique was applied. Three patients required a local gastrocnemius flap. The mean follow-up period was 26.6 months (range 13-42 months). Results were evaluated using Paley's functional and radiological scoring system. Bone union was achieved in all nine patients without recurrence of infection during the follow-up period. Bone results were graded as excellent in five cases and good in the rest four cases. Functional results were graded as excellent in three cases, good in four and fare in two cases. Mean external fixation time was 187.4 days (range 89-412 days) and mean lengthening index was 32 days/cm (range 27-39 days/cm). Complications observed included eight grade II pin tract infections, axial deformity at the lengthening site in two cases and at the nonunion site in another two cases. Ankle joint stiffness was detected in five cases. The Ilizarov method may be an effective method in infected nonunions of the tibia following intramedullary nailing. Copyright 2009 Elsevier Ltd. All rights reserved.

  20. Computer-assisted three-dimensional correlation between the femoral neck-shaft angle and the optimal entry point for antegrade nailing.

    Science.gov (United States)

    Anastopoulos, George; Chissas, Dionisios; Dourountakis, Joseph; Ntagiopoulos, Panagiotis G; Magnisalis, Evaggelos; Asimakopoulos, Antonios; Xenakis, Theodore A

    2010-03-01

    Optimal entry point for antegrade femoral intramedullary nailing (IMN) remains controversial in the current medical literature. The definition of an ideal entry point for femoral IMN would implicate a tenseless introduction of the implant into the canal with anatomical alignment of the bone fragments. This study was undertaken in order to investigate possible existing relationships between the true 3D geometric parameters of the femur and the location of the optimum entry point. A sample population of 22 cadaveric femurs was used (mean age=51.09+/-14.82 years). Computed-tomography sections every 0.5mm for the entire length of femurs were produced. These sections were subsequently reconstructed to generate solid computer models of the external anatomy and medullary canal of each femur. Solid models of all femurs were subjected to a series of geometrical manipulations and computations using standard computer-aided-design tools. In the sagittal plane, the optimum entry point always lied a few millimeters behind the femoral neck axis (mean=3.5+/-1.5mm). In the coronal plane the optimum entry point lied at a location dependent on the femoral neck-shaft angle. Linear regression on the data showed that the optimal entry point is clearly correlated to the true 3D femoral neck-shaft angle (R(2)=0.7310) and the projected femoral neck-shaft angle (R(2)=0.6289). Anatomical parameters of the proximal femur, such as the varus-valgus angulation, are key factors in the determination of optimal entry point for nailing. The clinical relevance of the results is that in varus hips (neck-shaft angle shaft angle between 120 degrees and 130 degrees , the optimal entry point lies just medially to the trochanter tip (at the piriformis fossa) and the use of stiff implants is safe. In hips with neck-shaft angle over 130 degrees the anatomical axis of the canal is medially to the base of the neck, in a "restricted area". In these cases the entry point should be located at the insertion of the

  1. The effect of lower limb rehabilitation gymnastics on postoperative rehabilitation in elderly patients with femoral shaft fracture

    OpenAIRE

    Yang, Si-Dong; Ning, Sheng-Hua; Zhang, Li-Hong; Zhang, Ying-Ze; Ding, Wen-Yuan; Yang, Da-Long

    2016-01-01

    Abstract The purpose of this study was to explore the effect of lower limb rehabilitation gymnastics on postoperative rehabilitation in elderly patients with femoral shaft fracture after undergoing intramedullary nail fixation surgery. We collected medical records of elderly patients aged???60 years with femoral shaft fracture between 03/2010 and 03/2015 in Longyao County Hospital. Totally, 160 patients were identified and divided into the intervention group (n = 80) and the control group (n ...

  2. Evaluation of the Stryker S2 IM Nail Distal Targeting Device for reduction of radiation exposure: a case series study.

    Science.gov (United States)

    Anastopoulos, George; Ntagiopoulos, Panagiotis G; Chissas, Dionisios; Loupasis, George; Asimakopoulos, Antonios; Athanaselis, Eustratios; Megas, Panagiotis

    2008-10-01

    Distal locking is one challenging step during intramedullary nailing of femoral shaft fractures that can lead to an increase of radiation exposure. In the present study, the authors describe a technique for the distal locking of femoral nails, implementing a new targeting device in an attempt to reduce radiation exposure and operational time. Over a 2-year period, 127 consecutive cases of femoral shaft fractures were included in the study. All cases were treated with nailing of femoral shaft fractures with an unslotted reamed antegrade femoral nail and distal locking was performed with the use of a proximally mounted aiming device. Mean duration of the procedure was 63.5 18.1 min while the duration for distal locking was 6.6 +/- 2.6 min. In all successful cases, exposure from intraoperative fluoroscopy was 17.2 +/- 7.4 s for the whole operative procedure, and for distal locking was 2 shots, 1.35 s (range, 0.9-2.2 s) and 1.9 mGy (range, 1.1-2.9 mGy). Five cases (3.9%) were unsuccessful, but overall no intraoperative complications were encountered from the application of this technique. The ability of the device to correspond to the level of nail deformation and to properly identify the distal holes, reduced exposure to radiation compared to other published reports, and should be considered as a valuable tool for distal locking of femoral fractures.

  3. Atrophic femoral nonunion with bone loss: treatment with monorail transport: a case report.

    Science.gov (United States)

    Gay, David M; Voss, Frank R

    2004-08-01

    Nonunions are an uncommon outcome of femoral fractures. Atrophic nonunions with a leg length discrepancy secondary to bone loss are often the most difficult to treat, and the treatment options are limited. We present a case that uses concomitant monolateral external fixation and intramedullary nailing to heal a nonunion and perform a simultaneous 7-cm lengthening procedure in a 33-year-old female.

  4. Segmental transport after unreamed intramedullary nailing. Preliminary report of a "Monorail" system.

    Science.gov (United States)

    Raschke, M J; Mann, J W; Oedekoven, G; Claudi, B F

    1992-09-01

    The Ilizarov method of segmental bone transport has been shown to be an alternative to more conventional treatments of posttraumatic bony defects. After extensive clinical experience with the unreamed tibial nail in open fractures up to Grade IIIb, a new monorail fixation system for callus distraction and segmental bone transport was devised. This Monorail system is composed of an unreamed intramedullary (IM) nail and a unilateral AO distraction device. The new fixation method and the preliminary clinical experience are reported here. Four patients who previously sustained Grades II-IIIb open tibial fractures had an average bony defect of 9 cm. Two patients had previous bony infections. All patients had had serial debridements and myocutaneous flaps were required in three patients. An unreamed IM nail was inserted, and the transport device was applied. After an osteotomy, segmental transport was carried out until docking was achieved. The external fixator was removed after interlocking of the transported segment. The mean duration of external fixation was 17.9 days/cm and the mean period until roentgenographic consolidation of the distraction and nonunion site was 41.2 days/cm. There were two pin-tract infections but no IM infections. One nail broke after osseous consolidation of the regenerate at the distal interlocking site and required exchange. The goal of transport was achieved in all cases without angular or rotational deformity or length discrepancy. There were no neurovascular injuries.

  5. A STUDY OF UNSTABLE INTERTROCHANTERIC FEMORAL FRACTURES TREATED BY TROCHANTERIC FEMORAL NAIL

    Directory of Open Access Journals (Sweden)

    Sreenivasa Neikar

    2017-11-01

    Full Text Available BACKGROUND Intertrochanteric fracture is one of the most common fracture of the hip especially in the elderly. The incidence of intertrochanteric fracture is rising because of the increase in number of elderly population along with superadded osteoporosis. MATERIALS AND METHODS Study included cases of unstable intertrochanteric fractures (AO and OTA Classification 31-A2 and 31-A3 fracture patterns that were operated with the short trochanteric femoral nail, which fitted into the inclusion criteria done in medical college hospital, Vijayanagara Institute of Medical Sciences, Bellary, from February 2015 to September 2016. RESULTS The age distribution was from 40 to 80 years. The largest group of patients were from 61 to 70 years. The average age was 60.5 years. The number of male patients in our series was 20 (66.7% and female was 10 (33.3%. Right side was affected in 11 cases (36.7% and left side in 19 cases (63.3%. Good reduction was achieved in 23 patients (76.7%. Acceptable reduction was achieved in 7 (23.3% patients due to severe comminution. In our study, 25 patients (83.33% had no complications. We encountered one intraoperative complication in the form of greater trochanter splintering, while inserting the nail. In our study, we encountered following postoperative complications. We noticed one case of delayed union, one case of Z effect and 2 cases of varus malunion. CONCLUSION We conclude that short trochanteric femoral nail provides good fixation for unstable intertrochanteric fractures if proper preoperative planning, good reduction and surgical technique are followed leading to high rate of bone union and minimal soft tissue damage especially for Asian patients with relatively small femora.

  6. An in vivo evaluation of surface polishing of TAN intermedullary nails for ease of removal

    Directory of Open Access Journals (Sweden)

    JS Hayes

    2009-09-01

    Full Text Available Fractures of the tibia and femoral diaphysis are commonly repaired by intra-medullary (IM nailing. Currently IM nails are available in either electropolished stainless steel (SS or in Titanium-Aluminium-Niobium (TAN. After healing, removal of the nails still is common but removal of TAN IM nails often has complications whereas SS IM nails of the same design are less often associated with problems. We believe the differences in removal are due to the ability of TAN to promote strong bone on-growth. We have previously shown in vivo that polishing cortical screws reduces removal torque and the percentage of bone-implant contact. Therefore, we postulate that bony on-growth onto IM nails can be reduced by means of surface polishing, for ease of removal. Here we aim to compare the pull-out forces for removal of standard TAN (TAN-S compared to experimental paste polished TAN (TAN-PP IM nails from a bilateral non-fracture sheep tibia model after 12 months implantation. Histological analysis was also performed to assess tissue on-growth to the nails. We show that polishing significantly reduces (p=0.05 the extraction force required for TAN IM nail removal. This effect in part is attributable to the distinct tissue-material reaction produced. For TAN-S nails direct bone contact was observed while for TAN-PP nails a fibrous tissue interface was noted. Since TAN is preferred over SS for IM nailing due to superior biocompatibility and mechanical properties, we believe these findings could be used to recommend changes to current surface technologies of intramedullary nails to reduce complications seen with nail removal especially in rapidly growing bone in children.

  7. A patient specific finite element simulation of intramedullary nailing to predict the displacement of the distal locking hole.

    Science.gov (United States)

    Mortazavi, Javad; Farahmand, Farzam; Behzadipour, Saeed; Yeganeh, Ali; Aghighi, Mohammad

    2018-05-01

    Distal locking is a challenging subtask of intramedullary nailing fracture fixation due to the nail deformation that makes the proximally mounted targeting systems ineffective. A patient specific finite element model was developed, based on the QCT data of a cadaveric femur, to predict the position of the distal hole of the nail postoperatively. The mechanical interactions of femur and nail (of two sizes) during nail insertion was simulated using ABAQUS in two steps of dynamic pushing and static equilibrium, for the intact and distally fractured bone. Experiments were also performed on the same specimen to validate the simulation results. A good agreement was found between the model predictions and the experimental observations. There was a three-point contact pattern between the nail and medullary canal, only on the proximal fragment of the fractured bone. The nail deflection was much larger in the sagittal plane and increased for the larger diameter nail, as well as for more distally fractured or intact femur. The altered position of the distal hole was predicted by the model with an acceptable error (mean: 0.95; max: 1.5 mm, in different tests) to be used as the compensatory information for fine tuning of proximally mounted targeting systems. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Intramedullary nailing of clavicular midshaft fractures in adults using titanium elastic nail

    Directory of Open Access Journals (Sweden)

    CHEN Qing-yv

    2012-02-01

    Full Text Available 【Abstract】 Objective: Studies showed elastic stable intramedullary nailing (ESIN of displaced midclavicular fractures has excellent outcomes, as well as high complication rates and specific problems. The aim was to discuss ESIN of midshaft clavicular fractures. Methods: Totally 60 eligible patients (aged 18-63 years were randomized to either ESIN group or non-operative group between January 2007 and May 2008. Clavicular shortening was measured after trauma and osseous consolidation. Radiographic union and complications were assessed. Function analysis including Constant shoulder scores and disabilities of the arm, shoulder and hand (DASH scores were performed after a 15-month follow-up. Results: ESIN led to a signifcantly shorter time to union, especially for simple fractures. In ESIN group, all patients got fracture union, of which 5 cases had medial skin irritation and 1 patient needed revision surgery because of implant failure. In the nonoperative group, there were 3 nonunion cases and 2 symptomatic malunions developed requiring corrective osteotomy. At 15 months after intramedullary stabilization, patients in the ESIN group were more satisfied with the appearance of the shoulder and overall outcome, and they benefited a lot from the great improvement of post-traumatic clavicular shortening. Furthermore, DASH scores were lower and Constant scores were significantly higher in contrast to the non-operative group. Conclusion: ESIN is a safe minimally invasive surgical technique with lower complication rate, faster return to daily activities, excellent cosmetic and better functional results, restoration of clavicular length for treating mid-shaft clavicular fractures, resulting in high overall satisfaction, which can be regard as an alternative to plate fixation or nonoperative treatment of mid-shaft clavicular fractures. Key words: Clavicle; Fracture fixation intramedu- llary; Outcome assessment

  9. Heterotopic ossification of the elbow after closed reduction and retrograde intramedullary nailing for radial neck fracture treated by anconeus interposition.

    Science.gov (United States)

    Sreenivas, T; Menon, Jagdish; Nataraj, A R

    2013-12-01

    Heterotopic ossification around the elbow can lead to considerable functional disability. We describe a case of a 42-year-old man who developed heterotopic ossification of his elbow after closed reduction of the elbow dislocation and radial neck fracture and retrograde intramedullary nailing for radial neck fracture. During the follow-up after initial surgery, movements of the elbow were gradually deteriorated and diagnosed as heterotopic ossification of the elbow. Implant removal, radial head excision along with heterotopic mass, and also interposition of the anconeus muscle resulted in improvement of his elbow mobility. At 18 months of follow-up, patient had elbow flexion arc of 15°-110°, 70° of supination, and 50° of pronation without recurrence of heterotopic ossification. The uniqueness of this case lies in the treatment of heterotopic ossification of the elbow to prevent its recurrence, which was developed after retrograde intramedullary nailing for radial neck fracture following closed reduction.

  10. Ender’s Nail fixation in paediatric femoral shaft fractures.

    Directory of Open Access Journals (Sweden)

    Rajeev Dwivedi

    2013-12-01

    Flynn criteria 34 had excellent and 6 had satisfactory results. No poor results were seen. Conclusion: Ender’s nail fixation can be preferred method of treatment for femoral shaft fractures in age group 5 -15 years as the results are excellent and satisfactory. It is technically simple and can be done in a closed manner. It spares the vascularity and growth plate.

  11. Fracture Union in Closed Interlocking Nail in Femoral Fracture

    Directory of Open Access Journals (Sweden)

    R L Sahu

    2010-09-01

    Full Text Available INTRODUCTION: Fractures shaft femur is a major cause of morbidity and mortality in patients with lower extremity injuries. The objective of this study was to find out the outcome of Interlocking nail in fracture femur. METHODS: This study was conducted in the Department of Orthopaedic surgery in M. M. Medical College from July 2006 to November 2008. Seventy eight patients were recruited from Emergency and out patient department having closed fracture of femoral shaft. All patients were operated under general or spinal anesthesia. All patients were followed for nine months. RESULTS: Out of seventy eight patients, sixty nine patients underwent union in 90 to 150 days with a mean of 110.68 days. Touch down weight bearing was started on 2nd post-operative day. Complications found in four patients who had non-union, and five patients had delayed union which was treated with dynamization and bone graft. The results were excellent in 88.46% and good in 6.41% patients. CONCLUSIONS: We concluded that this technique is advantageous because of early mobilization (early weight bearing, less complication with good results and is economical. Keywords: close reamed interlocking nail, dynamization, femoral shaft fractures, union

  12. Gamma nail in the treatment of closed trochanteric fractures. Results and indications of 121 cases.

    Science.gov (United States)

    Kempf, I; Grosse, A; Taglang, G; Favreul, E

    2014-02-01

    The Gamma Nail is the latest advance in the treatment of trochanteric fractures based on intramedullary nailing principles during closed procedures. Its design is based on Küntscher's Y-nail and locking intramedullary (IM) nails. This paper reports the results from the first-ever series of 121 patients operated between 1988 and 1990. They were followed until bone union was achieved. The mean patient age was 75 years. Most patients were in poor general health and had unstable fractures. Anatomical preoperative reduction was achieved in 72% of cases. Fixation was good in 66% of cases and acceptable in 27% of cases. Intra-operative complications consisted of nine fractures without consequences. Of the treated patients, 83.4% resumed weight-bearing during the first week. There was one case of deep infection that resolved with treatment. The mortality rate was 12.3% at three months. We noted 7 alunions in varus, 3 in valgus, 2 in external rotation and 1 in internal rotation. There were no cases of non-union. In six cases, the screw had cut out of the femoral head. The drawbacks associated with surgical treatment methods for trochanteric fractures also apply to the Gamma nail. Nevertheless, one of its primary advantages is the possibility of using a closed procedure. When compared to Ender nailing, knee pain is absent and weight-bearing can be achieved in all patients, no matter the fracture type. Copyright © 2014. Published by Elsevier Masson SAS.

  13. Percutaneous clamping of spiral and oblique fractures of the tibial shaft: a safe and effective reduction aid during intramedullary nailing.

    Science.gov (United States)

    Collinge, Cory A; Beltran, Michael J; Dollahite, Henry A; Huber, Florian G

    2015-06-01

    The reduction of tibial shaft fractures during intramedullary nailing is important if limb alignment is to be restored and successful clinical outcomes are expected. We have used a percutaneously applied (or open) clamp or clamps to achieve and maintain reduction during nailing of all amendable tibial shaft fractures. In this article, we describe the technique and preliminary results comparing closed, simple spiral and oblique tibial shaft fractures (OTA 42-A1 and A2) managed with percutaneous clamp-assisted nailing (CAN) versus nailing using manual reduction (MRN) held by the surgical team. In the MRN group, there were an increased fracture gap (P = 0.04) and trends toward malalignment (P = 0.07) and healing time (P = 0.06) compared with the CAN group. There were also trends in clinical; no wound complications occurred in either group. We have found that percutaneous CAN of closed, simple spiral and oblique tibial shaft fractures seems safe and allows for early predictable union with reproducible alignment compared with nailing using MRN.

  14. Dual head screw hip nailing for trochanteric fractures

    Science.gov (United States)

    Mavrogenis, Andreas F.; Igoumenou, Vasilios G.; Megaloikonomos, Panayiotis D.; Panagopoulos, George N.; Galanopoulos, Ioannis P.; Vottis, Christos Th.; Karamanis, Eirinaios; Koulouvaris, Panayiotis; Papagelopoulos, Panayiotis J.

    2017-01-01

    Introduction: There are limited information and inconclusive results for dual head screw intramedullary hip nails for trochanteric fractures. Therefore, we performed a prospective study to evaluate the healing of fractures, and survival, function, and complications of patients operated with this implant. Methods: We prospectively studied 79 patients (61 women and 18 men; mean age: 84.7 years; range: 65–96 years) with a low-energy trochanteric fracture, treated with a dual head screw intramedullary hip nail from 2013 to 2016. The mean follow-up was 2.1 years (range: 1–3 years); seven patients were lost to follow up. This left 72 patients for further analysis. We evaluated the healing of fractures, and survival, function, and complications of patients. Results: Fracture healing was evident in 70 patients (97.2%) at 2–3 months postoperatively. One patient experienced cut-out and z-effect phenomenon of the head screws. Another patient experienced a periprosthetic femoral diaphysis fracture at the distal tip of the nail. A third patient experienced an acute postoperative superficial skin infection that was treated successfully with wound dressing changes and a course of antibiotics. Sixteen patients (22.2%) deceased within 12 months postoperatively. In the remaining patients, the Harris Hip Score (HHS) at 12 months postoperatively was excellent in 16 (28.6%), good in 23 (41.1%), fair in 10 (17.8%), and poor in 7 patients (12.5%). The function declined after the patients’ fracture. Fair and poor results were related to age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3 fracture types. Conclusion: The dual head screw intramedullary hip nail is associated with high healing and low complication rates for intertrochanteric fractures. The function of the patients is good or excellent in most cases; however, it declines, especially for those patients with age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3 fracture types

  15. Dual head screw hip nailing for trochanteric fractures

    Directory of Open Access Journals (Sweden)

    Mavrogenis Andreas F.

    2017-01-01

    Full Text Available Introduction: There are limited information and inconclusive results for dual head screw intramedullary hip nails for trochanteric fractures. Therefore, we performed a prospective study to evaluate the healing of fractures, and survival, function, and complications of patients operated with this implant. Methods: We prospectively studied 79 patients (61 women and 18 men; mean age: 84.7 years; range: 65–96 years with a low-energy trochanteric fracture, treated with a dual head screw intramedullary hip nail from 2013 to 2016. The mean follow-up was 2.1 years (range: 1–3 years; seven patients were lost to follow up. This left 72 patients for further analysis. We evaluated the healing of fractures, and survival, function, and complications of patients. Results: Fracture healing was evident in 70 patients (97.2% at 2–3 months postoperatively. One patient experienced cut-out and z-effect phenomenon of the head screws. Another patient experienced a periprosthetic femoral diaphysis fracture at the distal tip of the nail. A third patient experienced an acute postoperative superficial skin infection that was treated successfully with wound dressing changes and a course of antibiotics. Sixteen patients (22.2% deceased within 12 months postoperatively. In the remaining patients, the Harris Hip Score (HHS at 12 months postoperatively was excellent in 16 (28.6%, good in 23 (41.1%, fair in 10 (17.8%, and poor in 7 patients (12.5%. The function declined after the patients’ fracture. Fair and poor results were related to age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3 fracture types. Conclusion: The dual head screw intramedullary hip nail is associated with high healing and low complication rates for intertrochanteric fractures. The function of the patients is good or excellent in most cases; however, it declines, especially for those patients with age > 85 years, poor pre-fracture level of function, and AO/OTA-31-A3

  16. One-stage lengthening using a locked nailing technique for distal femoral shaft nonunions associated with shortening.

    Science.gov (United States)

    Wu, Chi-Chuan; Lee, Zhon-Liau

    2004-02-01

    To assess the effectiveness of a one-stage lengthening using a locked nail technique for the treatment of distal femoral shaft nonunions associated with shortening. Retrospective. University hospital. During a 6-year period, 36 distal femoral shaft nonunions associated with shortening (>1.5 cm) were treated by the one-stage lengthening technique. Indications for this technique were distal femoral shaft aseptic or quiescent infected nonunions, 1.5-5 cm shortening, and a fracture level suitable for the insertion of two distal locked screws. The surgical technique involved skeletal traction using the femoral condyle, local débridement, lengthening by lengthening was 2.5 cm (range 1.5-3.5 cm). One-stage lengthening using the locked nailing technique to treat distal femoral shaft nonunions associated with shortening can achieve a high success rate and low complication rate. The key to successful treatment is the patient's complete cooperation with strictly protected weight bearing until the fracture has healed.

  17. Flexible intramedullary nailing for unicameral cysts in children's long bones : Level of evidence: lV, case series.

    Science.gov (United States)

    Glanzmann, Michael C; Campos, Lautaro

    2007-07-01

    The purpose of this study was to evaluate the outcome of flexible intramedullary nailing for unicameral bone cysts in terms of function and osseous consolidation. Twenty-two unicameral bone cysts in children's long bones were treated by flexible intramedullary nailing. In 13 cases the bone cyst was diagnosed in a traumatic event leading to a pathologic fracture. Fifteen patients were referred to our clinic after failed conservative treatment. In 16 patients the cyst was located in the humerus, and in 6 patients in the femur. Mean duration of follow-up after surgery was 24 months. According to Capanna's criteria healing was obtained in 20 cases with a mean time of 16 months. Sixteen cysts healed completely. Four lesions were classified as grade 2, meaning that residual radiolucencies were radiographically visible at the latest follow-up. Two recurrences of humeral cysts were seen at 16 and 18 months postoperatively. The complication rate was minimal. Due to the immediate stabilization of the lesion aftercare becomes facile. This method allows prompt mobilization and early weight bearing without the necessity of a plaster cast. Further it prevents effectively the most common complication, a re-fracture or a pathologic fracture. Therefore we propose this surgical procedure as the treatment of choice for unicameral bone cysts in children's long bones.

  18. A novel smart navigation system for intramedullary nailing in orthopedic surgery.

    Directory of Open Access Journals (Sweden)

    Jaesuk Choi

    Full Text Available This paper proposes a novel smart surgical navigation system for intramedullary nailing in orthopedic surgery. Using a handle-integrated laser guidance module, the system can target a drill insertion point onto skin, indicating an accurate target position to perpendicularly access an invisible distal hole. The proposed handle-integration-based fixation of the laser guidance module precisely defines the relative position of the module with respect to the distal hole. Consequently, unlike conventional systems, the proposed system can indicate the target insertion point without any help from bulky and costly external position-tracking equipment that is usually required for compensating disturbances generated by external impacts. After insertion, a correct drilling direction toward the distal hole is guided by real-time drilling angle measurement modules-one integrated with the nail handle and the other with the drill body. Each module contains a 9-axis inertial sensor and a Bluetooth communication device. These two modules work together to provide real-time drilling angle data, allowing calculation of the directional error toward the center of the distal hole in real time. The proposed system removes the need for fluoroscopy and provides a compact and cost-effective solution compared with conventional systems.

  19. Outcomes of trochanteric femoral fractures treated with proximal femoral nail: an analysis of 100 consecutive cases

    Directory of Open Access Journals (Sweden)

    Korkmaz MF

    2014-04-01

    Full Text Available Mehmet Fatih Korkmaz,1 Mehmet Nuri Erdem,2 Zeliha Disli,3 Engin Burak Selcuk,4 Mustafa Karakaplan,1 Abdullah Gogus5 1Department of Orthopedics and Traumatology, Inonu University School of Medicine, Malatya, Turkey; 2Department of Orthopedics and Traumatology, Nisantasi University School of Medicine, Istanbul, Turkey; 3Department of Anesthesiology, Malatya Government Hospital, Malatya, Turkey; 4Department of Family Medicine, Inonu University School of Medicine, Malatya, Turkey; 5Department of Orthopedics and Traumatology, Florence Nightingale Hospital, Istanbul, Turkey Purpose: In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. Materials and methods: One hundred consecutive cases were included in the study. A case documentation form was used to obtain intraoperative data including age, sex, mechanism of injury, type of fracture according to Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF classification and the American Society of Anesthesiologists' (ASA physical status classification (ASA grade. Clinical and radiographic examinations were performed at the time of admission and at the 6th week; subsequent visits were organized on the 3rd month, 6th month, and 12th month, and in patients with longer follow-up and annually postoperatively. The Harris score of hip function was used, and any change in the position of the implants and the progress of the fracture union, which was determined radiologically, was noted. Results: The mean age of the patients was 77.66 years (range: 37–98 years, and the sex distribution was 32 males and 68 females. Seventy-three fractures were reduced by closed means, whereas 27 needed limited open reduction. The mean follow-up time for the study group was 31.3 months (range

  20. Elastic intramedullary nailing and DBM-Bone marrow injection for the treatment of simple bone cysts

    Science.gov (United States)

    Kanellopoulos, Anastasios D; Mavrogenis, Andreas F; Papagelopoulos, Panayiotis J; Soucacos, Panayotis N

    2007-01-01

    Background Simple or unicameral bone cysts are common benign fluid-filled lesions usually located at the long bones of children before skeletal maturity. Methods We performed demineralized bone matrix and iliac crest bone marrow injection combined with elastic intramedullary nailing for the treatment of simple bone cysts in long bones of 9 children with a mean age of 12.6 years (range, 4 to 15 years). Results Two of the 9 patients presented with a pathological fracture. Three patients had been referred after the failure of previous treatments. Four patients had large lesions with impending pathological fractures that interfered with daily living activities. We employed a ratio to ascertain the severity of the lesion. The extent of the lesion on the longitudinal axis was divided with the normal expected diameter of the long bone at the site of the lesion. The mean follow-up was 77 months (range, 5 to 8 years). All patients were pain free and had full range of motion of the adjacent joints at 6 weeks postoperatively. Review radiographs showed that all 7 cysts had consolidated completely (Neer stage I) and 2 cysts had consolidated partially (Neer stage II). Until the latest examination there was no evidence of fracture or re-fracture. Conclusion Elastic intramedullary nailing has the twofold benefits of continuous cyst decompression, and early immediate stability to the involved bone segment, which permits early mobilization and return to the normal activities of the pre-teen patients. PMID:17916249

  1. Elastic intramedullary nailing and DBM-Bone marrow injection for the treatment of simple bone cysts

    Directory of Open Access Journals (Sweden)

    Papagelopoulos Panayiotis J

    2007-10-01

    Full Text Available Abstract Background Simple or unicameral bone cysts are common benign fluid-filled lesions usually located at the long bones of children before skeletal maturity. Methods We performed demineralized bone matrix and iliac crest bone marrow injection combined with elastic intramedullary nailing for the treatment of simple bone cysts in long bones of 9 children with a mean age of 12.6 years (range, 4 to 15 years. Results Two of the 9 patients presented with a pathological fracture. Three patients had been referred after the failure of previous treatments. Four patients had large lesions with impending pathological fractures that interfered with daily living activities. We employed a ratio to ascertain the severity of the lesion. The extent of the lesion on the longitudinal axis was divided with the normal expected diameter of the long bone at the site of the lesion. The mean follow-up was 77 months (range, 5 to 8 years. All patients were pain free and had full range of motion of the adjacent joints at 6 weeks postoperatively. Review radiographs showed that all 7 cysts had consolidated completely (Neer stage I and 2 cysts had consolidated partially (Neer stage II. Until the latest examination there was no evidence of fracture or re-fracture. Conclusion Elastic intramedullary nailing has the twofold benefits of continuous cyst decompression, and early immediate stability to the involved bone segment, which permits early mobilization and return to the normal activities of the pre-teen patients.

  2. Comprehensive global evolution of intramedullary nailing of ...

    African Journals Online (AJOL)

    there has been great changes in design, materials and basic science ... proposed that the length of intramedullary implants be maximized to ... as intramedullary implant in 1917 (8). .... micro-movements and intermittent compression during.

  3. [Locked plating with minimally invasive percutaneous plate osteosynthesis versus intramedullary nailing of distal extra-articular tibial fracture: a retrospective study].

    Science.gov (United States)

    Yao, Qi; Ni, Jie; Peng, Li-bin; Yu, Da-xin; Yuan, Xiao-ming

    2013-12-17

    To compare the efficacies of minimally invasive plate osteosynthesis (MIPPO) and interlocking intramedullary nailing (IMN) in the treatment of extra-articular fractures of distal tibia. Retrospective reviews were conducted for 126 patients with extra-articular distal tibia fractures. Treatment was either MIPPO (n = 61) or IMN (n = 65). The outcomes were assessed by comparing operating duration, time to union, the last follow-up American Orthopedic Foot and Ankle Society (AOFAS) score and complication rate. The average follow-up period was 23.7 (12-53) months. In the minimally invasive plate osteosynthesis group, there were deep infections (n = 2), superficial infections (n = 5), delayed union (n = 2), malunion (n = 2) and knee joint pain (n = 10) were observed. In addition, the average operating duration (85.9 ± 18.9 min), average time to union (17.3 ± 3.8 weeks) and average AOFAS (83.2 ± 11.9) were analyzed. In the interlocking intramedullary nailing group, there were delayed union (n = 3), malunion (n = 12) and knee joint pain (n = 22). And the average operating duration (83.3 ± 15.7 min), average time to union (16.5 ± 3.1 weeks) and average AOFAS (84.9 ± 12.0) were analyzed. No statistical significance existed in operating duration, time to union and the last follow-up AOFAS between two groups (P > 0.05). However, the rates of malformation and knee joint pain were higher in the intramedullary nail group than those in the plate group. And the difference was statistically significant (P = 0.015, P = 0.025). Both MIPPO and IMN are effective for extra-articular fractures of distal tibia. However, the former has the advantage of lowers rate of malformation and knee joint pain. Therefore a surgeon should consider the degree of injury while managing extra-articular fracture of distal tibia.

  4. Use of intra-medullary stacked nailing in the reduction of proximal plastic deformity in a pediatric Monteggia fracture: a case report

    Directory of Open Access Journals (Sweden)

    Huntley James S

    2011-04-01

    Full Text Available Abstract Introduction In a Monteggia fracture dislocation, it is important to reduce the ulnar fracture completely. Extensive plastic deformation of the proximal ulna may make reduction by closed manipulation impossible. Case presentation We report the case of a four-year-old Caucasian boy in whom the plastic deformation of the proximal ulna was reduced, and this reduction was maintained, using intra-medullary stacked nailing. Conclusion The technique of stacked nailing is a useful addition to the armamentarium in the management of the potentially awkward Monteggia fracture.

  5. Study of treatment of short oblique and transverse fractures near isthmus of femur

    Directory of Open Access Journals (Sweden)

    Soumya Ghosh

    2014-01-01

    Full Text Available Background: Currently, the standard treatment for femoral shaft fractures in adults is intramedullary nailing. Objectives: Comparative assessment of results with open Kuntscher′s nailing (K-nailing and closed interlocking intramedullary nail in case of fracture shaft femur. Materials and Methods: This pilot project was conducted in a tertiary care hospital of a developing country on 40 patients in a time period of 1 year. A total of 20 patients were treated with intramedullary nailing in the tertiary care hospital while twenty received open fixation with K-nailing in a rural center. Results: There was no significant difference with regard to union rate, implant failure, infection, and fracture alignment between both groups. Conclusion: Open fixation with unlocked femoral nailing is technically less demanding and requires less operating time; additionally, there is no exposure to radiation and cost of the implant is cheaper. So, open K-nailing is still remains an option for the management of noncomminuted isthmus fractures of the femur in a developing country.

  6. Use of Titanium Elastic Nails in the Adult Diaphyseal Humerus Fractures

    Directory of Open Access Journals (Sweden)

    Upadhyay AS

    2017-07-01

    Full Text Available INTRODUCTION: Humerus shaft fractures in adults can be managed conservatively with functional braces or operatively with plate osteosynthesis or with intramedullary nailing. Conventionally humerus intramedullary nailing is done either using humerus interlocking nails or Enders nails. In this study we analyse the outcome of humerus shaft fractures (upper and middle third managed with closed ante- grade intramedullary titanium elastic nailing in terms of union rates, union time, functional results and complications. MATERIALS AND METHODS: A retrospective analysis of 25 patients treated with ante-grade intramedullary titanium elastic nailing was done during the period of August 2014 to June 2016 at our tertiary care centre. Skeletally mature patients with closed and acute fractures of the upper and middle shaft humerus of both sexes were included in the study. RESULTS: Twenty-five (100% fractures united with an average consolidation time of 14.98 weeks (10-32 weeks, and no fractures ended in non-union. Nail impingement was seen in two (8%, shoulder stiffness in one (4%. Functional results were excellent in 22 (88%, moderate in two (8% and poor in one (4%. There were 17 males and eight females with an average age of 39.08 years (range: 18-65 years. The average duration of hospital stay was 3.84±2.30 days. CONCLUSION: Closed ante-grade intramedullary titanium elastic nailing offers a safe and reliable method of fixing fractures of upper humeral shaft in adults. This method provides early fracture union, high union rates and less complications, in addition to early rehabilitation and reduces the hospital stay.

  7. Exposure of surgeons-in-training to radiation during intramedullary fixation of femoral shaft fractures

    International Nuclear Information System (INIS)

    Coetzee, J.C.; Van der Merwe, E.J.

    1992-01-01

    Owing to the continuous turnover of registrars and radiographers, most of the trauma-related orthopedic surgery in this academic hospital is done by inexperienced surgeons-in-training and the fluoroscopy by junior radiographers. This could result in excessive radiation doses. Calibrated lithium fluoride thermoluminescent chips were secured to various parts of the primary surgeon's body to quantify the radiation dose received during the insertion of an intramedullary nail. Closed intramedullary fixation of 15 fractures of the femur was done with interlocking as necessary. The total average exposure time was 14 minutes 45 seconds per procedure. Distal locking took up 31% of this time. The mean radiation dose to the surgeon's eyes and thyroid was 0,13 mGy and to the dominant hand 2,10 mGy. This would allow the performance of about 350 such procedures per year before the maximum permissible dose level was reached. Recommendations to decrease irradiation dosage are made. 6 refs., 6 tabs

  8. Femoral shaft fractures in children, treaties with elastic nails of titanium - TENs

    International Nuclear Information System (INIS)

    Solano Urrutia, Antonio Luis; Gallon, Luis Alfonso; Echandia, Carlos

    2003-01-01

    Femoral shaft fractures are a common and temporarily disabling injury in children. Recent advances in orthopedic traumatology have led us at the Hospital Universitario del Valle, in Cali, Colombia, to perform a case series observational study with the use of a more aggressive approach with the new endomedullar titanium nails (TENs) in children suffering femur shaft fractures, in a closed procedure performed under image intensification. The main purpose of this study was to evaluate the outcome of 30 children treated with these nails. Pediatric femoral shaft fractures are more common in males with approximately a 2.75:1 male to female ratio. The age distribution is bimodal, with peaks in the younger than 5 years and mid-teenage groups (10-14 years) because of the increased incidence of high-energy trauma in teenage children (mean age: 9 years). Overall, TENs allowed rapid mobilization with few complications. The results were excellent or satisfactory in our cases. No child lost rotational alignment in the postoperative period. Irritation of the soft tissue near the knee by the nail tip occurred in one patient. As indications, implantation technique, and aftercare are refined, TENs may prove to be the ideal implant to stabilize most pediatric femur shaft fractures, avoiding the prolonged immobilization and complications of traction and spica cast

  9. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    Science.gov (United States)

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  10. To evaluate the role of platelet-rich plasma in healing of acute diaphyseal fractures of the femur

    Directory of Open Access Journals (Sweden)

    Roop Singh

    2017-02-01

    Conclusion: PRP has no effect on femoral shaft fracture healing treated with closed intramedullary nailing. However, PRP and matrix scaffold provided by fibrin membrane may provide an artificial hematoma effect in the initial phase of healing in open or failed closed intramedullary nailing.

  11. Use of the suprapatellar approach in intramedullary nailing of a multi-fragmentary dislocated tibia fracture with a hypermobile intermediate fragment in a young patient

    Directory of Open Access Journals (Sweden)

    Patrick Haubruck

    2017-01-01

    Full Text Available A case of an adolescent female patient who suffered from first grade open multi-fragment fracture of the tibia (AO42-C2 with a large hypermobile intermediate fragment is presented in this case report. Intramedullary nailing of the tibia remains the treatment of choice despite a high risk of malformation and anterior knee pain especially in multi-fragment fractures. Here the suprapatellar approach as a semiextended nailing technique seems favorable. The specialty in our case was an early change of procedures necessary due to persistent swelling during external fixation based on the hypermobile intermediate fragment. Decision in favor of this surgical technique was conducted in order to achieve beneficial alignment and union while protecting the softtissue despite the hypermobile intermediate fragment and decrease the risk of anterior knee pain. In our case we achieved successful alignment and proper bone healing without any signs of anterior knee pain or limitations in the range of motion of the knee. With this report we would like to recommend the suprapatellar approach as a favorable alternative in intramedullary nailing in this type of fracture also in young patients.

  12. Is Contralateral Templating Reliable for Establishing Rotational Alignment During Intramedullary Stabilization of Femoral Shaft Fractures? A Study of Individual Bilateral Differences in Femoral Version.

    Science.gov (United States)

    Croom, William P; Lorenzana, Daniel J; Auran, Richard L; Cavallero, Matthew J; Heckmann, Nathanael; Lee, Jackson; White, Eric A

    2018-02-01

    To determine native individual bilateral differences (IBDs) in femoral version in a diverse population. Computed tomography scans with complete imaging of uninjured bilateral femora were used to determine femoral version and IBDs in version. Age, sex, and ethnicity of each subject were also collected. Femoral version and IBDs in version were correlated with demographic variables using univariate and multivariate regression models. One hundred sixty-four subjects were included in the study. The average femoral version was 9.4 degrees (±9.4 degrees). The mean IBD in femoral version was 5.4 degrees (±4.4 degrees, P alignment during intramedullary stabilization of diaphyseal femur fractures. This is also an important consideration when considering malrotation of femur fractures because most studies define malrotation as a greater than 10-15-degree difference compared with the contralateral side. Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  13. Rotational Mal-Alignment after Reamed Intramedullary Nailing for tibial shaft fracture.

    Science.gov (United States)

    Khan, Sher Baz; Mohib, Yasir; Rashid, Rizwan Haroon; Rashid, Haroonur

    2016-10-01

    Intra-medullary (IM) nailing is standard of care for unstable tibial shaft fractures. Malrotation is very common but it is under-recognised, inpart because of variation in normal anatomy and partly due to difficulty in accurately assessing rotation. This study was planned to evaluate the frequency of rotational mal-alignment after reamed tibia IMnailing. This cross-sectional study was conducted at Aga khan University Hospital, Karachi, and comprised patients with tibia shaft fractures managed with IMnailing from January to December 2014. All the patients were assessed intra-operatively for rotational alignment using the knee and ankle fluoroscopic images. There were 81 patients with a mean age of 38±16.9 years. There were 64(79%) male patients. Overall the incidence of malrotation was in 20(24.7%) cases. Rotational mal-alignment is one of the preventable complications after IMnailing which can be assesed intra-operatively under fluoroscope.

  14. Localized cortical thickening of the femoral diaphysis captured on an X-ray before alendronate therapy in two cases of atypical femoral fracture

    Energy Technology Data Exchange (ETDEWEB)

    Iizuka, Yoichi [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Shibukawa General Hospital, Department of Orthopedic Surgery, Shibukawa, Gunma (Japan); Takechi, Rumi [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Gunma Cardiovascular Center, Department of Orthopaedic Surgery, Maebashi, Gunma (Japan); Iizuka, Haku; Takagishi, Kenji [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Omodaka, Takuya [Gunma University Graduate School of Medicine, Department of Orthopedic Surgery, Maebashi, Gunma (Japan); Gunma Central Hospital, Department of Orthopedic Surgery, Maebashi, Gunma (Japan)

    2016-10-15

    We herein report two cases of atypical femoral fracture (AFF). X-ray examinations at the first visit of these two female patients showed a complete fracture of the femoral diaphysis diagnosed as an atypical femoral fracture (AFF). X-rays of these two cases also showed localized cortical thickening of the femoral diaphysis. Both patients had been taking alendronate for more than 3 years because of postmenopausal osteoporosis. We assumed that both of the fractures were associated with the long-term use of alendronate. However, we retrospectively identified localized cortical thickening of the femoral diaphysis on an X-ray taken before the alendronate therapy in both of these cases. Therefore, we suspected a pathogenesis of AFFs in which preexisting stress or an insufficient fracture unrelated to bisphosphonate (BP) therapy and subsequent suppression of bone turnover due to BP administration led to the occurrence of an AFF. The patient underwent surgery using intramedullary nails in both of these cases, followed by the administration of teriparatide, and they were able to walk without any support at the final follow-up examination. (orig.)

  15. Management of long bone fractures using SIGN nail: experience ...

    African Journals Online (AJOL)

    Background: Intramedullary nailing with interlocking nails has become the treatment of choice for closed diaphyseal fractures of femur and tibia. When possible locked nailing should be performed as a closed procedure. Fractures fixed by interlocking nailing have comparatively less complications in fracture healing.

  16. Outcome analysis of retrograde nailing and less invasive stabilization system in distal femoral fractures: A retrospective analysis

    Directory of Open Access Journals (Sweden)

    Christian Hierholzer

    2011-01-01

    Full Text Available Background: Two major therapeutic principles can be employed for the treatment of distal femoral fractures: retrograde intramedullary (IM nailing (RN or less invasive stabilization on system (LISS. Both operative stabilizing systems follow the principle of biological osteosynthesis. IM nailing protects the soft-tissue envelope due to its minimally invasive approach and closed reduction techniques better than distal femoral locked plating. The purpose of this study was to evaluate and compare outcome of distal femur fracture stabilization using RN or LISS techniques. Materials and Methods: In a retrospective study from 2003 to 2008, we analyzed 115 patients with distal femur fracture who had been treated by retrograde IM nailing (59 patients or LISS plating (56 patients. In the two cohort groups, mean age was 54 years (17-89 years. Mechanism of injury was high energy impact in 57% (53% RN, 67% LISS and low-energy injury in 43% (47% RN, 33% LISS, respectively. Fractures were classified according to AO classification: there were 52 type A fractures (RN 31, LISS 21 and 63 type C fractures (RN 28, LISS 35; 32% (RN and 56% (LISS were open and 68% (RN and 44% (LISS were closed fractures, respectively. Functional and radiological outcome was assessed. Results: Clinical and radiographic evaluation demonstrated osseous healing within 6 months following RN and following LISS plating in over 90% of patients. However, no statistically significant differences were found for the parameters time to osseous healing, rate of nonunion, and postoperative complications. The following complications were treated: hematoma formation (one patient RN and three patients LISS, superficial infection (one patient RN and three patients LISS, deep infection (2 patients LISS. Additional secondary bone grafting for successful healing 3 months after the primary operation was required in four patients in the RN (7% of patients and six in the LISS group (10% of patients

  17. Functional Outcome After Antegrade Femoral Nailing : A Comparison of Trochanteric Fossa Versus Tip of Greater Trochanter Entry Point

    NARCIS (Netherlands)

    Moein, Chloe Ansari; ten Duis, Henk-Jan; Oey, Liam; de Kort, Gerard; van der Meulen, Wout; Vermeulen, Karin; van der Werken, Christiaan

    Objectives: This study was performed to explore the relationship between entry point-related soft tissue damage in antegrade femoral nailing and the functional outcome in patients with a proximal third femoral shaft fracture. Design: Retrospective clinical trial. Setting: Level I university trauma

  18. Reamed intramedullary exchange nailing in the operative treatment of aseptic tibial shaft nonunion.

    Science.gov (United States)

    Hierholzer, Christian; Friederichs, Jan; Glowalla, Claudio; Woltmann, Alexander; Bühren, Volker; von Rüden, Christian

    2017-08-01

    The aim of this study was to evaluate a standardized treatment protocol regarding the rate of secondary bone union, complications, and functional outcome. This study was started as a prospective study in a single Level I Trauma Centre between 2003 and 2012. The study group consisted of 188 patients with the diagnosis of an aseptic tibial shaft nonunion. Exchange nailing was performed following a standardized surgical protocol. Long-term follow-up was analyzed for rate of bone healing and functional outcome. Osseous healing was achieved in 182 out of 188 patients (97 %). In 165 out of 188 patients (88 %), bone healing was observed timely and uneventfully after a single exchange nailing procedure. An open approach was necessary in 32 patients (17 %). Twenty-three patients (12 %) required additional therapy such as extracorporeal shock wave therapy. Post-operative complications were observed in seven patients (4 %). Almost all patients demonstrated osseous healing within 12 months, with the majority of osseous healing occurring within six months. A relevant shortening of the fractured tibia was observed in 20 out of 188 patients (11 %). After a median follow-up of 23 months (range 12-45 months), outcome was evaluated using the assessment system of Friedman/Wyman. In summary, 154 out of 188 patients (82 %) had a good functional long-term result. Reamed intramedullary exchange nailing including correction of axis alignment is a safe and effective treatment of aseptic tibial shaft nonunion with a high rate of bone healing and a good radiological and functional long-term outcome.

  19. Early effect of Ti-24Nb-4Zr-7.9Sn intramedullary nails on fractured bone

    International Nuclear Information System (INIS)

    Guo, Z.; Fu, J.; Zhang, Y.Q.; Hu, Y.Y.; Wu, Z.G.; Shi, L.; Sha, M.; Li, S.J.; Hao, Y.L.; Yang, R.

    2009-01-01

    A multifunctional titanium Ti-24Nb-4Zr-7.9Sn alloy (abbreviated as Ti2448) with ultra-low elastic modulus and high strength has been developed recently for potential biomedical applications. In this study, the bone healing and stability of implants in a rabbit tibial fracture model were investigated using intramedullary nails made of both the Ti2448 and Ti-6Al-4V ELI alloys. X-ray radiographic analysis showed that the volume fractions of new calluses formed around the fractured tibia increased with implantation times up to 4 weeks in both groups but no obvious difference was found between the alloys at the same time point. The micro-CT analysis revealed that, in the distal end of the tibia, there were many new calluses around nails made of the Ti2448 alloy that were confirmed by histological observations. The above analysis was consistent with tensile testing results performed 4 weeks after implantation. The mean maximum tensile force to failure of the newly formed calluses was similar between both groups whereas the mean maximum pull-out forces of the implanted nails were larger in the group of the Ti2448 alloy. Four weeks after fixation, no obvious difference in the degree of fracture healing was found between both groups. These results suggested that, in the early stage of fixation, the nails with ultra-low elastic modulus improved the new bone formation in the marrow cavity.

  20. Outcomes of trochanteric femoral fractures treated with proximal femoral nail: an analysis of 100 consecutive cases.

    Science.gov (United States)

    Korkmaz, Mehmet Fatih; Erdem, Mehmet Nuri; Disli, Zeliha; Selcuk, Engin Burak; Karakaplan, Mustafa; Gogus, Abdullah

    2014-01-01

    In this study, we aimed to report the results of a retrospective study carried out at our institute regarding cases of patients who had suffered proximal femoral fractures between January 2002 and February 2007, and who were treated with a proximal femoral nail. One hundred consecutive cases were included in the study. A case documentation form was used to obtain intraoperative data including age, sex, mechanism of injury, type of fracture according to Association for Osteosynthesis/Association for the Study of Internal Fixation (AO/ASIF) classification and the American Society of Anesthesiologists' (ASA) physical status classification (ASA grade). Clinical and radiographic examinations were performed at the time of admission and at the 6th week; subsequent visits were organized on the 3rd month, 6th month, and 12th month, and in patients with longer follow-up and annually postoperatively. The Harris score of hip function was used, and any change in the position of the implants and the progress of the fracture union, which was determined radiologically, was noted. The mean age of the patients was 77.66 years (range: 37-98 years), and the sex distribution was 32 males and 68 females. Seventy-three fractures were reduced by closed means, whereas 27 needed limited open reduction. The mean follow-up time for the study group was 31.3 months (range: 12-75 months). Postoperative radiographs showed a near-anatomical fracture reduction in 78% of patients. The Harris hip score was negatively correlated with the ASA score and patient age. No cases of implant failure were observed. Three patients died before discharge (one due to pulmonary embolism, two due to cardiac arrest), and five patients died due to unrelated medical conditions within the first 3 months of the follow-up. Our study showed that proximal femoral nail is a reliable fixation with good fracture union, and it is not associated with major complications in any type of trochanteric femoral fracture.

  1. [Treatment of periprosthetic femoral fractures after total hip arthroplasty with specially constructed retrograde hollow nails].

    Science.gov (United States)

    Szalay, G; Meyer, C; Mika, J; Schnettler, R; Thormann, U

    2014-12-01

    Treatment of periprosthetic fractures by implantation of a specially constructed, retrograde hollow nail which fits over the tip of the prosthesis and becomes locked on it. Periprosthetic femoral fractures with firmly anchored prosthesis shaft after total hip arthroplasty of types B1 and C according to the Vancouver classification. Loosened prosthesis (type B2/B3) and trochanteric fractures (type A). Broken or damaged prosthesis, florid inflammation and soft tissue injuries in the operation field, contracted knee joint, advanced deformation in the knee joint and distal femur, enclosed prosthesis and general contraindications. In a supine position the periprosthetic fracture is exposed via a lateral access. For cemented prostheses the cement is removed around the tip of the prosthesis (at least 2-3 cm) and medullary cavity. Arthrotomy with flexion of the knee joint and marking of the nail entry point. Drill the medullary cavity, retrograde introduction of the nail, visually fit the nail over the tip of the prosthesis and lock the nail with the prosthesis. If necessary use additional spongiosaplasty or also placement of additional cerclages depending on fracture type and size of the defect zone. Lock the nail distally. Use intraoperative radiological imaging to control correct positioning and length of the nail. Close the wound layer by layer with placement of suction drainage devices and dressing. Partial loading for 6 weeks with a subsequent pain-adapted loading gradient until full loading is possible. If selective partial loading is not possible, a decision must be made in individual cases as to whether the intraoperative findings allow immediate full loading. From 2004 to 2011 a total of 25 periprosthetic femoral fractures in 25 patients were treated in 2 locations using specially constructed slotted hollow nails. Within the framework of a retrospective study 20 of these patients (16 female and 4 male; average age 77.2 [72-84] years) were clinically and

  2. Dose-Effect Relationships for Femoral Fractures After Multimodality Limb-Sparing Therapy of Soft-Tissue Sarcomas of the Proximal Lower Extremity

    Energy Technology Data Exchange (ETDEWEB)

    Pak, Daniel; Vineberg, Karen A. [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Griffith, Kent A. [Biostatistics Unit, Comprehensive Cancer Center, University of Michigan, Ann Arbor, MI (United States); Sabolch, Aaron [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Chugh, Rashmi [Department of Internal Medicine, Division of Hematology/Oncology, University of Michigan, Ann Arbor, MI (United States); Ben-Josef, Edgar [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States); Biermann, Janet Sybil [Department of Orthopedic Surgery, University of Michigan, Ann Arbor, MI (United States); Feng, Mary, E-mail: maryfeng@umich.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, MI (United States)

    2012-07-15

    Purpose: We investigated the clinical and dosimetric predictors for radiation-associated femoral fractures in patients with proximal lower extremity soft tissue sarcomas (STS). Methods and Materials: We examined 131 patients with proximal lower extremity STS who received limb-sparing surgery and external-beam radiation therapy between 1985 and 2006. Five (4%) patients sustained pathologic femoral fractures. Dosimetric analysis was limited to 4 fracture patients with full three-dimensional dose information, who were compared with 59 nonfracture patients. The mean doses and volumes of bone (V{sub d}) receiving specified doses ({>=}30 Gy, 45 Gy, 60 Gy) at the femoral body, femoral neck, intertrochanteric region, and subtrochanteric region were compared. Clinical predictive factors were also evaluated. Results: Of 4 fracture patients in our dosimetric series, there were three femoral neck fractures with a mean dose of 57.6 {+-} 8.9 Gy, V30 of 14.5 {+-} 2.3 cc, V45 of 11.8 {+-} 1.1 cc, and V60 of 7.2 {+-} 2.2 cc at the femoral neck compared with 22.9 {+-} 20.8 Gy, 4.8 {+-} 5.6 cc, 2.5 {+-} 3.9 cc, and 0.8 {+-} 2.7 cc, respectively, for nonfracture patients (p < 0.03 for all). The femoral neck fracture rate was higher than at the subtrochanteric region despite lower mean doses at these subregions. All fracture sites received mean doses greater than 40 Gy. Also, with our policy of prophylactic femoral intramedullary nailing for high-risk patients, there was no significant difference in fracture rates between patients with and without periosteal excision. There were no significant differences in age, sex, tumor size, timing of radiation therapy, and use of chemotherapy between fracture and nonfracture patients. Conclusions: These dose-volume toxicity relationships provide RT optimization goals to guide future efforts for reducing pathologic fracture rates. Prophylactic femoral intramedullary nailing may also reduce fracture risk for susceptible patients.

  3. Dose–Effect Relationships for Femoral Fractures After Multimodality Limb-Sparing Therapy of Soft-Tissue Sarcomas of the Proximal Lower Extremity

    International Nuclear Information System (INIS)

    Pak, Daniel; Vineberg, Karen A.; Griffith, Kent A.; Sabolch, Aaron; Chugh, Rashmi; Ben-Josef, Edgar; Biermann, Janet Sybil; Feng, Mary

    2012-01-01

    Purpose: We investigated the clinical and dosimetric predictors for radiation-associated femoral fractures in patients with proximal lower extremity soft tissue sarcomas (STS). Methods and Materials: We examined 131 patients with proximal lower extremity STS who received limb-sparing surgery and external-beam radiation therapy between 1985 and 2006. Five (4%) patients sustained pathologic femoral fractures. Dosimetric analysis was limited to 4 fracture patients with full three-dimensional dose information, who were compared with 59 nonfracture patients. The mean doses and volumes of bone (V d ) receiving specified doses (≥30 Gy, 45 Gy, 60 Gy) at the femoral body, femoral neck, intertrochanteric region, and subtrochanteric region were compared. Clinical predictive factors were also evaluated. Results: Of 4 fracture patients in our dosimetric series, there were three femoral neck fractures with a mean dose of 57.6 ± 8.9 Gy, V30 of 14.5 ± 2.3 cc, V45 of 11.8 ± 1.1 cc, and V60 of 7.2 ± 2.2 cc at the femoral neck compared with 22.9 ± 20.8 Gy, 4.8 ± 5.6 cc, 2.5 ± 3.9 cc, and 0.8 ± 2.7 cc, respectively, for nonfracture patients (p < 0.03 for all). The femoral neck fracture rate was higher than at the subtrochanteric region despite lower mean doses at these subregions. All fracture sites received mean doses greater than 40 Gy. Also, with our policy of prophylactic femoral intramedullary nailing for high-risk patients, there was no significant difference in fracture rates between patients with and without periosteal excision. There were no significant differences in age, sex, tumor size, timing of radiation therapy, and use of chemotherapy between fracture and nonfracture patients. Conclusions: These dose–volume toxicity relationships provide RT optimization goals to guide future efforts for reducing pathologic fracture rates. Prophylactic femoral intramedullary nailing may also reduce fracture risk for susceptible patients.

  4. A comparative study of intramedullary interlocking nailing and minimally invasive plate osteosynthesis in extra articular distal tibial fractures.

    Science.gov (United States)

    Daolagupu, Arup K; Mudgal, Ashwani; Agarwala, Vikash; Dutta, Kaushik K

    2017-01-01

    Extraarticular distal tibial fractures are among the most challenging fractures encountered by an orthopedician for treatment because of its subcutaneous location, poor blood supply and decreased muscular cover anteriorly, complications such as delayed union, nonunion, wound infection, and wound dehiscence are often seen as a great challenge to the surgeon. Minimally invasive plate osteosynthesis (MIPO) and intramedullary interlocking nail (IMLN) are two well-accepted and effective methods, but each has been historically related to complications. This study compares clinical and radiological outcome in extraarticular distal tibia fractures treated by intramedullary interlocking nail (IMLN) and minimally invasive plate osteosynthesis (MIPO). 42 patients included in this study, 21 underwent IMLN and 21 were treated with MIPO who met the inclusion criteria and operated between June 2014 and May 2015. Patients were followed up for clinical and radiological evaluation. In IMLN group, average union time was 18.26 weeks compared to 21.70 weeks in plating group which was significant ( P ankle stiffness, and infection, were seen in interlocking group as compared to plating group. Average functional outcome according to American Orthopedic Foot and Ankle Society score was measured which came out to be 96.67. IMLN group was associated with lesser duration of surgery, earlier weight bearing and union rate, lesser incidence of infection and implant irritation which makes it a preferable choice for fixation of extra-articular distal tibial fractures. However, larger randomized controlled trials are required for confirming the results.

  5. A Prospective Study to Evaluate the Management of Sub-trochanteric Femur Fractures with Long Proximal Femoral Nail.

    Science.gov (United States)

    Kumar, M; Akshat, V; Kanwariya, A; Gandhi, M

    2017-11-01

    Introduction: Sub-trochanteric fractures of the femur remains one of the most challenging fractures faced by orthopaedic surgeons. This study was done to analyse the management and complications of sub-trochanteric fractures using long proximal femoral nail (PFN). Materials and Methods: This was a prospective study of 50 patients with sub-trochanteric fractures of femur who were treated with long PFN at a tertiary care center from July 2012 to June 2016. The fractures were classified according to Seinsheimer classification. All patients were assessed functionally by Harris Hip Score. Results: Average duration of union was 17.08 weeks (range 13 to 32 weeks), union was achieved in 92% cases. Closed reduction was achieved in 68% cases and open reduction was required in 32% cases. Various intraoperative complications were seen in 12% and delayed complications in 26% of cases. Good anatomical results were achieved in 86% of cases and 14% were fair. As per Harris Hip score, excellent results were noted in 28% cases, good in 56% cases and fair in 16% cases. Conclusion: The long PFN is a reliable implant for subtrochanteric femur fractures, with high rate of bone union and minimal soft tissue damage. Intramedullary fixation has biological and biomechanical advantages, but the surgery is technically demanding.

  6. A Prospective Study to Evaluate the Management of Sub-trochanteric Femur Fractures with Long Proximal Femoral Nail

    Directory of Open Access Journals (Sweden)

    Kumar M

    2017-11-01

    Full Text Available INTRODUCTION: Sub-trochanteric fractures of the femur remains one of the most challenging fractures faced by orthopaedic surgeons. This study was done to analyse the management and complications of sub-trochanteric fractures using long proximal femoral nail (PFN. MATERIALS AND METHODS: This was a prospective study of 50 patients with sub-trochanteric fractures of femur who were treated with long PFN at a tertiary care center from July 2012 to June 2016. The fractures were classified according to Seinsheimer classification. All patients were assessed functionally by Harris Hip Score. RESULTS: Average duration of union was 17.08 weeks (range 13 to 32 weeks, union was achieved in 92% cases. Closed reduction was achieved in 68% cases and open reduction was required in 32% cases. Various intraoperative complications were seen in 12% and delayed complications in 26% of cases. Good anatomical results were achieved in 86% of cases and 14% were fair. As per Harris Hip score, excellent results were noted in 28% cases, good in 56% cases and fair in 16% cases. CONCLUSION: The long PFN is a reliable implant for sub-trochanteric femur fractures, with high rate of bone union and minimal soft tissue damage. Intramedullary fixation has biological and biomechanical advantages, but the surgery is technically demanding.

  7. Robust identification and localization of intramedullary nail holes for distal locking using CBCT: a simulation study.

    Science.gov (United States)

    Kamarianakis, Z; Buliev, I; Pallikarakis, N

    2011-05-01

    Closed intramedullary nailing is a common technique for treatment of femur and tibia fractures. The most challenging step in this procedure is the precise placement of the lateral screws that stabilize the fragmented bone. The present work concerns the development and the evaluation of a method to accurately identify in the 3D space the axes of the nail hole canals. A limited number of projection images are acquired around the leg with the help of a C-arm. On two of them, the locking hole entries are interactively selected and a rough localization of the hole axes is performed. Perpendicularly to one of them, cone-beam computed tomography (CBCT) reconstructions are produced. The accurate identification and localization of the hole axes are done by an identification of the centers of the nail holes on the tomograms and a further 3D linear regression through principal component analysis (PCA). Various feature-based approaches (RANSAC, least-square fitting, Hough transform) have been compared for best matching the contours and the centers of the holes on the tomograms. The robustness of the suggested method was investigated using simulations. Programming is done in Matlab and C++. Results obtained on synthetic data confirm very good localization accuracy - mean translational error of 0.14 mm (std=0.08 mm) and mean angular error of 0.84° (std=0.35°) at no radiation excess. Successful localization can be further used to guide a surgeon or a robot for correct drilling the bone along the nail openings. Copyright © 2010 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Dose--effect relationships for femoral fractures after multimodality limb-sparing therapy of soft-tissue sarcomas of the proximal lower extremity.

    Science.gov (United States)

    Pak, Daniel; Vineberg, Karen A; Griffith, Kent A; Sabolch, Aaron; Chugh, Rashmi; Ben-Josef, Edgar; Biermann, Janet Sybil; Feng, Mary

    2012-07-15

    We investigated the clinical and dosimetric predictors for radiation-associated femoral fractures in patients with proximal lower extremity soft tissue sarcomas (STS). We examined 131 patients with proximal lower extremity STS who received limb-sparing surgery and external-beam radiation therapy between 1985 and 2006. Five (4%) patients sustained pathologic femoral fractures. Dosimetric analysis was limited to 4 fracture patients with full three-dimensional dose information, who were compared with 59 nonfracture patients. The mean doses and volumes of bone (V(d)) receiving specified doses (≥30 Gy, 45 Gy, 60 Gy) at the femoral body, femoral neck, intertrochanteric region, and subtrochanteric region were compared. Clinical predictive factors were also evaluated. Of 4 fracture patients in our dosimetric series, there were three femoral neck fractures with a mean dose of 57.6 ± 8.9 Gy, V30 of 14.5 ± 2.3 cc, V45 of 11.8 ± 1.1 cc, and V60 of 7.2 ± 2.2 cc at the femoral neck compared with 22.9 ± 20.8 Gy, 4.8 ± 5.6 cc, 2.5 ± 3.9 cc, and 0.8 ± 2.7 cc, respectively, for nonfracture patients (p fracture rate was higher than at the subtrochanteric region despite lower mean doses at these subregions. All fracture sites received mean doses greater than 40 Gy. Also, with our policy of prophylactic femoral intramedullary nailing for high-risk patients, there was no significant difference in fracture rates between patients with and without periosteal excision. There were no significant differences in age, sex, tumor size, timing of radiation therapy, and use of chemotherapy between fracture and nonfracture patients. These dose-volume toxicity relationships provide RT optimization goals to guide future efforts for reducing pathologic fracture rates. Prophylactic femoral intramedullary nailing may also reduce fracture risk for susceptible patients. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Trochanteric fracture-implant motion during healing - A radiostereometry (RSA) study.

    Science.gov (United States)

    Bojan, Alicja J; Jönsson, Anders; Granhed, Hans; Ekholm, Carl; Kärrholm, Johan

    2018-03-01

    Cut-out complication remains a major unsolved problem in the treatment of trochanteric hip fractures. A better understanding of the three-dimensional fracture-implant motions is needed to enable further development of clinical strategies and countermeasures. The aim of this clinical study was to characterise and quantify three-dimensional motions between the implant and the bone and between the lag screw and nail of the Gamma nail. Radiostereometry Analysis (RSA) analysis was applied in 20 patients with trochanteric hip fractures treated with an intramedullary nail. The following three-dimensional motions were measured postoperatively, at 1 week, 3, 6 and 12 months: translations of the tip of the lag screw in the femoral head, motions of the lag screw in the nail, femoral head motions relative to the nail and nail movements in the femoral shaft. Cranial migration of the tip of the lag screw dominated over the other two translation components in the femoral head. In all fractures the lag screw slid laterally in the nail and the femoral head moved both laterally and inferiorly towards the nail. All femoral heads translated posteriorly relative to the nail, and rotations occurred in both directions with median values close to zero. The nail tended to retrovert in the femoral shaft. Adverse fracture-implant motions were detected in stable trochanteric hip fractures treated with intramedullary nails with high resolution. Therefore, RSA method can be used to evaluate new implant designs and clinical strategies, which aim to reduce cut-out complications. Future RSA studies should aim at more unstable fractures as these are more likely to fail with cut-out. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Femoral intertrochanteric nail (fitn): a new short version design with an anterior curvature and a geometric match study using post-operative radiographs.

    Science.gov (United States)

    Chang, Shi-Min; Hu, Sun-Jun; Ma, Zhuo; Du, Shou-Chao; Zhang, Ying-Qi

    2018-02-01

    Femoral intertrochanteric fractures are usually fixed with short, straight cephalomedullary nails. However, mismatches between the nail and the femur frequently occur, such as tip impingement and tail protrusion. The authors designed a new type of short femoral intertrochanteric nail (fitn) with an anterior curvature (length=19.5cm, r=120cm) and herein report the geometric match study for the first of 50 cases. A prospective case series of 50 geriatric patients suffering from unstable intertrochanteric fractures (AO/OTA 31 A2/3) were treated. There were 15 males and 35 females, with an average age of 82.3 years. Post-operatively, the nail entry point position in the sagittal greater trochanter (in three categories, anterior, central and posterior), the nail-tip position in the medullary canal (in 5-grade scale) and the nail-tail level to the greater trochanter (in 3-grade scale) were measured using X-ray films. For the nail entry point measurement, 5 cases were anterior (10%), 38 cases were central (76%), and 7 cases were posterior (14%). For the distal nail-tip position, 32 cases (64%) were located along the central canal axis, 13 cases (26%) were located anteriorly but did not contact the anterior inner cortex, 2 cases (4%) showed less than one-third anterior cortex thickness contact, and 3 cases (6%) were located posteriorly with no contact. For the proximal nail-tail level, there were no protrusions over the greater trochanter in 15 cases (30%), protrusion of less than 5mm in 29 cases (58%), and protrusion of more than 5mm in 6 cases (12%). The fitness was very high, as 96% cases showed no tip-cortex contact, and 88% cases showed less than 5mm proximal tail protrusion. The newly designed femoral intertrochanteric nail has a good geometric match with the femur medullary canal and the proximal length in the Chinese population. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Proximal femoral fractures: Principles of management and review of literature

    Science.gov (United States)

    Mittal, Ravi; Banerjee, Sumit

    2012-01-01

    Purpose The purpose of this study was to review the principles involved in the management of proximal femoral fractures as reported in the literature. Methods: A medical literature search in the MEDLINE (PubMed) and Cochrane database was undertaken to review strategies and principles in proximal femoral fracture treatment. Randomized control trials and meta analysis were given preference while case reports/small series were rejected. Results and conclusions: Early anatomical reduction and surgical fixation remains the best option to reduce the risk of complications like non-union and avascular necrosis in treating fracture neck femurs. Cancellous screws continue to be the preferred treatment for fixation of neck femur fractures in younger population until the benefit of using sliding hip screws is validated by large multicentric studies. In the geriatric age group, early prosthetic replacement brings down the mortality and morbidity associated with neck femur fractures. Sliding hip screw (DHS) is the best available option for stable inter trochanteric fractures. The use of intramedullary nails e.g. PFN is beneficial in treating inter trochanteric fractures with comminution and loss of lateral buttress. Intramedullary implants have been proven to have increased success rates in subtrochanteric fractures and should be preferred over extramedullary plate fixation systems. PMID:25983451

  12. Review of Proximal Nail Antirotation (PFNA and PFNA-2 – Our Local Experience

    Directory of Open Access Journals (Sweden)

    WL Loo

    2011-07-01

    Full Text Available The proximal femoral nail antirotation (PFNA device was recently introduced as an option for intramedullary management of pertrochanteric hip fractures. We report here local results with this relatively new implant. Sixty-two patients with pertrochanteric or subtrochanteric fractures underwent intramedullary fixation with PFNA devices in our centre during the 14 month period from September 2008 to October 2009. Data for this report were retrieved from clinical case records and operative notes. We recorded the age, gender, length of stay and operative time, preoperative ambulatory status and days required to regain mobility. Fractures were classified using the AO classification (A1, A2 and A3. Complications were also identified.There were 15 male and 47 female patients and the mean age was 74.3 years. The mean surgical duration was 76.1min and the average length of hospitalisation was 14.5 days. Five cases were noted to have femoral shaft fracture and no occurrences of screw cutout. We found that 83.9% of the patients were able to regain preoperative mobility status by 6 months following surgery. We conclude that the PFNA is an effective implant for stabilisation of proximal hip fractures and that the local complication rate is similar to reports from other centres.

  13. Surgery for pathological proximal femoral fractures, excluding femoral head and neck fractures: resection vs. stabilisation.

    Science.gov (United States)

    Zacherl, Max; Gruber, Gerald; Glehr, Mathias; Ofner-Kopeinig, Petra; Radl, Roman; Greitbauer, Manfred; Vecsei, Vilmos; Windhager, Reinhard

    2011-10-01

    Pathological femoral head and neck fractures are commonly treated by arthroplasty. Treatment options for the trochanteric region or below are not clearly defined. The purpose of this retrospective, comparative, double-centre study was to analyse survival and influences on outcome according to the surgical technique used to treat pathological proximal femoral fractures, excluding fractures of the femoral head and neck. Fifty-nine patients with 64 fractures were operated up on between 1998 and 2004 in two tertiary referral centres and divided into two groups. One group (S, n = 33) consisted of patients who underwent intramedullary nailing alone, and the other group (R, n = 31) consisted of patients treated by metastatic tissue resection and reconstruction by means of different implants. Median survival was 12.6 months with no difference between groups. Surgical complications were higher in the R group (n = 7) vs. the S group (n = 3), with no statistically significant difference. Patients with surgery-related complications had a higher survival rate (p = 0.049), as did patients with mechanical implant failure (p = 0.01). Survival scoring systems did not correlate with actual survival. Resection of metastases in patients with pathological fractures of the proximal femur, excluding femoral head and neck fractures, has no influence on survival. Patients with long postoperative survival prognosis are at risk of implant-related complications.

  14. The effects of intraoperative positioning on patients undergoing early definitive care for femoral shaft fractures.

    Science.gov (United States)

    Apostle, K L; Lefaivre, K A; Guy, P; Broekhuyse, H M; Blachut, P A; O'Brien, P J; Meek, R N

    2009-10-01

    To determine if there is a difference in morbidity and mortality in orthopaedic trauma patients with femoral shaft fractures undergoing early definitive care with intramedullary (IM) nails in the supine versus the lateral position. Retrospective cohort study, single centered. One level 1 trauma center. Nine hundred eighty-eight patients representing 1027 femoral shaft fractures treated with IM nails were identified through a prospectively gathered database between 1987 and 2006. Antegrade IM nail insertion with reaming of the femoral canal in either the supine or lateral position. Mortality was the primary outcome. Admission to intensive care unit (ICU) was the secondary outcome measure and a surrogate measure of morbidity. Literature review was performed to identify factors shown to contribute to morbidity and mortality in orthopaedic trauma patients. Intraoperative position in either the supine or lateral position was added to this list. Logistic regression analysis was performed to determine the magnitude and effect of the independent variables on each of the study end points. To determine if a more significant trend toward less favorable outcomes was observed with increasing severity of injury, particularly injuries of the chest and thorax, subgroup analysis was performed for all those with a femur fracture and an Injury Severity Score > or =18 and all those with a femur fracture and an Abbreviated Injury Score chest > or =3. Intraoperative position in either the supine or lateral position was not a significant predictor of mortality or ICU admission for the original cohort or the subgroup of Injury Severity Score > or =18. However, for the subgroup of Abbreviated Injury Score chest > or =3, intraoperative positioning in the lateral position had a statistically significant protective effect against ICU admission (P = 0.044). For polytrauma patients with femoral shaft fractures, surgical stabilization using IM nails inserted with reaming of the femoral canal in

  15. [Curative effect analysis on proximal frmoral nail antirotation for the treatment of femoral intertrochanteric fracture and integrity of lateral trochanteric wall].

    Science.gov (United States)

    Wei, Jie; Qin, De-an; Guo, Xiu-sheng

    2015-06-01

    To explore clinical efficacy and key matters for the treatment of femoral intertrochanteric fracture and integrity of lateral trochanteric wall by proximal frmoral nail antirotation (PFNA). From June 2010 to December 2012,210 femoral intertrochanteric fracture patients treated with PFNA were retrospectively analyzed, including 76 males and 134 females aged from 46 to 96 years old with an average of 71 years old. All fracture were caused by injury and classified to type I (5 cases) type II (16 cases), type III (73 cases) and type IV (116 cases) according to Evans classification. The time of getting out of bed, postoperative complications and displacement of screw blade and fracture healing were observed, Baumgaertner criteria were used to evaluate quality of fracture reduction, Harris criteria were used to evaulate hip joint function. All incisions were healed at stage I, no complications occurred except incomplete of lateral trochanteric wall patients without reconstruction, other patients could get out of bed with crutches at one week and all patients discharged from hospital at 10 days after operation. One hundred and seventy-eight patients were followed up from 3 to 17 months with an average of 10 months. One case occurred unhealed fracture displacement caused by screw blade cutting, 2 cases occurred screw blade transfomed to proximal and out femoral head, other patients obtained fracture healing at 12 to 16 weeks after operation. According to Baumgaertner criteria, 130 cases obtained good results, 45 cases acceptable, and 3 poor; while 107 cases obtained excellent results, 65 good, 3 good and 3 poor according to Harris score. PFNA with mechanical advantage of intramedullary fixation has advantsges of stable fixation, shorter operation time, minimally invasive. Satisfied clinical effects could obtained by grasping fixation principle, dealing with negative factors in operation. Intraoperative reconstruction for integrity of lateral trochanteric wall could assure

  16. Management of knee rheumatoid arthritis and tibia nonunion with one-stage total knee arthroplasty and intramedullary nailing: A report of two cases

    Directory of Open Access Journals (Sweden)

    Fahri Erdogan

    2018-01-01

    Full Text Available Total knee arthroplasty (TKA is a surgical procedure which is widely used in the treatment of gonarthrosis secondary to rheumatoid arthritis (RA. The incidence of stress fractures in tibia in the patients with RA is higher compared to normal patients. In this study, we report two cases of TKA and intramedullary nailing in RA patients with severe knee arthritis and tibial nonunion. Both patients had a satisfactory clinical outcome with radiological healing of the tibial fracture.

  17. The risk factors of perioperative hemoglobin and hematocrit drop after intramedullary nailing treatment for intertrochanteric fracture patients.

    Science.gov (United States)

    Wang, Jun; Wei, Jie; Wang, Manyi

    2015-01-01

    The objective of this study was to analyze the risk factors associated with the hemoglobin and hematocrit drops in the early postoperative period for intertrochanteric fracture patients with intramedullary nailing treatment. From January 2003 to December 2013, 634 intertrochanteric fracture patients with complete information were recruited into the study. Their age, gender, operating time, medical diseases, blood routine examination at admission and postoperative first day, and the days between the trauma and operation were recorded. The hemoglobin (HGB) change of patients (75 years) (P = 0.039). Meanwhile, the change of hematocrit (HCT) level of patients (75 years), but the difference was not significant (P = 0.062). The gender had no significant influence on HCT and HGB. The HGB and HCT change of patients with diabetes (ΔHCT, 8.47 ± 3.36 %; ΔHGB, 29.19 ± 13.10 g/l) were statistically greater than that of patients without diabetes (ΔHCT, 5.52 ± 3.84 %; ΔHGB, 19.81 ± 14.68 g/l) (P = 0.006, P = 0.022). The hypertension and coronary heart disease had no significant influence on the change of HCT and HGB levels. The operation time had a significant influence on the change of HCT and HGB. The ΔHCT and ΔHGB in the group for which the time was more than 48 h between the trauma and operation were greater than that in the group with less than 48 h between the trauma and operation but not significantly different (ΔHCT, P = 0.672; ΔHGB, P = 0.66). The factors of age, medical disease such as diabetes, operation time, and time between the trauma and operation may be associated with the change of perioperative hemoglobin and hematocrit levels for intertrochanteric fracture patients after intramedullary nailing treatment in the early postoperative period.

  18. [Intramedullary nailing of the distal tibia illustrated with the Expert(TM) tibia nail].

    Science.gov (United States)

    El Attal, R; Hansen, M; Rosenberger, R; Smekal, V; Rommens, P M; Blauth, M

    2011-12-01

    multicenter study. The follow-up rate was 81% after 1 year. Of these, 91 fractures (50.6%) were located in the distal third of the tibia. In this segment, the rate of delayed union was 10.6%. Malalignment of > 5° was observed in 5.4%. A secondary malalignment after initial good reduction was detected in only 1.1% of all cases. The implant-specific risk for screw breakage was 3.2%. One patient sustained a deep infection. If additional fibula plating was performed an 8-fold higher risk for delayed bone healing was observed (95%CI: 2.9-21.2, pfracture of the fibula was at the same height as on the tibia, the risk for delayed healing was even 14-fold (95% CI: 3.4-62.5, pfractures treated with an intramedullary nail. Using the ETN with its optimized locking options, fibula plating is not recommended, thus, avoiding soft tissue problems and potentially delayed bone healing.

  19. A Fast, Accurate and Easy to Implement Method for Pose Recognition of an Intramedullary Nail using a Tracked C-arm

    Directory of Open Access Journals (Sweden)

    H. Esfandiari

    2014-06-01

    Full Text Available A C-arm is a mobile X-ray device that is frequently used during orthopaedic surgeries. It consists of a semi-circular, arc-shaped arm that holds an X-ray transmitter at one end and an X-ray detector at the other. Intramedullary nail (IM nail fixation is a popular orthopaedic surgery in which a metallic rod is placed into the patient's fractured bone (femur or tibia and fixed using metal screws. The main challenge of IM-nail fixation surgery is to achieve the X-ray shot in which the distal holes of the IM nail appear as circles (desired view so that the surgeon can easily insert the screws. Although C-arm X-ray devices are routinely used in IM-nail fixation surgeries, the surgeons or radiation technologists (rad-techs usually use it in a trial-and-error manner. This method raises both radiation exposure and surgery time. In this study, we have designed and developed an IM-nail distal locking navigation technique that leads to more accurate and faster screw placement with a lower radiation dose and a minimum number of added steps to the operation to make it more accepted within the orthopaedic community. The specific purpose of this study was to develop and validate an automated technique for identifying the current pose of the IM nail relative to the C-arm. An accuracy assessment was performed to test the reliability of the navigation results. Translational accuracy was demonstrated to be better than 1 mm, roll and pitch rotations better than 2° and yaw rotational accuracy better than 2–5° depending on the separate angle. Computation time was less than 3.5 seconds.

  20. Prevention of excessive postoperative sliding of the short femoral nail in femoral trochanteric fractures.

    Science.gov (United States)

    Ito, Juji; Takakubo, Yuya; Sasaki, Kan; Sasaki, Junya; Owashi, Kazuya; Takagi, Michiaki

    2015-05-01

    Lag screw cut-out is one of the major postoperative complications on femoral trochanteric fractures. However, precise analyses of excessive sliding and lag screw cut-out were limited. The purpose of this study was to investigate the factors that induce this unfavorable event. From April 2010 to April 2013, 226 patients were operated in our institute using a short femoral nail. Among them, 177 patients (29 males and 148 females) with a mean age of 84 years (60-97 years), who were followed up >3 months, were included in this study. The postoperative sliding distance, fracture type (AO/OTA classification), tip-apex distance (TAD), reduction pattern in the postoperative X-ray (antero-posterior and lateral views), bone quality (canal flare and cortical indices), walking ability at the time of pre-injury and final follow-up, and complications were investigated retrospectively. The mean sliding distance was 3.7 mm, and one cut-out case (0.6 %) was observed. The sliding distance of the AO/OTA 31-A2 fractures was significantly longer than that of the A1 fractures (p fractures, an accurate reduction in the lateral view at surgery is important, particularly in unstable fractures.

  1. Augmentation of proximal femoral nail in unstable trochanteric fractures

    Directory of Open Access Journals (Sweden)

    Gadegone Wasudeo M.

    2017-01-01

    Full Text Available Introduction: Biomechanically proximal femoral nail (PFN is a better choice of implant, still it is associated with screw breakage, cut out of screw through femoral head, Z effect, reverse Z effect, and lateral migration of screws. The purpose of this study is to evaluate the results of augmented PFN in terms of prevention of postoperative complications and failure rates in unstable trochanteric fractures. Material and methods: We carried out a prospective study of 82 cases with unstable trochanteric femoral fractures from April 2010 to December 2015. Forty-two females and 40 males in the age group between 58 and 81 years were included in this study. There were 45 cases of AO 31 A2 (2.2, 2.3 and 37 cases of AO 31 A3 (3.1, 3.2, 3.3. Fractures were fixed by PFN with augmentation by an additional screw from trochanter to inferior quadrant of femoral head or cerclage wire to strengthen the lateral trochanteric wall. Results: The bone healing is observed in all the cases in the mean period of 14.2 weeks. Nine patients developed complications, including lateral migration of neck screws (n = 5, Z effect (n = 1, infection (n = 2, and breakage of distal interlocking bolt in one case. Removal of screws was required in five cases. Patients were followed up for a mean of 8.4 months. At the end of follow-up the Salvati and Wilson hip function was 32 (out of 40 in 88% of patients. Conclusion: The stabilization of lateral trochanteric wall with additional screw or cerclage wire increases the stability of construct.

  2. Unstable intertrochanteric femur fractures in geriatric patients treated with the DLT trochanteric nail.

    Science.gov (United States)

    Temiz, Aytun; Durak, Aslihan; Atici, Teoman

    2015-07-01

    To evaluate clinical-functional and radiological results of geriatric patients with unstable intertrochanteric femur fracture treated with intramedullary nail. Thirty-two patients treated with intramedullary nail (DLT trochanteric nail) due to unstable intertrochanteric femur fractures were reviewed retrospectively. Fractures 31-A2 and 31-A3 (AO classification) were evaluated. Operation time, blood loss, and blood transfusion requirements, hospitalization period, time to fracture union were evaluated and perioperative and postoperative complications were recorded. According to the modified Baumgaertner criteria fracture reduction was analyzed radiologically, and nail tip-apex distance was measured. Femoral neck-shaft angle was also evaluated. Harris Hip Score for clinical evaluation and Kyo criteria for walking capacity were used. The mean age was 72 years (65-81), mean follow up time was 18.3 months (12-26). Nineteen patients had type 31-A2 and 13 had type 31-A3 fractures. Mean operation time was 36.3min (25-45), blood loss 185.9ml (100-250). Blood transfusion was required in 7 patients. The average hospitalization duration was 6 days (4-14) while the time to surgery from admission was 2.9 days (2-6). Radiologically, in 21 of the cases fracture reduction was well (65.6%), acceptable in 9 (28.1%), and poor in 2 (6.3%). In early postoperative period, the mean collo-diaphyseal angle was 129.1° (120-140°), mean tip-apex distance was 15.5mm (10-27). The mean Harris Hip Score was 63.4 (38-90). Two patients (6.3%) had excellent, 21 patients (65.6%) had good, 7 patients (21.8%) had moderate, and 2 patients (6.3%) had poor results. Walking capacity in the last follow-up in 20 of the cases (62.5%) was pre-fracture level. While complications were observed in seventeen patients (53.1%) (5 superficial wound infections, 5 fractures of the greater trochanter, 3 cases of secondary varus angulation and 4 cases of heterotopic ossification) none of them required additional surgery

  3. Endomedullar nail of metacarpal and proximal phalanges

    International Nuclear Information System (INIS)

    Mendez Olaya, Francisco Javier; Sanchez Mesa, Pedro Antonio

    2002-01-01

    Prospective study, series of cases; it included patients with diaphysis fractures and union diaphysis-neck or union diaphysis-base of metacarpal and proximal phalanges, in whom was practiced anterograde intramedullary nailing previous closed reduction of the fracture, using prevent intramedullary nail of 1.6 mm. (cem 16) for the metacarpal fractures, and two nail prevent of 1.0 mm. (cem 10) for the proximal phalangeal fractures. Indications: transverse and oblique short fractures, spiral and with comminuting bicortical. Pursuit average is 5.7 months. Frequency surgical intervened patient: 2.2 each month, using this surgical technique a total of 20 (twenty) patients have been operated, 21 (twenty one) fractures; 16 (sixteen) metacarcal fractures and 5 (five) proximal phalangeal fractures, all of them tested using clinical and radiological parameters. Results: good 82%, regular 18%, and bad 0% obtaining bony consolidation and early rehabilitation with incorporation to their habitual works

  4. Effects of intramedullary nails composed of a new β-type Ti-Nb-Sn alloy with low Young's modulus on fracture healing in mouse tibiae.

    Science.gov (United States)

    Fujisawa, Hirokazu; Mori, Yu; Kogure, Atsushi; Tanaka, Hidetatsu; Kamimura, Masayuki; Masahashi, Naoya; Hanada, Shuji; Itoi, Eiji

    2018-01-23

    The influence of Young's moduli of materials on the fracture healing process remains unclear. This study aimed to assess the effects of intramedullary nails composed of materials with low Young's moduli on fracture repair. We previously developed a β-type Ti-Nb-Sn alloy with low Young's modulus close to that of human cortical bone. Here, we prepared two Ti-Nb-Sn alloys with Young's moduli of 45 and 78 GPa by heat treatment, and compared their effects on fracture healing. Fracture and nailing were performed in the right tibiae of C57BL/6 mice. The bone healing process was evaluated by microcomputed tomography (micro-CT), histomorphometry, and RT-PCR. We found larger bone volumes of fracture callus in the mice treated with the 45-GPa Ti-Nb-Sn alloy as compared with the 78-GPa Ti-Nb-Sn alloy in micro-CT analyses. This was confirmed with histology at day 14, with accelerated new bone formation and cartilage absorption in the 45-GPa Ti-Nb-Sn group compared with the 78-GPa Ti-Nb-Sn group. Acp5 expression was lower in the 45-GPa Ti-Nb-Sn group than in the 78-GPa Ti-Nb-Sn group at day 10. These findings indicate that intramedullary fixation with nails with a lower Young's modulus offer a greater capacity for fracture repair. Our 45-GPa Ti-Nb-Sn alloy is a promising material for fracture treatment implants. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2018. © 2018 Wiley Periodicals, Inc.

  5. Elastic stable intramedullary nailing is the best treatment of unicameral bone cysts of the long bones in children?: Prospective long-term follow-up study.

    Science.gov (United States)

    de Sanctis, Nando; Andreacchio, Antonio

    2006-01-01

    Since Virchow first described the unicameral bone cyst (UBC) in 1876, several methods for management were proposed. Currently performed surgical procedures include curettage combined with bone grafting, allografting with freeze-dried crushed cortical bone, use of homologous cancellous bone chips, the application of high-porosity hydroxyapatite, and cryosurgery. Decompression with multiple drill holes and intralesional injections of either steroids or bone marrow have also been used to treat UBC, with variable success rates. Elastic stable intramedullary nailing for the treatment of UBC in long bones has been rapidly gaining popularity. Elastic stable intramedullary nailing for the treatment of a UBC was performed in 56 patients between 1994 and 2003. The follow-up is between 2.1 and 11 years. Nine children were excluded because of short period of follow-up or were lost. The study population consisted of 47 children. The cyst was located in the humerus in 36 patients, in the femur in 11. The mean age of the patients at the time of surgery was 8.9 years. Results were evaluated on plain radiographs according to the classification system of Capanna et al. In our study population of 47 UBCs, 31 (65.9 %) were classified as completely healed, and 16 (34.1%) were healed with residual radiolucency. No recurrence or no response was observed. Each lesion responded to treatment after the nailing. This method can solve in time the pathology, and we feel that, with skilled hands, this method is the best one for UBC treatment in the long bones of the children.

  6. Treatment of femur fractures in young children: a multicenter comparison of flexible intramedullary nails to spica casting in young children aged 2 to 6 years.

    Science.gov (United States)

    Heffernan, Michael J; Gordon, J Eric; Sabatini, Coleen S; Keeler, Kathryn A; Lehmann, Charles L; O'Donnell, June C; Seehausen, Derek A; Luhmann, Scott J; Arkader, Alexandre

    2015-03-01

    Spica casting is the standard of care for femur fractures in children up to 6 years of age. The indications for surgery are controversial. We sought to compare immediate spica casting (Spica) and flexible intramedullary nailing [titanium elastic nailing (TEN)] in a group of children ages 2 to 6 years. We hypothesized that young children can be successfully treated with flexible nails, resulting in faster return to ambulation and an equivalent complication rate when compared with spica casting. This was a multicenter retrospective review of 215 patients, 141 treated with immediate spica casting, and 74 treated with elastic nails. Patient demographics, fracture characteristics, mechanism of injury, associated injuries, outcomes, and complications were recorded and compared between the 2 groups. Patients in the elastic nailing group were more likely to be injured as a pedestrian struck by an automobile (Spica 8% vs. TEN 26%, P=0.001), and had increased rates of associated injuries (Pcasting with shorter time to independent ambulation and full activities. Fractures associated with a high-energy mechanism are especially appropriate for consideration of treatment with TEN. Level III, this was a retrospective comparative study.

  7. The Results of the Treatment of Osteogenesis Imperfecta with Corkscrew Tipped Telescopic Nail

    Directory of Open Access Journals (Sweden)

    Hüseyin Günay

    2017-03-01

    Full Text Available Aim: We aimed to evaluate the clinical and radiological results of an intramedullary fixation system used in surgeries for fractures and deformities of osteogenesis imperfecta where we applied a new design corkscrew tipped intramedullary nailing. Materials and Methods: Twenty extremities of 14 osteogenesis cases, who underwent surgery and to whom corkscrew tipped intramedullary treatment was applied, were retrospectively scanned. Ambulation, discrepancies in the lenght of extremities, deformities and joint mobility range were all noted before the operation. Postoperative union rates, complications and our experience regarding the nail were also evaluated. Results: Six tibia and 14 femurs were operated using corkscrew tipped telescopic nails. Two bones were operated due to non-union, while seven bones underwent surgery due to acute fractures and 11 bones due to deformities. All the bones were seen to have achieved the aimed union. No major complications were observed. Infection was present in two cases. Conclusion: Corkscrew tipped telescopic nail is a safe and effective method of fixation in patients with osteogenesis imperfecta.

  8. Comparing two intramedullary devices for treating trochanteric fractures: A prospective study

    Directory of Open Access Journals (Sweden)

    Kontogeorgakos Vasileios

    2010-02-01

    Full Text Available Abstract Background Intertrochanteric fractures are surgically treated by using different methods and implants. The optional type of surgical stabilization is still under debate. However, between devices with the same philosophy, different design characteristics may substantially influence fracture healing. This is a prospective study comparing the complication and final functional outcome of two intramedullary devices, the intramedullary hip screw (IMHS and the ENDOVIS nail. Materials and methods Two hundred fifteen patients were randomized on admission in two treatment groups. Epidemiology features and functional status was similar between two treatment groups. Fracture stability was assessed according to the Evan's classification. One hundred ten patients were treated with IMHS and 105 with ENDOVIS nail. Results There were no significant statistical differences between the two groups regarding blood loss, transfusion requirements and mortality rate. In contrast, the number of total complications was significantly higher in the ENDOVIS nail group. Moreover, the overall functional and walking competence was superior in the patients treated with the IMHS nail. Conclusions These results indicate that the choice of the proper implant plays probably an important role in the final outcome of surgical treatment of intertrochanteric fractures. IMHS nail allows for accurate surgical technique, for both static and dynamic compression and high rotational stability. IMHS nail proved more reliable in our study regarding nail insertion and overall uncomplicated outcome.

  9. [Intramedullary stabilisation of clavicula fractures].

    Science.gov (United States)

    Prokop, A; Schiffer, G; Jubel, A; Chmielnicki, M

    2013-10-01

    With an incidence of 64/100,000, clavicular shaft fractures are one of the most common fractures. Intramedullary fixation with Prevot nails was initially reported in the late 1990s. This procedure offers minimally invasive stabilization of the fracture, thus enabling immediate mobilization and rapid loading capacity. Using a case study, the positioning and procedure are demonstrated on video. The intramedullary implant accommodates the varying tension loading of the clavicle. This treatment is ideal for clavicular fractures with 2-3 fragments. Compared to patients treated conservatively, operated patients achieve more rapid and improved mobility. Employment disability is shorter, and malunion occurs less frequently. Georg Thieme Verlag KG Stuttgart · New York.

  10. Femoral shaft bowing in the coronal plane has more significant effect on the coronal alignment of TKA than proximal or distal variations of femoral shape.

    Science.gov (United States)

    Kim, Jong-Min; Hong, Soo-Heon; Kim, Jong-Min; Lee, Bum-Sik; Kim, Dong-Eun; Kim, Kyung-Ah; Bin, Seong-Il

    2015-07-01

    The aim of this study was to determine (1) variations in the shape of the proximal, middle, and distal femur in a series of Korean patients who had undergone total knee arthroplasty (TKA), (2) the preoperative relationship between these three parameters and the distal valgus cutting angle referenced off the femoral intramedullary guide, and (3) whether there was any relationship between femoral bowing and variations in the shape of the proximal or distal femur in the coronal plane. The preoperative long-standing anteroposterior radiographs of 316 consecutive osteoarthritis patients who underwent primary TKA from 2009 to 2011 were examined. The femoral neck shaft angle, the femoral shaft bowing angle, and the mechanical lateral distal femoral angle were measured to assess the shape of the proximal, middle, and distal femur, respectively. The valgus cutting angle of the femur was defined as the angle between the distal anatomical and mechanical axes of the femur. The study population showed large variations in femoral shape. The mean femoral intramedullary guide angle was 6.5° ± 1.3° (range: 4°-13°). The femoral shaft bowing angle was the factor that showed the strongest correlation with this angle (P shaft angle showed no correlation (n.s.). The femoral shaft bowing angle showed a weak correlation with the mechanical lateral distal femoral angle (P = 0.001), but was not significantly correlated with the femoral neck shaft angle (n.s.). Apparent femoral bowing (>3° of lateral or medial bowing) was found in 42 (13.3 %) of cases (37 cases of lateral bowing and five of medial bowing). Cases with lateral apparent femoral bowing >3° had a distal cutting angle of 8.6° ± 2.2° relative to the femoral intramedullary guide. The femoral intramedullary guide angle was mainly influenced by femoral shaft bowing among femoral deformities in the coronal plane. Therefore, to increase the accuracy of distal femoral cut during TKA, it is necessary to confirm femoral

  11. Ipsilateral Femoral Fracture Non-Union and Delayed Union Treated By Hybrid Plate Nail Fixation and Vascularized Fibula Bone Grafting: A Case Report

    Directory of Open Access Journals (Sweden)

    CK Chan

    2013-07-01

    Full Text Available Non-union is a well recognized complication of femoral neck fractures. The decision whether to attempt fracture fixation or to resort to hip replacement is particularly difficult in patients in the borderline age group in whom complex attempts at gaining union may fail and later present a difficult revision. On the other hand the patient may be young enough that arthroplasty best be avoided . Besides, presence of ipsilateral femoral shaft fracture with delayed union in addition to the femoral neck non-union will pose major problems at operation. We share our experience in treating a femoral neck fracture non-union with ipsilateral femoral shaft delayed union in the shaft and in the distal femur in a fifty years old patient. The fracture was treated with an angle blade plate and supracondylar nail supplemented with a free vascularised fibular bone grafting and autologous cancellous graft. There was radiological union at fourth month. At sixth months, the patient was free of pain and able to walk without support. Thus, we would like to suggest that vascularised fibula bone grafting with supracondylar nailing is a viable option for this pattern of fracture.

  12. Management of Nonunited Talar Fractures With Avascular Necrosis by Resection of Necrotic Bone, Bone Grafting, and Fusion With an Intramedullary Nail.

    Science.gov (United States)

    Abd-Ella, Mohamed Mokhtar; Galhoum, Ahmed; Abdelrahman, Amr Farouk; Walther, Markus

    2017-08-01

    The presence of nonunion of a talar fracture with displacement, together with complete avascular necrosis, is a challenging entity to treat. Twelve patients, 8 men (66.7%) and 4 women (33.3%), with nonunited talar fractures and extensive avascular necrosis of the talus were included. The average age was 27.7 years (range, 19-38 years). After exclusion of infection, the patients underwent resection of necrotic bone, bulk autograft, and fusion using an intramedullary nail. The posterior approach was used in 11 patients and the anterior approach in 1 patient. The primary outcome was solid osseous union at the ankle and subtalar level and between the talar head anteriorly and the posterior construct, as evidenced by computed tomographic examination. Functional assessment was performed with the American Orthopaedic Foot & Ankle Society score and subjective patient satisfaction Results: After a mean follow-up duration of 23 months (range, 12-60 months), solid osseous union was achieved in 8 patients (66.7%). Stable fibrous union was seen in 1 patient (8.3%). Three patients (25%) required reoperation, and osseous fusion was finally achieved. American Orthopaedic Foot & Ankle Society score improved from a mean of 39.3 (range, 12-56) preoperatively to 76.6 (range, 62-86) at last follow-up. Subjective patient satisfaction was graded good or excellent in all cases. Resection of necrotic talar body and bulk autograft with tibiotalocalcaneal fusion by an intramedullary nail through a posterior approach was a reasonable option for the management of type IV posttraumatic talar deformity. Level IV, case series.

  13. Diaphyseal Fractures of the Forearm in Adults, Plating Or Intramedullary Nailing Is a Better Option for the Treatment?

    Directory of Open Access Journals (Sweden)

    Tabet A. Al-Sadek

    2016-11-01

    Full Text Available BACKGROUND: Fractures of the radius and ulna occupy a large field of the modern traumatology. Therefore, these fractures are a major subject in modern orthopaedics and traumatology. The study of the mechanisms of the trauma, and the pathophysiological changes that occur are of great importance for the development of ever more efficient and varied ways of the treatment and prophylactics of this type of fracture. AIM: The aim of this paper was to study the pattern of the diaphyseal fractures of the forearm in adults, to decide the modalities of surgical management, to observe the period of fracture healing clinically and radiologically, as well to study the rehabilitation of the patients. MATERIAL AND METHODS: The present study included 45 cases of diaphyseal fractures of both bones forearm in adults presenting to the orthopaedic outpatient department. For all the patients a detailed history was taken. A thorough clinical examination was carried out, required X-rays were taken, and initial treatment was given and admitted as in all patients. After careful pre-operative planning and evaluation for anaesthetic fitness, patients were operated for the fractures of both bone forearms. Twenty-three cases with 46 fractures were treated by open reduction and rigid fixation with DCP & Semi-tubular plates and 22 cases with 44 fractures were treated by closed reduction and fixation with “Talwarkar” intramedullary square nails. RESULTS: United results were found in 100% of plating group vs. 86% in the nailing group. Delayed and non-union results were found in 9% of the nailing group only. Average time to union in weeks was 9.4 weeks in the plating group vs. 10.2 weeks in the nailing group. CONCLUSION: Open reduction and internal fixation with compression plates with strict adherence to surgical technique is the gold standard method of treatment in both bones forearm fractures with excellent results than closed reduction, internal fixation with

  14. Median Nerve Palsy following Elastic Stable Intramedullary Nailing of a Monteggia Fracture: An Unusual Case and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Surjit Lidder

    2011-01-01

    Full Text Available Monteggia fractures are rare in children, and subtle radial head dislocations, with minor plastic deformation of the ulna, may be missed in up to a third of cases. Complications of Monteggia fractures-dislocations include persistent radial head dislocation, forearm deformity, elbow stiffness, and nerve palsies at the time of presentation. An unusual case of median nerve palsy following elastic stable intramedullary nailing of a type I Monteggia lesion in a 6-year-old girl is presented, and we highlight that, although most nerve palsies associated with a Monteggia fracture-dislocations are treated expectantly in children, early intervention here probably provided the best outcome.

  15. Do intramedullary implants improve survival in elderly patients with trochanteric fractures? A retrospective study.

    Science.gov (United States)

    Vermesan, D; Prejbeanu, R; Poenaru, D V; Petrescu, H; Apostol, E; Inchingolo, F; Dipalma, G; Abbinante, A; Caprio, M; Potenza, M A; Cagiano, R; Malcangi, G; Inchingolo, A D; Haragus, H

    2015-01-01

    There is currently no consensus regarding superiority of the intramedullary fixation over the sliding hip screw. Regional variation remains high and not backed up by solid evidence. Given these premises we aimed to analyze weather implant preference can influence the postoperative survival. Secondary objectives were determining the trend for implant choice and confounding factors associated with intramedullary nails compared to sliding hip screws. Retrospective data was obtained from patient charts with the main diagnosis of extracapsular/ trochanteric fractures, corresponding to ICD S72.1 codes. Between 2008-2012, 441 patients underwent osteosynthesis with a dynamic hip screw and 155 with intramedullary nail respectively. The living status was determined by comparing the patient identification number against the national population evidence records. The lifetable shows similar survival for both implants over the 5 year period. The yearly mortality was 19.4% for the dynamic hip screw and 21.8% for the intramedullary implant respectively, even though the later were used predominantly in older patients. This age difference is significant according to both parametric and non-parametric tests whereas duration of hospital stay are similar. We found a clear increase in the proportion of intramedullary implants, for a total of 11.2% over the 5 year period. There is no difference for the one year mortality and overall survival between sliding screw plates and intramedullary constructs. A clear increase in the use of intramedullary implants for trochanteric fractures was observed. This is even more apparent for older ages, presumably due to an higher surgeon confidence with the biomechanical stability of the intramedullary constructs.

  16. Treatment of a femoral shaft fracture in a patient with congenital hip disease: a case report

    Directory of Open Access Journals (Sweden)

    Koutsostathis Stefanos D

    2010-07-01

    Full Text Available Abstract Introduction We present a rare case of two concomitant morbidities treated in one operation. To our knowledge, this is the first report of its kind in the literature. Case presentation A 57-year-old Greek woman was admitted to the emergency department having sustained a spiral mid-shaft femoral fracture. She also suffered from an ipsilateral hip congenital dysplasia with ankylosed hip joint due to severe arthritis. She was treated with a total hip arthroplasty using a long stem performing as an intramedullary nail. Conclusion We undertook a complex operative treatment of both co-morbidities in a one stage procedure with a satisfactory clinical result.

  17. Utilization of the bicipital groove axis for confirming alignment of the humerus with transepicondylar and ulnar shaft axes during intramedullary nailing.

    Science.gov (United States)

    Meriç, Gökhan; Zeybek, Gülşah; Kıray, Amaç; Atik, Aziz; Budeyri, Aydın; Koşay, Can

    2015-01-01

    Intramedullary nailing is the preferred surgical treatment of humerus shaft fractures. The purpose of this study was to investigate the relationship between the bicipital groove and specific anatomical landmarks in achieving correct alignment of the humerus during intramedullary nailing, and to describe these anatomical landmarks. Thirty (15 right; 15 left) total upper cadaver extremities were used in this study. After the anatomical landmarks were identified and marked, humeral head axis, transepicondylar axis, ulnar shaft axis, bicipital groove axis, and angular measurements of these were obtained. The mean angle between the bicipital groove axis and transepicondylar axis was 48.17°±12.35º (range: 20.10º to 74.6º). The mean angle between the bicipital groove axis and ulna diaphysis axis was 41.82º±11.56 º (range: 17.91º to 68.27º). The mean angle between the humeral head axis and bicipital groove axis was 20.53°±3.90º (range: 11.85º to 31.81º). The mean retroversion angle between the humeral head axis and transepicondylar axis was 27.52±11.37º (range: 4.26º to 49.36º). The mean angle between the humeral head axis and ulna diaphysis axis was 61.73º±12.08º (range: 33.97º to 86.37º). The mean torsion angle was 62.58º±11.28 º (range: 40.74º to 85.74º). Measurement and utilization of the relationship between the bicipital groove, ulna diaphysis and transepicondylar axes may be used for restoring humeral rotation.

  18. Decreased QOL and muscle strength are persistent 1 year after intramedullary nailing of a tibial shaft fracture

    DEFF Research Database (Denmark)

    Larsen, Peter; Elsoe, Rasmus; Laessoe, Uffe

    2016-01-01

    was measured with the questionnaire Eq5D-5L and compared to norm data from a reference population. Recordings of pain and contralateral muscle strength (isometric maximal voluntary contraction (MVC) for knee flexion and extension were collected at 6 weeks, 3, 6, and 12 months postoperatively. Ipsilateral MVCs......INTRODUCTION:To evaluate the development in patient-reported quality of life (QOL) and muscle strength in the period from surgery to 12 months postoperatively after intramedullary nailing of a tibial shaft fracture. MATERIALS AND METHODS:The design was a prospective, follow-up cohort study. QOL...... compared to the reference population. Six and 12 months after surgery patients demonstrated decreased muscle strength in the injured leg compared to the non-injured leg for knee extension and flexion (P strength during knee...

  19. A comparison of locked versus nonlocked Enders rods for length unstable pediatric femoral shaft fractures.

    Science.gov (United States)

    Ellis, Henry Bone; Ho, Christine A; Podeszwa, David A; Wilson, Philip L

    2011-12-01

    Stainless steel flexible Enders rods have been used for intramedullary fixation of pediatric femur fractures with good success. Despite intraoperative anatomic alignment, length unstable femur fractures can present postoperatively with fracture shortening. The purpose of this study was to review all length unstable pediatric femoral shaft fractures in which Enders rods were used and compare those that were locked to those that were not locked. A retrospective clinical and radiographic review of all patients at a single institution undergoing flexible intramedullary fixation for length unstable femoral shaft fractures from 2001 to 2008. A length unstable fracture was defined as either a comminuted fracture or a spiral fracture longer than twice the diameter of the femoral shaft. A total of 107 length unstable femoral shaft fractures fixed with Enders rods were identified, of which 37 cases (35%) had both Enders rods "locked" through the eyelet in the distal femur with a 2.7 mm fully threaded cortical screw. Patient demographics, clinical course, complications, fracture characteristics, and radiographic outcomes were compared for the locked and nonlocked groups. There were no statistical differences between the groups in demographic data, operative variables, fracture pattern, fracture location, time to union, femoral alignment, or major complications. Shortening of the femur and nail migration measured at 1 to 6 weeks postoperatively was significantly greater for the nonlocked cases. The medial and lateral locked Enders rods moved 1.3 and 1.9 mm, respectively, and the unlocked Enders each moved 12.1 mm (P < 0.05). At final follow-up there were significantly more (P < 0.05) clinical complaints in nonlocked group, including limp, clinical shortening, and painful palpable rods. Locking Enders rods for length unstable pediatric fractures is an excellent option to prevent shortening and resulted in no additional complications, added surgical time, or increased blood loss

  20. Close Intramedullary Interlocking Nailing Versus Locking Compression Plating In the Treatment of Closed Fracture Shaft of the Tibia.

    Science.gov (United States)

    Kundu, I K; Datta, N K; Chowdhury, A Z; Das, K P; Tarik, M M; Faisal, M A

    2016-07-01

    Fracture of tibial shaft is the commonest site of long bone fractures due to its superficial location involving young or middle-age people. Proper management is an important issue regarding the future effective movements. In this study patients were grouped in closed Intra medullary interlocking nailing and locking compression plating. Post-operative follow up at 2 weeks, 6 weeks, 12 weeks and 3 months thereafter up to 6 months were done. Each of the patients was evaluated clinically and radiologically by tucker criteria of Tuker et al. Patients were assessed for pain on full weight bearing and kneeling, shortening and range of motion of knee and ankle joints. Radiological assessment for union of fracture, alignment of fracture and angulations and position of nail and screws and infection were observed during follow up. A total number of 32 patients were selected but only 27 patients were available for follow up for a period of 6 months. They were grouped into Group A, consisting of 15 patients who took the treatment in the form of closed intramedullary interlocking nailing and Group B, consisting of 12 patients those underwent ORIF with locking compression plating. In both of the groups Motor Vehicle Accident was the main mechanism of trauma. Fracture involving the middle 3rd of the tibia is common in both the groups. During post-operative follow up, four patients in Group A complained anterior knee pain, one patient in Group B had superficial infection, most of the patients had no restriction of movement in the ankle and knee joints and a single patient in Group B showed 1.5cm shortening of the lower limb. Period of hospital stay and fracture union time were less in Group A, which was statistically significant. Both groups showed excellent result with minimum complications. So this study permits to conclude that close IM interlocking nailing and open reduction and internal fixation by locking compression plating is equally effective for the management of close

  1. Development of a fixation device for robot assisted fracture reduction of femoral shaft fractures: a biomechanical study.

    Science.gov (United States)

    Weber-Spickschen, T S; Oszwald, M; Westphal, R; Krettek, C; Wahl, F; Gosling, T

    2010-01-01

    Robot assisted fracture reduction of femoral shaft fractures provides precise alignment while reducing the amount of intraoperative imaging. The connection between the robot and the fracture fragment should allow conventional intramedullary nailing, be minimally invasive and provide interim fracture stability. In our study we tested three different reduction tools: a conventional External Fixator, a Reposition-Plate and a Three-Point-Device with two variations (a 40 degrees and a 90 degrees version). We measured relative movements between the tools and the bone fragments in all translation and rotation planes. The Three-Point-Device 90 degrees showed the smallest average relative displacement and was the only device able to withstand the maximum applied load of 70 Nm without failure of any bone fragment. The Three-Point-Device 90 degrees complies with all the stipulated requirements and is a suitable interface for robot assisted fracture reduction of femoral shaft fractures.

  2. Presence of a nail in the medullary canal; is it enough to prevent femoral neck shortening in trochanteric fracture?

    Science.gov (United States)

    Song, Hyung Keun; Yoon, Han Kuk; Yang, Kyu Hyun

    2014-09-01

    Presence of a cephalomedullary nail (CMN) in the medullary canal has been thought as advantageous in the control of femoral neck shortening (FNS) and lag screw sliding in trochanteric fracture compared to extramedullary fixation system. However, researches on the factors that influence the degree of FNS after cephalomedullary nailing are lacking. We observed 95 patients (mean age, 75±2.8 years) with trochanteric fractures who were treated with a CMN, and evaluated the relationship between FNS and patient factors including age, gender, fracture type (AO/OTA), bone mineral density, medullary canal diameter, canal occupancy ratio (COR=nail size/canal diameter), and tip-apex distance using initial, immediate postoperative, and follow-up radiography. Univariate regression analyses revealed that the degree of FNS was significantly correlated with fracture type (A1 versus A3, pfracture type (pfracture.

  3. a simple technique for on-table confirmation of locking screw ...

    African Journals Online (AJOL)

    2012-09-06

    Sep 6, 2012 ... Background: Locked intramedullary nailing is the standard of care for femoral and tibial shaft fractures. Correct placement of locking ... It can be used with any cannulated nailing system. It is simple, in-expensive and ... include computer assisted navigation systems (3), as well as use of devices that use a ...

  4. reoperation rates following intramedullary nailing versus external

    African Journals Online (AJOL)

    Results: Fifty patients were enrolled and completed follow-up at all-time points; twenty-six were treated with IM nail and ... patients over 18 years with Gustilo Type 3A open tibia .... in a randomized fashion with larger sample sizes are.

  5. Fracture Union in Closed Interlocking Nail in Humeral Shaft Fractures

    Directory of Open Access Journals (Sweden)

    Ramji Lal Sahu

    2015-01-01

    Conclusions: The results of the present study indicates that in the presence of proper indications, reamed antegrade intramedullary interlocked nailing appears to be a method of choice for internal fixation of osteoporotic and pathologic fractures.

  6. Subtrochanteric femoral fractures treated with the Long Gamma3® nail: A historical control case study versus Long trochanteric Gamma nail®.

    Science.gov (United States)

    Georgiannos, D; Lampridis, V; Bisbinas, I

    2015-10-01

    Gamma nail was developed for the treatment of subtrochanteric hip fractures. Despite its advantages over extramedullary devices, gamma nail has been historically related to significant complications (implant breakage, femoral fractures at the tip of the nail). There is limited data to determine if the rate of these complications was minimized by using a new design of the gamma nail. Therefore we performed a case control study between the long gamma3 nail (LG3N) and the long trochanteric gamma nail (LTGN) to assess if: (1) the complication rate in the treatment of subtrochanteric fractures using the LG3N was lower than the one using the LTGN; (2) the reoperation rate was lower after using the LG3N. The complication rate after fixation of subtrochanteric fracture of the femur is lower with LG3N than with the LTGN. This study prospectively recorded the intra- and postoperative complications of 75 patients with subtrochanteric fractures treated with the LG3N and compared them with those of a historical cohort of 83 patients treated with the LTGN. The two groups were matched regarding age, gender and fracture type. Patients with open, pathological, or impending fractures were excluded. Intraoperative complications in the LG3N group were lower (4 cases, 5.3%) compared with those in the LTGN group (9 cases, 10.8%; P=0.04). The major intraoperative complication encountered with the use of LTGN was fracture of the femur in 3 cases. We encountered in total 9 postoperative complications in LG3N (12%) and 20 in group LTGN (24%). The most frequent complication in both groups was the cut out of the lag screw (3 cases in LG3N and 7 cases in LTGN group). The overall reoperation rate was higher in LTGN group (20.4% vs 10.6%; P=0.03). As a result of the improvement of its mechanical characteristics, LG3N has proved a safe and efficient implant for the treatment of subtochanteric fractures. The new design seems superior to previous generation, giving promising outcomes, reduced

  7. High revision rate but good healing capacity of atypical femoral fractures. A comparison with common shaft fractures.

    Science.gov (United States)

    Schilcher, Jörg

    2015-12-01

    Healing of complete, atypical femoral fractures is thought to be impaired, but the evidence is weak and appears to be based on the delayed healing observed in patients with incomplete atypical fractures. Time until fracture healing is difficult to assess, therefore we compared the reoperation rates between women with complete atypical femoral fractures and common femoral shaft fractures. We searched the orthopaedic surgical registry in Östergötland County for patients with subtrochanteric and femoral shaft fractures (ICD-10 diagnosis codes S72.2, S72.3 and M84.3F) between January 1st 2007 and December 31st 2013. Out of 895 patients with surgically treated femoral shaft fractures, 511 were women 50 years of age or older. Among these we identified 24 women with atypical femoral shaft fractures, and 71 with common shaft fractures. Reoperations were performed in 6 and 5 patients, respectively, odds ratio 4.4 (95% CI 1.2 to 16.1). However, 5 reoperations in the atypical fracture group could not be ascribed to poor healing. In 3 patients the reoperation was due to a new fracture proximal to a standard intramedullary nail. In 2 patients the distal locking screws were removed due to callus formation that was deemed incomplete 5 months post-operatively. The one patient with poor healing showed faint callus formation at 5 months when the fracture was dynamised and callus remained sparse at 11 months. Among patients with common shaft fractures, 2 reoperations were performed to remove loose screws, 2 because of peri-implant fractures and 1 reoperation due to infection. Reoperation rates in patients with complete atypical femoral fractures are higher than in patients with common shaft fractures. The main reason for failure was peri-implant fragility fractures which might be prevented with the use of cephalomedullary nails at the index surgery. Fracture healing however, seems generally good. A watchful waiting approach is advocated in patients with fractures that appear to

  8. [Tibio-talo-calcaneal arthrodesis with the retrograde intramedullary nail MEDIN].

    Science.gov (United States)

    Popelka, S; Vavřík, P; Landor, I; Bek, J; Popelka ml, S; Hromádka, R

    2013-01-01

    When the talus and the talocalcaneal joint are both affected, their fusion is the method of treatment. Ankle arthrodesis is carried out using various osteosynthetic materials such as external fixators, screws and plates. One of the options is retrograde nailing. Tibio-talo-calcaneal arthrodesis is frequently indicated in patients with rheumatoid arthritis (RA) in whom both the talus and the subtalar joint are often affected. A retrograde nail for tibio-talo-calcaneal arthrodesis was developed at our department in cooperation with MEDIN Company. This is a titanium double-curved nail, with the distal part bent at 8 degrees ventrally and 10 degrees laterally. It is inserted from the transfibular approach. Sixty-two patients, 35 women and 27 men, were treated at our department from 2005. Since one patient had bilateral surgery, 63 ankles were included. The indications for arthrodesis involved rheumatoid arthritis in 42, post-traumatic arthritis in 10, failed ankle arthrodesis in two and failed total ankle arthroplasty in five ankles; tibial stress fractures close above the ankle in two RA patients, one patient with dermatomyositis and one with lupus erythematodes. The average age at the time of surgery was 64.2 years (range, 30 to 80). The average follow-up was 4.5 years (range, 1 to 9 years), Satisfaction with the treatment outcome and willingness to undergo surgery on the other side were reported by 82% of the patients. The AOFAS score improved from 35 to 74 points. Three (4.8%) patients complained of painful feet due to the fact that exact correction of the calcaneus was not achieved and the heel after arthrodesis remained in a slightly varus position. Of them, two had a failed total ankle arthroplasty. Post-operative complications included early infection managed by antibiotic treatment and early surgical revision with irrigation.in two (3.2%) RA patients, who were undergoing biological therapy. Late infection developed at 2 to 3 years after surgery in three (4

  9. The treatment of subtrochanteric fractures

    Directory of Open Access Journals (Sweden)

    Vučetić Čedomir S.

    2011-01-01

    Full Text Available Subtrochanteric fractures of the femur have a special place because of a significant number of complications following treatment. Powerful loading forces asymmetrically acting to this bone segment, as well as poor vascularization interfere with bone union. There are basically two current approaches in the fixation of subtrochanteric fractures; the first involves a plate with a compression screw and another one is intramedullary (IM nail, with two options: centromedullary (standard interlocking femoral nail and cephalomedullary femoral nail with two modifications, reconstructive and trochanteric. All IM nails may be used by open technique or closed minimal invasive method. IM nailing is favoured in view of a shorter operative time, shorter hospitalisation and complications. Indirect fracture reduction and knowledge of biology of bone fracture may result in full success without any bone graft.

  10. Pseudoaneurysm of the deep femoral artery caused by a guide wire following femur intertrochanteric fracture with a hip nail: A case report

    Directory of Open Access Journals (Sweden)

    Ji Wan Kim

    2017-05-01

    Full Text Available An 85-year-old woman developed severe swelling and pain in the proximal thigh after internal fixation of an intertrochanteric fracture of the femur with a hip nail. In order to identify the causes and determine the effective treatment, angiography was performed. The results of the angiography revealed a pseudoaneurysm of a branch of deep femoral artery. Endovascular embolization was used to treat the pseudoaneurysm. After reviewing all possible causes, we found a mistake in insertion of a guide wire for hip nail. Using intraoperative fluoroscopic images, we found the mal-positioned guide wire located posterior to trochanter on lateral view of hip. This case study reminds us that pseudoaneurysm can occur in a guide wire during hip nailing. Surgeons can avoid this complication with confirmation of lateral and anteroposterior view of hip.

  11. Static bending test after proximal femoral nail (PFN removal - in vitro analysis

    Directory of Open Access Journals (Sweden)

    Leonardo Morais Paiva

    Full Text Available Abstract Objective To evaluate, through biomechanical testing, the resistance to and energy required for the occurrence of proximal femoral fracture in synthetic bone after removal of a proximal femoral nail model (PFN, comparing the results obtained with a reinforcement technique using polymethylmethacrylate (PMMA. Methods Fifteen synthetic bones were used: five units for the control group (CG, five for the test group without reinforcement (TGNR, and five for the test group with reinforcement (TGR. The biomechanical analysis was performed simulating a fall on the trochanter using a servo-hydraulic machine. In the GC, the assay was performed with the PFN intact. In the TGNR and TGR groups, a model of PFN was introduced and the tests were performed in the TGNR, after simple removal of the synthesis material, and in the TGR, after removal of the same PFN model and filling of the cavity in the femoral neck with PMMA. Results All groups presented a basicervical fracture. The CG presented a mean of 1427.39 Newtons (N of maximum load and 10.14 Joules (J of energy for the occurrence of the fracture. The TGNR and TGR presented 892.14 N and 1477.80 N of maximum load, and 6.71 J and 11.99 J of energy, respectively. According to the Kruskal-Wallis ANOVA, there was a significant difference in the maximum load (p = 0.009 and energy (p = 0.007 between these groups. Conclusion The simple removal of a PFN in synthetic bone showed a significant reduction of the maximum load and energy for the occurrence of fracture, which were re-established with a reinforcement technique using PMMA.

  12. Retrograde nailing for distal femur fractures in the elderly

    Directory of Open Access Journals (Sweden)

    Giddie Jasdeep

    2015-01-01

    Full Text Available Introduction: We report the results of treating a series of 56 fractures in 54 elderly patients with a distal femur fracture with a retrograde femoral nail. Methods: Fifty-four of the nails were inserted percutaneously with a closed reduction. After surgery all patients were allowed to weight bear as tolerated. Four fractures were supported in a temporary external splint. Results: The mean age of patients was 80.6 years (range 51–103 years, 52/54 (96% were females. There were no cases of nail related complications and no re-operations were required. One patient was lost to follow up. The 30-day mortality was 5/54 (9.3% and the one year mortality was 17/54 (31.5%. Conclusions: Distal femoral nail fixation provides a good method of fixation allowing immediate mobilisation for this group of patients.

  13. Outcome of surgical implant generation network nail initiative in ...

    African Journals Online (AJOL)

    in Uganda, was propagated in to Kenya mainly in resource poor hospitals, and has changed long bone fractures' management and outcomes. The goal of this study was to describe applicability of the SIGN initiative in fracture care in a Kenyan hospital. AbstrAct. Background: Closed interlocked intra-medullary nailing (IM), ...

  14. A STUDY OF THE MANAGEMENT OF OPEN FRACTURES OF TIBIA BY UNREAMED INTERLOCKING NAIL

    Directory of Open Access Journals (Sweden)

    Kuppa Srinivas

    2015-01-01

    Full Text Available AIMS AND OBJECTIVES: To evaluate the results of closed interlocking intramedullary nailing without reaming in the treatment of open fractures of t he tibial shaft and study the difficulties (complications encountered during the operative study. To compare the efficacy of interlocking intramedullary nailing without reaming in treating open fractures of tibia, Time required for the union of fracture, Range of motion of ankle and knee joint, Rate of malunion and mal rotation and Pain at the knee joint. RESULTS: The average age of patient is 32 years,83.33% are males, road traffic accidents account for majority(79.16%,right side involved in 58.33%,gustillo type II and type I compound fractures are common, full range of movements is seen in 66.67% by 12 weeks and union occurred in 95.83% by 9 months. Thirteen (54.17% patients had excellent results, six (25% patients had good results, four (1 6.67% patients had fair results and one (4.16 patient had poor result. CONCLUSION: Unreamed interlocking intramedullary nailing with the help of image intensifier seems feasible in open diaphyseal fractures of tibia with the advantages of minimal blood l oss, low risk of infection, early mobilisation , earlier soft tissue coverage , Promotes early union , minimal hospital stay and early returns to activities

  15. Ingenious method of external fixator use to maintain alignment for nailing a proximal tibial shaft fracture.

    Science.gov (United States)

    Behera, Prateek; Aggarwal, Sameer; Kumar, Vishal; Kumar Meena, Umesh; Saibaba, Balaji

    2015-09-01

    Fractures of the tibia are one of the most commonly seen orthopedic injuries. Most of them result from a high velocity trauma. While intramedullary nailing of tibial diaphyseal fractures is considered as the golden standard form of treatment for such cases, many metaphyseal and metaphyseal-diaphyseal junction fractures can also be managed by nailing. Maintenance of alignment of such fractures during surgical procedure is often challenging as the pull of patellar tendon tends to extend the proximal fragment as soon as one flexes the knee for the surgical procedure. Numerous technical modifications have been described in the literature for successfully nailing such fractures including semi extended nailing, use of medial plates and external fixators among others. In this study, it was aimed to report two cases in which we used our ingenious method of applying external fixator for maintaining alignment of the fracture and aiding in the entire process of closed intramedullary nailing of metaphyseal tibial fractures by the conventional method. We were able to get good alignment during and after the closed surgery as observed on post-operative radiographs and believe that further evaluation of this technique may be of help to surgeons who want to avoid other techniques.

  16. [Intramedullary nailing of the tibia with the expert tibia nail].

    Science.gov (United States)

    Hansen, Matthias; El Attal, René; Blum, Jochen; Blauth, Michael; Rommens, Pol Maria

    2009-12-01

    Restoration of axis, length, and rotation of the lower leg. Sufficient primary stability of the osteosynthesis for functional aftercare. Early functional aftercare to maintain joint mobility. Good bony healing in closed and open fractures. All closed and open fractures of the tibia and complete lower leg fractures (AO 42). Certain extraarticular fractures of the proximal and distal tibia (AO 41 A2/A3; AO 43 A1/A2/A3). Segmental fractures of the tibia. Certain intraarticular fractures of the tibia with use of additional implants (AO 41 C1/C2; AO 43 C1/C2). Stabilization during and after segmental bone transport or callus distraction of the tibia. Patients in poor general condition (e.g., bedridden). Flexion of the knee of less than 90 degrees . Infection in the nail's insertion area. Infection of the tibial cavity. Complex articular fractures of the proximal or distal tibia with joint depression. Closed reduction of the fracture. If necessary, use of reduction clamps through additional stab incisions or open surgical procedures. In some cases, additional osteosynthesis procedures are necessary (e.g., screws). Positioning of the patient may be performed on a radiolucent table or a traction table. Opening of the proximal tibia in line with the medullary canal. Cannulated or noncannulated insertion of the Expert Tibia Nail((R)) with or without reaming of the medullary canal depending on the fracture type and soft-tissue condition. Control of axis, length, and rotation. Distal interlocking with the radiolucent drill and proximal interlocking with the targeting device. Immediate mobilization of ankle joint and knee joint. Depending on the type of fracture, mobilization with 20 kg partial weight bearing or pain-dependent full weight bearing with crutches. X-ray control 6 weeks postoperatively and increased weight bearing depending on the fracture status. In a prospective, international multicentric study, 181 patients with 186 fractures were included between July 2004 and

  17. Hindfoot Valgus following Interlocking Nail Treatment for Tibial Diaphysis Fractures: Can the Fibula Be Neglected?

    Directory of Open Access Journals (Sweden)

    Metin Uzun

    2014-01-01

    Full Text Available Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated fibular fractures, except the distal one-third level, were included in this study. All tibial shaft fractures were anatomically reduced and fixed with interlocking intramedullary nails. Fibular fractures were managed conservatively. Hindfoot alignment was assessed clinically. Tibia and fibular lengths were compared to contralateral measurements using radiographs. Functional results were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS and the Foot and Ankle Disability Index Score (FADI. Results. Anatomic union, defined as equal length in operative and contralateral tibias, was achieved in 60 fractures (100%. Fibular shortening was identified in 42 fractures (68%. Mean fibular shortening was 1.2 cm (range, 0.5–2 cm. Clinical exams showed increased hindfoot valgus in 42 fractures (68%. The mean KOOS was 88.4, and the mean FADI score was 90. Conclusion. Fibular fractures in the middle or proximal one-third may need to be stabilized at the time of tibial intramedullary nail fixation to prevent development of hindfoot valgus due to fibular shortening.

  18. A biomechanical evaluation of proximal femoral nail antirotation with respect to helical blade position in femoral head: A cadaveric study

    Directory of Open Access Journals (Sweden)

    Jin-Ho Hwang

    2012-01-01

    Full Text Available Objective: Despite new developments in the management of osteoporotic fractures, complications like screw cutout are still found in the fixation of proximal femur fractures even with biomechanically proven better implants like proximal femoral nail antirotation (PFNA. The purpose of this cadaveric study was to investigate the biomechanical stability of this device in relation to two common positions (center-center and inferior-center of the helical blade in the femoral head in unstable trochanteric fractures. Materials and Methods: Eight pairs of human cadaveric femurs were used; in one group [center-center (C-C group], the helical blade of PFNA was fixed randomly in central position both in anteroposterior and lateral view, whereas in the other group it was fixed in inferior one-third position in anteroposterior and in central position in lateral view [inferior-center (I-C group]. Unstable intertrochanteric fracture was created and each specimen was loaded cyclically till load to failure Results: Angular and rotational displacements were significantly higher within the C-C group compared to the I-C group in both unloaded and loaded condition. Loading to failure was higher in the I-C group compared to the C-C group. No statistical significance was found for this parameter. Correlations between tip apex distance, cyclic loading which lead to femoral head displacement, and ultimate load to failure showed a significant positive relationship. Conclusion: The I-C group was superior to the C-C group and provided better biomechanical stability for angular and rotational displacement. This study would be a stimulus for further experimental studies with larger number specimens and complex loading protocols at multicentres.

  19. Trochanteric fragility fractures : Treatment using the cement-augmented proximal femoral nail antirotation.

    Science.gov (United States)

    Neuerburg, C; Mehaffey, S; Gosch, M; Böcker, W; Blauth, M; Kammerlander, C

    2016-06-01

    Use of standardized cement augmentation of the proximal femur nail antirotation (PFNA) for the treatment of trochanteric fragility fractures, which are associated with high morbidity and mortality, to achieve safer conditions for immediate full weight-bearing and mobilization, thus, improving preservation of function and independency of orthogeriatric patients. Trochanteric fragility fractures (type 31-A1-3). Ipsilateral arthritis of the hip, leakage of contrast agent into the hip joint, femoral neck fractures. Reduction of the fracture on a fracture table if possible, or minimally invasive open reduction of the proximal femur, i. e., using collinear forceps if necessary. Positioning of guidewires for adjustment of the PFNA and the spiral blade, respectively. Exclusion of leakage of contrast agent and subsequent injection of TRAUMACEM™ V(+) into the femoral head-neck fragment via a trauma needle kit introduced into the spiral blade. Dynamic or static locking of the PFNA at the diaphyseal level. Immediate mobilization of the patients with full weight-bearing and secondary prevention, such as osteoporosis management is necessary to avoid further fractures in the treatment of these patients. A total of 110 patients older than 65 years underwent the procedure. Of the 72 patients available for follow-up (average age 85.3 years), all fractures healed after an average of 15.3 months. No complications related with cement augmentation were observed. Approximately 60 % of patients achieved the mobility level prior to trauma.

  20. 3066 consecutive Gamma Nails. 12 years experience at a single centre

    Directory of Open Access Journals (Sweden)

    Ekholm Carl

    2010-06-01

    Full Text Available Abstract Background Fixation of trochanteric hip fractures using the Gamma Nail has been performed since 1988 and is today well established and wide-spread. However, a number of reports have raised serious concerns about the implant's complication rate. The main focus has been the increased risk of a subsequent femoral shaft fracture and some authors have argued against its use despite other obvious advantages, when this implant is employed. Through access to a uniquely large patient data base available, which is available for analysis of trochanteric fractures; we have been able to evaluate the performance of the Gamma Nail over a twelve year period. Methods 3066 consecutive patients were treated for trochanteric fractures using Gamma Nails between 1990 and 2002 at the Centre de Traumatologie et de l'Orthopedie (CTO, Strasbourg, France. These patients were retrospectively analysed. Information on epidemiological data, intra- and postoperative complications and patients' outcome was retrieved from patient notes. All available radiographs were assessed by a single reviewer (AJB. Results The results showed a low complication rate with the use of the Gamma Nail. There were 137 (4.5% intraoperative fracture-related complications. Moreover 189 (6.2% complications were detected postoperatively and during follow-up. Cut-out of the lag screw from the femoral head was the most frequent mechanical complication (57 patients, 1.85%, whereas a postoperative femoral shaft fracture occurred in 19 patients (0.6%. Other complications, such as infection, delayed healing/non-union, avascular femoral head necrosis and distal locking problems occurred in 113 patients (3.7%. Conclusions The use of the Gamma Nail in trochanteric hip fractures is a safe method with a low complication rate. In particular, a low rate of femoral shaft fractures was reported. The low complication rate reported in this series can probably be explained by strict adherence to a proper

  1. Serious anaphylactic shock induced by hemocoagulase agkistrodon during anesthesia in a 5-year-old child.

    Science.gov (United States)

    Xu, Ying-Yi; Li, Bi-Lian; Jin, Yu-Lin; Wang, Zi-Xin; Song, Xing-Rong; Ni, Jin

    2015-01-01

    We report a case of serious anaphylactic shock in a 5-year-old child undergoing scheduled surgery blank space of a right femoral intramedullary nail removal. The boy had undergone right femoral elastic intramedullary nail fixation surgery 14 months prior, but had no history of allergies. Within 5 minutes of intravenous bonus injection of hemocoagulase agkistrodon (HCA) 1 unit, a widespread transient diffuse erythema was seen on the front of his chest. After 20 minutes, sudden, profound cardiovascular collapse occurred. The child was treated effectively and sent to a ward 5 hours later. In this period, he received intravenously infused 200 ml hydroxyethyl starch solution and epinephrine at a rate of 0.05-0.01 μg kg(-1) min(-1). Total amount of dexamethasone sodium phosphate 14 mg was used. To the best of our knowledge, few case reports of HCA-induced anaphylactic shock in children exist. Our report will, therefore, increase awareness of the allergic potential of HCA among pediatric anesthesiologists.

  2. Do PFNA devices and Intertan nails both have the same effects in the treatment of trochanteric fractures? A prospective clinical study.

    Science.gov (United States)

    Seyhan, Mustafa; Turkmen, Ismail; Unay, Koray; Ozkut, Afsar Timucin

    2015-11-01

    To clinically and radiologically compare third-generation intramedullary nails used in the treatment of trochanteric hip fractures and to determine their efficacy. Seventy-five of 88 patients admitted to our hospital with trochanteric fractures were enrolled in the study; 43 were treated with PFNA devices and 32 with Intertan nails. The amount of compression applied during the procedure, duration of the procedure, amount of subsequent shortening in the proximal femoral area, subsequent backup of proximal screws, and changes in the tip-apex and tip-cortex distances were compared between groups. The postoperative change in the varus angle of the proximal femur and times to mobilization, full weight bearing, and fracture union were also evaluated. On early postoperative radiographs, the tip-apex distance was ≤25 mm in 86 % of patients in the PFNA group and 96.9 % of those in the Intertan group. Twelve months postoperatively, the tip-apex distance did not differ between groups. No cut-out of the screws into the coxofemoral joint was observed. Fracture healing was achieved in all patients. At 12 months postoperatively, the rates of proximal screw backup, proximal femoral shortening, and decrease in the varus angle of the proximal femur were significantly higher in the PFNA group than in the Intertan group. Trochanteric fractures may be treated effectively with PFNA devices or Intertan nails. During the healing period, the rates of reverse displacement of the proximal screw, shortening of the proximal femur, and decrease in the varus angle of the proximal femur were significantly higher in the PFNA group than in the Intertan group. Surgical technique, implant positioning, and the choice of implant play roles in the successful treatment of trochanteric fractures. Level 1, prospective, prognostic study.

  3. Removal torque of nail interlocking screws is related to screw proximity to the fracture and screw breakage.

    Science.gov (United States)

    White, Alexander A; Kubacki, Meghan R; Samona, Jason; Telehowski, Paul; Atkinson, Patrick J

    2016-06-01

    Studies have shown that titanium implants can be challenging to explant due to the material's excellent biocompatibility and resulting osseointegration. Clinically, titanium alloy nail interlocking screws may require removal to dynamize a construct or revise the nail due to nonunion, infection, pain, or periprosthetic fracture. This study was designed to determine what variables influence the removal torque for titanium alloy interlocking screws. An intramedullary nail with four interlocking screws was used to stabilize a 1-cm segmental femoral defect in a canine model for 16 weeks. The animals were observed to be active following a several-day recovery after surgery. In six animals, the femora and implanted nail/screws were first tested to failure in torsion to simulate periprosthetic fracture of an implant after which the screws were then removed. In four additional animals, the screws were removed without mechanical testing. Both intraoperative insertional and extraction torques were recorded for all screws. Mechanical testing to failure broke 10/24 screws. On average, the intact screws required 70% of the insertional torque during removal while broken screws only required 16% of the insertional torque (p torque than the outboard distal screw (p torque was ∼80°. The peak axial load did not significantly correlate with the torque required to remove the screws. On average, the removal torque was lower than at the time of insertion, and less torque was required to remove broken screws and screws remote to the fracture. However, broken screws will require additional time to retrieve the remaining screw fragment. This study suggests that broken screws and screws in prematurely active patients will require less torque to remove. © IMechE 2016.

  4. Greater rate of cephalic screw mobilisation following proximal femoral nailing in hip fractures with a tip-apex distance (TAD) and a calcar referenced TAD greater than 25 mm.

    Science.gov (United States)

    Aicale, Rocco; Maffulli, Nicola

    2018-05-02

    To ascertain whether the tip-apex distance (TAD), calcar referenced TAD (CalTAD), and the sum of both (TADcalTAD) are predictive measurements of mobilisation of the cephalic screw in patients with trochanteric hip fractures. Between 2014 and 2015, 68 patients (mean age 86 years, 45 females, 23 males) with a trochanteric hip fracture underwent intramedullary nailing. The TAD and CalTAD were measured, and for each parameter, we calculated sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). There is evidence of a statistically significant association between a TAD and CalTAD greater than 25 mm and a TADcalTAD greater than 50 mm and mobilisation of the cephalic screw. All measurements have similar sensitivity, but the TAD presents the highest specificity (p TAD and CalTAD less than 25 mm and a TADcalTAD less than 50 mm when using intramedullary fixation.

  5. frequency of ipsilateral femoral neck fractures in patients

    African Journals Online (AJOL)

    Background: Ipsilateral associated femoral neck and shaft fractures are reported to occur in 2.5-6% of all femoral shaft ... nailing of the shaft fracture, which makes treatment of the neck ... chest, spine), while the other had maxillofacial injuries.

  6. Articular cartilage damage with intramedullary lesion (bone bruise) in anterior cruciate ligament rupture

    International Nuclear Information System (INIS)

    Ide, Shuya; Ohdera, Toshihiro; Tokunaga, Masami; Hiroshima, Shiro; Yoshimoto, Eiji

    2002-01-01

    We evaluated the relationship between the intramedullary lesion on MRI and cartilage damage in patients associated with acute anterior cruciate ligament (ACL) rupture. Thirty-two cases documented by MRI and arthroscopy within one month from injury underwent ACL reconstruction using ST-G, and arthroscopy was performed again after surgery. The mean term between reconstruction and postoperative arthroscopy was twelve months. The cartilage damage on arthroscopy was compared with the intramedullary lesion on MRI. Cartilage damage was observed in 9 cases (28.1%) during the initial arthroscopy and in 16 cases (50.0%) during the second arthroscopy. Intramedullary lesion was detected in all 32 cases (total: 73 lesions) on MRI. Intramedullary lesion leading to cartilage damage was common in the geographic-type lateral femoral condyle. There was significant difference between the lateral meniscus tear and the cartilage damage of the lateral compartment. (author)

  7. Sistemas osso-implante ex vivo utilizando haste intramedular polimérica para imobilização de fraturas femorais em bovinos jovens Ex vivo bone-implant systems using polymeric intramedullary nails for fixation of femoral fractures in young calves

    Directory of Open Access Journals (Sweden)

    Odael Spadeto Junior

    2011-02-01

    Full Text Available O desenvolvimento de novos aparatos usando materiais disponíveis e de baixo custo pode ser uma alternativa viável para o tratamento cirúrgico de fraturas em ossos longos de bovinos. O objetivo deste estudo foi avaliar a resistência mecânica de fêmures de bovinos jovens com fratura diafiseal, imobilizados com hastes intramedulares bloqueadas, compostas por diferentes polímeros. Para tanto, testes físicos de compressão e flexão, por meio de uma máquina universal de ensaios foram realizados em quatro grupos distintos de seis fêmures obtidos de bovinos jovens. Em um dos grupos, os ossos foram mantidos íntegros (grupo controle, enquanto que os outros os ossos, foram fraturados e imobilizados com uma haste intramedular bloqueada, composta por polipropileno, poliacetal ou poliamida (uma para cada grupo. Independente do polímero utilizado, nenhuma das hastes estudadas ofereceu aos fêmures fraturados resistência comparável ao osso íntegro, quando consideradas em conjunto as forças de flexão e compressão. A concordância desses achados com resultados in vivo previamente publicados, demonstra que a metodologia utilizada para testes ex vivo pode ser útil na seleção de materiais mais resistentes para confecção de novos modelos.The development of new devices using available and low cost materials may be an useful alternative for the treatment of long bone fractures in large animals. The aim of this study was to evaluate the mechanical strength of young bovine femur with diaphyseal fracture fixed with different polymeric intramedullary nails. Bending and compression tests using a universal machine were carried out in 4 distinct groups of 6 femurs from young calves. In one of the groups bones were intact while in the other three fractured bones were fixed using an intramedullary nail made of polypropylene, polyacetal or polyamide (one for each group. Considering bending and compression tests together, none of the used polymers offered

  8. Author Details

    African Journals Online (AJOL)

    Abstract PDF · Vol 10, No 2 (2013) - Articles Functional Outcomes of the Knee after Retrograde and Antegrade Intramedullary Nailing for Femoral Shaft Fractures Abstract PDF · Vol 11, No 1 (2014) - Articles Treatment and Outcome of Ankle Fractures at the Moi Teaching and Referral Hospital Abstract PDF. ISSN: 2523-0816.

  9. Dispositivo de tração do membro superior para osteossínteses intramedulares bloqueadas anterógradas de fraturas diafisárias de úmero Upper limb traction device for anterograde intramedullary locked nail of humeral shaft fractures

    Directory of Open Access Journals (Sweden)

    Mário Chaves Corrêa

    2010-06-01

    surgically, usually by means of intramedullary locked nail. Some comminuted and/or very deviated shaft fractures can represent a real technical challenge. The fracture table, which allows for the vertical, horizontal and rotational instrumental stabilization of the limb, greatly facilitates reduction and implant placement maneuvers and are widely used by orthopedic surgeons. Humeral shaft fractures are mostly treated nonsurgically. However, some whose indications are well defined in literature require surgical treatment. They can be fixed by plates, or by anterograde or retrograde intramedullary nail. In the humerus, limb fracture reduction and stabilization maneuvers for implantation of intramedullary nails are done manually, usually by 2 assistants. Because they are subject to muscle fatigue, this option may be less efficient. The aim of this paper is to present an external traction device for use in anterograde intramedullary fixation of humerus shaft fractures that allows vertical, horizontal and rotational stabilization of the upper limb similarly to that used in the lower limbs. The device is portable, of simple construction, and can be installed on any operating table equipped with side rails. It was used in the surgical treatment of 29 humeral shaft fractures with anterograde locked intramedullary nail. Our experience was extremely positive. We had no complications related to its use and we believe it to have facilitated the surgical procedures in a remarkable way.

  10. Treatment options for unstable trochanteric fractures: Screw or helical proxima femoral nail.

    Science.gov (United States)

    Bajpai, Jeetendra; Maheshwari, Rajesh; Bajpai, Akansha; Saini, Sumit

    2015-01-01

    To compare treatment outcome of screw proximal femoral nail (PFN) system with that of a helical PFN. The study included 77 patients with closed unstable intertrochanteric fracture classified as AO 31A2&31A3, between June 2008 to August 2011. Inclusion criteria were: all mature skeletons above 50 years of age; closed unstable trochanteric fracture classified as AO 31A2&A3. Exclusion criteria were: immature skeleton, pathological fracture of any cause other than osteoporosis, inability to walk inde- pendently prior to injury. Patients were randomized to 2 treatment groups based on admission sequence. Forty patients were treated with screw PFN and thirty seven were treated with helical PFN. Both groups were similar in respect of time of surgery, blood loss and functional assessment and duration of hospitalization. In screw PFN group 2 patients had superficial wound infection, 1 patient had persistent hip pain and 1 patient had shortening>1 cm buttrochanteric fractures even in Indian patients where the bones are narrow and neck diameter is small. It is an implant of choice for osteoporotic and unstable trochanteric fractures.

  11. Reconstruction of large diaphyseal bone defect by simplified bone transport over nail technique: A 7-case series.

    Science.gov (United States)

    Ferchaud, F; Rony, L; Ducellier, F; Cronier, P; Steiger, V; Hubert, L

    2017-11-01

    Reconstruction of large diaphyseal bone defect is complex and the complications rate is high. This study aimed to assess a simplified technique of segmental bone transport by monorail external fixator over an intramedullary nail.A prospective study included 7 patients: 2 femoral and 5 tibial defects. Mean age was 31years (range: 16-61years). Mean follow-up was 62 months (range: 46-84months). Defects were post-traumatic, with a mean length of 7.2cm (range: 4 to 9.5cm). For 3 patients, reconstruction followed primary failure. In 4 cases, a covering flap was necessary. Transport used an external fixator guided by an intramedullary nail, at a rate of 1mm per day. One pin was implanted on either side of the distraction zone. The external fixator was removed 1 month after bone contact at the docking site. Mean bone transport time was 11 weeks (range: 7-15 weeks). Mean external fixation time was 5.1months (range: 3.5 to 8months). Full weight-bearing was allowed 5.7months (range: 3.5-13months) after initiation of transport. In one patient, a pin had to be repositioned. In 3 patients, the transported segment re-ascended after external fixatorablation, requiring repeat external fixation and resumption of transport. There was just 1 case of superficial pin infection. Reconstruction quality was considered "excellent" on the Paley-Marr criteria in 6 cases. The present technique provided excellent reconstruction quality in 6 of the 7 cases. External fixation time was shorter and resumption of weight-bearing earlier than with other reconstruction techniques, notably including bone autograft, vascularized bone graft or the induced membrane technique. Nailing facilitated control of limb axis and length. The complications rate was 50%, comparable to other techniques. This study raises the question of systematic internal fixation of the docking site, to avoid any mobilization of the transported segment. The bone quality, axial control and rapidity shown by the present technique make

  12. [Trochanteric femoral fractures].

    Science.gov (United States)

    Douša, P; Čech, O; Weissinger, M; Džupa, V

    2013-01-01

    At the present time proximal femoral fractures account for 30% of all fractures referred to hospitals for treatment. Our population is ageing, the proportion of patients with post-menopausal or senile osteoporosis is increasing and therefore the number of proximal femoral fractures requiring urgent treatment is growing too. In the age category of 50 years and older, the incidence of these fractures has increased exponentially. Our department serves as a trauma centre for half of Prague and part of the Central Bohemia Region with a population of 1 150 000. Prague in particular has a high number of elderly citizens. Our experience is based on extensive clinical data obtained from the Register of Proximal Femoral Fractures established in 1997. During 14 years, 4280 patients, 3112 women and 1168 men, were admitted to our department for treatment of proximal femoral fractures. All patients were followed up until healing or development of complications. In the group under study, 82% were patients older than 70 years; 72% of those requiring surgery were in their seventies and eighties. Men were significantly younger than women (pfractures were 2.3-times more frequent in women than in men. In the category under 60 years, men significantly outnumbered women (pfractures were, on the average, eight years older than the patients with intertrochanteric fractures, which is a significant difference (pTrochanteric fractures accounted for 54.7% and femoral neck fractures for 45.3% of all fractures. The inter-annual increase was 5.9%, with more trochanteric than femoral neck fractures. There was a non-significant decrease in intertrochanteric (AO 31-A3) fractures. On the other hand, the number of pertrochanteric (AO 31-A1+2) fractures increased significantly (pfractures were treated with a proximal femoral nail; a short nail was used in 1260 and a long nail in 134 of them. A dynamic hip screw (DHS) was employed to treat 947 fractures. Distinguishing between pertrochanteric (21-A1

  13. [Comparative study of proximal femoral shortening after the third generation of Gamma nail versus proximal femoral nail anti-rotation in treatment of intertrochanteric fracture].

    Science.gov (United States)

    Hou, Yu; Yao, Qi; Zhang, Gen'ai; Ding, Lixiang

    2018-03-01

    To explore the difference of the proximal femoral shortening (PFS) between the third generation of Gamma nail (TGN) and the proximal femoral nail anti-rotation (PFNA) in treating intertrochanteric fracture of femur. The clinical data of 158 patients with intertrochanteric fracture of femur who were treated with TGN internal fixation or PFNA internal fixation between January 2014 and December 2015 were retrospectively analysed. The patients were divided into TGN group (69 cases) and PFNA group (89 cases) according to surgical operation. There was no significant difference in gender, age, bone mineral density, causes of injury, AO/Association for the Study of Internal Fixation (AO/ASIF) classification, accompanied disease, and the time from injury to operation between 2 groups ( P >0.05). The result of fracture reduction was divided into 3 types: positive medial cortex support, neutral position cortex support, and negative medial cortex support according to the method of Chang et al . At 18 months postoperatively, bilateral hip anteroposterior X-ray films were taken to measure horizontal PFS values (marked as X), vertical PFS values (marked as Y), and calculate the total PFS values (marked as Z). The PFS values were divided into 4 grades according to the criteria (≤1.0 mm, 1.0-4.9 mm, 5.0-9.9 mm, and ≥10.0 mm), and the constituent ratio was calculated and compared between 2 groups. The X, Y, and Z values and the collodiaphyseal angles of 2 groups at 18 months postoperatively were compared. The X, Y, and Z values of 2 groups of patients with failed fixation and normal healing within 18 months after operation were recorded and compared. The X, Y, and Z values of 2 groups of the patients with different cortex support types were also compared. There were 34 cases of positive medial cortex support, 30 cases of neutral position cortex support, and 5 cases of negative medial cortex support in TGN group, and there were 45, 33, and 11 cases in PFNA group respectively

  14. Clinical Outcomes after Open Locked Intramedullary Nailing of ...

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... Femoral Shaft Fractures for Adult Patients in a Nigerian Hospital .... posttreatment to assess for progression of healing. .... the most active and mobile members of the society and .... Prehospital management of lower limb.

  15. Intertrochanteric Fracture After Hip Resurfacing Arthroplasty Managed with a Reconstruction Nail

    Directory of Open Access Journals (Sweden)

    Jason Chow

    2013-12-01

    Full Text Available Periprosthetic fractures after hip resurfacings are rare occurrences that can pose a challenge to orthopaedic surgeons. With hip resurfacings becoming more common, the prevalence of these fractures is likely to increase because these patients are usually younger and more active. We report a case of traumatic periprosthetic proximal femur fracture treated with a reconstruction intramedullary nail technique.

  16. Clinical Outcomes after Open Locked Intramedullary Nailing of ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... above who presented within 2 weeks of sustaining closed femoral shaft fractures ... tweak, and build upon the work non-commercially, as long as the author is ... was compressed, and proximal locking screws were then.

  17. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures.

    Science.gov (United States)

    Chen, Fancheng; Huang, Xiaowei; Ya, Yingsun; Ma, Fenfen; Qian, Zhi; Shi, Jifei; Guo, Shuolei; Yu, Baoqing

    2018-01-16

    Proximal tibia fractures are one of the most familiar fractures. Surgical approaches are usually needed for anatomical reduction. However, no single treatment method has been widely established as the standard care. Our present study aims to compare the stress and stability of intramedullary nails (IMN) fixation and double locking plate (DLP) fixation in the treatment of extra-articular proximal tibial fractures. A three-dimensional (3D) finite element model of the extra-articular proximal tibial fracture, whose 2-cm bone gap began 7 cm from the tibial plateau articular surface, was created fixed by different fixation implants. The axial compressive load on an adult knee during single-limb stance was imitated by an axial force of 2500 N with a distribution of 60% to the medial compartment, while the distal end was fixed effectively. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis. The maximal equivalent von Mises stress value of the system in the IMN model was 293.23 MPa, which was higher comparing against that in the DLP fixation model (147.04 MPa). And the mean stress of the model in the IMN model (9.25 MPa) was higher than that of the DLP fixation system in terms of equivalent von Mises stress (EVMS) (P tibial fractures of young patients.

  18. Straight proximal humeral nails are surrounded by more bone stock in comparison to bent nails in an experimental cadaveric study.

    Science.gov (United States)

    Günther, Christian Max; Müller, Peter Ernst; Mutschler, Wolf; Sprecher, Christoph Martin; Milz, Stefan; Braunstein, Volker

    2014-01-01

    In the management of proximal humeral fractures intramedullary implants with bent and straight shape of the proximal part of nail are available. Based on data from previous studies on bone distribution in the humeral head, we hypothesized, that higher densities might exist in the bone stock surrounding straight nails in comparison to their angulated counterparts. With a known positive correlation between bone density and mechanical stability, this could indicate potentially higher rigidity of osteosyntheses done with straight implants. We performed high resolution peripheral quantitative computed tomographies of the potential straight and bent implant bearing regions of 27 cadaveric proximal humeri. The acquired data were analyzed for differences between straight and bent Volumes of Interest as well as intra- and interindividual bone stock distribution. For both straight and bent volumes of interest a considerably declining bone mineral density was found in craniocaudal direction. Mean densities of bent volumes were significantly lower in comparison to their corresponding straight counterparts (p straight shaped implants can be assumed. Since we found a rapid decrease of bone density in cranio-caudal direction, intramedullary implants should be anchored as proximally in the subcortical area as possible to minimize the risk of displacement or cutout. The high correlation between the Volumes of Interest of the corresponding right and left sides could aid in preoperative planning when considering an intra- or extramedullary approach.

  19. Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation.

    Science.gov (United States)

    Knobe, Matthias; Nagel, Philipp; Maier, Klaus-Jürgen; Gradl, Gertraud; Buecking, Benjamin; Sönmez, Tolga T; Modabber, Ali; Prescher, Andreas; Pape, Hans-Christoph

    2016-01-01

    Third-generation cephalomedullary nails currently represent the gold standard in the treatment of unstable trochanteric femur fractures. Recently, an extramedullary rotationally stable screw-anchor system (RoSA) has been developed. It was designed to combine the benefits of screw and blade and to improve stability using a locked trochanteric stabilizing plate (TSP). The purpose of this study was to compare the biomechanical behavior of RoSA/TSP and the proximal femoral nail antirotation (PFNA). Standardized AO/OTA 31A2.2 fractures were induced by an oscillating saw in 10 paired human specimens (n = 20; mean age = 85 years; range: 71-96 years). The fractures were stabilized by either the RoSA/TSP (Koenigsee Implants, Allendorf, Germany) or the PFNA (DePuy Synthes, Zuchwil, Switzerland). Femurs were positioned in 25 degrees of adduction and 10 degrees of posterior flexion and were cyclically loaded with axial sinusoidal pattern at 0.5 Hz, starting at 300 N, with stepwise increase by 300 N every 500 cycles until bone-implant failure occurred. After every load step, the samples were measured visually and radiographically. Femoral head migration was assessed. The stiffness at the load up to the clinically relevant load step of 1800 N (639 ± 378 N/mm (RoSA/TSP) vs. 673 ± 227 N/mm (PFNA); P = 0.542) was comparable, as was the failure load (3000 ± 787 N vs. 3780 ± 874 N; P = 0.059). Up to 1800 N, no femoral head rotation, head migration, or femoral neck shortening were observed either for RoSA/TSP or PFNA. Whereas failure of the PFNA subsumed fractures of the greater trochanter and the lateral wall, a posterior femoral neck fracture with a significantly increased femoral neck shortening (1.7 mm vs. 0 mm; P = 0.012) was the cause of failure with RoSA/TSP. This specific kind of failure was induced by a femoral neck weakening caused by the posterior TSP stabilizing screw. There was no significant difference in biomechanical properties between the RoSA/TSP and the PFNA for

  20. Elastic robust intramedullary nailing for forearm fracture in children

    Directory of Open Access Journals (Sweden)

    Wasem, Jürgen

    2006-01-01

    Full Text Available Background: Forearm fractures are the most common fractures in children (23% of all fractures. Basically there are two treatment options available for diaphyseal forearm fractures in children: closed reduction with cast immobilisation (conservative therapy and the elastic stable intramedullary nailing (ESIN. Treatment decision is influenced by the doctor's estimation of fracture instability. Stable fractures can be treated conservatively whereas instable forearm shaft fractures can be treated according the following three treatment strategies: 1. conservative therapy in an outpatient setting 2. conservative therapy in the operating room in attendance to change to ESIN in case that no stabilisation can be achieved with cast immobilisation 3. immediate treatment with ESIN in the operating room. Objectives: Aim of this Health Technology Assessment (HTA report is to assess and report the published evidence concerning effectiveness and cost-effectiveness of ESIN as a treatment option for diaphyseal forearm fractures in children and to identify future research need. Important parameters for the assessment of effectiveness are objective parameters (axis deviation, losses of motion, and numbers of reductions in case of redislocations and subjective parameters (pain or impairment in quality of life. Furthermore, a health economic evaluation shall be done which refers to the costs of the different therapy strategies. Methods: An extensive, systematic literature search in medical, economic, and HTA literature databases was performed. Relevant data were extracted and synthesised. Results: Three cohort studies and seven case series have been identified. Controlled clinical studies, systematic reviews and/or HTA reports that gave evidence to answer the own study question have not been found. The identified studies partly differed in respect of defined indication for ESIN, study population and treatment strategies. For that reason comparability of results was

  1. Femoral head vitality after intracapsular hip fracture

    International Nuclear Information System (INIS)

    Stroemqvist, B.

    1983-01-01

    Femoral head vitality before, during and at various intervals from the operation was determined by tetracycline labeling and/or 99 sp (m)Tc-MDP scintimetry. In a three-year follow-up, healing prognosis could be determined by scintimetry 3 weeks from operation; deficient femoral head vitality predicting healing complications and retained vitality predicting uncomplicated healing. A comparison between pre- and postoperative scintimetry indicated that further impairment of the femoral head vitality could be caused by the operative procedure, and as tetracycline labeling prior to and after fracture reduction in 370 fractures proved equivalent, it was concluded that the procedure of osteosynthesis probably was responsible for capsular vessel injury, using a four-flanged nail. The four-flanged nail was compared with a low-traumatic method of osteosynthesis, two hook-pins, in a prospective randomized 14 month study, and the postoperative femoral head vitality was significantly better in the hook-pin group. This was also clearly demonstrated in a one-year follow-up for the fractures included in the study. Parallel to these investigations, the reliability of the methods of vitality determination was found satisfactory in methodologic studies. For clinical purpose, primary atraumatic osteosynthesis, postoperative prognostic scintimetry and early secondary arthroplasty when indicated, was concluded to be the appropriate approach to femoral neck fracture treatment. (Author)

  2. Single stage management of Gustilo type III A/B tibia fractures: Fixed with nail & covered with fasciocutaneous flap

    Directory of Open Access Journals (Sweden)

    G.I. Nambi

    2017-04-01

    Conclusion: Multidisciplinary management of severe lower limb trauma is important and provides good outcomes. Intramedullary nailing and immediate flap fixation can achieve early bone union and good soft tissue coverage, leading to good outcomes in patient with Grade III A & B tibia fractures.

  3. CROSS-SECTIONAL STUDY ON DIFFERENT ENTRY POINTS FOR ANTEROGRADE FEMORAL INTRAMEDULLARY OSTEOSYNTHESIS

    Science.gov (United States)

    Kanas, Michel; Wajnsztejn, Andre; Roucourt, Danilo; Fiorentino, Eduardo; Fernandes, Hélio Jorge Alvachian; dos Reis, Fernando Baldy

    2015-01-01

    Objective: To analyze the degree of knowledge among professionals who treat fractures using the recommended technique, with regard to correlating the nail with the entry point that is considered appropriate. Methods: A questionnaire that presented five types of nail and simulated a transverse diaphyseal fracture of the femur was developed. Results: Responses regarding the entry points corresponding to choosing the type of nail were obtained from 370 orthopedists who were participating in the 41st Brazilian Congress of Orthopedics and Traumatology. It was observed that only 20% correctly identified the entry point and that there was no difference between the professionals within the specialty of Traumatology and the others. Conclusion: It was concluded that the majority of the physicians attending the congress were unaware of the entry points. PMID:27027047

  4. Assessment of the geometry of proximal femur for short cephalomedullary nail placement: An observational study in dry femora and living subjects

    Directory of Open Access Journals (Sweden)

    Devendra Pathrot

    2016-01-01

    Full Text Available Background: Intramedullary devices have increasingly become popular and are widely used for fixation of unstable intertrochanteric and subtrochanteric fractures as well. These implants have been designed taking into consideration the anthropometry of the western population whose anthropometry varies from those of other ethnic groups. This study was carried out to assess the geometry of proximal femur for the placement of short cephalomedullary nails in our subset of patients and suggest suitable design modifications based on these parameters. Materials and Methods: The study was conducted in the following three groups: (1 Anthropometric study of 101 adult human dry femora, (2 radiographs of the same femora, and (3 radiographs of the contralateral uninjured limb of 102 patients with intertrochanteric or subtrochanteric fractures. In Group 1, standard anthropometric techniques were used to measure neck shaft angle (NSA, minimal neck width (NW, trochanteric offset, and distance from the tip of greater trochanter (GT to the lower border of lesser trochanter on the femoral shaft axis (distance X. In Group 2 and 3, the NSA, minimal NW, NW at 130° and 135°, trochanteric shaft angle (TSA, trochanteric offset, distance X, distance between the tip of GT and the point where the neck axis crosses the line joining the tip of the GT to the lower border of the lesser trochanter on the femoral shaft axis (distance Y, and canal width at 10, 15, and 20 cm from tip of GT were measured on standard radiographs. The values obtained in these three groups were pooled to obtain mean values. Various parameters of commonly used short cephalomedullary nails available for fixation of pertrochanteric fractures were obtained. These were compared to the results obtained to suggest suitable modifications in the nail designs for our subset of patients. Results: The mean parameters observed were as follows: NSA 128.07° ± 4.97 (range 107°–141°, minimum NW 29.0 ± 2.8 mm

  5. Breakage of a Third Generation Gamma Nail: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Takashi Iwakura

    2013-01-01

    Full Text Available The use of intramedullary nails to treat trochanteric fractures of the femur has increased with the increasing size of the elderly population. The third generation Gamma nail is currently one of the most popular devices for the treatment of trochanteric fractures. Nail breakage is a rare complication, possibly resulting from fatigue fracture of the implant. We present the first reported case of breakage of a third generation Gamma nail that was not used to treat a pathological fracture. An 83-year-old woman with an unstable trochanteric fracture of the femur was treated using a third generation Gamma nail. She was referred to our hospital 14 months postoperatively with nail breakage at the opening for the lag screw. The breakage was secondary to nonunion, which was thought to be mainly due to insufficient reduction of the fracture. The broken nail was removed, and the patient underwent cemented bipolar hemiarthroplasty. At followup 18 months later, she was mobile with a walker and asymptomatic with no complications. This case shows that inadequate operation such as insufficient reduction of the trochanteric fracture may result in nonunion and implant breakage, even when using a high-strength, well-designed implant.

  6. Study of Ender’s Nailing in Shaft Femur Fractures of Older Children

    Directory of Open Access Journals (Sweden)

    Ladani HG

    2014-12-01

    Full Text Available Background: Fractures in shaft femur in children are relatively common. Various methods of treating these fractures starting from non operative to methods like closed intramedullary nailing are at our disposal. Traditionally non operative methods are acceptable and find wide acceptance even today in very young children. However in older children certain problems are encountered like failure to control angulation and shortening, prolonged immobilization which causes very much discomfort & the overgrowth phenomenon. In view of above difficulties, closed intramedullary nailing was attempted in older children and adolescents. I have tried to study 23 cases of shaft femur fractures in older children treated by Ender’s nails. Methodology: 22 pts., out of which one having bilateral # shaft femur (total 23 #s with age ranging from 7 to 16 yrs. were studied. 3 pts. having polio limbs studied separately. Fracture was in upper third shaft femur in 5 pts., middle third in 13 pts., lower third in 3pts. & involving more than one region in 2 pts. Fracture was transverse in 6 pts., spiral in 3 pts., oblique in 12 pts.& comminuted in 2 pts.. Results: Average union time was 10 weeks except in polio pts. where it was delayed. No nonunion, no infection. Excellent hip & knee movements in almost all pts. Out of 20 pts. ( except polio pts. limb length was equal in 17 pts., one pt. was having 1 cm. lengthening & 2 pts. were having shortening ( 1cm. & 2 cm.. Conclusion: Results of this study strongly favor the use of Ender’s nailing in shaft femur fractures in older children. Second surgery of implant removal is mandatory. Closed reduction can usually be achieved if surgery is performed earlier.

  7. Treatment of distal tibial fractures: plate versus nail: a retrospective outcome analysis of matched pairs of patients.

    NARCIS (Netherlands)

    Janssen, K.W.; Biert, J.; Kampen, A. van

    2007-01-01

    A study of 24 patients who sustained an extra-articular fracture of the distal third of the tibial shaft was performed to determine the effect of the type of treatment, open reduction and internal fixation (ORIF) or closed reduction and intramedullary (IM) nailing, on the occurrence of malalignment.

  8. A COMPARATIVE STUDY OF PROXIMAL FEMUR LOCKING COMPRESSION PLATE VERSUS PROXIMAL FEMORAL NAILING IN THE MANAGEMENT OF COMMINUTED TROCHANTERIC AND SUBTROCHANTERIC FRACTURE

    Directory of Open Access Journals (Sweden)

    Satish Koti

    2016-11-01

    Full Text Available BACKGROUND Fractures of proximal femur and hip are relatively common injuries in elderly individuals constituting 11.6% of total fractures. The latest implant for management of intertrochanteric fracture is Proximal Femoral Locking Compression Plate (PF-LCP. In this study, we compare the clinical outcome of fractures treated by proximal femoral nail with that of proximal femur locking compression plate. MATERIALS AND METHODS The present study consists of 24 elderly patients of peritrochanteric factures of femur satisfying the inclusion criteria who were treated with PF-LCP or PFN in Department of Orthopaedics, S.V.R.R.G.G.H, Tirupati, during a period between December 2013 to October 2015. RESULTS 24 cases were treated with PF-LCP or PFN in a randomised pattern who satisfied inclusion criteria. Intraoperative complication were found to be more with PF-LCP in contrast to PFN. Postoperative rehabilitation was easier with PFN though not statistically significant functional and anatomical outcomes were found to be better with PFN. CONCLUSION Both PFN and PF-LCP have good effectiveness in the treatment of intertrochanteric fractures with the lateral unsubstantial femoral wall in the elderly patients. Each has its own advantages and disadvantages. Further studies with large number of patients and long-term follow up is needed to determine the optimal implant for the internal fixation of comminuted pertrochanteric femoral fractures.

  9. Sliding hip screw versus the Targon PFT nail for trochanteric hip fractures: a randomised trial of 400 patients.

    Science.gov (United States)

    Parker, M J; Cawley, S

    2017-09-01

    To compare the outcomes for trochanteric fractures treated with a sliding hip screw (SHS) or a cephalomedullary nail. A total of 400 patients with a trochanteric hip fracture were randomised to receive a SHS or a cephalomedullary nail (Targon PFT). All surviving patients were followed up to one year from injury. Functional outcome was assessed by a research nurse blinded to the implant used. Recovery of mobility, as assessed by a mobility scale, was superior for those treated with the intramedullary nail compared with the SHS at eight weeks, three and nine months (p-values between 0.01 and 0.04), the difference at six and 12 months was not statistically significant (p = 0.15 and p = 0.18 respectively). The mean difference was around 0.4 points (0.3 to 0.5) on a nine point scale. Surgical time for the nail was four minutes less than that for the SHS (p Fracture healing complications were similar for the two groups. There were no statistically significant differences between implants for any other recorded outcomes including the need for post-operative blood transfusion, wound healing complications, general medical complications, hospital stay or mortality. This study confirms the findings of a previous study that both methods of treatment produce similar results, although intramedullary fixation does result in marginally improved regain of mobility in comparison with the SHS. Cite this article: Bone Joint J 2017;99-B:1210-15. ©2017 The British Editorial Society of Bone & Joint Surgery.

  10. Intramedullary nails versus sliding hip screws for AO/OTA 31-A2 trochanteric fractures in adults: A meta-analysis.

    Science.gov (United States)

    Zhu, Qianzheng; Xu, Xiaodong; Yang, Xi; Chen, Xingzuo; Wang, Liqiang; Liu, Chenggang; Lin, Peng

    2017-07-01

    The optimum treatment with intramedullary nails (IMN) or sliding hip screws (SHS) for type 31-A2 trochanteric fractures remains controversial. Therefore, we performed a meta-analysis of randomized controlled trials (RCTs) to compare IMN with SHS in AO/OTA 31-A2 trochanteric fractures. Databases including PubMed, Cochrane, and Embase were searched to identify RCTs published before December 2016, which compared IMN with SHS for intraoperative and postoperative outcomes in AO/OTA 31-A2 trochanteric fractures. A total of 909 patients from six RCTs were subjected to the meta-analysis. The results showed that the IMN group was associated with less operative blood loss, leg shortening, wound infections, length of hospital stay, and days to mobilization with walking aids and also yielded a higher Parker score as compared to the SHS group. No significant difference was seen in the other parameters including operative details, fracture fixation complications, postoperative complications, and 1 year mortality. IMN fixation was found to be the superior treatment of choice for 31-A2 trochanteric fractures as compared with SHS fixation in our meta-analysis. The adverse effects appeared comparable between the two groups. However, due to the variations in the included studies, more large-sample, measures-unified, and high-quality RCTs are needed to validate these conclusions. Copyright © 2017. Published by Elsevier Ltd.

  11. Extramedullary versus intramedullary tibial cutting guides in megaprosthetic total knee replacement

    Directory of Open Access Journals (Sweden)

    Karade Vikas

    2012-10-01

    Full Text Available Abstract Background In a standard total knee replacement, tibial component alignment is a key factor for the long term success of the surgery. The purpose of this study is to compare the accuracy of extramedullary and intramedullary tibial cutting guides used in indigenous and imported implants respectively, in positioning of the tibial components in megaprosthetic knee replacements. Methods A comparative study of the accuracy of extramedullary and intramedullary tibial cutting guides was carried out in 92 megaprosthetic knee replacements for distal femoral tumors. For the proximal tibia cut for tibial component placement, an extramedullary guide was used in 65 patients and an intramedullary guide was used in 27 patients. Tibial component alignment angles were measured in postoperative X-rays with the help of CAD software. Results There was more varus placement in coronal plane with extramedullary cutting guide (−1.18 +/− 2.4 degrees than the intramedullary guide (−0.34 +/− 2.31 degrees but this did not reach statistical significance. The goal of 90 +/− 2 degrees alignment of tibial component was achieved in 54% of patients in the extramedullary group versus 67% in the intramedullary group. In terms of sagittal plane alignment, extramedullary guide showed less accurate results (2.09 +/− 2.4 degrees than intramedullary guide (0.50 +/− 3.80 degrees for tibial component alignment, though 78% of patients were aligned within the goal of 0–5 degrees of tibial slope angle in extramedullary group versus 63% in intramedullary group. The mean error in the measurements due to rotation of the knee during taking the X-rays was less than 0.1 degrees and distribution of the X-rays with the rotation of knee was similar in both the groups. Conclusions Overall, in megaprosthetic knee replacement intramedullary guides gave more accurate results in sagittal plane and exhibited similar variability as of extramedullary guides in coronal plane.

  12. [Treatment of postoperative nonunion of fracture of lower limb with bone grafting by intervertebral disc endoscope].

    Science.gov (United States)

    Zhang, Jianlin; Tan, Yu'e; Ye, Jun; Han, Fangmin

    2012-02-01

    To explore the effectiveness of bone grafting by intervertebral disc endoscope for postoperative nonunion of fracture of lower limb. Between August 2004 and August 2008, 40 patients (23 males and 17 females) with postoperative nonunion of femoral and tibial fracture, aged 20-63 years (mean, 41.5 years) were treated. Nonunion of fracture occurred at 10-16 months after internal fixation. During the first operation, the internal fixation included interlocking intramedullary nailing of femoral fracture in 12 cases and plate in 16 cases, and interlocking intramedullary nailing of tibial fractures in 9 cases and plate in 3 cases. The X-ray films showed hypertrophic nonunion in 24 cases, common nonunion in 3 cases, and atrophic nonunion in 13 cases. The average operation time was 61 minutes (range, 40-80 minutes), and the blood loss was 80-130 mL (mean, 100 mL). The hospitalization time were 6-11 days (mean, 8.1 days). Incisions healed by first intention in all patients with no complication of infection or neurovascular injury. Forty patients were followed up 10-16 months (mean, 12.3 months). The X-ray films showed that all patients achieved healing of fracture after 4-10 months (mean, 6.8 months). No pain, disfunction, or internal fixation failure occurred. Bone grafting by intervertebral disc endoscope is an effective method for treating postoperative nonunion of femoral and tibial fracture.

  13. Subtrochanteric hip fractures treated with cerclage cables and long cephalomedullary nails: a review of 17 consecutive cases over 2 years.

    LENUS (Irish Health Repository)

    Kennedy, Muiris T

    2011-11-01

    The conflict between the anatomist and biologist surgeons is exemplified by the debate about subtrochanteric hip fractures. Closed intramedullary nailing is biologically friendly but may result in prolonged procedures and malunion. By contrast, accurate anatomical open reduction may disturb the biological composition of the fracture environment.

  14. Early experience with titanium elastic nails in a trauma unit.

    LENUS (Irish Health Repository)

    Shah, M H

    2012-02-03

    The Titanium Elastic Nail (TEN) offers a number of potential advantages over traditional ways of treating long bone fractures particularly in the paediatric population. These advantages include earlier mobilisation and shorter hospital stay and less risk of loss of fracture position. These advantages are most apparent and significant when treating femoral fractures in children where the length of hospital stay is reduced from several weeks to a typical period of 5 to 8 days. We have reviewed our early experience of using these implants over the past 2 years. Patients were assessed clinically and radiologically. 13 patients were treated using the TEN during this period. There were 2 femoral fractures, 4 humeral fractures, 1 tibial and 6 forearm fractures treated using the Titanium Elastic Nail. All fractures united during the study period. However 1 humeral fracture required a secondary bone grafting and plating for delayed union and 1 fracture lost position during follow-up. Insertion point pain was a problem in 4 patients but this resolved after nail removal in all. There was 1 superficial wound infection which resolved with antibiotics and 1 superficial wound infection of an open fracture wound which resolved following nail removal and antibiotics. There were no cases of deep infection. There were no limb length discrepancy or rotational or angular malalignment problems. Biomechanical principles and technical aspects of this type of fixation are discussed.

  15. Closed External Fixation for Failing or Failed Femoral Shaft Plating in a Developing Country.

    Science.gov (United States)

    Aliakbar, Adil; Witwit, Ibrahim; Al-Algawy, Alaa A Hussein

    2017-08-01

    Femoral shaft fractures are one of the common injuries that is treated by open reduction, with internal fixation by plate and screws or intramedullary nailing, which can achieve a high union rate. To evaluate the outcome of using closed external fixation to augment a failing plate; with signs of screw loosening and increasing bone/plate gap; a failed plate; broken plate; screws completely out of bone with redisplacement of fracture. A retrospective study on 18 patients, aged between 17-42 years, who presented between 6-18 weeks after initial surgical fixation, with pain, difficulty in limb function, deformity and abnormal movement at fracture site, was done. X-Rays showed plating failure with acceptable amount of callus, which unfortunately had refractured. Cases associated with infection and no radiological evidence of callus formation were excluded from this study. Closed reduction was done by manipulation, then fracture fixation by AO external fixator. The patients were encouraged for full weight bearing as early as possible with dynamization later on. Of the 18 patients who underwent external fixation after close reduction, 15 cases showed bone healing in a period between 11-18 weeks (mean of 14.27 weeks) with good alignment (Radiologically). Removal of external fixator was done followed by physical therapy thereafter. Closed external fixation for treatment of failing or failed femoral plating, achieves good success rate and has less complications, is a short time procedure, especially in a hospital with limited resources.

  16. Treatment of humeral shaft fractures using antegrade nailing: functional outcome in the shoulder.

    Science.gov (United States)

    Patino, Juan Martin

    2015-08-01

    The purpose of this study was to evaluate shoulder outcomes and function after humeral shaft fractures treated with antegrade nailing. Thirty patients with acute humeral shaft fractures who underwent antegrade locked intramedullary nailing were retrospectively studied. Range of motion (ROM) of the affected shoulder was evaluated, comparing it with the nonaffected shoulder, radiologic position of the nails, complications, and need for a second surgery. The study enrolled 20 men and 10 women (average age, 41.9 years). The average follow-up was 35.8 months. The average shoulder elevation averaged 157°, internal rotation was variable (reaching the sacroiliac joint to T7), and external rotation averaged 75°. Elbow flexion-extension ROM averaged 133° (115°-145°). According to the Rodriguez-Merchan criteria, 12 patients achieved excellent results (40%), 7 good (20%), and 6 fair (23.3%); poor results were found in 5 cases (16.6%). Twelve patients achieved full mobility of the shoulder, whereas 18 had some loss of motion, with significant differences between the affected and nonaffected shoulders (P = .001). Decreased shoulder ROM is common after antegrade nailing of humeral shaft fractures. Avoidance of nail impingement can improve final outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Slow Recovery of Weight Bearing After Stabilization of Long-Bone Fractures Using Elastic Stable Intramedullary Nails in Children.

    Science.gov (United States)

    Lardelli, Patrizia; Frech-Dörfler, Martina; Holland-Cunz, Stefan; Mayr, Johannes

    2016-03-01

    Stabilization of diaphyseal long-bone fractures using elastic stable intramedullary nails (ESIN) in children promises early mobilization and rapid resumption of full weight bearing. We evaluated the duration of postoperative functional rehabilitation after ESIN, measured by the time from stabilization until first partial weight bearing, full weight bearing, and resumption of school sports. Fifty children with unstable, displaced fractures of the femur or lower leg treated with ESIN between 2002 and 2012 were included in this retrospective analysis. We classified fractures according to the pediatric comprehensive classification of fractures (PCCF). Thirty-five children sustained a femur fracture, and 15 children had a fracture of the lower leg or tibia. The surgeons in charge applied an additional plaster cast in 7 of 15 children who suffered a lower leg fracture. The postoperative time interval until full weight bearing in the group of children who had suffered transverse or short oblique femur fractures was significantly shorter (median: 4.4 weeks; range: 0.1-9.1 weeks) than that in the group who had sustained more complex fracture patterns (median: 6.8 weeks; range: 2.9-13.9 weeks; P = 0.04). Similarly, transverse and short oblique lower leg and tibia fractures required less time until full weight bearing (median: 4.1 weeks; range 2.7-6.0 weeks) than complex lower leg fractures (median: 6.1 weeks; range: 1.3-12.9 weeks; P = 0.04). ESIN proved fairly effective in restoring full weight bearing in transverse or short oblique fractures of the lower extremities but was less effective in complex fractures.

  18. SUPRACONDYLAR FRACTURE FEMUR T REATED WITH INTRAMEDULLARY NAIL : A PROSPECTIVE STUDY

    OpenAIRE

    Venkateswara Rao; Chaitanya; Anvesh

    2015-01-01

    BACKGROUND: Supracondylar fractures are one of the commonest fractures encountered in high velocity trauma which are associated with high morbidity and mortality . 1 Isolated fracture can itself lead to complications such as ARDS and pulmonary embo lism 1 . This necessitates early stabilization of fractures. Internal fixation is the choice of treatment in supracondylar fractures (AO type – A) . 2 Retrograde supracondylar nail has shown to giv...

  19. Causes and treatments of lag screw's cut out after intramedullary nailing osteosinthesis for trochanteric fractures.

    Science.gov (United States)

    Gazzotti, Gabriele; Matino, Giovanni; Tsatsis, Christos; Sacchetti, GianLuigi; Baudi, Paolo; Catani, Fabio

    2014-08-20

    Background. Superior cut-out of a lag screw remains a serious complication in the treatment of trochanteric or subtrochanteric fractures and it is related to many factors: the type of fracture, osteoporosis and the stability of fracture reduction. Little is known about the outcome after revision surgery for complications of the gamma nail. We assessed the outcome in patients who had revision surgery because of lag screw's cut out after gamma nailing for a trochanteric fracture.Material and Method. We present a study of 20 consecutive patients who underwent treatment after 20 cut-out of the lag screw fixation of a trochanteric fracture with Gamma Locking Nail from September 2004 to November 2010. In 16 patients hip prothesis was performed, in 1 the removal of the implant and in 3 the reosteosynthesis. We reviewed 13 patients: 10 total hip arthroplasty, 2 endoprothesis and 1 reosteosynthesis of nail and lag screw (mean follow up: 26 months, mean age: 73 years old), 7 patients died. Patients were reviewed retrospectively by an independent observer. Clinical evaluation was performed, Oxford score and Harris Hip score were measured. X-Ray examination was performed after a minimum of 12 months of follow up.Results. Mean Harris Hip Score mean was 67 and mean Oxford score was 32 in hip prothesis group (12 patients). We had several complications, Implant-related complications were: 2 ipometria > 2cm, 2 recurrent hip arthroplasty dislocations (1 reoperated), 4 persistent thigh pain. In only 4 patients none complications were observed. Another patient,  who had been subjected to reosteosinthesis, obtained better results (HHS:95, Oxford score:45) but with a 2 cm ipometria and occasional pain in the thigh.Conclusion. Cut out after gamma nail is consequent to biological or mechanical causes. Treatment of this complication is hip prosthesis (parzial or total hip arthroplasty), reosteosynthesis of the lag screw and/or the nail and the removal of the implant. Conversion to total

  20. Breakage of cephalomedullary nailing in operative treatment of trochanteric and subtrochanteric femoral fractures.

    Science.gov (United States)

    von Rüden, Christian; Hungerer, Sven; Augat, Peter; Trapp, Oliver; Bühren, Volker; Hierholzer, Christian

    2015-02-01

    Mechanical breakage of cephalomedullary nail osteosynthesis is a rare complication attributed to delayed fracture union or nonunion. This study presents a series of cases of breakage and secondary lag screw dislocation after cephalomedullary nailing. The aim of this study was to identify factors that contribute to cephalomedullary nail breakage. In a retrospective case series review between 02/2005 and 12/2013, we analyzed 453 patients with trochanteric and subtrochanteric fracture who had been treated by cephalomedullary nailing. Fractures were classified according to AO/OTA classification. 13 patients with cephalomedullary nail breakage were included (failure rate 2.9 %). Seven patients were women, and six men with a mean age of 72 years (range 35-94). Implant breakage occurred 6 months postoperatively (range 1-19 months). In ten cases, breakage was secondary to delayed or nonunion, which was thought to be mainly due to insufficient reduction of the fracture, and in two cases due to loss of the lag screw because of missing set screw. In one case, breakage was apparent during elective metal removal following complete fracture healing. Short-term outcome was evaluated 6 months after operative revision using Harris hip score in 11 out of 13 patients showing a mean score of 84 %. Complete radiological fracture healing has been found in 11 patients available for follow-up within 6 months after revision surgery. Breakage of cephalomedullary nail osteosynthesis of trochanteric fractures is a severe complication. The results of our study demonstrate that revision surgery provides good clinical and radiological short-term results. Predominately, failures of trochanteric fractures are related to lack of surgeon performance. Therefore, application of the implant requires accurate preoperative planning, advanced surgical experience to evaluate the patient and the fracture classification, and precise surgical technique including attention to detail and anatomical

  1. Haste bloqueada "Faculdade de Medicina de Ribeirão Preto": experiência clínica no tratamento das fraturas femorais Ribeirão Preto school of medicine locking nail: clinical experience in the femoral fractures treatment

    Directory of Open Access Journals (Sweden)

    Fernando Mendes Paschoal

    2000-12-01

    Full Text Available Uma série de 103 casos de fraturas diafisárias complexas do fêmur foram tratadas com a haste intramedular bloqueada FMRP, no período de maio de 1987 a dezembro 1995. Das 103 fraturas, 67 eram cominutivas, 12 bifocais (segmentar, 4 espirais, 13 proximais e 21 distais, instáveis, rotacionalmente, da diáfise femoral. Do total dos casos, constatou-se 97 bloqueios estáticos e 6 dinâmicos. Dessas 97 estáticas, 7 foram dinamizadas durante a evolução. Clínica e radiográficamente a consolidação ocorreu em 97,09% dos casos, com média de 16,72 semanas e em 3 casos não houve consolidação. Houve 4 casos de infecção suspeita e 3 estabelecidas que foram debeladas e evoluíram para consolidação. Houve 81 casos de encurtamentos que variaram entre 0,5 a 4 cm com média de 1 cm. O encurtamento menor ou igual a 2 cm ocorreu em 73 casos. Desvio de alinhamento em qualquer plano acima de 10 º e igual a 15º foi observado em 8 pacientes. Houve 10 casos de deformidades rotacionais, porém nenhum caso acima de 10º. A incidência de infecção foi baixa e a de consolidação alta. A estabilização dessas fraturas complexas permitiu imediata mobilização do paciente, reabilitação precoce do membro e diminuição da permanência hospitalar, excetuando os politraumatizados. A haste FMRP permitiu o tratamento dessas fraturas sem o uso de intensificador de imagens e de fresas flexíveis com baixo custo operacional. Os resultados foram semelhantes aos obtidos com as hastes intramedulares bloqueadas que necessitam de aparelhagem técnica mais sofisticada, porém com vantagens para o paciente e a equipe cirúrgica.A series of 103 cases of complex femoral fracture were treated with FMRP (Faculdade de Medicina de Ribeirão Preto nail. These fractures were treated from May 1987 until December 1995. From the 103 fractures, 67 were cominutive, 12 bifocal (segmental, 4 spiral, 13 proximal e 21 distal and unstable rotationaly. From the total of cases, 97

  2. Metallographic examination of a failed Jewett nail-plate from a human femur

    International Nuclear Information System (INIS)

    Gray, R.J.; Zirkel, L.G. Jr.

    1976-01-01

    A type 316L wrought stainless steel Jewett nail-plate is one of several implant designs for bridging fractures in the proximal end of the femur. A soldier received a high velocity projectile in the trochanteric region of the femur. He was treated for a subtrochanteric fracture and greater trochanteric bone loss. After 9 months, hip varus angulation was progressively increasing. A Jewett nail-plate was inserted after valgus osteotomy and bone grafting of the unhealed fracture. The nail-plate fractured three weeks after surgery. Optical and scanning electron microscopy related the origin of failure to an impactor failure and subsequent microscopic scoring of the nail-plate during insertion into the abnormally hard femoral head. Photomicrographs showing the implant failure and evidences of corrosion after the short time in the body are presented. 12 figs

  3. Femoral neck-shaft angle in extra-capsular proximal femoral fracture fixation; does it make a TAD of difference?

    Science.gov (United States)

    Walton, N P; Wynn-Jones, H; Ward, M S; Wimhurst, J A

    2005-11-01

    The effect of femoral neck-shaft angle and implant type on the accuracy of lag screw placement in extra-capsular proximal femoral fracture fixation was investigated. Radiographs of all extra-capsular proximal femoral fractures seen in one unit over 18 months were reviewed. Of 399 cases, 307 (237 female, 70 male) were included in the study as they had no contra-lateral proximal femoral metal work. Femoral neck-shaft angle (NSA) of the uninjured hip and magnification adjusted tip-apex distance (TAD) of femoral head lag screw were measured. Type of fixation implant was 135 degrees classic hip screw (CHS) (n=144) or 130 degrees intra-medullary hip screw (IMHS) (n=163). Mean contra-lateral NSA was 130.2 degrees (112.9--148 degrees ) and 64 patients (58 female, 6 male) had a NSA TAD was 18.7 mm (5.8--43.8mm) and 88.9% of cases had a TAD of less than 25 mm. TAD values were significantly greater using an IMHS if NSA was 125 degrees (p=0.028). This was not the case with the CHS. The use of the 130 degrees -IMHS in patients with a NSA 125 degrees and caution is advocated when using this device in such cases.

  4. Bactericidal properties of silver films on intramedullary implants

    Science.gov (United States)

    Gallagher, C.; Walker, C.; Cortes, E.; Hettinger, Jeffrey; Krchnavek, R.; Caputo, G. A.; Ostrum, R.

    2011-03-01

    We report on investigations of silver films on titanium and stainless steel substrates as anti-bacterial coatings for intramedullary nails used in orthopedic trauma. Silver films are deposited using a magnetron sputtering technique from a single elemental target. The deposition parameter (energy, pressure, and temperature) dependence of the silver film microstructure and adhesion will be presented. Preliminary measurements of the effectiveness of the silver films as a bactericide on S. aureus bacteria demonstrate that the films are effective destroying the bacteria. The process of this investigation will be presented. Preliminary transmission electron microscopy measurements will also presented which image healthy and damaged bacteria helping to identify the fundamental mechanism leading to the effectiveness of silver as an anti-bacterial coating. We acknowledge the support of Rowan University, College of Liberal Arts and Sciences.

  5. Avascular necrosis associated with nailing of femoral neck fracture

    International Nuclear Information System (INIS)

    Stroemqvist, B.; Hansson, L.I.

    1983-01-01

    Two patients with femoral neck fractures, one displaced and one undisplaced, are presented. Preoperative intravital staining with tetracycline and Tc-MDP scintimetry both showed intact femoral head circulation while Tc-MDP-scintimetry 1 week after operation showed pronounced circulatory deficiency. SR 85 -scintimetry performed at the same time was inconclusive. Segmental collapse was observed radiographically, 8 and 12 months postoperatively. The major vascular injury resulting in avascularity most probably occured during the procedure of osteosynthesis, and Tc-MDP-scintimetry was found suitable for early postoperative recognition of avascular necrosis in both fractures. (author)

  6. Avascular necrosis associated with nailing of femoral neck fracture

    Energy Technology Data Exchange (ETDEWEB)

    Stroemqvist, B; Hansson, L I [Department of Orthopaedic Surgery, University Hospital in Lund, Sweden

    1983-01-01

    Two patients with femoral neck fractures, one displaced and one undisplaced, are presented. Preoperative intravital staining with tetracycline and Tc-MDP scintimetry both showed intact femoral head circulation while Tc-MDP-scintimetry 1 week after operation showed pronounced circulatory deficiency. Sr/sup 85/-scintimetry performed at the same time was inconclusive. Segmental collapse was observed radiographically, 8 and 12 months postoperatively. The major vascular injury resulting in avascularity most probably occured during the procedure of osteosynthesis, and Tc-MDP-scintimetry was found suitable for early postoperative recognition of avascular necrosis in both fractures.

  7. Femoral fractures : indications an[d] biomechanics of external fixation

    NARCIS (Netherlands)

    A.H. Broekhuizen (Tom); B. van Linge

    1988-01-01

    textabstractInternal fixation can be carried out in various ways. For femoral shaft fractures, an (interlocking) nail is becoming increasingly popular, instead of open realignment of the fracture. External fixation, which has become a generally accepted method of treating fractures of the lower

  8. Can a semi-automated surface matching and principal axis-based algorithm accurately quantify femoral shaft fracture alignment in six degrees of freedom?

    Science.gov (United States)

    Crookshank, Meghan C; Beek, Maarten; Singh, Devin; Schemitsch, Emil H; Whyne, Cari M

    2013-07-01

    Accurate alignment of femoral shaft fractures treated with intramedullary nailing remains a challenge for orthopaedic surgeons. The aim of this study is to develop and validate a cone-beam CT-based, semi-automated algorithm to quantify the malalignment in six degrees of freedom (6DOF) using a surface matching and principal axes-based approach. Complex comminuted diaphyseal fractures were created in nine cadaveric femora and cone-beam CT images were acquired (27 cases total). Scans were cropped and segmented using intensity-based thresholding, producing superior, inferior and comminution volumes. Cylinders were fit to estimate the long axes of the superior and inferior fragments. The angle and distance between the two cylindrical axes were calculated to determine flexion/extension and varus/valgus angulation and medial/lateral and anterior/posterior translations, respectively. Both surfaces were unwrapped about the cylindrical axes. Three methods of matching the unwrapped surface for determination of periaxial rotation were compared based on minimizing the distance between features. The calculated corrections were compared to the input malalignment conditions. All 6DOF were calculated to within current clinical tolerances for all but two cases. This algorithm yielded accurate quantification of malalignment of femoral shaft fractures for fracture gaps up to 60 mm, based on a single CBCT image of the fractured limb. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.

  9. External fixation for closed pediatric femoral shaft fractures: where are we now?

    Science.gov (United States)

    Kong, Heather; Sabharwal, Sanjeev

    2014-12-01

    Recent advances in external fixation technique and pin design have sought to minimize complications such as pin site infection and premature removal of the external fixator. Although newer forms of internal fixation have gained popularity, external fixation may still have a role in managing pediatric femoral shaft fractures. We sought to assess the time to healing, limb alignment, and complications observed in a cohort of pediatric patients with closed femoral shaft fractures who were treated with external fixation. Over a 15-year period, one surgeon treated 289 pediatric patients with femur fractures, 31 (11%) of whom received an external fixator. The general indications for use of an external fixator during the period in question included length-unstable fractures, metadiaphyseal location, refracture, and pathologic fracture. Six patients (19%) had inadequate followup data and four patients (13%) were treated with a combination of flexible intramedullary nails and external fixation, leaving 21 patients for analysis. Mean age at injury was 10 years (range, 6-15 years) and followup averaged 22 months (range, 5-45 months) after removal of the fixator. Radiographs were examined for alignment and limb length discrepancy. Complications were recorded from a chart review. Mean time in the fixator was 17 weeks (range, 9-24 weeks). One patient sustained a refracture and one patient with an isolated femur fracture had a leg length discrepancy > 2 cm. There were no pin site infections requiring intravenous antibiotics or additional surgery. One patient with Blount disease and previous tibial osteotomy developed transient peroneal nerve palsy. Despite improvements in pin design and predictable fracture healing, complications such as refracture and leg length discrepancy after external fixation of pediatric femoral shaft fractures can occur. However, external fixation remains a viable alternative for certain fractures such as length-unstable fractures, metadiaphyseal

  10. Intramedullary nail versus dynamic compression plate fixation in treating humeral shaft fractures: grading the evidence through a meta-analysis.

    Directory of Open Access Journals (Sweden)

    JianXiong Ma

    Full Text Available There is a debate regarding the choice of operative intervention in humeral shaft fractures that require surgical intervention. The choices for operative interventions include intramedullary nailing (IMN and dynamic compression plate (DCP. This meta-analysis was performed to compare fracture union, functional outcomes, and complication rates in patients treated with IMN or DCP for humeral shaft fractures and to develop GRADE (Grading of Recommendations, Assessment, Development, and Evaluation-based recommendations for using the procedures to treat humeral shaft fractures. A systematic search of all the studies published through December 2012 was conducted using the Medline, Embase, Sciencedirect, OVID and Cochrane Central databases. The randomized controlled trials (RCTs and quasi-RCTs that compared IMN with DCP in treating adult patients with humeral shaft fractures and provided data regarding the safety and clinical effects were identified. The demographic characteristics, adverse events and clinical outcomes were manually extracted from all of the selected studies. Ten studies that included a total of 448 patients met the inclusion criteria. The results of a meta-analysis indicated that both IMN and DCP can achieve similar fracture union with a similar incidence of radial nerve injury and infection. IMN was associated with an increased risk of shoulder impingement, more restriction of shoulder movement, an increased risk of intraoperative fracture comminution, a higher incidence of implant failure, and an increased risk of re-operation. The overall GRADE system evidence quality was very low, which reduces our confidence in the recommendations of this system. DCP may be superior to IMN in the treatment of humeral shaft fractures. Because of the low quality evidence currently available, high-quality RCTs are required.

  11. Intertrochanteric fractures in elderly high risk patients treated with Ender nails and compression screw

    Directory of Open Access Journals (Sweden)

    Gangadharan Sidhartha

    2010-01-01

    Full Text Available Background: Ender and Simon Weidner popularized the concept of closed condylocephlic nailing for intertrochanteric fractures in 1970. The clinical experience of authors revealed that Ender nailing alone cannot provide secure fixation in elderly patients with osteoporosis. Hence we conducted a study to evaluate the efficacy of a combined fixation procedure using Ender nails and a cannulated compression screw for intertrochanteric fractures. Materials and Methods: 76 patients with intertrochanteric fractures were treated using intramedullary Ender nails and cannulated compression screw from January 2004 to December 2007. The mean age of the patients was 80 years (range 70-105 years.Using the Evan′s system of classification 49 were stable and 27 unstable fractures. Inclusion criteria was high risk elderly patients (age > 70 years with intertrochanteric fracture. The exclusion criteria included patients with pressure sores over the trochanteric region. Many patients had pre-existing co-morbidities like diabetes mellitus, hypertension, COPD, ischemic heart disease, CVA and coronary artery bypass surgery. The two Ender nails of 4.5mm each were passed across the fracture site into the proximal neck. This was reinforced with a 6.5 mm cannulated compression screw passed from the sub trochanteric region, across the fracture into the head. Results: The mean follow-up was 14 months (range 9-19 months Average time to fracture union was 10 weeks (range 6-16 weeks. The mean knee ROM was 130o (± 5o. There was no case of nail penetration into hip joint. In five cases with advanced osteoporosis there was minimal migration of Ender nails distally. Conclusions: The Ender nailing combined with compression screw fixation in cases of intertrochanteric fractures in high risk elderly patients could achieve reliable fracture stability with minimal complications.

  12. A study on management of extracapsular trochanteric fractures by proximal femoral nail

    Directory of Open Access Journals (Sweden)

    K Ramaprathap Reddy

    2016-01-01

    Full Text Available Background: Trochanteric fractures of femur like intertrochanteric and subtrochanteric fractures are a leading cause of hospital admissions in elderly people. Conservative methods of treatment results in malunion with shortening and limitation of hip movement as well as complications of prolonged immobilizations such as bed sores, deep vein thrombosis, and respiratory infections. This study is done to analyze the surgical management of trochanteric fractures of the femur using a proximal femoral nail (PFN. Methodology: This is a prospective study of 40 cases of trochanteric and subtrochanteric fractures admitted to Government General Hospital, Vijayawada, Andhra Pradesh. Cases were taken according to inclusion and exclusion criteria, i.e., patients with trochanteric fractures femur above the age of 20 years. Medically unsuitable, open fractures and patients not willing for surgery were excluded from the study. Results: Forty percentage of cases were admitted due to slip and fall and with a slight predominance of the right side. Out of 40 cases, 26 were trochanteric, and 14 were subtrochanteric. In trochanteric class, 37.5% were body and griffin Type 2, in subtrochanteric class 12.5% were sinsheimer Type 3a and 10% were 2b. Out of 30 remaining cases, 25 were trochanteric, and 05 were subtrochanteric. Good to excellent results are seen in 100% cases of trochanteric fractures and 90% cases in subtrochanteric fractures. Conclusion: From this sample study, we consider that PFN is an excellent implant for the treatment of pertrochanteric fractures. The terms of successful outcome include a good understanding of fracture biomechanics, proper patient selection, good preoperative planning, accurate instrumentation, good image intensifier, and exactly performed osteosynthesis.

  13. Avaliação do emprego da haste femoral curta na fratura trocantérica instável do fêmur Evaluating the use of a proximal femoral nail in unstable trochanteric fracture of the femur

    Directory of Open Access Journals (Sweden)

    João Antonio Matheus Guimarães

    2008-09-01

    , devido a uma redução inadequada em varo, ocorreu um cutout que necessitou de revisão cirúrgica. Outro caso de fratura do tipo 31A2, evoluiu para necrose avascular da cabeça femoral, após consolidação da fratura. Por fim, um caso de fratura do tipo 31A3, devido a redução inadequada no plano sagital, evoluiu para retarde de consolidação, com quebra da haste após 13 meses da cirurgia. CONCLUSÃO: A osteossíntese com haste proximal, como tratamento da fratura trocantérica instável do fêmur realizada em pacientes com idade superior a 60 anos, resultou na consolidação da maioria dos casos. As complicações foram distintas nos dois subgrupos estudados. A redução adequada da fratura antes da introdução da haste intramedular é fundamental para o sucesso do procedimento.OBJECTIVE: Identifying the rate of healing of unstable trochanteric fractures submitted to osteosynthesis with a proximal femoral nail (PFN® - AO/ASIF, in patients operated on between November 1999 and March 2004. METHODS: 45 patients were analyzed, ages ranging from 60 to 93, with unstable trochanteric fractures of the femur submitted to osteosynthesis with short PFN®, with indirect reduction in a traction device guided by radioscopy. The fractures were classified according to the AO/OTA classification. Bone quality was evaluated by the Singh index in the post-operative radiographic routine. The quality of the reduction achieved and the positioning of the implant were evaluated by post-operative anteroposterior and profile X-ray of the proximal femur, with analysis of the cervicodiaphyseal angle and the distance between the tip of the sliding nail and the center of the femoral head, the so-called "tip apex distance" (TAD. RESULTS: The mean age of patients studied was 80.8 years (60-93. Females prevailed, with 37 cases (82.2%. The right side was involved in 22 cases (48.89% and the left side, in 23 (51.1%. All fractures were unstable, 22 of them of the type 31A2 (48.8%, and 23, of the

  14. Intramedullary tuberculoma: A case report

    International Nuclear Information System (INIS)

    Maamar, M.; El Quessar, A.; El Fatemi, N.; El Hassani, My R.; Chakir, N.; Jiddane, M.

    2007-01-01

    Study design: We report a case of intra-medullary tuberculoma in a 22 year-old man with progressive paraparesis and sphincter dysfunction. Objectives: To present a case of intra-medullary tuberculosis and to describe the MRI's contribution to the diagnosis. Summary of background data: Intra-medullary spinal tuberculoma is a rare form of central nervous system tuberculosis. The subject and diagnosis methods: The patient, a 22 year-old man, presented with an intra-medullary tuberculoma of the dorsal spinal cord diagnosed after 6 month history of progressive paraparesis and sphincter dysfunction. MRI visualized ring enhancement of the intra-medullary dorsal lesion. Results: Total resection of the intra-medullary mass was performed through a posterior myelotomy. Histological examination revealed a granulomatous necrosis with caseum. The patient was treated with four anti-tuberculosis drugs in association with corticotherapy. The paraparesis and sphincter dysfunction improved. Conclusions: Intra-medullary spinal tuberculoma is rare, but must be considered in the differential diagnosis of spinal cord compression

  15. Interventions for treating femoral shaft fractures in children and adolescents.

    Science.gov (United States)

    Madhuri, Vrisha; Dutt, Vivek; Gahukamble, Abhay D; Tharyan, Prathap

    2014-12-01

    Fractures of the femoral shaft in children are relatively uncommon but serious injuries that disrupt the lives of children and their carers and can result in significant long-term disability. Treatment involves either surgical fixation, such as intramedullary nailing or external fixation, or conservative treatment involving prolonged immobilisation, often in hospital. To assess the effects (benefits and harms) of interventions for treating femoral shaft fractures in children and adolescents. We searched the Cochrane Bone, Joint and Muscle Trauma Group Specialised Register (accessed 16 August 2013), the Cochrane Central Register of Controlled Trials (The Cochrane Library 2013 Issue 7), MEDLINE (1946 to August Week 1 2013), EMBASE (1980 to 2012 week 9), CINAHL (16 August 2013), clinical trials registries, conference proceedings and reference lists; and contacted trial authors and experts in the field. Randomised and quasi-randomised controlled trials comparing conservative and surgical interventions for diaphyseal fractures of the femur in children under 18 years of age. Our primary outcomes were functional outcome measures, unacceptable malunion, and serious adverse events. Two authors independently screened and selected trials, assessed risk of bias and extracted data. We assessed the overall quality of the evidence for each outcome for each comparison using the GRADE approach. We pooled data using a fixed-effect model. We included 10 trials (six randomised and four quasi-randomised) involving a total of 527 children (531 fractures). All trials were at some risk of bias, including performance bias as care provider blinding was not practical, but to a differing extent. Just one trial was at low risk of selection bias. Reflecting both the risk of bias and the imprecision of findings, we judged the quality of evidence to be 'low' for most outcomes, meaning that we are unsure about the estimates of effect. Most trials failed to report on self-assessed function or when

  16. Avascular necrosis of the femoral head at 2 years after pertrochanteric fracture surgery: Case report.

    Science.gov (United States)

    Deleanu, Bogdan; Prejbeanu, Radu; Vermesan, Dinu; Honcea, Lucian; Mioc, Mihail Lazar; Tsiridis, Eleftherios; Predescu, Vlad

    2016-02-01

    The avascular necrosis of the femoral head represents the death of bone tissue due to the lack of blood supply. The disease has a progressive evolution and left untreated leads to femoral head collapse and severe arthritis. We present a case of a pertrochanteric fracture which has been successfully operated with a dynamic interlocking trochanteric gamma nail on the right hip. At 2 years after surgery the patient developed an incipient avascular necrosis of the femoral head. Despite the good positioning of the implant, we considered that the source of the pain was an intolerance of the implant, and thus we removed it. After implant removal, the patient was kept under observation and conservative treatment, to prevent further damage to the right hip and allow the healing to occur. At 6 months after the gamma nail was removed the X-rays revealed advanced avascular necrosis of the femoral head and secondary osteoarthritis on the right hip. The patient underwent surgery with an uncemented total hip arthroplasty. There are a few discussions regarding the avascular necrosis of the femoral head. These discussions may include the predisposing risk factors, the treatment of choice and the postoperative complications. The avascular necrosis of the femoral head is a complication of pertrochanteric fractures that can not be foreseen or avoided. The optimal treatment in these cases is uncemented total hip arthroplasty.

  17. The use of blocking screws with internal lengthening nail and reverse rule of thumb for blocking screws in limb lengthening and deformity correction surgery

    Directory of Open Access Journals (Sweden)

    Saravanaraja Muthusamy

    2016-09-01

    Full Text Available Abstract Internal lengthening nail (ILN is a recent development in limb lengthening and deformity correction specialty. The ILN has the distinct advantage of combining acute deformity correction with gradual lengthening of bone. While using ILN, the short metaphyseal bone fragment may develop a deformity at the time of osteotomy and nail insertion or during bone lengthening because of the wide medullary canal. These deformities are typically predictable, and blocking screws (Poller screws are helpful in these situations. This manuscript describes the common deformities that occur in femur and tibia with osteotomies at different locations while using ILN in antegrade and retrograde nailing technique. Also, a systematic approach to the appropriate use of blocking screws in these deformities is described. In addition, the “reverse rule of thumb” is introduced as a quick reference to determine the ideal location(s and number of blocking screws. These principles are applicable to limb lengthening and deformity correction as well as fracture fixation using intramedullary nails.

  18. The use of blocking screws with internal lengthening nail and reverse rule of thumb for blocking screws in limb lengthening and deformity correction surgery.

    Science.gov (United States)

    Muthusamy, Saravanaraja; Rozbruch, S Robert; Fragomen, Austin T

    2016-11-01

    Internal lengthening nail (ILN) is a recent development in limb lengthening and deformity correction specialty. The ILN has the distinct advantage of combining acute deformity correction with gradual lengthening of bone. While using ILN, the short metaphyseal bone fragment may develop a deformity at the time of osteotomy and nail insertion or during bone lengthening because of the wide medullary canal. These deformities are typically predictable, and blocking screws (Poller screws) are helpful in these situations. This manuscript describes the common deformities that occur in femur and tibia with osteotomies at different locations while using ILN in antegrade and retrograde nailing technique. Also, a systematic approach to the appropriate use of blocking screws in these deformities is described. In addition, the "reverse rule of thumb" is introduced as a quick reference to determine the ideal location(s) and number of blocking screws. These principles are applicable to limb lengthening and deformity correction as well as fracture fixation using intramedullary nails.

  19. Immediate versus delayed intramedullary nailing for open fractures of the tibial shaft: A multivariate analysis of factors affecting deep infection and fracture healing

    Directory of Open Access Journals (Sweden)

    Yokoyama Kazuhiko

    2008-01-01

    Full Text Available Background: The purpose of this study was to evaluate contributing factors affecting deep infection and fracture healing of open tibia fractures treated with locked intramedullary nailing (IMN by multivariate analysis. Materials and Methods: We examined 99 open tibial fractures (98 patients treated with immediate or delayed locked IMN in static fashion from 1991 to 2002. Multivariate analyses following univariate analyses were derived to determine predictors of deep infection, nonunion, and healing time to union. The following predictive variables of deep infection were selected for analysis: age, sex, Gustilo type, fracture grade by AO type, fracture location, timing or method of IMN, reamed or unreamed nailing, debridement time (≤6 h or> 6 h, method of soft-tissue management, skin closure time (≤1 week or> 1 week, existence of polytrauma (ISS< 18 or ISS≥18, existence of floating knee injury, and existence of superficial/pin site infection. The predictive variables of nonunion selected for analysis was the same as those for deep infection, with the addition of deep infection for exchange of pin site infection. The predictive variables of union time selected for analysis was the same as those for nonunion, excluding of location, debridement time, and existence of floating knee and superficial infection. Results: Six (6.1%; type II Gustilo n=1, type IIIB Gustilo n=5 of the 99 open tibial fractures developed deep infections. Multivariate analysis revealed that timing or method of IMN, debridement time, method of soft-tissue management, and existence of superficial or pin site infection significantly correlated with the occurrence of deep infection ( P < 0.0001. In the immediate nailing group alone, the deep infection rate in type IIIB + IIIC was significantly higher than those in type I + II and IIIA ( P = 0.016. Nonunion occurred in 17 fractures (20.3%, 17/84. Multivariate analysis revealed that Gustilo type, skin closure time, and

  20. Intramedullary Venous Drainage System for Distal Fingertip Replantations.

    Science.gov (United States)

    Purisa, Husrev; Ozturk, Muhammed Besir; Kabakas, Fatih; Mersa, Berkan; Ozcelik, Ismail Bulent; Sezer, Ilker

    2017-08-01

    The number of venous anastomoses performed during fingertip replantation is one of the most important factors affecting the success of replantation. However, because vessel diameters decrease in the zone 1 level, vessel anastomoses, especially vein anastomoses, are technically difficult and, thus, cannot be performed in most cases. Alternative venous drainage methods are crucial when any reliable vein repair is not possible. In the literature, so many artery-only replantation techniques have been defined, such as arteriovenous anastomoses, forming an arteriovenous or venocutaneous fistula, manual milking and massage, puncturing, and external bleeding via a fishmouth incision and using a medical leech. It has been shown that, in distal fingertip replantations, the medullary cavity may also be a good way for venous return. In this study, we introduce an alternative intramedullary venous drainage system we developed to facilitate venous drainage in artery-only fingertip replantations. The results of 24 fingertip replantations distal to the nail fold by using this system are presented with a literature review.

  1. Nail cosmetics

    Directory of Open Access Journals (Sweden)

    Nina A Madnani

    2012-01-01

    Full Text Available The nail as an anatomic structure protects the terminal phalanx of the digit from injury. Historically, it has served as a tool for protection and for survival. As civilizations developed, it attained the additional function of adornment. Nail beautification is a big industry today, with various nail cosmetics available, ranging from nail hardeners, polishes, extensions, artificial/sculpted nails, and nail decorations. Adverse events may occur either during the nail-grooming procedure or as a reaction to the individual components of the nail cosmetics. This holds true for both the client and the nail technician. Typically, any of the procedures involves several steps and a series of products. Separate "nail-bars" have been set up dedicated to serve women and men interested in nail beautification. This article attempts to comprehensively inform and educate the dermatologist on the services offered, the products used, and the possible/potential adverse effects related to nail-grooming and nail cosmetics.

  2. Nail cosmetics.

    Science.gov (United States)

    Madnani, Nina A; Khan, Kaleem J

    2012-01-01

    The nail as an anatomic structure protects the terminal phalanx of the digit from injury. Historically, it has served as a tool for protection and for survival. As civilizations developed, it attained the additional function of adornment. Nail beautification is a big industry today, with various nail cosmetics available, ranging from nail hardeners, polishes, extensions, artificial/sculpted nails, and nail decorations. Adverse events may occur either during the nail-grooming procedure or as a reaction to the individual components of the nail cosmetics. This holds true for both the client and the nail technician. Typically, any of the procedures involves several steps and a series of products. Separate "nail-bars" have been set up dedicated to serve women and men interested in nail beautification. This article attempts to comprehensively inform and educate the dermatologist on the services offered, the products used, and the possible/potential adverse effects related to nail-grooming and nail cosmetics.

  3. Fatigue failure of the cephalomedullary nail: revision options, outcomes and review of the literature.

    Science.gov (United States)

    Tucker, Adam; Warnock, Michael; McDonald, Sinead; Cusick, Laurence; Foster, Andrew P

    2018-04-01

    Cephalomedullary nail (CMN) failure is a rare entity following hip fracture treatment. However, it poses significant challenges for revision surgery, both mechanically and biologically. Nail failure rates have been reported at failure, compared to "adequate" and "good" (p = 0.027). Tip-Apex Distance (TAD) mean was 23.2 ± 8.3 mm, and an adequate TAD with three-point fixation was seen in only 35% of cases. Mean time to failure was 401.0 ± 237.2 days, with mean age at failure of 74.0 ± 14.8 years. Options after failure included revision CMN nail, proximal femoral locking plate (PFLP), long-stem or restoration arthroplasty, or femoral endoprosthesis. Barthel Functional Index scores showed no significant difference at 3 and 12 months post-operatively, nor any difference between treatment groups. Mean 12-month mortality was 30%, akin to a primary hip fracture mortality risk according to NICE guidelines. Mortality rates were lowest in revision nails. Subsequent revision rates were higher in the PFLP group. There is no reported evidence on the best surgical technique for managing the failed CMN, with no clear functional benefit in the options above. Good surgical technique at the time of primary CMN surgery is critical in minimising fatigue failure. After revision, overall mortality rates were equivalent to reported primary hip fracture mortality rates. Further multicentre evaluations are required to assess which technique convey the best functional outcomes without compromising 12-month mortality rates.

  4. Three-Dimensional Analysis of the Characteristics of the Femoral Canal Isthmus: An Anatomical Study

    Directory of Open Access Journals (Sweden)

    Xiu-yun Su

    2015-01-01

    Full Text Available Purpose. To establish a new approach for measuring and locating the femoral intramedullary canal isthmus in 3-dimensional (3D space. Methods. Based on the computed tomography data from 204 Chinese patients, 3D models of the whole femur and the corresponding femoral isthmus tube were reconstructed using Mimics software (Materialise, Haasrode, Belgium. The anatomical parameters of the femur and the isthmus, including the femur length and radius, and the isthmus diameter and height, were measured accordingly. Results. The mean ratio of the isthmus height versus the femoral height was 55 ± 4.8%. The mean diameter of the isthmus was 10.49 ± 1.52 mm. The femoral length, the isthmus diameter, and the isthmus tube length were significantly larger in the male group. Significant correlations were observed between the femoral length and the isthmus diameter (r=0.24, p<0.01 and between the femoral length and the isthmus height (r=0.6, p<0.01. Stepwise linear regression analyses demonstrated that the femoral length and radius were the most important factors influencing the location and dimension of the femoral canal isthmus. Conclusion. The current study developed a new approach for measuring the femoral canal and for optimization of customer-specific femoral implants.

  5. Implant failure in lower limb long bone diaphyseal fractures at a tertiary hospital in Ile- Ife. Nigeria.

    Science.gov (United States)

    Esan, O; Ikem, I C; Orimolade, E A; Esan, O T

    2014-06-01

    This included determining aetiology of failure and comparing the failure rate in implant fixations using solid intramedullary nail and DCP. A retrospective study conducted at the Orthopaedic Department, Obafemi Awolowo University Teaching Hospital, Ile-Ife,Nigeria. Records of all operated cases of lower limb long bone diaphyseal fractures including those with failed fixations from August 2006-July 2011 were reviewed. Data retrieved included type of implant used, aetiology and characteristics of Implant failure. Data were analysed using SPSS version 16. Frequency distribution of the variables of interest was done. Difference in failure rate of intramedullary nail versus DCP was tested using chi-square. Statistical significance was inferred at pfractures and met inclusion criteria, of which 135 had intramedullary nail fixation and 86 had DCP. The rate of implant failure in intramedullary nail was 1.5% while it was 5.8% in patients with DCP (p=0.113; 0R=4.10; 95% CI=0.65- 43.77). Implant fracture was the commonest type of failure seen (100% versus 60%) and non union was the commonest cause of failure seen (50% versus 40%) in the intramedullary nailing and DCP groups respectively. The likelihood of a failed implant is higher in fixations done with DCP compared with intramedullary nail though the difference was not statistically significant. Commonest reason for failure in both groups was non-union. Findings from this study may guide surgeons in choice of implant in the management of long bone fractures.

  6. Median nail dystrophy involving the thumb nail

    Directory of Open Access Journals (Sweden)

    Rahulkrishna Kota

    2016-01-01

    Full Text Available Median canaliform dystrophy of Heller is a rare entity characterized by a midline or a paramedian ridge or split and canal formation in nail plate of one or both the thumb nails. It is an acquired condition resulting from a temporary defect in the matrix that interferes with nail formation. Habitual picking of the nail base may be responsible for some cases. Histopathology classically shows parakeratosis, accumulation of melanin within and between the nail bed keratinocytes. Treatment of median nail dystrophy includes injectable triamcinalone acetonide, topical 0.1% tacrolimus, and tazarotene 0.05%, which is many a times challenging for a dermatologist. Psychiatric opinion should be taken when associated with the depressive, obsessive-compulsive, or impulse-control disorder. We report a case of 19-year-old male diagnosed as median nail dystrophy.

  7. Type II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN Versus Dynamic Hip Screw(DHS

    Directory of Open Access Journals (Sweden)

    Cyril Jonnes

    2016-01-01

    Full Text Available Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN, in Type II intertrochanteric fractures (Boyd and Griffin classification. This study was done to compare the functional and radiological outcome of PFN with DHS in treatment of Type II intertrochanteric fractures.   Methods: From October 2012 to March 2015, a prospective comparative study was done where 30 alternative cases of type II intertrochanteric fractures of hip were operated using PFN or DHS. Intraoperative complications were noted. Functional outcome was assessed using Harris Hip Score and radiological findings were compared at 3, 6, and 12 months postoperatively. Results: The average age of the patients was 60 years. In our series we found that patients with DHS had increased intraoperative blood loss (159ml, longer duration of surgery (105min, and required longer time for mobilization while patients who underwent PFN had lower intraoperative blood loss (73ml, shorter duration of surgery (91min, and allowed early mobilization. The average limb shortening in DHS group was 9.33 mm as compared with PFN group which was only 4.72 mm. The patients treated with PFN started early ambulation as they had better Harris Hip Score in the early post-op period. At the end of 12th month, there was not much difference in the functional outcome between the two groups. Conclusion: PFN is better than DHS in type II inter-trochanteric fractures in terms of decreased blood loss, reduced duration of surgery, early weight bearing and mobilization, reduced hospital stay, decreased risk of infection and decreased complications.

  8. Recurrence of a Unicameral Bone Cyst in the Femoral Diaphysis.

    Science.gov (United States)

    Kim, Hyun Se; Lim, Kyung Sup; Seo, Sung Wook; Jang, Seung Pil; Shim, Jong Sup

    2016-12-01

    Diaphyseal unicameral bone cysts of the long bone are generally known to originate near the growth plate and migrate from the metaphysis to the diaphysis during skeletal growth. In the case of unicameral bone cysts of diaphyseal origin, recurrence at the same location is extremely rare. We report a case of recurrence of a unicameral bone cyst in the diaphysis of the femur that developed 8 years after treatment with curettage and bone grafting. We performed bone grafting and lengthening of the affected femur with an application of the Ilizarov apparatus over an intramedullary nail to treat the cystic lesion and limb length discrepancy simultaneously.

  9. Failure of fixation of trochanteric femur fractures: Clinical recommendations for avoiding Z-effect and reverse Z-effect type complications

    Directory of Open Access Journals (Sweden)

    Balbachevsky Daniel

    2011-06-01

    Full Text Available Abstract Background Z-effect and reverse Z-effect are complications that arise from the surgical treatment of pertrochanteric fractures of the femur with proximal femoral nails (PFN comprising two interlocking head screws. Such complications are induced by the migration of screws in opposite directions, which may lead to failure of the osteosynthesis. Findings The paper describes three cases of pertrochanteric fractures that were treated with PFN with two interlocking screws that evolved to either Z-effect or reverse Z-effect. Literature-based explanations for this phenomenon are provided together with recommendations of how to avoid such complications. Conclusions Although intramedullary fixation is an established method of treatment of femoral intertrochanteric and subtrochanteric fractures, the evolution of the procedure may include complications associated with the migration of the interlocking head screws. The occurrence of Z-effect and reverse Z-effect has not been completely elucidated, but the main causes of such complications are probably fracture fixation in varus position, severe medial comminution, inappropriate entry point of the nail and poor bone quality.

  10. Case series

    African Journals Online (AJOL)

    abp

    30 mai 2017 ... All patients underwent systematic plaster immobilization for a period of ... On average, nails were removed after about 6 ... cases), osteitis associated with material (2 cases), refracture (3 ... Although intramedullary nailing ideally is an osteosynthesis ..... intramedullary fixation of pediatric forearm fractures.

  11. A Study of Inflammatory/Necrosis Biomarkers in the Fracture of the Femur Treated with Proximal Femoral Nail Antirotation

    Directory of Open Access Journals (Sweden)

    Mariapaola Marino

    2015-01-01

    Full Text Available Pertrochanteric fractures are common injuries in adults and source of morbidity and mortality among the elderly. Different surgical techniques were recommended for their treatment but undoubtedly they add an additional inflammatory trauma along the fracture itself. Many attempts to quantify the degree of approach-related trauma are carried out through measurements of systemic inflammatory parameters. In this study we prospectively analyzed laboratory data of 20 patients over eighty with pertrochanteric fracture of the femur treated with proximal femoral nail antirotation (PFNA. This is an excellent device for osteosynthesis because it can be easily and quickly inserted by a mini-incision providing stable fixation and early full mobilization. Serum tumor necrosis factor-alpha (TNF-α, interleukin-6 (IL-6, C-reactive protein (CRP, and plasma creatin kinase (CK were evaluated 1 hour preoperatively and 24 hours postoperatively. Our results show that PFNA did not induce significant increments in serum levels of inflammatory cytokines TNF-α and IL-6; CRP was elevated preoperatively in correlation with waiting time for surgery; CRP and CK showed a significant increment in the first postoperatory day; CK increment was correlated with surgical time length. We conclude that, for the markers we analyzed, PFNA shows a low biomechanical-inflammatory profile that represents an advantage over other techniques.

  12. Strategies for Proximal Femoral Nailing of Unstable Intertrochanteric Fractures: Lateral Decubitus Position or Traction Table.

    Science.gov (United States)

    Sonmez, Mesut Mehmet; Camur, Savas; Erturer, Erden; Ugurlar, Meric; Kara, Adnan; Ozturk, Irfan

    2017-03-01

    The aim of this prospective randomized study was to compare the traction table and lateral decubitus position techniques in the management of unstable intertrochanteric fractures. Eighty-two patients with unstable intertrochanteric fractures between 2011 and 2013 were included in this study. All patients were treated surgically with the Proximal Femoral Nail Antirotation implant (DePuy Synthes). Patients were randomized to undergo the procedure in the lateral decubitus position (42 patients) or with the use of a traction table (40 patients). Patients whose procedure was not performed entirely with a semi-invasive method or who required the use of additional fixation materials, such as cables, were excluded from the study. The groups were compared on the basis of the setup time, surgical time, fluoroscopic exposure time, tip-to-apex distance, collodiaphyseal angle, and modified Baumgaertner criteria for radiologic reduction. The setup time, surgical time, and fluoroscopic exposure time were lower and the differences were statistically significant in the lateral decubitus group compared with the traction table group. The collodiaphyseal angles were significantly different between the groups in favor of the lateral decubitus method. The tip-to-apex distance and the classification of reduction according to the modified Baumgaertner criteria did not demonstrate a statistically significant difference between the groups. The lateral decubitus position is used for most open procedures of the hip. We found that this position facilitates exposure for the surgical treatment of unstable intertrochanteric fractures and has advantages over the traction table in terms of set up time, surgical time and fluoroscopic exposure time.

  13. Traumatic subchondral fracture of the femoral head in a healed trochanteric fracture.

    Science.gov (United States)

    Lee, Sang Yang; Niikura, Takahiro; Iwakura, Takashi; Kurosaka, Masahiro

    2014-07-11

    An 82-year-old woman sustained a trochanteric fracture of the left femur after a fall. Fracture fixation was performed using proximal femoral nail antirotation (PFNA) II, and she was able to walk with a T-cane after 3 months. Eleven months following the operation, the patient presented with left hip pain after a fall. Radiographs showed a subchondral collapse of the femoral head located above the blade tip. The authors removed the PFNA-II and subsequently performed cemented bipolar hemiarthroplasty. Histological evaluation of the femoral head showed osteoporosis with no evidence of osteonecrosis. Repair tissue, granulation tissue and callus formation were seen at the collapsed subchondral area. Based on these findings, a traumatic subchondral fracture of the femoral head in a healed trochanteric fracture was diagnosed. A traumatic subchondral fracture of the femoral head may need to be considered as a possible diagnosis after internal fixation of the trochanteric fracture. 2014 BMJ Publishing Group Ltd.

  14. Reaming and the healing of fractures | Umebese | Nigerian Journal ...

    African Journals Online (AJOL)

    OBJECTIVE: We quantified fracture healing response in the intramedullary nailed fractures of femur. PATIENTS AND METHOD: By a simple method of measuring size and mass of callus formation radiologically in 30 patients who had undergone open retrograde intramedullary Kuntscher nailing. We then compared the ...

  15. Influence of Lateral Muscle Loading in the Proximal Femur after Fracture Stabilization with a Trochanteric Gamma Nail (TGN)

    Science.gov (United States)

    Sitthiseripratip, Kriskrai; Mahaisavariya, Banchong; Suwanprateeb, Jintamai; Bohez, Erik; Vander Sloten, Jos

    The purpose of this study was to investigate the influence of lateral muscle loading on the stress/strain distributions of the trochanteric Gamma nail (TGN) fixation within the healed, trochanteric and subtrochanteric femoral fractures by means of a finite element method. The effect of three muscle groups, the abductors (ABD), the vastus lateralis (VL) and the iliotibial band (ITB), were investigated. The analytical results showed that addition of lateral muscle forces, iliotibial band and vastus lateralis, produced compensation of forces and reduction of bending moments in the bone and in the trochanteric Gamma nail especially in the lateral aspect. The iliotibial band produced a higher impact as compared to the vastus lateralis. Therefore in the finite element analysis of the proximal femur with the trochanteric Gamma nail fracture fixation should include the lateral muscle forces to simulate load condition with maximal physiological relevance to the closed nailing technique.

  16. Avaliação do uso de haste bloqueada e bloqueio transcortical no reparo de fraturas diafisárias de fêmur em felinos Evaluation of the use of interlocking nail and transcortical blockade for the repair of diaphyseal fractures of the femur in cats

    Directory of Open Access Journals (Sweden)

    Leandro Romano

    2008-04-01

    fracture stabilization and present biomechanical advantages when compared to other immobilization techniques. It acts along the central mechanical axis of the bone and preserves biological concept standards for osteosynthesis. The use of interlocking nail in cats is limited because the intramedullary space is relatively small for the available nail sizes. We reported 10 cases of cats that had simple or multiple closed fractures of the femoral diaphysis. The animals weighed 3.5 to 5 kg , which allowed using nails of 4.0mm and 4.7mm in diameter. For the nail insertion, retrograde and normograde routs were used, and four 2mm titanium screws were used to lock all the perforations. No trans-surgical complication occurred, however, due to a new trauma, one of the animals suffered femoral neck fracture and transversal distal fracture to the nail, three days after surgery. Radiographies were made up to four months after surgery, and in most cases secondary bone formation was seen, showing bone consolidation in 61-89 days, excluding the animal who suffered new trauma, who presented bone healing in 150 days. Clinically, occasional lameness occurred; however, except for the animal that had new trauma, all animals initiated adequate limb support in 3 to 8 days after surgery. In conclusion, the use of 4.0mm and 4.7mm interlocking nails in felines was adequate, with bone healing in all cases, and also return of good limb function after surgery.

  17. Radiological assessment of the femoral bowing in Japanese population

    Directory of Open Access Journals (Sweden)

    Abdelaal Ahmed Hamed Kassem

    2016-01-01

    Full Text Available Introduction: Differences in the magnitude of bowing between races are well-known characteristics of the femur. Asian races have an increased magnitude of femoral bowing but most of the orthopedic implants designed for the femur do not match this exaggerated bowing. We calculated the sagittal and coronal femoral bowing in the Japanese population at different levels of the femur and addressed its surgical significance. Material and methods: We calculated the sagittal and coronal bowing of 132 Japanese femora using CT scan of the femur. A mathematical calculation of the radius of curvature at proximal, middle, and distal regions of the femur was used to determine the degree of femoral bowing. Results: Mean sagittal bowing of the femur was 581, 188, and 161 mm for the proximal, middle, and distal thirds of the femur and mean lateral bowing was 528, 5092, and 876 mm, respectively. Mean sagittal and coronal bowing for the whole femur was 175 and 2640 mm, respectively. No correlation was found between age, gender, length of femur, and the degree of bowing. Conclusion: Our study reveals that femoral bowing in the Japanese population is 175 mm in the sagittal plane and 2640 mm in the coronal plane; these values are greater than the femoral bowing in other ethnic groups studied in the literature. This may result in varying degrees of mismatch between the western-manufactured femoral intramedullary implants and the Japanese femur. We recommend that orthopedic surgeons to accurately perform preoperative evaluation of the femoral bowing to avoid potential malalignment, rotation, and abnormal stresses between the femur and implant.

  18. Treatment Concepts of Osteogenesis Imperfecta

    Directory of Open Access Journals (Sweden)

    Ramji Lal Sahu

    2012-06-01

    Full Text Available Background: To explore the Application of the intramedullary nails for correction of deformity in the lower limbs and decrease the opportunity of refractures in children with osteogenesis imperfecta.Materials and Methods: From July 2005 to July 2009, 11 patients (5 males and 6 females, were recruited from Emergency and outpatient department having deformities of osteogenesis imperfecta in lower limbs. With 3 femurs and 5 tibias with deformity in lower limps were corrected by multiosteotomy and fixed with intramedullary interlocking nails, 6 (3 femurs and 3 tibias for Rush nails; 6 (2 femurs and 4 tibias for Ender nails; and 12 (6 femurs and 6 tibias for flexible intramedullary nails. All patients were operated under general or spinal anesthesia. Results: All deformities were perfectly corrected. All patients were available at final follow up, for 9 months to 36 months, mean 18 months. 2 patients had delayed union, 2 had superficial infection in the incision or pin tract, and 1 had refractures postoperatively. The results were excellent in 72.727% and good in 27.272% patients. Conclusion: Multiosteotomy and fixed intramedullary nails can correct the deformity in the lower limbs perfectly and decrease the opportunity of refractures in children with osteogenesis imperfecta, which has been proved to be a reliable method.

  19. Tension band plating of a nonunion anterior tibial stress fracture in an athlete.

    Science.gov (United States)

    Merriman, Jarrad A; Villacis, Diego; Kephart, Curtis J; Rick Hatch, George F

    2013-07-01

    The authors present a rare technique of tension band plating of the anterior tibia in the setting of a nonunion stress fracture. Surgical management with an intramedullary nail is a viable and proven option for treating such injuries. However, in treating elite athletes, legitimate concerns exist regarding the surgical disruption of the extensor mechanism and the risk of anterior knee pain associated with intramedullary nail use. The described surgical technique demonstrates the use of tension band plating as an effective treatment of delayed union and nonunion anterior tibial stress fractures in athletes without the potential risks of intramedullary nail insertion. Copyright 2013, SLACK Incorporated.

  20. Treating Simple Tibia Fractures with Poly-DL-Lactic Acid Screw as a ...

    African Journals Online (AJOL)

    Purpose: To investigate the curative effect of poly-DL-lactic acid (PDLLA) absorbable screw as a locked intramedullary nail for simple tibia fractures. Methods: In this study, 35 patients treated with the PDLLA screw were observed, and another 35 patients treated with a traditional locking intramedullary nail were treated as ...

  1. The surgical manegement of metastases to humerus-clinical evaluation.

    Science.gov (United States)

    Chrobok, Adam; Spindel, Jerzy; Miszczyk, Leszek; Koczy, Bogdan; Pilecki, Bogdan; Jarosz, Adam; Mrozek, Tomasz

    2003-06-30

    Background. The humerus is a common localisation of cancer metastases. The restoration of anatomical order and tumor resection within humerus is important for patients quality of everyday life and for their pain relief. The surgical treatment is one of the most important part of the whole oncological ways of tratment. The study objective was a clinical assesment of tumor resection and reconstruction within humerus according to matastasis localisation and the choice of surgical technique. Material and methods. In the years 1999-2002 19 patients underwent surgery due to pathological fracture or/and cancer metastasis within humerus. The shaft localisation of the tumor was found in 8 cases and in 11 patients the metastatic foci were found in proximnal diaphysis. In patients with proximal diaphysis localisation of the tumor the partial resection with subsequent joint exchange procedure was made. The humeral shaft metastatic cancer changes were treated by the segmental resection with subsequent surgical cement filling or auto/allogenical bone grafting combined with intramedullary nail or AO/ASIF plate stabilisation. The average follow-up period was 8,5 months. Results. In patients after resection with shoulder joint alloplasty according to the Enneking test a very good result was found in 7 and very good in 4 cases. In patients with femoral shaft metastatic tumor locaslisation, 6 good and 2 fair results were found. In 1 patient after 2 months rehabilitation a reoperation was needed due to the mechanical destabilisation. The best results were found in patients after intramedullary nailing.An acute soft tissue inflamation requiering surgical treatment was found in 1 patient after shoulder joint replacement. Conclusions. After clinical analysis of the material we highly recomend the partial humeral bone resection with subsequent shoulder alloplasty in patients with proximal humeral diaphysis metastatic localisation. In cases with shaft localisation a better results were

  2. Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur

    OpenAIRE

    Shyam Kumar, A. J.; Parmar, V.; Bankart, J.; Williams, S. C.; Harper, W. M.

    2006-01-01

    This study compared the accuracy of lag screw placement between extracapsular femoral fractures fixed with sliding hip screw plate systems and those fixed with cephalocondylic nails. It involved 75 retrospective radiographs of fractures fixed with either a cephalocondylic nail (32) or a sliding hip screw plate system (43). Postoperative anteroposterior and lateral radiographs of the hip were scanned using a digital X-ray scanner and measured using computer software. Measurements were conducte...

  3. A comparison of two fixation methods for femoral trochanteric fractures: a new generation intramedullary system vs sliding hip screw.

    Science.gov (United States)

    Carulli, Christian; Piacentini, Federico; Paoli, Tommaso; Civinini, Roberto; Innocenti, Massimo

    2017-01-01

    Trochanteric fractures are frequent and generally associated with bone fragility. There is still debate on the best fixation device to treat stable or rather stable trochanteric fractures: we report our clinical and radiological results of fixation with Proximal Femoral Nail "antirotation" (PFNa) in a population of patients compared to a control group treated by Sliding Hip Screw (SHS). A prospective study was conducted in 71 consecutive patients treated by PFNa (group A), and 69 by a SHS (group B), with a mean age of 81.6 and 83.4 years respectively. Short Form 12 was administered to check postoperative results, and the following parameters were evaluated: range of motion, evaluation of pain, gait ability, X-rays, and Tip Apex Distance Index. A minimum follow-up was conducted in 128 patients: 66 subjects belonging to the PFNa group and 62 to the DHS group. All patients in the group A were able to reach partial or full weight-bearing on the operated leg before leaving the hospital. Forty-four patients (63.8%) of the group B were able to walk with partial weight-bearing before discharge. We recorded 17 complications with a final overall percentage of 17.2% on the overall study population with one single case of failure in both the two groups. A statistical significance (ptrochanteric fractures as well as DHS. The light superiority of PFNa may be principally related to its mechanical advantages.

  4. Hydrocephalus: a rare initial manifestation of sporadic intramedullary hemangioblastoma : Intramedullary hemangioblastoma presenting as hydrocephalus.

    Science.gov (United States)

    Morais, Barbara Albuquerque; Cardeal, Daniel Dante; Ribeiro E Ribeiro, Renan; Frassetto, Fernando Pereira; Andrade, Fernanda Goncalves; Matushita, Hamilton; Teixeira, Manoel Jacobsen

    2017-08-01

    Intramedullary hemangioblastomas are rare benign vascular tumors, infrequent in pediatric patients. Clinical symptoms vary according to the age of presentation, tumor size, location, and concomitant syringomyelia. This is the second reported case of hemangioblastoma presenting with acute hydrocephalus. A 3-month-old infant with acute hydrocephalus was asymptomatic after a ventriculoperitoneal shunt was placed. She returned 3 months later with irritability, acute paraplegia, and respiratory distress. Magnetic resonance imaging (MRI) showed an intramedullary T8-T9 tumor with syringomyelia. She underwent surgical resection with good results during the 6-month follow-up. Intramedullary tumors may present as hydrocephalus and other nonspecific symptoms, with invariably delayed diagnosis in children, but must be considered in suspicious cases.

  5. The effect of lower limb rehabilitation gymnastics on postoperative rehabilitation in elderly patients with femoral shaft fracture: A retrospective case-control study.

    Science.gov (United States)

    Yang, Si-Dong; Ning, Sheng-Hua; Zhang, Li-Hong; Zhang, Ying-Ze; Ding, Wen-Yuan; Yang, Da-Long

    2016-08-01

    The purpose of this study was to explore the effect of lower limb rehabilitation gymnastics on postoperative rehabilitation in elderly patients with femoral shaft fracture after undergoing intramedullary nail fixation surgery.We collected medical records of elderly patients aged ≥ 60 years with femoral shaft fracture between 03/2010 and 03/2015 in Longyao County Hospital. Totally, 160 patients were identified and divided into the intervention group (n = 80) and the control group (n = 80). During the postoperative period, the intervention group received lower limb rehabilitation gymnastics treatment for 3 months, but the control group did not. All patients were routinely asked to return hospital for a check in the 1st postoperative week, as well as the 2nd week, the 1st month, and the 3rd month, after surgery. The clinical rehabilitation effect was evaluated by checking lower limb action ability, detecting the lower limb deep venous thrombosis (DVT), scoring muscle strength of quadriceps and visual analog scale (VAS) score, and performing satisfaction survey.At the 1st week and 2nd week after surgery, the clinical rehabilitation effect in the intervention group was better regarding lower limb action ability, lower limb DVT, muscle strength of quadriceps, VAS score, and patient satisfaction, as compared with the control group. However, there was no significant difference at the 1st month and the 3rd month after surgery when comparing the intervention group to the control group.In the early postoperative stage, lower limb rehabilitation gymnastics can effectively improve the recovery of lower limb function, beneficial to reducing postoperative complications such as lower limb DVT and muscle atrophy, and increasing patient satisfaction rate.

  6. Immediate versus delayed intramedullary nailing for open fractures of the tibial shaft: a multivariate analysis of factors affecting deep infection and fracture healing.

    Science.gov (United States)

    Yokoyama, Kazuhiko; Itoman, Moritoshi; Uchino, Masataka; Fukushima, Kensuke; Nitta, Hiroshi; Kojima, Yoshiaki

    2008-10-01

    The purpose of this study was to evaluate contributing factors affecting deep infection and fracture healing of open tibia fractures treated with locked intramedullary nailing (IMN) by multivariate analysis. We examined 99 open tibial fractures (98 patients) treated with immediate or delayed locked IMN in static fashion from 1991 to 2002. Multivariate analyses following univariate analyses were derived to determine predictors of deep infection, nonunion, and healing time to union. The following predictive variables of deep infection were selected for analysis: age, sex, Gustilo type, fracture grade by AO type, fracture location, timing or method of IMN, reamed or unreamed nailing, debridement time (6 h), method of soft-tissue management, skin closure time (1 week), existence of polytrauma (ISS or =18), existence of floating knee injury, and existence of superficial/pin site infection. The predictive variables of nonunion selected for analysis was the same as those for deep infection, with the addition of deep infection for exchange of pin site infection. The predictive variables of union time selected for analysis was the same as those for nonunion, excluding of location, debridement time, and existence of floating knee and superficial infection. Six (6.1%; type II Gustilo n=1, type IIIB Gustilo n=5) of the 99 open tibial fractures developed deep infections. Multivariate analysis revealed that timing or method of IMN, debridement time, method of soft-tissue management, and existence of superficial or pin site infection significantly correlated with the occurrence of deep infection (Prate in type IIIB + IIIC was significantly higher than those in type I + II and IIIA (P = 0.016). Nonunion occurred in 17 fractures (20.3%, 17/84). Multivariate analysis revealed that Gustilo type, skin closure time, and existence of deep infection significantly correlated with occurrence of nonunion (P < 0.05). Gustilo type and existence of deep infection were significantly correlated

  7. A six-year retrospective analysis of cut-out risk predictors in cephalomedullary nailing for pertrochanteric fractures: Can the tip-apex distance (TAD) still be considered the best parameter?

    Science.gov (United States)

    Caruso, G; Bonomo, M; Valpiani, G; Salvatori, G; Gildone, A; Lorusso, V; Massari, L

    2017-08-01

    Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years. A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)). The incidence of cut-out across the sample was 5.6%, with a higher incidence in female patients. A significantly higher risk of this complication was correlated with lag-screw tip positioning in the upper part of the femoral head in the anteroposterior radiological view, posterior in the latero-lateral radiological view, and in the Cleveland peripheral zones. The tip-apex distance and the calcar-referenced tip-apex distance were found to be highly significant predictors of the risk of cut-out at cut-offs of 30.7 mm and 37.3 mm, respectively, but the former appeared more reliable than the latter in predicting the occurrence of this complication. The tip-apex distance remains the most accurate predictor of cut-out, which is significantly greater above a cut-off of 30.7 mm. Cite this article: G. Caruso, M. Bonomo, G. Valpiani, G. Salvatori, A. Gildone, V. Lorusso, L. Massari. A six-year retrospective analysis of cut-out risk predictors in cephalomedullary nailing for pertrochanteric fractures: Can the tip-apex distance

  8. A Case of Femoral Fracture in Klippel Trenaunay Syndrome

    Directory of Open Access Journals (Sweden)

    Sam Nahas

    2014-01-01

    Full Text Available We present a case of Klippel Trenaunay syndrome (KTS who presented with severe bilateral knee osteoarthritis (OA. Preoperative planning was commenced for a total knee replacement (TKR. Whilst on the waiting list the patient suffered a fall and sustained a complete femoral diaphysis fracture. Conservative management in the form of skin traction was initially chosen as significant extra- and intramedullary vascular malformations posed an increased risk of perioperative bleeding. This failed to progress to union, and so open reduction and internal fixation was performed. This subsequently resulted in on-going delayed union, which was subsequently managed with low intensity pulsed ultrasound (LIPUS, otherwise known as Exogen (Bioventus. exogen. Secondary exogen, 2012. There are only two previous documented cases of femoral fracture in KTS. This is the first report of a patient with this rare syndrome receiving this treatment. We discuss the management of fracture in this challenging group of patients.

  9. Treatment of trochanteric fractures with the gamma3 nail - methodology and early results of a prospective consecutive monitored clinical case series.

    Science.gov (United States)

    A C, Unger; E, Wilde; B, Kienast; C, Jürgens; A P, Schulz

    2014-01-01

    There is only sparse data on clinical results and complications of the third-generation Gamma nailing system (Gamma3, Stryker). Therefore, we started a large multi-centre case series in 2008. The aim of this paper is to present the study design and early results of a single arm of a prospective, consecutive, monitored, post-market follow-up evaluation of Gamma3 nails. From September 2009 to January 2012, 154 consecutive patients with an average age of 80 ± 1.43 years (50-99 years) and a trochanteric femoral fracture were included in the local arm of the trial. All patients that fulfilled the inclusion criteria were treated with a Gamma3 nail. Preoperative variables included age, gender, fracture classification, walking ability (Merle d'Aubigné score), daily activity level (retrospective Zuckerman score), ASA rating of operative risk, waiting time for operation, use of walker or crutches and body mass index (BMI). Skin-to-skin time, fluoroscopy time, blood loss, intraoperative complications and device information were recorded for each patient. Follow-up postoperative assessment was undertaken at 4, 12 and 24 months. Hip range of motion, pain around the hip and the tight, walking ability (Merle d'Aubigné score, Sahlgrenska mobility score) and management of daily life (Zuckerman score) were used to evaluate the outcome. The descriptive data of age, gender, BMI, ASA classification, fracture type and skin-to-skin time is similar to other studies. Median fluoroscopy time was 62 seconds (range: 4-225 seconds) and significantly shorter in closed reductions. No intraoperative implant-related complication was recorded. A cut-out of the leg-screw during assessment period occurred in 2.6% patients (n = 4). At the 12-month assessment two (1.8%) non-unions were identified and two patients (1.8%) had broken the femoral shaft below the 180 mm nail after a fall. Analysis of the scores showed significantly declined mobility and activity in daily life four months after operation

  10. Intramedullary fixation of proximal humerus fractures: do locking bolts endanger the axillary nerve or the ascending branch of the anterior circumflex artery? A cadaveric study

    Directory of Open Access Journals (Sweden)

    Sermon An

    2008-12-01

    Full Text Available Abstract Background Proximal humerus fractures are one of the most common fractures. Intramedullary locked nailing is becoming a popular alternative treatment, especially for easier fracture patterns. Although axillary nerve injury has been reported, no study has compared the safety of the proximal locking options relative to the axillary nerve and the ascending branch of the anterior circumflex artery. Method Six different commercially available proximal humeral nails were implanted in 30 shoulders of 18 cadavers. After fluoroscopically guided implantation the shoulders were carefully dissected and the distance between the locking screws, the axillary nerve and the ascending branch of the anterior circumflex artery was measured. Results The course of the axillary nerve varies. A mean distance of 55.8 mm (SD = 5.3 between the lateral edge of the acromions and the axillary nerve at the middle of the humerus in a neutrally rotated position was observed. The minimum distance was 43.4 mm, the maximum 63.9 mm. Bent nails with oblique head interlocking bolts appeared to be the most dangerous in relation to the axillary nerve. The two designs featuring such a bend and oblique bolt showed a mean distance of the locking screw to the axillary nerve of 1 mm and 2.7 mm respectively Sirus (Zimmer® and (Stryker® T2 PHN (Proximal Humeral Nail. Regarding the ascending branch of the anterior circumflex artery, there was no difference between the nails which have an anteroposterior locking option. Conclusion It is of great importance for surgeons treating proximal humerus fractures to understand the relative risk of any procedure they perform. Since the designs of different nailing systems risk damaging the axillary nerve and ascending branch, blunt dissection, the use of protection sleeves during drilling and screw insertion, and individual risk evaluation prior to the use of a proximal humeral nail are advocated.

  11. Comparative study of the second and third generation of gamma nail for trochanteric fractures: review of 218 cases.

    Science.gov (United States)

    Mingo-Robinet, Juan; Torres-Torres, Miguel; Martínez-Cervell, Carmen; Alonso Del Olmo, Juan Antonio; Rivas Laso, Jose A; Aguado-Hernández, Hector; Burón-Alvarez, Isidro

    2015-03-01

    The aim of this study was to compare the complications of the trochanteric gamma nail (TGN) and the Gamma3 Nail (G3), focusing on cutout failure. Retrospective comparative cohort analysis. Level II Teaching Trauma Center academic trauma center. Two hundred eighteen trochanteric fractures with a mean follow-up of 15 months were included in the study. They were treated either with the TGN or the G3 between January 2005 and December 2010. Bivariate, stratified, and logistic regression analysis was conducted to determine the association between cutout and the independent variables. Proximal anterograde nailing with either the TGN or the G3. Patient age, sex, type of intramedullary device, stability fracture pattern, tip-apex distance (TAD), distraction at the fracture site, cervical angle, and cutout. The relative risk (RR) of cutout was 4.71 times higher in the group treated with G3 (P fractures compared with stable fractures was 3.07 (1.01-9.35). In unstable fractures, the RR of cutout was 8.78 times higher in patients with G3 (P 25 mm (P = 0.4). We have not found any relationship between cutout rate and TAD. Only the fracture pattern and the type of implant have shown to be associated with cutout risk. In our study, Gamma3 Nail has higher cutout rates than TGN in unstable fractures. Therapeutic level III. See Instructions for Authors for a complete description of levels of evidence.

  12. Elastic nailing of tibia shaft fractures in young children up to 10 years of age.

    Science.gov (United States)

    Heo, Jeong; Oh, Chang-Wug; Park, Kyeong-Hyeon; Kim, Joon-Woo; Kim, Hee-June; Lee, Jong-Chul; Park, Il-Hyung

    2016-04-01

    Although tibia shaft fractures in children usually have satisfactory results after closed reduction and casting, there are several surgical indications, including associated fractures and soft tissue injuries such as open fractures. Titanium elastic nails (TENs) are often used for pediatric tibia fractures, and have the advantage of preserving the open physis. However, complications such as delayed union or nonunion are not uncommon in older children or open fractures. In the present study, we evaluated children up to 10 years of age with closed or open tibial shaft fractures treated with elastic nailing technique. A total of 16 tibia shaft fractures treated by elastic nailing from 2001 to 2013 were reviewed. The mean patient age at operation was 7 years (range: 5-10 years). Thirteen of 16 cases were open fractures (grade I: 4, grade II: 6, grade IIIA: 3 cases); the other cases had associated fractures that necessitated operative treatments. Closed, antegrade intramedullary nailing was used to insert two nails through the proximal tibial metaphysis. All patients were followed up for at least one year after the injury. Outcomes were evaluated using modified Flynn's criteria, including union, alignment, leg length discrepancies, and complications. All fractures achieved union a mean of 16.1 weeks after surgery (range: 11-26 weeks). No patient reported knee pain or experienced any loss of knee or ankle motion. There was a case of superficial infection in a patient with grade III open fracture. Three patients reported soft tissue discomfort due to prominent TEN tips at the proximal insertion site, which required cutting the tip before union or removing the nail after union. At the last follow-up, there were no angular or rotational deformities over 10° in either the sagittal or coronal planes. With the exception of one case with an overgrowth of 15 mm, no patient showed shortening or overgrowth exceeding 10mm. Among final outcomes, 15 were excellent and 1 was

  13. Bilateral simultaneous femoral neck and shafts fractures - a case report.

    Science.gov (United States)

    Sadeghifar, Amirreza; Saied, Alireza

    2014-10-01

    Simultaneous fractures of the femoral neck and shaft are not common injuries, though they cannot be considered rare. Herein, we report our experience with a patient with bilateral occurance of this injury. Up to the best of our knowkedge this is the first case reported in literature in which correct diagnosis was made initially. Both femurs were fixed using broad 4.5 mm dynamic compression plate and both necks were fixed using 6.5 mm cannulated screws. Femur fixation on one side was converted to retrograde nailing because of plate failure. Both neck fractures healed uneventfully. In spite of rarity of concomitant fractures of femoral neck and shaft, this injury must be approached carefully demanding especial attention and careful device selection.

  14. The effect of canal fill on paediatric femur fractures treated with titanium elastic nails.

    Science.gov (United States)

    Nielsen, E; Bonsu, N; Andras, L M; Goldstein, R Y

    2018-02-01

    Traditional teaching for fixation of paediatric femur fractures recommends 80% nail diameter/medullary canal diameter ratio (ND/MCD) for successful maintenance of reduction. Prior studies have investigated this with stainless steel Enders nails. Our aim was to assess the impact of ND/MCD on maintenance of reduction and malunion rates in paediatric femur fractures treated with flexible intramedullary nails (FINs). Retrospective data was collected on all paediatric patients treated with FINs for diaphyseal femur fractures at a single tertiary care institution over a ten-year period. Patients with co-morbidities affecting bone quality were excluded. Patients were subdivided into groups based on ND/MCD. A total of 66 patients met inclusion criteria. Mean ND/MCD was 76.3% (32.9% to 98.8%, SD 14.3). In all, 50% (n = 33/66) of patients had > 80% ND/MCD, and only 13.6% (n = 9/66) of patients had less than 60% ND/MCD. When controlling for fracture stability, ND/MCD had no correlation with mean shortening (p = 0.07) There was no correlation between ND/MCD and angulation in the sagittal (p = 0.96) or coronal plane (p = 0.20). Three patients fit malunion criteria. ND/MCD for these patients were 40%, 67% and 79%. There was no correlation between ND/MCD and shortening or malangulation. The majority of patients in this series with less than 80% fill with FIN healed within acceptable parameters. III.

  15. Update on nail cosmetics.

    Science.gov (United States)

    Jefferson, Julie; Rich, Phoebe

    2012-01-01

    Nail cosmetics are used by millions of people worldwide who desire smooth, lustrous nails. The nail cosmetic industry continues to expand to meet increasing consumer demand. In 2011 alone, consumers spent $6.6 billion on nail salon services. Although nail cosmetics are relatively safe, poor application techniques can promote disease, deformity, and allergic and irritant contact dermatitis. The foundation for managing nail cosmetic problems is prevention through education. Familiarity with the procedures and materials used in the nail cosmetic industry is necessary in order to recommend safe nail care strategies. © 2012 Wiley Periodicals, Inc.

  16. Which factor is most important for occurrence of cutout complications in patients treated with proximal femoral nail antirotation? Retrospective analysis of 298 patients.

    Science.gov (United States)

    Turgut, Ali; Kalenderer, Önder; Karapınar, Levent; Kumbaracı, Mert; Akkan, Hasan Ali; Ağuş, Haluk

    2016-05-01

    Mechanical complications, such as cut-out of the head-neck fixation device, are the most common causes of morbidity after trochanteric femur fracture treatment. The causes of cut-out complications are well defined in patients who are treated with sliding hip screws and biaxial cephalomedullary nails but there are few reports about the patients who are treated with proximal femoral nail antirotation. The purpose of this study was to evaluate the most important factor about occurance of cutout complication and also to evaluate the risks of the combination of each possible factors. Overally 298 patients were enrolled in the study. Medical records were reviewed for patients' age, fracture type, gender, anesthesia type and occurance of cut-out complication. Postoperatively taken radiographs were reviewed for tip-apex distance, obtained collo-diaphyseal angle, the quadrant of the helical blade and Ikuta reduction subgroup. The most important factor (s) and also predicted probability of cut-out complication was calculated for each combination of factors. Cut-out complication was observed in 14 patients (4.7 %). The most important factor about occurrence of the cut-out complication was found as varus reduction (p: 0.01), the second important factor was found as implantation of the helical blade in the improper quadrant (p: 0.02). Tip-apex distance was found as third important factor (p: 0.10). The predicted probability of cut-out complication was calculated as 45.6 % when whole of the four surgeon dependent factors were improperly obtained. Althought obtaining proper tip-apex distance is important to prevent cutout complication in these fractures, if the fracture is not reduced in varus position and helical blade is inserted in the proper quadrant, possibility of cut-out complication is very low even in the patients with high tip-apex distance.

  17. Treatment outcomes of intertrochanteric femur fractures treated with DLT™ nail

    Directory of Open Access Journals (Sweden)

    Mehmet Arıcan

    2015-12-01

    Full Text Available Objective: Intramedullary nails frequently use in proximal femur fractures. In this study, 49 patients with intertrochanteric fractures were evaluated clinical and radiological results treated with dyna locking trochanteric (DLT™ nail retrospectively. Methods: Twenty-two (44.9% patients were male and 27 (55.1% patients were female. Mean age was 74.29±1.98 (28-99 years and Followed up for a mean of 14.35±3.43 (9-24 months. Thirty-seven (75.6% of the fractures resulted from simple falls while 6 (12.2% caused from traffic accidents and 6 (12.2% fall down from height. There were 24 (49.0% left and 25 (51.0% right lower extremities fractured. According to Orthopaedic Trauma Association classification system; 21 (42.9%, 21 (42.9% and 7 (14.2% fractures were classified as 31A1, 31A2, and 31A3 respectively. One (2.0% patient had claviculae fracture, 3 (6.1% patients had radius distal fracture and 1 (2.0% patient had total knee arthroplasty. After surgery, X-ray was used for radiological results and functional outcomes were evaluated according to the Harris hip scoring system. Results: The average waiting time for the surgery was 2.02±0.18 (1-7 days and hospitalization time was 6.23±0.29 (4-15 days. Mean fracture healing time was 11.74±1.82 (8-15 weeks. Three patients had screw cut-out in the follow-up time and performed hemiarthroplasty. The average Harris hip score was 88.02±1.21 (42-97 points and included 29 (59.2% excellent cases, 17 (34.7% good and 3 (6.1% poor. Conclusion: DLT ™ nail is a safe and successful method because of low complication rates, and capability of detection.

  18. Precise placement of lag screws in operative treatment of trochanteric femoral fractures with a new guide system.

    Science.gov (United States)

    Poyanli, Oguz S; Soylemez, Salih; Ozkut, Afsar T; Uygur, Esat; Kemah, Bahattin; Unal, Omer K

    2015-11-01

    We assessed the accuracy of a new guide system that we developed to place lag screws in the proper position with the minimum number of attempts for operative treatment of trochanteric femoral fractures. A total of 55 consecutive trochanteric femoral fractures were treated with a cephalomedullary nail. The first 27 consecutive patients were treated with the standard operation (group A), while the new guide system was used in the last 28 consecutive patients (group B). The numbers of attempts to place K wires and the duration of surgery were noted. Accuracy of lag screw placement was evaluated by measuring the angle of deviation from the central axis of the femoral head. Deviation values ranged from -11̊ to +15̊ for the 27 cases in group A, with a median absolute deviation of 8̊±6̊. That in the 28 cases after the introduction of the new guide system (group B) ranged from -5̊ to +6̊, with a median absolute deviation of 0.5̊±3̊ (Pfractures. The present study indicated that this new guide system and nail facilitate accurate placement of lag screws in the appropriate position with the minimum number of attempts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. SUPRAPATELLAR VERSUS INFRAPATELLAR TIBIAL NAIL INSERTION- A PROSPECTIVE, RANDOMISED CONTROL PILOT STUDY

    Directory of Open Access Journals (Sweden)

    Sreekumar K

    2017-06-01

    Full Text Available BACKGROUND The standard for treating tibial shaft fractures are by intramedullary nails currently. After the procedure, one of the most frequent complication is knee pain, after consolidation even more chronically. Chronic knee pain can affect more than 50% of the cases, which was said by most authors. Alternative routes of inserting the nail is used, which includes by means of lateral patellar paratendon, medial patellar paratendon or transtendon to avoid the symptom. The aim of the study is to study the clinical and functional outcomes of suprapatellar versus infrapatellar tibial nail insertion. MATERIALS AND METHODS This is a prospective study, which was done from January 2014 to February 2015 and 50 patients who were skeletally mature were selected and randomised into IP and SP nail insertion groups. They were also given informed consent and only after they agreed, they were taken into the study. The technique of nail insertion was revealed to both the surgeon and the patient at that time. Exclusion Criteria- Pregnant women, patients with intra-articular involvement, periprosthetic fractures, nonunions, ipsilateral injuries, previous knee injuries, history of gout, rheumatoid, osteoarthritis, spinal injury and incarceration. SP insertion was performed percutaneously with the help of a special cannula system. RESULTS A total of 50 patients were selected in this study. 31 SP and 19 IP. 10 SP and 2 IP did not show up for follow up examinations, so only 38 patients were present for 12 months. At last, there were 21 SP and 17 IP patients. The time from when the index procedure was done to follow up was 14.6 months, i.e. it ranged from 12-28 months. 12 were males and 9 were females with suprapatellar, 9 were males and 8 were females in infrapatellar. Average age of suprapatellar was 42 and that of infrapatellar was 44. Open fractures were 5 and closed fractures were 33. VAS score was 0.78 in suprapatellar and 1.87 in infrapatellar. Data analysis

  20. Intramedullary capillary haemangioma.

    LENUS (Irish Health Repository)

    Kelleher, T

    2012-02-03

    Intramedullary capillary haemangioma is extremely rare and only four cases have been previously reported. We describe a further case, outlining the clinical, radiological, surgical and pathological features.

  1. Green Nail Syndrome

    Science.gov (United States)

    ... nail is detached from the nail bed, the waterproof seal formed by the skin on the nail ... should also be noted that wearing tight-fitting shoes for a prolonged time, especially while exercising, is ...

  2. Fixator-Assisted Lengthening and Deformity Correction Over an Intramedullary Nail in a Patient with Achondroplasia

    Directory of Open Access Journals (Sweden)

    Erdal Uzun

    2016-05-01

    Full Text Available Achondroplasia is the most frequently encountered form of nonlethal skeletal dysplasia and a type of rhizomelic dwarfism. It results in considerable physical and psychologic handicaps owing to the disproportionate stature of the body and difficulty in performing routine activities of daily living. They also have major musculoskeletal problems including symptomatic malalignment of the lower limbs. Limb lengthening has been used in patients with achondroplasia by different techniques (Intramedullar nailing, monolateral or circular external fixator. We report our treatment of a patient 17 years of age with achondroplasia for bilateral lower limb length discrepancy and bilateral tibial varus deformity.

  3. Advanced nail surgery

    Directory of Open Access Journals (Sweden)

    Eckart Haneke

    2011-01-01

    Full Text Available Six techniques not yet widely known or used in the dermatologic surgery of the nails are briefly described. Small-to-medium-sized tumours of the proximal nail fold (PNF can be excised and the defect repaired with advancement or rotation flaps. A superficial biopsy technique of the matrix for the diagnosis of longitudinal brown streaks in the nail, which allows rapid histological diagnosis of the melanocyte focus to be performed, is described here. Because the excision is very shallow and leaves the morphogenetic connective tissue of the matrix intact, the defect heals without scarring. Laterally positioned nail tumours can be excised in the manner of a wide lateral longitudinal nail biopsy. The defect repair is performed with a bipedicled flap from the lateral aspect of the distal phalanx. Malignant tumours of the nail organ often require its complete ablation. These defects can be covered by a full-thickness skin graft, reversed dermal graft, or cross-finger flap. The surgical correction of a split nail is often difficult. The cicatricial tissue of the matrix and PNF have to be excised and the re-attachment of these wounds prevented. The matrix defect has to be excised and sutured or covered with a free matrix graft taken either from the neighbouring area or from the big toe nail.

  4. Yellow nail syndrome, pincer nails, colon cancer and polyps in a 76 year-old-woman

    Directory of Open Access Journals (Sweden)

    Vitorino Modesto dos Santos

    2015-11-01

    Full Text Available The yellow nail syndrome is a scarcely described condition characterized by dystrophic yellowish nails, respiratory disturbances and lymphedema; while the pincer nail deformity is characterized by thickening and excessive transverse curvature of the nail plate. The objective of this case study is to report a 76-year-old Japanese descent woman with yellow nail syndrome and pincer nails, intestinal polyps, and sigmoid colon adenocarcinoma. Both the yellow nail syndrome and pincer nails may develop in association with malignancies, either by chance or by some etiopathogenic mechanism not well-known.

  5. Interventions for nail psoriasis

    NARCIS (Netherlands)

    de Vries, Anna Christa Q.; Bogaards, Nathalie A.; Hooft, Lotty; Velema, Marieke; Pasch, Marcel; Lebwohl, Mark; Spuls, Phyllis I.

    2013-01-01

    Psoriasis is a common skin disease that can also involve the nails. All parts of the nail and surrounding structures can become affected. The incidence of nail involvement increases with duration of psoriasis. Although it is difficult to treat psoriatic nails, the condition may respond to therapy.

  6. Interventions for nail psoriasis

    NARCIS (Netherlands)

    Vries, A.C. de; Bogaards, N.A.; Hooft, L.; Velema, M.; Pasch, M.C.; Lebwohl, M.; Spuls, P.I.

    2013-01-01

    BACKGROUND: Psoriasis is a common skin disease that can also involve the nails. All parts of the nail and surrounding structures can become affected. The incidence of nail involvement increases with duration of psoriasis. Although it is difficult to treat psoriatic nails, the condition may respond

  7. Tibiocalcaneal Arthrodesis With a Porous Tantalum Spacer and Locked Intramedullary Nail for Post-Traumatic Global Avascular Necrosis of the Talus.

    Science.gov (United States)

    Cohen, Michael M; Kazak, Marat

    2015-01-01

    Global avascular necrosis of the talus is a devastating complication that usually occurs as a result of a post-traumatic or metabolic etiology. When conservative options fail, tibiocalcaneal arthrodesis is generally indicated in conjunction with massive bone grafting to maintain the functional length of the extremity. Several bone grafting options are available, including the use of a freeze-dried or fresh-frozen femoral head allograft or autograft obtained from the iliac crest or fibula, all of which pose their own inherent risks. The noted complications with massive bone grafting techniques have included graft collapse, infection, immune response, donor site morbidity, and nonunion. In an effort to avoid many of these complications, we present a case report involving post-traumatic talar avascular necrosis in a 59-year-old male who was successfully treated with the use of a porous tantalum spacer, an autogenic morselized fibular bone graft, and 30 mL of bone marrow aspirate in conjunction with a retrograde tibiocalcaneal nail. Porous tantalum is an attractive substitute for bone grafting because of its structural integrity, biocompatibility, avoidance of donor site complications, and lack of an immune response. The successful use of porous tantalum has been well-documented in hip and knee surgery. We present a practical surgical approach to tibiotalocalcaneal arthrodesis with a large segmental deficit. To our knowledge, this is the first published report describing an alternative surgical technique to address global avascular necrosis of the talus that could have additional applications in salvaging the ankle with a large bone deficiency. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Comparative study of bridge plate associated to the intramedullary pin and the dynamic compression plate on the experimental osteotomy fixation of femoral in rabbits (Oryctolagus cuniculus). Clinical, radiographic, histological and scintigraphy analyses

    International Nuclear Information System (INIS)

    Borges, Natalie Ferreira

    2011-01-01

    The objectives were to benchmark and monitor the fracture healing of femoral osteotomy in rabbits after fixation with dynamic compression plate and bridge plate associated with intramedullary pin. Were used 14 New Zealand rabbits, four months old with mean weight of 3.5 pounds, from the Experimental Farm Professor Helio Barbosa of the Veterinary School of Minas Gerais Federal Univ. (UFMG). The animals were randomly divided into two groups (I and II). All rabbits underwent osteotomy across the middle third of right femur. In the group I was made to fix the osteotomy with the bridge plate (BP) associated with intramedullary pin, introduced the technique of minimal invasion. In group II, we used dynamic compression plate (DCP) via the conventional approach. Both groups were evaluated clinical, radiographic, histologic and scintigraphic findings. Clinical assessments were performed weekly until the 12 th postoperative week and radiographic examinations were performed before, immediately after, at 15, 30, 45, 60 and 90 days. The bone scintigraphy were performed before and at 20, 50 and 90 days after surgery to monitor the bone metabolism qualitatively and quantitatively. Observed perfusion and bone healing process. After 90 days of study, there was histopathologic evaluation of the osteotomized area and the insertion of screws. In the region of the osteotomy was observed predominance of trabecular bone in group I and group II, the predominance of bone osteons, compatible with the original bone. On insertion of the screws did not differ between groups and there was cortical discontinuity, little necrosis and local hemorrhage. The two types of fixation have led to consolidation within the scheduled period, maturing in early fixation with DCP fixation compared with BP. Scintigraphy demonstrated by the indices of activity and image characteristics, the process of bone healing was significantly greater in animals undergoing early fixation with DCP. (author)

  9. The healing stages of an intramedullary implanted tibia: A stress strain comparative analysis of the calcification process

    Science.gov (United States)

    Filardi, Vincenzo

    2015-01-01

    Aims The extended usage of unreamed tibial nailing resulted in reports of an increased rate of complications, especially for the distal portion of the tibia. Unreamed nailing favours biology at the expense of the achievable mechanical stability, it is therefore of interest to define the limits of the clinical indications for this method. Extra-articular fractures of the distal tibial metaphysis, meta-diaphyseal junction, and adjacent diaphysis are distinct in their management from impaction derived ‘‘pilon’’ type fractures and mid-diaphyseal fractures. The goals of this work were to gain a thorough understanding of the load-sharing mechanism between unreamed nail and bones in a fractured tibia. With this purpose a complete model of the human leg was realised, simulating a mid-diaphyseal fracture, classified as A2 type 1, according to the AO classification. The analysis of the entire chain allows to have a complete picture of the stress distribution and of the most stressed bones and soft tissues, but, more importantly can overcome problems connected with boundary conditions imposed at single bony components. Methods Model consists of six bony structures: pelvis, femur, patella, fibula, tibia, and a simplified lump of the feet, configured in a standing up position. Their articular cartilage layers, were simulated by 3D membranes of opportune stiffness connecting the different segments. Moreover an unreamed intra-medullary nail Expert Tibial Nail (DePuy Synthes®) stabilized the fractured tibia. A load of 700 N has been applied at the top of pelvis and a part the feet, at the tip, was rigidly fixed. Five different contact interfaces have been imposed at the different bony surfaces in contact. Results Three different conditions were analysed: the initially healthy tibia, the A2 type 1 fractured tibia with the Expert tibial nail implanted, and the follow up stage after complete healing of tibia. Non-linear finite element analysis of the models were performed

  10. Nail-gun injury of the cervical spine: simple technique for removal of a barbed nail.

    Science.gov (United States)

    Nathoo, Narendra; Sarkar, Atom; Varma, Gandhi; Mendel, Ehud

    2011-07-01

    Although nail-gun injuries are a common form of penetrating low-velocity injury, impalement with barbed nails has been underreported to date. Barbed nails are designed to resist dislodgment once embedded, and any attempt at removal may splay open the barbs along the path of entry, with the potential for significant soft-tissue and neurovascular injury. A 25-year-old man sustained a nail impalement of the cervical spine from accidental discharge of a nail gun. The patient was noted to be fully conscious with no neurological deficits. Cervical Zone 2 impalement was noted, with only the head of the nail visible. Angiography revealed the nail lying just anterior to the right vertebral artery (VA), with compression of the vessel. Preoperatively, analysis of a similar nail revealed that orientation of the head determined position of the barbs. A deep neck dissection was then performed to the lateral aspect of the C-3 body, using the nail as a guide. Prior to removal, the nail was turned 180° to change the position of the barbs, to prevent injury to the VA. Nail removal was uneventful. The authors present a simple technique for treatment of a nail-gun injury with a barbed nail. Prior to removal, radiographic analysis of the impaled nail must be performed to determine the presence of barbs. If possible, the surgeon should request a similar nail for analysis prior to surgery. Last, the treating surgeon must have knowledge of the barbs' position at all times during nail removal, to prevent damage to critical structures.

  11. Trauma to the nail complex

    Directory of Open Access Journals (Sweden)

    Jefferson Braga Silva

    2014-04-01

    Full Text Available OBJECTIVE: to analyze the results from surgical intervention to treat trauma of the nail complex.METHODS: we retrospectively reviewed a series of 94 consecutive patients with trauma of the nail complex who were treated between 2000 and 2009. In 42 patients, nail bed suturing was performed. In 27 patients, nail bed suturing was performed subsequent to osteosynthesis of the distal phalanx. In 15, immediate grafting was performed, and in 10, late-stage grafting of the nail bed. The growth, size and shape of the nail were evaluated in comparison with the contralateral finger. The results were obtained by summing scores and classifying them as good, fair or poor.RESULTS: the results were considered to be good particularly in the patients who underwent nail bed suturing or nail bed suturing with osteosynthesis of the distal phalanx. Patients who underwent immediate or late-stage nail grafting had poor results.CONCLUSION: trauma of the nail complex without loss of substance presented better results than did deferred treatment for reconstruction of the nail complex.

  12. A FUNCTIONAL EVALUATION STUDY OF DISTAL FEMORAL FRACTURES FIXED WITH DISTAL FEMORAL LOCKING PLATE

    Directory of Open Access Journals (Sweden)

    Manikumar C. J

    2017-04-01

    Full Text Available BACKGROUND Fractures of the distal femur present considerable challenges in management. Older patients especially women sustain fractures due to osteoporosis. Supracondylar fractures of femur have a bimodal distribution. They account for 6% of all femur fractures and 31% if hip fractures were excluded. Nearly, 50% of distal femur intra-articular fractures are open fractures. Before 1970, most supracondylar fractures were treated nonoperatively; however, difficulties were often encountered including persistent angulatory deformity, knee joint incongruity, loss of knee motion and delayed mobilisation. The trend of open reduction and internal fixation has become evident in recent years with good results being obtained with AO blade plate, dynamic condylar screw, intramedullary supracondylar nail and locking compression plate. Elderly patients and osteoporosis pose difficulty in treating intra-articular fractures of the lower end of femur. Loss of stable fixation is of great concern in these cases. Hence, locking compression plate use has an advantage in these patients. MATERIALS AND METHODS In this study, 20 patients with closed fracture of distal femur were studied. All the cases were treated at the Department of Orthopaedics, Rangaraya Medical College/Government General Hospital, Kakinada, Andhra Pradesh, between November 2013 and November 2015. The method used for fracture fixation was open reduction and internal fixation with distal femoral locking plate. The duration of follow up ranged from 3 months to 24 months. All the fractures in this series were posttraumatic. The patients were functionally evaluated with Neer’s scoring system. 1 RESULTS Twenty distal femoral fractures were treated with distal femoral locking plates. 15 patients were males and 5 patients were females. The median age was 47 years ranging from 28-70 years. 16 of the fractures were caused by road traffic accidents and 2 were due to fall, 2 were due to assault. 12 patients

  13. the anterior curve of the adult femur in a kenyan population and its ...

    African Journals Online (AJOL)

    Radius in centimeters. Radii of curvature of locally available femoral nails: The radii of curvature of the femoral nails ranged between 127cm and 200cm. The SIGN Nail, which is widely used now, however is a straight nail, but with a 90 proximal bend and a 1.50 distal bend to aid in insertion. The rest of the femoral nails had ...

  14. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... hair loss Injured skin Nail care Artificial nails Healthy nails Child nail care Manicure safety Nail biting Nail changes a dermatologist should examine Anti-aging skin care Kids’ zone Video library Find a ...

  15. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... Injured skin Nail care Artificial nails Healthy nails Child nail care Manicure safety Nail biting Nail changes ... c Explore the Academy Member resources Practice Tools Education Meetings & events Advocacy Public & patients Academy resources for: ...

  16. Nail involvement in psoriatic arthritis

    Directory of Open Access Journals (Sweden)

    Piotr Sobolewski

    2017-07-01

    Full Text Available Nail psoriasis is considered a significant psychological and social problem causing functional impairment in affected patients. Nail changes hamper their daily and occupational activities and contribute to a worse quality of life. Almost 50% of patients with psoriasis vulgaris and up to 80% of patients with psoriatic arthritis are afflicted with nail lesions. The important correlation between psoriatic arthritis and nail changes is well established – the presence of the latter is a strong predictor of the development of arthritis. There is a broad spectrum of nail dystrophies associated with psoriasis, ranging from the common pitting, subungual hyperkeratosis and loosening of the nail plate to less frequent discolouration and splinter haemorrhages. Some of these symptoms are also observed in other nail diseases, and further diagnostics should be performed. The assessment tools NAPSI (Nail Psoriasis Severity Index, mNAPSI (Modified Nail Psoriasis Severity Index, and PNSS (Psoriasis Nail Severity Score are most commonly used to grade the severity of nail involvement in psoriasis and enable the evaluation of therapy effectiveness. The treatment of nail psoriasis is a major clinical challenge. It should be adjusted to the extent of dermal, articular and ungual lesions. Systemic therapies of psoriasis, especially biological agents, are most likely to be effective in treating nail psoriasis. However, as their use is limited in scope and safety, topical therapy remains a mainstay, and the combination of corticosteroids and vitamin D3 analogues is considered to be most helpful.

  17. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... Hair care / hair loss Injured skin Nail care Artificial nails Healthy nails Child nail care Manicure safety Nail biting Nail changes a dermatologist should examine Anti-aging skin care Kids’ zone Video library Find a ...

  18. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... hair, and nail care Skin care Hair care / hair loss Injured skin Nail care Anti-aging skin care ... hair, and nail care Skin care Hair care / hair loss Injured skin Nail care Artificial nails Healthy nails ...

  19. Nail biopsy: A user's manual

    Directory of Open Access Journals (Sweden)

    Chander Grover

    2018-01-01

    Full Text Available Nail biopsy is a procedure not routinely resorted to; but when indicated, it is often the only clue left for diagnosis. At such times, it pays to be conversant with it. It is an investigation that not only provides etiologic, diagnostic, and prognostic information but also aids in understanding the pathogenesis of nail diseases. It can be of therapeutic value, especially with respect to nail tumors. This article compiles the procedural techniques for nail biopsy of various types and attempts to summarize the evidence available in the literature. The objective of nail biopsy is to clinch a precise diagnosis of nail pathology with a simple and safe surgical procedure, avoiding pain or permanent nail damage. Patient selection is of utmost importance, wherein, the patient does not have typical skin lesions, yields inadequate information on routine nail investigations, and has no peripheral vascular compromise. The patient needs to be explained about the risks associated, the expected functional handicap, the time required for regrowth, a possibility of permanent nail dystrophy, and a possibility of not achieving a diagnosis even after the biopsy. Techniques and types of various nail biopsies are being discussed in this article. The specimen could be collected as an excision biopsy, punch biopsy, shave biopsy, or longitudinal biopsy. The trick lies in choosing the appropriate area for biopsy. Various biopsy types discussed in this article include nail plate biopsy (easiest and least scarring; nail bed biopsy (elliptical excision or punch; nail matrix biopsy (elliptical excision, punch excision (≤3 mm or tangential/shave excision; and nail fold biopsy. Complications reported along with means to minimize them are also discussed.

  20. Contemporary management of subtrochanteric fractures.

    Science.gov (United States)

    Joglekar, Siddharth B; Lindvall, Eric M; Martirosian, Armen

    2015-01-01

    Cephalomedullary interlocking nails that allow for trochanteric entry and minimally invasive fixation have revolutionized the contemporary management of subtrochanteric fractures with improved union rates and decreased incidence of fixation failure. The most successful alternative to intramedullary fixation remains the angled blade plate. Despite biomechanical superiority of contemporary intramedullary implants to previous intramedullary devices, the importance of achieving and maintaining satisfactory fracture reduction prior to and during hardware insertion cannot be overemphasized. In comminuted and more challenging fractures, additional techniques, such as limited open reduction with clamps and/or cables, can allow for canal restoration and more anatomic reductions prior to and/or during nail insertion. Published by Elsevier Inc.

  1. COMPARATIVE STUDY BETWEEN PROXIMAL FEMORAL NAILING AND DYNAMIC HIP SCREW IN THE MANAGEMENT OF INTERTROCHANTERIC FRACTURES OF FEMUR

    Directory of Open Access Journals (Sweden)

    Penugonda Ravi Shankar

    2015-01-01

    Full Text Available AIMS AND OBJECTIVES : To determine the rate of union, complications, operative risks and functional outcomes in intertrochanteric fractures treated with DHS and PFN , To compare the results obtained and To compare the effectiveness of DHS and PFN in treatment of intertrochanteric fractures. RESULTS : In the present series of 24 cases of Intertrochanteric fractures were treated by proximal femoral nailing and dynamic hip screw, 12 cases in each. Out of 24 there were 13 male and 11 female. Minimum age was 36 years, maximum age 76 years with mean age of 59.25 years. Slip and fall accounted for 75% of cases. BOYD and GRIFFIN type II fracture accounted for 58.3% of cases. Mean duration of hospital stay was 26 days in both PFN and DHS groups. Length of incision was small 5 - 6cm in PFN group compared to 10 - 12cm in DHS group. Mean external blood loss 150ml in PFN group and 315 ml in DHS group. Mean time for full weight bearing was 11.5 weeks for PFN group and 14.3 weeks for DHS group. Radiological union was 12.3 weeks in PFN group and 15.5 weeks in DHS group. Good to excellent results were seen in 91.7% of cases in PFN group and 75% in DHS group. CONCLUSION : From the study, we consider PFN as better alternative to DHS in the treatment of intertrochanteric fractures but is technically difficult procedure and requires more expertise compared to DHS.As learning curve of PFN procedure is steep, with experience gained from each case operative time, radiation exposure and intraoperative complications can be reduced in each case of PFN

  2. Titanium exposure and yellow nail syndrome

    Directory of Open Access Journals (Sweden)

    Ali Ataya

    2015-01-01

    Full Text Available Yellow nail syndrome is a rare disease of unclear etiology. We describe a patient who develops yellow nail syndrome, with primary nail and sinus manifestations, shortly after amalgam dental implants. A study of the patient's nail shedding showed elevated nail titanium levels. The patient had her dental implants removed and had complete resolution of her sinus symptoms with no change in her nail findings. Since the patient's nail findings did not resolve we do not believe titanium exposure is a cause of her yellow nail syndrome but perhaps a possible relationship exists between titanium exposure and yellow nail syndrome that requires further studies.

  3. Postoperative malrotation of humeral shaft fracture after plating compared with intramedullary nailing.

    Science.gov (United States)

    Li, Ying; Wang, Cheng; Wang, Manyi; Huang, Lei; Huang, Qiang

    2011-09-01

    We supposed difference of rotation alignment of postoperative humeral shaft fracutres between open reduction and internal fixation (ORIF) and intramedullay nailing (IMN) could be identified and the difference might influence the involved shoulder. This study evaluated and compared the extent of malrotation and shoulder function after humeral shaft fractures treated operatively with IMN or ORIF. Fifty humeral shaft fractures were randomly allocated into 2 groups. Group I underwent antegrade IMN and group II underwent ORIF. Malrotation was measured postoperatively by computed tomography scan (CT). Fracture union and functional outcomes were recorded at 12 months. The final analysis comprised 45 patients. Group I had lower functional scores than group II (P shaft fracture. The study can provide baseline data for larger series and longer follow-up periods. Patients who underwent IMN had lower functional scores and a decreased range of motion postoperatively and also had a greater degree of malrotation than the ORIF group, which had none. The degree of malrotation correlated with a decreased range of motion and may possibly be a reason for degenerative arthritis at long-term follow-up. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  4. Portable x-ray fluorescence for the analysis of chromium in nail and nail clippings

    International Nuclear Information System (INIS)

    Fleming, David E.B.; Ware, Chris S.

    2017-01-01

    Assessment of chromium content in human nail or nail clippings could serve as an effective biomarker of chromium status. The feasibility of a new portable x-ray fluorescence (XRF) approach to chromium measurement was investigated through analysis of nail and nail clipping phantoms. Five measurements of 180 s (real time) duration were first performed on six whole nail phantoms having chromium concentrations of 0, 2, 5, 10, 15, and 20 µg/g. Using nail clippers, these phantoms were then converted to nail clippings, and assembled into different mass groups of 20, 40, 60, 80, and 100 mg for additional measurements. The amplitude of the chromium Kα characteristic x-ray energy peak was examined as a function of phantom concentration for all measurement conditions to create a series of calibration lines. The minimum detection limit (MDL) for chromium was also calculated for each case. The chromium MDL determined from the whole nail intact phantoms was 0.88±0.03 µg/g. For the clipping phantoms, the MDL ranged from 1.2 to 3.3 µg/g, depending on the mass group analyzed. For the 40 mg clipping group, the MDL was 1.2±0.1 µg/g, and higher mass collections did not improve upon this result. This MDL is comparable to chromium concentration levels seen in various studies involving human nail clippings. Further improvements to the portable XRF technique would be required to detect chromium levels expected from the lower end of a typical population. - Highlights: • Portable x-ray fluorescence (XRF) was explored as a technique to assess levels of chromium in human nails or nail clippings. • Results were found to depend on the mass of clipping sample provided. • Minimum detection limits for chromium were similar to concentration levels found in previous studies of human nail clippings.

  5. Diagnostic applications of nail clippings.

    Science.gov (United States)

    Stephen, Sasha; Tosti, Antonella; Rubin, Adam I

    2015-04-01

    "Nail clipping is a simple technique for diagnosis of several nail unit dermatoses. This article summarizes the practical approach, utility, and histologic findings of a nail clipping in evaluation of onychomycosis, nail unit psoriasis, onychomatricoma, subungual hematoma, melanonychia, and nail cosmetics, and the forensic applications of this easily obtained specimen. It reviews important considerations in optimizing specimen collection, processing methods, and efficacy of special stains in several clinical contexts. Readers will develop a greater understanding and ease of application of this indispensable procedure in assessing nail unit dermatoses." Copyright © 2015 Elsevier Inc. All rights reserved.

  6. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... biting your nails Nail biting typically begins in childhood and can continue through adulthood, and the side ... set of nails, such as your thumb nails, first. When that’s successful, eliminate your pinky nails, pointer ...

  7. Intramedullary disorders diagnosed by MRI. Clinical course in 23 cases

    International Nuclear Information System (INIS)

    Nagata, Kensei; Ohashi, Teruaki; Ishibashi, Kazumasa; Hirohashi, Akiyuki; Sato, Kimiaki

    1996-01-01

    We report the clinical course of 23 cases with intramedullary disorders diagnosed by MRI. Spinal vascular disease was the most common, and occurred in 11 cases, intramedullary tumor occurred in 6, and multiple sclerosis, myelitis, spinal edema each in 2. The characteristic MRI findings of the intramedullary disorders were spinal cord swelling on T1 weighted image and changes in the intensity on the T2 weighted image. Surgical treatment was performed in 5 of the 11 with spinal vascular disease and in 6 with an intra-medullary tumor. One patient with AV malformation underwent embolization of the spinal artery. The other 11 received conservative treatment. The period of follow-up ranged from 6 months to 9 years after onset. Complete recovery from symptoms was achieved in only 2 patients, some recovery was achieved in 8, no change in 10, and deterioration occurred in 3. In conclusion, it has become easy to diagnose intramedullary disorders by utilizing MRI. However, an accurate qualitative diagnosis is difficult except for spinal vascular disease. Complete recovery from the symptoms of intramedullary disorders remains difficult to achieve by available treatments. (author)

  8. Intramedullary disorders diagnosed by MRI. Clinical course in 23 cases

    Energy Technology Data Exchange (ETDEWEB)

    Nagata, Kensei; Ohashi, Teruaki; Ishibashi, Kazumasa; Hirohashi, Akiyuki; Sato, Kimiaki [Kurume Univ., Fukuoka (Japan). School of Medicine

    1996-09-01

    We report the clinical course of 23 cases with intramedullary disorders diagnosed by MRI. Spinal vascular disease was the most common, and occurred in 11 cases, intramedullary tumor occurred in 6, and multiple sclerosis, myelitis, spinal edema each in 2. The characteristic MRI findings of the intramedullary disorders were spinal cord swelling on T1 weighted image and changes in the intensity on the T2 weighted image. Surgical treatment was performed in 5 of the 11 with spinal vascular disease and in 6 with an intra-medullary tumor. One patient with AV malformation underwent embolization of the spinal artery. The other 11 received conservative treatment. The period of follow-up ranged from 6 months to 9 years after onset. Complete recovery from symptoms was achieved in only 2 patients, some recovery was achieved in 8, no change in 10, and deterioration occurred in 3. In conclusion, it has become easy to diagnose intramedullary disorders by utilizing MRI. However, an accurate qualitative diagnosis is difficult except for spinal vascular disease. Complete recovery from the symptoms of intramedullary disorders remains difficult to achieve by available treatments. (author)

  9. Custom total knee replacement in a dog with femoral condylar bone loss.

    Science.gov (United States)

    Liska, William D; Marcellin-Little, Denis J; Eskelinen, Esa V; Sidebotham, Christopher G; Harrysson, Ola L A; Hielm-Björkman, Anna K

    2007-06-01

    To report surgical planning, technique, and outcome of custom total knee replacement (TKR) performed to manage a medial femoral condylar nonunion in a dog. Clinical case report. A 3-year-old, 20 kg Karelian Bear Hound. Computed tomographic scan of the left pelvic limb was used to build a stereolithography model of the distal portion of the femur. The model was used to create a custom augment to replace the missing medial femoral condyle and a custom stem for intramedullary condylar cemented fixation. The augment and stem were adapted to femoral and tibial components already available. The model was used to rehearse the surgery and then the custom prosthesis was implanted. Weight bearing returned 8 hours after surgery and improved thereafter. Joint alignment was normal and prosthetic joint motion was 60-165 degrees postoperatively. The dog resumed moose hunting 3 months after surgery. Peak vertical force and impulse of the operated limb measured 17 months after surgery were 65% and 47% of the normal, contralateral limb. Based on short-term follow-up, cemented canine TKR was successfully achieved for management of a severely abnormal stifle joint. With further refinement and development of commercially available prostheses, TKR should be possible for canine patients.

  10. Posterior dislocation of a native hip joint associated with ipsilateral per-trochanteric fracture: A rare case report

    Directory of Open Access Journals (Sweden)

    Mazin Fageir

    2018-02-01

    Full Text Available We describe a case of traumatic posterior dislocation of a native hip joint associated with ipsilateral comminuted inter-trochanteric femoral fracture. In our case, closed reduction was attempted but proved unsuccessful. Taking into account the planned subsequent intra-medullary femoral nail, open reduction through a lateral incision was undertaken. Post-operatively, the planned mobility was for a non-weight bearing period of 6 weeks followed by a partial-weight bearing period of 6 weeks before progressing to full-weight bearing. Post-operatively, the patient completed a comprehensive course of physiotherapy. At five months, he was able to walk for five miles over the course of a weekend. At six months, the patient was looking at phased return to work as a fire fighter. Radiographs taken at the time demonstrated evidence of healing to his inter-trochanteric fracture. At ten months, the patient was back to normal duties at work as a fire fighter.

  11. [Allogeneic vascularized transplantation in cases of bone and joint defects].

    Science.gov (United States)

    Hofmann, G O; Kirschner, M H; Gonschorek, O; Bühren, V

    1999-06-01

    This paper presents preliminary results of allogeneic vascularized transplantations of three femoral diaphyses and four total human knee joints. Grafts were harvested from multi-organ-donors and immediately transplanted. Osteosyntheses were performed employing intramedullary nails. Vascular pedicles of the grafts were anastomosed in end-to-side technique. Immunosuppression mainly based on Cyclosporine and Azathioprine. Grafts' perfusion was demonstrated by DSA and Duplex-sonograms, bone metabolism by SPECT-scintigraphy. Five months following transplantation osteotomies demonstrated consolidation in conventional X-rays. Biopsies of the grafted bone revealed intact osteocytes and arthroscopy demonstrated intact synovial, chondral and ligamentous structures. From the technical aspect vascularized transplantation of the femoral diaphyses and total knee joints is feasible. The main problems are of immunologic nature. Transplantations were performed respecting the ABO-compatibility but with a large HLA-mismatch. Acute and chronic rejection crises may damage the grafts. At least in synovial joints live-long immunosuppression of the recipients seems to be unavoidable.

  12. [Simultaneous existence of unicameral bone cysts involving the femur and ischium].

    Science.gov (United States)

    Makris, Vassilios; Papavasiliou, Kyriakos A; Bobos, Mattheos; Hytiroglou, Prodromos; Kirkos, John M; Kapetanos, George A

    2009-01-01

    We report a 30-year-old male patient with two unicameral bone cysts (UBC) simultaneously located in the proximal third of the right femur and ipsilateral ischium ramus, respectively. Fine needle biopsies were attempted for both lesions. Biopsy of the femoral lesion under local anesthesia was unsuccessful, so an open biopsy was performed which confirmed the diagnosis of UBC. Biopsy of the ischial lesion was not sufficient for diagnosis. Cytological examination of both specimens showed no other benign or malignant pathology. The femoral lesion was treated with intralesional (due to its large size) excision-curettage, bone grafting, and the introduction of a long gamma locking intramedullary nail to prevent the occurrence of a pathological fracture. The ischial lesion was left untreated and followed conservatively. The patient was free of any symptoms and complications three years postoperatively. This is the first report of an adult patient with UBCs simultaneously located both in a long tubular bone (femur) and a flat bone (ischium ramus).

  13. Sliding hip screw versus IM nail in reverse oblique trochanteric and subtrochanteric fractures. A study of 2716 patients in the Norwegian Hip Fracture Register.

    Science.gov (United States)

    Matre, Kjell; Havelin, Leif Ivar; Gjertsen, Jan-Erik; Vinje, Tarjei; Espehaug, Birgitte; Fevang, Jonas Meling

    2013-06-01

    Intramedullary nailing is commonly recommended as the treatment of choice for transverse/reverse oblique trochanteric (AO/OTA type A3=intertrochanteric) and subtrochanteric fractures. However, only to a limited extent is this approach supported by superior results in well designed clinical trials, and the sliding hip screw (SHS) is still a frequently used implant for these fractures. The aim of the present study was to compare IM nails and SHS in the treatment of transverse/reverse oblique trochanteric and subtrochanteric fractures using data from the Norwegian Hip Fracture Register (NHFR). Data on 2716 operations for acute transverse/reverse oblique trochanteric or subtrochanteric fractures were collected from the NHFR from 2005 to 2010. Surgeons reported patient characteristics and details from initial surgery and reoperations, and patients answered questionnaires about pain, satisfaction, and quality of life (EQ-5D) 4, 12, and 36 months postoperatively. Reoperation rates were calculated using Kaplan-Meier analyses. Primary outcome measures were pain (Visual Analogue Scale (VAS)), satisfaction (VAS), quality of life (EQ-5D), and reoperation rates at one year. The treatment groups were similar regarding age, gender, ASA-class, cognitive impairment, and preoperative EQ-5Dindex score. At one year reoperation rates were 6.4% and 3.8% for SHS and IM nails, respectively (p=0.011). Patients treated with SHS also had slightly more pain (VAS 30 vs. 27, p=0.037) and were less satisfied (VAS 31 vs. 36, p=0.003) compared to patients treated with IM nail. There was no statistically significant difference in the EQ-5Dindex score, but the mobility was significantly better for the IM nail group. 12 months postoperatively patients with transverse/reverse oblique trochanteric and subtrochanteric fractures operated with a SHS had a higher reoperation rate compared to those operated with an IM nail. Small differences regarding pain, satisfaction, quality of life, and mobility were

  14. Surgical anatomy of the nail apparatus.

    NARCIS (Netherlands)

    Haneke, E.

    2006-01-01

    Nail surgery is an integral part of dermatologic surgery. An in-depth knowledge of the anatomy, biology, physiology, and gross pathology of the entire nail unit is essential. In particular, knowledge of nail histopathology is necessary to perform diagnostic nail biopsies and other nail procedures

  15. A computational study on the effect of fracture intrusion distance in three- and four-part trochanteric fractures treated with Gamma nail and sliding hip screw.

    Science.gov (United States)

    Goffin, Jérôme M; Pankaj, Pankaj; Simpson, A Hamish

    2014-01-01

    Using finite element analysis, the behaviors of the Gamma nail and the sliding hip screw (SHS) were compared in an osteoporotic bone model for the fixation of three- and four-part trochanteric fractures (31-A2 in the AO classification, types IV and V in Evans' classification). The size of the medial fragment was varied based on clinical data, and the case of a fractured greater trochanter was also considered. Our results showed that for Evans' type V stabilized with a Gamma nail and for Evans' types IV and V with the SHS, cancellous bone around the lag screw is susceptible to yielding, thus indicating a risk of cut-out. The volume of bone susceptible to yielding increases with an increase in size of the medial fragment. Conversely, Evans' type IV with a Gamma nail was not predicted to cut out. Our findings suggest that future clinical trials investigating fixation of unstable proximal fractures should include the size of the medial fragment and the integrity of the greater trochanter as covariables and be powered to evaluate whether intramedullary devices are superior to SHSs for Evans' type IV fractures and inferior/equivalent for type V. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  16. Laterally Loaded Nail-Plates

    DEFF Research Database (Denmark)

    Nielsen, Jacob; Rathkjen, Arne

    Load-displacement curves from about 200 short-term and laterally loaded nail-plate joints are analysed. The nail-plates are from Gang-Nail Systems, type GNA 20 S. The test specimens and the measuring systems are described. The tests are divided into 32 different series. The influence of the number...

  17. Cephalomedullary fixation for femoral neck/intertrochanteric and ipsilateral shaft fractures: surgical tips and pitfalls

    Directory of Open Access Journals (Sweden)

    Bali Kamal

    2013-02-01

    Full Text Available 【Abstract】Objective: Surgical management op-tions for femoral shaft fracture and ipsilateral proximal fe-mur fracture vary from single-implant to double-implant fixation. Cephalomedullary fixation in such fractures has rela-tive advantages over other techniques especially because of less soft tissue dissection and immediate postoperative weight bearing with accelerated rehabilitation. However, the surgery is technically demanding and there is a paucity of literature describing the surgical techniques for this fixation. The aim of the study was to describe the surgical technique of cephalomedullary fixation for femoral shaft fracture and ipsilateral proximal femur fracture. Methods: Sixteen cases (10 males and 6 females with a mean age of 41.8 years of ipsilateral proximal femur and shaft fractures were treated by single-stage cephalomedullary fixa-tion at tertiary level trauma center in northern India. The fractures were classified according to AO classification. An intraoperative record of duration of surgery as well as tech-nical challenges unique to each fracture pattern was kept for all the patients. Results: The most common proximal femoral pattern was AO B2.1 observed in 9 of our patients. The AO B2.3 fractures were seen in 4 patients while the AO A1.2 fractures in 3 patients. Four of the AO B2.1 and 2 of the AO B2.3 frac-tures required open reduction with Watson-Jones approach. The mean operative time was around 78 minutes, which tended to decrease as the surgical experience increased. There was only one case of malreduction, which required revision surgery. Conclusion: Combination of ipsilateral femoral shaft fracture and neck/intertrochanteric fracture is a difficult frac-ture pattern for trauma surgeons. Cephalomedullary nail is an excellent implant for such fractures but it requires careful insertion to avoid complications. Surgery is technically de-manding with a definite learning curve. Nevertheless, a ma-jority of these

  18. Selective angiography of the avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Joong Chan; Park, Cheong Hee; Rho, Tae Jin; Yune, Seung Ho; Rhee, Byung Chull [Chung Nam National University College of Medicine, Deajeon (Korea, Republic of)

    1988-10-15

    The diagnosis of the avascular of the femoral head (AVN) has advanced. RI scan, intraosseous pressure monitoring, intramedullary venography, CT, MRI, and selective femoral angiography are used in diagnosis. Among these methods, selective or superselective angiography is necessary to study the change of the vessels of the hip, because the vascular insufficiency could be a major etiology of AVN. Selective femoral angiography was performed for 23 hips of 22 patients who were suspected as AVN by simple rediographs and RI scans in order to estimate the change of vascularity of the femoral head. The results were as follow. 1. The alteration of vasculature appeared in 21 cases among all 23 cases (91%), which included 100% in the traumatic group (4/4 cases) and 90% in nontraumatic group (17/19 cases). 2. The affected vessles in nontraumatic group were the proximal portion of the posterior branch of the medical circumflex artery in 2 cases, the modportion of posterior branch in 2 cases, the distal portion of the posterior branch in 11 cases, and superior capsular branch in 2 cases. 3. The affected vessels in traumatic group were proximal portion in 1 cases, midportion in 1 case, and superior capsular artrey in 2 cases. 4. The obstruction of inferior casular artery was noted in 6 cases of nontraumatic group. 5. The retrograde filling of the posterior branch of medial circumflex artery were noted in 1 case from superior gluteal artery, in 1 case from inferior gluteal artery, in 1 case form superior and inferior gluteal artery and retrograde filling of inferior gluteal artery from medial circumflex artery was in 6 cases.

  19. Selective angiography of the avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Choi, Joong Chan; Park, Cheong Hee; Rho, Tae Jin; Yune, Seung Ho; Rhee, Byung Chull

    1988-01-01

    The diagnosis of the avascular of the femoral head (AVN) has advanced. RI scan, intraosseous pressure monitoring, intramedullary venography, CT, MRI, and selective femoral angiography are used in diagnosis. Among these methods, selective or superselective angiography is necessary to study the change of the vessels of the hip, because the vascular insufficiency could be a major etiology of AVN. Selective femoral angiography was performed for 23 hips of 22 patients who were suspected as AVN by simple rediographs and RI scans in order to estimate the change of vascularity of the femoral head. The results were as follow. 1. The alteration of vasculature appeared in 21 cases among all 23 cases (91%), which included 100% in the traumatic group (4/4 cases) and 90% in nontraumatic group (17/19 cases). 2. The affected vessles in nontraumatic group were the proximal portion of the posterior branch of the medical circumflex artery in 2 cases, the modportion of posterior branch in 2 cases, the distal portion of the posterior branch in 11 cases, and superior capsular branch in 2 cases. 3. The affected vessels in traumatic group were proximal portion in 1 cases, midportion in 1 case, and superior capsular artrey in 2 cases. 4. The obstruction of inferior casular artery was noted in 6 cases of nontraumatic group. 5. The retrograde filling of the posterior branch of medial circumflex artery were noted in 1 case from superior gluteal artery, in 1 case from inferior gluteal artery, in 1 case form superior and inferior gluteal artery and retrograde filling of inferior gluteal artery from medial circumflex artery was in 6 cases.

  20. Comparative characteristics of osteosynthesis techniques in patients with comminuted diaphyseal femoral fractures

    Directory of Open Access Journals (Sweden)

    A. P. Barabash

    2013-01-01

    Full Text Available The comparative analysis of the results of the surgical treatment of 130 patients with closed comminuted unilateral diaphyseal femoral fractures, including assessment of anatomic functional outcomes of treatment according to the technique of the standardized investigations in traumatology and orthopedy and determination of quality of life according to SF-36 method is carried out. Osteosynthesis with the help of external fixation devices was performed in 36 patients, intramedullary interlocking osteosynthesis - in 57 patients, compression plating - in 37 patients. Level of anatomic functional rehabilitation of the patients in the early postoperative period made up 69-79 %, 6 months later increased up to 74-92%, and after the expiration of 12 months the level of rehabilitation reached 85-99%. During the treatment quality of life concerning physical component was within the limits from 36,8 up to 55,5 %, and concerning mental component - 54,3-60,8 %. After the expiration of a year increase in the parameters of physical and mental components up to 55,7 - 59,8 % and 57,2-65,8 % is detected respectively. In the group where the transosseous osteosynthesis technique was applied we got 93,7-95 % of positive outcomes, with the average disability period of 212,3±18,1 days. In 47,2 % of cases the following complications are observed: knee contracture - 7; inflammation of the soft tissues located near the transosseous fixators - 5 (13,9%; shortening of the limb less than 5% of its length - 3; false joint formation - 1; fracture union with formation of varus deformity in the femoral bone - 1. When using intramedullary interlocking osteosynthesis we had positive results in 96,5 % of cases, with the average period of disability 176±17,8 days. In 10,5 % cases the following complications are observed: suture sinus - 1(1,75 %; femoral osteomyelitis - 1; break of the design - 1; false joint formation - 1; knee contracture - 1; shortening of the limb less than 5

  1. Yellow Nail Syndrome - a Case Report

    Directory of Open Access Journals (Sweden)

    Paravina Mirjana

    2015-06-01

    Full Text Available Yellow nail syndrome is a rare disease of unknown etiology. It is clinically characterized by a triad of yellow nails, lymphedema at one or more sites, and chronic respiratory disease (bronchitis, bronchiectasis and rhinosinusitis. All nails may be affected, but some may be spared. The nail plates are yellowish green, thickened, occasionally with transverse ridging and onycholysis, with increased longitudinal and transversal over-curvature, with partial or complete separation of the nail plate from the nail bed, without lunula and cuticle and slow nail growth rate. The lymphedema is usually peripheral, affecting the lower limbs, or in the form of pleural effusion.

  2. [Effect factors analysis of knee function recovery after distal femoral fracture operation].

    Science.gov (United States)

    Bei, Chaoyong; Wang, Ruiying; Tang, Jicun; Li, Qiang

    2009-09-01

    To investigate the effect factors of knee function recovery after operation in distal femoral fractures. From January 2001 to May 2007, 92 cases of distal femoral fracture were treated. There were 50 males and 42 females, aged 20-77 years old (average 46.7 years old). Fracture was caused by traffic accident in 48 cases, by falling from height in 26 cases, by bruise in 12 cases and by tumble in 6 cases. According to Müller's Fracture classification, there were 29 cases of type A, 12 cases of type B and 51 cases of type C. According to American Society of Anesthesiologists (ASA) classification, there were 21 cases of grade I, 39 cases of grade II, 24 cases of grade III, and 8 cases of grade IV. The time from injury to operation was 4 hours to 24 days with an average of 7 days. Anatomical plate was used in 43 cases, retrograde interlocking intramedullary nail in 37 cases, and bone screws, bolts and internal fixation with Kirschner pins in 12 cases. After operation, the HSS knee function score was used to evaluate efficacy. Ten related factors were applied for statistical analysis, to knee function recovery after operation in distal femoral fractures, such as age, sex, preoperative ASA classification, injury to surgery time, fracture type, treatment, reduction quality, functional exercise after operation, whether or not CPM functional training and postoperative complications. Wound healed by first intention in 88 cases, infection occurred in 4 cases. All patients followed up 16-32 months with an average of 23.1 months. Clinical union of fracture was achieved within 3-7 months after operation. Extensor device adhesions and the scope of activities of fracture displacement in 6 cases, mild knee varus or valgus in 7 cases and implant loosening in 6 cases. According to HSS knee function score, the results were excellent in 52 cases, good in 15 cases, fair in 10 cases and poor in 15 cases with an excellent and good rate of 72.83%. Single factor analysis showed that age

  3. Medial pelvic migration of the lag screw in a short gamma nail after hip fracture fixation: a case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Li Xinning

    2010-08-01

    Full Text Available Abstract Hip fractures are a common injury among the elderly. Internal fixation with an intramedullary (IM system has gained popularity for the treatment of intertrochanteric femur fractures. Multiple complications associated with IM fracture fixation have been described, however, we report a rare complication of medial pelvic migration of the lag screw of a short IM nail in a stable construct ten weeks post surgery. The patient was subsequently treated with Lag Screw removal and revision surgery with a shorter Lag Screw and an accessory cannulated screw acting as a de-rotational device. The patient did well with the revision surgery and was able to return to full activities.

  4. Comparision of the Expandable Nail with Locked Nail in the ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... [5-7] The axial and rotational stability of locked nails depends .... weight bearing was defined as no or minimal pain .... of the nail is changed to load bearing. In delayed .... fractures. J Bone Joint Surg Br 1988;70:206-10. 4.

  5. Nail toxicity induced by cancer chemotherapy.

    Science.gov (United States)

    Gilbar, Peter; Hain, Alice; Peereboom, Veta-Marie

    2009-09-01

    To provide a comprehensive literature review of chemotherapy-induced nail toxicity, including clinical presentation, implicated drugs and approaches for prevention and management. A search of MEDLINE and EMBASE (1966-2008) databases was conducted using the terms (and variations of the terms) antineoplastic agents, nails, nail toxicity, onycholysis, and paronychia. Bibliographies from selected articles were reviewed for appropriate references. The retrieved literature was reviewed to include all articles relevant to the clinical presentation, diagnosis, incidence, prevention, and treatment of chemotherapy-induced nail toxicity. Nail toxicity is a relatively uncommon adverse effect linked to a number of chemotherapeutic agents. Clinical presentation varies, depending on which nail structure is affected and the severity of the insult. Nail changes may involve all or some nails. Toxicity may be asymptomatic and limited to cosmetic concerns, however, more severe effects, involving pain and discomfort can occur. Taxanes and anthracyclines are the antineoplastic drug groups most commonly implicated. It is suggested that the administration schedule may influence the incidence of nail abnormalities, for example reported cases linked to the weekly administration of paclitaxel.Before instituting chemotherapy, patients should be educated regarding potential nail toxicities and strategies for prevention implemented. Management includes appropriate nail cutting, avoiding potential irritants, topical, or oral antimicrobials, and possibly cessation or dose reduction of the offending agent. Cryotherapy, through the application of frozen gloves or socks, has been beneficial in reducing docetaxel-induced nail toxicity and may be effective for other drugs.

  6. ‘Tumour-induced osteomalacia’

    Science.gov (United States)

    Munoz, Javier; Michel Ortega, Rosa; Celzo, Florence; Donthireddy, Vijayalakshmi

    2012-01-01

    A 60-year-old man presented 2 years before his diagnosis with long-standing muscle cramping, progressive generalised weakness and chronic hip pain. The patient was found to have bilateral femoral neck pathologic fractures therefore, underwent reamed intramedullary nailing of both femurs. Laboratory studies showed hypophosphataemia. Bone marrow biopsy was negative for malignancy. Positron emission tomography demonstrated fludeoxyglucose uptake only in the posterior neck. Bone scan showed innumerable foci of increased activity throughout the skeleton consistent with pseudofractures seen in osteomalacia. Fine needle aspiration from the mass in the neck revealed a phosphaturic mesenchymal tumour of mixed connective tissue type. Resection of the mass in the neck resulted in resolution of generalised complaints with no evidence of recurrence with a follow-up of 12 months. PMID:22736784

  7. Segmental transports for posttraumatic lower extremity bone defects: are femoral bone transports safer than tibial?

    Science.gov (United States)

    Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian; Ettinger, Max; Jagodzinski, Michael; Hankemeier, Stefan

    2011-02-01

    The long-term outcomes following femoral and tibial segment transports are not well documented. Purpose of the study is to compare the complication rates and life quality scores of femoral and tibial transports in order to find what are the complication rates of femoral and tibial monorail bone transports and if they are different? We retrospectively analyzed the medical records of 8 femoral and 14 tibial consecutive segment transports performed with the monorail technique between 2001 and 2008 in our institution. Mean follow-up was 5.1 ± 2.1 years with a minimum follow-up of 2 years. Aetiology of the defects was posttraumatic in all cases. Four femoral (50%) and nine tibial (64%) fractures were open. The Short Form-36 (SF-36) health survey was used to compare the life quality after femoral and tibial bone transports. The Mann-Whiney U test, Fisher exact test, and the Student's two tailed t-test were used for statistical analysis. P ≤ 0.05 was considered to be statistically significant. The tibial transport was associated with higher rates of severe complications and additional procedures (1.5 ± 0.9 vs. 3.4 ± 2.7, p = 0.048). Three patients of the tibial group were amputated because of recurrent infections and one developed a complete regenerate insufficiency that was treated with partial diaphyseal tibial replacement. Contrary to that none of patients of the femoral group developed a complete regenerate insufficiency or was amputated. Tibial bone transports have a higher rate of complete and incomplete regenerate insufficiency and can more often end in an amputation. The authors suggest systematic weekly controls of the CRP value and of the callus formation in patients with posttraumatic tibia bone transports. Further comparative studies comparing the results of bone transports with and without intramedullary implants are necessary.

  8. Strength of titanium intramedullary implant versus miniplate fixation of mandibular condyle fractures.

    Science.gov (United States)

    Frake, Paul C; Howell, Rebecca J; Joshi, Arjun S

    2012-07-01

    To test the strength of internal fixation of mandibular condyle fractures repaired with titanium miniplates versus titanium intramedullary implants. Prospective laboratory experimentation in urethane mandible models and human cadaveric mandibles. Materials testing laboratory at an academic medical center. Osteotomies of the mandibular condyle were created in 40 urethane hemimandible models and 24 human cadaveric specimens. Half of the samples in each group were repaired with traditional miniplates, and the other half were repaired with intramedullary titanium implants. Anteroposterior and mediolateral loads were applied to the samples, and the displacement was measured with reference to the applied force. Titanium intramedullary implants demonstrated statistically significant improved strength and stiffness versus miniplates in the urethane model experimental groups. Despite frequent plastic deformation and mechanical failures of the miniplates, a 1.6-mm-diameter titanium intramedullary pin did not mechanically fail in any of the cases. Intramedullary implantation failures were due to secondary fracture of the adjacent cortical bone or experimental design limitations including rotation of the smooth pin implant. Mechanical implant failures that were encountered with miniplate fixation were not seen with titanium intramedullary implants. These intramedullary implants provide stronger and more rigid fixation of mandibular condyle fractures than miniplates in this in vitro model.

  9. Burnei's technique of femoral neck variation and valgisation by using the intramedullary rod in Osteogenesis imperfecta.

    Science.gov (United States)

    Georgescu, I; Gavriliu, Șt; Nepaliuc, I; Munteanu, L; Țiripa, I; Ghiță, R; Japie, E; Hamei, S; Dughilă, C; Macadon, M

    2014-01-01

    Varus or valgus deviations of the femoral neck in osteogenesis imperfecta have been an ignored chapter because the classic correction procedures were applied in medical practice with unsatisfying results. Until the use of telescopic rods, coronal deviations remained unsolved and the distal configuration of the proximal femoral extremity remained uncorrected or partially corrected, which required an extensive use of the wheel chair or bed immobilization of the patient. The concomitant correction of the complex deformities, coxa vara/valga and femoral integrated configuration, have been a progress which allowed the patients to walk with or without support. The purpose of this study is to present the Burnei's technique, a therapeutic alternative in deformity corrections of the varus or valgus hip in children with osteogenesis imperfecta. The paper is about a retrospective study done in a single center, which analyses Burnei technique and other procedures described in literature. The content of the article is based on a 12 years experience on a batch of 51 patients with osteogenesis imperfecta from which 10 patients (13 hips) presented frontal plane deviations of the femoral neck. All the patients with osteogenesis imperfecta who presented coxa vara or valga were submitted to investigations with the purpose of measuring blood loss, the possibility of extending the surgical intervention to the leg, the association of severe deformities of the proximal extremity of the femur and the necessity of postoperative intensive care. Burnei's technique: The operation was first performed in 2002. A subtrochanteric osteotomy was made in an oblique cut, from the internal side to the external side and from proximal to distal for coxa vara, or by using a cuneiform resection associated with muscular disinsertions. Only telescopic rods were used for osteosynthesis. There are a few articles in literature, which approach corrections of vara or valgus deviations in osteogenesis imperfecta

  10. [Role of Hackethal bundle nailing in the treatment of humerus fractures: about 80 cases].

    Science.gov (United States)

    Margad, Omar; Boukhris, Jalal; Sallahi, Hicham; Daoudi, Mohamed; Azriouil, Ouahb; Koulali, Khalid

    2016-01-01

    The main debate regarding humerus fractures focuses on their therapeutic indications because any type of orthopedic or surgical stabilization finds unconditional and sometimes vehement defenders. We conducted a retrospective study of 80 patients treated initially with Hackethal's technique of intramedullary bundle nailing in the Department of Orthopaedics and Traumatology at Avicenne Military Hospital between January 2000 and January 2012. The fractures were classified according to AO classification and Hackethal classification (modified by De La Caffinière). Functional assessment was based on the modified Stewart and Hundley classification. We got 60 very good outcomes, 6 good outcomes, 2 quite good outcomes and 2 poor outcomes. The two cases with poor outcomes had pseudarthrosis. We noted no iatrogenic radial nerve palsy, infection or pin migration. The average time for union was 9 weeks and 6 days. This is a reliable, easy to perform and low cost technique, which provides a good stabilization of the fracture site, allowing early mobilization with excellent functional outcomes.

  11. Exploring metal artifact reduction using dual-energy CT with pre-metal and post-metal implant cadaver comparison: are implant specific protocols needed?

    Science.gov (United States)

    Wellenberg, Ruud H H; Donders, Johanna C E; Kloen, Peter; Beenen, Ludo F M; Kleipool, Roeland P; Maas, Mario; Streekstra, Geert J

    2017-08-25

    To quantify and optimize metal artifact reduction using virtual monochromatic dual-energy CT for different metal implants compared to non-metal reference scans. Dual-energy CT scans of a pair of human cadaver limbs were acquired before and after implanting a titanium tibia plate, a stainless-steel tibia plate and a titanium intramedullary nail respectively. Virtual monochromatic images were analyzed from 70 to 190 keV. Region-of-interest (ROI), used to determine fluctuations and inaccuracies in CT numbers of soft tissues and bone, were placed in muscle, fat, cortical bone and intramedullary tibia canal. The stainless-steel implant resulted in more pronounced metal artifacts compared to both titanium implants. CT number inaccuracies in 70 keV reference images were minimized at 130, 180 and 190 keV for the titanium tibia plate, stainless-steel tibia plate and titanium intramedullary nail respectively. Noise, measured as the standard deviation of pixels within a ROI, was minimized at 130, 150 and 140 keV for the titanium tibia plate, stainless-steel tibia plate and titanium intramedullary nail respectively. Tailoring dual-energy CT protocols using implant specific virtual monochromatic images minimizes fluctuations and inaccuracies in CT numbers in bone and soft tissues compared to non-metal reference scans.

  12. EPR spectroscopic investigation of psoriatic finger nails.

    Science.gov (United States)

    Nakagawa, Kouichi; Minakawa, Satoko; Sawamura, Daisuke

    2013-11-01

    Nail lesions are common features of psoriasis and found in almost half of the patients. However, there is no feasible spectroscopic method evaluating changes and severity of nail psoriasis. EPR (electron paramagnetic resonance) might be feasible for evaluating nail conditions in the patients of psoriasis. Finger nails of five cases with nail psoriasis, (three females and two males) were examined. Nail samples were subjected to the EPR assay. The small piece of the finger nail (1.5 × 5 mm(2)) was incubated in ~50 μM 5-DSA (5-doxylstearic acid) aqueous solutions for about 60 min at 37°C. After rinsing and wiping off the excess 5-DSA solution, the nail samples were measured by EPR. EPR spectra were analyzed using the intensity ratio (Fast/Slow) of the two motions at the peaks of the lower magnetic field. We observed two distinguishable sites on the basis of the EPR results. In addition, the modern EPR calculation was performed to analyze the spectra obtained. The nail psoriasis-related region is 2~3 times higher than that of the control. The present EPR results show that there are two distinguishable sites in the nail. In the case of nail psoriasis, the fragile components are 2~3 times more than those of the control. Thus, the EPR method is thought to be a novel and reliable method of evaluating the nail psoriasis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. Utility of gel nails in improving the appearance of cosmetically disfigured nails: Experience with 25 cases

    Directory of Open Access Journals (Sweden)

    Soni Nanda

    2014-01-01

    Full Text Available Background: Gel nails are a commonly used cosmetic procedure, though their use by dermatologists has not been evaluated. These can be used to improve the appearance of cosmetically disfigured nails where other treatment options have failed; the condition is self-limiting or irreversible; or to camouflage the dystrophy until healing. Materials and Methods: A prospective, uncontrolled, open-label study on 25 participants presenting with cosmetically disfigured nails was undertaken. Mycologically negative, consenting patients with various nail plate surface abnormalities like trachyonychia (n =8; superficial pitting (n =6; onychorrhexis (n =4; superficial pitting with onychoschizia (n =3; Beau′s lines (n =3 and pterygium (n =1 were included. The patients received gel nail application using Ranara gel nail kit ® . Extra care was taken to avoid any damage to cuticle. Standard pre- and post-treatment photographs were taken to assess improvement. Patient satisfaction score (1-10; Global assessment score of improvement (no improvement to excellent improvement and any side effects reported were recorded. Results: The average age of treated patients was 30.44±11.39 years (range 18-60 years. A total of 69 nails were treated (average of 2.76 per patient. Post-procedure, the average patient satisfaction score was 9.08 ± 0.86 (range 7-10. The Global assessment showed excellent improvement (40% cases; good improvement (56% cases and mild improvement in the single case of pterygium treated. Conclusions: The use of Gel nails in patients with cosmetically disfiguring nail plate surface abnormalities (like trachyonychia, onychoschizia, pitting, etc. was found to produce good to excellent improvement in most of the cases. The patient satisfaction with the procedure was rated as high. This, coupled with absence of side effects, make gel nails a valuable tool in improving cosmesis and satisfaction among patients presenting with nail plate surface abnormalities

  14. Extent and Morbidity of Lateralization of a Trochanteric Fixation Nail Blade.

    Science.gov (United States)

    Sandifer, Phillip A; Hulick, Robert M; Graves, Matthew L; Spitler, Clay A; Russell, George V; Hydrick, Josie M; Jones, LaRita C; Bergin, Patrick F

    2017-09-01

    This study examined the incidence and risk factors associated with lateral helical blade migration and trochanteric pain with the trochanteric fixation nail. A retrospective review was performed of 141 cases of pertrochanteric femur fracture treated with a trochanteric fixation nail at a level I trauma center over a period of 42 months. Exclusion criteria included follow-up of less than 60 days, preexisting osteonecrosis of the femoral head, and prophylactic trochanteric fixation nail treatment. Patient demographics, operative findings, and radiographic findings were recorded. Medical records were reviewed to identify symptomatic hardware. Overall, 27 patients (19.1%) were symptomatic, and 3 (2.1%) required revision surgery for blade prominence. Of the patients, 42 (30%) had lateralization of greater than 1 cm, and 16 of these (38.1%) were symptomatic (Pfractures showing lateralization of greater than 1 cm. The quality of calcar reduction nearly reached statistical significance, and 44.8% of patients who had inadequate reduction had lateralization of greater than 1 cm compared with 26.4% of patients who had adequate reduction (P=.054). Lateralization of greater than 1 cm was directly associated with the presence of symptoms (Ptrochanteric pain (P=.007). Multivariate analysis showed that increasing tip-apex distance, inadequate calcar reduction, and greater fracture severity were predictive of excessive lateralization of greater than 1 cm. Nearly 20% of patients had lateral hip pain associated with cephalomedullary fixation. Final lateralization of the helical blade of greater than 1 cm was a very strong predictor of symptoms. During preoperative counseling, surgeons should caution patients about this relatively frequent and likely underreported complication. [Orthopedics. 2017; 40(5):e886-e891.]. Copyright 2017, SLACK Incorporated.

  15. Early Complications in Proximal Femoral Nailing Done for Treatment of Subtrochanteric Fractures

    Directory of Open Access Journals (Sweden)

    B Kanthimathi

    2012-03-01

    Full Text Available AIM: To analyse the early complications following the use of PFN in subtrochanteric fractures. Background: Osteosynthesis with PFN in subtrochanteric fracture features the advantages of high rotational stability of the head–neck fragment, an unreamed implantation technique and the possibility of static or dynamic distal locking. However, the use of the nail requires technical expertise and is accompanied by some risks of error which can lead to osteosynthesis failure. METHODS: Between May 2009 and May 2011, 50 consecutive patients with PFN fixations for subtrochanteric fractures were observed for intraoperative and postoperative complications. RESULTS: We identified intraoperative technical difficulties in four patients and six patients showed postoperative complications. CONCLUSION: When subtrochanteric fractures are to be stabilised with a PFN, the precise and expert technical performance of implantation is the basic surgical requirement. Good reduction with minimal dissection and the use of an appropriate implant is necessary to avoid treatment failure.

  16. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... skin, hair, and nails Skin dictionary Camp Discovery Good Skin Knowledge lesson plans and activities Video library ... biting. Replace the nail-biting habit with a good habit: When you feel like biting your nails, ...

  17. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... Center Coding and reimbursement Coding MACRA Fee schedule Managing a practice Prior authorization assistance Evaluating practice models ... Child nail care Manicure safety Nail biting Nail changes a dermatologist should examine Anti-aging skin care ...

  18. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... Part 1: Structure Part 2: Origin Part 3: Function Textbook Study notes Image library 3-D animated ... hair, and nail care Nail care Nail biting "); (function () { var a = "", b = [ "adid=aad-aad-1", "site= ...

  19. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... Hair care / hair loss Injured skin Nail care Anti-aging skin care Kids’ zone About skin: Your ... Nail biting Nail changes a dermatologist should examine Anti-aging skin care Kids’ zone Video library Find ...

  20. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... this safe, but awful-tasting formula discourages many people from biting their nails. Get regular manicures: Spending ... longer bite any of your nails. For some people, nail biting may be a sign of a ...

  1. Yellow nail syndrome

    Directory of Open Access Journals (Sweden)

    Dixit Ramakant

    2007-01-01

    Full Text Available A case of yellow nail syndrome is described in a forty year old male patient who presented with classical triad of this syndrome i.e. deformed yellow nails, lymph-edema and chronic recurrent pleural effusion. The practical problems in the di-agnosis are also briefly discussed with emphasis on awareness of this rare clinical entity.

  2. FUNCTIONAL RECOVERY AFTER MINIMALLY INVASIVE OSTEOSYNTHESIS IN FRACTURES OF THE SHAFT OF THE RADIUS AND ULNA

    Directory of Open Access Journals (Sweden)

    A. N. Chelnokov

    2016-01-01

    Full Text Available Introduction. Closed intramedullary nailing and external fixation are minimally invasive treatment options in radial and ulnar shaft fractures. We found no comparative studies of these methods in the current literature. Objective. A comparative analysis of both methods in radial and ulnar shaft fractures treated by closed intramedullary nailing and external fixation. Material and methods. 63 patients with forearm shaft fractures treated by closed intramedullary nailing (group I; 24 patients treated by external fixation (group II. All patients were operated within 30 days after injury. Postoperatively, all patients were evaluated clinically (range of motion of elbow and wrist, rotation of the forearm and radiologically. Disability of the Arm, Shoulder and Hand (DASH score was used to assess the functional status and quality of life. Results. The average time of radiological bone union in the group I and group II was 12,6 ± 1,4 weeks. and 12,7 ± 0,6 weeks, accordingly. Statistically significant differences in range of motion in the elbow and wrist occurred in 1 month after the surgery with the advantage in Group I. Restoration of rotation was faster in Group I up to 1 year after surgery. DASH scores in 2 month after the surgery were 11,2±1,96 in the nailing group (as in healthy population and 45,2±6,7 in the external fixation group. In 6 months after surgery the subjective assessment of the quality of life did not differ in both groups. Conclusion. Both minimally invasive methods of surgical stabilization provide restoration of anatomy of the forearm and complete functional recovery in final outcome, but closed intramedullary nailing results with significantly more rapid restoration of range of motions and quality of life measures.

  3. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... Mohs AUC MyDermPath+ Psoriasis Patient education resources Practice Management Center Coding and reimbursement Coding MACRA Fee schedule ... Child nail care Manicure safety Nail biting Nail changes a dermatologist should examine Anti-aging skin care ...

  4. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... and nail care Nail care Nail biting "); (function () { var a = "", b = [ "adid=aad-aad-1", "site=ehs. ... t", "hpos=l", "zone=public", "mcat1=de12", ]; for (var c = 0; c "); (function () { var a = "", b = [ "adid= ...

  5. One-stage lengthening and derotational osteotomy of the femur stabilised with a gamma nail.

    Science.gov (United States)

    van Doorn, R; Leemans, R; Stapert, J W

    1999-12-01

    To study the results of a one-stage lengthening and derotational osteotomy stabilised with a Gamma nail. Retrospective study. 2 hospitals, The Netherlands. 5 patients after failed osteosynthesis of femoral fractures. Mean lengthening of 3 cm and derotation of 30 degrees. Complications and functional results, after a mean follow-up of 43 months (range 30-57). Two patients required dynamisation and a cancellous bone graft to achieve union, which resulted in 1 and 1.5 cm loss of length. One patient had a temporary peroneal neurapraxy. No infections were observed. Our method is not an ultimate solution, but is suitable for one-stage lengthening and derotation osteotomies.

  6. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... nails, or even an entire hand. The goal is to get to the point where you no longer bite any of your nails. For some people, nail biting may be a sign of a more serious psychological ...

  7. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... gloves to prevent biting. Replace the nail-biting habit with a good habit: When you feel like biting your nails, try ... recommend taking a gradual approach to break the habit. Try to stop biting one set of nails, ...

  8. Skin, Hair, and Nails

    Science.gov (United States)

    ... Safe Videos for Educators Search English Español Skin, Hair, and Nails KidsHealth / For Parents / Skin, Hair, and ... piel, el cabello y las uñas About Skin, Hair and Nails Skin is our largest organ. If ...

  9. Dynamic intramedullary crosspinning technique for repair of distal femoral fractures in dogs and cats: 71 cases (1981-1985)

    International Nuclear Information System (INIS)

    Whitney, W.O.; Schrader, S.C.

    1987-01-01

    Dynamic intramedullary crosspinning was used in the surgical treatment of supracondylar and distal physeal fractures of the femur in 129 dogs and cats over a 5-year period; the records of the 44 dogs and 27 cats with follow-up information up to time of bony union were evaluated. The results were good or excellent in 66 of 71 animals (93%). The mean follow-up period was 22 months. Distal pin migration was the major complication (10 animals; 14%). The pin migrated before bony union in 2 animals because of instability and collapse at the fracture site. The pin migrated in 8 animals after bony union and was associated with intermittent lameness. In 5 of these, pin removal was performed and the lameness resolved

  10. Comparison of the Resistance to Bending Forces of the 4.5 LCP Plate-rod Construct and of 4.5 LCP Alone Applied to Segmental Femoral Defects in Miniature Pigs

    Directory of Open Access Journals (Sweden)

    Lucie Urbanová

    2010-01-01

    Full Text Available The study deals with the determination of mechanical properties, namely resistance to bending forces, of flexible buttress osteosynthesis using two different bone-implant constructs stabilizing experimental segmental femoral bone defects (segmental ostectomy in a miniature pig ex vivo model using 4.5 mm titanium LCP and a 3 mm intramedullary pin (“plate and rod” construct (PR-LCP, versus the 4.5 mm titanium LCP alone (A-LCP. The “plate and rod” fixation (PR-LCP of the segmental femoral defect is significantly more resistant (p in vivo experiments in the miniature pig to investigate bone defect healing after transplantation of mesenchymal stem cells in combination with biocompatible scaffolds.

  11. Delayed presentation of carotid artery dissection following major orthopaedic trauma resulting in dense hemiparesis.

    LENUS (Irish Health Repository)

    Edmundson, S P

    2012-01-31

    We report a 30-year-old patient who was involved in a high-velocity road traffic accident and developed a left-sided hemiparesis, which was noted in the post-operative period following bilateral femoral intramedullary nailing. CT scanning of the brain revealed infarcts in the right frontal and parietal lobes in the distribution of the right middle cerebral artery. CT angiography showed occlusion of the right internal carotid artery consistent with internal carotid artery dissection. He was anticoagulated and nine months later was able to walk independently. An awareness of this injury is needed to diagnose blunt trauma to the internal carotid artery. Even in the absence of obvious neck trauma, carotid artery dissection should be suspected in patients with a neurological deficit in the peri-operative period.

  12. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures

    Directory of Open Access Journals (Sweden)

    Vegt P

    2014-12-01

    Full Text Available Paul Vegt,1 Jeffrey M Muir,2 Jon E Block2 1Department of Surgery, Albert Schweitzer Hospital, Dordrecht, The Netherlands; 2The Jon Block Group, San Francisco, CA, USA Abstract: The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS. Keywords: osteoporosis, long bone fracture, bone density, polymeric rod, orthopaedics, surgery

  13. Nail tic disorders: Manifestations, pathogenesis and management.

    Science.gov (United States)

    Singal, Archana; Daulatabad, Deepashree

    2017-01-01

    Nail tic disorders are classic examples of overlap between the domains of dermatology and psychiatry. They are examples of body-focused repetitive behaviors in which there is an irresistible urge or impulse to perform a certain behavior. The behavior is reinforced as it results in some degree of relief and pleasure. Nail tic disorders are common, yet poorly studied and understood. The literature on nail tic disorders is relatively scarce. Common nail tics include nail biting or onychophagia, onychotillomania and the habit tic deformity. Some uncommon and rare nail tic disorders are onychoteiromania, onychotemnomania, onychodaknomania and bidet nails. Onychophagia is chronic nail biting behavior which usually starts during childhood. It is often regarded as a tension reducing measure. Onychotillomania is recurrent picking and manicuring of the fingernails and/or toenails. In severe cases, it may lead to onychoatrophy due to irreversible scarring of the nail matrix. Very often, they occur in psychologically normal children but may sometimes be associated with anxiety. In severe cases, onychotillomania may be an expression of obsessive-compulsive disorders. Management of nail tic disorders is challenging. Frequent applications of distasteful topical preparations on the nail and periungual skin can discourage patients from biting and chewing their fingernails. Habit-tic deformity can be helped by bandaging the digit daily with permeable adhesive tape. Fluoxetine in high doses can be helpful in interrupting these compulsive disorders in adults. For a complete diagnosis and accurate management, it is imperative to assess the patient's mental health and simultaneously treat the underlying psychiatric comorbidity, if any.

  14. Bio-Environment-Induced Degradation and Failure of Internal Fixation Implants

    Directory of Open Access Journals (Sweden)

    Yan Zhou

    2015-10-01

    Full Text Available Internal fixations provide fast healing but their failure remains problematic to patients. Here, we report an experimental study in failure of three typical cases of metals: a bent intramedullary stainless steel nail, a broken exterior pure Ti plate, and a broken intramedullary stainless steel nail. Characterization of the bent nail indicates that those metals are vulnerable to corrosion with the evidence of increased surface roughness and embrittlement. Depredated surface of the Ti plate resulted debris particles in the surrounding tissue of 15.2 ± 6.5 μm in size. Nanoparticles were observed in transmission electron microscope. The electron diffraction pattern of the debris indicates a combination of nanocrystalline and amorphous phases. The failure mode of the broken nail made of stainless steel was found to be fatigue initiated from the surface. This study clearly shows the biological-attack induced surface degradation resulting in debris and fatigue. Future design and selection of implant materials should consider such factors for improvement.

  15. Bio-Environment-Induced Degradation and Failure of Internal Fixation Implants.

    Science.gov (United States)

    Zhou, Yan; Perkins, Luke A; Wang, Guodong; Zhou, Dongsheng; Liang, Hong

    2015-10-15

    Internal fixations provide fast healing but their failure remains problematic to patients. Here, we report an experimental study in failure of three typical cases of metals: a bent intramedullary stainless steel nail, a broken exterior pure Ti plate, and a broken intramedullary stainless steel nail. Characterization of the bent nail indicates that those metals are vulnerable to corrosion with the evidence of increased surface roughness and embrittlement. Depredated surface of the Ti plate resulted debris particles in the surrounding tissue of 15.2 ± 6.5 μm in size. Nanoparticles were observed in transmission electron microscope. The electron diffraction pattern of the debris indicates a combination of nanocrystalline and amorphous phases. The failure mode of the broken nail made of stainless steel was found to be fatigue initiated from the surface. This study clearly shows the biological-attack induced surface degradation resulting in debris and fatigue. Future design and selection of implant materials should consider such factors for improvement.

  16. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... Private payer Medicare physician payment MACRA implementation Alternative payment models Fee schedule State policy State policy and action ... a dermatologist Why see a board-certified dermatologist? Home Public and patients Skin, hair, and nail care Nail care Nail biting "); (function () { var a = "", b = [ " ...

  17. Partial-limb salvage after persistent infection in the distal femoral prosthesis: straight-plasty - a novel technique

    International Nuclear Information System (INIS)

    Kundu, Z. S.; Gupta, V.; Gogna, P.

    2014-01-01

    A 35 years old female had giant cell tumour (GCT) of the distal femur for which wide resection and distal femoral endoprosthetic replacement was performed. Massive infection of prosthesis required removal and replacement of the prosthesis with nail antibiotic cement spacer, which also proved to be futile. Ultimately the whole of the infected thigh had to be excised. The limb could be preserved partially using straight-plasty instead of amputation. Patient is well rehabilitated and doing well at a follow-up of 3 years. (author)

  18. Feasibility of purely endoscopic intramedullary fixation of mandibular condyle fractures.

    Science.gov (United States)

    Frake, Paul C; Goodman, Joseph F; Joshi, Arjun S

    2015-01-01

    The investigators of this study hypothesized that fractures of the mandibular condyle can be repaired using short-segment intramedullary implants and purely endoscopic surgical technique, using a basic science, human cadaver model in an academic center. Endoscopic instrumentation was used through a transoral mucosal incision to place intramedullary implants of 2 cm in length into osteotomized mandibular condyles. The surgical maneuvers that required to insert these implants, including condyle positioning, reaming, implant insertion, and seating of the mandibular ramus, are described herein. Primary outcome was considered as successful completion of the procedure. Ten cadaveric mandibular condyles were successfully repaired with rigid intramedullary internal fixation without the use of external incisions. Both insertion of a peg-type implant and screwing a threaded implant into the condylar head were possible. The inferior portion of the implant remained exposed, and the ramus of the mandible was manipulated into position on the implant using retraction at the sigmoid notch. The results of this study suggest that purely endoscopic repair of fractures of the mandibular condyle is possible by using short-segment intramedullary titanium implants and a transoral endoscopic approach without the need for facial incisions or punctures. The biomechanical advantages of these intramedullary implants, including improved strength and resistance to mechanical failure compared with miniplates, have been recently established. The combination of improved implant design and purely endoscopic technique may allow for improved fixation and reduced surgical- and implant-related morbidity in the treatment of condylar fractures.

  19. Primary malignant intramedullary lymphoma

    International Nuclear Information System (INIS)

    Orrego P, E.; Heinicke Y, H.; Arbaiza A, D.; Yepez R, V.

    1999-01-01

    A case of primary malignant intramedullary lymphoma, localized in the dorsal part of the spinal cord is presented. The clinical symptoms were associated with motor and sensitive deficit. Clinical investigations excluded the presence of lymphoma in other locations in the central nervous system and the extra neural organs. Postoperative radiotherapy and chemotherapy improved relict neurological symptoms. (authors)

  20. Influence of knee flexion and atraumatic mobilisation of infrapatellar fat pad on incidence and severity of anterior knee pain after tibial nailing.

    Science.gov (United States)

    Jankovic, Andrija; Korac, Zelimir; Bozic, Nenad-Bozo; Stedul, Ivan

    2013-09-01

    We evaluated the incidence and aetiology of anterior knee pain (AKP) in a series of patients that underwent intramedullary nailing for stabilisation of tibial fractures. During the preparation of the entry site no excision of the infrapatellar fat was allowed and electrical haemostasis was kept at the lowest level. Medullary canal was reamed and the nails inserted in position of knee flexion over 100 degrees. All fractures were fixed using medial paratendinous approach. Functional outcome was measured using Lysholm knee score. The knee range of movement and return to previous level of activity were also documented and analysed. Mean follow up was 38.9 months (range 12-84 months). In total 60 patients with 62 tibial shaft fractures were analysed. The mean age at the time of final follow up was 49.4 years (range 20-87). In 22 (35.5%) a newly developed and persisting pain in the anterior region of the operated knee was reported. According to VAP scale, the pain was mild (VAS 1-3) in 12 cases (19.4%) and moderate (VAS 4-6) in 10 (16.1%). In 16 cases (73%) the pain was noticed 6-12 months after injury and subjectively related to return to full range of working and recreational activities. The mean Lysholm knee score in the group without AKP was 90.8. In the AKP group with mild pain it was 88.4 and in the group with moderate AKP it was 79.9. Complete return to previous professional and recreational activities occurred in 49/60 patients (81.7%). Content with the treatment regarding expectations in recovery dynamics and return to desired level of activity was present in 98.3% of patients; one patient was unsatisfied with the treatment. Our results indicate that respecting the physiological motion of Hoffa pad and menisci during knee flexion, accompanied with atraumatic mobilisation of retrotendinous fat, reduces incidence and severity of anterior knee pain following intramedullary fixation of tibial shaft fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Treatments of intramedullary spinal cord tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ueyama, Kazumasa; Okada, Akihiro; Echigoya, Naoki; Yokoyama, Toru; Harata, Seiko [Hirosaki Univ., Aomori (Japan). School of Medicine

    2001-04-01

    In order to establish a treatment for intramedullary spinal cord tumors, histology, symptoms (preoperative, upon discharge from the hospital, and at the final follow-up examination), postoperative combination therapy, postoperative complications, and recurrence were assessed in patients with intramedullary spinal cord tumors treated in the author's hospital during the past 19 years. There were 26 subjects (astrocytoma in 8, ependymoma in 6, intramedullary neurinoma in 3, lipoma in 3, hemangioblastoma in 3, cavernous angioma in 1, capillary hemangioma in 1, and enterogenous cyst in 1). Surgery had been performed in 24 of them, and 7 of the tumors were completely resected, 6 were incompletely resected, and 3 were partially resected. Radiotherapy had been performed to treat 7 astrocytomas and 2 ependymomas. Kyphosis was noted as a postoperative complication in 1 patient with an astrocytoma who had received postoperative radiotherapy. Postoperative improvement was better in the patients who had the ependymomas, lipoma, and angioma, and in 1 patient with an astrocytoma. The astrocytomas were very difficult to completely remove surgically, and postoperative radiotherapy was thought to be indispensable. The ependymomas, hemangioblastomas, and angiomas could be surgically resected, but the surgeon must has to exercise sufficient care during the operation. The lipomas were also difficult to resect surgically and intratumoral decompression or decompression should be performed. For adolescents spinal deformity should be considered as one of the postoperative complications. (K.H.)

  2. Treatments of intramedullary spinal cord tumors

    Energy Technology Data Exchange (ETDEWEB)

    Ueyama, Kazumasa; Okada, Akihiro; Echigoya, Naoki; Yokoyama, Toru; Harata, Seiko [Hirosaki Univ., Aomori (Japan). School of Medicine

    2001-04-01

    In order to establish a treatment for intramedullary spinal cord tumors, histology, symptoms (preoperative, upon discharge from the hospital, and at the final follow-up examination), postoperative combination therapy, postoperative complications, and recurrence were assessed in patients with intramedullary spinal cord tumors treated in the author's hospital during the past 19 years. There were 26 subjects (astrocytoma in 8, ependymoma in 6, intramedullary neurinoma in 3, lipoma in 3, hemangioblastoma in 3, cavernous angioma in 1, capillary hemangioma in 1, and enterogenous cyst in 1). Surgery had been performed in 24 of them, and 7 of the tumors were completely resected, 6 were incompletely resected, and 3 were partially resected. Radiotherapy had been performed to treat 7 astrocytomas and 2 ependymomas. Kyphosis was noted as a postoperative complication in 1 patient with an astrocytoma who had received postoperative radiotherapy. Postoperative improvement was better in the patients who had the ependymomas, lipoma, and angioma, and in 1 patient with an astrocytoma. The astrocytomas were very difficult to completely remove surgically, and postoperative radiotherapy was thought to be indispensable. The ependymomas, hemangioblastomas, and angiomas could be surgically resected, but the surgeon must has to exercise sufficient care during the operation. The lipomas were also difficult to resect surgically and intratumoral decompression or decompression should be performed. For adolescents spinal deformity should be considered as one of the postoperative complications. (K.H.)

  3. Optimal management of nail disease in patients with psoriasis

    Directory of Open Access Journals (Sweden)

    Piraccini BM

    2015-01-01

    Full Text Available Bianca Maria Piraccini, Michela Starace Division of Dermatology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Bologna, Italy Abstract: Psoriasis is a common skin disease, with nail involvement in approximately 80% of patients. Nail psoriasis is often associated with psoriatic arthropathy. Involvement of the nails does not always have relationship with the type, gravity, extension, or duration of skin psoriasis. Nail psoriasis can occur at any age and all parts of the nails and the surrounding structures can be affected. Two clinical patterns of nail manifestations have been seen due to psoriasis: nail matrix involvement or nail bed involvement. In the first case, irregular and deep pitting, red spots of the lunula, crumbling, and leukonychia are seen; in the second case, salmon patches, onycholysis with erythematous border, subungual hyperkeratosis, and splinter hemorrhages are observed. These clinical features are more visible in fingernails than in toenails, where nail abnormalities are not diagnostic and are usually clinically indistinguishable from other conditions, especially onychomycosis. Nail psoriasis causes, above all, psychosocial and aesthetic problems, but many patients often complain about functional damage. Diagnosis of nail psoriasis is clinical and histopathology is necessary only in selected cases. Nail psoriasis has an unpredictable course but, in most cases, the disease is chronic and complete remissions are uncommon. Sun exposure does not usually improve and may even worsen nail psoriasis. There are no curative treatments. Treatment of nail psoriasis includes different types of medications, from topical therapy to systemic therapy, according to the severity and extension of the disease. Moreover, we should not underestimate the use of biological agents and new therapy with lasers or iontophoresis. This review offers an investigation of the different treatment options for nail

  4. [Onychomatricoma, a rare lesion of the nail].

    Science.gov (United States)

    Pommepuy, Isabelle; Roblet, Denis; Blaise, Sophie; Delage-Corre, Manuela; Bonnetblanc, Jean-Marie; Fayol, Jacqueline; Labrousse, François

    2004-09-01

    Onychomatricoma is a rare fibroepithelial lesion of the nail matrix with peculiar clinical and histological features. Clinically, it is characterized by a longitudinal band of yellow thickening of the nail plate with transverse overcurvature and splinter hemorrhages. Nail avulsion exposes a villous tumor of the matrix with filamentous digitations extending into multiple holes of the nail plate. Histologically, a thick keratogenous zone forms a thickened nail plate. The lesion in its proximal portion is characterized by deep epithelial invaginations and by a stroma organized in two layers. The distal zone corresponds to multiple fibroepithelial projections extending into the nail plate. The diagnosis can be difficult in the presence of misleading clinical features or when the specimen is incomplete or examined with an improper orientation. Surgical resection is the recommended treatment.

  5. Comparison of three surgical treatment options for unicameral bone cysts in humerus.

    Science.gov (United States)

    Mavčič, Blaž; Saraph, Vinay; Gilg, Magdalena M; Bergovec, Marko; Brecelj, Janez; Leithner, Andreas

    2018-04-23

    Treatment of unicameral bone cysts (UBC) in the humerus with drainage screws is scarcely reported in the literature. The aim of this retrospective study was to compare drainage screws and alternative treatment methods with respect to the number of required surgical procedures to achieve sufficient UBC healing, postoperative fractures/recurrences/complications, and radiological outcome. Medical archives of two tertiary orthopedic referral centers were screened for all patients who were treated surgically for humeral UBC in the period 1991-2015 with a histologically/cytologically confirmed diagnosis. Sex, age, all surgical procedures, fractures, complications, recurrences, and the final radiological outcome were compared between patients treated with drainage screws, elastic intramedullary nails, or curettage with optional grafting. The study included 106 operated patients with a mean age of 10.3 years, with a mean follow-up of 5.7 years. The average number of UBC-related surgical procedures in sex-matched and age-matched treatment groups was 2.7 with drainage screws, 2.8 with intramedullary nails, and 3.5 with curettage/grafting (P=0.54). Intramedullary nails (odds ratio 0.20) and older age (odds ratio for each year 0.83) predicted a lower risk of postoperative UBC recurrence. Patients with drainage screws had the highest UBC recurrence rates and the lowest rates of changed initial treatment method. There was no difference between the treatment groups in the postoperative fracture rate, complications, or the final radiological outcome. UBC treatment in the humerus therefore requires approximately three surgical procedures, irrespective of the treatment modality chosen. Adding an elastic intramedullary nail to a humeral UBC cyst may reduce recurrence risk and prevent further fractures. Level III - therapeutic retrospective comparative study.

  6. Intramedullary cavernous hemangiomas, magnetic resonance studies in four patients

    International Nuclear Information System (INIS)

    Barrena, M.R.; Guelbenzu, S.; Garcia, S.; Bertrol, V.

    1998-01-01

    Intramedullary cavernous hemangiomas are vascular malformations that can be located throughout the entire central nervous system. They are more frequently found in brain than in spinal cord, where it is only possible to diagnose them by magnetic resonance (RM): We present four cases of intramedullary spinal cord cavernoma, three of which were located in the thoracic spine and one in cervical spine. Computed tomography was ineffective in their diagnosis. However, MR disclosed there presence of well-defined tumors producing a thickening of the spinal cord. The signal was heterogeneous in both T1 and T2-weighted images. There were low signal areas due to the presence of calcium and hemosiderin and high intensity signals provoked by methemoglobin within the lesions, which were scarcely enhanced by intravenous gadolinium administration. One of the lesions presented in the form of a large intramedullary hematoma. (Author) 8 refs

  7. Indications and outcome of Open Reduction and Internal Fixation of ...

    African Journals Online (AJOL)

    Background: Open reduction and internal fixation (ORIF) is a well-established surgical treatment of fractures worldwide. However, the indications and modes of stabilization of long bone fractures vary and are evolving .The general trend now is towards fixation with locked intramedullary nail (i.m nail) rather than plate and ...

  8. Nail psoriasis: clinical features, pathogenesis, differential diagnoses, and management

    Directory of Open Access Journals (Sweden)

    Haneke E

    2017-10-01

    Full Text Available Eckart Haneke1–4 1Department of Dermatology, Inselspital, University of Bern, Bern, Switzerland; 2Dermatology Practice Dermaticum, Freiburg, Germany; 3Centro de Dermatología Epidermis, Instituto CUF, Porto, Portugal; 4Department of Dermatology, University Hospital, Gent, Belgium Abstract: Psoriasis is the skin disease that most frequently affects the nails. Depending on the very nail structure involved, different clinical nail alterations can be observed. Irritation of the apical matrix results in psoriatic pits, mid-matrix involvement may cause leukonychia, whole matrix affection may lead to red lunulae or severe nail dystrophy, nail bed involvement may cause salmon spots, subungual hyperkeratosis, and splinter hemorrhages, and psoriasis of the distal nail bed and hyponychium causes onycholysis whereas that of the proximal nail fold causes psoriatic paronychia. The more extensive the involvement, the more severe is the nail destruction. Pustular psoriasis may be seen as yellow spots under the nail or, in case of acrodermatitis continua suppurativa, as an insidious progressive loss of the nail organ. Nail psoriasis has a severe impact on quality of life and may interfere with professional and other activities. Management includes patient counseling, avoidance of stress and strain to the nail apparatus, and different types of treatment. Topical therapy may be tried but is rarely sufficiently efficient. Perilesional injections with corticosteroids and methotrexate are often beneficial but may be painful and cannot be applied to many nails. All systemic treatments clearing widespread skin lesions usually also clear the nail lesions. Recently, biologicals were introduced into nail psoriasis treatment and found to be very effective. However, their use is restricted to severe cases due to high cost and potential systemic adverse effects. Keywords: nail psoriasis, etiology, pathology, quality of life, impact, treatment

  9. Intramedullary spinal cord metastasis from colonic carcinoma presenting as Brown-Sequard syndrome: a case report

    LENUS (Irish Health Repository)

    Kaballo, Mohammed A

    2011-08-02

    Abstract Introduction Intramedullary spinal cord metastasis is very rare. The majority are discovered incidentally during autopsy. Most symptomatic patients present with rapidly progressive neurological deficits and require immediate examination. Few patients demonstrate features of Brown-Séquard syndrome. Radiotherapy is the gold-standard of therapy for Intramedullary spinal cord metastasis. The overall prognosis is poor and the mortality rate is very high. We present what is, to the best of our knowledge, the first case of Intramedullary spinal cord metastasis of colorectal carcinoma presenting as Brown-Séquard syndrome. Case presentation We present the case of a 71-year-old Caucasian man with colonic adenocarcinoma who developed Intramedullary spinal cord metastasis and showed features of Brown-Séquard syndrome, which is an uncommon presentation of Intramedullary spinal cord metastasis. Conclusion This patient had an Intramedullary spinal cord metastasis, a rare form of metastatic disease, secondary to colonic carcinoma. The metastasis manifested clinically as Brown-Séquard syndrome, itself a very uncommon condition. This syndrome is rarely caused by intramedullary tumors. This unique case has particular interest in medicine, especially for the specialties of medical, surgical and radiation oncology. We hope that it will add more information to the literature about these entities.

  10. Is the lag screw sliding effective in the intramedullary nailing in A1 and A2 AO-OTA intertrochanteric fractures? A prospective study of Sliding and None-sliding lag screw in Gamma-III nail

    Directory of Open Access Journals (Sweden)

    Zhu Yi

    2012-09-01

    Full Text Available Abstract Object To compare the Sliding with Non-sliding lag screw of a gamma nail in the treatment of A1 and A2 AO-OTA intertrochanteric fractures. Materials and methods 80 patients were prospectively collected. In each group, AO/OTA 31-A were classified into group A. AO/OTA 31-A2.1 was classified as group B. We classified the A2.2 and A2.3 as group C. According to the set-screw locking formation of Gamma-III, the cases were randomly allocated to Sliding subgroup and Non-sliding subgroup in A, B and C groups. Follow-ups were performed 1, 3, 6 and 12 months postoperatively. Results In the Sliding group, the bone healing rate 3, 6, 12 months postoperatively reached 85.00%, 97.50%, 100% in group A, B and C. Meanwhile, in Non-sliding group, postoperatively, bone healing rate were 90.00%, 95.00% and 97.50% in group A, B and C, respectively. Both differences were not significant. Lower limb discrepancy between Sliding and Non-sliding pattern was significantly different in group C which represent fracture types of AO/OTA 31-A2.2 and A2.3 (0.573 ± 0.019 mm in Non-sliding group, 0.955 mm ± 0.024 mm in Sliding group, P Conclusions As a result, we can conclude that the sliding distance is minimal in Gamma nails and it is related to the comminuted extent of the intertrochanteric area in A1 and A2 AO-OTA intertrochanteric fractures. For treating these kinds of fractures, the sliding of the lag screw of an Gamma nail does not improve any clinical results and in certain cases, such as highly comminuted A1 and A2 fractures, can therefore even benefit from a locked lag screw by tightening the set-screw.

  11. Trace elements in nail polish as a source of contamination of nail clippings when used in epidemiological studies

    International Nuclear Information System (INIS)

    Favaro, P.C.; Bode, P.; De Nadai Fernandes, E.A.

    2005-01-01

    Trace elements were determined in 27 brands of nail polish using INAA so as to estimate the impact of nail polish remainders when using (finger, toe) nail clippings as a bioindicator for epidemiological studies. Fe was found to be present up to almost 1.7% in one brand. No unambiguous correlation between trace elements and color was established, though transparent polish has the lowest trace element concentrations. An estimate of the maximum effect (no removal of the paint) indicates that over-estimates of some trace element levels in nail with more than 200.000% may occur. If nail clippings will be used to study trace elements, very high demands have to be set to the efficiency and selectivity of the cleaning procedure. (author)

  12. Nail gun injuries among construction workers.

    Science.gov (United States)

    Dement, John M; Lipscomb, Hester; Li, Leiming; Epling, Carol; Desai, Tejas

    2003-05-01

    Pneumatic nail guns greatly increase worker productivity and are extensively used in wood frame building construction, with especially high use in residential construction. One surveillance report of nail gun injuries in Washington State has been published; however, other literature consists largely of case reports and case series in trauma journals. The major objective of the current study was to investigate the occurrence of nail gun-associated injuries among construction workers and to identify preventable work-related factors associated with these injuries. Nail gun-related injuries occurring among a cohort of 13,347 carpenters in Ohio who worked union hours during the time period January 1, 1994, until September 30, 1997, were identified by matching the cohort with workers' compensation claims made to the Ohio Bureau of Workers' Compensation. We also analyzed workers' compensation claims for North Carolina Home Builders Association members for the period July 1996-November 1999 to identify nail gun-related injuries. Analyses included stratified analyses of claims by nature and body part injured, calculation of nail gun injury rates, and analyses of free text descriptions of injuries. Overall, nail gun injuries were responsible for 3.9 percent of workers' compensation claims with 8.3 percent to 25.5 percent of claims involving paid lost work time. The overall rate of nail gun injuries (cases per 200,000 work hours) was 0.33 in North Carolina and 0.26 in Ohio, reflecting the greater concentration of wood frame construction workers in the North Carolina population studied. Higher rates of injury were observed for carpenters in North Carolina and among residential carpenters in Ohio. The predominant body part injured was the hands/fingers, with 80 to 89 percent of injuries being nail punctures. Analyses of free text information for puncture injuries found approximately 70 percent of injuries to occur during the framing/sheathing stage of construction. Our data

  13. Cerebral damage caused by nail gun injury

    DEFF Research Database (Denmark)

    Andersen, Chris

    2016-01-01

    Background Accidents with nail guns are rather common, especially in the construction industry. Most injuries involve the extremities and several present with intracerebral injuries. When the patient is unconscious, it can be a big challenge to determine whether the injury is an accident, self....... The forensic examination showed lesions of intracranial surgery and minor bruises on the arms. No sign of defense injuries was found. There were no signs of malfunction of the nail gun-wielding robot. On the side of the machine, there were a handheld nail gun and the police investigated the case as a possible...... criminal act. They found bloodstains on the back of the machine. When awake, the man explained, that by accident, he had hit his head against a nail gun and as a result of this, the nail gun delivered a nail into his skull. Conclusion Sometimes, the circumstances of a case are not clear...

  14. Yellow nail syndrome and bronchiectasis | Adegboye | Nigerian ...

    African Journals Online (AJOL)

    The Yellow Nail Syndrome includes slow growing, opaque yellow nails with exaggerated lateral curvature, associated with lymphoedema and chronic respiratory disorders. The nail changes may precede the lymphoedema by a number of years. Bronchiectasis may be the only chronic respiratory disorder; others include ...

  15. Randomized controlled trial of a water-soluble nail lacquer based on hydroxypropyl-chitosan (HPCH, in the management of nail psoriasis

    Directory of Open Access Journals (Sweden)

    Cantoresi F

    2014-05-01

    Full Text Available Franca Cantoresi,1 Maurizio Caserini,2 Antonella Bidoli,1 Francesca Maggio,1 Raffaella Marino,1 Claudia Carnevale,1 Paola Sorgi,1 Renata Palmieri21Department of Dermatology, Sapienza University, Rome, Italy; 2Scientific Department, Polichem SA, Lugano, Switzerland Background: Nail psoriasis occurs in up to 50% of patients affected by psoriasis, with a significant impact on quality of life that leads to a real clinical need for new therapeutic options. Aim: To confirm whether the strengthening and hardening properties of the hydroxypropyl-chitosan (HPCH nail lacquer could improve the structure of the nail plates on psoriatic nails. Materials and methods: A randomized, double-blind, placebo controlled, parallel-group trial was carried out to evaluate the efficacy and tolerability of a hydrosoluble nail lacquer containing HPCH, Equisetum arvense, and methylsulfonylmethane on nail psoriasis. The test product or a placebo was applied once daily for 24 weeks to all fingernails. Efficacy assessments were performed on the target fingernail by means of the modified Nail Psoriasis Severity Index score. A cut-off score of 4 was considered to define the clinical cure rate (ie, Cure ≤4, Failure >4. Results: After 24 weeks, the clinical cure rate showed the statistically significant superiority of the HPCH nail lacquer compared to placebo in both the intention-to-treat (Fisher's exact test, P=0.0445 and the per protocol population (Fisher's exact test, P=0.0437. This superiority was already present after 16 weeks of treatment. Moreover, the analysis of the modified Nail Psoriasis Severity Index-50 showed a statistically significant clinical improvement after 12 weeks of treatment in comparison to the results obtained after 8 weeks (Fisher's exact test, P<0.05. Conclusion: The trial showed that HPCH nail lacquer could be a new, valid, effective, and safe option for decreasing the signs of nail dystrophy in psoriatic patients. Keywords: nail psoriasis

  16. Nail changes after carbamazepine

    Directory of Open Access Journals (Sweden)

    Chopra Adarsh

    2000-01-01

    Full Text Available Antiepileptics are known to produce different types of side effects including nail changes. A 20-year-old epileptic man had yellowish discolouration followed by dystrophy and onycholysis of his 15 nails after taking carbamazepine for 3 months which cleared within six months after discontinuation of the drug. This type of change has not been reported earlier with carbamazepine

  17. Nail changes and disorders among the elderly

    Directory of Open Access Journals (Sweden)

    Singh Gurcharan

    2005-01-01

    Full Text Available Nail disorders are frequent among the geriatric population. This is due in part to the impaired circulation and in particular, susceptibility of the senile nail to fungal infections, faulty biomechanics, neoplasms, concurrent dermatological or systemic diseases, and related treatments. With aging, the rate of growth, color, contour, surface, thickness, chemical composition and histology of the nail unit change. Age associated disorders include brittle nails, trachyonychia, onychauxis, pachyonychia, onychogryphosis, onychophosis, onychoclavus, onychocryptosis, onycholysis, infections, infestations, splinter hemorrhages, subungual hematoma, subungual exostosis and malignancies. Awareness of the symptoms, signs and treatment options for these changes and disorders will enable us to assess and manage the conditions involving the nails of this large and growing segment of the population in a better way.

  18. Microbiological flora and nail polish: a brief report.

    Science.gov (United States)

    Rayan, G M; Flournoy, D J; Schlageter, P

    1994-11-01

    Removing nail polish and prosthetic nails from operating room (OR) personnel prior to scrubbing and from patients prior to hand surgery is recommended but not practiced in many hospitals. There is concern that nail polish can act as a vehicle for the transfer of infectious agents. This study was designed to determine the incidence of microbiological flora of nail polish in a clinical setting.

  19. Mismatch analysis of humeral nailing. Antegrade versus retrograde insertion

    International Nuclear Information System (INIS)

    Mahaisavariya, B.; Jiamwatthanachai, P.; Aroonjarattham, P.; Aroonjarattham, K.; Wongcumchang, M.; Sitthiseripratip, K.

    2011-01-01

    Closed humeral nailing is now considered an alternative treatment for humeral-shaft fracture. The nail can be inserted with either the antegrade or retrograde method. We investigated and compared the problem of geometric mismatch of the humeral nail to the humerus between the two methods of insertion. The study was performed using virtual simulation based on computed tomography (CT) data of 76 Thai cadaveric humeri and the commonly used Russell-Taylor humeral nail 8 mm in diameter and 220 mm long. Mismatch of the nail to the intact humerus was analyzed and compared between the antegrade and retrograde nailing approaches. The results showed: the diameter of the medullary canal averaged 7.9-13.8 mm; the minimal reaming diameter to accommodate virtual nail insertion averaged 8.8-14.8 mm for the antegrade and 8.8-29.3 mm for the retrograde approach; the minimal reaming thickness of the inner cortex averaged 0.1-1.5 mm for the antegrade and 0.1-9.9 mm for the retrograde approach; the percentages of cortical bone removed prior to nail insertion were 3.8-107.1% and 3.8-1,287.6% for the antegrade and retrograde approaches, respectively; the eccentricity of the nail-medullary canal center were 0.4-3.4 and 0.4-10.6 mm for the antegrade and retrograde approaches, respectively. Less mismatching occurred with antegrade nailing than with the retrograde approach. Retrograde nailing requires excessive reaming at the distal part of the humerus to accommodate nail insertion. This may create bone weakness and the risk of supracondylar fracture. (author)

  20. Nail psoriasis masqueraded by secondary infection with Rhodotorula mucilaginosa.

    Science.gov (United States)

    Martini, K; Müller, H; Huemer, H P; Höpfl, R

    2013-11-01

    A 38-year-old man presented with whitish nail changes on all fingers as the sole symptom. The condition had developed within a few days and led to dystrophy of the proximal part of the nail plates. As microscopic examination of nail scrapings demonstrated budding hyphae and the patient working as a teacher reported frequent use of a wet sponge, antifungal therapy was initiated. Subsequent cultures and molecular typing identified Rhodotorula mucilaginosa (formerly R. rubra). This environmental yeast was repeatedly isolated despite of therapy with itraconazole. As no improvement was achieved and testing of the biological activity of the fungus revealed only marginal keratolytic activity, it was considered as a coloniser of a destructed nail matrix. Finally, a biopsy of the nail bed confirmed the diagnosis of nail psoriasis, which rapidly responded to treatment with acitretin and topical calcipotriol/betamethasone cream. Fungal growth in destructed nails masqueraded the underlying disease and may have triggered the psoriatic nail reaction. © 2013 Blackwell Verlag GmbH.

  1. Nails in Forensic Toxicology: An Update.

    Science.gov (United States)

    Solimini, Renata; Minutillo, Adele; Kyriakou, Chrystalla; Pichini, Simona; Pacifici, Roberta; Busardo, Francesco Paolo

    2017-01-01

    The analysis of nails as a keratinized matrix to detect drugs or illicit substances has been increasingly used in forensic and clinical toxicology as a complementary test, especially for the specific characteristics of stably accumulating substances for long periods of time. This allows a retrospective investigation of chronic drug abuse, monitoring continuous drug or pharmaceutical use, reveal in utero drug exposure or environmental exposures. We herein review the recent literature investigating drug incorporation mechanisms and drug detection in nails for forensic toxicological purposes. Mechanisms of drug incorporation have not yet been fully elucidated. However, some research has lately contributed to a better understanding of how substances are incorporated into nails, suggesting three potential mechanisms of drug incorporation: contamination from sweat, incorporation from nail bed and incorporation from germinal matrix. In addition, numerous methods dealing with the determination of drugs of abuse, medications and alcohol biomarkers in nails have been reported in studies over the years. The latter methods could find application in clinical and forensic toxicology. The studies herein reviewed point out how important it is to standardize and harmonize the methodologies (either pre-analytical or analytical) for nails analysis and the optimization of sampling as well as the development of proficiency testing programs and the determination of cut-off values. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  2. Heat profiles of laser-irradiated nails.

    Science.gov (United States)

    Paasch, Uwe; Nenoff, Pietro; Seitz, Anna-Theresa; Wagner, Justinus A; Kendler, Michael; Simon, Jan C; Grunewald, Sonja

    2014-01-01

    Onychomycosis is a worldwide problem with no tendency for self-healing, and existing systemic treatments achieve disease-free nails in only 35 to 76% of cases. Recently, treatment of nail fungus with a near-infrared laser has been introduced. It is assumed that fungal eradication is mediated by local heat. To investigate if laser treatment has the potential to eradicate fungal hyphae and arthrospores, laser heat application and propagation needs to be studied in detail. This study aimed to measure nail temperatures using real-time videothermography during laser irradiation. Treatment was performed using 808- and 980-nm linear scanning diode lasers developed for hair removal, enabling contact-free homogeneous irradiation of a human nail plate in one pass. Average and peak temperatures increased pass by pass, while the laser beam moved along the nail plates. The achieved mean peak temperatures (808 nm: 74.1 to 112.4°C, 980 nm: 45.8 to 53.5°C), as well as the elevation of average temperatures (808 nm: 29.5 to 38.2°C, 980 nm: 27.1 to 32.6°C) were associated with pain that was equivalent to that of hair removal procedures and was not significantly different for various wavelengths. The linear scanning laser devices provide the benefits of contact-free homogeneous heating of the human nail while ensuring adequate temperature rises.

  3. Clinical features and nail clippings in 52 children with psoriasis.

    Science.gov (United States)

    Uber, Marjorie; Carvalho, Vânia O; Abagge, Kerstin T; Robl Imoto, Renata; Werner, Betina

    2018-03-01

    Nail clipping, the act of cutting the distal portion of a nail for microscopic analysis, can complement the diagnosis of skin diseases with nail involvement, such as psoriasis. This study aimed to describe histopathologic findings on 81 nails from 52 children and adolescents with skin psoriasis and to determine whether these changes correlated with the severity of skin and nail involvement. Children with psoriasis were enrolled in this cross-sectional study to obtain Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores. The most altered nails were processed using periodic acid-Schiff with diastase staining. Fifty-two patients with a median age of 10.5 years were included. The median Nail Psoriasis Severity Index score of the 20 nails from these patients was 17 (range 3-80). The most common findings were pitting (94.2%), leukonychia (73.0%), and longitudinal ridges (63.5%). Eighty-one nail fragments were collected by clipping. Neutrophils were found in 6 samples (7.6%) and serous lakes in 15 (19%). Median nail plate thickness was 0.3 mm (range 0.1-0.63 mm). Patients whose nails had neutrophils had a higher median PASI score (6.1 vs 2.0, P = .03). Patients whose nails had serous lakes had higher median PASI (5.3 vs 1.9, P = .008) and NAPSI (median 45.0 vs 18.0, P = .006) scores. There seems to be a correlation between some microscopic nail features in children with psoriasis and their PASI and NAPSI scores, so nail clippings from children with suspected psoriasis may help with diagnosis, especially in the presence of neutrophils, and in excluding onychomycosis. © 2018 Wiley Periodicals, Inc.

  4. Nickel in nails, hair and plasma from nickel-hypersensitive women

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Veien, Niels

    1990-01-01

    The concentrations of nickel in finger-nails, toe-nails, hair and plasma from 71 nickel-hypersensitive women and 20 non-hypersensitive women were determined. Nickel concentrations in finger-nails were significantly higher than in toe-nails in both the nickel-hypersensitive group and the control...... group. Nickel-sensitive women had significantly higher levels of nickel in toe-nails, hair and plasma than had control subjects, whereas there was no significant difference in nickel concentration in finger-nails between the two groups. No correlation could be demonstrated between nickel levels in any...... combination of nails, hair and plasma in the nickel-hypersensitive or in the control group....

  5. Nail disorders in children, a clinical study

    Directory of Open Access Journals (Sweden)

    Ayşe Akbaş

    2016-04-01

    Full Text Available Introduction: Aims of the study to investigate the frequency and the nature ofnail disorders in children significant clinical data is available. Nail disorders although common in children in some parts of our country. This study was carried out to document the clinical and demographic pattern of nail disorders in a dermatology outpatient clinic of a pediatric hospital in Ankara, Turkey. Material and Methods: All consecutive patients a total of 3000 children from age 0-16 were admitted to dermatology outpatient clinic of Ankara Pediatric Hematology and Oncology Education and Research Hospital during January 2011 to December 2011 were studied and retrospectively evaluated for age, gender, drug use, diseases, systemic or genetic disorders and demographic features. Diagnostic evaluation results were noted and patients were categorized for demographic features and diagnosis. Results: These 133 patients (M: F 58:75, %44 vs 56, respectively were under 16 years of age and have 17 different dermatological disorders related with nail symptoms. Fifty three of (39,8% these patient were under 2 years of age, 31 (23.3% were between 3-5 years, 30 (22.5% were between 6-11 years old, 19 of 133 (14%, 2 were between 11-16 years of age. Through all of ages and independent of gender the most etiologies of nail disorders were, onychomadesis, paronychia, onycholysis, onychomycosis and systemic nail presentation of systemic dermatosis. Conclusion: Nail disorders are different in children than in adults. In our study, the first 5 years of age was found in 53% of nail disorders. Nail disorders are uncommon but may be seen as a part of a systemic disease and may be associated with cosmetic and psychologic problem.

  6. NAIL SAMPLING TECHNIQUE AND ITS INTERPRETATION

    Directory of Open Access Journals (Sweden)

    TZAR MN

    2011-01-01

    Full Text Available The clinical suspicion of onychomyosis based on appearance of the nails, requires culture for confirmation. This is because treatment requires prolonged use of systemic agents which may cause side effects. One of the common problems encountered is improper nail sampling technique which results in loss of essential information. The unfamiliar terminologies used in reporting culture results may intimidate physicians resulting in misinterpretation and hamper treatment decision. This article provides a simple guide on nail sampling technique and the interpretation of culture results.

  7. Nail Psoriasis: A Review of Treatment Options.

    Science.gov (United States)

    Pasch, Marcel C

    2016-04-01

    Nail involvement affects 80-90 % of patients with plaque psoriasis, and is even more prevalent in patients with psoriatic arthritis. This review is the result of a systemic approach to the literature and covers topical, intralesional, conventional systemic, and biologic systemic treatments, as well as non-pharmacological treatment options for nail psoriasis. The available evidence suggests that all anti-tumor necrosis factor-α, anti-interleukin (IL)-17, and anti-IL-12/23 antibodies which are available for plaque psoriasis and psoriatic arthritis are highly effective treatments for nail psoriasis. Conventional systemic treatments, including methotrexate, cyclosporine, acitretin, and apremilast, as well as intralesional corticosteroids, can also be effective treatments for nail psoriasis. Topical treatments, including corticosteroids, calcipotriol, tacrolimus, and tazarotene, have also been shown to have a position in the treatment of nail psoriasis, particularly in mild cases. Finally, non-pharmacological treatment options, including phototherapy, photodynamic therapy, laser therapy, and several radiotherapeutic options, are also reviewed but cannot be advised as first-line treatment options. Another conclusion of this review is that the lack of a reliable core set of outcomes measures for trials in nail psoriasis hinders the interpretation of results, and is urgently needed.

  8. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... your head About nails: More important than you think Questions lots of kids ask about their skin, ... habit with a good habit: When you feel like biting your nails, try playing with a stress ...

  9. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... figure out how to avoid these situations and develop a plan to stop. Just knowing when you’ ... a doctor. If you bite your nails and develop a skin or nail infection, consult a board- ...

  10. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... your fingers and from your nails to your face and mouth. To help you stop biting your ... re inclined to bite may help solve the problem. Try to gradually stop biting your nails: Some ...

  11. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... and nails Skin dictionary Camp Discovery Good Skin Knowledge lesson plans and activities Video library Find a ... counter, this safe, but awful-tasting formula discourages many people from biting their nails. Get regular manicures: ...

  12. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... your nails to your face and mouth. To help you stop biting your nails, dermatologists recommend the ... stress ball or silly putty instead. This will help keep your hands busy and away from your ...

  13. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... biting can make the skin around your nails feel sore, and it can damage the tissue that ... biting habit with a good habit: When you feel like biting your nails, try playing with a ...

  14. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... care / hair loss Injured skin Nail care Anti-aging skin care Kids’ zone About skin: Your body's ... biting Nail changes a dermatologist should examine Anti-aging skin care Kids’ zone Video library Find a ...

  15. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... Injured skin Nail care Anti-aging skin care Kids’ zone About skin: Your body's largest organ About ... More important than you think Questions lots of kids ask about their skin, hair, and nails. Amazing ...

  16. Comparative study between lateral decubitus and traction table for treatment of pertrochanteric fractures with cephalomedullary nails

    Directory of Open Access Journals (Sweden)

    Eric Fernando de Souza

    Full Text Available ABSTRACT OBJECTIVE: To perform a retrospective radiographic assessment of the reduction and implant position in the femoral head in patients with pertrochanteric fractures treated with cephalomedullary nailing in the lateral position versus traction table. METHODS: Radiographs of patients with pertrochanteric fracture of the femur treated with cephalomedullary nailing in the lateral position and traction table were retrospectively evaluated. For the evaluation we used the anteroposterior radiographic view of the pelvis and the lateral view of the affected side. The cervicodiaphyseal angle, the tip-apex distance (TAD, and the spatial position of the cephalic component in the head were measured. Two patient groups were created, one group operated on the traction table and another group operated in the lateral position. RESULTS: Regarding the cervicodiaphyseal angle observed in the traction table group, the results of 11 patients (61.1% were outside the acceptable parameters proposed in the present study. Both groups were equivalent regarding TAD and the position of the cephalic component in the head. CONCLUSION: A difference in the cervicodiaphyseal angle was observed; the group operated on the traction table had 11 patients (61.1% whose measurements were outside the acceptable parameters.

  17. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... and Lectureship Clarence S. Livingood Award and Lectureship Marion B. Sulzberger Award and Lectureship Master Dermatologist Award Members ... care Nail care Nail biting "); (function () { var a = "", b = [ "adid=aad-aad-1", "site=ehs.con.aad. ...

  18. Despite the hair failing, nails thrive…

    Directory of Open Access Journals (Sweden)

    Samipa Samir Mukherjee

    2017-01-01

    Full Text Available Ectodermal dysplasias are defined as a group of congenital, nonprogressive, developmental syndromes with primary disorders in at least two ectoderm-derived structures namely eccrine glands, hair, nail and teeth. Pure hair and nail affecting ectodemal dysplasias are exceedingly rare in occurance and have been known to be associated with multiple abnormalities, such as keratoderma or ichthyosis, skeletal and hematological abnormalities, cardiac irregularities, mental or psychomotor retardation and cataracts. We herein report a case of hypotrichosis with trichorrhexis nodosa and twenty nail dystrophy- a hypohidrotic ectodermal dysplasia variant.

  19. How to Stop Biting Your Nails

    Medline Plus

    Full Text Available ... Resident International Grant Resident Scholarship to Legislative Conference Skin Care for Developing Countries Grant State Advocacy Grant Strauss ... A-Z index Skin, hair, and nail care Skin care Hair care / hair loss Injured skin Nail care ...

  20. Guidance on maintaining personal hygiene in nail care.

    Science.gov (United States)

    Malkin, Bridget; Berridge, Pat

    Nail care is important in the maintenance of personal hygiene and is an essential aspect of patient care. Confusion about who should perform nail care for patients has resulted in poor practice and cycles of non-activity. This article provides guidance for nurses on performing routine nail care.

  1. Neurobrucellosis presenting as an intra-medullary spinal cord abscess

    Directory of Open Access Journals (Sweden)

    Patil Chidanand S

    2005-09-01

    Full Text Available Abstract Background Of the diverse presentation of neurobrucellosis, intra-medullary spinal cord abscess is extremely rare. Only four other cases have been reported so far. We present a case of spinal cord intra-medullary abscess due to Brucella melitensis. Case presentation A forty-year-old female presented with progressive weakness of both lower limb with urinary incontinence of 6 months duration. She was febrile. Neurological examination revealed flaccid areflexic paraplegia with T10 below sensory impairment including perianal region. An intramedullary mass was diagnosed on Magnetic Resonance Image (MRI scan extending from T12 to L2. At surgery, a large abscess was encountered at the conus medullaris, from which Brucella melitensis was grown on culture. She was started on streptomycin and doxycycline for 1 month, followed by rifampicin and doxycycline for 1 month. At 2-year follow-up, she had recovered only partially and continued to have impaired bladder function. Conclusion Neurobrucellosis, if not treated early, can result in severe neurological morbidity and sequale, which may be irreversible. Hence it is important to consider the possibility of neurobrucellosis in endemic region and treat aggressively.

  2. Nail psoriasis: a questionnaire-based survey

    NARCIS (Netherlands)

    Klaassen, K.M.G.; Kerkhof, P.C.M. van de; Pasch, M.C.

    2013-01-01

    BACKGROUND: Skin manifestations are the most characteristic finding of psoriasis. However, nail involvement is also a clinical feature of disease although it is often overlooked. The documented prevalence of nail psoriasis varies between 10.0% and 81.1%. OBJECTIVES: The aim of this investigation is

  3. [Are nail polish, artificial nails and piercings allowed outside the surgical area?Recommendations for the perioperative policy

    NARCIS (Netherlands)

    Bucx, M.J.L.; Krijtenburg, P.; Scheffer, G.J.

    2017-01-01

    - An increasing number of patients wear nail polish, artificial nails or have piercings.- There is uncertainty about the perioperative management of these items, especially when located outside the surgical area.- In the majority of hospitals, patients are urged to remove these items preoperatively,

  4. [Are nail polish, artificial nails and piercings allowed outside the surgical area?Recommendations for the perioperative policy].

    Science.gov (United States)

    Bucx, M J L; Krijtenburg, P; Scheffer, G J

    2017-01-01

    - An increasing number of patients wear nail polish, artificial nails or have piercings.- There is uncertainty about the perioperative management of these items, especially when located outside the surgical area.- In the majority of hospitals, patients are urged to remove these items preoperatively, under the assumption that they might cause problems.- Frequently, however, these items cannot be removed straightforwardly.- Nail polish and artificial nails only very rarely cause perioperative problems and therefore do not need to be removed pre-operatively.- The same applies to most piercings, except when located in or near the respiratory tract, if they have sharp endings or if they might cause problems as a result of the perioperative positioning of the patient.- Providing adequate information to the patient, knowledge about removal of these items and documentation of agreed arrangements are all important.- A national guideline concerning perioperative policy is urgently required.

  5. Nail Changes in End-Stage Renal Failure Patients on Hemodialysis

    Directory of Open Access Journals (Sweden)

    Jamal Arshad

    2000-01-01

    Full Text Available To evaluate the fingernail changes in patients with end-stage renal failure (ESRF on regular hemodialysis (HD, we reviewed 69 patients (male 25, female 44; age 40 ± 14.8 years who have been on HD at Samtah General Hospital, Gizan, Kingdom of Saudi Arabia for a mean of 4.3 ± 3.06 years. They were free from congenital, systemic or primary skin disorders contributing to nail changes. The patients were also free from ornamental dyes like henna, traumatic injuries or infections in the fingernails. They were also clinically free from features suggestive of the carpal tunnel syndrome or vascular steal syndrome secondary to arteriovenous fistula (AVF created for vascular access. Their nails were examined under bright day light by the authors independently. The findings consistent among all three observers were taken for analysis. Hemoglobin and serum albumin levels were also estimated. We compared these changes according to age, sex, and duration on chronic hemodialysis, AVF, and the levels of serum albumin and hemoglobin. One or more nail changes were observed in 44/69 (64% patients. The commonest abnormality was the so-called "Half-and-half nail changes", which was observed in the finger nails of 18/69 (26% of the study patients (males to female ratio was 2:1. Typically, the half-and-half nails are nails where the distal portion of the nail bed is red, pink or brown, occupies 20-60% of the total nail length and is always sharply demarcated with the proximal portion. The latter has a dull whitish ground glass appearance and when pressure is applied, the distal discoloration does not fade completely. Non-specific nail changes were observed 26/69 (38% patients. The hemoglobin and serum albumin levels were not significantly different of those with ′half-and-half′ nail, non-specific nail changes or no nail changes. We conclude that various fingernail changes are observed in ESRF patients on HD. These nail changes are independent of the age of the

  6. [Intramedullary stabilisation of displaced midshaft clavicular fractures: does the fracture pattern (simple vs. complex) influence the anatomic and functional result].

    Science.gov (United States)

    Langenhan, R; Reimers, N; Probst, A

    2014-12-01

    Displaced midshaft clavicular fractures are often treated operatively. The most common way of treatment is plating. Elastic stable intramedullary nailing (ESIN) is an alternative, but seldom used. Studies showed comparable or even better results for intramedullary nailing than for plating in simple 2- or 3-fragment midshaft fractures. The indication of ESIN for multifragmentary clavicular fractures is discussed critically in the literature because of reduced primary stability and danger of secondary shortening. Until now only few studies report functional results after fracture healing depending on the fracture type. To the best of our knowledge there is no study showing significantly worse functional scores for ESIN in complex displaced midshaft fractures. The objective of this study was to examine anatomic and functional results of simple (2 or 3 fragments, OTA type 15B1 and 15B2) and complex (multifragmentary, OTA type 15B3) displaced midshaft clavicula fractures after internal fixation. Between 2009 and 2012, 40 patients (female/male 10/30; mean age 33 [16-60] years) with closed displaced midshaft clavicular fractures were treated by open reduction and ESIN (Titanium Elastic Nail [TEN], Synthes, Umkirch, Germany). Thirty-seven patients were retrospectively analysed after a mean of 27 (12-43) months. Twenty patients (group A) had simple fractures (OTA type 15B1 and 15B2), 17 patients (group B) had complex fractures (OTA type 15B3). All shoulder joints were postoperatively treated functionally for six weeks without weight limited to 90° abduction/flexion. Both groups were comparable in gender, age, body mass index, months until metal removal, number of physiotherapy sessions and time until follow-up examination. Joint function (neutral zero method) and strength (standing patient with arm in 90° abduction, holding 1-12 kg for 5 sec) in both shoulders were documented. The distance between the centre of the jugulum and the lateral acromial border was measured for

  7. Sarcoidosis: radiographic manifestations in the nails and distal phalanges

    Energy Technology Data Exchange (ETDEWEB)

    Albers, Brittany K.; Garner, Hillary W. [Mayo Clinic, Department of Radiology, Jacksonville, FL (United States); Sluzevich, Jason C. [Mayo Clinic, Department of Dermatology, Jacksonville, FL (United States)

    2016-05-15

    Sarcoidosis is a granulomatous disease which can affect multiple organ systems. Clinical and radiologic manifestations depend on the organ system involved and the chronicity of disease. Nail involvement in sarcoidosis is rare, but is clinically relevant as it indicates chronic systemic disease. Nail abnormalities can be identified radiographically, and when seen in patients with known or suspected sarcoidosis, should prompt careful evaluation of the underlying bone for osseous involvement. We describe a case of sarcoidosis with radiographic findings in the nails and distal phalangeal tufts, which were indicative of nail and osseous sarcoid involvement and strongly supported the presence of chronic systemic disease. Although the nail findings resolved clinically and on radiographs after treatment, the osseous findings showed only minimal improvement. To our knowledge, the radiographic findings of nail sarcoidosis have not been previously addressed in the literature. (orig.)

  8. Sarcoidosis: radiographic manifestations in the nails and distal phalanges

    International Nuclear Information System (INIS)

    Albers, Brittany K.; Garner, Hillary W.; Sluzevich, Jason C.

    2016-01-01

    Sarcoidosis is a granulomatous disease which can affect multiple organ systems. Clinical and radiologic manifestations depend on the organ system involved and the chronicity of disease. Nail involvement in sarcoidosis is rare, but is clinically relevant as it indicates chronic systemic disease. Nail abnormalities can be identified radiographically, and when seen in patients with known or suspected sarcoidosis, should prompt careful evaluation of the underlying bone for osseous involvement. We describe a case of sarcoidosis with radiographic findings in the nails and distal phalangeal tufts, which were indicative of nail and osseous sarcoid involvement and strongly supported the presence of chronic systemic disease. Although the nail findings resolved clinically and on radiographs after treatment, the osseous findings showed only minimal improvement. To our knowledge, the radiographic findings of nail sarcoidosis have not been previously addressed in the literature. (orig.)

  9. Stiffness Analysis of Nail-Plate Joints Subjected to Short-Term Loads

    DEFF Research Database (Denmark)

    Nielsen, Jacob

    nail-plates are designed for trusses. For many years, joints were made of boards with nails, but the increasing industrialism and the need for quick and usable assembly had the result that today nearly all trusses are pre-fabricated with nail-plates. The word "nail-plate" has been used for different...... types of plates. There are two main types of nail-plates: steel plates perforated with holes in which separate nails are used and steel plates perforated by a stamping machine, so the nails are made from the plate, see figur 1.2 on page 7. This type is sometimes called "punching metal plate...

  10. How evolution of the nailing system improves results and reduces orthopedic complications: more than 2000 cases of trochanteric fractures treated with the Gamma Nail System.

    Science.gov (United States)

    Pascarella, R; Fantasia, R; Maresca, A; Bettuzzi, C; Amendola, L; Violini, S; Cuoghi, F; Sangiovanni, P; Cerbasi, S; Boriani, S; Tigani, D S

    2016-04-01

    The incidence of trochanteric fractures has increased significantly during the last few decades, especially in elderly patients with osteoporosis. The dynamic/sliding hip screw and the cephalomedullary nail are the most commonly used fixation methods to treat trochanteric fractures. The improvements in the Gamma Nail System (GNS) associated with a correct surgical technique reduced the postoperative orthopedic complications. The purpose of this study was to compare the results of the different Gamma Nails. The present study is a retrospective analysis of 2144 patients treated with GNS between January 1997 and December 2011 for trochanteric fractures, classified according to AO classification method. The patients were divided into three groups according to the nailing system: 525 were treated with Standard Gamma Nail (SGN), 422 with Trochanteric Gamma Nail (TGN) and 1197 with Gamma3 Nail. The overall incidence of intra-operative complications was 1.21 %; the incidence of intra-operative complications for each group was 1.71 % for SGN group, 0.47 % for TGN group and 1.25 % for Gamma3 Nail group. The overall incidence of postoperative complications was 5.48 %, and the incidence for each group was 10.73 % for SGN group, 9.92 % for TGN group and 2.92 % for Gamma3 Nail group. The GNS is a safe device with a low rate of intra-operative complications. The evolution of this nail system reduces postoperative complications, thus improving the results at follow-up and confirming that the Gamma3 Nail is a safe and predictable device to fix trochanteric fracture.

  11. Nail changes in alopecia areata: Incidence and pattern

    Directory of Open Access Journals (Sweden)

    Gandhi V

    2003-03-01

    Full Text Available One hundred consecutive patients with alopecia areata were examined for presence of nail abnormalities. Nail changes were seen in 44/100 (44% of patients with most frequent occurrence in multifocal variety (30/44=68%. The commonest abnormality observed was superficial pits seen in 28(64% patients. Presence and severity of nail changes may indicate a more severe and recalcitrant disease.

  12. MR imaging of intramedullary ischemia due to cervical spondylosis

    International Nuclear Information System (INIS)

    Dooms, G.; Mathurin, P.; Cornelis, G.; Hulcelle, P.

    1988-01-01

    A retrospective study was performed to assess the value of MR imaging for detecting intramedullary ischemia due to cervical spondylosis and to assess its clinical significance. One hundred consecutive unselected patients (70 men and 30 women, mean age = 62 years) were included in the study. All patients were treated surgically, either by anterior diskectomy and corporectomy or by posterior laminectomy. Clinical follow-up to 2 years was available for every patient. MR imaging was performed with a superconducting magnet (Philips Gyroscan S15) operating at 1.5T Sagittal T1-weighted (repetition time [TR] = 0.45 sec and echo time [TE] = 30 msec) and cardiac-gated T2-weighted (TR>1.2 sec and multiples TE of 50, 100 and 200 msc) imaging was performed in every patient. Cervical spondylosis was exquisitely demonstrated on MR images in every patient. With the sagittal plane, full extent and the degree of canalar stenosis were easily appreciated on T2-weighted images. A hyperintense intramedullary lesion was detected preoperatively in 24 of the patients and corresponded presumably to ischemic, edematous, and/or necrotic damage to the cord. It was usually located at the level or just below the level where the most severe canalar stenosis was demonstrated; it was identified only on T2-weighted images. In a comparison of the clinical outcome of the patients after surgery, there was a striking difference between the group of patients without and that with intramedullary lesions. In the first group, the relief of symptoms after surgery was partial or complete. In the other group, the clinical outcome was poor and symptom relief nearly absent. In conclusion, MR imaging is an exquisite modality for demonstrating necrotic intramedullary changes due to cervical spondylosis and thus may aid in determining the prognosis for surgery and clinical outcome of the patients

  13. High-resolution ultrasonography in assessment of nail-related disorders.

    Science.gov (United States)

    Singh, R; Bryson, D; Singh, H P; Jeyapalan, K; Dias, J J

    2012-09-01

    Disorders of the nail can pose a diagnostic challenge, and non-invasive imaging is frequently required to clarify diagnosis and delineate anatomy pre-operatively. We explored the use of high-resolution ultrasonography in the assessment of patients with nail disorders attending orthopaedic hand clinics. A search of a university teaching hospital musculoskeletal radiology database identified 36 patients (mean age 54.2 years) where ultrasonography was used to assess nail-related disorders between April 2003 and January 2007. Clinical, surgical and histological findings were correlated in these cases with ultrasound reports. Ultrasound findings correlated with the provisional diagnosis in 20 (61%) of 33 patients and provided a diagnosis in 3 patients where a provisional diagnosis was unavailable. In 7 of the 13 cases where the clinical diagnosis differed from ultrasound findings, a lump originally diagnosed as cystic in origin was shown to be solid on ultrasound. Different nail pathologies showed different characteristics on ultrasonography, including differences in vascularity, echogenicity, changes in nail structure/shape and extension into the nail bed, matrix, fold or evidence of bony erosion. The ultrasound findings correlated with histological analysis and intra-operative assessment in 10 of 15 patients who underwent operative treatment. Ultrasound provides important information on the anatomy of the nail apparatus and can differentiate solid and cystic lesions. It can be used as a diagnostic tool and can therefore help in pre-operative planning of nail-related disorders. In our series ultrasound supported or improved upon the clinical diagnosis in 31 (86%) out of the 36 patients presenting with nail-related disorders.

  14. Intramedullary cavernous angiomas of the spinal cord. Clinical characteristics of 13 lesions

    International Nuclear Information System (INIS)

    Aoyama, Takeshi; Hida, Kazutoshi; Houkin, Kiyohiro

    2011-01-01

    Magnetic resonance imaging has increased the incidence of the diagnosis of intramedullary cavernous angioma. Surgical therapy tends not to be recommended for asymptomatic lesions, but symptomatic lesions that bleed recurrently should be treated. The natural course of intramedullary cavernous angioma remains unknown and arguments have been raised against the surgical treatment of symptomatic lesions. We reviewed the clinical features of 13 intramedullary cavernous angiomas in 12 patients surgically treated between 1988 and 2009. The 7 men and 5 women were aged from 14 to 60 years, the preoperative interval ranged from 0 to 161 months, and the mean number of hemorrhages in the 13 lesions was 2.5. Sixteen operations were performed to treat the 13 lesions. The surgical approach depended on the lesion location. The outcome of patients with mild to moderate preoperative symptoms (McCormick grades I-III) was significantly better than that of patients with severe symptoms (McCormick grade IV) (p<0.05). Symptomatic intramedullary cavernous angioma tends to bleed repeatedly. The lesion should be surgically removed to avoid further deterioration due to recurrent hemorrhages. The shortest path approach should be selected based on preoperative images and complete removal should be attempted. Residual lesion may be masked by surrounding gliosis, so careful postoperative follow up is necessary. (author)

  15. A novel surgical method for total nail ablation: Use of triple flap technique

    Directory of Open Access Journals (Sweden)

    Berna Aksoy

    2017-11-01

    Full Text Available Total nail ablation for the treatment of onychodystrophies can be performed by using chemicals, surgical resection or laser ablation of nail matrix. A female patient with bilateral severe onychodystrophy as a result of inadvertent previous nail surgeries was treated surgically. Proximal complete nail matrix resection and distal 10 mm wide transverse strip partial nail bed resection were performed. A 5 mm wide transverse strip of nail bed was left intact proximally. Proximal nail matrix defect was closed by using the skin of proximal nail fold. The distal nail bed defect was reconstructed by using triple flap technique which was composed of a main central advancement flap containing ventral toe skin and two side flaps containing nail fold skin. The patient healed without any problem and her nail problem was treated successfully. The cosmetic appearance of her first toes was acceptable. Surgical nail ablation followed by volar skin coverage of dorsal surface of the distal phalanx bone by using triple flap technique is an effective surgical treatment method for the correction of advanced nail plate deformities requiring total nail ablation. 

  16. Intramedullary Recurrence of a Thoracic Meningioma-Presentation of an Unusual Case and Review of the Literature.

    Science.gov (United States)

    Piazza, Matthew A; Ramayya, Ashwin G; Geiger, Geoffrey A; Alonso-Basanta, Michelle; Nasrallah, MacLean P; Welch, William C; Ozturk, Ali K

    2016-08-01

    Spinal meningiomas are typically extra-axial, slow-growing, benign tumors that arise from the arachnoid cap cells. Intramedullary spinal meningiomas are exceedingly rare with few cases reported in the literature. A 64-year-old man with a history of grade I thoracic meningioma at the T4 level resected initially in 1989 and who required reoperation in 2013 for intradural, extramedullary recurrence of tumor presented again in 2015 with gait difficulty. Magnetic resonance imaging revealed a soft tissue mass at the T3 to T4 levels on the left side of the canal that was mildly enhancing on T1 contrasted sequences. The patient was taken to the operating room, where a purely intramedullary recurrence was discovered without extramedullary extension or a dural-based attachment. The intramedullary tumor was completely resected, and postoperatively the patient recovered well and was at his neurologic baseline. The patient ultimately underwent proton beam radiotherapy because this tumor, although benign, had recurred twice. Intramedullary spinal meningiomas, particularly intramedullary low-grade recurrence of a previously extramedullary tumor, are rare phenomena. Although the pathogenic mechanisms are not well understood, intramedullary recurrence as described in this patient may reflect extrinsic factors related to prior surgical resections in addition to histologic progression. When operating on recurrent extramedullary lesions, aggressive arachnoid dissection may predispose patients to unusual patterns of recurrence. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. [A favourable outcome in yellow nail syndrome: role of respiratory physiotherapy].

    Science.gov (United States)

    Fournier, C; Just, N; Leroy, S; Wallaert, B

    2003-12-01

    The yellow nail syndrome is a rare condition that is easily diagnosed but the nail manifestations are poorly understood. A 51 year old patient presented with a chronic cough. The diagnosis was based on the typical appearance of the nails. The patient had bilateral basal bronchiectasis. Daily physiotherapy with bronchial drainage lead to a progressive improvement in the respiratory symptoms without recourse to antibiotics. Surprisingly the abnormalities of the nails disappeared after 2 years treatment. This observation illustrates the possibility of spontaneous resolution of severe nail abnormalities during the course of the yellow nail syndrome.

  18. An investigation into UV-curable gel formulations for topical nail medicines

    OpenAIRE

    Kerai, L. V.

    2016-01-01

    UV gels are nail cosmetics which are applied on the nail plate surface and polymerised by placing the nail under a UVA nail lamp. The polymeric film formed can reside on the nail plate for up to 3 weeks without developing any visible defects. Using such a formulation as a drug carrier for the treatment of nail diseases, e.g. fungal infections, could address current issues with topical formulations, such as the failure to maintain a drug depot at the desired site and the need for frequent appl...

  19. Biomechanical Comparison of an Intramedullary and Extramedullary Free-Tissue Graft Reconstruction of the Acromioclavicular Joint Complex

    Science.gov (United States)

    Garg, Rishi; Javidan, Pooya; Lee, Thay Q.

    2013-01-01

    Background Several different surgical techniques have been described to address the coracoclavicular (CC) ligaments in acromioclavicular (AC) joint injuries. However, very few techniques focus on reconstructing the AC ligaments, despite its importance in providing stability. The purpose of our study was to compare the biomechanical properties of two free-tissue graft techniques that reconstruct both the AC and CC ligaments in cadaveric shoulders, one with an extramedullary AC reconstruction and the other with an intramedullary AC reconstruction. We hypothesized intramedullary AC reconstruction will provide greater anteroposterior translational stability and improved load to failure characteristics than an extramedullary technique. Methods Six matched cadaveric shoulders underwent translational testing at 10 N and 15 N in the anteroposterior and superoinferior directions, under AC joint compression loads of 10 N, 20 N, and 30 N. After the AC and CC ligaments were transected, one of the specimens was randomly assigned the intramedullary free-tissue graft reconstruction while its matched pair received the extramedullary graft reconstruction. Both reconstructed specimens then underwent repeat translational testing, followed by load to failure testing, via superior clavicle distraction, at a rate of 50 mm/min. Results Intramedullary reconstruction provided significantly greater translational stability in the anteroposterior direction than the extramedullary technique for four of six loading conditions (p < 0.05). There were no significant differences in translational stability in the superoinferior direction for any loading condition. The intramedullary reconstructed specimens demonstrated improved load to failure characteristics with the intramedullary reconstruction having a lower deformation at yield and a higher ultimate load than the extramedullary reconstruction (p < 0.05). Conclusions Intramedullary reconstruction of the AC joint provides greater stability in the

  20. Nail bed expansion: A new technique for correction of multiple isolated congenital micronychia

    Directory of Open Access Journals (Sweden)

    Gholamhossein Ghaffarpour

    2014-01-01

    Full Text Available Congenital micronychia may involve big toes or may involve other nails. The etiology of micronychia is not clear but amniotic bands, teratogens (drugs, alcohol, Nail Patella Syndrome etc. A 44-year-old woman with multiple isolated congenital micronychia over her hands and feet was selected. The major affected nails were thumbs and Index fingers. Surgical method were done step by step: Anesthesia of the area, extraction of short nail, elevation of nail bed, longitudinal nail bed incisions, suturing the lateral nail bed to the nail wall, covering the nail bed by a splint of plastic suction tube, bandage with gauze Vaseline. Finally, we hypnotized that in congenital micronychia, the main pathology is in nail bed; through this theory by nail bed expansion better outcomes are coming.

  1. Drug delivery into microneedle-porated nails from nanoparticle reservoirs.

    Science.gov (United States)

    Chiu, Wing Sin; Belsey, Natalie A; Garrett, Natalie L; Moger, Julian; Price, Gareth J; Delgado-Charro, M Begoña; Guy, Richard H

    2015-12-28

    This study demonstrates the potential of polymeric nanoparticles as drug reservoirs for sustained topical drug delivery into microneedle-treated human nail. Laser scanning confocal microscopy was used to image the delivery of a fluorescent model compound from nanoparticles into the nail. A label-free imaging technique, stimulated Raman scattering microscopy, was applied, in conjunction with two-photon fluorescence imaging, to probe the disposition of nanoparticles and an associated lipophilic 'active' in a microneedle-porated nail. The results provide clear evidence that the nanoparticles function as immobile reservoirs, sequestered on the nail surface and in the microneedle-generated pores, from which the active payload can be released and diffuse laterally into the nail over an extended period of time. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Itching for nail fashion: chronic urticaria and chronic hand dermatitis secondary to acrylate and methacrylate allergy in gel nail varnish.

    Science.gov (United States)

    Dickison, P; Smith, S D

    2018-01-01

    Allergic contact dermatitis (ACD) secondary to acrylates and methacrylates is a well- described occurrence, particularly in those who wear or handle gel nail varnish. Management involves avoidance of the identified allergen. The cause of chronic urticaria (CI) is often not identified, and CU is not known to be associated with acrylates or methacrylates. We report a case of a 50-year-old woman who initially presented with hand dermatitis exacerbated by gel nail varnish on a background of CU. Avoiding all nail varnishes because of her ACD also resulted in improvement of her CU. To our knowledge, this is the first documented case of CU secondary to the acrylates and methacrylates found in nail cosmetics. © 2017 British Association of Dermatologists.

  3. Intramedullary versus extramedullary alignment of the tibial component in the Triathlon knee

    LENUS (Irish Health Repository)

    Cashman, James P

    2011-08-20

    Abstract Background Long term survivorship in total knee arthroplasty is significantly dependant on prosthesis alignment. Our aim was determine which alignment guide was more accurate in positioning of the tibial component in total knee arthroplasty. We also aimed to assess whether there was any difference in short term patient outcome. Method A comparison of intramedullary versus extramedullary alignment jig was performed. Radiological alignment of tibial components and patient outcomes of 103 Triathlon total knee arthroplasties were analysed. Results Use of the intramedullary was found to be significantly more accurate in determining coronal alignment (p = 0.02) while use of the extramedullary jig was found to give more accurate results in sagittal alignment (p = 0.04). There was no significant difference in WOMAC or SF-36 at six months. Conclusion Use of an intramedullary jig is preferable for positioning of the tibial component using this knee system.

  4. Atypical cardioversion in unstable arrhythmia caused by clavicle surgery

    Directory of Open Access Journals (Sweden)

    Stefan Bushuven

    2017-12-01

    Full Text Available We report on a 54-year old male with traumatic brain injury, flail chest and floating shoulder undergoing intramedullary stabilization of a midshaft clavicle fracture in beach chair position. Intraoperatively the patient developed instable atrial fibrillation triggered by implantation of intramedullary nail. Secondary this case shows feasibility of cardioversion in latero-lateral electrode-position due to inaccessible standard positions and patient fixation between the operation table and the X-ray apparatus.

  5. Risk of symptomatic heterotopic ossification following plate osteosynthesis in multiple trauma patients: an analysis in a level-1 trauma centre

    Directory of Open Access Journals (Sweden)

    Pape Hans-Christoph

    2009-10-01

    Full Text Available Abstract Background Symptomatic heterotopic ossification (HO in multiple trauma patients may lead to follow up surgery, furthermore the long-term outcome can be restricted. Knowledge of the effect of surgical treatment on formation of symptomatic heterotopic ossification in polytrauma is sparse. Therefore, we test the effects of surgical treatment (plate osteosynthesis or intramedullary nailing on the formation of heterotopic ossification in the multiple trauma patient. Methods We retrospectively analysed prospectively documented data of blunt multiple trauma patients with long bone fractures which were treated at our level-1 trauma centre between 1997 and 2005. Patients were distributed to 2 groups: Patients treated by intramedullary nails (group IMN or plate osteosynthesis (group PLATE were compared. The expression and extension of symptomatic heterotopic ossifications on 3-6 months follow-up x-rays in antero-posterior (ap and lateral views were classified radiologically and the maximum expansion was measured in millimeter (mm. Additionally, ventilation time, prophylactic medication like indomethacine and incidence and correlation of head injuries were analysed. Results 101 patients were included in our study, 79 men and 22 women. The fractures were treated by intramedullary nails (group IMN n = 50 or plate osteosynthesis (group PLATE n = 51. Significantly higher radiologic ossification classes were detected in group PLATE (2.9 ± 1.3 as compared to IMN (2.2 ± 1.1; p = 0.013. HO size in mm ap and lateral showed a tendency towards larger HOs in the PLATE group. Additionally PLATE group showed a higher rate of articular fractures (63% vs. 28% in IMN while IMN demonstrated a higher rate of diaphyseal fractures (72% vs. 37% in PLATE; p = 0.003. Ventilation time, indomethacine and incidence of head injuries showed no significant difference between groups. Conclusion Fracture care with plate osteosynthesis in polytrauma patients is associated with

  6. Tension Band Plating for Chronic Anterior Tibial Stress Fractures in High-Performance Athletes.

    Science.gov (United States)

    Zbeda, Robert M; Sculco, Peter K; Urch, Ekaterina Y; Lazaro, Lionel E; Borens, Olivier; Williams, Riley J; Lorich, Dean G; Wellman, David S; Helfet, David L

    2015-07-01

    Anterior tibial stress fractures are associated with high rates of delayed union and nonunion, which can be particularly devastating to a professional athlete who requires rapid return to competition. Current surgical treatment strategies include intramedullary nailing, which has satisfactory rates of fracture union but an associated risk of anterior knee pain. Anterior tension band plating is a biomechanically sound alternative treatment for these fractures. Tension band plating of chronic anterior tibial stress fractures leads to rapid healing and return to physical activity and avoids the anterior knee pain associated with intramedullary nailing. Case series; Level of evidence, 4. Between 2001 and 2013, there were 13 chronic anterior tibial stress fractures in 12 professional or collegiate athletes who underwent tension band plating after failing nonoperative management. Patient charts were retrospectively reviewed for demographics, injury history, and surgical details. Radiographs were used to assess time to osseous union. Follow-up notes and phone interviews were used to determine follow-up time, return to training time, and whether the patient was able to return to competition. Cases included 13 stress fractures in 12 patients (9 females, 3 males). Five patients were track-and-field athletes, 4 patients played basketball, 2 patients played volleyball, and 1 was a ballet dancer. Five patients were Division I collegiate athletes and 7 were professional or Olympic athletes. Average age at time of surgery was 23.6 years (range, 20-32 years). Osseous union occurred on average at 9.6 weeks (range, 5.3-16.9 weeks) after surgery. Patients returned to training on average at 11.1 weeks (range, 5.7-20 weeks). Ninety-two percent (12/13) eventually returned to preinjury competition levels. Thirty-eight percent (5/13) underwent removal of hardware for plate prominence. There was no incidence of infection or nonunion. Anterior tension band plating for chronic tibial stress

  7. Celecoxib does not significantly delay bone healing in a rat femoral osteotomy model: a bone histomorphometry study

    Directory of Open Access Journals (Sweden)

    Iwamoto J

    2011-12-01

    Full Text Available Jun Iwamoto1, Azusa Seki2, Yoshihiro Sato3, Hideo Matsumoto11Institute for Integrated Sports Medicine, Keio University School of Medicine, Tokyo, Japan; 2Hamri Co, Ltd, Tokyo, Japan; 3Department of Neurology, Mitate Hospital, Fukuoka, JapanBackground and objective: The objective of the present study was to determine whether celecoxib, a cyclo-oxygenase-2 inhibitor, would delay bone healing in a rat femoral osteotomy model by examining bone histomorphometry parameters.Methods: Twenty-one 6-week-old female Sprague-Dawley rats underwent a unilateral osteotomy of the femoral diaphysis followed by intramedullary wire fixation; the rats were then divided into three groups: the vehicle administration group (control, n = 8, the vitamin K2 administration (menatetrenone 30 mg/kg orally, five times a week group (positive control, n = 5, and the celecoxib administration (4 mg/kg orally, five times a week group (n = 8. After 6 weeks of treatment, the wires were removed, and a bone histomorphometric analysis was performed on the bone tissue inside the callus. The lamellar area relative to the bone area was significantly higher and the total area and woven area relative to the bone area were significantly lower in the vitamin K2 group than in the vehicle group. However, none of the structural parameters, such as the callus and bone area relative to the total area, lamellar and woven areas relative to the bone area, or the formative and resorptive parameters such as osteoclast surface, number of osteoclasts, osteoblast surface, osteoid surface, eroded surface, and bone formation rate per bone surface differed significantly between the vehicle and celecoxib groups.Conclusion: The present study implies that celecoxib may not significantly delay bone healing in a rat femoral osteotomy model based on the results of a bone histomorphometric analysis.Keywords: femoral osteotomy, bone healing, callus, rat, celecoxib

  8. USO DO ENXERTO ÓSSEO CORTICAL BOVINO CONSERVADO EM GLICERINA A 98% NA OSTEOTOMIA FEMORAL EM GATOS USE BOVINE CORTICAL BONE, PRESERVED IN 98% GLICERIN IN FEMORAL OSTEOTOMY IN CATS.

    Directory of Open Access Journals (Sweden)

    Lucia Helena de Carvalho Penha

    2008-12-01

    Full Text Available Enxerto cortical bovino, sob a forma de pino com 4mm de largura e 10cm de comprimento, conservado em glicerina a 98% por trinta dias no mínimo, foi implantado no canal medular de dez gatos e utilizado como único método de fixação, após osteotomia transversa da diáfise femoral esquerda, com o objetivo de avaliar clínica e radiograficamente a eficácia dos xenoenxertos como substitutos aos pinos de metal. Distribuíram-se os animais em dois grupos de cinco gatos, um com gatos jovens com idade inferior a um ano e um grupo de cinco gatos adultos com mais de um ano de idade. Em média, a deambulação normal ocorreu aos quinze dias, com união óssea radiográfica em 16,6 semanas. Dentre os cinco animais do grupo jovem, dois sofreram fratura do enxerto com desvio grave de eixo ósseo, mas sem fratura das corticais femorais e nos três animais restantes o processo de remodelação foi notado em tempo médio de 75 dias. Dos cinco animais do grupo adulto, todos sofreram acavalamento de vários graus, sendo considerado grave em dois animais, por estar associado com fratura das respectivas corticais femorais, mas sem desvio de eixo ósseo. Dos demais animais com acavalamento de grau leve, um apresentou união retardada, um apresentou fratura do enxerto e um apresentou calo ósseo não exuberante, encontrando-se em remodelação aos 110 dias. Pode-se concluir que o método de implantação intramedular de pino ósseo cortical bovino, preservado em glicerina a 98% em gatos jovens e adultos, foi adequadamente empregado, proporcionando suporte mecânico em tempo suficiente para união óssea.

    PALAVRAS-CHAVES: Enxerto cortical bovino, fêmur, fratura, gatos, osteotomia. Cortical xenografts derived from bovine boné and shaped as intramedullary nails, with 4mm of width and 10cm or lenght, preserved in 98% glycerol for a minimum of 30 days were used as the sole method of internal fixation for transverse osteotomy of feline femoral diaphysis

  9. Metachronous brain and intramedullary spinal cord metastases from nonsmall-cell lung cancer: A case report

    Directory of Open Access Journals (Sweden)

    Wen-Chih Liu

    2012-05-01

    Full Text Available A 44-year-old man had a brain tumor secondary to lung adenocarcinoma and underwent craniectomy to remove the brain tumor. After postoperative whole-brain radiation therapy, he underwent pneumonectomy followed by chemotherapy, mediastinal radiotherapy, and target therapy for lung cancer. Thirty-six months after the initial brain surgery, he suffered from neck pain and right upper limb numbness that rapidly progressed to upper extremity weakness and paralysis in 2 months. Magnetic resonance imaging demonstrated an intramedullary spinal cord lesion at the C4 level. Laminectomy and gross intramedullary tumor removal were performed. The patient’s neurological function improved after the operation. Nevertheless, 4 months after the intramedullary tumor removal, he began to show multiple metastases. Unfortunately, the patient died from respiratory failure 8 months after diagnosis with intramedullary spinal cord metastasis. In this case, early diagnosis and aggressive surgical treatment combined with postoperative radiotherapy and chemotherapy might have provided this patient with a prolonged survival and better quality of life.

  10. management of bilateral fracture femur with implant failure

    African Journals Online (AJOL)

    Keywords: Implant failure, nonunion, plating, intramedullary nailing, stress risers, stress shielding. CASE REPORT ... and the patient was thrust forwards, injuring both ... stress once weight bearing starts will be guided by .... J. Bone Joint Surg.

  11. Onychomycosis nailed

    Directory of Open Access Journals (Sweden)

    Leelavathi Muthupalaniappen

    2014-04-01

    Full Text Available Fungal infection of the nail is a common condition that causes much concern because of its disfiguring appearance. Although specific treatment is available for this condition, treatment outcome is variable and persistent nail dystrophy post-treatment may cause distress to both the patient and the physician. This article describes the current available treatment options for onychomycosis, management approach and the expected treatment outcome to enhance primary care physicians’ confidence in managing this condition. Oral antifungal agents such as terbinafine and itraconazole are good treatment options for onychomycosis. Combination therapy using oral antifungal agents with topical lacquer preparations may provide added benefits. Evaluation of patient’s expectations, providing information on treatment outcome, clinical cure and recurrence rates are essential in the management of onychomycosis. This article is intended to guide primary care physicians to achieve realistic treatment goals and for a satisfactory experience in the overall management of this challenging condition.

  12. Correlation of trace metals in hair and nails

    International Nuclear Information System (INIS)

    Benischek-Huber, I.; Benischek, F.

    1985-01-01

    Correlation of Cd, Cu, Hg, Pb and Zn was studied in 350 hair and nail samples of 12 persons. Determination was performed by atomic absorption spectrometry. Cd, Pb and Hg concentrations are fluctuating significantly in the specimens. Correlation was found for these elements in hair and finger nails and for Pb in hair and toe nails. Zn and Cu are more stable, the ratios of contents in corresponding samples are within a small range. (author)

  13. Estimation of arsenic in nail using silver diethyldithiocarbamate method

    Directory of Open Access Journals (Sweden)

    Habiba Akhter Bhuiyan

    2015-08-01

    Full Text Available Spectrophotometric method of arsenic estimation in nails has four steps: a washing of nails, b digestion of nails, c arsenic generation, and finally d reading absorbance using spectrophotometer. Although the method is a cheapest one, widely used and effective, it is time consuming, laborious and need caution while using four acids.

  14. An arachnoid cyst presenting as an intramedullary tumour

    NARCIS (Netherlands)

    Willems, P. W.; van den Bergh, W. M.; Vandertop, W. P.

    2000-01-01

    A case of thoracic intradural extramedullary arachnoid cyst is presented in which an intramedullary low grade glioma was suspected preoperatively. The cyst was widely fenestrated and postoperatively, the patient experienced considerable improvement in her symptoms. As postoperative MRI studies also

  15. Long versus short cephalomedullary nail for trochanteric femur fractures (OTA 31-A1, A2 and A3): a systematic review.

    Science.gov (United States)

    Dunn, John; Kusnezov, Nicholas; Bader, Julia; Waterman, Brian R; Orr, Justin; Belmont, Philip J

    2016-12-01

    Both long and short cephalomedullary nails (CMN) may be used to treat trochanteric femur fractures. The objective of this paper was to compare the clinical outcomes between long and short CMN in the treatment of trochanteric hip fractures. A literature search was performed, identifying 135 papers; 4 of which met inclusion and exclusion criteria. Papers included were those that compared cohorts of long and short nails for stable trochanteric femur fractures of level III evidence or superior. Data was pooled and analyzed, focusing on reoperation rate, secondary femoral shaft fracture rate, estimated blood loss, transfusion rate, operative time and length of stay. Included in the analysis were 1276 patients, with 438 short and 838 long CMN. The average age was 82.0 years for short CMN and 79.0 years for long CMN (P = 0.0002). The average follow up was 18 months, 46 % were male, and 71 % had an ASA (American Society of Anesthesiologists score) classification ≥3. The rate of reoperation was 5.0 % and 3.8 % for short and long CMN, respectively (P = 0.31). The rate of refracture was 1.6 % and 0.95 % for short and long CMN, respectively (P = 0.41). As compared to long nails, short nails had an average blood loss of 39 mL less (P = 0.0003), an 8.8 % decrease in transfusion rate (P = 0.07), and incurred 19 min less operative time (P trochanteric femur fractures, short CMN have a low reoperation rate while significantly decreasing operative time and estimated blood loss with the additional benefit of being cost effective. Level 3.

  16. Download this PDF file

    African Journals Online (AJOL)

    Valued eMachines Customer

    Internal fixation of fractures with implants such as intramedullary nail, Dynamic Compression plate ... good biomechanical environment for healing2. .... Non union was the leading cause of implant failure in this study, accounting for 47.4%.

  17. Preoperative estimation of tibial nail length--because size does matter.

    LENUS (Irish Health Repository)

    Galbraith, J G

    2012-11-01

    Selecting the correct tibial nail length is essential for satisfactory outcomes. Nails that are inserted and are found to be of inappropriate length should be removed. Accurate preoperative nail estimation has the potential to reduce intra-operative errors, operative time and radiation exposure.

  18. Confocal Raman spectrocopy for the analysis of nail polish evidence.

    Science.gov (United States)

    López-López, Maria; Vaz, Joana; García-Ruiz, Carmen

    2015-06-01

    Nail polishes are cosmetic paints that may be susceptible of forensic analysis offering useful information to assist in a crime reconstruction. Although the nail polish appearance could allow a quick visual identification of the sample, this analysis is subjected to the perception and subjective interpretation of the forensic examiner. The chemical analysis of the nail polishes offers great deal of information not subjected to analyst interpretation. Confocal Raman spectroscopy is a well-suited technique for the analysis of paints due to its non-invasive and non-destructive nature and its ability to supply information about the organic and inorganic components of the sample. In this work, 77 regular and gel nail polishes were analyzed with confocal Raman spectroscopy using two laser wavelengths (532 and 780 nm). The sample behavior under the two laser wavelengths and the differences in the spectra taken at different points of the sample were studied for each nail polish. Additionally, the spectra obtained for all the nail polishes were visually compared. The results concluded that the longer laser wavelength prevents sample burning and fluorescence effects; the similarity among the spectra collected within the sample is not directly related with the presence of glitter particles; and 64% of the samples analyzed showed a characteristic spectrum. Additionally, the use of confocal Raman spectroscopy for the forensic analysis of nail polishes evidence in the form of flakes or smudges on different surfaces were studied. The results showed that both types of evidence can be analyzed by the technique. Also, two non-invasive sampling methods for the collection of the evidence from the nails of the suspect or the victim were proposed: (i) to use acetone-soaked cotton swabs to remove the nail varnishes and (ii) to scrape the nail polish from the nail with a blade. Both approaches, each exhibiting advantages and drawbacks in terms of transport and handling were appropriate

  19. Nail Problems (Toenails)

    Science.gov (United States)

    ... may include prescribing topical or oral medication, and debridement (removal of diseased nail matter and debris) of ... treated by your podiatrist, who susceptible to all types of infection, can diagnose the ailment, and then ...

  20. Decision Making in the Management of Extracapsular Fractures of the Proximal Femur - is the Dynamic Hip Screw the Prevailing Gold Standard?

    Science.gov (United States)

    Jacob, Joshua; Desai, Ankit; Trompeter, Alex

    2017-01-01

    Currently, approximately half of all hip fractures are extracapsular, with an incidence as high as 50 in 100,000 in some countries. The common classification systems fail to explain the logistics of fracture classification and whether they all behave in the same manner. The Muller AO classification system is a useful platform to delineate stable and unstable fractures. The Dynamic hip screw (DHS) however, has remained the 'gold standard' implant of choice for application in all extracapsular fractures. The DHS relies on the integrity and strength of the lateral femoral wall as well as the postero-medial fragment. An analysis of several studies indicates significant improvements in design and techniques to ensure a better outcome with intramedullary nails. This article reviews the historical trends that helped to evolve the DHS implant as well as discussing if the surgeon should remain content with this implant. We suggest that the gold standard surgical management of extracapsular fractures can, and should, evolve.